ATE-1509 DATALOGGING LIGHTMETER USER MANUAL www.tmatlantic.com

ATE-1509 DATALOGGING LIGHTMETER USER MANUAL www.tmatlantic.com
DATALOGGING LIGHTMETER
ATE-1509
USER MANUAL
www.tmatlantic.com
INSTRUCTION
¾
The digital illuminance meter is a precision instrument
used to measure illuminance (Lux, footcandle) in the
field.
¾
It is meet CIE photopic spectral response.
¾
It is fully cosine corrected for the angular incidence of
light.
¾
The illuminance meter is compact, tough and easy to
handle owing to its construction.
¾
The light sensitive component used in the meter is a
very stable, long-life silicon photo diode and spectral
response filter.
FEATURES
¾
Light-measuring
levels
ranging
form
0.1Lux~0.1kLux/0.01FC~0.01kFC,repeatedly.
¾
High accuracy and rapid response.
¾
Data-hold function for holding measuring values.
¾
Unit and sign display for easy reading.
¾
Automatic zeroing.
¾
Meter corrected for spectral relative efficiency.
¾
Correction factor need not be manually calculated for
non-standard light sources.
2
¾
Short rise and fall times.
¾
Peak-hold function for tracing the peak signal of light
pulse with least duration 10s and keep it.
¾
Capable of selecting measuring mode in Lux or FC
scale alternatively.
¾
Auto power off 15minutes or disable AUTO power off.
¾
Maximum and minimum measurements.
¾
Relative reading .
¾
Easy to read large backlit display
¾
USB output connect with pc
¾
4 Level ranging
¾
99 values in memory ,that could be read on the meter.
¾
More than 16000 values records datalogger.
SPECIFICATIONS
¾
Display :3-3/4 digit LCD with high speed 40 segment
bar graph.
¾
Measuring Range: x,400.0 Lux,4000 Lux,40.00 KLux
and 400.0 KLux /40.00 FC,400.0 FC,4000 FC,40.00
KFC.
NOTE: 1FC=10.76Lux,1KLux=1000Lux,1KFC=1000FC
¾
Over range Display: LCD will show “OL” symbol.
¾
Spectral Response: CIE Photopic. (CIE human eye
3
response curve).
¾
Spectral Accuracy: CIE V function f1’6%
¾
Cosine Response: f2’ 2%
Accuracy:
±3% rdg±0.5%f.s.(<10,000Lux),
±4% rdg±10d.(>10,000Lux)
¾
Repeatability: ±3%
¾
Sampling Rate: 1.3 times/sec of analog bar-graph
indication;1.3times/sec of digital display.
Datalogger sampling could be setup.
¾
Photo Detector: One silicon photo diode and spectral
response filter.
¾
Operating temperature & Humidity :
0 to 40(32to 104) & 0% to 80% RH.
¾
Storage Temperature & Humidity :
-10 to 50(14 to 140) & 0% to 70% RH.
¾
Power Source: 1 piece 9V battery.
¾
Photo detector Lead Length: 150cm (approx.);
¾
Photo detector Dimensions: 115L×60W×20H(mm);
¾
Meter Dimensions: 170L×80W×40H;
¾
Weight: 390g.
¾
Accessories: Carry case, instruction manual, battery.
NAME OF PARTS AND POSITIONS
4
1.
Power Control key:
The power switch key turns
the illuminance meter ON or OFF.
2.
LCD Display: 3-3/4 digit displays with a maximum
reading of 3999,and the indicating signs of
measured values, unit function symbols and
decimal points etc are display.
5
3.
UNITS key: Pressing this key selects taking
measurement of illuminance in Lux or
FC
scale(1FC =10.76 LUX).
4.
BACK-LIGHT and LOAD control key: Back light
control
5.
and
load the records.
REC and SET key:
memory the values or set
the time , the sampling rate, and Enable the
AUTO power off or ont.
6.
Peak Hold key: Peak Hold recorder control key.
7.
Data-Hold key: Data Hold control key.
8.
RANGE key: change the range. 400.0lux ->
4000lux
->40,000lux
->400,000lux(40.00FC
->400.0FC ->4000FC ->40,000FC).
9.
MAX/MIN key: Maximum and minimum reading
recorder control key.
10. REL key: Relative reading control key.
OPERATING INSTRUCTIONS
1.
Power-up: Press the power key to turn the meter ON or
2.
Selecting the Lux or FC scale: Set the range selection
OFF.
switch to desired Lux or FC range.
6
3.
Remove the photo detector cap and face it light source
in a horizontal position.
4.
Press
the REC/SET key and RANGE/APO key,
Enable the AUTO power off or Disable this function.
5.
Read the illuminance nominal from the LCD display.
6.
Over range: If the instrument only displays “OL”, the
input signal is too strong, and a higher range should be
selected. The range will show on the down of the LCD,
LUX :400 -> 4K -> 40k -> 400k; FC: 40 -> 400-> 4k ->
40k.
7.
Data-Hold mode: Press the hold key to select Data-Hold
mode. When HOLD mode is selected, the illuminance
meter stops all further measurements. Press the HOLD
key again to exit Data-Hold mode. Then it resumes
normal operation.
8.
Peak-Hold
mode: Press the PEAK key
to choose
Pmax or Pmin recorder mode, and expose the photo
detector to light pulse measuring field. Press the PEAK
key again to exit PEAK recorder mode, then the meter
will resume normal operation.
9.
Maximum and Minimum mode: Press MAX/MIN key to
choose the Maximum (MAX) reading, Minimum (MIN)
reading and current reading (MAX/MIN blink) recorder
7
mode. Press MAX/MIN key again to exit this mode.
10. Relative reading mode: Press REL key to enter Relative
mode. The display shown zero value and the current
reading will be stored as a zero-in value. Press again to
exit this mode.
11. USB mode: connect with pc with USB ,the “
” will
displays in the screen.
12. Back-light function: Press the Backlight key to turn
on. Press again to turn off.
13. When the measurement is completed, replace the photo
detector cap and turn the meter off.
14. Setup time and sampling rate:
Press the MEM/SETUP and UNITS key
start
to
setup the time and sampling . The first setup target is
The hour
Press key”PEAK or REL “ to choose the object of the
setting
Press “REL” key to choose object to repeat as below
process: Hour->minter->second-> sampling-> month ->
day ->week -> year ->hour …….
Press PEAK key to choose the object and repeat as
below process:
8
Hour ->year ->week -> day -> month ->sampling
->second ->minter ->hour -.>year ……..
Press MAX/MIN key to add object of setting
Press HOLD key to reduce the object of seting
Hold key of MEM/SETUP and UNITS to exit the setting
time and sampling mode, and then confirm .
15. MEM function:
Press key of MEM/SET to save the present data.
HOLD key of LOAD 5s start to load the records
Press key of MAX/MIN to add the number of records.
Press key of HOLD to reduce the number of records.
After you do that you must hold the key of LOAD 5s to
resume normal operation .
16. DATALOGGER function:
SETUP the time and sampling rate first, the default
sampling rate is 1s.
Hold the key of MEM/SETUP 5s, start the datalogger
function, the MEM on the screen will be bicker. If the
memory IC is full ,the memory number will show ‘OL’.
Press the key of MEM/SETUP 5s , stop the datalogger
function , then the meter will resume normal operation.
Then the datalogger number will return to 1, you could
start your records again.
9
17. HOLD the key of MEM/SETUP and LOAD 5s to clear
the 99 memory .
BATTERY CHECK-UP & REPLACEMENT
1.
As the battery power is not sufficient, LCD will display
low battery, and replacement of one new battery is
required.
2.
After turning off the meter, disconnect the battery cover
3.
Disconnect the battery from the instrument and replace
with a screwier.
it with a standard 9V battery and go for the cover.
SPECTRAL SENSITIVITY CHARACTERISTIC
¾
To the detector, the applied photo diode with filters
makes
almost
the
spectral
meet
COMMISSION
ON
sensitivity
characteristic
C.I.E.(INTERNATIONAL
ILLUMINATION)
curve V () as the following chart described.
10
Photo
MAINTENANCE
1.
The white plastic disc on the top of the detector should
be cleaned with a damp cloth when necessary.
2.
Do not store the instrument where temperature or
3.
The reference level, as marker on the face plate, is the
humidity is excessively high.
tip of the photo detector globe.
4.
The calibration interval for the photo detector will vary
according to operational conditions, but generally the
sensitivity decreases in direct proportion to the product
of luminous intensity by the operational time. In order to
maintain the basic accuracy of the instrument, periodic
calibration is recommended.
RECOMMENDED ILLUMINATION
1FC=10.76Lux
11
LOCATIONS
OFFICE
Lux
FC
200~750
18~70
Clerical work
700~1,500
65~140
Typing drafting
1,000~2,000
93~186
Visual work at
300~750
28~70
Inspection work
750~1,500
70~140
Electronic parts
1,500~3,000
140~279
150~300
14~28
100~200
9~18
Reception
200~500
18~47
Cashier
750~1,000
70~93
Indoors Stairs
150~200
14~18
750~1,500
70~140
1,500~3,000
140~279
Conference,
Reception room
FACTORY
production line
assembly line
Packing work,
Entrance passage
HOTEL
Public room,
Cloakroom
STORE
Corridor
Show window,
Packing table
Forefront of show
window
12
HOSPITAL
Sickroom,
100~200
9~18
300~750
28~70
750~1,500
70~140
100~300
9~28
Class room
200~750
18~70
Laboratory, Library,
500~1,500
47~140
Warehouse
Medical Examination
Room
Operating room,
emergency
treatment
SCHOOL
Auditorium, Indoor
Gymnasium
Drafting, room
Connecting to pc
System requirements:
Windows 98 or windows 2000 (or higher)
Minimum hardware requirements
Pc or notebook, 90MHz Pentium of faster, 32Mb
Ram,
At least 5Mb free hard disk space screen resolution
800×600.
Connection
1, Switch the light meter on
2, Plug the other end of the connecting cable to
13
serial interface of the PC (USB).
3, Plug the USB line connecting cable 13.6mm jack
plug into the meter socket
5, Start the light meter software.
6, Selecting the COM port 3. note select the 4 COM.
(Note: you should better switch the light meter on
before you plug the USB line connecting cable
13.6mm jack plug into the meter)
Installing the software
z Stare windows
z Close any applications possibly open before
installing the “CEM.LINK” software.
z Insert the CD into the CD-drive.
z Enter x:\setup in the command line and press
OK.
The files setup.exe and the help file will be
copied onto the hard disk (selected path:
c:\program files\ Lightmeter). x is the
drive-letter of your CD-drive ,e.g. ”g”.
z Now follow the installation program
instructions.
z Once the software is installed, switch on
14
z
the meter.
z Start the software.
z Selected the COM port 3. note is 4.
z If the connection is in order, the following
display will be seen on the screen.
If the connection is not in order, the message
“NO CONNECTION” appears on the screen.
15
Was this manual useful for you? yes no
Thank you for your participation!