- No category
advertisement
Gaseous Product Line
GM60-02
60 kWe
Ratings
Phase
PF
Hz
Generator Model
Connection
Standby kWe Nat (LP)
AMPS Nat (LP)
Temp Rise
240V
1
1.0
60
362CSL1604
12 LEAD ZIG-ZAG
60 (60)
250 (250)
130˚C / 27˚C
208V
3
0.8
60
361CSL1602
12 LEAD WYE
60 (60)
208 (208)
130˚C / 27˚C
208-600 Volt
60 Hz / 1800 RPM
Standby
240V
3
0.8
60
361CSL1602
12 LEAD DELTA
60 (60)
181 (181)
130˚C / 27˚C
480V
3
0.8
60
361CSL1601
12 LEAD WYE
60 (60)
90 (90)
130˚C / 27˚C
600V
3
0.8
60
361PSL1633
4 LEAD WYE
60 (60)
72 (72)
130˚C / 27˚C
Standard Equipment
Engine
Radiator Cooled Unit Mounted (50˚C)
Blower Fan & Fan Drive
Starter & Alternator
Oil Pump & Filter
Oil Drain Extension w/Valve
Governor - Electronic Isochronous
12V Battery System & Cables
Air Cleaner (Dry Single Stage)
Flexible Fuel Connector
EPA Certified
Listing Certifications
UL 2200 Listed
cUL Listed
CSA Certified
Seismic Certified to IBC 2012
Generator
Brushless Single Bearing
Automatic Voltage Regulator
± 1% Voltage Regulation
4 Pole, Rotating Field
130˚C Standby Temperature Rise
100% of Rated Load - One Step
5% Maximum Harmonic Content
NEMA MG 1, IEEE and ANSI Standards
Compliance for Temperature Rise
Additional
Microprocessor Based Digital Control
Interface Connection Box
Control Panel Mounted in NEMA 12 Enclosure
Base - Formed Steel
Main Line Circuit Breaker Mounted & Wired
Critical Grade Silencer Mounted
Battery Charger 12V 6 Amp
Jacket Water Heater -20˚F 1500W 120V w/Isolation Valves
Vibration Isolation Mounts
Radiator Duct Flange (OPU Only)
Single Source Supplier
2YR / 2000HR Standby Warranty
Standard Colors - White / Tan / Gray
GM60-02
Gaseous Product Line
60 kWe
Application Data
Engine
Manufacturer: General Motors
Model: GM 5.7L EPA
Type: 4-Cycle
Aspiration: Natural
Cylinder Arrangement: 8 Cylinder Vee
Displacement - Cu. In. (lit):
Bore - in. (cm) x Stroke - in. (cm):
Compression Ratio:
Rated RPM:
Max HP Stby (kWm):
350 (5.70)
4.00 (10.2) x 3.5 (8.80)
9.40:1
1800
113 (78.1)
Exhaust System
Gas Temp. (Stack): °F (°C)
Gas Volume at Stack Temp: CFM (m³/min)
Maximum Allowable Exhaust Restriction: in. H
2
O (kPa)
Cooling System
Ambient Capacity of Radiator: °F (°C)
Maximum Allowable Static Pressure on Rad. Exhaust: in. H
2
O (kPa)
Water Pump Flow Rate: GPM (lit/min)
Heat Rejection to Coolant: BTUM (kW)
Heat Rejection to CAC: BTUM (kW)
Heat Radiated to Ambient: BTUM (kW)
Air Requirements
Aspirating: CFM (m³/min)
Air Flow Required for Rad. Cooled Unit: CFM (m³/min)
Air Flow Required for Heat Exchanger/Rem. Rad. CFM (m³/min)
Fuel Consumption
At 100% of Power Rating: ft3/hr (m3/hr)
At 75% of Power Rating: ft3/hr (m3/hr)
At 50% of Power Rating: ft3/hr (m3/hr)
Fuel Inlet Size: NPT
Fuel Pressure Required: in. H20 (kPa)
Fluids Capacity
Total Oil System: gal (lit)
Engine Jacket Water Capacity: gal (lit)
System Coolant Capacity: gal (lit)
All calculations based on natural gas fuel.
Deration Factors: Temperature: Derate 1% Per 10 o F Over 77 o F Air Inlet Temperature | Altitude: Derate 3% Per 1,000 ft Over 328 ft
GM60-02
173 (4.90)
7,400 (209)
Consult Factory For Remote Cooled Applications
Natural Gas
859 (24.3)
725 (20.5)
LP
363 (10.3)
305 (8.63)
578 (16.4) 244 (6.91)
1.00”
7.00 - 11.0 (1.75 - 2.75)
1.25 (4.73)
2.03 (7.68)
6.00 (22.7)
Standby
1,350 (732)
553 (15.7)
40.8 (10.2)
122 (50.0)
0.50 (0.12)
36.6 (139)
3,120 (54.6)
N/A
854 (14.9)
Gaseous Product Line
60 kWe
DGC-2020 Control Panel
Standard Features
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
CAN Bus ECU Communications
Windows-Based Software
Multilingual Capability
Remote Communications to RDP-110 Remote Annunciator
16 Programmable Contact Inputs
Up to 15 Contact Outputs (7 standard)
UL Recognized, CSA Certified, CE Approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
NFPA 110 Level 1 Compatible
Weights / Dimensions / Sound Data
L x W x H Weight lbs
OPU
80 x 38 x 52 in 1,675
Level 1
90 x 38 x 60 in 2,150
Level 2
90 x 38 x 60 in 2,175
Level 3
120 x 38 x 60 in 2,325
Please allow 6-12 inches for height of exhaust stack.
OPU
Level 1
Level 2
Level 3
No Load
76 dBA
71 dBA
66 dBA
63 dBA
Full Load
79 dBA
73 dBA
68 dBA
64 dBA
Drawings based on standard open power 480 volt standby generator. Lengths may vary with other voltages. Subject to change without notice.
Sound data as measured at 23 feet (7 meters) in accordance with ISO 8528-10 at standby rating.
GM60-02
Gaseous Product Line
60 kWe
Enclosures
All enclosures are 150 MPH Wind Rated.
Level 2 & 3 enclosures include sound attenuation foam.
Level 3 enclosure includes frontal sound & exhaust hood.
*Enclosure height does not include exhaust stack.
All specification sheet dimensions are represented in inches.
Materials and specifications subject to change without notice.
Distributed By:
GM60-02
Blue Star Power Systems, Inc.
52146 Ember Road
Lake Crystal, Minnesota 56055
Phone + 1 507 726 2508 bluestarps.com
quote.bluestarps.com
4 of 4
advertisement