250-0289 rev1.qxd 3/9/01 10:45 AM Page a

USER’S MANUAL

MMVFD Series

Models:

MMVFD03-115AC

MMVFD04-115AC

MMVFD03-230AC

MMVFD04-230AC

MMVFD03-D230AC

MMVFD04-D230AC

Variable-frequency drives for

3-phase AC motors

250-0289 rev1.qxd 3/9/01 10:45 AM Page b

Copyright

2001 by

Minarik Corporation

All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Corporation. The information and technical data in this manual are subject to change without notice. Minarik

Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to keep current the information in this manual.

Printed in the United States of America.

250-0289 rev1.qxd 3/9/01 10:45 AM Page i

Safety Warnings

This symbol denotes an important safety tip or warning.

Please read these instructions carefully before performing any of the procedures contained in this manual.

DO NOT INSTALL, REMOVE, OR REWIRE THIS

EQUIPMENT WITH POWER APPLIED. Have a qualified electrical technician install, adjust and service this equipment.

Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the

Occupational Safety and Health Act (OSHA), when installing equipment.

Reduce the chance of an electrical fire, shock, or explosion by proper grounding, over-current protection, thermal protection, and enclosure. Follow sound maintenance procedures.

It is possible for a drive to run at full speed as a result of

a component failure. Minarik strongly recommends the installation of a master switch in the main power input to stop the drive in an emergency.

Circuit potentials are at 115 VAC or 230 VAC above earth ground. Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic screwdriver for adjusting the calibration trimpots. Use approved personal protective equipment and insulated tools if working on this drive with power applied.

i

250-0289 rev1.qxd 3/9/01 10:45 AM Page ii ii

General Information

The Minarik MotorMaster Variable Frequency Drive (MMVFD)

Series are solid-state, ASIC-based, variable-frequency AC motor drives. With a 115 or 230 VAC, 50/60 Hz, single-phase input,

MMVFDs are factory calibrated for an output of 1* to 60 Hz.

They will operate any 1 HP or smaller, 115- or 208/230-volt, three-phase-AC-induction, single-phase or permanent split capacitor motor through a speed range of zero* through nameplate speed. They can be user calibrated for 1* through 120

Hz output.

Although MMVFD inverters can operate over a 30:1 speed range, most motors will operate over a 10:1 speed range with constant torque at 1* to 60 Hz and constant horsepower above 60 Hz.

(Inverter-duty motors may operate satisfactorily over a 20:1 speed range.) Some motors can be satisfactorily operated at speeds as low as 50 rpm (speed range 50:1). Below 50 rpm, some motors may show signs of “stepping” or “cogging”, or run warmer.

*Although the MMVFD will allow a minimum of 1 Hz, the actual minimum frequency is dependent on motor type and load. The motor may need to be derated for low-frequency (30 Hz and lower) operation. Please consult the motor manufacturer.

250-0289 rev1.qxd 3/9/01 10:45 AM Page iii

General Information iii

Many 3-phase inverter manufacturers claim that they can run single-phase motors effectively. This is normally accomplished by wiring only 2 phases; however, this primitive method may cause instabilities due to the lack of feedback from one of the motor connections. Furthermore, motor torque will be reduced considerably because the phases are still 120º apart. The

MMVFD can efficiently operate a single-phase motor because the

ASIC changes the phase shift to 180º in order to develop maximum torque.

A 90º phase-shifted output is provided in two-phase operation in order to eliminate the start capacitor.

The MMVFD series features solid-state reversing with adjustable acceleration and deceleration. The MMVFD may also interface with motor thermal protection through the enable circuit.

250-0289 rev1.qxd 3/9/01 10:45 AM Page iv iv

General Information

MMVFD Series Features

• ASIC-based

• Solid-state circuitry

• Adjustable minimum and maximum speed

• Adjustable acceleration and deceleration

• Solid-state braking and reversing

• Adjustable current limit

• Adjustable V/Hz during acceleration

• Adjustable voltage boost at low speeds

• Multiple motor operation

• Three-phase and single-phase motor control

• Power LED

• Current limit LED (“D” versions only)

• DC injection braking

250-0289 rev1.qxd 3/9/01 10:45 AM Page v

General Information

IMPORTANT INFORMATION

Caution should be taken when operating fan-cooled motors at low speeds because their fans may not move sufficient air to properly cool the motor. Minarik recommends “inverterduty” motors when the speed range is beyond 10:1.

In addition to standard 3-phase induction motors, the following motor types may be used with the MMVFD:

• Permanent split capacitor (PSC)

• Shaded pole

• AC synchronous

• AC stepping: 28.8, 72 and 200-RPM type.

v

The following motor types MAY NOT be used:

• Split phase

• Capacitor start

• Repulsion induction

• Series Universal AC/DC

• Any motor with starting switch (centrifugal or relay) and/or separate starting winding.

250-0289 rev1.qxd 3/9/01 10:45 AM Page vi vi

Contents

Specifications

Dimensions

Installation 5

Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Shielding guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Heat sinking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Fusing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Speed adjust potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Cage-clamp terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Power and fuse connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Motor connections (all MMVFD-series controls)

Signal and Optional Switch Connections

. . . . . . . . . . . . . . . . . . . .15

. . . . . . . . . . . . . . . . . . . . . . . . .20

Operation 22

Jumper Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Drive phase output (JMP501 and JMP502)

Acceleration mode select (JMP503)

. . . . . . . . . . . . . . . . . . . . . . .23

. . . . . . . . . . . . . . . . . . . . . . . . . . . .24

Braking mode select (JMP504) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Voltage doubler output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

To reverse motor direction: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Starting and stopping methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

Calibration 34

Calibration Procedure Setup for 60 Hz Motors: . . . . . . . . . . . . . . . . . . . . . . .37

Application Notes

Decelerate to minimum speed

41

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

Independent adjustable speeds with

DIR switch

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

1

2

250-0289 rev1.qxd 3/9/01 10:45 AM Page vii

Contents vii

RUN/JOG switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43

Single speed potentiometer control of multiple motors . . . . . . . . . . . . . . . . . .44

Troubleshooting 45

Before troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52

Index

Unconditional Warranty

54 inside back cover

250-0289 rev1.qxd 3/9/01 10:45 AM Page viii viii

Illustrations

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

MMVFDxx-115AC and MMVFDxx-230AC Dimensions . . . . . . . . . . . .2

MMVFDxx-D230AC Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Heat Sink Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Speed Adjust Potentiometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Cage-Clamp Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

AC Line and Fuse Connections for MMVFDxx-115AC and MMVFDxx-230AC Series Drives . . . . . . . .12

AC Line and Fuse Connections for Figure 8.

Figure 7.

MMVFDxx-D230AC Series Drives (No Voltage Doubler) . . . . . . . . . .14

AC Line and Fuse Connections for

MMVFDxx-D230AC Series Drives (Voltage Doubler Mode) . . . . . . . .14

Motor Connections for Single-Phase Operation Figure 9.

(Motor With Pre-Wired Capacitor) . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Figure 10. Motor Connections for Two-Phase Operation

(No Pre-Wired Capacitor) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

Figure 11. Motor Connections for Three-Phase Motors . . . . . . . . . . . . . . . . . . .19

Figure 12. Signal and Optional Switch Connections . . . . . . . . . . . . . . . . . . . . . .21

Figure 13. MMVFDxx-D230AC Acceleration Personality . . . . . . . . . . . . . . . . . .26

Figure 14. MMVFDxx-D230AC Braking Personality . . . . . . . . . . . . . . . . . . . . . .26

Figure 15. Jumper Terminal Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

Figure 16. Jumper Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Figure 17. Thermal Overload Switch with Optional Enable/Disable Switch . . . .33

Figure 18. MMVFDxx-D230AC Calibration Trimpot Layout . . . . . . . . . . . . . . . .35

Figure 19. MMVFDxx-115AC and MMVFDxx-230AC Calibration Trimpot Layout 36

Figure 20. Run/Decelerate to Minimum Speed Switch . . . . . . . . . . . . . . . . . . . .41

Figure 21. Independent Adjustable Speeds . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

Figure 22. RUN/JOG Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43

Figure 23. Single Speed Potentiometer Control of Multiple Motors . . . . . . . . . . .44

Figure 24. Diagnostic LED location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47

250-0289 rev1.qxd 3/9/01 10:45 AM Page ix ix

Tables

Table 1.

Table 2.

Table 3.

Line Fusing Chart

Jumper Settings

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52

250-0289 rev1.qxd 3/9/01 10:45 AM Page x

Notes

250-0289 rev1.qxd 3/9/01 10:45 AM Page 1

Specifications

Drive

MMVFD03-115AC

MMVFD03-D230AC*

MMVFD03-230AC

MMVFD04-115AC

MMVFD04-D230AC*

MMVFD04-230AC

1-Phase

Input

(VAC)

115

115/230

230

115

115/230

230

1 or 3-Phase

Output

(VAC)

115

230

230

115

230

230

Max

HP

¼

½

½

½

1

1

Max Continuous AC

Output

Current (AC)

2.4

2.4

2.4

4.0†

4.0†

4.0†

Amps

In

7

11/7

7

10

16/10

10

*Connect only 115 VAC line input to the 115 VAC terminals. Do not connect 230 VAC line input to the 115 VAC terminals. This will result in severe damage to the motor and drive, and possible explosion and injury.

† Requires Minarik heat sink kit p/n 223-0159 when continuous current is greater than 3 amps or if ambient temperature is above 40º C. Derate current by 2% per degree if the operating temperature is above 40º C. Under no circumstances may the ambient temperature exceed 55º C.

AC Voltage Input Range

MMVFDxx-115AC drives

MMVFDxx-230AC drives

MMVFDxx-D230AC drives

Fundamental Carrier Frequency

Output Frequency Range

Adjustable Minimum Output Frequency Range

Maximum Output Frequency Range (60 Hz input)

Acceleration Time Range (no load)

115 VAC ± 10%, 50/60 Hz single phase

230 VAC ± 10%, 50/60 Hz single phase

115/230 VAC ± 10%, 50/60 Hz single phase

15 KHz

1 – 120 Hz

1** – 11 Hz

40 – 120 Hz

2 seconds

Deceleration Time Range (no load)

Analog Input Voltage Range (signal must be isolated; S1 [-] to S2 [+])

Input Impedance, S1 to S2

Vibration

2 seconds

0 – 5VDC

~ 50K ohms

0.5G max (20 – 50 Hz)

Weight

Ambient Operating Temperature Range

0.1G max (>50 Hz)

1.2 lb

10º – 40º C

**The actual minimum frequency you observe is dependent on your motor and system setup.

1

250-0289 rev1.qxd 3/9/01 10:45 AM Page 2

2

Dimensions

ALL DIMENSIONS IN INCHES [MILLIMETERS]

DRIVE

MMVFD03-115AC

MMVFD04-115AC

MMVFD03-230AC

MMVFD04-230AC

DIM. “H”

2.15 [55]

2.54 [65]

2.34 [60]

2.50 [68]

Figure 1. MMVFDxx-115AC and MMVFDxx-230AC Dimensions

250-0289 rev1.qxd 3/9/01 10:45 AM Page 3

Dimensions

3

DRIVE

MMVFD03-D230AC

MMVFD04-D230AC

DIM. “H”

2.30 [59]

2.50 [64]

ALL DIMENSIONS IN INCHES [MILLIMETERS]

Figure 2. MMVFDxx-D230AC Dimensions

250-0289 rev1.qxd 3/9/01 10:45 AM Page 4

4

Dimensions

ALL DIMENSIONS IN INCHES [MILLIMETERS]

Figure 3. Heat Sink Dimensions

250-0289 rev1.qxd 3/9/01 10:45 AM Page 5

Installation

Mounting

Warning

Do not install, rewire, or remove this control with input

power applied. Doing so may cause fire or serious injury.

Make sure you have read and understood the Safety

Warnings before attempting installation.

NOTE:

Horizontal mounting may require derating the drive.

See your Minarik representative for more information.

• Mount the drive in either a vertical plane (recommended) or the horizontal plane. Six 0.19-inch (5 mm) wide slots accept #8 pan head screw. Fasten either the large base or narrow flange of the chassis to the subplate.

• Drive components are sensitive to electrostatic fields. Avoid direct contact with the circuit board. Hold drive by the chassis only.

• Protect the drive from dirt, moisture, and accidental contact.

Provide sufficient room for access to the terminal block and calibration trimpots.

• Mount the drive away from heat sources. Operate the drive within the specified ambient operating temperature range.

• Prevent loose connections by avoiding excessive vibration of the drive.

• The chassis must be earth grounded. Use a star washer beneath the head of at least one of the mounting screws to penetrate the anodized chassis surface and to reach bare metal.

5

250-0289 rev1.qxd 3/9/01 10:45 AM Page 6

6

Installation

Wiring

Warning

Do not install, remove, or rewire this equipment with power applied. Failure to heed this warning may result in fire, explosion, or serious injury.

Circuit potentials are at 115 or 230 VAC above ground. To prevent the risk of injury or fatality, avoid direct contact with the printed circuit board or with circuit elements.

Do not disconnect any of the motor leads from the drive unless power is removed. Opening any one motor lead may destroy the drive.

• Use 20 – 24 AWG wire for speed adjust potentiometer wiring.

Use 14 – 16 AWG wire for AC line (L1, L2) and motor (U,V and W) wiring.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 7

Installation

Shielding guidelines

Warning

Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls.

As a general rule, Minarik recommends shielding of all conductors.

7

If it is not practical to shield power conductors, Minarik recommends shielding all logic-level leads. If shielding the logic leads is not practical, the user should twist all logic leads with themselves to minimize induced noise.

It may be necessary to earth ground the shielded cable. If noise is produced by devices other than the drive, ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield.

If the drive continues to pick up noise after grounding the shield, it may be necessary to add AC line filtering devices, or to mount the drive in a less noisy environment.

Logic wires from other input devices, such as motion controllers and PLL velocity controllers, must be separated from power lines in the same manner as the logic I/O on this drive.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 8

8

Installation

Heat sinking

MMVFD04-series drives require heat sink p/n 223-0159 when the continuous armature current is above 3 amps AC. All other

MMVFD series drives have sufficient heat sinking in their basic configurations. No additional heat sinking is necessary.

Fusing

MMVFD series drives require external AC power line fuses.

Connect the external line fuse(s) in series with the AC voltage input. See Connections on page 11. Use fast-acting fuses rated for 250 VAC or higher. See Table 1 for recommended line fuse sizes.

Table 1. Line Fusing Chart

1-Phase

Drive

MMVFD03-115AC

Input

(VAC)

115

MMVFD03-D230AC 115/230

MMVFD03-230AC

MMVFD04-115AC

230

115

MMVFD04-D230AC 115/230

MMVFD04-230AC 230

1

1

½

½

Max

HP

¼

½

AC

Amps

In

10

AC Line

Fuse

Size (Amps)

15

11/7

7

10

16/10

10

20/15

15

15

25/15

15

250-0289 rev1.qxd 3/9/01 10:45 AM Page 9

Installation

Speed adjust potentiometer

Warning

Be sure that the potentiometer tabs do not make contact with the potentiometer enclosure. Grounding the input will cause damage to the drive.

Mount the speed adjust potentiometer through a 0.38 in. (10 mm) hole with the hardware provided (Figure 4). Install the circular insulating disk between the panel and the 10K ohm speed adjust potentiometer. Twist the speed adjust potentiometer wire to avoid picking up unwanted electrical noise. If speed adjust potentiometer wires are longer than 18 in. (457 mm), use shielded cable. Keep speed adjust potentiometer wires separate from power leads (L1, L2, U, V, W).

9

Figure 4. Speed Adjust Potentiometer

250-0289 rev1.qxd 3/9/01 10:45 AM Page 10

10

Installation

Cage-clamp terminals

MMVFD Series connections include cage-clamp terminals (see

Figure 5). To insert a 20 AWG or smaller wire into a terminal:

1. Press down on the lever arm using a small screwdriver.

2. Insert wire into the wire clamp.

3. Release the lever arm to clamp wire.

Side view of wire installation

Figure 5. Cage-Clamp Terminal

250-0289 rev1.qxd 3/9/01 10:45 AM Page 11

Installation

Connections

Warning

Do not connect this equipment with power applied.

Failure to heed this directive may result in fire or serious injury.

Minarik strongly recommends the installation of a master

power switch in the voltage input line. The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts.

Power and fuse connections

11

MMVFDxx-115AC and MMVFDxx-230AC series

Connect the AC power input to L1 and L2 as shown in Figure 6

(page 12).

Connect an external fuse between the drive and master stop switch. Install the switch between the external fuse and AC power input as shown.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 12

12

Installation

Figure 6. AC Line and Fuse Connections for MMVFDxx-115AC and MMVFDxx-230AC Series Drives

250-0289 rev1.qxd 3/9/01 10:45 AM Page 13

Installation

MMVFDxx-D230AC series

Warning

Do not connect 230 VAC line input to the 115 VAC terminals.

This will result in severe damage to the motor and drive, possible explosion and severe injury.

13

Connect AC power input to L1 and L2 as shown in Figure 7 or

Figure 8 (page 14), depending on your power needs.

NOTE:

MMVFDxx-D230AC-series drives are equipped with a voltage-doubling feature, which converts a 115 VAC input to a

230 VAC output, for use with 230V motors. The drive current output remains the same. Use caution when connecting this output.

• If the input voltage is 115 VAC and the desired output voltage is 230 VAC (voltage doubler mode), connect L1 and L2/120 as shown in Figure 7. Do not add a line fuse to L2.

• If the input voltage is 115 VAC and the desired output voltage is 115 VAC (no voltage doubler), connect L1 and L2/240 as shown in Figure 8. Do not add a line fuse to L2.

• If the input voltage is 230 VAC and the desired output voltage is 230 VAC (no voltage doubler), connect L1 and L2/240 as shown in Figure 8. Add a line fuse to L1 and L2/240. Do

not use the voltage doubler with 230 VAC line voltage.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 14

14

Installation

WARNING: DO NOT

CONNECT 230 VAC TO

115 VAC TERMINALS

Figure 7. AC Line and Fuse Connections for

MMVFDxx-D230AC Series Drives (Voltage Doubler Mode)

Figure 8. AC Line and Fuse Connections for

MMVFDxx-D230AC Series Drives (No Voltage Doubler)

250-0289 rev1.qxd 3/9/01 10:45 AM Page 15

Installation

Motor connections (all MMVFD-series controls)

Single-phase operation

15

Warning

It is very important that terminal V, the center motor terminal on the circuit board, be left open (no connection) for single-phase operation.

NOTE:

If the motor and capacitor are sold separately,

Minarik highly recommends buying only the motor and operating in 2-phase mode as described below. The resulting speed range will be considerably wider, while starting torque will approach that of a 3-phase motor.

If the motor capacitor is permanently mounted to the motor by the factory, Minarik recommends leaving the capacitor attached (thereby reducing the potential for human error) and running the drive and motor in single-phase mode.

NOTE:

Ensure that jumper terminals JMP501 and JMP502 are properly set before applying power to the motor and drive. Refer to Jumper Settings (page 23) for more information.

For single-phase operation, connect the motor as shown in Figure

9 (page 16). Ensure that the prewired capacitor and its associated motor coil are connected to terminals U and W as shown. This connection may be internal if using a 2-wire motor. If the motor has three leads, you must make this connection yourself. Make no connection to terminal V.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 16

16

Installation

NOTE: MAKE NO

CONNECTION TO

TERMINAL “V”

Figure 9. Motor Connections for Single-Phase Operation

(Motor With Pre-Wired Capacitor)

250-0289 rev1.qxd 3/9/01 10:45 AM Page 17

Installation

Two-phase operation

Warning

For two-phase operation, ensure that the start capacitor is not connected.

NOTE:

Ensure that jumper terminals JMP501 and JMP502 are properly set before applying power to the motor and drive. Refer to Jumper Settings (page 23) for more information.

17

Connect the motor as shown in Figure 10 (page 18). Ensure that terminals U and V are connected through the motor coil as shown. In a three-wire motor, this connection may be internal. If the motor has four leads, you must make this connection yourself.

Make no connection between terminals V and W.

Three-phase operation

NOTE:

Ensure that jumper terminals JMP501 and JMP502 are properly set before applying power to the motor and drive. Refer to Jumper Settings (page 23) for more information.

Connect a three-phase motor to terminals U, V and W as shown in Figure 11 (page 19).

250-0289 rev1.qxd 3/9/01 10:45 AM Page 18

18

Installation

Figure 10. Motor Connections for Two-Phase Operation

(No Pre-Wired Capacitor)

250-0289 rev1.qxd 3/9/01 10:45 AM Page 19

Installation

19

Figure 11. Motor Connections for Three-Phase Motors

250-0289 rev1.qxd 3/9/01 10:45 AM Page 20

20

Installation

Signal and Optional Switch Connections

Make all signal and switch connections at TB501 as shown in

Figure 12. TB501 is located on the upper board on MMVFDxx-

D230AC-series drives. Terminal board orientation and terminal names are identical for all MMVFD03 and -04 series drives.Use

20-24 AWG wire for speed adjust pot and switch connections.

Speed adjust potentiometer

Connect a speed adjust potentiometer to terminals S1, S2 and S3.

Make sure the potentiometer is connected so that the motor speed will increase as the wiper (S2) is turned clockwise (CW).

ENABLE/DISABLE switch

Connect a single-pole, single-throw ENABLE/DISABLE switch between the ENABLE (EN) and COM terminals as shown. Open the switch to disable the drive and coast to a stop. Close the switch to accelerate to set speed at a rate controlled by the

ACCEL trimpot.

DIRECTION (DIR) switch

Connect a single-pole, single-throw DIR switch between the DIR and COM terminals as shown. Opening the switch will cause the motor to rotate in the forward direction; closing the switch will reverse motor rotation.

The drive will decelerate the motor to a stop before reversing, so there is no need to wait for the motor to coast to a stop before changing direction.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 21

Installation

21

ENABLE (EN)

DIR

TB501

TERMINAL

ASSIGNMENTS

COM

S1

S2

S3

Figure 12. Signal and Optional Switch Connections

250-0289 rev1.qxd 3/9/01 10:45 AM Page 22

22

Operation

Warning

Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the

motor stops. BE ALERT. High voltages can cause serious or fatal injury.

Do not change jumper settings with power applied.

Ensure that jumper settings are compatible with the motor being controlled.

VOLTAGE INPUT WARNING FOR

MMVFDxx-D230AC DRIVES

Do not connect 230 VAC line input to the 115 VAC terminals. This will result in severe damage to the motor and drive, and possible explosion and injury.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 23

Operation

23

Jumper Settings

Warning

Do not change jumper settings with power applied.

Ensure that jumper settings are compatible with the motor being controlled.

The MMVFD series is equipped with four jumper terminals, which control different aspects of drive operation. Refer to

Figure 15 (page 27) for terminal locations.

Drive phase output (JMP501 and JMP502)

JMP501 and JMP502 must be set to match the phase of the motor being controlled. The factory (default) setting is three-phase operation (terminals 1 and 2 jumpered). Refer to Table 2 for optional jumper settings.

Table 2. Jumper Settings

Motor JMP501 JMP502

Operation

Single-phase

Two-phase

Three-phase

Settings

2-3

2-3

1-2

Settings

2-3

1-2

1-2

250-0289 rev1.qxd 3/9/01 10:45 AM Page 24

24

Operation

Acceleration mode select (JMP503)

The MMVFD-D230AC series is equipped with a dual V/Hz feature, which allows the setting of a linear or variable V/Hz characteristic. The linear setting should be used for all constant torque applications. The use of the variable characteristic in the appropriate applications can save energy at speeds below the base motor speed. Figure 13 (page 26) shows a simple graph illustrating the difference between linear- and variable-V/Hz modes.

Linear acceleration mode produces a constant V/Hz and torque

(current) output from the drive.

In contrast, variable-torque mode produces a variable V/Hz and torque (current) output from the drive. As a result, fans and centrifugal pumps, which normally dissipate energy at low speeds, can be much more efficient.

For linear-torque mode, jumper terminals 1 and 2 of JMP503 (this is the factory setting). For variable-torque mode, jumper terminals 2 and 3. Refer to Figure 15 (page 27) for terminal locations, and Figure 17 (page 28) for jumper settings.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 25

Operation

Braking mode select (JMP504)

The MMVFD series is equipped with DC injection braking, for use with high-inertia applications (see Figure 14, page 26).

25

As a rule, DC motors do not convert AC ripple in the DC signal to mechanical energy; instead, it is dissipated as waste heat. AC motors perform in the opposite fashion: any DC component of an

AC signal is converted to mechanical energy and acts as drag on an AC motor.

When injection braking is selected and the drive is disabled, the normal AC phase output to the motor from the drive is set to its minimum frequency. The drive simultaneously introduces a DC voltage (not to exceed the threshold set by the CURRENT LIMIT trimpot) into the motor stator for two (2) seconds. The motor will brake for two seconds, then coast to a stop. This stops the motor much more quickly and efficiently than simply coasting to a stop, while avoiding high currents which may damage the motor and drive.

For normal operation, jumper terminals 1 and 2 of terminal

JMP504 (this is the factory setting). To enable DC injection braking, jumper terminals 2 and 3. Refer to Figure 15 (page 27) for terminal locations, and Figure 17 (page 28) for jumper settings.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 26

26

Operation

Figure 13. MMVFDxx-D230AC Acceleration Personality

Figure 14. MMVFDxx-D230AC Braking Personality

250-0289 rev1.qxd 3/9/01 10:45 AM Page 27

Operation

27

JMP501

JMP503

JMP504

JMP502

MMVFDxx-115AC and MMVFDxx-230AC

JMP504 JMP503 JMP501 JMP502

MMVFDxx-D230AC

Figure 15. Jumper Terminal Locations

250-0289 rev1.qxd 3/9/01 10:45 AM Page 28

28

Operation

MOTOR PHASE JUMPER SETTINGS (JMP501 AND JMP502)

SEE NOTE 1

NOTES ON JUMPER SETTINGS:

SEE NOTE 2 SEE NOTE 3

1) 3-PHASE MOTOR

2) SINGLE-PHASE MOTOR WITH PREWIRED RUN CAPACITOR

3) SINGLE-PHASE MOTOR WITHOUT PREWIRED RUN CAPACITOR (2-

PHASE OPERATION)

ACCEL/TORQUE SETTINGS

(JMP503)

BRAKING SETTINGS

(JMP504)

NORMAL

OPERATION

NORMAL

OPERATION

VARIABLE

TORQUE

ENABLED

DC INJECTION

BRAKING

ENABLED

Figure 16. Jumper Settings

250-0289 rev1.qxd 3/9/01 10:45 AM Page 29

Operation

Voltage doubler output

Warning

Do not connect 230 VAC line input to the 115 VAC terminals.

This will result in severe damage to the motor and drive, possible explosion and severe injury.

29

MMVFDxx-D230AC-series drives are equipped with a unique voltage-doubling feature, for use when 230 VAC input voltage is not available. This feature converts a 115 VAC input to a 230

VAC output, for use with 230V motors. The drive current output remains the same.

Refer to Figure 7 (page 14) for connection information. Use extreme caution when connecting this feature. Incorrect use of this feature may result in fire and serious injury.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 30

30

Operation

Startup

Warning

Do not change jumper settings with power applied.

Ensure that jumper settings are compatible with the motor being controlled.

1. Verify that no conductive material is present on the PCB.

2. Verify that the correct voltage is connected to the inputs before applying power. DO NOT CONNECT 230 VAC

LINE VOLTAGE TO A 115 VAC DRIVE. Applying power in this manner will damage the motor and drive.

3. Verify that jumpers are set to the correct phasing for the motor under load.

4. Set the speed adjust potentiometer to zero (full CCW).

5. Set the DIR switch (if installed) to the desired direction. If no switch is installed, install or remove a jumper across the DIR and COM terminals, as required.

6. Set the ENABLE/DISABLE switch (if installed) to ENABLE, or short the ENABLE (EN) and COM terminals on TB501.

7. Apply 115 or 230 VAC, 50/60 Hz, single-phase power to the drive. The green POWER LED will come on after an initial delay of 1- 2 seconds, in which all logic circuits are checked for proper function. If the POWER LED does not light, check the external line fuses to ensure that they are properly installed and not blown.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 31

Operation

31

8. If you attempt to start and the red TQ LIMIT LED comes on, the control has entered torque limit mode. To avoid this occurrence, you may: a. increase the torque limit setting*, or b. lengthen the acceleration time enough to accommodate the needed starting torque by adjusting the ACCEL trimpot.

To reverse motor direction:

To reverse the direction of motor shaft rotation while the motor is running, set the DIR switch to the opposite position. If no DIR switch is installed, open or short the DIR and COM terminals on

TB501, as required.

When a new direction is selected, there is no need to close the

BRAKE input or open the ENABLE input. The control will automatically decelerate the motor down to zero speed and then reverse direction, accelerating and decelerating at a rate controlled by the ACCEL/DECEL trimpot setting.

*Do not set the torque limit setting above 150% of the motor’s nameplate current rating.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 32

32

Operation

Starting and stopping methods

To coast the motor to a stop without disconnecting power:

Open the ENABLE/DISABLE switch, or remove the jumper between the ENABLE (EN) and COM terminals of TB501. Refer to Application Notes (page 41) for instructions on switch installation.

Thermal protection of the motor

The enable input can also act as a motor thermal protection circuit for motors having a built-in thermal protector. These thermal protectors are operated only by motor heat and open the enable circuit when the motor reaches a temperature which could cause damage to the motor winding.

Normally, these thermal protectors automatically close the circuit when the motor has cooled to a safe temperature. In operation, when the drive is disabled, or when the motor overheats, the thermal protector opens the circuit (Figure 17).

250-0289 rev1.qxd 3/9/01 10:45 AM Page 33

Operation

33

Figure 17. Thermal Overload Switch with Optional Enable/Disable Switch

Line starting and line stopping

Minarik strongly recommends the installation of a master

power switch in the voltage input line (see Power and Fuse

Connections, pg. 11). The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts.

Line starting and line stopping (applying and removing AC voltage input) is recommended for infrequent starting and stopping of the drive only. It is also the recommended method for emergency stopping of the drive. When AC voltage input is applied to the drive, the motor accelerates to the speed set by the speed adjust potentiometer. When AC voltage input is removed, the motor coasts to a stop. To “jog” a motor, install a normallyopen pushbutton switch on the ENABLE input.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 34

34

Calibration

Warning

Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the voltage input from the drive before adjusting the trimpots. If the trimpots must be adjusted with power applied, use insulated tools and the appropriate personal protection equipment. BE ALERT. High voltages can cause serious or fatal injury.

The MMVFD series has seven user-adjustable trimpots. Each drive is factory calibrated to its maximum horsepower rating.

Readjust the calibration trimpot settings to accommodate lower horsepower motors. See Figure 18 for MMVFDxx-D230AC trimpot location. See Figure 19 (page 36) for MMVFDxx-

115/230AC trimpot location.

All adjustments increase with CW rotation and decrease with

CCW rotation. Use a non-metallic screwdriver for calibration.

Each trimpot is identified on the printed circuit board.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 35

Calibration

35

TORQUE

LIMIT

DECELERATION

ACCELERATION

MINIMUM

SPEED

MAXIMUM

SPEED

BOOST V/HZ

Figure 18. MMVFDxx-D230AC Calibration Trimpot Layout

250-0289 rev1.qxd 3/9/01 10:45 AM Page 36

36

Calibration

V/HZ

BOOST

TORQUE

LIMIT

DECELERATION

ACCELERATION

MINIMUM

SPEED

MAXIMUM

SPEED

Figure 19. MMVFDxx-115AC and MMVFDxx-230AC

Calibration Trimpot Layout

250-0289 rev1.qxd 3/9/01 10:45 AM Page 37

Calibration

Calibration Procedure Setup for 60 Hz

Motors:

37

1. Set the ENABLE switch to the DISABLE (open) position. If no switch is installed, remove the jumper between the

ENABLE (EN) and COM terminals of TB501.

2. Set the DIR switch to the FWD (open) position. If no switch is installed, remove the jumper between the DIR and COM terminals of TB501.

3. Set all trimpots except TQ LIM and V/HZ fully counterclockwise (CCW).

4. Set the TQ LIM trimpot to maximum (full CW).

5. Set the V/Hz trimpot to center of travel (12 o’clock position).

6. Set JMP501 & JMP502 to 1-2 position (3-phase output).

7. Set the speed adjust pot to zero (full CCW).

8. Calibrate the trimpots as follows:

MINIMUM SPEED (MIN SPD)

1. Apply power to the drive.

2. Set the ENABLE switch to the ENABLE (closed) position.

3. Slowly rotate the MIN SPD trimpot CW until the motor begins to turn, then slowly rotate the pot CCW until the motor just stops.

This step calibrates the MIN SPD pot to zero speed without hysteresis.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 38

38

Calibration

MAXIMUM SPEED (MAX SPD)

Rotate the speed adjust pot full CW. Using a hand-held tachometer or analog frequency meter as a reference, adjust the

MAX SPD trimpot until the desired speed or frequency is reached.

TORQUE LIMIT (TQ LIM)

Warning

Although the TQ LIM trimpot can be set up to 120% of the drive nameplate rating, continuous operation beyond the drive nameplate rating may cause damage to the motor and/or drive.

1. With no power applied to the drive, connect a DC ammeter in series with the motor armature.

2. Set the TQ LIM trimpot to full CCW.

3. Carefully lock the motor armature. Ensure that the motor is firmly mounted.

4. Apply line power. The motor should be stopped.

5. Set the speed potentiometer or reference signal to maximum speed. The motor should remain stopped.

6. Slowly rotate the TQ LIM trimpot clockwise (CW) until the ammeter reads 120% of maximum motor armature current.

7. Set the speed adjust potentiometer or reference signal to zero speed.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 39

Calibration

8. Remove power from the drive.

9. Remove the lock from the motor shaft.

10. Remove the ammeter in series with the motor armature.

BOOST

39

The boost trimpot is used to increase motor torque at low speeds.

The minimum setting is sufficient for most applications and does not need to be adjusted. If the motor runs rough or noisily at low speeds, the boost trimpot may need adjustment. Contact your

Minarik representative for assistance.

ACCELERATION (ACCEL)

1. Set the speed adjust pot to zero (full CCW) and wait for the motor to come to a stop (or minimum speed).

2. Set the speed adjust pot or reference signal to maximum speed (full CW) and note the time the motor takes to accelerate to maximum speed.

3. If the acceleration time differs from the desired time, adjust the ACCEL trimpot until the desired time is reached.

Rotating the ACCEL pot CW increases the acceleration time.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 40

40

Calibration

DECELERATION (DECEL)

1. Set the speed adjust pot to maximum (full CW) and wait for the motor to come to maximum speed.

2. Set the speed adjust pot to minimum speed (full CCW) and note the time the motor takes to decelerate to minimum speed.

3. If the deceleration time differs from the desired time, adjust the DECEL trimpot until the desired time is reached.

Rotating the DECEL pot CW increases the deceleration time.

Calibration Procedure Conclusion

1. Set the speed adjust pot to zero (full CCW).

2. Disable the drive by opening the ENABLE/DISABLE switch or removing the jumper from the ENABLE (EN) and COM terminals.

3. Remove power to the motor and drive. Calibration is now complete.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 41

41

Application Notes

Decelerate to minimum speed

The circuit shown in Figure 20 may be used to decelerate a motor to a minimum speed. Closing the switch between S2 and S1 decelerates the motor from set speed to a minimum speed determined by the MIN SPD trimpot setting. If the MIN SPD trimpot is set full CCW, the motor decelerates to zero speed when the switch is closed. Calibrate the ACCEL and DECEL trimpots to control the acceleration and deceleration ramp. Set the switch to the RUN position to accelerate the motor to set speed.

Figure 20. Run/Decelerate to Minimum Speed Switch

250-0289 rev1.qxd 3/9/01 10:45 AM Page 42

42

Application Notes

Independent adjustable speeds with

DIR switch

Replace the speed adjust potentiometer with two single-pole multi-position switches, and two or more potentiometers in parallel, with a total parallel resistance of 10K ohms. Figure 21 shows the connection of two independent speed adjust potentiometers that can be mounted at two separate operating stations.

Figure 21. Independent Adjustable Speeds

250-0289 rev1.qxd 3/9/01 10:45 AM Page 43

Application Notes

43

RUN/JOG switch

Using a RUN/JOG switch is recommended in applications where quick stopping is not needed and frequent jogging is required.

Use a single-pole, two-position switch for the RUN/JOG switch, and a single-pole, normally open, momentary operated pushbutton for the JOG pushbutton.

Connect the RUN/JOG switch and JOG pushbutton to terminal board TB501 as shown in Figure 22. The motor coasts to a stop when the RUN/JOG switch is set to JOG. Press the JOG pushbutton to jog the motor. Return the RUN/JOG switch to RUN for normal operation.

Figure 22. RUN/JOG Switch

250-0289 rev1.qxd 3/9/01 10:45 AM Page 44

44

Application Notes

Single speed potentiometer control of multiple motors

Warning

The combined current draw of all motors must not exceed the current rating of the drive.

The MMVFD series of controls is capable of operating up to eight 3-phase motors simultaneously. All motors must be of the same type and must control similar loads. Connect each motor as shown in Figure 23 below.

MMVFD

SERIES

DRIVE

Figure 23. Single Speed Potentiometer Control of Multiple Motors

250-0289 rev1.qxd 3/9/01 10:45 AM Page 45

45

Troubleshooting

Warning

Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the voltage input from the drive while troubleshooting. BE ALERT. High voltages can cause serious or fatal injury.

Before troubleshooting

Perform the following steps before starting any procedure in this section:

• Disconnect AC or DC voltage input from the drive. Wait 60 seconds for power to discharge. The green POWER LED will blink while power is discharging.

• Check the drive closely for damaged components.

• Check that no wire, chips, or other foreign material has become lodged on the printed circuit board.

• Verify that every connection is correct and in good condition.

• Verify that there are no short circuits or grounded connections.

• Check that the drive’s rated phase current and RMS voltage are consistent with the motor ratings.

For additional assistance, contact your local Minarik® distributor, or the factory direct by telephone at:

1-800-MINARIK (646-2745) or Fax: 1-800-394-6334

250-0289 rev1.qxd 3/9/01 10:45 AM Page 46

46

Troubleshooting

Diagnostic LEDs

Minarik’s MMVFD series is equipped with diagnostic LEDS to assist the user in troubleshooting and monitoring equipment status while in use. Refer to Figure 24 for diagnostic LED locations.

Power

NOTE:

The MMVFDxx-D230AC series has two POWER

LEDS (one LED on each board).

The green POWER LED lights when AC line voltage is applied and the control’s low-voltage power supply is operational.

TQ LIMIT (MMVFDxx-D230AC series only)

The red TORQUE LIMIT LED lights when the drive output current exceeds the threshold set by the TQ LIMIT trimpot. If this LED lights, shut down the motor and drive by the disabling method or by removing power. Check the motor to make sure it is not jammed or overloaded. The TQ LIMIT trimpot may need to be recalibrated. See the Calibration section (page 34) for information on calibrating the TQ LIMIT trimpot.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 47

Troubleshooting

47

POWER

LED

TORQUE

LIMIT

LED

MMVFDxx-115AC and MMVFDxx-230AC Series

POWER

LED

MMVFDxx-D230AC Series

Figure 24. Diagnostic LED location

250-0289 rev1.qxd 3/9/01 10:45 AM Page 48

48

Troubleshooting

Problem Possible

Cause

Suggested

Solution

External line fuse blows

External line fuse does not blow, but the motor does not run

1. Line fuses are the wrong size.

2. Motor or motor cable is shorted to ground.

3. Nuisance tripping caused by a combination of ambient conditions and highcurrent spikes

(i.e. reversing).

1. Speed adjust potentiometer or voltage input signal is set to zero speed.

2. Speed adjust potentiometer or voltage input signal is not properly connected to drive input; connections are open.

1. Check that line fuses are properly sized for the motor being used.

2. Check motor cable and motor for shorts.

3. Add a blower to cool the drive components; increase

TQ LIM settings

(page 38).

1. Increase the speed adjust potentiometer setting or voltage input signal.

2. Check connections to input. Verify that connections are not open.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 49

Problem Possible

Cause

Troubleshooting

Suggested

Solution

49

External line fuse does not blow, but the motor does not run (cont.)

Motor runs too slow or too fast at set speed

Motor will not reach the desired speed

3. Drive is “tripped” off or has gone into thermal overload.

4. Drive has been disabled.

5. Drive is in current limit.

6. Drive is not receiving

AC voltage input.

7. Motor is not connected.

1. MIN and MAX SPD are not calibrated correctly.

1. MAX SPD setting is too low.

3. Disable, then reenable the drive.

4. Ensure that

ENABLE (EN) and

COM terminals are properly connected.

5. Verify that motor is not jammed.

Increase TQLIM setting if it is set too low (page 38).

6. Apply AC line voltage to L1 and L2.

7. Connect motor to drive outputs U, V and W.

1. Calibrate MIN and

MAX SPD trimpots

(pp 37-38).

1. Increase MAX

SPD setting (page

38).

250-0289 rev1.qxd 3/9/01 10:45 AM Page 50

50

Troubleshooting

Problem Possible

Cause

Suggested

Solution

Motor will not reach the desired speed (cont.)

Motor pulsates or surges under load

Motor does not reverse

2. Nominal input voltage may be too low for motor

3. Motor is overloaded.

1. Motor “bouncing” in and out of torque limit.

1. Bad DIR switch connection.

2. Reversing circuit not working properly.

2. Compare motor voltage to input voltage; replace motor if necessary

3. Check motor load.

Resize the motor or drive if necessary.

1. Make sure motor is not undersized for load; adjust TQ LIM setting CW (page

38).

1. Check DIR switch connection.

2. Check reversing circuit by shorting

DIR terminal to

COM terminal with jumper wire.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 51

Problem Possible

Cause

Troubleshooting

Suggested

Solution

51

TQ is unsatisfactory at high speeds.

1. TQ LIMIT set too low.

2. TQ BOOST set too low.

3. Load may exceed rating of motor/drive.

4. Nominal input voltage may be too low for motor.

1. Check TQ LIM setting (page 38).

2. Check TQ

BOOST setting (page

39).

3. “Fix” load (i.e., straighten mounting, coupling, etc.); or replace motor and drive with motor and drive rated for higher horsepower.

4. Compare motor voltage to input voltage. Replace motor if necessary.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 52

52

Troubleshooting

Replacement Parts

Replacement parts are available from Minarik Corporation and its distributors for this drive series.

Table 3. Replacement Parts

Description Minarik

®

P/N Model No.

MMVFD03-115AC

Symbol

C502

C503

C504

Q501-Q506

TH501

TB501

120 uF, 25 VDC Capacitor

1500 uF, 250 VAC Capacitor

47 uF, 35 VDC Capacitor

IGBT

20-amp Thermistor

6-pin Wago Terminal Block

10k ohm Potentiometer Kit

011-0122

011-0089

011-0066

070-0085

033-0007

160-0163

202-0099

MMVFD04-115AC

C503

MMVFD03-230AC

C503

MMVFD04-230AC

C503

MMVFD03-D230AC

C501-502

C503-504

C505

Same as above, except:

1500 uF, 250 VAC Capacitor 011-0089

Same as 115 VAC models, except:

470 uF, 400 VAC Capacitor 011-0120

Same as 115 VAC models, except:

1000 uF, 400 VAC Capacitor 011-0099

Same as 115 VAC models, except:

820 uF, 250 VDC Capacitor 011-0135

.01 uF, 1000 VDC Capacitor

120 uF, 25 VDC Capacitor

10k ohm Potentiometer Kit

010-0015

011-0122

202-0101

250-0289 rev1.qxd 3/9/01 10:45 AM Page 53

MMVFD04-D230AC

C501 - 503

Potentiometer kit 202-0099

Troubleshooting

Same as 115 VAC models, except:

1500 uF, 250 VAC Capacitor 011-0089

53

Potentiometer kit 202-0101

10K ohm, 5W Potentiometer

3/8-32 X 1/2 Nut

3/8IN Int. Tooth Lockwasher

Pot Insulating Washer

Non-insulated Female Connector

Same as above except

3 ea Insulated Female Connector

250-0289 rev1.qxd 3/9/01 10:45 AM Page 54

54

Index

Application Notes

Decelerate to minimum speed: 41

Independent adjustable speeds with DIR switch: 42

RUN/JOG switch: 43

Single speed potentiometer control of multiple motors: 44

Calibration: 34

Calibration Procedure Setup for 60 Hz Motors: 37

ACCEL trimpot: 39, 40

BOOST trimpot: 39

Calibration Procedure Conclusion: 40

DECEL trimpot: 40

MAX SPD trimpot: 38

MIN SPD trimpot: 37

TQ LIM trimpot: 38

Contents: vi

Dimensions: 2

General Information: ii

Important Information: v

MMVFD Series Features: iv

Illustrations: viii

Figure 1. MMVFDxx-115AC and MMVFDxx-230AC Dimensions: 2

Figure 2. MMVFDxx-D230AC Dimensions: 3

Figure 3. Heat SinkDimensions: 4

Figure 4. Speed Adjust Potentiometer: 9

Figure 5. Cage-Clamp Terminal: 10

Figure 6. AC Line and Fuse Connections for MMVFDxx-115AC and MMVFDxx-

230AC Series Drives: 12

Figure 7. AC Line and Fuse Connections for MMVFDxx-D230AC Series Drives

(115 VAC Input): 14

250-0289 rev1.qxd 3/9/01 10:45 AM Page 55

Index

55

Figure 8. AC Line and Fuse Connections for MMVFDxx-D230AC Series Drives

(230 VAC Input): 14

Figure 9. Motor Connections for Single-Phase Operation (Motor With Pre-

Wired Capacitor): 16

Figure 10. Motor Connections for Two-Phase Operation (NoPre-Wired

Capacitor): 18

Figure 11. Motor Connections for Three-Phase Motors: 19

Figure 12. Signal and Optional Switch Connections: 21

Figure 13. MMVFDxx-D230AC Acceleration Personality: 26

Figure 14. MMVFDxx-D230AC Braking Personality: 26

Figure 15. Jumper Terminal Locations: 27

Figure 16. Jumper Settings: 28

Figure 17. Thermal Overload Switch with Optional Enable/Disable Switch: 33

Figure 18. MMVFDxx-D230AC Calibration Trimpot Layout: 35

Figure 19. MMVFDxx-115AC and MMVFDxx-230AC Calibration Trimpot

Layout: 36

Figure 20. Run/Decelerate to Minimum Speed Switch: 41

Figure 21. Independent Adjustable Speeds: 42

Figure 22. Run/Decelerate to Stop Switch: 41

Figure 23. Independent Adjustable Speeds: 42

Figure 24. RUN/JOG Switch: 43

Figure 25. Single Speed Potentiometer Control of Multiple Drives: 44

Figure 27. Diagnostic LED location: 47

Installation: 5

Cage-clamp terminals: 10

Connections: 11

Motor connections (all MMVFD-series controls): 15

Single-phase operation: 15

Three-phase operation: 17

Two-phase operation: 17

Power and fuse connections: 11

MMVFDxx-115AC and MMVFDxx-230AC series: 11

MMVFDxx-D230AC series: 13

250-0289 rev1.qxd 3/9/01 10:45 AM Page 56

56

Index

Installation ( cont.)

Signal and Optional Switch Connections: 20

DIRECTION (DIR) switch: 20

ENABLE/DISABLE switch: 20

Speed adjust potentiometer: 20

Fusing: 8

Heat sinking: 8

Mounting: 5

Speed adjust potentiometer: 9

Wiring: 6

Shielding guidelines: 7

Operation: 22

Jumper Settings: 23

Acceleration mode select (JMP503): 24

Braking mode select (JMP504): 25

Drive phase output (JMP501 and JMP502): 23

Starting and stopping methods: 32

Line starting and line stopping: 33

Thermal protection of the motor: 32

To coast the motor to a stop without disconnecting power: 32

Startup: 30

To reverse motor direction: 31

Voltage doubler output: 29

Safety Warnings: i

Specifications: 1

Tables: ix

Table 1. Line Fusing Chart: 8

Table 2. Jumper Settings: 23

Table 3. Replacement Parts: 52

250-0289 rev1.qxd 3/9/01 10:45 AM Page 57

Index

57

Troubleshooting: 45

Before troubleshooting: 45

Diagnostic LEDs: 46

Power: 46

TQ LIMIT (MMVFDxx-D230AC series only): 46

Replacement Parts: 52

Troubleshooting Tree: 48

Unconditional Warranty: 56

250-0289 rev1.qxd 3/9/01 10:45 AM Page 58

Notes

250-0289 rev1.qxd 3/9/01 10:45 AM Page 59

Unconditional Warranty

A. Warranty

Minarik Corporation (referred to as “the Corporation”) warrants that its products will be free from defects in workmanship and material for twelve (12) months from date of manufacture thereof. Within this warranty period, the Corporation will repair or replace such products that are returned to Minarik Corporation, 901 East

Thompson Avenue, Glendale, CA 91201-2011 USA.

This warranty shall not apply to any product that has been repaired by unauthorized persons. The Corporation is not responsible for removal, installation, or any other incidental expenses incurred in shipping the product to and from the repair point.

B. Disclaimer

The provisions of Paragraph A are the Corporation’s sole obligation and exclude all other warranties of merchantability for use, express or implied. The Corporation further disclaims any responsibility whatsoever to the customer or to any other person for injury to the person or damage or loss of property of value caused by any product that has been subject to misuse, negligence, or accident, or misapplied or modified by unauthorized persons or improperly installed.

C. Limitations of Liability

In the event of any claim for breach of any of the Corporation’s obligations, whether express or implied, and particularly of any other claim or breech of warranty contained in Paragraph A, or of any other warranties, express or implied, or claim of liability that might, despite Paragraph B, be decided against the

Corporation by lawful authority, the Corporation shall under no circumstances be liable for any consequential damages, losses, or expense arising in connection with the use of, or inability to use, the Corporation’s product for any purpose whatsoever.

An adjustment made under warranty does not void the warranty, nor does it imply an extension of the original 12-month warranty period. Products serviced and/or parts replaced on a no-charge basis during the warranty period carry the unexpired portion of the original warranty only.

If for any reason any of the foregoing provisions shall be ineffective, the

Corporation’s liability for damages arising out of its manufacture or sale of equipment, or use thereof, whether such liability is based on warranty, contract, negligence, strict liability in tort, or otherwise, shall not in any event exceed the full purchase price of such equipment.

Any action against the Corporation based upon any liability or obligation arising hereunder or under any law applicable to the sale of equipment or the use thereof, must be commenced within one year after the cause of such action arises.

250-0289 rev1.qxd 3/9/01 10:45 AM Page 60

901 E Thompson Avenue

Glendale, CA 91201-2011

Tel: 1-(800)-MINARIK

Fax:

1-(800)-394-6334

www.minarikcorp.com

Document number 250–0289, Revision 1

Printed in the U.S.A – 01/01

North America $12.00, Outside North America $15.00

Was this manual useful for you? yes no
Thank you for your participation!