Timers and Counters

Timers and Counters
®
INDUSTRIAL SOLID STATE MODEL 1010
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
Fast cycle rate timer available in four timing functions.
Features:
•External plug-in DPDT relay / accessory solid state output.
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120 or 230 VAC input.
•10 amp relay output.
•Remote adjust capability.
•Optional timing indication LED
TIMING
ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset either by
removing power or control.
OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When control turns off, the delay starts and output
turns off after time elapses.
PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on. Output
remains on while delay time elapses.
• Turning control on and off during delay time has no
effect on the output or timing.
INTERVAL
• Control is independent of unit power.
• When control turns on, output turns on and delay
time elapses before output returns to normal.
• If control changes during the delay time period, the
output turns off and the delay time will reset.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1010
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC/230VAC
50/60Hz
±15% of nominal
10VA maximum
Isolation transformer
TYPE:
RATING:
Electromechanical relay ( solid state available as an accessory)
10A @ 240VAC maximum
OUTPUT
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
INDICATION:
ON Delay, OFF Delay, Pulse Interval, Interval
±1% of setting
Optional LED - on when timing
(OFF Delay - LED on when output energized)
TIMING RAMP:
0.06 sec. minimum time - 100kΩ/sec.,
0.5 sec. minimum time - 10kΩ/sec.
TIME RANGE:
0.06 to 500 seconds in 12 ranges
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
E-F
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC min./40VDC max.
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum
Base mount
Terminal blocks on face of timer
Metal
DIMENSIONS inch (mm)
WIRING
OUTPUT B
A-B Voltage Input
(constant)
C-D Remote Adjust
(jumper not used)
E-F Control
(starts timing function)
G-H Not used
1-2 N.O. timed
3-4 N.C. timed
5-6 N.C. timed
7-8 N.O. timed
Wiring Terminal Location
7
6
8
5
1
4
2
3
A
H
B
G
C
F
D
E
Caution: Never apply voltage
to terminals C-D-E-F
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1010
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1010
INPUT VOLTAGE
1
2
TIME RANGE (secs)
A
B
C
D
E
F
G
H
J
K
L
M
W
TIMING FUNCTION
1
2
4
5
OUTPUT
B
OPTION (If desired)
OP6
1010 - 1 - F - 4 - B
---
120 VAC
230 VAC
0.06 - 0.10
0.06 - 0.25
0.06 - 0.50
0.06 - 1.0
0.06 - 2.5
0.06 - 5.0
0.06 - 10.0
0.06 - 25.0
0.5 - 50.0
0.5 - 100
0.5 - 250
0.5 - 500
Factory fixed
(within 5% of customer specified time)
ON Delay
OFF Delay
Pulse Interval
Interval
Relay DPDT
(see accessories for solid state plug in outputs)
Timing indication light
(on when timing / OFF Delay - on when output energized)
APPLICABLE ACCESSORIES
See accesory section for details
Output modules
Potentiometers
Reference dial
Locking attachment
RP-101, RP-104 thru RP-106
RP-201 thru RP-210
RP-216
RP-217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1012
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Available in three timing functions
Features:
•12 pin plug-in base.
•Control contacts independant of input power.
•Time ranges from 0.06 to 500 seconds.
•120 or 24 VAC input.
•10 amp relay output.
•Remote adjust capability.
•Optional timing indication LED
TIMING
ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset either
by removing power or control.
OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When the control turns off, the delay starts and
output turns off after time elapses.
PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on. Output
remains on while delay time elapses.
• Turning control on and off during delay time has no
effect on the output or timing.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1012
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC, 24VAC/DC
50/60Hz
±15% of nominal
10VA maximum
Isolation transformer (120VAC only)
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay
10,000,000 operations
300,000 operations
10A @ 240VAC maximum
OUTPUT
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
INDICATION:
TIMING RAMP:
ON Delay, OFF Delay, Pulse Interval
±1% of setting
Optional LED - on when timing
0.06 sec. minimum time - 100kΩ/sec.,
0.5 sec. minimum time - 10kΩ/sec.
TIME RANGE:
0.06 to 500 seconds in 9 ranges
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
5-6
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC min./40VDC max.
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
DIMENSIONS inch (mm)
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum
Plug-In
12-pin socket
Metal
WIRING
OUTPUT B
1-2
Voltage Input
(constant)
3-4
Remote Adjust
(jumper not used)
5-6
Control
(starts timing function)
7-8
N.O. timed
8-9
N.O. timed
10-11 N.C. timed
11-12 N.C. timed
Wiring Terminal Location
12-Pin Socket
Caution: Never apply voltage
to terminals 3-4-5-6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1012
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1012
INPUT VOLTAGE
1
2
TIME RANGE (secs)
D
E
F
G
H
J
K
L
M
W
TIMING FUNCTION
1
2
4
OUTPUT
B
OPTION (If desired)
OP6
1012 - 1 - E - 1 - B
---
120 VAC
24 VAC/DC
0.06 - 1.0
0.06 - 2.5
0.06 - 5.0
0.06 - 10.0
0.06 - 25.0
0.5 - 50.0
0.5 - 100
0.5 - 250
0.5 - 500
Factory fixed
(within 5% of customer specified time)
ON Delay
OFF Delay
Pulse Interval
Relay DPDT
Timing indication light
(on when timing / OFF Delay - on when output energized)
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
12 pin socket (one included)
RP-201 thru RP-210
RP-216
RP-217
RP-301
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1013
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
Fast cycle rate timer available in four timing functions.
Features:
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120 VAC input.
•10 amp relay output.
•Remote adjust capability.
•LED indicating timing
TIMING
ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset either
by removing power or control.
OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When control turns off, the delay starts and output
turns off after time elapses.
PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on.
Output remains on while delay time elapses.
• Turning control on and off during delay time has no
effect on the output or timing.
INTERVAL
• Control is independent of unit power.
• When control turns on, output turns on and delay
time elapses before output returns to normal.
• If control changes during the delay time period,
the output turns off and the delay time will reset.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1013
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC
50/60Hz
±15% of nominal
10VA maximum
Isolation transformer
TYPE:
RATING:
Electromechanical relay
10A @ 240VAC maximum
OUTPUT
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
RESET TIME:
INDICATION:
TIMING RAMP:
ON Delay, OFF Delay, Pulse Interval, Interval
±1% of setting
50 msec minimum
LED - On when timing.
0.06 sec. minimum time - 100kΩ/sec.,
0.5 sec. minimum time - 10kΩ/sec.
TIME RANGE:
0.06 to 500 seconds in 12 ranges
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
E-F
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC min./40VDC max.
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum
Base mount
Terminal blocks on face of timer
Metal
DIMENSIONS inch (mm)
WIRING
OUTPUT B, B1, B2
Wiring Terminal Location
A-B Voltage Input
(constant)
C-D Remote Adjust
(jumper not used)
E-F Control
(starts timing function)
1-2 N.O. timed
(except B2, N.C.)
3-4 N.O. timed
(except B1, N.O.)
Caution: Never apply voltage
to terminals C-D-E-F
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1013
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1013
INPUT VOLTAGE
1
TIME RANGE (secs)
A
B
C
D
E
F
G
H
J
K
L
M
W
TIMING FUNCTION
1
2
4
5
OUTPUT
B
1013 - 1 - A - 2 - B
120 VAC
0.06 - 0.10
0.06 - 0.25
0.06 - 0.50
0.06 - 1.0
0.06 - 2.5
0.06 - 5.0
0.06 - 10.0
0.06 - 25.0
0.5 - 50.0
0.5 - 100
0.5 - 250
0.5 - 500
Factory fixed
(within 5% of customer specified time)
ON Delay
OFF Delay
Pulse Interval
Interval
Relay DPDT
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
RP-201 thru RP-210
RP-216
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1014
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
Instant contacts energize with application of
control signal while timed contacts follow
timing function.
Features:
•Control compatible with AC proximity sensors.
•Control independant of input power.
•Time ranges from 0.06 to 500 seconds.
•120 VAC input.
•10 amp relay output.
•Remote adjust capability.
•Timing indicating LED.
TIMING
ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
timed output turns on.
•The timed output remains on until the unit is reset
either by removing power or control.
• Instant output directly follows control input.
OFF DELAY
• Control is independent of unit power.
• When control turns on, timed output turns on.
• When control turns off, the delay starts and timed
output turns off after delay elapses.
• Instant output directly follows control input.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1014
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC
50/60Hz
±15% of nominal
10VA maximum
Isolation transformer
TYPE:
RATING:
Two electromechanical relays
10A @ 240VAC maximum
OUTPUT
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
RESET TIME:
INDICATION:
TIMING RAMP:
ON Delay, OFF Delay
±1% of setting
50 msec minimum
LED - On when timing.
0.06 sec. minimum time - 100kΩ/sec.,
0.5 sec. minimum time - 10kΩ/sec.
TIME RANGE:
0.06 to 500 seconds in 12 ranges
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure or AC proximity sensor.
CONTROL TERMINALS:
A-C
VOLTAGE PRESENT AT CONTROL TERMINALS: Same as input voltage.
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum
Base mount
Terminal blocks on face of timer
Metal
WIRING
OUTPUT A
A-B
A-C
1-2
3-4
4-5
6-7
7-8
9-10
Voltage Input (constant)
Control (starts timing function)
Remote Adjust (jumper not used)
N.O. instant
N.C. instant
N.O. timed
N.C. timed
N.O. timed
OUTPUT B
A-B
A-C
1-2
2-3
4-5
6-7
7-8
9-10
Voltage Input (constant)
Control (starts timing function)
N.O. instant
N.C. instant
N.O. instant
N.O. timed
N.C. timed
N.O. timed
DIMENSIONS inch (mm)
Wiring Terminal Location
1
2
3
A
B
C
6
7
8
4
5
9
10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1014
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1014
INPUT VOLTAGE
1
TIME RANGE (secs)
A
B
C
D
E
F
G
H
J
K
L
M
W
TIMING FUNCTION
1
2
OUTPUT
A
B
1014 - 1 - G - 2 - B
120 VAC
0.06 - 0.10
0.06 - 0.25
0.06 - 0.50
0.06 - 1.0
0.06 - 2.5
0.06 - 5.0
0.06 - 10.0
0.06 - 25.0
0.5 - 50.0
0.5 - 100
0.5 - 250
0.5 - 500
Factory fixed
(within 5% of customer specified time)
ON Delay
OFF Delay
Instant Relay 1 SPDT
Timed Relay 1 SPDT, 1 N.O.
Instant Relay 1 SPDT, 1 N.O.
Timed Relay 1 SPDT, 1 N.O.
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
RP-201 thru RP-210
RP-216
RP-217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE 1017SP7
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ON Delay timer for electric utility applications.
Features:
•Input power initiates the timing sequence.
•High voltage DC switching capablity.
•Equipped with transient voltage protection.
•Metal housing to maximize noise immunity.
•Time ranges from 1.5 cycles (60Hz) to 300 seconds.
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset by
removing power.
SPECIFICATIONS
INPUT
VOLTAGE:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
24VAC/DC, 48VAC/DC, 120VAC/125VDC, 240VAC/250VDC
±15% of nominal, ±10% for 24V
16W maximum
TVS Diode
TYPE:
RATING:
Electromechanical relay
3A @ 150VDC maximum, 10A @ 240VAC 80% PF maximum
AVAILABLE TYPES:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
RANGE TOLERANCE:
ON Delay
±1% of setting
50 msec minimum
1.5 cycles (60Hz) to 300 sec in 8 ranges
≤10% of setting
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
HI-POT:
OUTPUT
TIMING
PHYSICAL
-40° to 65° C (-72° to 117° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
1500V terminals to case, 1200V between open contacts
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE 1017SP7
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
WIRING
OUTPUT A
A-B Voltage Input (control)
1-2 N.C. timed(1 positive)
3-4 N.O. timed(4 positive)
DIMENSIONS inch (mm)
Wiring Terminal Location
OUTPUT B
A-B Voltage Input (control)
2-1 N.C. timed(2 positive)
2-2 N.O. timed(2 positive)
D-4 N.C. timed(D positive)
D-C N.O. timed(D positive)
In DC applications indicated
polarity provides optimum
arc suppression.
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1017SP7
INPUT VOLTAGE
D
A
B
C
TIME RANGE (secs)
1
2
3
4
7
8
9
10
OUTPUT
A
B
1017SP7 - B - 9 - B
24 V AC/DC
48 V AC/DC
120 VAC/125 VDC
240 VAC/250VDC
1.5 - 30 cycles (60Hz)
1.5 - 45 cycles (60Hz)
1.5 - 60 cycles (60Hz)
1.5 - 120 cycles (60Hz)
0.5 - 30 seconds
0.5 - 60 seconds
0.5 - 120 seconds
0.5 - 300 seconds
Relay 1 N.O. & 1 N.C.
Relay DPDT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1018
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Reliable plug-in timer available in three timing functions.
Features:
•Time ranges from 0.06 to 1000 sec.
•120 or 24 V AC/DC input.
•10 amp relay output.
•Remote adjustable (only output 2).
U
UL File No. E50957
TIMING
OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When control turns off, the delay starts and output
turns off after time elapses.
PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on. Output
remains on while delay time elapses.
• Turning control on and off during delay time has no
effect on the output or timing.
INTERVAL
• Control is affected with power application.
• When power is applied, output turns on and remains
on till delay time is elapsed.
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
INPUT
120VAC/DC, 24VAC/DC
50/60Hz or DC
±10% of nominal
3VA maximum
MOV
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1018
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS con't
TYPE:
RATING:
OUTPUT
Electromechanical relay
10A @ 240VAC
TIMING
AVAILABLE TYPES:
OFF Delay, Pulse Interval*, Interval
* Standard unit shipped as an OFF Delay. Remove jumper clip (see dimensions) for Pulse Interval.
REPEAT ACCURACY:
±1% of setting or 8 msecs, whichever is greater
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
5-6 (Standard), 2-7 (Option 13)
VOLTAGE PRESENT AT CONTROL TERMINALS:
70 VDC (120VAC/DC - Standard)
30VDC (24VAC - Standard), 24VDC (24VDC - Standard)
Same as input voltage (Option 13)
RESET TIME:
50 msec minimum - Standard only
100 msec minimum - Option 13
RANGE TOLERANCE:
≤30% of setting
INDICATE TIME:
5 msec minimum - Standard only
INDICATION:
LED - On when timing
TIMING RAMP:
0.06 sec minimum time - 1MΩ/sec
0.5 sec minimum time - 100kΩ/sec
5 sec minimum time - 10kΩ/sec
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum or 8 msec, whichever is greater (up to 500 seconds)
Plug-in
8 or 11-pin socket
Plastic
WIRING
OUTPUT 1
2-10 Voltage Input
(constant)
1-3 N.O. timed
1-4 N.C. timed
11-9 N.O. timed
11-8 N.C. timed
5-6 Control
7
Not used
Caution: Never apply
voltage to 5-6
OUTPUT 2
2-10 Voltage Input
(constant)
1-3 N.O. timed
1-4 N.C. timed
8-9 Remote adjust
5-6 Control
7-11 Not used
Caution: Never apply
voltage to 5-6-8-9
OPTION 13 (Output 1 only)
Maintained Interval
1-4 N.C. timed
2-7 Voltage Input
(control)
8-5 N.C. timed
8-6 N.O. timed
Wiring Terminal Location
8
6
5
7
7
8
9 10 11
4
3
1
2
5
4
2
3
6
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1018
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
DIMENSIONS inch (mm)
ORDERING DATA
ORDERING CODE
1018 - M - 1
----
BASIC MODEL NUMBER
1018
TIME RANGE (secs)
A 0.06 - 1.0
J 5 - 1000
B 0.5 - 10.0
L 0.06 - 2.5
C 5 - 100
M 0.5 - 25.0
D 5 - 250
N 0.5 - 50.0
E 5 - 500
R 0.06 - 5.0
OUTPUT
1
Relay DPDT
(11 pin plug standard, 8 pin plug for OP13)
2
Relay SPDT with remote adjust (11 pin plug)
OPTION (If desired)
OP4
24 VDC input
OP13
Interval timing function - Only available with 8 pin plug and output 1.
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
8 pin socket
11 pin socket
Hold down clip
RP-207 thru RP-210
RP-216
RP-217
RP-302
RP-303
RP-305
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1019
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Economical timer plugs into 11 position relay socket.
Features:
•Power control ON delay.
•Time ranges from 0.02 to 500 seconds.
•120 V AC/DC input.
•10 amp relay output.
•Remote adjustable (only output 3).
U
UL File No. E50957
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
timed output turns on.
•The timed output remains on until the unit is reset
by removing power.
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC/DC
50/60Hz or DC
±10% of nominal
3VA maximum
MOV
TYPE:
RATING:
Electromechanical relay
10A @ 240VAC
OUTPUT
TIMING
AVAILABLE TYPES:
ON Delay
REPEAT ACCURACY:
±1% of setting
CONTROL:
Application of power initiates timing cycle.
CONTROL TERMINALS:
A-B
VOLTAGE PRESENT AT CONTROL TERMINALS: Same as input voltage.
RESET TIME:
40 msec minimum
RANGE TOLERANCE:
≤30% of setting
TIMING RAMP:
0.02 sec minimum time - 1MΩ/sec
0.6 sec minimum time - 100kΩ/sec
0.5 sec minimum time - 10kΩ/sec
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1019
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 50° C (32° to 120° F)
±5% maximum
Plug-in
11-pin blade socket
Plastic
WIRING
OUTPUT 1
A-B Voltage Input
4-7
N.O. timed
1-7
N.C. timed
6-9
N.O. timed
3-9
N.C. timed
2-5-8 Not used
OUTPUT 3
A-B Voltage Input
4-7 N.O. timed
1-7 N.C. timed
6-9 N.O. timed
3-9 N.C. timed
2-5 Remote adjust
(jumper if not
used)
8
Not used
OPTION 4
A-B Voltage Input
1-7 N.C. timed
4-7 N.O. timed
3-9 N.C. timed
6-9 N.O. timed
2-8 N.C. timed
5-8 N.O. timed
Caution: Never apply
voltage to 2-5
Wiring Terminal Location
11-pin Blade Socket
6
5
4
3
2
1
B
9
A
8
7
DIMENSIONS inch (mm)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1019
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1019
TIME RANGE (secs)
1
5
10
50
100
500
OUTPUT
1
3
4
INPUT
1
1019 - 1 - 4 - 2
0.02 - 1.0
0.02 - 5.0
0.06 - 10.0
0.06 - 50.0
0.5 - 100
0.5 - 500
Relay DPDT
Relay DPDT with remote adjust
Relay 3PDT
120 V AC/DC
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
11 pin socket
Hold down clip
RP-207 thru RP-210
RP-216
RP-304
RP-306
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1020
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ON Delay timer for electric utility motor over-run
applications.
Features:
•Input power initiates the timing sequence.
•High voltage DC switching capablity.
•Factory fixed delay from 0.5 sec. to 20 min.
•Reset button and LED indicating energized output
•Equipped with transient voltage protection.
•Metal housing to maximize noise immunity.
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset by
removing power or pressing reset button.
SPECIFICATIONS
VOLTAGE:
INPUT
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
24VAC/DC, 48VAC/DC,
120VAC/125VDC,
240VAC/250VDC
±15% of nominal, ±10% for 24V
16W maximum
TVS Diode
TYPE:
RATING:
Electromechanical relay
3A @ 150VDC maximum, 10A @ 240VAC 80% PF maximum
OUTPUT
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
TIME RANGE:
RESET TIME:
DELAY TOLERANCE:
ON Delay
±1%
Factory fixed to customer specifications from 0.5 sec. to 20 min.
50 msec minimum
≤10%
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1020
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS con't
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
HI-POT:
PHYSICAL
-40° to 65° C (-40° to 149° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
1500V terminals to case, 1200V between open contacts
WIRING
DIMENSIONS inch (mm)
Wiring Terminal Location
OUTPUT B
A-B Voltage Input
2-1 N.C. timed (2 positive)
2-3 N.O. timed (2 positive)
D-4 N.C. timed (D positive)
D-C N.O. timed (D positive)
In DC applications, indicated
polarity provides optimum arc
suppression.
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1020
INPUT VOLTAGE
D
A
B
C
TIME RANGE (secs)
W
1020 - B - W - B
24 V AC/DC
48 V AC/DC
120 VAC/125 VDC
240 VAC/250VDC
Factory fixed
(within 10% of customer specified time)
OUTPUT
B
Relay DPDT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1025
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ON Delay timer for electric utility motor over-run
applications.
Features:
•Input power initiates the timing sequence.
•High voltage DC switching capablity.
•6PDT relay output.
•Factory fixed delay from 0.5 sec. to 20 min.
•Reset button and LED indicating energized output
•Equipped with transient voltage protection.
•Metal housing to maximize noise immunity.
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset by
removing power or pressing reset button.
SPECIFICATIONS
VOLTAGE:
INPUT
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
48VAC/DC,
120VAC/125VDC,
240VAC/250VDC
±15% of nominal
16W maximum
TVS Diode
TYPE:
RATING:
Electromechanical relay
7 A @ 240 VAC maximum
AVAILABLE TYPES:
REPEAT ACCURACY:
TIME RANGE:
RESET TIME:
DELAY TOLERANCE:
ON Delay
±1%
Factory fixed to customer specifications from 0.5 sec to 20 min.
50 msec minimum
≤10%
OUTPUT
TIMING
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1025
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS con't
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
HI-POT:
PHYSICAL
-40° to 65° C (-40° to 149° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
1500V terminals to case, 1000V between open contacts
WIRING
DIMENSIONS inch (mm)
In DC applications,
OUTPUT C
indicated polarity provides
A-B Voltage Input
optimum arc suppression.
2-1 N.C. timed (2 positive)
2-3 N.O. timed (2 positive)
5-4 N.C. timed (5 positive)
5-6 N.O. timed (5 positive)
8-7 N.C. timed (8 positive)
8-9 N.O. timed (8 positive)
11-10 N.C. timed (11 positive)
11-12 N.O. timed (11 positive)
14-13 N.C. timed (14 positive)
14-15 N.O. timed (14 positive)
17-16 N.C. timed (17 positive)
17-18 N.O. timed (17 positive)
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1025
INPUT VOLTAGE
D
A
B
C
TIME RANGE (secs)
3
1025 - B - 3 - B
24 V AC/DC
48 V AC/DC
120 VAC/125 VDC
240 VAC/250VDC
Factory fixed (3 minutes)
(within 10% of customer specified time)
OUTPUT
C
Relay 6PDT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1026
Kanson Electronics, Inc.
TIMER
BASE MOUNT
I
ON Delay timer for electric utility applications.
Features:
•Input power initiates the timing sequence.
•High voltage DC switching capablity.
•6PDT relay output.
•Time ranges from 1.5 cycles (60Hz) to 300 seconds.
•Reset button and LED indicating energized output
•Equipped with transient voltage protection.
•Metal housing to maximize noise immunity.
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
•The output remains on until the unit is reset by
removing power or pressing reset button.
SPECIFICATIONS
VOLTAGE:
INPUT
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
48VAC/DC,
120VAC/125VDC,
240VAC/250VDC
±15% of nominal
16W maximum
TVS Diode
TYPE:
RATING:
Electromechanical relay
7 A @ 250 VAC maximum
AVAILABLE TYPES:
REPEAT ACCURACY:
TIME RANGE:
RESET TIME:
RANGE TOLERANCE:
ON Delay
±1% of setting
1.5 cycles (60Hz) to 300 sec in 8 ranges
50 msec minimum
≤10% of setting
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
HI-POT:
-40° to 65° C (-40° to 149° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
1500V terminals to case, 1000V between open contacts
OUTPUT
TIMING
PHYSICAL
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1026
Kanson Electronics, Inc.
TIMER
BASE MOUNT
I
WIRING
DIMENSIONS inch (mm)
In DC applications,
OUTPUT C
indicated polarity provides
A-B Voltage Input
optimum arc suppression.
2-1 N.C. timed (2 positive)
2-3 N.O. timed (2 positive)
5-4 N.C. timed (5 positive)
5-6 N.O. timed (5 positive)
8-7 N.C. timed (8 positive)
8-9 N.O. timed (8 positive)
11-10 N.C. timed (11 positive)
11-12 N.O. timed (11 positive)
14-13 N.C. timed (14 positive)
14-15 N.O. timed (14 positive)
17-16 N.C. timed (17 positive)
17-18 N.O. timed (17 positive)
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1026
INPUT VOLTAGE
A
B
C
TIME RANGE (secs)
1
2
3
4
7
8
9
10
OUTPUT
C
1026 - B - 4 - B
48 V AC/DC
120 VAC/125 VDC
240 VAC/250VDC
1.5 - 30 cycles (60Hz)
1.5 - 45 cycles (60Hz)
1.5 - 60 cycles (60Hz)
1.5 - 120 cycles (60Hz)
0.5 - 30 seconds
0.5 - 60 seconds
0.5 - 120 seconds
0.5 - 300 seconds
Relay 6PDT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1030
Kanson Electronics, Inc.
TIMER
BASE MOUNT
I
Dual time control timer available in three timing functions.
Features:
•External plug-in DPDT relay.
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120, 230 or 24 VAC input.
•10 amp relay output.
•Remote adjust capability.
•Output energized indication LED
TIMING
PULSE ONE CYCLE
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• The ON time then starts and output turns back off
once time has elapsed.
• Turning control on and off during delay time has
no effect on the output or timing.
ONE CYCLE
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• The ON time then starts and output turns back
off once time has elapsed.
• When control turns off; unit resets.
ON DELAY / OFF DELAY
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• When the control turns off, the ON time starts
and output turns off after time elapses.
• If control turns off while output is off; unit resets
immediately.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1030
Kanson Electronics, Inc.
TIMER
BASE MOUNT
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC, 24VAC, 240VAC
50/60Hz
±15% of nominal
10VA maximum
Isolated transformer (120VAC and 240VAC only)
TYPE:
RATING:
Electromechanical relay
10A @ 240VAC maximum
OUTPUT
TIMING
AVAILABLE TYPES:
Pulse One Cycle, One Cycle, ON Delay / OFF Delay
INDICATION:
LED - On when output energized
REPEAT ACCURACY:
±1% of setting
TIME RANGE:
0.06 to 500 seconds in 9 ranges
TIME RAMP:
0.06 sed. min. time - 100kΩ/sec., 0.5 sec. min. time - 10kΩ/sec.
RESET TIME:
50 msec minimum
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
E-F
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC minimum, 40VDC maximum
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 55° C (32° to 131° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
DIMENSIONS inch (mm)
WIRING
Wiring Terminal Location
OUTPUT B
A-B Voltage Input (contant)
6
C-D Remote adjust for OFF time, 7
A
H
5
(jumper if not used)
8
G
B
E-F Control
F
C
4
1
(starts timing function)
D
E
2
3
G-H Remote adjust for ON time,
(jumper if not used)
1-3 N.O. timed
1-4 N.C. timed
5-8 N.C. timed
6-8 N.O. timed
Caution: Nevery apply voltage
to C-D-E-F-G-H
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1030
Kanson Electronics, Inc.
TIMER
BASE MOUNT
I
ORDERING DATA
ORDERING CODE
1030 - 1 - E - E - 6 - B
BASIC MODEL NUMBER
1030
INPUT VOLTAGE
1
2
3
TIME RANGE (secs)
120 VAC
240 VAC
24 VAC
Off time
On time
ON and OFF delay time ranges must have the same minimum time.
D
0.06 - 1.0
E
0.06 - 2.5
F
0.06 - 5.0
G
0.06 - 10.0
H
0.06 - 25.0
J
0.5 - 50.0
K
0.5 - 100
L
0.5 - 250
M
0.5 - 500
TIMING FUNCTION
6
Pulse One Cycle
7
One Cycle
8
ON Delay / OFF Delay
OUTPUT
B
Relay DPDT
APPLICABLE ACCESSORIES
See accesory section for details
Output modules
Potentiometers
Reference dial
Locking attachment
RP-101
RP-201 thru RP-210
RP-216
RP-217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1032
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Dual time control timer available in three timing functions.
Features:
•12 plug-in base - socket included.
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120 or 24 VAC input.
•10 amp relay output.
•Remote adjust capability (Off delay only).
•Output energized indication LED
TIMING
PULSE ONE CYCLE
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• The ON time then starts and output turns back off
once time has elapsed.
• Turning control on and off during delay time has
no effect on the output or timing.
ONE CYCLE
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• The ON time then starts and output turns back
off once time has elapsed.
• When control turns off; unit resets.
ON DELAY / OFF DELAY
• Control is independent of unit power.
• When control turns on, OFF time elapses before
output turns on.
• When the control turns off, the ON time starts
and output turns off after time elapses.
• If control turns off while output Is on; unit resets
immediately.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1032
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
INPUT
120VAC/DC, 24VAC/DC
50/60Hz
±15% of nominal
10VA maximum
Isolated transformer (120VAC only)
OUTPUT
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay
10,000,000 operations
300,000 operations
10A @ 240VAC maximum
TIMING
AVAILABLE TYPES:
INDICATION:
REPEAT ACCURACY:
TIME RANGE:
TIME RAMP:
Pulse One Cycle, One Cycle, ON Delay / OFF Delay
LED - On when output energized
±1% of setting
DIMENSIONS
0.06 to 500 seconds in 9 ranges
0.06 sed. min. time - 100kΩ/sec.,
0.5 sec. min. time - 10kΩ/sec.
RESET TIME:
50 msec minimum
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
5-6
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC min., 40VDC max.
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
inch (mm)
PHYSICAL
0° to 55° C (32° to 131° F)
±5% maximum
Plug-in
12-pin socket
Metal
WIRING
OUTPUT B
1-2
Voltage Input
(constant)
3-4
Remote Adjust, ON time
(jumper not when used)
5-6
Control
(starts timing function)
7-8
N.O. timed
8-9
N.O. timed
10-11 N.C. timed
11-12 N.C. timed
Wiring Terminal Location
12-Pin Socket
Caution: Never apply voltage
to terminals 3-4-5-6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1032
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
1032 - 1 - H - H - 8 - B
BASIC MODEL NUMBER
1032
INPUT VOLTAGE
1
2
TIME RANGE (secs)
120 VAC
24 VAC
OFF time
ON time
ON and OFF delay time ranges must have the same minimum time.
B
0.06 - 0.25
C
0.06 - 0.50
D
0.06 - 1.0
E
0.06 - 2.5
F
0.06 - 5.0
G
0.06 - 10.0
H
0.06 - 25.0
J
0.5 - 50.0
K
0.5 - 100
L
0.5 - 250
M
0.5 - 500
TIMING FUNCTION
6
Pulse One Cycle
7
One Cycle
8
ON Delay / OFF Delay
OUTPUT
B
Relay DPDT
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
12 pin socket (included)
RP-201 thru RP-210
RP-216
RP-217
RP-301
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1060
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
Dual time control timer available in two timing functions.
Features:
•External plug-in DPDT relay.
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120, 230 or 24 VAC input.
•10 amp relay output.
•Remote adjust capability.
•Output energized indication LED
TIMING
REPEAT CYCLE START OFF
• Control is independent of unit power.
• When control turns on, the output remains off
while OFF time elapses. The output then turns on
while ON time elapses.
• This cycle then repeats until power is removed
from the unit or control turns off.
REPEAT CYCLE START ON
• Control is independent of unit power.
• When control turns on, the output turns on while
ON time elapses. The output then turns back off
while OFF time elapses.
• This cycle then repeats until power is removed
from the unit or control turns off.
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC
50/60Hz
±15% of nominal
10VA maximum
Isolated transformer
TYPE:
RATING:
Electromechanical relay (Solid State available as accessory)
10A @ 240VAC maximum
OUTPUT
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1060
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS con't
TIMING
AVAILABLE TYPES:
Repeat Cycle (start ON or start OFF)
INDICATION:
LED - On when output energized
REPEAT ACCURACY:
±1% of setting
TIME RANGE:
0.06 to 500 seconds in 9 ranges
TIME RAMP:
0.06 sed. min. time - 100kΩ/sec., 0.5 sec. min. time - 10kΩ/sec.
RESET TIME:
50 msec minimum
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
E-F
VOLTAGE PRESENT AT CONTROL TERMINALS: 24VDC minimum, 40VDC maximum
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 55° C (32° to 131° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
DIMENSIONS inch (mm)
WIRING
OUTPUT B
A-B Voltage Input (contant)
C-D Remote adjust for first
time period
(jumper if not used)
E-F Control
(starts timing function)
G-H Remote adjust for second
time period
(jumper if not used)
1-3 N.O. timed
1-4 N.C. timed
5-8 N.C. timed
6-8 N.O. timed
Wiring Terminal Location
7
8
1
2
A
B
C
D
H
G
F
E
6
5
4
3
Caution: Nevery apply voltage
to C-D-E-F-G-H
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1060
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
1060 - 1 - D - D - 2 - B
BASIC MODEL NUMBER
1060
INPUT VOLTAGE
1
TIME RANGE (secs)
120 VAC
ON time
OFF time
ON and OFF delay time ranges must have the same minimum
D
0.06 - 1.0
E
0.06 - 2.5
F
0.06 - 5.0
G
0.06 - 10.0
H
0.06 - 25.0
J
0.5 - 50.0
K
0.5 - 100
L
0.5 - 250
M
0.5 - 500
TIMING FUNCTION
1
Repeat Cycle Start ON
2
Repeat Cycle Start OFF
OUTPUT
B
Relay DPDT
APPLICABLE ACCESSORIES
See accesory section for details
Output modules
Potentiometers
Reference dial
Locking attachment
time.
RP-101
RP-201 thru RP-210
RP-216
RP-217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1061
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
Totally solid state dual timer available in two timing functions.
Features:
•Timing control contacts independent of unit input power.
•Time ranges from 0.06 to 500 seconds.
•120 VAC input.
•35 VA output @ input voltage.
•Optional timing indication light.
TIMING
REPEAT CYCLE START OFF
• Control is independent of unit power.
• When control turns on, the output remains off
while OFF time elapses. The output then turns on
while ON time elapses.
• This cycle then repeats until power is removed
from the unit or control turns off.
REPEAT CYCLE START ON
• Control is independent of unit power.
• When control turns on, the output turns on while
ON time elapses. The output then turns back off
while OFF time elapses.
• This cycle then repeats until power is removed
from the unit or control turns off.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1061
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TYPE:
RATING:
120VAC
50/60Hz
±15% of nominal
10VA maximum
OUTPUT
Solid State
35VA continuous, 150VA in-rush @ 120VAC
TIMING
AVAILABLE TYPES:
Repeat Cycle (start ON or start OFF)
INDICATION:
Optional incadescent light - On when output energized
TIME RANGE:
0.06 to 500 seconds in 9 ranges
TIME RAMP:
0.06 sec. min. time - 100kΩ/sec., 0.5 sec. min. time - 10kΩ/sec.
RANGE TOLERANCE:
≤10% of setting
CONTROL:
Isolated contact closure
CONTROL TERMINALS:
E-F
VOLTAGE PRESENT AT CONTROL TERMINALS: Same as input voltage
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
0° to 55° C (32° to 131° F)
±5% maximum
Base Mount
Terminal blocks on face of timer
Metal
WIRING
A-B Voltage input
(constant)
E-F Control
(starts timing function)
B-2 N.O. timed output
DIMENSIONS inch (mm)
Wiring Terminal Location
A
B
2
E
F
Caution: Never apply voltage
E-F
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1061
BASE MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
1061 - 1 - G - G - 2 - C
---
BASIC MODEL NUMBER
1061
INPUT VOLTAGE
1
TIME RANGE (secs)
120 VAC
ON time
OFF time
ON and OFF delay time ranges must have the same minimum time.
D
0.06 - 1.0
E
0.06 - 2.5
F
0.06 - 5.0
G
0.06 - 10.0
H
0.06 - 25.0
J
0.5 - 50.0
K
0.5 - 100
L
0.5 - 250
M
0.5 - 500
TIMING FUNCTION
1
Repeat Cycle Start ON
2
Repeat Cycle Start OFF
OUTPUT
C
Solid State (AC) 1 N.O. 35VA
OPTION (if desired)
OP6
Timing indication light
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
RP-201 thru RP-210
RP-216
RP-217
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1068
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
Dual time control repeat cycle timer.
Features:
•Input power initiates the timing sequence.
•Time ranges from 0.1 to 500 seconds.
•100-240 VAC, 24 V AC/DC or 12 VDC input.
•5 amp relay output.
•Output indication LEDs.
U
TIMING
C
REPEAT CYCLE
• Control is affected with power application.
• When power turns on, the output remains off while
OFF time elapses.
• The output then turns on while ON time elapses.
• This cycle then repeats until power is removed
from the unit.
SPECIFICATIONS
TIMING
AVAILABLE TYPES:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
Repeat Cycle
±0.3% of setting
300 msec minimum
0.1 secs to 500 hours in 16 ranges
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
100-240VAC, 24VAC/DC, 12VDC
50/60Hz (AC Models)
-10% to 15% of nominal
10VA (100-240VAC), 2.5VA (24VAC), 2W (12VDC & 24VDC)
MOV
INPUT
OUTPUT
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay
20,000,000 operations
100,000 operations minimum (at full rated load)
5A @ 240VAC (resistive)
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
DEGREE OF PROTECTION:
-10° to 50° C (14° to 122° F)
±2% maximum
Plug-in or panel mount
8-pin socket or screw terminals
Polycarbonate
IP50 (standard), IP65 (special)
PHYSICAL
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1068
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
WIRING
DIMENSIONS inch (mm)
MOUNTING mm
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
DIN RAIL MOUNT
8 Pin socket RP320 has built in
hold down clips
and is DIN rail
compatible.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1068
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1068
INPUT VOLTAGE
1
2
3
TIME RANGE
P
secs
0.1-1.0
0.5-5.0
1.0-10
5.0-50
TIMING FUNCTION
9
OUTPUT
B
TERMINATION
1
2
DEGREE OF PROTECTION
1
2
1068 - 1 - P - 9 - B - 1 - 1
100-240 VAC
24 V AC/DC
12 VDC
mins
0.1-1.0
0.5-5.0
1.0-10
5.0-50
hrs
0.1-1.0
0.5-5.0
1.0-10
5.0-50
10 hrs
1.0-10
5.0-50
10-100
50-500
Repeat Cycle
Relay DPDT
8 pin plug-in base
Screw terminals
IP50 Standard
IP65 Sealed unit
APPLICABLE ACCESSORIES
See accesory section for details
8 pin socket
8 pin reversible socket
8 pin cable socket
Panel mount clip
Stop rings
RP-320
RP-321
RP-323
RP-325
RP-327
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1071
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Multi time range ON delay timer.
Features:
•Input power initiates timing sequence.
•Selectable time ranges from 0.025 to 2000 sec.
•120 VAC or 24 V AC/DC input.
•5 amp relay output.
•Remote adjustable (only output A & C).
U
UL File No. E50957
C CSA File No. LR92518
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset by
removing power.
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
TYPE:
RATING:
INPUT
120VAC/DC, 24VAC/DC
50/60Hz or DC
15% of nominal
4VA maximum
MOV
OUTPUT
Electromechanical relay
5A @ 240VAC maximum
TIMING
AVAILABLE TYPES:
ON Delay
REPEAT ACCURACY:
±0.5% of setting or 0.004 seconds, whichever is greater
RESET TIME:
40 msec minimum
TIME RATIO:
10 to 1 potentiometer
TIME RANGE:
8 per unit
INDICATION:
LED - ON when timing
RANGE TOLERANCE:
≤10% typical
CONTROL:
Power actuated or AC proximity sensor
CONTROL TERMINALS:
2-7 (8-pin unit), 2-10 (11-pin unit)
VOLTAGE PRESENT AT CONTROL TERMINALS: Same as input voltage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1071
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS con't
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
PHYSICAL
-20° to 70° C (-4° to 158° F)
±5% maximum
Plug-in
8- or 11-pin socket
Plastic
WIRING
OUTPUT A
2-7 Voltage input (control)
1-3 N.O. timed
1-4 N.C. timed
5-6 Remote adjust
8
Not used
Caution: Never apply
voltage to 5-6
OUTPUT C
2-7 Voltage input (control)
1-3 N.O. timed
1-4 N.C. timed
11-9 Remote adjust
6
5
4
3
7
8
1
2
OUTPUT B
2-7 Voltage input (control)
1-3 N.O. timed
1-4 N.C. timed
8-6 N.O. timed
8-5 N.C. timed
8
7
9
10
6
5
4
2
3
11-8 N.C. timed
5-6 Remote adjust
7
Not used
Caution: Never apply voltage to 5-6
11
1
DIMENSIONS inch (mm)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1071
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
1071 - 1 - P - 1 - B
BASIC MODEL NUMBER
1071
INPUT VOLTAGE
1
120 VAC
2
24 V AC/DC
TIME RANGE (secs)
P (switch positions as follow)
0 200-2000
5 0.2-2.0
1 50-500
6 0.06 - 0.5
2 12-120
7 0.025 - 0.13
3 3.0-30
8 not used
4 0.75-7.5
9 not used
TIMING FUNCTION
1
ON Delay
OUTPUT
A
Relay SPDT - remote adjust (8 pin plug)
B
Relay DPDT (8 pin plug)
C
Relay DPDT - remote adjust (11 pin plug)
(Remote adjust units require an external 100k Potentiometer - RP-204.)
APPLICABLE ACCESSORIES
See accesory section for details
Potentiometers
Reference dial
Locking attachment
8 pin socket
11 pin socket
Hold down clip
RP-204
RP-216
RP-217
RP-302
RP-303
RP-305
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1073
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Multifunction timer with instant contacts or ON delay timer.
Features:
•5 timing functions.
•Input power initiates the timing sequence.
•Time ranges from 0.1sec to 500 hr.
•100-240 VAC, 24 V AC/DC or 12 VDC input.
•5 amp relay output.
•Power and output indication LEDs.
U
C
TIMING
ON DELAY - output B
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset by
removing power.
ON - ON DELAY - output A
• Control is affected with power application.
• When power turns on, delay time elapses before
timed output turns on.
• The timed output remains on until the unit is reset
by removing power.
• Instant output directly follows control input.
FL - REPEAT CYCLE START OFF - output A
• Control is affected with power application.
• When power turns on, the output remains off while
time elapses.
• The output then turns on while time elapses.
• This cycle then repeats until power is removed
from the unit.
• Instant output directly follows control input.
FO - REPEAT CYCLE START ON - output A
• Control is affected with power application.
• When power turns on, the output turns on while
delay time elapses.
• The output then turns off while delay time elapses
• This cycle then repeats until power is removed
from the unit.
• Instant output directly follows control input.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1073
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
OS - INTERVAL - output A
• Control is affected with power application.
• When power is applied, timed output turns on and
remains on till delay time is elapsed or power is
removed.
• Instant output directly follows control input.
OC - ONE CYCLE - output A
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
• The delay then restarts and output turns back off
once delay time has elapsed.
• Instant output directly follows control input.
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
100-420VAC, 24VAC/DC, 12VDC
50/60Hz (AC Models)
-15% to +10% of nominal
10VA (100-240VAC), 2.5VA (24VAC), 2W (12VDC & 24VDC)
MOV
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay
20,000,000 operations
100,000 operations minimum (at full rated load)
5A @ 240VAC (resistive)
TYPE:
Output B:
Output A:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
±0.3% of setting
100 msec minimum
0.01 to 500 hours in 16 ranges
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
DEGREE OF PROTECTION:
-10° to 50° C (-14° to 122° F)
±2% maximum
Plug-in or Panel Mount
8-pin socket or screw terminals
Polycarbonate
IP50 (standard, IP65 (special)
OUTPUT
TIMING
On Delay only
On Delay, Repeat Cycle Start Off,
Repeat Cycle Start On, Interval, One Cycle
PHYSICAL
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1073
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
WIRING
OUTPUT A
Instant
Timed
Instant
Timed
*Polarity indicated for
DC Models only.
OUTPUT B
*Polarity indicated for
DC Models only.
DIMENSIONS inch (mm)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1073
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
MOUNTING mm
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
DIN RAIL MOUNT
8 Pin socket RP320 has built in
hold down clips
and is DIN rail
compatible.
ORDERING DATA
ORDERING CODE
1073 - 1 - P - 2 - A - 1 - 1
BASIC MODEL NUMBER
1073
INPUT VOLTAGE
1
100-240 VAC
2
24 V AC/DC
3
12 VDC
TIME RANGE
P
secs
mins
hrs
10 hrs
0.1-1.0
0.1-1.0
0.1-1.0
1.0-10
0.5-5.0
0.5-5.0
0.5-5.0
5.0-50
1.0-10
1.0-10
1.0-10
10-100
5.0-50
5.0-50
5.0-50
50-500
TIMING FUNCTION and OUTPUT
1-B
ON Delay with DPDT relay
2-A
ON Delay, Repeat Cycle, Inteval, One Cycle
Timed relay SPDT and Instant relay SPDT
TERMINATION
1
8 pin plug-in base
2
Screw terminals
DEGREE OF PROTECTION
1
IP50 Standard
2
IP65 Sealed unit
APPLICABLE ACCESSORIES
See accesory section for details
8 pin socket
8 pin reversible socket
8 pin cable socket
Panel mount clip
Stop rings
RP-320
RP-321
RP-323
RP-325
RP-327
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1081
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
True Off Delay timer.
Features:
•Input power initiates the timing sequence.
•Time ranges from 0.04 sec to 10 min.
•12 to 240 volt inputs in 5 options.
•3 amp relay output.
•Power indication LEDs.
U
C
TIMING
TRUE OFF DELAY
• Control is affected with power application.
• When power turns on, the output turns on.
• When power turns off, a capacitor, which charges in
less than 100 ms, maintains output on while the delay
time elapses.
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
INPUT
100-120VAC, 200-240VAC,
24VAC, 24VDC, 12VDC
50/60Hz (AC Models)
-15% to +10% of nominal
5VA (AC Models), 2W (DC Models)
MOV
OUTPUT
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay
10,000,000 operations
100,000 operations minimum (at full rated load)
3A @ 240VAC (resistive)
TYPE:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
True OFF Delay
±0.3% of setting
100 msec minimum at maximum time setting
0.04 seconds to 10 seconds or 0.04 minutes to 10 minutes
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
DEGREE OF PROTECTION:
-10° to 50° C (-14° to 122° F)
±2% maximum
Plug-in or Panel Mount
8-pin socket
Polycarbonate
IP50 (standard), IP65 (special)
TIMING
PHYSICAL
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1081
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
WIRING
DIMENSIONS inch (mm)
Model 1081 is not
available with
screw terminals dimensions shown
for model 1090 only.
MOUNTING mm
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
DIN RAIL MOUNT
8 Pin socket
RP-320 has built
in hold down clips
and is DIN rail
compatible.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1081
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1081
INPUT VOLTAGE
1
2
3
4
5
TIME RANGE
A
1081 - 1 - B - 2 - B - 1
120 VAC
240 VAC
24 VAC
24 VDC
12 VDC
0.04 - 1.0 sec
0.2 - 5.0 sec
0.4 - 10 sec
B
0.04 - 1.0 min
0.4 - 10 min
0.2 - 5.0 min
TIMING FUNCTION
2
OUTPUT
B
DEGREE OF PROTECTION
1
2
OFF Delay
Relay DPDT
IP50 Standard
IP65 Sealed unit
APPLICABLE ACCESSORIES
See accesory section for details
8 pin socket
8 pin reversible socket
8 pin cable socket
Panel mount clip
Stop rings
RP-320
RP-321
RP-323
RP-325
RP-327
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INDUSTRIAL SOLID STATE MODEL 1090
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
Multifunction timer with single time control.
Features:
•8 timing functions.
•Control, stop and reset contacts independent of unit power.
•Time ranges from 0.1sec to 500 hr.
•100-240 VAC, 24 V AC/DC or 12 VDC input.
•5 amp relay output.
•Power and output indication LEDs.
U
C
TIMING
ON - PULSE ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset either
by removing power or applying independent reset
control.
• Turning control on and off during delay time has no
effect on the output or timing.
(t1 + t2 = DELAY)
FL - PULSE REPEAT CYCLE START OFF
• Control is independent of unit power.
• When control turns on, the output remains off while
delay time elapses.
• The output then turns on and remains on while
delay time elapses.
• This cycle then repeats until power is removed from
the unit or independent reset control is applied.
• Turning control on and off while cycling has no
effect on the output or timing.
(ta<DELAY; tb<DELAY; t1 + t2 = DELAY)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INDUSTRIAL SOLID STATE MODEL 1090
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
FO - PULSE REPEAT CYCLE START ON
• Control is independent of unit power.
• When control turns on, the output turns on while
delay time elapses.
• The output then turns back off while delay time
elapses.
• This cycle then repeats until power is removed from
the unit or independent reset control is applied.
• Turning control on and off while cycling has no
effect on the output or timing.
(ta<DELAY; tb<DELAY; t1+t2=DELAY)
OF1 - MOTION DETECT
• Control is independent of unit power.
• When control changes, output turns on and delay
time elapses before output returns to normal.
• If control changes during the delay time period, the
output remains on and the delay time will restart.
(t1+t2=DELAY; ta<DELAY; tb<DELAY)
SF - OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When the control turns off, the delay starts and
output turns off after time elapses.
( ta +tb = DELAY)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INDUSTRIAL SOLID STATE MODEL 1090
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
OS - PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on.
• Output remains on while delay time elapses.
• Turning control on and off while cycling has no
effect on the output or timing.
(t1+t2=DELAY; ta<DELAY)
OF2 - NO DELAY / OFF DELAY
• Control is independent of unit power.
• When control changes, delay time elapses before
output changes state.
• If control changes during the delay time period, the
output changes state and the delay time restarts.
(t1+t2=DELAY; ta<DELAY; tb<DELAY)
OC - PULSE ONE CYCLE
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
• The output remains on ~0.8 seconds then turns
back off.
• Turning control on and off during delay time has no
effect on the output or timing.
(T2 = 0.8 sec; ta+tb=T1; tc+td=T2; t1<T1; t2<T2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INDUSTRIAL SOLID STATE MODEL 1090
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
TYPE:
INPUT
50/60Hz (AC Models)
-15% to +10% of nominal
10VA (100-240VAC), 2.5VA (24 VAC), 2W (12VDC & 24VDC)
MOV
OUTPUT
20,000,000 operations
100,000 operations minimum (at full rated load)
5A @ 240VAC (resistive)
TIMING
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
Multifunction programmable (Pulse ON Delay,
Repeat Cycle Start OFF, Repeat Cycle Start ON,
Motion Detect, OFF Delay, Pulse Interval
ON Delay / OFF Delay, Pulse One Cycle)
±0.3% of setting
100 msec minimum
0.1 seconds to 500 hours in 16 ranges
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
DEGREE OF PROTECTION:
-10° to 50° C (-14° to 122° F)
±2% maximum
Plug-in or Panel Mount
11-pin socket or screw terminals
Polycarbonate
IP50 (standard), IP65 (special)
PHYSICAL
WIRING
Control, Reset & Stop input is accomplished by
isolated contact closure between indicated terminals.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INDUSTRIAL SOLID STATE MODEL 1090
PLUG-IN
Kanson Electronics, Inc.
TIMER
I
DIMENSIONS & MOUNTING
Same as Model 1081
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1090
INPUT VOLTAGE
1
2
3
TIME RANGE
P
secs
0.1-1.0
0.5-5.0
1.0-10
5.0-50
TIMING FUNCTIONS
3
1090 - 1 - P - 3 - B - 1 - 1
100-240 VAC
24 V AC/DC
12 VDC
mins
0.1-1.0
0.5-5.0
1.0-10
5.0-50
hrs
0.1-1.0
0.5-5.0
1.0-10
5.0-50
10 hrs
1.0-10
5.0-50
10-100
50-500
Selectable
Pulse ON Delay, Pulse Repeat Cycle Start OFF,
Pulse Repeat Cycle Start ON, Motion Detect,
OFF Delay, Pulse Interval, ON Delay / OFF Delay,
Pulse One Cycle
OUTPUT
B
Relay DPDT
TERMINATION
1
2
DEGREE OF PROTECTION
1
2
11 pin plug-in base
Screw terminals
IP50 Standard
IP65 Sealed unit
APPLICABLE ACCESSORIES
See accessory section for details
11 pin socket
11 pin cable socket
Panel mount clip
Stop rings
RP-322
RP-324
RP-325
RP-327
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1094
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
Multifunction digital timer with single time control.
Features:
•8 timing functions.
•Control, stop and reset contacts independent of unit power.
•Time ranges from 0.001sec to 9,999 hr.
•100-240 VAC, 24 VAC or 12-24 VDC input.
•5 amp relay or open collector transistor output.
•EE-PROM memory - setting and elapsed delay.
U
C
TIMING
A - ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset either
by removing power or by applying the independant
reset input.
(t1+t2=DELAY)
A2 - ON DELAY
• Control is affected with power application.
• When control turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset by
applying the independent reset input.
• Elapsed time and output state are retained in
memory in the event of power or control interruption.
(t1+t2=DELAY; ta<DELAY)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1094
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
B - ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
timed output turns on.
• The timed output remains on until the unit is reset
either by removing power or control.
(t1+t2=DELAY)
C - OFF DELAY
• Control is independent of unit power.
• When control turns on, the output turns on.
• When control turns off, the delay starts and output
turns off after time elapses.
(ta+tb=DELAY)
D - PULSE INTERVAL
• Control is independent of unit power.
• When control turns on, the output turns on.
• Output remains on while delay time elapses.
• Turning control on and off during delay time has no
effect on the output or timing.
(t1+t2=DELAY; ta<DELAY)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1094
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
E - PULSE ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
• The output remains on until the unit is reset either
by removing power or applying independent reset
input.
• Turning control on and off during delay time has no
effect on the output or timing.
(t1+t2=DELAY)
F - PULSE REPEAT CYCLE
• Control is independent of unit power.
• When control turns on, the output remains off while
delay time elapses.
• The output then turns on while delay time elapses.
• This cycle then repeats until power is removed from
the unit or independent reset control is applied
• Turning control on and off while cycling has no
effect on the output or timing.
(ta<DELAY; tb<DELAY; t1+t2=DELAY;)
G - TOTALIZED ON DELAY
• Control is independent of unit power.
• When control turns on, delay time elapses before
output turns on.
• Elapsed time totalizes through interuptions in
control.
• The output remains on until the unit is reset either
by removing power or applying the independent reset
control.
• Elapsed time and output state are retained in
memory in the event of a control interruption.
(t1+t2+t3=DELAY; ta<delay)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1094
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
POWER CONSUMPTION:
TRANSIENT PROTECTION:
100-240 V AC/DC, 24 VAC, 12-24 VDC
50/60Hz (AC Models)
2.5VA (AC Models), 2W (DC Models)
MOV
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
Electromechanical relay or transistor
10,000,000 operations (Relay only)
Relay - 100,000 operations minimum (at full rated load)
Transistor - 10,000,000 operations min.
5A @ 240VAC (resistive)
TYPE:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
Multifunction
±0.005% of setting
20 msec
0.001 seconds to 9999 hours
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
-10° to 50° C (-14° to 122° F)
±0.005%
Plug-in or Panel Mount
11-pin socket
Polycarbonate
OUTPUT
TIMING
PHYSICAL
WIRING
*Polarity
indicated for DC
models only
DIMENSIONS inch (mm)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1094
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
MOUNTING mm
DIN RAIL MOUNT
11 Pin socket
RP-322 has built
in hold down
clips and is DIN
rail compatible.
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
ORDERING DATA
ORDERING CODE
1094 - 1 - P - 3 - A
BASIC MODEL NUMBER
1094
INPUT VOLTAGE
1
100-240 VAC
2
12-24 VDC
3
24 VAC
TIME RANGE
P
0.001 sec to 9,999 hr
TIMING FUNCTIONS
3
Selectable
A
A2
B
C
D
E
F
G
ON Delay - Power Control
ON Delay - Power Control - Memory*
ON Delay
OFF Delay
Pulse Interval
Pulse ON Delay
Pulse Repeat Cycle
ON Delay - Totalizing
* A2 retains elapsed time during power off periods
OUTPUT
A
C
Relay SPDT
Open collector transistor
APPLICABLE ACCESSORIES
See accesory section for details
11 pin socket
11 pin cable socket
Panel mount clip
Protective cover
RP-322
RP-324
RP-325
RP-326
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1096
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
Multifunction digital timer with dual time control.
Features:
•6 timing functions.
•Control, stop and reset contacts independent of unit power.
•Time ranges from 0.001sec to 9,999 hr.
•100-240 VAC, 24 VAC or 12-24 VDC input.
•5 amp relay or open collector transistor output.
•EE-PROM memory - setting and elapsed delay.
U
C
TIMING
PULSE A - ONE CYCLE
• Control is independent of unit power.
• When control turns on, T1 delay time elapses before
output turns on.
• The T2 delay then starts and output turns back off
once time has elapsed.
• Turning control on and off during delay time has no
effect on the output or timing.
(ta+tb=T1; tc+td=T2; t1<T1; t2<T2)
PULSE B - REPEAT CYCLE START OFF
• Control is independent of unit power.
• When control turns on, the output remains off while
T1 delay time elapses.
• The output then turns on while T2 delay time
elapses.
• This cycle then repeats until power is removed from
the unit or independent reset control is applied.
• Turning control on of off while cycling has no effect
on the output or timing.
(ta+tb=T1; tc+td=T2; t1<T1; t2<T2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1096
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
PULSE C - REPEAT CYCLE START ON
• Control is independent of unit power.
• When control turns on, the output turns on while T1
delay time elapses.
• The output then turns back off while T2 delay time
elapses.
• This cycle then repeats until power is removed from
the unit or independent reset control is applied.
• Turning control on and off while cycling has no
effect on the output or timing.
(ta+tb=T1; tc+td=T2; t1<T1; t2<T2)
TOTAL A - ONE CYCLE
• Control is independent of unit power.
• When control turns on, T1 delay time elapses before
output turns on.
• The T2 delay time then starts and output turns back
off once time has elapsed.
• Elapsed time and output state are retained in
memory in the event of power or control interruption.
(ta+tb=T1; tc+td=T2; te+tf=T1; tg+th=T2; t1<T1;
t2<T2)
TOTAL B - REPEAT CYCLE START OFF
• Control is independent of unit power.
• When control turns on, the output turns on while T1
delay time elapses.
• The output then turns on while T2 delay time
elapses.
• This cycle then repeats until an independent reset
signal is applied.
• Elapsed time and output state are retained in
memory in the event of power or control interruption.
(ta+t2=T1; tc+td=T2; te+tf=T1; tg+th=T2; t1<T1;
t2<T2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1096
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
TIMING (cont)
TOTAL C - REPEAT CYCLE START ON
• Control is independent of unit power.
• When control turns on, T1 delay time elapses before
output turns on.
• The output turns back off while T2 delay time
elapses.
• This cycle then repeats until an independent reset
signal is applied.
• Elapsed time and output state are retained in
memory in the event of power or control interruption.
(ta+t2=T1; tc+td=T2; te+tf=T1; tg+th=T2; t1<T1;
t2<T2)
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
POWER CONSUMPTION:
TRANSIENT PROTECTION:
100-240VAC/DC, 24VAC, 12-24VDC
50/60Hz (AC Models)
2.5VA (AC Models), 2.5W (DC Models)
MOV
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
Electromechanical relay or transistor
10,000,000 operations (Relay only)
Relay - 100,000 operations minimum (at full rated load)
Transistor - 10,000,000 operations min.
Relay - 5A @ 240VAC (resistive)
Transistor - 100mA, 30VDC maximum
RATING:
TYPE:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
OPERATING TEMP:
TIMING VARIATION VS. TEMP:
MOUNTING:
TERMINATION:
HOUSING:
OUTPUT
TIMING
Multifunction
±0.005% of setting
20 msec
0.001 seconds to 9999 hours
PHYSICAL
-10° to 50° C (-14° to 122° F)
±0.005%
Plug-in or Panel Mount
8-pin socket
Polycarbonate
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1096
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
WIRING
Output A
Output C
Control
Reset
4
Control
5
5
Reset
Load
3
6
3
4
+
6
-
External
Switches
2
7
1
*(-)
*Polarity
indicated for DC
models only
8
Input Voltage
(Control)
(+)
External
Switches
2
7
1
*(-)
8
Input Voltage
(Control)
(+)
Do not apply voltage to pins 3 and 4. Control and Reset
accomplished by isolated contact closure.
DIMENSIONS
MOUNTING
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
DIN RAIL MOUNT
8 Pin socket
RP-320 has built
in hold down
clips and is DIN
rail compatible.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1096
PANEL MOUNT
Kanson Electronics, Inc.
TIMER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1096
INPUT VOLTAGE
1
100-240 VAC
2
12-24 VDC
3
24 VAC
TIME RANGE
P
0.001 sec to 9,999 hr
TIMING FUNCTIONS
3
Selectable
Pulse A
One Cycle
Pulse B
Repeat Cycle
Pulse C
Repeat Cycle
Total A
One Cycle
Total B
Repeat Cycle
Total C
Repeat Cycle
OUTPUT
A
Relay SPDT
C
Open collector transistor
APPLICABLE ACCESSORIES
See accesory section for details
8 pin socket
8 pin revervible socket
8 pin cable socket
Panel mount clip
Protective cover
1096 - 1 - P - 3 - A
Start Off
Start On
Start Off
Start On
RP-320
RP-321
RP-323
RP-325
RP-326
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 2110
BLOCK
Kanson Electronics, Inc.
TIMER
I
Compact encapsulated timer with simple two-wire installation.
Features:
• Time ranges selectable from 0.1 to 10230 seconds.
• 24 to 140 V AC/DC or 100 to 240 V AC/DC input.
• 1Amp solid state output.
ON DELAY
TIMING
ON DELAY
• Control is affected with power application.
• When power turns on, delay time elapses before
timed output turns on. The timed output remains on
until the unit is reset by removing power.
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
24-140VAC/DC or 100-240VAC/DC
50/60Hz or DC
±10% of nominal
1VA maximum
Transient protected
TYPE:
RATING:
VOLTAGE DROP:
Solid State N.O.
1A @ 240VAC/DC maximum (10A 1 cycle surge)
2.5V typical @ 1A
TYPE:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
RANGE TOLERANCE:
CONTROL:
OUTPUT
TIMING
On delay
≤0.5% of setting
≤50 msec
0.1 to 10230 seconds in 3 ranges
±5% of setting
Power applied to input initiates timing cycle
PHYSICAL
OPERATING TEMP:
-40° to 80° C (-40° to 176° F)
TIMING VARIATION VS. TEMP: ±5% maximum
MOUNTING:
Surface with #8 or #10 screws
TERMINATION:
0.250 inch male quick connect terminals
HOUSING:
Plastic
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 2110
BLOCK
Kanson Electronics, Inc.
TIMER
I
WIRING
Warning: Connection of
power without a series
load will cause
permanent damage.
DIMENSIONS inch (mm)
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
2110
INPUT VOLTAGE
1
2
TIME RANGE (seconds)
A
B
C
TIMING FUNCTION
1
OUTPUT
C
2110 - 1 - A - 1 - C
24 - 140 V AC/DC
100 - 240 V AC/DC
0.1 - 102.3
1.0 - 1023
10 - 10230
ON Delay
Solid state N.O. 1 amp maximum
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 2115
BLOCK
Kanson Electronics, Inc.
TIMER
I
Compact encapsulated timer with a simple three-wire installation.
Features:
• Time ranges from 0.1 to 10230 seconds.
• 120 VAC or 240 VAC
• 1Amp solid state output.
U
UL File No. E50957
C CSA File No. LR92518
TIMING
INTERVAL
INTERVAL
• Control is affected with power application.
• When power is applied, output turns on and remains
on till delay time is elapsed.
SPECIFICATIONS
INPUT
VOLTAGE:
FREQUENCY:
TOLERANCE (VOLTAGE):
POWER CONSUMPTION:
TRANSIENT PROTECTION:
120VAC or 240VAC
50/60Hz
±15% of nominal
1VA maximum
Transient protected
TYPE:
RATING:
VOLTAGE DROP:
Solid State N.O.
1A @ 240VAC/DC maximum (10A 1 cycle surge)
2.5V typical @ 1A
MAINTAINED TYPE:
REPEAT ACCURACY:
RESET TIME:
TIME RANGE:
RANGE TOLERANCE:
CONTROL:
Interval
≤0.5% of setting
≤50 msec
0.1 to 10230 seconds in 3 ranges
±5% of setting
Power applied to input initiates timing cycle
OUTPUT
TIMING
PHYSICAL
OPERATING TEMP:
-40° to 60° C (-40° to 140° F)
TIMING VARIATION VS. TEMP: ±5% maximum
MOUNTING:
Surface with #8 or #10 screws
TERMINATION:
0.250 inch male quick connect terminals
HOUSING:
Plastic
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 2115
BLOCK
Kanson Electronics, Inc.
TIMER
I
WIRING
DIMENSIONS inch (mm)
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
2110
INPUT VOLTAGE
1
2
TIME RANGE (seconds)
A
B
C
TIMING FUNCTION
5
OUTPUT
C
2115 - 1 - B - 5 - C
120 VAC
240 VAC
0.1 - 102.3
1.0 - 1023
10 - 10230
Interval
Solid state N.O. 1 amp maximum
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
®
INDUSTRIAL SOLID STATE MODEL 1105C
PANEL MOUNT
Kanson Electronics, Inc.
COUNTER
I
Multifunction digital counter with dual input control.
Features:
•7 output control functions.
•5 input modes.
•Both input and reset contacts independent of unit power.
•100-240 VAC or 12-24 VDC input.
•5 amp relay or open collector transistor output.
•Battery backed up memory.
U
C
OUTPUT FUNCTIONS
HOLD A - Latched Output / Hold Count
• Control is independent of unit power.
• Upon counting to set value, output latches on and
count input is inhibited.
• Output remains on until reset.
HOLD B - Latched Output / Over Count
• Control is independent of unit power.
• Upon counting to set value, output latches on and
count continues to increment.
• Output remains on until reset.
HOLD C - Latched Output(one count) / Over Count
• Control is independent of unit power.
• Upon counting to set value, output latches on.
• Output turns off at next count following set value.
• Count continues to increment.
®
INDUSTRIAL SOLID STATE MODEL 1105C
PANEL MOUNT
Kanson Electronics, Inc.
COUNTER
I
OUTPUT FUNCTIONS (cont)
SHOT A - One shot / Continue Count
• Control is independent of unit power.
• Upon counting to set value, output turns on for
approximately 1 second.
• Count continues to increment.
SHOT B - One Shot / Reset "ON"
• Control is independent of unit power.
• Upon conting to set value, output turns on for
approximately 1 second and the count is
automatically reset.
• Count may be continued from this point with no
requirement for external reset.
SHOTC - One Shot / Reset "OFF"
• Control is independent of unit power.
• Upon counting to set value, output turns on for
approximately 1 second.
• Count automatically resets at the same time the
output turns off.
SHOT D - One Shot / Hold Count
• Control is independent of unit power.
• Upon counting to set value, output turns on for
approximately 1 second.
• Count is inhibited while output is on.
• Count automatically resets at the same time the
output turns off.
®
INDUSTRIAL SOLID STATE MODEL 1105C
PANEL MOUNT
Kanson Electronics, Inc.
COUNTER
I
INPUT MODE
UP - Count up to set value.
•Input 1 is count input.
•Input 2 inhibits count input.
DOWN - Count down from set value
•Input 1 is count input.
•Input 2 inhibits count input.
DIR - Directional count - UP or DOWN
•Input 1 is count input.
•Input 2 off - count will go up.
•Input 2 on - count will go down.
IND - Independant inputs
•Input 1 counts up.
•Input 2 counts down.
PHASE - Phasing of inputs
determines count direction
•If input 1 is phased ahead of input 2 - count is up.
•If input 2 is phased ahead of input 1 - count is down.
SPECIFICATIONS
VOLTAGE:
FREQUENCY:
POWER CONSUMPTION:
TRANSIENT PROTECTION:
TYPE:
MECHANICAL LIFE:
ELECTRICAL LIFE:
RATING:
INPUT
100-240VAC/DC, 12-24VAC
50/60Hz (AC Models)
2.5VA (AC Models)
2.5W (DC Models)
MOV
OUTPUT
Electromechanical relay or transistor
10,000,000 operations (Relay only)
Relay - 100,000 operations minimum (at full rated load)
Transistor - 10,000,000 operations min.
Relay - 5A @ 240VAC (resistive)
Transistor - 100mA, 30VDC maximum
COUNTER OUTPUT
MODES:
DISPLAY:
7 (Programmable)
6 digit LCD
TYPE:
SPEED:
NUMBER OF INPUTS:
INPUT METHOD:
Multifunction
30/sec. or 5000/sec.
Two
Isolated contact or transistor
OPERATING TEMP:
MOUNTING:
TERMINATION:
HOUSING:
-10° to 50° C (-14° to 122° F)
Plug-in or Panel Mount
Relay Output - 11-pin socket, Transistor Output - 8-pin socket
Polycarbonate
CONTROL INPUT
PHYSICAL
®
INDUSTRIAL SOLID STATE MODEL 1105C
PANEL MOUNT
Kanson Electronics, Inc.
COUNTER
I
WIRING
Output A
Output C
*Polarity indicated
for DC models only
Do not apply voltage to pins 5,6,7. Reset and Count inputs
accomplished by isolated contact closure.
DIMENSIONS inch (mm)
MOUNTING mm
PANEL MOUNT
Panel mount clip
RP-325 allows
access to the
timer face though
the panel.
DIN RAIL MOUNT
8 Pin socket
RP-320 has built
in hold down
clips and is DIN
rail compatible.
®
INDUSTRIAL SOLID STATE MODEL 1105C
PANEL MOUNT
Kanson Electronics, Inc.
COUNTER
I
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1105C
INPUT VOLTAGE
1
2
INPUT MODE
P
UP
DOWN
DIR
IND
PHASE Phased
TIMING FUNCTIONS
3
1105C - 1 - P - 3 - A
100-240 VAC
12-24 VDC
Counts up
Counts down
Directional count
Independant inputs
inputs
Selectable
HOLD A
HOLD B
HOLD C
SHOT A
SHOT B
SHOT C
SHOT D
Latched Output / Hold Count
Latched Output / Over Count
Latched Output (one count) / One Count
One Shot / Continue Count
One Shot / Reset "ON"
One Shot / Reset "OFF"
One Shot / Hold Count
OUTPUT
A
C
Relay SPDT
Open collector transistor
APPLICABLE ACCESSORIES
See accesory section for details
11 pin socket
11 pin cable socket
Panel mount clip
Protective cover
RP-322
RP-324
RP-325
RP-326
®
I INDUSTRIAL SOLID STATE MODEL 1120H
HOURMETER
Kanson Electronics, Inc.
The Model 1120H Features:
• Ideal for scheduling routine maintanance.
• DC powerd.
• Suitable for harsh environments IP66 compliant.
• High performance compact sync. motor.
• Ultra-accurate quartz oscillator.
U C E
VOLTAGE:
POWER CONSUMPTION:
SPECIFICATIONS
INPUT
12 or 24 VDC
1.5 W at 25°C
TIMING
RANGE:
MINIMUM DISPLAY:
0.0 to 9999.9 Hours
6 Minutes
VIBRATION RESISTANCE:
10 to 55 Hz: 1 cycle/min double amplitude
of 0.5 mm (10 min on 3 axes)
Functional: Min. 98m/s2 (4 times on 3 axes)
Destructive: 980m/s2 (4 times on 3 axes)
-20° to 60° C (-4° to 140° F)
45% to 85% relative humidity
Screw terminals
Plastic - IP66 compliant at panel face
SHOCK RESISTANCE:
OPERATING TEMP:
OPERATING HUMIDITY:
TERMINATION:
HOUSING:
PHYSICAL
DIMENSIONS mm
ORDERING DATA
ORDERING CODE
BASIC MODEL NUMBER
1120H
INPUT VOLTAGE
1
2
1120H - 2
12 VDC
24 VDC
PANEL MOUNT
I
®
Kanson Electronics, Inc.
DIGITAL CONTROLLER
PROGRAMMING INSTRUCTIONS
1094 PROGRAMMING
DIP Switches:
• 1, 2 and 3 Select from 8 output function options.
•4
Set minimum input signal length
(reset, signal, stop and lock).
•5
Sets direction of time delay
(addition or subtraction).
• 6, 7 and 8 Select T1 time range.
(0.001 s to 9.999 s thru 0.1 h to 999.9h)
Set dip switches before installation!
1105C PROGRAMMING
DIP Switches:
• 1, 2 and 3 Select from 7 output function options.
•4
Set minimum input signal length
(reset, input 1, input 2 and lock).
•5
Sets maximum count speed
(30 Hz or 5kHz).
• 6, 7 and 8 Select from 5 input options.
Set dip switches before installation!
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
I
®
Kanson Electronics, Inc.
DIGITAL CONTROLLER
PROGRAMMING INSTRUCTIONS
1096 PROGRAMMING
Checking Timing Function:
Hold down (SET/LOCK).
Toggle 2nd key up or down.
Release (SET/LOCK).
Display returns to normal after
two seconds.
Changing Timing Function:
Timing function representations:
Pulse
One
Cycle
Hold down (SET/LOCK).
Toggle 1st key up or down.
Release (SET/LOCK).
Toggle 1st key to select desired timing function.
Press (RESET) key to accept timing function.
Procedure is independant of T1 or T2.
Pulse
Repeat
OFF-start
Pulse
Repeat
ON-start
Total
One
Cycle
Total
Repeat
OFF-start
Total
Repeat
ON-start
Setting T1 and T2:
Press (SET/LOCK) key to switch between T1 and T2.
Time is set using the toggle keys on the front of the timer.
Each key is for the corresponding digit on the display.
Setting The Lock:
Hold down (SET/LOCK).
Toggle 4th key up or down.
Release (SET/LOCK).
Lock is set.
Repeat procedure to unlock.
DIP Switches:
• 1, 2 and 3 Select T1 time range.
(0.001 s to 9.999 s thru 0.1 h to 999.9h)
•4
Set minimum input signal length
(reset, signal, and lock).
•5
Sets direction of time delay
(addition or subtraction).
• 6, 7 and 8 Select T2 time range.
(0.001 s to 9.999 s thru 0.1 h to 999.9h)
Set dip switches before installation!
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF