ClimateMaster Tranquility 22 Digital TZ geothermal heat pump Installation, Operation & Maintenance Instructions
Below you will find brief information for geothermal heat pump Tranquility 22 Digital TZ. Tranquility 22 Digital TZ is a residential horizontal & vertical packaged geothermal heat pump for comfortable heating and cooling of residential spaces. This unit comes with internal flow control and an internal variable speed pump. It also includes an expansion tank, flushing ports and three-way valves. The variable speed pump is controlled by a communicating DXM2 board based on the difference between the entering and leaving water temperatures (ΔT).
PDF
Document
Advertisement
Advertisement
Tranquility® 22 Digital (TZ) Series IOM Tranquility® 22 Digital (TZ) 97B0072N11 Residential Horizontal & Vertical Packaged Geothermal Heat Pumps Installation, Operation & Maintenance Instructions Rev.: 17 Jan., 2013B Table of Contents Model Nomenclature Storage Pre-Installation Vertical Installation Horizontal Installation Condensate and Water Connection vFlow™ Heat Pump Applications Overview Closed Loop Heat Pump Applications with Internal Flow Controller Flushing the Earth Loop Multiple Unit Piping & Flushing Ground Loop Heat Pump Applications Closed Loop - External Central Pumping Applications Open Loop or Ground-Water Heat Pump Applications Water Quality Standards Hot Water Generator Electrical - Line Voltage Electrical - Low Voltage Wiring 3 4 4 5 6-8 9 10 11 12-14 15-17 18-19 20 21-22 22 23-25 26 27 Electrical - Thermostat Wiring Wiring Diagrams ECM Blower Control Blower Data DXM2 Controls DXM2 Layout and Connections Unit Commissioning And Operating Conditions Unit Start-Up and Operating Conditions Unit Start-Up Procedure Coax Pressure Drop Table Unit Operating Conditions Performance Data Preventive Maintenance Troubleshooting DXM2 Process Flow Chart Functional & Performance Troubleshooting Troubleshooting Form Warranty Revision History 28 29-32 33 34 35 36 37 38 38-40 41 42-43 44-49 50 51-52 53 54-57 58 59 60 This page was intentionally left blank. Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Model Nomenclature: General Overview 1 2 3 4 5 6 7 TZ V 024 B G D 0 8 9 10 11 12 13 14 15 2 C L T S STANDARD SERIES S = Standard TZ = Tranquility® 22 Digital SUPPLY AIR FLOW & MOTOR CONFIGURATION CONFIGURATION V = Vertical Up H = Horizontal T B S UNIT SIZE Supply Configuration Top TZV TZH Back TZH Straight Motor ECM ECM ECM 024, 030, 036, 042, 048, 060 RETURN AIR FLOW CONFIGURATION L = Left Return w/ 1” Merv 8 pleated filter and frame R = Right Return w/ 1” Merv 8 pleated filter and frame REVISION LEVEL A = Current Revision for 030, 042, 048 B = Current Revision for 024, 036, 060 HEAT EXCHANGER OPTIONS VOLTAGE G = 208-230/60/1 HWG W/Pump (Standard) No HWG Tin Plated Air Coil Copper Cupro-Nickel C N A J CONTROLS D = DXM2 WATER CIRCUIT OPTIONS 2 = Magna Internal Flow Controller - Closed Loop 5 = Motorized Modulating Valve (Central Pumping Applications) - Closed Loop 6 = Motorized Valve (Modulating) Open Loop Applications, High System Pressure Drop CABINET 0 = Residential In Position 11 and 12, only the following combinations are available: With HWG Without HWG Description 2C 2A Internal Flow Controller with Copper Water Coil 5C 5A Motorized Modulating Valve with Copper Water Coil 6N 6J Motorized Modulating Valve with Cupro-Nickel Water Coil NOTE: Above model nomenclature is a general reference. Consult individual specification sections for detailed information. Safety Warnings, cautions and notices appear throughout this manual. Read these items carefully before attempting any installation, service, or troubleshooting of the equipment. CAUTION: Indicates a potentially hazardous situation or an unsafe practice, which if not avoided could result in minor or moderate injury or product or property damage. DANGER: Indicates an immediate hazardous situation, which if not avoided will result in death or serious injury. DANGER labels on unit access panels must be observed. NOTICE: Notification of installation, operation or maintenance information, which is important, but which is not hazardrelated. WARNING: Indicates a potentially hazardous situation, which if not avoided could result in death or serious injury. WARNING! WARNING! WARNING! The EarthPure® Application and Service Manual should be read and understood before attempting to service refrigerant circuits with HFC-410A. WARNING! All refrigerant discharged from this unit must be recovered WITHOUT EXCEPTION. Technicians must follow industry accepted guidelines and all local, state, and federal statutes for the recovery and disposal of refrigerants. If a compressor is removed from this unit, refrigerant circuit oil will remain in the compressor. To avoid leakage of compressor oil, refrigerant lines of the compressor must be sealed after it is removed. WARNING! CAUTION! WARNING! To avoid the release of refrigerant into the atmosphere, the refrigerant circuit of this unit must be serviced only by technicians who meet local, state, and federal proficiency requirements. CAUTION! To avoid equipment damage, DO NOT use these units as a source of heating or cooling during the construction process. The mechanical components and filters will quickly become clogged with construction dirt and debris, which may cause system damage. c l i m a t e m a s t e r. c o m 3 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B General Information Inspection Upon receipt of the equipment, carefully check the shipment against the bill of lading. Make sure all units and accessories have been received. Inspect the packaging of each unit, and inspect each unit for damage. Insure that the carrier makes proper notation of any shortages or damage on all copies of the freight bill and completes a common carrier inspection report. Concealed damage not discovered during unloading must be reported to the carrier within 15 days of receipt of shipment. If not filed within 15 days, the freight company can deny the claim without recourse. Note: It is the responsibility of the purchaser to file all necessary claims with the carrier. Notify your equipment supplier of all damage within fifteen (15) days of shipment. Storage Equipment should be stored in its original packaging in a clean, dry area. Store units in an upright position at all times. Stack units a maximum of 3 units high. Unit Protection Cover units on the job site with either the original packaging or an equivalent protective covering. Cap the open ends of pipes stored on the job site. In areas where painting, plastering, and/or spraying has not been completed, all due precautions must be taken to avoid physical damage to the units and contamination by foreign material. Physical damage and contamination may prevent proper start-up and may result in costly equipment clean-up. Examine all pipes, fittings, and valves before installing any of the system components. Remove any dirt or debris found in or on these components. Pre-Installation Installation, Operation, and Maintenance instructions are provided with each unit. Horizontal equipment is designed for installation above false ceiling or in a ceiling plenum. Other unit configurations are typically installed in a mechanical room. The installation site chosen should include adequate service clearance around the unit. Before unit start-up, read all manuals and become familiar with the unit and its operation. Thoroughly check the system before operation. Prepare units for installation as follows: 1. Compare the electrical data on the unit nameplate with ordering and shipping information to verify that the correct unit has been shipped. 2. Keep the cabinet covered with the original packaging until installation is complete and all plastering, painting, etc. is finished. 3. Verify refrigerant tubing is free of kinks or dents and that it does not touch other unit components. 4. Inspect all electrical connections. Connections must be clean and tight at the terminals. 5. Remove any blower support packaging (water-to-air units only). 6. Locate and verify any hot water generator (HWG), hanger, or other accessory kit located in the compressor section or blower section. 4 CAUTION! CAUTION! DO NOT store or install units in corrosive environments or in locations subject to temperature or humidity extremes (e.g., rooftops, etc. See Tables 9a and 9b for acceptable temperature ranges). Corrosive conditions and high temperature or humidity can significantly reduce performance, reliability, and service life. Always move and store units in an upright position. Tilting units on their sides may cause equipment damage. CAUTION! CAUTION! CUT HAZARD - Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing heat pumps. Duct System Installation The duct system should be sized to handle the design airflow quietly. Refer to Figure 6a and 6b for horizontal duct system details or Figure 2 for vertical duct system details. A flexible connector is recommended for both discharge and return air duct connections on metal duct systems to eliminate the transfer of vibration to the duct system. To maximize sound attenuation of the unit blower, the supply and return plenums should include internal fiberglass duct liner or be constructed from ductboard for the first few feet. Application of the unit to uninsulated ductwork in an unconditioned space is not recommended, as the unit’s performance will be adversely affected. At least one 90° elbow should be included in the supply duct to reduce air noise. If air noise or excessive air flow is a problem, the blower speed can be changed. For airflow charts, consult catalog specifications for the series and model of the specific unit. If the unit is connected to existing ductwork, a previous check should have been made to insure that the ductwork has the capacity to handle the airflow required for the unit. If ducting is too small, as in the replacement of a heating only system, larger ductwork should be installed. All existing ductwork should be checked for leaks and repaired as necessary. The installation of geothermal heat pump units and all associated components, parts and accessories which make up the GHP system shall be in accordance with the regulations of ALL authorities having jurisdiction and MUST conform to all applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations. Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Vertical Installation Vertical Unit Location Packaged units are not designed for outdoor installation. Locate the unit in an INDOOR area that allows enough space for service personnel to perform typical maintenance or repairs without removing the unit from the installed location. Vertical units are typically installed in a mechanical closet or basement. Never install units in areas subject to freezing or where humidity levels could cause cabinet condensation (such as unconditioned spaces subject to 100% outside air). Also, provide sufficient room to make water, electrical, and duct connection(s). If the unit is located in a confined space, such as a closet, provisions must be made for return air to freely enter the space by means of a louvered door or other method. Any access panel screws that would be difficult to remove after the unit is installed should be removed prior to setting the unit. Refer to Figures 1 and 2 for typical installation illustrations. Refer to unit catalog specifications for dimensional data. 1. Install the unit on a piece of rubber, neoprene or other mounting pad material for sound isolation. The pad should be at least 3/8” [10mm] to 1/2” [13mm] in thickness. Extend the pad beyond all four edges of the unit. 2. Do not block filter access with piping, conduit or other materials. Refer to unit catalog specifications for dimensional data. 3. Provide access to water valves and fittings and screwdriver access to the unit side panels, discharge collar and all electrical connections. Figure 1: Vertical Unit Mounting Figure 2: Typical Vertical Unit Installation Using Ducted Return Air Internally insulate supply duct for first 3.9 feet (1.2 m) each way to reduce noise Use turning vanes in supply transition Flexible canvas duct connector to reduce noise and vibration Rounded return transition Internally insulate return transition duct to reduce noise Sound Attenuation for Vertical Units Sound attenuation is achieved by enclosing the unit within a small mechanical room or a closet. Additional measures for sound control include the following: 1. If free return, mount the unit so that the return air inlet is 90° to the return air grille (refer to Figure 3). Install a sound baffle as illustrated to reduce line-of sight sound transmitted through return air grilles. 2. Mount the unit on a Tranquility® Unit Isolation Pad to minimize vibration transmission to the building structure. For more information on Tranquility® Unit Isolation Pads, contact your distributor. Figure 3: Vertical Sound Attenuation Return Air Inlet $LU3DGRUH[WUXGHG SRO\VW\UHQHLQVXODWLRQERDUG c l i m a t e m a s t e r. c o m 5 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Horizontal Installation Horizontal Unit Location Packaged units are not designed for outdoor installation. Locate the unit in an INDOOR area that allows enough space for service personnel to perform typical maintenance or repairs without removing unit from the ceiling. Horizontal units are typically installed above a false ceiling or in a ceiling plenum. Never install units in areas subject to freezing or where humidity levels could cause cabinet condensation (such as unconditioned spaces subject to 100% outside air). Consideration should be given to access for easy removal of the filter and access panels. Provide sufficient room to make water, electrical, and duct connection(s). If the unit is located in a confined space, such as a closet, provisions must be made for return air to freely enter the space by means of a louvered door or any other method. Any access panel screws that would be difficult to remove after the unit is installed should be removed prior to setting the unit. Refer to Figures 7a and 7b for an illustration of a typical installation. Refer to unit catalog specifications for dimensional data. Conform to the following guidelines when selecting a unit location: 1. Provide a hinged access door in concealed-spline or plaster ceilings. Provide removable ceiling tiles in T-bar or lay-in ceilings. Refer to horizontal unit dimensions for specific series and model in unit catalog specifications. Size the access opening to accommodate the service technician during the removal or replacement of the compressor and the removal or installation of the unit itself. 2. Provide access to hanger brackets, water valves and fittings. Provide screwdriver clearance to access panels, discharge collars and all electrical connections. 3. DO NOT obstruct the space beneath the unit with piping, electrical cables and other items that prohibit future removal of components or the unit itself. 4. Use a manual portable jack/lift to lift and support the weight of the unit during installation and servicing. The installation of geothermal heat pump units and all associated components, parts and accessories which make up the GHP system shall be in accordance with the regulations of ALL authorities having jurisdiction and MUST conform to all applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations. Mounting Horizontal Units Horizontal units have hanger kits pre-installed from the factory as shown in Figure 5. Figures 7a and 7b shows a typical horizontal unit installation. Horizontal heat pumps are typically suspended above a ceiling or within a soffit using field supplied, threaded rods sized to support the weight of the unit. Use four (4) field supplied threaded rods and factory provided vibration isolators to suspend the unit. Hang the unit clear of the floor slab above and support the unit by the mounting bracket assemblies only. DO NOT attach the unit flush with the floor slab above. Pitch the unit toward the drain as shown in Figure 6 to improve the condensate drainage. On small units (less than 2.5 Tons/8.8 kW) ensure that unit pitch does not cause condensate leaks inside the cabinet. NOTE: The top panel of a horizontal unit is a structural component. The top panel of a horizontal unit must never be removed from an installed unit unless the unit is properly supported from the bottom. Otherwise, damage to the unit cabinet may occur. Figure 4: Hanger Bracket >PP@7KUHDGHG 5RGE\RWKHUV 9LEUDWLRQ,VRODWRU IDFWRU\VXSSOLHG :DVKHU E\RWKHUV 'RXEOH+H[1XWV E\RWKHUV Figure 5: Horizontal Unit Pitch 1/4” (6.4mm) pitch per foot for drainage Drain Connection 6 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Horizontal Installation Figure 6a: Typical Closed Loop Horizontal Unit Installation (with Internal Flow Controller) Water Pressure Ports 3/8" [10mm] threaded rods (by others) Flexible Duct Connector Return Duct Water Out Water In Power Wiring Use turning vanes or a double radius elbow Supply Air Unit Power Vibration Isolation Pad Insulated supply duct with at least one 90 deg turn to reduce air noise Flexible Duct Connector Unit Power Disconnect (by others) Secondary Drain Pan Platform Unit Hanger Thermostat Wiring Internal Variable-Speed Pump Flush Ports Figure 6b: Typical Ground Water Horizontal Unit Installation (with Internal Motorized Modulating Valve) Water Pressure Ports :DWHU 2XW Air Coil - To obtain maximum performance, the air coil should be cleaned before start-up. A 10% solution of dishwasher detergent and water is recommended for both sides of the coil. A thorough water rinse should follow. Pressure Tank :DWHU,Q Internal Motorized Modulating Valve c l i m a t e m a s t e r. c o m Boiler Drains Ball Valves 7 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Horizontal Installation Field Conversion of Air Discharge Figure 7: Left Return Side to Back Overview - Horizontal units can be field converted between side (straight) and back (end) discharge using the instructions below. Remove Screws Water Connection End Return Air Note: It is not possible to field convert return air between left or right return models due to the necessity of refrigeration copper piping changes. Preparation - It is best to field convert the unit on the ground before hanging. If the unit is already hung it should be taken down for the field conversion. Side to Back Discharge Conversion Place unit in well lit area. Remove the screws as shown 1. in Figure 8 to free top panel and discharge panel. 2. Lift out the access panel and set aside. Lift and rotate the discharge panel to the other position as shown, being careful with the blower wiring. 3. Check blower wire routing and connections for tension or contact with sheet metal edges. Reroute if necessary. 4. Check refrigerant tubing for contact with other components. 5. Reinstall top panel and screws noting that the location for some screws will have changed. 6. Manually spin the fan wheel to ensure that the wheel is not rubbing or obstructed. 7. Replace access panels. Side Discharge Water Connection End Rotate Return Air Move to Side Replace Screws Water Connection End Return Air Back to Side Discharge Conversion - If the discharge is changed from back to side, use above instruction noting that illustrations will be reversed. Left vs. Right Return - It is not possible to field convert return air between left or right return models due to the necessity of refrigeration copper piping changes. However, the conversion process of side to back or back to side discharge for either right or left return configuration is the same. In some cases, it may be possible to rotate the entire unit 180 degrees if the return air connection needs to be on the opposite side. Note that rotating the unit will move the piping to the other end of the unit. Drain Discharge Air Back Discharge Figure 8: Right Return Side to Back Water Connection End Return Air Supply Duct Side Discharge Return Air Drain Discharge Air 8 Geothermal Heat Pump Systems Back Discharge Water Connection End Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Condensate and Water Connection Condensate Piping Pitch the unit toward the drain as shown in Figure 6 to improve the condensate drainage. On small units (less than 2.5 tons/8.8 kW), insure that unit pitch does not cause condensate leaks inside the cabinet. Install condensate trap at each unit with the top of the trap positioned below the unit condensate drain connection as shown in Figure 9. Design the depth of the trap (waterseal) based upon the amount of External Static Pressure (ESP) capability of the blower (where 2 inches [51mm] of ESP capability requires 2 inches [51mm] of trap depth). As a general rule, 1-1/2 inch [38mm] trap depth is the minimum. Each unit must be installed with its own individual trap and connection to the condensate line (main) or riser. Provide a means to flush or blow out the condensate line. DO NOT install units with a common trap and/or vent. Water Connections-Residential (Distributor) Models Residential models utilize swivel piping fittings for water connections that are rated for 450 psi (3101 kPa) operating pressure. The connections have a rubber gasket seal similar to a garden hose gasket, which when mated to the flush end of most 1” threaded male pipe fittings provides a leakfree seal without the need for thread sealing tape or joint compound. Check for burrs and ensure that the rubber seal is in the swivel connector prior to attempting any connection (rubber seals are shipped attached to the swivel connector). DO NOT OVER TIGHTEN or leaks may occur. The female locking ring is threaded onto the pipe threads which holds the male pipe end against the rubber gasket, and seals the joint. HAND TIGHTEN ONLY! DO NOT OVERTIGHTEN! Figure 11: Water Connections Always vent the condensate line when dirt or air can collect in the line or a long horizontal drain line is required. Also vent when large units are working against higher external static pressure than other units connected to the same condensate main since this may cause poor drainage for all units on the line. WHEN A VENT IS INSTALLED IN THE DRAIN LINE, IT MUST BE LOCATED AFTER THE TRAP IN THE DIRECTION OF THE CONDENSATE FLOW. Figure 9: Condensate Connection Swivel Nut Stainless steel snap ring Hand Tighten Only! Do Not Overtighten! Gasket Brass Adaptor ರ ರ3HU )RRW ರ ರ * Some units include a painted drain connection. Using a threaded pipe or similar device to clear any excess paint accumulated inside this fitting may ease final drain line installation. CAUTION! CAUTION! Ensure condensate line is pitched toward drain 1/8 inch per ft [11mm per m] of run. c l i m a t e m a s t e r. c o m 9 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B vFlow™ Heat Pump Applications Overview vFlow™ is a revolutionary new, intelligent, and efficient way to circulate water (or water plus antifreeze) using INTERNAL, variable water flow control. The factory-installed highefficiency variable-speed pump uses 60%-80% less wattage than a traditional fixed speed pump. vFlow™ technology improves performance of the unit by reducing the amount of energy required to optimize the flow of water throughout a GHP System and also reduces the space, cost, and labor required to install external water flow control mechanisms (flow controllers, solenoid and flow control valves). vFlow™ Configurations: 1) Internal Flow Controller - For Closed Loop Applications This is the most common configuration for closed loops. With this factory-installed standard option, the unit is built with an Internal Variable Speed Pump and other components to flush and operate the unit correctly (including an expansion tank, flush ports and flushing valves). The pump speed is controlled by the DXM2 control based on the difference in entering and leaving water temperatures (∆T). The Internal Flow Controller pump includes an internal check valve for multiple unit installations. A copper water coil is standard with this option. Note: Internal Flow Controllers are also very suitable for multiple unit installations depending on pump performance requirements. 2) Internal Modulating Motorized Valve – For Large Closed Loop Applications (external central pumping) Primarily for use on multi-unit closed loop applications with central pumping. With this factory-installed option, the unit includes a low pressure drop modulating motorized valve that is controlled by the DXM2 microprocessor control based on the difference in the entering and leaving water temperatures (∆T). A Copper Water Coil is standard with this option. The modulating valve in this option has a higher Cv than the open loop option. 3) Internal Modulating Motorized Valve - For Open Loop Applications For use on open loop applications. With this factoryinstalled, standard option, the unit is built with an internal modulating motorized valve controlled by the Communicating DXM2 control board based on entering and leaving water temperatures (∆T). A low Cv modulating motorized valve is used for this application to provide more precise control against the higher system pressure differential of open loop applications. A CuproNickel water coil comes standard with this option. Details on these options are included in the following sections on ground loop and ground water applications. 10 Figure 11a: Typical Closed-Loop Application (with Internal Flow Controller Shown) To Thermostat Internal Flow Controller Water Out High and Low Voltage Knockouts Water In Vibration Isolation Pad Figure 11b: Typical Open Loop Application (with Internal Modulating Motorized Valve Shown) For use on applications using external source for flow To Thermostat Internal Motorized Modulating Valve Pressure Tank Water Out Water In High and Low Voltage Knockouts Boiler Drains Shut Off Ball Valves for Isolation Optional Filter Vibration Isolation Pad CAUTION! CAUTION! The following instructions represent industry accepted installation practices for closed loop earth coupled heat pump systems. Instructions are provided to assist the contractor in installing trouble free ground loops. These instructions are recommendations only. State/provincial and local codes MUST be followed and installation MUST conform to ALL applicable codes. It is the responsibility of the installing contractor to determine and comply with ALL applicable codes and regulations. Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Closed Loop Heat Pump Applications with Internal Flow Controller Units with internal flow control come with a built-in variable speed pump, an expansion tank, flushing ports and threeway valves (used to flush the unit). The variable speed pump is controlled by the Communicating DXM2 board based on the difference between the entering and leaving water temperature (∆T). For operation outside of the normal entering water temperature range (50° or 60°F - 110°F for cooling, 30°F-70°F for heating) the DXM2 controller may automatically adjust the control ∆T to account for the abnormal entering water temperatures, maintaining an appropriate flow rate for proper unit operation. When entering water temperatures are abnormally low for cooling, or abnormally high for heating, the DXM2 controller will maintain a constant leaving water temperature which will allow the unit to operate properly under those conditions. The internal expansion tank helps to maintain constant loop pressure despite the natural expansion and contraction of the loop as the seasons and loop temperatures vary. The expansion tank also helps to avoid flat loop callbacks. Figure 12: Internal Flow Controller Test individual horizontal loop circuits before backfilling. Test vertical U-bends and pond loop assemblies prior to installation. Pressures of at least 100 psi [689 kPa] should be used when testing. Do not exceed the pipe pressure rating. Test entire system when all loops are assembled. NOTICE! NOTICE! If installing MULTIPLE vFlow™ Internal Variable Speed Flow Controller units (in parallel) on one loop, please refer to section ‘Multiple Unit Piping and Flushing’ (later in this document). Pre-Installation Prior to installation, locate and mark all existing underground utilities, piping, etc. Install loops for new construction before sidewalks, patios, driveways, and other construction has begun. During construction, accurately mark all ground loop piping on the plot plan as an aid in avoiding potential future damage to the installation. The following section will help to guide you through flushing a unit with internal flow control. Water Pressure Schrader Ports The pressure ports built in to the unit are provided as a means of measuring pressure drop through the water-torefrigerant heat exchanger. The water pressure ports are schrader ports smaller than refrigerant schrader ports. They are the same size as tire schrader ports. A digital pressure gauge is recommended for taking pressure readings through these ports. The water flow through the unit can be determined by measuring the water pressure at the “water pressure out” port and subtracting it from the water pressure at the “water pressure in” port. Comparing the pressure differential to the pressure drop table (wpd)/flow rate in Tables 15a through 15d in this manual will determine the flow rate through the unit. Piping Installation The typical closed loop ground source system is shown in Figures 6a and 11a. All earth loop piping materials should be limited to polyethylene fusion only for in-ground sections of the loop and it is also recommended for inside piping. Galvanized or steel fittings should not be used at any time due to their tendency to corrode. All plastic to metal threaded fittings should be avoided due to their potential to leak in ground loop applications. Loop temperatures can range between 25 and 110°F [-4 to 43°C]. Flow rates between 2.25 and 3 gpm per ton [2.41 to 3.23 l/m per kW] of cooling capacity is recommended in these applications. Figure 13: Magna Geo 25-140 Pump Performance GPM Magna Geo 25-140 Pump Curve 60 50 Head (Ft.) 40 30 20 10 0 0 5 10 15 20 25 30 35 40 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 Head (ft) GPM Head (ft) 44.7 45.4 46.1 46.8 47.5 47.7 47.1 46.1 45.3 43.9 42.6 41.2 39.9 38.7 37.4 36.1 34.9 33.7 32.5 19.0 20.0 21.0 22.0 23.0 24.0 25.0 26 27 28 29 30 31 32 33 34 35 36 37 38 Digital Pressure Gauge 31.3 30.1 28.9 27.8 26.7 25.6 24.5 23.4 22.3 21.3 20.2 19.2 18.2 17.3 16.3 15.4 14.4 13.5 12.6 11.7 Flow (GPM) c l i m a t e m a s t e r. c o m 11 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Flushing the Earth Loop Once piping is completed between the unit and the ground loop, final purging and charging of the loop is needed. A flush cart (at least a 1.5 hp [1.1kW] pump) is needed to achieve adequate flow velocity in the loop to purge air and dirt particles from the loop itself. Antifreeze solution is used in most areas to prevent freezing. All air and debris must be removed from the earth loop piping system before operation, Flush the loop with a high volume of water at a high velocity (2 fps [0.6 m/s] in all piping), using a filter in the loop return line, of the flush cart to eliminate debris from the loop system. See Table 17 for flow rate required to attain 2fps [0.6 m/s]. The steps below must be followed for proper flushing. WARNING! WARNING! Disconnect electrical power source to prevent injury or death from electrical shock. Figure 14b: Cam Fittings for Flush Cart Hoses Attach to Flow Controller Flush Port Connect to Flush Cart Hose (1 of 2) Table 1: Minimum Flow Required to Achieve 2 ft/sec variety PE Pipe Size Flow (GPM) 3/4" 4 1" 6 1 1/4" 10 1 1/2" 13 2" 21 Units with internal variable speed pumps also include a check valve internal to the pump. It is not possible to flush backwards through this pump. Care must be taken to connect the flush cart hoses so that the flush cart discharge is connected to the “water in” flushing valve of the heat pump. NOTICE: A hydrostatic pressure test is required on ALL piping, especially underground piping before final backfill per IGSHPA and the pipe manufacturers recommendations. Figure 15a: Valve Position A - Loop Fill/Flush Loop Fill Fill loop (valve position A, see Figure 15a) with water from a garden hose through flush cart before using flush cart pump to ensure an even fill and increase flushing speed. When water consistently returns back to the flush reservoir, switch to valve position B (figure 15b). Isolate expansion tank for flushing procedure using the ball valve. During dead heading of flush cart pump, isolation will prevent compression of bladder in the expansion tank and flush cart fluid level dropping below available capacity. Loop Figure 14a: Typical Cleanable Flush Cart Strainer (100 mesh [0.149mm]) Valve Position Flush Port Out In Front of Unit Valve Position 12 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Flushing the Earth Loop NOTICE: Actual flushing time require will vary for each installation due to piping length, configuration, and flush cart pump capacity. 3/8” or less fluid level drop is the ONLY indication that flushing is complete. Figure 15b: Valve Position B - Unit Fill / Flush Switch valves to Position B to flush the unit. Flush through the unit until all air pockets have been removed. Loop Move valves to position C. By switching both valves to this position, water will flow through the loop and the unit heat exchanger. Finally, the dead head test should be checked again for an indication of air in the loop. Fluid level drop is your only indication of air in the loop. Figure 15d: Valve Position C - Full Flush Valve Position Flush Port Out Add Antifreeze Now if Needed Dead Head Pump Test for Air In Loop Front of Unit Valve Position Loop Flush Switch to valve Position A. The supply water may be shut off and the flush cart turned on to begin flushing. Once the flush reservoir is full, do not allow the water level in the flush cart tank to drop below the pump inlet line or air can be pumped back out to the earth loop. Try to maintain a fluid level in the tank above the return tee so that air can not be continuously mixed back into the fluid. Surges of 50 psi [345 kPa] can be used to help purge air pockets by simply shutting off the flush cart return valve going into the flush cart reservoir. This process ‘dead heads’ the pump to 50 psi [345 kPa]. To dead head the pump until maximum pumping pressure is reached, open the valve back up and a pressure surge will be sent through the loop to help purge air pockets from the piping system. Notice the drop in fluid level in the flush cart tank. If all air is purged from the system, the level will drop only 3/8” in a 10” [25.4 cm] diameter PVC flush tank (about a half gallon [1.9 liters]) since liquids are incompressible. If the level drops more than this level, flushing should continue since air is still being compressed in the loop fluid. Do this a number of times. Valve Position Out Flush Port Unit Fill Unit fill valves should be switched to Position B while flush cart is pumping to fill the unit heat exchanger (see Figure 15b). The valves position should be maintained until water is consistently returned into the flush reservoir. In Front of Unit Valve Position Pressurize and Operate As shown in Figure 15e, close the flush cart return valve to pressurize the loop to at least 50 psi [345 kPa], not to exceed 75 psi [517 kPa]. Open the isolation valve to the expansion tank and bleed air from the expansion tank piping using the schraeder valve located in front of the expansion tank. This will allow loop pressure to compress the expansion tank bladder, thus charging the expansion tank with liquid. After pressurizing, close the flush cart supply valve to isolate the flush cart. Move the Flow Controller valves to Position D. Loop static pressure will fluctuate with the seasons and pressures will be higher in the winter months than during the cooling season. This fluctuation is normal and should be considered when charging the system initially. Unhook c l i m a t e m a s t e r. c o m 13 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Flushing the Earth Loop the flush cart from the Internal Flow Controller. Install Flow Controller caps to ensure that any condensation/leakage remains contained within the Flow Controller package. If the loop pressure is between 50 and 75 psi [345 to 517 kPa] upon completion of flushing, pressures should be sufficient for all seasons. NOTICE: It is recommended to run the unit in the cooling, then heating mode for 15-20 minutes each to ‘temper’ the fluid temperature and prepare it for pressurization. This procedure helps prevent the periodic “flat” loop condition of no pressure. Figure 15e: Valve Position D - Pressurize and Operation 2 Close to isolate Internal Flow Controller 3 Close Internal Flow Controller Valves for Operation Mode 1 Dead Head Pump to Pressurize to 50 PSI Loop Valve Position Flush Port Out In Front of Unit Valve Position 14 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Multiple Unit Piping and Flushing Often projects require more than one heat pump. Where possible, it makes sense for multiple units to share a common ground loop. Common ground loops for multiple units bring new challenges including the need to avoid backward flow through inactive units, increased pumping requirements, and more complex flushing needs. Three types of multiple unit systems are described below along with guidelines for installation of each type. vFlow™ internal variable flow technology is a great assist for systems with multiple units. vFlow™ is available in three different configurations: 1. Internal variable-speed pump 2. Internal modulating valve for closed loops 3. Internal modulating valve for open loops The internal modulating valve for open loops version should never be used on closed loops. The internal variable speed pump version of vFlow™includes an internal Magna variable speed circulator controlled by the DXM2 microprocessor, internal 3-way flushing valves, an internal bladder type expansion tank, and front-mounted pressure ports that allow access to the pressure drop across the coaxial heat exchanger only. The Magna pump includes an internal check valve. The pump curve for the Magna circulator is shown in Figure 13. The internal expansion tank will operate as a pressure battery for the geothermal system. It will absorb fluid from the loop when loop pressure rises and inject fluid into the loop when loop pressure falls. In this way the expansion tank will help to maintain a more constant loop pressure and avoid flat loops due to seasonal pressure changes in the loop. When using the internal variable speed pump as the loop pump in multiple unit installations it is important to ensure that the variable speed pump can provide adequate flow through the heat pump against the loop head when all units are operating. It may be possible to flush a multiple unit system through the unit’s flushing valves. Flushing pressure drop of the valve may be calculated to determine if it is acceptable. Engineering data for the 3-way flushing valves can be found in Table 2. Table 2: Internal 3-Way Flushing Valve Data Model Flushing Connection Straight Flow Cv 90° Flow Cv TZ024 - 42 3/4" FPT 25 10.3 TZ048 - 60 1" FPT 58 14.5 For example, if a system includes two 2-ton units and four ¾ loop circuits we can calculate the flushing pressure drop as follows. From Table 1 we know that it will take 4 gpm to flush each ¾” circuit. If there is no provision to isolate the circuits for flushing, we will have to flush with a minimum of 4 circuits x 4 gpm/circuit = 16 gpm total. A check of other piping sizes used must be done to ensure that 16 gpm total flow will flush all piping. Pressure drop through the flushing valve can be calculated using the following formula. ∆P = (GPM/Cv)2 where, ∆P = pressure drop in psi through the valve while flushing GPM = flushing flow in gallons per minute Cv = valve Cv in flushing mode We know from Table 2 that the Cv for the flushing valve in a TE026 is 10.3 in the flushing mode (90° flow). Therefore, ∆P = (GPM/Cv)2 = (16/10.3)2 = 2.4 psi per valve (there are two flushing valves). So long as the flushing pump is able to provide 16 gpm at the flushing pressure drop of the loop plus the 2.4 x 2 valves = 4.8 psi of the flushing valves, the internal flushing valves may be used. If the flushing pump is not able to overcome the pressure drop of the internal flushing valves, then larger external flushing valves must be used. Unit Configuration Multiple vFlow™ units with internal variable-speed flow controller and check valve, piped in parallel sharing a common loop MUST be configured for ‘VS PUMP PARALLEL’ in Installer Settings Menu. UNIT CONFIGURATION CURRENT CONFIG TZ024 TE026 HEAT PUMP FAMILY TE TZ HEAT PUMP SIZE 026 024 BLOWER TYPE ECM LOOP CONFIG VS PUMP PARALLEL SELECT OPTION PREVIOUS Installer Settings Loop Config SAVE System Config Unit Config Multiple Units with Internal Flow Controllers The simplest multiple unit system is one with two (or more) units utilizing internal Flow Controllers with no external pumps or flushing valves. In this case the units are piped in parallel and use the internal flushing valves to flush the system. The variable speed pump includes an internal check valve to prevent back (short circuiting) flow through the units. In this case, flush the loop through the internal flushing valves in the unit farthest from the loop first. Once the loop is flushed, then change the internal flushing valves to flush the heat pump. Next, move the flushing cart to the next closest unit to the loop. c l i m a t e m a s t e r. c o m 15 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Multiple Unit Piping and Flushing Again, flush the loop through the internal flushing valves. This is important as there may be air/debris in the lines from this unit to the common piping. Once flushing begins the air will be move into the loop and will need to be flushed out. After the loop is flushed through the second unit, change the flushing valves to flush the second unit. This process should be repeated for additional units working from the farthest from the loop to the closest to the loop. This type of application can generally be employed for systems to 12 tons depending on loop design. However, it is important perform appropriate calculations to confirm that the variable speed pump can provide adequate flow through all heat pumps against the loop head when all units are operating. Figure 16a: Multiple Units with Internal Flow Controllers Size for Heat Pump ‘A’ Flow Size for ‘A’ + ‘B’ Flow To Ground Loop Heat Pump A Heat Pump B Size for Heat Pump ‘B’ Flow Water Out Water Out Water In Water In Multiple Units with Internal Flow Controllers and External Flushing Valves When the number of units or flushing requirements reaches a point where it is no longer feasible to flush through the internal valves (generally systems of more than 12 tons depending on loop design), external flushing valves should be installed. In this case, three-way flushing valves should be used or additional isolation valves must be installed to be able to isolate the loop during flushing. Figure 16b: Multiple Units with Internal Flow Controllers and External Flushing Valves Size for Heat Pump ‘A’ Flow Size for ‘A’ + ‘B’ Flow Size for ‘A’ + ‘B’ + ‘C’ Flow Ground Loop Shut-Off Valve To Ground Loop Heat Pump A Heat Pump B Heat Pump C Indoor Loop Shut-Off Valve Flush Valve Size for Heat Pump ‘C’ Flow Size for Heat Pump ‘B’ Flow Water Out Water Out Water Out Water In Water In Water In First, flush the ground loop. The installer should close the indoor loop shut-off valve (or the internal flushing valves in all units) and open the ground loop shut-off valve to prevent flow through the indoor loop while flushing the ground loop. Once the ground loop is flushed, close the ground loop shut-off valve and open the indoor loop valve(s) to flush the units and indoor piping. Remember that there is an internal check valve in the variable speed pump and that backward flow the unit is not possible. 16 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Multiple Unit Piping and Flushing Multiple Units with Internal Modulating Valves and Central Pump This is an application where multiple units are used in conjunction with a central, variable speed pump. In this case, units with closed loop modulating valves are used (do not use open loop modulating valves on a closed loop system). External flushing valves are required. This application is for larger systems, including commercial. Figure 16c: Multiple Units with Internal Modulating Valves and Central Pump Size for Heat Pump ‘A’ Flow Size for ‘A’ + ‘B’ Flow Ground Loop Shut-Off Valve Size for ‘A’ + ‘B’ + ‘C’ Flow To Ground Loop Pump Heat Pump Heat Pump Heat Pump Size for Heat Pump ‘B’ Flow Pump Isolation Valves Exp Tank Flush Valve Size for Heat Pump ‘C’ Flow Water Out Water Out Water Out Water In Water In Water In Before flushing, the installer should manually open all modulating valves as detailed in Closed Loop – External Central Pumping section of this manual. Next, flush the ground loop. The installer should close a pump isolation valve and open the ground loop shut-off valve to prevent flow through the indoor loop while flushing the ground loop. Once the ground loop is flushed, close the ground loop shut-off valve and open the pump isolation valve to flush the units and indoor piping. Once the system is flushed remember to return the modulating valves to their normal operating position. c l i m a t e m a s t e r. c o m 17 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Ground Loop Heat Pump Applications Antifreeze Selection - General In areas where minimum entering loop temperatures drop below 40°F [4.4°C] or where piping will be routed through areas subject to freezing, antifreeze is needed. Alcohols and glycols are commonly used as antifreeze solutions. Your local representative should be consulted for the antifreeze best suited to your area. Freeze protection should be maintained to 15°F [8.5°C] below the lowest expected entering loop temperature. Initially calculate the total volume of fluid in the piping system using Table 3. Then use the percentage by volume shown in Table 4 for the amount of antifreeze. Antifreeze concentration should be checked from a well mixed sample using a hydrometer to measure specific gravity. Contact your ClimateMaster distributor if you have any questions as to antifreeze selection. WARNING! WARNING! Always use properly marked vehicles (D.O.T. placards), and clean/suitable/properly identified containers for handling flammable antifreeze mixtures. Post and advise those on the jobsite of chemical use and potential dangers of handling and storage. NOTICE: DO NOT use automotive windshield washer fluid as antifreeze. Washer fluid contains chemicals that will cause foaming. CAUTION! Table 3: Fluid Volume Fluid Volume (gal [liters] per 100’ [30 meters) Pipe) Pipe Copper Polyethylene Size Volume (gal) [liters] 1” 4.1 [15.3] 1.25” 6.4 [23.8] 2.5” 9.2 [34.3] 3/4” IPS SDR11 2.8 [10.4] 1” iPS SDR11 4.5 [16.7] 1.25” IPS SDR11 8.0 [29.8] 1.5” IPS SDR11 10.9 [40.7] 2” IPS SDR11 18.0 [67.0] Unit Heat Exchanger Typical 1.0 [3.8] Flush Cart Tank 10” Dia x 3ft tall [254mm x 91.4cm tall] 10 [37.9] WARNING! WARNING! Always dilute alcohols with water (at least 50% solution) before using. Alcohol fumes are flammable and can cause serious injury or death if not handled properly. When handling methanol (or any alcohol), always wear eye protection and rubber gloves as alcohols are easily absorbed through the skin. Table 4: Antifreeze Percentages by Volume Type Methanol Propylene Glycol Ethanol* Minimum Temperature for Low Temperature Protection 10°F [-12.2°C] 15°F [-9.4°C] 20°F [-6.7°C] 25°F [-3.9°C] 21% 29% 23% 17% 24% 20% 13% 18% 16% 8% 12% 11% * Must not be denatured with any petroleum based product 18 CAUTION! Always obtain MSDS safety sheets for all chemicals used in ground loop applications including chemicals used as antifreeze. Antifreeze Charging It is highly recommended to utilize premixed antifreeze fluid where possible to alleviate many installation problems and extra labor. The following procedure is based upon pure antifreeze and can be implemented during the Full Flush procedure with three way valves in the Figure 15d - Valve Position C. If a premixed mixture of 15°F [-9.4°C] freeze protection is used, the system can be filled and flushed with the premix directly to prevent handling pure antifreeze during the installation. 1) Flush loop until all air has been purged from system and pressurize to check for leaks before adding any antifreeze. 2) Run discharge line to a drain and hook up antifreeze drum to suction side of pump (if not adding below water level through approved container). Drain flush cart reservoir down to pump suction inlet so reservoir can accept the volume of antifreeze to be added. 3) Calculate the amount of antifreeze required by first calculating the total fluid volume of the loop from Table 3. Then calculate the amount of antifreeze needed using Table 2 for the appropriate freeze protection level. Many southern applications require freeze protection because of exposed piping to ambient conditions. 4) Isolate unit and prepare to flush only through loop (see Figure 15a). Start flush cart, and gradually introduce the required amount of liquid to the flush cart tank (always introduce alcohols under water or use suction of pump to draw in directly to prevent fuming) until attaining the proper antifreeze protection. The rise in flush reservoir level indicates amount of antifreeze added (some carts are marked with measurements in gallons or liters). A ten inch [25.4 cm] diameter cylinder, 3 foot [91.4 cm] tall holds approximately 8 gallons [30.3 liters] of fluid plus the hoses (approx. 2 gallons, [7.6 liters], which equals about Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Ground Loop Heat Pump Applications Chart 1a: Methanol Specific Gravity Specific Gravity 1.000 0.995 0.990 0.985 0.980 0.975 0.970 0.965 0.960 -50°F -40°F -30°F -20°F -10°F 0°F 10°F 20°F 30°F 40°F 50°F -45.6°C -34.4°C -23.3°C -12.2°C -1.1°C 10°C -40°C -28.9°C -17.8°C -6.7°C 4.4°C Low Temperature Protection Chart 1b: Propylene Glycol Specific Gravity 1.07 Specific Gravity 10 gallons [37.9 liters] total. If more than one tankful is required, the tank should be drained immediately by opening the waste valve of the flush cart noting the color of the discharge fluid. Adding food coloring to the antifreeze can help indicate where the antifreeze is in the circuit and prevents the dumping of antifreeze out the waste port. Repeat if necessary. 5) Be careful when handling methanol (or any alcohol). Always wear eye protection and rubber gloves. The fumes are flammable, and care should be taken with all flammable liquids. Open flush valves to flush through both the unit and the loop and flush until fluid is homogenous and mixed. It is recommended to run the unit in the heating and cooling mode for 15-20 minutes each to ‘temper’ the fluid temperature and prepare it for pressurization. Devoting this time to clean up can be useful. This procedure helps prevent the periodic “flat” loop condition. 6) Close the flush cart return valve; and immediately thereafter, close the flush cart supply valve, leaving a positive pressure in the loop of approximately 50 psi [345 kPa]. This is a good time to pressure check the system as well. Check the freeze protection of the fluid with the proper hydrometer to ensure that the correct amount of antifreeze has been added to the system. The hydrometer can be dropped into the flush reservoir and the reading compared to Chart 1a for Methanol, 1b for Propylene Glycol, and 1c for Ethanol to indicate the level of freeze protection. Do not antifreeze more than a +10°F [-12.2°C] freeze point. Specific gravity hydrometers are available in the residential price list. Repeat after reopening and flushing for a minute to ensure good second sample of fluid. Inadequate antifreeze protection can cause nuisance low temperature lockouts during cold weather. 1.06 1.05 1.04 1.03 1.02 1.01 1.00 -40°F -40°C -30°F -20°F -10°F 0°F 10°F 20°F -34.4°C -28.9°C -23.3°C -17.8°C -12.2°C -6.7°C 30°F 40°F -1.1°C 4.4°C Low Temperature Protection Chart 1c: Ethanol Specific Gravity 1.000 0.995 0.990 0.985 WARNING! 0.980 WARNING! Always dilute alcohols with water (at least 50% solution) before using. Alcohol fumes are flammable and can cause serious injury or death if not handled properly. 5°F 10°F 15°F 20°F 25°F 30°F 35°F -15.0°C -12.2°C -9.4°C -6.7°C -3.9°C -1.1°C 1.7°C Low Temperature Protection Figure 16: Low Temperature Cutout Selection Off LT2 LT2 RV RV CO 12 CO On JW3 S3 Off Off On c1 ay On 1 2 3 4 5 6 7 8 Low Water Temperature Cutout Setting - DXM2 Control When antifreeze is selected, the LT1 jumper (JW3) should be clipped to select the low temperature (antifreeze 10°F [-12.2°C]) set point and avoid nuisance faults (see “Low Water Temperature Cutout Selection” in this manual). 0°F -17.8°C 1 2 3 4 5 6 7 8 7) Close the flush cart return valve; immediately thereafter, close the flush cart supply valve, shut off the flush cart leaving a positive pressure in the loop of approximately 50-75 psi [345-517 kPa]. Refer to Figure 15e for more details. -5°F -20.6°C 1 2 3 4 When handling methanol (or any alcohol), always wear eye protection and rubber gloves as alcohols are easily absorbed through the skin. 0.975 P7 RV Relay CCH Relay 1 24Vdc S2 A0-1 A0-2 S1 EH1 4 EH2 Comp Relay P6 CCG c2 ay P11 AO2 Gnd P10 T1 T2 T2 T3 T3 T4 T4 P9 CC T5 T5 T6 T6 DXM2 PCB JW3-LT1 jumper should be clipped for low temperature operation c l i m a t e m a s t e r. c o m 19 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Closed Loop - External Central Pumping Applications Figure 17: Typical Closed Loop with Central Pumping Application (with Internal Modulating Motorized Valve Shown) To Thermostat Internal Motorized Modulating Valve Water Out Water In High and Low Voltage Knockouts Shut Off Ball Valves for Isolation Vibration Isolation Pad Tranquility Digital packaged units are available with a modulating water valve option for closed-loop applications with external central pumping (designated by a 5 in the 11th position of the unit model number). With this option, the Modulating Valve is regulated by the Communicating DXM2 board based on entering and leaving water temperature (∆T). The DXM2 board outputs a 0-10v signal to determine valve position (flow rate). The modulating valve defaults to closed position if it loses signal but still has 24V power running to it. If the motorized modulating valve loses both signal from the DXM2 board AND 24V power, it will remain in the same position it was in when it lost 24V power. Note: The Cv (flow coefficient) of the valve used in these units is DIFFERENT that the Cv of the valve used in the open loop unit. It is not advisable for use in open loop applications as sound/noise issues may result. Units with the water circuit for closed loop, central pumping option are only available with a copper water coil. while turning the handle to the open position as shown in Figure 18. This fully opens the valve for flushing. Once flushing is complete, press the lock release again and return the valve handle to its normally closed position. Figure 18: Internal Modulating Motorized Valve Positions Sizes 026-049 Closed Closed Open Open /RFN5HOHDVH To manually open the internal modulating motorized water valve in TE026 – 049 push down on the handle to unlock it. Then rotate the handle to the open position as shown in Figure 18. This fully opens the valve for flushing. Once flushing is complete, return the valve handle to its normally closed position. To manually open the internal modulating motorized water valve in TE064 – 072, push down on the lock release button 20 Sizes 064-072 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Open Loop or Ground-Water Heat Pump Applications flushing is complete, press the lock release again and return the valve handle to its normally closed position. Figure 19: Typical Open Loop/Well Application To Thermostat Internal Motorized Modulating Valve Pressure Tank Water Out Water In High and Low Voltage Knockouts Boiler Drains Shut Off Ball Valves for Isolation Optional Filter Vibration Isolation Pad CAUTION! CAUTION! Refrigerant pressure activated water regulating valves should never be used with this equipment. Tranquility® packaged units are available with a water circuit option for open loop applications (designated by a 6 in the 11th position of the unit model number). The Motorized Modulating Valve is regulated by the Communicating DXM2 board based on entering and leaving water temperature (∆T). The DXM2 board gives a 0-10v signal to determine flow rate. The motorized modulating valve defaults to closed position if it loses signal but still has 24V power running to it. If the motorized modulating valve loses both signal from the DXM2 board AND 24V power, it will remain in the same position it was in when it lost 24V power. DO NOT USE open loop units in closed loop applications due to significant pressure drop through the open loop motorized modulating valve. This option is only available with Cupro-Nickel Water Coil. To manually open the internal modulating motorized water valve in TE026 – 049 push down on the handle to unlock it. Then rotate the handle to the open position as shown in Figure 18. This fully opens the valve for flushing. Once flushing is complete, return the valve handle to its normally closed position. To manually open the internal modulating motorized water valve in TE064 – 072, push down on the lock release button while turning the handle to the open position as shown in Figure 18. This fully opens the valve for flushing. Once Open Loop - Ground Water Systems Typical open loop piping is shown in Figure 19. Shut off valves should be included for ease of servicing. Boiler drains or other valves should be “tee’d” into the lines to allow acid flushing of the heat exchanger. Shut off valves should be positioned to allow flow through the coax via the boiler drains without allowing flow into the piping system. Schrader ports built into unit may be used to measure heat exchanger pressure drop. Water temperature can be viewed on the communicating thermostat. Piping materials should be limited to copper, PE, or PVC SCH80. Note: Due to the pressure and temperature extremes, PVC SCH40 is not recommended. Water quantity should be plentiful and of good quality. Consult Table 3 for water quality requirements. vFlow™ units for open loop applications always come with Cupro-Nickel coils. In ground water situations where scaling could be heavy or where biological growth such as iron bacteria will be present, an open loop system is not recommended. Heat exchanger coils may over time lose heat exchange capabilities due to build up of mineral deposits. Heat exchangers must only be serviced by a qualified technician, as acid and special pumping equipment is required. Desuperheater coils can likewise become scaled and possibly plugged. In areas with extremely hard water, the owner should be informed that the heat exchanger may require occasional acid flushing. In some cases, the desuperheater option should not be recommended due to hard water conditions and additional maintenance required. Water Quality Standards Table 3 should be consulted for water quality requirements. Scaling potential should be assessed using the pH/Calcium hardness method. If the pH <7.5 and the Calcium hardness is less than 100 ppm, scaling potential is low. If this method yields numbers out of range of those listed, a monitoring plan should be implemented in these probable scaling situations. Other water quality issues such as iron fouling, corrosion prevention and erosion and clogging should be referenced in Table 3. Pressure Tank and Pump Use a closed, bladder-type pressure tank to minimize mineral formation due to air exposure. The pressure tank should be sized to provide at least one minute continuous run time of the pump using its drawdown capacity rating to prevent pump short cycling. Discharge water from the unit is not contaminated in any manner and can be disposed of in various ways, depending on local building codes (e.g. recharge well, storm sewer, drain field, adjacent stream or pond, etc.). Most local codes forbid the use of sanitary sewer for disposal. Consult your local building and zoning department to assure compliance in your area. c l i m a t e m a s t e r. c o m 21 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Open Loop or Ground-Water Heat Pump Applications The pump should be sized to handle the home’s domestic water load (typically 5-9 gpm [23-41 l/m]) plus the flow rate required for the heat pump. Pump sizing and expansion tank must be chosen as complimentary items. For example, an expansion tank that is too small can cause premature pump failure due to short cycling. Variable speed pumping applications should be considered for the inherent energy savings and smaller pressure tank requirements. Water Coil Low Temperature Limit Setting For all open loop systems the 30°F [-1.1°C] LT1 setting (factory setting-water) should be used to avoid freeze damage to the unit. See “Low Water Temperature Cutout Selection” (Figure 17) in this manual for details on the low limit setting. Table 3: Water Quality Requirements Water Quality Parameter HX Material Closed Recirculating Open Loop and Recirculating Well Scaling Potential - Primary Measurement Above the given limits, scaling is likely to occur. Scaling indexes should be calculated using the limits below pH/Calcium Hardness Method - All pH < 7.5 and Ca Hardness <100ppm Index Limits for Probable Scaling Situations - (Operation outside these limits is not recommended) Scaling indexes should be calculated at 66°C for direct use and HWG applications, and at 32°C for indirect HX use. A monitoring plan should be implemented. Ryznar 6.0 - 7.5 All Stability Index If >7.5 minimize steel pipe use. -0.5 to +0.5 Langelier All If <-0.5 minimize steel pipe use. Based upon 66°C HWG and Saturation Index Direct well, 29°C Indirect Well HX Iron Fouling Iron Fe 2+ (Ferrous) (Bacterial Iron potential) All Iron Fouling All - <0.2 ppm (Ferrous) If Fe2+ (ferrous)>0.2 ppm with pH 6 - 8, O2<5 ppm check for iron bacteria. - <0.5 ppm of Oxygen Above this level deposition will occur . Corrosion Prevention 6 - 8.5 pH All Hydrogen Sulfide (H2S) All Ammonia ion as hydroxide, chloride, nitrate and sulfate compounds All Monitor/treat as needed - 6 - 8.5 Minimize steel pipe below 7 and no open tanks with pH <8 <0.5 ppm At H2S>0.2 ppm, avoid use of copper and copper nickel piping or HX's. Rotten egg smell appears at 0.5 ppm level. Copper alloy (bronze or brass) cast components are OK to <0.5 ppm. - <0.5 ppm Maximum Allowable at maximum water temperature. Maximum Chloride Levels Copper Cupronickel 304 SS 316 SS Titanium - 10$C <20ppm <150 ppm <400 ppm <1000 ppm >1000 ppm 24$C NR NR <250 ppm <550 ppm >550 ppm 38 C NR NR <150 ppm < 375 ppm >375 ppm Erosion and Clogging Particulate Size and Erosion All <10 ppm of particles and a maximum velocity of 1.8 m/s Filtered for maximum 841 micron [0.84 mm, 20 mesh] size. <10 ppm (<1 ppm "sandfree” for reinjection) of particles and a maximum velocity of 1.8 m/s. Filtered for maximum 841 micron 0.84 mm, 20 mesh] size. Any particulate that is not removed can potentially clog components. The ClimateMaster Water Quality Table provides water quality requirements for ClimateMaster coaxial heat exchangers. When water properties are outside of those requirements, an external secondary heat exchanger must be used to isolate the heat pump heat exchanger from the unsuitable water. Failure to do so will void the warranty for the coaxial heat exchanger. Notes: &ORVHG5HFLUFXODWLQJV\VWHPLVLGHQWLILHGE\Dclosed pressurized piping system. 5HFLUFXODWLQJRSHQZHOOVVKRXOGREVHUYHWKHRSHQUHFLUFXODWLQJGHVLJQFRQVLGHUDWLRQV 15Application not recommended. 1RGHVLJQ0D[LPXP 22 Geothermal Heat Pump Systems Rev.: 3/22/2012 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Hot Water Generator The HWG (Hot Water Generator) or desuperheater option provides considerable operating cost savings by utilizing heat energy from the compressor discharge line to help satisfy domestic hot water requirements. The HWG is active throughout the year, providing virtually free hot water when the heat pump operates in the cooling mode or hot water at the COP of the heat pump during operation in the heating mode. Actual HWG water heating capacities are provided in the appropriate heat pump performance data. Heat pumps equipped with the HWG option include a builtin water to refrigerant heat exchanger that eliminates the need to tie into the heat pump refrigerant circuit in the field. The control circuit and pump are also built in for residential equipment. The figure to the left shows a typical example of HWG water piping connections on a unit with built-in circulating pump. This piping layout prevents sludge/debris from the bottom of the tank being pulled into the HWG pump. Typically a single tank of at least 50 gallons (189 liters) is used to limit installation costs and space. However, a dual tank, as shown in the HWG Double Tank Installation Figure, is the preferred system, as it provides the maximum storage and temperate source water to the HWG. It is always advisable to use water softening equipment on domestic water systems to reduce the scaling potential and lengthen equipment life. In extreme water conditions, it may be necessary to avoid the use of the HWG option since the potential cost of frequent maintenance may offset or exceed any savings. Consult Table 3 for scaling potential tests. Typical Single Tank HWG Installation Hot Outlet to home The temperature set point of the HWG is field selectable to 125°F or 150°F . The 150°F set point allows more heat storage from the HWG. For example, consider the amount of heat that can be stored by the HWG when using the 125°F set point, versus the amount of heat that can be generated by the HWG when using the 150°F set point. Shut Off Valve #1 Shut Off Valve #4 Upper element to 120 - 130°F [49 - 54°C] In a typical 50 gallon two-element electric water heater the lower element should be turned down to 100°F, or the lowest setting, to get the most from the HWG. The tank will eventually stratify so that the lower 80% of the tank, or 40 gallons, becomes 100°F (controlled by the lower element). The upper 20% of the tank, or 10 gallons, will be maintained at 125°F (controlled by the upper element). Using a 125°F set point, the HWG can heat the lower 40 gallons of water from 100°F to 125°F, providing up to 8,330 btu’s of heat. Using the 150°F set point, the HWG can heat the same 40 gallons of water from 100°F to 150°F and the remaining 10 gallons of water from 125°F to 150°F, providing a total of up to 18,743 btu’s of heat, or more than twice as much heat as when using the 125°F set point. Cold Inlet Lower element to 100 - 110°F [38 - 43°C] Powered Water Heater Shut-off Valve #3 Shut Off Valve #2 Field supplied 3/4’ brass nipple and ‘T’ Insulated water lines 5/8” OD, 50 ft maximum (one way) [16mm OD, 15 meters maximum] HWG Double Tank Installation Hot Outlet to house Cold Inlet Cold Inlet from Domestic supply Hot Outlet Electric water heaters are recommended. If a gas, propane, or oil water heater is used, a second preheat tank must be installed (HWG Double Tank Installation Figure). If the electric water heater has only a single center element, the dual tank system is recommended to insure a usable entering water temperature for the HWG. Shut-off Valve #1 Upper element to 130°F [54°C] (or owner preference) Shut-off Valve #4 Powered Water Heater Lower element to 120°F [49°C] Unpowered Shut-off Valve #3 Water Heater Shut Off Valve #2 Field Supplied 3/4” brass nipple and “T” Insulated water lines - 5/8” OD, 50 ft maximum (one way) WARNING! [16mm OD, 15 meters maximum] WARNING! A 150°F SETPOINT MAY LEAD TO SCALDING OR BURNS. THE 150°F SET POINT MUST ONLY BE USED ON SYSTEMS THAT EMPLOY AN APPROVED ANTI-SCALD VALVE. c l i m a t e m a s t e r. c o m 23 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Hot Water Generator Installation The HWG is controlled by two sensors and the DXM2 microprocessor control. One sensor is located on the compressor discharge line to sense the discharge refrigerant temperature. The other sensor is located on the HWG heat exchanger’s “Water In” line to sense the potable water temperature. Figure 22: Anti-Scald Valve Piping Connections ANTI-SCALD COLD WATER VALVE PIPING SUPPLY CONNECTIONS CHECK VALVE ANTI-SCALD VALVE WARNING! C HOT WATER TO HOUSE M H 8” MAX WARNING! UNDER NO CIRCUMSTANCES SHOULD THE SENSORS BE DISCONNECTED OR REMOVED. FULL LOAD CONDITIONS CAN DRIVE HOT WATER TANK TEMPERATURES FAR ABOVE SAFE TEMPERATURE LEVELS IF SENSORS DISCONNECTED OR REMOVED. The DXM2 microprocessor control monitors the refrigerant and water temperatures to determine when to operate the HWG. The HWG will operate any time the refrigerant temperature is sufficiently above the water temperature. Once the HWG has satisfied the water heating demand during a heat pump run cycle, the controller will cycle the pump at regular Intervals to determine if an additional HWG cycle can be utilized. When the control is powered and the HWG pump output is active for water temperature sampling or HWG operation, the DXM2 status LED will slowly flash (On 1 second, Off 1 second). WATER HEATER Hot Water Generator settings are determined by DIP switches 3-2, 3-3, and 3-4. If the control has detected a HWG fault, the DXM2 status LED will flash a numeric fault code as follows: DIP 3-2 controls the HWG Test Mode. It provides for forced operation of the HWG output, activating the HWG pump for up to five minutes. ON = HWG test mode, OFF = normal HWG operation. The control will revert to standard operation after five minutes regardless of switch position. High Water Temperature (>160ºF) Hot Water Sensor Fault Compressor Discharge Sensor Fault DIP 3-3 determines HWG set point temperature. It provides for selection of the HWG operating set point. ON = 150°F (66°C), OFF = 125°F (52°C). 5 flashes 6 flashes 6 flashes Fault code flashes have a duration of 0.3 seconds with a 10 second pause between fault codes. For example, a “Compressor Discharge sensor fault” will be six flashes 0.3 seconds long, then a 10 second pause, then six flashes again, etc. DIP 3-4 is for the HWG status. It provides HWG operation control. ON = HWG mode enabled, OFF = HWG mode disabled. Units are shipped from the factory with this switch in the OFF position. Figure *: Hot Water Generator Settings WARNING! R NSB C Alarm Relay Micro U1 JW1 1 HP HP LP LP LT1 LT1 LT2 LT2 RV RV CO 12 CO Fault Status ESD OVR H On JW3 Off On R NO1 NC1 COM1 NO2 NC2 COM2 R Acc1 Relay On 1 2 3 4 5 6 7 8 S3 P3 Off 1 2 3 4 5 6 7 8 Geothermal Heat Pump Systems Off A 1 2 3 4 Hot Water Generator Settings Factory Use WARNING! USING A 150°F SETPOINT ON THE HWG WILL RESULT IN WATER TEMPERATURES SUFFICIENT TO CAUSE SEVERE PHYSICAL INJURY IN THE FORM OF SCALDING OR BURNS, EVEN WHEN THE HOT WATER TANK TEMPERATURE SETTING IS VISIBLY SET BELOW 150°F. THE 150°F HWG SETPOINT MUST ONLY BE USED ON SYSTEMS THAT EMPLOY AN APPROVED ANTI-SCALD VALVE (PART NUMBER AVAS4) AT THE HOT WATER STORAGE TANK WITH SUCH VALVE PROPERLY SET TO CONTROL WATER TEMPERATURES DISTRIBUTED TO ALL HOT WATER OUTLETS AT A TEMPERATURE LEVEL THAT PREVENTS SCALDING OR BURNS! 24 Gnd NC P2 AL2 P7 RV Relay CCH Relay 1 24Vdc S2 A0-1 A0-2 S1 EH1 4 EH2 Comp Relay P6 CCG Acc2 Relay COH P11 COM AO2 Gnd P10 T1 T2 T2 T3 T3 T4 T4 P9 T5 T5 T6 T6 CC Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Hot Water Generator WARNING! WARNING! The HWG pump Is fully wired from the factory. Use extreme caution when working around the microprocessor control as it contains line voltage connections that presents a shock hazard that can cause severe injury or death! The heat pump, water piping, pump, and hot water tank should be located where the ambient temperature does not fall below 50°F [10°C]. Keep water piping lengths at a minimum. DO NOT use a one way length greater than 50 ft. (one way) [15 m]. See Table 4 for recommended piping sizes and maximum lengths. All installations must be in accordance with local codes. The installer is responsible for knowing the local requirements, and for performing the installation accordingly. DO NOT activate the HWG (turn DIP 3-4 to the ON position) until “Initial Start-Up” section, below is completed. Powering the pump before all installation steps are completed will damage the pump. Water Tank Preparation 1. Turn off power or fuel supply to the hot water tank. 2. Connect a hose to the drain valve on the water tank. 3. Shut off the cold water supply to the water tank. 4. Open the drain valve and open the pressure relief valve or a hot water faucet to drain tank. 5. When using an existing tank, it should be flushed with cold water after it is drained until the water leaving the drain hose is clear and free of sediment. 6. Close all valves and remove the drain hose. 7. Install HWG water piping. HWG Water Piping 1. Using at least 1/2” [12.7mm] I.D. copper, route and install the water piping and valves as shown in Figures 20 or 21. Install an approved anti-scald valve if the 150°F HWG setpoint is or will be selected. An appropriate method must be employed to purge air from the HWG piping. This may be accomplished by flushing water through the HWG (as in the figures on page 23) or by installing an air vent at the high point of the HWG piping system. 2. Insulate all HWG water piping with no less than 3/8” [10mm] wall closed cell insulation. 3. Open both shut off valves and make sure the tank drain valve is closed. Water Tank Refill 1. Close valve #4. Ensure that the HWG valves (valves #2 and #3) are open. Open the cold water supply (valve #1) to fill the tank through the HWG piping. This will force water flow through the HWG and purge air from the HWG piping. 2. Open a hot water faucet to vent air from the system until water flows from faucet; turn off faucet. Open valve #4. 3. Depress the hot water tank pressure relief valve handle to ensure that there is no air remaining in the tank. 4. Inspect all work for leaks. 5. Before restoring power or fuel supply to the water heater, adjust the temperature setting on the tank thermostat(s) to insure maximum utilization of the heat available from the refrigeration system and conserve the most energy. On tanks with both upper and lower elements and thermostats, the lower element should be turned down to 100°F [38°C] or the lowest setting; the upper element should be adjusted to 120-130°F [49-54°C]. Depending upon the specific needs of the customer, you may want to adjust the upper element differently. On tanks with a single thermostat, a preheat tank should be used (HWG Double Tank Installation Figure on page 23). 6. Replace access cover(s) and restore power or fuel supply. Initial Start-Up 1. Make sure all valves in the HWG water circuit are fully open. 2. Turn on the heat pump and allow it to run for 10-15 minutes. 3. Set S3-4 to the “ON” position (enabled) to engage the HWG. See Figure *. 4. The HWG pump should not run if the compressor is not running. 5. The temperature difference between the water entering and leaving the HWG coil should be approximately 5-10°F [3-6°C]. 6. Allow the unit to operate for 20 to 30 minutes to insure that it is functioning properly. Table 4: HWG Water Piping Sizes and Length Unit Nominal Tonnage Nominal HWG Flow (gpm) 1/2" Copper (max length*) 3/4" Copper (max length*) 2.0 0.8 50 - 2.5 1.0 50 - 3.0 1.2 50 - 3.5 1.4 50 - 4.0 1.6 45 50 5.0 2.0 25 50 6.0 2.4 10 50 *Maximum length is equivalent length (in feet) one way of type L copper. CAUTION! CAUTION! Use only copper piping for HWG piping due to the potential of high water temperatures for water that has been in the HWG heat exchanger during periods of no-flow conditions (HWG pump not energized). Piping other than copper may rupture due to high water temperature and potable water pressure. c l i m a t e m a s t e r. c o m 25 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Electrical - Line Voltage WARNING! WARNING! To avoid possible injury or death due to electrical shock, open the power supply disconnect switch and secure it in an open position during installation. CAUTION! CAUTION! Use only copper conductors for field installed electrical wiring. Unit terminals are not designed to accept other types of conductors. Table 5a: Tranquility® 22 (TZ) Series Electrical Data with Magna Internal Flow Controller Compressor Model HWG Pump Qty FLA Int Loop Pump FLA Fan Motor FLA Total Unit FLA Min Circuit Amps Max Fuse/ HACR RLA LRA 024 11.7 58.3 1 0.5 1.7 3.9 17.8 20.7 30 030 13.1 73.0 1 0.5 1.7 3.9 19.2 22.4 35 036 15.3 83.0 1 0.5 1.7 3.9 21.4 25.2 40 042 17.9 96.0 1 0.5 1.7 5.2 25.3 29.7 45 048 21.2 104.0 1 0.5 1.7 5.2 28.6 33.9 50 060 27.1 152.9 1 0.5 1.7 6.9 36.2 42.9 70 Rated Voltage of 208-230/60/1 HACR circuit breaker in USA only Min/Max Voltage of 197/254 All fuses Class RK-5 Electrical - Line Voltage All field installed wiring, including electrical ground, must comply with the National Electrical Code as well as all applicable local codes. Refer to the unit electrical data for fuse sizes. Consult wiring diagram for field connections that must be made by the installing (or electrical) contractor. All final electrical connections must be made with a length of flexible conduit to minimize vibration and sound transmission to the building. General Line Voltage Wiring Be sure the available power is the same voltage and phase shown on the unit serial plate. Line and low voltage wiring must be done in accordance with local codes or the National Electric Code, whichever is applicable. Power Connection Line voltage connection is made by connecting the incoming line voltage wires to the “L” side of the contactor as shown in Figure 21. Consult Tables 5a through 5b for correct fuse size. 208 Volt Operation All residential 208-230 Volt units are factory wired for 230 Volt operation. The transformer may be switched to the 208V tap as illustrated on the wiring diagram by switching the red (208V) and the orange (230V) wires at the contactor terminal. Figure 21: Tranquility Single Phase Line Voltage Field Wiring Table 5b: Tranquility® 22 (TZ) Series Electrical Data with Modulating Valve Compressor RLA LRA Qty HWG Pump FLA 024 11.7 58.3 1 0.5 3.9 16.1 19.0 30 030 13.1 73.0 1 0.5 3.9 17.5 20.7 30 036 15.3 83.0 1 0.5 3.9 19.7 23.5 35 042 17.9 96.0 1 0.5 5.2 23.6 28.0 45 048 21.2 104.0 1 0.5 5.2 26.9 32.2 50 060 27.1 152.9 1 0.5 6.9 34.5 41.2 60 Model Rated Voltage of 208-230/60/1 HACR circuit breaker in USA only Fan Motor FLA Total Unit FLA Min Circuit Amps Max Fuse/ HACR Min/Max Voltage of 197/254 All fuses Class RK-5 WARNING! WARNING! Disconnect electrical power source to prevent injury or death from electrical shock. CAUTION! CAUTION! Use only copper conductors for field installed electrical wiring. Unit terminals are not designed to accept other types of conductors. 26 Unit Power Supply (see electrical tables 5a - 5b for minimum circuit amps and maxiumum breaker size) Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Electrical - Low Voltage Wiring Figure 24: Tranquility Low Voltage Field Wiring Table 7: Accessory Relay 2 Configuration DIP 2.4 DIP 2.5 DIP 2.6 ACC2 Relay Option ON ON ON Cycle with compressor OFF ON ON N/A for Residential Applications ON OFF ON Water valve – Slow opening OFF OFF ON Humidifier ON ON OFF Outside air damper All other DIP combinations are invalid Figure *: Accessory Connections Gnd NC P2 AL2 R NSB C Alarm Relay Micro U1 JW1 1 HP HP LP LP LT1 LT1 LT2 LT2 RV RV CO 12 CO Fault Status ESD OVR H Off A On JW3 1 2 3 4 Accessory Terminal Off On 1 2 3 4 5 6 7 8 R NO1 COM1 NO2 NC2 COM2 R Factory Use Accessory Relays NC1 Acc1 Relay On 1 2 3 4 5 6 7 8 S3 P3 Off P7 RV Relay CCH Relay 1 24Vdc S2 A0-1 A0-2 S1 EH1 4 EH2 Comp Relay P6 CCG Acc2 Relay COH P11 COM AO2 Gnd P10 T1 T2 T2 T3 T3 T4 T4 P9 CC T5 T5 T6 T6 Low Voltage Field Wiring Accessory Connections A terminal paralleling the compressor contactor coil has been provided on the DXM2 control. Terminal “A” is designed to control accessory devices. Note: This terminal should be used only with 24 Volt signals and not line voltage. Terminal “A” is energized with the compressor contactor (see Figure 26). The DXM2 controller includes two accessory relays ACC1 and ACC2. Each relay includes a normally open (NO) and a normally closed (NC) contact. Accessory relays may be configured to operate as shown in Tables 8a and 8b. Table 6: Accessory Relay 1 Configuration DIP 2.1 DIP 2.2 DIP 2.3 ACC1 Relay Option ON ON ON Cycle with fan OFF ON ON N/A for Residential Applications ON OFF ON Water valve – Slow opening ON ON OFF Outside air damper OFF ON OFF ClimaDry option – Dehumidistat OFF OFF OFF ClimaDry option – Humidistat OFF OFF ON N/A for Residential Applications ON OFF OFF N/A for Residential Applications All other DIP combinations are invalid c l i m a t e m a s t e r. c o m 27 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Electrical - Thermostat Wiring and Auxiliary Heat Thermostat Installation The thermostat should be located on an interior wall in a larger room, away from supply duct drafts. DO NOT locate the thermostat in areas subject to sunlight, drafts or on external walls. The wire access hole behind the thermostat may in certain cases need to be sealed to prevent erroneous temperature measurement due to air infiltration through the wall cavity. Position the thermostat back plate against the wall so that it appears level and so the thermostat wires protrude through the middle of the back plate. Mark the position of the back plate mounting holes and drill holes with a 3/16” (5mm) bit. Install supplied anchors and secure plate to the wall. Thermostat wire must be 18 AWG or larger wire. Wire the appropriate thermostat as shown in Figures 26a and 26b to the low voltage terminal strip on the DXM2 control board. Practically any heat pump thermostat will work with these units, provided it has the correct number of heating and cooling stages. However, using the communicating thermostat (ATC32U**) is highly recommended for on-site, easier configuration, monitoring and diagnosis. Figure 26a: iGate™ Communicating Thermostat Connection to DXM2 Control ATC32U** Thermostat 24Vac Common C Comm + A+ 24Vac Hot R Comm - B- Outdoor Sensor (Optiona) OD Remote Indoor Sensor (Optiona) ID Figure 26b: Conventional 3 Heat / 2 Cool Thermostat Connection to DXM2 Control Thermostat Compressor Compressor Stage 2 Y1 Auxiliary Heat W DH CAUTION! Refrigerant pressure activated water regulating valves should never be used with ClimateMaster equipment. DXM2 Board Y1 Y2 W H O G R C AL1 Y2 Reversing Valve Fan O 24Vac Hot 24Vac Common Fault LED R C G L Notes: 1) ECM automatic dehumidification mode operates with dehumidification airflows in the cooling mode when the dehumidification output from thermostat is active. Normal heating and cooling airflows are not affected. 2) DXM2 board DIP switch S2-7 must be in the auto dehumidification mode for automatic dehumidification 3) DH connection not possible with units with internal pump. Use ATC32U**. 4) Only use ATC Communicating Thermostat when using Humidifier (H Input) with units with internal flow controller. Auxiliary Heat Installation In both vertical and horizontal configurations, auxiliary electric heater is installed externally to the unit. Fan For installation instructions, refer to the Electric Heat IOM, 97B0005N02. Communicating Thermostat Typical Vertical External Mount Installation Electric Heat Assembly Or Sensors Air Coil Diagnostic Tool Transition bracket between cabinet top and electric heater shipped with TZ036 and 042. Auxiliary electric heat power supply knockout opposite air coil *Low Voltage control Two-Way Communication One-Way Communication Or Mot. Modulating Valve 28 B- GND CAUTION! CAUTION! If communicating thermostat is not installed, a communicating service tool must be used to configure and diagnose this system. Gnd A+ 24V Dehumidification CAUTION! DXM2 Variable Speed Pump Geothermal Heat Pump Systems harness is prewired on all distributor class units. Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N60 Part 1 of 2 This diagram includes typical wiring details but is not applicable to all units. For specific unit wiring, refer to the diagram or the units’ control panel. c l i m a t e m a s t e r. c o m 29 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Wiring Diagram with Internal Flow Controller - 96B0005N60 Part 2 of 2 30 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Wiring Diagram with Motorized Modulating Water Valve 96B0005N62 - Part 1 of 2 This diagram includes typical wiring details but is not applicable to all units. For specific unit wiring, refer to the diagram or the units’ control panel. c l i m a t e m a s t e r. c o m 31 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Wiring Diagram with Motorized Modulating Water Valve 96B0005N62 - Part 2 of 2 32 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B ECM Blower Control The ECM fan is controlled directly by the DXM2 control board that converts thermostat inputs and CFM settings to signals used by the ECM motor controller. To take full advantage of the ECM motor features, an iGate™ communicating multistage thermostat should be used (ATC32U**). The DXM2 control maintains a selectable operating airflow [CFM] for each heat pump operating mode. For each operating mode there are maximum and minimum airflow limits. See the ECM Blower Performance tables for the maximum, minimum, and default operating airflows. Airflow levels are selected using the configuration menus of a communicating thermostat (ATC32U**) or diagnostic tool (ACDU**). The configuration menus allow the installer to independently select and adjust the operating airflow for each of the operating modes. Air flow can be selected in 25 CFM increments within the minimum and maximum limits shown in Table 8. The blower operating modes include: • First Stage Cooling (Y1 & O) • Second Stage Cooling (Y1, Y2, & O) • First Stage Cooling in Dehumidification Mode (Y1, O, & Dehumid) • Second Stage Cooling in Dehumidification Mode (Y1, Y2, O, & Dehumid) • First Stage Heating (Y1) • Second Stage Heating (Y1 & Y2) • Third Stage (Auxiliary) Heating (Y1, Y2, & W) • Emergency Heating (W with no Y1 or Y2) • Fan (G with no Y1, Y2, or W) Special Note for AHRI Testing: To achieve rated airflow for AHRI testing purposes, it is necessary to change the CFM settings to rated airflow. Figure 25: Airflow Configuration Screen on Communicating Thermostat AIRFLOW SELECTION HEAT STAGE 1 HEAT STAGE 2 AUXILIARY HEAT EMERGENCY HEAT COOL STAGE 1 COOL STAGE 2 COOL DEHUMID 1 COOL DEHUMID 2 CONTINUOUS FAN HEAT OFF DELAY COOL OFF DELAY PREVIOUS CFM 600 750 850 850 525 700 425 550 350 60 30 NEXT It is necessary to use the ATC32U** communicating thermostat to engage the Auto Dehumidification feature on units with Internal Flow Controllers. Units with Internal Flow Controllers utilize the ‘H’ terminal on the DXM2 as an input for an ambient temperature switch. Units without the Internal Flow Controller option use the ‘H’ terminal on the DXM2 controller to initiate the Auto Dehumidification mode. Refer to the DXM2 AOM for more information (part #97B0003N15). The ECM motor includes “soft start” and “ramp down” features. The soft start feature is a gentle increase of motor rpm at blower start up. This creates a much quieter blower start cycle. The ramp down feature allows the blower to slowly decrease rpm to a full stop at the end of each blower cycle. This creates a much quieter end to each blower cycle and adds overall unit efficiency. The ramp down feature is eliminated during an ESD (Emergency Shut Down) situation. When the DXM2 ESD input is activated, the blower and all other control outputs are immediately de-activated. The duration of the “ramp down” periods are adjustable from 0 seconds to 255 seconds. This adjustment is available in the Aiflow Selection screen using the communicating thermostat or configuration/diagnostics tool, see Figure 27. c l i m a t e m a s t e r. c o m 33 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B ECM Blower Performance Data Table 6: Tranquility® 22 (TZ) Series ECM Blower Performance Data Table Airflow in CFM with wet coil and clean air filter Model Max ESP (in. wg) Fan Motor (hp) Cooling Mode Range Default 024 030 036 042 048 060 0.75 0.5 0.6 0.6 0.75 0.75 1/2 1/2 1/2 3/4 3/4 1 Dehumid Mode Stg 2 Stg 1 Stg 2 Stg 1 Stg 2 Stg 1 Fan Only Mode 750 575 650 500 750 575 350 Aux/ Emerg Mode 750 Maximum 850 650 800 600 850 850 850 850 Minimum 600 450 600 450 600 450 300 650 Default 950 650 800 575 950 650 450 950 Maximum 1100 750 1000 700 1100 1100 1100 1100 Minimum 750 525 750 525 750 525 375 750 Default 1125 750 975 650 1125 750 525 1125 Maximum 1250 950 1200 800 1250 1250 1250 1250 Minimum 900 600 900 600 900 600 450 900 Default 1300 925 1125 825 1300 925 600 1300 Maximum 1475 1100 1400 1000 1475 1475 1475 1475 Minimum 1050 750 1050 750 1050 750 525 1050 Default 1500 1125 1300 975 1500 1125 700 1500 Maximum 1700 1300 1600 1200 1700 1700 1700 1700 Minimum 1200 900 1200 900 1200 900 600 1350 Default 1875 1500 1625 1300 1875 1500 875 1875 Maximum 2100 1700 2000 1600 2100 2100 2100 2100 Minimum 1500 1200 1500 1200 1500 1200 750 1500 Airflow is controlled within 5% up to the Max ESP shown with wet coil Factory shipped on default CFM 34 Heating Mode Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Controls DXM2 iGate™ Controller DXM2 is the next generation in controls and is capable of 2-way communication with smart components, like the communicating iGate™ thermostat, ECM fan motor, Magna Variable-Speed Pump and configuration/diagnostic tool. For most residential applications, configuration, monitoring and diagnostics can all be done from the thermostat/ service tool so there’s no need to read LEDs and change DIP switches. For details on user settings, refer to iGate™ Communicating Thermostat User Manual (part # 97B0055N02). For details on Installer settings (not to be used by consumers), refer to iGate™ Communicating Thermostat Installer manual (part # 97B0055N03). For details on installer/service settings on the iGate™ configuration/diagnostic tool, refer to operation manual (part # 97B0106N01). For further details on the DXM2 control, refer to the DXM2 Application, Operation and Maintenance Manual (part # 97B0003N15). The DXM2 AOM is shipped with each unit. Thermostat compatibility It is strongly recommended that iGate™ communicating thermostat (ATC32U**) or iGate™ configuration/ diagnostic tool (ACDU**) be used with DXM2 control, to ensure easy configuration, monitoring and diagnostics, in PLAIN English. For example, Airflow CAN NOT be configured without either the communicating thermostat or configuration/ diagnostic tool Field Hardware Configuration Options - Note: In the following field hardware configuration options, changes should be made ONLY when power is removed from the DXM2 control. settings on Residential units. All DIP switches in S1 and S2 should be “on”. In S3, S3-1 should be “on” and the rest should be “off”. For more details on DIP switches, refer to the DXM2 AOM (part # 97B0003N15). DXM2 Control Start-up Operation The control will not operate until all inputs and safety controls are checked for normal conditions. The compressor will have a 5 minute anti-short cycle delay at power-up. The first time after power-up that there is a call for compressor, the compressor will follow a 5 to 80 second random start delay. After the random start delay and anti-short cycle delay, the compressor relay will be energized. On all subsequent compressor calls, the random start delay is omitted. Test Mode Button Test mode allows the service technician to check the operation of the control in a timely manner. By momentarily pressing the TEST push button, the DXM2 control enters a 20 minute test mode period in which all time delays are sped up 15 times. Figure 26b: Test Mode Button Gnd B- N.C. N.O. N.O. Fan Enable Pust test button to enter Test Mode and speed-up timing and delays for 20 minutes. Fan Speed P8 Test 12V IN OUT Gnd NC P12 Table 7: Unit Operation A0-2: Configure Modulating Valve or Variable-Speed Pump (Internal water flow Models Only) 1 DIP Switches – There’s no need to change the DIP switches 2 CAUTION! Do not restart units without inspection and remedy of faulting condition. Equipment damage may occur. (240Vac) (240Vac) Com Conventional T-stat signal (Non-Communicating) ECM fan G Fan only G, Y1 Stage 1 heating 1 G, Y1, Y2 Stage 2 heating 1 G, Y1, Y2, W Stage 3 heating Not Clipped = 30°F [-1°C]. Clipped = 10°F [-12°C]. CAUTION! P4 P5 Water coil low temperature limit setting: Jumper 3 (JW3LT1 Low Temp) provides field selection of temperature limit setting for LT1 of 30°F or 10°F [-1°F or -12°C] (refrigerant temperature). A0-2 jumper (Figure 29) Factory Set to “IOV” if using Internal Modulating Motorized Valve or “PMW” if using Internal Variable-Speed Pump. This applies only to units with Internal Water Flow Control. A+ 24V Unit 1 G, W Emergency heat G, Y1, O Stage 1 cooling G, Y1, Y2, O Stage 2 cooling 2 2 Stage 1 = 1st stage compressor, 1st stage fan operation Stage 2 = 2nd stage compressor, 2nd stage fan operation Stage 3 = 2nd stage compressor, auxiliary electric heat, 3rd stage fan operation Stage 1 = 1st stage compressor, 1st stage fan operation, reversing valve Stage 2 = 2nd stage compressor, 2nd stage fan operation, reversing valve c l i m a t e m a s t e r. c o m 35 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Layout and Connections Figure 25: LT1 Limit Setting Low Water Temperature Cutout Selection The DXM2 control allows the field selection of low water (or water-antifreeze solution) temperature limit by clipping jumper JW3, which changes the fault cutout temperature associated with thermistor LT1. Note that the LT1 thermistor is located on the refrigerant line between the coaxial heat exchanger and expansion device (TXV). Therefore, LT1 is sensing refrigerant temperature, not water temperature, which is a better indication of how water flow rate/ temperature is affecting the refrigeration circuit. Off LT2 LT2 RV RV CO 12 CO On 1 2 3 4 JW3 Off On 1 2 3 4 5 6 7 8 S3 Off On 1 2 3 4 5 6 7 8 c1 ay P7 RV Relay CCH Relay 1 24Vdc S2 A0-1 A0-2 EH1 4 EH2 S1 P6 Comp Relay CCG c2 The factory setting for LT1 is for systems using water ay CC (30°F [-1.1°C] refrigerant temperature cutout or fallout). In P10 P9 P11 low water temperature (extended range) applications with T5 T5 T6 T6 AO2 Gnd T1 T2 T2 T3 T3 T4 T4 antifreeze (most ground loops), jumper JW3 should be clipped as shown in Figure 25 to change the setting to 10°F DXM2 PCB [-12.2°C] refrigerant cutout or fallout temperature, a more JW3-LT1 jumper should be clipped suitable temperature when using an antifreeze solution. for low temperature (antifreeze) operation All residential units include water/refrigerant circuit Figure 29: DXM2 Layout and Connections insulation to prevent internal Service tool Communicating condensation, which is connection stat connection required when operating with entering water temperatures P4 C Gnd B- A+ 24V (240Vac) below 59°F [15°C]. (240Vac) P1 N.O. Com Y2 Conventional stat connection N.C. N.O. P5 R Y1 Fan Enable Fan Speed W O G P8 R Test C 12V IN OUT Gnd NC P12 AL1 P2 AL2 R Cabinet temperature sensor (with variable speed pump) NSB C Alarm Relay Micro U1 JW1 1 HP HP LP LP LT1 LT1 LT2 LT2 RV RV CO 12 CO Fault Status ESD OVR H Off A JW3 1 2 3 4 Off On R NO1 COM1 NO2 NC2 COM2 R Factory Use Accessory relays refer to DXM2 AOM for configuration NC1 Acc1 Relay 1 24Vdc S2 A0-1 A0-2 P11 AO2 Gnd Electric heat connection P6 Comp Relay P10 P9 T1 T2 T2 T3 T3 T4 T4 CC Configure modulating valve or variable speed pump T5 T5 T6 T6 Compressor Discharge temperature Entering Hot water Temperature Leaving air temp Leaving water temp Entering water temp Variable speed pump Geothermal Heat Pump Systems Factory low voltage molex connection for unit harness EH1 Acc2 Relay COH Water Coil Low Temp Limit Setting. JWT-LT1 jumper should be clipped for low temp (antifreeze) operation 4 EH2 CCG COM ECM Motor Connection P7 RV Relay CCH Relay S1 24V to compressor second-stage solenoid for Y2/full load capacity 36 On 1 2 3 4 5 6 7 8 S3 P3 Off 1 2 3 4 5 6 7 8 Communications and HWG Settings On Test Button to Speed up Time Delays Use 4 mounting screws #6 sheet metal screw 1” long Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Commissioning And Operating Conditions Operating Limits Environment – Units are designed for indoor installation only. Never install units in areas subject to freezing or where humidity levels could cause cabinet condensation (such as unconditioned spaces subject to 100% outside air). Power Supply – Voltage utilization shall comply with AHRI standard 110. Determination of operating limits is dependent primarily upon three factors: 1) return air temperature. 2) water temperature, and 3) ambient temperature. When any one of these factors is at minimum or maximum levels, the other two factors should be at normal levels to insure proper unit operation. Extreme variations in temperature and humidity and/or corrosive water or air will adversely affect unit performance, reliability, and service life. Consult Table 9a for operating limits. Table 9a: Building Operating Limits Operating Limits Air Limits Min. ambient air, DB Rated ambient air, DB Max. ambient air, DB Min. entering air, DB/WB Rated entering air, DB/WB Max. entering air, DB/WB Water Limits Min. entering water Normal entering water Max. entering water Normal Water Flow Unit Cooling Heating 45ºF [7ºC] 80.6ºF [27ºC] 130ºF [54ºC] 65/45ºF [18/7ºC] 70/50ºF Reheat 80.6/66.2ºF [27/19ºC] 100/75ºF [38/24ºC] 39ºF [4ºC] 68ºF [20ºC] 85ºF [29ºC] 50ºF [10ºC] 68ºF [20ºC] 80ºF [27ºC] 20ºF [-6.7ºC] 20ºF [-6.7ºC] 50-110ºF [10-43ºC] 30-70ºF [-1 to 21ºC] 120ºF [49ºC] 120ºF [49ºC] 1.5 to 3.0 gpm / ton [1.6 to 3.2 l/m per kW] Commissioning Conditions Consult Table 9b for commissioning conditions. Starting conditions vary depending upon model and are based upon the following notes: Notes: 1. Conditions in Table 9b are not normal or continuous operating conditions. Minimum/maximum limits are start-up conditions to bring the building space up to occupancy temperatures. Units are not designed to operate under these conditions on a regular basis. 2. Voltage utilization complies with AHRI Standard 110. Table 9b: Building Commissioning Limits Commissioning Limits Air Limits Min. ambient air, DB Rated ambient air, DB Max. ambient air, DB Min. entering air, DB/WB Rated entering air, DB/WB Max. entering air, DB/WB Water Limits Min. entering water Normal entering water Max. entering water Normal Water Flow Unit Cooling Heating 45ºF [7ºC] 80.6ºF [27ºC] 130ºF [54ºC] 60ºF [16ºC] 80.6/66.2ºF [27/19ºC] 110/83ºF [43/28ºC] 39ºF [4ºC] 68ºF [20ºC] 85ºF [29ºC] 40ºF [4.5ºC] 68ºF [20ºC] 80ºF [27ºC] 20ºF [-6.7ºC] 20ºF [-6.7ºC] 50-110ºF [10-43ºC] 30-70ºF [-1 to 21ºC] 120ºF [49ºC] 120ºF [49ºC] 1.5 to 3.0 gpm / ton [1.6 to 3.2 l/m per kW] c l i m a t e m a s t e r. c o m 37 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Start-Up and Operating Conditions Unit and System Checkout BEFORE POWERING SYSTEM, please check the following: UNIT CHECKOUT Shutoff valves: Insure that all isolation valves are open. Line voltage and wiring: Verify that voltage is within an acceptable range for the unit and wiring and fuses/ breakers are properly sized. Verify that low voltage wiring is complete. Unit control transformer: Insure that transformer has the properly selected voltage tap. Residential 208-230V units are factory wired for 230V operation unless specified otherwise. Loop/water piping is complete and purged of air. Water/ piping is clean. Antifreeze has been added if necessary. Entering water and air: Insure that entering water and air temperatures are within operating limits of Tables 10a and 10b. Low water temperature cutout: Verify that low water temperature cut-out on the DXM2 control is properly set. Unit fan: Manually rotate fan to verify free rotation and insure that blower wheel is secured to the motor shaft. Be sure to remove any shipping supports if needed. DO NOT oil motors upon start-up. Fan motors are preoiled at the factory. Check unit fan CFM selection and compare to design requirements. Condensate line: Verify that condensate trap is installed and pitched. HWG is switched off at SW 3-4 unless piping is completed and air has been purged from the system. Unit air coil and filters: Insure that filter is clean and accessible. Clean air coil of all manufacturing oils. Unit controls: Verify that DXM2 field selection options are properly set. Low voltage wiring is complete. Blower CFM and Water ∆T is set on communicating thermostats or diagnostic tool. Service/access panels are in place. SYSTEM CHECKOUT System water temperature: Check water temperature for proper range and also verify heating and cooling set points for proper operation. System pH: Check and adjust water pH if necessary to maintain a level between 6 and 8.5. Proper pH promotes system longevity (see Table 5). System flushing: Verify that all air is purged from the system. Air in the system can cause poor operation or system corrosion. Water used in the system must be potable quality initially and clean of dirt, piping slag, and strong chemical cleaning agents. Some antifreeze solutions may require distilled water. Internal Flow Controller: Verify that it is purged of air and in operating condition. System controls: Verify that system controls function and operate in the proper sequence. Low water temperature cutout: Verify that low water temperature cut-out controls are set properly (LT1 - JW3). 38 Miscellaneous: Note any questionable aspects of the installation. CAUTION! CAUTION! Verify that ALL water valves are open and allow water flow prior to engaging the compressor. Freezing of the coax or water lines can permanently damage the heat pump. CAUTION! CAUTION! To avoid equipment damage, DO NOT leave system filled in a building without heat during the winter unless antifreeze is added to the water loop. Heat exchangers never fully drain by themselves and will freeze unless winterized with antifreeze. Unit Start-up Procedure 1. Turn the thermostat fan position to “ON.” Blower should start. 2. Turn Blower off. 3. Ensure all valves are adjusted to their full open position. Ensure line power to the heat pump is on. 4. Room temperature should be within the minimummaximum ranges of listed in the unit IOM. During startup checks, loop water temperature entering the heat pump should be between 30°F [-1°C] and 95°F [35°C]. 5. It is recommended that water-to-air units be first started in the cooling mode, when possible. This will allow liquid refrigerant to flow through the filter-drier before entering the TXV, allowing the filter-drier to catch any debris that might be in the system before it reaches the TXV. 6. Two factors determine the operating limits of geothermal heat pumps, (a) return air temperature, and (b) entering water temperature. When either of the factors is at a minimum or maximum level, the other factor must be at normal levels to insure proper unit operation. a. Place the unit in Manual Operation. When in manual mode activate Y1,Y2, and O to initiate the cooling mode. Also manually increase CFM until desired cooling CFM is achieved. Next adjust pump speed % until desired loop temperature difference (leaving water temperature minus entering water temperature) is achieved. (For modulating valve adjust valve %). INSTALLER SETTINGS THERMOSTAT CONFIG SYSTEM CONFIG ACCESSORY CONFIG INPUT DEALER INFO HUMIDITY CONFIG TEMPERATURE ALGORITHM DEMAND REDUCTION CNFG SERVICE MODE RESTORY DEFAULTS ATC32U01 SELECT OPTION PREVIOUS Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Start-Up Procedure SERVICE MODE a. Go into Manual Mode activate Y1, and Y2 for Heating. Also manually increase CFM until desired heating CFM is achieved. Next adjust pump speed % until desired loop temperature difference (entering water temperature minus leaving water temperature) is achieved. (For modulating valve adjust valve %). b. Check for warm air delivery at the unit grille within a few minutes after the unit has begun to operate. MANUAL OPERATION CONTROL DIAGNOSTICS DIPSWITCH CONFIG FAULT HISTORY CLEAR FAULT HISTORY SELECT OPTION PREVIOUS SELECT MANUAL OPERATING MODE Y1 Y2 W O G H DH ECM PUMP TEST COMM OUTPUT COMM OUTPUT COMM OUTPUT COMM OUTPUT COMM OUTPUT COMM OUTPUT COMM OUTPUT AIRFLOW SPEED MODE SELECT OPTION PREVIOUS NOTE: Units have a five minute time delay in the control circuit that can be bypassed on the DXM2 control board by placing the unit in the “Test” mode as shown in the unit IOM. Check for normal air temperature rise of 20°F to 30°F (heating mode). OFF OFF OFF OFF OFF OFF OFF 0 0% OFF SELECT b. Check for cool air delivery at the unit grille within a few minutes after the unit has begun to operate. NOTE: Units have a five minute time delay in the control circuit that can be bypassed on the DXM2 control board by placing the unit in the “Test” mode as shown in the unit IOM. Check for normal air temperature drop of 15°F to 25°F (cooling mode). c. Verify that the compressor is on and that the water temperature rise (cooling mode) is within normal range. 9 - 12 20 - 26 d. Check the elevation and cleanliness of the condensate lines. Dripping may be a sign of a blocked line. Check that the condensate trap is filled to provide a water seal. e. Turn thermostat to “OFF” position. A hissing noise indicates proper functioning of the reversing valve. 7. Allow five (5) minutes between tests for pressure to equalize before beginning heating test. 4-8 10 - 17 c. Verify that the compressor is on and that the water temperature fall (heating mode) is within normal range. e. Check for vibration, noise, and water leaks. 8. If unit fails to operate properly, perform troubleshooting analysis (see troubleshooting section in the unit IOM). If the check described fails to reveal the problem and the unit still does not operate, contact a trained service technician to insure proper diagnosis and repair of the equipment. 9. When testing is complete, exit the Installer Menu and set thermostat to maintain desired comfort level for normal operation. 10. BE CERTAIN TO FILL OUT AND RETURN ALL WARRANTY REGISTRATION PAPERWORK. Unit performance may be verified by calculating the unit heat of rejection and heat of extraction. Heat of Rejection (HR) can be calculated and compared to the performance data pages in this IOM. The formula for HR is as follows: HR = TD x GPM x 500 (or 485 for anti-freeze solutions), where TD is the temperature difference between the entering and leaving water, and GPM is the flow rate in U.S. GPM determined by comparing the unit heat exchanger pressure drop to Table 12. Heat of Extraction (HE) can also be calculated and compared to the performance data pages in this IOM. The formula for HE is as follows: HE = TD x GPM x 500 (or 485 for antifreeze solutions), where TD is the temperature difference between the entering and leaving water, and GPM is the flow rate in U.S. GPM determined by comparing the unit heat exchanger pressure drop to Table 12. c l i m a t e m a s t e r. c o m 39 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Start-Up Procedure If performance during any mode appears abnormal, refer to the DXM2 section or troubleshooting section of this manual. NOTE: To obtain maximum performance, the air coil should be cleaned before start-up. A 10% solution of dishwasher detergent and water is recommended. WARNING! WARNING! When the disconnect switch is closed, high voltage is present in some areas of the electrical panel. Exercise caution when working with energized equipment. 40 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Operating Conditions Table 10: TZ Coax Water Pressure Drop Table 11: Water Temperature Change Through Heat Exchanger Pressure Drop (psi) Model GPM 024 Rev B 2.5 3.0 3.8 4.5 6.0 30°F* 0.8 1.2 1.8 2.7 3.9 50°F 0.3 0.6 1.1 1.6 2.8 70°F 0.2 0.5 0.9 1.2 2.2 90°F 0.2 0.5 0.8 1.2 2.0 030 3.0 3.8 4.5 6.0 7.5 1.7 2.3 2.7 3.8 5.1 0.9 1.2 1.6 2.4 3.5 0.8 1.1 1.4 2.2 3.1 0.8 1.1 1.4 2.1 2.9 036 Rev B 4.0 6.0 6.8 8.0 9.0 0.6 1.8 2.3 3.2 4.0 0.1 1.0 1.5 2.2 2.9 0.1 0.7 1.1 1.8 2.4 0.1 0.7 1.1 1.7 2.3 042 3.8 5.3 7.5 7.9 10.5 1.7 2.7 4.5 4.8 7.4 1.0 1.8 3.1 3.4 5.4 0.9 1.6 2.8 3.1 4.9 0.9 1.5 2.6 2.9 4.7 048 4.5 6.0 6.8 9.0 12.0 1.4 2.0 2.5 4.0 6.5 1.1 1.7 2.1 3.4 5.5 0.9 1.4 1.8 3.0 4.9 0.8 1.3 1.7 2.7 4.5 060 Rev B 6.0 7.5 9.0 12.0 15.0 1.2 2.1 3.1 5.4 8.1 0.9 1.7 2.5 4.6 7.0 0.8 1.5 2.3 4.2 6.4 0.8 1.4 2.2 3.9 6.1 9 - 12 4-8 20 - 26 10 - 17 * Based on 15% methanol antifreeze solution Table 12: Antifreeze Correction Antifreeze Type Water Propylene Glycol Methanol Ethanol Ethylene Glycol Antifreeze % Cooling Heating EWT 90°F EWT 30°F WPD Corr. Fct. EWT 30°F Total Cap Sens Cap Power Htg Cap Power 0 1.000 1.000 1.000 1.000 1.000 5 0.995 0.995 1.003 0.989 0.997 1.070 15 0.986 0.986 1.009 0.968 0.990 1.210 25 0.978 0.978 1.014 0.947 0.983 1.360 5 0.997 0.997 1.002 0.989 0.997 1.070 15 0.990 0.990 1.007 0.968 0.990 1.160 25 0.982 0.982 1.012 0.949 0.984 1.220 5 0.998 0.998 1.002 0.981 0.994 1.140 15 0.994 0.994 1.005 0.944 0.983 1.300 25 0.986 0.986 1.009 0.917 0.974 1.360 5 0.998 0.998 1.002 0.993 0.998 1.040 15 0.994 0.994 1.004 0.980 0.994 1.120 25 0.988 0.988 1.008 0.966 0.990 1.200 c l i m a t e m a s t e r. c o m 1.000 41 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Operating Conditions - TZ Table 13: TZ Series Typical Unit Operating Pressures and Temperatures 024 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton 30* 1.5 2.25 3 50 70 90 110 Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Full Load Heating - without HWG active Air Temp Drop °F DB 1.5 2.25 3 1.5 2.25 3 1.5 2.25 3 127-137 125-135 124-134 132-142 131-141 130-140 140-150 139-149 138-148 244-264 240-160 237-257 322-342 325-345 329-349 410-430 427-447 444-464 9-14 10-15 11-16 8-13 9-14 9-14 6-11 6-11 7-12 13-18 11-16 8-13 14-19 12-17 10-15 15-20 13-18 11-16 20.6-22.6 15.6-17.6 11.4-13.4 20-22 14.8-16.8 9.6-11.6 19.9-21.9 14.6-16.6 9.4-11.4 19-25 19-25 19-25 18-24 18-24 18-24 17-23 17-23 17-23 1.5 2.25 3 144-154 143-153 143-153 490-510 500-520 513-533 5-10 5-10 5-10 16-21 14-19 13-18 19.8-21.8 14.45-16.45 9-11 16-22 16-22 16-22 Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 67-77 72-82 77-87 305-325 310-330 314-334 6-11 6-11 6-11 6-11 7-12 7-12 8.0-10.0 5.9-7.9 3.8-5.8 19-25 19-25 19-25 98-108 104-114 111-121 129-139 137-147 145-155 162-172 170-180 178-188 346-366 350-370 355-375 384-404 390-410 397-417 421-441 430-450 440-460 9-14 9-14 9-14 11-16 11-16 11-16 14-19 14-19 14-19 8-13 7-12 6-11 10-15 7-12 6-11 8-13 8-13 8-13 11.1-13.1 8.1-10.1 5.2-7.2 14.4-16.4 10.5-12.5 6.5-8.5 17.5-19.5 12.7-14.7 9-11 26-32 26-32 27-33 32-38 33-39 34-40 39-45 39-45 41-47 *Based on 15% Methanol antifreeze solution 030 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton Suction Pressure PSIG Discharge Pressure PSIG 30* 1.5 2.25 3 50 1.5 2.25 3 122-132 121-131 121-131 240-260 213-233 186-206 10-15 11-16 11-16 11-16 9-14 7-12 19.5-21.5 15.0-17.0 10.3-12.3 70 1.5 2.25 3 122-132 121-131 121-131 316-336 298-318 280-300 9-14 9-14 9-14 12-17 11-16 9-14 90 1.5 2.25 3 133-143 133-143 132-142 438-458 420-440 401-421 8-13 8-13 8-13 110 1.5 2.25 3 137-147 136-146 135-145 507-527 490-510 473-493 6-11 7-12 7-12 Superheat Full Load Heating - without HWG active Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 65-75 67-77 72-82 311-331 315-335 319-339 9-14 9-14 9-14 9-14 9-14 9-14 8.0-10.0 6.2-8.2 4.3-6.3 19-24 20-25 21-26 18-23 19-24 19-24 95-105 100-110 105-115 353-373 358-378 362-382 11-16 11-16 12-17 10-15 10-15 10-15 10.5-12.5 8.2-10.2 5.8-7.8 26-31 26-31 27-32 18.8-20.8 14.3-16.3 9.8-11.8 17-22 17-22 17-22 124-134 130-140 137-147 390-410 398-418 405-425 13-18 14-19 15-20 10-15 9-14 9-14 13.5-15.5 10.5-12.5 7.5-9.5 33-38 33-38 34-39 14-19 13-18 11-16 17.8-19.8 13.5-15.5 9.2-11.2 15-20 15-20 15-20 156-166 163-173 170-180 430-450 459-479 448-468 16-21 17-22 18-23 8-13 8-13 8-13 16.5-18.5 12.8-14.8 9.0-11.0 37-42 39-44 40-45 16-21 14-19 13-18 17.2-19.2 13.0-15.0 8.8-10.8 15-20 15-20 15-20 Subcooling Water Temp Rise °F Air Temp Drop °F DB *Based on 15% Methanol antifreeze solution 036 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton Suction Pressure PSIG Discharge Pressure PSIG 30* 1.5 2.25 3 50 1.5 2.25 3 123-133 122-132 121-131 232-252 232-252 232-252 11-16 12-17 13-18 12-17 10-15 7-12 19.9-21.9 14.3-16.3 9.6-11.6 70 1.5 2.25 3 128-138 124-134 119-129 310-330 290-310 270-290 10-15 10-15 11-16 11-16 10-15 8-13 90 1.5 2.25 3 135-145 134-144 132-142 420-440 410-430 390-410 7-12 8-13 8-13 110 1.5 2.25 3 139-149 138-148 137-147 490-510 480-500 470-490 6-11 6-11 6-11 Superheat Full Load Heating - without HWG active Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 60-70 65-75 70-80 315-335 319-339 325-345 6-11 6-11 6-11 11-16 11-16 11-16 10.0-12.0 6.7-8.7 3.4-5.4 18-23 19-24 20-25 19-24 19-24 19-24 88-98 96-106 105-115 353-373 361-381 370-390 9-14 10-15 10-15 14-19 14-19 14-19 13.2-15.2 9.0-11.0 4.8-6.8 24-29 25-30 26-31 19-21 14.1-16.1 9.2-11.2 18-23 18-23 18-23 116-126 128-138 139-149 390-410 406-426 419-439 11-16 12-17 14-19 15-20 15-20 15-20 17.0-19.0 11.6-13.6 6.1-8.1 29-34 31-36 32-37 11-16 9-14 8-13 18.1-20.1 13.4-15.4 8.7-10.7 17-22 17-22 17-22 148-158 160-170 173-183 436-456 451-471 466-486 14-19 16-21 17-22 15-20 15-20 15-20 20.9-22.9 14.2-16.2 7.4-9.4 35-40 37-42 39-44 10-15 9-14 8-13 17.8-19.8 13.2-15.2 8.6-10.6 16-21 16-21 16-21 Subcooling Water Temp Drop °F Air Temp Drop °F DB *Based on 15% Methanol antifreeze solution 42 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Unit Operating Conditions - TZ Table 13: TZ Series Typical Unit Operating Pressures and Temperatures: Continued 042 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton Suction Pressure PSIG Discharge Pressure PSIG 30* 1.5 2.25 3 50 1.5 2.25 3 121-131 120-130 120-130 230-250 200-240 164-184 10-15 11-16 11-16 10-15 8-13 6-11 20.5-22.5 15.2-17.2 9.8-11.8 70 1.5 2.25 3 127-137 125-135 125-135 305-325 290-310 263-283 8-13 9-13 10-15 10-15 9-14 7-12 90 1.5 2.25 3 133-143 132-142 132-142 426-446 406-426 390-410 7-12 7-12 7-12 110 1.5 2.25 3 137-147 136-146 136-146 494-514 477-497 460-480 5-10 6-11 6-11 Superheat Full Load Heating - without HWG active Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 64-74 67-77 71-81 314-334 317-337 321-341 6-11 6-11 7-12 9-14 9-14 9-14 8.0-10.0 6.0-8.0 4.0-6.0 20-25 20-25 21-26 22-27 22-27 22-27 95-105 100-110 104-114 351-371 356-376 361-381 8-13 9-14 10-15 9-14 9-14 9-14 10.7-12.7 8.1-10.1 5.4-7.4 26-31 27-32 27-32 19.8-21.8 14.7-16.7 9.5-11.5 20-25 21-26 21-26 124-134 131-141 138-148 386-406 390-410 400-420 11-16 12-17 13-18 8-13 8-13 7-12 13.8-15.8 10.4-12.4 7.0-9.0 32-37 33-37 34-39 11-16 9-14 8-13 19-21 14-16 9-11 19-24 19-24 19-24 157-167 164-174 172-182 423-443 432-452 441-461 13-18 15-20 16-21 5-10 5-10 5-10 16.8-18.8 12.7-14.7 8.5-10.5 38-43 40-45 41-46 11-16 10-15 8-13 18-20 14-16 9-11 18-23 18-23 18-23 Subcooling Water Temp Rise °F Air Temp Drop °F DB *Based on 15% Methanol antifreeze solution 048 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton Suction Pressure PSIG Discharge Pressure PSIG 30* 1.5 2.25 3 50 1.5 2.25 3 124-134 123-133 121-131 250-270 212-232 173-193 11-16 12-17 13-18 13-18 10-15 7-12 20.1-22.1 14.8-16.8 9.5-11.5 70 1.5 2.25 3 129-139 128-138 127-137 334-354 309-329 284-304 9-14 10-15 10-15 16-21 13-18 10-15 90 1.5 2.25 3 135-145 134-144 132-142 470-490 446-466 422-442 7-12 7-12 8-13 110 1.5 2.25 3 138-148 138-148 137-147 548-568 526-546 505-525 6-11 6-11 6-11 Superheat Full Load Heating - without HWG active Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 61-71 64-74 68-78 290-310 293-313 296-316 9-14 9-14 10-15 5-10 5-10 5-10 7.7-9.7 5.7-7.7 3.7-5.7 18-23 18-23 18-23 19-24 19-24 19-24 88-98 94-104 100-110 319-339 324-344 330-350 11-16 11-16 12-17 6-11 6-11 6-11 10.3-12.3 7.8-9.8 5.3-7.3 24-29 25-30 25-30 19.6-21.6 14.4-16.4 9.3-11.3 18-23 18-23 18-23 117-127 125-135 133-143 349-369 357-377 365-385 13-18 14-19 15-20 5-10 5-10 4-11 13.4-15.4 10.2-12.2 6.9-8.9 29-34 30-35 31-36 20-25 17-22 15-20 18.9-20.9 13.8-15.8 8.8-10.8 16-21 16-21 16-21 150-160 158-168 166-176 384-404 391-411 399-419 15-20 16-21 17-22 3-8 2-7 2-7 16.6-18.6 12.6-14.6 8.5-10.5 35-40 36-41 37-42 22-27 19-24 17-22 18.6-20.6 13.6-15.6 8.6-10.6 15-20 15-20 15-20 Subcooling Water Temp Drop °F Air Temp Drop °F DB *Based on 15% Methanol antifreeze solution 060 Full Load Cooling - without HWG active Entering Water Temp °F Water Flow GPM/ton Suction Pressure PSIG Discharge Pressure PSIG 30* 1.5 2.25 3 50 1.5 2.25 3 120-130 120-130 118-128 225-245 222-242 220-240 9-14 9-14 9-14 13-18 10-15 9-14 21.8-23.8 14.7-16.7 8.7-10.7 70 1.5 2.25 3 124-134 124-134 123-133 300-320 278-298 256-276 8-13 8-13 8-13 14-19 11-16 9-14 90 1.5 2.25 3 130-140 129-139 129-139 420-440 400-420 390-410 7-12 7-12 7-12 110 1.5 2.25 3 133-143 132-142 132-142 495-515 475-495 454-474 6-11 6-11 6-11 Superheat Full Load Heating - without HWG active Suction Pressure PSIG Discharge Pressure PSIG Superheat Subcooling Water Temp Drop °F Air Temp Rise °F DB 64-74 68-78 71-81 309-329 313-333 317-337 7-12 7-12 8-13 10-15 10-15 10-15 8.4-10.4 6.0-8.0 3.6-5.6 19-24 20-25 20-25 20-25 20-25 20-25 94-104 100-110 105-115 343-363 350-270 356-376 9-14 10-15 10-15 12-18 11-16 10-15 11.3-13.3 8.2-10.2 5.0-8.0 25-30 26-31 26-31 19.9-21.9 14.1-16.1 8.3-10.3 19-24 19-24 19-24 122-132 130-140 137-147 377-397 386-406 394-414 11-16 12-17 13-18 9-14 8-13 7-12 14.2-16.2 10.3-12.3 6.5-8.5 31-36 31-36 33-38 16-21 12-17 9-14 19.0-21.0 13.4-15.4 7.9-9.9 17-22 17-22 17-22 155-165 165-175 175-185 412-432 423-443 423-443 14-19 15-20 16-21 6-11 5-10 4-9 17.2-19.2 12.6-14.6 7.9-9.9 36-41 37-42 39-44 16-21 13-18 9-14 18.5-20.5 13.1-15.1 7.6-9.6 16-21 16-21 16-21 Subcooling Water Temp Drop °F Air Temp Drop °F DB *Based on 15% Methanol antifreeze solution c l i m a t e m a s t e r. c o m 43 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14a: Performance Data — Tranquility® 22 Model 024 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 120 1.7 1.7 2.2 2.2 2.2 2.2 2.2 2.2 3.0 3.0 3.3 3.3 3.3 3.3 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 WPD PSI FT 0.7 0.7 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0.8 1.0 1.0 1.0 1.0 0.6 0.6 1.6 1.6 2.8 2.8 0.5 0.5 1.4 1.4 2.5 2.5 0.5 0.5 1.2 1.2 2.2 2.2 0.5 0.5 1.2 1.2 2.1 2.1 0.5 0.5 1.2 1.2 2.0 2.0 0.5 0.5 1.2 1.2 2.0 2.0 0.5 0.5 1.1 1.1 1.9 1.9 0.3 0.3 1.0 1.0 1.8 1.8 1.5 1.5 1.4 1.4 1.4 1.4 1.4 1.4 1.9 1.9 2.4 2.4 2.4 2.4 1.4 1.4 3.7 3.7 6.4 6.4 1.2 1.2 3.2 3.2 5.7 5.7 1.1 1.1 2.9 2.9 5.2 5.2 1.1 1.1 2.7 2.7 4.9 4.9 1.1 1.1 2.7 2.7 4.7 4.7 1.1 1.1 2.7 2.7 4.6 4.6 1.0 1.0 2.5 2.5 4.4 4.4 0.8 0.8 2.3 2.3 4.2 4.2 Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 28.6 29.3 28.6 29.3 28.6 29.3 28.6 29.3 28.4 29.1 28.6 29.3 28.6 29.3 27.4 28.1 28.1 28.8 28.5 29.2 26.4 27.0 27.1 27.8 27.5 28.2 25.2 25.8 26.0 26.7 26.4 27.1 23.9 24.5 24.8 25.4 25.3 25.9 22.4 24.0 23.4 24.0 23.9 24.5 20.5 21.0 21.8 22.3 22.4 22.9 18.3 18.8 19.8 20.3 20.5 21.0 15.8 16.2 17.5 17.9 18.3 18.7 17.6 19.2 17.6 19.2 17.6 19.2 17.6 19.2 17.5 19.1 17.6 19.2 17.6 19.2 17.2 18.7 17.5 19.0 17.6 19.1 16.7 18.2 17.0 18.5 17.2 18.7 16.2 17.7 16.6 18.0 16.7 18.2 15.8 17.1 16.1 17.5 16.3 17.7 15.2 17.0 15.6 17.0 15.8 17.2 14.7 16.0 15.1 16.4 15.2 16.6 14.0 15.2 14.4 15.7 14.7 16.0 13.0 14.1 13.7 14.9 13.9 15.2 1.11 1.18 1.11 1.18 1.11 1.18 1.11 1.18 1.13 1.20 1.11 1.18 1.11 1.18 1.24 1.32 1.15 1.23 1.12 1.19 1.36 1.45 1.27 1.35 1.23 1.31 1.52 1.62 1.41 1.50 1.35 1.44 1.72 1.83 1.58 1.68 1.51 1.61 1.99 1.92 1.80 1.92 1.72 1.83 2.34 2.49 2.09 2.23 1.99 2.12 2.79 2.97 2.49 2.65 2.35 2.50 3.36 3.58 2.98 3.17 2.81 2.99 32.4 33.3 32.4 33.3 32.4 33.3 32.4 33.3 32.2 33.2 32.4 33.3 32.4 33.3 31.6 32.6 32.1 33.0 32.3 33.2 31.0 32.0 31.4 32.4 31.7 32.6 30.4 31.4 30.8 31.8 31.0 32.0 29.8 30.7 30.2 31.2 30.4 31.4 29.1 30.6 29.6 30.6 29.8 30.8 28.5 29.5 28.9 29.9 29.2 30.1 27.9 28.9 28.3 29.3 28.5 29.5 27.2 28.4 27.6 28.7 27.8 28.9 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 61.5 62.1 60.0 60.0 60.0 60.0 71.1 71.7 64.2 64.7 60.8 61.1 80.7 81.3 74.0 74.4 70.6 70.9 90.3 90.9 83.7 84.1 80.3 80.7 99.8 100.5 93.4 93.8 90.1 90.5 109.4 110.1 103.1 103.6 99.9 100.3 119.0 119.7 112.9 113.3 109.7 110.0 128.6 129.3 122.6 123.0 119.5 119.8 138.2 138.9 132.3 132.8 129.3 129.6 25.8 24.8 25.8 24.8 25.8 24.8 25.8 24.8 25.2 24.2 25.8 24.8 25.8 24.8 22.1 21.3 24.3 23.4 25.5 24.5 19.4 18.6 21.4 20.6 22.3 21.5 16.6 15.9 18.5 17.8 19.5 18.8 13.9 13.4 15.7 15.1 16.7 16.1 11.2 12.5 13.0 12.5 13.9 13.4 8.8 8.4 10.4 10.0 11.2 10.8 6.6 6.3 8.0 7.7 8.7 8.4 4.7 4.5 5.9 5.6 6.5 6.3 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. 44 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.4 1.4 1.3 1.3 1.3 1.3 1.7 1.8 1.5 1.5 1.3 1.3 2.3 2.4 1.9 2.0 1.7 1.8 3.0 3.1 2.5 2.6 2.3 2.4 3.9 4.0 3.3 3.4 3.0 3.1 4.8 4.3 4.2 4.3 3.8 3.9 5.9 6.1 5.1 5.3 4.8 5.0 7.2 7.4 6.3 6.5 5.9 6.1 8.5 8.8 7.7 7.9 7.2 7.4 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 5.2 5.2 2.6 2.6 2.6 2.6 2.6 2.6 1.7 1.7 1.7 1.7 1.7 1.7 1.3 1.3 1.3 1.3 1.3 1.3 1.0 1.0 1.0 1.0 1.0 1.0 WPD PSI FT 4.8 4.8 1.2 1.2 2.4 2.4 3.9 3.9 0.8 0.8 1.9 1.9 3.3 3.3 0.6 0.6 1.6 1.6 2.8 2.8 0.5 0.5 1.4 1.4 2.5 2.5 0.5 0.5 1.2 1.2 2.2 2.2 0.5 0.5 1.2 1.2 1.6 1.6 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 11.1 11.1 2.7 2.7 5.6 5.6 9.1 9.1 1.9 1.9 4.5 4.5 7.6 7.6 1.4 1.4 3.7 3.7 6.5 6.5 1.2 1.2 3.2 3.2 5.7 5.7 1.1 1.1 2.9 2.9 5.2 5.2 1.1 1.1 2.7 2.7 3.7 3.7 0.8 0.8 0.8 0.8 0.8 0.8 0.5 0.5 0.5 0.5 0.5 0.5 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 CFM HC kW COP HE 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 600 750 15.4 15.7 17.1 17.4 17.9 18.2 18.4 18.7 20.0 20.3 21.0 21.4 21.6 22.0 23.0 23.4 24.2 24.6 24.9 25.3 25.9 26.4 27.3 27.7 28.0 28.5 28.6 29.1 29.9 30.5 30.6 31.1 30.9 31.5 32.0 32.5 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 32.2 32.8 1.55 1.49 1.59 1.53 1.62 1.56 1.63 1.57 1.67 1.61 1.70 1.63 1.72 1.65 1.75 1.68 1.78 1.71 1.80 1.73 1.82 1.75 1.86 1.79 1.88 1.81 1.90 1.83 1.96 1.88 1.98 1.90 1.99 1.91 2.05 1.97 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.06 1.98 2.9 3.1 3.2 3.3 3.2 3.4 3.3 3.5 3.5 3.7 3.6 3.8 3.7 3.9 3.9 4.1 4.0 4.2 4.1 4.3 4.2 4.4 4.3 4.5 4.4 4.6 4.4 4.7 4.5 4.7 4.5 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 4.6 4.8 10.2 10.6 11.7 12.2 12.4 12.9 12.8 13.3 14.3 14.8 15.2 15.8 15.8 16.4 17.0 17.6 18.2 18.8 18.8 19.4 19.7 20.4 20.9 21.6 21.6 22.3 22.2 22.9 23.3 24.1 23.8 24.6 24.2 25.0 25.0 25.8 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 25.2 26.0 LAT 93.8 89.4 96.4 91.5 97.7 92.5 98.4 93.1 100.8 95.1 102.5 96.4 103.3 97.1 105.5 98.9 107.4 100.4 108.4 101.3 110.0 102.6 112.1 104.2 113.2 105.1 114.2 106.0 116.2 107.6 117.2 108.4 117.8 108.9 119.3 110.1 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 119.7 110.4 LWT HWC 16.6 16.5 22.2 21.9 24.5 24.3 25.7 25.6 30.5 30.1 33.2 33.0 34.7 34.5 38.7 38.2 41.9 41.6 43.7 43.5 46.9 46.4 50.7 50.4 52.8 52.6 55.2 54.7 59.7 59.3 62.1 61.8 63.9 63.4 68.9 68.5 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. Geothermal Heat Pump Systems 2.4 2.3 2.5 2.4 2.6 2.5 2.6 2.5 2.7 2.6 2.8 2.7 2.9 2.8 3.0 2.9 3.1 3.0 3.2 3.1 3.3 3.2 3.5 3.4 3.5 3.4 3.6 3.5 3.8 3.7 3.9 3.8 4.0 3.9 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 4.3 4.2 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14b: Performance Data — Tranquility® 22 Model 030 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 120 WPD Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 3.4 3.4 3.2 3.2 3.2 3.2 3.2 3.2 4.0 4.0 4.2 4.2 4.2 4.2 2.8 2.8 5.1 5.1 8.1 8.1 2.7 2.7 4.6 4.6 7.6 7.6 2.5 2.5 4.5 4.5 7.2 7.2 2.5 2.5 4.4 4.4 7.0 7.0 2.5 2.5 4.3 4.3 6.8 6.8 2.3 2.3 4.1 4.1 6.5 6.5 2.2 2.2 3.9 3.9 6.2 6.2 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 33.8 34.7 33.8 34.7 33.8 34.7 33.8 34.7 33.7 34.5 33.8 34.7 33.8 34.7 32.7 33.5 33.4 34.2 33.8 34.6 31.4 32.1 32.3 33.1 32.7 33.5 29.9 30.7 30.9 31.7 31.4 32.2 28.3 29.0 29.4 30.1 29.9 30.7 26.7 28.4 27.8 28.4 28.3 29.0 25.0 25.6 26.0 26.7 26.6 27.2 23.2 23.8 24.3 24.9 24.8 25.5 19.8 21.5 19.8 21.5 19.8 21.5 19.8 21.5 19.7 21.5 19.8 21.5 19.8 21.5 19.3 21.0 19.6 21.4 19.8 21.5 18.9 20.5 19.2 20.9 19.4 21.1 18.3 19.9 18.7 20.3 18.9 20.5 17.7 19.2 18.1 19.7 18.3 19.9 17.0 19.0 17.4 19.0 17.6 19.2 16.2 17.7 16.7 18.2 16.9 18.4 15.5 16.9 16.0 17.4 16.2 17.6 1.4 1.5 1.4 1.5 1.4 1.5 1.4 1.5 1.4 1.5 1.4 1.5 1.4 1.5 1.6 1.7 1.5 1.6 1.4 1.5 1.7 1.8 1.6 1.7 1.6 1.7 1.9 2.0 1.8 1.9 1.7 1.8 2.1 2.2 2.0 2.1 1.9 2.0 2.3 2.3 2.2 2.3 2.1 2.2 2.6 2.8 2.4 2.6 2.3 2.5 2.9 3.1 2.7 2.9 2.6 2.8 23.9 23.0 23.9 23.0 23.9 23.0 23.9 23.0 23.5 22.6 23.9 23.0 23.9 23.0 20.8 20.0 22.7 21.8 23.7 22.8 18.2 17.5 20.0 19.2 20.9 20.1 15.7 15.1 17.4 16.7 18.2 17.6 13.5 13.0 14.9 14.4 15.7 15.1 11.4 12.2 12.7 12.2 13.4 12.9 9.6 9.2 10.7 10.3 11.3 10.9 8.0 7.7 8.9 8.6 9.5 9.1 38.7 39.8 38.7 39.8 38.7 39.8 38.7 39.8 38.6 39.7 38.7 39.8 38.7 39.8 38.0 39.2 38.4 39.6 38.6 39.8 37.3 38.4 37.8 38.9 38.0 39.2 36.4 37.6 37.0 38.1 37.3 38.4 35.5 36.7 36.1 37.3 36.4 37.6 34.6 36.4 35.2 36.4 35.5 36.7 33.8 35.0 34.3 35.5 34.6 35.8 33.2 34.4 33.6 34.8 33.8 35.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.6 61.2 60.0 60.0 60.0 60.0 70.3 70.9 63.7 64.1 60.3 60.6 79.9 80.5 73.4 73.8 70.1 70.5 89.4 90.0 83.2 83.6 79.9 80.2 98.9 99.6 92.8 93.2 89.7 90.0 108.5 109.1 102.5 102.9 99.5 99.8 118.0 118.7 112.2 112.6 109.2 109.5 127.7 128.3 121.9 122.4 119.0 119.3 1.6 1.7 1.6 1.7 1.6 1.7 1.6 1.7 1.6 1.7 1.6 1.7 1.6 1.7 2.2 2.2 1.8 1.8 1.6 1.7 2.8 2.9 2.3 2.4 2.1 2.2 3.5 3.7 3.0 3.1 2.8 2.9 4.4 4.6 3.8 3.9 3.5 3.7 5.4 4.9 4.7 4.9 4.4 4.6 6.5 6.7 5.8 6.0 5.4 5.6 7.7 8.0 7.0 7.2 6.6 6.8 3.7 3.7 6.0 6.0 720 900 720 900 22.6 23.1 23.1 23.7 15.2 16.5 15.4 16.8 3.0 3.2 2.9 3.1 7.4 7.1 7.9 7.6 33.0 34.2 33.1 34.4 131.7 132.2 128.8 129.2 8.3 8.5 7.8 8.1 PSI FT 2.0 2.0 2.7 2.7 2.7 2.7 2.7 2.7 3.8 3.8 4.0 4.0 4.0 4.0 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 1.5 1.5 1.4 1.4 1.4 1.4 1.4 1.4 1.7 1.7 1.8 1.8 1.8 1.8 1.2 1.2 2.2 2.2 3.5 3.5 1.2 1.2 2.0 2.0 3.3 3.3 1.1 1.1 1.9 1.9 3.1 3.1 1.1 1.1 1.9 1.9 3.0 3.0 1.1 1.1 1.9 1.9 2.9 2.9 1.0 1.0 1.8 1.8 2.8 2.8 0.9 0.9 1.7 1.7 2.7 2.7 5.6 5.6 7.5 7.5 1.6 1.6 2.6 2.6 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 6.6 6.6 3.3 3.3 3.3 3.3 3.3 3.3 2.2 2.2 2.2 2.2 2.2 2.2 1.6 1.6 1.6 1.6 1.6 1.6 1.3 1.3 1.3 1.3 1.3 1.3 WPD PSI FT 5.7 5.7 2.3 2.3 3.5 3.5 5.1 5.1 1.7 1.7 2.9 2.9 4.3 4.3 1.2 1.2 2.2 2.2 3.5 3.5 1.2 1.2 2.0 2.0 3.3 3.3 1.1 1.1 1.9 1.9 3.1 3.1 1.1 1.1 1.9 1.9 2.4 2.4 0.9 0.9 0.9 0.9 0.9 0.9 0.5 0.5 0.5 0.5 0.5 0.5 0.3 0.3 0.3 0.3 0.3 0.3 0.1 0.1 0.1 0.1 0.1 0.1 13.3 13.3 5.2 5.2 8.1 8.1 11.8 11.8 4.0 4.0 6.6 6.6 10.0 10.0 2.8 2.8 5.1 5.1 8.1 8.1 2.7 2.7 4.6 4.6 7.6 7.6 2.5 2.5 4.5 4.5 7.2 7.2 2.5 2.5 4.4 4.4 5.5 5.5 2.0 2.0 2.0 2.0 2.0 2.0 1.2 1.2 1.2 1.2 1.2 1.2 0.8 0.8 0.8 0.8 0.8 0.8 0.2 0.2 0.2 0.2 0.2 0.2 CFM HC kW COP HE LAT LWT HWC 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 720 900 21.4 21.8 23.1 23.5 24.0 24.5 24.6 25.0 26.1 26.6 27.2 27.7 27.8 28.3 29.2 29.7 30.5 31.0 31.2 31.7 32.3 32.9 33.8 34.4 34.6 35.2 35.4 36.0 37.0 37.7 37.9 38.6 38.5 39.2 40.3 40.9 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 40.8 41.5 2.0 1.9 2.1 2.0 2.1 2.0 2.1 2.0 2.2 2.1 2.2 2.1 2.2 2.1 2.3 2.2 2.3 2.2 2.3 2.2 2.4 2.3 2.4 2.3 2.4 2.3 2.5 2.4 2.5 2.4 2.5 2.4 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 2.6 2.5 98 92 100 94 101 95 102 96 104 97 105 98 106 99 108 101 109 102 110 103 112 104 113 105 114 106 116 107 118 109 119 110 120 110 122 112 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 122 113 16.1 16.0 21.4 21.1 24.0 23.7 25.4 25.2 30.0 29.6 33.0 32.7 34.6 34.4 38.5 38.1 42.0 41.7 43.8 43.6 47.1 46.6 50.9 50.6 53.0 52.8 55.6 55.1 59.9 59.5 62.2 61.9 64.1 63.6 68.9 68.5 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 3.1 3.3 3.3 3.5 3.4 3.6 3.4 3.6 3.5 3.7 3.6 3.8 3.7 3.9 3.8 4.0 3.9 4.1 3.9 4.2 4.0 4.2 4.1 4.4 4.2 4.4 4.2 4.5 4.3 4.6 4.4 4.6 4.4 4.7 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 14.5 15.2 16.1 16.7 16.9 17.6 17.3 18.0 18.7 19.5 19.7 20.5 20.3 21.0 21.5 22.3 22.6 23.5 23.3 24.1 24.3 25.1 25.6 26.5 26.3 27.2 27.0 28.0 28.5 29.4 29.2 30.2 29.8 30.8 31.3 32.4 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 31.8 32.8 2.8 2.7 2.9 2.8 3.0 2.9 3.0 2.9 3.1 3.0 3.2 3.1 3.3 3.2 3.4 3.3 3.6 3.5 3.6 3.5 3.8 3.7 4.0 3.9 4.1 4.0 4.2 4.1 4.5 4.4 4.6 4.5 4.7 4.6 5.1 4.9 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 5.3 5.1 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. c l i m a t e m a s t e r. c o m 45 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14c: Performance Data — Tranquility® 22 Model 036 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 120 2.3 2.3 3.1 3.1 3.1 3.1 3.1 3.1 4.5 4.5 4.7 4.7 4.7 4.7 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 WPD PSI FT 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.5 0.5 0.6 0.6 0.6 0.6 0.2 0.2 1.5 1.5 2.9 2.9 0.1 0.1 1.2 1.2 2.6 2.6 0.1 0.1 1.1 1.1 2.4 2.4 0.1 0.1 1.1 1.1 2.3 2.3 0.2 0.2 1.1 1.1 2.3 2.3 0.2 0.2 1.1 1.1 2.3 2.3 0.2 0.2 1.1 1.1 2.3 2.3 0.1 0.1 1.0 1.0 2.2 2.2 0.4 0.4 0.3 0.3 0.3 0.3 0.3 0.3 1.1 1.1 1.3 1.3 1.3 1.3 0.5 0.5 3.3 3.3 6.7 6.7 0.3 0.3 2.8 2.8 5.9 5.9 0.3 0.3 2.6 2.6 5.5 5.5 0.3 0.3 2.5 2.5 5.3 5.3 0.4 0.4 2.5 2.5 5.2 5.2 0.5 0.5 2.5 2.5 5.2 5.2 0.4 0.4 2.5 2.5 5.2 5.2 0.2 0.2 2.3 2.3 5.1 5.1 Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 39.8 40.8 39.8 40.8 39.8 40.8 39.8 40.8 39.8 40.8 39.8 40.8 39.8 40.8 39.0 40.0 39.6 40.6 39.8 40.8 37.8 38.8 38.7 39.6 39.0 40.0 36.4 37.3 37.4 38.3 37.9 38.8 34.7 35.5 35.8 36.7 36.4 37.3 32.7 34.8 34.0 34.8 34.6 35.5 30.6 31.4 32.0 32.8 32.6 33.4 28.4 29.1 29.8 30.5 30.5 31.2 26.1 26.8 27.5 28.2 28.2 28.9 25.3 27.6 25.3 27.6 25.3 27.6 25.3 27.6 25.3 27.6 25.3 27.6 25.3 27.6 25.2 27.4 25.3 27.5 25.3 27.6 24.7 26.9 25.0 27.2 25.2 27.4 24.1 26.3 24.6 26.7 24.7 26.9 23.4 25.5 23.9 26.0 24.1 26.3 22.6 25.2 23.2 25.2 23.4 25.5 21.8 23.7 22.3 24.3 22.6 24.6 20.9 22.8 21.5 23.4 21.7 23.7 20.0 21.8 20.6 22.4 20.9 22.7 1.59 1.69 1.59 1.69 1.59 1.69 1.59 1.69 1.60 1.70 1.59 1.69 1.59 1.69 1.73 1.84 1.63 1.74 1.60 1.70 1.90 2.02 1.78 1.90 1.73 1.84 2.10 2.24 1.96 2.09 1.90 2.02 2.36 2.51 2.19 2.33 2.10 2.24 2.65 2.61 2.45 2.61 2.36 2.51 2.99 3.18 2.76 2.94 2.66 2.83 3.38 3.60 3.13 3.33 3.01 3.21 3.84 4.09 3.56 3.79 3.42 3.64 45.2 46.6 45.2 46.6 45.2 46.6 45.2 46.6 45.2 46.6 45.2 46.6 45.2 46.6 44.9 46.2 45.2 46.5 45.3 46.6 44.3 45.7 44.8 46.1 44.9 46.3 43.6 44.9 44.1 45.4 44.3 45.7 42.7 44.1 43.3 44.6 43.5 44.9 41.8 43.7 42.4 43.7 42.7 44.0 40.8 42.2 41.4 42.8 41.7 43.1 40.0 41.4 40.5 41.9 40.8 42.2 39.2 40.7 39.7 41.1 39.9 41.4 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.1 60.7 60.0 60.0 60.0 60.0 70.0 70.6 63.4 63.8 60.1 60.4 79.7 80.3 73.3 73.7 70.0 70.3 89.4 90.0 83.1 83.5 79.9 80.2 99.0 99.6 92.8 93.2 89.7 90.0 108.6 109.2 102.6 103.0 99.5 99.8 118.1 118.8 112.3 112.7 109.3 109.6 127.8 128.4 122.0 122.4 119.1 119.4 137.4 138.1 131.8 132.2 128.9 129.2 25.1 24.2 25.1 24.2 25.1 24.2 25.1 24.2 24.9 24.0 25.1 24.2 25.1 24.2 22.6 21.7 24.2 23.3 24.9 24.0 19.9 19.2 21.7 20.9 22.6 21.7 17.3 16.6 19.1 18.3 20.0 19.2 14.7 14.1 16.4 15.7 17.3 16.6 12.4 13.3 13.9 13.3 14.7 14.1 10.3 9.9 11.6 11.1 12.3 11.8 8.4 8.1 9.5 9.2 10.1 9.7 6.8 6.5 7.7 7.4 8.3 7.9 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. 46 1.7 1.8 1.7 1.8 1.7 1.8 1.7 1.8 1.7 1.8 1.7 1.8 1.7 1.8 2.3 2.4 1.9 2.0 1.7 1.8 3.1 3.2 2.5 2.6 2.3 2.4 4.1 4.2 3.4 3.5 3.0 3.1 5.2 5.4 4.5 4.6 4.1 4.2 6.6 5.9 5.7 5.9 5.2 5.4 8.2 8.5 7.2 7.4 6.7 6.9 10.1 10.4 8.9 9.2 8.3 8.6 12.2 12.6 10.9 11.2 10.3 10.6 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 7.6 7.6 3.8 3.8 3.8 3.8 3.8 3.8 2.5 2.5 2.5 2.5 2.5 2.5 1.9 1.9 1.9 1.9 1.9 1.9 1.5 1.5 1.5 1.5 1.5 1.5 WPD PSI FT 4.9 4.9 0.8 0.8 2.3 2.3 4.0 4.0 0.5 0.5 1.8 1.8 3.4 3.4 0.2 0.2 1.5 1.5 2.9 2.9 0.1 0.1 1.2 1.2 2.6 2.6 0.1 0.1 1.1 1.1 2.4 2.4 0.1 0.1 1.1 1.1 1.5 1.5 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 11.4 11.4 1.9 1.9 5.4 5.4 9.3 9.3 1.1 1.1 4.2 4.2 7.8 7.8 0.5 0.5 3.4 3.4 6.7 6.7 0.3 0.3 2.9 2.9 5.9 5.9 0.3 0.3 2.6 2.6 5.5 5.5 0.3 0.3 2.5 2.5 3.5 3.5 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 CFM HC kW COP HE 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 920 1150 24.7 25.1 26.8 27.3 27.9 28.4 28.5 29.0 30.6 31.1 32.0 32.6 32.8 33.4 34.6 35.2 36.3 37.0 37.3 37.9 38.7 39.3 40.5 41.2 41.5 42.2 42.5 43.2 44.3 45.1 45.2 46.0 45.8 46.6 47.4 48.2 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 47.7 48.5 2.40 2.31 2.45 2.36 2.48 2.38 2.50 2.40 2.54 2.44 2.57 2.47 2.59 2.49 2.63 2.53 2.66 2.56 2.69 2.59 2.72 2.62 2.79 2.68 2.82 2.71 2.86 2.75 2.94 2.83 2.98 2.87 3.03 2.91 3.14 3.02 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.17 3.05 3.0 3.2 3.2 3.4 3.3 3.5 3.4 3.5 3.5 3.7 3.7 3.9 3.7 3.9 3.9 4.1 4.0 4.2 4.1 4.3 4.2 4.4 4.3 4.5 4.3 4.6 4.4 4.6 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 4.4 4.7 16.5 17.2 18.4 19.2 19.5 20.3 20.0 20.8 22.0 22.8 23.3 24.2 24.0 24.9 25.7 26.6 27.2 28.2 28.1 29.1 29.4 30.4 31.0 32.1 31.9 33.0 32.7 33.8 34.3 35.4 35.0 36.2 35.5 36.7 36.7 37.9 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 36.9 38.1 LAT 94.8 90.2 97.0 92.0 98.1 92.9 98.7 93.4 100.8 95.1 102.2 96.2 103.0 96.9 104.9 98.4 106.6 99.8 107.5 100.5 108.9 101.7 110.8 103.2 111.8 104.0 112.8 104.8 114.6 106.3 115.5 107.0 116.1 107.5 117.7 108.8 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 118.0 109.1 LWT HWC 16.3 16.2 21.8 21.5 24.2 24.0 25.6 25.4 30.2 29.9 33.1 32.8 34.7 34.5 38.6 38.2 41.9 41.6 43.8 43.5 46.9 46.5 50.8 50.5 52.9 52.7 55.5 55.0 59.8 59.5 62.2 62.0 64.2 63.7 69.2 68.8 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. Geothermal Heat Pump Systems 3.4 3.3 3.5 3.4 3.6 3.5 3.6 3.5 3.8 3.7 3.9 3.8 4.0 3.9 4.2 4.1 4.3 4.2 4.4 4.3 4.6 4.5 4.9 4.8 5.0 4.9 5.2 5.0 5.6 5.4 5.7 5.5 5.9 5.7 6.3 6.1 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 6.4 6.2 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14d: Performance Data — Tranquility® 22 Model 042 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 120 WPD Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 3.4 3.4 3.6 3.6 3.6 3.6 3.6 3.6 4.1 4.1 5.1 5.1 5.1 5.1 4.1 4.1 7.9 7.9 12.5 12.5 3.9 3.9 7.5 7.5 11.9 11.9 3.6 3.6 7.1 7.1 11.3 11.3 3.5 3.5 6.9 6.9 11.0 11.0 3.4 3.4 6.6 6.6 10.7 10.7 3.3 3.3 6.4 6.4 10.4 10.4 3.2 3.2 6.2 6.2 10.1 10.1 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 1040 1300 48.2 49.4 48.2 49.4 48.2 49.4 48.2 49.4 48.0 49.2 48.2 49.4 48.2 49.4 46.6 47.8 47.7 48.8 48.1 49.3 45.0 46.1 46.1 47.3 46.7 47.9 43.1 44.1 44.4 45.5 45.0 46.1 41.0 42.0 42.4 43.5 43.1 44.2 38.7 41.2 40.2 41.2 41.0 42.0 36.2 37.1 37.8 38.8 38.6 39.6 33.6 34.5 35.3 36.2 36.1 37.0 33.2 36.1 33.2 36.1 33.2 36.1 33.2 36.1 33.0 35.9 33.2 36.1 33.2 36.1 32.2 35.0 32.8 35.7 33.1 36.0 31.3 34.1 31.9 34.8 32.3 35.1 30.4 33.1 31.0 33.8 31.4 34.1 29.5 32.2 30.1 32.8 30.4 33.1 28.7 31.8 29.3 31.8 29.5 32.2 27.9 30.4 28.4 31.0 28.7 31.2 27.2 29.6 27.7 30.1 27.9 30.4 2.0 2.1 2.0 2.1 2.0 2.1 2.0 2.1 2.0 2.1 2.0 2.1 2.0 2.1 2.2 2.3 2.0 2.2 2.0 2.1 2.4 2.5 2.2 2.4 2.2 2.3 2.6 2.8 2.5 2.6 2.4 2.5 2.9 3.1 2.7 2.9 2.6 2.8 3.2 3.2 3.0 3.2 2.9 3.1 3.6 3.8 3.4 3.6 3.2 3.4 4.0 4.3 3.7 4.0 3.6 3.8 24.6 23.6 24.6 23.6 24.6 23.6 24.6 23.6 24.1 23.2 24.6 23.6 24.6 23.6 21.4 20.6 23.3 22.5 24.3 23.4 18.8 18.1 20.6 19.8 21.6 20.7 16.3 15.7 18.0 17.3 18.9 18.2 14.1 13.5 15.6 15.0 16.4 15.8 12.0 12.8 13.3 12.8 14.1 13.5 10.1 9.7 11.3 10.9 11.9 11.5 8.4 8.1 9.4 9.1 10.0 9.6 54.9 56.6 54.9 56.6 54.9 56.6 54.9 56.6 54.8 56.4 54.9 56.6 54.9 56.6 54.0 55.7 54.6 56.2 54.9 56.5 53.1 54.7 53.8 55.4 54.1 55.7 52.1 53.7 52.8 54.4 53.2 54.8 50.9 52.6 51.7 53.3 52.1 53.7 49.7 52.2 50.5 52.2 50.9 52.6 48.5 50.2 49.3 51.0 49.7 51.4 47.3 49.0 48.0 49.7 48.4 50.1 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.9 61.5 60.0 60.0 60.0 60.0 70.6 71.2 63.9 64.3 60.5 60.8 80.2 80.9 73.7 74.1 70.3 70.6 89.8 90.5 83.4 83.8 80.1 80.4 99.4 100.0 93.1 93.5 89.9 90.2 108.9 109.6 102.8 103.3 99.7 100.0 118.5 119.1 112.5 112.9 109.5 109.8 128.0 128.7 122.2 122.6 119.2 119.5 1.6 1.7 1.6 1.7 1.6 1.7 1.6 1.7 1.7 1.8 1.6 1.7 1.6 1.7 2.2 2.3 1.8 1.9 1.7 1.7 2.9 3.0 2.4 2.5 2.2 2.3 3.7 3.8 3.1 3.2 2.9 3.0 4.6 4.7 4.0 4.1 3.7 3.8 5.6 5.1 4.9 5.1 4.6 4.7 6.7 6.9 6.0 6.2 5.6 5.8 8.0 8.2 7.2 7.4 6.8 7.0 6.0 6.0 9.8 9.8 1040 1300 1040 1300 32.6 33.4 33.4 34.3 26.9 29.3 27.2 29.6 4.2 4.4 4.0 4.3 7.8 7.5 8.3 8.0 46.8 48.5 47.2 48.9 131.9 132.3 129.0 129.3 8.5 8.8 8.1 8.3 PSI FT 2.8 2.8 3.8 3.8 3.8 3.8 3.8 3.8 5.3 5.3 5.7 5.7 5.7 5.7 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.8 1.8 2.2 2.2 2.2 2.2 1.8 1.8 3.4 3.4 5.4 5.4 1.7 1.7 3.2 3.2 5.2 5.2 1.6 1.6 3.1 3.1 4.9 4.9 1.5 1.5 3.0 3.0 4.8 4.8 1.5 1.5 2.9 2.9 4.7 4.7 1.4 1.4 2.8 2.8 4.5 4.5 1.4 1.4 2.7 2.7 4.4 4.4 7.9 7.9 10.5 10.5 2.6 2.6 4.2 4.2 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. WPD PSI FT 8.4 8.4 2.7 2.7 4.8 4.8 7.4 7.4 1.8 1.8 4.1 4.1 6.4 6.4 1.8 1.8 3.4 3.4 5.4 5.4 1.7 1.7 3.2 3.2 5.2 5.2 1.6 1.6 3.1 3.1 4.9 4.9 1.5 1.5 3.0 3.0 3.7 3.7 1.2 1.2 1.2 1.2 1.2 1.2 0.8 0.8 0.8 0.8 0.8 0.8 0.6 0.6 0.6 0.6 0.6 0.6 0.3 0.3 0.3 0.3 0.3 0.3 19.4 19.4 6.2 6.2 11.1 11.1 17.0 17.0 4.1 4.1 9.5 9.5 14.7 14.7 4.1 4.1 7.9 7.9 12.5 12.5 3.9 3.9 7.5 7.5 11.9 11.9 3.6 3.6 7.1 7.1 11.3 11.3 3.5 3.5 6.9 6.9 8.5 8.5 2.8 2.8 2.8 2.8 2.8 2.8 1.8 1.8 1.8 1.8 1.8 1.8 1.3 1.3 1.3 1.3 1.3 1.3 0.8 0.8 0.8 0.8 0.8 0.8 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 9.1 9.1 4.5 4.5 4.5 4.5 4.5 4.5 3.0 3.0 3.0 3.0 3.0 3.0 2.3 2.3 2.3 2.3 2.3 2.3 1.8 1.8 1.8 1.8 1.8 1.8 CFM HC kW COP HE LAT LWT HWC 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 1,040 1,300 29.1 29.6 31.8 32.4 33.1 33.7 33.9 34.4 36.2 36.9 37.8 38.5 38.6 39.3 40.6 41.3 42.4 43.2 43.4 44.1 45.0 45.8 47.0 47.8 48.1 48.9 49.3 50.1 51.5 52.4 52.6 53.5 53.5 54.4 55.8 56.8 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 56.4 57.4 2.9 2.8 3.0 2.9 3.0 2.9 3.1 2.9 3.1 3.0 3.2 3.0 3.2 3.1 3.2 3.1 3.3 3.2 3.3 3.2 3.3 3.2 3.4 3.3 3.4 3.3 3.5 3.3 3.5 3.4 3.6 3.4 3.6 3.4 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 96 91 98 93 100 94 100 95 102 96 104 97 104 98 106 99 108 101 109 101 110 103 112 104 113 105 114 106 116 107 117 108 118 109 120 110 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 120 111 16.4 16.2 21.8 21.4 24.2 24.0 25.5 25.4 30.3 29.9 33.1 32.9 34.7 34.5 38.7 38.3 42.1 41.8 43.9 43.7 47.2 46.7 51.0 50.7 53.1 52.8 55.7 55.2 60.0 59.6 62.3 62.0 64.3 63.8 69.0 68.6 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 2.9 3.1 3.1 3.3 3.2 3.4 3.2 3.4 3.4 3.6 3.5 3.7 3.6 3.8 3.7 3.9 3.8 4.0 3.8 4.1 3.9 4.2 4.0 4.3 4.1 4.3 4.2 4.4 4.3 4.5 4.3 4.6 4.4 4.6 4.5 4.7 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 4.5 4.8 19.0 19.9 21.5 22.5 22.8 23.7 23.4 24.4 25.6 26.6 27.0 28.1 27.8 28.9 29.6 30.7 31.2 32.4 32.1 33.3 33.6 34.8 35.4 36.6 36.4 37.6 37.5 38.8 39.4 40.8 40.5 41.9 41.2 42.6 43.3 44.8 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 43.9 45.4 3.4 3.3 3.6 3.4 3.6 3.5 3.7 3.6 3.8 3.7 3.9 3.8 4.0 3.9 4.2 4.1 4.4 4.2 4.5 4.3 4.6 4.5 4.9 4.7 5.0 4.9 5.2 5.0 5.5 5.3 5.7 5.5 5.8 5.6 6.2 6.0 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 6.3 6.1 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. c l i m a t e m a s t e r. c o m 47 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14e: Performance Data — Tranquility® 22 Model 048 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 WPD Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 1200 1500 52.8 54.1 52.8 54.1 52.8 54.1 52.8 54.1 52.8 54.1 52.8 54.1 52.8 54.1 51.7 53.0 52.5 53.8 52.8 54.1 50.0 51.3 51.2 52.5 51.8 53.0 47.9 49.1 49.4 50.6 50.1 51.3 45.4 46.5 47.1 48.2 47.9 49.1 42.8 45.6 44.5 45.6 45.4 46.5 40.0 41.0 41.8 42.8 42.7 43.7 37.4 38.3 39.0 40.0 39.9 40.9 33.2 36.1 33.2 36.1 33.2 36.1 33.2 36.1 33.1 36.1 33.2 36.1 33.2 36.1 32.7 35.6 33.0 36.0 33.2 36.1 32.1 34.9 32.6 35.4 32.7 35.6 31.3 34.0 31.8 34.7 32.1 34.9 30.3 33.0 31.0 33.7 31.3 34.0 29.3 32.6 30.0 32.6 30.3 33.0 28.2 30.7 28.9 31.5 29.3 31.8 27.2 29.5 27.8 30.3 28.2 30.6 2.2 2.4 2.2 2.4 2.2 2.4 2.2 2.4 2.2 2.4 2.2 2.4 2.2 2.4 2.4 2.6 2.3 2.4 2.2 2.4 2.7 2.9 2.5 2.7 2.4 2.6 3.0 3.2 2.8 3.0 2.7 2.9 3.4 3.6 3.1 3.3 3.0 3.2 3.9 3.8 3.6 3.8 3.4 3.6 4.4 4.7 4.0 4.3 3.9 4.1 5.0 5.3 4.6 4.9 4.4 4.7 23.9 23.0 23.9 23.0 23.9 23.0 23.9 23.0 23.7 22.8 23.9 23.0 23.9 23.0 21.4 20.5 23.0 22.2 23.8 22.9 18.6 17.9 20.5 19.7 21.4 20.6 15.9 15.3 17.7 17.1 18.7 18.0 13.3 12.8 15.0 14.4 15.9 15.3 11.1 12.0 12.5 12.0 13.3 12.8 9.1 8.8 10.3 9.9 11.0 10.6 7.5 7.2 8.5 8.2 9.0 8.7 60.4 62.2 60.4 62.2 60.4 62.2 60.4 62.2 60.4 62.2 60.4 62.2 60.4 62.2 60.0 61.8 60.3 62.1 60.4 62.2 59.2 61.0 59.8 61.6 60.0 61.8 58.1 60.0 58.9 60.7 59.2 61.0 57.0 58.9 57.8 59.6 58.1 60.0 55.9 58.5 56.6 58.5 57.0 58.9 55.0 57.0 55.6 57.5 55.9 57.8 54.4 56.5 54.7 56.7 55.0 56.9 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.1 60.7 60.0 60.0 60.0 60.0 70.0 70.6 63.4 63.8 60.1 60.4 79.7 80.3 73.3 73.7 70.0 70.3 89.4 90.0 83.1 83.5 79.9 80.2 99.0 99.6 92.8 93.2 89.7 90.0 108.6 109.3 102.6 103.0 99.5 99.8 118.3 119.0 112.3 112.8 109.3 109.6 128.1 128.8 122.2 122.6 119.2 119.5 2.4 2.5 2.4 2.5 2.4 2.5 2.4 2.5 2.5 2.5 2.4 2.5 2.4 2.5 3.1 3.2 2.6 2.7 2.4 2.5 3.9 4.0 3.3 3.4 3.0 3.1 4.8 5.0 4.2 4.3 3.8 4.0 6.0 6.2 5.2 5.4 4.8 5.0 7.3 6.6 6.4 6.6 6.0 6.2 8.9 9.2 7.9 8.1 7.4 7.6 10.6 11.0 9.5 9.8 9.0 9.2 10.0 1200 10.0 1500 37.2 38.2 27.1 29.5 5.0 5.4 7.4 7.1 54.4 129.1 56.4 129.4 10.7 11.1 PSI FT 3.1 3.1 4.1 4.1 4.1 4.1 4.1 4.1 6.0 6.0 6.2 6.2 6.2 6.2 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 1.1 1.1 1.2 1.2 1.2 1.2 1.2 1.2 1.9 1.9 2.0 2.0 2.0 2.0 1.7 1.7 3.4 3.4 5.5 5.5 1.6 1.6 3.2 3.2 5.3 5.3 1.4 1.4 3.0 3.0 4.9 4.9 1.4 1.4 2.9 2.9 4.8 4.8 1.3 1.3 2.8 2.8 4.7 4.7 1.3 1.3 2.7 2.7 4.5 4.5 1.2 1.2 2.6 2.6 4.4 4.4 2.5 2.5 2.8 2.8 2.8 2.8 2.8 2.8 4.4 4.4 4.7 4.7 4.7 4.7 4.0 4.0 7.9 7.9 12.7 12.7 3.7 3.7 7.5 7.5 12.2 12.2 3.3 3.3 6.9 6.9 11.3 11.3 3.3 3.3 6.7 6.7 11.1 11.1 3.1 3.1 6.5 6.5 10.9 10.9 3.0 3.0 6.1 6.1 10.4 10.4 2.8 2.8 5.9 5.9 10.1 10.1 12.0 12.0 4.3 4.3 120 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. 48 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 10.2 10.2 5.1 5.1 5.1 5.1 5.1 5.1 3.4 3.4 3.4 3.4 3.4 3.4 2.6 2.6 2.6 2.6 2.6 2.6 2.0 2.0 2.0 2.0 2.0 2.0 WPD PSI FT 7.7 7.7 2.0 2.0 4.0 4.0 6.5 6.5 1.9 1.9 3.8 3.8 6.0 6.0 1.7 1.7 3.4 3.4 5.5 5.5 1.6 1.6 3.2 3.2 5.3 5.3 1.4 1.4 3.0 3.0 4.9 4.9 1.4 1.4 2.9 2.9 3.6 3.6 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.4 0.4 0.4 0.4 0.4 0.4 0.2 0.2 0.2 0.2 0.2 0.2 17.8 17.8 4.6 4.6 9.2 9.2 15.1 15.1 4.4 4.4 8.7 8.7 13.9 13.9 4.0 4.0 7.9 7.9 12.7 12.7 3.7 3.7 7.5 7.5 12.2 12.2 3.3 3.3 6.9 6.9 11.3 11.3 3.3 3.3 6.7 6.7 8.3 8.3 2.5 2.5 2.5 2.5 2.5 2.5 1.4 1.4 1.4 1.4 1.4 1.4 0.9 0.9 0.9 0.9 0.9 0.9 0.4 0.4 0.4 0.4 0.4 0.4 CFM HC kW COP HE LAT LWT HWC 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 1,200 1,500 31.9 32.4 34.6 35.2 35.8 36.5 36.6 37.2 39.1 39.7 40.7 41.4 41.5 42.3 43.8 44.6 45.7 46.5 46.8 47.6 48.7 49.5 50.9 51.8 52.1 53.0 53.7 54.6 56.2 57.2 57.6 58.6 58.6 59.7 61.4 62.5 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 62.1 63.2 3.0 2.9 3.0 2.9 3.1 3.0 3.1 3.0 3.1 3.0 3.2 3.1 3.2 3.1 3.2 3.1 3.3 3.2 3.3 3.2 3.3 3.2 3.4 3.3 3.4 3.3 3.5 3.3 3.5 3.4 3.5 3.4 3.6 3.4 3.6 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 3.7 3.5 95 90 97 92 98 93 98 93 100 95 101 96 102 96 104 98 105 99 106 99 108 101 109 102 110 103 111 104 113 105 114 106 115 107 117 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 118 109 16.4 16.2 22.0 21.6 24.4 24.1 25.7 25.5 30.6 30.2 33.4 33.1 34.9 34.7 39.1 38.7 42.3 42.1 44.1 43.9 47.6 47.2 51.3 51.0 53.3 53.0 56.0 55.6 60.2 59.9 62.4 62.2 64.5 64.0 69.1 68.8 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 3.1 3.3 3.3 3.5 3.4 3.6 3.5 3.7 3.6 3.9 3.8 4.0 3.8 4.0 4.0 4.2 4.1 4.3 4.1 4.4 4.3 4.5 4.4 4.7 4.5 4.7 4.6 4.8 4.7 5.0 4.8 5.0 4.8 5.1 4.9 5.2 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 5.0 5.3 21.7 22.6 24.1 25.1 25.3 26.4 26.0 27.0 28.3 29.4 29.8 30.9 30.6 31.8 32.7 33.9 34.5 35.7 35.5 36.7 37.3 38.5 39.3 40.7 40.5 41.8 41.9 43.2 44.2 45.6 45.5 46.9 46.5 47.9 49.0 50.5 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 49.6 51.2 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. Geothermal Heat Pump Systems 3.6 3.5 3.8 3.6 3.8 3.7 3.9 3.8 4.0 3.9 4.1 4.0 4.2 4.1 4.4 4.2 4.5 4.4 4.6 4.5 4.7 4.6 4.9 4.8 5.0 4.9 5.2 5.0 5.4 5.3 5.6 5.4 5.7 5.5 6.0 5.8 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 6.1 5.9 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Table 14f: Performance Data — Tranquility® 22 Model 060 - Full Load Performance capacities shown in thousands of Btuh Antifreeze use recommended in this range. Also Clip JW3 on DXM2 board. Cooling - EAT 80/67°F EWT °F GPM 20 30 40 50 60 70 80 90 100 110 120 4.1 4.1 5.5 5.5 5.5 5.5 5.5 5.5 7.0 7.0 8.2 8.2 8.2 8.2 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 WPD PSI FT 0.5 0.5 0.9 0.9 0.9 0.9 0.9 0.9 1.6 1.6 2.3 2.3 2.3 2.3 1.4 1.4 3.5 3.5 6.2 6.2 1.3 1.3 3.3 3.3 5.9 5.9 1.2 1.2 3.2 3.2 5.6 5.6 1.2 1.2 3.1 3.1 5.4 5.4 1.2 1.2 3.0 3.0 5.3 5.3 1.1 1.1 2.9 2.9 5.2 5.2 1.0 1.0 2.8 2.8 5.1 5.1 0.9 0.9 2.7 2.7 5.0 5.0 1.1 1.1 2.2 2.2 2.2 2.2 2.2 2.2 3.6 3.6 5.2 5.2 5.2 5.2 3.2 3.2 8.1 8.1 14.3 14.3 3.0 3.0 7.6 7.6 13.5 13.5 2.8 2.8 7.3 7.3 13.0 13.0 2.8 2.8 7.1 7.1 12.5 12.5 2.7 2.7 6.9 6.9 12.3 12.3 2.6 2.6 6.8 6.8 12.1 12.1 2.4 2.4 6.6 6.6 11.9 11.9 2.0 2.0 6.3 6.3 11.6 11.6 Heating - EAT 70°F CFM TC SC kW EER HR LWT HWC GPM 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 70.3 72.0 70.3 72.0 70.3 72.0 70.3 72.0 69.6 71.4 70.3 72.0 70.3 72.0 67.8 69.5 69.2 70.9 70.0 71.7 65.9 67.5 67.4 69.0 68.1 69.8 63.7 65.2 65.3 67.0 66.1 67.8 61.1 62.6 63.0 64.6 63.9 65.5 57.9 61.8 60.3 61.8 61.4 62.9 54.2 55.5 56.9 58.3 58.2 59.7 49.7 50.9 52.9 54.2 54.4 55.8 44.3 45.4 48.0 49.2 49.8 51.0 43.4 47.3 43.4 47.3 43.4 47.3 43.4 47.3 43.2 47.0 43.4 47.3 43.4 47.3 42.5 46.3 43.0 46.8 43.3 47.1 41.8 45.5 42.3 46.1 42.6 46.4 41.0 44.6 41.6 45.3 41.9 45.6 40.1 43.6 40.8 44.4 41.1 44.7 39.0 43.3 39.8 43.3 40.2 43.7 37.6 40.9 38.6 42.0 39.1 42.5 35.9 39.0 37.1 40.4 37.7 41.0 33.5 36.5 35.2 38.3 35.9 39.1 2.71 2.89 2.71 2.89 2.71 2.89 2.71 2.89 2.80 2.98 2.71 2.89 2.71 2.89 3.06 3.26 2.86 3.05 2.76 2.94 3.34 3.56 3.13 3.33 3.02 3.22 3.65 3.89 3.41 3.63 3.30 3.51 4.03 4.29 3.75 3.99 3.62 3.85 4.48 4.41 4.14 4.41 3.99 4.25 5.02 5.35 4.62 4.92 4.44 4.73 5.67 6.04 5.21 5.55 4.99 5.31 6.44 6.86 5.91 6.29 5.65 6.02 79.5 81.9 79.5 81.9 79.5 81.9 79.5 81.9 79.2 81.5 79.5 81.9 79.5 81.9 78.3 80.6 79.0 81.3 79.4 81.7 77.3 79.6 78.0 80.4 78.4 80.8 76.1 78.5 77.0 79.3 77.4 79.7 74.8 77.2 75.8 78.2 76.3 78.7 73.2 76.8 74.4 76.8 75.0 77.4 71.3 73.8 72.7 75.1 73.4 75.8 69.0 71.5 70.7 73.1 71.4 73.9 66.3 68.8 68.2 70.7 69.1 71.6 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 62.6 63.3 60.0 60.0 60.0 60.0 72.4 73.0 65.0 65.5 61.3 61.7 82.1 82.7 74.9 75.3 71.2 71.5 91.7 92.4 84.7 85.1 81.1 81.4 101.4 102.1 94.4 94.9 90.9 91.2 110.9 111.6 104.2 104.6 100.7 101.0 120.4 121.1 113.8 114.3 110.5 110.8 129.7 130.4 123.5 123.9 120.2 120.6 139.0 139.7 133.0 133.5 129.9 130.2 25.9 24.9 25.9 24.9 25.9 24.9 25.9 24.9 24.9 23.9 25.9 24.9 25.9 24.9 22.2 21.3 24.2 23.3 25.3 24.4 19.7 19.0 21.5 20.7 22.5 21.7 17.4 16.8 19.2 18.4 20.1 19.3 15.2 14.6 16.8 16.2 17.7 17.0 12.9 14.0 14.6 14.0 15.4 14.8 10.8 10.4 12.3 11.9 13.1 12.6 8.8 8.4 10.2 9.8 10.9 10.5 6.9 6.6 8.1 7.8 8.8 8.5 Interpolation is permissible; extrapolation is not. Flow is changed to maintain minimum LWT 60° F in cooling and maximum LWT 70° F in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. 2.4 2.5 2.4 2.5 2.4 2.5 2.4 2.5 2.5 2.6 2.4 2.5 2.4 2.5 3.2 3.3 2.7 2.8 2.5 2.6 4.0 4.1 3.4 3.5 3.1 3.2 5.0 5.2 4.3 4.4 4.0 4.1 6.2 6.4 5.3 5.5 4.9 5.1 7.6 6.8 6.6 6.8 6.1 6.3 9.1 9.4 8.0 8.3 7.5 7.7 10.9 11.2 9.7 10.0 9.1 9.4 12.8 13.2 11.5 11.9 10.9 11.2 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 7.0 7.0 10.5 10.5 14.0 14.0 6.3 6.3 6.3 6.3 6.3 6.3 4.2 4.2 4.2 4.2 4.2 4.2 3.2 3.2 3.2 3.2 3.2 3.2 2.5 2.5 2.5 2.5 2.5 2.5 WPD PSI FT 7.9 7.9 1.8 1.8 4.2 4.2 7.2 7.2 1.5 1.5 3.8 3.8 6.6 6.6 1.4 1.4 3.5 3.5 6.2 6.2 1.3 1.3 3.3 3.3 5.8 5.8 1.2 1.2 3.2 3.2 5.6 5.6 1.2 1.2 3.1 3.1 5.4 5.4 0.9 0.9 0.9 0.9 0.9 0.9 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 18.2 18.2 4.1 4.1 9.7 9.7 16.5 16.5 3.6 3.6 8.8 8.8 15.2 15.2 3.2 3.2 8.1 8.1 14.3 14.3 3.0 3.0 7.6 7.6 13.5 13.5 2.9 2.9 7.3 7.3 13.0 13.0 2.8 2.8 7.1 7.1 12.6 12.6 2.0 2.0 2.0 2.0 2.0 2.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 CFM HC kW COP HE 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 1520 1900 39.3 39.9 42.3 43.0 43.9 44.7 44.8 45.6 47.8 48.6 49.9 50.7 51.0 51.9 53.7 54.7 56.3 57.3 57.7 58.7 59.9 61.0 62.9 64.0 64.6 65.7 66.3 67.4 69.6 70.8 71.4 72.7 72.5 73.8 76.2 77.5 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 77.4 78.8 3.81 3.66 3.87 3.72 3.90 3.75 3.92 3.77 3.99 3.84 4.04 3.88 4.07 3.91 4.13 3.97 4.20 4.04 4.23 4.07 4.30 4.13 4.37 4.20 4.42 4.25 4.46 4.29 4.56 4.38 4.61 4.43 4.64 4.46 4.75 4.57 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 4.78 4.60 3.0 3.2 3.2 3.4 3.3 3.5 3.3 3.5 3.5 3.7 3.6 3.8 3.7 3.9 3.8 4.0 3.9 4.2 4.0 4.2 4.1 4.3 4.2 4.5 4.3 4.5 4.4 4.6 4.5 4.7 4.5 4.8 4.6 4.8 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 4.7 5.0 26.3 27.5 29.1 30.3 30.6 31.9 31.4 32.7 34.2 35.5 36.1 37.5 37.2 38.6 39.7 41.1 42.0 43.5 43.2 44.8 45.3 46.9 48.0 49.7 49.5 51.2 51.0 52.8 54.1 55.9 55.7 57.6 56.7 58.6 60.0 61.9 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 61.1 63.1 LAT 93.9 89.5 95.8 91.0 96.8 91.8 97.3 92.2 99.1 93.7 100.4 94.7 101.1 95.3 102.7 96.6 104.3 97.9 105.1 98.6 106.5 99.7 108.3 101.2 109.3 102.0 110.4 102.9 112.4 104.5 113.5 105.4 114.2 106.0 116.4 107.8 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 117.2 108.4 LWT HWC 16.2 16.1 21.7 21.3 24.2 23.9 25.5 25.3 30.2 29.8 33.1 32.9 34.7 34.5 38.7 38.3 42.0 41.7 43.8 43.6 47.1 46.6 50.9 50.5 52.9 52.7 55.4 54.9 59.7 59.4 62.0 61.8 63.8 63.3 68.6 68.2 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 4.6 4.5 4.8 4.7 4.9 4.8 4.9 4.8 5.2 5.0 5.4 5.2 5.4 5.2 5.6 5.4 5.8 5.6 5.9 5.7 6.1 5.9 6.3 6.1 6.5 6.3 6.6 6.4 6.9 6.7 7.1 6.9 7.2 7.0 7.6 7.4 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 7.7 7.5 All performance is based upon the lower voltage of dual voltage rated units. Operation at or below 40° F EWT is based on 15% methanol antifreeze solution. See Performance correction tables for operating conditions other than those listed above. c l i m a t e m a s t e r. c o m 49 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Preventive Maintenance Water Coil Maintenance (Direct ground water applications only) - If the system is installed in an area with a known high mineral content (125 P.P.M. or greater) in the water, it is best to establish a periodic maintenance schedule with the owner so the coil can be checked regularly. Consult the well water applications section of this manual for a more detailed water coil material selection. Should periodic coil cleaning be necessary, use standard coil cleaning procedures, which are compatible with the heat exchanger material and copper water lines. Generally, the more water flowing through the unit, the less chance for scaling. Therefore, 1.5 gpm per ton [2.0 l/m per kW] is recommended as a minimum flow. Minimum flow rate for entering water temperatures below 50°F [10°C] is 2.0 gpm per ton [2.6 l/m per kW]. Water Coil Maintenance (All other water loop applications) Generally water coil maintenance is not needed for closed loop systems. However, if the piping is known to have high dirt or debris content, it is best to establish a periodic maintenance schedule with the owner so the water coil can be checked regularly. Should periodic coil cleaning be necessary, use standard coil cleaning procedures, which are compatible with both the heat exchanger material and copper water lines. Generally, the more water flowing through the unit, the less chance for scaling. However, flow rates over 3 gpm per ton (3.9 l/m per kW) may produce water (or debris) velocities that can erode the heat exchanger wall and ultimately produce leaks. Hot Water Generator Coils See water coil maintenance for ground water units. If the potable water is hard or not chemically softened, the high temperatures of the desuperheater will tend to scale even quicker than the water coil and may need more frequent inspections. In areas with extremely hard water, a HWG is not recommended. three months to minimize the problem. The condensate pan may also need to be cleaned periodically to insure indoor air quality. The condensate drain can pick up lint and dirt, especially with dirty filters. Inspect the drain twice a year to avoid the possibility of plugging and eventual overflow. Compressor Conduct annual amperage checks to insure that amp draw is no more than 10% greater than indicated on the serial plate data. Fan Motors All residential units have permanently lubricated fan motors. Further lubrication is not recommended. Conduct annual amperage check to insure amp draw is no more than 10% greater than indicated on serial data plate. Air Coil The air coil must be cleaned to obtain maximum performance. Check once a year under normal operating conditions and, if dirty, brush or vacuum clean. Care must be taken not to damage the aluminum fins while cleaning. CAUTION: Fin edges are sharp. Cabinet Do not allow water to stay in contact with the cabinet for long periods of time to prevent corrosion of the cabinet sheet metal. Generally, vertical cabinets are set up from the floor a few inches [7 - 8 cm] to prevent water from entering the cabinet. The cabinet can be cleaned using a mild detergent. Refrigerant System To maintain sealed circuit integrity, do not install service gauges unless unit operation appears abnormal. Reference the operating charts for pressures and temperatures. Verify that air and water flow rates are at proper levels before servicing the refrigerant circuit. Filters Filters must be clean to obtain maximum performance. Filters should be inspected every month under normal operating conditions and be replaced when necessary. Units should never be operated without a filter. Washable, high efficiency, electrostatic filters, when dirty, can exhibit a very high pressure drop for the fan motor and reduce air flow, resulting in poor performance. It is especially important to provide consistent washing of these filters (in the opposite direction of the normal air flow) once per month using a high pressure wash similar to those found at selfserve car washes. Condensate Drain In areas where airborne bacteria may produce a “slimy” substance in the drain pan, it may be necessary to treat the drain pan chemically with an algaecide approximately every 50 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Troubleshooting General If operational difficulties are encountered, perform the preliminary checks below before referring to the troubleshooting charts. • Verify that the unit is receiving electrical supply power. • Make sure the fuses in the fused disconnect switches are intact. After completing the preliminary checks described above, inspect for other obvious problems such as leaking connections, broken or disconnected wires, etc. If everything appears to be in order, but the unit still fails to operate properly, refer to the “DXM2 Troubleshooting Process Flowchart” or “Functional Troubleshooting Chart.” DXM2 Board DXM2 board troubleshooting in general is best summarized as verifying inputs and outputs. After inputs and outputs have been verified, board operation is confirmed and the problem must be elsewhere. Below are some general guidelines for troubleshooting the DXM2 control. Field Inputs Conventional thermostat inputs are 24VAC from the thermostat and can be verified using a voltmeter between C and Y1, Y2, W, O, G. 24VAC will be present at the terminal (for example, between “Y1” and “C”) if the thermostat is sending an input to the DXM2 board. Proper communications with a thermostat can be verified using the Fault LED on the DXM2. If the control is NOT in the Test mode and is NOT currently locked out or in a retry delay, the Fault LED on the DXM2 will flash very slowly (1 second on, 5 seconds off), if the DXM2 is properly communicating with the thermostat. Sensor Inputs All sensor inputs are ‘paired wires’ connecting each component to the board. Therefore, continuity on pressure switches, for example can be checked at the board connector. The thermistor resistance should be measured with the connector removed so that only the impedance of the thermistor is measured. If desired, this reading can be compared to the thermistor resistance chart shown in Table 17. An ice bath can be used to check the calibration of the thermistor. Table 16: Nominal resistance at various temperatures Temp (ºC) Temp (ºF) -17.8 -17.5 -16.9 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 0.0 0.5 1.5 10.4 12.2 14.0 15.8 17.6 19.4 21.2 23.0 24.8 26.6 28.4 30.2 32.0 33.8 35.6 37.4 39.2 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 57.2 59.0 60.8 62.6 64.4 66.2 68.0 69.8 71.6 73.4 75.2 77.0 78.8 80.6 82.4 84.2 86.0 87.8 89.6 91.4 93.2 95.0 96.8 98.6 100.4 102.2 104.0 105.8 107.6 109.4 111.2 113.0 114.8 116.6 118.4 120.2 122.0 123.8 125.6 127.4 129.2 c l i m a t e m a s t e r. c o m Resistance (kOhm) 85.34 84.00 81.38 61.70 58.40 55.30 52.38 49.64 47.05 44.61 42.32 40.15 38.11 36.18 34.37 32.65 31.03 29.50 28.05 26.69 25.39 24.17 23.02 21.92 20.88 19.90 18.97 18.09 17.26 16.46 15.71 15.00 14.32 13.68 13.07 12.49 11.94 11.42 10.92 10.45 10.00 9.57 9.16 8.78 8.41 8.06 7.72 7.40 7.10 6.81 6.53 6.27 6.01 5.77 5.54 5.33 5.12 4.92 4.72 4.54 4.37 4.20 4.04 3.89 3.74 3.60 3.47 3.34 3.22 3.10 Temp (ºC) Temp (ºF) 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 131.0 132.8 134.6 136.4 138.2 140.0 141.8 143.6 145.4 147.2 149.0 150.8 152.6 154.4 156.2 158.0 159.8 161.6 163.4 165.2 167.0 168.8 170.6 172.4 174.2 176.0 177.8 179.6 181.4 183.2 185.0 186.8 188.6 190.4 192.2 194.0 195.8 197.6 199.4 201.2 203.0 204.8 206.6 208.4 210.2 212.0 213.8 215.6 217.4 219.2 221.0 222.8 224.6 226.4 228.2 230.0 231.8 233.6 235.4 237.2 239.0 240.8 242.6 244.4 246.2 248.0 249.8 251.6 253.4 Resistance (kOhm) 2.99 2.88 2.77 2.67 2.58 2.49 2.40 2.32 2.23 2.16 2.08 2.01 1.94 1.88 1.81 1.75 1.69 1.64 1.58 1.53 1.48 1.43 1.39 1.34 1.30 1.26 1.22 1.18 1.14 1.10 1.07 1.04 1.01 0.97 0.94 0.92 0.89 0.86 0.84 0.81 0.79 0.76 0.74 0.72 0.70 0.68 0.66 0.64 0.62 0.60 0.59 0.57 0.55 0.54 0.52 0.51 0.50 0.48 0.47 0.46 0.44 0.43 0.42 0.41 0.40 0.39 0.38 0.37 0.36 51 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Troubleshooting Outputs The compressor and reversing valve relays are 24VAC and can be verified using a voltmeter. For units with ECM blower motors, the DXM2 controls the motor using serial communications, and troubleshooting should be done with a communicating thermostat or diagnostic tool. The alarm relay can either be 24VAC as shipped or dry contacts for use with DDC controls by clipping the JW1 jumper. Electric heat outputs are 24VDC “ground sinking” and require a voltmeter set for DC to verify operation. The terminal marked “24VDC” is the 24VDC supply to the electric heat board; terminal “EH1” is stage 1 electric heat; terminal “EH2” is stage 2 electric heat. When electric heat is energized (thermostat is sending a “W” input to the DXM2 controller), there will be 24VDC between terminal “24VDC” and “EH1” (stage 1 electric heat) and/or “EH2” (stage 2 electric heat). A reading of 0VDC between “24VDC” and “EH1” or “EH2” will indicate that the DXM2 board is NOT sending an output signal to the electric heat board. Test Mode Test mode can be entered for 20 minutes by pressing the Test pushbutton. The DXM2 board will automatically exit test mode after 20 minutes. Advanced Diagnostics To properly troubleshoot advanced control features, and to aid in troubleshooting basic control features, a communicating thermostat or diagnostic tool must be used. Service Mode The Service Mode provides the installer with several functions for troubleshooting, including Manual Operation, Control Diagnostics, Control Configuration, and Fault History. Manual Operation – The Manual Operation mode allows the installer to bypass normal thermostat timings and operating modes, to directly activate the thermostat inputs to the DXM2, activate the DXM2 Test mode, and directly control the ECM blower, internal flow center, and proportional valve. Control Diagnostics – The Control Diagnostics menus allow the installer to see the current status of all DXM2 control switch inputs, values of all temperature sensor inputs, control voltage, ECM blower, internal flow center, and proportional valve operating status and parameters. Dipswitch Configuration – The Dipswitch Configuration menus allow the installer to easily see the current DXM2 control configuration. values when the lockout occurred. Fault Temp Conditions – This option displays the DXM2 temperature and voltage values when the lockout occurred. Fault Flow Conditions – This option displays the DXM2 ECM blower, pump, and valve operating parameters when the lockout occurred. Fault I/O Conditions – This option displays the status of the DXM2 physical and communicated inputs and the relay outputs when the lockout occurred. Fault Configuration Conditions – This option displays the status of the DXM2 option selections when the lockout occurred. Fault Possible Causes – This option displays a list of potential causes of the stored fault. Clear Fault History – The Clear Fault History option allows the fault history stored in the non-volatile memory of the DXM2 to be cleared. DXM2 Troubleshooting Process Flowchart/Functional Troubleshooting Chart The “DXM2 Functional Troubleshooting Process Flowchart” is a quick overview of how to start diagnosing a suspected problem, using the fault recognition features of the DXM2 board. The “Functional Troubleshooting Chart” on the following page is a more comprehensive method for identifying a number of malfunctions that may occur, and is not limited to just the DXM2 controls. Within the chart are five columns: • The “Fault” column describes the symptoms. • Columns 2 and 3 identify in which mode the fault is likely to occur, heating or cooling. • The “Possible Cause column” identifies the most likely sources of the problem. • The “Solution” column describes what should be done to correct the problem. WARNING! WARNING! HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. Failure to disconnect power before servicing can cause severe personal injury or death. Fault History – In addition to the fault code, the DXM2 stores the status of all control inputs and outputs when a fault condition is detected. The fault history covering the last five lockout conditions is stored and may be retrieved from the DXM2. After a specific fault in the fault history is selected, the operating mode and time when the fault occurred are displayed, with options to select specific control status 52 Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B DXM2 Process Flow Chart WARNING! WARNING! HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. Failure to disconnect power before servicing can cause severe personal injury or death. Start Did Unit Attempt to Start? DXM2 Functional Troubleshooting Flow Chart No Check Main power (see power problems) Yes Did Unit Lockout at Start-up? No See “ Unit short cycles” Yes Yes Check fault code on communicating thermostat (ATC32) or Configuration and Diagnostics Tool (ACD01) Unit Short Cycles? No fault shown Replace DXM2 No See “ Only Fan Runs” Yes See “ Only Yes Comp Runs” Only Fan Runs? See fault codes in table on following page No Only Compressor Runs? No Did unit lockout Yes after a period of operation? No Does unit See “ Does No operate in not Operate cooling? in Clg” Yes Unit is OK! ‘See Performance Troubleshooting’ for further help c l i m a t e m a s t e r. c o m 53 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Functional Troubleshooting Fault Main Power Problems HP Fault Code 2 High Pressure LP/LOC Fault-Code 3 Low Pressure/Loss of Charge LT1 Fault - Code 4 Water Low Temperature Htg Clg Possible Cause X Green status LED off X Reduced or no water flow in cooling X Water t emperature out of range in Bring water temp within design parameters cooling X Reduced or no air flow in heating Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Dirty air coil- construction dust etc. Too high of external static. Check static vs blower table X Air t emperature out of range in heating Bring return air temp within design parameters X X Overcharged with refrigerant Check superheat/subcooling vs typical operating condition table X X Bad HP switch Check switch continuity and operation - Replace X X X Frozen water heat exchanger Bad HPWS Switch Thaw heat exchanger Replace HPWS Switch X X Insufficient charge Check for refrigerant leaks X Compressor pump down at startup Check charge and start-up water flow X Reduced or no water flow in heating Plugged strainer or filter - clean or replace X Inadequate anti-freeze level Check antifreeze density with hydrometer X Improper low temperature setting Clip LT1 jumper for antifreeze (10°F) use (30°F vs 10°F) X Water t emperature out of range Check pump operation or water valve operation/setting Check water flow adjust to proper flow rate Bring water temp within design parameters Check temp and impedance correlation per chart Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table X Bad thermistor X Reduced or no air flow in cooling X Air temperature out of range X Improper low temperature setting Normal airside applications will require 30°F only (30°F vs 10°F) X X Bad thermistor Check temp and impedance correlation per chart X X X X Blocked drain Improper trap X Poor drainage X Check for blockage and clean drain Check trap dimensions and location ahead of vent Check for piping slope away from unit Check slope of unit toward outlet Poor venting - check vent location Check for moisture shorting to air coil Replace air filter LT2 Fault - Code 5 Low Air Temperature Condensate Fault-Code 6 High Condensate Level 54 Check Line Voltage circuit breaker and disconnect Check for line voltage between L1 and L2 on the contactor Check for 24VAC between R and C on DXM Check primary/secondary voltage on transformer Check pump operation or valve operation/setting Check water flow adjust to proper flow rate X X Over/Under Voltage-Code 7 (Auto Resetting) Solution X X Moisture on sensor Plugged air filter X X Restricted return air flow X X Under voltage X X Over voltage Too much cold vent air - bring entering air temp within design parameters Find and eliminate rectriction - increase return duct and/or grille size Check power supply and 24VAC voltage before and during operation Check power supply wire size Check compressor starting. Need hard start kit? Check 24VAC and unit transformer tap for correct power supply voltage Check power supply voltage and 24VAC before and during operation. Check 24VAC and unit transformer tap for correct power supply voltage Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Functional Troubleshooting (cont.) Fault Unit Performance Sentinel-Code 8 Swapped Thermistor Code 9 Htg Clg Possible Cause X Solution Heating Mode LT2>125°F Check for poor air flow or overcharged unit X Cooling Mode LT1>125°F OR LT2< 40°F Check for poor water flow, or air flow X X LT1 and LT2 swapped Reverse position of thermistors X X Blower does not operate Check blower line voltage Check blower low voltage wiring Blower operating with incorrect airflow ECM Fault - Code 10 Wrong unit size selection Wrong unit family selection Wrong motor size Incorrect blower selection Check for dirty air filter and clean or replace Performance Troubleshooting Reduced or no air flow in cooling Low Air Coil Pressure Fault (ClimaDry) Code 11 X Air temperature out of range Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table Too much cold vent air - bring entering air temp within design parameters Bad pressure switch Check switch continuity and operation - replace Reduced airflow in cooling, ClimaDry, or constant fan Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table Too much cold vent air - bring entering air temp within design parameters or ClimaDry Low Air Coil Temperature Fault - (ClimaDry) Code 12 X Air temperature out of range IFC Fault Code 13 Internal Flow Controller Fault X X Bad thermistor Check temp and impedance correlation per chart No pump output signal Check DC voltage between A02 and GND - should be between 0.5 and 10 VDC with pump active Low pump voltage Check line voltage to the pump No pump feedback signal Check DC voltage between T1 and GND. Voltage should be between 3 and 4 VDC with pump OFF, and between 0 and 2 VDC with the pump ON Bad pump RPM sensor Replace pump if the line voltage and control signals are present at the pump, and the pump does not operate ESD - ERV Fault (DXM Only) Green Status LED Code 3 X X X No compressor operation See 'Only Fan Operates' No Fault Code Shown X X Compressor overload Check and replace if necessary X X X X X X Control board Dirty air filter Unit in 'Test Mode' X X Unit selection X X X X Compressor overload Thermostat position Reset power and check operation Check and clean air filte r Reset power or wait 20 minutes for auto exit Unit may be oversized for space - check sizing for actual load of space Check and replace if necessary Insure thermostat set for heating or cooling operation Unit Short Cycles Only Fan Runs X ERV unit has fault (Rooftop units only) Troubleshoot ERV unit fault X X Unit locked out Check for lockout codes - reset power X X Compressor overload Check compressor overload - replace if necessary X X Thermostat wiring Check thermostat wiring at DXM2 - put in Test Mode and jumper Y1 and R to give call for compressor c l i m a t e m a s t e r. c o m 55 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Performance Troubleshooting Symptom Htg Clg Possible Cause X X Rduced or no air flow in heating X Insufficient Capacity/ Not Cooling or Heating Properly Replace or clean Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table Check supply and return air temperatures at the unit and at distant duct registers if significantly different, duct leaks are present Check superheat and subcooling per chart Check superheat and subcooling per chart - replace Perform RV touch test Check location and for air drafts behind stat Recheck loads & sizing check sensible clg load and heat pump capacity X Reduced or no air flow in cooling X X Leaky duct work X X X X X X X Low refrigerant charge Restricted metering device Defective reversing va lve Thermostat improperly located X X Unit undersized X X Scaling in water heat exchanger Perform Scaling check and clean if necessary X X Inlet water too hot or cold Check load, loop sizing, loop backfill, ground moisture Reduced or no air flow in heating X X High Head Pressure X X X X X X X X X Too high of external static - check static vs blower table Check pump operation or valve operation/setting Check water flow adjust to proper flow rate Check load, loop sizing, loop backfill, ground moisture Scaling in water heat exchanger Unit over charged Non-condensables insystem Restricted metering device Perform Scaling check and clean if necessary Check superheat and subcooling - reweigh in charge Vacuum system and reweigh in charge Check superheat and subcooling per chart - replace Check pump operation or water valve operation/setting Plugged strainer or filter - clean or replace Check water flow adjust to proper flow rate Reduced water flow in heating X Water temperature out of range X Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Reduced or no water flow in cooling Inlet w ater too hot Air temperature out of range in heating X Low Suction Pressure 56 Dirty filter Solution X Reduced air flow in cooling X Air temperature out of range X Insufficient charge Bring return air temp within design parameters Bring water temp within design parameters Check for dirty air filter and clean or replace Check fan motor operation and airflow restrictions Too high of external static - check static vs blower table Too much cold vent air - bring entering air temp within design parameters Check for refrigerant leaks Geothermal Heat Pump Systems Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Performance Troubleshooting (cont.) Symptom Low Dischage Air Temperature in Heating Htg Clg Possible Cause X Too high of air flow Check fan motor speed selection and airflow chart X Poor performance Too high of air flow X Unit oversized See “Insufficient Capacity” Check fan motor speed selection and airflow chart Recheck loads and sizing check sensible clg load and heat pump capacity X X Thermostat wiring Check G wiring at heat pump. Jumper G and R for fan operation. X X Fan motor relay Jumper G and R for fan operation. Check for Line voltage across blower relay contacts. Check fan power enable relay operation (if present) X X Fan motor Check for line voltage at motor. Check capacitor X X Thermostat wiring Check thermostat wiring at or DXM2. Put in Test Mode and then jumper Y1 and W1 to R to give call for fan, compressor and electric heat. X Reversing Valve X Thermostat setup X Thermostat wiring Set for cooling demand and check 24VAC on RV coil. If RV is stuck, run high pressure up by reducing water flow and while operating engage and disengage RV coil voltage to push valve. For DXM2 check for “O” RV setup not “B”. Check O wiring at heat pump. DXM2 requires call for compressor to get RV coil “Click.” Improper output setting Verify the AO-2 jumper is in the 0-10V position No valve output signal Check DC voltage between AO2 and GND. Should be O when valve is off and between 3.3v and 10v when valve is on. Check voltage to the valve Replace valve if voltage and control signals are present at the valve and it does not operate X High Humidity Only Compressor Runs Unit Doesn't Operate in Cooling Modulating Valve Troubleshooting Solution X X No valve operation To Diagnose Communicating fan, please reference “Nidec PerfectSpeed COMMUNICATING Motor Troubleshooting Manual” (RP921) . Using the UltraCheck-EZ® diagnostic tool makes diagnosis even faster and more accurate (Part number: AULTRACHK) c l i m a t e m a s t e r. c o m 57 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Troubleshooting Form Refrigerant Circuit Diagram Customer: Loop Type: Model #: Serial #: Startup Date: Antifreeze Type & %: Complaint: REFRIGERANT: R-22 OPERATING MODE: R-410A HEATING R-407C HEATING POSITION COOLING POSITION COOLING WATER-TO-AIR UNITS WATER-TO-WATER UNITS 11 13 10 12 14 REFRIG FLOW - COOLING 15 AIR COIL COAX Load REFRIG FLOW - HEATING CONDENSER (HEATING) EVAPORATOR (COOLING) REVERSING VALVE 2 1 SUCTION CONDENSER (COOLING) EVAPORATOR (HEATING) COMPRESSOR 3 EXPANSION VALVE CONDENSER (HT G) EVAPORAT OR (CLG) COAX FILTER DRIER* DISCHARGE HWG** 4 Source 5 LT2: *Filter drier not used for some R-22 units. **Turn off HWG before troubleshooting. 1 2 2a 2b 3 4 4a 4b 5 6 7 8 9 9a 9b 10 11 12 13 13a 13b 14 15 Description Voltage Compress Amps Suction Temp Suction Press Saturation Temp Superheat Discharge Temp Discharge Press Saturation Temp Subcooling Liquid Line Temp 5 LT1: HEATING LIQUID LINE COOLING LIQUID LINE Heating 6 7 8 9 Cooling Source Water In Tmp Source Water Out Tmp Source Water In Pres Source Water Out Pres Notes Temp Diff. = Press Drop GPM <--Water-to-Water units only Temp Diff. = <--Water-to-Water units only <--Water-to-Water units only <--Water-to-Water units only <--Water-to-Water units only <--Water-to-Air units only Temp Diff. = Load Water In Temp Load Water Out Temp Load Water In Pres Load Water Out Pres Press Drop GPM Return Air Temp Supply Air Temp Heat of Extraction (Absorption) or Heat of Rejection: HE or HR (Btuh) = Flow Rate (GPM) x Enter HE or HR: Temp. Diff (deg F) x Fluid Factor: 500 (Water); 485 (Antifreeze) Fluid Factor Note: Never connect refrigerant gauges during startup procedures. Conduct water-side analysis using P/T ports to determine water flow and temperature difference. If water-side analysis shows poor performance, refrigerant troubleshooting may be required. Connect refrigerant gauges as a last resort. 58 Geothermal Heat Pump Systems c l i m a t e m a s t e r. c o m 3OHDVHUHIHUWRWKH&0,QVWDOODWLRQ2SHUDWLRQDQG0DLQWHQDQFH0DQXDOIRURSHUDWLQJDQGPDLQWHQDQFHLQVWUXFWLRQV 5HY 3DUW1R53 127(6RPHVWDWHVRU&DQDGLDQSURYLQFHVGRQRWDOORZOLPLWDWLRQVRQKRZORQJDQLPSOLHGZDUUDQW\ODVWVRUWKHOLPLWDWLRQRUH[FOXVLRQVRIFRQVHTXHQWLDORULQFLGHQWDOGDPDJHVVRWKHIRUHJRLQJH[FOXVLRQVDQGOLPLWDWLRQVPD\QRWDSSO\WR\RX 7KLVZDUUDQW\JLYHV\RXVSHFL¿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¶VSHUIRUPDQFHLVGHOD\HGIRUDQ\UHDVRQRULVSUHYHQWHGWRDQ\H[WHQWE\DQ\HYHQWVXFKDVEXWQRWOLPLWHGWRDQ\ZDUFLYLOXQUHVWJRYHUQPHQWUHVWULFWLRQVRUUHVWUDLQWVVWULNHVRU ZRUNVWRSSDJHV¿UHÀRRGDFFLGHQWVKRUWDJHVRIWUDQVSRUWDWLRQIXHOPDWHULDORUODERUDFWVRI*RGRUDQ\RWKHUUHDVRQEH\RQGWKHVROHFRQWURORI&0&0(;35(66/<',6&/$,06$1'(;&/8'(6$1</,$%,/,7<)25 &216(48(17,$/25,1&,'(17$/'$0$*(,1&2175$&7)25%5($&+2)$1<(;35(6625,03/,(':$55$17<25,17257:+(7+(5)25&0¶V1(*/,*(1&(25$6675,&7/,$%,/,7< /,0,7$7,212)5(0(',(6 ,QWKHHYHQWRIDEUHDFKRIWKH/LPLWHG([SUHVV:DUUDQW\&0ZLOORQO\EHREOLJDWHGDW&0¶VRSWLRQWRUHSDLUWKHIDLOHGSDUWRUXQLWRUWRIXUQLVKDQHZRUUHEXLOWSDUWRUXQLWLQH[FKDQJHIRUWKHSDUWRUXQLWZKLFKKDVIDLOHG,IDIWHUZULWWHQQRWLFH WR&0¶VIDFWRU\LQ2NODKRPD&LW\2NODKRPDRIHDFKGHIHFWPDOIXQFWLRQRURWKHUIDLOXUHDQGDUHDVRQDEOHQXPEHURIDWWHPSWVE\&0WRFRUUHFWWKHGHIHFWPDOIXQFWLRQRURWKHUIDLOXUHDQGWKHUHPHG\IDLOVRILWVHVVHQWLDOSXUSRVH&0VKDOO UHIXQGWKHSXUFKDVHSULFHSDLGWR&0LQH[FKDQJHIRUWKHUHWXUQRIWKHVROGJRRGV6DLGUHIXQGVKDOOEHWKHPD[LPXPOLDELOLW\RI&07+,65(0('<,67+(62/($1'(;&/86,9(5(0('<2)7+(%8<(525385&+$6(5 $*$,167&0)25%5($&+2)&2175$&7)257+(%5($&+2)$1<:$55$17<25)25&0¶61(*/,*(1&(25,1675,&7/,$%,/,7< /LPLWDWLRQ7KLV/LPLWHG([SUHVV:DUUDQW\LVJLYHQLQOLHXRIDOORWKHUZDUUDQWLHV,IQRWZLWKVWDQGLQJWKHGLVFODLPHUVFRQWDLQHGKHUHLQLWLVGHWHUPLQHGWKDWRWKHUZDUUDQWLHVH[LVWDQ\VXFKH[SUHVVZDUUDQW\LQFOXGLQJZLWKRXWOLPLWDWLRQDQ\ H[SUHVVZDUUDQWLHVRUDQ\LPSOLHGZDUUDQWLHVRI¿WQHVVIRUSDUWLFXODUSXUSRVHDQGPHUFKDQWDELOLW\VKDOOEHOLPLWHGWRWKHGXUDWLRQRIWKH/LPLWHG([SUHVV:DUUDQW\ 7KLV/LPLWHG([SUHVV:DUUDQW\DSSOLHVWR&05HVLGHQWLDO&ODVVSURGXFWVRUGHUHGIURP&0RQRUDIWHU0D\WKLVZRXOGJHQHUDOO\LQFOXGH&08QLWVZLWKVHULDOQXPEHUVEHJLQQLQJZLWK³1´DQGKLJKHUDQGLVQRWUHWURDFWLYHWRDQ\ SURGXFWVRUGHUHGIURP&0SULRUWR0D\WKLVZRXOGJHQHUDOO\LQFOXGH&08QLWVZLWKVHULDOQXPEHUVEHJLQQLQJZLWK³1´DQGORZHU,I\RXDUHXQVXUHLIWKLV/LPLWHG([SUHVV:DUUDQW\DSSOLHVWRWKHSURGXFW\RXKDYHSXUFKDVHG FRQWDFW&0DWWKHSKRQHQXPEHURUDGGUHVVUHÀHFWHGEHORZ 7KLV/LPLWHG([SUHVV:DUUDQW\SURYLGHVWKHOLPLWHGODERUDOORZDQFHFRYHUDJHDVVHWIRUWKDERYH2WKHUZLVH&0LVQRWUHVSRQVLEOHIRU7KHFRVWVRIDQ\ÀXLGVUHIULJHUDQWRUV\VWHPFRPSRQHQWVVXSSOLHGE\RWKHUVRUDVVRFLDWHGODERUWRUHSDLU RUUHSODFHWKHVDPHZKLFKLVLQFXUUHGDVDUHVXOWRIDGHIHFWLYHSDUWFRYHUHGE\&0¶V/LPLWHG([SUHVV:DUUDQW\7KHFRVWVRIODERUUHIULJHUDQWPDWHULDOVRUVHUYLFHLQFXUUHGLQGLDJQRVLVDQGUHPRYDORIWKHGHIHFWLYHSDUWRULQREWDLQLQJDQG UHSODFLQJWKHQHZRUUHSDLUHGSDUW7UDQVSRUWDWLRQFRVWVRIWKHGHIHFWLYHSDUWIURPWKHLQVWDOODWLRQVLWHWR&0RURIWKHUHWXUQRIWKDWSDUWLIQRWFRYHUHGE\&0¶V/LPLWHG([SUHVV:DUUDQW\RU7KHFRVWVRIQRUPDOPDLQWHQDQFH 7KLVZDUUDQW\GRHVQRWFRYHUDQGGRHVQRWDSSO\WR$LU¿OWHUVIXVHVUHIULJHUDQWÀXLGVRLO3URGXFWVUHORFDWHGDIWHULQLWLDOLQVWDOODWLRQ$Q\SRUWLRQRUFRPSRQHQWRIDQ\V\VWHPWKDWLVQRWVXSSOLHGE\&0UHJDUGOHVVRIWKHFDXVHRIWKH IDLOXUHRIVXFKSRUWLRQRUFRPSRQHQW3URGXFWVRQZKLFKWKHXQLWLGHQWL¿FDWLRQWDJVRUODEHOVKDYHEHHQUHPRYHGRUGHIDFHG3URGXFWVRQZKLFKSD\PHQWWR&0RUWRWKHRZQHU¶VVHOOHURULQVWDOOLQJFRQWUDFWRULVLQGHIDXOW3URGXFWV VXEMHFWHGWRLPSURSHURULQDGHTXDWHLQVWDOODWLRQPDLQWHQDQFHUHSDLUZLULQJRUYROWDJHFRQGLWLRQV3URGXFWVVXEMHFWHGWRDFFLGHQWPLVXVHQHJOLJHQFHDEXVH¿UHÀRRGOLJKWQLQJXQDXWKRUL]HGDOWHUDWLRQPLVDSSOLFDWLRQFRQWDPLQDWHG RUFRUURVLYHDLURUOLTXLGVXSSO\RSHUDWLRQDWDEQRUPDODLURUOLTXLGWHPSHUDWXUHVRUÀRZUDWHVRURSHQLQJRIWKHUHIULJHUDQWFLUFXLWE\XQTXDOL¿HGSHUVRQQHO0ROGIXQJXVRUEDFWHULDGDPDJHV&RUURVLRQRUDEUDVLRQRIWKHSURGXFW 3URGXFWVVXSSOLHGE\RWKHUV3URGXFWVZKLFKKDYHEHHQRSHUDWHGLQDPDQQHUFRQWUDU\WR&0¶VSULQWHGLQVWUXFWLRQV3URGXFWVZKLFKKDYHLQVXI¿FLHQWSHUIRUPDQFHDVDUHVXOWRILPSURSHUV\VWHPGHVLJQRULPSURSHUDSSOLFDWLRQ LQVWDOODWLRQRUXVHRI&0¶VSURGXFWVRU(OHFWULFLW\RUIXHOFRVWVRUDQ\LQFUHDVHVRUXQUHDOL]HGVDYLQJVLQVDPHIRUDQ\UHDVRQZKDWVRHYHU 7KLV/LPLWHG([SUHVV:DUUDQW\VKDOOFRYHUWKHODERULQFXUUHGE\&0DXWKRUL]HGVHUYLFHSHUVRQQHOLQFRQQHFWLRQZLWKWKHLQVWDOODWLRQRIDQHZRUUHSDLUHGZDUUDQW\SDUWWKDWLVFRYHUHGE\WKLV/LPLWHG([SUHVV:DUUDQW\RQO\WRWKHH[WHQW VSHFL¿FDOO\VHWIRUWKLQWKHWKHQH[LVWLQJODERUDOORZDQFHVFKHGXOHSURYLGHGE\&0¶V:DUUDQW\'HSDUWPHQWDQGRQO\DVIROORZV&08QLWVIRU¿YH\HDUVIURPWKH:DUUDQW\,QFHSWLRQ'DWH7KHUPRVWDWVDX[LOLDU\HOHFWULFKHDWHUVDQG JHRWKHUPDOSXPSLQJPRGXOHVEXLOWRUVROGE\&0ZKHQLQVWDOOHGZLWK&08QLWVIRU¿YH\HDUVIURPWKH:DUUDQW\,QFHSWLRQ'DWH$FWXDO/DERUFRVWVDUHQRWFRYHUHGE\WKLV/LPLWHG([SUHVV:DUUDQW\WRWKHH[WHQWWKH\H[FHHGWKHDPRXQW DOORZHGXQGHUVDLGDOORZDQFHVFKHGXOHWKH\DUHQRWVSHFL¿FDOO\SURYLGHGIRULQVDLGDOORZDQFHVFKHGXOHWKH\DUHQRWWKHUHVXOWRIZRUNSHUIRUPHGE\&0DXWKRUL]HGVHUYLFHSHUVRQQHOWKH\DUHLQFXUUHGLQFRQQHFWLRQZLWKDSDUWQRWFRYHUHGE\ WKLV/LPLWHG([SUHVV:DUUDQW\RUWKH\DUHLQFXUUHGPRUHWKDQWKHWLPHSHULRGVVHWIRUWKLQWKLVSDUDJUDSKDIWHUWKH:DUUDQW\,QFHSWLRQ'DWH 7RPDNHDFODLPXQGHUWKLVZDUUDQW\SDUWVPXVWEHUHWXUQHGWR&0LQ2NODKRPD&LW\2NODKRPDIUHLJKWSUHSDLGQRODWHUWKDQQLQHW\GD\VDIWHUWKHGDWHRIWKHIDLOXUHRIWKHSDUWLI&0GHWHUPLQHVWKHSDUWWREHGHIHFWLYHDQGZLWKLQ&0¶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³&08QLWV´IRUWHQ\HDUVIURPWKH:DUUDQW\,QFHSWLRQ'DWHDVGH¿QHGEHORZ7KHUPRVWDWVDX[LOLDU\HOHFWULFKHDWHUVDQGJHRWKHUPDOSXPSLQJPRGXOHVEXLOWRUVROGE\&0ZKHQLQVWDOOHG ZLWK&08QLWVIRUWHQ\HDUVIURPWKH:DUUDQW\,QFHSWLRQ'DWHDVGH¿QHGEHORZDQG2WKHUDFFHVVRULHVDQGSDUWVEXLOWRUVROGE\&0ZKHQLQVWDOOHGZLWK&08QLWVIRURQH\HDUIURPWKHGDWHRIVKLSPHQWIURP&07KH³:DUUDQW\ ,QFHSWLRQ'DWH´VKDOOEHWKHGDWHRIRULJLQDOXQLWLQVWDOODWLRQRUVL[PRQWKVIURPGDWHRIXQLWVKLSPHQWIURP&0ZKLFKHYHUFRPHV¿UVW ,WLVH[SUHVVO\XQGHUVWRRGWKDWXQOHVVDVWDWHPHQWLVVSHFL¿FDOO\LGHQWL¿HGDVDZDUUDQW\VWDWHPHQWVPDGHE\&OLPDWH0DVWHU,QFD'HODZDUHFRUSRUDWLRQ³&0´RULWVUHSUHVHQWDWLYHVUHODWLQJWR&0¶VSURGXFWVZKHWKHURUDOZULWWHQRUFRQWDLQHG LQDQ\VDOHVOLWHUDWXUHFDWDORJRUDJUHHPHQWDUHQRWH[SUHVVZDUUDQWLHVDQGGRQRWIRUPDSDUWRIWKHEDVLVRIWKHEDUJDLQEXWDUHPHUHO\&0¶VRSLQLRQRUFRPPHQGDWLRQRI&0¶VSURGXFWV(;&(37$663(&,),&$//<6(7)257+ +(5(,17+(5(,612(;35(66:$55$17<$672$1<2)&0¶6352'8&76&00$.(612:$55$17<$*$,167/$7(17'()(&76&00$.(612:$55$17<2)0(5&+$17$%,/,7<2)7+( *22'6252)7+(),71(662)7+(*22'6)25$1<3$57,&8/$5385326( &/,0$7(0$67(5,1& /,0,7('(;35(66:$55$17</,0,7$7,212)5(0(',(6$1'/,$%,/,7<)25 5(6,'(17,$/&/$66352'8&76:,7+/$%25$//2:$1&( Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Warranty 59 Tranquility ® 22 Digital (TZ) Series IOM - 60Hz HFC-410A R e v. : 1 7 J a n . , 2 0 1 3 B Revision History Page # Description 17 Jan., 13 23-25 Hot Water Generator Section Added 19 Nov., 12 Various 17 April, 12 All Content Revised First Published R AI BR I HE AT P U M P S A TO NE WATER TO IFIED TO ARI A RT S C CE NG WITH LYI MP O IR MANUFACT UR ER Date IS ST AND 3 ARD 1 -1 R O 25 6 ISO 9001:2008 Certified Quality: First & Always 7300 S.W. 44th Street Oklahoma City, OK 73179 *97B0072N11* Phone: 405-745-6000 Fax: 405-745-6058 climatemaster.com 97B0072N11 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster’s opinion or commendation of its products. The management system governing the manufacture of ClimateMaster’s products is ISO 9001:2008 certified. © ClimateMaster, Inc. 2012 60 Geothermal Heat Pump Systems ">

Download
Just a friendly reminder. You can view the document right here. But most importantly, our AI has already read it. It can explain complex things in simple terms, answer your questions in any language, and help you quickly navigate even the longest or most compilcated documents.
Advertisement
Key features
- Internal Flow Controller
- Internal Variable Speed Pump
- Expansion Tank
- Flushing Ports and Three-Way Valves
- Communicating DXM2 Board
- Horizontal and Vertical Installation
- Residential Application
- Packaged Unit
Frequently asked questions
The internal flow controller is a variable speed pump that is controlled by the DXM2 board. The pump speed is adjusted based on the difference between the entering and leaving water temperatures.
Internal variable speed pumps offer increased efficiency and reduced energy consumption compared to traditional fixed-speed pumps.
The expansion tank helps maintain a constant loop pressure, preventing fluctuations caused by the expansion and contraction of the loop due to seasonal temperature variations.