advertisement
GENERALAire
R
R ESIDENTIAL A IR T REATMENT P RODUCTS
INSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION
IS COMPLETE. LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER
This air cleaner/purifier is designed for use in systems up to 2000 CFM. For higher airflows additional units may be required. Orient the cabinet so that the air purifier is downstream of the particulate filter to prevent the carbon columns from becoming clogged with household dust. See Typical Installations below.
WARM AIR RETURN AIR
RETURN AIR
RETURN AIR
MODEL AC-3
HIGH EFFICIENCY
AIR CLEANER AND
ACTIVATED CARBON
AIR PURIFIER
FOR INSTALLATION IN THE
RETURN AIR DUCT OF ANY
FORCED AIR HEATING AND
COOLING SYSTEM
WARM AIR
GENERALAire R
FLOW THRU
SERIES HUMIDIFIER
GENERALAire R AC-3
HIGH EFFICIENCY AIR CLEANER/
ACTIVATED CARBON AIR PURIFIER
WARM AIR
COUNTER-FLOW
WARM AIR
HIGH BOY LOW BOY
INSTALLATION INSTRUCTIONS
IMPORTANT: A 26 INCH CLEARANCE MUST BE ALLOWED FOR REMOVAL OF THE MEDIA
CARRIERS FROM THE CABINET.
1. Loosen thumb screws and remove front covers.
2. Slide media frame assembly and carbon carrier from cabinet, discard packing material.
3. Turn off electricity to furnace.
4. Remove and discard existing furnace air filter.
5. Install cabinet in return air system. Be sure to follow airflow direction arrows on interior of cabinet.
Duct supports are recommended to support weight of cabinet. See typical installations.
6. Refer to media change instructions on side of media frame for installation of air cleaner media and pleat
spacers. Fill carbon media carrierwith carbon from carbon kit. Follow instructions on carrier lid.
7. Slide the media frame into the cabinet. Be sure the airflow arrow on the media frame is in the same
direction as the arrow in the cabinet. The plastic pleat spacers are always on the downstream side of
the filter media. Slide carbon media carrier into cabinet. Replace covers.
8. If a condition indicator is to be used, install on a vertical duct surface between the air cleaner/purifier and
the furnace blower.
9. Turn on furnace and check performance of all equipment.
CARE AND MAINTENANCE
The air cleaner media will normally need to be replaced at the end of the heating or cooling season. If an air cleaner condition indicator is used, change the media when the device indicates service is required. The carbon adsorption media should be changed immediately at the end of each heating and cooling season. Remove thumb screws and covers, and slide media frames out of cabinet.
Use Air Cleaner media assembly Part No. 12758 and Carbon Kit Part No. 12916.
1
Position air cleaner media frame on table with plastic pleat spacers on top. Loosen pleat spacers at each end by lifting guide pins out of holes. Carefully remove all pleat spacers.
Loosen thumb screws, remove cover and slide media carrier out of cabinet.
1
2
Lift used air cleaner media out of frame for disposal and clean wire frame.
Set media carrier on floor and remove carrier lid and foam seal.
2
3
Grasp new media pack (Part No. 12758) with right hand, about six inches from the closet end, with cardboard strips on top.
Fan pleats open with other hand underneath and start one pleat in each slot of wire media frame, working from right to left. There are thirty seven pleats and thirty seven slots.
4
When all pleats are started, slide media pack endwise into wire media frame until the holes in the cardboard strips line up with the holes in the side frames. Make sure pleat ends are even. Press pleated paper down on all areas of the wire frame.
Empty carbon from carrier into plastic trash bag. Light tapping may be necessary to loosen carbon from all tubes.
3
Set carrier upright and pour fresh carbon evenly into trough. Move carbon into unfilled tubes using brush or fingers. Gently tap carrier on surface to settle carbon in tubes.
4
5
Install the plastic pleat spacers, being careful to insert one support finger between each pleat. Press the pleat spacers down firmly to fully engage the guide pin at each end.
Replace foam seal, lid and thumb nuts.
Re-install carbon media carrier in air purifier cabinet.
5
6
Slide the assembled media frame into the air cleaner cabinet. Be sure the airflow arrow on the media frame is in the same direction as the arrow in the cabinet. The plastic pleat spacers are always on the downstream side of the filter media. Attach outer cover and tighten thumb screws.
GENERALAire
R
R ESIDENTIAL A IR T REATMENT P RODUCTS
INSTALLATEUR : VEUILLEZ REMPLIR ET POSTER LA CARTE DE GARANTIE UNE FOIS L'INSTALLATION
TERMINÉE. LAISSER LES DIRECTIVES D'INSTALLATION AU PROPRIÉTAIRE DE LA MAISON.
Ce purificateur d'air est conçu pour l'usage avec des systèmes de capacités allant jusqu'à 2000 p³/min. Pour des débits d'air plus importants, des unités supplémentaires pourraient être nécessaires. Lorsque le purificateur d'air au charbon activé est utilisé avec un purificateur d'air à filtre de particules et à haut rendement, monter le purificateur d'air en aval du filtre de particules afin d'éviter que les colonnes de charbon se bouchent de poussière.
Voir l'installation typique ci-dessous.
REPRISE AIR
REPRISE AIR
AIR CHAUD REPRISE AIR
PURIFICATEUR D'AIR
À HAUT RENDEMENT
ACTIVATED CARBON
AIR PURIFIER
MODÈLE AC-3
POUR INSTALLATION DANS LE
CONDUIT DE RETOUR D'AIR DE
TOUT SYSTÈME DE
CLIMATISATION À AIR PULSÉ
AIR CHAUD
GENERALAire
R
HUMIDIFICATEUR DE LA SÉRIE
CIRCULATION DIRECTE
AIR CHAUD
GENERALAire R
AC-3
HAUT RENDEMENT FILTRE À AIR/
PURIFICATEUR D'AIR AU CHARBON ACTIF
FLUX VERS LE HAUT FLUX VERS LE BAS
AIR CHAUD
SOUS-SOL
DIRECTIVES D'INSTALLATION
IMPORTANT : UN ESPACE LIBRE DE 26 po DOIT ÊTRE PRÉVU POUR LE RETRAIT DES
SUPPORTS DE MÉDIA DU BOÎTIER
1. Desserrer les vis ailées et retirer les couvercles avant.
2. Glisser l'ensemble cadre de média et le support de charbon du boîtier ; jeter l'emballage.
3. Couper l'alimentation électrique à la fournaise.
4. Retirer et jeter le filtre d'air de la fournaise actuellement utilisé.
5. Installer le boîtier dans le système de reprise d'air. S'assurer de respecter les flèches de direction de flux d'air à l'intérieur du boîtier. Les supports de conduit sont conseillés afin de soutenir le poids du boîtier.
Voir les installations typiques.
6. Consulter les instructions de remplacement de média sur le bord du cadre de média pour l'installation du média de purificateur d'air et des espaceurs de plis. Remplir le support du média avec du charbon de la trousse de charbon. Suivre les instructions sur le couvercle du support.
7. Glisser le cadre de média dans le boîtier. S'assurer que la flèche de débit d'air sur le cadre du média est orientée dans le même sens que la flèche dans le boîtier. Les espaceurs de pli en plastique sont toujours du côté en aval du média filtrant. Glisser le support de média dans le boîtier. Remettre les couvercles.
8. Si l'emploi d'un indicateur de condition est prévue, installer sur une surface de conduit vertical entre le purificateur d'air et le souffleur de la fournaise.
9. Mettre la fournaise en marche et vérifier le fonctionnement de tout le matériel.
SOINS ET ENTRETIEN
Il faudra normalement changer le média de purificateur d'air à la fin de la saison de chauffage ou de refroidissement. Si un indicateur de condition est utilisé, changer le média lorsque le dispositif indique que l'entretien est nécessaire. Le média d'adsorption au charbon devrait être changé immédiatement à la fin de chaque saison de chauffage et de refroidissement. Retirer les vis ailées et les couvercles, et glisser les cadres de média hors du boîtier. Utiliser l'ensemble média de purificateur d'air (pièce no 12758) et la trousse de charbon (pièce no 12916).
1
Positionner le cadre de média du purificateur d'air sur la table avec les espaceurs de pli en plastique en haut.
Desserrer les espaceurs de pli à chaque extrémité en soulevant les tenons de guidage de leurs trous. Retirer avec soin tous les espaceurs de pli.
Desserrer les vis ailées, retirer le couvercle et glisser le support du média hors du boîtier.
1
2
Retirer le média de purificateur usagé du cadre pour élimination et nettoyer le cadre en fil.
Poser le support de média par terre et retirer le couvercle du support ainsi que le joint en plastique.
2
3
Saisir un nouveau bloc média (Pièce No
12758) dans la main droite, à environ 6 pouces du bord le plus proche, avec les bandes en carton en haut. Avec l'autre main en dessous, ouvrez les plis et insérez un pli dans chaque fente de le cadre en fil du média, travaillant de droite à gauche. Il y a trente-sept plis et trente-sept fentes.
4
Lorsque tous les plis sont amorcés, glisser le bloc média en long dans le cadre de média en fil jusqu'à ce que les trous dans les bandes en carton s'alignent avec les trous dans les cadres latéraux. S'assurer que les bouts des plis sont uniformes.
Appuyer le papier plissé partout contre le cadre en fil.
5
Installer les espaceurs de pli en plastique, en prenant bien soin d'insérer une patte de soutien dans chaque pli. Appuyer fermement sur les espaceurs de plis afin d'engager entièrement les tenons de guidage à chaque extrémité.
Vider le charbon du support dans un sac poubelle. Il peut être nécessaire de taper légèrement afin de déloger le charbon de tous les tubes.
3
Poser le support à la verticale et verser du charbon frais de façon uniforme dans la goulotte. Faire entrer le charbon dans les tubes non remplis à l'aide d'une brosse ou des doigts Taper doucement sur la surface du support afin que le charbon se dépose dans les tubes.
4
Remplacer le joint en mousse, le couvercle et les écrous à ailettes.
Réinstaller le support du média au charbon dans le boîtier du purificateur d'air.
5
6
Glisser le cadre de média monté dans le boîtier du purificateur d'air. S'assurer que la flèche de débit d'air sur le cadre du média est orientée dans le même sens que la flèche dans le boîtier. Les espaceurs de pli en plastique sont toujours du côté en aval du média filtrant. Attacher le couvercle extérieur et serrer les vis ailées.
12908 ADSORBER CARRIER ASSEMBLY
P-109 SCREW
12910 CARRIER END CLOSED
12357 TINNERMAN NUT
12913 ADSORBER TUBE
12914 SIDE FRAME
12909 CARRIER END OPEN
12599 STUD
12911 CARRIER END SEAL
12912 CARRIER END LID
12408 THUMBNUT
12916 ACTIVATED CARBON KIT
12757 PLEAT SPACER
12758 AIR CLEANER
MEDIA ASS'Y
12749 MEDIA FRAME ASSEMBLY
12754 SIDE FRAME ASSEMBLY
12756 STUD RECEIVER
P-178 SCREW
12751 SEPARATOR ASSEMBLY
FORM NO. 13010 Rev. C
PARTS LIST
13001 AIR CLEANER / PURIFIER
CABINET
12762 FILTER PAPER END
SEAL KIT
13006 COVER ASSEMBLY
(PARTICULATE)
13008 COVER ASSEMBLY (CARBON)
P-186 PUSH NUT
12829 WASHER
12748 THUMB SCREW
FILL OUT AND MAIL THIS
WARRANTY CARD AND
LITERATURE REQUEST FORM
A
IR
C
LEANERS AND
A
IR
P
URIFIERS
H
UMIDIFIERS
D
IGITAL
H
UMIDITY
G
AGE
A
IR
F
ILTER
G
AGE
F
UEL
O
IL
F
ILTERS AND
A
CCESSORIES
LIMITED WARRANTY
This air cleaner/purifier, if properly registered by the return of the attached warranty registration card to the manufacturer, is warranted to the consumer against defects in materials and workmanship for a period of one year from the date of installation. The air cleaner and carbon adsorption medias are not covered by this limited warranty or any other warranties. Any other defective parts will be repaired without charge except for removal, reinstallation and transportation costs. To obtain repair service under this limited warranty, the consumer must send the defective part or the complete unit to the manufacturer.
THERE ARE NO EXPRESS WARRANTIES COVERING THIS AIR CLEANER/PURIFIER OTHER THAN AS SET FORTH ABOVE, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR. THE
MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN
THIS LIMITED WARRANTY. THE MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow either limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation may not apply to you.
Any questions pertaining to this limited warranty should be addressed to the manufacturer. (U.S.A.: The manufacturer has elected not to make available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.)
GENERAL FILTERS, INC. 43800 GRAND RIVER AVE. NOVI, MICHIGAN 48375-1115 WWW.GENERALAIRE.COM
CANADIAN GENERAL FILTERS, LTD. 39 CROCKFORD BLVD. SCARBOROUGH, ONTARIO M1R3B7 WWW.CGFPRODUCTS.COM
ABOUT THE HIGH EFFICIENCY AIR CLEANER & ACTIVATED CARBON AIR PURIFIER
Your High Efficiency Air Cleaner & Activated Carbon Air Purifier is an investment in comfort and protection for your family for two reasons. The Air
Cleaner is much more efficient than ordinary furnace air filters, and you may expect benefits if you suffer from allergies caused by pollen, dust and other airborne allergens. The High Efficiency Air Cleaner is not a cure for allergy problems but you may discover that closing the house during the pollen season, and operating the heating and cooling system blower continuously, will provide substantial relief.
The activated carbon, used in the Air Purifier has the capacity to adsorb most chemical vapors. In operation, eighteen columns of activated carbon are positioned in the return airflow of your heating and cooling system, just downstream of the Air Cleaner. The carbon columns are designed to intercept and adsorb vapors and gases that particulate filters fail to remove. The Air Purifier is a bypass adsorber with spacing between the carbon columns to minimize resistance to airflow and not interfere with the normal operation of the heating and cooling system. The carbon air purifier will not remove all gaseous contaminants from the air in one pass. Through the normal recirculation that occurs in a residential heating system, however, a significant reduction in odor causing gases and vapors can be expected.
The Air Cleaner/Purifier has no electrical components and therefore requires minimum service and does not generate ozone. The air cleaner media will normally need to be replaced at the end of the heating or cooling season. If an air cleaner condition indicator is used, change the media when the device indicates service is required. The carbon adsorption media should be changed immediately at the end of each heating and cooling season.
Litho in U.S.A.
12908 ENSEMBLE DU SUPPORT D'ADSORBEUR
P-109 VIS
12910 BOUT DU SUPPORT -FERMÉ
12357 ÉCROU TINNERMAN
12913 TUBE D'ADSORBEUR
12914 CADRE LATÉRAL
12909 BOUT DU SUPPORT - OUVERT
12599 MONTANT
12911 JOINT DU BOUT DU SUPPORT
12912 COUVERCLE DU BOUT DU SUPPORT
12408 ÉCROU À AILETTES
12916 TROUSSE DE CHARBON ACTIVÉ
12757 ESPACEUR DE PLI
12758 ENSEMBLE MÉDIA DE
PURIFICATEUR D'AIR
12749 ENSEMBLE CADRE DE MÉDIA
12754 ENSEMBLE CADRE LATÉRAL
12756 AGRAFE POUR MONTANT
P-178 VIS
12751 ENSEMBLE SÉPARATEUR
FORMULAIRE N° 13010 Révision C
LISTE DES PIÈCES
13001 BOÎTIER DU PURIFICATEUR
D'AIR
12762 TROUSSE D'EMBOUT EN
PAPIER FILTRE
13006 ENSEMBLE COUVERCLE
(SUBSTANCE PARTICULAIRE)
P-186 ÉCROU CAPUCHON
12829 RONDELLE
12748 VIS AILÉE
À PROPOS DU PURIFICATEUR D'AIR À HAUT RENDEMENT
ET PURIFICATEURS D'AIR AU CHARBON ACTIF
Votre purificateur d'air à haut rendement au charbon activé est un investissement dans le confort et la protection de votre famille pour deux raisons. Le purificateur d'air est bien plus efficace que les filtres d'air pour fournaises ordinaires et vous pouvez vous attendre à en bénéficier si vous souffrez d'allergies au pollen, à la poussière ou autres. Le purificateur d'air à haut rendement n'est pas un remède pour les allergies, mais vous pourriez découvrir que le fait de fermer la maison pendant la saison des pollens et de faire fonctionner le souffleur du système de climatisation de façon continue peut offrir un soulagement sensible.
Le charbon activé utilisé dans le purificateur d'air a la capacité d'adsorber la plupart des vapeurs chimiques. Lors du fonctionnement dix-huit colonnes de charbon activé sont positionnées dans le retour d'air de votre système de climatisation, juste en aval du purificateur d'air. Les colonnes de charbon sont conçues pour intercepter et adsorber divers gaz et vapeurs que les filtres de particules n'arrivent pas enlever. Le purificateur d'air est un adsorbeur de dérivation avec de l'espace libre entre les colonnes de charbon pour minimiser la résistance au débit d'air et pour ne pas entraver le fonctionnement normal du système de climatisation. Le purificateur d'air au charbon n'enlèvera pas tous les contaminants gazeux dans l'air dans un cycle. On peut s'attendre toutefois, grâce à la recirculation d'air produite dans un système de chauffage résidentiel, à une réduction sensible des gaz et des vapeurs qui produisent des odeurs.
Le purificateur d'air ne comporte aucun composant électrique et, par conséquent, n'exige qu'un entretien minimal ; et ne crée pas d'ozone. Il faudra normalement changer le média de purificateur d'air à la fin de la saison de chauffage ou de refroidissement. Si un indicateur de condition est utilisé, changer le média lorsque le dispositif indique que l'entretien est nécessaire. Le média d'adsorption au charbon devrait être changé immédiatement à la fin de chaque saison de chauffage et de refroidissement.
GARANTIE LIMITÉE
Si ce purificateur d'air est enregistré adéquatement en retournant la fiche d'inscription de garantie ci-jointe au fabricant, il est garanti au consommateur contre les défauts de fabrication ou de matériaux pour une période d'un an à compter de la date d'installation. Le purificateur d'air et les médias d'adsorption au charbon ne sont pas couverts par la présente garantie limitée ni par toute autre garantie. Toute autre pièce défectueuse sera réparée sans frais, hormis les coûts de désinstallation, de réinstallation et de transport. Pour obtenir des services d'entretien ou de réparation en vertue de cette garantie limitée, le consommateur doit envoyer la pièce défectueuse ou l'appareil complet au fabricant.
IL N'Y A AUCUNE GARANTIE EXPRESSE COUVRANT CE PURIFICATEUR D'AIR EN DEHORS DES DISPOSITIONS STIPULÉES CI-DESSUS, LES
GARANTIES TACITES QUANT À LA QUALITÉ MARCHANDE ET À L'APTITUDE À UN EMPLOI PARTICULIER SONT LIMITÉES À UNE DURÉE D'UN
AN. LE FABRICANT NE PEUT ÊTRE TENU RESPONSABLE POUR L'INSTALLATION OU L'UTILISATION DE CE PRODUIT, SAUF DE LA MANIÈRE
INDIQUÉE DANS LA PRÉSENTE GARANTIE LIMITÉE. LE FABRICANT NE PEUT EN AUCUN CAS ÊTRE TENU RESPONSABLE POUR DES
DOMMAGES ACCESSOIRES OU INDIRECTS.
Cette garantie limitée vous donne des droits légaux spécifiques et vous pouvez jouir d'autres droits qui varient d'une juridiction à l'autre. Certaines juridictions ne permettent pas de limites sur les garanties implicites ou d'exclusions pour les dommages accessoires ou indirects; les exclusions sus mentionnées peuvent donc ne pas s'appliquer dans votre cas.
Toute question relative à cette garantie limitée doit être soumise au fabriquant. (É.-U. : Le fabricant à choisi de ne pas divulguer les termes de l'accord spécifiés dans le " Magnuson-Moss Waranty Act ".)
GENERAL FILTERS, INC. 43800 GRAND RIVER AVE. NOVI, MICHIGAN 48375-1115 WWW.GENERALAIRE.COM
CANADIAN GENERAL FILTERS, LTD. 39 CROCKFORD BLVD. SCARBOROUGH, ONTARIO M1R3B7 WWW.CGFPRODUCTS.COM
Lithographie aux É.-U.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project