RDS 40WE Wide Energy Range Meter

RDS 40WE Wide Energy Range Meter
ADVANCED TECHNOLOGY FOR A SAFER WORLD
RDS 40WE
Wide Energy Survey Meter
The RDS-40WE is a Digital Handheld Dose
Rate Meter designed for use by personnel
who may be exposed to gamma and/or Xray radiation in their work. RDS-40WE
provides either sequential or fixed dose rate
alarming system (values are programmable
with the CSW configuration software via
IrDA link) and the ability to store dose rate
events into the histogram memory of the
meter. The easy to use RDS-CSW
software is required for downloading the
data into a PC via IrDA port.
The compact and durable RDS-40WE is a
microprocessor controlled instrument that
employs a single push button user
interface. The menu structure is very
straightforward and easy to understand with
messages and information displayed on the
digital LCD meter face. The six-digit display
also shows the dose rate and numerous
other essential notifications. Different alarm
situations are indicated by a combination of
audio-visual effects on the LCD and a
buzzer (dose rate, dose, low battery, defect,
dose rate overflow).
FEATURES
• Wide Energy range 16.3 keV - 3
•
•
•
•
•
•
•
•
•
•
•
•
MeV
measurement according to H*(10)
dose measurement indication
high battery life time (>1 year)
*compliant to IEC 60846
dose rate follow-up by audible signal
with frequency
proportional to dose rate
visual and audible alarm: user
selectable for dose and dose rate
over the whole measurement range
histogram capability of up to 480
dose rate values with user
selectable logging interval
backlit display with six large digits
display in either µSv/h or in mrem/h
built-in self diagnostics
enclosure class IP67
* see Radiological Characteristics
LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.LaurusSystems.com
TECHNICAL SPECIFICATIONS:
Radiological Characteristics
•
•
•
•
radiation detected: gamma and x-rays, 16.3 keV (±30o) 24keV... 3 MeV±45o
detector: one energy-compensated GM tube. Energy response according to ambient
dose equivalent H*(10)
measurement range: effective dose rate 0. 1 µSv/h – 50 mSv/h or 10 µrem/h – 5 rem/h,
dose 0.1 µSv – 1 Sv or 10 µrem – 100 rem
alarm levels: adjustable alarm levels for dose rate and accumulated dose
calibration accuracy: ± 5 % of the reading in 137Cs exposure, at 3 mSv/h (300 mrem), +20°C (68°F)
dose rate linearity: ±18% in the whole measurement range
response to radiation energy -29 % to +67 % over the range of 16.3 keV to 3 MeV
Functional Characteristics
•
•
•
•
•
visual and audible alarm: user settable for dose and dose rate
histogram capability of up to 480 points with user settable logging interval 10s ... 14 400s
backlit display with six large digits
built-in self diagnostics
IrDA link to PC
Electrical Characteristics
•
•
•
power supply: 2 alkaline batteries IEC LR6/AA size (recommended)
battery life time: at least 1000 hours at normal background with alkaline cells
battery alarm: two-step alarm for low battery voltage
Mechanical Characteristics
•
•
•
•
•
rugged plastic case
resistant against RF interferences
enclosure class: IP67
dimensions: 78 x 126 x 57 mm
weight: 294 g without batteries, 342 g with batteries
Environmental Characteristics
Temperature range:
•
-25...+55°C operational (-13°F to 131°F)
•
-40...+70°C storage (-40... 158°F)
Accessories
•
•
•
•
•
•
Detector under energy filter
CSW configuration software
wrist strap