MODEL: KWYPD Plug-in Signal Conditioners K-UNIT [3] OUTPUT 1 PULSE ISOLATOR
![MODEL: KWYPD Plug-in Signal Conditioners K-UNIT [3] OUTPUT 1 PULSE ISOLATOR MODEL: KWYPD Plug-in Signal Conditioners K-UNIT [3] OUTPUT 1 PULSE ISOLATOR](http://s1.manualzz.com/store/data/010696133_1-5d293da820aa5a3061c12ab5e8f9817c-768x994.png)
MODEL: KWYPD Plug-in Signal Conditioners K-UNIT PULSE ISOLATOR (isolated two outputs; built-in excitation) Functions & Features • Galvanically isolating pulse rate signals • Input frequency = output frequency • Various outputs (relay, open collector and voltage pulses) • Excitation • Isolation up to 2000 V AC • High-density mounting Typical Applications • Isolating field pulse signals in order to reduce noises • Changing e.g. dry contact signal to e.g. 5 V signals [3] OUTPUT 1 A1: Open collector (max. frequency 100 kHz) A2: Open collector (max. frequency 10 Hz) M1: 5 V pulse (max. frequency 100 kHz) M2: 5 V pulse (max. frequency 10 Hz) N1: 12 V pulse (max. frequency 100 kHz) N2: 12 V pulse (max. frequency 10 Hz) H: Relay contact (max. frequency 0.5 Hz) [4] OUTPUT 2 Same range availability as Output 1 (Choose a combination of output 1 and 2 with same max. frequency limit. Output logic of open collector is reversed when open collector and others are mixed.) [5] OUTPUT PULSE WIDTH 50 (1.97) 1: Equal to the input 2: One-shot output (≤ 30 ms; std. pulse width 5 ms) (Specify when optional pulse width is required.) (10 ms for relay contact pulse) 3: One-shot output (≥ 30 ms; std. pulse width 50 ms) (Specify when optional pulse width is required.) 80 (3.15) K-UNIT 132 (5.20) [6] OUTPUT LOGIC mm (inch) N: The same as the input R: Inverted MODEL: KWYPD–[1][2][3][4][5][6]–[7] [7] POWER INPUT ORDERING INFORMATION • Code number: KWYPD-[1][2][3][4][5][6]-[7] Specify a code from below for each [1] through [7]. (e.g. KWYPD-D4A2M23N-B) • Frequency range (e.g. 0 – 5 Hz) • Output pulse width (e.g. 75 msec.) Use Ordering Information Sheet (No. ESU-2276). Default setting will be used if not otherwise specified. [1] INPUT A: Dry contact B: DC voltage pulse (Specify sensitivity) C: 5 V pulse (sensitivity 2 V) D: 12 V/24 V pulse (sensitivity 5 V) H: Two-wire current pulse [2] EXCITATION 1: 5 V DC / 80 mA 4: 12 V DC / 40 mA http://www.m-system.co.jp/ AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Housing material: Flame-resistant resin (black) Isolation: Input to output 1 to output 2 to power Input pulse sensing: DC coupled Input filter: Provided for 10 Hz or lower output frequency (time constant approx. 1 msec.) KWYPD SPECIFICATIONS ES-3577 Rev.10 Page 1/5 MODEL: KWYPD INPUT SPECIFICATIONS Excitation: Shortcircuit protection; approx. 150 mA at shortcircuit • Dry Contact Max. frequency: 100 kHz Pulse width time requirement: 5 μsec. min. (10 ms for 0 – 10 Hz or lower frequency) Sensing: 10 V DC @ 2.5 mA ON/OFF level: ≥ 5.5 kΩ /5.5 V for OFF ≤ 1.8 kΩ /4.5 V for ON • Voltage Pulse: Specify DC offset and amplitude. Max. frequency: 100 kHz Pulse width time requirement: 5 μsec. min. (10 ms for 0 – 10 Hz or lower frequency) Waveform: Square or sine Input impedance: 10 kΩ min. Input amplitude: 2 – 50 Vp-p Offset: 2 – 10 V Max. voltage between input terminals: 50 V • 5V, 12V, 24V Pulse Waveform: Square or sine Input impedance: 10 kΩ min. Detecting level INPUT 5 V PULSE 12 V / 24 V PULSE VH ≥ 2.25 V ≥ 5.25 V VL ≤ 1.75 V ≤ 4.75 V • Two-wire Current Pulse Max. frequency: 100 kHz Pulse width time requirement: 5 μsec. min. (10 ms for 0 – 10 Hz or lower frequency) Input resistance: Receiving resistor 220 Ω Maximum current: ± 50 mA Hi/Lo level: ≤ 5 mA for Lo, ≥ 15 mA for Hi Volts 50V max. Relay life: 2 × 107 cycles (mechanical) 7 × 106 cycles (electrical) OUTPUT PULSE WIDTH •Equal to the Input: No pulse width conversion (difference between input and output within ±10 μsec.) • One-shot Output: Constant pulse width Output Frequency (Hz) = 500 / (Output Pulse Width (msec.)) Adjustable pulse width Pulse width max. 30 msec. (code 2): 1 – 30 msec. adjustable (standard 5 msec. ±20 %) for 'Output' code other than 'H' 10 – 30 msec. adjustable (standard 10 msec. ±20 %) for 'Output' code 'H' Pulse width min. 30 msec. (code 3): 30 msec. – 1 sec. adjustable (standard 50 msec. ±20 %) INSTALLATION Power input AC: Operational voltage range: rating ±10 %, 50/60 ± 2 Hz, approx. 2.5 VA DC: Operational voltage range: rating ±10 %, ripple 10 %p-p max., approx. 2 W (80 mA at 24 V) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output 1 or output 2 to power to ground) 1000 V AC @1 minute (output 1 to output 2) Amplitude Vinp-p DC Offset t OUTPUT SPECIFICATIONS • Open Collector: 50 V DC @ 50 mA (resistive load) Maximum frequency: 100 kHz with load resistance ≤ 1 kΩ Saturation voltage: 0.5 V DC • Voltage Pulse: Rating (5 or 12 V) ± 10 % Maximum frequency: 100 kHz Load resistance: 1.5 kΩ min. for 5 V, 3 kΩ min. for 12 V • Relay Contact: 120 V AC or 30 V DC @ 200 mA (resistive load) Maximum frequency: 0.5 Hz http://www.m-system.co.jp/ KWYPD SPECIFICATIONS ES-3577 Rev.10 Page 2/5 MODEL: KWYPD EXTERNAL VIEW Excitation Adj. Sensitivity Adj. Pulse Width Adj. OUTPUT LOGIC ■When an Open Collector is not Mixed with the Another Output Type: INPUT TYPE PULSE LOGIC Voltage Pulse Input 2-wire Current Pulse Input ON current (H) OFF current (L) Non Inverted INPUT VOLTAGE PULSE OUTPUT OPEN COLLECTOR or RELAY CONTACT H H OFF L L ON H H OFF L L ON OFF H OFF Inverted Non Inverted Dry Contact Input ON L ON OFF H OFF ON L ON Inverted The pulse width in one-shot means the bold lined section of a pulse waveform. ■When an Open Collector is Mixed with Another Output Type: When combinations "a voltage pulse and an open collector" or "a relay contact and an open collecctor" are chosen, be aware that the logic of the output 2 is inverted. [example 1] Input : voltage pulse Output 1: voltage pulse Output 2: open collector PULSE LOGIC INPUT (voltage pulse) OUTPUT 1 (voltage pulse) OUTPUT 2 (open collector) H H L L OFF ON H H OFF L L ON Non Inverted Inverted [example 2] Input : voltage pulse Output 1: relay contact Output 2: open collector PULSE LOGIC INPUT (voltage pulse) OUTPUT 1 (relay contact) OUTPUT 2 (open collector) H OFF L ON OFF ON H OFF OFF L ON ON Non Inverted Inverted [example 3] Input : open collector Output 1: open collector Output 2: voltage pulse PULSE LOGIC INPUT (open collector) OUTPUT 1 (open collector) OUTPUT 2 (voltage pulse) OFF OFF ON ON H L OFF OFF H ON ON L Non Inverted Inverted http://www.m-system.co.jp/ KWYPD SPECIFICATIONS ES-3577 Rev.10 Page 3/5 MODEL: KWYPD DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) DIN RAIL 35mm wide 8 7 6 5 80 (3.15) 80 (3.15) 35.4 (1.39) 4 2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 9 10 11 11–M3.5 SCREW 50 (1.97) 3 1 2 40 (1.57) 103 (4.06) [3.3 (.13)] 132 (5.20) 50 (1.97) • When mounting, no extra space is needed between units. SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM SENSITIVITY PULSE WIDTH Waveform Shaper One-shot* Isolation + 5 INPUT Output Driver 1 + OUTPUT 1 2 – – 6 SENSOR EXCITATION Excitation Supply + 4 Output Driver 3 10 + OUTPUT 2 11 – EXCITATION 9 7 U(+) POWER 8 V(–) Base Socket *Disregard one-shot circuit for output pulse width code "1" Input Connection Examples ■Dry Contact Output Connection Examples ■2-Wire Current Pulse •Built-in Excitation +10V 4kΩ PWR + – – + – 5 2-WIRE PICK-UP 6 5 ■Open Collector 220Ω 6 Vsns ■Voltage Pulse 1 + + 1 + + 2 – – 2 – – Vsns + 4 4 ■Relay Contact •AC Powered ■Voltage Pulse •External DC Supply Relay or Counter Coil 1 PWR + – – + 5 10kΩ 2-WIRE PICK-UP 6 Vsns 4 – + 5 DC SUPPLY 6 + – 4 220Ω 2 Vsns LOAD •DC Powered Relay or Counter Coil 1 2 http://www.m-system.co.jp/ Varistor or Spark Quenching Circuit LOAD KWYPD SPECIFICATIONS Spark Quenching Diode ES-3577 Rev.10 Page 4/5 MODEL: KWYPD Specifications are subject to change without notice. http://www.m-system.co.jp/ KWYPD SPECIFICATIONS ES-3577 Rev.10 Page 5/5
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download PDF
advertisement