FX-Family The world’s favorite micro PLCs MELSEC PLC
FX-Family
MELSEC PLC
The world’s favorite
micro PLCs
10 Million FX PLCs Worldwide /// Over 30 Years Experience ///
Expanded Micro PLC Control /// Networking Solutions ///
Analog Solutions /// Positioning Solutions ///
Global leader /// Global leader /// Global leader /// Global leader /// Global
Global Leader
The MELSEC FX3U/FX3UC series are the third generation on programmable controllers of the Mitsubushi Electric FX family.
They offer improved network capability and solutions for positioning tasks.
10 Million FX
The FX Family of PLCs is the PLC of choice
across the world, industries and applications.
Mitsubishi Electric has always worked
closely with its customers to design the
PLC that they want for their applications.
The manufacturing and use of 10 million
FX CPUs is a demonstration that this
close working relationship has delivered
quality, reliability and the product that customers want.
Number 1 in
the world
Mitsubishi Electric was shown to be the
largest volume producer of PLCs in the
world following the 2004 Worldwide
PLC survey by the respected American
automation research company ARC.
Over 30 Years
The FX Family of PLCs has been an important part of control engineering for over
30 years. Throughout its history, the product has evolved from the original F Series
into today's current FX3G series.
The FX Family has proven to be highly reliable and it consistently improves its compatibility with previous PLC generations.
2
ARC is protected by ARC Advisory Group copyright 2004
/// Contents /// Contents /// Contents /// Contents /// Contents /// Contents
Contents
What makes a world leading PLC?
Range overview
FX3U/FX3UC, a new concept in PLCs
4-5
6
7-9
FX3G, an automation standard
10
FX1N, the modular micro
11
FX1S, micro control
12
Programming and software
13
Networking
14
Analog solutions
15
Positioning solutions
16
Displays solutions
17
Applications
18
Section 2: Technical Informations
3
World leading PLCs /// World leading PLCs /// World leading PLCs /// World l
What makes
a world leading PLC range?
Adapter or "ADP" units are used
on the left hand side of the
main PLC unit.
Memory cassette port is located under the removable front
cover.
Global use
Wide range power supply means your
FX solution will work all over the world.
International
acceptance
Shipping approvals such as Lloyds, German
Lloyds, ABS, RINA, Det Norse Vetaritas, for
example plus CE and E1 compliance for
Low Voltage and EMC directives as well as
manufacturing to Automotive industry
quality levels, make the FX Family PLCs
products to trust.
The standard RS422 Mini-DIN
programming port can also be
used for HMI connection.
Optional communication boards
are available in USB, RS232C,
RS422 and RS485 formats.
Flexible design
The FX Family is designed so that the main
PLC CPU acts as a platform to which you
can add and customize the special functions you need – making every FX your personal PLC.
4
The RUN/STOP switch has
become a familiar feature with
all FX Family PLCs.
eading PLCs /// World leading PLCs /// World leading PLCs /// World leading
Main base unit where CPU,
I/O and power supply are
contained in a single unit.
All FX PLC units can be mounted
on a DIN rail or directly mounted
with screw fixings.
Easy
Programming
The FX Family incorporates an easy programming concept where several complex
tasks can be reduced to a single instruction.
Fast and reliable
FX PLCs continually push the limits of
high speed operation to process your
applications more effectively and accurately.
Simple ribbon connection links each
unit together.
Special function blocks can
be added to the right hand
communications bus of
the PLC.
Bright LED lamps indicate I/O
and power status.
Compatibility
The FX Family of PLCs continues to raise
the level of backward compatibility with
many existing FX PLC programs being
transferable. And in later models, sharing
common peripherals and special function
blocks means even greater protection for
your investment in both FX and the
machine or process being controlled.
5
The power to perform /// The power to perform /// The power to perform /
The power to perform
/FX3UC
Ultra high speed, maximum
performance and a simplified
design concept make this the
ultimate micro PLC.
Performance
FX3G
Advanced control, multiple
communication possibilities
and a wide range of options
make this PLC an industry
leader.
FX1N
This powerful micro brings
the flexibility of the modular
PLC design concept but, with
the ease of use typical of
FX Family PLCs.
FX1S
A compact micro controller
for simple applications, supported by a strong communications capability.
I/O
The FX Family of PLCs builds on previous performance and capability, ensuring you have a comprehensive range of control and automation
options to choose from.
Model
FX1S
FX1N
FX3G
FX3U
FX3UC
Power supply
100–240 V AC,
24 V DC
100–240 V AC,
12-24 V DC
100–240 V AC
100–240 V AC,
24 V DC
24 V DC
Maximum I/O
30
(34 optional)
128
(132 optional)
256**
384*
384*
Digital I/O
Relay/
Transistor
Relay /
Transistor
Relay /
Transistor
Relay /
Transistor
Transistor
Cycle period/
logical
instruction
0.55 µs
0.55 µs
0.21 µs or 0.42 µs
0.065 µs
0.065 µs
PLC program
memory
2 k steps
8 k steps
32 k steps
64 k steps
64 k steps
Summary table of FX PLCs
Note * : When networked with CC-Link or AS-Interface (Discrete I/O, maximum 256)
Note **: When networked with CC-Link or AS-Interface (Discrete I/O, maximum 128)
A solution for
every application
Micro PLCs have opened up a world of
opportunities in Industrial Automation due
to their small size and low cost. Now many
applications benefit from enhanced performance, easier manufacturing, maintenance and greater reliability.
The FX Family has been a part of this revolution for over 30 years and has developed
and redeveloped a range of products to
suit most applications. The FX Family consists of four main ranges which are distinct
and independent but compatible.
Depending on your application and control
needs, you can choose from; the simple
FX1S CPU, the modular FX1N range, the
powerful FX3U and now the current and
dynamic FX3G.
With the FX Family there really is a solution
to most applications.
6
/// FX3U a perfect PLC concept /// FX3U a perfect PLC concept /// FX3U
The FX3U has an enhanced communications bus that automatically switches into
high speed mode for communication with
new FX3U expansion modules.
Full compatibility is still available with
FX2N and FX0N expansion blocks, and
when these are configured the FX3U automatically reduces the bus speed to suit.
This means greater support for existing
installed systems as well as delivering high
performance and greater response with
new installations.
Adapters add
flexibility
FX3U a perfect
PLC concept
A major design enhancement of FX3U is
the new adapter expansion bus on the left
hand side of the FX3U CPU. Through this
bus users can add additional analog and
temperature units as well as multiple communications and positioning blocks.
The FX3U CPU brings a combination of
greater flexibility and increased performance to the FX Family.
New high
speed bus
The FX3U design has increased the opportunity to configure the PLC directly for your
needs.
Following the standard FX Family configuration, the FX3U CPU can be expanded to
the right hand side using a wide range of
options. These include input and output
blocks as well as special function blocks
such as analog, pulse train and network
communication units.
FX3U has a unique new system of directly
programmable adapters.
However, the major benefit for the user is
that the analog and positioning adapter
units no longer require the use of the traditional To/From instruction to configure and
operate.
All control is through direct access data
registers and setting bits. This means
quicker set-up, easier use, and above all
much higher processing speeds.
The FX3U can use new FX3U blocks as well as
standard FX2N and FX0N expansion blocks..
7
FX3U/FX3UC a perfect PLC concept /// FX3U/FX3UC a perfect PLC concept /// F
FX3U/FX3UC. More power.
More performance.
FX3U/FX3UC Base Unit
Expansion I/O
Maximum
Network master
Remote I/O
256 I/O
Remote I/O
Remote I/O
Remote network stations
System Maximum
384 I/O
Maximum
256 I/O
FX3U/FX3UC provides additional I/O and networking capacity.
FAST
Basic
instruction
FX3U/FX3UC provides increased performance
in all areas.
Note: 4.5 times increase in speed is measured under the following conditions: program capacity=16 k step, with an I/O
usage of 144 points. Program scan time is then; FX3U/FX3UC:
4.6 ms and FX2N: 21.0 ms, an increase in processing speed of
4.56 times.
With enhanced networking functions, the
FX3U/FX3UC requires an increased input/
output (I/O) range. FX3U/FX3UC can support systems with combined local I/O and
networked I/O up to a total of 384 I/O
points. For users, this means increased system control and added possibilities for
advanced networks.
With a larger program memory comes the
need for more operational devices such as
timers, state flags, auxiliary relays and data
registers. The FX3U/FX3UC has increased
capacity in all of these major areas making
program construction easier. Data register
capacity has increased by a factor of
5 reflecting the needs of users who have an
increased requirement to log operation
information against products or batches of
products being manufactured.
In addition FX3U/FX3UC also fully supports Profibus/DP as well as Ethernet using
TCP and UDP protocols.
3072 points
4096 points
1000 points
512 points
256 points
40768* points
Data Registers (D)
8000 points
Up to 4.5
times faster
This means the PC MIX value has been
greatly improved with basic instructions
now being processed in 0.065 µsec.
For users this means quicker program
response and more accurate process performance as inputs, outputs and actions
are processed and monitored more times
per second.
7680 points
Auxilliary Relay (M)
Timers (T)
5 times more
data storage
FAST
Applied
instruction (MOV)
State Flags (S)
Increased I/O
capacity
*Includes R Registers
FX3U/FX3UC offers increased resources as
well as increased performance.
8 times more
memory
FX3U/FX3UC comes with a standard internal memory of 64 k steps, which is 8 times
more memory than FX2N.
More memory means users can write larger and more complex programs, store
more data in file registers, or take greater
advantage of using IEC 61131-3 style programming tools.
8
A typical example of this can be found in
the Food and Pharmaceutical industries.
Here exact process data such as oven temperatures and cooking times or quantities
of ingredients mixed need to be stored
against production batches – all this
requires increased data handling and data
capacity within the PLC.
75 new
instructions
The FX3U/FX3UC has 75 new instructions
in comparison with FX2N. This now makes
available 249 instructions for program creation. All of the instructions follow the traditional FX Applied instruction concept
designed to make the task of application
building and program writing easier and
quicker, with less chance for errors.
FX3U/FX3UC a perfect PLC concept /// FX3U/FX3UC a perfect PLC concept ///
New instructions include greater control
over data processing with a range of new
comparison and string manipulation commands.
LOGE (Nr. 125)
Calculates the natural logarithm
in floating point
SORT2 (Nr.149)
Sort tabulated data
TBL (Nr. 152)
Batch data positioning mode
BAND (Nr.257)
Defines a band or range of valid
numbers
IVWR (Nr.273)
Write parameter to inverter
Some examples of new instructions from
the FX3U/FX3UC.
GOT1000
RS 232
RS 422
USB
RS 485
Inverter multidrop
Inverter 8
Inverter 1
FX3U/FX3UC has a range of flexible communication options.
Simple high
A great
speed positioning communicator
The FX3U/FX3UC has been designed with
six high speed counters that can each count
up to 100 kHz simultaneously per channel.
This, combined with three 100 kHz pulse
train outputs, means users can directly configure simple 3-axis positioning systems
without the use of additional modules.
FX3U/FX3UC has strengthened the communications capability of the FX Family
even further.
The new adapters allow up to three RS
communication channels to be operated
simultaneously allowing multiple HMIs to
be connected to a single FX3U/FX3UC CPU
or combinations of HMIs, third party
devices and programming tools – the
choice is yours.
The FX3U/FX3UC also supports a wide
range of network options including
AS-interface,
Profibus-DP,
CC-Link,
DeviceNet, CANopen as well as Ethernet.
Adapter modules increase positioning
performance.
However, the new high speed counter ADP
and pulse train ADPs can provide the
FX3U/FX3UC with maximum positioning
performance. Each unit can process signal
speeds of up to 200 kHz.
The FX3UC is the ideal choice for applications where there is not much space for the
controller hardware. The smallest base unit
with 8 digital inputs and 8 transistor outputs takes up just 27 % of the space
required for a comparable FX3U unit – and
yet the FX3UC incorporates all the features
of the FX3U.
The connections for the FX3UC inputs and
outputs on the front side can be wired with
ribbon cable connectors. For this purpose
system cabling sets and remote I/O terminal blocks for easy and fast connections are
available.
FX3U/FX3UC
at a glance
I/O range
16–384 (Discrete I/O, maximum 256)
Program memory
64 k steps (standard)
Basic instruction processing
0.065 µsec/logical instruction
Analog signal processing
Up to 80 analog inputs,
Up to 48 analog outputs
Analog resolution
8, 12 and 16 bits
Analog options
19 analog input, output and temperature blocks available
for selection
Positioning
Internal:
6 high speed counters (100 kHz)
2 high speed counters (10 kHz)
3 pulse train outputs (100 kHz),
transistor unit only
External (FX3U only):
High speed counter block (50 kHz)
High speed counter ADP module
(200 kHz)
Pulse train ADP (200 kHz)
Pulse train output block (1 MHz)
9
FX3G powerful micro control /// FX3G powerful micro control /// FX3G ///
FX3G an
industry standard
Highly flexible
A dual bus architecture provides flexible
expansion possibilities and with the ability
to handle analog, high speed, positioning,
and inverter control, the FX3G is able to
successfully adapt to a range of applications in industry areas such agriculture,
water processing, material handling, food
processing and more.
The great
communicator
FX3G PLCs are used in many applications for processing and packaging as well chilled storage
and transportion of food items.
Customized
control
Since its launch, the FX3G has been
a standard of micro PLC control.
10
The FX3G is an introductory compact PLC
and is the newest addition to the FX3
series, designed for simple yet performance-critical applications that require discrete control of up to 128 local I/O or up to
256 I/O with CC-Link remote I/Os.
Incorporating innovative FX3 series technology the customer is presented with a
suite of benefits. These include a large program memory to implement sophisticated
algorithms plus high speed execution to
enhance system productivity.
FX3G has the versatility to handle applications
from a wide range of industries.
With a wide range of network and serial
protocols available, such as Ethernet,
CC-Link and Modbus, the FX3G enables
seamless integration and data communications between both Mitsubishi Electric and
third-party devices. Furthermore, a built-in
USB port permits convenient connection
to any PC or laptop.
FX3G at a
glance
I/O range
14–256 (Discrete I/O, maximum 128)
Program memory
32 k steps (internal)
Basic instruction processing
0.21 µs or 0.42 µs/logical instruction
Analog signal processing
Up to 74 analog inputs
Up to 41 analog outputs
Analog resolution
8, 12 and 16 bit
Analog options
19 analog input, output and
temperature blocks available for
selection
Positioning
Internal:
Up to 4 high speed counters (max. 10 kHz)
up to 2 high speed counters (max. 60 kHz)
up to 3 (2) pulse train outputs (100 kHz)
/ FX1N modular micro /// FX1N modular micro /// FX1N modular micro ///
FX1N the
modular micro
Powerful
performance
The FX1N saves space, cost and engineering time with the use of powerful, built in,
positioning tools such two 100 kHz pulse
train outputs and up to two 60 kHz high
speed counters. These can be used to create simple 2-axis positioning systems,
linked to servo amplifiers or stepper motor
drivers without the need for additional PLC
hardware saving space, cost and engineering time.
FX1N has six shipping approvals. It has been used in applications from controlling temperature
in containers to managing diesel engines.
The FX1N provides a simple introduction
to modular micro control offering comprehensive functionality and expansion
options.
Compatibility
cuts costs
The FX1N offers comprehensive expansion
options.
The FX1N provides many user benefits
including excellent compatibility with
other FX Family PLCs. The FX1N is upwardly compatible to the FX2N/FX3G using
many of the FX2Ns I/O and special function
blocks. It also shares the same programming structure as the FX1S. This means
that users benefit from learning and using
one PLC programming syntax; resulting in
faster program development and reduced
programming errors.
FX1N at a
glance
I/O range
14–132
Program memory
8 k steps (standard)
Basic instruction processing
0.55 µsec/logical instruction
Analog signal processing
66 analog inputs
33 analog outputs
Analog resolution
8, 12 and 16 bits
Analog options
12 analog input, output and
temperature blocks available
for selection
Positioning
Internal:
2 high speed counters 60 kHz,
4 high speed counters 10 kHz
2 pulse train outputs (100 kHz),
transistor unit only
In addition, users benefit from a reduced
stock and spare parts requirement as the
FX1N uses the same expansion boards as
the FX1S and the same special function
and expansion I/O blocks as the FX2N.
11
FX1S micro control /// FX1S micro control /// FX1S micro control /// FX1S //
FX1S micro control
Remote control
The FX1S has an additional range of BD
expansion boards providing RS232,
RS485 and RS422 communications
options. These can be used to connect and
control various third party products such
as bar code readers or panel printers.
Simple
programming
The FX Family has a simple programming
structure combining Basic and Applied
instructions. The Basic instructions are
common to all FX Family PLCs. Applied
instructions provide the specialist control
options such as data comparisons, PID and
communications control, all of which are
available on FX1S. As each FX PLC range
increases in capability (FX1S, FX1N, FX3G,
FX3U/FX3UC) so do the number of available Applied instructions.
FX1S at a glance
FX1S has been used in a wide range of embedded control applications.
Fit and forget
FX1S offers communication and real time
control from a single unit.
Typically FX1S applications are small,
embedded control functions that are hidden
away or unaccessible under normal maintenance activities. This is why the FX1S has
been designed to be a robust low maintenance PLC. Features such as the maintenance free, 2000 step EEPROM memory and
real time clock management all help to make
the FX1S a self managing system, reducing
the impact on the maintenance engineer.
Example of connectivity to 3rd party products
12
I/O range
10–34
Program memory
2 k steps (standard)
Basic instruction processing
0.55 µsec/logical instruction
Analog signal processing
Up to 2 points
Analog resolution
12 bits
Analog options
2 analog input BD board
1 analog output BD board
Positioning
Internal:
2 high speed counters 60 kHz,
4 high speed counters 10 kHz
2 pulse train outputs (100 kHz),
transistor unit only
/// Programming /// Programming /// Programming /// Programming ///
Progressive
software concepts
The Mitsubishi FX PLC Family has a
worldwide reputation for reliability, performance and ease of use. These key
values have also been used to form
Mitsubishi’s integrated software concept, MELSOFT.
Simple and
intuitive
Mitsubishi Electric's iQ Works software is a
suite of four MELSOFT software packages
that enable intuitive programming and
setup of an iQ Platform system, including
system/network configuration, Q and FX
Series programming, Q Motion Controller
and Servo setup, GOT1000 HMI screen
design. This next generation software provides a fully customizable user friendly
environment with the developers in mind.
Productivity
tools
Programming software for PLCs is constantly evolving. Users are placing more
focus on reusable program code and
function block concepts. This helps
to reduce errors, reduce programming
time and to help manage the whole programming process – increasing overall
productivity.
One step further
with iQ Works
GX Developer offers ease of use for programmers of all skill levels.
First time user?
The key to any good software is that it is
simple to use. Mitsubishi’s GX Developer
PLC programming packages have achieved
this by using intuitive design.
For users who do not have the time to
take local training, there is the option of
using Mitsubishi’s home study software,
FX-TRN-BEG, where PLC programs can
be created, simulated and debugged in
the safety of a PC simulation.
They also have comprehensive help
functions and an advanced communications layer, ensuring safe reliable communication to the target PLC.
Often the biggest cost on a project is engineering time.
Choose what
you need
GX Developer offers users the chance to
program all Mitsubishi MELSEC PLCs
from a single package. However, for
users who only need support for FX
based systems there is GX Developer FX.
Mitsubishi also provide GX IEC Developer
packages, providing IEC61131-3 compliant programming in; Instruction List,
Ladder, Function Block, Structured Text
and SFC formats. Using standard programming languages, like IEC61131-3, on
large programming projects can help
users save costs by creating reusable PLC
code and Function Blocks.
Learning to program can be achieved quickly
using interactive software.
MELSOFT is a wide range of software solutions designed to optimize your plant productivity.
13
Networking solutions /// Networking solutions /// Networking solutions /
Networking and
communication solutions
Remote
maintenance
With communications technology it is now
possible to put PLC control in the most
remote locations. Using a PLC with a RS232
interface to a telemetry solution, such as a
GSM modem, allows the user the ability to
remotely monitor and maintain the system. It can also allow the remote system to
send alarm messages, warnings or general
status information back to the user’s central data processing centre.
FX Family PLCs have a wide range of communications options.
Applications are often required to integrate between each other across a factory,
to report production or tracking data back
for office based processing and in some
cases be remotely monitored and maintained when the application is in an inaccessible location. The FX Family of PLCs has
evolved to match this demand at
all levels.
Networks
make sense
Networked solutions to complex applications often make the overall solution easier
to achieve and more cost effective. For
example a conveyor system integrated
with a warehouse pick and place system
may extend over many hundreds of
meters, and by using a fieldbus, such as CCLink, wiring, troubleshooting and maintenance can be dramatically reduced.
14
Example of remote pumping station.
Easy
communications
Today’s FX Family of PLCs share a basic
communication concept where additional
RS232, RS422 or RS485 communications
boards can be added to the main
base unit without increasing the required
cabinet space. These can then be used for
communication to various third party
devices like bar code readers, printers
and modems.
FX Family PLCs, such as FX1N, FX3G, FX3U
and FX3UC, have a wider range of communications modules. These include options
for connection to open and bespoke networks such as Ethernet, Profibus-DP,
CC-Link, DeviceNet, CANopen, AS-interface
or Modbus for example.
/// Analog solutions /// Analog solutions /// Analog solutions /// Analog
Analog solutions
Analog control is one of the most important areas for any automation system.
Critically for users the concern is to match
the performance demanded by the application to the available solutions in a cost
effective way.
Inverter
Example: D-A
control can be
used to set the
speed of an
inverter driving
a motor.
Where is
analog used?
Analog control is widely used. In simple
terms it allows a variable signal to be used
to control items such as a motor’s speed or
to sense inputs such as fluid levels.
Example:
Temperature
control keeps
the liquid at the
correct viscosity.
쐽 Digital to analog (D-A) control
Here a digital PLC value is output as an analog signal. It can be used, for example, to
send a speed command to an inverter
which in turn causes the motor to increase
or decrease speed.
Example:
A-D control
can be used to
control the filling speed of
the container.
쐽 Analog to digital (A-D) control
In this type of control a variable signal is
sent to a PLC where it is converted in to a
direct digital value. An example of this
could be the measurement of the level of a
liquid in a storage tank so that the exact
amount of stored liquid can be controlled
by the PLC.
쐽 Temperature control
Temperature control is the third type of
analog control. An example of use could be
where the temperature of a furnace is
measured and compared by the PLC
against a set range. Additional heating or
cooling can then be applied to maintain a
constant temperature.
Analog solutions are an important part of control engineering and can be used to simplify and
accurately control actions happening in the production environment.
22 solutions
to choose from
The FX Family offers a wide range of analog
solutions from 1 and 2 channel BD boards
for FX1S up to 8 channel input blocks like
the FX2N-8AD where temperature, voltage
and current input can be mixed on the
same block. FX analog blocks also come in
a range of resolutions from 8 bit up to
16 bit signal processing. Overall there are
22 different analog options available to
users of the FX PLC Family.
With this range of choice and flexibility it is
sure that there will be a solution here for
most applications.
Example of temperature control.
15
Positioning solutions /// Positioning solutions /// Positioning solutions //
Positioning solutions
The larger the range of output pulse frequencies available means greater speed
and/or accuracy is achievable. For example, if a stepper motor with a larger number of steps is used, the travel distance
per step can be reduced, resulting in an
increased system accuracy.
X-Y table for simple shaping
쐽 High speed counter input
When a motor is being driven, its relative
position can be controlled by counting the
number of output pulses.
However, for a more accurate process,
reading the actual position from an
encoder feedback directly into a high
speed counter is preferred. This helps to
overcome issues of backlash and slippage
as the actual position is measured and
not assumed.
Horizontal drill station
Vertical drill station
Simple positioning solutions can be effectively managed within a standard FX PLC.
Using simple positioning solutions can
help increase the accuracy of the work
process, reduce waste and rework as well as
provide a higher quality of production.
Typical
applications
Simple positioning applications typically
involve independently controlled operational axis and can sometimes have many
requirements. In the example of an X-Y
table, a relative position is achieved by driving each axis until its target position is
achieved, regardless of what happens with
the other axis. There are two main elements
to achieve this type of positioning control.
Positioning built
in as standard
FX PLCs come with high speed counters
(in some cases up to 100 kHz) and pulse
train outputs (also in some cases up to
100 kHz) as standard. The high speed
counters can be configured in single
pulse train inputs, The high speed counters can be configured in a single or two
phase input.
Pulse train outputs can be configured to
provide continuous pulse streams at different frequencies or a set quantity of pulses
at a single frequency.
There are also optional modules and
adapters that can provide additional high
speed counters with performance up to
200 kHz. The same is true for pulse train
outputs with 200 kHz and 1 Mpps (1 MHz)
output options available.
쐽 Pulse train outputs
A stream of output pulses can be used as
a drive signal to a line driver, stepper
motor or servo amplifier, which then
causes the connected motor to perform
the positioning activity.
Example of conveyor belt control.
16
// Displays /// GOTs /// Displays /// GOTs /// Displays /// GOTs /// Displays ///
Display solutions
An increasingly important area of any
automation solution is the reporting and
display of operational information. This
data enables operators, maintenance
teams and business managers to make
informed decisions in the best interests of
the business.
쐽 The maintenance team
The critical information for a maintenance
engineer is the error and diagnostic data
within the PLC as this is used to diagnose
any process problems. However, additional
The right tool
for the right job
For maximum efficiency, each user requires
access to information at their work place in
a form that highlights the important data
for them first. This means a range of different tools are required. As an example, here
are three possible scenarios.
쐽 The machine operator
Machines often have a lot of manufacturing debris around or are subject to hygienic cleaning as in the food industry. Any display located in this environment would
need to have a high Ingress Protection (IP)
rating, indicating a high degree of waterproofness.
In the food industry hygiene is very important.
It may also be a benefit to the operator to
have a large and clear display to reduce the
chances for error from misreading, due to
poor light or small fonts being used. It is
also recognized that the use of graphics
also reduces the chances for reading errors
with complex data.
Data the way
you want it
Mitsubishi offers a wide range of visualization
solutions from simple data displays such as
the FX3U-7DM, advanced Graphic Operator
Terminals like the GOT1000 Series and E1000
Series, and a wide choice of software solutions from the MELSOFT software suite.
This powerful combination of hardware
and software means there is a cost effective
solution for most applications.
The FX3U-7DM can be directly mounted
within the PLC (FX3U) or mounted on the
front cabinet.
information regarding the operational
"hours run" or cycles processed, which
could be called soft information as it is calculated on operational parameters, could
allow the maintenance engineer to predict
possible failure and arrange preventative
maintenance.
Access to this data could be through the
machine operator's terminal, across a network or through a dedicated display
mounted inside or on the control
cabinet itself.
The GOT1000 is a typical HMI.
쐽 The business manager
In a production controllers office it would
be better to display information through a
network to their existing desktop PC. In
this application a piece of software such as
an OPC server/client, a Java applet, an
Active X control or a SCADA system would
allow lots of data from lots of sources to be
displayed in a clear and concise way giving
the production controller the overview of
the business operation that they need.
17
Application solutions /// Application solutions /// Application solutions ///
Where have FX PLCs
been used?
쐽 Leisure
– Multiplex cinema projection
– Animated mechatronics
(museums/theme parks)
쐽 Medical
– Respiration machine testing
– Sterilization
쐽 Pharmaceutical/chemical
– Dosing control
– Polution measurement systems
– Cryogenic freezing
– Gas chromotography
– Packaging
쐽 Plastics
– Plastic welding systems
– Energy management systems for
injection molding machines
– Loading/unloading machines
– Blow molding test machines
– Injection molding machines
Sanitation management on Eurostar rollingstock.
쐽 Printing
Customer applications with FX PLCs have
been wide spread from critical applications
in pharmaceutical industries to sublime
applications in the leisure industry.
However, the FX PLC Family still remains
the PLC of choice for many machine
builders as it is flexible, compact and easy
to use, which is why it is so often used.
Here are just a few examples of applications
that customers have completed in the past
쐽 Agriculture
– Plant watering systems
– Plant handling systems
– Saw mill (wood)
쐽 Textiles
쐽 Transportation
– Sanitation on passenger ships
– Sanitation on rail rolling stock
– Fire tender, pump management
– Waste disposal truck management
쐽 Utilities
– Waste water treatment
– Fresh water pumping
쐽 Building management
– Smoke detection monitoring
– Ventilation and temperature control
– Lift (elevator) control
– Automated revolving doors
– Telephone management
– Energy management
– Swimming pool management
쐽 Construction
– Steel bridge manufacturing
– Tunnel boring systems
18
쐽 Food and drink
– Bread manufacture (mixing/baking)
– Food processing (washing/sorting/
slicing/packaging)
Swimming pools are managed using FX PLCs.
ALPHA /// FX1S /// FX1N /// FX3G /// FX3U /// FX3UC ///
Technical Information Section
Further Publications within the PLC Range
System Q Family
Brochures
Product catalogues for programmable logic controllers and
accessories for the further MELSEC PLC series
HMI Family
Product catalogue for operator terminals, supervision software
and accessories
Inverter Family
Product catalogue for frequency inverters and accessories
Servo and Motion Systems
Product catalogue for servo amplifiers and servo motors as well as
motion controller and accessories
Robots Family
Product catalogue for industrial robots and accessories
Low Voltage Switchgears
Product catalogue for low voltage switchgears, magnetic
contactors and circuit breakers
Automation Book
Overview on all Mitsubishi automation products, like frequency
inverters, servo/motion, robots etc.
More information?
This product catalogue is designed to give an overview of the extensive range of FX Family of MELSEC PLCs. If you cannot find the
information you require in this catalogue, there are a number of ways you can get further details on configuration and technical issues,
pricing and availability.
For technical issues visit the www.mitsubishi-automation.com website.
Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and
services. Manuals and catalogues are available in several different languages and can be downloaded for free.
For technical, configuration, pricing and availability issues contact our distributors and partners.
Mitsubishi partners and distributors are only too happy to help answer your technical questions or help with configuration building.
For a list of Mitsubishi partners please see the back of this catalogue or alternatively take a look at the "contact us" section of our
website.
About this product catalogue
This catalogue is a guide to the range of products available. For detailed configuration rules, system building, installation and configuration the associated product manuals must be read. You must satisfy yourself that any system you design with the products in this catalogue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.
Specifications are subject to change without notice. All trademarks acknowledged.
© Mitsubishi Electric Europe B.V., Factory Automation - European Business Group
2
MITSUBISHI ELECTRIC
CONTENTS ///
System Description
웇 ALPHA and MELSEC PLC system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
웇 Extension modules and special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1
1 ALPHA Controllers
웇 Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
웇 Extension units and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2
2 MELSEC FX Base Units
웇
웇
웇
웇
웇
FX1S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FX1N series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FX3G series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
16
19
22
26
3
4
3 MELSEC FX Extension Units
웇 Powered compact extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
웇 Unpowered modular extension blocks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5
4 MELSEC FX Special Function Modules
웇
웇
웇
웇
웇
웇
웇
웇
Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Temperature control modules/Data logger modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
High-speed counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Network modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Communications modules, Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Adapter boards and communications adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
6
7
5 Accessories
웇
웇
웇
웇
웇
웇
Expansion Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Memory media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
External Terminal Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Power supply units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Backup batteries, Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Display modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
6 Dimensions
웇 Base and extension units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
웇 Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
웇 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7 Software & Programming
웇 Trainings and programming software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
웇 Programming unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Others
웇 Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
웇 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
MITSUBISHI ELECTRIC
3
/// SYSTEM DESCRIPTION
ALPHA and MELSEC PLC Systems
The ALPHA Series
The MELSEC FX Family
The ALPHA closes the gap between single
components and a PLC system. It combines all advantages of a PLC system in a
very compact housing and therefore provides a space and cost saving alternative
to relays and contactors.
The ALPHA series is suited to applications
in industrial machines and in automated
building services.
Key enhancements in the ALPHA2 include
a program capacity of 200 function blocks,
an extra-large display, expansion options
and a second communications port. The
instruction set, includes math operations,
PWM and SMS text messaging functions.
All this opens up possibilities for analog
and temperature control as well as remote
operation.
The MELSEC FX family includes a very
comprehensive range of base and expansion modules, enabling you to configure
a customised system tailored to your
precise requirements.
Depending on your application and control needs you can choose from the small,
attractively-priced, "stand-alone" FX1S
series, the expandable FX1N series or the
more powerful FX3G and FX3U series.
With the exception of the FX1S all FX series
can be expanded to adapt them to the
changing needs of your installations and
applications.
+
-
(A)
(B)
1
2
3
4
5
6
7
DC INPUT
8
POWER
24V DC
9
10
11
12
13
14
Network integration is also supported,
making it possible for your FX controllers
to communicate with other PLCs, controllers and HMIs. The PLC systems can be configured as local stations in MITSUBISHI networks. In addition these flexible units can
also be used as master or slave units on
fieldbus’s like Profibus/DP and CC-Link.
The MELSEC FX Family controllers also
support CANopen, DeviceNet,
AS-Interface and Ethernet. Special versions with E-Mark label (ECE requestion)
are available upon request for vehicle
application.
15
MITSUBISHI
ESC
100-240
VAC
L
N
100-240
VAC
X7
X5
X3
X1
S/S
X6
X4
X2
X0
0 1 2 3
4 5 6 7
L
N
X15
X7 X11 X13
X5
X3
X1
X14
S/S
X6 X10 X12
X4
X2
X0
0 1 2 3
4 5 6 7
8 9 10 11
12 13 14 15
MITSUBISHI
IN
MITSUBISHI
IN
POWER
RUN
ERROR
OK
POWER
RUN
ERROR
AL2-24MR-D
FX1N-24MR
OUT
FX1S-14MR
0 1 2 3
4 5 6 7
10 11
OUT
0 1 2 3
4 5
Y4
Y2
Y1
Y0
0V
Y5
Y3
24V COM0 COM1COM2
Y6 Y10
Y5
Y3
Y2
Y1
Y11
Y0
0V
COM4 Y7
COM2 COM3 Y4
24+ COM0 COM1
14MR
-ES/UL
24MR
-ES/UL
Expandability and Power
앬 The FX1N Series
The CPUs of the FX1N series offer more
power than the FX1S series, plus modular
4
Thus the FX3U and FX3UC series give you
the most powerful CPU for your application and combines all benefits of a compact PLC system with the performance of
a modular PLC system.
앬 The FX3G Series
32,000
16.000*
64,000
The FX3G is an introductory compact PLC
and is the newest addition to the FX3
series, designed for simple yet performance-critical applications. Incorporating
innovative FX3 series technology the customer is presented with a suite of benefits.
앬 The FX3UC Series
0.065
0.21 – 0.42
256
8,000*
0.55 – 0.7
2,000
132
FX1N
FX1S
The performance of the FX3UC is the same
as that of the FX3U series, but it has more
compact dimensions. It is the ideal choice
for applications where little space is available for the controller.
384
앬 The FX3U Series
The FX3U series gives you the freedom of
modular expandability, with a wide
selection of expansion modules and
special function modules.
The FX3U is the fastest PLC systems available, with a cycle time of just 0.065 μs per
logical instruction. This gives users a
powerful CPU delivering modular PLC
performance in a compact PLC design.
0.55 – 0.7
앬 The FX1S Series
The MELSEC FX1S series is the inexpensive
entry to the MELSEC FX family. With its
small dimensions it is also an excellent
alternative to relay/contactor control
configurations.
expansion capabilities. You can choose
from I/O expansion modules and special
function modules for a wide variety of
applications.
34
The MELSEC FX family is highly flexible,
enabling fast and efficient configuration
and programming for the application at
hand.
It is the ideal choice, no matter whether
you need to install a simple control
application requiring 30 I/Os (FX1S) or a
demanding, complex system with up to
384 I/O points (FX3U).
The use of memory cassettes can expand
the available programming space on some
FX Family PLCs while generally providing a
long term program storage option for all
FX PLC users. In addition, memory cassettes can also allow programs to be
switched at very short notice simply by
replacing the cassette.
There are five series in the MELSEC FX
family, each of which is designed for a
different application profile:
No. of inputs/outputs
Program steps
FX3G
FX3U/FX3UC
Cycle time (µs)
* Available with optional cassette
MITSUBISHI ELECTRIC
SYSTEM DESCRIPTION ///
Features
The modular design of the FX family makes
it extremely flexible, enabling it to be
used for a very broad range of applications.
You can configure tailor-made systems
by combining modules from a variety of
different categories (see figure).
All modules are electrically isolated from
their environment with optocouplers for
maximum reliability.
Digital I/O modules
For a variety of signal
levels with relay or
transistor switches
DIGITAL
INPUTS/OUTPUTS
Communications modules
Interface modules with
RS232/RS422/RS485 interfaces
for the connection of peripherals and PLC–PLC links.
Network modules for Ethernet,
Profibus/DP, CC-Link, AS-Interface, DeviceNet, CANopen and
for the configuration of proprietary Mitsubishi networks
DIGITALE
EIN-/AUSGÄNGE
COMMUNICATIONSMODULES
CPU
ANALOG
INPUTS/
OUTPUTS
ANALOGE
EIN-/AUSGÄNGE
KOMMUNIKATIONSMODULE
POSITIONING
MODULES
POSITIONIERMODULE
Analog I/O modules
Positioning modules
High-speed counter modules with support
for the connection of incremental rotary
transducers and positioning modules for
servo and stepping motor drives
Digital and special function
modules – configuration
The options for using digital and special
function modules are dictated by the CPU
used in the system.
When calculating the number of special
function modules you can use in a system
you must take both the number of digital
modules and the maximum number of
special function modules that can be used
into account.
The table on the right provides a simplified
guide to the number of modules you can
use in each system type. More detailed
information and the basic principles of
system configuration can be found in the
corresponding manuals.
MITSUBISHI ELECTRIC
For processing current/voltage
signals and temperature registration
with a direct connection option for
PT100 resistance thermometers and
thermocouplers
FX1S
Stand-alone PLC with 10 / 14 / 20 or 30 I/Os;
no special function modules but 1 I/O adapter board can be installed
FX1N
PLC with max. 132 I/Os
A maximum of 2 special function modules or digital expansion modules with up to
32 inputs and outputs (4x8 I/Os or 2x16 I/Os) or one special function module and one digital extension module with up to 16 inputs and outputs (2x8 I/Os or 1x16 I/Os)
can be connected.
FX3G
PLC with max. 256 I/Os
A maximum of 8 special function modules and digital extension modules with up to
128 I/Os can be connected to the right side of the main unit. In addition, a maximum of
4 special adapters from the FX3U series can be connected to the left side.
FX3U
PLC with max. 384 I/Os
To the left side of the main unit, a maximum of 10 special adapters from the FX3U series
can be connected. To the right side of the main unit, up to 8 special function modules and
digital extension modules with up to 256 I/Os can be connected.
FX3UC
PLC with max. 384 I/Os
To the left side of the main unit, a maximum of 6 special adapters from the FX3U series can
be connected. To the right side of the main unit, up to 4 special function modules and digital extension modules with up to 256 I/Os can be connected.
5
/// SYSTEM DESCRIPTION
The Components for an FX PLC System
A basic FX PLC system can consist of a
stand alone base unit, with the functionality and I/O range increased by adding
extension I/O and special function modules. The following section provides an
overview of options available.
Base Units
The entire FX PLC range can be AC or DC
powered with a mix of input and output
styles. The PLCs can be programmed with
the user friendly GX or GX IEC Developer
programming software, allowing programs to be transferred between different
FX PLCs. All PLC base units include an integrated real time clock.
Base units are available with different I/O
configurations from 10 to 128 points but
can be expanded to 384 points depending
upon the FX range selected.
Extension Boards
Extension adapter boards can be installed
directly into the base unit and therefore
do not require any additional installation
space. For a small number of I/O (2 to 4) an
extension adapter boards can be installed
directly into the (left-hand side) FX1S,
FX1N, FX3G or FX3U controller. Interface
adapter boards can also provide the FX
PLC with additional RS232, RS422, RS485
or USB interfaces. To connect special function modules (e.g. Ethernet module) a
communication adapter has to be
installed (except FX3UC).
Extension I/O Modules
Unpowered and powered extension I/O
modules can be added to the FX1N/FX3U
and FX3UC PLCs.
For expansion modules powered by the
base unit, the power consumption has to
be calculated as the 5 V DC bus can only
support a limited number of expansion I/O
(for further details please refer to next page
– calculation of the power consumption).
Special Function Modules
A wide variety of special function modules
are available for the FX1N, FX3G, FX3U and
FX3UC PLCs. They cover networking functionality, analog control, pulse train outputs, data logging function and temperature inputs.
Memory extension and operator
terminals
Each FX family base unit can be equipped
with a memory cassette. The programming unit interface enables the connection of programming tools like PC and
hand held programming units as well as
graphical operator terminals.
2424+
0
LINE STATION
N L
ON
6
5
4
3
1 2
OFF
ON
OFF
ON
8
9
A
B
C
D
E
7
F
FX 0N -3A
POWER
ERR
IN
ERROR STATION
OFF
ON
Network modules
Communications
boards
FX2N-16LNK-M
ALPHA2
쎲
FX1S
쎲
FX1N
쎲
FX3G
쎲
FX3U
쎲
FX3UC
쎲
Reference page
쎲
쎲
쎲
쎲
쎲
쎲
11, 46
Digital
—
—
쎲
쎲
쎲
쎲
29
Analog
—
—
쎲
쎲
쎲
쎲
33
Temperature
쎲
—
쎲
쎲
쎲
쎲
11, 34
AS-Interface
쎲
—
쎲
—
쎲
쎲
12, 39
CC-Link
—
—
쎲
쎲
쎲
쎲
38
CAN open
—
—
쎲
쎲
쎲
쎲
43
Ethernet
—
쎲
쎲
쎲
쎲
쎲
40
Profibus/DP
—
—
쎲
쎲
쎲
쎲
41
DeviceNet
—
—
—
—
쎲
쎲
43
Modbus RTU/ASCII
—
—
—
�
—
—
—
—
쎲
쎲
44
SSCNET
쎲
쎲
RS232
쎲
쎲
쎲
쎲
쎲
—
48
RS422
—
쎲
쎲
쎲
쎲
—
48
RS485
—
쎲
쎲
쎲
—
48
USB
—
—
—
—
쎲
쎲
—
47
쎲
쎲
쎲
쎲
44
Extensions for inside Digital
PLC installation
Analog
Extension modules
(installation outside
the PLC)
0
DG RUNB
A RUNA
MOD
1 2 3
11, 45
37
Communications
modules
RS232
—
쎲
RS485
—
쎲
쎲
쎲
쎲
쎲
44
Dedicated function
modules
High speed counter
—
—
—
—
쎲
쎲
36
—
—
—
—
쎲
쎲
37
Memory cassettes
쎲
쎲
쎲
쎲
쎲
쎲
12, 49
External Display
—
쎲
쎲
쎲
쎲
—
54
Positioning
� only via IEC function blocks
6
MITSUBISHI ELECTRIC
SYSTEM DESCRIPTION ///
Calculation of the Power Consumption
The power consumption figures on the
5 V DC bus for the special function modules are shown in the specifications tables
on the following pages.
The maximum permissible currents on the
5 V DC and 24 V DC bus are shown in the
table below.
Modules
Max. current
5 V bus
—
—
500 mA
500 mA
600 mA
560 mA
480 mA
400 mA
FX3G-14/24M첸-ES(ESS)
FX3G-40/60M첸-ES(ESS)
FX3U-16/32M첸-ES(ESS)
FX3U-48–128M첸-ES(ESS)
FX3UC-16MT/D(DSS)
FX3UC-32MT/D(DSS)
FX3UC-64MT/D(DSS)
FX3UC-96MT/D(DSS)
24 V bus
400 mA
400 mA
400 mA
600 mA
—
—
—
—
Max. residual current values (in mA) for FX3U-16M첸-E첸첸 through FX3U-32M첸-E첸첸
for the permissible configuration
Number of
additional
outputs
40
25
32
100
50
0
24
175
125
75
25
16
250
200
150
100
50
0
8
325
275
225
175
125
75
25
0
400
350
300
250
200
150
100
50
0
0
8
16
24
32
Number of additional inputs
40
48
56
64
Max. residual current values (in mA) for FX3U-48M첸-E첸첸 through FX3U-128M첸-E첸첸
for the permissible configuration
Number of
additional
outputs
The residual currents for the 24 V DC
service voltage at different input/output
configurations are shown in the tables on
the right.
A maximum of 256 I/Os are possible for
FX3U/FX3UC (128 I/Os for FX3G).
64
0
56
75
25
48
150
100
50
0
40
225
175
125
75
25
32
300
250
200
150
100
50
0
24
375
325
275
225
175
125
75
25
16
450
400
350
300
250
200
150
100
50
0
8
525
475
425
375
325
275
225
175
125
75
25
0
600
550
500
450
400
350
300
250
200
150
100
50
0
0
8
16
24
32
Number of additional inputs
40
48
56
64
72
80
88
96
An external power supply is necessary, if the residual current for the 24 V supply of the
special function modules is not sufficiant.
Sample Calculations
The tables below and on the right show
different examples for sample power
calculation for a PLC system.
The current values for the special function
modules can be found in the specifications
on the following pages.
Comparison with the current value tables
show that the calculated figures for the
5 V bus lie within the allowable ranges.
In the example below all units can be
supplied sufficiently with the internal
24 V power supply.
Module
FX3U-48MR/ES
No.
1
24 V DC calculation
Module
5 V DC calculation
No.
Current / module
Calculation
Current / module
Total current
600 mA
+600 mA
+500 mA
+500 mA
3
90 mA
-180 mA
110 mA
-220 mA
2
160 mA
-320 mA
120 mA
-240 mA
1
240 mA
-240 mA
—
—
FX3U-80MR/ES
1
FX3U-4AD
FX3U-4DA
FX3U-ENET
-140 mA !!!
500 – 460 mA
Result:
40 mA (OK !)
An external 24 V power supply has to
be added in the example above.
Number of I/Os
24 V DC calculation
X
Y
X/Y
24
24
—
Total 햲
X=8
Y = 24
Total current 햳
5 V DC calculation
Current / module
Total current
500 mA
+500 mA
—
0 mA
—
0 mA
FX2N-16EYR-ES/UL
1
—
16
—
FX2N-8EX-ES/UL
1
8
—
—
FX2N-8EYR-ES/UL
1
—
8
—
FX3U-4AD-PT-ADP
1
—
—
—
-50 mA
FX2N-32ER-ES/UL
1
16
16
—
+150 mA residual current for extension unit
FX2N-32ER-ES/UL
690 mA
—
0 mA
0 mA
120 mA
-120 mA
-50 mA
130 mA
➞
+325 mA
—
0 mA
30 mA
-15 mA
+275 mA (OK!)
FX2N-16EX-ES/UL
1
16
—
—
FX2N-10PG
1
—
—
8
1
—
—
8
FX2N-32CCL
Result:
햲
➞
64 + 64 + 16 = 144! (< 256) OK!
Total no. of I/Os which are connected to a base unit to calculate the max. residual current values (see tables)
MITSUBISHI ELECTRIC
X = 16
Y=0
+100 mA (OK!)
햳
+485 mA (OK!)
+690 mA
-130 mA
+440 mA (OK!)
see tables above (max. residual current values)
7
/// ALPHA SYSTEM OUTLINE
왎 The ALPHA 2 Series
1
ALPHA SERIES
The analog inputs (0–10 V, 9 bits
resolution) can be used very easily due
to the integrated gain function and a
Schmitt-trigger.
Up to 15 inputs can be used as digital
inputs and up to for
(controllers with 24 V DC supply).
The communication with a computer and with external peripherals is supported by the two
integrated serial interfaces.
Integrated calender/real-time function
with up to 1200 switch ON
or OFF commands in one program
-
+
(A)
5
4
3
2
1
(B)
6
7
DC INPUT
8
9
10
11
12
13
POWER
24V DC
14
15
MITSUBISHI
ESC
Direct programming via
8 function keys on the front control
panel without any additional programming device
The units can be expanded
to additional inputs/outputs
with extension modules to
be mounted directly into the
controller
OK
AL2-24MR-D
Flexible mounting through integrated
DIN rail adapter and screw fixing
The program is stored in a maintenancefree EEPROM with a memory capacity of
5000 bytes.
Large LC display for programming,
entering, and editing plain text,
values and bar graphs
A backup battery is not required.
Password protection
can be activated.
Description of the Unit Components
Power supply
terminals
Terminals for
digital/analog inputs
Mounting hole
+
Adapter for
DIN rail mounting
-
(A)
(B)
1
2
3
4
5
6
7
DC INPUT
8
9
10
11
12
13
14
15
Connector for PC,
GSM, modem and
other automation
components
POWER
24V DC
ESC
Slot for
EEPROM cassette
or connector for
programming cable
Operating keys (8 pcs.)
MITSUBISHI
OK
AL2-24MR-D
Protective cover
LCD display
(4 lines x 12 characters)
Housing cover
(place holder) for the
extension modules
Connection for
extensions
Terminals for
digital outputs
8
MITSUBISHI ELECTRIC
ALPHA BASE UNITS ///
왎 Specifications ALPHA 2
ALPHA 2 Base Units
(A)
(B)
1
2
3
4
6
5
7
DC INPUT
8
9
10
11
POWER
24V DC
12
13
14
The ALPHA 2 controllers offer simple reliable control for a range
of automation applications including lighting, air conditioning,
security systems, and temperature and water control.
15
1
ALPHA SERIES
-
+
Special features:
MITSUBISHI
앬
앬
앬
앬
앬
앬
ESC
OK
AL2-24MR-D
Transistor and relay output options
Analog input/output
High Speed counters up to 1 kHz
GSM function for communication with mobile phones
Language support for 8 different languages
Display unit for messages and function block data
e.g. AL2-24M쏔-쏔
Base Units with 10–24 I/Os
AL2-10MR-D
AL2-14MR-A
AL2-14MR-D
AL2-24MR-A
AL2-24MR-D
24
Electrical specifications
Integrated inputs/outputs
10
10
14
14
24
Power supply
100–240 V AC
24 V DC
100–240 V AC
24 V DC
100–240 V AC
24 V DC
Digital inputs
6
6
8
8
15
15
Analog inputs
—
6
—
8
—
8
Channels
—
6
—
8
—
8
Integrated outputs
4
4
6
6
9
9
4.0
5.5
7.5
7.0
9.0
2.5/0.75
4.5/2.0 240 V AC
3.5/1.5 120 V AC
4.0/1.0
5.5/2.5 240 V AC
4.5/2.0 120 V AC
5.0/1.0
Max. power consumption
W 4.9
Typ. power
consumption
240 V AC
W 3.5/1.85
3.0/1.55 120 V AC
All I/Os
ON /OFF
Weight
Dimensions (WxHxD)
Order information
Accessories
kg 0.2
mm 71.2x90x55
Art. no. 215070
0.2
0.3
0.3
0.35
0.3
71.2x90x55
124.6x90x52
124.6x90x52
124.6x90x52
124.6x90x52
215071
215072
215073
215074
215075
Power supplies with DIN-rail or wall mounting possibilities for powering the 24 V DC modules (refer to the power supply chapter in this catalogue)
MITSUBISHI ELECTRIC
9
/// GENERAL SPECIFICATIONS
Environmental Specifications
ALPHA SERIES
1
Ambient temperature
Display: -10–55 °C, Hardware: -25–55 °C (storage temperature: -30–+70 °C)
Protection rating
IP20
Noise immunity
1000 Vpp with noise generator; 1 µs at 30–100 Hz, tested by noise simulator
Dielectric withstand voltage
3750 V AC, >1 min. according to EN60730
Allowable relative humidity
35–85 % (no condensation)
Shock resistance
Acc. to IEC 68-2-27: 147 m/s2 acceleration, 11 ms 3x3 directions
Vibration resistance
direct mounting
DIN rail mounting
Acc. to IEC-2-6: 19.6 m/s2 acceleration, 80 min. in each direction
Acc. to IEC-2-6: 9.8 m/s2 acceleration, 80 min. in each direction
Insulation resistance
500 V DC, 7 MW acc. to EN60730-1
Ambient conditions
No corrosive gases, no dust
Certifications
Please refer to pages 66–67 in this catalogue
Electrical Specifications
Type
Power supply
24 V DC
Inrush current at ON
£7.0 A (at 24 V DC)
Allowable momentary power failure time 5 ms
Digital Inputs
24 V DC
Input voltage
(+20 %/-15 %)
The input current changes
depending on Source or Sink.
For Sink:
(AL2-10/14/24MR-D)
= 5.5 mA, 24 V DC
Input current
For Source:
(AL2-10/14MR-D)
= 6.0 mA, 24VDC
(AL2-24MR-D)
= 5.5 mA, 24 V DC
100–240 V AC (50/60 Hz)
£6.5 A (at 240 V AC)
10 ms
100–240 V AC
(+10 %/-15 %), 50/60 Hz
I01–I08
0.13 mA/120 V AC*
0.25 mA/240 V AC*
I09–I15
0.15 mA/120 V AC*
0.29 mA/240 V AC*
OFF®ON
ms 10–20
ON®OFF
ms 10–20
35–85 ms, 120 V AC
25–55 ms, 240 V AC
35–85 ms, 120 V AC
50–130 ms, 240 V AC
0–500
9 bit, (10 V/500)
ms 8
0–10 V DC
kW 142 ±5 %
±5 % (0.5 V DC)
—
—
—
—
—
—
Response time
Analog Inputs
Analog input range
Resolution
Conversion speed
Voltage
Impedance
Accuracy
Type
Switching voltage (max.)
Rated current
Max. switching
load
Minimum load
Response time
- inductive load
Relay
V 250 V AC, 30 V DC
10M, 14M: 8 A/point
24M (001-004): 8 A/point
24M (005-009): 2 A/point
14M, 24M:249 VA, 250 V AC/373 VA, 250 V AC
24M: 93 VA, 125 V AC/93 VA, 250 V AC
10 mA, 5 V DC
ms £10
* Current leakage from the sensors connected to the inputs might provide enough current to turn the
controller On. Do not use two wire sensors
Programming Specifications
Programming method
Program capacity
Program processing
Number of available instructions
Program storage
Data storage
Processing time
Real-time clock
Program protection
10
Function block
200 function blocks or 5000 bytes
Cyclic processing of the stored program
38 different function blocks
Integrated EEPROM and optional additional EEPROM cassette
At voltage loss the current status of values, running time meters, and real-time data are stored for up to 20 days (at temperatures of 0 to 25 °C) through
integrated capacitors
1 ms + 20 ms/log. instruction (complex commands 500 ms/instruction)
Seconds, minutes, hours, day of week, month, year (4-digit); accuracy: 5 s/day; automatic summer and winter time toggling
Program and keys (3 levels)
MITSUBISHI ELECTRIC
EXTENSION MODULES ///
Digital Extension Modules
RELAY
OUTPUT
MITSUBISHI
4EYR
Note: The digital extension modules cannot be used with the AL2-10MR series.
EO4
EO3
Inputs
Integrated inputs
Input voltage
Input current
Outputs
Integrated outputs
Output type
Switched voltage (max.)
V
Rated current
A
Electrical specifications
Power Supply
AC range (+10 %, -15 %)
Mechanical specifications
Weight
kg
Dimensions (WxHxD)
mm
Order information
AL2-4EX
AL2-4EYR
AL2-4EYT
4
220–240 V AC
7.5 mA at 240 V AC (50 Hz),
9.0 mA at 240 V AC (60 Hz)
4
24 V DC (+20 %, -15 %)
—
—
—
—
5.4 mA ±1 mA at 24 V DC
—
—
—
—
—
—
—
—
—
—
4
Relay
250 V AC, 30 V DC
2 A per output
4
Transistor
5–24 V DC
1 A per output
220–240 V AC
24 V DC
100–240 V AC
24 V DC
0.05
53.1x90x24.5
0.05
53.1x90x24.5
0.05
53.1x90x24.5
0.05
53.1x90x24.5
142521
142523
142524
Art. no. 142522
Note: EI1 and EI2 of the AL2-4EX can be used as high-speed counter inputs. In each case the response time for the high-speed counter inputs will be 0.5 ms or less.
The AL2-4EX-A2, AL2-4EX, AL2-4EYR and AL2-4EYT modules can not be used with the AL2-10MR series.
Analog Extension Modules
+
-
POWER
24V DC
V1+
V1-
CH1
OUTPUT
V2+
V2-
CH2
0~10V
MITSUBISHI
+
-
V1+
V1-
V2+
V2-
POWER
POWER
24V DC
CH1
OUTPUT
CH2
0~10V
+
MITSUBISHI
CH2
CH1
-50°C Line
200°C -50°C Line 200°C
POWER
CH2
CH1
-50°C Line
450°C -50°C Line 450°C
V1+
ANALOG
OUTPUT
MITSUBISHI
CH2
CH1
L1-
I1-
L2+
L2-
AL2-2TC-ADP
-50~450°C
K-type Thermocouple
CH2
I2-
2DA
ANALOG
OUTPUT
V2+
L1+
L1-
SLD L2+
L2-
VI1-
I1+
AL2-2PT-ADP
PT100 -50~200°C
L1+
CH1
-
POWER
24V DC
I2+ VI2-
SLD
Analog inputs
Integrated inputs
The analog extension modules significantly increase the range of applications for the
ALPHA 2. With these modules it is possible to output voltage or current signals or to
measure temperatures.
Three different analog extension modules are available:
앬 The AL2-2DA offers two additional analog outputs for the ALPHA 2 and converts a
digital input value into a voltage or a current. This module is inserted directly into the
ALPHA 2.
Note: the AL2-2DA cannot be used with the AL2-10MR series.
앬 The AL2-2PT-ADP connects an external PT100 sensor to convert temperature readings
into analog signals (0–10 V).
앬 The AL2-2TC-ADP connects thermocouple sensors (K type) to convert temperature
readings into analog signals (0–10 V).
AL2-2TC-ADP
2
Thermocouple (K type), isolated type
(IEC 584-1 1977, IEC 584-2 1982)
-50–+450 °C
Connectable temperature sensors
—
Compensated range
Analog outputs
Integrated outputs
—
2
PT100 sensor
Temp. coefficient 3.850 ppm/°C (IEC 751)
-50–+200 °C
2
0–10 V DC (5 k⏲ 1 M⏲)
4–20 mA (max. 500 ⏲)
—
—
—
—
—
—
2
24 V DC (-15–+10 %), 70 mA
2
24 V DC (-15–+20 %), 1 W
2
24 V DC (-15–+20 %), 1 W
0.07
35.5x90x32.5
0.07
35.5x90x32.5
151238
151239
voltage
current
Electrical specifications
Number of channels
Power Supply
Mechanical specifications
Weight
Dimensions (WxHxD)
—
AL2-2PT-ADP
Analog output
range
Order information
kg 0.05
mm 53.1x90x24.5
Art. no. 151235
MITSUBISHI ELECTRIC
11
1
ALPHA SERIES
There are 4 different extension modules available for the ALPHA 2, which allow the controller
to be extended through additional inputs or outputs. The modules are inserted directly
into the ALPHA 2 and therefore do not take up any additional space.
The AL2-4EX has the additional feature that 2 inputs may be used as high-speed counters
with a counting frequency of 1 kHz.
All modules feature photocoupler insulation for all I/Os.
EO2
EO1
/// EXTENSION MODULES AND ACCESSORIES
AS-Interface Module AL2-ASI-BD
The Actuator Sensor Interface module AL2-ASI-BD in combination with an ALPHA 2 controller facilitates the data communications via an AS-Interface system. The AL2-ASI-BD is
attached to an ALPHA 2 series module and forms a slave unit. Up to 4 inputs and 4 outputs can be exchanged with the AS-Interface master.
The addresses of the slave devices in the AS-Interface are assigned either automatically
via the master in the network or via a programming device (software).
The maximum communication distance is 100 m without a repeater. If 2 repeaters are
used, the distance is extended to up to 300 m.
For the AS-Interface a separate power supply is required. The communication signal is
superimposed on the power supply of the AS-Interface bus.
ASI+
ASI+
ASIASI-
ALPHA SERIES
1
Note: The AL2-ASI-BD cannot be used with the AL2-10MR series.
Module type
Number of I/O points
External power supply
External current consumption
Communications protocol
Weight
Dimensions (WxHxD)
Order information
Slave module
4 inputs, 4 outputs
30.5 V DC (AS-Interface power supply)
mA Max. 40
AS-Interface standard
kg 0.05
mm 53.1x90x24.5
Art. no. 142525
With the AL2-EEPROM-2 memory cassettes, a new program can be transferred to the
ALPHA 2 controller’s internal system memory from the cassette, or the program of the
internal system memory can be saved to the cassette.
If the memory cassette is used, a certain program can be run temporarily by simply
plugging the external memory module onto the ALPHA 2.
After removing the memory cassette, the former program in the internal memory
becomes active again.
The memory cassette AL2-EEPROM-2 is not a memory expansion device, but a medium
for data exchange.
MADE IN JAPAN
AL2-EEPROM
Memory Cassette AL2-EEPROM-2 Memory Media
Memory type
Application
Memory capacity
Function blocks
Dimensions (WxHxD)
Order information
EEPROM
ALPHA 2
5,000 bytes
Max. 200
mm 10x45x25
Art. no. 142526
Interface Cable AL-232CAB
The AL-232CAB is an RS232C interface cable. It connects the ALPHA 2 controller to a
personal computer running the programming software for the ALPHA 2 controller.
The cable ensures a galvanic isolation between the ALPHA 2 controller and the personal
computer. The cable AL-232CAB can not be used for any other connection.
GSM Cable AL2-GSM-CAB
AL-232CAB
The GSM AL2-GSM-CAB is an RS232C interface cable and it is used to connect the
ALPHA 2 controller to a normal or GSM modem, a personal computer or other serial
devices. It can transfer SMS data to a GSM modem for onward transmission to mobile telephones or e-mail addresses. It also permits remote monitoring and remote maintenance.
Note: The above cables cannot be used with the AL2-10MR series.
Connector
Application
Length
AL2-GSM-CAB
LOT .24
MITSUBISHI ELECTRIC
AL2-GSM-CAB
12
Order information
9-pin D-SUB female connector
ALPHA 2 <-> PC
m 2.5
Art. no. 87674
9-pin D-SUB male connector
ALPHA 2 <-> PC, modem
1.5
142528
MITSUBISHI ELECTRIC
BASE UNITS FX1S SERIES ///
The MELSEC FX1S Series
0
4 12
5 3
6
7
IN
All units feature two analog
potentiometer for setpoint
value entry and an integrated
RUN/STOP switch.
R W
U
ER N ER
R
O
R
1S
FX
0 O
U
4 12 T
5 3
-1
4M
R
PO
I
IS
H
B
S
U
IT
2
Square pulse output
(this applies only to transistor units.)
high speed pulse
Two
outputs for frequencies up to
100 kHz for outputting
and controlling stepping motors
M
EL
SE
C
M
Integration of interface, extension, and functions adapters for
direct installation in the base unit
The internal service power
supply unit for 24 V DC has
a capacity of 400 mA.
Note: service power supply
is only available for AC Power
Supply types.
Integrated real-time
clock with year, month,
day and time
Integrated serial RS422
interface for direct communication with computers
Flexible installation with the
integrated DIN rail adapter and
screw fastening holes for mounting on flat surfaces
Password access protection
facility for effective protection
of your intellectual property.
Your PLC programs are stored in a maintenance-free EEPROM user memory
with a capacity of 2,000 program steps,
so there is no need for a backup battery
to protect against power failures.
Description of the Unit Components
Protective cover
Terminal cover
Fixing hole
Connection of the
power supply
Terminals for
digital inputs
Adapter interface
100-240
VAC
L
N
X7
X5
X3
X1
S/S
X6
X4
X2
X0
0 1 2 3
4 5 6 7
Slot for adapter
LEDs for indicating
the input status
IN
RUN/STOP switch
POWER
RUN
ERROR
2 analog potentiometers
Connection for
programming units
Service voltage
source
FX1S-14MR
OUT
0 1 2 3
4 5
Y4
Y2
Y1
Y0
0V
Y5
COM2 Y3
24V COM0 COM1
14MR
-ES/UL
MITSUBISHI
LEDs for indicating the
operating status
LEDs for indicating
the output status
Housing cover
Terminals for
digital outputs
MITSUBISHI ELECTRIC
13
FX BASE UNITS
High-speed inputs for fast counting
tasks with counting frequencies of
up to 60 kHz and interrupt processing
capabilities
/// BASE UNITS FX1S SERIES
왎 Base Units
þ FX1S ¨ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Base Units FX1S
The FX1S series base units are available with 10 to 30 input/output
points.
It is possible to choose between relay and transistor output type.
Note: Versions with UL certification are available on request.
2
100-240
VAC
L
N
Special Features:
X7
X5
X3
X1
S/S
X6
X4
X2
X0
앬
앬
앬
앬
앬
앬
앬
0 1 2 3
4 5 6 7
MITSUBISHI
FX BASE UNITS
Integrated power supply (AC or DC powered)
Maintenance-free EEPROM memory
Ample memory capacity (2000 steps) and device ranges
High-speed operations
Incorporated positioning control
Integrated real-time clock
System upgrades by exchangeable interface and I/O adapter
boards for direct fitting into the base unit
앬 LEDs for indicating the input and output status
앬 Standard programming unit interface
앬 User-friendly programming systems, including IEC 61131.3
(EN 61131.3)-compatible programming software, HMIs and
hand-held programming units
IN
POWER
RUN
ERROR
FX1S-14MR
OUT
0 1 2 3
4 5
Y4
Y2
Y1
Y0
0V
Y5
OM2 Y3
24V COM0 COM1C
14MR
-ES/UL
Base Units with 10–14 I/Os
FX1S-10
MR-ES/UL
FX1S-10
MT-DSS
FX1S-14
MR-DS
FX1S-14
MR-ES/UL
FX1S-14
MT-DSS
14
24 V DC
8
6
14
100–240 V AC
8
6
Relay
Relay
14
24 V DC
8
6
Transistor
(source)
Max. number inputs/outputs
Power supply
Integrated inputs
Integrated outputs
10
24 V DC
6
4
10
100–240 V AC
6
4
Output type
Relay
Relay
10
24 V DC
6
4
Transistor
(source)
19
0.3
60x90x75
6
0.22
60x90x49
6.5
0.22
60x90x49
19
0.3
60x90x75
6.5
0.22
60x90x49
141243
141246
141247
141248
141249
FX1S-20
MR-ES/UL
FX1S-20
MT-DSS
FX1S-30
MR-DS
FX1S-30
MR-ES/UL
FX1S-30
MT-DSS
30
24 V DC
16
14
30
100–240 V AC
16
14
Relay
Relay
30
24 V DC
16
14
Transistor
(source)
Power consumption
Weight
Dimensions (WxHxD)
Order information
W 6
kg 0.22
mm 60x90x49
Art. no. 141240
Base Units with 20–30 I/Os
Max. number inputs/outputs
Power supply
Integrated inputs
Integrated outputs
20
24 V DC
12
8
20
100–240 V AC
12
8
Output type
Relay
Relay
20
24 V DC
12
8
Transistor
(source)
20
0.4
75x90x75
7
0.3
75x90x49
8
0.35
100x90x49
21
0.45
100x90x75
8
0.35
100x90x49
141252
141254
141255
141256
141257
Power consumption
Weight
Dimensions (WxHxD)
Order information
14
W 7
kg 0.3
mm 75x90x49
Art. no. 141251
MITSUBISHI ELECTRIC
BASE UNITS FX1S SERIES ///
왎 Base Units
þ FX1S ¨ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Environmental Specifications
0–55 °C (storage temperature: -20–+70 °C)
Protection
IP10
Noise durability
1000 Vpp with noise generator; 1 µs at 30–100 Hz
Dielectric withstand voltage
1,500 V AC, 1 min. (500 V AC for direct voltage modules)
Ambient relative humidity
35–85 % (non-condensing)
Shock resistance
Acc. to IEC/EN 68-2-27: 15G (3 times each in 3 directions for 11 ms)
2
Vibration resistance
Acc. to IEC/EN 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting
Insulation resistance
500 V DC, 5 MW
Ground
Class D: Grounding resistance 100 W or less
Fuse rating
AC models: 250 V 1.0 A; DC models: 0.8 A
Environment
Avoid environments containing corrosive gases, install in a dust-free location.
Certifications
Please refer to pages 66–67 in this catalogue
FX BASE UNITS
Ambient temperature
Electrical Specifications
Type
Power supply
24 V DC (+10 %/-15 %)
Inrush current at ON
10 A/0.1 ms (at 24 V DC)
Allowable momentary power
5 ms
failure time
Primary power supply
24 V DC, 400 mA
External power supply (24 V DC) —
100–240 V AC (+10 %/-15 %),
50/60 Hz (±10 %)
15 A/5 ms (at 100 V AC);
25 A/5 ms (at 200 V AC)
10 ms
400 mA
Switching voltage (max.)
- per output
Max. output
current
- per group*
- inductive load
Max. switching
current
- lamp load
Response time
Life of contacts (switching times)**
V
A
A
W
ms
Transistor
modules
<250 V AC, <30 V DC
5–30 V DC
2
0.5
8
0.8
80 VA
12 W
100
1.2
10
0.2
3,000,000 at 20 VA; 1,000,000 at 35 VA;
200,000 at 80 VA
* The limitation applies only per reference terminal for each group, 1 and 4 outputs for relays and
transistors. Please observe the terminal assignments for the group identification.
** Not guaranteed by Mitsubishi Electric.
Programming Specifications
Program data
Program memory
2.000 steps EEPROM (internal)
Program execution
Periodical execution of the stored program
Program protection
Password protection with 3 protection levels. Note: Protection levels may only be changed with FX-10P/FX-20P/FX-30P.
Number of instructions
27 sequence instructions, 2 step ladder instructions, 85 applied instructions
Cycle period
0.55–0.7 µs/logical instruction
Operands
Internal relays
512 total, with 384 general (M0–M383) and 128 latched (M384–M511)
Special relays
256 (M8000–M8255)
State relays
128
Timers
64 (max. 63 timers, partially switchable to 100 ms and 10 ms)
External setpoint entry via potentiometer
2 potentiometers
Counter
32 (16 bit), C0–C31
High-speed counter inputs
1 phase, 6 points max: 60kHz/2 points, 10kHz/4 points ; 2 phase, 2 points max: 30kHz/1 point, 5kHz/1 point
Data register
256 subtotal (128 general (D0–D127) and 128 latched (D128–D255))
Index register
16
Special register
256 (16 bit), D8000–D8255
Pointer
64, P0–P63
Nesting operands
8, N0–N7
Interrupt inputs
6
Constants
16 bits: K: -32768 to +32767, hex: 0–FFFF
32 bits: K: -2147483648 to +2147483647, hex: 0–FFFF FFFF
MITSUBISHI ELECTRIC
15
/// BASE UNITS FX1N SERIES
The MELSEC FX1N Series
High-speed inputs for fast
counting tasks with counting
frequencies of up to 60 kHz and
interrupt processing
capabilities
The base units can be expanded
for up to 128 inputs/outputs with
different extension units.
0
4 1
10 5
2
14 1
1 6 3
15 12
7
13
Integration of
PO
R W
U
ER N ER
R
O
R
IN
for direct installation in the base unit
MR
I
H
IS
IT
S
U
B
0
O
4 1 U
T
10 5
2
11
6 3
7
-24
1N
FX
M
EL
SE
C
M
FX BASE UNITS
2
Integrated RUN/STOP switch and
two analog potentiometers for
setpoint value entry.
The base units have integrated,
maintenance-free EEPROM
user memory for up to 8,000
PLC program steps, so there
is no need for a backup battery to
protect against power failure.
You can also configure password
protection to prevent unauthorized access to your programs.
Integrated real-time
clock with year, month,
day and time
Square pulse output
(This only applies for transistor units.)
Two integrated high-speed pulse
outputs for frequencies up to
100 kHz for outputting pulse
signals and controlling stepping
motors
External EEPROM memory
cassettes for PLC program storage
Description of the Unit Components
Protective cover
Terminals for
digital inputs
Terminal cover
Connection of the
power supply
Fixing hole
Extension bus
RUN/STOP switch
100-240
VAC
Slot for memory cassettes,
displays and ADPs.
L
X15
X7 X11 X13
X5
X3
X1
X14
S/S
X6 X10 X12
X4
X2
X0
N
0 1 2 3
4 5 6 7
11
10
8 9
12 13 14 15
IN
POWER
RUN
ERROR
2 analog potentiometers
Connection for
programming units
Terminals for
service voltage source
Terminals for
digital outputs
LEDs for indicating the
operating status
FX1N-24MR
OUT
0 1 2 3
4 5 6 7
10 11
Y6 Y10
Y5
Y3
Y2
Y1
Y11
Y0
0V
COM4 Y7
COM2 COM3 Y4
24+ COM0 COM1
LEDs for indicating
the input status
24MR
-ES/UL
LEDs for indicating
the output status
MITSUBISHI
Housing cover
Lid
Terminal cover
Protective cover
16
MITSUBISHI ELECTRIC
BASE UNITS FX1N SERIES ///
왎 Base Units
¨ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Base Units FX1N
The FX1N series base units are available with 14 to 60 input/output points.
It is possible to choose between relay and transistor output type.
Note: Versions with UL certification are available on request.
L
N
Special Features:
X15
X7 X11 X13
X5
X3
X1
X14
S/S
X6 X10 X12
X4
X2
X0
0 1 2 3
4 5 6 7
8 9 10 11
12 13 14 15
MITSUBISHI
IN
POWER
RUN
ERROR
FX1N-24MR
OUT
0 1 2 3
4 5 6 7
10 11
Y6 Y10
Y5
Y3
Y2
Y1
Y11
Y0
0V
COM4 Y7
COM2 COM3 Y4
24+ COM0 COM1
2
앬 Integrated serial interface for communication between
24MR
-ES/UL
앬
앬
앬
앬
앬
앬
앬
Personal computers and HMI
Standard programming unit interface
LEDs for indicating the input and output status
Detachable terminal blocks for units with 14, 24, 40, and 60 I/Os.
Slot for memory cassettes
All DC models with variable voltage from 12 up to 24 V
Integrated real-time clock
Exchangeable interface and I/O adapter boards for direct fitting
into the base unit
Base Units with 14–24 I/Os
Specifications
FX1N-14
MR-DS
FX1N-14
MR-ES/UL
FX1N-14
MT-DSS
FX1N-24
MR-DS
FX1N-24
MR-ES/UL
FX1N-24
MT-DSS
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
14
12–24 V DC
8
6
14
100–240 V AC
8
6
24
12–24 V DC
14
10
24
100–240 V DC
14
10
Output type
Relay
Relay
14
12–24 V DC
8
6
Transistor
(source)
Relay
Relay
24
12–24 V DC
14
10
Transistor
(source)
29
0.45
90x90x75
13
0.45
90x90x75
15
0.45
90x90x75
30
0.45
90x90x75
15
0.45
90x90x75
141259
141260
141261
141262
141263
Power consumption
Weight
Dimensions (WxHxD)
Order information
W 13
kg 0.45
mm 90x90x75
Art. no. 141258
Base Units with 40–60 I/Os
Specifications
FX1N-40
MR-DS
FX1N-40
MR-ES/UL
FX1N-40
MT-DSS
FX1N-60
MR-DS
FX1N-60
MR-ES/UL
FX1N-60
MT-DSS
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
40
12–24 V DC
24
16
40
100–240 V AC
24
16
60
12–24 V DC
36
24
60
100–240 V AC
36
24
Output type
Relay
Relay
40
12–24 V DC
24
16
Transistor
(source)
Relay
Relay
60
12–24 V DC
36
24
Transistor
(source)
32
0.65
130x90x75
18
0.65
130x90x75
20
0.8
175x90x75
35
0.8
175x90x75
20
0.8
175x90x75
141265
141266
141267
141268
141269
Power consumption
Weight
Dimensions (WxHxD)
Order information
W 18
kg 0.65
mm 130x90x75
Art. no. 141264
MITSUBISHI ELECTRIC
17
FX BASE UNITS
100-240
VAC
/// BASE UNITS FX1N SERIES
왎 Base Units
¨ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Environmental Specifications
FX BASE UNITS
2
Ambient temperature
0–55 °C (storage temperature: -20–+70 °C)
Protection
IP10
Noise durability
1000 Vpp with noise generator; 1 µs at 30–100 Hz
Dielectric withstand voltage
1,500 V AC, 1 min. (500 V AC for direct voltage modules)
Ambient relative humidity
35–85 % (non-condensing)
Shock resistance
Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)
Vibration resistance
Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting
Insulation resistance
500 V DC, 5 MW
Ground
Class D: Grounding resistance 100 W or less
Fuse rating
AC units: From FX1N-14M첸 to FX1N-24M첸: 250 V AC 1.0 A; From FX1N-40M첸 to FX1N-60M첸: 250 V AC 3.15 A/DC units: 125 V DC 3.15 A
Environment
Avoid environments containing corrosive gases, install in a dust-free location.
Certifications
Please refer to pages 66–67 in this catalogue
Electrical Specifications
Transistor
modules
Type
Power supply
12–24 V DC (+20 %/-15 %)
100–240 V AC (+10 %/-15 %),
50/60 Hz (±10 %)
Inrush current at ON
25 A/1 ms (at 24 V DC);
22 A/0.3 ms (at 12 V DC)
30 A/5 ms (at 100 V AC);
50 A/5 ms (at 200 V AC)
Allowable momentary power
failure time
5 ms
10 ms
Primary power supply
24 V DC, 400 mA
External power supply (24 V DC) —
Switching voltage (max.)
5–30 V DC
- per output
A 2
0.5
- per group
A 8
0.8
Max. switching
current
- inductive load
Response time
400 mA
V <240 V AC, <30 V DC
Max. output
current
Life of contacts (switching times)*
80 VA
ms 10
12 W
<0.2(Y0,Y1<5µs)
3,000,000 at 20 VA; 1,000,000 at 35 VA;
200,000 at 80 VA
* Not guaranteed by Mitsubishi Electric.
Programming Specifications
Program data
Operands
I/O points (addresses)
128 (+4 optional)
Internal relays
1,536
Address range
Max.128 inputs X0–X177,
max. 128 outputs Y0–Y177
Special relays
256
8,000 steps EEPROM (internal), exchangeable
EEPROM for easy program exchange
Step ladder
1,000
Program memory
Timer
256
Cycle period
0.55–0.7 µs /logical instruction
Ext. preset value via potentiometer
2
Number of instructions
27 sequence instructions, 2 step ladder instructions,
89 applied instructions
Counter
235
Programming language
Step ladder, instruction list, SFC
High-speed counter
1 phase, 6 points max: 60kHz/2 points, 10kHz/4 points;
2 phase, 2 points max: 30kHz/1 point, 5kHz/1 point
Program execution
Cyclical execution, refresh mode processing
Real-time clock
Year, month, day, hour, minute, second, weekday
Program protection
Password protection with 3 protection levels*
Data register
8,000
File register
Max. 7,000 (parameter editable),
Total registers = 8,000
Index register
16
Special register
256
Pointer
128
Nestings
8
* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.
18
Interrupt inputs
6
Constants
16 bits: K: -32768 to +32767, hex: 0–FFFF; 32 bits:
K: 2147483648 to +2147483647, hex: 0–FFFF FFFF
MITSUBISHI ELECTRIC
BASE UNITS FX3G SERIES ///
The MELSEC FX3G Series
Add-in function boards can be installed
in the PLC to provide a second RS485/
RS422/RS232 communications
interface for programming or
network configurations.
Analog function boards for input
and output and a function board with
8 analog potentiometers are also
available as add-in.
RAM/EEPROM memory for up to
32,000 PLC program steps gives
you plenty of reserve, even for
big, complex applications.
The base units can be expanded
to provide configurations with up
to 256 inputs and outputs with
modular and compact extension
units.
Integrated real-time
clock with year, month,
day and time
An integrated RUN/STOP switch
is available.
Connection possibility for
special function adaptermodules
Two integrated serial interfaces
for direct communication with
computers.
Two integrated pulse outputs for frequencies
from 2 to 100,000 Hz for controlling stepping
motors and outputting pulse-width modulated signals.
Description of the Unit Components
Terminal cover
Memory cassette, display
module, and expansion
board connector
Terminal protector
Input terminals
Input indicator LEDs
2 analog potentiometers
RUN/STOP switch
Option battery holder
Programming port: RS-422
Programming port: USB
Operation status indicator
LEDs
Expansion bus connector
cover
Output indicator LEDs
Output terminals
Terminal protector
Terminal cover
Flip cover for programming
port, potentiometer and
Run/Stop switch
Protective cover
Top cover
MITSUBISHI ELECTRIC
19
2
FX BASE UNITS
Integrated high-speed counter inputs for
processing fast input signals. For example,
you can configure two 60 kHz counters
and four 10 kHz counters.
Interrupt processing is also handled
via the inputs.
/// BASE UNITS FX3G SERIES
왎 Base Units
¨ FX1S ¨ FX1N þ FX3G ¨ FX3U ¨ FX3UC
Base Units FX3G
The FX3G series base units are available with 14 to 60 input/output
points .
It is possible to choose between relay and transistor output types.
Special features:
앬
앬
앬
앬
앬
앬
앬
앬
Integrated USB interface for communication between PLCs and PC
Integrated serial interface for communication between PCs and HMI
LEDs for indicating the input and output status
Detachable terminal blocks for all units
Slot for memory cassettes
Integrated real-time clock
Integrated positioning control
Exchangeable interface and extension adapters for direct
mounting into a base unit
앬 Expandable with digital I/O modules, special function modules
and ADP modules
앬 User-friendly programming systems, including IEC 1131.3
(EN 61131.3) compatible programming software, HMIs and
hand-held programming units
FX BASE UNITS
2
Base Units with 14–24 I/Os
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
FX3G-14
MR/ES
14
100–240 V AC
8
6
Output type
Relay
Specifications
Power consumption
Weight
Dimensions (WxHxD)
Order information
W 31
kg 0.50
mm 90x90x86
Art. no. 231466
FX3G-14
MT/ESS
14
100–240 V AC
8
6
Transistor
(source)*
31
0.50
90x90x86
FX3G-14
MR/DS
14
24 V DC
8
6
FX3G-24
MR/ES
24
100–240 V AC
14
10
19
0,50
90x90x86
FX3G-14
MT/DSS
14
24 V DC
8
6
Transistor
(source)*
19
0,50
90x90x86
FX3G-24
MR/DS
24
24 V DC
14
10
32
0.55
90x90x86
FX3G-24
MT/ESS
24
100–240 V AC
14
10
Transistor
(source)*
32
0.55
90x90x86
21
0,55
90x90x86
FX3G-24
MT/DSS
24
24 V DC
14
10
Transistor
(source)*
21
0,55
90x90x86
231470
231474
231478
231467
231471
231475
231479
FX3G-40
MT/ESS
40
100–240 V AC
24
16
Transistor
(source)*
37
0.70
130x90x86
FX3G-40
MR/DS
40
24 V DC
24
16
FX3G-60
MR/ES
60
100–240 V AC
36
24
40
0.85
175x90x86
FX3G-60
MT/ESS
60
100–240 V AC
36
24
Transistor
(source)*
40
0.85
175x90x86
FX3G-60
MR/DS
60
24 V DC
36
24
25
0,70
130x90x86
FX3G-40
MT/DSS
40
24 V DC
24
16
Transistor
(source)*
25
0,70
130x90x86
29
0,85
175x90x86
FX3G-60
MT/DSS
60
24 V DC
36
24
Transistor
(source)*
29
0,85
175x90x86
231472
231476
231480
231469
231473
231477
231481
Relay
Relay
Relay
* Sink type transistor output units on request.
Base Units with 40–60 I/Os
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
FX3G-40
MR/ES
40
100–240 V AC
24
16
Output type
Relay
Specifications
Power consumption
Weight
Dimensions (WxHxD)
Order information
W 37
kg 0.70
mm 130x90x86
Art. no. 231468
Relay
Relay
Relay
* Sink type transistor output units on request.
20
MITSUBISHI ELECTRIC
BASE UNITS FX3G SERIES ///
왎 Base Units
¨ FX1S ¨ FX1N þ FX3G ¨ FX3U ¨ FX3UC
Environmental Specifications
0–55 °C (storage temperature: -25–+75 °C)
Protection
IP10
Noise durability
1000 Vpp with noise generator; 1 µs at 30–100 Hz
Dielectric withstand voltage
1500 V AC, 1 min.
2
Ambient relative humidity
5–95 % (non-condensing)
Shock resistance
147m/s2 Acceleration, Action time: 11ms, 3 times by half-sine pulse in each direction X, Y, and Z
Vibration resistance
Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting
Insulation resistance
500 V DC, 5 MW
Ground
Class D: Grounding resistance 100 W or less
Fuse
For FX3G-14M첸 and FX3G-24M첸: 250 V 1 A; For FX3G-40M첸 and FX3G-60M첸: 250 V 3.15 A
Environment
Avoid environments containing corrosive gases, install in a dust-free location.
Certifications
Please refer to pages 66–67 in this catalogue
FX BASE UNITS
Ambient temperature
Electrical Specifications
Transistor
modules
Power supply
100–240 V AC (+10 %/-15 %), 50/60 Hz
Switching voltage (max.)
V <240 V AC, <30 V DC
5–30 V DC
Inrush current at ON
30 A/<5 ms (at 100 V AC);
50 A/<5 ms (at 200 V AC)
Max. output
current
- per output
A 2
0.5
Allowable momentary power
failure time
- per group*
A 8
0.8
10 ms
- inductive load
Primary power supply
—
Max. switching
current
Response time
External power supply (24 V DC) 400 mA
Life of contacts (switching times) �
80 VA
ms 10
12 W
<0.2(<5 µs for Y0,Y1) �
3,000,000 at 20 VA; 1,000,000 at 35 VA;
200,000 at 80 VA
햲
The 40 and 60 I/O points main units supports 5 µs for Y2. 햳 Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and
2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
Programming Specifications
Program data
Operands
I/O points (addresses)
256 total (combined local and CC-Link remote I/O)
Internal relays
Address range
Max. 128 direct addressing and max. 128 remote I/O
Special relays
512
Program memory
32,000 steps EEPROM (internal),
exchangeable EEPROM memory cassette
Step ladder
4096
Cycle period
0.21 µs or 0.42 µs/contact instruction
Number of instructions
29 sequence instructions,
2 step ladder instructions,
123 applied instructions
Programming language
Step ladder, instruction list, SFC
Program execution
Cyclical execution, refresh mode processing
Real-time clock
Year, month, day, hour, minute, second, weekday
2 different keywords,
maximum password length 16 characters
Data register
8.000
Program protection
MITSUBISHI ELECTRIC
7680
Timer
320
Ext. preset value via potentiometer
2
Counter
235
High-speed counter
6 single phase inputs (max. 60 kHz),
3 double phase inputs (max. 30 kHz)
File register
24,000 (ER0~R23999) internal/optional memory
Index register
16
Special register
512 (D8000-D8511)
Pointer
2,048
Nestings
8
Interrupt inputs
6
Constants
16 bits: K: -32,768 to +32,767; hex: 0–FFFF
32 bits: K: 2,147,483,648 to +2,147,483,647;
hex: 0–FFFF FFFF
21
/// BASE UNITS FX3U SERIES
The MELSEC FX3U Series
RAM/EEPROM memory for up to
64,000 PLC program steps gives
you plenty of reserve, even for
big, complex applications.
FX BASE UNITS
2
Add-in function boards can be installed
in the PLC to provide a second RS485 /
RS422 / RS232/USB communications
interface for programming or
network configurations.
for processing
Integrated high-speed counter
fast input signals. For example, you can configure six
100 kHz counters and two 10 kHz counters.
Interrupt processing is also handled via the inputs.
The base units can be expanded
to provide configurations with up
to 384 inputs and outputs with
compact extension units
(total of 384 only by using main
unit I/Os, extension unit I/Os and
remote I/Os).
Integrated real-time
clock with year, month,
days and time
An integrated RUN/STOP
switch is available.
Connection possibility for
special function adapter modules
Integrated serial interface
for direct communication with
computers
Three integrated pulse outputs for frequencies
up to 100 kHz with deceleration and acceleration
ramps for controlling stepping motors and outputting pulse-width modulated signals.
Description of the Unit Components
Battery cover
Protective cover
Terminal block cover
Input terminals
Battery
Installation place for
FX3U-7DM
Expansion board
dummy cover
RUN/STOP switch
LEDs for indicating
the input status
LEDs for indicating the
operating status
Extension device connecting connector cover
LEDs for indicating
the output status
Output terminals
Periphal device
connecting connector
Top cover with Model name
(used, if FX3U-7DM
is not installed)
22
Terminal block cover
Protective cover
MITSUBISHI ELECTRIC
BASE UNITS FX3U SERIES ///
왎 Base Units
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U ¨ FX3UC
Base Units FX3U
The FX3U series base units are available with 16, 32, 48, 64, 80 or
128 input/output points expandable to 384 points.
It is possible to choose between relay and transistor output type.
Note: Additional special versions are available on request.
base unit
LEDs for indicating the input and output status
Slot for memory cassettes
Integrated real-time clock
Expandable with digital I/O modules, special function modules
and ADP modules
앬 User-friendly programming systems, including IEC 1131.3
(EN 61131.3) compatible programming software, HMIs and
hand-held programming units
앬
앬
앬
앬
Base Units with 16 I/Os
FX3U-16
MR/ES
FX3U-16
MT/DSS
FX3U-16
MT/ESS
16
100–240 V AC
8
8
Transistor
(source type)
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
16
24 V DC
8
8
16
100–240 V AC
8
8
Output type
Relay
Relay
16
24 V DC
8
8
Transistor
(source type)
30 VA
0.6
130x90x86
25 W
0.6
130x90x86
30 VA
0.6
130x90x86
231486
231503
231492
FX3U-32
MR/ES
FX3U-32
MT/DSS
FX3U-32
MT/ESS
32
100–240 V AC
16
16
Transistor
(source type)
Power consumption
Weight
Dimensions (WxHxD)
Order information
25 W
kg 0.6
mm 130x90x86
Art. no. 231498
Base Units with 32 I/Os
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
32
24 V DC
16
16
32
100–240 V AC
16
16
Output type
Relay
Relay
32
24 V DC
16
16
Transistor
(source type)
35 VA
0.65
150x90x86
30 W
0.65
150x90x86
35 VA
0.65
150x90x86
231487
231504
231493
Power consumption
Weight
Dimensions (WxHxD)
Order information
30 W
kg 0.65
mm 150x90x86
Art. no. 231499
MITSUBISHI ELECTRIC
23
2
FX BASE UNITS
Special Features:
앬 Integrated serial interface for communication between PCs and HMI
앬 Integrated positioning control
앬 Exchangeable interface modules for direct mounting into a
/// BASE UNITS FX3U SERIES
Base Units with 48 I/Os
FX BASE UNITS
2
FX3U-48
MT/ESS
FX3U-48
MT/DSS
48
24 V DC
24
24
Transistor
(source type)
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
48
24 V DC
24
24
48
100–240 V AC
24
24
Output type
Relay
Relay
48
100–240 V AC
24
24
Transistor
(source type)
40 VA
0.85
182x90x86
40 VA
0.85
182x90x86
35 W
0.85
182x90x86
231488
231494
231505
FX3U-64
MR/ES
FX3U-64
MT/ESS
FX3U-64
MT/DSS
64
24 V DC
32
32
Transistor
(source type)
Power consumption
Weight
Dimensions (WxHxD)
Order information
35 W
kg 0.85
mm 182x90x86
Art. no. 231500
Base Units with 64 I/Os
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
64
24 V DC
32
32
64
100–240 V AC
32
32
Output type
Relay
Relay
64
100–240 V AC
32
32
Transistor
(source type)
45 VA
1.0
220x90x86
45 VA
1.0
220x90x86
40 W
1.0
220x90x86
231489
231495
231506
Power consumption
Weight
Dimensions (WxHxD)
Order information
40 W
kg 1.0
mm 220x90x86
Art. no. 231501
Base Units with 80–128 I/Os
FX3U-80
MR/ES
FX3U-80
MT/DSS
FX3U-80
MT/ESS
FX3U-128
MR/ES
FX3U-128
MT/ESS
80
100–240 V AC
40
40
Transistor
(source type)
128
100–240 V AC
64
64
Relay
128
100–240 V AC
64
64
Transistor
(source type)
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
80
24 V DC
40
40
80
100–240 V AC
40
40
Output type
Relay
Relay
80
24 V DC
40
40
Transistor
(source type)
50 VA
1.20
285x90x86
45 W
1.20
285x90x86
50 VA
1.20
285x90x86
65 VA
1.80
350x90x86
65 VA
1.80
350x90x86
231490
231507
231496
231491
231497
Power consumption
Weight
Dimensions (WxHxD)
Order information
24
45 W
kg 1.20
mm 285x90x86
Art. no. 231502
MITSUBISHI ELECTRIC
BASE UNITS FX3U SERIES ///
왎 Base Units
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U ¨ FX3UC
Environmental Specifications
0–55 °C (storage temperature: -25–+75 °C)
Protection
IP10
Noise durability
1000 Vpp with noise generator; 1 µs at 30–100 Hz
Dielectric withstand voltage
AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.
Ambient relative humidity
5–95 % (non-condensing)
Shock resistance
Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)
2
Vibration resistance
Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting
Insulation resistance
500 V DC, 5 MW
Ground
Class D: Grounding resistance 100 W or less
Fuse
From FX3U-16M첸 to FX3U-32M첸: 3.15 A; From FX3U-48M첸 to FX3U-128M첸: 5 A
Environment
Avoid environments containing corrosive gases, install in a dust-free location.
Certifications
Please refer to pages 66–67 in this catalogue
FX BASE UNITS
Ambient temperature
Electrical Specifications
Transistor
modules
Type
Power supply
24 V DC (+20 %/-30 %)
100–240 V AC (+10 %/-15 %),
50/60 Hz
Switching voltage (max.)
V <240 V AC, <30 V DC
5–30 V DC
Max. output
current
- per output
A 2
0.5 / 0.3햲
- per group*
A 8
0.8/1.6햳
- inductive load
Inrush current at ON
—
30 A/<5 ms (at 100 V AC);
65 A/<5 ms (at 200 V AC)
Allowable momentary power
failure time
5 ms
10 ms
Max. switching
current
Primary power supply
24 V DC
—
Response time
FX3U-16/32MR/ES: 400 mA/
FX3U-48–128MR/ES: 600 mA
External power supply (24 V DC) —
80 VA
ms 10
햴
Life of contacts (switching times)
12 W/7.2 W
<0.2(Y0,Y1<30 µs)
3,000,000 at 20 VA; 1,000,000 at 35 VA;
200,000 at 80 VA
햲
햳
for Y0 and Y1 = 0.3 A; all others 0.5 A
0.8 for 4 per group and 1.6 for 8 per group
Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and
2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
햴
Programming Specifications
Program data
Operands
I/O points (addresses)
Max. total 384 (with remote I/O)
Internal relays
7,680
Address range
Max. 256 direct addressing and
max. 256 network I/Os
Special relays
512
64,000 steps RAM (internal), exchangeable FLROM
for easy program exchange
State relays
4,096
Timer
512
235
Program memory
Cycle period
0.065 µs /basic instruction
Counter
Number of instructions
27 sequence instructions, 2 step ladder instructions,
209 applied instructions
High-speed counter
16
Programming language
Step ladder, instruction list, SFC
High-speed counter speed
1 phase, 8 points max: 100kHz/6 points
10kHz/2 points
2 phase, 2 points max: 50kHz/2 points
Program execution
Cyclical execution, refresh mode processing
Program protection
Password protection with 3 protection levels*
* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.
MITSUBISHI ELECTRIC
Real-time clock
Year, month, day, hour, minute, second, weekday
Data register
8,000
Extension file register
32768
Index register
16
Special register
512
Pointer
4,096
Nestings
8
Interrupt inputs
6
Constants
16 bits: K: -32768 to +32768, hex: 0–FFFF;
32 bits: K: -2147483648 to +2147483647;
hex: 0–FFFF FFFF
25
/// BASE UNITS FX3UC SERIES
The MELSEC FX3UC Series
Integrated RUN/STOP switch
Integrated serial interface
for direct communication
with computers
FX BASE UNITS
2
Interface adapter connection
for
RS485 / RS422 /
RS232
for processing
Integrated high-speed counter
fast input signals. For example, you can configure
six 100 kHz counters and two 10 kHz counters.
Interrupt processing is also handled via the inputs.
RAM/EEPROM memory for up to
64,000 PLC program steps gives
you plenty of reserve, even for
big, complex applications.
The base units can be expanded
to provide configurations with
up to 384 inputs and outputs
with compact extension units
(total of 384 only by using main
unit I/Os, extension unit I/Os
and remote I/Os).
Three integrated pulse outputs for frequencies
up to 100 kHz with deceleration and acceleration
ramps for controlling stepping motors and outputting pulse-width modulated signals.
Description of the Unit Components
RUN/STOP switch
LEDs for indicating the
operating status
Slot for memory cassettes
Memory cassette
(optional)
LEDs for indicating
the input status
LEDs for indicating
the output status
Protective cover for the
extension bus
Extension bus (lateral)
Cover for
adapter module
connection
Connection for
programming units
Back-up battery
Connector for
digital outputs
Battery cover
26
Connector for
digital inputs
MITSUBISHI ELECTRIC
BASE UNITS FX3UC SERIES ///
왎 Base Units
¨ FX1S ¨ FX1N ¨ FX3G ¨ FX3U þ FX3UC
Base Units FX3UC
The FX3U series base units are available with 16, 32, 64 or
128 input/output points (expandable to 384 I/Os).
It is possible to choose between relay and transistor output type.
Special Features:
Integrated serial interface for communication between PCs and HMI
Same instruction set as FX3U
Integrated positioning control
Very compact dimensions
LEDs for indicating the input and output status
Slot for memory cassette
Adapter modules and system cabling sets available for units
with ribbon cable connectors
앬 Expandable with digital I/O modules, special function modules
and ADP modules
앬 User-friendly programming systems, including IEC 1131.3
(EN 61131.3) compatible programming software, HMIs and
hand-held programming units
Base Units with 16–96 I/Os
Integrated inputs/outputs
Power supply
Integrated inputs
Integrated outputs
Output type
Power consumption
Weight
Dimensions (WxHxD)
16
24 V DC (+20 %, -15 %)
8
8
Transistor (source type)*
W 6
kg 0.2
mm 34x90x74
Order information
Art. no. 231508
* Sink type transistor output units on request.
FX3UC-32
MT/DSS
FX3UC-64
MT/DSS
32
24 V DC (+20 %, -15 %)
16
16
Transistor (source type)*
64
24 V DC (+20 %, -15 %)
32
32
Transistor (source type)*
96
24 V DC (+20 %, -15 %)
48
48
Transistor (source type)*
8
0.2
34x90x74
11
0.3
59.7x90x74
14
0.35
85.4x90x74
231509
231510
231511
System Cabling
A choice of terminal blocks with screw or
spring terminals are available for easy wiring
of the FX3UC modules with standard ribbon
cable connectors.
For more details please refer to the
"Accessories" section in this catalogue.
Output terminal block with screw
or spring terminals. It can be fitted
with relay or transistor outputs.
.0
Input terminal block with screw
or spring terminals.
.1
.3
.2
-
24V+
A2-
A2-
24
V
.7
.6
.5
.4
OUT
PLC-V8/FLK14/
Art. 22 95 55 4
A2-
24
V
A2-
24
V
A2-
24
V
A2-
24
V
A2-
24
V
A2-
24
V
24
V
.6 .7
.0 .1 .2 .3 .4 .5
MITSUBISHI ELECTRIC
27
2
FX BASE UNITS
앬
앬
앬
앬
앬
앬
앬
/// BASE UNITS FX3UC SERIES
왎 Base Units
¨ FX1S ¨ FX1N ¨ FX3G ¨ FX3U þ FX3UC
Environmental Specifications
FX BASE UNITS
2
Ambient temperature
0–55 °C (storage temperature: -25–+75 °C)
Protection
IP10
Noise durability
1000 Vpp with noise generator; 1 µs at 30–100 Hz
Dielectric withstand voltage
AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.
Ambient relative humidity
5–95 % (non-condensing)
Shock resistance
Acc. to IEC 68-2-27: 15G (3 times each in 3 directions for 11 ms)
Vibration resistance
Acc. to IEC 68-2-6: 1G (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting
Insulation resistance
500 V DC, 5 MW
Ground
Class D: Grounding resistance 100 W or less
Environment
Avoid environments containing corrosive gases, install in a dust-free location.
Certifications
Please refer to pages 66–67 in this catalogue
Electrical Specifications
Power supply
24 V DC (+20 %/-30 %)
Inrush current at ON
—
Allowable momentary power
failure time
5 ms
Primary power supply
24 V DC
Switching voltage (max.)
V 5–30 V DC
Max. output
current
- per output
A 0.1/0.3 햲
- per group*
A 0.8/1.6
Max. switching
current
- inductive load
Response time
External power supply (24 V DC) —
2.4 W/7.2 W 햳
ms <0.2 (Y0,Y1<30 µs)
햴햴
Life of contacts (switching times)
3,000,000 at 20 VA; 1,000,000 at 35 VA;
200,000 at 80 VA
햲
햳
for Y0 and Y1 = 0.3 A; all others 0.1 A
7.2 W for Y0 to Y3, all other outputs 2.4 W
Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and
2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
햴
Programming Specifications
Program data
Operands
I/O points (addresses)
Max. total 384 (with remote I/O)
Internal relays
7,680
Address range
Max. 256 direct addressing and
max. 256 network I/Os
Special relays
512
64,000 steps RAM (internal), exchangeable FLROM
for easy program exchange
State relays
4,096
Timer
512
235
Program memory
Cycle period
0.065 µs/basic instruction
Counter
Number of instructions
27 sequence instructions, 2 step ladder instructions,
209 applied instructions
High-speed counter
16
Programming language
Step ladder, instruction list, SFC
High-speed counter speed
1 phase, 8 points max: 100 kHz/6 points
10 kHz/2 points
2 phase, 2 points max: 50 kHz/2 points
Program execution
Cyclical execution, refresh mode processing
Program protection
Password protection with 3 protection levels*
* Protection levels may only be changed with FX-30P.
28
Real-time clock
Year, month, day, hour, minute, second, weekday
Data register
8,000
Extension file register
32768
Index register
16
Special register
512
Pointer
4,096
Nestings
8
Interrupt inputs
6
Constants
16 bits: K: -32768 to +32768, hex: 0–FFFF;
32 bits: K: -2147483648 to +2147483647;
hex: 0–FFFF FFFF
MITSUBISHI ELECTRIC
COMPACT EXTENSION UNITS ///
왎 Powered Compact Extension Units
¨ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Extension Units FX0N
The FX0N series extension units are available with 40 input/
output points.
It is possible to choose between relay and transistor output type.
Special Features:
앬 LEDs for indicating the input and output status
앬 MELSEC FX1N series compatible
앬 Integrated service power supply with up to 200 mA capacity
EXTENSION MODULES
3
Electrical data
Integrated inputs/outputs
AC range (+10 %, -15 %)
Power
Frequency at AC
supply
DC range (+20 %, -15 %)
Max. input apparent power
100 V AC
Inrush
current at ON 200 V AC
24 V DC
Allowable momentary power
failure time
External service power supply (24 V DC)
Inputs
Integrated inputs
Min. current for logical 1
Max. current for logical 0
Response time
Outputs
Integrated outputs
Output type
Max. switching voltage
Max. output - per output
current
- per group*
Max. switching - inductive load
power
Response time
Life of contacts (switching times) 햳
Mechanical data
Weight
Dimensions (WxHxD)
Order information
FX0N-40
ER-DS
FX0N-40
ET-DSS
40
100–240 V
Hz 50/60
—
40 VA
30 A/5 ms
50 A/5 ms
—
40
—
—
24 V
20 W
—
—
60 A/50 ms
40
—
—
24 V
30 W
—
—
60 A/50 ms
ms 10
5
5
mA 200
—
—
24
24
mA 3.5
3.5
mA 1.5
1.5
For all extension units of the MELSEC FX0N series: 10 ms (at time of shipment)
16
16
Relay
Relay
Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
A 2
2
A 5
5
VA 80
80
24
3.5
1.5
16
Transistor
0.5
0.8 햲
12
ms 10
10
<0.2
For all extension units of the MELSEC FX0N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (only for relay output)
kg 0.75
mm 150x90x87
Art. no. 60012
0.75
150x90x87
0.75
150x90x87
55955
55954
햲
0.8 for 4 per group
Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
햳
MITSUBISHI ELECTRIC
29
/// COMPACT EXTENSION UNITS
왎 Powered Compact Extension Units
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
Extension Units FX2N
The FX2N series extension units are available with 32 or
48 input/output points.
It is possible to choose between relay and transistor output type.
Special Features:
앬
앬
앬
앬
LEDs for indicating the input and output status
MELSEC FX1N/FX3G and FX3U series compatible
Detachable terminal blocks
Integrated service power supply with 250 mA or 460 mA
EXTENSION MODULES
3
Electrical data
Integrated inputs/outputs
AC range (+10 %, -15 %)
Power
frequency at AC
supply
DC range (+20 %, -30 %)
Max. input apparent power
100 V AC
Inrush
current at ON 200 V AC
Allowable momentary power
failure time
External service power supply (24 V DC)
Power supply int. bus (5 V DC)
Inputs
Integrated inputs
Min. current for logical 1
Max. current for logical 0
Response time
Outputs
Integrated outputs
Output type
Switching voltage (max.)
Max. output - per output
current
- per group *
Max. switching - inductive load
power
Response time
Life of contacts (switching times) 햲
Mechanical data
Weight
Dimensions (WxHxD)
Order information
FX2N-32
ET-ESS/UL
FX2N-48
ER-DS
FX2N-48
ER-ES/UL
FX2N-48
ET-DSS
FX2N-48
ET-ESS/UL
32
100–240 V
Hz 50/60
—
35 VA
40 A <5 ms
60 A <5 ms
32
100–240 V
50/60
—
35 VA
40 A <5 ms
—
48
—
—
24 V
30 W
—
—
48
100–240 V
50/60
—
45 VA
40 A <5 ms
60 A <5 ms
48
—
—
24 V
30 W
40 A < 5 ms
60 A < 5 ms
48
100–240 V
50/60
—
45 VA
40 A <5 ms
60 A <5 ms
ms 10
10
5
10
5
10
mA 250
mA 690
250
690
—
690
460
690
—
690
460
690
16
16
24
24
mA 3.5
3.5
3.5
3.5
mA 1.5
1.5
1.5
1.5
For all extension units of the MELSEC FX2N series: 10 ms (at time of shipment)
24
3.5
1.5
24
3.5
1.5
16
24
24
Transistor
Relay
Relay
(source)
Generally for relay version: <264 V AC, <30 V DC; for transistor version: 5–30 V DC
A 2
0.5
2
2
A 8
0.8/1.6 햳
8
8
24
Transistor
(source)
24
Transistor
(source)
0.5
0.8/1.6 햳
0.5
0.8/1.6 햳
W 80
12
12
16
Relay
12
80
80
ms 10
<0.2
10
10
<0.2
For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
kg 0.65
mm 150x90x87
Art. no. 65568
<0.2
0.65
150x90x87
0.85
182x90x87
0.85
182x90x87
0.85
182x90x87
0.85
182x90x87
65569
66633
65571
66634
65572
햲
햳
Not guaranteed by Mitsubishi Electric
0.8 for 4 per group and 1.6 for 8 per group
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
30
MITSUBISHI ELECTRIC
MODULAR EXTENSION UNITS ///
왎 Unpowered Modular Extension Blocks
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
Extension Blocks FX2N
The FX2N series modular extension blocks are available with
8 or 16 input/output points.
It is possible to choose between relay and transistor output type.
Special Features:
앬
앬
앬
앬
2
IN
OUT
LEDs for indicating the input and output status
MELSEC FX1N/FX3G and FX3U series compatible
Very compact dimensions
Vertically terminal blocks with a cable guide to the upper or
lower side
EXTENSION MODULES
3
FX2N-8EX-ES
OUT
FX2N-16EYR-ES/UL
FX2N-8
EX-ES/UL
Electrical data
Integrated inputs/outputs
Nbr. of occupied I/O points in the PLC
Power supply
Inputs
Integrated inputs
Min. current for logical 1
Max. current for logical 0
Response time
Outputs
Integrated outputs
Output type
Max. switching voltage
Max. output - per output
current
- per group 햲
Max. switching - inductive load
power
Response time
Life of contacts (switching times) 햳
Mechanical data
Weight
Dimensions (WxHxD)
Order information
햲
햳
FX2N-8
EYR-ES/UL
8
8
8
16
8
8
All modular extension blocks are supplied by the base unit.
FX2N-8
EYT-ESS/UL
8
8
4
8
—
—
mA 3.5
3.5
—
—
mA 1.5
1.5
—
—
For all extension blocks of the MELSEC FX2N series: 10 ms (at time of shipment)
FX2N-16
EYR-ES/UL
FX2N-16
EYT-ESS/UL
16
16
16
16
16
16
16
3.5
1.5
—
—
—
—
—
—
4
—
8
8
—
16
Relay
—
Relay
Transistor
—
Relay
16
Transistor
(source)
—
—
2
8
0.5
1.6
—
80
12
Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
A 2
—
2
0.5
A 8
—
8
0.8
VA 80
—
80
12
ms 10
10
10
<0.2
—
10
For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
kg 0.2
mm 43x90x87
Art. no. 166285
<0.2
0.2
43x90x87
0.2
43x90x87
0.2
43x90x87
0.3
40x90x87
0.3
40x90x87
0.3
40x90x87
166284
166286
166287
65776
65580
65581
This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
Not guaranteed by Mitsubishi Electric
MITSUBISHI ELECTRIC
31
/// MODULAR EXTENSION UNITS
왎 Modular Extension Units
¨ FX1S ¨ FX1N ¨ FX3G ¨ FX3U þ FX3UC
Extension Units FX2NC
The modular extension units of the FX2NC series can be used in
combination with FX3UC series base units only. They are available
with 16 or 32 input/output points. For modules with 16 outputs it
is possible to choose between relay and transistor output type.
FX2NC-32EX
-DS
POWER
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
Note: These modules can be used in combination with a FX3UC PLC only!
Special Features:
앬 Very compact dimensions
앬 LEDs for indicating the input and output status
앬 Removable terminal blocks for FX2NC-16EYR-T-DS and
FX2NC-16EYR-T-DS
FX2NC-16EX-T-DS (interchangeable against optional spring
terminal blocks)
앬 Adapter modules and system cabling sets are optionally available for units with ribbon cable connectors (transistor output
types)
PW
Y0
1
2
3
Y4
5
6
7
Y0
1
2
3
Y4
5
6
7
EXTENSION MODULES
3
FX2NC-32EX-DS
FX2NC-16EYR-DS
Electrical data
Integrated inputs/outputs
Power supply
Inputs
Integrated inputs
Input current X0®X7 / X10®¥
Min. current for logical 1
X0®X7 / X10®¥
Max. current for logical 0
Isolation
Response time
Outputs
Integrated outputs
Output type
Max. switching voltage
- per output
Max. output
current
- per group*
Max. switching - inductive load
power
- lamp load
Response time
Life of contacts (switching times)
Mechanical data
Connection type
Weight
Dimensions (WxHxD)
FX2NC-32
EX-DS
FX2NC-32
EYT-DSS
16
16
16
All modular extension blocks are supplied by the base unit.
16
32
32
16
7/5
mA 4.5/3.5
—
—
16
7/5
—
—
32
7/5
—
—
—
4.5/3.5
—
4.5/3.5
—
mA 1.5
—
1.5
—
1.5
—
Photocoupler isolation between input terminals and PC power for all base units
For all extension units of the MELSEC FX2NC series: 10 ms (at time of shipment), partly adjustable between 0 and 60 ms in 1 ms steps (REFF, FNC51 = 0–60 ms)
V
A
A
VA
W
ms
—
16
—
16
—
Relay
—
Transistor
Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
—
2
—
0.1/0.3 햲
—
4/8
—
0.8
—
80
—
2.4/7.2 햳
—
100
—
0.3/0.9 햴
—
10
—
<0.2
—
like base unit
—
—
Removable screw terminal blocks
kg 0.2
0.2
mm 20.2x90x89
24.2x90x89
Order information
Art. no. 128152
햲
햳
128153
—
—
32
Transistor
—
—
—
—
—
—
0.1/0.3 햲
0.8
2.4/7.2 햳
0.3/0.9 햴
<0.2
—
Ribbon cable connector
0.15
14.6x90x87
Ribbon cable connector Ribbon cable connector
0.2
0.2
14.6x90x87
26.2x90x87
Ribbon cable connector
0.2
26.2x90x87
104503
104504
104506
104505
햴
0.3A for Y0 to Y1; 0.1 A all others
7.2 W for Y0 to Y3; 2.4 W all others
0.9 W for Y0 to Y3; 0.3 W all others
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
32
MITSUBISHI ELECTRIC
ANALOG MODULES ///
왎 Analog Output Modules
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
FX2N-2DA, FX2N-4DA, FX3U-4DA
The analog output modules provide the user with 2 to 4 analog outputs. The modules
convert digital values from the FX1N/FX3G/FX3U controller to the analog signals required
by the process. The module can output both current and voltage signals.
Note: The FX3U-4DA can only be used in combination with a FX3G/FX3U series base unit.
Analog output range
FX3U -4DA
FX2N-2DA
voltage
current
Fullscale overall accuracy
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Resolution
24 V
D/A
FX3U-4DA
Order information
—
2
0 –+10 V DC/
0–+5 V DC/
4–+20 mA
2.5 mV (12 bits)
4 µA (12 bits)
±1 %
30 mA (from base unit)
85 mA
8
kg 0.3
mm 43x90x87
Art. no. 102868
FX2N-4DA
—
4
-10 –+10 V DC/
0 –+20 mA/
4–+20 mA
5 mV (10 bits)
20 µA (11 bits + sign)
±1 %
30 mA (from base unit)
200 mA
8
0.3
55x90x87
FX3U-4DA
—
4
-10 –+10 V DC/
0 –+20 mA/
4–+20 mA
0.32 mV (16 bits +sign)
0.63 µA (15 bits)
±0.3–0.5 %*
100 mA (from base unit)
160 mA
8
0.2
55x90x87
65586
169509
4
* Dependent on the ambient temperature
왎 Analog Input Modules
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
FX2N-2AD, FX2N-4AD, FX3U-4AD, FX2N-8AD
The analog input modules provide the user with 2 to 8 analog inputs. The module
converts analog process signals into digital values which are further processed by the
MELSEC FX1N/FX3G/FX3U controller.
The actual values or mean values over several measurements may be output.
FX 2N -2AD
Note: The FX3U-4AD can only be used in combination with a FX3G/FX3U series base unit.
POWER
Analog channels
inputs
outputs
Analog input range
voltage
Resolution
current
Fullscale overall accuracy
5 V DC
Power supply
24 V DC
MITSUBISHI
FX2N-8AD
POWER
24V
Related I/O points
Weight
Dimensions (WxHxD)
Order information
FX2N-4AD
4
—
-10–+10 V DC/
-20–+20 mA/
4–+20 mA
5 mV
2.5mV, 1.25mV/ (11 bits + sign)
4 µA (12 bits)
20 µA
(10 bits + sign)
±1 %
±1 %
20 mA
30 mA
(from base unit) (from base unit)
50 mA
(from base unit) 55 mA
8
8
kg 0.3
0.3
mm 43x90x87
55x90x87
2
—
0 –+10 V DC/
0–+5 V DC/
0/ 4–+20 mA
Art. no. 102869
65585
FX3U-4AD
4
—
-10 –+10 V DC/
-20–+20 mA/
4–+20 mA
0.32 mV
(16 bits + sign)
1.25 µA
(15 bits + sign)
±0.3–1 %*
110 mA
(from base unit)
FX3UC-4AD
4
—
-10–+10 V DC/
-20–+20 mA/
4–+20 mA
0.32 mV
(16 bits + sign)
1.25 µA
(15 bits + sign)
±0.3–1 %*
100 mA
(from base unit)
FX2N-8AD
8
—
-10 –+10 V DC/
-20–+20 mA/
4–+20 mA
0.63 mV
(14 bits + sign)
2.5 µA
(13 bits + sign)
±0.3–0.5 %*
50 mA
(from base unit)
90 mA
80 mA
80 mA
8
0.2
55x90x87
8
0.13
20.2x90x79
8
0.4
75x105x75
169508
210090
129195
*Dependent on the ambient temperature
Note: The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type
thermocouples.
MITSUBISHI ELECTRIC
33
SPECIAL FUNCTION MODULES
Analog channels
inputs
outputs
/// ANALOG MODULES
왎 Combined Analog I/O Modules
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
FX0N-3A, FX2N-5A, FX3U-3A-ADP
The analog input/output modules are available in two different models. They provide the
user with 2 or 4 analog inputs and 1 analog output. They serve for conversion of analog
process signals into digital values, and vice versa.
As of the FX2N-5A module the analog inputs can be selected between current or voltage
input signals.
Note: The FX2N-5A may not be used in combination with a FX1N series base unit.
Number of
analog points
FX2N -5A
FX0N-3A
24 V
SPECIAL FUNCTION MODULES
4
voltage
2
1
0–+10 V (8 bit),
0–+5 V (8 bit)
current
0/4–+20 mA (8 bit)
Input (resolution)
AD / DA
FX2N-5A
inputs
outputs
Output (resolution)
voltage
current
Total accuracy
Power supply
5 V DC
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
0–+10 V (8 bit),
0–+5 V (8 bit)
4–+20 mA (8 bit)
±1 %
30 mA (from base unit)
90 mA (from base unit)
8
kg 0.2
mm 43x90x87
Art. no. 41790
FX2N-5A
4
1
-10–+10 V (15 bit + sign),
-100–+100 mV (11 bit + sign)
-20–+20 mA (14 bit + sign),
0/4–+20 mA (14 bit)
FX3U-3A-ADP
2
1
-10–+10 V (12 bit)
0–+10 V (2.5 mV/12 bit))
0/4–+20 mA (10 bit)
±0.3–1 %*
70 mA (from base unit)
90 mA
8
0.3
55x90x87
4–+20 mA (4 µA/12 bit)
±0.5–1 %*
20 mA (from base unit)
90 mA
0
0.1
17.6x90x89.5
153740
221549
0–+10 V (2.5 mV/12 bit)
4–+20 mA (5 µA/12 bit)
*Dependent on the ambient temperature
왎 Analog Temperature Input Modules
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
FX2N-4AD-TC, FX2N-4AD-PT, FX2N-2LC
The analog input module for thermocouples FX2N-4AD-TC is used for processing temperatures. It has 4 independent inputs for detecting signals from thermocouples of types J
and K. The type of thermocouple can be chosen independently for each point.
The analog input module for Pt100 inputs FX2N-4AD-PT permits the connection of four
Pt100 sensors to the FX2N/FX3U series controller.
The temperature control module FX2N-2LC is equipped with two temperature input
points and two transistor (open collector) output points. It is used to read temperature
signals from thermocouples and Pt100 sensors, and performs PID output control
FX2N -4AD-TC
Note: The FX2N-2LC may not be used in combination with a FX1N series base unit.
A/D
Analog inputs
Compensated temperature range
Digital outputs
Resolution
Total accuracy
Power supply
Related I/O points
Weight
Dimensions (WxHxD)
Order information
34
4 (J or K type)
(J type)/
°C -100–+600
-100–+1200 (K type)
-1000–+6000 (J type)/
-1000–+12000 (K type)
0.3 (J type) / 0.4 (K type)
±0.5 % fullscale +1 °C
5 V DC
24 V DC
40 mA (from base unit)
60 mA
8
kg 0.3
mm 55x90x87
Art. no. 65588
FX2N-4AD-PT
4 (Pt100 sensors)
-100–+600
-1,000–6,000
(12 bit conversion)
0.2–0.3 °C
FX2N-2LC
2 points
Thermocouple and
Pt100 sensor
2 transistor output points
30 mA (from base unit)
50 mA
8
0.3
55x90x87
0.1 °C or 1 °C
±0.7 % fullscale
(±0.3 % when ambient temperature is 23 °C ±5 °C)
70 mA (from base unit)
55 mA
8
0.3
55x90x87
65587
129196
±1. 0 % fullscale
MITSUBISHI ELECTRIC
ANALOG MODULES ///
왎 Analog Temperature Input Adapters
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
FX3U-4AD-TC-ADP, FX3U-4AD-PT-ADP, FX3U-4AD-PTW-ADP, FX3U-4AD-PNK-ADP
FX3U -4AD-TC-ADP
L1+
J-type
•ú
•ú
24-
24+
POWER
L2+
L1-
FX3U -4AD-PT-ADP
L3+
L2-
POWER
The analog input adapter for thermocouples FX3U-4AD-TC-ADP is used for processing
temperatures. It has 4 independent inputs for detecting signals from thermocouples of
types J and K.
The FX3U-4AD-PNK-ADP analog input adapter enables the connection of up to four
Pt1000/Ni1000 thermocouples.
The FX3U-4AD-PT-ADP and FX3U-4AD-PTW-ADP analog input adapters enable the
connection of up to four Pt100 thermocouples to the PLC system.
All analog adapters can be used in combination with the base units of the
FX3G/FX3U/FX3UC series only.
L2+
L1-
L1+
J-type
•ú
•ú
L4-
L4+
24-
L3-
24+
Note: When connecting the analog adapters to a FX3U base unit, a communications adapter is required.
A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.
When connecting an adapter to a FX3G PLC the communications adapter FX3G-CNV-ADP is required.
0.1
0.2–0.3
0.1
±0.5–1.0 % fullscale*
15 mA (from base unit)
50 mA
0
0.1
15 mA (from base unit)
50 mA
0
0.1
15 mA (from base unit)
45 mA
0
0.1
165272
214173
214172
L4-
L4+
L3-
-500–+2500
FX3U-4AD-PTW-ADP FX3U-4AD-PNK-ADP
4 (Pt100 sensors,
(Pt1000/Ni1000
3-wire)
sensors, 2/3 wire)
-50–+250 (Pt1000)/
-100–+600
-40–+110 (Ni1000)
-500–+2500 (Pt1000)/
-1000–+6000
-400–+1100 (Ni1000)
FX3U-4AD-PT-ADP
Analog inputs
4 (J or K type)
4 (Pt100 sensors)
Compensated temperature
range
-100–+600 (J type)/
-100–+1000 (K type)
-1000–+6000(Jtype)/
-1000–+10000(Ktype)
0.3 (J type)/
0.4 (K type)
±0.5 % fullscale
15 mA (from base unit)
45 mA
0
0.1
17.6x90 (106)x89.5
-50–+250
°C
Digital outputs
Resolution
°C
Total accuracy
Power supply
5 V DC
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
kg
mm
Order information
Art. no. 165273
*Dependent on the ambient temperature
왎 Analog I/O Adapters
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
FX3U-4AD-ADP, FX3U-4DA-ADP
The FX3U-4AD-ADP adapter module for analog input is a special function adapter to add
four analog input points to the FX3G/FX3U/FX3UC PLC system.
The FX3U-4DA-ADP adapter module for analog output is a special function adapter to add
four analog output points to the FX3G/FX3U/FX3UC PLC system.
Note: When connecting the analog adapters to a FX3U base unit, a communications adapter is required.
A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.
When connecting an adapter to a FX3G PLC the communications adapter FX3G-CNV-ADP is required.
FX3U -4DA-ADP
Analog channels
inputs
outputs
V3+
COM2
I2+
V2+
COM1
I1+
V1+
24-
24+
POWER
COM4
I4+
V4+
COM3
I3+
FX3U-4AD-ADP
Analog range
Resolution
Overall accuracy
FX3U-4DA-ADP
Power supply
Related I/O points
Weight
Dimensions (WxHxD)
Order information
5 V DC
24 V DC
4
—
0–+10 V DC, 4–+20 mA
2.5 mV/10 µA (12 bit/11 bit )
±0.5 %*/±1 %
15 mA (from base unit)
40 mA
0
kg 0.1
mm 17.6x90 (106)x89.5
Art. no. 165241
—
4
0–+10 V DC, 4–+20 mA
2.5 mV/4 µA (12 bit)
±0.5 %*/±1 %
15 mA (from base unit)
150 mA
0
0.1
17.6x90 (106)x89.5
165271
*Dependent on the ambient temperature and signal quality
MITSUBISHI ELECTRIC
35
4
SPECIAL FUNCTION MODULES
L2-
FX3U-4AD-PT-ADP
L3+
FX3U-4AD-TC-ADP
/// TEMPERATURE CONTROL/DATA LOGGER
왎 Temperature Control Module
¨ FX1S ¨ FX1N þ FX3G þ FX3U þ FX3UC
Temperature control module
24 V
OUT1
OUT2
OUT3
OUT4
The temperature control module FX3U-4LC
is equipped with four temperature input
points and four transistor (open collector)
output points. It is used to read temperature signals from thermocouples and Pt100
sensors, and performs PID output control.
The proportional band, the integral time
and the derivative time can be easily set by
auto tuning.
The channels are isolated against each
other.
FX3U -4LC
Analog inputs
Compensated temperature
range
Digital outputs
Resolution
Total accuracy
5 V DC
Power supply
24 V DC
Related I/O points
Dimensions (WxHxD)
SPECIAL FUNCTION MODULES
4
Order information
4 (Thermocouple and Pt100 sensors)
°C -200 to +2300
4 NPN transistor open collector output points
°C 0.1 or 1
±0.3 to 0.7 % (fullscale, dependent on the ambient temperature)
160 mA (from base unit)
50 mA
8
mm 90x90x86
Art. no. 232806
왎 Data Logger Module
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
Data logger module
FX3U-CF-ADP
POWER
BUFFER
ERR.
CF CARD
FULL
ACCESS
ON
ACCESS
SLOT
OFF
The FX3U-CF-ADP is a general purpose
data logging adapter. The difference to
other available logging units is that the PLC
main unit controls the data logging based
on user requirements, e.g. periodical or
even based. For tracing a timestamp is
automatically added to all data storages,
that eases alarm and other time critical log-
Data access method
Connectable units
Time stamp function
Recommended storage media
Max. file size
File format
Max. numbers of files
FIFO function
Power supply
24 V DC
Related I/O points
Dimensions (WxHxD)
mm
Order information
36
ging. Another usage is the storage of bigger recipe data. A CompactFlash쏐 memory
card up to 2GB can be used. Six applied
instructions allow all kinds of data writing,
manipulation or reading, making this
adapter the optimum solution towards
customer requirements.
Controlled by the main unit, no polling from the logging unit possible.
A maximum of one FX3U-CF-ADP can be connected per PLC.
The real time clock data of the base unit is used.
CompactFlash쏐 memory card (GT05-MEM-256MC, -512MC,-1GC, -2GC)
512 MB
CSV
63 (Plus one FIFO file.)
One pattern (The file name gets automatically generated.)
130 mA
0
45x90x89.5
Art. no. 230104
MITSUBISHI ELECTRIC
HIGH SPEED COUNTER ///
왎 High-Speed Counter Modules
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
FX2N-1HC, FX2NC-1HC
In addition to the internal high-speed MELSEC FX counters, the high-speed counter modules FX2N-1HC and FX2Nc-1HC provide the user with an external counter. It counts 1- or
2-phase pulses up to a frequency of 50 kHz. The counting range covers either 16 or 32 bit.
The two integrated transistor outputs can be switched independently of one another by
means of internal comparison functions. Hence, simple positioning tasks can also be realized economically. In addition, the FX2N-1HC and FX2Nc-1HC can be used as a ring counter.
FX2N -1HC
kHz
bit
16 bit
32 bit
Counting range
Output type
Power supply
5 V DC
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
kg
mm
Order information
5, 12, 24 V DC/7 mA
2 (1 phase) or 1 (2 phase)
50
16, 32
Up/down counter, ring counter
0–65535
-2147483648–+2147483647
2 x transistor (5–24 V DC; 0.5 A)
90 mA (from base unit)
—
8
0.3
55x90x87
5, 12, 24 V DC/7 mA
2 (1 phase) or 1 (2 phase)
50
16, 32
Up/down counter, ring counter
0–65535
-2147483648–+2147483647
2 x transistor (5–24 V DC; 0.5 A)
90 mA (from base unit)
—
8
0.13
20.2x90x89
Art. no. 65584
왎 High-Speed Counter Adapters
4
217916
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
FX3U-4HSX-ADP, FX3U-2HSY-ADP, FX3U-2HC
These adapter modules allow direct processing of positioning application data.
The FX3U-4HSX-ADP and the FX3U-2HC provide high speed counter inputs up to 200 kHz
while the FX3U-2HSY-ADP delivers 2 channels of pulse train outputs up to 200 kHz.
FX3U-2HSX-ADP
Note: The adapters FX3U-첸-ADP can only be used with the FX3U and they require a function extension
board.
POWER
X0/3 X2/5
X1/4
+
-
X0/3
+
X1/4 X6/7
X2/5
+
-
FX3U -2HSY-ADP
Counter
+
Y4/6 Y5/7
SG SG
X6/7
-
-
POWER
Y0/2 Y1/3
FP.RP
inputs
outputs
-Y4/6 +
-Y0/2 +
PLS DIR
Max. counting
frequency
inputs
outputs
Input format
SGB
- Y5/7 +
- Y1/3 +
SGA
FX3U-4HSX-ADP
Output format
4
—
1 ch 1 input or
kHz 1 ch 2 inputs: 200
2 ch 2 inputs: 100
kHz —
Differential line receiver
(AM26C32 is suitable)
Photocoupler isolation on
inputs
—
FX3U-2HSY-ADP
Maximum cable length
Input potential
Output load
Maximum connectivity
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
MITSUBISHI ELECTRIC
m 10
5 V DC
—
2
30 mA (from base unit)
30 mA (from base unit)
0
kg 0.08
mm 17.6x90 (106)x89.5
Art. no. 165274
FX3U-2HSY-ADP
—
2
FX3U-2HC
2
—
—
1 phase input: 200
2 phase input: 200/100/50
200
Differential line driver
(AM26C31 is suitable)
Normal rotation pulse train,
reverse pulse train or pulse
train + one
10
—
less than 25 mA
2
30 mA (from base unit)
60 mA (from base unit)
0
0.08
17.6x90 (106)x89.5
—
Differential line receiver
(AM26C32 is suitable)
Photocoupler isolation on
inputs
Transistor output, 5–24 V DC
When the counter value coincides with an output compare
value, the appropriate output
is set ON.
10
5/12/24 V DC
0.5 A
8
245 mA (from base unit)
—
8
0.08
55x90x87
165275
232805
—
37
SPECIAL FUNCTION MODULES
Signal level
Counter inputs
Max. counting frequency
Input format
Type of counter
/// POSITIONING MODULES
왎 Positioning Modules
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
FX2N-1PG-E, FX2N-10PG
POWER
ERROR
FX 2N -10PG
START
DOG
X0
X1
øA
øB
PGO
FP
RP
CLR
The positioning modules FX2N-1PG-E and FX2N-10PG are extremely efficient single-axis
positioning modules for controlling either step drives or servo drives (by external regulator) with a pulse chain. They are very suitable for achieving accurate positioning in combination with the MELSEC FX series. The configuration and allocation of the position data
are carried out directly via the PLC program. A very wide range of manual and automatic
functions are available to the user.
FX2N-10PG
Accessible axes
1
Output frequency
pulse/s 10–100 000
Signal level for digital inputs
Power supply
5 V DC/100 mA; 24 V DC/70 mA
5 V DC
55 mA (from base unit)
120 mA (from base unit)
24 V DC
—
—
8
8
Weight
Dimensions (WxHxD)
Order information
SPECIAL FUNCTION MODULES
1–1 000 000
24 V DC/40 mA
Related I/O points
4
1
왎 Positioning Module for SSCNET
kg 0.3
0.2
mm 43x90x87
43x90x87
Art. no. 65583
140113
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
SSCNET III Module FX3U-20SSC-H
INT 0
INT 1
A
B
START
DOG
INT 0
INT 1
A
B
X READY
Y READY
X ERROR
Y ERROR
POWER
The SSCNET module FX3U-20SSC-H can be used in combination with a FX3U programmable controller to achieve a cost effective solution for high precision, high speed positioning. The plug-and-play fiber optic SSCNET cabling reduces setup time and increases control distance for positioning operations in a wide range of applications.
Servo parameters and positioning information for the FX3U-20SSC-H are easily set up with
an FX3U base unit and a personal computer. For parameter setting, monitoring and testing
the easy programming software FX Configurator-FP is available.
Note: the FX3U-20SSC-H can be used in combination with a FX3U- or FX3UC base unit only. Please refer to
the Mitsubishi Electric MELSERVO catalog for suitable servo motors and amplifiers.
FX2CU-20SSC-H
Accessible axes
Output frequency
Pulse output format
Communications speed
Starting time
Max. to PLC connectable modules
Status displays
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
38
2 (independent or interpolation)
1 Hz to 50 MHz
SSCNET III (servo bus)
50 Mbps
ms 1.6 (+1.7 SSCNET cycle time)
Up to 8 can be connected to the FX3U PLC
Power, module status, axis status, error
100 mA
—
8
kg 0.3
mm 55x90x87
Art. no. 168914
MITSUBISHI ELECTRIC
NETWORK MODULES ///
왎 Network Modules for CC-Link
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
CC-Link Master Module FX2N-16CCL-M
The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the machine.
The CC-Link master module FX2N-16CCL-M is a special extension block which assigns an
FX series PLC as the master station of the CC-Link system.
The setting of all modules within the network is handled directly via the master module.
Up to 15 remote stations and remote device stations can be connected to the master station as decentralized I/O stations. These remote stations can be up to 7 I/O modules and
up to 8 remote device stations. 2 master modules can be connected to one FX1N, FX3G or
FX3U/FX3UC base unit.
The maximum communications distance is 1200 m without repeater.
RUN
ERR.
MST
TEST 1
TEST 2
L RUN
L ERR.
CC-LINK
FX2n-16CCL-M
SW
M/S
PRM
TIME
LINE
Note: When connecting this module to a FX3UC base unit, the communications adapter FX2N-CNV-IF
resp. a power supply unit FX3UC-1PS-5V is required. For more informations about CC-Link please refer to
the "Automation Book".
SD
RD
Link points per station
Max. number of I/O points
Number of connectable modules
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
4
Master station
I/O points 32
register 8
128 (with FX1N PLC), 256 (with FX3G PLC)*, 384 (with FX3U PLC)*
Max. 15
—
150 mA
8
0.4
85x90x87
Order information
SPECIAL FUNCTION MODULES
Module type
Art. no. 133596
*Including I/O points in PLC and network.
FX3U-64CCL Interface Block
RUN
ERR.
L RUN
L ERR.
SD
RD
The FX3U-64CCL CC-Link interface block is available for FX3 series main units and enables
CC-Link V2 functionality, for example expanded cyclic transmission which facilitates handling of multiple data processes.
Note: When attaching the FX3U-64CCL to an FX3UC main unit, the FX2NC-CNV-IF interface converter or
the FX3UC-1PS-5V power supply unit is required. For more informations about CC-Link please refer to the
"Automation Book".
POWER
Module type
FX3U-64CCL
Link points per station
Max. transmission speed
Related I/O points
Power supply
Weight
Dimensions (WxHxD)
Order information
MITSUBISHI ELECTRIC
Intelligent device station
I/O points 128 (Occupying 1 station with Octuple expanded cyclic setting)
register 32 (Occupying 1 station with Octuple expanded cyclic setting)
10 Mbps
8
24 V DC/220 mA
0.3
55x90x87
Art. no. 217915
39
/// NETWORK MODULES
왎 Network Modules for CC-Link
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
CC-Link Communication Module FX2N-32CCL
The communication module FX2N-32CCL enables the user to connect to the CC-Link
network with a superior PLC system as master CPU. This gives him access to the network
of all MELSEC PLC systems and frequency inverters and to additional products from other
suppliers.
Thus the network is expandable via the digital inputs/outputs of the FX modules to a
maximum of 256 I/Os.
The buffer memory of the FX2N-32CCL is read and written by FROM/TO instructions.
The connection is to the extension bus on the right side of the controller.
FX2N-32CCL
Note: For more informations about CC-Link please refer to the "Automation Book".
LRUN • LERR • RD • SD
Module type
Link points per station
Max. number of I/O points
Number of connectable modules
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
SPECIAL FUNCTION MODULES
4
Remote station
I/O points 32
register 8
—
—
max. 130 mA (from base unit)
50 mA
8
0.3
43x90x87
Order information
Art. no. 102961
왎 Network Module for AS-Interface
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
AS-Interface Module FX2N-32ASI-M
The FX2N-32ASI-M serves as master module for the connection of the FX1N, FX3G, FX3U
and FX3UC PLC to the AS-Interface system. Up to 31 slave units with up to 4 inputs and
4 outputs can be controlled.
U ASI
ASI ACTIVE
POWER
ADRESS/ERROR
FX2N -32ASI-M
PRJ MODE
PRG ENABLE
FROM/TO
CONFIG ERR
Module type
Max. number of I/O points
Communication protocol
Communication speed
Method
Communication cable
Total extension distance
Max. number of controllable units
I/O refresh time
Network setup
Display
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
kbps
m
kg
mm
FX2N-32ASI-M
Master module
128 (with FX1N PLC); 256 (with FX3G PLC); 384 (with FX3U/FX3UC PLC)*
AS-Interface standard
167
APM method (Alternating Pulse Modulation)
AS-Interface standard cable
100 (up to 2 repeaters can be used on the system. The total extension distance may
be extended by 100m for each repeater.)
Up to 31 slave modules (up to 4 inputs / 4 outputs per slave)
Max. 5 ms
2 key network setup
7-segment display for status and diagnosis messages
150 mA (from base unit)
70 mA external
8
0.2
55x90x87
Art. no. 103314
*Including I/O points in PLC and network.
40
MITSUBISHI ELECTRIC
NETWORK MODULES ///
왎 Network Module for Ethernet
þ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Ethernet Communications Adapter FX2NC-ENET-ADP
The FX2NC-ENET-ADP communications adapter is an Ethernet interface with 10BASE-T
specifications for the FX1S and FX1N series.
The FX2NC-ENET-ADP enables upload, download, monitor and test sequence of programs
via Ethernet from a personal computer (GX Developer or MX Component and the virtual
COM port driver installed).
FX2NC-ENET-ADP
POWER
LINK
Note: When connecting this adapter module to a FX1S or FX1N PLC the communications adapter
FX1N-CNV-BD is required.
ACT
SD
RD
Order information
왎 Network Module for Ethernet
TCP/IP
1
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT)
RJ45 (to Ethernet), 3 screw terminals (to ground)
10 Mbit/s
CAT5 STP or 3 STP
0
135 mA (from base unit)
—
kg 0.1
mm 19.1x90x78
4
Art. no. 157447
¨ FX1S ¨ FX1N þ FX3G þ FX3U þ FX3UC
Ethernet Communications Module FX3U-ENET
RUN
INIT.
100M
SD
RD
ERR.
COM.ERR.
POWER
FX3U-ENET
10BASE-T/100BASE-TX
C1
C2
C3
C4
C5
C6
C7
C8
The FX3U-ENET communications module provides the FX3G, FX3U or FX3UC with a direct
connection on to an Ethernet network.
With the FX3U-ENET installed an FX3G/FX3U/FX3UC PLC can exchange data quickly and
easily with process visualization systems in addition to supporting full program
UP/DOWN load as well as comprehensive monitoring support. The module also supports
Peer to Peer connection and MC Protocol. It is easily set-up with the FX Configurator-EN
software.
Note: The FX3U-ENET can be used in combination with a FX3G, FX3U- or FX3UC base unit only.
Protocol
Communication mode
No. of simultaneous open connections
Fixed buffer communication
Communication with mail server
Interface
Connector
Max. transfer rate
Max. segment length
Cable
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
MITSUBISHI ELECTRIC
TCP/IP, UDP
Full-duplex / half-duplex
8
1023 word x 8
SMTP, POP3
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT)
RJ45
100 Mbits/s, 10 Mbit/s
m 100
CAT5 STP or 3 STP
—
240 mA (from base unit)
8
kg 0.3
mm 55x90x87
Art. no. 166086
41
SPECIAL FUNCTION MODULES
Protocol
No. of simultaneous open connections
Interface
Connector
Max. transfer rate
Cable
Related I/O points
5 V DC
Power supply
24 V DC
Weight
Dimensions (WxHxD)
/// NETWORK MODULES
왎 Network Module for Profibus/DP
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
Master module FX3U-64DP-M
RUN
The FX3U-64DP-M PROFIBUS/DP master module enables you to integrate a MELSEC FX3U
or FX3UC PLC system as a class 1 master of a PROFIBUS/DP network.
This interface module provides your FX3U/FX3UC base unit with an intelligent Profibus/DP
link for the implementation of decentralised control tasks.
The FX3U Profibus/DP master provides comprehensive data and alarm processing to the
Profibus/DP V1 standard. It is easily set up with the GX Configurator-DP software.
TOKEN
FROM/TO
Note: The FX3U-64DP-M can be used in combination with a FX3U- or FX3UC base unit only.
ERROR
POWER
FX 3U -64DP-M
Module type
Transmission type
Transmission data
Interface
Max. number of master per configuration
Repeaters
Max. number of slaves
Communications speed
Communications distance
Communication cable
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
SPECIAL FUNCTION MODULES
4
Order information
Master
Bus network
32 byte/slave (normal service mode)
244 byte/slave (extended service mode)
PROFIBUS/DP (with 9 pole D-SUB connector)
1
3
64
PROFIBUS standard
m Max. 1,200 (depends on communication speed)
PROFIBUS cable with 9-pin D-SUB connector
—
Max. 155 mA (from base unit)
8
kg 0.2
mm 43x90x87
Art. no. 166085
PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or
PROFICON-PLUS-PG, art. no. 140009
Accessories
왎 Network Module for Profibus/DP
¨ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Slave Module FX0N-32NT-DP
FX 0N -32NT-DP
POWER
DC
BF
DIA
RUN
The FX0N-32NT-DP PROFIBUS/DP slave module enables you to integrate a MELSEC FX1N
in an existing PROFIBUS/DP network.
This interface module provides your FX1N CPU with an intelligent PROFIBUS/DP link for the
implementation of decentralised control tasks.
It links the system to the master PLC in the PROFIBUS/DP network for efficient and
trouble-free data exchange.
Module type
Interface
Communications speed
Profibus specifications
Communications distance
Communication cable
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
Order information
Accessories
42
Slave
PROFIBUS/DP (with 9 pole D-SUB connector)
PROFIBUS standard
PROFIBUS standard
m Max. 1,200 (depends on communication speed)
PROFIBUS cable with 9-pin D-SUB connector
Max. 170 mA (from base unit)
60 mA
8
kg 0.3
mm 43x90x87
Art. no. 62125
PROFIBUS connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or
PROFICON-PLUS-PG, art. no. 140009
MITSUBISHI ELECTRIC
NETWORK MODULES ///
왎 Network Module for Profibus/DP
¨ FX1S ¨ FX1N þ FX3G þ FX3U þ FX3UC
FX3U-32DP PROFIBUS DP Slave Module
The FX3U-32DP PROFIBUS DP slave module is available for FX3 series main units and
allows the attached FX main unit to function as a slave station on a PROFIBUS DP-V1 network. PROFIBUS DP-V1 functionality supports extensive alarm processing and messaging
on top of standard cyclic data exchange.
Note: When attaching the FX3U-32DP to an FX3UC main unit, the FX2NC-CNV-IF interface converter or
the FX3UC-1PS-5V power supply unit is required.
RUN
TOKEN
FROM/TO
DIA
POWER
Order information
Slave station
Bus network
Max. 144 bytes
PROFIBUS DP connector
8
Max. 12 Mbps
Max. 1,200m (depends on communication speed)
PROFIBUS cable with PROFIBUS DP connector
8
Internal 24 V DC/145 mA
0.2
43x90x89
4
SPECIAL FUNCTION MODULES
Module type
Transmission type
Transmission data
Interface
Max. number of slave stations per configuration
Communication speed
Communication distance
Communication cable
Related I/O points
Power supply
Weight
kg
Dimensions (WxHxD)
mm
FX3U-32DP
Art. no. 194214
왎 Remote I/O Station for PROFIBUS/DP
Remote I/O Station FX2N-32DP-IF
RUN
STOP
L
COM
N
24 +
MITSUBISHI
POWER
RUN
The remote I/O station FX2N-32DP-IF forms an extremely compact communication unit
and provides a connection of I/O modules with up to 256 I/O points and/or up to 8 special
function modules as an alternative.
It features an entire electrical isolation of the PROFIBUS/DP connector and of the
sensor/actuator circuits.
The FX2N-32DP-IF includes a 240 V power supply unit and a 24 V service voltage
terminal, e.g. for analog modules. The FX2N-32DP-IF-D is supplied with 24 V DC.
PROFIBUS data such as the baud rate or I/O data can be monitored directly with the programming software or on the hand-held programming units FX-10P/FX-20P/ FX-30P. This
facilitates an easy error diagnosis directly on the remote I/O station.
BF
DIA
64
32
16
8
4
2
1
FX2N-32DP-IF
ON
FX2N-32DP-IF-D
100–240 V AC
24 V DC
(+10 %/-15 %) 50/60 Hz
(+20 %/-30 %)
30 VA
14 W
5 V DC/max. 220 mA (from base unit), 5 V DC/max. 220 mA (from base unit)
24 V DC/500 mA
9-pin D-SUB for PROFIBUS/DP,
8-pin Mini-DIN for PC or programming unit FX-10P/FX-20P/FX-30P
Power supply
OFF
Power consumption
Internal current consumption
Interface (connectors)
Communication
speed
distance
1200 m
1000 m
400 m
200 m
100 m
Communication distance
Communication cable
Max. number of controllable I/O points
Related I/O points
Weight
Dimensions (WxHxD)
Order information
MITSUBISHI ELECTRIC
kbps
kbps
kbps
kbps
kbps
m
9.6/19.2/45.45/93.75
187.5
500
1500
3000/6000/12000
Max. 1200 (depends on communication speed)
PROFIBUS cable with 9-pin D-SUB connector
256
0
kg 0.4
mm 75x98x87
Art. no. 145401
142763
43
/// NETWORK MODULES
왎 Network Module for DeviceNet
¨ FX1S ¨ FX1N þ FX3G þ FX3U þ FX3UC
DeviceNet Slave Module FX2N-64DNET
POWER
The DeviceNet slave module FX2N-64DNET can be used to connect FX3G and FX3U programmable controllers to a DeviceNet network.
The FX2N-64DNET can communicate to the master by the master/slave communication
(using the master/slave I/O connection), and to other nodes supporting the UCMM connection by client/server communication (using the UCMM connection).
The communication between the programmable controller and the internal buffer
memory of the FX2N-64DNET is handled by FROM/ TO instructions.
FX 2N -64DNET
/TO
MS
NS
Module type
Node type
Station numbers
Supported communication speeds
Communication
data
(open
connection)
4
Master/
slave
UCMM
client/server
SPECIAL FUNCTION MODULES
Communication data
(I/O connection)
kbps
no. of connections
transfer time-out
no. of connections
data length
type
data length
Module ID code
Status displays
Related I/O points
Power supply
5 V DC
24 V DC
Weight
Dimensions (WxHxD)
Order information
mA
kg
mm
Slave (group 2)
G2 Server
0–63 points
125/250/500
1 connection (group 2)
2,000 ms (ACK time-out)
63/63 (group 1, 3)
Max. 64 bytes per connection
Polling, cyclic, change of state
Max. 64 bytes (fragmentation is possible)
K 7090
Power, module status, network status
8
120 mA
50 mA
0.2
43x90x87
Art. no. 131708
왎 Network Module for CANopen
¨ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
CANopen Master-Modul FX2N-32CAN
RUN
FROM/TO
Tx/Rx
ERROR
POWER
FX2N -32CAN
The FX2N-32CAN communications module makes it possible to connect an FX1N, FX3G or
FX3U/FX3UC PLC to an existing CANopen network.
In addition to real-time capabilities and high-speed data transfer at rates of up to 1Mbit/s the
CANopen module also shines with high transfer reliability and simple network configuration.
Up to 120 data words can be sent and received as process data objects (30 PDOs). The number
of words that can be transmitted in each direction can be set between 1 and 120.
Communication with the module’s memory buffer is performed with simple FROM/TO
instructions.
Module type
Power supply
CAN standard
CANopen standard by CiA
CANopen master
5 V DC (via base unit)
ISO 11898/1993
DS-301 version 3.0
NMT, Guarding, and Guarding request based on DS-302 V2.0.
network variables based on DS-405 V1.0
Additional CANopen features
Max. nbr. of modules that can be connected
to the network
Station numbers
Supported baud rate
kBaud
Status displays
Related I/O points
5 V DC
Power supply
24 V DC
Weight
kg
Dimensions (WxHxD)
mm
Order information
44
30 without repeater; 127 with repeater
1–127
10, 20, 50, 125, 250, 500, 800, 1000
RUN, Error, Power, Network status
8
290 mA
—
0.2
43x90x88.7
Art. no. 141179
MITSUBISHI ELECTRIC
COMMUNICATIONS MODULES ///
왎 Modbus & Serial Communication Special Adapters
þ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
Active data modules (RS485)
The addition of active data interface modules permit active communication between the
PLC and surrounding devices. With RS485 communication can be configured as either
1:N multidrop, parallel link or peer to peer operation.
FX3U-485ADP-MB also supports Modbus RTU and Modbus ASCII.
FX3U -485ADP-MB
POWER
RD
SD
330
OPEN
RDA
110
RS485
kbps 0.3–19.2
m 500
Max. 150 mA (from base unit)
—
0
kg 0.1
mm 19.1x90x78
SDA
RDB
FX2NC-485ADP
Interface
Communication speed*
Max. communication distance
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
FX3U-485ADP-MB �
RS485; Modbus RS485
0.3–19.2
500
20 mA (from base unit)
—
0
0.08
17.6x90(106)x74
Art. no. 149111
206191
SG
SDB
Order information
왎 Interface Modules
þ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
Active Data Interface Modules FX2NC-232ADP, FX3U-232ADP
The additional active data interface modules permit active communication between the
PLC and surrounding RS232C peripherals. All device information can be sent or received
via these interfaces.
The module is suitable for the connection of printers, bar code readers, PCs and other PLC
systems. The communication is handled by the PLC program using the RS instruction.
The connection is to the communications bus on the left side of the controller.
The internal serial RS422 interface is also fully available.
FX2NC-232ADP
POWER
RD
SD
FX3U -232ADP
POWER
RD
SD
FX2NC-232ADP
FX3U-232ADP
Note: The FX2NC-232ADP requires a FX2N-CNV-BD interface adapter when connecting to a FX1S or FX1N
base unit.
The FX3U-232ADP can be used in combination with a FX3G, FX3U or FX3UC base unit only. When connecting
the interface modules to a FX3U base unit, an interface or communications adapter FX3U-쏔쏔쏔-B is required.
A direct connection without adapter is possible if these modules are connected to a FX3UC base unit.
Interface
Communication speed*
Communication distance
Communication cable
Communication mode
kbps
m
Protocols
Format
Power supply
Related I/O points
Weight
Dimensions (WxHxD)
Order information
5 V DC
24 V DC
kg
mm
FX3U-232ADP
RS232C with 9 pin D-SUB compact plug (photocoupler isolation)
0.3–19.2
0.3–115.2
Max. 15
Max. 15
Shielded cable
Shielded cable
Half duplex /Full Duplex
Half duplex /Full Duplex
Computer link (dedicated protocol: format1, format4), no protocol,
optional programming port
7 or 8 bits, parity: none/even/odd,
7 or 8 bits, parity: none/even/odd,
stop bits: 1 or 2
stop bits: 1 or 2
100 mA (from base unit)
30 mA (from base unit)
—
—
0
0
0.1
0.08
19.1x90x83
17.6x90(106)x81.5
Art. no. 149110
165276
* Speed depends on communication method (No protocol, Dedicated protocol, Protocol for programming tool)
MITSUBISHI ELECTRIC
45
4
SPECIAL FUNCTION MODULES
FX3U-485ADP
�
Application for FX1S/FX1N base unit � Application for FX3G/FX3U/FX3UC base units
* Speed depends on communication method (Parallel link, N:N Network, No protocol, Dedicated protocol etc.)
Note: When connecting these adapter modules to a FX3U, a communications adapter FX3U-첸첸첸-BD is required. When connecting the
FX2NC adapters to a FX1S or FX1N PLC the communications adapter FX1N-CNV-BD is required. When connecting an FX3U adapter to a FX3G
PLC the communications adapter FX3G-CNV-ADP is required.
/// COMMUNICATIONS MODULES/EXTENSION ADAPTERS
왎 Interface Modules
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
Interface Module FX2N-232IF
The interface module FX2N-232IF provides an RS232C interface for serial data communications with the MELSEC FX3U and FX3UC.
Communication with PCs, printers, modems, barcode readers etc. is handled by the PLC
program.
The send and receive data are stored in the FX2N-232IF’s own buffer memory.
Changes at the user program are not possible via this interface module.
Interface
Communication speed
Communication distance
Communication cable
Communication mode
Protocols
Send and receive buffer
Format
5 V DC
Power supply
24 V DC
Related I/O points
Weight
Dimensions (WxHxD)
SPECIAL FUNCTION MODULES
4
Order information
왎 Digital Extension Adapter Boards
RS232C with 9 pole D-SUB connector (photocoupler isolation)
kbps 0.3–19.2
m Max. 15
Shielded cable
Full duplex
Non protocol mode/start stop synchronisation
512 byte each
7 or 8 bits, parity none/even/odd, stop bits: 1 or 2
40 mA (from base unit)
80 mA
8
kg 0.3
mm 55x90x87
Art. no. 66640
þ FX1S þ FX1N ¨ FX3G ¨ FX3U ¨ FX3UC
Extension Adapters FX1N-4EX-BD, FX1N-2EYT-BD
•
The extension adapters for the FX1N series are available with 4 inputs or 2 outputs.
They are installed directly in the controller of the FX1S or FX1N series and therefore do not
require any additional installation space.
These adapters are especially advantageous when only few additional I/Os are required
and there is not enough room for an adjacent module to be installed.
BY0+ BY0- BY1+ BY1-
FX1N-2EYT-BD
FX1N-2EYT-BD
Connector side
Applicable for
Integrated inputs/outputs
Power supply
Integrated inputs
voltage
Input level
current
Integrated outputs
Output type
Max. switching voltage
Weight
Dimensions (WxHxD)
Order information
46
Base units FX1S/FX1N
4
From base unit
4
24 V DC (+20 %/-15 %)
5 mA (24 V DC)
—
—
V —
kg 0.02
mm 43x38.5x22
Art. no. 139418
FX1N-2EYT-BD
Base units FX1S/FX1N
2
From base unit
—
—
—
2
Transistor
5–30 V DC
0.02
43x38.5x22
139420
MITSUBISHI ELECTRIC
EXTENSION ADAPTERS ///
왎 Analog Adapter Boards
þ FX1S þ FX1N þ FX3G ¨ FX3U ¨ FX3UC
Analog Adapter Boards FX1N-2AD-BD, FX1N-1DA-BD, FX3G-1DA-BD and
FX3G-2AD-BD
•
FX1N-2AD-BD
Connector side
Applicable for
Power supply
Analog channels
•
•
FX1N-1DA-BD
inputs
outputs
V+
Analog input range
I+
VI+
Input resistance
External load
FX1N-1DA-BD
voltage input
current input
voltage output
current output
kW
W
kW
W
analog ® digital
digital ® analog
ms
Resolution
Overall accuracy
Conversion speed
Connector side
Related I/O points
Weight
Dimensions (WxHxD)
kg
mm
Order information
Art. no. 139421
Applicable for
Power supply
Analog channels
inputs
outputs
Analog input range
Input resistance
External load
FX3G-2AD-BD
voltage input
current input
voltage output
current output
kW
W
kW
W
analog ® digital
digital ® analog
ms
Resolution
Overall accuracy
Conversion speed
Related I/O points
Weight
Dimensions (WxHxD)
Order information
Base units FX1S/FX1N
From base unit
2
—
0 –+10 V DC/4–+20 mA
300
250
—
—
2.5 mV (12 bits)/8 µA (11 bits)
±1 %
1 program cycle
—
0
0.02
43x38.5x22
kg
mm
Base units FX3G
From base unit
2
—
0 –+10 V DC/4–+20 mA
198.7
250
—
—
2.5 mV (12 bits)/8 µA (11 bits)
±1 %
180 µs (1 program cycle)
—
0
0.02
35x51.2x29.2
Art. no. 221265
Base units FX1S/FX1N
From base unit
—
1
0 –+10 V DC/4–+20 mA
—
—
2 –1,000
< 500
2.5 mV (12 bits)/8 µA (11 bits)
±1 %
—
1 program cycle
0
0.02
43x38.5x22
4
SPECIAL FUNCTION MODULES
BY0+ BY0- BY1+ BY1-
The analog input adapter boards FX1N-2AD-BD and FX3G-2AD-BD provide the user with
2 analog inputs.
The boards convert analog process signals into digital values which are further processed
by the MELSEC controller.
The analog adapters FX1N-1DA-BD and FX3G-1DA-BD provide the user with 1 analog output. The modules convert digital values from the FX1S/FX1N/FX3G controller to the analog
signals required by the process.
FX1N-2AD
139422
Base units FX3G
From base unit
—
1
0 –+10 V DC/4–+20 mA
—
—
2 –1,000
< 500
2.5 mV (12 bits)/8 µA (11 bits)
±1 %
—
60 µs (1 program cycle)
0
0.02
35x51.2x29.2
221266
FX3G-1DA-BD
MITSUBISHI ELECTRIC
47
/// ADAPTER BOARDS
왎 Setpoint Adapter Boards
þ FX1S þ FX1N þ FX3G ¨ FX3U ¨ FX3UC
Analog Setpoint Adapters FX1N-8AV-BD and FX3G-8AV-BD
FX1N-8AV-BD
FX1N-8AV-BD
Applicable for
Power supply
Adjusting range
Related I/O points
Potentiometer evaluation
Weight
Dimensions (WxHxD)
FX3G-8AV-BD
4
Order information
FX3G-8AV-BD
Base units FX1S/FX1N
Base units FX3G
From base unit
From base unit
8 bit
8 bit
0
0
Via application instruction from the PLC CPU (FNC 85/86)
kg 0.02
0.02
mm 43x38.5x22
35x51.2x12
Art. no. 130744
왎 Communications Adapter Boards
221267
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U ¨ FX3UC
Adapter Board FX3U-USB-BD
R
D
SD
This adapter board allows direct USB 2.0 connection to the front of the FX3U PLC for
program maintenance.
FX3U-USB-BD
SPECIAL FUNCTION MODULES
The FX첸첸-8AV-BD analog setpoint adapters enable the user to set 8 analog setpoint
values. The analog values of the potentiometers are read into the controller and used as
default setpoint values for timers, counters and data registers by the user’s PLC programs.
Setpoint value polling and the definition of the potentiometer scales are performed in
the PLC program using the dedicated instructions VRRD/VRSC (FNC85/86).
The FX첸첸-8AV-BD analog setpoint adapters are installed in the expansion slot of the
FX1S/FX1N/ FX3G CPU. No additional power supply is required for operation.
Applicable for
Power supply
Weight
Dimensions (WxHxD)
Order information
왎 Expansion Adapters
Base units FX3U
5 V DC (from base unit)
kg 0.02
mm 19.6x46.1x53.5
Art. no. 165284
þ FX1S þ FX1N þ FX3G þ FX3U ¨ FX3UC
Expansion Adapters FX1N-CNV-BD, FX3G-CNV-ADP, FX3U-CNV-BD
The below listed expansion adapters enable the connection of the adapter modules
FX첸첸-첸첸첸ADP on the left hand side of the FX1N, FX3G and FX3U base units.
FX3G -CNV
-ADP
FX3G-CNV-ADP
Applicable for
Weight
Dimensions (WxH)
Order information
Base units FX1S/FX1N
kg 0.01
mm 43x38x(D)14
Art. no. 130745
Base units FX3G
0.1
90x14.6x(D)86
Base units FX3U
0.01
19.6x46.1x(D)53.5
221268
165285
FX3G-CNV-ADP
48
MITSUBISHI ELECTRIC
INTERFACE ADAPTERS ///
왎 Interface Adapters
FX3U-232-BD
FX3G-232-BD
þ FX1S þ FX1N þ FX3G þ FX3U ¨ FX3UC
Interface Adapters FX1N-232-BD, FX3G-232-BD, FX3U-232-BD
The FX첸첸-232-BD interface adapters provide an RS232C interface for serial data communications with the MELSEC FX1S/FX1N/FX3G/FX3U.
Applicable for
Interface
FX3G-232-BD
Base units FX1S/FX1N
Base units FX3G
RS232C with 9 pole D-SUB connector
FX3U-232-BD
Base units FX3U
Power supply
5 V DC/20 mA (from base unit)
—
0.02
35x51.2x17.2
5 V DC/20 mA
(from base unit)
—
0.02
19.3x46.1x62.7
221254
165281
Related I/O points
Weight
Dimensions (WxHxD)
Order information
—
kg 0.02
mm 43x38.5x22
Art. no. 130743
Interface Adapters FX1N-422-BD, FX3G-422-BD, FX3U-422-BD
FX3U-422-BD
The FX첸첸-422-BD interface adapters provide a second RS422 interface for connection of
an additional device to the controller (programming unit or operator terminal).
Applicable for
Interface
Power supply
FX3G-422-BD
Related I/O points
Weight
Dimensions (WxHxD)
Order information
FX3G-422-BD
FX3U-422-BD
Base units FX1S/FX1N
Base units FX3G
Base units FX3U
RS422 with 8 pole mini DIN connector
5 V DC/60 mA
5 V DC/20 mA (from base unit)
(from base unit)
—
—
—
kg 0.01
0.02
0.02
mm 43x38.5x20
35x51.2x14.9
19.6x46.1x53.5
Art. no. 130741
221252
165282
Interface Adapters FX1N-485-BD, FX3G-485-BD, FX3U-485-BD
FX3U-485-BD
The interface adapters FX첸첸-485-BD provide the controller with an additional RS485
interface. The adapter, which is simply inserted into the base unit’s expansion slot,
enables the configuration of RS485 1:n multidrop, parallel link or peer-to-peer networks
with FX1S/FX1N/FX3G/FX3U systems.
Applicable for
Interface
Power supply
FX3G-485-BD
Related I/O points
Weight
Dimensions (WxHxD)
Order information
MITSUBISHI ELECTRIC
Base units FX1S/FX1N
RS485/RS422
5 V DC/60 mA
(from base unit)
—
kg 0.02
mm 43x38.5x22
Art. no. 130742
FX3G-485-BD
Base units FX3G
FX3U-485-BD
Base units FX3U
5 V DC/20 mA
(from base unit)
—
0.02
35x51.2x29.2
5 V DC/40 mA
(from base unit)
—
0.02
19.6x46.1x69
221253
165283
49
SPECIAL FUNCTION MODULES
4
/// EXPANSION ADAPTER/MEMORY CASSETTES
왎 Expansion Adapter
¨ FX1S ¨ FX1N ¨ FX3G ¨ FX3U þ FX3UC
FX2NC-CNV-IF
The FX2NC-CNV-IF expansion adapter connects FX3UC main units with the standard
FX0N/FX2N/FX3U right side expansion bus.
FX2NC-CNV-IF
Bus connection
Weight
Dimensions (WxHxD)
Order information
FX3UC bus to FX0N/FX2N/FX3U bus
kg 0.3
mm 90x 4.6x74
Art. no. 104508
FX2NC-CNV-IF
왎 Memory Media
þ FX1S þ FX1N þ FX3G ¨ FX3U ¨ FX3UC
Memory cassettes for FX1S, FX1N and FX3G
5
8L
PLC
WR
ON
ACCESSORIES
PROTECT
SW
RD
8L
OFF
PLC
FX1N-EEPROM-8L
All FX1S, FX1N and FX3G base units are equipped with a slot for the optional, robust FX
memory cassettes. By connection of these memory cassettes, the internal memory of the
controller is switched off and only the program specified in the respective memory cassette
is run.
The memory cassettes can upload/download programs to and from the FX PLC internal
memory with the help of 2 buttons.
The memory cassette FX3G-EEPROM-32L can also be placed on top of the standard BD
expansion boards.
Applicable for
Memory type
Size
Protect switch
Data transfer buttons
Order information
FX3G-EEPROM-32L
Base units FX3G
EEPROM
32000 steps
Provided
Provided
Base units FX1S/FX1N
EEPROM
2000/8000 steps
Provided
Provided
Art. no. 130746
221269
FX3G-EEPROM-32L
왎 Memory Media
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
Memory Cassettes for FX3U/FX3UC
The memory cassette can be installed at the main unit, and when installed, the memory
cassette’s internal program is used in place of the internal RAM memory.
The FX3U-FLROM-64L features additional data transfer buttons.
FX3U-FLROM-64L
Applicable for
Number of steps
Memory type
Protect switch
Data transfer buttons
Dimensions (WxHxD)
Order information
50
Base units FX3U/FX3UC
16,000
Flash memory
Provided
Not provided
mm 37x20x6.1
Art. no. 165278
Base units FX3U/FX3UC
64,000
Flash memory
Provided
Not provided
37x20x6.1
Base units FX3U/FX3UC
64,000
Flash memory
Provided
Provided
37x20x6.1
165279
165280
MITSUBISHI ELECTRIC
EXTERNAL TERMINAL BLOCKS ///
왎 Terminal Blocks
These terminal blocks are adapter modules that simplify the wiring of the inputs and
outputs of the FX3UC main units with ribbon cable connectors. This practical, time-saving wiring system also improves the performance of the outputs. Special terminal blocks
are also available for the FX3U/FX3UC positioning modules with ribbon cable connectors.
Input blocks, output blocks and combined I/O blocks are available, with a choice of
different terminal types.
The TB-쏔EX쏔 input blocks are fitted with rows of bridged connectors for 24V/0V terminals, which make wiring quick and easy.
The TB-8EY-S and TB-8EY-C output blocks consist of 8 standard terminals and a system
adapter. The standard terminals can be populated with relay or transistor elements,
which makes it possible to configure the system for much higher output currents.
Preconfigured system cabling is available for all the terminal blocks (see next page).
20
8 10 12 14 16 18
6
4
2
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
TB-20C
.6 .7
.0 .1 .2 .3 .4 .5
TB-쏔EX쏔
Type
Integrated inputs
Design
Connection type
Application
Dimensions (WxHxD)
Order information
TB-8EX-C
TB-16EX-S
Input block
Input block
Input block
8
8
16
Initiator module with potential terminals
Screw terminals
Spring terminals
Screw terminals
FX2NC series base and extension modules with connectors
mm 75x45x54
75x45x63
116x45x54
Art. no. 149144
Accessories
149145
149021
TB-16EX-C
Input block
16
Spring terminals
116x45x63
149022
5
Connection Cable (see following page)
.0
.1
.3
.2
-
24V+
System adapter
.7
.6
.5
.4
/OUT
PLC-V8/FLK14
Art. 22 95 55 4
Type
Channels
Design
Connection type
Socket
A2-
A2-
24
V
A2-
24
V
A2-
24
V
A2-
24
V
A2-
24
V
A2-
A2-
24
V
24
V
24
V
Application
Dimensions (WxHxD)
Order information
TB-8EY-C
Output block
Output block
8
8
Socket for relay or transistor elements
Screw terminals
Spring terminals
FX2NC series base and extension modules
with connectors
mm 49.6x100x94
49.6x100x94
Art. no. 149044
Pluggable function elements (see below),
Connection cable (see following page)
Accessories
Base
terminal
Catch
149045
TB-20-S
Input/output block
8/16
20 pin terminal module
Screw terminals
ACCESSORIES
Power supply
terminal
TB-20C
Input/output block
8/16
Spring terminals
FX2N series positioning module
75x45x52
75x45x52
149148
149023
Connection cable (see following page)
TB-쏔EY쏔
Terminal opertion
aperture
The transistor and relay elements are plugged directly into the standard terminals in the
TB-8EY-S or TB-8EY-C modules. All the elements feature a status LED, protection against
reverse polarity connection and a freewheeling diode.
Neighbouring terminals with identical voltages can be connected with plug-in strip
bridge connectors, which can be cut to length as required.
LED status
display
Inserted
relay or
transistor
element
Contact for
plug-in strip
bridge
Notch lever for
securing and
ejecting
Output type
Number of elements
Rated input voltage
Switching voltage (min./max.)
Limit permanent current
Max. breaking capacity
Ambient temperature
Order information
Accessories
MITSUBISHI ELECTRIC
Relay with 1 switch-over contact
8
24 V DC
12 V AC/DC; 250 V AC/DC
6A
140 W (24 V DC), 1500 VA (250 V AC)
-20–+60 °C
Art. no. 149034 (set with 8 elements)
Transistor (with optocoupler)
8
24 V DC
3 V DC; 33 V DC
3 A (at 20 °C), 2 A (at 60 °C)
—
-20–+60 °C
149035 (set with 8 elements)
Insulated infinite pin bridge for potential isolation, TB-PIB-RD, color red, art.-no.: 149146;
Insulated infinite pin bridge for potential isolation, TB-PIB-BL, color blue art.-no.: 149147;
Isolation plate TB-SP for lateral base terminal connection, art.-no.: 149158
51
/// EXTERNAL TERMINAL BLOCKS
왎 Terminal Connection Cable
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
These preconfigured cables enable quick, error-free wiring of the terminal blocks of the
positioning modules for the FX3U and FX3UC series fitted with ribbon cable connectors.
The cables are available in a choice of lengths between 1 and 5 m. Other lengths are also
possible by special order.
TB-EX-CAB-5M
Application
Length
Order information
For TB-20-쏔 (1:1 cable)
m 1
Art. no. 149038
3
5
149039
149040
TB-EY-CAB-5M
Application
Length
Order information
For 2 x terminal blocks TB-8EY-S or TB-8EY-C (Y cable)
m 1
3
Art. no. 149041
왎 Connection terminals
5
5
149042
149043
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
ACCESSORIES
The base unit FX2NC-16MR-T-DS and the extension units FX2NC -16EX-T-DS and
FX2NC-16EYR-T-DS are fitted with screw terminals as standard equipment.
These plug-in terminals can easily be replaced with spring terminals if required.
Two replacement terminal units are required for each module with 16 I/Os.
Number of terminal points
Connection type
Application
Dimensions (WxHxD)
Order information
52
TB-CON-5-C
5
Spring terminals
Adapter modules
mm 12.5x20x21
Art. no. 221539
10
Spring terminals
Adapter modules and FX2NC-16EX-T-DS /
FX2NC-16EYR-T-DS extension modules
12.5x20x21
149036
MITSUBISHI ELECTRIC
POWER SUPPLIES/BATTERIES ///
왎 24 V Power Supply Unit
þ ALPHA þ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
The ALPHA-POWER units are a convenient power supply for 24 V units and other external
devices. They come with mounting systemfor wall or DIN rail mounting and their dimensions are matched to those of the ALPHA family.
Up to 5 power supply units can be installed together for redundant mode operation or
connected in parallel for more power. The units have an integrated thermal overload
protection circuit and a POWER LED. The output voltage is adjustable.
Application
General specifications
Nominal input voltage
Output voltage
Nominal output current
Max. output current
Ambient temperature
Ambient humidity
Weight
Dimensions (WxHxD)
ALPHA POWER
Input AC
24V 1.75 A
Order information
ALPHA POWER 24-1.75
Power supply for 24 V DC Alpha base units
Conforms to FX family and ALPHA base units
100–240 V (45–65 Hz)
24 V DC (+/-1 %)
0.75 A (at T=55 °C)
1.75 A (at T=55 °C)
1.4 A
3.75 A
-25–+55 °C (operation), -40–+85 °C (storage)
Max. 95 % (no condensation)
kg 0.1
0.2
mm 36x90x61
54x90x61
Art. no. 209029
왎 5 V Power Supply Unit
209030
ALPHA POWER 24-2.5
2.5 A (at T=55 °C)
4.4 A
0.3
72x90x61
209031
¨ FX1S ¨ FX1N ¨ FX3G þ FX3U þ FX3UC
The power supply modules FX3U-1PSU-5V and FX3UC-1PS-5V are used to reinforce the
build-in 5 V DC and 24 V DC power supply of a FX3G/FX3U/FX3UC main unit. They do not
occupy any I/O points and deliver up to 1 A more current for the 5 V system bus (for special function modules).
Up to two FX3U-1PSU-5V or FX3UC-1PS-5V modules can be used. Both modules have an
integrated overload protection available.
Note: The FX3U-1PSU-5V can't be used with a 24 V base unit!
When connecting an input extension module (incl. FX2N-8ER-ES/UL, FX2N-8ER) to the FX3U-1PSU-5V,
supply the power for it from the 24 V DC service power supply of the connected main unit or powered
extension unit on the upstream side.
FX3U -1PSU-5V
FX3U-1PSU-5V
FX3UC-1PS-5V
POWER
Application
General specifications
Nominal input voltage
Output voltage
Max. output current
Ambient temperature
Ambient humidity
Weight
Dimensions (WxHxD)
FX3UC-1PS-5V
Order information
5 V DC
24 V DC
kg
mm
FX3UC-1PS-5V
Power supply for the FX3G/FX3U system bus Power supply for the FX3UC system bus
Conforms to FX family base units
100–240 V (50/60 Hz)
24 V DC (+20 %/-15 %)
5 V DC/24 V DC
5 V DC
1 A at 40 °C; 0.8 A at 55 °C
1A
0.3 A at 40 °C; 0.2 A at 55 °C
—
-25–+55 °C (operation), -40–+85 °C (storage)
Max. 95 % (no condensation)
0.3
0.15
55x90x87
24x90x74
Art. no. 169507
왎 Backup Batteries
210086
¨ FX1S ¨ FX1N þ FX3G þ FX3U þ FX3UC
Batteries
The battery buffers the internal RAM of the MELSEC PLC in the event of a voltage failure.
The battery FX2NC-32BL is suitable for the positioning modules FX2N-20GM.
The battery FX3U-32BL can be used for all base units of the MELSEC FX3G/FX3U/FX3UC series.
Applicable for
FX3U-32BL
MITSUBISHI ELECTRIC
Order information
FX2NC-32BL
FX2N-20GM module
Art. no. 128725
FX3U-32BL
Base unit FX3U
165286
53
5
ACCESSORIES
Output DC
24V 1.75 A
/// CABLES
왎 Cables
þ FX1S þ FX1N þ FX3G þ FX3U þ FX3UC
FX Series connection cables
The cable listed in the following tables are used for FX Series PLC programming, positioning applications, block connections and interface conversion.
Connection cable for RS232C peripherals
FX2N-1RM
to resolver
Application
Length
m 5.0
PC to FX-232AWC-H
PC to GOT
3.0
3.0
76163
124972
FX-232AWC-H
to FX PLC
FX-232AWC-H
to FX PLC
0.3
1.5
25949
—
FX-20P-E to FX PLC
FX-20P-CAB to FX첸 PLC
1.5
0.3
30815
31870
FX-20P-CAB0
Order information
Art. no. 76160
Connection cable for RS-422 peripherals
FX-232AWC-H
to FX첸 PLC
Application
Length
Order information
m 1.5
Art. no. 76094
Connection cable for programming unit
5
ACCESSORIES
Application
FX-16E-500CAB
FX-20P-G/FX-30P to FX첸 PLC
Length
Order information
m 1.5
Art. no. 55917
Connection cable for extension bus
Application
Length
FX0N-65EC
Order information
PLC bus cable for two-stage-configuration with extension units FX첸첸-첸첸ES
m 0.65
Art. no. 45348
Interface converter
Application
Dimensions
Order information
USB to RS422 converter
m 0.063+3.0
Art. no. 165288
RS422 to RS232C converter
0.25x0.8x0.6
159642
왎 Programming Cables
The USB to RS-422 converter FX-USB-AW is
used for the connection between the PLC
and a serial interface of a personal computer. The converter is devided into 2 parts
and thus universally applicable for all
FX-series PLCs.
Connection on PC side
FX-USB-AW
54
Order information
USB
Art. no. 165288
The SC-09 programming cable is used for
the connection between the PLC and a
serial interface of a personal computer. The
cable is devided into 2 parts and thus universally applicable for all Mitsubishi PLCs.
SC-09
9-pin D-SUB
43393
MITSUBISHI ELECTRIC
DISPLAYS ///
왎 Display Modules
Display Module FX1N-5DM and FX3G-5DM
MITSUBISHI
ESC
-
The display modules FX1N-5DM and FX3G-5DM are inserted directly with space-saving
into the controller and enable monitoring and editing of the data stored in the PLC.
The display module e.g. can be used instead of digital switches and external 7-segment
displays in very confined areas.
+
OK
Applicable for
Display
Power supply
Current consumption
Weight
Dimensions (WxHxD)
FX3G-5DM
Order information
Base units FX1S/FX1N
LCD (with backlight)
5 V DC ±5 % (from base unit)
mA 110
kg 0.02
mm 40x32x17
Art. no. 129197
FX3G-5DM
Base units FX3G series
LCD (with backlight)
5 V DC ± 5 % (from base unit)
n/a
0.02
49x34x12
221270
Control and Display Panel FX-10DM-E
The control and display panel FX-10-DM-E provides a key-oriented user-interface and
enables you to monitor and edit process data in the PLC.
The display is arranged in 2 rows of 16 characters each. Functions can be invoked and
values can be edited using the panel keys.
FNC
ENT
Applicable for
Display
Resolution
Power supply
Current consumption
Weight
Dimensions (WxHxD)
Order information
ACCESSORIES
CLR
5
All base units FX1S/FX1N/FX2N/FX3U
LCD (with backlight)
2x16 signs (80x16 pixles)
5 V DC ±5 % (from base unit)
mA 220
kg 0.02
mm 96x62x32
Art. no. 132600
Control and Display Panel FX3U-7DM, Holder FX3U-7DM-HLD
The FX3U-7DM display module can be incorporated in the main unit, or can be installed in
the enclosure using the FX3U-7DM-HLD display module holder.
Panel FX3U-7DM with built-in holder
FX3U-7DM-HLD
Applicable for
Display
Resolution
Power supply
Current consumption
Extension cable
Weight
Dimensions (WxHxD)
Order information
Base units FX3U
16 letters x 4 lines
—
5 V DC (from base unit)
mA 20
—
kg 0.02
mm 48x35x11.5
Art. no. 165268
Base units FX3U
—
—
—
—
Included
0.01
66.3x41.8x13
165287
For further control and operator terminals please refer to the technical catalogue HMI.
MITSUBISHI ELECTRIC
55
/// DIMENSIONS ALPHA
Dimensions of the ALPHA series
AL2-14M쏔-쏔, AL2-24M쏔-쏔
6,0
4,0
4,0
6,0
(A) (B)
DC INPUT
+
-
(A) (B)
1
2
3
DC INPUT
4
5
6
7
8
9
10
11 12 13 14 15
POWER
24V DC
MITSUBISHI
ESC
+
+
90,0
90,0
MITSUBISHI
ESC
-
-
OK
OK
AL2-10MR-D
OUT1
OUT2
OUT3
RELAY
OUTPUT
OUT
OUT4
4,0
4,0
AL2-24MR-D
5
6
7
8
9
6,0
6,0
71,2
52,0
124,6
AL2-2PT-ADP, AL2-2TC-ADP
AL2-ASI-BD
AL2-4EY쏔, AL2-2DA
24,5
53,1
24,5
53,1
35,5
+
EI1
+
EI2
-
+
ASI+
-
-
POWER
24V DC
ASI+
ASI-
ASI-
V1+
V1-
33,5
V2+
V2-
CH1
CH2
OUTPUT
0~10V
MITSUBISHI
MITSUBISHI
6
90
90
90
POWER
DIMENSIONS
CH1
CH2
200°C -50°C Line 200°C -50°C Line
4EX
+
EI3
+
AL2-2PT-ADP
PT100 -50~200°C
EI4
CH2
CH1
L1-
I1-
L2+
L2-
I2-
4
L1+
All dimensions in mm
56
MITSUBISHI ELECTRIC
DIMENSIONS FX1S/FX1N/FX3G BASE UNITS ///
Dimensions of Base Units FX1S
X
X-8
Z
FX1S-10MR-DS
S/S
100-240
VAC
L
X1
N
X0
X3
X5
X2
X7
X4
POWER
RUN
ERROR
FX1S-14MR
OUT
0 1 2 3
4 5
24V
COM0
Y1
COM1
Z
49
FX1S-10MR-ES/UL
60
90
75
FX1S-10MT-DSS
60
90
49
FX1S-14MR-DS
60
90
49
FX1S-14MR-ES/UL
60
90
75
FX1S-14MT-DSS
60
90
49
FX1S-20MR-DS
75
90
49
FX1S-20MR-ES/UL
75
90
75
FX1S-20MT-DSS
75
90
49
FX1S-30MR-DS
100
90
49
FX1S-30MR-ES/UL
100
90
75
FX1S-30MT-DSS
100
90
49
IN
Y-8
Y
MITSUBISHI
Y0
Y
90
X6
0 1 2 3
4 5 6 7
0V
X
60
Y2
COM2
Y4
Y3
14MR
-ES/UL
Y5
2 x ø4,5
All dimensions in mm
Dimensions of Base Units FX1N
X
X–8
L
N
X1
X0
X3
X2
X5
X4
X7
X11
X6
X10
X
X13
X12
X15
X14
X17
X16
X21
X20
X23
X22
X25
X24
X26
POWER
RUN
ERROR
82
90
IN
FX1N-40M
OUT
0 1 2 3 4 5 6
11 12 13 14 15 16 17
0V
24V
Y0
COM0
Y1
COM1
Y2
COM2
Y4
Y3
COM3
Y6
Y5
Y10
Y7
COM4
Y12
Y11
Y14
Y13
COM5
7 10
Y16
Y15
90
FX1N-14MT왏왏왏
90
6
X27
0 1 2 3 4 5 6 7 10
11 12 13 14 15 16 17 20 21
22 23 24 25 26 27
MITSUBISHI
FX1N-14MR왏왏왏
Y17
40M
FX1N-24MR왏왏왏
90
FX1N-24MT왏왏왏
90
FX1N-40MR왏왏왏
130
FX1N-40MT왏왏왏
130
FX1N-60MR왏왏왏
175
FX1N-60MT왏왏왏
175
DIMENSIONS
S/S
100-240
VAC
75
All dimensions in mm
2 x ø4,5
Dimensions of Base Units MELSEC FX3G
87
X
X-8
X
90
35
FX3G-14
90
FX3G-24
90
FX3G-40
130
FX3G-60
175
All dimensions in mm
ø4,5
MITSUBISHI ELECTRIC
57
/// DIMENSIONS FX3U BASE UNITS AND ADAPTERS
Dimensions of Base Units FX3U
X
86
22
Base Units
X1
S/S
L
0V
N
X0
24V
X2
X1
X4
X3
X7
80
90
RUN
BATT
ERROR
03 12
OUT
FX3U-16M
Y2
Y1
Y1
Y2
Y3
Y3
Y5
Y4
Y4
103
FX3U-32M왏왏왏
150
123
FX3U-48M왏왏왏
182
155
FX3U-64M왏왏왏
220
193
FX3U-80M왏왏왏
285
258
FX3U-128M왏왏왏
350
323
03 12
47 56
POWER
Y0
X1
130
X6
X5
IN
Y0
X
FX3U-16M왏왏왏
Y5
47 56
Y6
Y6
Y7
Y7
All dimensions in mm
R
Ø 4.5
Dimensions of Base Units FX3UC
X
Base Units
X
34
34
59.7
85.4
FX3UC-16MT/DSS
FX3UC-32MT/DSS
FX3UC-64MT/DSS
FX3UC-96MT/DSS
6
DIMENSIONS
All dimensions in mm
Dimensions of Adapter Modules FX3U and Extension Adapters
15.5
17.6
Extension Adapters
Ø3.2
46.1
74
FX3U-4AD-ADP
V3+ COM2 I2+ V2+ COM1 I1+ V1+
53.5
19.6
Ø3.2
X
—
—
15,5
—
9,2
All dimensions in mm
46.1
COM4 I4+ V4+ COM3 I3+
106
90
24-
24+
POWER
FX3U-CNV
FX3U-USB
FX3U-485
FX3U-422
FX3U-232
53.5
58
X
19.6
MITSUBISHI ELECTRIC
DIMENSIONS FX0N/FX2N EXTENSION UNITS ///
Dimensions of Compact Extension Units FX0N
87
X
X -10
X
FX0N-40ER-DS
150
FX0N-40ER-ES/UL
150
FX0N-40ET-DSS
150
MITSUBISHI
90
80
35
All dimensions in mm
MELSEC FX0N-24MR-ES
ø4,5
Dimensions of Compact Extension Units and Modular Extension Blocks MELSEC FX2N
87
X
Compact Extension Units
ø4,5
X
Ø4.5
IN 0
FX2N-32E왏왏왏
1
2
3
4
5
6
7
FX2N-48E왏왏왏
182
FX2N-48ER-UA1/UL
220
6
35
90
80
POWER
150
FX2N -16EX
DIMENSIONS
Modular Extension Blocks
IN 0
1
2
3
4
5
6
7
X
4
FX2N-8E왏왏왏
43
FX2N-16E왏왏왏
40
All dimensions in mm
Dimensions of Modular Extension Blocks FX2NC
X
74
Y
Extension Blocks
FX2NC-32EX
-DS
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
90
Power
X0
1
2
3
X4
5
6
7
X0
1
2
3
X4
5
6
7
FX2NC-16EX-DS
FX2NC-16EYT-DSS
FX2NC-16EX-T-DS
FX2NC-16EYR-T-DSS
FX2NC-32EX-DS
FX2NC-32EYT-DSS
X
14.6
14.6
20.2
24.2
26.2
26.2
Y
13
13
15
15
13
13
All dimensions in mm
MITSUBISHI ELECTRIC
59
/// DIMENSIONS SPECIAL FUNCTION MODULES
Dimensions of Special Function Modules MELSEC FX2N
Special Function Modules FX0N/FX2N
87
X
FX0N-3A
FX2N-2DA
FX2N-2AD
FX2N-4DA
FX2N-4AD
FX2N-4AD-TC
FX2N-4AD-PT
FX2N-1HC
FX2N-1PG-E
FX2N-10PG
FX2N-2LC
FX2N-5A
FX2N-232-IF
FX2N-32ASI-M
FX2N-32CCL
FX2N-32CAN
FX2N-64DNET
ø4,5
35
90
80
POWER
FX2N -4AD
24 V
A/D
4
X
43
43
43
55
55
55
55
55
43
43
55
55
55
55
43
43
43
All dimensions in mm
FX2N-8AD
FX2N-32DP-IF
75
90
75
75
RUN
STOP
V1+
24+
24-
I1+
V2+
V3+
I3+
COM1
COM3
I2+
COM2
V4+
I4+
COM4
L
24 +
POWER
106
98
90
105
98
90
COM
N
MITSUBISHI
FX2N-8AD
POWER
RUN
BF
DIA
RUN
FX2N-32DP-IF
V6+
64
32
16
8
4
2
1
V5+
I8+
COM8
I6+
COM6
V8+
COM5
V7+
I7+
COM7
I5+
ON
OFF
Dimensions of Special Function Modules MELSEC FX3U/FX3UC
87
X
Special Function Modules FX3U/FX3UC
ø4,5
POWER
35
90
80
DIMENSIONS
MITSUBISHI
35
6
FX3U -4AD
24 V
A/D
4
FX3U-2HC
FX3U-3A-ADP
FX3U-4DA
FX3U-4AD
FX3U-4LC
FX3U-CF-ADP
FX3U-ENET
FX3U-20SSC-H
FX3U-64CCL
FX3U-64DPM
FX3U-1PSU-5V
FX3UC-4AD
FX3UC-1PS-5V
X
55
17.6
55
55
90
45
55
55
55
43
55
20.2
24.2
All dimensions in mm
60
MITSUBISHI ELECTRIC
DIMENSIONS SPECIAL FUNCTION MODULES ///
Dimensions of Adapters FX1N and FX3G
FX3G Extension Adapters
FX3G-485-BD
FX1N-4EX-BD
43
S/S
FX3G-1DA-BD
FX3G-232-BD
FX3G-2AD-BD
FX3G-422-BD
FX3G-485-BD
FX3G-8AV-BD
51.2
BX1 BX2 BX3
38.5
38,5
BX0
43
35
X1
X
X
14.1
12
14.1
12
14.1
12
X1
15.1
5.2
15.1
2.9
15.1
–
All dimensions in mm
Dimensions for Terminal Blocks
45
TB-20-S
75
50
TB-20-C
75
DIMENSIONS
45
6
50
45
TB-8EX-S
75
54
45
TB-8EX-C
75
63
45
TB-16EX-S
116
62
45
TB-16EX-C
116
MITSUBISHI ELECTRIC
54
All dimensions in mm
61
/// DIMENSIONS ACCESSORIES
Dimensions for Accessories
FX-485PC-IF
FX1N-EEPROM-8L
MITSUBISHI
33
9
8L
WR
80
5 V DC
RS-232C
POWER
RD
SD
PLC
ON
PROTECT
SW
30
FX-485PC-IF
OFF
SDA
SDB
RDA
RDB
LINK SG
RD
8L
100
30
FX3U-FLROM-16/64/64L
51.2
20
FX3G-EEPROM-32L
37
All dimensions in mm
Dimensions for Display Panels
FX1N-5DM
FX3G-5DM
FX3U-7DM
17
11
11.5
40
48
ESC
-
+
35
32
51.2
34.4
8.5
OK
49.4
9.6
12
FX-10DM-E
96
32
MITSUBISHI
DISPLAY MODULE
53
62
DIMENSIONS
6.1
9.6
35
6
PLC
MODEL
FX-10DM-E
SERIAL
030002
V1.00
MITSUBISHI ELECTRIC CORPORATION
CLR
ENT
FNC
4,5
86
All dimensions in mm
62
MITSUBISHI ELECTRIC
PROGRAMMING ///
MELSOFT – Programming and Documentation Software for Standard Personal Computers
With the MELSOFT software family Mitsubishi Electric offers efficient software packages
helping to reduce programming and setup times to a high degree. The MELSOFT software
family provides instant access, direct communications, compatibility, and open exchange
of variables.
The MELSOFT family comprises:
앬 Programming packages AL-PCS/WIN and GX Developer
앬 Various development software for operator terminals (please refer to the
GOT Technical Catalogue )
앬 Software for a dynamic data exchange like MX Change
AL-PCS/WIN is recommended as a cost-effective beginners package for the ALPHA series.
This package offers a quick and easy introduction to programming.
GX Developer is the right decision for a universal programming package.
In addition, GX Developer is fully compatible with all MELSEC PLCs, including A and
Q series controllers.
For detailed information please order our separate MELSOFT brochure.
For structured programming the IEC1131.3 (EN 61131-3) conform programming software
GX IEC Developer is recommended.
왎 ALPHA Programming Software
AL-PCS/WIN Programming Software
All controllers of the ALPHA series can be programmed with the MS Windows software
AL-PCS/WIN. Programming the ALPHA with this software is very easy and is done by placing the different program elements on a graphical programming environment. The connections (wiring) between the inputs, function blocks, and outputs are drawn graphically
by mouse click to build the logic. By this, programs with up to 200 function blocks can be
created, where each single function in a program can be used as many times as desired.
A complete documentation of the program can be created directly from AL-PCS/WIN.
Order information
7
Alpha series
7 languages (English/German/French/Italian/Spanish/Swedish/Russian)
Windows 95/98/ME/NT/2000/XP/Vista
Art. no. 152603
왎 PLC Training Software
FX-TRN-BEG-E Training Software
The FX-TRN-BEG-E training software package is designed to help beginners get started
with the programming of PLC systems. It combines a simulated PLC environment with
expert tutorials. A real-time module simulates the operation of the PLC program. Simulation speed is adjustable and you can also access system elements and display program
status while the process is running.
Series
Whole FX family
Language
English, Russian
Applicable for
Windows 95/98/ME/NT/2000/XP/Vista
Order information
MITSUBISHI ELECTRIC
Art. no. 149714
63
SOFTWARE & PROGRAMMING
Series
Language
Applicable for
/// PROGRAMMING
PLC Programming Software
왎 GX Developer
GX Developer is the standard programming software for all MELSEC PLC series
and combines all functions of MELSEC
MEDOC with the user guidance of
Microsoft Windows.
With this software you can comfortably
create PLC programs alternatively in the
form of Ladder Diagrams or Instruction
Lists. Both forms of representation can be
toggled easily during operation.
Besides efficient monitoring and diagnostics functions GX Developer features an
offline simulation of any PLC type.
With GX Developer all MELSEC PLCs from
the FX1S to the Q25PH (Q series) are supported.
GX DEVELOPER FX
V0878-2L0C-M_2&MORE
GX Developer V0800-1LOC-G
Series
FX1S, FX1N, FX3G, FX3U, FX3UC
FX1S, FX1N, FX3G, FX3U, FX3UC
All MELSEC PLCs
All MELSEC PLCs
Language
German/English
German/English
German
English
Disk type
CD ROM
CD ROM
CD ROM
CD ROM
Art. no. 225141
225155
152816
150420
Order information
Accessory
Programming cable SC-09, art. no.: 43393
왎 GX IEC Developer
GX IEC Developer provides all functions of
the pre-mentioned programs and in addition meets the programming standard:
IEC 1131.3 (EN 61131). This makes the
software ready for the programming standard of the future and offers beside the FX
version in addition the full version as a
basis for the on-leading programming of
the MELSEC AnS/QnAS series, the
SOFTWARE & PROGRAMMING
7
The GX Developer FX is limited to the programming of the FX series.
This software provides all the Windows-specific advantages and is especially
suited to all MELSEC PLCs.
The software is supplied without an SC-09
programming cable, which can be ordered
separately. This cable is needed for the
connection between the PLC and a serial
interface of a personal computer.
GX Developer can be run under MS Windows® XP and Vista.
MELSEC AnU/QnA series and MELSEC System Q.
GX IEC Developer can be run under Windows 95/98 and Windows NT/2000/XP.
The software is supplied without an SC-09
programming cable, which can be ordered
separately. This cable is needed for the
connection between the PLC and a serial
interface of a personal computer.
GX IEC Developer V0703-1LOC-E
Series
FX1S, FX1N, FX3G, FX3U, FX3UC
FX1S, FX1N, FX3G, FX3U, FX3UC
All MELSEC PLCs
All MELSEC PLCs
Language
German
English
German
English
Disk type
CD ROM
CD ROM
CD ROM
CD ROM
221430
221413
221419
Order information
Accessory
64
Art. no. 221425
Programming cable SC-09, art. no.: 43393
MITSUBISHI ELECTRIC
PROGRAMMING ///
Configurations Software
왎 GX Configurator DP
The GX Configurator DP is a user friendly configurations software for the open network
PROFIBUS/DP.
The software package is a 32 bit application and runs under all Windows versions.
Configuration of all PROFIBUS/DP modules for the MELSEC Ans/QnAS and A/Q series and
also the FX family is possible.
Due to the supported extended user parameters of a GSD file, easy parameter setting of
PROFIBUS/DP slave devices is possible even for third-party devices.
The new GX Configurator DP enables the download of all configuration data via an overriding network.
All PROFIBUS modules are configured via the backside bus.
Supported PROFIBUS/DP master modules
for the Mitsubishi MELSEC series
A1SJ71PB92D, AJ71PB92D, QJ71PB92D
Language
English/German
Disk type
CD ROM
Order information
Ac cessory
Art. no. 145312
Programming cable SC-09, art. no.: 43393
왎 FX Configurator FP
Supported modules
for the Mitsubishi MELSEC series
FX3U-20SSC-H
Language
English
Disk type
CD ROM
Order information
Accessory
MITSUBISHI ELECTRIC
Art. no. 189283
Programming cable SC-09, art. no.: 43393
65
7
SOFTWARE & PROGRAMMING
FX Configurator-FP is beneficial for setting up table operation information, servo amplifier parameters and positioning parameters for the FX3U-SSC-H positioning module. Positioning operations and their associated parameters (speeds, addresses, torque limits etc.)
can be monitored and tested with the integrated monitor and test functions.
Control patterns from simple to complicated combinations of positioning commands can
easily be configured with new methods.
The software runs under all Windows versions.
/// PROGRAMMING
왎 Hand-Held Programming Unit
ER
LP
OTH
/HE
EP
L/M
ST
RET
EF
/M
The FX-30P is a small, industrial programming and maintenance tool for the FX Series.
This unit can perform program uploads/downloads and store up to 15 programs in its
internal memory. Keywords can be registered, deleted or canceled in applicable PLCs.
Program monitoring and data device adjustment functionality is also available. To stay
up to date the latest firmware can be downloaded on a PC then installed via the USB port.
PLC programs on the PC can also be transferred via USB, eliminating the need for peripheral devices.
Note: FX-30P firmware and program downloads from a PC via the embedded USB port available in firmware versions 1.10 and later.
Applicable for
Base units FX1S, FX1N, FX3G, FX2N, FX3U, FX3UC
Ambient temperature
0–40 °C
Ambient relative humidity
(non-condensing)
5–95 %
Power supply
5V DC ±5%/155 mA (from main unit)
Display
LCD (with backlight)
Character display
21x8
Keyboard
35
Program capacity
Memory
HPP held data
Cable
Weight
Dimensions(WxHxD)
Order information
Built-in RAM: 64K steps for program monitoring and modification RAM retention (for
about five years, ambient temperature 25 C(77 F)) by battery.
Built-in flash memory ROM: Up to 15 programs can be stored in the built-in flash memory
ROM. Allowable number of writes: 100,000 times
Display language setting (Japanese, English or Chinese), contrast, buzzer sound volume,
brightness adjustment, screen saver and HPP protect key (saved in the built-in flash
memory)
FX-20P-CAB0
kg 0.3
mm 87x170x30
Art. no. 221271
SOFTWARE & PROGRAMMING
7
66
MITSUBISHI ELECTRIC
CERTIFICATIONS ///
CE
EMC
ALPHA 2 Base Units
쎲
AL2-10MR-A
쎲
AL2-10MR-D
쎲
AL2-14MR-A
쎲
AL2-14MR-D
쎲
AL2-24MR-A
쎲
AL2-24MR-D
ALPHA Extension Modules
쎲
AL2-4EX-A2
쎲
AL2-4EX
쎲
AL2-4EYR
쎲
AL2-4EYT
쎲
AL2-2DA
쎲
AL2-2PT-ADP
쎲
AL2-2TC-ADP
쎲
AL2-ASI-BD
FX1S Base Units
쎲
FX1S-10MR-DS
쎲
FX1S-10MR-ES/UL
쎲
FX1S-10MT-DSS
쎲
FX1S-14MR-DS
쎲
FX1S-14MR-ES/UL
쎲
FX1S-14MT-DSS
쎲
FX1S-20MR-DS
쎲
FX1S-20MR-ES/UL
쎲
FX1S-20MT-DSS
쎲
FX1S-30MR-DS
쎲
FX1S-30MR-ES/UL
쎲
FX1S-30MT-DSS
FX1N Base Units
쎲
FX1N-14MR-DS
쎲
FX1N-14MR-ES/UL
쎲
FX1N-14MT-DSS
쎲
FX1N-24MR-DS
쎲
FX1N-24MR-ES/UL
쎲
FX1N-24MT-DSS
쎲
FX1N-40MR-DS
쎲
FX1N-40MR-ES/UL
쎲
FX1N-40MT-DSS
쎲
FX1N-60MR-DS
쎲
FX1N-60MR-ES/UL
쎲
FX1N-60MT-DSS
FX3G Base Units
쎲
FX3G-14MR/ES
쎲
FX3G-14MT/ESS
쎲
FX3G-14MR/DS
쎲
FX3G-14MT/DSS
쎲
FX3G-24MR/ES
쎲
FX3G-24MT/ESS
쎲
FX3G-24MR/DS
쎲
FX3G-24MT/DSS
쎲
FX3G-40MR/ES
쎲
FX3G-40MT/ESS
쎲
FX3G-40MR/DS
쎲
FX3G-40MT/DSS
쎲
FX3G-60MR/ES
쎲
FX3G-60MT/ESS
쎲
FX3G-60MR/DS
쎲
FX3G-60MT/DSS
LVD
uL
cUL
Ship approvals
ABS
DNV
LR
GL
CE
BV
RINA
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
—
—
—
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
쎲
—
쎲
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쑗
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
쎲
—
쎲
—
쎲
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
EMC
LVD
uL
cUL
FX3U Base Units
쎲
쎲
쎲
FX3U-16첸
쎲
쎲
쎲
FX3U-32첸
쎲
쎲
쎲
FX3U-48첸
쎲
쎲
쎲
FX3U-64첸
쎲
쎲
쎲
FX3U-80첸
쎲
쎲
쎲
FX3U-128첸
FX3UC Base Units
쎲
쎲
쎲
FX3UC-16MT/DSS
쎲
쎲
쎲
FX3UC-32MT/DSS
쎲
쎲
쎲
FX3UC-64MT/DSS
쎲
쎲
쎲
FX3UC-96MT/DSS
FX0N/FX2N Extension Units
쎲
쎲
쎲
FX0N-40ER-ES/UL
쎲
쎲
FX0N-40ER-DS
—
쎲
쑗
FX0N-40ET-DSS
—
쎲
쎲
쎲
FX2N-32ER-ES/UL
쎲
쎲
쎲
FX2N-32ET-ESS/UL
쎲
쎲
쎲
FX2N-48ER-DS
쎲
쎲
쎲
FX2N-48ER-ES/UL
쎲
쑗
쎲
FX2N-48ET-DSS
쎲
쎲
쎲
FX2N-48ET-ESS/UL
FX2N Extension Blocks
쎲
쎲
쎲
FX2N-8ER-ES/UL
쎲
쑗
쎲
FX2N-8EX-ES/UL
쎲
쎲
쎲
FX2N-8EYR-ES/UL
쎲
쑗
쎲
FX2N-8EYT-ESS/UL
쎲
쑗
쎲
FX2N-16EX-ES/UL
쎲
쎲
쎲
FX2N-16EYR-ES/UL
쑗
쎲
FX2N-16EYT-ESS/UL 쎲
FX1N/FX2N Special Function Modules
쎲
FX0N-3A
—
—
쎲
쑗
쎲
FX0N-32NT-DP
쎲
쎲
쎲
FX2N-1HC
쎲
쎲
쎲
FX2N-1PG-E
쎲
쑗
쎲
FX2N-2AD
쎲
쑗
쎲
FX2N-2DA
쎲
쑗
쎲
FX2N-2LC
쎲
쑗
쎲
FX2N-4AD
쎲
쑗
쎲
FX2N-4AD-TC
쎲
쑗
쎲
FX2N-4AD-PT
쎲
쑗
쎲
FX2N-4DA
쎲
쑗
쎲
FX2N-5A
쎲
쑗
쎲
FX2N-8AD
쎲
쑗
쎲
FX2N-10PG
쎲
쑗
FX2N-16CCL-M
—
쎲
쑗
FX2N-32ASI-M
—
쎲
쑗
FX2N-32CAN
—
쎲
쑗
FX2N-32CCL
—
쎲
쎲
쎲
FX2N-32DP-IF
쎲
쑗
쎲
FX2N-64DNET
쎲
쑗
FX2N-232IF
—
FX2NC Extension Blocks
쎲
쎲
쎲
FX2NC-16EX-T-DS
쎲
쎲
쎲
FX2NC-16EYR-T-DS
쎲
쎲
쎲
FX2NC-16EX-DS
쎲
쎲
쎲
FX2NC-16EYT-DSS
쎲
쎲
쎲
FX2NC-32-EX-DS
쎲
쎲
쎲
FX2NC-32-EYT-DSS
Ship approvals
ABS
DNV
LR
GL
BV
RINA
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
쎲
쎲
—
쎲
—
쎲
—
—
—
쎲
쎲
—
쎲
—
쎲
—
—
—
쎲
쎲
—
쎲
—
쎲
—
—
—
쎲
쎲
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
—
—
쎲
쎲
쎲
—
—
쎲
쎲
쎲
쎲
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
쎲
—
쎲
쎲
쎲
—
—
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
쎲
—
쎲
—
—
쎲
쎲
—
—
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
쎲
—
—
쎲
쎲
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
쎲
—
—
쎲
쎲
—
—
—
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
쎲
—
—
쎲
쎲
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
쎲
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲 = comply, 쑗 = no need to comply
MITSUBISHI ELECTRIC
67
/// CERTIFICATIONS
CE
EMC LVD
FX2NC Special Function Modules
쎲
FX2NC-485ADP
—
쎲
FX2NC-232ADP
—
쎲
쑗
FX2NC-ENET-ADP
쎲
쑗
FX2NC-1HC
FX3U Special Function Modules
쎲
쑗
FX3U-2HC
FX3U-3A-ADP
쎲
쑗
쎲
쑗
FX3U-4AD
쎲
쑗
FX3U-4DA
쎲
쑗
FX3U-4AD-TC-ADP
쎲
쑗
FX3U-4AD-PT-ADP
쑗
FX3U-4AD-PNK-ADP 쎲
쑗
FX3U-4AD-Ptw-ADP 쎲
쎲
쑗
FX3U-4AD-ADP
쎲
쑗
FX3U-4DA-ADP
쎲
쑗
FX3U-4HSX-ADP
쎲
쑗
FX3U-4LC
쎲
쑗
FX3U-CF-ADP
쎲
쑗
FX3U-2HSY-ADP
쎲
쑗
FX3U-20SSC-H
쎲
쑗
FX3U-485ADP-MB
쎲
쑗
FX3U-232ADP-MB
쎲
쑗
FX3U-ENET
쎲
쑗
FX3U-64DP-M
쎲
FX3U-64CCL
—
Adapter Boards
쎲
쑗
FX1N-1DA-BD
쎲
쑗
FX1N-2AD-BD
쎲
쑗
FX1N-2EYT-BD
쎲
쑗
FX1N-4EX-BD
쎲
쑗
FX1N-8AV-BD
쎲
쑗
FX1N-232-BD
쎲
쑗
FX1N-422-BD
쎲
쑗
FX1N-485-BD
쎲
쑗
FX1N-CNV-BD
쎲
쑗
FX2N-8AV-BD
쎲
쑗
FX2N-232-BD
쎲
쑗
FX2N-422-BD
쎲
쑗
FX2N-485-BD
쎲
쑗
FX2N-CNV-BD
쎲
쑗
FX3G-1DA-BD
쎲
쑗
FX3G-2AD-BD
쎲
쑗
FX3G-8AV-BD
쎲
쑗
FX3G-232-BD
쎲
쑗
FX3G-422-BD
쎲
쑗
FX3G-485-BD
쎲
쑗
FX3U-232-BD
쎲
쑗
FX3U-422-BD
쎲
쑗
FX3U-485-BD
쎲
쑗
FX3U-CNV-BD
쎲
쑗
FX3U-USB-BD
68
uL
cUL
Ship approvals
ABS
DNV
LR
GL
CE
BV
RINA
—
—
쎲
쎲
—
—
—
—
쎲
쎲
—
—
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
쎲
쎲
—
—
—
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
쎲
쎲
—
—
—
—
—
—
—
쎲
쎲
—
—
쎲
쎲
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
쎲
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
Terminal Blocks
TB-20S
TB-20C
Accessories
ALPHA POWER 24
FX1N-5DM
FX-10DM-E
FX-20 P-E-SET0
FX-USB-AW
FX-232AWC-H
FX2N-CNV-IF
FX2N-CNV-BC
FX2NC-CNV-IF
FX3U-1PSU-5V
FX3UC-1PS-5V
FX3U-7DM
FX3U-7DM-HLD
Ship approvals
EMC
LVD
uL
cUL
ABS
DNV
LR
GL
BV
RINA
—
—
쑗
쑗
쎲
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
쎲
—
—
쎲
쎲
쎲
쑗
쑗
쑗
쑗
쑗
쑗
쑗
쑗
—
—
쑗
—
쎲
—
—
—
—
—
—
—
—
—
—
—
—
—
쎲
—
—
—
—
쎲
—
—
—
—
쎲
—
—
쎲
—
—
—
—
—
—
쎲
—
쎲
쎲
—
—
쎲
—
—
—
—
—
—
쎲
—
—
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
쎲
—
—
—
—
—
—
—
—
—
—
—
—
쎲
—
—
쎲
—
—
—
—
—
—
—
—
—
쎲
—
쎲 = comply, 쑗 = no need to comply
MITSUBISHI ELECTRIC
INDEX ///
A
AL-232CAB . . . . . . . . . . . . . . . . . . . . . . . 12
AL2-10MR-A . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-10MR-D . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-14MR-A . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-14MR-D . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-24MR-A . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-24MR-D . . . . . . . . . . . . . . . . . . . . . . . 9
AL2-2DA . . . . . . . . . . . . . . . . . . . . . . . . . 11
AL2-2PT-ADP. . . . . . . . . . . . . . . . . . . . . . 11
AL2-2TC-ADP . . . . . . . . . . . . . . . . . . . . . 11
AL2-4EX . . . . . . . . . . . . . . . . . . . . . . . . . 11
AL2-4EX-A2 . . . . . . . . . . . . . . . . . . . . . . 11
AL2-4EYR . . . . . . . . . . . . . . . . . . . . . . . . 11
AL2-4EYT . . . . . . . . . . . . . . . . . . . . . . . . 11
AL2-ASI-BD . . . . . . . . . . . . . . . . . . . . . . . 12
AL2-EEPROM-2 . . . . . . . . . . . . . . . . . . . . 12
AL2-GSM-CAB . . . . . . . . . . . . . . . . . . . . . 12
ALPHA 2 series
Accessories . . . . . . . . . . . . . . . . . . . . . 12
Base units . . . . . . . . . . . . . . . . . . . . . . . 9
Dimensions . . . . . . . . . . . . . . . . . . . . . 56
Extension modules . . . . . . . . . . . . . . . . 11
Interface Cable. . . . . . . . . . . . . . . . . . . 12
Memory Cassette . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . 10
System description. . . . . . . . . . . . . . . . . 8
ALPHA POWER 24-0.75 . . . . . . . . . . . . . . . 53
ALPHA POWER 24-1.75 . . . . . . . . . . . . . . . 53
ALPHA POWER 24-2.5 . . . . . . . . . . . . . . . . 53
Accessories
Batteries. . . . . . . . . . . . . . . . . . . . . . . 53
Cables . . . . . . . . . . . . . . . . . . . . . . . . 52
Connection terminals . . . . . . . . . . . . . . 52
Display modules. . . . . . . . . . . . . . . . . . 55
Programming Cables . . . . . . . . . . . . . . 54
Terminal blocks . . . . . . . . . . . . . . . . . . 51
Active data modules . . . . . . . . . . . . . . . . . 45
Adapter boards . . . . . . . . . . . . . . . . . . . . 47
Analog modules. . . . . . . . . . . . . . . . . . . . 33
Dimensions . . . . . . . . . . . . . . . . . . . . . 60
C
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Connection Cable . . . . . . . . . . . . . . . . . . . 52
Modules . . . . . . . . . . . . . . . . . . . . . . . 54
Terminal blocks . . . . . . . . . . . . . . . . . . 52
D
Data logger module . . . . . . . . . . . . . . . . . 36
Dimensions . . . . . . . . . . . . . . . . . . . . . . . 56
Display Modules. . . . . . . . . . . . . . . . . . . . 55
E
Extension Adapter Boards . . . . . . . . . . . . . 46
Extensions
ALPHA 2 Series. . . . . . . . . . . . . . . . . . . 11
Dimensions . . . . . . . . . . . . . . . . . . . . . 59
FX series . . . . . . . . . . . . . . . . . . . . . . . 26
External Terminal Blocks . . . . . . . . . . . . . . 51
F
F2-232CAB-1. . . . . . . . . . . . . . . . . . . . . . 54
F2-RS-5CAB. . . . . . . . . . . . . . . . . . . . . . . 54
FX Configurator FP . . . . . . . . . . . . . . . . . . 65
FX-10DM-E . . . . . . . . . . . . . . . . . . . . . . . 55
FX-20P-CAB. . . . . . . . . . . . . . . . . . . . . . . 54
FX-20P-CAB0. . . . . . . . . . . . . . . . . . . . . . 54
FX-20P-CADP. . . . . . . . . . . . . . . . . . . . . . 54
FX-232AWC-H . . . . . . . . . . . . . . . . . . . . . 54
FX-232CAB-1. . . . . . . . . . . . . . . . . . . . . . 54
FX-422CAB . . . . . . . . . . . . . . . . . . . . . . . 54
FX-422CAB-150 . . . . . . . . . . . . . . . . . . . . 54
FX-422CAB0 . . . . . . . . . . . . . . . . . . . . . . 54
FX-USB-AW . . . . . . . . . . . . . . . . . . . . . . . 54
FX0N-32NT-DP. . . . . . . . . . . . . . . . . . . . . 42
FX0N-3A . . . . . . . . . . . . . . . . . . . . . . . . . 34
FX0N-40ER-DS . . . . . . . . . . . . . . . . . . . . . 29
FX0N-40ER-ES/UL . . . . . . . . . . . . . . . . . . 29
FX0N-40ET-DSS . . . . . . . . . . . . . . . . . . . . 29
FX0N-65EC . . . . . . . . . . . . . . . . . . . . . . . 54
FX1N series
Base units . . . . . . . . . . . . . . . . . . . . . . 17
Specifications . . . . . . . . . . . . . . . . . . . 18
System description . . . . . . . . . . . . . . . . 16
FX1N-14MR-DS . . . . . . . . . . . . . . . . . . . . 17
FX1N-14MR-ES/UL . . . . . . . . . . . . . . . . . . 17
MITSUBISHI ELECTRIC
FX1N-14MT-DSS. . . . . . . . . . . . . . . . . . . . 17
FX1N-1DA-BD . . . . . . . . . . . . . . . . . . . . . 47
FX1N-232-BD . . . . . . . . . . . . . . . . . . . . . 49
FX1N-24MR-DS . . . . . . . . . . . . . . . . . . . . 17
FX1N-24MR-ES/UL . . . . . . . . . . . . . . . . . . 17
FX1N-24MT-DSS. . . . . . . . . . . . . . . . . . . . 17
FX1N-2AD-BD . . . . . . . . . . . . . . . . . . . . . 47
FX1N-2EYT-BD . . . . . . . . . . . . . . . . . . . . . 46
FX1N-40MR-DS . . . . . . . . . . . . . . . . . . . . 17
FX1N-40MR-ES/UL . . . . . . . . . . . . . . . . . . 17
FX1N-40MT-DSS. . . . . . . . . . . . . . . . . . . . 17
FX1N-422-BD . . . . . . . . . . . . . . . . . . . . . 49
FX1N-485-BD . . . . . . . . . . . . . . . . . . . . . 49
FX1N-4EX-BD. . . . . . . . . . . . . . . . . . . . . . 46
FX1N-5DM . . . . . . . . . . . . . . . . . . . . . . . 55
FX1N-60MR-DS . . . . . . . . . . . . . . . . . . . . 17
FX1N-60MR-ES/UL . . . . . . . . . . . . . . . . . . 17
FX1N-60MT-DSS. . . . . . . . . . . . . . . . . . . . 17
FX1N-8AV-BD . . . . . . . . . . . . . . . . . . . . . 48
FX1N-CNV-BD . . . . . . . . . . . . . . . . . . . . . 48
FX1N-EEPROM-8L. . . . . . . . . . . . . . . . . . . 50
FX1S series
Base units . . . . . . . . . . . . . . . . . . . . . . 14
Specifications . . . . . . . . . . . . . . . . . . . 15
System description . . . . . . . . . . . . . . . . 13
FX1S-10MR-DS . . . . . . . . . . . . . . . . . . . . 14
FX1S-10MR-ES/UL . . . . . . . . . . . . . . . . . . 14
FX1S-10MT-DSS . . . . . . . . . . . . . . . . . . . . 14
FX1S-14MR-DS . . . . . . . . . . . . . . . . . . . . 14
FX1S-14MR-ES/UL . . . . . . . . . . . . . . . . . . 14
FX1S-14MT-DSS . . . . . . . . . . . . . . . . . . . . 14
FX1S-20MR-DS . . . . . . . . . . . . . . . . . . . . 14
FX1S-20MR-ES/UL . . . . . . . . . . . . . . . . . . 14
FX1S-20MT-DSS . . . . . . . . . . . . . . . . . . . . 14
FX1S-30MR-DS . . . . . . . . . . . . . . . . . . . . 14
FX1S-30MR-ES/UL . . . . . . . . . . . . . . . . . . 14
FX1S-30MT-DSS . . . . . . . . . . . . . . . . . . . . 14
FX2N-10PG . . . . . . . . . . . . . . . . . . . . . . . 38
FX2N-16CCL-M. . . . . . . . . . . . . . . . . . . . . 39
FX2N-16EX-ES/UL . . . . . . . . . . . . . . . . . . 31
FX2N-16EYR-ES/UL. . . . . . . . . . . . . . . . . . 31
FX2N-16EYT-ESS/UL . . . . . . . . . . . . . . . . . 31
FX2N-1HC . . . . . . . . . . . . . . . . . . . . . . . . 37
FX2N-1PG-E . . . . . . . . . . . . . . . . . . . . . . 38
FX2N-232IF . . . . . . . . . . . . . . . . . . . . . . . 46
FX2N-2AD . . . . . . . . . . . . . . . . . . . . . . . . 33
FX2N-2DA . . . . . . . . . . . . . . . . . . . . . . . . 33
FX2N-2LC . . . . . . . . . . . . . . . . . . . . . . . . 34
FX2N-32ASI-M. . . . . . . . . . . . . . . . . . . . . 40
FX2N-32CAN . . . . . . . . . . . . . . . . . . . . . . 44
FX2N-32CCL . . . . . . . . . . . . . . . . . . . . . . 40
FX2N-32DP-IF . . . . . . . . . . . . . . . . . . . . . 43
FX2N-32DP-IF-D. . . . . . . . . . . . . . . . . . . . 43
FX2N-32ER-ES/UL . . . . . . . . . . . . . . . . . . 30
FX2N-32ET-ESS/UL . . . . . . . . . . . . . . . . . . 30
FX2N-48ER-DS . . . . . . . . . . . . . . . . . . . . . 30
FX2N-48ER-ES/UL . . . . . . . . . . . . . . . . . . 30
FX2N-48ET-DSS . . . . . . . . . . . . . . . . . . . . 30
FX2N-48ET-ESS/UL . . . . . . . . . . . . . . . . . . 30
FX2N-4AD . . . . . . . . . . . . . . . . . . . . . . . . 33
FX2N-4AD-PT . . . . . . . . . . . . . . . . . . . . . 34
FX2N-4AD-TC. . . . . . . . . . . . . . . . . . . . . . 34
FX2N-4DA . . . . . . . . . . . . . . . . . . . . . . . . 33
FX2N-5A . . . . . . . . . . . . . . . . . . . . . . . . . 34
FX2N-64DNET . . . . . . . . . . . . . . . . . . . . . 44
FX2N-8AD . . . . . . . . . . . . . . . . . . . . . . . . 33
FX2N-8ER-ES/UL . . . . . . . . . . . . . . . . . . . 31
FX2N-8EX-ES/UL . . . . . . . . . . . . . . . . . . . 31
FX2N-8EYR-ES/UL . . . . . . . . . . . . . . . . . . 31
FX2N-8EYT-ESS/UL . . . . . . . . . . . . . . . . . . 31
FX2NC-16EX-DS . . . . . . . . . . . . . . . . . . . . 32
FX2NC-16EX-T-DS. . . . . . . . . . . . . . . . . . . 32
FX2NC-16EYR-T-DS. . . . . . . . . . . . . . . . . . 32
FX2NC-16EYT-DSS . . . . . . . . . . . . . . . . . . 32
FX2NC-1HC . . . . . . . . . . . . . . . . . . . . . . . 37
FX2NC-232ADP . . . . . . . . . . . . . . . . . . . . 45
FX2NC-32BL . . . . . . . . . . . . . . . . . . . . . . 53
FX2NC-32EX-DS . . . . . . . . . . . . . . . . . . . . 32
FX2NC-32EYT-DSS . . . . . . . . . . . . . . . . . . 32
FX2NC-485ADP . . . . . . . . . . . . . . . . . . . . 45
FX2NC-CNV-IF . . . . . . . . . . . . . . . . . . . . . 50
FX2NC-ENET-ADP . . . . . . . . . . . . . . . . . . . 41
FX3G series
Base units . . . . . . . . . . . . . . . . . . . . . . 20
Specifications . . . . . . . . . . . . . . . . . . . 21
System description . . . . . . . . . . . . . . . 19
FX3G-14MR/DS . . . . . . . . . . . . . . . . . . . . 20
FX3G-14MR/ES . . . . . . . . . . . . . . . . . . . . 20
FX3G-14MT/DSS. . . . . . . . . . . . . . . . . . . . 20
FX3G-14MT/ESS . . . . . . . . . . . . . . . . . . . . 20
FX3G-1DA-BD . . . . . . . . . . . . . . . . . . . . . 47
FX3G-232-BD. . . . . . . . . . . . . . . . . . . . . . 49
FX3G-24MR/DS . . . . . . . . . . . . . . . . . . . . 20
FX3G-24MR/ES . . . . . . . . . . . . . . . . . . . . 20
FX3G-24MT/DSS. . . . . . . . . . . . . . . . . . . . 20
FX3G-24MT/ESS . . . . . . . . . . . . . . . . . . . . 20
FX3G-2AD-BD . . . . . . . . . . . . . . . . . . . . . 47
FX3G-40MR/DS . . . . . . . . . . . . . . . . . . . . 20
FX3G-40MR/ES . . . . . . . . . . . . . . . . . . . . 20
FX3G-40MT/DSS. . . . . . . . . . . . . . . . . . . . 20
FX3G-40MT/ESS . . . . . . . . . . . . . . . . . . . . 20
FX3G-422-BD. . . . . . . . . . . . . . . . . . . . . . 49
FX3G-485-BD. . . . . . . . . . . . . . . . . . . . . . 49
FX3G-5DM . . . . . . . . . . . . . . . . . . . . . . . 55
FX3G-60MR/DS . . . . . . . . . . . . . . . . . . . . 20
FX3G-60MR/ES . . . . . . . . . . . . . . . . . . . . 20
FX3G-60MT/DSS. . . . . . . . . . . . . . . . . . . . 20
FX3G-60MT/ESS . . . . . . . . . . . . . . . . . . . . 20
FX3G-8AV-BD . . . . . . . . . . . . . . . . . . . . . 48
FX3G-CNV-ADP . . . . . . . . . . . . . . . . . . . . 48
FX3G-EEPROM-32L . . . . . . . . . . . . . . . . . . 50
FX3U series
Base units . . . . . . . . . . . . . . . . . . . . . . 23
Specifications . . . . . . . . . . . . . . . . . . . 25
System description . . . . . . . . . . . . . . . . 22
FX3U-128MR/ES . . . . . . . . . . . . . . . . . . . 24
FX3U-128MT/ESS . . . . . . . . . . . . . . . . . . . 24
FX3U-16MR/DS . . . . . . . . . . . . . . . . . . . . 23
FX3U-16MR/ES . . . . . . . . . . . . . . . . . . . . 23
FX3U-16MT/DSS. . . . . . . . . . . . . . . . . . . . 23
FX3U-16MT/ESS . . . . . . . . . . . . . . . . . . . . 23
FX3U-1PSU-5V. . . . . . . . . . . . . . . . . . . . . 53
FX3U-20SSC-H . . . . . . . . . . . . . . . . . . . . 38
FX3U-232-BD . . . . . . . . . . . . . . . . . . . . . 49
FX3U-232ADP . . . . . . . . . . . . . . . . . . . . . 45
FX3U-2HC . . . . . . . . . . . . . . . . . . . . . . . . 37
FX3U-2HSY-ADP. . . . . . . . . . . . . . . . . . . . 37
FX3U-32BL . . . . . . . . . . . . . . . . . . . . . . . 53
FX3U-32DP . . . . . . . . . . . . . . . . . . . . . . . 43
FX3U-32MR/DS . . . . . . . . . . . . . . . . . . . . 23
FX3U-32MR/ES . . . . . . . . . . . . . . . . . . . . 23
FX3U-32MT/DSS. . . . . . . . . . . . . . . . . . . . 23
FX3U-32MT/ESS . . . . . . . . . . . . . . . . . . . . 23
FX3U-3A-ADP . . . . . . . . . . . . . . . . . . . . . 34
FX3U-422-BD . . . . . . . . . . . . . . . . . . . . . 49
FX3U-485-BD . . . . . . . . . . . . . . . . . . . . . 49
FX3U-485ADP-MB . . . . . . . . . . . . . . . . . . 45
FX3U-48MR/DS . . . . . . . . . . . . . . . . . . . . 24
FX3U-48MR/ES . . . . . . . . . . . . . . . . . . . . 24
FX3U-48MT/DSS. . . . . . . . . . . . . . . . . . . . 24
FX3U-48MT/ESS . . . . . . . . . . . . . . . . . . . . 24
FX3U-4AD . . . . . . . . . . . . . . . . . . . . . . . . 33
FX3U-4AD-ADP . . . . . . . . . . . . . . . . . . . . 35
FX3U-4AD-PNK-ADP . . . . . . . . . . . . . . . . . 35
FX3U-4AD-PT-ADP . . . . . . . . . . . . . . . . . . 35
FX3U-4AD-PTW-ADP . . . . . . . . . . . . . . . . 35
FX3U-4AD-TC-ADP . . . . . . . . . . . . . . . . . . 35
FX3U-4DA . . . . . . . . . . . . . . . . . . . . . . . . 33
FX3U-4DA-ADP . . . . . . . . . . . . . . . . . . . . 35
FX3U-4HSX-ADP. . . . . . . . . . . . . . . . . . . . 37
FX3U-4LC . . . . . . . . . . . . . . . . . . . . . . . . 36
FX3U-64CCL . . . . . . . . . . . . . . . . . . . . . . 39
FX3U-64DP-M . . . . . . . . . . . . . . . . . . . . . 42
FX3U-64MR/DS . . . . . . . . . . . . . . . . . . . . 24
FX3U-64MR/ES . . . . . . . . . . . . . . . . . . . . 24
FX3U-64MT/DSS. . . . . . . . . . . . . . . . . . . . 24
FX3U-64MT/ESS . . . . . . . . . . . . . . . . . . . . 24
FX3U-7DM . . . . . . . . . . . . . . . . . . . . . . . 55
FX3U-7DM-HLD . . . . . . . . . . . . . . . . . . . . 55
FX3U-80MR/DS . . . . . . . . . . . . . . . . . . . . 24
FX3U-80MR/ES . . . . . . . . . . . . . . . . . . . . 24
FX3U-80MT/DSS. . . . . . . . . . . . . . . . . . . . 24
FX3U-80MT/ESS . . . . . . . . . . . . . . . . . . . . 24
FX3U-CF-ADP . . . . . . . . . . . . . . . . . . . . . 36
FX3U-CNV-BD . . . . . . . . . . . . . . . . . . . . . 48
FX3U-ENET . . . . . . . . . . . . . . . . . . . . . . . 41
FX3U-FLROM-16 . . . . . . . . . . . . . . . . . . . 50
FX3U-FLROM-64 . . . . . . . . . . . . . . . . . . . 50
FX3U-FLROM-64L. . . . . . . . . . . . . . . . . . . 50
FX3U-USB-BD . . . . . . . . . . . . . . . . . . . . . 48
FX3UC-16MT/DSS. . . . . . . . . . . . . . . . . . . 27
FX3UC-1PS-5V . . . . . . . . . . . . . . . . . . . . . 53
FX3UC-32MT/DSS. . . . . . . . . . . . . . . . . . . 27
FX3UC-4AD . . . . . . . . . . . . . . . . . . . . . . . 33
FX3UC-64MT/DSS. . . . . . . . . . . . . . . . . . . 27
FX3UC-96MT/DSS. . . . . . . . . . . . . . . . . . . 27
FX3UC-Serie
Base Units . . . . . . . . . . . . . . . . . . . . . . 27
Specifications . . . . . . . . . . . . . . . . . . . 28
System description . . . . . . . . . . . . . . . . 26
G
GX Configurator DP. . . . . . . . . . . . . . . . . . 65
GX Developer. . . . . . . . . . . . . . . . . . . . . . 64
GX IEC Developer . . . . . . . . . . . . . . . . . . . 64
H
High speed counter . . . . . . . . . . . . . . . . . 37
I
Interface Adapters . . . . . . . . . . . . . . . . . . 49
Interface modules . . . . . . . . . . . . . . . . . . 45
M
Memory Media . . . . . . . . . . . . . . . . . . . . 12,
50
N
Network modules. . . . . . . . . . . . . . . . . . . 39
P
Positioning modules. . . . . . . . . . . . . . . . . 38
Power supply units . . . . . . . . . . . . . . . . . . 53
24 V . . . . . . . . . . . . . . . . . . . . . . . . . . 53
5 V . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
S
SC-09 . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Sample Calculations . . . . . . . . . . . . . . . . . . 7
Ship approvals . . . . . . . . . . . . . . . . . . . . . 67
Software
AL-PCS/WIN . . . . . . . . . . . . . . . . . . . . 63
FX Configurator FP V0100-1LOC-E. . . . . . 65
FX-TRN-BEG-E . . . . . . . . . . . . . . . . . . . 63
GX Configurator DP V0500-1L0C-E . . . . . 65
GX DEVELOPER FX V0878-1L0C-M . . . . . . 64
GX DEVELOPER FX V0878-2L0C-M_2&MORE 64
GX Developer V0800-1LOC-E . . . . . . . . . 64
GX Developer V0800-1LOC-G . . . . . . . . . 64
Specifications
ALPHA 2 . . . . . . . . . . . . . . . . . . . . . . . . 9
FX1N series . . . . . . . . . . . . . . . . . . . . . 18
FX1S series . . . . . . . . . . . . . . . . . . . . . 15
FX3G . . . . . . . . . . . . . . . . . . . . . . . . . 21
FX3U series . . . . . . . . . . . . . . . . . . . . . 25
FX3UC series . . . . . . . . . . . . . . . . . . . . 28
System description
ALPHA 2 series. . . . . . . . . . . . . . . . . . . . 8
FX1N series . . . . . . . . . . . . . . . . . . . . . 16
FX1S series . . . . . . . . . . . . . . . . . . . . . 13
FX3G Series . . . . . . . . . . . . . . . . . . . . . 19
FX3U series . . . . . . . . . . . . . . . . . . . . . 22
FX3UC series . . . . . . . . . . . . . . . . . . . . 26
MELSEC PLC Systems. . . . . . . . . . . . . . . . 4
T
TB-16EX-C. . . . . . . . . . . . . . . . . . . . . . . . 51
TB-16EX-S. . . . . . . . . . . . . . . . . . . . . . . . 51
TB-20-S . . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-20C . . . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-8EX-C . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-8EX-S. . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-8EY-C. . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-8EY-S. . . . . . . . . . . . . . . . . . . . . . . . . 51
TB-8RELAY-6A . . . . . . . . . . . . . . . . . . . . . 51
TB-8TRANSISTOR-2A. . . . . . . . . . . . . . . . . 51
TB-CON-5-C. . . . . . . . . . . . . . . . . . . . . . . 52
TB-CON10-C . . . . . . . . . . . . . . . . . . . . . . 52
TB-EX-CAB-1M. . . . . . . . . . . . . . . . . . . . . 52
TB-EX-CAB-3M. . . . . . . . . . . . . . . . . . . . . 52
TB-EX-CAB-5M. . . . . . . . . . . . . . . . . . . . . 52
TB-EY-CAB-1M. . . . . . . . . . . . . . . . . . . . . 52
TB-EY-CAB-3M. . . . . . . . . . . . . . . . . . . . . 52
TB-EY-CAB-5M. . . . . . . . . . . . . . . . . . . . . 52
Temperature control module . . . . . . . . . . . 36
69
70
MITSUBISHI ELECTRIC
Automation solutions /// Automation solutions /// Automation solutions
A world of
automation solutions
Robots
Motion control and servos
LV circuit protection
Inverters
Laser machines
CNC
controllers
HMI and GOTs
EDM machines
Micro PLCs
Modular PLCs
Mitsubishi offer a wide range of automation equipment from PLCs and HMIs to CNC and EDM machines.
A name to trust
Since its beginnings in 1870, some
45 companies use the Mitsubishi name,
covering a spectrum of finance, commerce and industry.
The Mitsubishi brand name is recognized around the world as a symbol of
premium quality.
Mitsubishi Electric Corporation is active
in space development, transportation,
semiconductors, energy systems, communications and information processing, audio visual equipment, home electronics,
building
and
energy
management and automation systems,
and has 237 factories and laboratories
worldwide in over 121 countries.
This is why you can rely on a Mitsubishi
automation solution – because we know
first hand about the need for reliable,
efficient, easy-to-use automation and
control in our own factories.
As one of the world’s leading companies
with a global turnover of over 4 trillion
Yen (over $40 billion), employing over
100,000 people, Mitsubishi Electric has
the resource and the commitment to
deliver the ultimate in service and support as well as the best products.
Global Partner. Local Friend.
EUROPEAN BRANCHES
MITSUBISHI ELECTRIC EUROPE B.V.
Gothaer Straße 8
D-40880 Ratingen
Phone: +49 (0)2102 / 486-0
EUROPEAN REPRESENTATIVES
GERMANY
GEVA
AUSTRIA
Wiener Straße 89
AT-2500 Baden
Phone: +43 (0)2252 / 85 55 20
AutoCont C.S. s.r.o. CZECH REPUBLIC
Technologická 374/6
CZ-708 00 Ostrava-Pustkovec
Phone: +420 595 691 150
KAZPROMAUTOM. Ltd. KAZAKHSTAN
Mustafina Str. 7/2
KAZ-470046 Karaganda
Phone: +7 7212 / 50 11 50
Beijer Electronics AS
NORWAY
Postboks 487
NO-3002 Drammen
Phone: +47 (0)32 / 24 30 00
Beijer Electronics AB
SWEDEN
Box 426
SE-20124 Malmö
Phone: +46 (0)40 / 35 86 00
TEXEL ELECTRONICS Ltd.
ISRAEL
2 Ha´umanut, P.O.B. 6272
IL-42160 Netanya
Phone: +972 (0)9 / 863 39 80
MITSUBISHI ELECTRIC EUROPE B.V. CZECH REPUBLIC
Radlická 714/113a
CZ-158 00 Praha 5
Phone: +420 - 251 551 470
TEHNIKON
BELARUS
Oktyabrskaya 16/5, Off. 703-711
BY-220030 Minsk
Phone: +375 (0)17 / 210 46 26
B:ELECTRIC, s.r.o. CZECH REPUBLIC
Mladoboleslavská 812
CZ-197 00 Praha 19 - Kbely
Phone: +420 286 850 848
Beijer Electronics SIA
LATVIA Sirius Trading & Services ROMANIA
Ritausmas iela 23
Aleea Lacul Morii Nr. 3
LV-1058 Riga
RO-060841 Bucuresti, Sector 6
Phone: +371 (0)784 / 2280
Phone: +40 (0)21 / 430 40 06
Omni Ray AG
SWITZERLAND
Im Schörli 5
CH-8600 Dübendorf
Phone: +41 (0)44 / 802 28 80
CEG INTERNATIONAL
LEBANON
Cebaco Center/Block A Autostrade DORA
Lebanon - Beirut
Phone: +961 (0)1 / 240 430
MITSUBISHI ELECTRIC EUROPE B.V.
25, Boulevard des Bouvets
F-92741 Nanterre Cedex
Phone: +33 (0)1 / 55 68 55 68
FRANCE
ESCO D & A
BELGIUM
Culliganlaan 3
BE-1831 Diegem
Phone: +32 (0)2 / 717 64 30
Beijer Electronics A/S
DENMARK
Lykkegårdsvej 17
DK-4000 Roskilde
Phone: +45 (0)46/ 75 76 66
Beijer Electronics UAB LITHUANIA
Savanoriu Pr. 187
LT-02300 Vilnius
Phone: +370 (0)5 / 232 3101
Craft Con. & Engineering d.o.o. SERBIA
Bulevar Svetog Cara Konstantina 80-86
SER-18106 Nis
Phone: +381 (0)18 / 292-24-4/5
GTS
TURKEY
Bayraktar Bulvari Nutuk Sok. No:5
TR-34775 Yukarı İSTANBUL
Phone: +90 (0)216 526 39 90
CBI Ltd.
SOUTH AFRICA
Private Bag 2016
ZA-1600 Isando
Phone: + 27 (0)11 / 977 0770
MITSUBISHI ELECTRIC EUROPE B.V.
Viale Colleoni 7
I-20041 Agrate Brianza (MB)
Phone: +39 039 / 60 53 1
ITALY
Koning & Hartman b.v.
BELGIUM
Woluwelaan 31
BE-1800 Vilvoorde
Phone: +32 (0)2 / 257 02 40
Beijer Electronics Eesti OÜ ESTONIA
Pärnu mnt.160i
EE-11317 Tallinn
Phone: +372 (0)6 / 51 81 40
ALFATRADE Ltd.
MALTA INEA SR d.o.o.
SERBIA
99, Paola Hill
Izletnicka 10
Malta- Paola PLA 1702
SER-113000 Smederevo
Phone: +356 (0)21 / 697 816
Phone: +381 (0)26 / 617 163
CSC Automation Ltd.
UKRAINE
4-B, M. Raskovoyi St.
UA-02660 Kiev
Phone: +380 (0)44 / 494 33 55
MITSUBISHI ELECTRIC EUROPE B.V.
Krakowska 50
PL-32-083 Balice
Phone: +48 (0)12 / 630 47 00
POLAND
INEA BH d.o.o. BOSNIA AND HERZEG.
Aleja Lipa 56
BA-71000 Sarajevo
Phone: +387 (0)33 / 921 164
Beijer Electronics OY
FINLAND
Peltoie 37
FIN-28400 Ulvila
Phone: +358 (0)207 / 463 540
INTEHSIS srl
MOLDOVA
bld. Traian 23/1
MD-2060 Kishinev
Phone: +373 (0)22 / 66 4242
AutoCont Control s.r.o.
SLOVAKIA
Radlinského 47
SK-02601 Dolny Kubin
Phone: +421 (0)43 / 5868210
MITSUBISHI ELECTRIC EUROPE B.V.
SPAIN
Carretera de Rubí 76-80
E-08190 Sant Cugat del Vallés (Barcelona)
Phone: 902 131121 // +34 935653131
AKHNATON
BULGARIA
4 Andrej Ljapchev Blvd. Pb 21
BG-1756 Sofia
Phone: +359 (0)2 / 817 6004
UTECO A.B.E.E.
GREECE HIFLEX AUTOM. B.V. NETHERLANDS
5, Mavrogenous Str.
Wolweverstraat 22
GR-18542 Piraeus
NL-2984 CD Ridderkerk
Phone: +30 211 / 1206 900
Phone: +31 (0)180 – 46 60 04
CS MTrade Slovensko, s.r.o. SLOVAKIA
Vajanskeho 58
SK-92101 Piestany
Phone: +421 (0)33 / 7742 760
MITSUBISHI ELECTRIC EUROPE B.V.
Travellers Lane
UK-Hatfield, Herts. AL10 8XB
Phone: +44 (0)1707 / 27 61 00
INEA CR d.o.o.
CROATIA
Losinjska 4 a
HR-10000 Zagreb
Phone: +385 (0)1 / 36 940 - 01/ -02/ -03
MELTRADE Ltd.
HUNGARY
Fertő utca 14.
HU-1107 Budapest
Phone: +36 (0)1 / 431-9726
INEA d.o.o.
SLOVENIA
Stegne 11
SI-1000 Ljubljana
Phone: +386 (0)1 / 513 8100
UK
Koning & Hartman b.v. NETHERLANDS
Haarlerbergweg 21-23
NL-1101 CH Amsterdam
Phone: +31 (0)20 / 587 76 00
Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Gothaer Straße 8 /// D-40880 Ratingen /// Germany
Tel.: +49(0)2102 4860 /// Fax: +49(0)2102 4861120 /// [email protected] /// www.mitsubishi-automation.com
Specifications subject to change /// Art.-no. 167840-F /// 10.2010
All trademarks and copyrights acknowledged.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF