PW 6107
Installation plan
Washer-extractor
PW 6107 EL
en - GB
10.11
M.-Nr. 09 270 450 / 01
M.-Nr. 09 270 450 / 01
2
Technical Datasheet
Washer-extractor:
Heating:
PW 6107
Electric (EL)
Legend:
en-GB
Solid circle around symbol:
Connection mandatory
Broken circle around symbol:
Connection optional or as required
Optional extras:
UM
Miele plinth
UO 6010 (UO = Open plinth)
Height
Width
Depth
mm
mm
mm
144
780
789
UG 6010 (UG = Box plinth)
Height
Width
Depth
mm
mm
mm
144
800
799
UO 6010-30 (UO = Open plinth)
Height
Width
Depth
mm
mm
mm
300
780
789
UG 6010-30 (UG = Box plinth)
Height
Width
Depth
mm
mm
mm
300
800
799
Recommended height
Minimum height
Min. plinth width
Min. plinth depth
mm
mm
mm
mm
150
100
950
910
V
3N AC 380 - 415
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable (not supplied)
Hz
kW
A
mm²
50 - 60
11
3 × 16
5 × 2.5
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable (not supplied)
V
Hz
kW
A
mm²
3 AC 220 - 240
50 - 60
11
3 × 25
4 ×4
BS
Concrete plinth
WI
Weighing
system
Model version with integrated weighing system
OS
Offshore
Special offshore version
Machine connections:
Electrical
connection
1. Standard voltage (as supplied)
Country variations:
Technisches Datenblatt / Technical datasheet: PW 6107 EL
Datum / Date: 12.10.2011
Seite / Page: 8
1. Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable (not supplied)
V
Hz
kW
A
mm²
3 AC 220 - 240
50 - 60
11
3 × 25
4 × 4.0
Alternative voltage (convertible)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable (not supplied)
V
Hz
kW
A
mm²
3 AC 208
60
9.5
3 × 25
4×4
V
Hz
kW
A
mm²
3 AC 440
60
11
3 × 16
4 × 2.5
mm
M
10 × 35
10
V
mm²
AC 230
5 × 1.5
Non-standard voltages:
OS 440
Standard voltage (as supplied)
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Connection cable (not supplied)
Electrical connection must comply with national legislation, guidelines and ordinances as well as local
regulations. Guidelines issued by power utilities and
insurance companies, occupation safety regulations
and general good practices also apply.
Connection should only be performed by a qualified
person with suitable training.
The machine can be hard-wired or installed with a
plug connection according to IEC 60309-1. A wall
socket or mains isolator must be accessible after
installation.
A plug and socket connection is recommended to
facilitate accessibility for electrical safety tests.
If an earth-leakage circuit breaker (RCD) is required
by local regulations, a Type B device (sensitive to all
types of current) should be installed.
Equi-potential
bonding
Sleeve with external thread
for washer and nut
Fitting such as washers and nuts are only supplied
with the OS machine version.
If necessary, equipotential bonding with good galvanic contact must be provided in accordance with all
appropriate national and local regulations.
Peak-load
cut-off
Connection voltage for control signals
Connection cable, min. cross-section
Connection cable (not supplied)
Miele recommends the use of a flexible supply lead
and an additional cut-off switch. The switch should be
visible and accessible after installation.
Technisches Datenblatt / Technical datasheet: PW 6107 EL
Datum / Date: 12.10.2011
Seite / Page: 9
Cold water
Soft water
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
Max. throughput (if hot or raw water supply is not
available)
kPa
kPa
l/min
l/min
100
1000
26
42
Inch
mm
1" external thread
1500
l/h
Approx. 76
Max. water intake temperature
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
°C
kPa
kPa
l/min
70
100
1000
16
1 inlet hose with ¾" threaded union supplied.
On-site connection thread according to DIN 44 991
Length of inlet hose
Inch
mm
¾" external thread
1500
l/h
Approx. 82
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
kPa
kPa
l/min
100
1000
32
2 inlet hoses with ¾" threaded union including Ypiece (¾" / 1") included (optional).
On-site connection thread according to DIN 44 991
Length of inlet hose
Inch
mm
1" external thread
1500
Average water requirements for standard programme
(60°C Cottons) for cold, hot and raw water connections.
l/h
Approx. 48
Min. water pressure/flow pressure
Max. water pressure/flow pressure
Max. throughput
kPa
kPa
l/min
100
1000
5.5
1 inlet hose with ¾" threaded union included
(optional).
On-site connection thread according to DIN 44 991
Length of inlet hose
Inch
mm
¾" external thread
1500
Max. water temperature
Waste water connection on machine (ext. diameter)
Drain connection on site (int. diameter)
Max. transient throughput
°C
mm
mm
l/min
95
75 [DN 70]
75 [DN 70]
200
2 inlet hoses with ¾" threaded union including Ypiece (¾" / 1") included.
On-site connection thread according to DIN 44 991
Length of inlet hose
Average water requirements for standard programme
(60°C Cottons) for cold, hot and raw water connections.
Additional requirements if hot water supply is not
available.
If connected to grey water supply, subtract cold water
(soft) volume.
Hot water
(soft water)
Average water requirements for standard programme
(60°C Cottons) for cold, hot and raw water connections.
In the absence of a hot water supply, the hot water
hose should be connected to cold water!
Cold water
Raw water
Cold water
Liquid
dispensing
Waste water
Drain valve
Vented drainage required. If ventilation is insufficient,
fit Miele kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.
Technisches Datenblatt / Technical datasheet: PW 6107 EL
Datum / Date: 12.10.2011
Seite / Page: 10
Fasteners
Without plinth
The machine must be firmly anchored to the floor!
Anchor fittings included:
2 × angle brackets (from shipping lock)
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
mm
mm
8 x 80
12 x 60
mm
mm
8 x 80
12 x 60
mm
mm
8 x 80
12 x 60
mm
mm
8 x 80
12 x 60
mm
12
The floor must be solid and able to support the machine. The fittings included are suitable for a solid
concrete floor. Anchor bolts and fittings for other floor
types must be provided on site.
On concrete plinth
The machine must be firmly anchored to the floor!
Anchor fittings included:
2 × angle brackets (from shipping lock)
2 × bolts DIN 571 (Ø × length)
2 × rawl plugs (Ø × length)
The grade of concrete should be suitable for the load.
The plinth should be firmly anchored to the floor to
accommodate dynamic stress!
Miele plinth
The plinth must be firmly anchored to the floor!
Anchor fittings included with plinth:
4 × bolts DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
Both the machine and the plinth must be installed
according to the installation instructions provided.
Machine
version
WI
The machine must be firmly anchored to the floor!
Anchor fittings included:
4 × angled anchor brackets
4 × bolts DIN 571 (Ø × length)
4 × rawl plugs (Ø × length)
The floor must be solid and able to support the machine. The fittings included are suitable for a solid
concrete floor. Anchor bolts and fittings for other floor
types must be provided on site.
Machine
version
OS
The machine must be firmly anchored to the floor!
Fittings not supplied with machine.
Internal anchor thread
Installation must comply with local requirements and
cater for on-site conditions. The machine is supplied
without feet to allow the interior thread to be used
with stay bolts.
Technisches Datenblatt / Technical datasheet: PW 6107 EL
Datum / Date: 12.10.2011
Seite / Page: 11
Machine data
Machine width
Machine depth
Machine height
Casing width
Casing depth
mm
mm
mm
mm
mm
804
925
1250
800
800
Min. access width to installation site
Recommended rear wall gap (measured to front of
machine)
Minimum wall gap (measured to rear of machine lid)
mm
mm
810
1250
mm
400
Net weight
Dynamic floor load, max.
Static floor load, max.
Dynamic load, max.
Drum frequency, max.
Average heat dissipation
(dependent on ambient room temperature and programme selected)
kg
N
N
N
Hz
W
320
3931
3483
448
20
1050
Sound pressure level (re 20 mPA),
workplace-related
(at distance of 1 m and height of 1.6 m)
dB (A)
66
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Dimensions in mm
Technisches Datenblatt / Technical datasheet: PW 6107 EL
Datum / Date: 12.10.2011
Seite / Page: 12