Heat & Glo HST48D woodburning fireplace Owner's Manual
Below you will find brief information for woodburning fireplace HST48D. This document will guide you through important safety and operating information. It will also provide instructions on how to properly use the fireplace.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Owner’s Manual
Operation and Care
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
► Contact your dealer with questions on installation, operation, or service.
NOTICE: DO NOT discard this manual!
Model(s):
HST48D
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
• DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• DO NOT overfire. Overfiring will void your warranty.
• Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable materials.
• Keep clothing, furniture, draperies and other flammable materials away.
WOODBURNING FIREPLACE
Installation and service of this fireplace should be performed by qualified personnel. Hearth & Home
Technologies recommends NFI certified professionals, or technicians supervised by an
NFI certified professional.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 1
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Indicates practices which may cause damage to the fireplace or to property.
1 Welcome
A. Congratulations
B. LIMITED LIFETIME WARRANTY
2 Product Specific and General Information
A. Appliance Certification
B. Vented Gas Log Sets, Gas Inserts, Gas Log Lighters
and Wood-burning Inserts
3 Important Safety and Operating Information
A. Fireplace Safety
1. Clear Space
2. Grate
3. Refractory
4. Firescreen
5. Flue Damper
6. Glass Doors
7. Over-Firing Your Fireplace
8. Chimney Fire
B. General Operating Parts
1. Flue Damper
2. Outside Air (Optional)
3. Glass Doors
C. Fuel
1. Hardwood vs. Softwood
2. Moisture content
3. Seasoning
4. Storing Wood
5. Burning Process
6. Creosote Formation
7. Processed Solid Fuel Firelogs
D. First Fire
E. Lighting Instructions
6
6
10
10
10
11
10
10
8
9
8
8
8
8
8
8
7
7
12
12
12
11
11
12
12
3
4
Table of Contents
►
4 Maintenance and Service
A. Chimney Inspection
B. Creosote (Chimney) Cleaning
C. Grate
D. Glass Cleaning
E. Ash Removal
F. Refractory/Firebrick
5 Troubleshooting
►
A. FAQs
6 Reference Materials
►
A. Service Parts
B. Accessories
C. Contact Information
16
18
19
20
13
13
14
14
14
14
2 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
1
Welcome
A. Congratulations
Read this manual before installing or operating this fireplace.
Please retain this owner’s manual for future references.
Congratulations on selecting a Heat & Glo wood burning fireplace. The Heat & Glo fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.
As the owner of a new fireplace, you'll want to read and carefully follow all of the instructions contained in this
Owner's Manual. Pay special attention to all Cautions and
Warnings.
This Owner's Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.
Your new Heat & Glo wood burning fireplace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fireplace products!
Heat & Glo is a registered trademark of Hearth & Home
Technologies.
Local Dealer Information
DEALER: Fill in your name, address, phone and e-mail information here and fireplace information below.
Dealer Name: ________________________________________________________
Address: ____________________________________________________________
____________________________________________________________
Phone: _____________________________________________________________
E-mail: _____________________________________________________________
Fireplace Information:
Brand: ________________________________________________ Model Name: ___________________________
Serial Number: __________________________________________ Date Installed: __________________________
Listing Label Information/Location
The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.
Serial
Number
Grate
Fireplace
Model
FIREPLACE NO.
WARNING: RISK OF
FIRE DAMAGE. REPLACE
GRATE WITH HEARTH & HOME
TECHNOLOGIES
MODEL NO. MODEL NO. MFG. DATE
FIRECHAMBER INTENDED FOR USE WITH HEARTH & HOME TECHNOLOGIES LISTED FIREPLACE PARTS. SEE INSTALLATION AND
OPERATING INSTRUCTIONS FOR THIS MODEL. ONLY HEARTH & HOME TECHNOLOGIES GLASS DOOR KITS CAN BE INSTALLED ON THIS UNIT.
FIREPLACE ALSO FOR USE
IN MANUFACTURED HOMES
YES NO
CLEARANCE TO
COMBUSTIBLES:
CHIMNEY
2 IN. MIN. FIREBOX
IN.
MIN.
FAN KIT
MODEL NO. &
DO NOT OVERFIRE. USE ONLY: SOLID WOOD FUEL OR
LISTED DECORATIVE GAS APPLIANCE. DO NOT USE A
FIREPLACE INSERT OR OTHER PRODUCTS NOT
SPECIFIED FOR USE WITH THIS PRODUCT. IF DOORS
ARE USED OPERATE FIREPLACE WITH DOORS FULLY
OPEN OR CLOSED ONLY. WHEN BURNING A
DECORATIVE GAS APPLIANCE IN THE FIREPLACE,
ADJUST DAMPER TO THE FULLY OPEN POSITION.
RATED AT
115 VOLTS, 50/60 Hz., AMP.
WARNING! THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED
GAS LOG SET. TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT
INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE.
WARNING! THIS APPLIANCE IS NOT FOR USE AS COOKING EQUIPMENT.
IF INSTALLATION OR OPERATING INSTRUCTIONS ARE MISSING
CONTACT: HEARTH & HOME TECHNOLOGIES,
7571 215th Street West, Lakeville, MN 55044
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 3
Hearth & Home Technologies, on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.
WARRANTY PERIOD:
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.
Warranty Period
Parts Labor
1 Year
2 years
3 years
5 years 1 year
7 years 3 years
10 years
1 year
Limited
Lifetime 3 years
90 Days
4021-645F 02-18-13
Gas
HHT Manufactured Appliances and Venting
Wood Pellet
EPA
Wood
Coal Electric Venting
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
Components Covered
All parts and material except as covered by Conditions,
Exclusions, and Limitations listed
Igniters, electronic components, and glass
Factory-installed blowers
Molded refractory panels
Firepots and burnpots
Castings and baffles
Manifold tubes,
HHT chimney and termination
Burners, logs and refractory
X
X
X
X
X
X
X
X
X
X X X
See conditions, exclusions, and limitations on next page.
Firebox and heat exchanger
All replacement parts beyond warranty period
Page 1 of 2
4 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
WARRANTY CONDITIONS:
• This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of
HHT authorized dealers is available on the HHT branded websites.
• This warranty is only valid while the HHT appliance remains at the site of original installation.
• This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides.
• Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product.
• Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this warranty.
WARRANTY EXCLUSIONS:
This warranty does not cover the following:
• Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty.
• Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.
• Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass.
• Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to this noise are not covered by this warranty.
• Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the appliance.
• Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.
• Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.
• HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.
This warranty is void if:
• The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.
• The appliance is subjected to prolonged periods of dampness or condensation.
• There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.
LIMITATIONS OF LIABILITY:
• The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you.
This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO
THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE.
4021-645F 02-18-13
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
Page 2 of 2
5
2
Product Specific and General Information
A. Appliance Certification
This fireplace system has been tested and listed in accordance with UL 127 and ULC-S610 standards by Underwriters Laboratories Inc. for installation and operation in the United States and Canada.
This fireplace may be installed in sleeping rooms EX-
CEPT in manufactured homes. If installed with a gas log set, provisions for the National Fuel Gas Code must be met.
B. Vented Gas Log Sets, Gas Inserts, Gas
Log Lighters and Wood-burning Inserts
• Optional
• Vented gas log sets, gas inserts, gas log-lighters or wood-burning inserts can be installed in this fireplace.
Follow the instructions provided with the accessory for operation.
This fireplace has been tested and listed for use with the optional components specified in this manual. These optional components may be purchased separately and installed at a later date. Installation of an outside air kit will require significant reconstruction and is best if installed at the time of fireplace installation.
Heat & Glo is a registered trademark of Hearth & Home
Technologies.
• DO NOT install unvented gas logs.
• Damper must be locked open.
• Gas flame may generate fumes.
Warning! Risk of Fire!
For use with solid wood fuel only.
Other fuels may overfire and generate poisonous gases
(i.e. carbon monoxide).
6 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
3
Important Safety and Operating Information
A. Fireplace Safety 1. Clear Space
Most problems are caused by improper installation and operation of the fireplace. To provide reasonable fire safety, the following should be given serious consideration:
Combustible materials must not be stored on the hearth extension. Room furnishings such as drapes, curtains, chairs or other combustibles must be at least 4 ft
(1219 mm) from the front of the fireplace.
• The fire should be supervised whenever the fireplace is in use.
• An annual inspection should be performed on the fireplace system.
• Install at least one smoke detector on each floor of your home to ensure your safety.
• Install a conveniently located Class A fire extinguisher near the fireplace.
• Devise a practiced evacuation plan, consisting of at least two escape routes.
• Devise a plan to deal with a chimney fire:
- Evacuate.
- Notify the fire department.
Combustible materials are materials made of or surfaced with any of the following materials:
- Wood
- Plant fibers
- Compressed paper
- Plastic
- Plywood/OSB - Drywall
- Any material that can ignite and burn, flame proofed or not, plastered or un-plastered.
Non-combustible materials are materials which will not ignite and burn, composed of any combination of the following:
- Steel
- Brick
- Concrete
- Glass
- Iron
- Tile
- Slate
- Plasters
WARNING! Risk of Fire! Hearth & Home Technologies disclaims any responsibility for, and the warranty and agency listing will be voided by the following actions.
WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace.
DO NOT:
• operate damaged fireplace
• modify fireplace
• overfire
• install any unvented gas log set
• install any component not approved by Hearth & Home
Technologies
• install parts or components not Listed or approved
• operate the fireplace without fully assembling all components
DO NOT:
• store flammable materials close to the fireplace
• use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace.
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
48 in. (1219 mm)
Clear Space
Front of Fireplace 24 in. (610 mm)
Clear Space
Sides of Fireplace Opening
63-3/4 in. (1619 mm)
Clear Space
Bottom of Fireplace to
Lower Edge of
Mantel or Trim
Figure 3.1 Clear Space
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 7
2. Grate
This fireplace is designed to be used with the supplied grate or one approved by HHT.
Risk of Fire! Use only the factory-supplied integral grate.
• Keeps logs in place.
• Allows proper air circulation around the fire.
3. Refractory
The refractory is supplied to contain heat and provide an attractive interior.
It will break down over time and will need occasional replacement. Small hairline cracks and discoloration are normal and do not affect its safety.
Risk of Fire! DO NOT burn fireplace without refractory. Use only refractory supplied by Hearth &
Home Technologies.
4. Firescreen
The firescreen is provided to control sparks. Keep it closed when the fireplace in use.
• Screen will not prevent burning materials from falling out.
• Screen pulls or handles may be hot.
5. Flue Damper
The flue damper must be in the fully opened position during operation of the fireplace.
Risk of Fire and Asphyxiation! Open damper prior to operating fireplace. A closed damper overfires the fireplace and spills smoke and flames into the room.
6. Glass Doors
Glass doors are optional.
Risk of Fire! Install ONLY doors approved by Hearth & Home Technologies.
Risk of Fire and Smoke! Fireplace equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace opening.
7. Over-Firing Your Fireplace
Over-firing may ignite creosote or will damage the fireplace and chimney.
To prevent over-firing your fireplace. DO NOT:
• use flammable liquids
• overload with wood
• burn trash or large amounts of scrap lumber
• permit too much air to the fire
Symptoms of over-firing may include one or more of the following:
• chimney connector or fireplace glowing
• roaring, rumbling noises
• loud cracking or banging sounds
• metal warping
• chimney fire
8. Chimney Fire
In the event of a chimney fire
• Have the chimney and adjacent structure inspected by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of an NFPA 211
Level 2 inspection of the chimney.
• Replace components of the chimney and fireplace as specified by the professionals.
• Ensure all joints are properly engaged and the chimney is properly secured.
Risk of Fire! A chimney fire can permanently damage your chimney system. Failure to replace damaged components and make proper repairs can cause a structure fire.
8 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable materials.
• Keep clothing, furniture, draperies and other flammable materials away.
CAUTION! If you expect that children may come into contact with this fireplace, we recommend a barrier such as a decorative screen. See your dealer for suggestions.
B. General Operating Parts
WARNING! DO NOT operate fireplace before reading and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury.
Air Kit Handle Location
(just above stone) open
Damper
Handle close close open
Figure 3.2 General Operating Parts
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 9
1. Flue Damper
Refer to Figure 3.2 for location and operation of control.
Before lighting the fireplace, verify fully open position by looking up from the inside of the fireplace.
2. Outside Air (Optional)
Refer to Figure 3.2 for location and operation of control.
The outside air kit supplies some combustion air for your fireplace. It may help reduce the effects of negative air pressure.
Close the inlet to prevent cold drafts when the fireplace is not being used
Outside air control handle may be warm.
Adjust before lighting fire.
3. Glass Doors
• Glass doors are optional.
• Refer to Figure 3.3 for how to properly use them.
FULLY OPEN
CORRECT
PARTLY OPEN
INCORRECT
FULLY CLOSED
CORRECT
PARTLY CLOSED
INCORRECT
Figure 3.3 Operating Positions of Bi-fold Doors
C. Fuel
WARNING! For use with solid wood fuel only.
Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).
1. Hardwood vs. Softwood
Your fireplace’s performance depends on the quality of the firewood you use. One species of wood varies very little to the other in terms of energy content. All seasoned wood contains about 8,000 BTU’s per pound.
Hardwoods have a greater density than softwoods; a piece of hardwood will contain about 60% more BTU’s than an equal size piece of softwood. A cord of seasoned oak (hardwood) would contain about 60% more potential energy than a cord of seasoned pine (softwood).
Most softwoods are coniferous. These are trees with needle-like leaves that stay green all year and carry their seeds exposed in a cone. Examples of coniferous trees are Douglas fir, pine, spruce and cedar. Softwoods, being more porous, require less time to dry, burn faster and are easier to ignite than hardwoods.
Hardwoods are deciduous trees, broadleaf trees that lose their leaves in the fall. Their seeds are usually found within a protective pod or enclosure. Some examples of deciduous trees are oak, maple, apple, and birch. However, it should be noted that there are some deciduous trees that are definitely not considered hardwoods such as poplar, aspen and alder. Hardwoods require more time to season, burn slower and are usually harder to ignite than softwoods. Obviously, you will use the type of wood that is most readily available in your area. However, if at all possible the best arrangement is to have a mix of softwood and hardwood. This way you can use the softwood for starting the fire, giving off quick heat to bring the fireplace up to operating temperature. Add the hardwood for slow, even heat and longer burn time.
Soft woods
• Douglas Fir
• Pine
• Spruce
• Cedar
• Poplar
• Aspen
• Alder
Hard woods
• Oak
• Maple
• Apple
• Birch
10 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
WARNING! Risk of Fire!
• DO NOT burn wet or green wood.
• Wet, unseasoned wood can cause accumulation of creosote.
2. Moisture content
The majority of the problems fireplace owners experience are caused by trying to burn wet, unseasoned wood. Freshly cut wood can be as much water as it is wood, having a moisture content of around 50%. Imagine a wooden bucket that weighs about 8 pounds. Fill it with a gallon of water, put it in the firebox and try to burn it. This sounds ridiculous but that is exactly what you are doing if you burn unseasoned wood. Dead wood lying on the forest floor should be considered wet, and requires full seasoning time. Standing dead wood can be considered to be about two-thirds seasoned, if cut at the dry time of the year.
Burning wet, unseasoned wood will produce less heat output because it requires energy in the form of heat to evaporate the water trapped inside. This is wasted energy that should be used for heating your home. This moisture evaporates in the form of steam which has a cooling effect in your firebox and chimney system.
When combined with tar and other organic vapors from burning wood it will form creosote which condenses in the relatively cool firebox and chimney.
Even dry wood contains at least 15% moisture by weight, and should be burned hot enough to keep the chimney hot for as long as it takes to dry the wood out
- about one hour. To tell if wood is dry enough to burn, check the ends of the logs. If there are cracks radiating in all directions from the center, it is dry. If your wood sizzles in the fire, even though the surface is dry, it may not be fully cured.
3. Seasoning
Seasoned firewood is nothing more than wood that is cut to size, split and air dried to a moisture content of around 20%. The time it takes to season wood varies from around nine months for soft woods to as long as eighteen months for hardwoods. The key to seasoning wood is to be sure it has been split, exposing the wet interior and increasing the surface area of each piece.
A tree that was cut down a year ago and not split is likely to have almost as high a moisture content now as it did when it was cut.
To season wood:
• Cut logs to size
• Split to 6 in. (152 mm) or less
• Air dry to a moisture content of around 20%
- Soft wood - about nine months
- Hard wood - about eighteen months
Seasoning time may vary depending on drying conditions.
4. Storing Wood
Splitting wood before it is stored reduces drying time.
The following guideline will ensure properly seasoned wood:
• Stack the wood to allow air to circulate freely around and through the woodpile.
• Elevate the woodpile off the ground to allow air circulation underneath.
• The smaller the pieces, the faster the drying process.
Any piece over 6 in. (152 mm) in diameter should be split.
• Wood should be stacked so that both ends of each piece are exposed to air, since more drying occurs through the cut ends than the sides. This is true even with wood that has been split.
• Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process. Avoid covering the sides and ends completely. Doing so may trap moisture from the ground and impede air circulation.
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 11
5. Burning Process
Fire requires fuel, air and heat. If heat is robbed from the fireplace during the drying stage, the new load of wood has reduced the chances for a good clean burn.
Always burn dry, seasoned firewood.
6. Creosote Formation
When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a newly-started or a slow-burning fire. As a result, creosote residue accumulates on the flue lining.
When ignited, creosote creates an extremely hot fire which may damage the chimney or even destroy the house.
The chimney shall be inspected at least annually before lighting, or once every two months during heating season.
When creosote has accumulated it shall be removed to reduce the risk of a chimney fire.
7. Processed Solid Fuel Firelogs
Manufactured firelogs may be used with this fireplace.
Hearth & Home Technologies recommends the use of
UL Classified processed fuel firelogs. Follow the manufacturer’s lighting and safety instructions.
Using firelogs may require more frequent chimney inspections and cleaning.
Do not poke or stir the logs while they are burning. Use only firelogs that have been evaluated for the application in manufactured fireplaces and refer to firelog warnings and caution markings on packaging prior to use.
D. First Fire
Before lighting your first fire in the fireplace, make certain that:
• refractory is in place
• all labels have been removed
E. Lighting Instructions
NOTICE: You must establish a good draft to prevent smoke spillage into the room.
The first three or four fires should be of moderate size to allow the oils and binders to be burned from the fireplace and the refractory and paint to cure. You may notice an industrial odor the first few fires. This is considered normal.
Use well-seasoned wood.
• Open the flue damper to a fully open position.
• Place crumpled or twisted paper under the fireplace grate.
• Loosely arrange kindling or small pieces of wood to form a ‘tent’ on the fireplace grate.
• Pre-warm the flue to establish a draft to help reduce smoke spillage during start-up. Hold a rolled up piece of burning newspaper under the flue damper for a few moments.
• Light the crumpled paper to ignite the kindling.
• Add small pieces of wood until a hot bed of embers has been established.
• Add a minimum of three average size pieces of split firewood, placed to allow combustion air and flames between them.
WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace.
DO NOT:
• store flammable materials close to the fireplace
• use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace.
12 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
4
Maintenance and Service
WARNING! Hot Surfaces!
Glass and other surfaces are hot during operation AND cool down. DO NOT clean fireplace until it is cooled.
Installation and repair should be done by a qualified service technician only. The fireplace should be inspected before use and at least annually by a professional service person.
►
The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please contact your dealer for a service appointment.
Risk of Asphyxiation and Fire! Annual inspection by qualified technician recommended.
Check:
• condition of doors, surrounds and fronts
• condition of glass and glass assembly
• obstructions of combustion and ventilation air
• obstructions of termination cap
Clean:
• glass
• air passageways, grilles
A. Chimney Inspection
Frequency: As necessary; at least annually before lighting fireplace, or once every two months during heating season.
By: Homeowner/Chimney Sweep
• Confirm that termination cap remains clear and unobstructed.
• Inspect for blockages such as bird nests, leaves, etc.
• Inspect for corrosion or separation.
• Inspect for creosote and remove as needed, at least every two months during the heating season.
• Inspect the system at the fireplace connection and at the chimney top.
In the event of a chimney fire, Hearth & Home Technologies recommends replacement of the chimney and inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria.
B. Creosote (Chimney) Cleaning
Frequency: As needed; at least annually before lighting, or once every two months during heating season.
When creosote has accumulated it shall be removed to reduce the risk of a chimney fire.
By: Chimney Sweep
Needed: Brush, Phillips screwdriver
• When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire.
• Remove all ash from the firebox and extinguish all hot embers before disposal. Allow the fireplace to cool completely.
• Close the door tightly.
• Remove the top of the termination cap as shown in
Figure 4.1 to clean the cap and chimney.
• The creosote or soot should be removed from the chimney with a brush specifically designed for the size of chimney in use.
• Reinstall termination cap.
• Clean out fallen debris from the firebox.
Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.
1. REMOVE (8) SCREWS
2. LIFT TOP
Remove screws, lift top cover.
Top Cover
Remove 4 screws and lift top pan off.
Remove 2 screws from the front and back and lift the top off.
TOP
Cap Cap
Chimney
SCREW
Slip
Section
TR11/TR11T
TR444/TR442
Round Termination Cap
ST1175
ST475
Square Termination Cap
TCT1175
Terra Cotta
Termination Cap
Available US only
Figure 4.1 Chimney & Termination Cap Cleaning
DT SERIES
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
TOP
SCREW
13
C. Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
• Warping or sagging 1-1/2 in. (38 mm) or more
• Broken welds
• Burn-through of grate bars
For safe operation, replace only with the approved grate from Hearth & Homes Technologies.
D. Glass Cleaning
Frequency: As necessary
By: Homeowner
• Clean glass with a non-abrasive glass cleaner. Use a damp cloth dipped in wood ashes or a commercially available oven cleaner. Remove any oven cleaner residue with a glass cleaner or soap and water.
E. Ash Removal
Frequency: As necessary
By: Homeowner
Needed: Covered metal container, metal shovel, fireplace broom
Risk of Fire! DO NOT remove ashes until the fire is out and the fireplace is cold.
• Ashes should be placed in metal container with tight fitting lid.
• The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal.
• If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
F. Refractory/Firebrick
Frequency:
By:
• Inspect condition of brick. Replace if crumbly or otherwise deteriorated, or if cracks exceed 1/4 in.
(6 mm).
14 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
5
Troubleshooting
Start Fire Problems
Can’t get fire started
Excessive smoke or spillage
Burns too slowly
Smolders, sizzles
Possible Cause
Not enough kindling/paper or no kindling/paper
Damper closed/not fully open
Not enough air for fire to ignite
Solution
Use dry kindling, more paper. Arrange kindling & wood for air movement.
Open damper.
Check for restricted cap/shroud.
Open air kit (if installed).
Check for flue blockage.
Pre-warm flue before starting fire (refer to starting fire section).
Check for adequate vent height (refer to chimney assembly section).
Open window below the fireplace towards the wind.
Wood condition is too wet, too large Use dry, seasoned wood (refer to wood fuel section).
Bed of coals not established before adding wood
Flue blockage such as birds’ nests or leaves in termination cap
Start with paper & kindling to establish bed of coals (refer to starting fire section).
Have chimney inspected for creosote and cleaned by a certified chimney sweep.
Fire burns too fast
Down draft or negative pressure
Competition with exhaust devices
Extremely dry or soft wood
No glass doors
Overdrafting
Do not use exhaust fans during start-up (refer to negative pressure section).
Open window below the fireplace towards the wind.
Mix in hardwood.
Mix in less seasoned wood after fire is established (refer to wood fuel section).
Add glass doors to slow down air flow.
Check for correct vent height; too much vertical height creates overdrafting.
Check location of vent termination (refer to chimney assembly section).
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 15
A. FAQs
Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by inadequate draft due to environmental conditions, down drafts, tight sealing construction of the structure, or mechanical exhausting devices which will create a negative air pressure within the structure where the fireplace is located.
If smoke spillage occurs from a fireplace opening when the door is open, there is either a leakage in the flue, a blockage in the flue, or some condition is affecting draft
Understanding and differentiating the conditions which can cause each of these kinds of spillage problems is essential to their solution.
• Flue Leakage
Check for improperly connected flue joints or a damaged flue joint in the chimney system. Such leakage would reduce draft (air would be drawn in through the leaks rather than through the fireplace).
The result might be difficult start-up and smoky fires that might spill if other adverse draft conditions accompany this problem.
• Flue Blockage
The damper should be open.
Check for objects that may have fallen down the chimney.
Flue draft is measured as negative pressure in the chimney. The amount of negative pressure determines how strong the draft is. The draft is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney.
There are three basic criteria essential in establishing and maintaining flue draft:
• availability of combustion air
• heat generated from the fire
• diameter and height of the flue system
These three factors work together as a system to create the flue draft. Increasing or decreasing any one of them will affect the other two and thus change the amount of draft in the entire system.
If the fire is hard to start and smoke spills out of the fireplace, or you find it difficult to establish and maintain a moderately high burn rate, then the flue draft is too low and corrective measures must be taken.
Be sure you have air available for combustion and that your firewood is dry and well seasoned. Build your fires properly and according to the instructions given in operating instructions, “Starting a Fire”. Be sure your flue system is installed correctly and that it is the proper diameter and height. Check for the following:
• All chimney sections are properly installed.
• The chimney is clean and free of creosote or soot buildup.
• Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney and the chimney is free of debris from animals.
• Ensure the chimney cap is clean and free of any buildup of soot or creosote if cap is equipped with a spark arrestor screen.
• The wood being used in dry and well seasoned.
If you still suspect you have a low draft problem it may be necessary to increase the volume of air in your flue system. Since the diameter of your flue system is matched with the size of the flue collar and should not be changed, then the height of the system must be increased. Add chimney sections one at a time until the draft improves.
In some cases, regardless of what you do, it can still be difficult to establish the proper flue draft. This is especially evident when using an exterior factory-built chimney or exterior masonry chimney. Try holding a burning rolled up newspaper as close to the flue outlet as possible for a few minutes, then light the paper under the kindling. The heat generated from the burning rolled up newspaper should help get the draft established.
Still other factors can affect how well your flue system performs. Neighboring structures, high winds, tall trees, even hillsides can affect air currents around the chimney. Well designed chimney caps are available that can help. Your fireplace dealer is the local expert in your area. He can usually make suggestions or discover problems that can be easily corrected allowing your fireplace to operate correctly as it has been designed, providing safe and economical heat for your home.
► Contact your dealer for additional information regarding operation and troubleshooting. Visit www.heatnglo.com to find a dealer.
16 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
Overhead fan operating?
Strong
wi nd s a ro un d ch imney term inat ion
?
Another appliance in home also exhausting air (furnace, fan, dryer, etc.)?
Unsealed can lights?
Air register from furnace near fireplace?
Doors opening and closing?
Window closed for start-up?
Combustion air control
Outside air closed?
Overhanging tree?
Bird's nest or leaves in termination cap?
Structural changes in chimney area?
Creosote buildup in flue?
Figure 5.1 Factory-built Fireplaces: Troubleshooting
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 17
►
6
Reference Materials
A. Service Parts
Stocked at Depot
Stocked at Depot
42 in. See-thru W
18 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
B. Accessories
Doors
Gas Log Sets
Gas Log Lighters
DM1242 Bi-fold Doors with Black Trim
DM1242S Bi-fold Doors with Stainless Steel Trim
Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13 19
C. Contact Information
Please contact your Heat & Glo dealer with any questions or concerns.
For the number of your nearest Heat & Glo dealer, please visit www.heatnglo.com.
– NOTES –
CAUTION
• Important operating and maintenance instructions included.
DO NOT DISCARD THIS MANUAL
• Read, understand and follow these instructions for safe installation and operation.
• Leave this manual with party responsible for use and operation.
This product may be covered by one or more of the following patents: (United States) 5000162, 5016609, 5076254, 5113843,
5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5413089, 5429495, 5452708, 5542407, 5890485, 5931661, 5941237,
5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226,
6484712, 6543698, 6550687, 6601579, 6672860, 6688302, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942,
6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,7047962,
7216645, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.
Printed in U.S.A. - Copyright 2012
20 Heat & Glo • HST48D Owners Manual • 4012-055 • Rev B • 07/25/13
advertisement
Key Features
- Wood burning
- Safety features
- Operating instructions
- Maintenance tips
- Troubleshooting guide