6RU Rack Mountable Solid State Power Amplifiers

6RU Rack Mountable Solid State Power Amplifiers
6RU Rack Mountable
Solid State Power Amplifiers
FEATURES
•
•
•
•
•
•
•
•
1.1 kW C-Band High Power SSPA
DESCRIPTION
Teledyne Paradise Datacom’s Indoor, High Power Rack
Mount (R) series SSPAs represent the industry’s highest power
density and most reliable high power amplifier systems. These
high power amplifiers are accompanied with a separate power
supply chassis.
OPTIONS
•
•
•
•
•
•
•
The power supply is configured as a n+1 redundant, hot
swappable, power supply comprised of three modules. Only two
modules are required to operate the HPA, therefore one module
is redundant. In the event of a power supply module failure, the
amplifier system will not fail. The module can then be changed
without ever taking the HPA out of service. The microwave
amplifier architecture is also designed for maximum soft fail
redundancy.
The High Power Rack Mount SSPA employs a modular design,
which allows quick and easy replacement in the event of a
catastrophic failure of one of the SSPA components. These
modular assemblies include: front and rear fan trays; and a rear
panel controller card.
Teledyne Paradise Datacom
328 Innovation Blvd., Suite 100
State College, PA 16803
Tel: (814) 238-3450
Fax: (814) 238-3829
1 OF 9
www.paradisedata.com
Extremely High Power
Density:
1.1 kW C-Band;
to 1000W X-Band;
to 500W Ku-Band.
Hot Swap, n+1 Redundant
Power Supply
Power Factor Corrected
Power Supply
Modular (soft-fail)
Architecture
Removable fan assemblies
Ethernet Port
RF Output Sample Port
(-40 dB)
Built-in 1:1 Redundancy
Control
Extended Frequency Band
L-Band Input operation
Reflected Power Monitor
Phase Combined Systems
Remote Control Panel
RF Input Sample Port
(-10 dB)
Rear Panel Air Intake and
Exhaust
SPECIFICATIONS
•
•
•
•
SSPA Chassis housing:
19.0 X 10.47 X 30.0 in
483 X 266 X 762 mm
180 lbs / 82 kg
3RU Power Supply:
19.0 X 5.25 X 15.44 in
483 X 134 X 433 mm
50 lbs / 23 kg
Gray powder coat finish
Operating temperature:
0 to +50 °C
Teledyne Paradise Datacom
1 Wheaton Road, Witham
Essex CM8 3UJ England
Tel: +44(0) 1376 515636
Fax: +44(0) 1376 533764
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
Power Specifications
BAND
PARAMETER
Frequency Range
C-BAND
Output Power @: Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Power Factor
Line Power
NOTES
LIMITS
UNITS
(see options for extended band)
5.850 to 6.425
GHz
HPAC6750ARXXXXX
HPAC611KARXXXXX
Psat / P1dB
58.7 / 58.0 (750 / 630)
60.4 / 60.0 (1100 / 1000)
dBm (W)
dBm (W)
VAC
Hz
HPAC6750ARXXXXX
HPAC611KARXXXXX
180 to 265
47 to 63
.90
4150
6000
7.9 to 8.4
GHz
HPAX6700ARXXXXX
HPAX610KARXXXXX
Psat / P1dB
58.5 / 58.1 (700 / 650)
60.0 / 59.5 (1000 / 900)
dBm (W)
dBm (W)
VAC
Hz
HPAX6700ARXXXXX
HPAX610KARXXXXX
180 to 265
47 to 63
.90
5500
6000
(see options for extended band)
14.0 to 14.5
GHz
HPAK6400ARXXXXX
HPAK6500ARXXXXX
Psat / P1dB
56.0 / 55.0 (400 / 300)
57.0 / 56.0 (500 / 400)
dBm (W)
dBm (W)
Power Factor Corrected
HPAK6400ARXXXXX
HPAK6500ARXXXXX
180 to 265
47 to 63
.90
4600
5100
Frequency Range
X-BAND
Output Power @: Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Power Factor
Line Power
Frequency Range
KU-BAND
Output Power @: Saturation/P1dB
(Typical/Guaranteed minimum)
Power Requirements
Line Voltage
Line Frequency
Power Factor
Line Power
W
W
W
W
VAC
Hz
W
W
Options
Extended C-Band
5.850 to 6.725 GHz
5.750 to 6.670 GHz
Extended Ku-Band
13.75 to 14.5 GHz
De-rate power by 1.0 dB linearly from 6.425 to 6.725 GHz
De-rate power by 1.0 dB linearly from 6.425 to 6.670 GHZ and by
0.5 dB from 5.750 to 5.850
De-rate power by 1.0 dB linearly from 13.75 to 14.0 GHz
HPAC6XXXBRXXXXX
HPAC6XXXCRXXXXX
HPAK6XXXBRXXXXX
Reflected Power Monitor
See Configuration Matrix
Block Up Converter (BUC)
See Configuration Matrix
RF Input Sample Port (-10 dB)
See Configuration Matrix
2 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
General Specifications: 6RU RM Series
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Variation vs. Temperature
Gain Adjustment
Intermodulation Distortion
AM/PM Conversion
Spurious
Harmonics
Input/Output VSWR
Noise Figure
Group Delay
(per 40 MHz segment)
Noise Output
Residual AM Noise
NOTES
LIMITS
UNITS
minimum
full band
Extended C-Band units
per 40 MHz
0oC to +55oC
0.1 dB resolution
adjustable by either serial or analog
voltage input: 0.5 to 2.5 VDC
75
±1.0
±1.5
+0.3
±1.0
20
dB
dB
dB
dB/40 MHz
dB
dB
3dB back off relative to P1dB
-25
dBc
(@ rated P1dB)
(@P1dB-3dB)
3.5
0.5
°/dB
°/dB
(@ rated P1dB)
(@ rated P1dB-3dB)
-60
-50
dBc
dBc
All units except Extended C-Band
Extended C-Band units1
1.30:1
1.50:1
at maximum gain
12
dB
Linear
Parabolic
Ripple
0.01
0.003
1.0
ns/MHz
ns/MHz2
ns p-p
TX Band (C-, X- or Ku-Band)
RX Band (C- or Ku-Band)
RX Band (X-Band)
-75
-150
-100
dBW/4 KHz
dBW/4 KHz
dBW/4 KHz
0 - 10 KHz
10 KHz - 500 KHz
500 KHz - 1 MHz
-45
-20 (1.25 + log F)
-80
dBc
dBc
dBc
Phase Noise
IESS –308/309 - 10 dB
Mechanical
Size
HPA Chassis
Power Supply Chassis
19.0 X 10.47 X 30.0
483 X 266 X 762
inches
mm
19.0 X 5.25 X 15.44
483 X 134 X 433
inches
mm
180 (82)
50 (23)
lbs.(kg)
lbs.(kg)
powder coat
Gray
Ambient
0 to +50
°C
Condensing
95
%
Integrated
Forced air
width X height X depth
width X height X depth
Weight
HPA Chassis
Power Supply Chassis (3RU)
Finish
Environmental
Operating Temperature
Relative Humidity
Cooling System
1
Extended C-Band units may meet 1.30:1 as a special option. Discuss with your sales representative.
Specifications are subject to change.
3 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
Interface Specifications; 6RU RM Series
PORT
NOTES
LIMITS
PIN-OUT
Parallel Port Outputs
Power Supply Fault
Auxiliary Fault
Mute
BUC Fault
Temperature Fault
Voltage Fault
DC Current Fault
Low RF Fault
Form C relay
Form C relay
Form C relay
Form C relay
Form C relay
Form C relay
Form C relay
Form C relay
Parallel Port Inputs
Mute Input
Local / Remote
Fault Clear
Standby Select
Auxiliary Fault
Ground
Opto Isolator
Opto Isolator
Opto Isolator
Opto Isolator
Opto Isolator
Main Serial Port (J4)
RS232 / RS485
DB9 (F)
RS232 Out, RS485 TXRS232 In, RS485 RXRS485 RX+
RS485 TX+
Service Request 1
Service Request 2
Service Request Common
Termination
Ground
Pin 2
Pin 3
Pin 4
Pin 1
Pin 6
Pin 8
Pin 7
Pin 9
Pin 5
Auxiliary Serial Port (J5)
RS232 / RS485
DB9 (F)
RS232 In, RS485 RXRS232 Out, RS485 TXRS232 DTR, RS485 TX+
RS485 RX+
Termination
Ground
Pin 2
Pin 3
Pin 4
Pin 1
Pin 9
Pin 5
1:1 Redundant System Control Link
DB9 (F)
RS485+
RS485Link Out
Link In
Ground
Pin 1,4
Pin 2,3
Pin 6,7
Pin 8,9
Pin 5
Redundant Switch Control
Molex (43810-0002)
+28 VDC
RF Switch 1, pos 1
RF Switch 1, pos 2
RF Switch 2, pos 1
RF Switch 2, pos 2
Pin 1,4
Pin 3
Pin 2
Pin 6
Pin 5
Program Port (J6)
Flash Firmware Program Port
DB25(F)
-
Ethernet Port (J9)
RJ45
TX+
TXRXRX+
Ground
Pin 1
Pin 2
Pin 3
Pin 6
Pins 4,5,7,8
RF Input, Input & Output Sample
RF Output
HPAK6XXXR
HPAC6XXXR
HPAX6XXXR
Line Power
Type N
Female
WR75 Waveguide
WR137 Waveguide
WR112 Waveguide
(3) IEC feeds
Grooved (PBR-120)
CPR137G flange
CPR112G (PDR-84)
Plug
Monitor & Control (J7)
Parallel Port Outputs
Monitor & Control (J7)
Parallel Port Inputs
Link Port (J8)
Switch Port (J3)
Connectors
4 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
L-Band Operation
Teledyne Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band
Block Up Converter. The L-Band units utilize Paradise Datacom’s proprietary ZBUCTM
technology. The addition of a ZBUC converter to a 6RU Rack Mountable SSPA typically
increases the gain by 2-4 dB. The advantages of ZBUCTM technology include:
TM
• ZBUC converter can detect and switch to an extenally supplied reference.
• Optional internal high stability (10MHz) reference.
TM
• ZBUC converter can lock to an externally supplied reference of 5, 10, 20, 25, or 50 MHz
without modification.
TM
• ZBUC converter can accept a wide range of external reference power (-10 to +5 dBm)
TM
• ZBUC
converter can accept FSK monitor and control signal via the IFL for complete
amplifer remote control.
Available Frequency Plans
Band
Frequency Band
IF Input
LO Frequency
RF Output
Gain Change
C
Standard C-Band
950 - 1525 MHz
4.900 GHz
5.850 - 6.425 GHz
0-4 dB
C
Extended C-Band
950 - 1825 MHz
4.900 GHz
5.850 - 6.725 GHz
0-4 dB
C
Palapa Band
950 - 1250 MHz
5.475 GHz
6.425 - 6.725 GHz
0-4 dB
C
Insat Band
950 - 1250 MHz
5.775 GHz
6.725 - 7.025 GHz
0-4 dB
C
Extended C-Band 2
950 - 1675 MHz
4.800 GHz
5.750 - 6.475 GHz
0-4 dB
X
Standard X-Band
950 - 1450 MHz
6.950 GHz
7.900 - 8.400 GHz
0-2 dB
Ku
Standard Ku-Band
950 - 1450 MHz
13.050 GHz
14.00 - 14.50 GHz
0-2 dB
Ku
Extended Ku-Band
950 - 1700 MHz
12.800 GHz
13.75 - 14.50 GHz
0-2 dB
Electrical Specifications for 6RU RM SSPA with ZBUCTM converter
PARAMETER
Gain
Gain Flatness
Gain Slope
Gain Adjusted Range
Gain Stability
Phase Noise
Spurious
NOTES
LIMITS
UNITS
Nominal setting
full band (C-,X-,Ku-bands)
per 40 MHz (C-,X-,Ku-bands)
75
±2.0
±0.5
20
60 - 80
57 - 77
±1.5
dB
dB
dB/40 MHz
dB
dB
dB
dB
Typical C-Band Adj. Range
Typical Ku-Band Adj. Range
-40 to +60 °C
Offset frequency from carrier
10 Hz
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Absolute max.
-30
-60
-70
-80
-90
-90
C-band (typ.)
-60
-80
-80
-85
-120
-125
In-Band Signal Related (C-/Ku-Band)
(Extended C-Band)
Close to Carrier Spurious (< 20 MHz)
Local Oscillator
Non-Signal Related
X-band (typ.)
-60
-75
-75
-100
-110
-122
Ku-band (typ.)
-50
-65
-72
-90
-110
-120
-50
-40
-50
-30
-40
dBc
dBc
dBc
dBm
dBm
dB
Noise Figure
At 75 dB gain setting
20
Input VSWR
L-Band
1.5 : 1
Reference accuracy @ 25 °C
Reference Stability over Temperature (-40 to +40 °C)
±1 • 10-8
±1 • 10-9
Internal Reference Option
5 OF 9
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
Power Supply Options
The 6RU Chassis may be fitted with a variety of power supply options. The dual 1RU power
supply configuration provides redundancy with all power levels; or may be used as a nonredundant supply by utilizing fewer power supply modules. The stand-alone 1RU power
supply can be used to power the 750W C-Band or 400W Ku-Band chassis. The standard
3RU, three-module power supply offers redundancy for all power levels. See the table below.
POWER SUPPLY CONFIGURATIONS
1RU NON-REDUNDANT
(750W C-Band & 400W KU-Band only)
PS1
MOD
MOD
MOD
MOD
DUAL 1RU
(Redundant for 750W C-Band & 400W
Ku-Band; Non-redundant for others)
PS1
MOD
PS2
MOD
MOD
MOD
BLANK BLANK
MOD
MOD
Note: Single pair of DC cables between
PS2 and SSPA
DUAL 1RU REDUNDANT
(All power levels)
PS1
MOD
MOD
MOD
MOD
PS2
MOD
MOD
MOD
MOD
Note: Two pair of DC cables between
PS2 and SSPA
3RU REDUNDANT
(All power levels)
PS1
MOD
MOD
-12VDC
+12VDC
IN
IN
MOD
PS1
BLANK
BLANK
PS2
This configuration offers redundancy for the
750W C-Band and 400W Ku-Band units.
Outline Drawing, 6RU RM SSPA Chassis and dual 1RU Non-redundant Power Supply
6 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
-12VDC
+12VDC
IN
IN
Outline Drawing, 6RU RM SSPA Chassis and 1RU Non-redundant Power Supply
7 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
-12VDC
+12VDC
IN
IN
Outline Drawing, 6RU RM SSPA Chassis and 3RU Redundant Power Supply
8 OF 9
202059 REV AE
ECO 16421
6RU Rack Mountable
Solid State Power Amplifiers
HPA
Part Number Configuration Matrix
6
R
Band
C - C-Band
X - X-Band
K - Ku-Band
Configuration Modifier
XXX = Standard (3RU Redundant
Power Supply)
DXX1 = Non-redundant 1RU Power
Supply
EXX1 = Non-redundant 1RU Power
Supply & Input Sample Port
FXX = (2) 1RU Power Supplies,
Non-redundant2
GXX = (2) 1RU Power Supplies,
Non-redundant2 & Input
Sample Port
HXX = (2) 1RU Power Supplies,
Redundant
JXX = (2) 1RU Power Supplies,
Redundant & Input Sample
Port
SXX = Input Sample Port
XVX = Reflected Power Monitor
XXE3 = Rear Panel Exhaust Adapters
XXK3,4 = Rear Panel Exhaust Adapters
& Receive Band Reject Filter
XXR4 = Receive Band Reject Filter
Power Level
(in Watts)
C-Band
750, 1100 (11K)
X-Band
700, 1000 (10K)
Ku-Band
400, 500
Frequency Sub Band
C-Band
A1 - 5.85 - 6.425 GHz
B1 - 5.85 - 6.725 GHz
C - 5.750 - 6.670 GHz
E1 - 6.425 - 6.725 GHz (Palapa)
F1 - 6.725 - 7.025 GHz (Insat)
G1 - 5.750 - 6.475 GHz
V1,2 - 5.85 - 6.725 GHz
X-Band
A1 - 7.90 - 8.40 GHz
B - 7.50 - 8.50 GHz
C - 9.50 - 10.50 GHz
D - 7.70 - 8.40 GHz
Ku-Band
A1 - 14.00 - 14.50 GHz
B1 - 13.75 - 14.50 GHz
1
2
Available with optional BUC
With 1.3:1 VSWR.
Package
1
Only available with 750W C-Band; 400W Ku-Band.
Redundant with 750W C-Band; 400W Ku-Band.
3
Not available with package options Y and Z.
4
S-Band only.
2
System Configuration
X = Standalone
See the following datasheets system options:
• Indoor Redundant SSPA Systems (203583)
•
Indoor Phase Combined SSPA Systems (203584)
R = Rack Mount (Standalone)
Block Up Converter
B = BUC (Custom)
M = Internal Reference ZBUC
P = External Reference ZBUC
X = N/A
Example - A standalone 500W Extended Ku-Band high power rack mount SSPA with an
optional input sample port and no block up converter is part number: HPAK6500BRXXSXX.
Specifications listed in this document are subject to change without notice.
9 OF 9
202059 REV AE
ECO 16421
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement