- Computers & electronics
- Data input devices
- Numeric keypads
- Kaba
- E-PLEX 2000
- Operation manual
- 16 Pages
Kaba E-PLEX 2000 Operation Manual
Kaba E-PLEX 2000 is an advanced electronic push-button lock designed for access control in various applications. It offers customizable access codes with a length of 4 to 8 digits, providing enhanced security. The lock can be programmed with different user levels, including Master, Manager, Service User, and User, allowing for flexible access control. It features tamper alarms, lockout mode, and adjustable buzzer volume for added security and convenience. The lock's passage mode can be activated or deactivated, and its duration can be programmed as needed.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Kaba Access Control
2941 Indiana Avenue Winston-Salem, NC 27105 USA
Tel: (800) 849-8324 (336) 725-1331
Fax: (800) 346-9640 (336) 725-3269 www.e-plexlock.com • www.kaba-ilco.com
PK3173 0306
E-PLEX 2000
Operations Manual
2
TABLE OF CONTENTS
States of the Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Factory Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Access Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Pushbutton Programming Mode . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Sequence of Operations for Start-Up Programming . . . . . . . . . . . .4
Default Values of the E-Plex 2000 Programmable Parameters . . . .5
Configuring the Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
General Procedure for Pushbutton Programming . . . . . . . . . . . . . .6
Reset Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Procedure 1 - Program the Access Code Length . . . . . . . . . . . . . .7
Procedure 2 - Modify the Master User Access Code . . . . . . . . . . .8
Procedure 3 - Program the Unlock Time . . . . . . . . . . . . . . . . . . . . .8
Procedure 4 - Program the Duration of the . . . . . . . . . . . . . . . . . . .9
Passage Mode Period
Procedure 5 - Program the Lock for Tamper Time Parameters . .10
Procedure 6 - Programming the Lock for Keypad . . . . . . . . . . . . .11
Buzzer Volume
Users - General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
User Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
User Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
User Access Codes (PINs) - Examples . . . . . . . . . . . . . . . . . . . . .13
Procedure 1 - Add / Modify a User Access Code . . . . . . . . . . . . .14
Procedure 2 - Add / Modify a Manager Access Code . . . . . . . . . .14
Procedure 3 - Add / Modify Service User Access Code . . . . . . . .15
Procedure 4 - Delete User Access Codes . . . . . . . . . . . . . . . . . .19
Procedure 5 - Delete Manager Access Codes . . . . . . . . . . . . . . .19
Procedure 6 - Delete Service User Access Codes . . . . . . . . . . . .20
Procedure 7 - Delete All Access Codes Except Master . . . . . . . .20
and Manager
Procedure 8 - Activate User Access Codes . . . . . . . . . . . . . . . . .21
Procedure 9 - Activate Manager Access Code . . . . . . . . . . . . . . .21
Procedure 10 - Activate Service User Access Code . . . . . . . . . . .22
Procedure 11 - Activate All User Access Codes . . . . . . . . . . . . . .22
TABLE OF CONTENTS (continued)
Procedure 12 - Activate / De-activate Passage Mode . . . . . . . . .23
Procedure 13 - De-activate User Access Codes . . . . . . . . . . . . . .23
Procedure 14 - De-activate Manager Access Codes . . . . . . . . . .24
Procedure 15 - De-activate Service User Access Code . . . . . . . .24
Procedure 16 - De-activate all Access Codes except . . . . . . . . . .25
Master and Manager
Procedure 17 - Activate / De-activate Lockout Mode . . . . . . . . . .25
Procedure 18 - Perform Manual Diagnostics . . . . . . . . . . . . . . . .25
Battery Life and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Summary of Pushbutton Programming Commands . . . . . . . . . . .27
Visual Feedback Message Definitions . . . . . . . . . . . . . . . . . . . . . . .30
User List Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
March 2006
A publication of Kaba Access Control
2941 Indiana Avenue
Winston-Salem, NC 27105
No part of this book may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from the Publisher.
The information contained in this publication is accurate to the best of Kaba Access
Control’s knowledge.
Specifications are subject to change without notice.
3
4
States of the Lock
Factory Mode
The factory mode is one of three primary states of the E-Plex 2000. The main characteristics of this state are:
• The E-Plex 2000 opens only when the 8-digit master combination (1-2-3-4-5-6-7-8) is keyed in.
• The visual indication for ‘access granted’ is green LED flashing once. A high-pitched tone is also generated while the green LED is on.
• The Master User must change the combination to be able to exit the factory mode, and switch to the access mode.
Access Mode
This mode refers to a lock that is operational for user access, and not in factory or Programming Mode.
Pushbutton Programming Mode
The E-Plex 2000 enters the Pushbutton Programming Mode when the user enters the master combination or one of the manager combinations, preceded and followed by the character ‘#’ (ex: #12345678#). Once the E-Plex 2000 is in the Pushbutton Programming Mode, the Master/
Manager can enter one or more command sequences. Each command sequence ends with a ‘#’ character that acts like an < enter > character.
At the very end of all sequences of programming commands, enter one more # to remove the lock from the Pushbutton Programming Mode to return to normal access mode.
Sequence of Operations for Start-Up Programming
What is the recommended sequence of operations?
With the E-Plex 2000 in the factory mode.
• Program the Access Code Length (default length is four digits).
The access code field length can only be changed when the lock is not activated (when still in the factory mode).
• Change factory Master to your own Master Code (always eight digits) to place lock in access mode.
Put lock in Pushbutton Programming Mode.
• Program the Unlock time.
• Program the Lock for the Duration of Passage Mode (if desired).
• Program the Lock for Tamper Time Settings.
• Program the Lock for Buzzer Volume.
• Add Access Codes as desired.
Default values of the E-Plex 2000 programmable parameters
Parameters
Lock state
Passage mode open time limit
Passage mode
Lockout mode
Unlock time
Buzzer volume control
Tamper shutdown time
Tamper attempt count
Access code length
Factory Default Values
Unprogrammed
9 hours
De-Activated
De-Activated
2 seconds
Low
30 seconds
4 attempts
4 digits
Master combination
Access code
Code status
12345678 (8 digits)
None
Activated
5
6
Configuring the Lock
General Procedure for Pushbutton Programming
1.
The pages that follow provide step-by-step instructions for programming the E-Plex 2000 lock.
2.
The general procedure for all programming functions is as follows: a. Put the lock in Programming Mode by pressing # Master
Code # b. Use the Summary of Commands Table in the appendix section of this guide to enter the three digit command sequence
(Command Type + Function Code), followed by #.
c. Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e. Once the lock is in programming mode, multiple command sequences can be entered without having to repeat the
#mastercode#. However, if there is no activity for 15 seconds at the keypad, the lock will automatically exit from programming mode.
For example
• If the Master or Manager enters his code of 87654321, the door will open.
• If he enters #87654321#, the lock will enter into the
Programming Mode and wait for the next part of the command.
• If he enters the # sign twice at the end of the code, for example #87654321##, the lock will go out of Programming
Mode and return to its normal mode.
Note: The # pound sign acts like the Enter key on a keyboard in your communications with the lock. The # tells the lock that one part of the entry is finished. The # serves another purpose - to distinguish a programming type command from a simple Access Code to open the door. A Master or Manager User can use the same number to open the door or to put the lock in Programming Mode, the only difference being that he uses the # sign in front to signal that he is about to enter a programming command. For increased security, it is recommended that the master user code not be used for everyday access. This can be accomplished by creating an access user code for the master user.
Reset Procedures
There are three different “Reset” levels available in the E-Plex 2000.
Code 099# will reset the lock to the factory default settings except for the access code length (Master and Manager User codes are retained if already programmed)
Code 299# will delete all access and service user codes (Master and
Manager users are retained)
Hard Reset will return the lock to factory mode including deleting all codes, putting the lock back to factory default values (4 digit access code length) and making the master code 1-2-3-4-5-6-7-8. A hard reset is performed as follows.
Resetting a Lock to Factory-Default: (lock must be powered)
• On the inside or back housing, remove the top right screw holding the lock to the door.
• Insert a long non-metallic blunt ended tool in the screw hole to press and release the Reset-to-Factory-Default button. You will hear the motor turning if successful, meaning the lock has reset.
Procedure 1 - Program the Access Code Length
Setting the length of Access Codes must be the first lock programmable function you perform, because all your other access codes must have the same length. If a user enters a code of a different length, the lock will not accept it. Longer length Access Codes permit a greater number of code possibilities, and thus higher security. The master code must always be 8 digits
Required User Level: Master
1.
To configure the E-Plex 2000 programmable pushbutton lock, it must first be placed in Programming Mode.
Important: This is the only programmable function that can be done during the factory mode using the factory master code. Except for changing from the factory code to a new master code.
2.
Enter the E-Plex 2000 factory Master (Programming) Code
( #12345678#). The lock responds with a flashing green light. If
1-2-3-4-5-6-7-8 does not seem to work, please follow the steps to perform a hard reset by following the procedure in on page 7.
7
3.
Enter the code 009 #LL #, where LL represents the length
(number of digits in a code). The range is from 04 to 08 digits.
You can leave the factory default Access Code length
(4 digits) if you wish.
4.
Example of Complete Entry: 009#05#.
5.
Key in another # to indicate the end of programming.
6.
From now on, all the Access Codes you create must be the length specified in this step, which is 5 digits.
Procedure 2 - Modify the Master User Access Code
Required User Level: Master
1.
To change the factory code or current Master Code, follow the next three steps:
2.
Put lock into Pushbutton Programming Mode.
3.
Use the command, 000, for Master, then the new Master
Code number.
4.
You must use 8 digits between 00000000 and 99999999 as follows:
000#MMMMMMMM#, we’ll use 000#87654321# as an example.
5.
Enter the Master Code again 87654321# for confirmation.
6.
Example of Complete Entry: 000#87654321#87654321#.
7.
Key in another # to indicate the end of programming.
8.
After that, you will always use your own Master Code. Please write the code down and keep in a safe place. The factory code is no longer valid.
Required User Level: Master
8
Procedure 3 - Program the Unlock Time
Unlock time is the length of time the door will remain unlocked when a correct code is entered before automatically re-locking itself.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
To establish Unlock Time, enter the following code: 004#TT#,
where TT is the time in seconds, (TT=02 to 20 seconds, for example 10 seconds).
3.
Example of Complete Entry: 004#10#.
4.
Enter another # to indicate the end of programming.
5.
You have now programmed an Unlock Time of 10 seconds for the door.
Procedure 4 - Program the Duration of the Passage
Mode Period
You might want to program locks for public areas, such as cafeterias, to have free access (Passage Mode) during certain periods of the day, and revert to required code access outside of these regular hours.
The length of time that the lock remains in Passage Mode is programmable.
The factory default length of time for Passage Mode is 9 hours - you may leave the default.
Once the lock has been put into Passage Mode, it will automatically relock after the designated duration.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter command code 005#.
3.
Then TT#, where TT= 01 to 24 hours.
4.
A TT entry of 00 means there is no time limit - the door remains unlocked.
5.
Enter 005 #TT#; for example, 005#06# for six hours.
6.
Example of Complete Entry: 005#06#.
7.
Enter another # to indicate the end of programming.
8.
In this example, the lock will remain unlocked for six hours, starting from the time you put it in Passage Mode.
9.
You have now configured the duration of the Passage Mode period for that lock. This does NOT initiate Passage Mode.
10. The new length of time will take effect the next time you put a lock into Passage Mode by following the correct command sequence.
9
10
Procedure 5 - Program the Lock for Tamper Time
Parameters
You can set a Tamper Time Wrong Tries parameter referring to the number of times the wrong code can be entered before the lock goes into Tamper Shutdown Mode.
For example, if you program the lock to accept three wrong tries, the lock will tolerate three wrong entries, staying locked but providing visual feedback (see visual message chart in rear section). After that, it will go into a Tamper Shutdown Mode and remain locked until the end of the
Tamper Shutdown Time period - the length of that period is configured in
Steps 1a through 1 c below.
Required User Level: Master, Manager
1.
Set the tamper time for the period of time during which the keypad will remain inaccessible after the specified number of wrong Access Codes are entered a. Put the lock into Pushbutton Programming Mode.
b. Enter the code as follows - 006#TT# (TT is seconds - 00 to
90 seconds).
c. Example of Complete Entry: 006#30#. (for 30 seconds)
2. Enter the code as follows: 007 #TT# (TT is number of wrong entries - 03 to 09), let’s use 03 for example.
a. Example of Complete Entry: 007#03#.
b. Enter another # to indicate the end of programming.
c. The lock will stay locked after three wrong entries for the length of time you select in the steps below, even if a valid code (including the Master or a Manager Code) is entered after the three wrong codes. Only the mechanical key override will open the lock during the lockout period.
d.
Enter another # to indicate the end of programming.
In this example, the lock will now remain locked out for 30 seconds after three wrong Access Codes have been entered. No codes, even valid ones, will work in the lock until that time period has elapsed. During this tamper shut down period, the lock will flash the red LED once every 10 seconds
Procedure 6 - Programming the Lock for Keypad Buzzer
Volume
You might want to adjust the volume of the Keypad Buzzer depending on where the lock is located - a noisy or quiet area.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter the code 008#VV# (where VV is a scale of volume from
00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High).
3.
Example of Complete Entry: 008#02#.
4.
Enter another # to indicate the end of programming.
5.
The lock will now sound the buzzer at the desired volume
Normal, until you change it.
Users - General Information
1.
Master and Manager Codes can do two different things:
• Open the door by entering the Access Code without # signs.
• Put the lock into Pushbutton Programming Mode by entering
# before and after their Access Code.
2.
Each user (Manager User, Service User or Access User) occupies one of the available 100 locations in the user table.
3.
By default, user 000 is the Master User.
4.
Users have a 15-second period to enter the entire key sequence, and 5 seconds between pressing each pushbutton number. If they pause longer than 5 seconds between each pushbutton pressed, or exceed the 15-second period to enter the total sequence, the lock:
• aborts the current programming sequence
• automatically exits the programming state
• sends the user a ‘Keypad Timeout’ feedback message
11
12
Note: Correct errors during a command sequence. If an invalid entry occurs, recover from the mistake by entering the (*) key, which will clear all entries made from the beginning of the current command sequence, and will reset the 15-second time limit for entering the code.
In this case, you still have 15 seconds from the first number entered to enter the whole code.
User Levels
Four different classifications of users can perform various operations at the lock.
Master User - The Master User is the top-level manager who performs the initial lock setup activities and can program all lock functions. There is a maximum of one Master User per lock.
Manager - A Manager can program all lock functions except:
• defining the Access User Code length
• modifying master user Access Code
• resetting to default value
• activating lockout mode
• adding / deleting / enabling / disabling a Manager User. The number of Managers is limited only by available user table space (99 maximum because one (000) is reserved for the
Master Code).
Access User - An Access User has the ability to open the lock. The number of Access Users is limited only by available user table space (99 maximum because one (000) is reserved for the Master Code).
Service User - A user with an Access Code valid for a configurable period of time. This period of time starts on the first use of the code. Each Service
User combination is automatically deleted after its period of time expires.
The number of service users is limited only by available user table space
(99 maximum because one (000) is reserved for the Master Code).
Note: The total number of codes enrolled into the lock at any given time cannot exceed 100, regardless of code classification.
User Codes
Each time you add a user to give access to a door, you must program the door with an Access Code for them. This User Access Code can also be referred to as a PIN (Personal Identification Number). If you modify the
Access Code for an existing user, the procedure is the same.
User Codes must not have the exact same numbers in the same position as the Master Code.
The Master Code 00004992 is used as an example in the table below.
User Access Codes (PINs) - Examples
Master Code User Code Length
00004992
00004992
00004992
00004992
00004992
4 digits
5 digits
6 digits
7 digits
8 digits
Sample User Codes
Acceptable Unacceptable
1000
0005
1206
0001
32000
00006
00100
00044
001041
000046
400492
000048
0005521
2000499
9900872
1000892
80009765
12006654
00004993
40004992
0000
00004
000049
0000499
00004992
13
14
Procedure 1 Add/Modify a User Access Code
• When users no longer need access to the lock, delete the
User Code. This permits you to use the number for a new user.
• If you only de-activate the old code, you cannot add a user with the same number. De-activate should only be used when the User is, for example, on vacation, and his number will be re-activated when he returns.
• A User ID location is a 3-digit number assigned by the Master or Manager. You should have the list of User ID locations with you when programming locks. You should always maintain an accurate and correct list of User ID locations and users assigned to those ID locations. See the supplied sample form for your convenience on page 31.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter command 100# to add / modify a User Access Code.
3.
Enter the ID location followed by # - NNN#, we use 023# for example (Range = 000 to 099). The chart on page 30 may be helpful.
4.
Enter UUUUUUUU#, representing a User Access Code of between 4 and 8 numbers, depending on the length of Access
Code that you selected in Procedure 1 on page 7. For example, if your code length is 4 digits, the number could be 1024#.
5.
Enter the code 1024# again.
6.
Example of Complete Entry: 100#023#1024#1024#.
7.
Enter another # to indicate the end of programming.
8.
In this example, the User Access Code 1024 will now work in that door with all the access privileges assigned to that regular User.
Procedure 2 - Add/Modify a Manager Access Code
Each time you add a Manager access to a door, you must program the door with a Manager Access Code. If you change the Access Code for an existing Manager, the procedure is the same.
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter command 101# to add / modify a Manager
Access Code.
3.
Enter the User ID location (a three-digit number you have on a list that you should carry with you) followed by #, for example 024#.
4.
Enter UUUUUUUU#, representing a User Access Code of between 4 and 8 numbers, depending on the length of Access
Code that you selected in Procedure 1 on page 7. For example, if your code length is 4 digits, it could be 1224#.
5.
Enter the code 1224# again.
6.
Example of Complete Entry: 101#024#1224#1224#.
7.
Enter another # to indicate the end of programming.
8. The Manager Access Code 1224 will now work in that door with all the access privileges assigned to a Manager User.
9.
Manager Users can open the door by just entering the Access
Code without the # signs, or put the lock into Pushbutton
Programming Mode by entering # before and after their
Access Code.
Procedure 3 - Add/Modify Service User Access Code
A Service User is any person who needs access to the lock for a limited time period in order to perform a service, such as painting or repairs in the room or area. A Service User Access Code allows the service person to enter, exit and re-enter using that code for a certain number of hours.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 102# to add / modify a Service User Access Code.
3.
Enter the Service User ID location (a three-digit number you have on a list that you should carry with you) followed by #, for example 025#.
4.
Enter UUUUUUUU#, representing a User Access Code of between 4 and 8 numbers depending on the length of Access
Code that you selected in Procedure 1 on page 7. For example, if your code length is 4 digits, it could be 2240#.
5.
Enter the code 2240# again.
15
E-PLEX 2000 LIMITED WARRANTY
Kaba Access Control warrants the E-Plex 2000 to be free from defects in material and workmanship under normal use and service for a period of two (2) years from initial installation date. Kaba Access Control will repair or replace, at our discretion,
E-Plex 2000 Locks found by Kaba Access Control analysis to be defective during this period. Our only liability, whether in tort or in contract, under this warranty is to repair or replace products that are returned to
Kaba Access Control within the two (2) year warranty period.
This warranty is in lieu of and not in addition to any other warranty or condition, express or implied, including without limitation merchantability, fitness for purpose or absence of latent defects.
ATTENTION: This warranty does not cover problems arising out of improper installation, neglect or misuse. All warranties implied or written will be null and void if the lock is not installed properly and / or if any supplied component part is substituted with a foreign part. If the lock is used with a wall bumper, the warranty is null and void. If a doorstop is required, we recommend the use of a floor secured stop.
The environment and conditions of use determine the life of finishes on Kaba Access Control products. Finishes on Kaba Access Control products are subject to change due to wear and environmental corrosion. Kaba Access Control cannot be held responsible for the deterioration of finishes.
Authorization to Return Goods
Returned merchandise will not be accepted without prior approval.
Approvals and Returned Goods Authorization Numbers (RGA Numbers) for the E-Plex 2000 are available through our Customer Service department in Winston-Salem, NC (800) 849-8324. The serial number of a
lock is required to obtain this RGA Number. The issuance of an RGA does not imply that a credit or replacement will be issued.
The RGA number must be included on the address label when material is returned to the factory. All component parts including latches and strikes (even if not inoperative) must be included in the package with return. All merchandise must be returned prepaid and properly packaged to the address indicated.
6.
Now enter the number of hours, programmable between 01 and
24, for example 06. If you enter a Service Access Code of 00, you can only enter the door once. If the door shuts upon exiting, you will not be able to re-enter. This type of access is called a
“one-shot” code.
7.
Example of Complete Entry: 102#025#2240#2240#06#.
8.
Enter another # to indicate the end of programming.
9.
The Service User Access Code 2240 will now work in that door, with all the access privileges assigned to a Service User for a period of 6 hours from the time the Service User enters his Access Code.
Procedure 4 - Delete User Access Codes
User Access Codes should be deleted if no longer needed. This frees the numbers to be assigned to another user. Codes that may be needed some time in the future should be de-activated rather than deleted.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 200# to delete a User Access Code.
3.
Enter the ID location NNN#, where NNN is the specific User
ID location.
4.
Example of complete entry: 200 #023#.
5.
Enter another # to indicate the end of programming.
By deleting a User ID location, you have now also deleted a User Access
Code, allowing you to assign that number to another user if you wish.
Procedure 5 - Delete Manager Access Codes
A Manager Code should be deleted if no longer needed, in order to free the code number to be assigned to another Manager User. Manager
Codes that might be needed some time in the future should be deactivated rather than deleted.
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
19
20
2.
Enter Command 201# to delete a Manager Code.
3.
Enter the ID location NNN#, where NNN is the specific Manager
ID location, 024 for example.
4.
Example of complete entry: 201#024#.
5.
Enter another # to indicate the end of programming.
You have now deleted a Manager ID location, and (indirectly) his Access
Code, allowing you to assign that number to another Manager or Access
User if you wish.
Procedure 6 - Delete Service User Access Codes
A Service User Access Code is automatically deleted at the end of its specified length of time. However, use this procedure if you want to delete the code earlier than the specified expiry time.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 202# to delete Service User Access Code.
3.
Enter the ID location NNN #, where NNN is the specific Service
User ID location, 025 for example
4.
Example of complete entry: 202#025#.
5.
Enter another # to indicate the end of programming.
6.
You have now deleted a Service User ID location, and (indirectly) his access code, allowing you to assign that number to another
Service User if you wish.
Procedure 7 - Delete All Access Codes Except Master and Manager
All codes may be deleted together if you are changing everything because of, for example, suspected theft of codes. Warning - be sure that you want to do this, because re-creating codes for all the personnel will be time-consuming at the pushbuttons.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 299# to delete all Access and Service
User Codes.
3.
Enter another # to indicate the end of programming.
4.
You have now deleted all User Access Codes, allowing you to re-assign Access Codes from 0000{0000} to 9999{9999}, if not used by Master or Managers.
Procedure 8 - Activate User Access Codes
A User Code should be activated if it has been de-activated for a certain time period - during a user’s vacation, for example, or if you created an
Access Code but never assigned it to a user. User Codes that are inactive, but might be needed some time in the future, should be de-activated rather than deleted.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 300# to activate a User Code.
3.
Enter the ID location NNN #, where NNN is the specific User ID location, 023 for example.
4.
Example of complete entry: 300 #023#.
5.
Enter another # to indicate the end of programming.
6.
You have now activated the User Access Code assigned to 023.
Procedure 9 - Activate Manager Access Code
A Manager Code should be activated if it has been de-activated for a certain time period - during a Manager’s vacation, for example, or if you created a Manager’s Code, but never assigned it to anyone.
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 301# to activate a Manager Access Code.
3.
Enter the ID location NNN#, where NNN is the specific User ID location, 024 for example.
4.
Example of Complete Entry: 301#024#.
21
22
5.
Enter another # to indicate the end of programming.
6.
The Manager Access Code will now work in that door with all the access privileges assigned to a Manager User.
Procedure 10 - Activate Service User Access Code
A Service User Access Code should be activated if it has been deactivated for a certain time period - during a Service User’s vacation, for example, or if you created an Access Code but never assigned it to a
Service User.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 302# for Service User Functional Code.
3.
Enter the ID location NNN#, where NNN is the specific User ID location, 025 for example.
4.
Example of Complete Entry: 302#025#.
5.
Enter another # to indicate the end of programming.
6.
You have now activated a Service User Access Code.
Procedure 11 - Activate All User Access Codes
You may need to activate all users if you have de-activated the whole group - after a lockout, for example. This procedure will re-activate all regular and Service User Access Codes that are not active.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 398#.
3.
Example of Complete Entry: 398#.
4.
Enter another # to indicate the end of programming.
5.
You have now activated all regular User and Service User
Access Codes.
Procedure 12 - Activate/De-activate Passage Mode
You have already programmed a default duration for a door to remain in
Passage Mode. When you enable Passage Mode, it becomes enabled for the duration you have set in Procedure 5 - Program the Duration of the Passage Mode period, on page 9.
If your length is 6 hours, and you enable Passage Mode at 1:00, it will automatically re-lock at 7:00. Even if the lock was taken in and out of
Passage Mode multiple times during the six hour period, it will still re-lock after six hours (programmable) from the original starting period. This ensures that a lock will never remain in Passage Mode beyond the programmed time period.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 399# to activate / de-activate Passage Mode.
3.
Enter the code where 1 = activate Passage
Mode and 0 = de-activate Passage Mode.
4.
Example of Complete Entry to activate Passage Mode 399#1#.
5.
Enter another # to indicate the end of programming.
6.
You have now activated Passage Mode on the door.
Procedure 13 - De-activate User Access Codes
A User Code should be de-activated during a User’s vacation, for example, or if you created an Access Code but never assigned it to a User. User codes that are inactive, but might be needed some time in the future, should be de-activated rather than deleted.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 400# to de-activate User Access Codes.
3. Enter the code 400 #NNN #, where NNN is the specific User ID location, 023 for example.
4. Example of complete entry: 400 #023#.
6. You have now de-activated the User Access Code.
23
24
Procedure 14 - De-activate Manager Access Codes
A Manager Access Code should be de-activated for a certain time period
- during a Manager’s vacation, for example, or if you created an Access
Code but never assigned it to a Manager. Manager Codes that might be needed some time in the future should be de-activated rather than deleted.
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 401# to de-activate a Manager Access Code.
3.
Enter the code 401#NNN#, where NNN is the specific Manager
ID location, 024 for example.
4.
Example of complete entry: 401#024#.
5.
Enter another # to indicate the end of programming.
6.
You have now de-activated a Manager Access Code.
Procedure 15 - De-activate Service User Access Code
A Service User Access Code should be de-activated for a certain time period - during a Service User’s absence, for example, or if you created an Access Code but have not yet assigned it to a Service User. A
Service User’s time period continues to decrement if the User has only been de-activated, not deleted.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
3.
Enter the code 402#NNN#, where NNN is the specific Manager
ID location, 025 for example.
4. Example of Complete Entry: 402#025#.
6. You have now de-activated a Service User Access Code.
Procedure 16 - De-activate all Access Codes except
Master and Manager
You may need to de-activate all users, for example, during a plant shutdown. This procedure will de-activate all regular User Access Codes that are active, excluding Master and Manager Codes.
Required User Level: Master, Manager
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 498# to de-activate all Access and
Service Codes.
3.
Example of Complete Entry: 498#.
4.
Enter another # to indicate the end of programming.
5.
You have now de-activated all regular User Access Codes.
Procedure 17 - Activate/De-activate Lockout Mode
You may need to use Lockout Mode, for example, during a fire or fire drill when you do not want anyone to return to his or her office. This procedure will de-activate all regular User Access Codes that are active, including Manager Codes, but excluding the Master Code.
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 499# for Lockout Users Mode (except Master).
3.
Enter 1# to activate Lockout Mode and 0# to disable it.
4.
Example of Complete Entry: 499#1# or 499#0#.
5.
Enter another # to indicate the end of programming.
6.
You have now activated or de-activated Lockout Mode.
Procedure 18 - Perform Manual Diagnostics
Use the Diagnostic Code to perform manual diagnostics of the lock, green LED, red LED, buzzer, and the twelve pushbuttons - 0 through 9,
* and #.
25
26
Required User Level: Master
1.
Put the lock into Pushbutton Programming Mode.
2.
Enter Command 500# for Diagnostics.
3.
You will see a green LED and hear a high beep followed by a red LED and a low beep.
4.
Enter 123456789*0#, in that order exactly, to test each pushbutton. If every pushbutton is working correctly, you will see a green LED and hear a normal beep for each pushbutton that is pressed.
5.
Example of Complete Entry: 500#123456789*0#.
6.
Enter another # to indicate the end of programming.
7.
If you see a red LED at any time you are pressing a pushbutton, or at the end of the code, there could be a problem with the pushbuttons.
8.
Try the Diagnostic Code again, 500#123456789*0#, to be sure you entered all the numbers correctly and in the correct order.
9.
Enter another # to indicate the end of programming.
10. If you still see the red LED, the lock has a problem. Call a service person to repair or replace the lock.
Battery Life and Replacement
A variety of factors (shelf life, openings per day, environment, battery brand, lock settings, etc.) will determine how long your lock operates on a set of batteries. In average conditions, you can expect a minimum of 100,000 openings for E-Plex 2000 models with 3 “AA” Alkaline
Batteries.
A Low Battery condition is identified by a flash of both red and green
LEDs when a valid access code is entered and the lock will still give access. When the low battery condition is observed, the batteries should be replaced as soon as possible.
Summary of Pushbutton Programming Commands
Name
Configure
Command
000 #
Description of Command
‘Modify Master User Access Code (lock’s activation)’ (Always 8 digits)
Authorization
Master
MMMMMMMM#
MMMMMMMM#
004 # ‘Unlock time setup’ (TT = 02 to
20 seconds)
Master, Mgr
TT#
005 #
TT#
006 #
‘Passage Mode Timeout setup’ (TT = 01 to
24 hours - duration time in hours; 00 = no time limit)
Master, Mgr
‘Tamper time setup’ (TT = 00 to 90 seconds) Master, Mgr
TT#
007 #
TT#
008 #
VV#
009 #
LL#
099 #
‘Tamper wrong try setup’ (TT = 03 to 09) Master, Mgr
‘Buzzer volume control’ (VV = 00 to 03; 00
= off; 01 = Low; 02 = Normal; 03 = High)
Master, Mgr
‘Modify access length’ (LL = 04 to 08 digits) Master
‘Reset to factory default values’, except access code length. (Master, manager and access user are retained if already programmed. Users are not reset.)
Master
27
28
Summary of Pushbutton Programming Commands
Name
Add/Modify
Users
Command
100 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
101 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
102 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
HH#
Delete Users 200 #
NNN#
201 #
Description of Command
‘Add/Modify User Access Code’ NNN = specific User ID location (001 to 099)
(Combination length can be 4 to 8 digits, depending on access length LL setting)
‘Add/Modify Manager Access Code’ NNN = specific User ID location (001 to 099)
(Combination length can be 4 to 8 digits, depending on access length LL setting)
Master
‘Add/Modify Service User Access Code’ NNN
= specific User ID location (001 to 099) (HH
= 01 to 24 hours - duration time in hours; 00
= one-time entry; Combination length can be
4 to 8 digits, depending on access length LL setting)
Master, Mgr
‘Delete User Access Code’
‘Delete Manager Access Code’
Authorization
Master, Mgr
Master, Mgr
Master
NNN#
202 #
NNN#
299 #
‘Delete Service User Access Code’
‘Delete all User Access Codes’ (except
Master, and Manager User)
Master, Mgr
Master, Mgr
Summary of Pushbutton Programming Commands
Name
Activate
Users
Command
300 #
Description of Command
‘Activate User Access Code’
Authorization
Master, Mgr
NNN# NNN = specific User ID location (001 to 099)
301 #
NNN#
302 #
NNN#
398 #
‘Activate Manager Access Code’
NNN = specific User ID location (001 to 099)
Master
‘Activate Service User Access Code’
NNN = specific User ID location (001 to 099)
Master, Mgr
‘Activate all User Codes’ (except Master and Manager)
Master, Mgr
De-activate
Users
Diagnostic
399 #
P#
400 #
NNN#
401 #
NNN#
402 #
NNN#
498 #
499 #
L#
500 #
123456789*0#
‘Activate / De-Activate Passage Mode’
(P = 0 or 1; 0 = disable Passage Mode;
1 = enable Passage Mode)
Master, Mgr
‘De-Activate User Access Code’ Master, Mgr
NNN = specific User ID location (001 to 099)
‘De-Activate Manager Access Code’ Master
NNN = specific User ID location (001 to 099)
‘De-Activate Service User Access Code’ Master, Mgr
NNN = specific User ID location (001 to 099)
‘De-Activate all User Codes’ (except Master and Manager)
Master, Mgr
‘Activate / De-Activate Lockout Mode’
(Master User doesn’t affect by Lockout
Mode) (L = 0 or 1; 0 = disable Lockout
Mode; 1 = enable Lockout Mode)
‘Manual diagnostic’
Master
Master, Mgr
29
30
Visual Feedback Message Definitions
Condition Parameters
Valid pushbutton pressed
Timeout expired
Valid access code keyed
Access granted
Access granted
(battery low condition)
Access denied
Valid programming entry
Invalid programming entry (including duplicate access code)
Tamper shutdown beginning
Tamper shutdown state
Tamper shutdown ending
Green LED
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
ON
Red LED
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
Duration
1/10 sec
1 sec
1 sec
1/10 sec
1/10 sec
1 sec
1 sec
1 sec
2 sec
1 sec
2 sec
Rate
Once
Once
Once
1 sec
1 sec
Once
Once
Once
Once
10 sec
Once
009
010
011
012
013
002
003
004
005
006
007
008
014
015
016
017
E-Plex 2000 User List Table
User # Access Code User Name
001
099
User Type
31
advertisement
Key Features
- Multiple access modes for added convenience and security
- Audit trail capability for enhanced accountability
- Real-time monitoring and control for remote management
- Weather-resistant construction for outdoor use
- Easy installation and programming for quick setup
Frequently Answers and Questions
What is the default access code length?
What is the factory default unlock time?
What is the maximum number of user access codes that can be programmed?
Related manuals
advertisement
Table of contents
- 1 States of the Lock
- 1 Factory Mode
- 1 Access Mode
- 1 Pushbutton Programming Mode
- 1 Sequence of Operations for Start-Up Programming
- 2 Default Values of the E-Plex 2000 Programmable Parameters
- 3 Configuring the Lock
- 3 General Procedure for Pushbutton Programming
- 4 Reset Procedures
- 4 Procedure 1 - Program the Access Code Length
- 5 Procedure 2 - Modify the Master User Access Code
- 5 Procedure 3 - Program the Unlock Time
- 6 Procedure 4 - Program the Duration of the
- 7 Procedure 5 - Program the Lock for Tamper Time Parameters
- 8 Procedure 6 - Programming the Lock for Keypad
- 8 Users - General Information
- 9 User Levels
- 10 User Codes
- 10 User Access Codes (PINs) - Examples
- 11 Procedure 1 - Add / Modify a User Access Code
- 11 Procedure 2 - Add / Modify a Manager Access Code
- 12 Procedure 3 - Add / Modify Service User Access Code
- 16 Procedure 4 - Delete User Access Codes
- 16 Procedure 5 - Delete Manager Access Codes
- 11 Procedure 6 - Delete Service User Access Codes
- 11 Procedure 7 - Delete All Access Codes Except Master
- 11 Procedure 8 - Activate User Access Codes
- 11 Procedure 9 - Activate Manager Access Code
- 12 Procedure 10 - Activate Service User Access Code
- 12 Procedure 11 - Activate All User Access Codes
- 12 Procedure 12 - Activate / De-activate Passage Mode
- 12 Procedure 13 - De-activate User Access Codes
- 13 Procedure 14 - De-activate Manager Access Codes
- 13 Procedure 15 - De-activate Service User Access Code
- 13 Procedure 16 - De-activate all Access Codes except
- 13 Procedure 17 - Activate / De-activate Lockout Mode
- 13 Procedure 18 - Perform Manual Diagnostics