- No category
advertisement
Solar inverters
ABB string inverters
PVI-10.0/12.0-I-OUTD
10 to 12 kW
Designed for commercial usage, this three-phase inverter is highly unique in its ability to control the performance of the PV panels, especially during periods of variable weather conditions.
The high speed, precise Multiple Power
Point Tracker (MPPT) algorithm enables real-time power tracking and improved energy harvesting.
The input voltage range makes the inverter suitable for installations with reduced string size
Dual input section with independent
MPP tracking, allows for optimal energy harvesting from two sub-arrays oriented in different directions.
Each inverter is set on specific grid codes which can be selected in the field.
Highlights
− True three-phase bridge topology for
DC/AC output converter
− The HF isolation allows positive or negative ground configuration
− The unit is free of electrolytic capacitors, leading to a longer product lifetime
− Night wake up button to access energy harvesting data and error log
This device has two independent
MPPTs and efficiency ratings of up to
97.3%.
Flat efficiency curves ensure high efficiency at all output levels delivering consistent and stable performance across the entire input voltage and output power range.
The outdoor enclosure provides unrestricted usage under any environmental condition.
Additional highlights
− Integrated DC disconnect switch in compliance with international
Standards (-S version)
− Natural convection cooling for maximum reliability
− Outdoor enclosure for unrestricted use under any environmental conditions (IP65)
− RS-485 communication interface (for connection to laptop or data logger)
Technical data and types
Type code
Input side
Absolute maximum DC input voltage (V max,abs
)
Start-up DC input voltage (V start
)
Operating DC input voltage range (V dcmin
...V
dcmax
)
Rated DC input voltage (V dcr
)
Rated DC input power (P dcr
)
Number of independent MPPT
Maximum DC input power for each MPPT (P
MPPTmax
)
DC input voltage range with parallel configuration of
MPPT at P acr
DC power limitation with parallel configuration of MPPT
DC power limitation for each MPPT with independent configuration of MPPT at P acr
, max unbalance example
Maximum DC input current (I dcmax
) / for each MPPT
(I
MPPTmax
)
Maximum input short circuit current for each MPPT
Number of DC inputs pairs for each MPPT
DC connection type
Input protection
Reverse polarity protection
Input over voltage protection for each MPPT - varistor
Photovoltaic array isolation control
DC switch rating for each MPPT (version with DC switch)
Output side
AC grid connection type
Rated AC power (P acr
@cos φ=1 )
Maximum AC output power (P acmax
@cos φ=1)
Maximum apparent power (S max
)
Rated AC grid voltage (V ac,r
)
AC voltage range
Maximum AC output current (I ac,max
)
Contributory fault current
Rated output frequency (f r
)
Output frequency range (f min
...f
max
)
Nominal power factor and adjustable range
Total current harmonic distortion
AC connection type
Output protection
Anti-islanding protection
Maximum AC overcurrent protection
Output overvoltage protection - varistor
PVI-10.0-I-OUTD-400 PVI-12.0-I-OUTD-400
520 V
200 V (adj. 120...350 V)
0.7 x V start
...520 V
345 V
10500 W 12300 W
2 (5)
6800 W
220...470 V 250...470 V
Linear derating from max to null [470V ≤V
6800 W [285V ≤V
MPPT
≤470V]
the other channel: P dcr
[155V ≤V
MPPT
-6800W
≤470V]
MPPT
≤520V]
6800 W [275V
[220V ≤V
≤V
MPPT
≤470V] dcr
-6800W
MPPT
≤470V]
48.0 A / 24.0 A 50.0 A / 25.0 A
29.0 A
2
Tool Free PV connector WM / MC4
Yes, from limited current source
2
According to local standard
32 A / 600 V
Three phase 3W or 4W+PE
10000 W
11000 W (3)
11100 VA
12000 W
12500 W (4)
13300 VA
400 V
320...480 V (1)
16.0 A 18.0 A
25.0 A
50 Hz / 60 Hz
47...53 Hz / 57…63 Hz (2)
> 0.995, adj. ± 0.9 with P acr
=10.0 kW
< 2%
> 0.995, adj. ± 0.9 with P acr
=12.0 kW
Screw terminal block, cable gland M40
According to local standard
20.0 A
3 plus gas arrester
2 ABB Solar inverters | Product flyer for PVI-10.0/12.0-I-OUTD
Block diagram of PVI-10.0/12.0-I-OUTD
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
+
IN1
-
IN1.1(+)
IN1.2(+)
IN1.1(-)
IN1.2(-)
+ +
-
IN1 IN1
-
MPPT 1
(DC/DC)
HF transformer Bulk caps
Inverter
(DC/AC)
Line filter
Grid parallel relay
IN2.1(+)
IN1.2(+)
IN2.1(-)
IN2.2(-)
+
IN2
-
IN2.1(+)
IN2.2(+)
IN2.1(-)
IN2.2(-)
Standard version -S version
+
-
+
IN2 IN2
-
MPPT 2
(DC/DC)
HF transformer
DC/DC
DSP contr.
µP
DC/AC
DSP contr.
RS485
+ T/R
- T/R
RTN
Remote control
+ R
- R
Alarm
N.C
N.O
C
Control circuit
Technical data and types
Type code
Operating performance
Maximum efficiency ( η max
)
Weighted efficiency (EURO/CEC)
Feed in power threshold
Stand-by consumption
Communication
Wired local monitoring
Remote monitoring
Wireless local monitoring
User interface
Environmental
PVI-10.0-I-OUTD-400
97.3%
97.0% / -
30 W
< 8 W
PVI-12.0-I-OUTD-400
PVI-USB-RS232_485 (opt.)
VSN300 Wifi Logger Card (6) (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
VSN300 Wifi Logger Card (6) (opt.)
16 characters x 2 lines LCD display
Ambient temperature range
-25...+60°C /-13...140°F with derating above 50°C/122°F
0...100% condensing
< 50 dB(A) @ 1 m
2000 m / 6560 ft
IP 65
Natural
716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”
< 45.8 kg / 99.0 lb
Wall bracket
-25...+60°C /-13...140°F with derating above 45°C/113°F
Relative humidity
Noise emission
Maximum operating altitude without derating
Physical
Environmental protection rating
Cooling
Dimension (H x W x D)
Weight
Mounting system
Safety
Isolation level
Marking
Safety and EMC standard
Grid standard (check your sales channel for availability)
HF transformer
CE (50 Hz only)
EN 50178, EN62109-1, EN62109-2,
AS/NZS3100, AS/NZS 60950, EN61000-3-2,
EN61000-3-3, EN61000-6-2, EN61000-6-3
CEI 0-21, CEI 0-16, VDE 0126-1-1,
VDE-AR-N 4105, G83/2, G59/3, C10/11,
EN 50438 (not for all national appendices),
RD1699, RD 1565, AS 4777, ABNT NBR
16149, CLC/FprTS 50549
EN 50178, EN62109-1, EN62109-2,
AS/NZS3100, AS/NZS 60950, EN61000-6-2,
EN61000-6-3, EN61000-3-11, EN61000-3-12
CEI 0-21, CEI 0-16, VDE 0126-1-1, VDE-AR-N
4105, G59/3, C10/11, EN 50438 (not for all national appendices), RD1699, RD 1565, AS
4777, ABNT NBR 16149, CLC/FprTS 50549
Available products variants
Standard
With DC switch
PVI-10.0-I-OUTD-400
PVI-10.0-I-OUTD-S-400
1. The AC voltage range may vary depending on specific country grid standard
2. The Frequency range may vary depending on specific country grid standard
4. Limited to 12000 W for Germany
5. Independent MPPT just with negative ground
3. Limited to 10000 W for Belgium and Germany 6. Check availability before to order
Remark. Features not specifically listed in the present data sheet are not included in the product
PVI-12.0-I-OUTD-400
PVI-12.0-I-OUTD-S-400
Product flyer for PVI-10.0/12.0-I-OUTD | ABB Solar inverters 3
L1
L2
L3
N
PE
Efficiency curves of PVI-10.0-I-OUTD
98
97
100
99
96
95
94
93
92
91
90
0% 10% 20% 30% 40% 50% 60%
% of Rated Output Power
70% 80%
220 Vdc
345 Vdc
416 Vdc
90% 100%
Efficiency curves of PVI-12.0-I-OUTD
98
97
96
95
100
99
94
93
92
91
90
0% 10% 20% 30% 40% 50% 60%
% of Rated Output Power
70% 80%
250 Vdc
345 Vdc
416 Vdc
90% 100%
Support and service
ABB supports its customers with dedicated, global service organization in more than 60 countries and strong regional and national technical partner networks providing complete range of life cycle services.
For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com
© Copyright 2014 ABB. All rights reserved.
Specifications subject to change without notice.
advertisement