- Industrial & lab equipment
- Electrical equipment & supplies
- TR-Electronic
- V4 USB PC-Adapter V4
- Installation Guide
- 32 Pages
TR-Electronic V4 USB PC-Adapter V4, USB PC-Adapter USB PC adapter, PT-6, PT-6N, PT-15/2 Switch cabinet module Installation Guide
Below you will find brief information for USB PC adapter V4 USB PC-Adapter V4, Switch cabinet module PT-6, Switch cabinet module PT-6N, Switch cabinet module PT-15/2. The USB PC adapter V4 is designed for communication between a PC with a USB interface and TR devices with an RS485 interface. It is compatible with TRWinProg, EPROGW32, and LTProg software. The adapter can be used with different switch cabinet modules, including PT-6, PT-6N, and PT-15/2, which are connected via a 15-pin D-SUB connector. This guide will provide instructions on installing the USB driver, programming the adapter, and connecting it to your devices.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Installationsanleitung
Installation Guide
USB PC-Adapter V4
Art-No.: 490-00310
Seite 2-16
Page 17-32
•
TRWinProg
•
EPROGW32
•
LTProg
Programmable PC-Adapter
USB <---> RS485
PC-Adapter mit PC adapter with
● USB-Kabel
● Flachband-Kabel
● Steckernetzteil
● Gerätetreiber
● USB cable
● Flat Ribbon Cable
● Power Supply Unit
● Device Driver
TR-Electronic GmbH
D-78647 Trossingen
Eglishalde 6
Tel.: (0049) 07425/228-0
Fax: (0049) 07425/228-33
E-mail: [email protected]
http://www.tr-electronic.de
Urheberrechtsschutz
Dieses Handbuch, einschließlich den darin enthaltenen Abbildungen, ist urheberrechtlich geschützt. Drittanwendungen dieses Handbuchs, welche von den urheberrechtlichen Bestimmungen abweichen, sind verboten. Die Reproduktion,
Übersetzung sowie die elektronische und fotografische Archivierung und Veränderung bedarf der schriftlichen Genehmigung durch den Hersteller. Zuwiderhandlungen verpflichten zu Schadenersatz.
Änderungsvorbehalt
Jegliche Änderungen, die dem technischen Fortschritt dienen, vorbehalten.
Dokumenteninformation
Ausgabe-/Rev.-Datum:
Dokument-/Rev.-Nr.:
Dateiname:
Verfasser:
03/14/2012
TR - E - TI - DGB - 0074 - 03
TR-E-TI-DGB-0074-02.DOC
MÜJ
Schreibweisen
Kursive oder fette Schreibweise steht für den Titel eines Dokuments oder wird zur
Hervorhebung benutzt.
Courier-Schrift zeigt Text an, der auf dem Display bzw. Bildschirm sichtbar ist und
Menüauswahlen von Software.
< > weist auf Tasten der Tastatur Ihres Computers hin
(wie etwa <RETURN>).
Marken
Genannte Produkte, Namen und Logos dienen ausschließlich Informationszwecken und können eingetragene Warenzeichen ihrer jeweiligen Eigentümer sein, ohne dass eine besondere Kennzeichnung erfolgt.
TR-Electronic GmbH 2007, All Rights Reserved
Page 2 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Änderungs-Index
Änderung Datum Index
Erstausgabe
EPROG-Version V1.0.1.4 --> V1.0.3.4
13.06.07 00
22.06.07 01
Erkennung des PC-Adapters nur dann, wenn kein Steckernetzteil und kein Mess-
System angeschlossen ist
03.02.12 02
Windows 7 32bit/64bit 14.03.12 03
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 3 of 32
Inhaltsverzeichnis
TR-Electronic GmbH 2007, All Rights Reserved
Page 4 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Allgemeines
1 Allgemeines
Der USB PC-Adapter V4 wird zur Kommunikation zwischen PC – USB-Schnittstelle und
TR-Geräten mit RS485-Schnittstelle benötigt. Die Programmierung des programmspezifischen Protokolls erfolgt durch die Programmiersoftware „TRWinProg“.
Unterstützt wird der PC-Adapter durch folgende PC-Programme:
● TRWinProg ab V3.42, Soft-Nr.: 490-00416
● EPROGW32 ab V1.0.3.4,
● LTProg,
Soft-Nr.: 490-00418
Soft-Nr.: 490-00415
Bei der Installation der USB-Treiber wird zunächst ein USB-Modul Treiber und anschließend ein USB Serial Port Treiber installiert. Der COM-Port wird dabei als virtuelle Schnittstelle angelegt. Der PC-Adapter wird PC-intern daher wie eine normale
COM-Schnittstelle genutzt.
Systemanforderungen
IBM kompatibler PC
DVD-ROM Laufwerk
Eine verfügbare USB-Schnittstelle
Windows 98SE
®
/Me
®
oder Windows NT 4
®
/ 2000
®
/ XP
®
/ 7
®
32bit / 7
®
64bit
2 Symbol- und Hinweis-Definition
bezeichnet wichtige Informationen bzw. Merkmale und Anwendungstipps des verwendeten Produkts.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 5 of 32
Lieferumfang
3 Lieferumfang
● Kunststoff-Koffer, mit nachfolgenden Komponenten:
– USB PC-Adapter V4
Umsetzung USB <--> RS485
– USB-Kabel 1,00 m
Verbindungskabel zwischen
PC-Adapter und PC
– Flachbandkabel 1,30 m
Verbindungskabel zwischen
PC-Adapter und TR-Schaltschrank-Modul
(15-pol. SUB-D Buchse/Stecker)
– Steckernetzteil 24 V DC, 1A
Versorgungsmöglichkeit des angeschlossenen Gerätes über den PC-Adapter
– Software- und Support-DVD
- USB-Treiber, Soft-Nr.: 490-00421
- TRWinProg, Soft-Nr.: 490-00416
- EPROGW32, Soft-Nr.: 490-00418
- LTProg, Soft-Nr.: 490-00415
– Installationsanleitung
TR-E-TI-DGB-0074, Deutsch/Englisch
TR-Electronic GmbH 2007, All Rights Reserved
Page 6 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Hardware-Beschreibung
4 Hardware-Beschreibung
4.1 Steckerbelegung, 15-pol. SUB-D
15-pol. SUB-D Stecker
Pin
1
2
3 – 6
Signal
RS-485 –
RS-485 +
N.C.
7 intern gebrückt auf Pin 14 (PT Schaltausgang für TA-Mini)
8 – 13 N.C.
14 Versorgungsspannung_OUT, 24 V DC
Versorgungsspannung_OUT, 0V wenn Steckernetzteil am PC-
Adapter angeschlossen ist
4.2 Status-LEDs
15 ext. power rxd - pc txd - pc no device
● LED ext. power: leuchtet grün, wenn das Steckernetzteil am +24 Vdc-Eingang des PC-Adapters angeschlossen ist.
Ein am PC-Adapter angeschlossenes Mess-System kann über den 15-pol. SUB-D
Stecker versorgt werden. Besteht eine Verbindung mit
- TRWinProg,
- EPROGW32 oder
- LTProg, wird im Online-Betrieb das angeschlossene Mess-System erkannt. Programmierungen beziehen sich auf das Mess-System.
● LED rxd - pc: leuchtet gelb, wenn Daten empfangen werden
● LED txd - pc: leuchtet gelb, wenn Daten gesendet werden
● LED no device: leuchtet rot, wenn das Steckernetzteil nicht am +24 Vdc-Eingang des PC-Adapters angeschlossen ist. Ein am PC-Adapter angeschlossenes Mess-System muss separat versorgt werden.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 7 of 32
Hardware-Beschreibung
4.3 Umschaltung der Geräte-Versorgung
● Steckernetzteil nicht am PC-Adapter angeschlossen
- Das Mess-System muss separat mit Spannung versorgt werden.
● Steckernetzteil am PC-Adapter angeschlossen
- Das Mess-System wird über den PC-Adapter mit Spannung versorgt.
4.4 Abmessungen
TR-Electronic GmbH 2007, All Rights Reserved
Page 8 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Installation der USB-Treiber
5 Installation der USB-Treiber
Zur Installation werden zunächst die entsprechenden Treiber-Dateien benötigt. Hierzu gibt es zwei Möglichkeiten:
1. Die Treiber-Dateien befinden sich auf der Software- und Support-DVD unter der
Ordnerstruktur „Deutsch --> Download nach Soft-Nr. --> 490-00421“.
Von dort aus können die Treiber-Dateien lokal auf die Festplatte kopiert werden und extrahiert werden.
2. Wenn das Programm TRWinProg bereits installiert ist, befinden sich die Treiber-
Dateien schon auf der Festplatte im Verzeichnis
„...\TRWinProg\USBDriver“
Im Verlauf der Installation muss dann der entsprechende Ablageort der Treiber-Dateien angegeben werden.
Zunächst wird der PC-Adapter über das USB-Kabel mit dem PC verbunden, der PC muss sich hierzu im Betrieb befinden. Type A wird in den PC eingesteckt und Type B in den PC-Adapter.
Type A
Type B
Nach Herstellung der Verbindung wird automatisch der Assistent für das Suchen
neuer Hardware gestartet.
Als Beispiel werden im Folgenden die Installationsschritte unter WINDOWS
®
XP aufgezeigt.
Erscheint im Begrüßungsfenster die Meldung Soll eine Verbindung mit
Windows Update hergestellt werden, um nach Software zu suchen?, ist der Radio Button Nein, diesmal nicht zu aktivieren. Klicken Sie danach auf
Weiter.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 9 of 32
Installation der USB-Treiber
Markieren Sie den Eintrag "Software von einer Liste oder bestimmten
Quelle installieren ..." und klicken Sie auf Weiter.
Markieren Sie den Eintrag "Folgende Quelle ebenfalls durchsuchen:".
Klicken Sie den Button Durchsuchen und wählen Sie den Ablageort der Treiber-
Dateien aus. Hier als Beispiel C:\Programme\TRWinProg\USBDriver.
Klicken Sie anschließend auf Weiter.
TR-Electronic GmbH 2007, All Rights Reserved
Page 10 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Installation der USB-Treiber
Warnmeldung ignorieren und "Installation fortsetzen" klicken
Installation fertig stellen
Danach wird der Assistent für das Suchen neuer Hardware für den
Serial Port erneut gestartet. Die Vorgehensweise ist die gleiche wie zuvor. Nach
Abschluss der Installation ist der PC-Adapter funktionsfähig.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 11 of 32
Installation der USB-Treiber
Wurden die Treiber ordnungsgemäß installiert, werden im "Geräte-Manager" zwei neue Einträge angezeigt:
Die automatisch zugewiesene COM-Port Nummer kann mit Klick (rechte Maustaste) auf den Eintrag auch geändert werden:
TR-Electronic GmbH 2007, All Rights Reserved
Page 12 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Programmierung
6 Programmierung
6.1 Default-Einstellungen
Bei Auslieferung sind folgende Parameter voreingestellt:
● Richtungssteuerung: Protokoll-typisch (durch Adapter)
● Protokoll-Typ: TRWinProg
● Baudrate: 9600 Baud
Wenn der PC-Adapter unter TRWinProg eingesetzt werden soll, muss keine
Programmierung des PC-Adapters vorgenommen werden.
Für den Einsatz unter
● EPROGW32 oder
● LTProg muss der Protokoll-Typ und eventuell die Baudrate angepasst werden. Im Folgenden werden die Programmiermöglichkeiten unter TRWinProg aufgezeigt.
6.2 Voraussetzungen
Der PC-Adapter lässt sich nur über die Programmiersoftware TRWinProg programmieren. Zur Programmierung muss TRWinProg deshalb bereits auf dem PC installiert sein. Ist dies nicht der Fall, können das Programm und die Programm-
Dokumentation von der Software- und Support-DVD downgeloadet werden:
„Deutsch --> Download nach Soft-Nr. --> 490-00416“
Damit der PC-Adapter durch TRWinProg erkannt wird, dürfen kein Steckernetzteil
und kein Mess-System am PC-Adapter angeschlossen sein. Es darf lediglich eine
Verbindung über das USB-Kabel zum PC hergestellt werden!
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 13 of 32
Programmierung
6.3 Grundparameter
6.3.1 Ric
h
tungs-Steuerung
Auswahl
Original
(durch PC)
Protokoll-typisch
(durch Adapter)
Beschreibung
Die Richtungssteuerung der RS485-Schnittstelle wird durch die Steuersignale der seriellen PC-Schnittstelle vorgenommen. Das eingestellte Protokoll unter
Protokoll-Typ wird dabei ignoriert. Der Protokoll-
Typ wird im Online-Betrieb automatisch durch die aktive
Programmiersoftware
● TRWinProg
● EPROGW32 oder
● LTProg erkannt. Bedingt durch die PC-Hardware können
Timing-Probleme auftreten. Dieser Betrieb ist daher nicht zu empfehlen.
Die Richtungssteuerung der RS485-Schnittstelle wird durch den PC-Adapter selbst vorgenommen. Jedoch muss, der Programmiersoftware entsprechend, der richtige Protokoll-Typ eingestellt werden. Bei einer falschen Einstellung kann im Online-Betrieb keine
Verbindung aufgebaut werden.
Default
X
6.3.2 Protokoll-Typ
Auswahl
TRWinProg
EPROG
LTProg
Beschreibung
Wurde unter Richtungs-Steuerung die Auswahl
Protokoll-typisch ausgewählt, wird der PC-
Adapter mit dieser Einstellung auf die TRWinProg-
Kommunikation voreingestellt. Das zu programmierende Mess-System muss TRWinProg-kompatibel sein.
Wurde unter Richtungs-Steuerung die Auswahl
Protokoll-typisch ausgewählt, wird der PC-
Adapter mit dieser Einstellung auf die EPROG-Kommunikation voreingestellt. Das zu programmierende
Mess-System muss EPROG-kompatibel sein.
Wurde unter Richtungs-Steuerung die Auswahl
Protokoll-typisch ausgewählt, wird der PC-
Adapter mit dieser Einstellung auf die LTProg-Kommunikation voreingestellt. Das zu programmierende Mess-
System muss LTProg-kompatibel sein.
Default
X
Mithoer-Betrieb
(nur Empfang)
Für interne Protokollierungen
TR-Electronic GmbH 2007, All Rights Reserved
Page 14 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
6.3.3 Baudrate
Auswahl
9600 Baud
Programmierung
Beschreibung
Übertragungsgeschwindigkeit PC-Adapter <--> PC
9600 Bit/s
19200 Baud
Übertragungsgeschwindigkeit PC-Adapter <--> PC
19200 Bit/s
Default
X
38400 Baud
57600 Baud
Übertragungsgeschwindigkeit PC-Adapter <--> PC
38400 Bit/s
Übertragungsgeschwindigkeit PC-Adapter <--> PC
57600 Bit/s
115200 Baud
Übertragungsgeschwindigkeit PC-Adapter <--> PC
115200 Bit/s
Beim Übertragen der Daten an den PC-Adapter wird überprüft, ob die eingestellte
Baudrate durch den ausgewählten Protokoll-Typ auch unterstützt wird. Konflikte werden über eine entsprechende Fehlermeldung angezeigt.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 15 of 32
Geräte-Anbindung
7 Geräte-Anbindung
Zur Geräte-Anbindung stehen unterschiedliche Schaltschrankmodule zur Verfügung. Die
15-pol. SUB-D Buchse dient für den Anschluss des PC-Adapters.
Bestell-Nr.: Beschreibung
490-00101
PT-6
Standard Schaltschrankmodul mit 6
Schraubklemmen.
490-00107
PT-6N
Schaltschrankmodul mit 6 Schraubklemmen und Leitungsabschluss der
Programmiersignale.
490-00105
PT-15/2
Schaltschrankmodul mit 2 x 16-pol.
Klemmblöcken
Anschluss-Schema mit Steckernetzteil
Anschluss-Schema ohne Steckernetzteil
TR-Electronic GmbH 2007, All Rights Reserved
Page 16 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Manual
USB PC adapter V4
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 17 of 32
TR-Electronic GmbH
D-78647 Trossingen
Eglishalde 6
Tel.: (0049) 07425/228-0
Fax: (0049) 07425/228-33
E-mail: [email protected]
http://www.tr-electronic.de
Copyright protection
This Manual, including the illustrations contained therein, is subject to copyright protection. Use of this Manual by third parties in contravention of copyright regulations is forbidden. Reproduction, translation as well as electronic and photographic archiving and modification require the written content of the manufacturer. Offenders will be liable for damages.
Subject to amendments
Any technical changes that serve the purpose of technical progress, reserved.
Document information
Release date/Rev. date:
Document rev. no.:
File name:
Author:
03/14/2012
TR - E - TI - DGB - 0074 - 03
TR-E-TI-DGB-0074-02.DOC
MÜJ
Font styles
Italic or bold font styles are used for the title of a document or are used for highlighting.
Courier font displays text, which is visible on the display or screen and software menu selections .
< > indicates keys on your computer keyboard (such as <RETURN>).
Trademarks
Named Products, Names and Logos exclusively serve for information purposes and can be registered trade marks of their respective owners, without a special marking within the document.
TR-Electronic GmbH 2007, All Rights Reserved
Page 18 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Revision index
Revision Date Index
First release
EPROG version V1.0.1.4 --> V1.0.3.4
06/13/07 00
06/22/07 01
Detection of the PC adapter only possible, if no Plug Power Supply Unit and no measuring system are connected
02/03/12 02
03/14/12 03 Windows 7 32bit/64bit
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 19 of 32
Contents
TR-Electronic GmbH 2007, All Rights Reserved
Page 20 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
General
1 General
The USB PC adapter V4 is used for communication between PC – USB interface and
TR-devices with RS485 interface. The programming of the program-specific protocol occurs with the programming software “TRWinProg”.
The PC adapter is supported by the following PC programs:
● TRWinProg V3.42 or later, Soft-No.: 490-00416
● EPROGW32 V1.0.3.4 or later,
● LTProg,
Soft-No.: 490-00418
Soft-No.: 490-00415
At the installation first an USB-Modul driver and then an USB Serial Port driver will be installed. The COM Port is created thereby as a virtual interface. The PC adapter is used
PC-internally therefore like a normal COM interface.
System Requirements
IBM compatible PC
DVD-ROM Drive
One available USB interface
Windows 98SE
®
/Me
®
or Windows NT 4
®
/ 2000
®
/ XP
®
/ 7
®
32bit / 7
®
64bit
2 Definition of symbols and instructions
indicates important information’s or features and application tips for the product used.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 21 of 32
Package contents
3 Package contents
● Plastic case, with the following components:
– USB PC adapter V4
Conversion USB <--> RS485
– USB cable 1.00 m
Connection cable between
PC adapter and PC
– Flat ribbon cable 1.30 m
Connection cable between
PC adapter and TR switch cabinet module
(15-pol. SUB-D female/male)
– Plug Power Supply Unit 24 V DC, 1A
The connected device can be supplied via the PC adapter
– Software- and Support-DVD
- USB driver, Soft-No.: 490-00421
- TRWinProg, Soft-No.: 490-00416
- EPROGW32, Soft-No.: 490-00418
- LTProg, Soft-No.: 490-00415
– Installation Guide
TR-E-TI-DGB-0074, German/English
TR-Electronic GmbH 2007, All Rights Reserved
Page 22 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Hardware description
4 Hardware description
4.1 Pin assignment, 15-pol. D-SUB
15-pol. D-SUB male connector
Pin
1
2
3 – 6
Signal
RS-485 –
RS-485 +
N.C.
7 internal connected to pin 14 (PT switching output for TA-Mini)
8 – 13 N.C.
14 Supply voltage_OUT, 24 V DC
Supply voltage_OUT, 0V if Plug Power Supply Unit is connected to the PC adapter
4.2 Status LEDs
15 ext. power rxd - pc txd - pc no device
● LED ext. power: lights up green, if the Plug Power Supply Unit is connected at the +24 Vdc input of the PC adapter. A measuring system which is connected to the PC adapter can be supplied over the
15-pol. D-SUB connector. If a connection with
- TRWinProg,
- EPROGW32 or
- LTProg, exists, in online operation the connected measuring system is detected.
Programming’s refer to the measuring system.
● LED rxd - pc: lights up yellow, if data are received
● LED txd - pc: lights up yellow, if data are sent
● LED no device: lights up red, if the Plug Power Supply Unit is not connected at the +24 Vdc input of the PC adapter. A measuring system which is connected to the PC adapter must be supplied separately.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 23 of 32
Hardware description
4.3 Switch-over the device-supply
● Plug Power Supply Unit not connected to the PC adapter
- The measuring system must be supplied separately with voltage.
● Plug Power Supply Unit connected to the PC adapter
- The measuring system is supplied via the PC adapter with voltage.
4.4 Dimensions
TR-Electronic GmbH 2007, All Rights Reserved
Page 24 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Installation of the USB driver
5 Installation of the USB driver
For the installation first the appropriate driver files are used. For this there are two alternatives:
1. The driver files are on the Software- and Support-DVD under the folder structure
„English --> Download according to Soft-No. --> 490-00421“.
From there the driver files can be copied and extracted locally on the hard disk.
2. If the program TRWinProg is already installed, the driver files are already on the hard disk in the directory “...\TRWinProg\USBDriver”
In the process of the installation then the appropriate file location of the driver files must be indicated.
First the PC adapter is to be connected about the USB cable with the PC, for this the PC must be in operation. Type A is connected into the PC and Type B into the PC adapter.
Type A
Type B
After establishing of the connection the Found New Hardware Wizard is started automatically.
As example in the following the installation steps under WINDOWS
®
XP are presented.
If the message appears Shall be established a connection with Windows-
update, in order to search for software? in the Welcome window, the
Radio Button No, not this time is to be activated. Click Next to continue.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 25 of 32
Installation of the USB driver
Select "Install from a list or specific location (Advanced)" and click Next to continue.
Select "Include this location in the search:".
Click the Browse Button and select the location of the driver files.
For example C:\Program\TRWinProg\USBDriver.
Click Next to continue.
TR-Electronic GmbH 2007, All Rights Reserved
Page 26 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Installation of the USB driver
Ignore the warning message and click"Continue Anyway"
Completion of the Installation
After this the Found New Hardware Wizard is started again for the Serial Port. The proceeding is the same as before. After finishing of the installation the PC adapter is functional.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 27 of 32
Installation of the USB driver
If the USB-drivers were installed correctly, two new entries are displayed in the
"Device Manager":
About the context menu (Right-click onto the entry) --> Properties, the Port number also can be changed:
TR-Electronic GmbH 2007, All Rights Reserved
Page 28 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
Programming
6 Programming
6.1 Default settings
In case of delivery the following parameters are preset:
● Direction-Controlling: Protocol typically (Adapter controlled)
● Protocol-Type: TRWinProg
● Baud rate: 9600 Baud
If the PC adapter shall be operated under TRWinProg, no programming of the PC adapter is necessary.
For the operation under
● EPROGW32 or
● LTProg the protocol type and possibly the baud rate must be adjusted. In the following the programming possibilities under TRWinProg are presented.
6.2 Requirements
The PC adapter can be programmed only about the programming software TRWinProg.
Therefore, TRWinProg must already be installed on the PC for programming. If this is not the case, the program and the program documentation can be downloaded from the
Software- and Support-DVD:
„English --> Download according to Soft-No. --> 490-00416“
So that the PC adapter is detected by TRWinProg, no Plug Power Supply Unit and
no measuring system at the PC adapter must be connected. Only a connection about the USB-cable to the PC must be established!
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 29 of 32
Programming
6.3 Basic parameter
6.3.1 Direction-Controlling
Selection
Original
(PC-controlled)
Protocol-typically
(Adapter-controlled)
Description
The direction controlling of the RS485 interface is performed by the control signals of the serial PC interface. In this connection, the adjusted protocol under Protocol-Type is ignored. In the online operation the type of protocol is recognized automatically by the active programming software
● TRWinProg
● EPROGW32 or
● LTProg
Due to the PC hardware timing problems can occur.
Therefore this operation is not recommended.
The direction controlling of the RS485 interface is performed by the PC adapter. However, according to the programming software the correct protocol type must be adjusted. If the setting is not correct, no connection can be established in the online operation.
Default
X
6.3.2 Protocol-Type
Selection
TRWinProg
EPROG
LTProg
Description
If the selection Protocol-typically was selected in the section Direction-Controlling, with this setting the PC adapter is preset to TRWinProgcommunication. The measuring system, which is to be programmed, must be TRWinProg-compatible.
If the selection Protocol-typically was selected in the section Direction-Controlling, with this setting the PC adapter is preset to EPROGcommunication. The measuring system, which is to be programmed, must be EPROG-compatible.
If the selection Protocol-typically was selected in the section Direction-Controlling, with this setting the PC adapter is preset to LTProgcommunication. The measuring system, which is to be programmed, must be LTprog-compatible.
Default
X
Listen-Mode
(receiving only)
For internal loggings
TR-Electronic GmbH 2007, All Rights Reserved
Page 30 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
6.3.3 Baud rate
Selection
9600 Baud
Description
Transfer rate PC adapter <--> PC: 9600 bit/s
Programming
Default
X
19200 Baud Transfer rate PC adapter <--> PC: 19200 bit/s
38400 Baud Transfer rate PC adapter <--> PC: 38400 bit/s
57600 Baud Transfer rate PC adapter <--> PC: 57600 bit/s
115200 Baud Transfer rate PC adapter <--> PC: 115200 bit/s
When transferring the data to the PC adapter, it is checked, whether the adjusted baud rate is also supported by the selected Protocol-Type.
Printed in the Federal Republic of Germany
03/14/2012 TR - E - TI - DGB - 0074 - 03
TR-Electronic GmbH 2007, All Rights Reserved
Page 31 of 32
Device connection
7 Device connection
For device connection different switch cabinet modules are available. The 15-pol. D-SUB female connector serves for the connection of the PC adapter.
Order-No.: Description
490-00101
PT-6
Standard switch cabinet module with 6 screw terminals.
490-00107
PT-6N
Switch cabinet module with 6 screw terminals and line termination of the programming signals.
490-00105
PT-15/2
Switch cabinet module with 2 x 16-pol. terminal blocks
Connection schematic with Plug Power Supply Unit
Connection schematic without Plug Power Supply Unit
TR-Electronic GmbH 2007, All Rights Reserved
Page 32 of 32 TR - E - TI - DGB - 0074 - 03
Printed in the Federal Republic of Germany
03/14/2012
advertisement
Key Features
- Communication between PC and TR devices
- USB to RS485 conversion
- Support for TRWinProg, EPROGW32, and LTProg software
- Use with various switch cabinet modules
- Driver installation and programming instructions
Frequently Answers and Questions
What is the purpose of the USB PC adapter V4?
How do I install the USB driver?
Is the PC adapter compatible with EPROGW32, LTProg and TRWinProg?
How do I connect the USB PC adapter V4 to my device?
Related manuals
advertisement
Table of contents
- 5 1 Allgemeines
- 5 2 Symbol- und Hinweis-Definition
- 6 3 Lieferumfang
- 7 4 Hardware-Beschreibung
- 7 4.1 Steckerbelegung, 15-pol. SUB-D
- 7 4.2 Status-LEDs
- 8 4.3 Umschaltung der Geräte-Versorgung
- 8 4.4 Abmessungen
- 9 5 Installation der USB-Treiber
- 13 6 Programmierung
- 13 6.1 Default-Einstellungen
- 13 6.2 Voraussetzungen
- 14 6.3 Grundparameter
- 14 6.3.1 Richtungs-Steuerung
- 14 6.3.2 Protokoll-Typ
- 15 6.3.3 Baudrate
- 16 7 Geräte-Anbindung
- 21 1 General
- 21 2 Definition of symbols and instructions
- 22 3 Package contents
- 23 4 Hardware description
- 23 4.1 Pin assignment, 15-pol. D-SUB
- 23 4.2 Status LEDs
- 24 4.3 Switch-over the device-supply
- 24 4.4 Dimensions
- 25 5 Installation of the USB driver
- 29 6 Programming
- 29 6.1 Default settings
- 29 6.2 Requirements
- 30 6.3 Basic parameter
- 30 6.3.1 Direction-Controlling
- 30 6.3.2 Protocol-Type
- 31 6.3.3 Baud rate
- 32 7 Device connection