Watts Z-Series Basic, Pump, Pump Mix Hydronex Z-Series Panel Instruction Manual
Hydronex Z-Series Basic, Z-Series Pump and Z-Series Pump Mix are part of a zone-specific distribution panels line. It is a distribution panel that includes stainless steel manifolds to distribute water to radiant circuits, baseboard or other single temperature hydronic equipment.These panels are supplied with or without zone pumps, water temperature mixing, and zone actuators.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
For Residential and Light Commercial Applications
05-349-1139-30-06
Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––
HydroNex Z-Series Panel
Sizes:
1-1/4" Trunk; 1" Stainless Steel Manifold
Z Series panels are zone specifi c distribution panels.
These panels include stainless steel manifolds to distribute water to radiant circuits, baseboard or other single temperature hydronic equipment. Z Panels are supplied with or without zone pumps, water temperature mixing, and zone actuators.
All Z Series panels come pre-installed in a wall enclosure with lockable access cover. Z Series panels are available in 2-12 circuit confi gurations.
Installation
Make sure an electrical outlet is within 3 feet of where the
Z-Series panel will mount. If there are no outlets, one will need to be added.
Install enclosure in 4-1/2” deep wall (minimum).
ZPanels are available with or without the zone circulator.
Non-pump ZPanels are designed to be used with P and
D series Hydronex panels. ZPanels with pumps are zone based panels designed on the assumption the main mechanical room piping will be fi eld constructed.
Options for ZPanels include mixing devices, circulators, manifolds, differential by-pass valves, vent/purge assemblies, and individual thermal actuators, depending on the style chosen.
1. Remove and set aside the door.
4. Secure the Main Box in the frame wall.
5. Secure the manifold brackets to the Manifold Support
Bracket using the Locking Rail Nut and Hex Head Bolt.
as needed.
frame and lift. Secure door via the lock.
Refer to the installation manual for further details.
Features
– Wall mounted white powder coated enclosure with locking access cover.
– Pre-wired actuators (specifi c models only).
– Fully enclosed circulator and/or mixing valve
(specifi c models only).
– Stainless Steel manifolds.
Specifications
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Volts
Circulator Type . . . . . . . . . . . . . . . . . . . . .Watts Radiant 15-58
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . Zone Valve Relay Box
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transformer
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Isolation Relay
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Hydronex Z-Series Basic.
Hydronex Z-Series Pump with actuators and differential by-pass valve.
Hydronex Z-Series Pump Mix with actuators and differential by-pass valve.
Product Options
Qty. Description
2 Circuit Stainless Steel Manifold
3 Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold
5 Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold
7 Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold
9 Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold
11 Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold
Circuit Stainless Steel Manifold with ZonePump
3 Circuit Stainless Steel Manifold with ZonePump
Circuit Stainless Steel Manifold with ZonePump
5 Circuit Stainless Steel Manifold with ZonePump
Circuit Stainless Steel Manifold with ZonePump
7 Circuit Stainless Steel Manifold with ZonePump
Part #
ZZone2
ZZone3
ZZone5
ZZone7
ZZone9
ZZone11
ZPumpZone3
ZPumpZone5
ZPumpZone7
Order #
81005851 29.25" x 25.5" x 4.5"
81005852 29.25" x 25.5" x 4.5"
81005854
Panel Size
29.25" x 25.5" x 4.5"
81005856 29.25" x 41.5" x 4.5"
81005857 29.25" x 41.5" x 4.5"
81005792 29.25" x 41.5" x 4.5"
81005794 29.25" x 41.5" x 4.5"
81005866 29.25" x 41.5" x 4.5"
81005867 29.25" x 41.5" x 4.5"
81005868 29.25" x 41.5" x 4.5"
81005870 29.25" x 41.5" x 4.5"
Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone2 81005879
3 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone3 81005880
Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone4 81005881
5 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone5 81005882
Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone6 81005883
29.25" x 41.5" x 4.5"
29.25" x 41.5" x 4.5"
7 Circuit Stainless Steel Manifold, ZonePump, Mix Valve ZMixPumpZone7 81005884 29.25" x 41.5" x 4.5"
81005345
05-349-1139-30-06
USA: 4500 East Progress Place, Springfield, MO 65803; www.wattsradiant.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca