Merlin PowerAce MT60EVO Installation And Operating Instructions Manual
Merlin PowerAce MT60EVO is a sectional garage door opener that combines power, safety, and convenience. With its advanced features, you can control your garage door effortlessly and securely. Here are some of its key features and possible use cases:
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
gomerlin.com.au
gomerlin.co.nz
MT60EVO
Sectional Garage Door Opener
Installation and Operating Instructions
Owners Copy: SAVE THESE INSTRUCTIONS for future reference
This manual contains IMPORTANT SAFETY information
DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY
WARNING!
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS
• Failure to comply with the following instructions may result in serious personal injury or property damage.
• Read and follow all instructions carefully.
• The garage door opener is designed and tested to offer safe service, provided it is installed and operated in strict accordance with the instructions in this manual.
These safety alert symbols mean WARNING : A possible risk to personal safety or property damage exists.
Keep garage door balanced. Do not let the garage door opener compensate for a binding or sticking garage door.
Sticking, binding or unbalanced doors must be repaired before installing this opener.
Do not wear rings, watches or loose clothing while installing or servicing a garage door opener. Wear gloves, safety goggles and suitable protective clothing where appropriate.
The Protector System TM must be used for all installations where the closing force as measured on the bottom of the
door is over 400 N (40 kgf). Excessive force will interfere with the proper operation of the Safety Reverse System or damage the garage door.
S
PECIAL NOTE: Merlin strongly recommends that The
Protector System TM be installed on all garage door openers.
Frequently examine the door installation, in particular cable, springs and mountings for signs of wear, damage or imbalance. Do not use if repair or adjustment is needed since springs and hardware are under extreme tension and a fault can cause serious personal injury.
To avoid serious personal injury from entanglement, remove all ropes, chains and locks connected to the
garage door before installing the door opener.
Installation and wiring must be in compliance with your local building and electrical codes.
After installation, ensure that the parts of the door do not extend over public footpaths or roads.
Install the wireless wall control (or any additional wall control) in a location where the garage door is visible, at a height of at least 1.5 m and out of the reach of children. Do not allow
children to operate push button(s) or transmitter(s). Serious personal injury from a closing garage door may result from misuse of the opener.
Permanently fasten the Warning Labels in Prominent Places, adjacent to Wall Controls and on manual release mechanism as a reminder of safe operating procedures.
The safety reverse system test is very important. Your garage door MUST reverse on contact with a 40 mm obstacle placed on the floor. Failure to properly adjust the opener may result in serious personal injury from a closing garage door. Repeat the test once a month and make any necessary adjustments.
Activate opener only when the door is in full view, free of obstructions and the opener is properly adjusted. No one should enter or leave the garage while the door is in motion.
Automatic Door- The door may operate unexpectedly, therefore do not allow anything to stay in the path of the door.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Do not allow children to play near the door, or with door controls. Keep remotes away from children.
Disconnect electric power to the garage door opener before making repairs or removing covers.
Use the Manual Release only for the seperation of the carriage from the drive and - if possible - ONLY with the door closed. Do not use the red handle to push the door up or pull it down. Operation of the emergency release can lead to uncontrolled movements of the door, if springs are weak or broken or if the door is unbalanced. Mount the release handle of the emergency release at a height less than 1.8 m from the floor.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
This opener should not be installed in a damp or wet space exposed to weather.
To avoid damage to very light doors (such as fibreglass, aluminium or steel doors), an appropriate reinforcement should be added. To do so, contact the door manufacturer.
SAVE THESE INSTRUCTIONS
Warning: If your garage has no service entrance door, a CM1702 outside quick release must be installed. This accessory allows manual operation of the garage door from outside in case of power failure.
CONTENTS PAGE
SAFETY INSTRUCTIONS . . . . . . . . . . .1
BEFORE YOU BEGIN . . . . . . . . . . . . . .2
DOOR TYPES . . . . . . . . . . . . . . . . . . . .2
CARTON INVENTORY . . . . . . . . . . . . .3
RAIL SIZES . . . . . . . . . . . . . . . . . . . . . .3
TOOLS REQUIRED . . . . . . . . . . . . . . . .4
HARDWARE PROVIDED . . . . . . . . . . . .4
COMPLETED INSTALLATION . . . . . . . .4
CONTROL PANEL . . . . . . . . . . . . . . . . .5
ASSEMBLY . . . . . . . . . . . . . . . . . . . . . .6
INSTALLATION . . . . . . . . . . . . . . . . .7-10
OPERATE THE MANUAL RELEASE . .10
ADJUSTMENT . . . . . . . . . . . . . . . .11-12
INSTALL THE PROTECTOR
SYSTEM (OPTIONAL) . . . . . . . . . . . . .13
INSTALL WIRELESS WALL
BUTTON . . . . . . . . . . . . . . . . . . . . . . . .14
TIMER TO CLOSE . . . . . . . . . . . . . . . .14
INSTALL WARNING LABELS . . . . . . .15
PARTIAL OPENING FEATURE . . . . . .15
WIRELESS PROGRAMMING . . . . . . .16
USING YOUR OPENER . . . . . . . . . . .17
CARE OF YOUR OPENER . . . . . . . . .17
REPLACE BATTERIES IN
REMOTE . . . . . . . . . . . . . . . . . . . . . . .17
ACCESSORIES . . . . . . . . . . . . . . . . . .18
REPLACEMENT PARTS . . . . . . . .18-19
TROUBLESHOOTING . . . . . . . . . . 20-21
SPECIFICATIONS . . . . . . . . . . . . . . . .22
WARRANTY . . . . . . . . . . . . . . . . . . . . .23
1
BEFORE YOU BEGIN:
1. Look at the wall and ceiling above the garage door. (The opener and header bracket must be securely fastened to structural supports.)
2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may be required.
3. Do you have an access door in addition to the garage door? If not, model CM1702 Outside Quick Release Accessory is required. This accessory allows manual operation of the garage door from outside in case of power failure.
4. Complete the following test to make sure your garage door is balanced and is not sticking or binding:
• Lift the door about halfway. Release the door. If balanced, it should stay in place, supported entirely by its springs.
• Raise and lower the door to see if there is any binding or sticking, 20 kgf is the absolute maximum allowable force to raise or lower the door in any position. If your door binds, sticks, or is out of balance, call a trained door technician.
1
DOOR TYPES
A. Sectional Door with curved track
To suit spring balanced Residential Sectional doors up to 13.5 m 2 .
Electrical Connection
A 240 V General Purpose Outlet (GPO) ie. Power Point must be available in close proximity to the powerhead.
This fitting is not part of the Opener hardware and must be supplied by the consumer.
2
2
CARTON INVENTORY
Your garage door opener and rail are packed in two seperate cartons. The PowerAce MT60EVO opener carton contains the opener, its fitting hardware and accessories. The rail carton contains the rail and some hardware.
Rails:
Different length rails (2.2 m & 2.4 m) are available for different height doors, ensure you have the correct one.
(1) Opener
(2) Hand held transmitter (2)
(3) Wireless wall control
(4) Curved door arm
(5) Hanging bracket (2)
(6) Rail bracket
(7) Header bracket
(8) Door bracket
(9) Hardware bag
(10) Rail assembly (separate carton)
(11) C-Rail bracket (2)
(12) Manual
(13) Warning Labels
1
4
2 5
3
6
7
13 de en fr da no nl es pt sv
ACHTUNG - Einklemmgefahr
Regelmässig überprüfen und wenn notwendig einstellen um sicher zu sein dass das Tor umkehrt wenn es einen 50 mm hohen Gegenstand berührt der auf den Boden gestellt wurde
CAUTION - Danger of Entrapment
Regularly check and adjust if necessary to ensure that the door reverses when it touches a 50 mm high object that is placed on the floor
ATTENTION - Risque d’écrasement
Vérifier régulièrement et eégler si nécessaire pour s assurer
LET OP - Inklemmingsgevaar
Regelmatig controleren en indien nodig instellen om zeker te zijn dat de poort terugdraait als deze een 50 mm hoog object aanraakt dat op de grond werd geplaatst
Comprobar regularmente y ajustar cuando sea necessario para garatizar que la puerta se invierta cuando toca un objeto de 50 mm de altura que se colocó en el suelo
ATENÇÃO - Perigo de entalamento
Verificar regularmente e se necessário ajustar para se assegurar de que o portão volta para trás ao tocar num objecto com uma altura de 50 mm que foi clocado no chão
ATTENZIONE - Pericolo di incastro
Verificare sistematicamente e se necessario regolare in se viene in contatto con un oggetto alto 50mm posto a terra
ADVARSEL - fare for indklemming
Porten skal kontrolleres og om nøvendigt justeres for at sikre at den går tilbage når den berører en 50 mm høj genstand der er blevet stillet på jorden
FORSIKTIG - Klemmefare
Etter at døren har berørt en gjenstand som har stått 50mm over gulvhøyde må du jevnlig sjekke om døren går feilfritt
Juster om nødvendig
VARNING - klämningsrisk
Kontrollera regelbundet och justera om det behövs för att vara
HUOMIO - puristumisvaara
Tarkista säännöllisesti ja milloin tarpeellista säädä ollaksesi varma että portti kääntyy takaisin kun se koskettaa 50 mm korkeaa kohdetta joka on asetettu maan pinnalle el tr cz hr bg hu sl pl rus cn
A
114A4354 gomerlin.com.au
gomerlin.co.nz
MT60EVO
Sectional Garage Door Opener
Installation and Operating Instructions
OwnersCopy:SAVETHESEINSTRUCTIONSforfuturereference
This manual contains IMPORTANT SAFETY information
DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY
12
3
RAIL SIZES AVAILABLE
8
9
11
10
DOOR HEIGHT:
Sectional Doors
Up to 2.2 m
Up to 2.2 m
Up to 2.4 m
From 2.4 - 3.4 m
BELT & RAIL
PART NUMBER:
8022 CR5
8322 CR5
8024 CR5
840 CR5
RAIL LENGTH:
3000 mm single piece
CEILING FIXING
POINTS: (Standard)
ALTERNATE
FIXING POINT:
2840 mm 2950 mm
3000 mm segmented 2840 mm 2950 mm
3200 mm single piece 3040 mm 3150 mm
1000 mm extension 4040 mm 4150 mm
NOTE: The Ceiling Fixing Point (Standard) is the position of the hanging bracket measured back from the lintel (see item 1 to 7 of “completed installation”). Also allow 400 mm back from the fixing point for installation of the powerhead
(item 7 to 9 of “completed installation”).
The Alternate Fixing Point will position the hanging bracket between the C-Rail brackets, and may line up with a structural support more favourably.
3
4
TOOLS REQUIRED
Drill Bits
10
5
HARDWARE PROVIDED
1 (1x)
6 (1x)
2 (1x)
7 (1x)
3 (4x)
8 (4x)
4 (4x)
9 (8x)
5 (4x)
(1) Truss head screw 6 mm x 80 mm
(2) Lock nut M6
(3) Hexagonal head screw
(4) Nut M8
(5) Flat washer M8
(6) Clevis Pin
(7) R clip
(8) Screw ST6 x 50 mm
(9) Screw ST6,3 x 18 mm
(10) Wallplug
10 (4x)
6
COMPLETED INSTALLATION
As you proceed with the assembly, installation and adjustment procedures in this manual, you may find it helpful to refer back to this illustration of a completed installation.
4
14
1 2
3
4
5
7
6
8
9
11
10
13 12
(1) Header bracket
(2) Belt
(3) Rail
(4) Trolley
(5) Rail connecting piece
(6) Rail bracket
(7) Hanging bracket
(8) Power cord
(9) Opener
(10) Manual release rope & handle
(11) Straight door arm
(12) Curved door arm
(13) Door bracket
(14) C-Rail brackets
4
7
CONTROL PANEL (located under the cover at the rear of the opener)
1
.
External Accessory Power: 30 Vdc 50 mA available for universal receiver (not active in Low standby mode).
2. Terminal Block: used for external accessories (see chart below).
No Function Colour Polarity Comment
0 E-Serial port
1 Push button
2 Ground
2 Ground
3
IR Sensor
4 Door-in-door
5
Door-in-door
6 Flasher
7
Flasher
Green
Red
White
White
Gray
Green
Green
Black
White
+ve
+ve
-ve
-ve
+ve
+ve
-ve
+ve
-ve
Serial Communication Input
Dry Contact input for push button wired wall controls
Common terminal for push button
Common terminal for IR Beams
Merlin IR Beam Input: (pulsing type only)
For Door in Door dry contact sensor: (4&5 are normally linked)
Common terminal for Door in Door sensor
Flashing light output: (24 Vdc 150 mA) while door is in motion
Flashing light output: negative terminal
3. UP Button: used for initial programming, to drive the door UP, and for displaying Diagnostic Code - Digit 1.
4. PROG Button: used to program door limits, and other features.
5. DOWN Button: used for initial programming, to drive the door DOWN, and for displaying Diagnostic Code - Digit 2.
6. LEARN Button: used to program remote controls and learn the forces manually.
7. Indicator LED: used to indicate various programming modes.
8. Green Button: used to activate the door when remote controls are not available. Open - Stop - Close via finger access through the hole in the access cover.
2
1
8
7
30 V DC
+ -
0 1 2 2 3 4 5 6 7
INDICATOR
LED
LEARN
(YELLOW)
UP
PROG
DOWN
3
4
5
6
5
ASSEMBLY SECTION
8
ASSEMBLING THE 3 PIECE SEGMENTED RAIL
NOTE: For 1 piece preassembled rails, proceed to the next step “TIGHTEN THE BELT”.
The segmented rail is largely preassembled and consists of 3 parts. The carriage, push rod, release handle, the guide pulley and the lintel bracket with belt tensioner are in the front part (A). The seating for the drive shaft and the sprocket are in the rear part (B). Hardware items are placed in the rails during transportation - remove these. Lay the front and rear rail sections one behind the other.
1. Remove cable ties that secure the belt. Leave the transport lock (X) still in position.
2. Pull apart the two rail sections completely in order to create a gap for the middle section (C). This rail is designed in such a way so as to easily add the middle section. Slide the 2 connecting pieces (D) over the seams of the rail sections up to the markings. To secure the connecting pieces, bend the sheet metal lugs outwards with a suitable tool. The assembly of the rail is complete.
9
TIGHTEN THE BELT
Note: The spring must be able to compress and bounce during operation. Final tensioning can be performed after installation if necessary. Over tightening the belt may overload the system and cause excessive wear.
1.Tension the belt by adjusting the nut (1), on the pulley assembly, clockwise until the spring is engaged.
2.Continue tightening to compress the spring and remove all the slack in the belt. DO NOT OVERTIGHTEN but ensure belt is firm.
3.37-41 mm as indicated in the diagram is normal.
10
FASTEN RAIL TO OPENER
1.Slide the RAIL BRACKET (1) onto the powerhead end of the rail (A) around 200 mm.
2.Remove transport lock (X). Check if the belt is seated on the gearwheel. If it has slipped off during assembly, relax the spring and tighten again.
3.Position the rail drive spocket (2) over the opener motor shaft
(3) and push down to install.
4.Secure the rail on the opener with two C-Rail brackets (4) and the screws (5).
This completes the assembly of the door opener to the rail.
6
1
1
37 - 41 mm
X
2
3
5
4
A
INSTALLATION SECTION
Wear protective goggles when working overhead to protect your eyes from injury.
Disengage all existing garage door locks to avoid damage to the garage door.
11
HEADER BRACKET POSITIONING
The header bracket must be rigidly fastened to a structural support of the garage. Reinforce the wall or ceiling with a 40 mm (1-1/2") board if necessary. Failure to comply may result in improper operation of safety reverse system.
You can attach the header bracket either to the header wall
(1) or to the ceiling (3). Follow the instructions which will work best for your particular requirements.
With the door closed, mark the vertical centre line (2) of the garage door. Extend line onto header wall above the door.
Open door to highest point of travel. Draw an intersecting horizontal line (4) on header wall at least 50 mm above high point to provide travel clearance for top edge of door.
Header Wall
4
Unfinished
Ceiling
2
3
OPTIONAL
CEILING
MOUNT
FOR
HEADER
BRACKET
1
Structural
Supports
Level
(optional)
2
12
INSTALL THE HEADER BRACKET
NOTE: Refer to vertical centre and horizontal lines created in the previous section for proper placement of header bracket.
A. Wall mount: centre the header bracket (1) on the vertical centre line (2) with the bottom edge of the header bracket on the horizontal line (4) (with the arrow pointing toward the ceiling). Mark all of the header bracket holes (5). Drill 4.5 mm
(3/16") pilot holes and fasten the header bracket with wood screws (3).
B. Ceiling mount: extend vertical centre line (2) onto the ceiling.
Centre the header bracket (1) on the vertical mark no more than 150 mm (6") from the wall. Make sure the arrow is pointing toward the opener. Mark all of the header bracket holes (5). Drill 4.5 mm (3/16") pilot holes and fasten the header bracket with wood screws (3). For concrete ceiling mount, use concrete anchors provided.
5 up to
200 mm
5
(50 to 200 mm depending on door type)
50 mm
150 mm
(6")
1 2
3
A
4
2
1
3
4
2 1
3
13
ATTACH RAIL TO HEADER BRACKET
Attach the Rail to the Header Bracket
• Position the assembled opener on the garage floor below the header bracket. Use foam packing material as a protective base.
NOTE: If the door spring is in the way youʼll need help.
Have someone hold the opener securely on a temporary support to allow the rail to clear the spring.
• Position the rail bracket against the header bracket.
• Align the bracket holes and secure with the 80 mm trusshead screw and locknut (1) and (2).
2
1
7
14
POSITION THE OPENER
Disengage the trolley mechanism (see section “Operating the manual release”) and slide it back towards the powerhead.
Secure the hanging push arm up into the rail assembly temporarily using tape or rope, to avoid a hazard.
SECTIONAL DOOR
You will need a 50 mm piece of timber or similar spacer to gauge the distance between door and rail.
1.Raise the opener onto support.
2.Open the door completely, place a 50 mm spacer between the door and the rail (as shown).
3.The final positioning of the rail should be relatively parallel to the horizontal door panels.
Header
Bracket
50 mm (2”) above the highest point of travel
Rail
Door
50 mm spacer should be used to determine the correct mounting position
8
15
HANG THE OPENER
1.Postion the opener as in the previous step. Check the rail is centred over the door.
2.Ensure the rail brackets (1) is on the Powerhead end of the rail in a position as close to the opener as possible
(X).
3.If mounting directly onto the ceiling, (2) screw the bracket directly into a structural support on the ceiling.
4.If hanging the opener below the ceiling, (3 & 4) bend the hanging brackets provided, and secure to both the ceiling and rail bracket.
5.Check the opener is securely centred over the door.
Remove the 50 mm spacer, and any other assembly tools. Operate the door manually and check for unrestricted operation.
2
1
3
A
4
X
16
FASTEN DOOR BRACKET
The door bracket must be securely fastened to the frame or a structural support on the door.
Mounting position for Sectional Doors
1.Align the bracket on the centre line, measure down 100-
300 mm from the door top edge.
2.Secure the bracket in this position, using the most suitable variation of holes available.
A
1
100-300 mm
9
17
ATTACH DOOR ARM TO TROLLEY
Make sure the garage door is fully closed. Pull the manual release cord to disengage the trolley. Slide the trolley to around 300 mm from the header bracket.
1.The straight door arm is already preassembled to the trolley.
2.Install the curved arm onto the door bracket using the Clevis pin (2) and R-Clip (3) supplied.
3.Move the straight and curved arms together and secure using two bolts and nuts provided (4). Ensure the angle of the straight arm is around 20 degrees from vertical, when the door is fully closed.
Alternate Arm Configuration: The curved arm can be assembled directly to the trolley assembly if required (see figure 3). Unscrew the front two screws in the trolley assembly. Remove the straight arm pivot and reassemble with the curved arm bracket.
3
2
1
Fig. 1
5
Trolley Screws
4
Fig. 3
Fig. 2
18
OPERATING THE MANUAL RELEASE
DO NOT DISENGAGE THE OPENER TO MANUAL
OPERATION WITH CHILDREN , PERSONS OR OTHER
OBJECTS INCLUDING MOTOR VEHICLES WITHIN THE
DOORWAY : (The door is under significant tension and if the door has developed a fault or incorrect tension, it may be unsafe and may fall rapidly.)
The manual release mechanism enables the door to be manually operated during power outages or in an emergency.
The RED Manual Release cord is preassembled to the trolley. When the opener is installed the handle should be no higher then 1.8
metres from the floor. The cord may need to be extended.
Attach the manual release Instruction Label to the cord as indicated in fig 1.
DO NOT USE THE RED HANDLE TO OPEN AND CLOSE THE
DOOR.
1
2
Instruction label
To operate the Manual Release:
1.The door should be fully closed if possible.
2.Disengage: Pull the manual release rope and handle down once to disconnect. This will disengage the trolley, allowing the door to be moved by hand, UP and DOWN as many times as needed.
3.Re-engage: Press the “GREEN” button in the centre of the trolley assembly. This will re-engage the trolley, and when the door passes the trolley position it will automatically re-engage the opener.
Connect Electric Power
TO AVOID INSTALLATION DIFFICULTIES, DO NOT RUN THE GARAGE DOOR OPENER UNTIL INSTRUCTED TO DO SO.
Connect to properly fused and earthed power outlet.
-
Ensure all ropes and installation tools have been removed from the door.
- When the opener is switched ON, the operator light flashes a number of times and then remains ON.
10
ADJUSTMENT SECTION
19
PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS
figure 1
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing door.
• Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
• NEVER use force adjustments to compensate for a binding or sticking garage door.
• After ANY adjustments are made, the safety reversal system MUST be tested. Door MUST reverse on
contact with 40 mm high object laid flat on floor.
which activates a mechanical passpoint during the door travel.
The indicator LED will blink when this occurs. If the passpoint
TO PROGRAM THE TRAVEL LIMITS:
1. Press the PROG Button until the UP Arrow Button and indicator
LED begin to flash (figure 2).
desired UP position (figure 3).
To prevent damage to vehicles, be sure fully open door provides adequate clearance.
figure 2
Indicator LED
4).
4. Press and hold the DOWN Arrow Button until the door is in the desired DOWN position (figure 5).
NOTE: The UP and DOWN Arrow Buttons can be used to move the door up and down as needed.
5. Once the door is in the desired DOWN position press and release figure 3
Indicator LED
SETTING THE FORCE (AUTO):
6. Press and release the UP Arrow Button to test the UP limit. When
Arrow Button will begin to flash.
7. Press and release the DOWN Arrow Button to test the DOWN limit. The door will travel to the programmed DOWN limit.
setting has now been set. Proceed to test safety reverse system.
SETTING THE FORCE (MANUAL LEARN IF REQUIRED):
1. Open the rear access panel. Locate the yellow Learn button.
adjustment mode. The LED (indicator light) will flash quickly.
3. Push the programmed remote control or push the UP/DOWN figure 4
Indicator LED will travel to the UP (open) position.
limit. The door will travel to the programmed DOWN limit.
The LED (indicator light) will stop flashing when the force has been set. The door must travel through a complete cycle, UP and DOWN, in order for the force to be set properly. If the unit cannot open and close your door fully, inspect your door to insure that it is not sticking or binding.
The Force Setting has now been set manually.
11 figure 5
Indicator LED
20
TEST THE SAFETY REVERSE SYSTEM
The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing garage door. Repeat test once a month and adjust as needed.
Procedure: With door opened place a 40 mm obstacle (1) laid flat on the floor under the garage door. Operate the door in the down direction. The door must reverse off the obstacle. If the door stops on the obstacle, remove obstacle and repeat Program the Limits and Force Steps, then repeat safety reverse test.
When the door reverses off the 40 mm obstacle, remove the obstacle and run the opener through a complete travel cycle. Door must not reverse in closed position. If it does, repeat Program the Limits and Force then repeat safety reverse test.
40mm 1
21
PROGRAM THE LOW STANDBY MODE (OPTIONAL)
Low Standby Mode (sub 1 watt) is activated by the factory to deliver the lowest possible standby power.
In this mode the External Accessories Power and the IR Beams are turned OFF when the door is closed and the courtesy light is OFF.
At mains turn ON: Courtesy light flashes 2 times = Low Standby Mode
Courtesy light flashes 10 times = Normal Standby Mode
The Normal Standby Mode will need to be activated for External Accessories Power.
To Activate Normal Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 10 flashes.
Release the arrow buttons.
To Activate Low Standby Mode:
Turn the mains power OFF.
PRESS and HOLD both the UP and DOWN arrows simultaneously.
Turn ON mains power while both the arrow buttons are still pressed.
Courtesy light comes on and after 5 seconds another 1 flash.
Release the arrow buttons.
12
22
INSTALL THE PROTECTOR SYSTEM
TM
(OPTIONAL)
NOTE: This accessory must be used for all installations where the closing force as measured on the bottom of the door is over 400 N (40 kgf).
S openers.
TM be installed on all garage door
IR BEAMS: By installing IR Beams, an open door is prevented from closing if a person or object is located in the beam area. If the door is already closing, it will return to the open position. A closed door is not prevented from opening.
If the Protector System TM is installed and needs to be removed, the opener will need to be reprogrammed (refer to paragraph 4 of the troubleshooting section).
NOTE: A complete set of installation and setup instructions are supplied with the accessory item.
Figures 1, 2 and 3 show recommended assembly of bracket(s) and "C" wrap based on the wall installation of the sensors on each side of the door shown above, or on the door tracks themselves. Figure 4 shows variations which may fit your installation requirements better. Make sure the wraps and brackets are aligned so the sensors will face each other across the door.
• Connect each assembly to a slotted bracket, using the hardware shown. Note alignment of brackets for left and
right sides of the door. Finger tighten the lock nuts.
• Use bracket mounting holes as a template to locate and drill two (4.8 mm) diameter pilot holes on both sides of the door so that the beam mounting height is no greater than 100 mm above the floor.
• Attach bracket assemblies with carriage bolts as shown.
• Adjust right and left side bracket assemblies to the same distance out from mounting surface. Make sure all door hardware obstructions are cleared. Tighten the lock nuts.
• Centre each sensor unit in a "C" wrap with lenses pointing toward each other across the door.
• Secure sensors with the hardware provided. Finger tighten the wing nut on the receiving eye to allow for final adjustment.
Securely tighten the sending eye wing nut.
• Run wires from both sensors to the opener and connect the two white only wires to the white terminal (2) and the black/white wires to the grey terminal (3) on your opener (refer figure 5).
T o prevent entrapment, install The Protector
System™ no higher than 100 mm above the floor.
Disconnect power to the garage door opener before installing The Protector System™.
Lock Nuts
ALL INSTALLATIONS
Mount Bracket
With Square Holes
“C” Wrap figure 1 figure 2
Installing The Protector System TM to the Garage Wall
Lag Screws
Carriage Bolts
(with Square Shoulders)
Garage
Wall
Lock Nuts figure 3
Installing The Protector System TM to Track
Garage
Track
Garage wall
Lock Nuts
Mounting Brackets with Square Holes
Drill
9.5 mm
Holes
Carriage Bolts
Screws
Mounting Bracket with slot
Mounting Bracket with Square Holes
“C” Wrap
“C” Shaped
Wrap figure 5
Alternate Wall Mount
Garage
Wall Mounting
Bracket with Holes
Mounting Bracket with Square Holes
“C” Wrap
Sensor
Indicator Light
Garage
Floor figure 4
Alternate Floor Mount
Garage
Wall
Holder
Garage-
Floor
Indicator
Lamp
Sensor
Mounting Bracket with Square Holes
Mounting Bracket with Slot
Attach with concrete anchors
(not provided) red white
6mm
To release wires press tab with a screwdriver or pen
13
23
TIMER TO CLOSE FEATURE (TTC)
Door may operate unexpectedly, therefore do not allow anything to stay in the path of the door.
(IR Beams) to be installed.
TM
Operation: figure 1
Indicator LED figure 2
Indicator LED
To Activate TTC, or change a preset time:
1.Start with the door fully CLOSED.
2.Enter into TTC Activation mode by pressing both PROG and DOWN buttons together for 3 seconds (figure 1).
Release when the courtesy light flashes twice.
3.Press the UP button once for each 10 second increment required of TTC (figure 2. eg. twice for 20 seconds). Press the DOWN arrow to reduce, if needed.
4.Press and release the PROG button to save this time
(figure 3), Courtesy light will flash once. TTC is now activated.
TEST: Operate the door to the UP position. Keep clear of the
IR Beams and check the door closes after the preset time.
To Deactivate TTC:
1.Enter into TTC Activation mode by pressing both PROG and DOWN buttons together for 3 seconds (figure 1).
Release when the courtesy light flashes twice.
2.Press and release the PROG button to save (figure 3), courtesy light will flash once. TTC is now deactivated.
figure 3 figure 4
Indicator LED or
24
INSTALLING YOUR E138M WIRELESS WALL BUTTON
NOTE: The wall control supplied with your opener should be pre-programmed by the factory.
If adding a new wall control, program into the opener before mounting the unit as detailed in Wireless Programming.
Disconnect power to the opener before installing this accessory to prevent accidental activation.
Locate minimum 1.5 m above the floor.
To install:
• Carefully pry open the E138M and locate the two screws for mounting.
• Attach to the wall using the two screws provided. If mounting to a plaster wall, wall plugs may be required.
NOTE: Do not overtighten screws.
• Replace the front cover plate.
+
14
25
INSTALL WARNING LABELS
2
1
3 da no sv de en es pt
ACHTUNG - Einklemmgefahr
Regelmässig überprüfen und wenn notwendig einstellen um hohen Gegenstand berührt der auf den Boden gestellt wurde sicher zu sein dass das Tor umkehrt wenn es einen 50 mm
CAUTION - Danger of Entrapment
Regularly check and adjust if necessary to ensure that the is placed on the floor door reverses when it touches a 50 mm high object that
Vérifier régulièrement et eégler si nécessaire pour s assurer ATTENTION - Risque d écrasement que la porte inverse son mouvement lorsqu elle rencontre un objet de 50 mm de haut placé sur le sol
LET OP - Inklemmingsgevaar
Regelmatig controleren en indien nodig instellen om zeker te zijn dat de poort terugdraait als deze een 50 mm hoog object aanraakt dat op de grond werd geplaatst
ATENCIÓN - Peligro de aprisionamiento
Comprobar regularmente y ajustar cuando sea necessario para garatizar que la puerta se invierta cuando toca un objeto de 50 mm de altura que se colocó en el suelo
ATENÇÃO - Perigo de entalamento
Verificar regularmente e se necessário ajustar para se objecto com uma altura de 50 mm que foi clocado no chão assegurar de que o portão volta para trás ao tocar num
Verificare sistematicamente e se necessario regolare in ATTENZIONE - Pericolo di incastro maniera adeguata onde assicurare che la porta torni indietro se viene in contatto con un oggetto alto 50mm posto a terra
ADVARSEL - fare for indklemming
Porten skal kontrolleres og om nøvendigt justeres for at sikre at den går tilbage når den berører en 50 mm høj genstand der er blevet stillet på jorden
FORSIKTIG - Klemmefare
Etter at døren har berørt en gjenstand som har stått 50mm over gulvhøyde må du jevnlig sjekke om døren går feilfritt
Juster om nødvendig
VARNING - klämningsrisk
Kontrollera regelbundet och justera om det behövs för att vara föremål som placerats på golvet säker på att porten vänder när den träffar ett 50 mm högt
HUOMIO - puristumisvaara
Tarkista säännöllisesti ja milloin tarpeellista säädä ollaksesi korkeaa kohdetta joka on asetettu maan pinnalle varma että portti kääntyy takaisin kun se koskettaa 50 mm cz hr rus cn bg hu
A B B
114A4354
Three warning labels are provided with this opener: attach as indicated in the fig 1.
• Danger of entrapment: (English version) - place close to a fixed Wall Control(1).
• Service label: - place on the Manual Release cord (2).
• Caution Child Entrapment: (triangle label) - place on a low inside panel of the door (3).
26
PARTIAL OPENING FEATURE (PET)
This is an adjustable, second stop position suitable for ventilation, pedestrian or pet access, programmed to the Remote
Control or Wireless Wall button.
To Activate this feature:
1.Start with the door fully CLOSED. Drive the opener UP and stop at the position required for PET access.
2.Enter PET activation mode by pressing the PROG and UP buttons together for 3 seconds (figure 1). Release when the
Courtesy light flashes once.
figure 1 figure 2
Indicator LED
3.Press the Remote Control button that you have allocated for this feature (figure 4). Do not use the button already allocated for normal operation. The Courtesy light will flash once when the code is accepted.
Indicator LED
TEST: Press the Remote Control once, and door will close, press again, and door will return to the preset position.
If the door is above the preset position, when the button is pressed, it will fully close.
To Deactivate this feature:
1.Start with the door fully CLOSED.
2.Enter PET Activation mode by pressing the PROG and UP buttons together for 3 seconds (figure 1). The Courtesy light will flash twice, indicating the deactivation has occurred.
NOTE: Erasing all remote control codes, as in the Wireless programming section, will also delete this feature.
figure 3 figure 4
Indicator LED or
15
27
WIRELESS PROGRAMMING (OPTIONAL ACCESSORIES)
Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave garage while door is in motion. Do not allow children to operate push button(s) or remote(s).
Do not allow children to play near the door.
NOTE: The transmitter(s) and wireless wall button supplied with your opener are preprogrammed by the factory.
If you purchase additional transmitters, the garage door opener must be programmed to accept the new remote code.
Program the Receiver to Match Additional Transmitter Codes:
Using the yellow “LEARN” Button
1.Press and Hold the button on the hand-held remote or wall button that you wish to use (1).
2.Press and release the yellow “LEARN” buton on the opener (2).
3.Release the remote button when the opener light flashes. It has learnt the code. If you release the remote control push button before the opener light flashes, the opener has not learned the code.
Now the opener will operate when the remote control push button is pressed.
1
To Erase all Remote Control Codes
1.Press and Hold the yellow “LEARN” button on the opener until the indicator LED goes ON, and continue holding for approx. 6 seconds, until the indicator LED goes out.
1.Release the button, all codes are now erased.
2
2
Yellow “Learn” Button
1
Locate the yellow learn button
Press and release the yellow learn button
Wireless Keypad E840M
To set the keyless entry PIN:
1.Locate the yellow “LEARN” button on the garage door opener.
2.Press and release the yellow “LEARN” button. The LED indicator light will glow steadily.
3.Enter a 4-digit personal identification number (PIN) of your choice on the keypad.
3
4
4.Press and hold the ENTER button. Check to see if the opener light flashes. Release the ENTER button after the light flashes.
To change an existing keyless entry PIN:
1.Enter the existing programmed PIN that you want to change.
2.Press and hold the # button until the courtesy light flashes twice.
3.Enter the new 4-digit PIN of your choice, then press the ENTER button. The light will flash once.
4.To test, enter the new PIN, then press the ENTER button. The garage door opener will activate.
3
16
Enter a 4-digit
PIN of your choice
Press and hold the enter button
Opener light flashes
After the lights flash release the
ENTER button
28
USING YOUR OPENER
MAINTENANCE AND CARE OF YOUR OPENER
30
REPLACE BATTERIES IN REMOTES
Battery of the remote control:
1. Your opener can be activated by any of the following devices:
• Opener control panel: Up and Down Buttons and Green O.S.C.
• The Outside Keyswitch or Keyless Entry System (if you have installed either of these accessories).
• The Remote Control Transmitter. Hold the push button down until the door starts to move.
2. Opening the Door Manually: Door should be fully closed if possible. Weak or broken springs could allow an open door to fall rapidly. Property damage or serious personal injury could result.
NOTE: For full instructions on how to operate the door manually refer to section 18.
The door can be opened manually by pulling the release handle down. To reconnect the door, press the Green button in the centre of the trolley assembly.
Do not use the manual release handle to pull the door open or closed.
3. When the Opener is Activated by Remote Control:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop.
3. If opening, the door will stop (allowing space for entry and exit of pets and for fresh air).
4. If the door has been stopped in a partially open or closed position, it will reverse direction.
5. If an obstruction is encountered while closing, the door will reverse to the UP limit.
6. If an obstruction is encountered while opening, the door will reverse and stop.
7. The optional Protector System™ uses an invisible beam which, when broken by an obstruction, causes a closing door to open and prevents an open door from closing. It is STRONGLY
RECOMMENDED for homeowners with young children.
4. The opener lights will turn on under the following conditions: when the opener is initially plugged in; when power is restored after interruption or when the opener is activated.
Lights will turn off automatically after 2-1/2 minutes.
The batteries in the remote have an extremely long life.
If the transmission range decreases, the batteries must be replaced. Batteries are not covered by the warranty.
To prevent SERIOUS INJURY OR DEATH: observe the following instructions for the battery
- NEVER allow small children near batteries.
- If battery is swallowed, immediately notify doctor.
- Danger of explosion if battery is replaced improperly.
- Replacement only by identical or equivalent type.
- Dispose of old battery properly. Batteries should not be treated as household waste. All consumers are required by law to dispose of batteries properly at the designated collection points.
- Never recharge batteries that are not meant to be recharged.
- Do not short-circuit batteries or take them apart.
- If necessary, clean contacts on batteries and contacts before loading.
- Never expose batteries to excessive heat such as sunshine, fire or the like!
Replacing battery (CR2032):
To replace battery, turn remote control around and open the case with a screwdriver. Lift cover and lift control board below.
Slide battery to one side and remove. Observe polarity of battery!
Assemble again in reverse direction.
12 VD
C
29
CARE OF YOUR OPENER
Once a Month
• Manually operate door. If it is unbalanced or binding, call a qualified door technician.
• Check to be sure door opens & closes fully. Adjust limits and/or force if necessary.
• Repeat the safety reverse test. Make any necessary adjustments.
Once a Year
• Lightly grease the belt and inside the rail assembly where the trolley slides.
• Internally the opener does not require additional lubrication.
Pb Cd Hg
To replace battery for optional remote control transmitters -
E943M, E940M & E945M, use a screwdriver blade to pry open the case as shown. Insert battery positive side up.
Carefully
Remove Battery
(CR2032 x 1) or
17
31
ACCESSORIES
(1) Model E128M
(2) Model E138M
(3) Model E950M
(4) Model E940M
(5) Model E943M
(6) Model E945M
E128M
Wireless wall button
Wireless wall button
4 Channel remote control
1 Channel visor remote control
3 Channel visor remote control
3 Channel mini remote control
E138M E950M
(7) Model E840M
(8) Model C77
(9) Model CM1702
(10) Model 760E
(11) Model FLA24
E940M E943M
Keyless entry system
The Protector System TM
Quick release lock
Outside keyswitch
Flashing light
E945M
E840M
1
C77
2
3
CM1702
4
760E
5
FLA24
6
9 10 11
7
32
REPLACEMENT PARTS
041A4038
Pulley assembly
004C5600
Hardware bag
8
002A1800
Trolley with rope & straight arm
041A4017-1
Motor shaft adapter (metal)
041A4020R
Sprocket assembly
083A0011
Grease
041A4016R
Position tab (belt)
Segmented rail assembly
8322CR5
04
1A
40
41 d
Se gm en te ra il b ra ce s
04
1A
Se gm en te d
40
42 ra il s ec tio ns
One piece rail asssembly
8022CR5 2.2 m
8024CR5 2.4 m
041A4021R
Trolley latch (belt)
178A0104
Curved arm
178A0103
Straight arm
Replacement belt packs
041A4045-1 (2.2m)
041A4045-2 (2.4m)
004C5502
Door bracket
012C0788-1
Header bracket
18
041A4039
C-Rail bracket
012C0778
Hanging brackets
012A1028
Rail bracket
33
REPLACEMENT PARTS
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid hazard.
041A4004
Passpoint
Assembly
Power Cord
026B0181
041A4022A
Logic Board / PCB Housing / Control Cover (assembly)
041A4002-1
LED Module
041A4024
Transformer
041A4023-1
Power Board
041A4033
Motor Assembly
041A1805
Lens Cover
041A1802
Chassis Cover
041A1804
Brand Cover
19
34
TROUBLE SHOOTING
1. Opener doesn't operate from either door control or remote:
• Does the opener have electric power? Plug lamp into outlet. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)
• Have you disengaged all door locks? Review installation instruction warnings on page 1.
• Is there a build-up of ice or snow under door? The door may be frozen to ground. Remove any obstruction.
• The garage door spring may be broken. Have it replaced.
2. Door operates from door control but not from remote:
• Replace batteries in the remote if necessary.
• If you have two or more remotes and only one operates, review Program Your Opener, Remote and Keyless
Entry.
3. Remote has short range:
• Check the battery in the remote is fully charged.
• Change the location of the remote control in the car.
• A metal garage door, foil-backed insulation or metal siding will reduce the transmission range.
4. Door reverses for no apparent reason and opener light flashes 10 times:
• Check The Protector System™ (if you have installed this accessory). If the light is flashing, correct alignment.
If the Protector System TM is installed and needs to be removed, the Opener will need to be reprogrammed as follows:
• Remove the IR Beam wiring from the Opener
• Turn the power OFF for 5 seconds
• Turn the power ON for 5 seconds
• Again turn the power OFF for 5 seconds
• Turn the power back on and test the opener for normal operation.
5. The garage door opens and closes by itself:
Make sure remote push button is not stuck "on".
6. Door stops but doesn't close completely:
Repeat Programming the Travel Limits.
Repeat safety reverse test after any adjustment of door arm length, close force or down limit adjustments.
7. Door opens but won't close:
• Check The Protector System™ (if you have installed this accessory). If the light on the Beams are flashing, correct the alignment.
• If opener light does not flash and it is a new installation, repeat Programming the Travel Limits.
Repeat the safety reverse test after the adjustment is complete.
8. Opener strains:
Door may be unbalanced or springs are broken. Close door and use manual release rope and handle to disconnect trolley. Open and close door manually. A properly balanced door will stay in any point of travel while being supported entirely by its springs. If it does not, call for professional garage door service to correct the problem.
9. Opener hums briefly, then won't work:
• Garage door springs are broken. SEE ABOVE.
• If problem occurs on first operation of opener, door is locked. Disable door lock.
Repeat safety reverse test after adjustment is complete.
10. Opener won't activate due to power failure:
• Pull manual release rope and handle down once to disconnect trolley. Door can be opened and closed manually. When the power is restored, press the
“GREEN” button in the centre of the trolley assembly.
The next time the opener is activated, the trolley will reconnect.
• The Outside Quick Release accessory (if fitted) disconnects the trolley from outside the garage in case of power failure.
11. The Up and DOWN arrows on the control panel are flashing in sequence:
Check the diagnostic code on next page.
20
35
DIAGNOSTIC CHART
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage opener flash the diagnostic codes.
DIAGNOSTIC CODE SYMPTOM POSSIBLE RESOLUTION
UP Arrow DOWN Arrow
Flash(es) Flash(es)
1 1 The garage door opener will not close and the courtesy light flashes.
1 2 The garage door opener will not close and the courtesy light flashes.
Safety sensors are not installed, connected or wires may be cut. Inspect sensor wires for a disconnected or cut wire.
There is a short or reversed wire for the safety sensors. Inspect safety sensor wire at all staple points and connection points and replace wire or correct as needed.
1 3 The door control will not function.
1
1 4
5
The garage door opener will not close and the courtesy light flashes.
There is no door movement or very slight.
The wires for the door control are shorted or the door control is faulty. Inspect safety sensor wire at all staple points and connection points and replace wire or correct as needed.
Safety sensors are misaligned or were momentarily obstructed. Realign both sensors to ensure both LEDs are steady and not flickering. Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing.
No RPM pulses have been detected. Check the door manually for balance, binding or obstructions. Internally the possible cause may be the motor, logic board or travel module. Try resetting door travel limits. Contact service centre.
1 6
2
2
3
3
4
4
4
5
1-5
6
2
3
1-4
5
6
1-5
Door continues to move after the motor stops.
Opener fails to operate.
RPM pulses have been detected after motor has turned off. Possible broken spring. Check the door is correctly balanced and not creeping up or down.
Contact a door service centre.
Possible logic board failure. Reboot opener by turning the mains power OFF and then ON after 15 seconds. Reprogram the door travel limits and force settings. Contact service centre.
Check the passpoint module has been activated by the belt Position Tab, during the door travel. Reset the travel limits.
Unable to set travel limit down direction. Passpoint has not been recognised during programming.
Unable to set the travel or retain position.
Check travel module for proper assembly, replace if necessary.
The battery status LED* is constantly flashing green.
Battery backup charging circuit error, replace logic board. *(if applicable)
Door is moving stops and or reverses.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock. If the door is binding or sticking contact a trained door systems technician. If door is not binding or sticking attempt to reprogram travel (refer to page 24 ).
Opener runs approximately 150 mm to 200 mm, stops and reverses.
The garage door opener will not close and the courtesy light flashes.
Door fails to operate or operates erractically. External accessory wiring failure.
Communication error to travel module. Check travel module connections, replace module if necessary.
Safety sensors are misaligned or were momentarily obstructed. Realign both sensors to ensure both LEDs are steady and not flickering. Make sure nothing is hanging or mounted on the door that would interrupt the sensor's path while closing.
Check the external wiring to the control panel terminal is wired correctly. Turn off power, remove all external wiring, and retest door operation.
21
36
SPECIFICATIONS - PowerAce - MT60EVO
Input Voltage...........230-240 Vac, 50 Hz
Max. Pull Force ......600 N
Power .....................150 Watt
Standby Power .......0.8 Watt (door fully closed)
Normal Torque........5 Nm
Max door weight......70 kgs Spring balanced
Max door area.........Sectional door 13.5 m 2
Motor
Type........................DC gearmotor permanent lubrication
Noise level..............54 db at 1 metre
Drive Mechanism
Drive .......................Belt with one-piece trolley on steel rail.
Length of Travel......Adjustable to 3.0 m
LED light .................25 Watt equivalent
Door Linkage ..........Adjustable door arm. Pull cord trolley release.
Safety direction.
Electronic................Automatic force adjustment
Electrical .................Transformer overload protector and low voltage push button wiring.
Limit Device............Mechanical Passpoint/RPM sensor
Limit Adjustment .....Electronic
Soft-start/Soft-stop
Dimensions
Length (Overall).......3.24 m
Headroom Required 30 mm
Hanging Weight.......11 kg
Receiver
Memory Registers ...64 handset codes
4 keypad devices - 1 code each
Operating
Frequency.................433.30/433.92/434.54 MHz
22
CHAMBERLAIN LIMITED WARRANTY
Merlin Professional MT60EVO PowerAce
Sectional Garage Door Opener
Chamberlain Australia Pty Limited / Chamberlain New Zealand Limited
(Chamberlain), the manufacturer of Merlin ® automatic garage door openers, is committed to manufacturing and supplying high quality goods.
As part of this commitment, we seek to provide reliable service and support for our goods and are pleased to provide you, the original purchaser, with this Chamberlain Limited Warranty.
We also provide the following statement as required by the Australian
Consumer Law: In Australia, in addition to your rights under this
Chamberlain Limited Warranty, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Chamberlain’s warranty
Chamberlain warrants to the original purchaser of the Merlin ® MT60EVO
Sectional Door Opener (Unit) that all parts of the Unit, other than remote controlled transmitters and accessories, globes and batteries, are free from defects in materials and workmanship for a period of 24 months or
5,000 cycles (opening & closing of the garage door) whichever comes first, from the date of purchase when installed in a residential premise with a residential specified garage door that is designed for the sole purpose of domestic domicile. Chamberlain warrants that remote controlled transmitters and accessories included with the Unit are free from defects in materials and workmanship for a period of 12 months from the date of purchase.
Batteries and globes are not covered under the Chamberlain Limited
Warranty.
It is a condition of this Chamberlain Limited Warranty that the Unit is sold, installed and serviced by a Professional Dealer appointed by
Chamberlain. A Merlin ® branded garage door opener purchased over the internet and installed by a person other than a Professional Dealer will not be covered by this Chamberlain Limited Warranty.
During the applicable Chamberlain Limited Warranty period, if you are concerned that the Unit may be defective, for prompt on-site service call the Professional Dealer that sold/installed the opener, or our service centre on the toll free number below and a Chamberlain technician will diagnose the problem and arrange for this to be rectified. Once the problem has been diagnosed, subject to your rights under the Australian
Consumer Law with respect to major failures, Chamberlain or its
Professional Dealer will provide you with:
1. repairs to the Unit or
2. a replacement Unit.
Repairs and replacement parts provided under this Chamberlain Limited
Warranty are provided free of charge and are warranted for the remaining portion of the original warranty period.
This Chamberlain Limited Warranty provides benefits which are in addition to your other rights and remedies as a consumer.
Exclusions
If our service centre determines that a warranty claim has been made in respect of a failure or defect arising under or out of any exclusion detailed below such that the claim is not covered under this Chamberlain Limited
Warranty, we may, subject to your other rights and remedies as a consumer, charge you a fee to repair, replace and/or return the Unit to you.
This Chamberlain Limited Warranty does not cover any failure of, or defect in, the Unit due to:
1 non-compliance with the instructions regarding installation, operation, maintenance and testing of the Unit or of any product with which the Unit is used;
114D4643A 23
2 any attempt by a person other than a Professional Dealer to repair, dismantle, reinstall or move the Unit to another location once it has been installed;
3 tampering, neglect, abuse, wear and tear, accident, electrical storm, excessive use or conditions other than normal domestic use;
4 problems with, or relating to, the garage door or garage door hardware, including but not limited to the door springs, door rollers, door alignment or hinges;
5 problems caused by electrical faults or replacement of batteries or light bulbs;
6 water or moisture ingress that causes corrosion or electrical malfunction;
7 corrosion caused by sea air if located near a waterway, beach etc; or
8 fitment to a commercial door or in a commercial operating application.
NB: A General Purpose Outlet (GPO) ie: power point must be supplied by the consumer as this electrical fitting does not form a part of the Unit
(opener).
If this Chamberlain Limited Warranty does not apply, you may have rights available to you under the Australian Consumer Law.
Liability – Australia only
Except as set out in the Australian Consumer Law (being Schedule 2 of the Competition and Consumer Act 2010) (as amended, consolidated or replaced):
1 all other guarantees, warranties and representations in relation to the
Unit or its supply are excluded to the extent that Chamberlain can lawfully exclude them; and
2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages arising in connection with the use, or inability to use, the Unit, other than those which were reasonably foreseeable as liable to result from the failure.
Liability – New Zealand only
Except as set out in the Fair Trading Act 1986 and the Consumer
Guarantees Act 1993 (as amended, consolidated or replaced):
1 all other guarantees, warranties and representations in relation to the
Unit or its supply are excluded to the extent that Chamberlain can lawfully exclude them; and
2 under no circumstances will Chamberlain be liable for consequential, incidental or special damages arising in connection with the use, or inability to use, the Unit, other than those which were reasonably foreseeable as liable to result from the failure.
Note
We request that you retain your sales docket or invoice as proof-ofpurchase and attach it to this manual to enable you to establish the date of purchase in the unlikely event of a warranty service being required.
Chamberlain reserves the right to change the design and specifications of the Unit without prior notification. Some features or accessories of the
Unit may not be available in certain markets or areas. Please check with your distributor.
Chamberlain service centre contact details
Australia
Phone toll free 1800 638 234
Fax toll free 1800 888 121
Chamberlain Australia Pty. Ltd.
PO BOX 1446
Lane Cove NSW 1595
Website: gomerlin.com.au
New Zealand
Auckland phone 09 477 2823
Phone toll free 0800 653 667
Fax toll free 0800 653 663
Website: gomerlin.co.nz
Email: [email protected]
TM Trademark of The Chamberlain Group, Inc.
® Registered Trademark of The Chamberlain Group, Inc.
© 2013, The Chamberlain Group Inc.
advertisement
Key Features
- Automatic door operation: The opener automatically opens and closes your garage door with the touch of a button.
- Safety reverse system: The opener reverses the door's motion if it encounters an obstacle, preventing accidents.
- Wireless control: Operate your garage door from anywhere within range using the included remote control.
- Timer to close: Set a timer to automatically close your garage door after a specific time, providing peace of mind.
- Partial opening feature: Open the garage door partially for ventilation or to allow pedestrian access.
- The Protector System: Protects the opener and door from damage caused by excessive force.
- Manual release: Allows you to open the garage door manually in case of power outages or emergencies.
- Wireless wall button: Control the garage door from inside your home with the included wireless wall button.
Frequently Answers and Questions
How do I install the Merlin PowerAce MT60EVO?
Can I operate the garage door manually?
What is the Protector System?
How do I program the remote control?
Related manuals
advertisement
Table of contents
- 2 SAFETY INSTRUCTIONS
- 3 BEFORE YOU BEGIN
- 3 DOOR TYPES
- 4 CARTON INVENTORY
- 4 RAIL SIZES
- 5 TOOLS REQUIRED
- 5 HARDWARE PROVIDED
- 5 COMPLETED INSTALLATION
- 6 CONTROL PANEL
- 7 ASSEMBLY
- 8 INSTALLATION
- 12 ADJUSTMENT
- 14 SYSTEM (OPTIONAL)
- 15 BUTTON
- 15 TIMER TO CLOSE
- 16 INSTALL WARNING LABELS
- 16 PARTIAL OPENING FEATURE
- 17 WIRELESS PROGRAMMING
- 18 USING YOUR OPENER
- 18 CARE OF YOUR OPENER
- 18 REMOTE
- 19 ACCESSORIES
- 19 REPLACEMENT PARTS
- 21 TROUBLESHOOTING
- 23 SPECIFICATIONS
- 24 WARRANTY