ESIM252
ESIM252
GSM CONTROL SYSTEM
User Manual v2.1
Valid for ESIM252 v21.04.00 and up
SAFETY INSTRUCTIONS
Please read and follow these safety guidelines to safeguard yourself and others:
• GSM control system ESIM252 (later referred to as “the system” or “ the device”) contains a built-in radio transceiver operating in GSM
850/900/1800/1900 MHz bands.
• DO NOT use the system where it can cause potential danger and interfere with other devices – such as medical devices.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impact.
• DO NOT attempt to repair the system yourself – any repairs must be carried out by fully qualified personnel only.
Disconnect the mains power before installing. Never install or carry out maintenance during stormy weather. The electric
socket that powers the system must be easily accessible.
Please use the 10-24V 50Hz ~200mA AC or 10-24V
200mA DC power supply unit
that meets the EN 60950-1 standard. Any additional device you connect to the system,
such as a computer, must also be powered by an EN 60950-1 approved supply. When connecting the power supply to the system, switching the polarity terminal places does not
have any affect.
Phase
Null
PE
AC/DC
AC 230V
50 Hz/DC 24V
ESIM252
USB cable
External power supply can be connected to AC mains only inside installation room with automatic 2-pole circuit breaker capable of disconnecting circuit in the event of short circuit or over-current condition. Open circuit breaker must have a gap between connections of more than 3mm (0.12in) and the disconnection current 5A.
To switch the system off, unplug the external electric power supply from or any other linked device that the system is powered
from
A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (fuse
F1 model – MINISMDC050F 0.5A).
The WEEE (Waste Electrical and Electronic Equipment) symbol on this product (see left) means it must not be disposed of in
household waste. To prevent possible harm to human health and/or the environment, you must dispose of this product in an
approved and environmentally safe recycling facility. For further information contact your system supplier, or your local waste
authority.
2
EN
ESIM252 User Manual v2.1
CONTENTS
1. GENERAL INFORMATION..........................................................................................................................................................5
2. TECHNICAL SPECIFICATIONS....................................................................................................................................................5
2.1. Electrical and Mechanical Characteristics...................................................................................................................................................... 5
2.2. Main Unit, LED Indicator and Connector Functionality................................................................................................................................6
2.3. Wiring Diagram................................................................................................................................................................................................... 7
3.INSTALLATION..........................................................................................................................................................................8
4. GENERAL OPERATIONAL DESCRIPTION...................................................................................................................................9
5. CONFIGURATION METHODS.....................................................................................................................................................9
5.1. SMS Text Messages............................................................................................................................................................................................9
5.2. ELDES Configuration Tool.................................................................................................................................................................................9
6. SYSTEM LANGUAGE................................................................................................................................................................10
7. SMS PASSWORD......................................................................................................................................................................10
8. USER PHONE NUMBERS......................................................................................................................................................... 11
8.1. System Control from any Phone Number.....................................................................................................................................................12
9. DATE AND TIME.......................................................................................................................................................................13
10.INPUTS....................................................................................................................................................................................13
10.1. Pulse Counter....................................................................................................................................................................................................14
10.2. Disabling and Enabling Inputs........................................................................................................................................................................14
11. ALARM/RESTORE NOTIFICATIONS.........................................................................................................................................16
11.1. Enabling and Disabling Alarm/Restore Notification Delivery to All Listed Users .................................................................................19
12. AUDIO FILES........................................................................................................................................................................... 20
13.OUTPUTS............................................................................................................................................................................... 20
13.1. Output Names.................................................................................................................................................................................................. 20
13.2. Output Control by Free of Charge Phone Call..............................................................................................................................................21
13.3. Control by SMS Text Message........................................................................................................................................................................ 24
13.4. Automatic Output Control.............................................................................................................................................................................. 26
14. SYSTEM INFORMATION. INFO SMS........................................................................................................................................ 29
14.1. Periodic Info SMS............................................................................................................................................................................................. 29
15. SYSTEM NOTIFICATIONS....................................................................................................................................................... 30
15.1. SMSC (Short Message Service Center) Phone Number............................................................................................................................. 30
16. EVENT LOG..............................................................................................................................................................................31
17. REMOTE LISTENING................................................................................................................................................................32
18. GPRS NETWORK SETTINGS....................................................................................................................................................32
19. MONITORING STATION............................................................................................................................................................33
19.1. Data Messages - Events..................................................................................................................................................................................33
19.2.Communication.................................................................................................................................................................................................33
20. PROJECT EXAMPLES AND CONFIGURATION...........................................................................................................................37
20.1. Using in Enterprises.........................................................................................................................................................................................37
20.2. Using in a Private House................................................................................................................................................................................ 41
20.3. Using with Heating System and Flood Detector........................................................................................................................................ 43
20.4. Using for Breakdown Reports....................................................................................................................................................................... 45
21. TECHNICAL SUPPORT............................................................................................................................................................ 48
21.1.Troubleshooting.............................................................................................................................................................................................. 48
21.2. Restoring Default Parameters...................................................................................................................................................................... 48
21.3. Updating the Firmware via USB Cable......................................................................................................................................................... 48
21.4. Updating the Firmware via GPRS Connection Remotely.......................................................................................................................... 49
22. RELATED PRODUCTS............................................................................................................................................................. 50
ESIM252 User Manual v2.1
EN
3
Limited Liability
The buyer agrees that the system will reduce the risk of fire, theft, burglary or other danger but that it does not guarantee against the occurrence of such events. “ELDES UAB” will not take any responsibility for the loss of personal effects, property or revenue whilst using the
system. The liability of “ELDES UAB” is limited to the value of the system purchased. “ELDES UAB” is not affiliated with any mobile/wireless/
cellular provider and is therefore not responsible for the quality of such services.
Manufacturer Warranty
The system carries a 24-month manufacturer warranty from “ELDES UAB”. The warranty begins the day the system is purchased by the
user and the receipt must be retained as proof of purchase date. The warranty remains valid only if the system is used as intended, following all guidelines outlined in this manual and in accordance with the operating conditions specified. The warranty is void if the system
has been exposed to mechanical impact, chemicals, high humidity, fluids, corrosive and hazardous environments or force majeure factors.
Dear Customer,
Thank you for choosing to purchase the GSM control system ESIM252. Your thoughtful decision will ensure reliable solution for many
years as all ELDES products are manufactured to meet the highest standards.
We are confident that you will be completely satisfied with your product. However, in the unlikely event that you do experience a problem, please contact the dealer from whom you made your purchase.
UAB ELDES
www.eldes.lt
CONTENTS OF PACK
Item Quantity
1. ESIM252.................................................... 1
2. User manual............................................. 1
3. GSM/GPRS antenna................................ 1
4. Plastic standoffs..................................... 4
Not included:
• SIM card – we recommend you get a contract SIM, not Pay As You Go.
• miniUSB cable – can be obtained from your local distributor.
• Microphone – can be obtained from your local distributor.
Copyright © “ELDES UAB”, 2015. All rights reserved
It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a
warning. Hereby, “ELDES UAB” declares that the GSM control system ESIM252 is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt.
4
EN
ESIM252 User Manual v2.1
1.GENERAL INFORMATION
ESIM252 is a micro-controller based device intended to receive alarm/restore events by SMS text message or phone call and control an
electrical appliance via the GSM network.
Examples of using the system:
•
•
•
•
•
•
Access control.
Gate control of private houses.
Notification of system events, such as arming/disarming, alarm/restore from non-GSM alarm system.
Non-GSM alarm system arming/disarming by SMS text message.
Any electrical appliance control: lighting, watering, heating etc.
Remote reboot of the “frozen” systems, such as computer network or a server.
Main features:
• 5 inputs with customizable alarm/restore texts.
• Up to 5 user phone numbers for system configuration by SMS text messages, acceptance of input alarm/restore SMS text messages and
phone calls, output control by SMS text message and free of charge phone call.
• 2 relay outputs for electrical appliance control or non-GSM alarm system arming/disarming (key-switch).
• Manual output control by free of charge phone call.
• Automatic output control in accordance with the scheduled time.
• Up to 10 audio messages for input alarm/restore notification.
• Event log of 500 events.
• Periodic self-test notification by SMS text message to user phone number.
2.TECHNICAL SPECIFICATIONS
2.1. Electrical and Mechanical Characteristics
Supply voltage...........................................................................................10-24V 50Hz ~ 200mA max / 10-24V
200mA max
Current used in idle state.........................................................................Up to 50mA
GSM modem frequency............................................................................850/900/1800/1900 MHz
Number of outputs...................................................................................2
Output type...............................................................................................Relay; NO (normally-open)
Maximum commuting output values.....................................................24V 50Hz ~ 0,5A / 24V
1A
Number of “low” level (negative) inputs...............................................4
Number of “high” level (positive) inputs...............................................1
“Low” level (negative) input value range..............................................0... 16V
-0.8... -0.4mA
“High” level (positive) input value range..............................................5... 50V
0.17 .... 1.7mA
“Low” level (negative) and “high” level (positive)................................NO (normally-open) / NC (normally-closed)
input connection type
Dimensions................................................................................................87x107x29mm (3.43x4.21x1.14in)
Operating temperature range................................................................-20…+55 °C (-4... +131°F )
Humidity.....................................................................................................0-90% RH @ 0... +40°C (0-90% RH @ +32... +104°F) (non-condensing)
ESIM252 User Manual v2.1
EN
5
2.2. Main Unit, LED Indicator and Connector Functionality
1
USB
ANT
G SM
MO DE M
SIM CARD
SIM STAT
NETW
MIC
DEF
F1
AC/DC RELAY1 RELAY2 COM Z5 Z4 Z3 Z2 Z1
Main Unit Functionality
Connector Functionality
ANT
GSM/GPRS antenna SMA type connector
AC/DC
Power supply terminals
USB
Mini USB port
RELAY1
ESIM252 output C1 terminal
SIM CARD
SIM card slot / holder
RELAY2
ESIM252 output C2 terminal
GSM MODEM
GSM network 850/900/1800/1900 MHz
modem
COM
Common terminal
Z5
“Low” level (negative) input terminal
Z4
“Low” level (negative) input terminal
Z3
“Low” level (negative) input terminal
Z2
“High” level (positive) input terminal
Z1
“Low” level (negative) input terminal
MIC
Microphone connector
SIM STAT
Red light-emitting diode indicating SIM
card status
NETW
Green light-emitting diode indicating GSM
signal strength
DEF
Pins for restoring default settings
F1
0.5A fuse
LED Indicator Functionality
SIM STAT indication
SIM card status
NETW indication
GSM signal strength
OFF
No mains power / Successfully
connected to GSM network
OFF
No GSM signal
Flashing every 1 sec.
Poor
Steady ON
6
EN
SIM card is attempting to connect
to the GSM network / SIM card is
not present / PIN code enabled
Flashing 3 times per Medium
sec.
Steady ON
Good
ESIM252 User Manual v2.1
2.3. Wiring Diagram
ESIM252
2
AC/DC RELAY COM Z5 Z4 Z3 Z2 Z1
POWER
SUPPLY
+
-
ELECTRICAL APPLIANCE
ESIM252 User Manual v2.1
EN
7
3.INSTALLATION
• The system should be installed indoors, in stationary environment ONLY.
• For the connection of input/output terminals, use 0.50 mm2 (0.02in2) thread unshielded cable of up to 100m (328.08ft) length.
1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for more details).
2. Connect the GSM/GPRS antenna. Based on the type of the GSM/GPRS antenna supplied with ESIM252 unit, follow the recommendations
for the antenna installation:
Never install in the following
locations:
3
• inside the metal cabinet
GSM/GPRS
antena
• closer than 20cm (7.87in)
from the metal surface
and/or power lines
3. Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps.
4. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM252 system.
4
5
5. Ower up the system and wait until indicator SIM STAT lights up indicating SIM card status.
6. Once the indicator SIM STAT lights OFF, the illuminated indicator NETW lights up indicating that the system has successfully connected
to the GSM network. To find the strongest GSM signal, position the GSM/GPRS antenna and follow the indications provided by NETW
indicator (see 2.2. Main Unit, LED Indicator & Connector Functionality for more details).
7. Change the system language if necessary (see 6. SYSTEM LANGUAGE for more details).
8. Change the default SMS password (see 7. SMS PASSWORD for more details).
9. Set the phone number for User 1 (see 8. USER PHONE NUMBERS for more details).
10.Set system date and time (see 9. DATE AND TIME for more details).
11.Once the system is fully configured, it is ready for use. However, if you fail to receive a reply by SMS text message from the system,
please check the SMSC (Short Message Service Center) phone number. For more details regarding the SMS center phone number, please
refer to 15.1. SMSC (Short Message Service Center) Phone Number.
ATTENTION: The system is NOT compatible with pure 3G SIM cards. Only 2G/GSM SIM cards and 3G SIM cards with 2G/GSM profile
enabled are supported. For more details, please contact your GSM operator.
ATTENTION: We also recommend you to disable call forwarding, voice mail/text message reports on missed/busy calls (“call
catcher”) and similar services that might cause incorrect system operation. Please contact your GSM operator for more details on these
services and how to disable them.
NOTE: For maximum system reliability we recommend you do NOT use a Pay As You Go SIM card. Otherwise, in the event of insufficient
credit balance on the SIM card, the system would fail to make a phone call or send SMS text messages.
NOTE: We advise you to choose the same GSM SIM provider for your system as for your mobile phone. This will ensure the fastest, most
reliable SMS text message delivery service and phone call connection.
NOTE: The system is NOT compatible with pure 3G SIM cards. Only 2G/GSM SIM cards and 3G SIM cards with 2G/GSM profile enabled are
supported. For more details, please contact your GSM operator.
8
EN
ESIM252 User Manual v2.1
4.GENERAL OPERATIONAL DESCRIPTION
GSM control system ESIM252 uses the GSM network for event transmission by SMS text message. When one of the 5 available listed numbers dials the system, it answers the call and the user can listen to a pre-recorded audio message and hear what is going on in the premises
once the audio message is over. The remote listening function operates only when a microphone is connected. When the “conversation” is
over, the user The system will ignore SMS requests and phone calls coming from non-listed phone numbers.
The system has 5 digital inputs (normally closed or normally open) for alarm system’s PGM output or detection device connection, such as
magnetic door contact. By connecting the input to the non-GSM alarm system’s PGM output, the user will be able to receive an SMS text
message or phone call regarding system alarm/restore, arming/disarming and other events depending on the alarm system configuration.
In addition to being informed by SMS text message or phone call regarding alarm and restore events of the inputs, the users can control
one electrical appliance by connecting it to the relay outputs. For example, users can turn ON or OFF the heating, lighting, lift the gates,
blinds etc. The output can also be used for arming/disarming by connecting it to one of the alarm system zones configured as a key-switch.
5.CONFIGURATION METHODS
5.1. SMS Text Messages
In this user manual the underscore character ”_” represents one space character. Every underscore character must be replaced
by a single space character. There must be no spaces or other unnecessary characters at the beginning and at the end of the
SMS text message.
SMS
In order to configure and control the system by SMS text message, send the text command to the ESIM252 system phone
number from one of the listed user phone numbers. The structure of SMS text message consists of 4-digit SMS password (the
default SMS password is 0000 – four zeros), the parameter and value. For some parameters the value does not apply e. g.
STATUS. The variables are indicated in lower-case letters, while a valid parameter value range is indicated in brackets.
5.2. ELDES Configuration Tool
Software ELDES Configuration Tool is intended for ESIM252 GSM control system configuration locally via USB port or remotely via GPRS
network connection. This software simplifies system configuration process by allowing to use a personal computer in the process. Before
starting to use ELDES Configuration Tool software, please read the user guide provided in the software’s HELP section.
ELDES Configuration Tool is freeware and can be downloaded from at: www.eldes.lt
NOTE: ELDES Configuration Tool software is secured with SMS password. The default SMS password is 0000 (see 7. SMS PASSWORD).
5.2.1.Remote Connection
ATTENTION: The system will NOT send any data to the monitoring station while remote configuration is in progress. However, during the remote configuration session the data messages will be queued up and transmitted to the monitoring station after the remote
configuration session is over.
ELDES Configuration Tool software provides remote system configuration ability via Internet using one of the following methods:
• ELDES proxy server (recommended). The connection can be established on the system via GPRS network.
• Running TCP/IP server on ELDES Configuration Tool (advanced). The connection can be established on the system via GPRS network.
In order to start using the remote configuration feature, please run the step-by-step wizard and follow the steps provided in the start page
of ELDES Configuration Tool software. Please, note that it will be necessary to send an SMS text message to the system’s phone number
in order to initiate the remote connection. By following the steps you will be instructed on what text must be sent to the system’s phone
number in such case.
5.2.2. Ending the Remote Connection Session
After the system configuration is complete, use one of the following methods to end the configuration process:
• Click Disconnect or Stop button and close ELDES Configuration Tool software;
• The session will automatically expire in 20 minutes. Before the last 5 minutes, the software will offer the user to extend the session for
another 20 minutes.
• Alternatively, the connection with the server can be terminated at any time by sending an SMS text message.
Terminate the
connection
SMS text message content:
ssss_ENDCONFIG
Value: ssss – 4-digit SMS password.
Example: 1111_ENDCONFIG
Once the session is expired or terminated, the system will reply with an SMS text message confirming the end of the session.
ESIM252 User Manual v2.1
EN
9
6.SYSTEM LANGUAGE
The system comes equipped with a multiple languages for communication with the user by SMS text messages. The default system language depends on the firmware, which is based on the customer’s location.
List of currently available system languages:
• English
• Lithuanian
• Slovak
Set system language
SMS
Config
Tool
SMS text message content:
LN
Value: LN – language index; range – [EN – English,, LT – Lithuanian, SK – Slovak].
Example: LT
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: To change the language once the system has already been configured, you need to reset the device to the default configuration.
For more details on how to do this, please refer to 21.2. Restoring Default Parameters.
7.SMS PASSWORD
For security reasons, the system uses the following type of password:
SMS password – 4-digit password used for system configuration and control from user phone number by SMS text messages and logging
in to ELDES Configuration Tool software. By default, SMS password is 0000, which MUST be changed!
Set SMS password
SMS
Config
Tool
SMS text message content:
wwww_PSW_ssss
Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range –
[0001... 9999].
Example: 0000_PSW_1111
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: The system rejects the SMS text messages containing wrong SMS password even from a listed user phone number.
10
EN
ESIM252 User Manual v2.1
8.USER PHONE NUMBERS
The system supports up to 5 user phone numbers identified as User 1 through 5. When the phone number is set, the user will be able to
configure and control the system by SMS text messages as well as by free of charge phone call and receive the input alarm/restore SMS text
messages and/or phone calls from the system (see 11. ALARM/RESTORE NOTIFICATIONS).
By default, the system ignores any incoming calls and SMS text messages from a non-listed phone number as well as it rejects the SMS text
messages containing wrong SMS password even from a listed user phone number. For more details on how to enable output control from a
non-listed phone number, please refer to 8.1. System Control from any Phone Number.
To set User 1 phone number is mandatory, while the other 4 are optional. The supported phone number format is the following:
• International (w/o plus) – The phone numbers must be entered starting with an international country code in the following format:
[international code][area code][local number], example for UK: 441709xxxxxxx.
Set user phone
number
SMS
Config
Tool
View user phone
number
SMS
Config
Tool
Delete user phone
number
SMS
Config
Tool
SMS text message content:
ssss_NRu:ttteeellnnuumm
Value: ssss – 4-digit SMS password; u – user phone number slot, range – [1... 5]; ttteeellnnuumm – up to 15 digits administrator phone number.
Example: 1111_NR1:441709xxxxxxx
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_HELPNR
Value: ssss – 4-digit SMS password.
Example: 1111_HELPNR
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_NRu:DEL
Value: ssss – 4-digit SMS password; u – user phone number slot, range – [1... 5].
Example: 1111_NR2:DEL
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: The system rejects the SMS text messages containing wrong SMS password even from a listed user phone number.
ATTENTION: Once User 1 phone number is set, the system will restrict only to modify it
ATTENTION: Multiple user phone numbers can be set by a single SMS text message, Example: 1111_NR1:441709xxxxxx1_
NR5:441709xxxxxx2_NR2:441709xxxxxx3_NR3: 441709xxxxxx4
NOTE: Multiple user phone numbers can be deleted by a single SMS text message, Example: 1111_NR2:DEL_NR4:DEL_ NR3:DEL
ESIM252 User Manual v2.1
EN
11
8.1. System Control from any Phone Number
By default, the system ignores any incoming calls and SMS text messages from a non-listed phone number as well as it rejects the SMS text
messages containing wrong SMS password even from a listed user phone number. To permit/deny incoming phone calls and SMS text messages that contain a valid SMS password from any phone number, please refer to the following configuration methods.
Enable system control
from any phone
number
SMS
Config
Tool
Disable system
control from any
phone number
SMS
Config
Tool
12
EN
SMS text message content:
ssss_STR:ON
Value: ssss – 4-digit SMS password.
Example: 1111_STR:ON
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_STR:OFF
Value: ssss – 4-digit SMS password.
Example: 1111_STR:OFF
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
9.DATE AND TIME
The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and
running, the user must set the correct date and time, otherwise the system will not operate properly. By default, after shutting down and
starting up the system, the date and time must be set again.
Set date and time
SMS
Config
Tool
SMS text message content:
ssss_yyyy.mt.dd_hr:mn
Value: ssss – 4-digit SMS password; yyyy – year; mt – month, range – [01... 12]; dd – day, range
– [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59].
Example: 1111_2014.03.16_14:33
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: When the system is connected to the monitoring station via GPRS network connection (see 19. MONITORING STATION), the
date and time will be automatically synchronized with the monitoring station or Smart Security server upon the system startup.
10.INPUTS
The system comes equipped with 5 inputs identified as Z1 through Z5. Normally, the inputs are used for PGM output connection of nonGSM alarm system, motion detectors, door contacts and other passive or active digital level sensors. Once a detection device is triggered,
the system will send a notification to the user phone number. For more details, please refer to 11. ALARM/RESTORE NOTIFICATIONS.
Each input’s sensitivity level can be customized by a delay time (by default – 600 milliseconds). If an input is left triggered until the delay
time expires, the input is considered violated.
Set input delay
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:Zn:DVin-delay
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; in-delay – input delay,
range – [100... 10000] milliseconds.
Example: 1111_SMSEXTRA:Z3:DV800
This operation may be carried out from the PC using the ELDES Configuration Tool software.
By default, all system inputs are set as NO (normally-open). To change the input connection type to NC (normally closed)/NO (normally
open), please refer to the following configuration methods.
Set input as NC
(normally closed)
SMS
Config
Tool
Set input as NO
(normally open)
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:Zn:LI1
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_SMSEXTRA:Z4:LI1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:LI0
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_SMSEXTRA:Z2:LI0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
The system allows to view the current input state by the following configuration method.
ESIM252 User Manual v2.1
EN
13
View input state
SMS
Config
Tool
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
This operation may be carried out from the PC using the ELDES Configuration Tool software.
10.1. Pulse Counter
The system comes equipped with input pulse counter feature. The feature determines the number of input violation events, known as
pulses, that result in input alarm SMS text message delivery and/or phone call to the listed user phone number once the number of the set
up pulses is achieved. The time-frame between the pulses is unlimited.
By default, the pulse counter feature is disabled and the number of pulses is not set. To enable/disable it and set the number of pulses,
please refer to the following configuration methods:
Enable pulse counter
SMS
Config
Tool
Set number of pulses
SMS
Config
Tool
Disable pulse counter
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:Zn:IE1
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_SMSEXTRA:Z2:IE1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:ICnum-pulse
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; num-pulse – number of
pulses, range - [0... 4294967295].
Example: 1111_SMSEXTRA:Z5:IC562
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:IE0
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_SMSEXTRA:Z1:IE0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Once the pulse counter feature is in use, the input restore notifications regarding a certrain input will no longer be delivered to
the listed user phone number, even if enabled.
10.2.Disabling and Enabling Inputs
By default, all inputs are enabled. Once disabled, input alarm/resetore event will no longer be followed by an SMS text message and/or
phone call. To disable/enable an individual input, please refer to the following configuration methods.
Disable input
SMS
Config
Tool
14
EN
SMS text message content:
ssss_Zn:OFF
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_Z1:OFF
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
Enable input
SMS
Config
Tool
View input status
SMS
Config
Tool
SMS text message content:
ssss_Zn:ON
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5].
Example: 1111_Z5:ON
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_STATUS
Value: ssss – 4-digit SMS password.
Example: 1111_STATUS
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Multiple inputs can be managed by a single SMS text message, Example: 1111_Z1:OFF ;Z3:ON;Z5:OFF;
ESIM252 User Manual v2.1
EN
15
11.ALARM/RESTORE NOTIFICATIONS
In the event of input alarm or restore, the system can notify the listed user phone number by the following methods that can be used
individually or simultaneously:
•
SMS text message.
•
Phone call.
By default, in the event of input alarm, the system will follow this pattern:
SMS
a) The system attempts to send an SMS text message containing input alarm text to the first listed user phone number only.
b) If the user phone number is unavailable and the system fails to receive the SMS delivery report within 45 seconds, it will
attempt to send the SMS text message to the next listed user phone number. The system may fail to deliver the SMS text
message to the listed user phone number due to the following reasons:
• user’s mobile phone has been switched off.
• user’s mobile phone has been out of GSM signal coverage.
c) The system will continue sending the SMS text message to the next listed user phone numbers in the priority order until
one is available (to change this algorithm, please refer to 11.1. Enabling and Disabling Alarm/Restore Notification
Delivery to All Listed Users).
d) The system sends the SMS text message only once and will not return to the first user phone number if the last one was
unavailable, therefore if the system ends up with all unsuccessful attempts, it will delete the queued up event from the
memory and it will no longer attempt to send it by SMS text message.
By default, input restore notification by SMS text message is disabled. Once enabled, the system will follow the SMS text message delivery pattern identically as for input alarm event.
To manage input alarm and restore SMS text messages, please refer to the following configuration methods
Disable input alarm
notification by SMS
SMS
Config
Tool
Enable input alarm
notification by SMS
SMS
Config
Tool
Set input alarm text
SMS
Config
Tool
16
EN
SMS text message content:
ssss_SMSEXTRA:Zn:SCu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z4:SC4
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:SSu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z3:SS1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_Zn:in-alarm-text
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; in-alarm-text – up to 24
characters input alarm text.
Example: 1111_Z2:Alarm Input2
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
Enable input restore
notification by SMS
SMS
Config
Tool
Disable input restore
notification by SMS
SMS
Config
Tool
Set input restore text
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:Zn:SEu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z1:SE5
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:SDu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z2:SD1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_ZRn:in-restore-text
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; in-restore-text – up to
24 characters input alarm text.
Example: 1111_ZR3:Restore Input3
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: Colon and semicolon characters are NOT allowed in the input alarm/restore notification texts.
NOTE: Multiple alarm/restore texts can be managed by a single SMS text message, Example: 1111_Z2:Alarm In2;ZR4:Restore In4;
NOTE: Multiple users can be managed by a single SMS text message; Example: 1111_SMSEXTRA:Z2:SE135
The system comes equipped with ringing the listed user phone number (by default – disabled) in the event of input alarm/
restore. By default, in the event of input alarm, the system will follow this pattern:
a) The system attempts to ring the first listed user phone number.
b) When the call is answered, the system will play the audio file that can be listened to on the user’s mobile phone. This feature
will be available only if an audio file is recorded and assigned to the input alarm event (see 12. AUDIO FILES).
c) When the audio record has played, the user will be able to listen on the mobile phone to what is happening in the area, surrounding the alarm system. This feature will be available only if a microphone is connected to the system (see 17. REMOTE
LISTENING).
d) The system will dial the next listed user phone number if the previous user was unavailable due to the following reasons:
• mobile phone has been switched off.
• mobile phone has been out of GSM signal coverage.
• has provided “busy” signal.
• user did not answer the call after several rings, predetermined by the GSM operator.
e) The system will continue dialing the next listed user phone numbers in the priority order until one is available.
f) The system will dial the first user phone number again if the last one was unavailable thus carrying out the cycle 3 times in total. The
system will not dial the next listed user phone number if the previous one was available, but rejected the phone call (to change this
algorithm, please refer to 11.1. Enabling and Disabling Alarm/Restore Notification Delivery to All Listed Users).
By default, input restore notification by phone call is disabled. Once enabled, the system will follow the phone call delivery
pattern identically as for input alarm event.
To manage input alarm and restore phone calls, please refer to the following configuration methods
ESIM252 User Manual v2.1
EN
17
Disable input alarm
notification by call
SMS
Config
Tool
Enable input alarm
notification by call
SMS
Config
Tool
Enable input restore
notification by call
SMS
Config
Tool
Disable input restore
notification by call
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:Zn:CCu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z2:CC4
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:CSu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z2:CS1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:CEu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z5:CE1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:Zn:CDu
Value: ssss – 4-digit SMS password; n – input number, range – [1... 5]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:Z1:CD3
This operation may be carried out from the PC using the ELDES Configuration Tool software.
By default, the system dials the first available user in case of alarm. If the user did not answer the call or was unavailable, the system will
attempt to dial the next listed user phone number. However, if the phone call was answered or rejected by the user, the system will not dial
the next listed user phone number. To change the alarm/restore phone call algorithm, user can enable/disable the following parameter for
alarm/restore events:
NOTE: Multiple users can be managed by a single SMS text message; Example: 1111_SMSEXTRA:Z3:CD25
• Confirmation required when calling in case of alarm/restore – This parameter determines whether the answered call requires
a DTMF signal confirmation by pressing the [#] key on the mobile phone keypad or not. Once enabled, the system will dial every listed
user phone number that is enabled to receive an alarm/restore event from the system by phone call regardless of the fact that user was
unavailable, did not answer the call, rejected the call or answered the call, but did not confirm it by pressing the [#] key.
Enable/disable
confirmation request
for calls in case of
alarm/restore
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Confirmation required when calling in case of alarm/restore feature is supported by product s/n: 0010742 and up.
18
EN
ESIM252 User Manual v2.1
11.1. Enabling and Disabling Alarm/Restore Notification Delivery to All Listed Users
SMS
By default, the system sends SMS text message to the first available user in case of alarm. If the system did not receive the
SMS delivery report within 45 seconds, it will attempt to send the SMS text message to the next listed user phone number.
To change the SMS text message delivery algorithm, user can enable/disable the following parameters for alarm events:
• Send alarm/restore SMS to all users simultaneously – This parameter determines whether to ignore the SMS delivery
report or not. Once enabled, the system will attempt to send the SMS text message to every listed user phone number that
is enabled to receive an alarm/restore event from the system by SMS text message. In addition, this parameter overrides the
SMS delivery report parameter regardless of the SMS delivery report parameter’s status (enabled/disabled).
• SMS ACK (delivery report) – This parameter determines whether to request for SMS delivery report or not. Once disabled,
the system will not verify the status of the SMS text message delivery and will attempt to deliver the SMS text message only
to the first listed user phone number regardless if the next listed user phone number (-s) is enabled to receive a certain event
by SMS text message or not.
Enable alarm/restore
SMS text message
delivery to all listed
users simultaneously
SMS
Config
Tool
Disable alarm/restore
SMS text message
delivery to all listed
users simultaneously
SMS
Config
Tool
SMS text message content:
ssss_SMSALL:ON
Value: ssss – 4-digit SMS password.
Example: 1111_SMSALL:ON
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSALL:OFF
Value: ssss – 4-digit SMS password.
Example: 1111_SMSALL:OFF
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: SMS ACK (delivery report) parameter applies to all SMS text messages delivered by the system.
By default, the system dials the first available user in case of alarm. If the user did not answer the call or was unavailable, the
system will attempt to dial the next listed user phone number. However, if the phone call was answered or rejected by the user,
the system will not dial the next listed user phone number. To change the alarm/restore phone call algorithm, user can enable/
disable the following parameter for alarm/restore events:
• Call to all users simultaneously in case of alarm/restore – This parameter determines whether to ignore the answered or rejected calls by the previous user in case of alarm/restore or not. Once enabled, the system will attempt to dial
every listed user phone number that is enabled to receive an alarm/restore event from the system by phone call.
Enable alarm/restore
phone call to all
listed users
SMS
Config
Tool
Disable alarm/restore
phone call to all
listed users
SMS
Config
Tool
ESIM252 User Manual v2.1
SMS text message content:
ssss_CALLALL:ON
Value: ssss – 4-digit SMS password.
Example: 1111_CALLALL:ON
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_CALLALL:OFF
Value: ssss – 4-digit SMS password.
Example: 1111_CALLALL:OFF
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
19
12.AUDIO FILES
The system comes equipped with a feature allowing to record up to 5 audio files of up to 15 seconds length using the microphone of the PC.
The recorded file can be assigned to the input alarm and/or restore event and be played when the alarm/restore is caused by input with an
audio file assigned. This feature will be available only if the system is pre-configured to dial a user phone number in the event of an input
alarm and/or restore and if the user answers the call. The supported audio file format is as follows:
• Max. number of audio files: up to 10 (5 for input alarm event and 5 for input restore event)
• Max. audio length: up to 15 seconds
• File format: .wav
• Specifications: 8,000 kHz; 8 Bit; Mono
Record and manage
the audio files
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: It is highly recommended to use ELDES Configuration Tool software’s built-in sound recorder to record an audio file.
13.OUTPUTS
ESIM252 comes equipped with 2 built-in outputs for electrical appliance or non-GSM alarm panel’s zone connection. Normally, the output
can be used to open/close garage doors, activate lights, heating, watering as well as a key-switch for non-GSM alarm system arming/disarming. When the output turns ON, the system triggers any device or relay connected to it.
The system supports the following output control methods:
• Free of charge phone call from the user phone number (see 13.2. Output Control by Free of Charge Phone Call).
• SMS text message from the user phone number (see 13.3. Output Control by SMS Text Message).
• Automatically in accordance with the scheduled time (see 13.4. Automatic Output Control).
View output state
SMS
Config
Tool
SMS text message content:
ssss_STATUS
Value: ssss – 4-digit SMS password.
Example: 1111_STATUS
This operation may be carried out from the PC using the ELDES Configuration Tool software.
13.1. Output Names
The outputs have a name that can be customized. Typically, the name specifies a device type connected to a determined output, for ex­
ample: Pump. The name can be used instead of output number when controlling the output by SMS text message. In addition, the output
name is always included in output control confirmation SMS text message (if enabled).
By default, the output names are as follows: C1 – Controll1, C2 – Controll2
Set output name
SMS
Config
Tool
20
EN
SMS text message content:
ssss_Co:out-name
Value: ssss – 4-digit SMS password; o – output number, range [1 – output C1; 2 – output C2];
out-name – up to 11 characters output name.
Example: 1111_C2:Boiler
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
View output name
SMS
Config
Tool
SMS text message content:
ssss_STATUS
Value: ssss – 4-digit SMS password.
Example: 1111_STATUS
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: Space, colon, semi-colon characters, parameter names and/or values, such as PSW, STATUS, ON, OFF etc. are NOT allowed
in output names.
13.2. Output Control by Free of Charge Phone Call
Once enabled, the specified user can control the electrical appliance connected to the system’s output by dialling the system’s
phone number from any available user phone number (see 8. USER PHONE NUMBERS for phone number management). The
phone call is free charge as the system rejects it and turns ON/OFF the output (-s) resulting in the electrical appliance turning
ON or OFF, depending on the current output state. The output can also be used for a key switch feature allowing to arm/disarm
a non-GSM alarm panel. If there is more than one preset caller dialing to the system at the same time, the system will accept the
incoming call from the caller who was the first to dial while other caller (-s) will be ignored.
The system supports the following output control actions upon free of charge phone call:
•
Turn ON – Turns ON the output and keeps it in this state for a set up period of time.
•
Turn OFF – Turns OFF the output and keeps it in this state for a set up period of time.
•
Toggle – Turns ON the output and keeps it in this state until the phone call reoccurs. The set up period of time has no effect on
this action.
Enable output control
by free of charge phone
call for a certain user
SMS
Config
Tool
Disable output control
by free of charge phone
call for a certain user
SMS
Config
Tool
Set output action
as Turn ON
SMS
Config
Tool
ESIM252 User Manual v2.1
SMS text message content:
ssss_SMSEXTRA:COCo:CEu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC1:CE5
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:CDu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC2:CD2
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:MSu1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC2:MS41
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
21
Set output action as
Turn OFF
SMS
Config
Tool
Set output control
duration for Turn ON/
Turn OFF action
SMS
Config
Tool
Set output action
as Toggle
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:COCo:MSu0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC1:MS20
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:MSuThr.mn.sc
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_SMSEXTRA:COC2:MS5T05.12.30
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:MSu2
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC1:MS42
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Multiple users can be managed by a single SMS text message Example: 1111_SMSEXTRA:COC2:CE245
13.2.1. Confirmation for Output Control via Call
After turning the output ON or OFF, the system can send a confirmation reply by an SMS text message, containing the output name (see
13.1. Output Names), to the user phone number that has initiated the output control action by free of charge phone call. In addition, the
system can make a phone call confirming that the output control action has been successfully carried out. Once enabled, output ON action
will be followed by a 2-second (by default) ring, while the OFF action will be indicated by a 8-second (by default) ring to the user phone
number that has initiated the output control action by call.
By default, the output control confirmations are disabled. To manage the output control via call confirmations, please refer to the following
configuration methods.
Enable output control
via call confirmation
by SMS
SMS
Config
Tool
Disable output control
via call confirmation
by SMS
SMS
Config
Tool
22
EN
SMS text message content:
ssss_SMSEXTRA:COCo:SSu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC2:SS2
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:SCu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC2:SC4
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
Enable output control
via call confirmation by
call back
SMS
Config
Tool
Disable output control
via call confirmation by
call back
SMS
Config
Tool
Set call back duration
for output ON action
SMS
Config
Tool
Set call back duration
for output OFF action
SMS
Config
Tool
ESIM252 User Manual v2.1
SMS text message content:
ssss_SMSEXTRA:COCo:CSu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC1:CS3
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:CCu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:COC1:CC5
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:CTu1cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number slot, range – [1... 5]; cd – call back duration, range – [0... 60] seconds.
Example: 1111_SMSEXTRA:COC:CT4120
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:COCo:CTu0cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5]; cd – call back duration, range – [0... 60] seconds.
Example: 1111_SMSEXTRA:COC:CT2025
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
23
13.3. Control by SMS Text Message
To turn ON or turn OFF the output (-s), send the SMS text message from any of 5 available user phone numbers (see 8. USER
PHONE NUMBERS for phone number management). To instantly turn ON/OFF the output and set its state to ON/OFF when
the system starts-up, please refer to the following configuration methods.
SMS
Turn ON output/Set
output start-up state
as ON
SMS
Config
Tool
Turn OFF output/Set
output start-up state
as OFF
SMS
Config
Tool
SMS text message content:
ssss_Co:ON or ssss_out-name:ON
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; out-name – up to 11
characters output name.
Example: 1111_Lamp:ON
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_Co:OFF or ssss_out-name:OFF
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; out-name – up to 11
characters output name.
Example: 1111_C2:OFF
This operation may be carried out from the PC using the ELDES Configuration Tool software.
To turn ON/OFF the output (-s) for a determined time period (pulse), please refer to the following configuration methods.
Turn ON output for
time period
SMS
Config
Tool
Turn OFF output for
time period
SMS
Config
Tool
24
EN
SMS text message content:
ssss_Co:ON:hr.mn.sc or ssss_out-name:ON:hr.mn.sc
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; hr – hours, range –
[00... 23]; mn – minutes, range – [00... 59]; sc – seconds, range – [00... 59]; out-name – up to
11 characters output name.
Example: 1111_C2:ON:00.00.09
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_Co:OFF:hr.mn.sc or ssss_out-name:OFF:hr.mn.sc
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; hr – hours, range –
[00... 23]; mn – minutes, range – [00... 59]; sc – seconds, range – [00... 59]; out-name – up to
11 characters output name.
Example: 1111_C1:OFF:00.11.49
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
13.3.1. Confirmation for Output Control via SMS
By default, after turning the output ON or OFF, the system will send a confirmation reply by an SMS text message, containing the output
name (see 13.1. Output Names), to the user phone number that has initiated the output control action by SMS text message.
In addition, the system can make a phone call confirming that the output control action has been successfully carried out. Once enabled,
output ON action will be followed by a 2-second (by default) ring, while the OFF action will be indicated by a 8-second (by default) ring to
the user phone number that has initiated the output control action by SMS text message.
To manage the output control via SMS confirmations, please refer to the following configuration methods.
Disable output
control via SMS
confirmation by SMS
SMS
Config
Tool
Enable output control
via SMS confirmation
by SMS
SMS
Config
Tool
Enable output control
via SMS confirmation
by call back
SMS
Config
Tool
Disable output control
via SMS confirmation
by call back
SMS
Config
Tool
Set call back duration
for output ON action
SMS
Config
Tool
ESIM252 User Manual v2.1
SMS text message content:
ssss_SMSEXTRA:OCSo:SB0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCS2:SB0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCSo:SB1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCS1:SB1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCSo:CB1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCS2:CB1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCSo:CB0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCS2:CB0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCSo:CT1cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; cd – call back duration,
range – [0... 60] seconds.
Example: 1111_SMSEXTRA:OCS2:CT15
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
25
Set call back duration
for output OFF action
SMS
Config
Tool
SMS text message content:
ssss_SMSEXTRA:OCSo:CT0cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; cd – call back duration,
range – [0... 60] seconds.
Example: 1111_SMSEXTRA:OCS1:CT020
This operation may be carried out from the PC using the ELDES Configuration Tool software.
13.4.Automatic Output Control
ATTENTION: System date and time must be set, otherwise the system will NOT be able to control the output (-s) automatically. For
more details on how to set date and time, please refer to 9. DATE AND TIME.
The system comes equipped with an automatic output control in accordance with the scheduled time. When the scheduler is set up, the
output will automatically turn ON/OFF on based on the specified time set for a certain duration. Once set up, the scheduler will operate
once per day.
By default, the scheduler is not set up. To set up the scheduler and manage the output state, please refer to the following configuration
methods.
Set scheduler start time
SMS
Config
Tool
Set scheduler duration
SMS
Config
Tool
Set output state to ON
SMS
Config
Tool
Set output state to OFF
SMS
Config
Tool
26
EN
SMS text message content:
ssss_SMSEXTRA:OCTEo:WThr.mn
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; hr – hours, range –
[00... 23]; mn – minutes, range – [00... 59].
Example: 1111_SMSEXTRA:OCTE2:WT14.16
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:PThr.mn
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; hr – hours, range –
[00... 23]; mn – minutes, range – [00... 59].
Example: 1111_SMSEXTRA:OCTE1:PT00.15.10
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:ST1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE1:ST1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:ST0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE2:ST0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
13.4.1.Confirmation for Output Control using Scheduler
After turning the output ON or OFF, the system can send a confirmation reply by an SMS text message, containing the output name (see
13.1. Output Names), to the user phone number that is specified to receive it upon execution of the output control action by scheduled
time. In addition, the system can make a phone call confirming that the output control action has been successfully carried out. Once enabled, output ON action will be followed by a 2-second (by default) ring, while the OFF action will be indicated by a 8-second (by default) ring
to the user phone number that is specified to receive it upon execution of the output control action by scheduled time.
By default, the output control using scheduler confirmations are disabled. To manage the output control using scheduler confirmations,
please refer to the following configuration methods.
Select user phone
number for output
control confirmation
acceptance
SMS
Config
Tool
Disable output control
confirmation by SMS
text message for
scheduler start
SMS
Config
Tool
Enable output control
confirmation by SMS
text message for
scheduler start
SMS
Config
Tool
Disable output
control confirmation
by SMS text message
for scheduler end
SMS
Config
Tool
Enable output control
confirmation by SMS
text message for
scheduler end
SMS
Config
Tool
Enable output control
confirmation by call
back for scheduler start
SMS
Config
Tool
ESIM252 User Manual v2.1
SMS text message content:
ssss_SMSEXTRA:OCTEo:UCu
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; u – user phone number
slot, range – [1... 5].
Example: 1111_SMSEXTRA:OCTE1:UC2
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:SS0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE2:SS0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:SS1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE1:SS1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:SE0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE1:SE0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:SE1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE2:SE1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:CS1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE2:CS1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
27
Disable output control
confirmation by call
back for scheduler start
SMS
Config
Tool
Enable output control
confirmation by call
back for scheduler end
SMS
Config
Tool
Disable output control
confirmation by call
back for scheduler end
SMS
Config
Tool
Set call back duration
for output ON action
SMS
Config
Tool
Set call back duration
for output OFF action
SMS
Config
Tool
28
EN
SMS text message content:
ssss_SMSEXTRA:OCTEo:CS0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE1:CS0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:CE1
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE1:CE1
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:CE0
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2].
Example: 1111_SMSEXTRA:OCTE2:CE0
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:CT1cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; cd – call back duration,
range – [0... 60] seconds.
Example: 1111_SMSEXTRA:OCTE2:CT15
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SMSEXTRA:OCTEo:CT0cd
Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; cd – call back duration,
range – [0... 60] seconds.
Example: 1111_SMSEXTRA:OCTE1:CT020
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ESIM252 User Manual v2.1
14.SYSTEM INFORMATION. INFO SMS
The system supports an informational SMS text message identified as the Info SMS, which can be delivered upon request. Once requested,
the system will reply with Info SMS that provides the following:
• System date & time.
• GSM signal strength.
• State of inputs (OK/alarm).
Request system
information
SMS
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
14.1. Periodic Info SMS
By default, the system sends Info SMS to user phone number periodically once a day at 11:00 (frequency – 1 day; time – 11). The minimum
period is every 1 hour (frequency – 0 days; time – 1). Typically, this feature is used to verify the power supply and online status of the system.
To set a different frequency and time or disable periodic Info SMS, please refer to the following configuration methods.
Set periodic Info SMS
frequency and time
SMS
Config
Tool
Disable periodic
Info SMS
SMS
Config
Tool
SMS text message content:
ssss_INFO:fff.it
Value: ssss – 4-digit SMS password; fff – frequency, range – [00... 99] days; it – time, range
– [01... 23].
Example: 1111_INFO:3.15
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_INFO:00.00
Example: 1111_INFO:00.00
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: System date and time must be set, otherwise periodic Info SMS will be delivered incorrectly. For more details on how to
set date and time, please refer to 9. DATE AND TIME.
ESIM252 User Manual v2.1
EN
29
15.SYSTEM NOTIFICATIONS
By default in case of a certain event, the system attempts to send an SMS text message to the first listed user phone number only. If the
user phone number is unavailable and the system fails to receive the SMS delivery report within 45 seconds, it will attempt to send the SMS
text message to the next listed user phone number. The user phone number may be unavailable due to the following reasons:
• mobile phone was switched off.
• was out of GSM signal coverage.
The system will continue sending the SMS text message to the next listed user phone numbers in the priority order until one is available.
The system sends the SMS text message only once and will not return to the first user phone number if the last one was unavailable.
To change the SMS text message delivery algorithm, user can enable/disable the following parameter:
SMS ACK (delivery report) - This parameter determines whether to request for SMS delivery report or not. Once disabled, the system will
not verify the status of the SMS text message delivery and will attempt to deliver the SMS text message only to the first listed user phone
number regardless if the next listed user phone number (-s) is enabled to receive a certain event by SMS text message or not.
The following table provides the description of system notifications by SMS text message sent to the user phone number.
Seq. No.
Event
Description
1
System Startup
SMS text message sent to the user on system startup. For more details on how to manage this
notification, please refer to the configuraition methods below.
2
Input Alarm
SMS text message sent to the user in case input is violated. For more details on how to manage this
notification, please refer to 11. ALARM/RESTORE NOTIFICATIONS.
3
Input Restore
SMS text message sent to the user in case input is restored. For more details on how to manage this
notification, please refer to 11. ALARM/RESTORE NOTIFICATIONS.
4
Periodic Info
Status SMS text message sent to the user periodically by the set up hours. For more details on how to
manage this notification, please refer to 14. SYSTEM INFORMATION. INFO SMS.
By default, System Startup notification is enable. To disable/enable it , please refer to the following configuration method.
Manage System
Startup notification
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
15.1. SMSC (Short Message Service Center) Phone Number
An SMS center (SMSC) is a GSM network element, which routes SMS text messages to the destination recipient and stores the SMS text
message if the recipient is unavailable. Typically, the phone number of the SMS center is already stored in the SIM card provided by the
GSM operator. If the user fails to receive replies from the system, the SMS center phone number, provided by the GSM operator, must be
set manually.
Set SMSC phone
number
30
EN
SMS
SMS text message content:
ssss_SMS_+ttteeellnnuumm
Value: ssss – 4-digit SMS password; ttteeellnnuumm – up to 15 digits SMSC phone number.
Example: 1111_SMS_+4417031111111
ESIM252 User Manual v2.1
16.EVENT LOG
This feature allows to chronologically register up to 500 timestamped records regarding the following system events:
• Input alarm and restore events
• Output control by free of charge phone call and SMS text message events
• Automatic output control based on scheduler beginning.
• Automatic output control based on scheduler ending.
• Periodic info event
The event log is of LIFO (last in, first out) type that allows the system to automatically replace the oldest records with the the latest ones.
By default, event log is disabled. To enable/disable this feature, please refer to the following configuration methods.
Enable/disable
event log
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
To export the event log to .log file or clear it, please refer to the following configuration methods.
Export/clear
event log
ESIM252 User Manual v2.1
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
EN
31
17.REMOTE LISTENING
ESIM252 may be equipped with a microphone that allows the user to listen on his mobile phone to what is happening in the area surrounding the microphone. Remote listening feature can operate under the following conditions:
•
The system makes a phone call via GSM to a listed user phone number in case of input alarn/restore and the user answers the call.
The “conversation” will last for up to 36 seconds until the system automatically hangs up.
•
The user initiates remote listening by sending the SMS text message, the system makes a phone call to the user phone number that
the SMS text message was sent from and the user answers the call. The “conversation” will last until the user hangs up.
Initiate remote
listening
Set microphone gain
SMS
Config
Tool
SMS text message content:
ssss_MIC
Value: ssss – 4-digit SMS password.
Example: 1111_MIC
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: The system will NOT transmit any data to the monitoring station while remote listening is in progress. However, during
the remote listening process, the data messages will be queued up and transmitted to the monitoring station after the remote listening
process is over.
18.GPRS NETWORK SETTINGS
The GPRS network settings are used for device communication with the remote configuration server or monitoring station via GPRS network connection. To set the GPRS network settings, please refer to the following configuration methods.
Set APN
SMS
Set user name
SMS
Set password
SMS
View GPRS settings
SMS
SMS text message content:
ssss_SETGPRS:APN:acc-point-name
Value: ssss – 4-digit SMS password; acc-point-name – up to 31 character APN (Access Point
Name) provided by the GSM operator.
Example: 1111_SETGPRS:APN:internet
SMS text message content:
ssss_SETGPRS:USER:usr-name
Value: ssss – 4-digit SMS password; usr-name – up to 31 character user name provided by
the GSM operator.
Example: 1111_SETGPRS:USER:mobileusr
SMS text message content:
ssss_SETGPRS:PSW:password
Value: ssss – 4-digit SMS password; password – up to 31 character password provided by the
GSM operator.
Example: 1111_SETGPRS:PSW:mobilepsw
SMS text message content:
ssss_SETGPRS?
Value: ssss – 4-digit SMS password.
Example: 1111_SETGPRS?
NOTE: Multiple parameters can be set by single SMS text message, Example: 1111_SETGPRS:APN:internet;USER:mobileusr;PSW:m
obilepsw
32
EN
ESIM252 User Manual v2.1
19.MONITORING STATION
The system can be configured to report events to the monitoring station by transmitting data messages to the monitoring station. The
system connects to the monitoring station when the MS (Monitoring Station) mode is enabled.
When using the MS mode, the data messages transmitted to the monitoring station (see 19.1. Data Messages - Events) will gain the
highest priority for the delivery, therefore based on the communication method (see 19.2. Communication), a constant and stable con­
nection with the monitoring station must be ensured. In case of connection failure, the system will attempt to restore the connection and
if the monitoring is unavailable for a lengthy period of time, the system might consume a large amount of voice calls/data resulting in additional charges applied by the GSM operator according to the cell phone service plan.
Enable/disable
MS mode
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Account is a 4-digit number (By default – 9999) required to identify the alarm system unit by the monitoring station.
Set account
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
ATTENTION: The system will NOT transmit any data to the monitoring station while remote configuration, remote firmware update or
remote listening is in progress. However, during the remote configuration session or remote listening process, the data messages will be
queued up and transmitted to the monitoring station after the remote configuration session or remote listening process is over. Meanwhile, all data messages will be lost and will NOT be transmitted to the monitoring station after the firmware upgrade process is over.
19.1. Data Messages - Events
The configuration of data messages is based on Ademco Contact ID protocol. The data messages can either be transmitted to the monitoring station alone or with duplication by SMS text message to the listed user phone number. For more details on system notifications by SMS
text message, please refer to 15. SYSTEM NOTIFICATIONS.
Seq. No.
Contact ID® Code
Event
Description
1
1130
Input alarm
Transmitted in case an input is violated.
2
3130
Input restore
Transmitted in case an input is restored.
3
1602
Test event
Transmitted for system online status verification purposes.
4
3626
Date/time not set
Transmitted in case system date & time is not set.
5
1354
GPRS connection loss
Transmitted in case the GPRS connection is lost.
Manage data
messages
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
19.2.Communication
The system supports the following communication methods and protocols:
•
GPRS network – EGR100 and Kronos protocol.
•
Voice calls (GSM audio channel) – Ademco Contact ID protocol.
Any communication method can be set as primary or backup connection. The user can set up to 5 backup connections in any sequence
order.
Initially, the system communicates via primary connection with the monitoring station. By default, if the initial attempt to transmit data is
unsuccessful, the system will make additional attempts until the data is successfully delivered. If all attempts are unsuccessful, the system
will follow this pattern:
a) The system switches to the backup connection.
b) The system then attempts to transmit data by the backup connection.
c) If the initial attempt is unsuccessful, the system will make additional attempts until the data is successfully delivered. The connection is
considered unsuccessful under the following conditions:
• GPRS network – The system has not received the ACK data message from the monitoring station within 40 seconds.
• Voice calls:
ESIM252 User Manual v2.1
EN
33
• The system has not received the “handshake” signal from the monitoring station within 40 seconds.
• The system has not received the “kissoff” signal from the monitoring station within 5 attempts each lasting 1 second.
e) If one of the attempts is successful, the system will transmit all queued up data messages by this connection.
f) The system then returns to the primary connection and attempts to transmit the next data messages by primary connection.
g) If the system ends up with all unsuccessful attempts by all connections, it will wait until the Delay after last communication attempt
time (By default – 600 seconds) expires and will return to the primary connection afterwards.
h) If a new data message, except Test Event (ping), is generated during Delay after last communication attempt time, the system will immediately attempt to transmit it to the monitoring station, regardless of Delay after last communication attempt being in progress.
Set primary/backup
connection
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
If all attempts by all set connections are unsuccessful, the system will wait until the delay time (By default – 600 seconds) expires and will
attempt to transmit data to the monitoring station again, starting with the primary connection.
Set delay after last
communication
attempt
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: 0 value disables delay after last communication attempt.
NOTE: The system is fully compatible with Kronos NET/Kronos LT monitoring station software for communication via GPRS network.
When using a different monitoring station software, EGR100 middleware is required. EGR100 is freeware and can be downloaded at
www.eldes.lt/ en/download
NOTE: Voice Calls communication method is supported by product s/n: 0010742 and up.
19.2.1. GPRS Network
The system supports data transmission to the monitoring station via IP-based networks by GPRS network. The supported data formats
are the following:
• EGR100
• Kronos
To set up the system for data transmission via GPRS network, please follow the basic configuration steps:
1.
Enable MS Mode parameter (see 19. MONITORING STATION).
2.
Set 4-digit Account number (see 19. MONITORING STATION).
3.
Set server IP address, which is a public IP address of the machine running EGR100 middle-ware or Kronos monitoring station software.
4.
Set server port, which is a port of the machine running EGR100 middle-ware or Kronos monitoring station software.
5.
Select TCP or UDP protocol. UDP is highly recommended for EGR100 data format.
6.
Select data format: EGR100 or Kronos.
7.
In case EGR100 is selected, set 4-digit Unit ID number. Unit ID number can be identical to Account number.
8.
Set up APN, user name and password provided by the GSM operator. Depending on the GSM operator, only APN might be required to
set up (see 18. GPRS NETWORK SETTINGS).
For detailed step-by-step instructions on how to establish the communication between ESIM364 alarm system and EGR100 middleware,
please refer to the middleware’s HELP file.
Set server IP address
SMS
SMS text message content:
ssss_SETGPRS:IP:add.add.add.add
Value: ssss – 4-digit SMS password; add.add.add.add – server IP address.
Example: 1111_SETGPRS:IP:65.82.119.5
Set server port
SMS
SMS text message content:
ssss_SETGPRS:PORT:pprrt
Value: ssss – 4-digit SMS password; pprrt – server port number, range – [1... 65535].
Example: 1111_SETGPRS:PORT:5521
34
EN
ESIM252 User Manual v2.1
Set protocol
SMS
SMS text message content:
ssss_SETGPRS:PROTOCOL:ptc
Value: ssss – 4-digit SMS password; ptc – protocol, range – [TCP... UDP].
Example: 1111_SETGPRS:PROTOCOL:UDP
Set Set data format as
EGR100 or Kronos
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Set DNS1/ DNS2
server IP address
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Kronos NET/Kronos LT software communicates via TCP protocol, while EGR100 middle-ware v1.2 and up supports both – TCP
and UDP protocols. However, TCP protocol is NOT recommend to use with EGR100.
ATTENTION: It is necessary to restart the system locally by powering down and powering up the system the system after changing
the IP address or switching from TCP to UDP.
By default, if the initial attempt to transmit data to the monitoring station via GPRS network method is unsuccessful, the system will make
up to 2 additional attempts. If all attempts are unsuccessful, the system will switch to next backup connection that follows in the sequence
and will attempt to transmit data until it is successfully delivered to the monitoring station.
Set attempts
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
To report the online status, the system periodically transmits (By default – every 180 seconds) Test Event data message (ping) to the
monitoring station via GPRS network.
Set test period
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: 0 value disables test period.
Unit ID is a 4-digit number (By default – 0000) required to identify the alarm system unit by EGR100 middle-ware. It is MANDATORY to
change the default Unit ID before using EGR100.
Set Unit ID
View GPRS settings
Config
Tool
SMS
This operation may be carried out from the PC using the ELDES Configuration Tool software.
SMS text message content:
ssss_SETGPRS?
Value: ssss – 4-digit SMS password.
Example: 1111_SETGPRS?
NOTE: Multiple parameters can be set by single SMS text message, Example: 1111_SETGPRS:IP:22.66.33.44;PORT:1234;PROTOCOL:UDP
19.2.2.Voice Calls
The system supports up to 3 monitoring station phone numbers for communication with the alarm system by Voice Calls communication
method using Ademco Contact ID data format. Tel. Number 1 is mandatory, the other two can be used as backup phone numbers and are not
necessary. The supported phone number formats are the following:
• International (with plus) – The phone numbers must be entered starting with plus and an international country code in the following
format: +[international code][area code][local number], example for UK: +441709xxxxxxx.
• International (with 00) – The phone numbers must be entered starting with 00 and an international country code in the following
format: 00[international code][area code][local number], example for UK: 00441709xxxxxxx.
ESIM252 User Manual v2.1
EN
35
• Local – The phone numbers must be entered starting with an area code in the following format: [area code][local number], example
for UK: 01709xxxxxxx.
To set up the system for data transmission via Voice Calls, please follow the basic configuration steps:
1. Enable MS Mode parameter (see 19. MONITORING STATION).
2. Set 4-digit Account number (see 19. MONITORING STATION).
3. Set Tel. Number 1... 3.
Set/delete
monitoring station
phone number
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
By default, if the initial attempt to transmit data to the monitoring station’s Tel Number 1 via Voice Calls method is unsuccessful, the system
will make up to 4 additional attempts. After all unsuccessful attempts, the system will continue to communicate with the monitoring station by switching to the next phone number that follows in the sequence and making up to 4 additional attempts if the initial attempt is
unsuccessful. If all attempts to all phone numbers are unsuccessful, the system will switch to the backup connection and will attempt to
transmit data until it is successfully delivered to the monitoring station.
Set attempts
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Due to the individual configuration of each monitoring station, the system may fail to deliver the data message via Voice Calls communication method. In such cases it is recommended to adjust the microphone gain until the optimal value, leading to successful data message
delivery, is discovered.
Set microphone gain
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: Voice Calls communication method is supported by product s/n: 0010742 and up.
36
EN
ESIM252 User Manual v2.1
20.PROJECT EXAMPLES AND CONFIGURATION
20.1.Using in Enterprises
The user wants to connect ESIM252 system to an existing alarm system in a building where enterprise A and and enterprise B are based
at. Both enterprises use the same alarm system that features two zones. The alarm system has 5 PGM outputs.
Task NO1:
Configuring the system in the way so that the director of a particular enterprise would be informed regarding system arming depending
on which enterprise worker has carried out the system arming process. The director of enterprise A (NO1) wants to receive an SMS text
message only and does not wish to receive any calls, while the director of enterprise B (NO2) wants to receive a call and does not wish to
receive any SMS text messages.
6
PIR
PIR
Enterprise A
Director A
NO1
Enterprise B
Director B
NO2
Alarm system
PGM1
PGM2
Alarm
SMS
ESIM252
Alarm
Calls
Worker A
NO4
Worker B
NO5
Janitor
GATES
Janitor
NO3
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to remove the users that should not receive any alarm SMS text messages. In addition, by default, calls
in case of alarm are also enabled for all users, therefore this feature must be disabled for all users, except user NO2.
a) First of all the alarm system unit must be configured in the way so that arming the system in enterprise A, would result in PGM1 being
turned ON, while when the system is disarmed in enterprise B, PGM2 would result in being turned OFF.
b) PGM1 has to be connected to ESIM252 input Z1, while PGM2 must be connected to ESIM252 input Z2. (PGM2 must be of “high level”)
c) The following SMS text messages must be sent to ESIM252 system:
ssss_SMSEXTRA:Z1:SC2345,CC12345
SC2345 = alarm SMS text message sending to users NO2-NO5 is disabled if Z1 input is violated.
CC12345 = alarm calls are disabled for all users NO1-NO5 if Z1 input is violated.
ssss_SMSEXTRA:Z2:SC12345,CC1345
SC12345 = alarm SMS text message sending is disabled for all users NO1-NO5 if Z2 input is violated.
CC1345 = all alarm calls are disabled for users NO1, NO3-NO5 if Z2 input is violated.
ESIM252 User Manual v2.1
EN
37
Task NO2:
Configuring the system in the way so that the janitor (NO3) would be informed regarding the triggered PIR sensor in the secured area by
SMS text message and a phone call; when the sensor is restored, the janitor receives the SMS text message only.
7
PIR
Director A
NO1
PIR
Enterprise A
Enterprise B
Director B
NO2
Alarm system
PGM3
Worker A
NO4
ESIM252
Worker B
NO5
Janitor
GATES
Alarm
SMS/Calls
Restore
SMS
Janitor
NO3
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to remove the users that should not receive any alarm messages. In addition, by default, calls in case
of alarm are also enabled for all users, therefore this feature must be disabled for all users, except user NO3. SMS text message sending
feature must also be enabled for user NO3 when input Z3 is restored.
a) First of all alarm system unit must be configured in the way so that triggering PIR sensor would result in PGM3 being turned ON.
b) PGM3 has to be connected to ESIM252 input Z3
c) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:Z3:SC1245,CC1245,SE3
SC1245 = alarm SMS text message sending to users NO1, NO2, NO4 and NO5 is disabled after Z3 is violated.
CC1245 = alarm call feature is disabled for users NO1, NO2, NO4 and NO5 after input Z3 is violated.
SE3 = SMS text message sending feature is enabled for user NO3 after Z3 input is violated.
38
EN
ESIM252 User Manual v2.1
Task NO3:
Configuring the system in the way so that the intrusion to enterprise A premises would be reported to the janitor (NO3) and enterprise A
worker (NO4) by SMS text messages and calls. Enterprise A worker (NO4) wishes to receive a call only if the janitor (NO3) has not answered
the call, his mobile phone is out of GSM signal coverage or in case it provides a “busy” tone.
8
PIR
PIR
Enterprise A
Director A
NO1
Enterprise B
Director B
NO2
Alarm system
PGM4
Worker A
NO4
ESIM252
Alarm
SMS/Calls
Worker B
NO5
Janitor
GATES
Alarm
SMS/Calls
Janitor
NO3
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to enable mandatory SMS text message delivery and to remove the users who should not receive alarm
messages. In addition, by default, calls in case of alarm are also enabled for all users, therefore this feature must be disabled for all users,
except users NO3 and NO4. By default, in the case of alarm the system rings until the first answered call, therefore in this case nothing
should be configured.
a) First of all alarm system unit must be configured in the way so that triggering a PIR sensor of enterprise A would result in PGM4 being
turned ON.
b) PGM4 has to be connected to ESIM252 input Z4
c) The following SMS text messages must be sent to ESIM252 system:
ssss_SMSALL:ON
SMSALL = enables mandatory SMS text message delivery feature for all users.
ssss_SMSEXTRA:Z4:SC125,CC12
SC125 = alarm SMS text message delivery feature is disabled for users NO1, NO2 and NO5 if Z4 input is violated.
CC125 = alarm calls are disabled for users NO1, NO2 and NO5 if Z4 input is violated.
ESIM252 User Manual v2.1
EN
39
Task NO4:
Configuring the system in the way so that the intrusion to enterprise B premises would be reported to the janitor (NO3) and enterprise B
worker (NO5) by SMS text messages and calls, and the director of enterprise B (NO2) by SMS text message only. Enterprise B worker (NO5)
must receive a phone call even if the janitor (NR3) has answered the call.
9
PIR
PIR
Enterprise A
Director A
NO1
Enterprise B
Director B
NO2
Alarm system
PGM5
Alarm
SMS
ESIM252
Alarm
SMS/Calls
Worker A
NO4
Worker B
NO5
Janitor
GATES
Alarm
SMS/Calls
Janitor
NO3
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to enable mandatory SMS text message delivery and to remove the users who should not receive alarm
messages. In addition, by default, calls in case of alarm are also enabled for all users, therefore this feature must be disabled for users NO1,
NO2 and NO4, and left enabled for users NO3 and NO5. Also, it is necessary to enable mandatory calling feature for all listed users.
a) First of all alarm system unit must be configured in the way so that triggering a PIR sensor of enterprise A would result in PGM5 being
turned ON.
b) PGM has to be connected to ESIM252 input Z5
C) The following SMS text messages must be sent to ESIM252 system:
ssss_SMSALL:ON
SMSALL = enables mandatory SMS text message delivery feature for all users.
ssss_CALLALL:ON
CALLALL = enables mandatory calling feature for all users.
ssss_SMSEXTRA:Z5:SC14,CC124
SC14 = alarm SMS text message sending feature is disabled for users NO1 and NO4 if Z5 input is violated.
CC124 = alarm calls are disabled for users NO1, NO2 and NO4 if Z5 input is violated.
40
EN
ESIM252 User Manual v2.1
20.2.Using in a Private House
The user wants to connect ESIM252 system to the PGM outputs of an existing alarm system. House area is accessible through electrically
controlled gates. There are 5 users in total. NO1 is the housekeeper, NO2 is a neighbour, while NO3-NO5 are the family members.
Task NO1:
Configuring the system in the way so that the alarm activation in house would be reported to the housekeeper (NO1) by SMS text message
and a call as well as to the neighbour (NO2) by SMS text message only.
10
PIR
PIR
Housekeeper
NO1
Alarm
SMS/Calls
Neighbour
NO2
Alarm
SMS
Alarm system
Family members:
PGM
ESIM252
PIR
PIR
NO3
NO4 NO5
GATES
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, it is necessary to enable mandatory SMS text message delivery and to remove the users who should not receive alarm messages.
In addition, by default, calls in case of alarm are also enabled for all users, therefore this feature must be disabled for users NO2-NO5 and
left enabled for NO1 only.
a) First of all alarm system unit must be configured in the way so that triggering a PIR sensor in a house would result in PGM being turned ON.
b) PGM has to be connected to ESIM252 input Z1
c) The following SMS text messages must be sent to ESIM252 system:
ssss_SMSALL:ON
SMSALL = enables mandatory SMS text message delivery for all users.
ssss_SMSEXTRA:Z1:SC345,CC2345
SC345 = alarm SMS text message sending is disabled for users NO3, NO4 and NO5 if Z1 input is violated.
CC2345 = alarm calls are disabled for all users exept NO1 after Z1 input is violated.
ESIM252 User Manual v2.1
EN
41
Task NO2:
Configuring the system in the way so that house gates could be opened via free of charge calls by the housekeeper (NO1) and his family
members (NO3), (NO4) and (NO5). After every successful gate opening the user NO5 wishes to receive a confirmation call (CALLBACK) lasting for 3 seconds, while user NO3 wishes to receive a confirmation by SMS text message.
11
Control
Call
Confirmation
SMS
Gate controller
ESIM252
Housekeeper
NO1
Family member
NO3
Family member
NO4
Confirmation
Call
3 sek.
Family member
NO5
GATES
By default, C1 output control via calls is disabled for all users, therefore it is necessary to enable this feature and to set the users who will
be able to control the output. In addition, it is also necessary to set the output state for every user when he/she dials the system phone
number. In this case the output must be turned ON for 1 second; once this this period expires, the output will return to the previous state.
Confirmation call feature must be enabled for user NO5 and it is necessary to set the duration parameters for that call. Also, confirmation by
SMS text messages have to be enabled for user NO3.
a) First of all ESIM252 output has to be connected to the gate automation equipment.
b) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:COC:CE1345,CS5,CT513,SS3,MS10,MS30,MS40,MS50,MS1T0.0.1,MS3T0.0.1,MS4T0.0.1,MS5T0.0.1
CE1345 = C1 relay control via call is enabled for users NO1, NO3-NO5.
CS5 = confirmation call feature is enabled for user NO5 after C1 relay status changes.
CT513 = user NO5 will receive a confirmation call when the relay gets activated and call duration is 3 seconds.
SS3 = user NO3 will be informed about C1 relay status change by SMS text message.
MS10 = output is turned ON when user NO1 calls the system.
MS30 = output is turned ON when user NO3 calls the system.
MS40 = output is turned ON when user NO4 calls the system.
MS50 = output is turned ON when user NO5 calls the system.
MS1T0.0.1 = output state is changed for 1 second when user NO1 calls the system.
MS3T0.0.1 = output state is changed for 1 second when user NO3 calls the system.
MS4T0.0.1 = output state is changed for 1 second when user NO4 calls the system.
MS5T0.0.1 = output state is changed for 1 second when user NO5 calls the system.
42
EN
ESIM252 User Manual v2.1
20.3.Using with Heating System and Flood Detector
The user wants to connect ESIM252 system to the heating system of the house.
Task No1:
Configuring the system in the way so that house heating system is turned ON and turned OFF by the user (NO1) using a free of charge phone
call. This user should also receive a free of charge confirmation regarding successful turning ON or turning OFF of the heating system.
12
Flood detector
User
NO1
Heating
Controller
ESIM252
User
NO2
Confirmation
Call
3sek/10sek
Control
Call
By default, C1 output control via call is disabled for all users, therefore it is necessary to enable this feature and set the users who will be
able to control the output – in this case it is user NO1. In addition, it is also necessary to set the output state for user NO1 when he/she dials the system phone number. In this case it is necessary toset the system so that the output is turned OFF after one call and turned OFF
after another one (Toggle) and so on. User NO1 needs to enable confirmation call feature and set the duration parameters for that call. To
identify whether the output has been turned ON, the confirmation call will last for 3 seconds, while when the output has been turned OFF,
the confirmation call will last for 10 seconds
a) First of all ESIM252 output C1 has to be connected to the heating system control unit.
b) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:COC:CE1,CS1,CT113,CT1010,MS12
CE1 = C1 output control via call is enabled for users NO1.
CS1 = confirmation call feature is enabled for user NO1 if C1 output state changes.
CT113 = user NO1 will receive a confirmation call when the output is turned ON and call duration is 3 seconds.
CT1010 = user NO1 will receive a confirmation call when the output is turned OFF and call duration is 10 seconds.
MS12 = Toggle mode is enabled for user NO1, which means that the output state is changed with every call.
ESIM252 User Manual v2.1
EN
43
Task No2:
Configuring the system in the way so that users (NO1) and (NO2) receive an SMS text message regarding a burst of a water pipe (flood) at
home. SMS text messages must be delivered to both users.
13
Flood detector
User
NO1
Heating
Controller
User
NO2
Alarm
SMS
ESIM252
Alarm
SMS
By default, SMS text message sending feature in tcase of alarm is enabled for all users until the first successful delivery of the SMS text
message and calling in the case of alarm is enabled for all users until the first answered call, therefore the calls in case of alarm must be
disabled for users NO1 and NO2. Mandatory SMS delivery to all users must be enabled.
a) First of all a flood sensor has to be connected to ESIM252 input Z1.
b) The following configuration SMS text messages must be sent to ESIM252 system:
ssss_SMSALL:ON
SMSALL = enables mandatory SMS text message delivery feature for all users.
ssss_SMSEXTRA:Z1:CC12
CC12 = alarm call feature is disabled for users NO1, NO2 if Z1 input is violated. We make an assumption that users NO3-NO5 are not
listed in the system at all.
44
EN
ESIM252 User Manual v2.1
20.4.Using for Breakdown Reports
The company taking care of automatic systems needs to be informed regarding some critical breakdowns of mechanisms and has to quickly
respond in order to eliminate the breakdown. There are three members of the operating personnel (NO1), (NO2) and (NO3).
Task No1:
Configuring the system in the way so that operating personnel member (NO1) receives SMS text message regarding the breakdown of gas
boiler. While the gas boiler is operating normally it transmits a signal; when it breaks down the signal is no longer transmitted.
14
PUMP
Worker
NO1
GAS BOILER
FAULT
SIGNAL
ESIM2522
ALARM
SMS
AUTOMATIC
SYSTEM
Worker
NO2
Worker
NO3
By default, SMS text message sending feature in the case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to remove users NO2 and NO3 and disable alarm calls for all users. It is also necessary to invert ESIM252
input from NO to NC mode so that alarm is given only if the signal disappears.
a) First of all signal wires (fault output) indicating gas boiler breakdown is connected to ESIM252 input Z1.
b) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:Z1:SC23,CC123,LI1
SC23 = alarm SMS text message sending is disabled for users NO2, NO3 if Z1 input is violated.
CC123 = alarm calls are disabled for users NO1, NO2 and NO3 after Z1 input is activated. We make an assumption that users NO4-NO5
are not listed in the system at all.
LI1 = NC - “normally closed” input connection type is enabled for the input.
ESIM252 User Manual v2.1
EN
45
Task No2:
Configuring the system in the way so that the operating personnel member (NO2) receives SMS text message if the pump has been triggered for 10 times.
15
PUMP
Worker
NO1
GAS BOILER
ESIM252
ALARM
SMS
AUTOMATIC
SYSTEM
Worker
NO2
Worker
NO3
By default, SMS text message sending feature in case of alarm is enabled for all users until the first successful delivery of the SMS text
message, therefore it is necessary to remove users NO1 and NO3 and disable alarm calls for all users. It is also necessary to enable pulse
counting feature for ESIM252 input Z3 and set the number of expected pulses.
a) First of all signal wires (fault output) indicating the pump triggering has to be connected to ESIM252 input Z3.
b) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:Z3:SC13,CC123,IE1,IC10
SC13 = alarm SMS text message sending is disabled for users NO1, NO3 if Z3 input is violated.
CC123 = alarm calls are disabled for users NO1, NO2 and NO3 if Z3 input is violated. We make an assumption that users NO4-NO5 are
not listed in the system at all.
IE1 = enables pulse counting feature for input Z3.
IC10 = alarm is given by Z3 input after 10 pulses are achieved.
46
EN
ESIM252 User Manual v2.1
Task No3:
Configuring the system in the way so that operating personnel members (NO1), (NO2) and (NO3) can remotely reboot the “frozen” automatic control system by a free of charge phone call without visiting the installation location.
16
PUMP
Worker
NO1
GAS BOILER
ESIM252
CONTROL
CALLS
AUTOMATIC
SYSTEM
Worker
NO2
Worker
NO3
By default, C1 output control via calls is disabled for all users, therefore it is necessary to enable this feature and to set the users who will be
able to control the output. In addition, it is also necessary to set output state for every user when he/she dials the system phone number. In
this case the output must be turned ON for 2 seconds; once this this period expires, the output will return to the previous state.
a) First of all ESIM252 output has to be connected to the automatic system control unit.
b) The following SMS text message must be sent to ESIM252 system:
ssss_SMSEXTRA:COC:CE123,MS10,MS20,MS30,MS1T0.0.2,MS2T0.0.2,MS3T0.0.2
CE123 = C1 output control via call is enabled for users NO1-NO3.
MS10 = output is turned ON when user NO1 calls the system.
MS20 = output is turned ON when user NO2 calls the system.
MS30 = output is turned ON when user NO3 calls the system.
MS1T0.0.2 = output state is changed for 2 seconds when user NO1 calls the system.
MS2T0.0.2 = output state is changed for 2 seconds when user NO2 calls the system.
MS3T0.0.2 = output state is changed for 2 seconds when user NO3 calls the system.
ESIM252 User Manual v2.1
EN
47
21.TECHNICAL SUPPORT
21.1. Troubleshooting
Indication
Possible reason
Indicators SIM STAT and NETW are OFF
•
•
•
•
•
Indicator SIM STAT is ON
• Missing SIM card
• PIN code is enabled
• SIM card is inactive
Unable to receive any SMS text messages to the user phone number or
control the output
•
•
•
•
•
•
Unable to connect to the device remotely via GPRS connection
• GPRS settings (APN, user name, password) not set
• Insufficient SIM card credit balance
• Mobile internet service (GPRS) not activated on the
SIM card
Received SMS text message “Wrong syntax”
• Incorrect SMS text message structure
• Unnecessary space character might have been typed
in SMS text message
No mains power
Wrong wiring
Blown fuse
Disconnected antenna
Micro-controller could not start due to electrical mains
noise or static discharge
• GSM connection fault
Insufficient SIM card credit balance
Caller's phone number is set up as withheld (hidden)
No GSM network signal
Wrong user phone number
User phone number is not set
SIM card was replaced before disconnecting mains
power
• Incorrect SMS center phone number
For product warranty repair service please , contact your local retail store where this product was purchased.
If your problem could not be fixed by the self-guide above, please contact your local distributor. More up to date information about your
device and other products can be found at the manufacturer’s website www.eldes.lt
21.2. Restoring Default Parameters
1. Power down the device.
2. Short-circuit (connect) the DEF pins.
3. Power up the device for 7 seconds.
4. Power down the device.
5. Remove the short-circuit from DEF pins.
6. Parameters restored to default.
21.3. Updating the Firmware via USB Cable
1. Power down the device.
2. Short-circuit (connect) the DEF pins.
3. Connect the device via USB cable to the PC.
4. Power up the device.
5. The new window must pop-up where you will find the .bin file. Otherwise open My Computer and look for Boot Disk drive.
6. Delete the .bin file found in the drive.
7. Copy the new firmware .bin file to the very same window.
8. Power down the device.
9. Unplug the USB cable.
10. Remove the short-circuit from DEF pins.
11. Power up the device.
12. Firmware updated.
NOTE: It is strongly recommended to restore default parameters after the firmware update.
48
EN
ESIM252 User Manual v2.1
21.4.Updating the Firmware via GPRS Connection Remotely
ATTENTION: The system will NOT transmit any data to monitoring station while updating the firmware remotely via GPRS network. All
data messages will be lost and will NOT be transmitted to the monitoring station after the firmware upgrade process is over.
Before updating the firmware remotely via GPRS connection, please ensure that:
• SIM card is inserted into the SIM CARD slot (see 2.2. Main Unit, LED & Connector Functionality).
• Mobile internet service (GPRS) is enabled on the SIM card.
• ESIM252 is powered up.
• Default SMS password is changed to a new 4-digit password (see 7. SMS PASSWORD).
• User 1 phone number is set up (see 8. USER PHONE NUMBERS).
• APN, user name and password are set up (see 18. GPRS NETWORK SETTINGS).
ESIM252 system supports FOTA (firmware-over-the-air) feature. This allows to update the firmware remotely via GPRS connection. Once
the update process is initiated, the system connects to the specified FTP server address where the firmware file is hosted and begins
downloading and re-flashing the firmware. The firmware file must be located in a folder titled Firmware. In order to initiate the update
process, please send the following SMS text message.
Initiate FOTA
SMS
SMS text message content:
ssss_FOTA:ftp-server-ip,port,firmware-file-name.bin,user-name,password
Value: ssss - 4-digit SMS password; ftp-server-ip - public IP address of FTP server where
ESIM252 firmware file is stored; port - port number of FTP server (usually - 21); firmware-filename.bin - name of the firmware file, allowed max. length - up to 31 character; user-name user name of FTP server login, allowed max. length - up to 31 character; password - password
of FTP server login, allowed max. length - up to 31 character.
Example: 1111_FOTA:84.15.143.111,21,ESIM252fw.bin,eldesuser,eldespassword
ATTENTION: Firmware filename MUST be renamed in lowercase format before using it.
ATTENTION: Comma and underscore character is NOT allowed to use in user name, password and firmware file name.
ATTENTION: “ELDES UAB” does not run a FTP server and does not host the firmware files online. Please, contact your local distributor
to request the latest firmware file.
NOTE: It is strongly recommended to restore default parameters after the firmware update.
ESIM252 User Manual v2.1
EN
49
22.RELATED PRODUCTS
50
EN
ME1 – metal cabinet
EBU1 – power backup unit
Power supply
IP66 – plastic enclosure
ESIM252 User Manual v2.1
Adhesive flat GSM antenna
Manget mount straight GSM antenna
Microphone
ESIM252 User Manual v2.1
EN
51
Made in the European Union
www.eldes.lt
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement