IP OWNER'S MANUAL IP NETWORK PUBLIC ADDRESS SYSTEM M-6705

IP OWNER'S MANUAL IP NETWORK PUBLIC ADDRESS SYSTEM M-6705
IP NETWORK PUBLIC ADDRESS SYSTEM
IP
M-6705
NETWORK AUDIO ADAPTER
R
L
R
L
R
L
OWNER'S MANUAL
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
TA B L E O F C O N T E N T S
1. SAFETY PRECAUTIONS .......................................................................1
2. DESCRIPTION ......................................................................................3
3 . F E A T U R E S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4 . N O M E N C L A T U RE A N D F U N C T I O N S
4.1 Front Panel ...........................................................................................4
4 . 2 R e a r P a n e l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5. APPLICATIONS .....................................................................................6
6. BLOCK DIAGRAM..................................................................................7
7.SPECIFICATIONS .................................................................................8
1. SAFETY PRECAUTIONS
Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest Myers dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest Myers dealer.
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
2
SAFETY PRECAUTIONS
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your Myers dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
2
2. DESCRIPTION
Wall-mount IP Network Adapter with power is mainly used for family, factory, school. Hospital store
and other comercial application. With high quality and multi-fuction.
3 . F E AT U R E S
= 5 LCD English display, human operation interface.
= Paging system: PC to individual or group terminals zone and all zone paging, the network terminal also
can make zone and all zone paging to individual or group zone after authorization.
= Number key to write in and easy operation.
= Build-in order programmed module, can achieve on- line signal collection function.
= Extensible HUB module, realize hand to hand connect way.
= Support IR control to select local stored program.
= Built-in 10W stereo power amplifier.
= Aux output for bigger amplifier.
= Support local mic and line input, with volume control.
= Three levels of priority.
A.Local mic or line input priority over the system background music.
B.EMC input with priority over local input.
C.Local emergency paging with highest priority over all other inputs.
3
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel
1
2
1. DISPLAY SCREEN
Show all the operation at present
2. IR RECEIVER
Control connect port
Note:
1. Priority Control.
2. When the local audio signal input, automatic sound network media silent audio signal, the
signal size is determined by the silent sound volume control.
3. When the device with the server configuration switches pass automatically to the closure
of the local signal.
4. Machine casings and electrical power lines to connect your power supply has been inserted
into the power network grounding to prevent static damage machine.
4
NOMENCLATURE AND FUNCTIONS
4.2 Rare Panel
10
AUDIO
INPUT
L
SHORT
INPUT
1
9
8
VOLUME MUTE
R
AUDIO
OUTPUT
SPEAKER
OUTPUT
L
L
2
R
3
MIC
R
5
4
7
6
7. POWER SOURCE INPUT
1
PRESET PORT
2
SHORT CIRCUIT INPUT
~220-240V 50/60Hz
8. MUTE
External connect manual switcher
Adjust signal intensity
3. AUDIO OUTPUT
9. VOLUME
Connect with power amplifier
Adjust volume
4. SPEAKER OUTPUT
10. AUDIO INPUT
Connect with speaker
Connect with the audio signal
5. MIC INPUT
6. THERMOVENT
TERMINAL
LAN
IN
LAN 1
OUT
LAN 2
OUT
14
15
16
RF
PW
11 12
13
11. PF(STATUS INDICATOR)
Show the present operation status
12. PW(POWER INDICATOR)
It light when power connect successfully.
13. TERMINAL (terminal configuration)
Connect with serial port of PC main unit
14. LAN IN
Connect with PC main unit/ network
/ Switcher
15. LAN 1 OUT
Output to other network
16. LAN 2 OUT
Output to other network
5
5 . A P P L I C AT I O N S
CD/MP3/TUNER
AUDIO
OUT
R
COM
L
ADRESS TAG
AUDIO
INPUT
L
SHORT
INPUT
VOLUME MUTE
R
AUDIO
OUTPUT
SPEAKER
OUTPUT
L
L
R
R
MIC
MIC
Speaker
Bottom Key
Mixer amplifier
MUTE
EMC INPUT
LINE INPUT
AUX1
AUX2
OUT
OUTPUT
COM 4-16
MIC2
MIC3
MIC2
70V 100V
MIC3
TERMINAL
LAN
IN
LAN 1
OUT
LAN 2
OUT
RF
PW
Ethernet ports / switch
Ethernet interface to other equipment
PC
6
~220V -240V
50~60Hz
SHORT
INPUT
TERMINAL
LINE IN
AUDIO
INPUT
MIC
FUSE
DC24V
PT
IP
FUSE
VOL
POWER FOR CONTROL SECTION
MUTE
PA
LCD
LINE2 OUT
LINE1 OUT
SPEAKER
OUT
AUDIO
OUTPUT
6.BLOCK DIAGRAM
7
7 . S P E C I F I C AT I O N S
Network Input
Standard RJ45 3,1 Input, 2 output ( need insert the switcher)
TCP/IP UDP
Protocol Support
IGMP (group broadcasting)
Audio Format
MP3/MP2
Sampling Rate
8K-48KHz
Transmit Speed
10Mbps
Audio Format
16 digit stereo CD tone
Frequency Output
20Hz~16KHz
3%
T.H.D
>70dB
S.N
Speaker output impedance
And rated power
4
2 10W Industrial Standard Screw terminals
Aux Line Voltage Input
2 400mV Industrial Standard Screw terminals
Sources Voltage Output
8 775mV Industrial Standard Screw terminals
Source Impedance Output
Mandatory input
Working Temperature
Working Humidity
Power Consumption
Power Supply
1K
0V Industrial Standard Screw terminals
-20~+60
10%~90%
40W
~220-240V 50/60Hz
Dimension
259X187X61mm
N.W
2.2Kg
8
IP NETWORK PUBLIC ADDRESS SYSTEM
VersionV0.1