Click here to Tel Instruments Test Sets Brochure

Click here to Tel Instruments Test Sets Brochure
T-30D
CAT III NAV Ramp Test Set
Datasheet
Description
•
Permits ICAO Annex 10 CAT III ILS ramp check
certification
Checks VOR, GS, LOC, MB, Flight Director, and
Autopilot
Dual VOR/LOC/GS frequencies
Separate and simultaneous MB/ILS
Dual extended-range variable ILS
Quick, easy one-man operation from the cockpit
Lightweight and portable – weighs only 18 lbs.
Built-in NICAD battery and charger
Two year limited warranty; five & ten year available
Rugged, reliable, affordable
Backed by 40 years manufacturing experience
CE Compliant
Available non standard VOR/ILS frequencies with
local agency approval
•
•
•
•
•
•
•
•
•
•
•
•
The T-30D Ramp Test Set is designed for one-man operation of the VOR, MB, GS, LOC, flight director, and autopilot
from the cockpit or flight deck. Built into a rugged and durable case, the T-30D will permit compliance with CAT III
periodic ramp check certification in all weather conditions.
Features
VOR
LOC and G/S
• Allows selection of VOR bearing in 45º steps from 0 315°
• Manual slewing provides capability for checking fullscale deflection for “sticky” analog meter movement
(+10º)
• Permits deletion of the REF 0, VAR 0, 30 and 9960 Hz
modulation to check flag operation
• 1020 Hz tone enable switch
• Manual slewing of VOR bearing ± 10° left and right of
course
• Allows selection of preset DDM deflections of: On
Course, one and 2 dots off center
• Full-scale deflection can be tested using manual
slewing
• Allows 90 and 150 Hz tones to be deleted
• Simultaneous LOC/GS/MB Mode
• 1020 Hz tone enable switch
• Variable attenuator calibrated in 1 dB steps
• Two preset paired frequencies available
Marker Beacon and ILS
Additional Features
•
•
•
•
•
•
•
•
User selection of inner, middle, and outer marker
Simultaneous MB and ILS output signals
Variable and Preset DDM settings
Variable attenuator to control output
Specifications Subject to Change
Rugged Mil-Spec case
Built in battery and charger
100/220 volt operation 40 – 400 Hz
Simple to understand front panel and controls that
requires minimal training
• Built-In diagnostic Self Test
Copyright © Tel-Instruments Electronics Corp.
1
T-30D
Specifications
VOR Operation
LOC Operation
Frequency
108.05 MHz ± 0.025%
108.00 MHz ± 0.025%
Frequency
108.15 MHz ± 0.025%
108.10 MHz ± 0.025%
Power
+17/ ± 2 dB
Power
+17 ±2 dB
Attenuation
110 dB in 1 dB steps
Attenuation
110 dB in 1 dB steps
Modulation
Audio Frequency
Audio Frequency Accuracy
AM Depth
FM Deviation
Distortion
30/9960 Hz
± 0.01%
30 ± 2%
480 ± 30 Hz
< 5%
Modulation
Audio Frequency
Audio Frequency Accuracy
AM Depth
Distortion
Phase Accuracy
90/150 Hz
±0.01%
20 ± 2%
< 5%
90 to 1150 Hz ±10º
Indicator Deflection/Bearing
Tone
0-315° /± 0.1º in 45°
Steps/Variable ±10 º- 15°
Indicator Deflection
On Course
1020 Hz ± 2%
Variable
Step
Tone
GS Operation
Frequency
334.70 MHz ± 0.0025%
334.55 MHz ± 0.0025%
Power
+11 ±2 dB
Attenuation
110 dB in 1 dB steps
Modulation
Audio Frequency
Audio Frequency Accuracy
AM Depth
Distortion
Phase Accuracy
90/150 Hz
± 0.01%
40 ± 3%
< 5%
90 to 150 Hz ± 10º
Indicator Deflection
On Course
Variable
Step
Delete
0.0 ± 0.01DDM/0.175 ± .025
DDM
-0.175 to + 0.175 DDM
Up and Down; 1 & 2 Dots
90 and/or 150 Hz
Leading the Avionics Test Industry into the 21st Century!
Specifications Subject to Change
0.0 ± 0.01DDM/0.155 ± .02
DDM
-0.155 to +0.155 DDM
Left and Right; 1 & 2 Dots
1020 Hz ± 2%
MB Operation
Frequency
75.0 MHZ ± 0.005%
Power
+18 ± 2dB
Attenuation
110 dB in 1 dB steps
Modulation
Audio Frequency
Audio Frequency Accuracy
AM Depth
Distortion
400/1300/3000 Hz
± 2%
95 ± 4%
< 10%
Physical Characteristics
Size
14.5 x 9.4 x 6.5 in.
Weight
18 lbs.
Power
Internal Battery or external
120/220 VAC 50-400 Hz
Environmental
Storage- -51° to + 71° C
Operating -30° to +55ºC
Tel-Instrument Electronics Corp.
728 Garden Street
Carlstadt, NJ 07072
(201) 933-1600
www.telinstrument.com
Copyright © Tel-Instruments Electronics Corp.
2
T-36C
NAV/COMM Test Set
Datasheet
Description
The T-36C is a rugged-designed, user-friendly, highprecision instrument for rapid functional testing of VOR,
LOC/GS, MB, and VHF COMM (AM/FM) avionic
equipment.
With an intuitive and simple operator interface and
battery operation of up to 8 hours on one charge, the
T-36C navigation and communication capabilities allows
the user to quickly, test, troubleshoot, and isolate
problem systems on the ramp and in the shop.
The T-36C RF output allows testing from the flight deck
of most large aircraft using an expandable, omnidirectional antenna. Testing of all functions can also be
performed with the unit-under-test (UUT) directly
connected to Test Set.
Features
•
Tests VOR, LOC, GS, MB, VHF, and UHF COMM
•
Large easy to read backlit display
•
Pre-programmed test scenarios and settings
•
Simple user interface and clearly identified switches
•
Simultaneous LOC, G/S and MB output
•
Key board entry of nearly limitless parameters
•
Allows testing at 25 kHz and 8.33 kHz spacing
•
Internal battery charger included
•
Compliant with European CE requirements
•
Standard 2 year limited warranty included
VOR
Communications (COMM))
• Accurate generation of 30 Hz variable, reference, and
9960 Hz sub-carrier.
• Preset bearing simulation in 45° or slew in 1°
increments.
• 30 Hz and 9960 Hz modulation can be deleted to check
flag operation.
• Covers the entire VOR band of 108.00 to 117.95 MHz.
• 1020 Hz IDENT tone
• AM or FM with variable modulation and deviation
settings.
• VSWR measurement allows testing of antenna system.
• Direct Connect and Antenna methods add versatility and
accuracy.
• 25 MHz and 8.33 kHz channel selection.
• Accurate measurement of VHF/UHF frequency, power,
and modulation.
LOC and GS
Marker Beacon and ILS
• Precise simulation of LOC/GS ground station signals.
• Allows selection of preset DDM deflections or manual
slew in 0.001 increments.
• Simultaneous LOC/GS/MB Mode.
• Allows 90 and 150 Hz tones to be deleted
• Easy user selection of 400, 1300, and 3000 Hz signals.
• Simultaneous MB and ILS output signals.
• Separate adjustment of DDM values, either preset or
slew, in ILS.
Specifications Subject to Change
Copyright © 2006 Tel-Instrument Electronics Corp.
9 October 2006
1 of 4
T-36C
Specifications *
* Standard Condition Values – As specified in
Maintenance Manual and at selected Cal Positions.
TRANSMITTER Characteristics
RF FREQUENCIES
FUNCTION
Marker
VOR OMNI
Localizer**
Glide Slope**
COMM
PRESET FREQUENCY VALUES***
KEYPAD ENTRY FREQUENCY CAPABILITY
KNOB
LO
MID
HI
FROM
TO
ACCURACY
MB
VOR
LOC
GS
108-174
74.50 MHz
108.00 MHz
108.10 MHz
334.70 MHz
108.00 MHz
75.00 MHz
108.05 MHz
108.15 MHz
334.55 MHz
113.00 MHz
75.50 MHz
117.95 MHz
110.15 MHz
334.25 MHz
174.95 MHz
74.5000 MHz
108.0500 MHz
108.1000 MHz
329.1500 MHz
108.0000 MHz
75.5000 MHz
117.9500 MHz
119.9500 MHz
335.0000 MHz
118.0000 MHz
± 150 Hz
± 150 Hz
± 150 Hz
± 300Hz
± 150 Hz
FREQUENCY SPACING IS IN 25 KHZ AND 8.33 KHZ STEPS
** Localizer and Glideslope Frequencies are Automatically Paired
***All preset values can be user modified and saved to memory
Power Output
FREQUENCY
RANGE
ANTENNA
108 to 118 MHz
0 to -70 dBm
118 to 156 MHz
0 to -60 dBm
156 to 174 MHz
0 to -60 dBm
Selectable in 1 dB steps
FREQUENCY
RANGE
TOLERANCE
DIRECT CONNECT (RT Port)
108 to 117.95 MHz
-25 to -100 dBm
± 2 dB
118 to 156 MHz
-25 to -90 dBm
± 2 dB
156 to 174MHz
-25 to -90 dBm
± 2 dB
Selectable in 1 dB steps
TOLERANCE
± 2.5 dB
± 2.5 dB
± 2.5 dB
NAVIGATIONAL Characteristics
FUNCTION
FREQUENCY
Marker
CONDITIONS
0.4, 1.3, 3.0 kHz
VOR OMNI
9960 Hz & 30 Hz
Bearing Accuracy
FM Modulation
VOR Presets
0o
DEFAULT
ACCURACY
RANGE
RESOLUTION
SWITCH NAME
-----
-----
TONES
----95 % mod
+/- 5 %
Tone Frequency Accuracy ± 8 Hz @ 0.4, 1.3, 3.0 kHz
0o Bearing
30 % mod
+/- 2 % Mod.
0° to 360°
1°
ILS/VOR VAR
± 1° at 0° degree bearing
30 Hz reference at ± 480 Hz Peak deviation on 9960 Hz Sub carrier
Accuracy ± 30 Hz at peak deviation
45
90
135
180
225
270
315
360
Key Pad Variable - 0°to 360° in 1° inc.
Glide Slope
90 Hz & 150 Hz
± 1%
@ 0.0 DDM
40 % mod
+/- 2 % Mod.
0 to 0.400 DDM
(U/D)
0.001 DDM
ILS/VOR VAR
Localizer
90 Hz & 150 Hz
± 1%
@ 0.0 DDM
20 % mod
+/- 2 % Mod.
0 to 0.200 DDM
(L/R)
0.001 DDM
ILS/VOR VAR
PRESETS
LOC
GS
IDENT
DDM
DDM
1020 Hz
U1/R1 U2/R2
FS
0C
FS
D2/L2
D1/L1
0.093
0.155
0.200
0.000
0.200
0.155
0.093
0.091
0.175
0.400
0.000
0.400
0.175
0.091
Key Pad Variable DDM in .001 DDM increments to full scale
VOR
10% Fixed
+/- 5 % Mod
± 50 Hz.
-----
Accuracy at “ON COURSE” (OC)
LOC
± 0.002 DDM
GS
± 0.002 DDM
-----
MB/NAV ID
Tel-Instrument Electronics Corp.
728 Garden Street
Carlstadt, NJ 07072
(201) 933-1600
www.telinstrument.com
Specifications Subject to Change
Copyright © 2006 Tel-Instrument Electronics Corp.
9 October 2006
2 of 4
T-36C
COMMUNICATIONS Characteristics
FOR FREQUENCY RANGES – SEE TRANSMITTER CHARACTERISTICS SECTION
Communication Modes
Communication AM
Communication Tones AM
Variable Range - 0 to 95% AM
Audio Output Level
Communication FM
AM, FM, UHF and VHF in Amplitude Modulation (AM) and Frequency Modulated (FM)
1020 Hz
150 Hz
100 – 900 mv in 100 mv steps
Accuracy ± 50 Hz
Accuracy ± 50 Hz
Range from 1 kHz - 10 kHz
Deviation in 1 kHz steps
1020 Hz
100 – 900 mv in 100 mv steps
FM Modulation Variable
Tone
Output Level
Modulation ± 5% @ 120 MHz
Modulation ± 5% @ 120 MHz
Accuracy ± 50 mv
± 2 kHz Deviation / 1020 Hz @ 120 MHz
Accuracy ± 50 Hz
Accuracy ± 50 mv
RECEIVER Characteristics
Frequency Range
Same as COMM Ranges
Maximum Input Level (RT port)
25 W
Power Measurement Accuracy
+/-20 % (CW Only)
AM Measurement Range
FM Measurement Range
Sensitivity (Antenna port)
VSWR Measurement
0 to 100% Modulation
0 to 15 kHz
-10 dBm AM; -30 dBm FM
1.0 to 5.0; +/- 1
Frequency Counter
Measurement Accuracy
+/-500 Hz of selected Frequency
Power Measurement Range
0 dBW to +14 dBW (1 to 25 W)
Direct Connect (CW Only)
AM Measurement Tolerance
FM Measurement Tolerance
+/- 5% @ 120 MHz
+/- 2 kHz @ 120 MHz
MISCELLANEOUS SPECIFICATIONS & Characteristics
Size
Weight
Case Style
Input Power
Requirements
Input Power Frequency
AC Fuse Requirements
15.5 X 9.4 X 6.5 inches
20 pounds
MIL-PRF-28800, Class 2
100 to 240 VAC+/- 10%
Operating Temperature
Storage Temperature
Case Color
Input Power Consumption
-28o C to +55o C
-50oC to +70oC
Yellow
20 Watts
50 to 400 Hz Input Current
0.17 Amps AC
1.0 A SB (2 req.) DC Fuse Requirements
5.0 A SB (2 req.; internal to Test Set)
Note: Input power specified for battery charging simultaneously with Test Set operation.
Standard Accessories and Options
•
•
•
•
Standard 2 Year Limited Warranty included
Multi Band Omni Antenna
Operational and Maintenance Manual
AC Power Cord
•
•
•
Direct Connect Cable
All Accessories store in Test Set cover
5 & 10 Year Warranty Plans available
Tel-Instrument Electronics Corp.
728 Garden Street
Carlstadt, NJ 07072
(201) 933-1600
For more information on our exciting product lines
Specifications Subject to Change
www.telinstrument.com
Copyright © 2006 Tel-Instrument Electronics Corp.
9 October 2006
3 of 4
Tel-Instrument Commercial
Product Lines
TB-2100 ATC/DME Bench Test Set
•
Test Transponder, ATCRBS, and Mode S with unrivaled accuracy
•
Color LCD touch display features wide viewing
•
Continuous display of critical measurements including power, pulse
•
Easy to navigate menus require minimal training to operate
•
IEEE Compatible
angle
parameters, percent reply, and frequency
TR-220 Multi-Function Test Set
Test TCAS, DME, and Transponder
•
Transmits and receives ADS-B (1090 MHz squitter)
•
Transmits Traffic Information System (TIS) intruder flight data
•
Meets test requirements for European Mode S Elementary and EHS
•
Performs test requirements per FAR Part 43, Appendix F
•
Allows DME testing on all channels (108.00 to 117.95 MHz)
•
Compliant with European CE requirements
•
TR-211 Multi-Function Test Set
•
Test DME and Transponder with Elementary and EHS
•
Receives and displays ADS-B (1090 MHz squitter)
•
Transmits TIS intruder flight data for 4 intruders
•
Performs test requirements per FAR Part 43, Appendix F
•
Allows DME testing on all channels (108.00 to 117.95 MHz)
•
Compliant with European CE requirements
T-30D Navigation Test Set
Test VOR, Localizer, Glideslope, and Marker Beacon
•
Easy to use, one-man operation
•
Full range of tests to comply with CAT III periodic ramp certification
•
Fully adjustable functions allow precise testing and measurement
•
Allows testing from flight deck
•
FlexiBus Databus Analyzers
•
Displays ARINC 429 data in Engineering and /or Hex formats
•
Up to 60 user tables permit storage and recall of commonly
•
Receive 1024 label/SDI combinations
•
Trap and store 3500 ARINC 429 labels
•
Rechargeable NI-MH batteries permits up to 24 hours of operation
used transmitted words
Tel-Instrument Electronics Corp.
Leading the Avionics Test Industry into the 21st Century
Specifications Subject to Change
Copyright © 2006 Tel-Instrument Electronics Corp.
9 October 2006
4 of 4
TB-2100
ATC/DME/MODE S Test Set
Datasheet
Description
The TB-2100 is a modern, easy to use bench test set
designed for testing Mode A, C, and S transponders
and distance measuring equipment (DME).
The TB-2100 allows testing of Mode S transponders
with new capabilities including, Extended Squitter,
ADS-B, TIS, Elementary (ES) and Enhanced
Surveillance (EHS), and including evolving European
requirements.
The TB-2100 with IEEE-488 option uses the same
IEEE-488 commands as older generation ATC/DME
and Mode S test sets used in current generation ATE.
P/N – 90 000 106
Features
•
Two independent, non-coherent, RF channels for Mode S testing
•
Tests the latest Mode S Capabilities
o Automatic Dependent Surveillance Broadcast (ADS-B)
o Extended Squitter
o Elementary (ES) and Enhanced Surveillance (EHS)
o Traffic Information Systems (TIS)
•
Easy to Use
o Modern front-panel provides simple, intuitive, interface
o Multiple, variable rate slew knobs control pulse width, power, repetition rates, and
position
o Keypad supports direct test parameter entry
o Large color, touch-pad display, which continuously presents critical measurement
information and permits immediate test parameter selection
o Quick recall of standard test conditions using CAL button
•
Additional Benefits
o
o
o
o
Provides video and RF signal feeds plus scope triggers
Can be connected to spectrum analyzers and other bench equipment
Flash memory provides easy update/upgrade path
Standard 2 year limited warranty; extended warranty available
Specifications Subject to Change without Notice - 9/30/07
Standard Condition Values
Copyright © Tel-Instrument Electronics Corp. 2007
TB-2100
Product Specifications
The TB-2100 features test capability for DME and transponders
ATCRBS and Mode S).
Specifications
Signal Generator
Frequency Range
Frequency Accuracy
Frequency vs. Level Flatness
Signal Level Range
Signal Level Accuracy
On/Off Ratio
Suppressor Pulse Amplitude
Suppressor Pulse Width
952.00 to 1223.00 MHz
+ 0.001%
<1.0 dB
0 to -100 dBm into 50 Ω, 1 dB resolution
0 to -50 dBm + 0.75 dB
-51 to -79 dBm + 1.0 dB
-80 to -89 dBm + 1.1 dB
-90 to -100 dBm + 1.2 dB
> 60 dB
Variable from 9 to 28 V
35 + 5 µs
P4 Width
Sync Phase Reversal
(SPR relative to P2)
P5 Position
(Relative to SPR)
P6 Position
(Relative to SPR)
Interference Pulse Position
(Relative to P1)
Interference Pulse Width
Interference Pulse/P5 Level
(relative to P1)
0.80 or 1.60 + 0.5 µs, variable -0.50 to 1.00 µs
2.75 + 0.05 µs, variable -0.50 to +0.50 µs
0.40 + 0.05 µs before SPR, variable -1.00 to
+1.00 µs
1.25 + 0.50 µs before SPR, variable -0.40 to
+3.00 µs
-1.40 to +45 + .05 µs , variable in 50 ns steps
0.30 to 3.00 µs + 1%, variable in 50 ns steps
-15 to +3 dB + 0.25 dB, variable in 1 dB steps
DME Mode
UUT Measurements
Mode
Frequency
Power
1020 to 1155 MHz; + 20 kHz for ATC; + 50 kHz
for DME
0 to 4000 W pk; + 0.7 dB 1 to 99 W; + 0.5 dB
100 to 4000 W
Pulse Characteristics
P1 Rise time
P1 Fall time
P1 Width
P2 Rise time
P2 Fall time
P2 Width
P2 Position
(Relative to P1)
Transponder Modes
Mode
ATCRBS and Mode S
Pulse Characteristics
Rise time (P1)
Fall time (P1)
75 + 25 ns
150 + 50 ns
Echo Position (30 nmi)
Scope Sync Width
PRF
15/135 Hz Modulation
Percent Modulation
15 Hz Modulation
135 Hz Modulation
Reply Efficiency
Range
ATCRBS Mode A/C
Pulse Width (P1/P2/P3)
P2 Position (Relative to P1)
Mode C P3 Position (Relative
to P1)
Interference Pulse Width
Interference Pulse Position
(Relative to P1)
Interference Pulse
RF source
Interference Pulse/SLS Level
(relative to P1)
PRF
Scope Sync Width
Scope Sync Position
(Relative to P1)
A/C Interlace Mode
Interrogation Spacing
Double Mode Interrogation
Interrogation Spacing
0.80 + .05 µs, variable -0.3 to 1.4 µs in 50 ns
steps
2.00 + .05 µs, variable + 1.00 µs in 50 ns steps
21.00 + .05 µs, variable + 1.00 µs in 50 ns
steps
0.30 to 3.00 µs + 1%, variable in 50 ns steps
-5 to +45 + .05 µs , variable in 50 ns steps
Velocity
Selectable for coherent or non-coherent
-15 to +3 dB + 0.25 dB, variable in 1 dB steps
Echo Level
Front Panel BNC Connectors
0.1 to 2500 Hz
0.8 to 1.2 µs
0 to 175 µs in 1 µs steps
Rear Panel BNC Connectors
1.00 + 0.20 ms
3 to 500 µs
Mode S
Pulse Width (P1/P2/P3)
P2 Position (Relative to P1)
Mode A P3 Position (Relative
to P1)
Mode C P3 Position (Relative
to P1)
P4 Position (Relative to P3)
0.80 + .05 µs, variable -0.3 to 1.4 µs in 50 ns
steps
2.00 + .05 µs, variable + 1.00 µs in 50 ns steps
8.00 + .05 µs, variable + 1.00 µs in 50 ns steps
21.00 + .05 µs, variable + 1.00 µs in 50 ns
steps
2.00 + 0.5 µs, variable + 1.00 µs in 50 ns steps
VOR Pair, TACAN Channel, MHz
2.0 +/- 0.5 us
2.5 +/- 0.5 us
3.5 +/- 0.2 us
2.0 +/- 0.5 us
2.5 +/- 0.5 us
3.5 +/- 0.2 us
X Mode – 12.0 + 0.2 µs, variable -6.00 to +6.00
in 0.1 µs steps
Y Mode – 30.0 + 0.2 µs, variable
-6.00 to +6.00 in 0.1 µs steps
426.65 +/- .25 us
0.8 to 1.2 µs
1 to 5000 Hz
30 to 50 %
15 +/-1 Hz
135 +/-2 Hz
0 to 100% + 5%, selectable in 10% increments
0 to 998 nmi. + 0.02 nmi. Plus + 0.005% of
selected range
0 to 9990 kts. + 0.05%, selectable in 0.01 nmi.
Increments
-12 to +3 dB + 0.25 dB, variable in 1 dB steps
Spectrum Analyzer (Top and Main)
UUT Video (Top and Main)
Test Set Video (Top and Main)
Scope Sync
Suppressor Pulse (ATC and DME)
RS-232 (Calibration and Software Update)
IEEE-488 Connector
DPSK Modulation Input
External SLS
Video Input for Mode S Interrogation
Low Power Input
External Trigger
Calibration Marks
General
Power
Dimensions
Weight
Temperature
100 to 120 VAC, 60 Hz; 220 to 240 VAC, 50 Hz
14.5 in. W x 11.0 in. H x 14.25 in. D
368 mm W x 279 mm H x 362 mm D
28 lbs. (12.7 kg.)
5 to 40°C
Tel-Instrument Electronics Corp.
728 Garden Street
Carlstadt, NJ 07072
(201) 933-1600
www.telinstrument.com
Specifications Subject to Change without Notice - 9/30/07
Standard Condition Values
Copyright © Tel-Instrument Electronics Corp. 2007
TR-220
Multi-Function Test Set
Datasheet
Description
Description
The TR-220 provides test capability for
Traffic and Collision Avoidance Systems
(TCAS), Distance Measuring Equipment
(DME), and Transponders (Modes A, C,
and S). The TR-220 features state-of-the
art design technology.
Microprocessor
control results in easy-to-use operation
that requires minimum amounts of training.
Setup menu allows storage of various test
parameters to facilitate quick recall of test
conditions.
•
•
•
•
•
•
•
•
Tests TCAS, DME, and Transponder
Transmits and receives ADS-B (1090 MHz squitter)
Transmits Traffic Information System (TIS) intruder flight data
Performs test requirements per FAR Part 43 Appendix F
Meets European test requirements for Mode S Elementary and Enhanced Surveillance
Compliant with European CE requirements
2 year limited warranty; Extended warranty available
P/N 90 000 088
Transponder
Features
• Test Set automatically determines capability of transponder being tested (ATCRBS or Mode S) and selects
appropriate tests
• Testing can be done over-the-air, using directional antenna, or directly connected to transponder
• Test Set can be configured for automatic sequencing or manual control of individual transponder tests
TCAS
•
•
•
•
Test set allows storage of 10 intruder scenarios, to simplify TCAS testing
Allows simulation of ATCRBS or Mode S intruder
User selection of velocity, starting distance, starting altitude, and vertical speed
Measures UUT power and frequency
DME
•
•
•
•
Allows testing on all channels (108.00 to 117.95 MHz)
Measures DME power, frequency, and PRF
Transmits DME Morse-Code I.D.
User selection of DME distance and velocity
Specifications Subject to Change
11/4/04
Copyright © Tel-Instruments Electronics Corp.
TR-220
Transponder Test Specifications *
The TR-220 performs the following tests based on the capabilities of the transponder:
ƒ Mode A - 4096 code, IDENT, percent reply, pulse spacing, pulse width
ƒ Mode S Enhanced Surveillance parameters, including Selected
ƒ Mode C - Altitude (feet and grey code), percent reply, pulse spacing,
Altitude (BDS4); Roll Angle, True Track Angle, Ground Speed, Track
pulse width
Angle Rate, and True Airspeed (BDS5); Magnetic Heading, Indicated
ƒ Side-lobe suppression (SLS)
Airspeed, Mach #, Barometric Altitude Rate, and Inertial Vertical
ƒ Mode A/S and C/S All Call - Mode S address, percent reply
Velocity (BDS6)
ƒ Mode A Only and Mode C Only
ƒ Receives and decodes 1090 MHz ADS-B data, including squitter type
ƒ Mode S Surveillance I.D. (DF5) – Mode S address, percent reply, flight
(airborne position, surface position, aircraft identification/category, and
status (Air, Ground, Alert, SPI), Mode S/Mode A 4096 code compare
airborne velocity), latitude/longitude, N/S velocity, E/W velocity, Flight
(automatic mode)
I.D., Mode S address, altitude (GNSS or barometric), and airspeed
ƒ Mode S Surveillance Altitude (DF4) – Mode S altitude, percent reply,
ƒ Transmits 1090 MHz ADS-B data for four intruder aircraft (airborne or
Mode S/Mode C altitude compare (automatic mode)
surface position)
ƒ Mode S Surveillance Short (DF0) – Mode S address, vertical status
ƒ Transmits TIS data for four intruder aircraft
(Air, ground), percent reply, decoded country code, decoded tail
Transmitter
Frequency
1030 MHz + 100 KHz
number (if applicable)
Power
> 4 dBm
ƒ Mode S Comm. I.D. (UF5/DF21) – Mode S ID code, percent reply
Modes
A, C, S
ƒ Mode S Comm. Altitude (UF4DF20) – Mode S altitude, percent reply
ƒ Undesired replies (UF11) – Checks for reply to incorrect Mode S
Receiver
Frequency
Range
1086.5 to 1093.5 MHz
interrogation
Accuracy
+ 200 KHz
ƒ Acquisition squitter – Pass/Fail indication of squitter duration, decoded
Power
Range
47 to 64 dBm
Mode S address, interrogator code
Accuracy
+ 2 dB (direct connect)
ƒ Extended squitter – Pass/Fail indication of squitter duration, decoded
+ 3 dB (radiated)
Mode S address
Sensitivity
Range
-50 to -87 dBm
ƒ Max Airspeed – Decodes and displays maximum airspeed
Accuracy
+ 2 dB (direct connect)
ƒ Diversity – Displays Pass/Fail indication and measured value of RF
+ 3 dB (radiated)
leakage through Mode S transponder antenna ports
Reply Percent
Range
0 to 100%
ƒ Sensitivity (MTL) – Measures and displays MTL for Modes A, C, and S
Accuracy
+ 1%
ƒ Measures and displays transponder power (dBm or watts), frequency,
and receiver sensitivity (dBm)
ƒ Decodes and displays Flight I.D.
ƒ Decodes and displays Mode S address in Octal and Hex
TCAS Test Specifications *
The TR-220 allows testing of TCAS I, TCAS II, and Traffic Advisory
Systems by simulating either ATCRBS or Mode S intruders. The
Setup menu allows operator to configure and store 10 TCAS
scenarios, including Distance (1 to 50 NMI), Altitude (-1000 to
+99,900 ft.), Vertical Speed (-7,500 to +7,500 fpm) and Velocity (100
to 1200 KTS.). The TR-220 provides a relative measurement of
TCAS power and frequency.
Transmitter
Frequency
Power
Modes
1090 MHz + 100 KHz
> 4 dBm
C, S
Receiver
Frequency
Power
1026.5 to 1033.5 MHz
47 to 64 dBm
Transmitter
Frequency
Power
962 to 1213 MHz + 100 KHz
> 4 dBm
Receiver
Freq. Range
Freq. Accuracy
Sensitivity
Range
Channel Freq. + 3.5 MHz
+ 200 KHz
< -35 dBm
DME Test Specifications *
The TR-220 provides test capability for DME by allowing
operator to select test parameters, including Channel (108.00
to 117.95 MHz) and Velocity (120 to 1200 KTS.).
The TR-220 measures and displays DME PRF (scan rate),
power, and frequency. Also, the TR-220 transmits a Morse
Code I.D.
Accessories
Directional antenna (hand-held or mounted on side of case)
AC Power Cord
Direct Connect Cable
Directional Antenna Cable
Operators Manual
TAP-200 Anti-Radiation Coupler (Optional)
Physical
Packaging - MIL-PRF-28800, Style C
Size: 14.5x9.4x6.5 in. (36.8x23.9x16.5 cm.)
Weight: 20 lbs. (9.1 kg.)
Operating Temperature: -28 to +55 C
Battery Operation; 8 hours at 20% Duty Cycle
AC Operation/Charging: 100-240 VAC, 50-400 Hz
* Standard condition values
728 Garden St., Carlstadt, NJ USA Tel. +1 (201) 933-1600 Fax +1 (201) 933-7340
www.telinstrument.com
Specifications Subject to Change
11/4/04
Copyright © Tel-Instruments Electronics Corp.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement