01k7522
IBM Netfinity Rack
Planning and Installation Guide
IBM
IBM Netfinity Rack
Planning and Installation Guide
Note
Before using this information and the product it supports, be sure to read the general information under
Appendix B, “Product Warranties and Notices” on page 35.
First Edition (August 1998)
The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with
local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied
warranties in certain transactions, therefore, this statement may not apply to you.
This publication could include technical inaccuracies or typographical errors. Changes are periodically made to the information
herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the
product(s) and/or the program(s) described in this publication at any time.
This publication was developed for products and services offered in the United States of America. IBM may not offer the products,
services, or features discussed in this document in other countries, and the information is subject to change without notice. Consult
your local IBM representative for information on the products, services, and features available in your area.
Requests for technical information about IBM products should be made to your IBM reseller or IBM marketing representative.
 Copyright International Business Machines Corporation 1998. All rights reserved.
Note to U.S. Government Users — Documentation related to restricted rights — Use, duplication or disclosure is subject to
restrictions set forth in GSA ADP Schedule Contract with IBM Corp.
Contents
Safety Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Danger and Caution References
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vii
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiv
xiv
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
About This Book . . .
What This Book Contains
Product Description
Product Specifications . .
Preparing the Physical Site
Electrical Requirements . .
Limitations . . . . . . . . . .
World Wide Web Information
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Available Options . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fixed Shelf
19-Inch Single-Slide Shelf . . . . . . . . . . . . . . . . . . . . . .
Keyboard Tray (with keyboard and mouse extension cables) .
Monitor Compartment . . . . . . . . . . . . . . . . . . . . . . . .
Rack Attachment Kit (IBM 9306 Model 900 Netfinity Rack Only)
Blank Filler Panel Kit . . . . . . . . . . . . . . . . . . . . . . . . .
Side Panel Kit (IBM 9306 Model 900 Netfinity Rack Only) . . .
Console Cable Set . . . . . . . . . . . . . . . . . . . . . . . . . .
Console Server Selector Switch . . . . . . . . . . . . . . . . . .
100–120 V Power Distribution Unit (PDU)
. . . . . . . . . . . .
200–240 V Power Distribution Unit . . . . . . . . . . . . . . . . .
APC Smart-UPS Uninterruptible Power Supplies
. . . . . . . .
Power Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IBM Netfinity Rack Configurator Program
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
24
Netfinity Rack Cables Installation Guidelines
Rack Relocation Safety Guidelines
2
6
7
8
10
11
11
11
12
12
12
12
12
12
13
13
13
14
15
Rack Option and Equipment Installation Guidelines
Unpacking the Netfinity Rack . . . . . . . .
Removing the Packaging Materials
. . . . .
Removing the Rack from the Shipping Pallet
Locating the Rack . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing and Installing the Front and Rear Doors
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Netfinity Rack Side Panel Kit Removal and Installation
Appendix A. Help and Service Information
25
26
27
28
30
. . . . . . . . . . . . . . . . . . . . . . . . . .
31
. . . . . . . . . . . . . . . . . . . . . . . . . . .
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
Removing and Installing the Horizontal Side Braces
 Copyright IBM Corp. 1998
v
iii
Step 1: Troubleshooting
. . . . . . . .
Step 2: Preparing for the Service Call
Step 3: Placing the Service Call to IBM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix B. Product Warranties and Notices
Notices . . . . . . . . . . . . . . . . . . . . . . . .
Trademarks . . . . . . . . . . . . . . . . . . . . .
iv
IBM Netfinity Rack
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
34
34
35
37
37
Safety Information
Before installing this product, read the Safety Information book.
Antes de instalar este produto, leia o Manual de Informações sobre Segurança.
Před instalací tohoto produktu si přečtěte příručku bezpečnostních instrukcí.
Læs hæftet med sikkerhedsforskrifter, før du installerer dette produkt.
Lue Safety Information -kirjanen, ennen kuin asennat tämän tuotteen.
Avant de procéder à l'installation de ce produit, lisez le manuel Safety Information.
Vor Beginn der Installation die Broschüre mit Sicherheitshinweisen lesen.
Installálás előtt olvassa el a Biztonsági előírások kézikönyvét !
Prima di installare questo prodotto, leggere l'opuscolo contenente le informazioni sulla sicurezza.
Lees voordat u dit product installeert eerst het boekje met veiligheidsvoorschriften.
Les heftet om sikkerhetsinformasjon (Safety Information) før du installerer dette produktet.
Przed zainstalowaniem tego produktu należy przeczytać broszurę Informacje Dotyczące
Bezpieczeństwa.
Antes de instalar este produto, leia o folheto Informações sobre Segurança.
Перед установкой продукта прочтите брошюру по технике безопасности
(Safety Information).
Pred inštaláciou tohto produktu si prečítajte Informačnú brožúrku o bezpečnosti.
 Copyright IBM Corp. 1998
v
Preden namestite ta izdelek, preberite knjižico Varnostne informacije.
Antes de instalar este producto, lea la Información de Seguridad.
Läs säkerhetsinformationen innan du installerar den här produkten.
vi
IBM Netfinity Rack
Danger and Caution References
Important:
All caution and danger statements in this book begin with a number. This number is used to cross
reference an English caution or danger statement with translated versions of the caution or danger
statement that can be found in the Caution and Danger Information book.
For example, if a caution statement begins with a number 1, translations for that caution statement
appear in the Caution and Danger Information book under statement number 1.
Be sure to read all caution and danger statements in this book before performing any of the
instructions.
Importante:
Todos os avisos de cuidado e perigo deste manual começam por um número. Este número é
utilizado como referência de um aviso de cuidado ou perigo em inglês para a sua versão traduzida
que poderá ser encontrada no Manual de Informações de Cuidado e Perigo.
Por exemplo, se um aviso de cuidado começa pelo número 1, a tradução para ele aparecerá. no
Manual de Informações de Cuidado e Perigo, como aviso número 1.
Certifique-se de ler todos os avisos de cuidado e perigo contidos neste manual antes de seguir
qualquer instrução.
Důležité:
Všechny bezpečnostní instrukce v této knize začínají číslem. Tato
čísla jsou používána pro nalezení odpovídajícího překladu anglické
bezpečnostní instrukce v knize Caution and Danger Information.
Například pokud bezpečnostní instrukce začíná číslem 1, naleznete
odpovídající překlad v knize Caution and Danger Information pod
číslem 1.
Ujistěte se, že jste si přečetli všechny bezpečnostní instrukce z této
knihy.
 Copyright IBM Corp. 1998
vii
Vigtigt:
Alle sikkerhedsforskrifter i dette hæfte begynder med et tal. Dette tal bruges som krydshenvisning
fra en engelsk sikkerhedsforskrift mærket CAUTION eller DANGER til de oversatte forskrifter, der
findes i hæftet Caution and Danger Information.
Hvis f.eks. en sikkerhedsforskrift mærket Pas på! begynder med tallet 1, er oversættelsen af denne
forskrift nummer 1 i hæftet Caution and Danger Information.
Læs alle sikkerhedsforskrifter mærket Pas på! og Fare! i dette hæfte, før du følger nogen af
instruktionerne.
Tärkeää:
Kaikkien tämän kirjan Varoitus- ja VAARA-turvaohjeiden alussa on numero, jonka avulla
englanninkielistä ohjetta vastaava suomenkielinen ohje löytyy helposti julkaisusta Caution and
Danger Information.
Esimerkiksi numerolla 1 merkityn varoituksen erikieliset käännökset ovat julkaisussa Caution and
Danger Information turvaohjeen numero 1 kohdalla.
Lue kaikki julkaisussa olevat turvaohjeet, ennen kuin aloitat ohjeissa kuvatut toimet.
Important:
Dans le présent manuel, toutes les consignes de sécurité Attention et Danger sont précédées d'un
nombre qui permet d'établir la correspondance entre la consigne Attention ou Danger en anglais et
sa version traduite. Toutes ces consignes se trouvent dans le manuel Caution and Danger
Information.
Par exemple, si une consigne Attention est précédée d'un 1, les versions de cette consignes,
traduites dans plusieurs langues, apparaîtront dans la section des consignes 1 dans le manuel
Caution and Danger Information.
Veillez à lire toutes les consignes Attention et Danger du présent manuel avant de procéder à
toute opération.
Wichtig:
Allen Sicherheitshinweisen in dieser Broschüre geht eine Zahl voraus. Anhand dieser Zahl kann
die deutsche Übersetzung eines Sicherheitshinweises dem englischen Original bzw. weiteren
Übersetzungen in der Broschüre mit den Sicherheitshinweisen zugeordnet werden.
Geht einem Sicherheitshinweis beispielsweise die Zahl 1 voraus, sind das englische Original und
weitere Übersetzungen in der Broschüre mit den Sicherheitshinweisen unter dieser Nummer zu
finden.
Vor dem Ausführen von Anweisungen unbedingt alle Sicherheitshinweise in dieser Broschüre
lesen.
viii
IBM Netfinity Rack
Fontos:
A könyben szereplő biztonsági utasítások és figyelmeztetések
sorszámot viselnek. Ezek alapján lehet megtalálni egy angol nyelvű
utasítás magyar megfelelőjét a Figyelmeztetések és biztonsági
előírások c. könyvben.
Ha például egy figyelmeztetés az 1-es sorszámot kapta, ennek
fordítása is az 1-es sorszám alatt található az említett könyvben.
Feltétlenül olvassa el a könyvben található valamennyi biztonsági
utasítást és figyelmeztetést, mielőtt hozzálátna az instrukciók
végrehatjtásához !
Importante:
Tutti gli avvisi di ATTENZIONE e PERICOLO presenti in questo manuale iniziano con un numero.
Tale numero contrassegna gli avvisi in lingua inglese e le corrispondenti versioni tradotte che sono
reperibili nell'appropriato opuscolo.
Ad esempio, se un avviso di ATTENZIONE inizia con il numero 1, la corrispondente versione
tradotta è riportata nel suddetto opuscolo come l'avviso numero 1.
Accertarsi di leggere tutti gli avvisi di ATTENZIONE e PERICOLO presenti in questo manuale
prima di eseguire qualunque istruzione.
Danger and Caution References
ix
Важно:
Сите изјави за предупредување и опасност почнуваат со некој
број во оваа книга. Овој број се употребува за поврзување на
англиската изјава за предупредување и опасност со
преведената верзија на истата изјава која може да се најде во
книгата со изјави за предупредување и опасност (Caution and
Danger Information book).
На пример, ако една изјава за предупредување почнува со број
1, преводот на таа изјава се појавува во изјавата со истиот
број 1 во книгата со изјави за предупредување и опасност.
Не заборавете да ги прочитате сите изјави за предупредување
и опасност во оваа книга пред да преминете на извршување на
некоја од инструкциите.
Belangrijk:
Alle waarschuwingen en instructies in dit boek beginnen met een nummer dat telkens
correspondeert met een vertaling van de desbetreffende waarschuwing of instructie in het boek
Caution and Danger Information.
Als voor de instructie bijvoorbeeld het nummer 1 staat, begint de in het boek Caution and Danger
Information opgenomen vertaling van de desbetreffende instructie eveneens met het nummer 1.
x
IBM Netfinity Rack
Lees voordat u een instructie uitvoert, alle waarschuwingen en instructies in dit boek zorgvuldig.
Viktig:
Alle advarselsmerknader (CAUTION) og faremerknader (DANGER) i denne boken begynner med
et nummer. Dette nummeret brukes som kryssreferanse mellom den engelske advarsels- eller
faremerknaden og den oversatte versjonen av merknaden som står i boken Caution and Danger
Information.
Hvis for eksempel en advarselsmerknad begynner med nummer 1, finner du oversettelsen til
denne merknaden i boken Caution and Danger Information under merknad nummer 1.
Du må lese alle advarsels- og faremerknadene i denne boken før du utfører noen av
instruksjonene.
Ważne:
Wszystkie uwagi i ostrzeżenia znajdujące się w tej książce zaopatrzone są w
odpowiednie numery. Numery te używane są do porównania przetłumaczonych
uwag i ostrzeżeń z ich odpowiednikami w języku angielskim, które znajdują się
w książce Caution and Danger Information.
Na przykład, jeżeli ostrzeżenie zaczyna się od numeru 1, jego odpowiednik w
języku angielskim znajduje się w książce Caution and Danger Information pod
numerem 1.
Przed wykonaniem którejkolwiek z instrukcji należy uważnie przeczytać
wszyskie ostrzeżenia i uwagi znajdujące się w tej książce.
Importante:
Todas as notas de cuidado e de perigo, incluídas neste manual, começam por um número. Este
número é utilizado para, a partir de uma nota de cuidado ou perigo, em Inglês, identificar a
respectiva tradução, a qual pode ser encontrada no manual Informações de Cuidado ou Perigo.
Por exemplo, se uma nota de cuidado começa pelo número 1, a respectiva tradução é
apresentada no manual Informações de Cuidado ou Perigo, identificada como nota número 1.
Não deixe de ler todas as notas de cuidado e perigo, incluídas neste manual, antes de executar
qualquer das instruções.
Danger and Caution References
xi
Замечание:
Все замечания, помеченные в данной книге словами "Внимание"
("Caution") и "Опасно" ("Danger"), пронумерованы. По этому
номеру вы сможете найти перевод нужного замечания "Внимание"
или "Опасно" в брошюре Caution and Danger Information (Замечания
с предостережениями и предупреждениями).
Так, если вам нужен перевод замечания "Caution" ("Внимание") под
номером 1, то вы найдете его в брошюре Caution and Danger
Information тоже под номером 1.
Перед тем, как выполнять какие-либо инструкции, обязательно
прочтите все замечания, помеченные в этой книге словами
"Внимание" ("Caution") и "Опасно" ("Danger").
Dôležité:
Všetky upozornenia a výstrahy v tejto publikácii sa začínajú číslom.
Tieto čísla slúžia na prepojenie anglických upozornení a
bezpečnostných poznámok s preloženými verziami upozornení a
bezpečnostných poznámok, nachádzajúcich sa v publikácii
Upozornenia a bezpečnostné poznámky.
Napríklad, keê upozornenie začína číslom 1, preklad tejto poznámky
sa nachádza v publikácii Upozornenia a bezpečnostné poznámky pod
číslom poznámky 1.
Pred vykonaním ktorejkoWvek z inštrukcií, si prečítajte všetky
upozornenia a bezpečnostné poznámky v tejto publikácii.
Pomembno:
Vse previdnostne in nevarnostne navedbe v tej knjigi začnejo s številko. Ta
številka se uporablja za povezavo z angleško previdnostno ali nevarnostno
navedbo, ki jo v prevedeni različici lahko najdemo v knjigi Opozorilne in
nevarnostne informacije.
Če na primer opozorilna navedba začne s številko 1, se prevod te
previdnostne navedbe nahaja v knjigi Opozorilne in nevarnostne informacije
pod števfilko 1.
Prepričajte se, da ste prebrali vse previdnostne in varnostne navedbe v tej
knjigi, preden izvedete katerokoli od navodil.
xii
IBM Netfinity Rack
Importante:
Todos los avisos de precaución y peligro que aparecen en este manual empiezan con un número.
Este número sirve para relacionar la referencia del aviso inglés de precaución o peligro con las
versiones traducidas del aviso de precaución o peligro que pueden encontrarse en el manual de
Información de precaución y peligro
Por ejemplo, si un aviso de precaución empieza con el número 1, las traducciones para ese aviso
de precaución aparecen en el libro de Información de precaución y peligro bajo el aviso número 1.
Asegúrese de leer todos los avisos de precaución y peligro de este manual antes de llevar a cabo
cualquier instrucción.
Viktigt:
Alla varningsmeddelanden i den här boken inleds med ett nummer. Med hjälp av numren kan du
identifiera meddelandenas översättningar som finns i ett eget avsnitt i boken.
Om t ex ett varningsmeddelande har nummer 1 hittar du översättningen av det också som
meddelande nummer 1.
Läs alla varningsmeddelanden i boken, och referera till den svenska översättningen om du inte
förstår originalmeddelandet till fullo.
Danger and Caution References
xiii
About This Book
The information in this book is intended for use by customers and service personnel who plan for, set up,
install, relocate, and maintain the IBM Netfinity Racks.
What This Book Contains
This book provides information about the IBM 9306 Model 900 Netfinity Rack and the IBM 9306 Model
200 Netfinity NetBAY22. It contains a product description, a list of available options, option and equipment
installation guidelines, cable installation guidelines, and a description of the IBM Netfinity Rack
Configurator program. The rack unpacking instructions, the front and rear door removal and installation
instructions, and the side panel removal and installation instructions also are included.
You can use the information in this book to help you:
Ÿ Plan the arrangement and placement of your Netfinity and PC Server systems.
Ÿ Select the options you need for your hardware arrangement.
Ÿ Unpack and set up your rack.
Ÿ Prepare the rack for the installation of your hardware.
Ÿ Understand the guidelines for installing hardware in the rack.
Important
Be sure to keep this book with your rack at all times.
For your convenience, this book and the rack option books are three-hole punched so you can keep them
together in one binder.
xiv
 Copyright IBM Corp. 1998
Product Description
The IBM Netfinity Rack enclosures are industry-standard, 19-inch rack cabinets that provide solutions for
installing and controlling multiple IBM Netfinity and PC Server systems and related equipment. There are
many rack options available to help you to configure the racks for your application.
IBM 9306 Model 900 Netfinity Rack (42-U)
IBM 9306 Model 200 Netfinity NetBAY22 (22-U)
Your IBM Netfinity Rack package contains the following items.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Rack enclosure
Front and rear rack enclosure doors
Two rack side panels (IBM 9306 Model 200 Netfinity NetBAY22 only)
One front stabilizer bracket
Four side stabilizer brackets (IBM 9306 Model 900 Netfinity Rack only)
Twelve stabilizer-bracket mounting bolts (IBM 9306 Model 900 Netfinity Rack only)
Four stabilizer-bracket mounting bolts (IBM 9306 Model 200 Netfinity NetBAY22 only)
Miscellaneous parts kit that includes 4 mm and 5 mm hex keys
Keys for the rack enclosure doors
IBM Netfinity Rack Planning and Installation Guide (this book)
IBM Netfinity Rack Unpacking Instructions
IBM Netfinity Rack Caution and Danger Information book
IBM Safety Information book
The IBM 9306 Model 900 Netfinity Rack has an interior height of 42 U, and will hereafter be called the
42-U rack in this book.
The IBM 9306 Model 200 Netfinity NetBAY22 has an interior height of 22 U, and will hereafter be called
the 22-U rack in this book.
 Copyright IBM Corp. 1998
1
Product Specifications
Ÿ The dimensions (width x depth x height) of the 42-U rack are:
Before Unpacking
After Unpacking
66 cm x 98 cm x 224 cm (26 in. x 38.5 in. x 88 in.)
60 cm x 88 cm x 208 cm (23.5 in. x 34.5 in. x 81.5 in.)
Ÿ The maximum weight of the 42-u rack is 136 kg (300 lbs) empty and 771 kg (1700 lbs) fully loaded.
Ÿ The 42-U rack requires the following clearances:
91.5 cm
(36 in.)
REAR
60 cm
(23.5 in.)
REAR
91.5 cm
(36 in.)
107 cm
(42 in.)
76 cm (30 in.)
61 cm (24 in.)
87.6 cm (34.5 in.)
61 cm (24 in.)
229 cm
(90 in.)
61 cm (24 in.)
74 cm (29 in.)
76 cm (30 in.)
152 cm (60 in.)
FRONT
TOP VIEW
SERVICE CLEARANCE
2
FRONT
TOP VIEW
OPERATIONAL CLEARANCE
 Copyright IBM Corp. 1998
Ÿ The dimensions (width x depth x height) of the 22-U rack are:
Before Unpacking
After Unpacking
66 cm x 98 cm x 137 cm (26 in. x 38.5 in. x 54 in.)
60 cm x 88 cm x 118 cm (23.5 in. x 34.5 in. x 46.5 in.)
Ÿ The maximum weight of the 22-u rack is 82 kg (181 lbs) empty and 424 kg (935 lbs) fully loaded.
Ÿ The 22-U rack requires the following clearances:
91.5 cm
(36 in.)
REAR
60 cm
(23.5 in.)
91.5 cm
(36 in.)
REAR
66 cm
(26 in.)
76 cm (30 in.)
61 cm (24 in.)
30 cm
(12 in.)
87.6 cm (34.5 in.)
229 cm
(90 in.)
61 cm (24 in.)
74 cm (29 in.)
76 cm (30 in.)
152 cm (60 in.)
FRONT
TOP VIEW
SERVICE CLEARANCE
FRONT
TOP VIEW
OPERATIONAL CLEARANCE
Product Specifications
3
Ÿ You need at least 152 cm (60 in.) of space between 42-U rack suites.
This space is necessary for opening the front and rear doors, and for installing and servicing the rack.
It also allows air circulation for cooling the equipment in the rack.
Note: 22-U racks can be installed next to each other, but cannot be attached to form rack suites.
152 cm (60 in.)
The internal dimensions of the rack enclosures conforms to EIA (Electronics Industries Association)
standard 310D for 19-inch racks. The dimensions are shown below.
71.44 cm (28.125 in.)
Inside of front rail to inside of rear rail
46.7 cm (18.4 in.)
45.1 cm (17.75 in.)
46.5 cm (18.3 in.)
49 cm (19.3 in.)
45.1 cm (17.75 in.)
46.5 cm (18.3 in.)
49 cm (19.3 in.)
4
IBM Netfinity Rack
All vertical rack measurements are given in rack units (U). One U is equal to 4.45 cm (1.75 in.). The U
levels are marked on labels on one front mounting rail and one rear mounting rail.
21
20
U Levels
19
Product Specifications
5
Preparing the Physical Site
Before you install a rack enclosure, be sure you:
Ÿ Understand the rack specifications and requirements
Ÿ Prepare a layout for the racks
Ÿ Prepare the physical site
General Planning
Ÿ Determine:
– The size of the floor area required by the equipment (see “Product Specifications” on page 2):
- Floor-load capacity
- Space needed for expansion
- Location of columns
– The power and environmental requirements.
Ÿ Create a floor plan to check for clearance problems.
Ÿ Make a full-scale template (if necessary) of the rack and carry it along the access route to check for
potential clearance problems through doorways and passageways, around corners, and in elevators.
Ÿ Provide space for storage cabinets, card files, desks, communication facilities, daily storage of tapes,
and other supplies.
Ÿ Store all spare materials that can burn in properly designed and protected areas.
Rack Layout
To be sure you have enough space for the racks, create a floor plan before installing the racks. You
might need to prepare and analyze several layouts before choosing the final plan.
If you are installing the racks in two or more stages, prepare a separate layout for each stage.
Consider the following when you make a layout:
Ÿ The flow of work and personnel within the area.
Ÿ Operator access to units, as required.
Ÿ If the rack is on a raised floor, position it over a cooling register. The bottom of the rack is open to
facilitate cooling.
Ÿ If the rack is not on a raised floor:
– The maximum cable lengths
– The need for such things as cable guards and ramps to protect equipment and personnel
Ÿ Location of any planned safety equipment.
Ÿ Expansion.
6
IBM Netfinity Rack
Begin with an accurate drawing of the installation area (blueprints and floor plans are appropriate).
Be sure to include the following on the layout:
Ÿ Service clearances required for each rack or suite of racks.
Ÿ If the equipment is on a raised floor:
– Things that might obstruct cable routing
– The height of the raised floor
Ÿ If the equipment is not on a raised floor:
– The placement of cables to minimize obstruction
– If the cable routing is indirectly between racks (such as along walls or suspended), the amount of
additional cable
Ÿ Location of:
– Power receptacles
– Air conditioning equipment and controls
– File cabinets, desks, and other office equipment
– Room emergency power-off controls
– All entrances, exits, windows, columns, and pillars
Review the final layout to ensure that cable lengths are not too long and that the racks have enough
clearance.
Electrical Requirements
Note: You might need to consult an electrician to assist you with these plans.
Ÿ Each rack requires at least one power unit.
– Refer to “100–120 V Power Distribution Unit (PDU)” on page 13 and “200–240 V Power
Distribution Unit” on page 13 for the power distribution unit (PDU) features.
– Refer to “APC Smart-UPS Uninterruptible Power Supplies” on page 14 for the uninterruptible
power supply (UPS) features.
Ÿ Each power unit (PDU or UPS) requires a separate AC power branch circuit.
Ÿ Make sure the input voltage-selection switch on each device installed in a rack matches the output
voltage of the rack power unit.
Ÿ Make sure the correct power outlets are installed to match your rack power plugs.
Important:
Never change a rack power plug.
Product Specifications
7
Limitations
As you prepare the physical site for the rack enclosure, be aware of the limitations of the rack, especially if
you plan to install non-IBM equipment in the rack. The following requirements reflect some of the
conditions under which the rack and it units were tested for stability and safety. Be sure the rack and its
devices meet these requirements. Failure to meet these requirements might result in an unsafe condition.
1
CAUTION:
To ensure safety, all configurations of the rack must be Listed in the U.S.A. and Certified in
Canada by a nationally recognized testing laboratory such as Underwriters Laboratory (UL),
Canadian Standards Association (CSA), or ETL Testing Laboratories.
Slide Mounted Devices
Some devices mount in the rack on slides. You can extend slide-mounted devices.
2
DANGER
Ÿ The maximum allowable weight for devices mounted on slides is 80 kg (176 lbs). Do
not install sliding devices exceeding this weight.
Ÿ The center of gravity for an extended unit cannot exceed 36.2 cm (14.25 in.) from the
face of the rack. If an extended device exceeds this distance, the configured rack might
be unstable.
8
IBM Netfinity Rack
Center of Gravity of a 42-U Rack
30 cm (11.8 in.)
30 cm (15.3 in.)
TOP VIEW
93.2 cm (36.7 in.)
FRONT VIEW
Center of Gravity of a 22-U Rack
30 cm (11.8 in.)
30 cm (15.3 in.)
TOP VIEW
53.2 cm (20.9 in.)
FRONT VIEW
Product Specifications
9
Stability
The front stabilizer bracket must always be installed on the 42-U rack. Side stabilizer brackets must
always be installed on an individual 42-U rack. Side stabilizer brackets are not required on rack suites of
two or more 42-U racks.
The front stabilizer bracket must always be installed on a 22-U rack. Side stabilizer brackets are not
provided or required on a 22-U rack.
See step 3 on page 28 for stabilizer bracket installation instructions.
Weight Restrictions
The maximum weight of a 42-U rack with installed devices is 771 kg (1700 lbs).
The maximum weight of a 22-U rack with installed devices is 424 kg (935 lbs).
Weight Distribution for Installed Devices
Ÿ The weight of devices that are mounted on the four corner posts must not exceed 14.5 kg (32 lbs) per
rack U level.
Ÿ The weight of cantilevered devices must not exceed 5 kg (11 lbs).
World Wide Web Information
You can obtain up-to-date information about your IBM Netfinity rack, a complete listing of the options that
are supported for you rack, and information about other IBM Netfinity products by accessing the IBM
Intel Processor-based Servers home page at the following address: http://www.pc.ibm.com/us/server
Support information can be found at: http://www.pc.ibm.com/support
Profiling
We will build a customized support page that is specific to your hardware, complete with Frequently Asked
Questions, Parts Information, Technical Hints and Tips, and Downloadable Files when you profile your
IBM products. To profile, go to the support page listed above and select Profile.
10
IBM Netfinity Rack
Available Options
The following options are available for use with the IBM Netfinity Rack.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Fixed Shelf
19-Inch Single-Slide Shelf
Keyboard Tray (with keyboard and mouse extension cables)
Monitor Compartment
Rack Attachment Kit (42-U rack only)
Blank Filler Panel Kit
Side Panel Kit (42-U rack only)
Console Cable Set
Console Server Selector Switches (8-port and 4-port)
100–120 V Power Distribution Unit
200–240 V Power Distribution Unit
APC Smart-UPS 1400 Uninterruptible Power Supply
APC Smart-UPS 3000 Uninterruptible Power Supply
Power Cables
A list of the latest rack options is available from the IBM Personal Computing Solutions World Wide Web
page at http://www.pc.ibm.com/us/accessories/netfinity/rack.html
A description of the options and features follows.
Fixed Shelf
The fixed shelf is capable of supporting 45 kg (100 lbs). The shelf is 44 cm (17.3 in.) wide and 66.5 cm
(26.1 in.) deep. The shelf can be used to support miscellaneous devices or for storage.
19-Inch Single-Slide Shelf
The sliding shelf is a heavy-duty sliding tray designed to support tower-type PC systems. The sliding shelf
is capable of supporting 68 kg (150 lbs). The capacity is one system per shelf. With optional available
mounting plates, the shelf can support the following systems:
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
PC
PC
PC
PC
PC
Server
Server
Server
Server
Server
9585, 9595
300, 320, 325, 330
500, 520
720
3518 Enterprise Expansion Unit
This shelf can also be used with many EIA (Electronics Industries Association) standard 19-inch by
30-inch racks.
 Copyright IBM Corp. 1998
11
Keyboard Tray (with keyboard and mouse extension cables)
The keyboard tray is a sliding tray for a keyboard and a mouse. It can support up to 22.7 kg (50 lbs).
The tray can hold a keyboard that is 50 cm (19.7 in.) wide, 21 cm (8.25 in.) deep, and 3.8 cm (1.5 in.)
high.
A 2.4 m (8 ft) extension cable set is included to connect the keyboard and mouse to the console selector
switch.
Note: The keyboard and monitor can be located on top of a 22-U rack.
Monitor Compartment
The monitor compartment provides space for various monitors. It can support up to 34 kg (75 lbs). The
inside dimensions of the monitor compartment are 44 cm (17.3 in.) wide and 43 cm (17 in.) deep. Space
is provided behind the monitor compartment for the console selector switch.
For convenient viewing, install the monitor compartment at the top of the rack.
Note: The keyboard and monitor can be located on top of a 22-U rack.
Rack Attachment Kit (IBM 9306 Model 900 Netfinity Rack Only)
The rack attachment kit provides brackets, screws, and trim to connect two racks together into a suite. An
additional rack attachment kit is required for each additional rack added to the suite.
Blank Filler Panel Kit
The blank filler panel kit provides two 1U panels, one 3U panel, and one 5U panel.
Note: All vertical rack measurements are given in rack units (U). One U is equal to 4.45 cm (1.75 in.).
The panels are used to cover unused mounting space in a rack.
Side Panel Kit (IBM 9306 Model 900 Netfinity Rack Only)
This option consists of two locking side panels. One side panel kit is required for each stand-alone rack
or multi-rack suite.
Console Cable Set
This cable set connects a mouse, keyboard, and monitor to the console server selector switch. The video
cable supports VGA and SVGA.
12
IBM Netfinity Rack
Console Server Selector Switch
There are two models of the console server selector switch. Depending on the model, the selector switch
connects up to four servers, or up to eight servers to a single console. The switch functions through a
keyboard and on-screen configuration control.
Refer to the IBM Netfinity Rack Console Server Selector Switch User's Guide and Installation Instructions
for detailed information.
100–120 V Power Distribution Unit (PDU)
This PDU has the following features:
Ÿ Eight National Electrical Manufacturers Association (NEMA)-15R power outlets
Ÿ A fixed 2.7 m (9 ft) power cable with a NEMA L5-15P locking plug
Ÿ A 15 amp circuit breaker
Ÿ A maximum current rating of 12 amps by Underwriters Laboratory (UL) standards
Ÿ A maximum power rating of 1440 volt amperes (VA)
Ÿ Electromagnetic Interference/Radio Frequency Interference (EMI/RFI) filtering for common mode noise
(line to ground) and differential mode noise (line to line)
Ÿ A spike and surge suppression circuit to protect the line
The PDU is 48 cm (19 in.) wide x 4.5 cm (1.75 in.) high x 11.5 cm (4.5 in.) deep and weighs 2.27 kg (5
lbs). The PDU can be installed horizontally in one EIA U space, or vertically in the rack side wall.
200–240 V Power Distribution Unit
This PDU has the following features:
Ÿ Ten International Electrotechnical Commission (IEC) 320-C13 outlets
Ÿ A maximum current rating of 16 amps by Verband Deutscher Elektrotechniker (VDE) standards
Ÿ A maximum power rating of 3200 VA
Ÿ A panel mount IEC 320-C20 inlet (16 amps/230 V ac) standard connector
Ÿ A detachable power cable with a NEMA L6-20P plug (country specific)
Ÿ Ten IEC outlets rated at 10 amps (VDE) or 15 amps (UL/CSA)
– Eight outlets on the rear panel
– Two outlets on the front panel
Ÿ Conforms to UL1950, Canadian Standards Association (CSA) 22.0-950, and IEC 950
Ÿ A 2-pole, 20 amp circuit breaker with time-delay protection; that supports input currents of up to 600
amps without nuisance tripping
Ÿ EMI/RFI filtering for common noise (line to ground) and differential mode noise (line to line)
Ÿ A spike and surge suppression circuit to protect the line
The PDU is 48 cm (19 in.) wide x 4.5 cm (1.75 in.) high x 17.8 cm (7 in.) deep and weighs 3.63 kg (8 lbs).
The PDU can be installed horizontally in one EIA U space, or vertically in the rack side wall.
Available Options
13
APC Smart-UPS Uninterruptible Power Supplies
The APC Smart-UPS power supplies are high-performance, line-interactive, uninterruptible power supplies
designed to provide reliable AC power to server systems.
Standard features include:
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Sine wave output for compatibility with all loads
EMI/RFI filtering to eliminate line noise
SmartBoost to automatically correct brownouts
SmartTrim to automatically correct overvoltages
UL 1449 rated for maximum surge suppression
UL listed, CSA certified, VDE certified, FCC Class B compliant
SmartSlot for customization of UPS (contact APC)
Automatic self-testing of battery failure with notification of failure
Site wiring fault indicator
Resettable input circuit breaker for equipment protection
Emergency power off cable for user-provided emergency power-off switch
Easy battery replacement (kits available from APC)
Power management software (APC PowerChute Plus)
Smart-UPS 1400 for IBM
Ÿ Provides 1400 volt amperes or 950 watts
Ÿ Communicates with one server
Ÿ Contains four 12 V, 7 ampere-hour batteries
The UPS is 48 cm (19 in.) wide x 13.2 cm (5.2 in.) high x 38 cm (15 in.) deep and weighs 25 kg (55 lbs).
There are two versions of this UPS:
Ÿ Model 1400RMB
–
–
–
–
120 V ac
Six NEMA 5-15R receptacles
Fixed 1.8 m (6 ft) power cable with a NEMA L5-15P plug
Resettable 15 amp circuit breaker
Ÿ Model 1400RMiB
–
–
–
–
220–240 V ac
Four IEC 320-C13 receptacles
IEC 320-C14 connector for a detachable power cable (country specific)
Resettable 12 amp circuit breaker
Smart-UPS 3000 for IBM
Ÿ Provides 3000 volt amperes or 2250 watts
Ÿ Communicates with three servers
Ÿ Contains eight 12 V, 7 ampere-hour batteries
The UPS is 48 cm (19 in.) wide x 13.2 cm (5.2 in.) high x 61 cm (24 in.) deep and weighs 51 kg (112
lbs).
14
IBM Netfinity Rack
There are two versions of this UPS:
Ÿ Model 3000RMB
–
–
–
–
120 V ac
Eight NEMA 5-15R receptacles
Fixed 1.8 m (6 ft) power cable with a NEMA L5-30P plug
Resettable 40 amp circuit breaker
Ÿ Model 3000RMiB
–
–
–
–
220–240 V ac
Eight IEC 320-C14 and one IEC 320-C19 receptacle
IEC 320-C20 connector for a detachable power cable (country specific)
Resettable 20 amp circuit breaker
APC PowerChute Plus Power Management Software
Ÿ
Ÿ
Ÿ
Ÿ
Provided with IBM Netfinity and PC Servers on IBM ServerGuide
Monitors voltages, loads, runtime, and so on through IBM NetFinity
Manages automatic software alerts and orderly server shutdowns
Compatible with Microsoft Windows NT, OS/2 Warp, Novell Netware, Santa Cruz Operation, Inc.
operating systems
Power Cables
These optional power cables are available to connect IBM Netfinity and PC Servers and other devices to a
PDU or UPS in a Netfinity Rack when longer power cables are required.
Ÿ Power Cable Type A14
– Connectors: IEC 320 C13-NEMA 5-15P
– Length: 4.3 m (14 ft)
– Used with: 100–120 V ac PDU or 120 V ac UPS
Ÿ Power Cable Type B14
– Connectors: IEC 320 C19-NEMA 5-15P
– Length: 4.3 m (14 ft)
– Used with: 100–120 V ac PDU or 120 V ac UPS
Ÿ Power Cable Type C12
– Connectors: IEC 320 C13-C14
– Length: 3.7 m (12 ft)
– Used with: 200–240 V ac PDU or 220–240 V ac UPS
Ÿ Power Cable Type D12
– Connectors: IEC 320 C19-C14
– Length: 3.7 m (12 ft)
– Used with: 200–240 V ac PDU or 220–240 V ac UPS
Available Options
15
IBM Netfinity Rack Configurator Program
The IBM Netfinity Rack Configurator program is a stand-alone program used to configure and validate
Netfinity Rack systems. The configurator program provides an intuitive, user-friendly, graphical interface to
help you configure the Netfinity Rack system.
You can use the configurator program to obtain the following information:
Ÿ Weight and stability limits
Ÿ Thermal and heat calculations
Ÿ Power requirements
Ÿ Internal space dimensions
Ÿ External space requirements
Ÿ Human factor considerations
You select components from the Component Catalog, and place them in the Picture of the Configuration
Notebook to create your configuration. The Configuration Notebook also contains a Parts List,
Specifications, and a top-view Floor Plan.
You can configure a single rack, a suite of racks, or a collection of suites, using functions such as Auto
Arrange, Validate, and Build for proper placement of components. You can then connect components and
select the appropriate cables for connection.
You can identify components as installed then create NetFinity files to assist in system management.
For additional assistance in creating your configuration, you can start IBM ConfigPro or IBM Which
Switch? to configure individual components.
You can obtain a copy of the IBM Netfinity Rack Configurator program from either of the following:
Ÿ IBM Personal Computing Solutions World Wide Web page at
http://www.us.pc.ibm.com/products/netfinity/netfinity_products.html
Ÿ IBM PC Company Bulletin Board Service (BBS) at (919) 517-0001
16
 Copyright IBM Corp. 1998
Rack Option and Equipment Installation Guidelines
Follow these guidelines when installing options and equipment in the rack.
3
IBM 9306 Model 200 Netfinity NetBAY22 (22-U)
DANGER
Ÿ Always install servers and power devices in the rack from the bottom to the top.
Ÿ Always install the heaviest equipment in the bottom of the rack.
Ÿ Always install the UPS (uninterruptible power supply) in the bottom of the rack.
Ÿ Always install the stabilizer bracket.
Ÿ Do not extend more than one sliding device at a time.
3
IBM 9306 Model 900 Netfinity Rack (42-U)
DANGER
Ÿ Always install servers and power devices in the rack from the bottom to the top.
Ÿ Always install the heaviest equipment in the bottom of the rack.
Ÿ Always install the UPS (uninterruptible power supply) in the bottom of the rack.
Ÿ Always install the front stabilizer bracket. Side stabilizer brackets are not required on
suites of two or more racks.
Ÿ Do not extend more than one sliding device at a time.
Ÿ Install the keyboard tray, monitor housing, and shelves before installing servers and power devices.
Ÿ Install the monitor compartment and monitor at the top of the rack.
Ÿ When connecting racks together to form rack suites (42-U racks only), connect the racks together
before installing equipment in the racks, if possible.
Ÿ Do not place anything on top of a 42-U rack. The exhaust vents must not be blocked.
The keyboard and monitor can be located on top of a 22-U rack.
Ÿ Route power cables so that they enter and exit through the rack bottom. Power cables cannot be
routed through the front or rear door openings.
Ÿ When installing an IBM PC Server 325 in the rack, always remove the PC Server 325 front door. The
server front door might hinder server cooling. The rack’s locking front door provides the necessary
security for the server.
 Copyright IBM Corp. 1998
17
4
DANGER
Plug rack power cables into electrical outlets that are located near the rack and are easily
accessible.
5
DANGER
Each rack might have more than one power cord. Be sure to disconnect all power cords in
the rack before servicing any device in the rack.
6
DANGER
Install an emergency power off (EPO) switch if more than one power device (power
distribution unit or uninterruptible power supply) is installed in one rack.
7
DANGER
Connect all devices installed in a rack to power devices installed in the same rack. Do not
plug the power cord from a device installed in one rack into a power device installed in a
different rack.
18
IBM Netfinity Rack
Netfinity Rack Cables Installation Guidelines
Follow these guidelines when installing rack cables.
Ÿ When installing cables to devices mounted on sliding rails:
– Run the cables neatly along equipment cable-management arms and tie the cables to the arms.
(Obtain the cable ties locally.)
– Leave enough slack so the device can be fully extended without putting a strain on the cables.
– Tie the cables so the device can be retracted without pinching or cutting the cables.
Ÿ Run the cables neatly along the rack rear corner posts.
Ÿ Use cable ties to secure the cables to the corner posts.
Ÿ Make sure the cables cannot be pinched or cut by the rack rear door.
Ÿ Run internal cables that connect devices in adjoining racks through the open rack sides.
Ÿ Run external cables through the open rack bottom.
Ÿ Take particular care when attaching fiber optic cables to the rack. Refer to the instructions included
with your fiber optic cables for guidance on minimum radius, handling, and care of fiber optic cables.
Ÿ As you install cables in the rack, label each cable with appropriate identification.
The figure on the following page shows examples of how to install and tie the cables in a 9306 Model 900
two rack suite.
Note: Dotted lines indicate hidden cables.
 Copyright IBM Corp. 1998
19
One
Reset
Aux.
20
IBM Netfinity Rack
K
M
Two
K
M
Three
K
M
Two
K
M
Three
K
M
Three
K
M
Two
K
M
Three
K
M
Important
Information
Example of Cable Routing in a 9306 Model 900 Two Rack Suite
1
0
Calculating Cable Lengths in One 9306 Model 900 Rack
9306-900
42u
42u = 1.867m (6ft 1.5in.)
server/
storage/
etc. slide
out for
service
1.83m
(6 ft.)
107cm (42 in.)
30cm
(12 in.)
30cm (12 in.)
to
60cm (24 in.)
UPS
71cm
(28 in.
device
depth)
Examples:
Power Cables
(device must be plugged into power unit in the same rack)
Drawer (on slides) just above UPS
Drawer (on slides) top of rack to UPS at bottom
1.7 to 2 m (5.5 to 6.5 ft)
3.5 m (11.5 ft)
SSA or SCSI Cables
On Slides
Bolt In
Storage unit just above server drawer
Storage unit at top of rack, server at bottom
Storage unit in adjacent rack
Storage unit in rack, server in another rack,
N racks between
if N=1 then
if N=2 then
2.4 m (8 ft)
4 m (13 ft)
4 m (13 ft)
13 + (Nx2)
2 m (6.6 ft)
3.5 m (11.5 ft)
3.5 m (11.5 ft)
11.5 + (Nx2)
4.6 m (15 ft)
5.2 m (17 ft)
4.1 m (13.5 ft)
4.7 m (15.5 ft)
Netfinity Rack Cables Installation Guidelines
21
Calculating Cable Lengths in a 9306 Model 900 Four Rack Suite
Console
Cable
30cm (12 in.)
to
60cm (24 in.)
Storage
Unit
SSA
Cable
30cm
(12 in.)
107cm
(42 in.)
Server
Selector
Switch
Server
D
C
SSA
Cable
30cm (1 ft)
to
1.8m (6 ft)
IBM Netfinity Rack
Console
Cable
30cm (12 in.)
to
60cm (24 in.)
Selector
Switch
Storage
Unit
Server
22
B
A
Server
Examples:
Power Cables (device must be plugged into power unit in the same rack)
Refer to “Calculating Cable Lengths in One 9306 Model 900 Rack” on page 21 for power cable calculation
examples.
SSA or SCSI Cables
On Slides
Bolt In
Storage unit in rack, server in another rack,
N racks between
if N=1 then
if N=2 then
13 + (Nx2)
11.5 + (Nx2)
4.6 m (15 ft)
5.2 m (17 ft)
4.1 m (13.5 ft)
4.7 m (15.5 ft)
Console Server Selector Switch Cables
Server in rack, selector switch in another rack, N racks between
if N=0 then
if N=1 then
if N=2 then
if N=3 then
3.5 + 1 + (1 to 6) + ( 1 to 2) + (Nx2)
2 m (6.5 ft) to 3.8 m (12.5 ft)
2.6 m (8.5 ft) to 4.4 m (14.5 ft)
3.2 m (10.5 ft) to 5 m (16.5 ft)
3.8 m (12.5 ft) to 5.6 m (18.5 ft)
Calculating Cable Lengths in a 9306 Model 200 NetBAY22
NetBAY22 22u
22u = 97.8cm (38.5in.)
107cm (42 in.)
91.5cm
(3 ft.)
60cm (24 in.)
UPS
71cm
(28 in.
device
depth)
Examples:
Power Cables
Drawer (on slides) just above UPS
Drawer (on slides) top of rack to UPS at bottom
1.7 to 2 m (5.5 to 6.5 ft)
2.6 m (8.5 ft)
SSA or SCSI Cables
On Slides
Bolt In
Storage unit just above server drawer
Storage unit at top of rack, server at bottom
2.4 m (8 ft)
3 m (10 ft)
2 m (6.6 ft)
2.6 m (8.5 ft)
Netfinity Rack Cables Installation Guidelines
23
Rack Relocation Safety Guidelines
8
DANGER
A fully loaded rack can weigh up to 771 kg (1700 lbs). A fully loaded rack can be relocated
(rolled on the casters) within a room or building.
Take the following precautions before relocating a loaded rack.
Ÿ Reduce the weight of the rack by removing equipment, if possible.
Ÿ Inspect the route you plan to take and eliminate potential hazards.
Ÿ Verify that the route you have chosen can support the weight of the loaded rack.
Ÿ The rack can be rolled through a standard 76 cm (30 in.) by 219 cm (83 in.) door
opening.
Ÿ A minimum of two trained moving or relocation personnel must be used to relocate a
loaded rack (one person behind the rack and one person in front of the rack).
Ÿ Make sure all devices, drawers, doors, and cables are secure.
Ÿ Make sure the four leveling pads are raised to their highest position.
Ÿ Make sure the stabilizer bracket is removed.
Ÿ Do not use a ramp inclined at more than ten degrees.
A long distance relocation requires the following additional precautions.
Ÿ Remove heavy equipment (servers, UPS) from the rack.
Ÿ Pack the rack in appropriate packaging material.
24
 Copyright IBM Corp. 1998
Unpacking the Netfinity Rack
The rack unpacking instructions are contained in a pouch on the outside of the rack packing material.
They are included here also for your convenience. Follow these instructions to unpack the rack.
9
IBM 9306 Model 200 Netfinity NetBAY22 (22-U)
DANGER
The empty rack weighs 82 Kg (181 lbs). Two or more people are required to complete this
procedure.
9
IBM 9306 Model 900 Netfinity Rack (42-U)
DANGER
The empty rack weighs 136 Kg (300 lbs). Two or more people are required to complete this
procedure.
You will need the following items to unpack the rack:
Ÿ Utility knife
Ÿ 5 mm hex key (provided in the miscellaneous parts kit that comes with the rack)
Ÿ 12 mm open-end wrench
 Copyright IBM Corp. 1998
25
Removing the Packaging Materials
IBM 9306 Model 900 Netfinity Rack (42-U)
1.
2.
3.
4.
5.
6.
26
IBM 9306 Model 200 Netfinity NetBAY22 (22-U)
Use a utility knife to cut the plastic bands.
Use a utility knife to remove the outer plastic wrap. Cut the plastic wrap at the “CUT HERE” mark.
Remove the plastic wrap, the cardboard top cover, and the four cardboard corner protectors.
Remove the plywood shipping board from the top (22-U rack only).
Remove the plastic bag.
Remove the box containing the stabilizer brackets and screws from the top of the pallet.
IBM Netfinity Rack
Removing the Rack from the Shipping Pallet
1. Lift the retaining board at the rear of the pallet from its slots. This allows the rack to be rolled off the
pallet.
2. With one person on each side of the rack, carefully roll the rack toward the rear of the pallet until the
rear casters are off the pallet.
3. Continue to slide the rack off the pallet until the rear casters touch the floor and the front rack casters
are off the pallet. Carefully ease the rack off the pallet.
Unpacking the Netfinity Rack
27
Locating the Rack
1. Roll the rack to the location you selected for installation.
2. Use the 12 mm open-end wrench to lower the four leveling pads until they make firm contact with the
floor.
3. Install the front stabilizer bracket.
Note: The front stabilizer bracket installation is required on both single and multi-rack suite
installations.
a. Place the front stabilizer bracket so the holes in the vertical flange line up with the threaded holes
in the rack.
b. Thread four screws into the threaded holes.
c. Make sure the front stabilizer is flat against the floor.
d. Tighten the screws.
e. Screw the front stabilizer bracket to the floor, if desired, or install the four stabilizer bracket plugs.
28
IBM Netfinity Rack
4. Install the side stabilizer brackets (42-U racks only).
Note: Side stabilizer brackets are not required on rack suites of two or more racks.
a. Position two side stabilizer brackets on each side of the rack.
Instead of installing all four side stabilizer brackets on the outside of the rack, two side stabilizer
brackets can be installed inside the rack as shown below.
Note: The two side stabilizer brackets inside the rack must be screwed to the floor.
b. Thread two screws through each side stabilizer bracket into the rack.
c. Tighten the screws.
d. The four outside side stabilizer brackets can be screwed to the floor, if desired.
Your rack is now in position and secure. You are now ready to:
Ÿ Connect additional racks to form a suite of racks.
Ÿ Install servers and options.
Unpacking the Netfinity Rack
29
Removing and Installing the Front and Rear Doors
Follow this procedure to remove the front or rear door.
1. If the door is locked, unlock it.
Locked
Unlocked
2. Open the door.
3. While supporting the door, remove the hinge pins.
4. Remove the door and carefully set the door aside.
Follow this procedure to install the front or rear door.
1. While supporting the door, line up the door hinges with the rack hinges.
2. Insert the hinge pins.
3. Close and lock the door.
30
 Copyright IBM Corp. 1998
Netfinity Rack Side Panel Kit Removal and Installation
Follow these instructions to remove the side panel.
1. If the side panel is locked, unlock it.
Locked
Unlocked
2. Slide the two side-panel latches down to release the top of the side panel.
3. Tilt the top of the side panel away from the rack and lift the side panel off the rack.
 Copyright IBM Corp. 1998
31
Follow these instructions to install the side panel.
1. Lift the side panel onto the rack mounting rail.
2. Push the top of the side panel against the rack until the side-panel latches snap, securing the side
panel to the rack.
3. Lock the side panel if desired.
Locked
32
Unlocked
IBM Netfinity Rack
Removing and Installing the Horizontal Side Braces
The horizontal side braces can be relocated within the rack. Follow this procedure to remove the side
brace.
1. Remove the side panel from the rack.
2. Compress the small plastic clip at the front end of the side brace and remove the clip. Save the clip.
3. Lift the side brace up to disengage it from the vertical mounting rails.
4. Slide the side brace toward the rear of the rack and out of the front vertical mounting rail.
5. Slide the side brace toward the front of the rack and remove it from the rear vertical mounting rail.
Follow this procedure to reinstall the side brace.
1. Insert the rear of the side brace into the holes in the rear vertical mounting rail.
2. Insert the front of the side brace into the holes in the front vertical mounting rail.
3. Make sure the ends of the side brace are installed at the same level in both vertical mounting rails.
4. Push the side brace down to latch the ends of the side brace into the vertical mounting rails.
5. Insert the small plastic clip into the front end of the side brace until it snaps in place.
6. Reinstall the rack side panel.
 Copyright IBM Corp. 1998
33
Appendix A. Help and Service Information
During the warranty period, you can get toll-free technical support 24 hours a day, 7 days a week*, to
answer any questions about your Netfinity Rack (toll-free technical support is available in the United States
only). If you need warranty service, return or exchange is available. In addition, you might be entitled to
service at your location. Your technical support representative can help you determine the best
alternative.
Before calling, please prepare for your call by following these steps.
Step 1: Troubleshooting
Before calling IBM, you might want to try some or all of the following troubleshooting procedures.
1. Remove and reattach all cables.
2. Reread any software instructions; be sure software settings are correct.
3. After completing these steps, reassemble the Netfinity Rack and connect the power cord.
Step 2: Preparing for the Service Call
To assist the technical support representative, have the following information available:
1. Option name, description, and serial number
2. Proof of purchase
3. Server model, serial number, and manual
4. Exact wording of the error message (if any)
5. Description of the problem
6. Hardware and software configuration information for your system
If possible, be at your computer. Your technical support representative might want to walk you through
the problem during the call.
Step 3: Placing the Service Call to IBM
Use one of the following numbers:
Ÿ In the United States and Puerto Rico, call 1-800-772-2227.
Ÿ In Canada, call 1-800-565-3344.
Ÿ In all other Countries, contact your IBM reseller, IBM marketing representative, or your place of
purchase.
*
Response time will vary depending on the number and nature of calls received.
34
 Copyright IBM Corp. 1998
Appendix B. Product Warranties and Notices
The following is the statement of limited warranty for the United States, Canada, and Puerto Rico.
International Business Machines Corporation
Armonk, New York, 10504
Statement of Limited Warranty
The warranties provided by IBM in this Statement of Limited Warranty apply only to Machines you originally purchase for your use,
and not for resale, from IBM or your reseller. The term “Machine” means an IBM machine, its features, conversions, upgrades,
elements, or accessories, or any combination of them. Unless IBM specifies otherwise, the following warranties apply only in the
country where you acquire the Machine. If you have any questions, contact IBM or your reseller.
Machine: IBM Netfinity Rack
Warranty Period*: Three Years
*Contact your place of purchase for warranty service information.
Production Status
Each Machine is manufactured from new parts, or new and used parts. In some cases, the Machine may not be new and may have
been previously installed. Regardless of the Machine's production status, IBM's warranty terms apply.
The IBM Warranty for Machines
IBM warrants that each Machine 1) is free from defects in materials and workmanship and 2) conforms to IBM's Official Published
Specifications. The warranty period for a Machine is a specified, fixed period commencing on its Date of Installation. The date on
your receipt is the Date of Installation, unless IBM or your reseller informs you otherwise.
During the warranty period IBM or your reseller, if authorized by IBM, will provide warranty service under the type of service
designated for the Machine and will manage and install engineering changes that apply to the Machine.
For IBM or your reseller to provide warranty service for a feature, conversion, or upgrade, IBM or your reseller may require that the
Machine on which it is installed be 1) for certain Machines, the designated, serial-numbered Machine and 2) at an
engineering-change level compatible with the feature, conversion, or upgrade. Many of these transactions involve the removal of
parts and their return to IBM. You represent that all removed parts are genuine and unaltered. A part that replaces a removed part
will assume the warranty service status of the replaced part.
If a Machine does not function as warranted during the warranty period, IBM or your reseller will repair it or replace it with one that is
at least functionally equivalent, without charge. The replacement may not be new, but will be in good working order. If IBM or your
reseller is unable to repair or replace the Machine, you may return it to your place of purchase and your money will be refunded.
If you transfer a Machine to another user, warranty service is available to that user for the remainder of the warranty period. You
should give your proof of purchase and this Statement to that user. However, for Machines which have a life-time warranty, this
warranty is not transferable.
Warranty Service
To obtain warranty service for the Machine, you should contact your reseller or call IBM. In the United States, call IBM at
1-800-772-2227. In Canada, call IBM at 1-800-565-3344. You may be required to present proof of purchase.
IBM or your reseller will provide certain types of repair and exchange service, either at your location or at IBM's or your reseller's
service center, to restore a Machine to good working order.
When a type of service involves the exchange of a Machine or part, the item IBM or your reseller replaces becomes its property and
the replacement becomes yours. You represent that all removed items are genuine and unaltered. The replacement may not be
new, but will be in good working order and at least functionally equivalent to the item replaced. The replacement assumes the
warranty service status of the replaced item. Before IBM or your reseller exchanges a Machine or part, you agree to remove all
features, parts, options, alterations, and attachments not under warranty service. You also agree to ensure that the Machine is free
of any legal obligations or restrictions that prevent its exchange.
You agree to:
1. obtain authorization from the owner to have IBM or your reseller service a Machine that you do not own; and
2. where applicable, before service is provided —
a. follow the problem determination, problem analysis, and service request procedures that IBM or your reseller provide,
b. secure all programs, data, and funds contained in a Machine, and
 Copyright IBM Corp. 1998
35
c. inform IBM or your reseller of changes in a Machine's location.
IBM is responsible for loss of, or damage to, your Machine while it is 1) in IBM's possession or 2) in transit in those cases where IBM
is responsible for the transportation charges.
Extent of Warranty
IBM does not warrant uninterrupted or error-free operation of a Machine.
The warranties may be voided by misuse, accident, modification, unsuitable physical or operating environment, improper
maintenance by you, removal or alteration of Machine or parts identification labels, or failure caused by a product for which IBM is
not responsible.
THESE WARRANTIES REPLACE ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. THESE WARRANTIES GIVE YOU SPECIFIC LEGAL RIGHTS AND
YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION. SOME
JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF EXPRESS OR IMPLIED WARRANTIES,
SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU. IN THAT EVENT SUCH WARRANTIES
ARE LIMITED IN DURATION TO THE WARRANTY PERIOD. NO WARRANTIES APPLY AFTER THAT PERIOD.
Limitation of Liability
Circumstances may arise where, because of a default on IBM's part or other liability you are entitled to recover damages from IBM.
In each such instance, regardless of the basis on which you are entitled to claim damages from IBM (including fundamental breach,
negligence, misrepresentation, or other contract or tort claim), IBM is liable only for:
1. damages for bodily injury (including death) and damage to real property and tangible personal property; and
2. the amount of any other actual direct damages or loss, up to the greater of U.S. $100,000 or the charges (if recurring, 12
months' charges apply) for the Machine that is the subject of the claim.
UNDER NO CIRCUMSTANCES IS IBM LIABLE FOR ANY OF THE FOLLOWING: 1) THIRD-PARTY CLAIMS
AGAINST YOU FOR LOSSES OR DAMAGES (OTHER THAN THOSE UNDER THE FIRST ITEM LISTED ABOVE);
2) LOSS OF, OR DAMAGE TO, YOUR RECORDS OR DATA; OR 3) SPECIAL, INCIDENTAL, OR INDIRECT
DAMAGES OR FOR ANY ECONOMIC CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS OR SAVINGS),
EVEN IF IBM OR YOUR RESELLER IS INFORMED OF THEIR POSSIBILITY. SOME JURISDICTIONS DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU.
36
IBM Netfinity Rack
Notices
References in this publication to IBM products, programs, or services do not imply that IBM intends to
make these available in all countries in which IBM operates. Any reference to an IBM product, program,
or service is not intended to state or imply that only that IBM product, program, or service may be used.
Subject to IBM’s valid intellectual property or other legally protectable rights, any functionally equivalent
product, program, or service may be used instead of the IBM product, program, or service. The evaluation
and verification of operation in conjunction with other products, except those expressly designated by IBM,
are the responsibility of the user.
IBM may have patents or pending patent applications covering subject matter in this document. The
furnishing of this document does not give you any license to these patents. You can send license
inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
500 Columbus Avenue
Thornwood, NY 10594
U.S.A.
Trademarks
The following terms are trademarks of the IBM Corporation in the United States or other countries or both:
IBM
NetBAY
NetFinity
OS/2
Intel is a trademark of Intel Corporation in the United States and/or other countries.
Other company, product, and service names may be trademarks or service marks of others.
Appendix B. Product Warranties and Notices
37
IBM

Part Number: 24L8055
Printed in U.S.A.
24L8ð55
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF