MSTronic Co., Ltd.
MSTronic Co., Ltd.
2F, 12, Gongshang Rd., Wugu District, New Taipei City, 248 Taiwan
TEL:886-2-2293-0159
FAX:886-2-2292-8851
E.MAIL: [email protected]
WEB: http://www.mse.com.tw
MIT-09G-56H
21-2002
Gigabit PoE Injector
1. INPUT :
1.1 Input Voltage:
1.2 Input Frequency :
1.3 Input Current:
1.4 Inrush current:
2. OUTPUT :
2.1 Output Voltage & Current:
AC 90V ~ 264V @120V/230V
47 ~ 63hz
1.02A at 120Vac @F.L
0.63A at 230Vac
25A Max at 120Vac & 50A Max at 230Vac
OUTPUT
Max.
load
+56V
0.9A
Power
50.4W Max
Min. Load
0A
Load reg. %
5%
Line reg. %
1%
Ripple %
1%
Noise %
2%
TOTAL POWER :50.4 W
Note 1: Ripple & Noise bandwidth is from DC to 20Mhz. Terminated With a
47uF Capacitor and 0.1uf MPE Capacitor of Proper Polarity.
3.
EFFICIENCY : 85% min. at AC 120V Input @F.L
4.
PROTECTION
4.1 Short Circuit Protection
Output Short GND Terminal will not damage the Power Supply will AutoRecover when Load status going to normally.
4.2 Over Voltage Protection : 59V ~ 65V
4.3 Over Current Limits : 150% ~ 200% @90V ~ 240Vac
4.4 Input with Fuse Protection
4.5 LED indicates PWR - OK
5.
EMC : Meet FCC Class B EN55022 Class B
5.1 SAFETY STANDARD : Meet UL1950, CSA 22.2 &TUV EN60950
5.2 Hold up time :6mS min. at maximum load &120Vac Input.
MSTronic Co., Ltd.
2F, 12, Gongshang Rd., Wugu District, New Taipei City, 248 Taiwan
TEL:886-2-2293-0159
FAX:886-2-2292-8851
E.MAIL: [email protected]
WEB: http://www.mse.com.tw
6.
6.1
6.2
6.3
6.4
6.5
GENERAL DESCRIPTION
Operation Temperature:
Storage Temperature:
Operation Humidity:
Cooling:
SIZE
-40 - +70 °C
-40 - +85 °C
5% - 90%RH (non-condensing)
Free air cooling
125*72*38 (L*W*H)
[email protected]
tel: 08-52400700
MSTronic Co., Ltd.
2F, 12, Gongshang Rd., Wugu District, New Taipei City, 248 Taiwan
TEL:886-2-2293-0159
FAX:886-2-2292-8851
E.MAIL: [email protected]
WEB: http://www.mse.com.tw
7..1 RJ45 pin assignment: @1000MBASE
RJ-45 Input (Data Only)
RJ-45 Output (Data & Power)
Pin
Symbol
Description
Symbol
Description
1
BI_DA+
Data Pair A+
BI_DA+
Data Pair A+
2
BI_DA-
Data Pair A-
BI_DA-
Data Pair A-
3
BI_DB+
Data Pair B+
BI_DB+
Data Pair B+
4
BI_DC+
Data Pair C+
+Vdc + BI_DC+
power(+)+Data Pair C+
5
BI_DC-
Data Pair C-
+Vdc + BI_DC-
power(+)+Data Pair C-
6
BI_DB-
Data Pair B-
BI_DB-
Data Pair B-
7
BI_DD+
Data Pair D+
-Vdc + BI_DD+
power(-)+Data Pair D+
8
BI_DD-
Data Pair D-
-Vdc + BI_DD-
power(-)+Data Pair D-
S
Shield
Shield
Shield
Shield
7.2 the input and output RJ45s with metal enclosure for shield, connected to FG.
SURGE/LIGHTNING PROTECTION
2
5
BR1
R1
750K
C2
222
Y2
1206
1206
V+
AC
V-
4
C20
3
474/300V
R2
750K
AC
+
103/1KV
C1
ZP1
AC 90 ~ 264V 7D471
C5
GBU406
1
2
F1
AC/L
T50-26B
C
D1
A
G
O.V.P
R14
10K
ZD2
20V
D2
LB1
2
1
301A
BYD57ZD
CR1
SCR
C18
104
BYD57ZK
B3
RH4*2*3
R13
Q1
MPF09N60
+
C7
47UF/50V
10R
1206
T1C
H3
C23
102/2KV
B
D4
U1
5
1
2
4
CD4148
GND
GATE
FB
VDD
RI
SENSE
8
7
6
4
C8
103
PL1B
PC817
1
R4
R6
750K 470K
1206 1206
FG
A
D
T1A
103/1KV
T2A/250V 10D005
6
C6
R5
470K
1206
KXG
NTC1
C19
332
Y
B
R7
100K 100K
2010 2010
K
AC/L
R8
R3
470K
1206
18*26
C3
222
Y2
C
L5
T1
3
2
T50-26B
C4
332
Y2
6
PQ2625
EE25 30mH
L1
L4
AC/N
D
4
1
AC/N
3
68U/450V
1
R12 47R
C10
332
R10
R15
47K
1K
R9 LD7552B
100K
3
C9
470P
R11
R16
0.75R
2512
0.75R
A
2512
C11
222/250V
Y1
1
ZP1 : 7D471
2
3
4
5
6
MSTronic Co., Ltd.
2F, 12, Gongshang Rd., Wugu District, New Taipei City, 248 Taiwan
TEL:886-2-2293-0159
FAX:886-2-2292-8851
E.MAIL: [email protected]
WEB: http://www.mse.com.tw
1
2
3
4
5
6
D
D
S2
AC/N
S1
3
BR1
R1
750K
C2
222
Y2
1206
ZP1
7D471
2
1206
AC
V+
AC
V-
474/300V
C1
R2
750K
C5
GBU406
1
+
4
3
C20
1206
270P/1KV
B1,2
1
D3
2
RH4*2*3
7,8,9 FCF10A40
T1A
68U/400V
T50-26B
C4
332
Y2
C12
T1
10,11
1
T1B
ZP2
SMAJ64A
C13
C
TR13
L3A
DR6*8
+
C14
47U/63V
8*16
2
COM
13*25
PA
L3B
C22
103
VI-
1
LT C4274
4
O-
M1
3
ZPX
NT C1
F1
C21
+
103
7UH
M1=MS-PSE-014A-4(4274)
C17
103/1KV
LB2
SMAJ64A
C11
1
AC/L
L2
18*26
C3
222
Y2
L5
3.8mH~4.0mH
R25
2512 100R
2
EE25 30mH
L1
L4
103/1KV
AC/N
470U/63V
PQ2625
AC 90 ~ 264V
C
601A
AC/L
T50-26B
T2A/250V
B
C19
332
Y
222/250V
10D005
B
Y1
S3
FG
A
A
1
2
3
4
5
When lightning:
1. Route S1 will be absorbed by ZP1, will not affect the circuit.
2. Route S2 via FG to second, will pass by PSE, due to PSE reset
3. Route S3 via ZPX, will not due to PSE reset.
Hi-POT
The primary to FG =DC3000V, the second to FG=DC1000V
6
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement