C-Bus Control and Management
3
Commercial Dimming Solutions
C-Bus Network Design Considerations
4
Commercial Dimmers
38 – 41
C-Bus Dynamic Labelling Technology
6
System Units and Accessories
42 – 45
Reflection Key Input Unit
8
Pascal Automation Controller
42
Saturn Key Input Units
10
Telephone Interface Unit
42
Modena 800 Series Key Input Units
12
DALI Gateway
43
C2000 / Slimline Key Input Units
14
Power Supply
43
C-Bus Colour Touch Screen
16
PC Interface
43
C-Bus MKII Black & White Touch Screen
18
Ethernet Network Interface
44
20 – 21
Network Bridge
44
®
Input Units
36
General Input Units
20
C-Bus BACnet Gateway
44
Bus Coupler
20
Wireless Gateway
45
21
Installer Tools
45
Multi-Room Audio System - Overview
46
Auxiliary Input Unit
Sensors/Thermostats
Outdoor
Indoor
21 – 23
21
Multi-Room Audio System
48 – 53
21 – 22
Matrix Switcher
48
Light Level Sensor
22
Amplifiers
49
Temperature Sensor
22
Speakers
50 – 51
Room Thermostats
23
Accessories
52 – 53
IR Wall Units
24
C-Bus Software
54 – 56
Infrared Output Units
25
C-Bus OPC Server
56
Remote Controls
26
Citect Facilities
57
Output Units – Wall Mounted
28
C-Bus Wireless Control and Management System
58
Output Units – Din Rail Mounted
29 – 35
Typical Schematics
66 – 67
Technical Drawings
68 – 70
Universal Dimmer
29
Leading Edge Dimmer
30
DSI Gateway
31
0-10V Analogue Unit
31
Relay Units
Shutter Relay
34
Standard Relay Units
35
2
32 – 34
For more information on any products listed in this guide, please contact
Schneider Electric Customer Care on 0508 254 7725 or visit www.clipsal.co.nz
C-Bus Control and Management
Overview
> Introduction
C-Bus was first developed back in 1994, initially designed and
manufactured for commercial lighting control applications, it
was soon migrated to the residential market due to increasing
world-wide demand.
The C-Bus system is a microprocessor based wiring system
specifically designed to control lighting and other electrical
services.
C-Bus information is held within individual C-Bus units rather
than one central point. This ensures optimum communications
speed and reliability.
While a computer is unnecessary for normal C-Bus operation,
C-Bus PC based control and management software
is available and provides additional flexibility to clients
requiring this type of control.
Whether it’s ON/OFF control of a lighting circuit, an analogue or
digital form of control such as dimming electronic fluorescent
ballasts; C-Bus can control and automate virtually any type of
electrical load.
C-Bus is suitable for a wide range of applications, for example:
>>
Fluorescent lighting control for energy cost saving in
high rise buildings.
To ensure fast and reliable operation, each device has
its own in-built microprocessor, which can be individually
programmed via ‘point and click’ PC based software.
>>
>>
>>
High-bay control in warehouses for energy cost saving.
>>
Architectural lighting control for hotel foyers, ballrooms,
art galleries and museums.
Commercial Lighting Control
Mood lighting in restaurants and retail outlets.
Flexible and integrated control of lighting and
audio-visual equipment in boardrooms.
Standalone Room Lighting Control
>>
Integrated automation via touch screen user interfaces
for conference rooms and home theatres.
>>
Multiple scene/mood setting.
Residential Automation
>>
Home
entertainment – Integrated audio-visual, lighting
control, and other electrical services
>>
Security
– Integrated security, lighting and other
electrical services.
>>
>>
Comfort
– Dimming, scene setting.
Convenience – Multiple point control or central point
control from touch screens, automated time based
control, automated ‘Goodbye’ and ‘Welcome Home’
scenes.
3
C-Bus Network Design
Considerations
>>
Up to 1000m of C-Bus Cat 5 UTP cable may be
connected to a single C-Bus network
>>
C-Bus power supply units may be connected to different
phases
>>
Up to 100 C-Bus units may be connected to a single
C-Bus network
>>
Individual relay channels may be connected to different
phases
>>
Where more than 1 km and/or 100 standard C-Bus units
are required, two or more networks can be created and
linked with C-Bus Network Bridge and/or C-Bus Ethernet
Interface Units
>>
On L5508D1A units the mains supply to the units power
supply and the mains supply to the output channels
must be on the same phase
>>
Maximum number of networks in one installation is
255 (this limitation does not apply if a C-Bus Ethernet
Interface is utilised, the system size is then limited to IP
Addressing only)
>>
The isolation between the mains supply circuitry and
the 36V DC C-Bus circuitry is greater than 3.5kV. This is
achieved using double wound transformers and optoisolators. This means the C-Bus wiring, connections and
circuitry can be considered extra low voltage
>>
Maximum number of networks connected in series to the
local network via Network Bridges is seven (i.e. using six
network bridges)
>>
>>
Each standard C-Bus unit requires 18mA @ 36V DC
to operate correctly. Some C-Bus units, e.g. 5500PC
require 36mA. Some C-Bus units, e.g. L5108D1A are
self-powering and do not take current from the 36V DC
C-Bus network
C-Bus Cat 5 UTP cable has mains rated sheathing which
means the C-Bus cable can be taken inside electrical
Distribution Boards, provided segregation requirements
of local wiring standards are met.
>>
More than one C-Bus power supply can be connected to
a C-Bus network to provide sufficient power to the C-Bus
units, the C-Bus power supplies will share the load
evenly. Maximum total power supply allowed is 2,000mA
(2A)
>>
Any combination of power supply units is allowed as
long as the total power available is 2,000mA or less
>>
Each C-Bus network requires only one network burden.
This network burden is software selectable on C-Bus
output units
>>
Each C-Bus network requires at least one system clock
generating unit (for data synchronisation)
4
NEXT
RELAX
PLAY CD
DINING
LOUNGE
I
Typical C-Bus Application –
Board Room or Lecture Theatre
Typical C-Bus wiring schematics are shown on pages 66-70
5
C-Bus
Dynamic Labelling Technology
5080DL Series
Dynamic Labelling Technology (DLT) has been incorporated
in C-Bus Saturn units allowing C-Bus installers to
electronically label switches according to the requirements
of the user and easily change this labelling via software,
as required.
Features
>>
>>
Impact resistant glass fascia.
Dynamic Labelling Technology switches incorporate
editable LCD text or bitmap labels, plus function indicators
such as bar-graphs. The units have eight programmable
buttons for C-Bus Group/Scene control over two pages, with
a Scroll button to toggle between these pages. The 64 x 128
pixel LCD screen incorporates a backlight. Text, sliders and
bitmaps can be defined in the C-Bus Toolkit software and
downloaded to the unit via a C-Bus network.
>>
>>
LCD labelling for each switch.
>>
>>
Page/scroll button.
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
64 x 128 pixel screen.
6
Editable LCD labels with Dynamic Graphic Displays,
which can be optionally enabled/disabled.
Eight switches for C-Bus group/scene over two pages
(four buttons per page).
Each can be programmed as on/off, dimming, time
or a scene control.
More than 20 languages supported.
Dimmable White LED backlighting for the LCD.
Dimmable Blue LED on each button.
Ignore first key press option.
Fallback to page 1 option.
Real-time Clock Display.
Programmed via C-Bus Toolkit software.
Nightlight on all keys or just 5th key.
LCD feedback under Learn Mode.
Learn Mode enabled.
Product Specifications
Catalogue Number
5080DL Series
C-Bus supply voltage
15 – 36V DC, 22mA for normal operation.
Does not provide current to the C-Bus network
AC input impedance
50kΩ @ 1kHz
Electrical isolation
3.75kV RMS from C-Bus to mains
(provided externally to the unit)
Max. no. of units on network
50 units
Control functions
Load switching, dimming, timing, scene control
Status indicators
Blue, one indicator per button (dimmable)
Backlight
White, user configurable (dimmable)
Warm-up time
5 seconds
C-Bus connection
One terminal block to accommodate 0.2 to 1.5mm (24 to 16 AWG)
Operating temperature range
0 – 45°C
Operating humidity range
10 – 95% R.H.
Product Range
Catalogue Number
Description
5085DL, GF
Saturn glass fascia C-Bus switch,
incorporating Dynamic Labelling Technology,
5 buttons, white, Learn Enabled.
5085dl-680
Saturn glass fascia C-Bus switch,
incorporating Dynamic Labelling Technology,
5 buttons, white, Learn Enabled.
5085dl-J80
New
2009
Saturn stainless steel fascia C-Bus switch,
incorporating Dynamic Labelling Technology,
5 buttons, Learn Enabled.
7
Reflection
Key Input Unit
R5060NL Series
The C-Bus Reflection Range of architectural, flat metal
style Input Units are available in a brushed stainless steel
finish. The units feature a magnetic mounting mechanism,
which ensures that the installed product does not have any
visible mounting screws.
Each switch on the plate has an associated blue LED
indicator providing feedback status. The Reflection Range
supports a wide range of functions, such as Toggle, On, Off,
Timer, Dimmer, Remote Scene Selection, etc.
Note that a custom Wall Box is required to mount this switch
(catalogue number R5060WB, sold separately). Standard
wall brackets and boxes cannot be used. The R5060WB Wall
Box is fully adjustable allowing the Reflection Key Input Units
to mount flush with any flat wall surface in a wide variety of
building styles.
Features
The Reflection Range is not weatherproof, and is therefore
not suitable for external/outdoor use.
>>
>>
>>
Architectural design.
Stylish screwless stainless steel fascia.
Magnetic fascia plate allows quick and easy assembly
and removal.
>>
>>
Available in 1, 2, 3, 4, 6 or 8 gang configuration.
>>
Functions include: on, off, toggle, dimmer, ramp up,
ramp down and scene control.
>>
Removable ‘metal look’ buttons for engraving or
pad printing.
>>
>>
Grid mount configuration.
>>
Mounted to a custom Reflection Range wall box
(R5060WB, ordered separately), which incorporates
internal height adjusters allowing perfect flush mounting.
>>
Up to 8 keys can be set as scene controllers via the
installation software.
>>
Learn Mode enabled.
Each key has a blue LED status indicator providing
feedback status from the network.
Incorporates internal height adjusters allowing perfect
flush mounting.
Reflection Wall Box
8
Product Specifications
Catalogue Number
R5060NL Series
C-Bus supply voltage
15 to 36V DC
Current drawn
18mA
AC input impedance
100kΩ @ 1kHz
Max. no. of units on network
100 units
C-Bus unit type
KEYA1
KEYAV2
KEYA3
KEYAV4
KEYA6
KEYA8
Control functions
Load switching, dimming, timing, remote scene triggering
Status indicators
Blue, one indicator per key
Nightlight option
Allows blue LED backlight illumination
Warm-up time
5 seconds
Storage temperature range
-10 to 60°C
Operating temperature range
0 to 45°C
Operating humidity range
-10 to 95% R.H.
C-Bus input terminals
0.2 to 1.5mm2 (24-16AWG)
Dimensions (L x W x H)
115 x 70 x 31mm key unit
R5061NL
R5062VNL
R5063NL
R5064VNL
R5066NL
R5068NL
103 x 60 x 40mm wall box
Product Range
Catalogue
Number
Description
R5061NL
1 gang key input unit, stainless steel
R5062VNL
2 gang key input unit, stainless steel
R5063NL
3 gang key input unit, stainless steel
R5064VNL
4 gang key input unit, stainless steel
R5066NL
6 gang key input unit, stainless steel
R5068NL
8 gang key input unit, stainless steel
R5060WB
Wall box to suit reflection range key
input unit
9
Saturn
Key Input Unit
5080NL Series
The C-Bus Saturn series of Key Input Units enables control
of electrical loads such as lighting and air conditioning via
the C-Bus Network. Saturn is an innovative user interface that
incorporates style and functionality.
Suitable for the most exclusive interiors, Saturn features an
impact resistant transparent glass fascia with a white backing.
The round silver push buttons incorporate a configurable
blue or orange LED, giving a stunning luminous glow and
providing status feedback from the C-Bus Network.
Available in 2, 4 or 6 gang switch configuration, each switch
can be programmed with on, off, toggle, dimmer, timer, scene
control and custom functions.
10
Features
Incorporating standard mounting centres Saturn can be easily
mounted using standard mounting accessories including wall
boxes and plaster brackets.
>>
Enables control of electrical loads such as lighting via
the C-Bus Network.
>>
Impact resistant transparent glass fascia with a white
backing.
>>
>>
Available in 2, 4 or 6 gang switch configuration.
>>
Round silver tactile switch buttons incorporate a
configurable blue or orange LED indicator.
>>
LED switch indicators provide illumination and status
feedback and are configurable as follows:
-
-
-
-
-
-
-
>>
Nightlight function with ‘ignore first key press’ option
when nightlight is on.
>>
Fall back level option to dim indicators at a set time after
the last key press.
>>
Programmed via Learn Mode or the C-Bus Installation
Software.
>>
Communication with other C-Bus devices and the supply
voltage is obtained via a single C-Bus twisted pair cable.
>>
An inbuilt non-volatile memory retains programmed
information of the unit in the event of a power failure.
>>
Mounted via standard mounting accessories, e.g. wall
boxes and plaster brackets (ordered separately).
Each switch can be programmed with on, off, toggle,
dimmer, timer, scene control and custom functions.
Blue ON, Orange OFF
Orange ON, Blue OFF
Orange ON, nothing OFF
Blue ON, nothing OFF
Orange ON all the time
Blue ON all the time
Orange and Blue always OFF
Product Specifications
Catalogue Number
5080NL Series
C-Bus supply voltage
15–36V DC @ 22mA required for normal operation.
Does not provide current to the C-Bus Network.
AC input impedance
50kΩ @ 1kHz
Electrical isolation
3.75kV RMS from C-Bus to mains (provided
externally to 5080 Series Unit)
Max. no. of units on network
50 units
Control functions
Load switching, dimming, timers, scene control
Status indicators
User configurable Orange and Blue
Warm-up time
5 seconds
C-Bus connection
One terminal block to accommodate 0.2 –1.5mm2
(24-16 AWG)
Operating temperature range
0 – 45°C
Operating humidity range
10 – 95% R.H.
Product Range
Catalogue Number
Description
5082NL,GF
2 key input unit, white glass fascia
5084NL,GF
4 key input unit, white glass fascia
5086NL, GF
6 key input unit, white glass fascia
5082NL-680
2 key input unit, black glass fascia
5084NL-680
4 key input unit, black glass fascia
5086NL-680
6 key input unit, black glass fascia
5082NL-J80
2009
5084NL-J80
2009
5086NL-J80
2009
New
New
New
2 key input unit, stainless steel fascia
4 key input unit, stainless steel fascia
6 key input unit, stainless steel fascia
5080LC-8
Pre-labelled button caps
5080F,WE
Mounting frame, white
11
Modena
New
2009
Key Input Unit
800 Series
This new European inspired range of C-Bus enabled
switches has all the functionality of the C-Bus Saturn
range and will match the rest of the PDL 800 Modena
range of wall plates within the home.
Each button has a dual colour LED for button status
feedback. All typical button functions are included for
lighting type applications involving scene control. C-Bus
Modena wall switches will seamlessly integrate with all
current and legacy C-Bus hardware including C-Bus
Touch Screens for complete control of the home.
C-Bus Modena is available in white or black with 2, 4, or
6 button options. Nine interchangeable coloured picture
frame surrounds provide 36 possible style combinations.
12
Features
>>
>>
>>
European inspired design.
>>
Control of typical electrical loads such as lighting,
heating, irrigation control via the C-Bus network.
>>
>>
>>
>>
>>
>>
Available in 2, 4 or 6 button configurations.
>>
Mounted via standard mounting accessories,
e.g. wall boxes and plaster brackets.
>>
Learn Mode enabled.
Aesthetically matches the PDL Modena 800 Series®.
Each button can be programmed for on, off, toggle,
dimmer, timer scene control and custom button
functions.
Dual status LED – Blue/Orange.
Variable indicator brightness.
Fall back dim indicator options.
Nightlight and timer functions.
Built-in non-volatile memory retains programmed
information in the event of power failure.
Product Specifications
Parameter
Description
C-Bus supply voltage
15 to 36V DC, 22mA for normal operation.
Does not provide current to the C-Bus network
C-Bus AC input impedance
50kΩ @ 1kHz
Electrical isolation
3.75kV RMS from C-Bus to mains
(provided externally to LHC88x Series unit)
Max. no. of units on network
50
Control functions
Load switching, dimming, timers, scene control
Status indicators
User configurable Orange and Blue
Warm-up time
5 seconds
C-Bus connection
One terminal block to accommodate
0.2 to 1.3mm2 (24 to 16 AWG)
Operating temperature range
0 to 45°C
Operating humidity range
10 to 90% RH
Product Range
Catalogue
Number
LHC882,WH
Description
New
2009
2 gang key input unit, Modena style, white
LHC884,WH
2009
LHC886,WH
2009
LHC882,BK
2009
New
2 gang key input unit, Modena style, black
2009
New
4 gang key input unit, Modena style, black
New
6 gang key input unit, Modena style, black
LHC884,BK
LHC886,BK
New
New
2009
4 gang key input unit, Modena style, white
6 gang key input unit, Modena style, white
13
Standard C-Bus
Key Input Units
Slimline™ SC2000 Series
Classic C2000 Series
SC5031NL
C5034NL
C5031NL
SC5031NL
Wall switch 1 gang, orange LED
C5031NL
Wall switch, 1 gang
SC5032NL
Wall switch 2 gang, orange LED
C5032NL
Wall switch, 2 gang
SC5034NL
Wall switch 4 gang, orange LED
C5034NL
Wall switch, 4 gang
SC5031BNL
Wall switch 1 gang, blue LED
SC5032BNL
Wall switch 2 gang, blue LED
SC5034BNL
Wall switch 4 gang, blue LED
Features
>>
May be programmed as dimmers, timers and on/off
toggle switches.
>>
>>
1, 2 or 4 buttons per wall switch.
>>
Available in white or black, with the standard Slimline
SC2000 range of cover plate options.
>>
>>
Units draw 18mA from a C-Bus network.
14
Each button features a programmable LED
status indicator.
C-Bus Learn Enabled.
Features
>>
May be programmed as dimmers, timers and on/off
toggle switches.
>>
>>
>>
1, 2 or 4 buttons per wall switch.
>>
>>
Units draw 18mA from a C-Bus network.
Each button features a programmable status indicator.
Available in white or black, with the standard C2000
Classic range of cover plate options.
C-Bus Learn Enabled.
Desire the look,
have it all
Offer your customers
a seamless electrical
solution for their
home or business.
Perfectly match
their chosen C-Bus
automation range
with the equivalent
250V electrical
accessories.
Complementary ranges to
the C-Bus automation
offer include:
>>
>>
>>
>>
Saturn 250V
Modena 800 Series
Slimline SC2000 Series
C2000 Classic Series
For more information contact Schneider Electric customer care 0508 254 7725
15
C-Bus
Colour Touch Screen
5080CTC Series
C-Bus Colour Touch Screen is a wall mounted, touch sensitive
LCD screen that can display pages of graphical items such
as buttons sliders and images. These graphical items perform
C-Bus related functions when pressed.
The unit also includes a real-time clock for automatic
scheduling of events based on the time of day, week, month
or year. The touch screen allows control via an infrared handheld remote control unit.
C-Touch Colour can be completely customised to suit
user requirements via the included Windows™ compatible
configuration software. The software also includes a Logic
Engine module that allows the installer to program logic
based control into the touch screen configuration.
Available in Stainless Steel and Saturn glass style surrounds,
the Colour Touch Screen is not only aesthetically appealing,
but an extremely functional addition to the comprehensive
range of C-Bus products.
16
Features
General
>>
Connects directly to a C-Bus network
(no external PC interface required).
>>
Control and monitor devices connected to C-Bus,
Ethernet and RS-232 (Custom Ethernet and RS-232
support via the included logic programming language).
>>
On-board audio supports external speakers
and microphone.
>>
>>
>>
Unit programmable via Ethernet.
Real-time clock (astronomical).
256MB compact flash factory programmed with Touch
Screen firmware.
Software
>> GUI based drag and drop configuration software,
plus Freeform logic programming language.
>>
Software interface design supports 101 levels of
alpha blending.
>>
Animated buttons with more than 256 animation
frames supported.
>>
Fully customisable graphics including bar graphs,
sliders, percentage indicators, images, gauges and
clocks with any border and background style.
>>
>>
>>
>>
>>
>>
>>
>>
Supports web page embedding.
Supports project theme templates.
Audio WAV file support.
Scene control.
Event scheduling support.
Astronomical clock support.
Irrigation control.
Password access control.
Product Specifications
Catalogue Number
5080CTC
Screen type
LCD active matrix
Screen size
6.4 inch (diagonal)
Screen resolution
VGA, 640 x 480 pixels
Pixel pitch
0.204mmx 0.202mm (H x V)
Screen viewing area
130.6mm x 97.0mm (H x V)
Touch overlay type
Resistive membrane
Viewing angles
Horizontal: typical. 70° left and right
Vertical: typical. 40° up, 70° down
Luminance
300cd/m2
Backlight
Cold cathode with light sensor for automatic backlight level control
Memory
256MB compact flash factory programmed with panel firmware
Front panel
Ethernet 10/100 Port: RJ-45 port (under fascia)
Speaker (under fascia)
Infrared receiver
Rear connectors
C-Bus RJ-45 connectors, x 2
Ethernet 10/100 Port: RJ-45 port for communication
Composite video output via RCA socket (75ohm)
RS-232 via DB 9 connector
2 x USB (type A connectors) for future software support
Remote IR input (hardwired via 3.5mm mini-jack)
External speaker/headphone connector: 3.5mm mini-jack
Enclosure
Moulded Faradex
Fascia
Saturn style: Glass
Power
<5A @ 5V DC (Power pack included)
Dimensions (W.H.D)
248mm x 175mm x 60mm
Product Range
Catalogue Number
Description
5080CTC2, GF
C-Bus Colour Touch Screen, 6.4 inch screen, white glass fascia
5080CTC2-6
C-Bus Colour Touch Screen, 6.4 inch screen, black glass fascia
B55000CTC2
C-Bus Colour Touch Screen, 6.4 inch screen, stainless steel fascia
5000ctcps
C-Bus Colour Touch Screen, Power Supply Version 1
5000ctcps/2
C-Bus Colour Touch Screen, Power Supply Version 2
17
C-Bus
MKII Black & White Touch Screen
5080CTC2 Series
The massively enhanced C-Bus MKII Black & White Touch Screen,
builds on the success of the original Monochrome touch screen.
User Benefits
>>
>>
>>
>>
>>
>>
To provide the user with an improved interface, the following
have been included:
Bigger screen.
Enhanced contrast.
Superior backlighting.
Available with or without C-Bus Logic Engine.
Models with RS-232 integration.
USB programming port accessible from the front
of the unit.
>>
The unit includes a new, larger LCD screen. This has
50% more screen area than the Monochrome model.
>>
Improved, adjustable LCD screen backlighting with
ambient light compensation.
>>
The super bright LCD uses white on black technology
to enhance clarity.
>>
vailable in the white glass, black glass, stainless
A
steel or white plastic fascia styles.
Installer Benefits
To ensure the unit is quicker, easier and more flexible to install
and commission, the following features have been included
in the MKII unit:
18
>>
Program via a standard USB port on the front of
the unit.
>>
>>
The USB port can be used as a PC interface.
>>
Compatible with Version 4 of the C-Bus Windows™
based programming software.
>>
Available with or without built-in Logic Engine features.
A separate RS-232 port is included on the rear of the unit
for third-party device integration*.
* RS-232 available on Logic engine modules only.
Product Specifications
Parameter
Description
Screen size
119mm (diagonal)
Resolution
QVGA (320 pixels x 240 pixels)
Control functions
• Load switching and dimming
• Scenes
• Logic (Versions with Logic Engine only) • Schedules
Power supply
Powered directly from C-Bus15-36V DC @ 65mA required for normal operation.
Does not provide current to the C-Bus Network.
Maximum number of
controlled loads
255 Group Addresses on each of 10 C-Bus Applications
Maximum number of C-Touch
units on a single
C-Bus network
10
C-Bus connection
Loop-in/Loop-out removable terminal block for C-Bus
Third party interface
RS-232 port (supported by the version with C-Bus Logic Engine only)
Programming port
USB Type B (under front fascia)
Overall dimensions
Plastic Fascia Version
SaturnTM Fascia Version
Stainless Steel Fascia Version
Operating temperature range
10 to 45°C
Operating humidity range
10 to 95% R.H.
Fascia styles
SaturnTM, Stainless steel, Flat plastic
Accessories
RS-232 lead (only required for integrating to third-party devices) Part number 5000CT2RS232
4.7 inches (diagonal)
W = 193mm
W = 195mm
W = 193mm
100mm x 75mm (W x H)
H = 134mm
H = 136mm
H = 134mm
D = 41mm
D = 47mm
D = 45mm
Wall box Part number 5000CT2WB (external dimensions 179.5x122.5x55mm)
Dimensions (WxHxD)
248mm x 175mm x 60mm
Product Range
Catalogue Number
Description
5080CTL2, GF
C-Bus Monochrome Touch Screen, 4.7 inch screen, white glass fascia with logic engine
5080CTL2-6
C-Bus Monochrome Touch Screen, 4.7 inch screen, black glass fascia with logic engine
BS5000CTL2
C-Bus Monochrome Touch Screen, 4.7 inch screen, stainless steel glass fascia with logic engine
5080CT2,GF
C-Bus Monochrome Touch Screen, 4.7 inch screen, white glass fascia no logic engine
500CT2-6
C-Bus Monochrome Touch Screen, 4.7 inch screen, white glass fascia no logic engine
BS5000CT2
C-Bus Monochrome Touch Screen, 4.7 inch screen, stainless steel fascia no logic engine
SC5000CT2,WE
C-Bus Monochrome Touch Screen, 4.7 inch screen, white plastic fascia no logic engine
5000CT2WB
Wall box for MK2 Touch Screen
19
Input Units
General Analogue/Digital
Input Unit
Bus Coupler Input Unit
5504GI
General input unit, 4 Channel
5104BCL
Bus coupler input unit, 4 Channel
>>
>>
>>
>>
>>
104BCL used to interface up to 4 standard voltage
5
free mechanical switches, including latching and toggle
switches to C-Bus.
>>
>>
>>
>>
Dimensions 55mm x 49mm x 18mm.
>>
>>
Units draw 18mA from a C-Bus network.
>>
Four channel general input unit, DIN rail mounted.
8M DIN modules wide.
Dimensions 144mm x 85mm x 65mm.
sed to interface a C-Bus system to third-party products
U
such as light level sensors, current sensors, temperature
sensors, CO2 detectors, differential sensors, pressure
sensors, flow rate sensors, moisture probes etc. Ideal
for 4-20mA current loop applications.
Designed to either trigger the state of a C-Bus group
address as a function of input level or broadcast
a message on the C-Bus network, representing
the input level.
>>
>>
Maximum of 10 units on a single C-Bus network.
>>
>>
Requires a 24V DC connection (power pack included).
20
an be used to measure analogue values (0-1V, 0-5V,
C
0-10V, 0-20V, 0-20mA, 4-20mA, 500 Ohm, 1k Ohm,
3k Ohm and 10k Ohm thermistor inputs).
Units draw 18mA from a C-Bus network.
The unit is designed to fit into a standard wall box.
Each unit features a programmable status indicator.
he maximum distance between the unit and an external
T
voltage free switch is limited to 1 metre (use L5504AUX if
longer distance required).
C-Bus Learn Enabled.
DIN Rail Mounted
Auxiliary Input Unit
Passive Infrared
Motion Detectors
L5504AUX
Auxiliary input module, 4 Channel
5750WPL
Occupancy sensor, infrared, IP66, outdoor
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
Four channel auxiliary input module, DIN rail mounted.
4M DIN modules wide.
Dimensions 72mm x 85mm x 65mm.
Permits voltage free switches to be connected to C-Bus.
Each unit features a programmable status indicator.
The unit may be programmed in the same way as a wall
switch, to achieve the same functions such as timer,
dimmer or toggle switches.
Units draw 18mA from a C-Bus network.
PIR motion sensor suitable for outdoor use.
The unit has a field of view of 110 degrees and
a detection range which extends 18 metres.
>>
>>
The unit features a light threshold adjustment.
>>
>>
>>
Features a sunset switch program.
The time delay is programmable in the range 1 second
to 18 hours.
Units draw 18mA from a C-Bus network.
C-Bus Learn Enabled.
C-Bus Learn Enabled.
5751L
Occupancy sensor, infrared,
indoor, corner mount
>>
>>
PIR motion sensor suitable for indoor use.
The unit has a coverage range of 6m x 6m and a field of
view of 90 degrees.
>>
>>
The unit features a light threshold adjustment.
>>
>>
>>
Features a Sunset Switch program.
The time delay is programmable in the range 1 second
to 18 hours.
Units draw 18mA from a C-Bus network.
C-Bus Learn Enabled.
21
Input Units
Passive Infrared
Motion Detectors cont’d
Light Level
Sensor
5753L
Occupancy sensor, infrared,
indoor, flush mount, 360 degree
5031PE
Light level sensor, 40 – 1600lux.
>>
360 degree, flush, ceiling
mount PIR motion sensor.
>>
>>
Suitable for indoor use.
>>
>>
The unit features a light threshold adjustment.
>>
>>
>>
Features a Sunset Switch program.
The unit has a coverage range of 6m x 6m and a field of
view of 90 degrees.
The time delay is programmable in the range 1 second
to 18 hours.
Units draw 18mA from a C-Bus network.
C-Bus Learn Enabled.
5753PEIRL
Multisensor, combined occupancy
sensor, light level sensor and
IR receiver
5031PE
>>
Used to measure and regulate lighting in the range of
40 – 1600lux.
>>
Programmable target light level as well as the margin
on installation.
>>
>>
Each unit features a programmable status indicator.
>>
Units draw 18mA from a C-Bus network.
Can be used to achieve bank switching
or continuous dimming.
Temperature Sensor
5031RDTSL
Temperature sensor,
with temperature broadcast
0 – 50 degrees Celsius
New
2009
>>
Used to measure or regulate either heating
or cooling in the range 0 - 50 degrees Celsius.
5031rdtsl
>>
Flush mount design with
360 degree detection pattern.
>>
>>
Capable of controlling up to 8 C-Bus Scenes
or 8 C-Bus Group Addresses.
Programmable temperature target and margin
on installation.
>>
>>
Supports the ‘Corridor Linking’ feature for commercial
building applications.
Programmable setback temperature economy mode for
when room is not in use.
Temperature broadcast facility.
>>
Three LEDs indicate a range of actions from movement,
to the receiving of IR commands and the device’s status.
>>
>>
>>
Light and PIR sensitivity are set via adjustment screws
located on the sensor unit.
>>
>>
Can be used as a measurement device for touch screens.
>>
>>
Dual element detectors minimise false triggering.
>>
An LED status indicator on the unit is used to report the
current state of the load controlling device.
>>
>>
Unit draws 18mA from a C-Bus network.
22
Refer to 5753PEIRL Installation Instruction for location
and mounting details.
C-Bus Learn Enabled.
Can be used as a remote sensor for the C-Bus 4-zone
room thermostat units.
Units draw 18mA from a C-Bus network.
Single Zone
Thermostat
5070THBR
C-Bus thermostat, programmable,
single zone with 5 relays (relays
for HVAC plant control only, not
accessible via C-Bus)
4 Zone Thermostat with
Programmable Time Scheduling
New
2009
5070THPR
C-Bus thermostat, programmable, 4
zone, with 5 relays (relays for HVAC
plant control only, not accessible via
C-Bus)
5070THB
C-Bus thermostat,
programmable, single zone,
no on board HVAC plant
control relays
5070THP
C-Bus thermostat,
programmable, 4 zone,
no on board HVAC plant
control relays
>>
>>
>>
>>
>>
4 zone (plus the common zone) programmable
C-Bus thermostat.
Wall mounted.
Support for control of HVAC units via C-Bus or the
internal HVAC relays (‘RWG’ control).
>>
>>
>>
>>
Manually adjustable temperature set point and mode
of operation (heating, cooling or ventilation).
>>
>>
The unit includes fan speed control and a ‘Setback’
or ‘Economy’ Mode.
Manually adjustable temperature set point, mode
of operation (heating, cooling or ventilation) and
time schedules.
>>
Easy to use operator interface includes an integral LCD
to display the current temperature and mode
of operation.
>>
On board 7 day HVAC time scheduling (user
programmable), manual fan speed control,
and setback mode.
>>
>>
Draws 40mA from a C-Bus network.
>>
Easy to use interface, comprising an LCD, manual
control buttons and a rotating dial with an integral
press switch.
>>
>>
Draws 40mA from a C-Bus network.
Single zone C-Bus thermostat.
Wall mounted.
Dimensions 92mm x 127mm x 24mm.
vailable in white and black glass fascia’ or a brushed
A
stainless steel finish.
New
2009
Dimensions 105mm x 149mm x 24mm.
Support for control of HVAC units via C-Bus or directly
using on board HVAC relays (RWG control).
vailable in white and black glass fascia’ or a brushed
A
stainless steel finish.
23
IR Wall Units
Infrared Receivers
>>
Wall mounted IR receiver incorporating 4 stations
of IR receivers.
>>
>>
Available with or without C-Bus buttons.
>>
>>
Units draw 18mA from a C-Bus network.
May be programmed to achieve functions such
as a dimmer, timer or toggle switch.
Classic C2000 Series
C5031NIRL
4 Channel infrared receiver
C-Bus Learn Enabled.
2000 Series
C5034NIRL
4 Channel infrared receiver
with 4 buttons
5031NIRL
4 Channel infrared receiver
5031NIRL
Slimline™ SC2000 Series
5034NIRL
4 Channel infrared receiver
with 4 keys
5034NIRL
SC5031NIRL
4 Channel infrared receiver
SC5034NIRL
4 Channel infrared receiver
with 4 buttons
24
Infrared Output Units
Infrared Output Units
>>
>>
Transmits IR codes to third-party devices.
Capable of broadcasting IR messages through two
IR output channels (consist of 3.5mm mini audio
mono sockets).
>>
Single or dual head emitter leads (ordered separately)
should be connected to the output jacks.
>>
Programmed via the High Speed Programming Cable
(part number 5100HSCU, ordered separately).
>>
The installer has the facility to modify the stored codes
using Windows™ based application software.
>>
>>
Stores a library of commonly used IR codes.
>>
The standard colours are White Electric, Soft Grey,
Desert Sand, Cream, Brown and Black.
>>
Units draw 32mA from the C-Bus network.
Infrared Output Units
Accessories
5100HSCU
High speed USB
programming cable
for C-Bus 2 channel
infrared transmitter unit
The Infrared Controller is based on 2000 Series, SC2000
Series and C2000 Series 4-gang wall switches.
5034NIRT
2 channel infrared transmitter
unit, 2000 Series wall plate
5100RP
Infrared code learning unit,
complete with Windows™
based software. Required for
learning third-party infrared
codes not included in the code
library shipped with the infrared
transmitter unit software
C5034NIRT
2 channel infrared transmitter unit,
Classic C2000 Series wall plate
SC5034NIRT
2 channel infrared transmitter
unit, Slimline SC2000 Series
wall plate
25
Remote Control Units
Universal Infrared Remote
Control Unit
>>
Universal, hand-held, infrared remote control unit for
control of electronic devices equipped with an infrared
(IR) remote.
>>
Control of up to 16 devices including C-Bus, DVDs, TVs,
satellite receivers, VCRs and CDs.
>>
>>
>>
Large touch screen display.
Blue LED backlighting.
LED indicators provide information and feedback on:
-Status of the beep feature
(audible button press confirmation)
-‘Battery low’ warning
-Confirmation of a successfully transmitted
infrared code
- Error warning
- Touch screen page number.
>>
User programmable buttons for each device include
7 rubber buttons and 48 touch screen buttons.
>>
>>
>>
>>
>>
Quick Control buttons.
>>
Easy to configure with new IR codes using the
‘learning eye’.
>>
>>
Macro function (up to 60 commands per macro).
26
Sleep button.
Page/date button.
Pre-programmed manufacturer codes for many models.
Incorporates embedded C-Bus IR codes for the C-Bus
5038TX and 5035TX IR remote controls.
Learning IR codes from existing remote controls.
5030URC
Universal Infrared Remote
Control Unit, with LCD
touch screen
C-Bus Hand-held
Infrared Transmitters
>>
Designed for use with C-Bus Neo Wall Switches, C-Bus
Multi Sensor and the 503xNIRL series wall switches.
>>
>>
>>
4 and 8 button version available.
>>
The bank selection is changed by removing the
back cover.
Range of up to 15 metres (line of sight).
Features IR Bank selection switch with each group of
four buttons assigned to either bank A/B or bank C/D.
5084TX
4 button C-Bus Infrared
Remote Control with holder
5088TX
8 button C-Bus Infrared
Remote Control with holder
5080TXC
C-Bus Remote
Control Holder (spare)
27
Output Units – Wall Mount
Professional Series
Dimmers
>>
Leading edge dimmers suitable for incandescent and
low voltage lighting.
>>
>>
Dimensions 240mm x 220mm x 75mm.
>>
Incorporate a software selectable network burden and
C-Bus system clock.
>>
>>
>>
Dimmers incorporate a 60mA power supply.
Feature an emergency lighting output in case of loss of
mains power to the unit.
L5104D5
4 Channel Dimmer 250V AC,
5A per channel, 20A total, 60mA
inbuilt C-Bus power supply
Up to 30 units may be connected to any C-Bus network
C-Bus Learn Enabled.
L5102D10
2 Channel Dimmer 250V AC,
10A per channel, 20A total,
60mA inbuilt C-Bus power supply
L5101D20
1 Channel Dimmer 250V AC,
20A per channel, 20A total,
60mA inbuilt C-Bus power supply
28
Output Units – Din Rail Mount
Dimmer Units
– Universal Phase Control
L5504D2U
4 Channel C-Bus Universal Dimmer 250V AC, 2.5A per
channel, inbuilt 200mA C-Bus power supply
L5504D2UP
4 Channel C-Bus Universal Dimmer 250V AC,
2.5A per channel, no inbuilt C-Bus power supply
>>
>>
>>
>>
>>
4 Channel universal dimmer, DIN rail mounted.
>>
>>
>>
>>
>>
4 Channel universal dimmer, DIN rail mounted.
>>
Suitable for low voltage electronic transformers,
incandescent lamps and low voltage lamps with
iron core transformers.
>>
Suitable for low voltage electronic transformers,
incandescent lamps and low voltage lamps with
iron core transformers.
>>
>>
Features automatic load sensing.
>>
>>
Features automatic load sensing.
>>
A maximum of 10 units may be connected to a
C-Bus network.
>>
A maximum of 100 units may be connected to a
C-Bus network.
>>
>>
Features an inbuilt 200mA C-Bus power supply
>>
>>
>>
Does not source current to the network.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 4 Channels of 2.5A rating.
Suitable for use with leading edge or trailing edge
compatible low voltage transformers.
Features a software selectable network burden and
C-Bus system clock.
C-Bus Learn Enabled.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 4 Channels of 2.5A rating.
Suitable for use with leading edge or trailing edge
compatible low voltage transformers.
Features a software selectable network burden and
C-Bus system clock.
Draws 18mA from C-Bus when mains is not connected.
C-Bus Learn Enabled.
29
Dimmer Units
– Leading Edge Phase Control
L5508D1A
8 Channel Dimmer
250V AC, 1A per
channel, inbuilt 200mA
C-Bus power supply
L5504D2A
4 Channel Dimmer
250V AC, 2A per
channel, inbuilt 200mA
C-Bus power supply
>>
>>
>>
>>
8 Channel Dimmer, DIN rail mounted.
>>
>>
>>
>>
4 Channel Dimmer, DIN rail mounted.
>>
Features a software selectable network burden and
C-Bus system clock.
>>
Features a software selectable network burden and
C-Bus system clock.
>>
A maximum of 10 units may be connected to any
C-Bus network.
>>
A maximum of 10 units may be connected to any
C-Bus network.
>>
>>
Features an inbuilt 200mA C-Bus power supply.
>>
>>
Features a 200mA C-Bus power supply.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 8 channels of 1A output, suitable for
incandescent and low voltage lighting.
C-Bus Learn Enabled.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 4 Channels of 2A output, suitable for
incandescent and low voltage lighting.
C-Bus Learn Enabled.
L5508D1AP
8 Channel Dimmer
250V AC, 1A per
channel, no inbuilt
C-Bus power supply
L5504D2AP
4 Channel Dimmer
250V AC, 2A per
channel, no inbuilt
C-Bus power supply
>>
>>
>>
>>
8 Channel Dimmer, DIN rail mounted.
>>
>>
>>
>>
4 Channel Dimmer, DIN rail mounted.
>>
Features a software selectable network burden and
C-Bus system clock.
>>
Features a software selectable network burden
and C-Bus system clock.
>>
A maximum of 100 units may be connected to any
C-Bus network.
>>
A maximum of 100 units may be connected to any
C-Bus network.
>>
>>
Does not source current to the network.
>>
>>
Does not source current to the network.
>>
C-Bus Learn Enabled.
>>
C-Bus Learn Enabled.
30
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 8 channels of 1A output, suitable for
incandescent and low voltage lighting.
Draws 18mA from the C-Bus when mains
is not connected.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Features 4 Channels of 2A output, suitable for
incandescent and low voltage lighting.
Draws 18mA from the C-Bus when mains is
not connected.
C-Bus DSI Gateway
Range
0-10V Analogue
Output Unit
L5508DSI
8 Channel Dimmer for
DSI electronic ballasts
250V AC, inbuilt 200mA
C-Bus power supply
L5504AMP
4 Channel Analogue Output,
0 –10V
>>
>>
>>
>>
>>
>>
>>
>>
>>
8 Channel Dimmer for DSI ballasts, DIN rail mounted.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Provides C-Bus control of electronic DSI digital ballasts.
The module controls up to 100 DSI ballasts per channel.
Up to 10 units may be connected to any
C-Bus network.
Used in conjunction with electronic DSI ballasts.
The dimmer features a 200mA C-Bus power supply.
C-Bus Learn Enabled.
Refer Page 69 for detailed application diagrams on this
product.
>>
Analogue output module,
DIN rail mounted.
>>
>>
>>
>>
4M DIN modules wide.
>>
>>
The unit provides 4 independent output channels.
>>
The polarity of the signal may be selected so that 0V
corresponds to maximum or minimum brightness.
>>
Units draw 18mA from the C-Bus when mains is
not connected.
>>
C-Bus Learn Enabled.
Requires a 240V AC connection.
Dimensions 72mm x 85mm x 65mm.
Can either source or sink current and is used to drive
most types of 0-10V electronic dimmable ballasts.
Powered from C-Bus and requires 18mA at
15 – 36V DC for correct operation.
Refer page 68 for detailed application diagrams on this
product.
L5508DSIP
8 Channel Dimmer for
DSI electronic ballasts
250V AC, no inbuilt
C-Bus power supply
>>
>>
>>
>>
>>
>>
>>
>>
>>
8 Channel Dimmer for DSI ballasts, DIN rail mounted.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Provides C-Bus control of electronic DSI digital ballasts.
The module controls up to 100 DSI ballasts per channel.
Up to 100 units may be connected to any C-Bus network.
Used in conjunction with electronic DSI ballasts.
Units draw 18mA from the C-Bus network when mains is
not connected.
C-Bus Learn Enabled.
Refer Page 69 for detailed application diagrams on this
product.
31
Relay Units
10A Relay Units
L5512RVF/L5512RVFP
12 Channel Relay 250V AC, 10A inductive load per channel.
L5508RVF/L5508RVFP
8 Channel Relay 250V AC, 10A inductive load per channel
>>
>>
>>
>>
>>
12 Channel Relay module, DIN rail mounted.
>>
>>
>>
>>
>>
8 Channel Relay module, DIN rail mounted.
>>
Incorporates a software selectable network burden and
C-Bus system clock.
>>
Incorporates a software selectable network burden and
C-Bus system clock.
>>
A maximum of 10 powered units may be connected to
any C-Bus network.
>>
A maximum of 100 units may be connected to any
C-Bus network.
>>
>>
C-Bus Learn Enabled.
>>
These units draw 18mA from C-Bus network when mains
is not connected.
>>
>>
C-Bus Learn Enabled.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Featuring 12 channels of voltage free relay switching.
Rated at 10A incandescent or 10A fluorescent load
per channel.
Available with or without inbuilt 200mA power supply.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
Featuring 8 channels of voltage free relay switching.
Rated at 10A incandescent or 10A fluorescent load
per channel.
Available with or without inbuilt 200mA power supply.
Catalogue Number
Description
Catalogue Number
Description
L5512RVF
C/W inbuilt 200mA power supply
L5508RVF
C/W inbuilt 200mA power supply
No inbuilt power supply
L5508RVFP
No inbuilt power supply
L5512RVFP
32
20A Relay Units
L5504RVF/L5504RVFP
4 Channel Relay 250V AC, 10A inductive load per channel
L5504RVF20/L5504RVF20P
4 Channel Relay, 250V AC, 20A inductive load per channel
>>
>>
>>
>>
>>
4 Channel Relay module, DIN rail mounted.
>>
>>
>>
>>
>>
4 Channel 20A relay module, DIN rail mounted.
>>
Incorporates a software selectable network burden and
C-Bus system clock.
Relays feature magnetic latching.
>>
A maximum of 10 powered units may be connected to
any C-Bus network.
>>
>>
>>
>>
C-Bus Learn Enabled.
>>
Incorporates a software selectable network burden and
C-Bus system clock.
>>
A maximum of 10 powered units may be connected to
any C-Bus network.
>>
>>
>>
Incorporates an inbuilt 200mA C-Bus power supply.
8M DIN modules wide.
Dimensions 144mm x 85mm x 65mm.
Featuring 4 Channels of voltage free relay switching
Rated at 10A incandescent or 10A fluorescent load
per channel.
Available with or without inbuilt 200mA power supply.
12M DIN modules wide.
Dimensions 215mm x 85mm x 65mm.
4 Channels of voltage free relay switching.
Rated at 20A incandescent, 20A HID or 20A fluorescent
load per channel.
Built-in mechanical level for manual changeover of
relay state.
C-Bus Learn Enabled.
Available with or without inbuilt 200mA power supply.
Catalogue Number
Description
Catalogue Number
Description
L5504RVF
C/W inbuilt 200mA power supply
L5504RVF20
C/W inbuilt 200mA power supply
No inbuilt power supply
L5504RVF20P
No inbuilt power supply
L5504RVFP
33
Relay Units
Changeover Relay Units
Motorised Blinds/Curtains/
Shutter Relay Unit
L5504RVFC/l5504rvfcp
4 Channel Changeover Relay, 250V AC, Learn Enabled
L5501RBCP
C-Bus Motorised
Blinds/Curtains/Shutter Relay,
250V AC, no C-Bus Power Supply
>>
4 Channel changeover relay modules with interlock
features, DIN rail mounted.
>>
>>
>>
>>
8M DIN modules wide.
Single Channel Relay unit for the control of motorised
blinds, curtains or shutters via C-Bus,
DIN rail mounted.
2M DIN modules wide.
>>
The unit can be simply wired to achieve electrical
interlocking, for use where outputs are all
mutually exclusive.
>>
>>
>>
>>
>>
Units draw 18mA from C-Bus when mains is
not connected.
>>
C-Bus Learn Enabled.
Dimensions 144mm x 85mm x 65mm.
Used for control of air conditioning systems (on/off, low,
medium and high) and shutter or blind control
(up/down).
>>
Relays rated at 10A resistive, 5A incandescent/inductive,
1A fluorescent.
>>
Incorporates a software selectable network burden and
C-Bus system clock.
>>
A maximum of 10 powered units may be connected to
any C-Bus network.
>>
These units draw 18mA from C-Bus when mains is
not connected.
>>
>>
C-Bus Learn Enabled.
Available with or without inbuilt 200mA power supply.
Catalogue Number
Description
L5504RVFC
C/W inbuilt 200mA power supply
L5504RVFCP
No inbuilt power supply
34
Dimensions 36 x 85mm x 65mm.
Allows up/down and stop control.
A maximum of 100 units may be connected to
a C-Bus network.
Standard Relay Units
5101R
1 Channel Relay 250V AC 10A inductive load
>>
>>
>>
>>
Single C-Bus relay unit.
5102RVF
2 channel voltage free relay 250V AC,
10A inductive per channel
2 channel C-Bus relay unit.
Suitable for incandescent, inductive and fluorescent
switching up to a maximum load of 10A.
>>
>>
>>
>>
>>
A maximum of 100 units may be connected to any
C-Bus network.
>>
>>
These relays do not draw any current from C-Bus
network when mains power is connected.
A maximum of 100 units may be connected to any
C-Bus network.
>>
These relays do not draw any current from C-Bus
network when mains power is connected.
Dimensions 198mm x 42mm x 39mm.
Featuring 1 channel of 240V AC switching.
Dimensions 198mm x 42mm x 39mm.
Featuring 2 channels of 240V AC switching.
Suitable for incandescent, inductive and fluorescent
switching up to a maximum load of 10A per channel.
35
Commercial Dimming Solutions
Schneider Electric have designed and manufactured a range
of commercial C-Bus dimmers specifically for commercial
dimming applications. After thousands of hours of application
testing and reliability endurance testing, Schneider Electric
now offer two new full ranges of C-Bus enabled Commercial
dimming hardware with a variant to suit any application.
Whether the C-Bus application requires high powered
standard halogen leading or training edge applications or
more complex 0-10volt, DSI or DALI solutions, the C-Bus
Architectural or Professional dimmer range is ideal for any
commercial environment.
With model options rated between 3 amps and 20 amps per
channel* with individually replaceable output cards, these
dimming solutions are at the forefront of commercial dimming
standards and technology. >
Features
>>
>>
High power multi-channel C-Bus dimmer units
>>
>>
Utilises universal dimming technology #
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
Support for onboard lighting scenes #
>>
Manual dimmer bypass switch included on channel
modules
>>
>>
>>
>>
>>
>>
>>
>>
Local override switches
Suitable for the higher end commercial architectural
dimming market
Interchangeable and field replaceable individual
dimming channel modules
Three prioritised emergency auxiliary inputs #
Standby generator auxiliary input #
Emergency lighting output available on each channel
On-board MCB protection
C-Bus or DMX512 operation modes #
Soft start operation
Thermal overload protection
Over current protection
Short circuit protection
Optional output module for DSI, DALI, 0-10VDC or relay
output #
Supplied with easy-mount wall bracket
Generous mains supply terminals and load terminals
Selectable (predefined) dimming curves #
Installer definable dimming curves #
Cross fading scene functions #
Multiple external C-Bus connectors
RCD variants available on request
* Maximum total unit ratings apply.
> All C-Bus Professional and Architectural dimmers are built, tested and comply with Australian/NZ Standard for lightdimmers AS/NZS CISPR 15:2002
# Features are only available on the Architectural range of dimmers.
36
The
Art of dimming
Make every ceiling your canvas and every
light a brushstroke with the new range of
C-Bus High Powered Series Dimmers.
These dimmers will bring your lighting
plans to life. Create a dramatic landscape
one second or an intimate portrait
the next.
Designed and manufactured by Schneider
Electric there are two distinctive dimmer
models available. The Architectural
Dimmer is designed for museums,
galleries and function centres while the
Professional Dimmer is designed for
restaurants, hotel bars and clubs.
Features:
• Modular individual dimming cards
• Manual by-pass switch
• Built in RCD for overload protection
• Meets AS3000 - 2008 Standards
Contact Schneider Electric for further
information on the art of dimming:
Ph 0508 2547725, or visit the website
www.clipsal.co.nz
CLIPCOM15670
12 CHANNEL
6 CHANNEL
3 CHANNEL
37
Commercial
Dimming
New
2009
C-Bus
Professional Dimmer
Technical Data
L5112D10TP
L5106D10TP
Trailing Edge Models
L5106D20TP
L5103D20TP
L5106D16TP
L5112D10TP
L5106D10TP
L5103D10TP
L5112D5TP
L5106D5TP
L5103D5TP
L5112D3TP
L5106D3TP
Supply Voltage
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
Frequency range
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
Single or three phase supply
3
3
3
3
3
1 or 3
3
1 or 3
1
2
1
Number of channels
6
3
6
12
6
3
12
6
3
12
6
C-Bus Learn Enabled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Maximum incandescent
load per channel
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
Maximum iron core
transformer load per channel
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
Maximum electronic
transformer load per channel
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
Wall or DIN Mounted
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Controllable via
Crestron®*and AMX®**
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Local channel overrides
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Remote channel overrides
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Scene control capable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Mains terminals
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
Supply 1 x
25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load 25mm² Load
1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or 1 x 6mm² or
2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm² 2 x 2.5mm²
Dimensions
713 x 455 x
164mm
451 x 455 x
164mm
713 x 455 x
164mm
713 x 455 x
164mm
451 x 455 x
164mm
289 x 455 x
164mm
713 x 412 x
164mm
451 x 412 x
164mm
289 x 412 x
164mm
713 x 412 x
164mm
451 x 412 x
164mm
Maximum units on a network
(255 Networks)
100
100
100
100
100
100
100
100
100
100
100
C-Bus connections
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
Weight
17.5kg
15kg
17.5kg
25kg
19.5kg
9.5kg
23.6kg
17.5kg
9.6kg
23kg
16.6kg
Approvals
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
Note: Professional Plus and Architectural Dimmers are indent items only.
Please contact Schneider Electric customer care on 0508 254 7725 regarding lead times.
38
New
2009
L5112D10LP
L5106D10LP
L5103D5LP
Leading Edge Models
L5112D20LP
L5106D20LP
L5103D20LP
L5112D16LP
L5112D10LP
L5106D10LP
L5103D10LP
L5112D5LP
L5106D5LP
L5103D5LP
L5112D3LP
L5106D3LP
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
3
3
3
3
3
3
1 or 3
3
1 or 3
1
2
1
12
6
3
12
12
6
3
12
6
3
12
6
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
20A
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
20A
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
20A
20A
20A
16A
10A
10A
10A
5A
5A
5A
3A
3A
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Wall
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
Supply 1 x
25mm² Load
1 x 6mm² or
2 x 2.5mm²
713 x 455 x
164mm
451 x 455 x
164mm
289 x 455 x
164mm
713 x 455 x
164mm
713 x 412 x
164mm
451 x 412 x
164mm
289 x 412 x
164mm
713 x 405 x
115mm
451 x 405 x
115mm
289 x 405 x
115mm
602 x 405 x
115mm
358 x 405 x
115mm
100
100
100
100
100
100
100
100
100
100
100
100
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
3 x RJ45
1 x terminal
block
40kg
27kg
14.5kg
40kg
31kg
21kg
11.5kg
25.6kg
17.5kg
9.5kg
23kg
16kg
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
39
Commercial
Dimming
New
2009
C-Bus
Architectural Dimmer
Technical Data
L5112D10UA
L5106D20UA
L5103D20UA
L5106D16UA
L5103D16UA
L5112D10UA
L5106D10UA
Supply Voltage
240V AC
240V AC
240V AC
240V AC
240V AC
240V AC
Frequency range
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
Single or three phase supply
3
3
3
3
3
3
Number of channels
6
3
6
3
12
6
C-Bus Learn Enabled
Yes
Yes
Yes
Yes
Yes
Yes
Maximum incandescent
load per channel
20A
20A
16A
16A
10A
10A
Maximum iron core
transformer load per channel
20A
20A
16A
16A
10A
10A
Maximum electronic
transformer load per channel
20A
20A
16A
16A
10A
10A
DSI ballasts per channel
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
DALI Control
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Wall or DIN Mounted
Wall
Wall
Wall
Wall
Wall
Wall
DMX512 capable
Yes
Yes
Yes
Yes
Yes
Yes
Controllable via Crestron®*
and AMX®**
Yes
Yes
Yes
Yes
Yes
Yes
Local channel overrides
Yes
Yes
Yes
Yes
Yes
Yes
Remote channel overrides
Yes
Yes
Yes
Yes
Yes
Yes
Scene control capable
Yes
Yes
Yes
Yes
Yes
Yes
Mains terminals
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Dimensions
713 x 455 x 164mm
451 x 455 x 164mm
713 x 455 x 164mm
451 x 455 x 164mm
713 x 455 x 164mm
451 x 455 x 164mm
Maximum units on a network
(255 Networks)
100
100
100
100
100
100
C-Bus connections
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
Weight
17.5kg
11kg
17.5kg
11kg
25kg
17.5kg
Approvals
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
CE RCM
Note: Professional Plus and Architectural Dimmers are indent items only.
Please contact Schneider Electric customer care on 0508 254 7725 regarding lead times.
40
L5106D10UA
L5106D20UA
L5112D5UA
L5103D10UA
L5112D5UA
L5106D5UA
L5103D5UA
240V AC
240V AC
240V AC
240V AC
47 – 53Hz
47 – 53Hz
47 – 53Hz
47 – 53Hz
3
3
1 or 3
1
3
12
6
3
Yes
Yes
Yes
Yes
10A
5A
5A
5A
10A
5A
5A
5A
10A
5A
5A
5A
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Via optional Ballast/
Relay Channel Module
Wall
Wall
Wall
Wall
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
Supply 1 x 25mm²
Load 1 x 6mm² or
2 x 2.5mm²
289 x 455 x 164mm
713 x 412 x 164mm
451 x 412 x 164mm
289 x 412 x 164mm
100
100
100
100
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
3 x RJ45
1 x terminal block
9.5kg
23.6kg
17.5kg
9.6kg
CE RCM
CE RCM
CE RCM
CE RCM
L5103D20UA
Features
>>
Utilises universal dimming technology with automatic
choice of leading or trailing operation
>>
Interchangeable and field replaceable individual
dimming channel modules
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
Support for onboard lighting scenes
>>
>>
>>
>>
>>
>>
>>
>>
>>
Local override switches
Three prioritised emergency auxiliary inputs
Standby generator auxiliary input
Emergency lighting output available on each channel
On-board MCB protection
C-Bus or DMX512 operation modes
Soft start operation
Cool and quiet fanless operation
Thermal overload protection
Over current protection
Short circuit protection
Optional Relay output
Optional DSI output
Optional DALI output
Optional 0-10V DC output
Manual dimmer bypass switch included on channel
modules
Supplied with easy-mount wall bracket
Generous mains supply terminals and load terminals
Selectable (predefined) dimming curves
Installer definable dimming curves
Cross fading scene functions
Channel Status indicators visible from front control panel
Internal and external C-Bus connectors
Tested to and comply with Australian Standard for light
dimmers AS/NZS CISPR 15:2002
41
C-Bus System Units
and Accessories
Pascal Automation Controller
Telephone Interface
5500PACA
C-Bus Pascal
Automation Controller
5100TNZ-BT
Telephone Interface
>>
Provides extended conditional
and real-time event programming for C-Bus.
>>
>>
>>
>>
>>
>>
Programs downloaded to the unit from a PC.
>>
A scene programming tool allows installers to quickly
and easily program scenes into the unit.
>>
A programming wizard provides a GUI based method for
creating basic logic programs.
>>
More complex programs are produced by advanced
users utilising the freeform text programming method.
>>
Programming language based on the standard Pascal
computer language, enhanced with specific commands
related to C-Bus control.
>>
The language supports commands such as:
42
Connects directly to C-Bus.
Powered from C-Bus.
4M DIN modules wide.
2 x RS-232 ports for third-party device control.
A scheduling tool allows time based events to be
programmed into the unit.
- Conditional logic (if then, and, or, not etc)
- Flow Control (for, repeat, while)
- Variables (integer, real, Boolean, character, string)
- Control and monitor C-Bus group addresses
- Control and monitor C-Bus scenes
- C-Bus tag names
- Serial (RS-232) input/output.
>>
Offers a dial in and dial
out facility, permitting
control and status
monitoring for a C-Bus
system via any touchtone phone.
>>
>>
Dimensions 146mm x 146mm x 30mm.
>>
Programmed using a connection to a PC running the
C-Bus telephone interface configuration software.
>>
>>
The unit can also act as a C-Bus PC interface.
It also includes an audio output, so that C-Bus events
can be audibly announced.
Allows C-Bus to be programmed and configured either
locally or from a remote site using a data modem.
5100TMB
Bracket for
mounting to
a StarServe®
enclosure
C-Bus to DALI Gateway
C-Bus Power Supply
5502DAL
DALI Gateway
5500PS
Power Supply, 350mA
>>
C-Bus to DALI Gateway, DIN
rail mounted.
>>
C-Bus power supply, DIN
rail mounted.
>>
>>
>>
4M DIN modules wide.
>>
>>
>>
>>
4M DIN modules wide.
>>
Up to 5 power supplies may be used on any single
C-Bus network.
Dimensions 72mm x 85mm x
65mm.
Supports DALI lamp and ballast failure information to be
available on the C-Bus network.
>>
>>
Capable of controlling up to two DALI networks.
>>
A remote switch input is included to turn all DALI output
channels to the ON or OFF states, irrespective of the
current state of the C-Bus, including no C-Bus.
>>
Incorporates the C-Bus clock signal and
a network burden.
>>
Up to 50 DALI Gateways can be connected to a single
C-Bus network.
>>
Units Draw 32mA from a C-Bus network.
The unit supports DALI group addresses, short addresses
and scenes the DALI global (broadcast) address.
NB: Refer page 70 for detailed application diagrams on this
product.
Dimensions 72mm x 85mm x 65mm.
Supplies 350mA at 18-36V DC to the C-Bus network.
Each power supply supports approximately 18 standard
C-Bus units.
C-Bus PC Interface
5500PC
PC Interface
>>
C-Bus PC interface, DIN
rail mounted.
>>
>>
>>
>>
4M DIN modules wide.
>>
>>
Units Draw 32mA from a C-Bus network.
Dimensions 72mm x 85mm x 65mm.
Features two connections to C-Bus (2 x RJ45 sockets).
Features three connections to RS232 (2 x RJ45 and
1 x DB9 sockets).
Available with USB port (5500PCU).
43
C-Bus System Units
and Accessories
C-Bus Ethernet
Network Interface
5500CN
C-Bus Ethernet
Network Interface
>>
C-Bus Ethernet
network interface,
DIN rail mounted.
>>
>>
>>
>>
4M DIN modules wide.
>>
Features 2 x C-Bus RJ45 connections and
1 x Ethernet RJ45 connection.
>>
The unit requires an external 9-12V DC power
pack supplied.
Dimensions 72mm x 85mm x 65mm.
Provides a two-way C-Bus to Ethernet network interface
Allows C-Bus commands to be distributed via
a 10 Base-T Ethernet (TCP/IP) network.
C-Bus Network Bridge
C-Bus BACnet Gateway
The C-Bus BACnet Gateway is an embedded device that
provides a field bridge between the C-Bus lighting control
system and a building management system that support the
BACnet open protocol.
About BACnet
BACnet is a communication protocol for a Building
Management System (BMS). This protocol is a set of rules
governing how data is exchanged over a network.
Connecting C-Bus to BACnet
When connecting the C-Bus system to a BACnet compliant
building management system, the BMS user refers to a
mapping table for the points that are connected between the
two systems.
The BACnet Gateway contains the software that enables
C-Bus and BACnet objects to interrelate. The pre-configured
mapping table in the C-Bus BACnet Gateway provides one
full C-Bus Lighting Application of 255 group addresses from
a single application address.
If more than one application address is required, or more
than 255 group addresses are required to be mapped, then
additional gateway devices will be required.
The pre-configured mapping in the gateway provides the
following connectivity.
5500NB
C-Bus Network Bridge
>>
C-Bus network bridge,
DIN rail mounted.
>>
Based on a 4M DIN
module.
>>
>>
>>
Dimensions 72mm x 85mm x 65mm.
44
Provides a two-way C-Bus to C-Bus network interface.
Units Draw 18mA from a C-Bus network.
>>
255 BACnet analogue value objects allow BACnet to
read analogue values from the C-Bus system.
>>
255 BACnet analogue value objects allow BACnet to
write analogue values to the C-Bus system.
>>
255 BACnet binary value objects allow BACnet to read
binary values from the C-Bus system.
C-Bus Wireless
Gateway
C-Bus Cable
5800WCGA
C-Bus Wireless Gateway
>>
Allows seamless communication
between a wired C-Bus network and
a C-Bus Wireless Network.
>>
>>
Desktop or wall mounted.
>>
Power for the Gateway is provided by the wired C-Bus
network, no additional power source is required.
>>
The connection to a C-Bus Wireless network is
accomplished by a C-Bus Learn Mode operation.
>>
5005C305B
C-Bus Category 5, 4 pair,
UTP cable, 305 metres
>>
4 pair, Category 5, unshielded
cable with a unique outer
colour sheath specifically designed
for the C-Bus system.
>>
A maximum of 1000 metres of cable is permitted on any
one C-Bus network.
>>
The connection to a C-Bus Cat-5 wired network requires
the use of the C-Bus Toolkit software.
Two pairs are used for the C-Bus connection C-Bus
positive (blue + orange) and C-Bus negative (blue/white
+ orange/white).
>>
>>
The Gateway supports routing of messages into and
through both wired and wireless networks.
The C-Bus cable must be segregated from the mains
cable in C-Bus installations.
>>
>>
Messages on each network (such as button presses)
can be passed through to the adjacent network.
C-Bus cable has a mains rated outer sheath and
Standard Cat 5 cable does not have this rating.
>>
Suitable for use inside electrical enclosures.
A C-Bus Cat-5 cable connected to the wired C-Bus
network is plugged into an RJ45 socket at the rear of
the Gateway.
C-Bus Network Analyser
5100NA
C-Bus Network Analyser
The Network Analyser is
a tool used to measure
various C-Bus system
parameters:
- Power Available
- Clock Signal Present
- Excess Voltage
- Add/Remove Burden
- Excess Cable Indication.
>>
Dimensions 60.5mm x
120mm x 30.3mm.
>>
Measures capacitance, burden, clock signal
and network voltage.
>>
The network analyser is powered from C-Bus and
is supplied with a pair of leads.
C-Bus Barcode Reader
5100BCS
Barcode Reader,
USB connection,
for use with C-Bus
Toolkit software
45
Multi-Room
Audio System
System Overview
The C-Bus Multi-Room Audio System allows users to listen
to and control audio sources from convenient locations around
the home. The system is both simple to install and easy
to use.
The C-Bus Multi-Room Audio System allows a number of
different system layout options. This flexibility allows for a
wide range of customer needs and installation requirements.
Two example schematics are shown opposite.
The system has been designed utilising new digital audio
distribution technology, in conjunction with core technology
for system communication and integration.
Option A
This basic option allows a single audio source to be available to
a number of C-Bus Audio Amplifiers and to be controlled from
convenient locations around the home (via any combination
of C-Bus input devices). This option requires one Cat-5 cable
for the audio distribution. This cable is cascaded between
each Audio Amplifier.
This digital audio distribution technology allows for noise
and interference-free audio reproduction, whilst the C-Bus
technology allows the audio products to be seamlessly
integrated and used with all existing C-Bus products.
For example, volume can be controlled from the same C-Bus
switch or touch screen controlling lighting.
In addition, the system allows any input audio source to be
made available in any audio zone. Changes to the input
audio source can easily be made by the user from a local
C-Bus device at any time, regardless of where the audio
source equipment (e.g. CD player) is physically located.
It is compatible with most audio sources and it accommodates
standard stereo line level analogue inputs as well as digital
audio TOS link inputs.
Infrared signals from hand-held remote controls can be routed
through the system by connecting IR targets and emitters.
IR commands can also be stored by the system and activated
by programmed C-Bus commands.
46
Option B
This option allows more flexibility. Multiple audio sources are
made available to all audio zones, with all the audio sources
selectable on a zone-by-zone basis via C-Bus Input Devices.
This option requires a separate (star wired) Cat-5 audio cable
to each Audio Amplifier in a zone.
Typical Multi-Room Audio Wiring Topology
Option A
‘See note
1 & 2 below’
Option B
Note 1
The C-Bus Matrix Switcher is able to supply a limited amount
of power to the Audio Amplifiers, as the system shares power
available via the Cat-5 audio network.
Note 2
Adding a power supply (5600P24/3750AU) to each
amplifier will change the output power rating from
10W to 25W RMS.
47
Multi-Room Audio System
Audio Matrix Switcher
Audio Distribution Unit
560884
Audio Matrix Switcher, C-Bus
enabled, four stereo audio input
sources and 8 digital audio
output sources.
560011
Audio Distribution Unit,
one stereo audio input source
and one digital output source
>>
Digital audio distribution technology, for noise-free
audio reproduction.
>>
>>
Four stereo analogue audio source inputs.
>>
Eight digital audio zone outputs (~45m for each star
wired output).
>>
Cat-5 cable connection between Matrix switcher
and amplifiers.
>>
>>
>>
>>
Two mono annunciation inputs.
>>
C-Bus infrared output (2 zones) for third-party equipment
control.
>>
>>
Reticulated IR support.
>>
C-Bus messages control selection of
input/output routing.
>>
>>
>>
>>
>>
Contains a C-Bus PC interface.
>>
Dimensions: 425mm x 289mm x 75mm.
48
Audio sources switched via any C-Bus input device or
via the control panel on the front of the Matrix switcher.
Voice annunciation of channel changes (selectable).
One fibre-optic SPDIF input (digital audio compatible)
One custom digital input to allow cascading of units or
for connecting an Audio Distribution Unit giving
1 additional stereo analogue input.
>>
Distributes a single stereo audio source to C-Bus Audio
Amplifiers via a digitised signal over Cat-5 cable.
>>
>>
>>
>>
>>
Does not require any C-Bus programming.
One stereo analogue audio source input.
One digital audio output (cascadable to multiple zones).
Output can be looped between C-Bus Audio Amplifiers.
Dimensions: 165mm x 50mm x 40mm.
5600P24/500AU
External power supply for audio
distribution unit, switch mode,
24V DC, 500mA (only required
if 560011 used to provide an
additional digital input for Matrix
Switcher)
User interface consisting of LCD display and tactile
feedback switches.
Internal C-Bus PSU.
Internal 4A PSU for the amplifiers.
Configuration set up through or USB.
Control via C-Bus input devices, such as C-Bus wall
switches, touch screens, etc.
5600TEE
RJ45 Bypass Tee Connector for
amplifiers with common digital feed
that require individual control
Audio Amplifiers
560125D/2
25 Watt/channel (RMS) stereo
audio amplifier, C-Bus enabled,
desktop-mount version
5600P24/3750AU
External power supply
for audio amplifier, switch
mode, 24V DC, 3.75A
560125R/2
25 Watt/channel (RMS)
stereo audio amplifier, C-Bus
enabled, remote-mount version
>>
Used in conjunction with the C-Bus Audio Matrix
Switcher or the Audio Distribution Unit.
>>
Controllable via C-Bus input devices, such as C-Bus
wall switches and touch screens.
>>
Volume, bass, treble, balance controlled by C-Bus input
devices.
>>
>>
Quiet digital audio design.
>>
>>
Can be cascaded off one Digital Audio Cat 5 input.
>>
Desktop Amplifier includes power on/off, mute, volume
and source select buttons and an infrared target for
remote control. Also includes 3.5mm stereo head
phone jack.
>>
>>
Set up via C-Bus Toolkit software
>>
>>
>>
>>
Stereo 25W RMS per channel – Remote and desktop
mounted units (when power supply fitted).
Pre-amp output stage for connecting to a third-party
power amplifier.
Signal source either:
-
-
-
Distributed digital
Locally connected line-level analogue
Fibre-optic (TOSlink) SP/DIF (16bit, 48kHz).
IR Target connection for reticulated IR support.
High efficiency, ~70% at full power.
Dimensions (desktop): 181mm x 216mm x 75mm.
Dimensions (remote): 175mm x 209mm x 71mm.
49
Multi-Room Audio System
Speakers
In-wall and
In-ceiling Speakers
>>
Perfect for home theatre and multi-room
audio applications.
>>
Available with polypropylene or kevlar drivers, providing
quality sound in all applications.
>>
Flush mount design ensures only the front face of the
speaker is visible and is flush with the wall/ceiling –
inside of the wall/ceiling acts as the enclosure .
>>
Provide great sound without losing valuable floor space.
In-wall Speakers
5600IWP
Flush mounted speakers
(pair), rectangular, in-wall,
polypropylene drivers
5600IWK
Flush mounted speakers
(pair), rectangular, in-wall,
kevlar drivers
>>
>>
>>
>>
>>
>>
50
Sensitivity: <88dB (polypropylene), <91dB (kevlar).
Frequency response: 50Hz – 20KHz (polypropylene),
49Hz – 20KHz (kevlar).
Power output: 60W.
Impedance: 8 ohms.
Dimensions (rim): 305mm x 220mm.
Colour: white.
In-ceiling Speakers
Outdoor Speakers
5600ICP
Flush mounted speakers
(pair), circular, in-ceiling,
polypropylene drivers
5600ODP
Outdoor/shelf top speakers (pair),
polypropylene drivers
5600ICK
Flush mounted speakers
(pair), circular, in-ceiling,
kevlar drivers
>>
Designed to accurately reproduce high fidelity music
in an outdoor environment.
>>
Long lasting design incorporating rigid, high-impact
plastic cabinets, polypropylene drivers, and
powder-coated metal grilles.
>>
>>
>>
>>
>>
>>
Sensitivity: <88dB.
>>
>>
>>
>>
>>
>>
Sensitivity: <90dB.
Frequency response: 45Hz – 20KHz.
Power output: 60W.
Frequency response: 55Hz – 20KHz.
Power output: 35W.
Impedance: 8 ohms.
Colour: white and black.
Water resistant*.
*Outdoor speakers are not waterproof. Never install
outdoor speakers where they are directly hit by rain.
Under a porch, eave, or overhang provides a more
suitable environment.
Impedance: 8 ohms.
Dimensions (rim diameter): 240mm.
Colour: white.
51
Infrared Distribution
System
8050 Series
The 8050 product series forms a flexible, cost effective multizone Infrared Distribution System, which can be used in isolation
or as part of the StarServe Home Networking range.
Most homes have audio/visual systems that incorporate infrared
control to operate source functions such as play, stop, channel
up and down etc. The 8050 series Infrared Distribution System
allows the control of source functions from different rooms or
the control of source equipment located in solid cabinetry.
A connection from the Zone A or Zone B connection point
on a 8050EJ to a 8050TJ unit is made via Cat-5e cable,
which terminates in the RJ45 sockets of both units. Both the
8050EJ (Zone B only) and 8050TJ junction boxes provide a
further RJ45 socket to enable multiple junction boxes to be
connected into the IR Distribution Network.
Targets can then be plugged into the 8050TJ and placed at
desired locations around the home.
Additionally, the 8050 series Infrared Distribution system provides
two independently controlled IR zones for installations where
multiple set-top-boxes may be installed, with matching remotes.
The system can be expanded to have more IR targets and IR
emitters as required.
This allows the homeowner to only control particular source
equipment in certain areas of the home. For example, Set Top
Box 1 can be controlled in the Bedrooms and Lounge; Set Top
Box 2 can only be controlled in the Family Room and Kitchen.
Typical System Diagram
demonstrating how the individual
components can be installed to form
an IR Distribution System.
IR emitter leads (8050LD or 8050/2LD) are connected to
either Zone A (1st Zone) or Zone B (2nd Zone) of the 8050EJ
and are run to the desired source equipment, where the head
of the lead is positioned on or near the IR receiver.
52
IR Distribution System
Components
IR Distribution System Components
IR Distribution System Emitter Junction Box
The 8050EJ has been designed to sit on top of or near
the AV equipment. It is the main distribution hub of the IR
Distribution Network.
The unit connects to the distribution system as follows.
IR Emitter Ports – There are five output connections for
IR Emitter leads. Emitter Output 1 is dedicated for Zone A,
Emitter Output 5 is dedicated to Zone B, Emitter Outputs 2,3
and 4 can be used by either zone.
RJ45 Connections – The Emitter Junction Box has three RJ45
connections, allowing Target Junction boxes to be networked
via a Cat-5 connection. RJ45 Output 1 is dedicated to Zone
A, while Zone B has the ability to supply two Target Junction
Boxes, via RJ45 Outputs 2 and 3.
Local target connections – Both Zone A and B have the
ability to power one locally placed target each directly.
IR Distribution System Target Junction Box
The 8050TJ acts as a termination point
between an IR Target and the 8050EJ. It
has the ability to enable the installation to
loop to the next 8050TJ.
8050ST - IR Distribution
System Shelf Top Target
Suitable for use on top of TV’s
or inside Stereo cabinets
8050TT - IR Distribution
System Tube Target
Suitable for use in speaker
grills and air conditioning vents
8050FT - IR Distribution
System Flat Target
Can be mounted behind
Slimline, Classic and 2000
series grid plates
8050LD
IR Emitter Lead, single
8050/2LD
IR Emitter Lead, dual
The 8050TJ can be mounted onto a
standard Wall Plate as well as inside a
cabinet or wall stud.
IR Targets
These targets contain an infrared receiver array,
designed to receive and relay IR data from required locations
to the centrally located Emitter Junction Box. An Infrared
Target may be installed in each room of the house, allowing
the user to control audio/visual equipment (such as VCRs,
Cable TV Decoders, CD Players etc) from each required
location.
There are three types of targets that can be used on the IR
Distribution system.
Product Range
Catalogue
Number
Description
8050EJ
IR Distribution System Emitter Junction Box
8050TJ
IR Distribution System Target Junction Box
8050ST
IR Distribution System Shelf Top Target
8050TT
IR Distribution System Tube Target
8050FT
IR Distribution System Flat Target
8050LD
IR Emitter Lead, single
8050/2LD
IR Emmiter Lead, dual
For more information refer to the StarServe Installation Guide NZCLIPSTRSRVIG1008.
53
C-Bus Software
C-Bus Toolkit Software
Piced Software
C-Bus Toolkit software is a PC-accessible C-Bus network
configuration and programming utility. It allows the installer to:
Programming Interface for C-Bus Embedded Devices
>>
Piced is used to configure the following devices to meet the
user’s requirements:
>>
Connect directly to an installer C-Bus network via
a C-Bus PC interface unit to synchronise logical and
physical C-Bus customer site data.
Configure the C-Bus network to define the C-Bus
architecture of the customer site and ensure C-Bus units
can communicate with each other.
>>
>>
>>
C-Touch black and white touchscreen.
Colour C-Touch touchscreen.
Pascal Automation Controller (PAC).
>>
Program and commission
the customer solution.
The Piced software features include:
>>
Save, backup and
restore sites. C-Bus
Toolkit has a database
for creating and
storing customer
site programming
as projects.
>>
>>
>>
>>
>>
Display of many components on many pages.
Scenes for the control of many loads together.
Schedules for the automatic control of loads.
Access control to provide security.
Irrigation control.
Marpa Software
Multi Room Audio Rapid Programming Application
Marpa software is used to configure the C-Bus Multi
Room Audio Matrix Switcher unit and is freely available
from the Integrated Systems website. It requires the use
of a USB port on the PC to connect to the Matrix Switcher.
Marpa software requires that the C-Bus Toolkit is installed.
For more information or to download these software packages, please refer to: www.clipsal.co.nz/downloads/cbus_software_downloads
54
Tica Software
Circa Software
Telephone Interface Commissioning Application
C-Bus Infrared Commissioning Application
Tica software is used to configure the C-Bus Telephone
Interface (CBTI). It requires the use of a RS232 serial port on
the PC to connect to the CBTI. Tica software requires that
C-Bus Toolkit is installed.
Circa software is used to commission C-Bus Infrared Devices
(5034NIRT). The software allows the user to select IR codes
and assign them to particular output channels on an Infrared
Device and make associations between IR codes and C-Bus
events. The user can import IR device files created by the
5100RP Infrared Reader device. Circa software requires
that C-Bus Toolkit is installed.
55
C-Bus Software
HomeGate Software
C-Gate® Server Software
The HomeGate application software provides a powerful
but simple-to-use interface to C-Bus via a standard PC.
HomeGate provides scheduling, manual control and
monitoring of a domestic C-Bus system from a PC running
Windows 98, 2000, NT, ME or XP. HomeGate comprises of
a project editor, real-time monitoring and control, a real-time
scheduler, security and access control and internet access.
It also includes help and support documentation.
C‑Gate® Server is a software suite that monitors and controls
the C-Bus Control and Management System. It has been
produced to allow third-party software developers and
existing Building Management Systems to interface to C-Bus
at a high level, allowing high-speed control and monitoring
of C‑Bus®.
5000SDHG2/4
HomeGate application
V4 Software c/w USB
dongle, 2 network licence
C-Bus OPC Server
5000SDHG10/4
HomeGate application
V4 Software c/w USB
dongle, 10 network licence
Schedule Plus Software
Schedule Plus application software provides a powerful and
easy to use interface to C-Bus via a standard PC. Schedule
Plus has been developed specifically for commercial and
industrial applications. It provides scheduling, manual control
and monitoring of a C-Bus system from a PC running Windows
98, 2000, NT, ME or XP.
5000SPSP2/4
Schedule Plus application
software V4 c/w USB dongle,
2 network licence
5000SPSP10/4
Schedule Plus application
software V4 c/w USB dongle,
10 network licence
50000SPSPU/4
Schedule Plus application
software V4 c/w USB dongle,
unlimited network licence
56
The OPC server is a software package that enables
communication between C-Bus networks and systems
containing an OPC client, such as Citect Facilities.
The C-Bus OPC Server makes it possible to transmit lighting
type application messaging between a C-Bus network and
an OPC Client. The customer can:-
>>
Transmit the lighting status and levels to the OPC Client
from a C-Bus network.
>>
Control lighting status and levels by sending commands
from the OPC Client to the C-Bus network.
5000SDOPC2/1
2 network licence dongle for C-Bus OPC Server Software
5000SDOPC10/1
10 network licence dongle for C-Bus OPC Server Software
5000SDOPCU/1
Unlimited network licence dongle for C-Bus OPC Server
Software
5000SDINST/1
Installer Dongle for C-Bus software, unlimited networks
Citect Facilities
Citect Facilities enables Property Owners and Facility
Managers to lower operating costs, improve tenant services
and protect existing and future facilities investments. This
is achieved by providing centralized visibility to control all
facilities systems from multiple vendors and sites, across a
single building to very large multiple site applications.
Open architecture, system flexibility and unrivalled
connectivity, combined with easy to-use configuration tools,
allow end users and independent system integrators to
rapidly develop and deploy applications of any size.
Open access delivers
“Integrated systems”
Citect Facilities provides open interfaces to integrate the
many systems required for a complete facilities monitoring
system. While it is traditional for building automation projects
to include different systems for HVAC, access control, fire
detection or lighting, this leaves the user with a number of
different systems that they need to manage and reconcile in
order to get a complete picture of their facility. Citect Facilities’
open interfaces enable information from all these systems to
be combined and delivered through a single interface to the
user resulting in a simpler and more manageable system.
Display
Client
Pocket
Client
Web
Client
Features
>>
>>
>>
>>
Time based Scheduler
>>
>>
>>
Industry specific symbols
Zero maintenance, fully functional web client
Option for mobile pocket technology
Process analyst – integrated display of trends and
alarms
Multiple screens (up to 6 screens per work station)
Access to facilities-specific devices and an extensive
range of PLC controllers
Please note that Citect Facilities is not a C-Bus product.
Citect is part of Schneider Electric. For further details and
training schedules, please contact Schneider Customer
Care 0800 652 999.
Manager
Client
Manager
Client
Pocket Client
Intranet
Pocket Client
Intranet
CitectFacilities Server
Web Client
all
Firewall
Web Client
ETHERNET
9-12 V
Ethernet
C-Bus / Unit / Comms
Network Interface
C-Bus CONNECTIONS
To C-Bus Network
For more information contact Schneider Electric on 0800 652 999 or visit www.schneider-electric.co.nz.
12v
ETHERNET
57
C-Bus Wireless System
The C-Bus Wireless product range incorporates a family of
C-Bus Radio Frequency (RF) devices, including wall plates,
plug adaptors, remote control and a gateway to Cat-5 wired
C-Bus units.
C-Bus Wireless wall switches are designed to easily replace
standard, 240V wall switches. They incorporate patented
C-Bus technology and are two wire devices requiring no
neutral (240V AC active and load connections only).
All C-Bus Wireless units incorporate unique Learn Mode
functions for programming devices. Wall switches, plug
adaptors and the gateway unit can also be programmed via
the C-Bus Toolkit software. Multiple C-Bus Wireless units can
be linked into a common network using Learn Mode or the
C-Bus Toolkit software.
Associations can be created between buttons on multiple
units, so that a button pressed on one unit will operate a
button on another (and the connected lights or other electrical
devices).
C-Bus Wireless units include scene capabilities, which allow
the user to perform a series of actions across multiple outputs
by pressing a single button. For example, on arrival home
a home owner could use a scene to switch on lights in the
hallway, kitchen and lounge, and also switch on a heater.
Programming a C-Bus Wireless unit via C-Bus
Toolkit software
The diagrams below show two of the many possible basic
C-Bus Wireless unit installations. Room A uses stand-alone
units, which can be switched via the Wireless remote control.
Room B uses networked units where buttons on one unit can
operate other units or trigger scenes.
Room A Stand-alone C-Bus
Wireless Units
Grouping C-Bus
Wireless Units via
Learn Mode
Room B Networked C-Bus
Wireless Units
58
Basic Operation
Buttons on a Wireless wall switch or plug adaptor are
organised in pairs that control the output channels (local
control buttons). Remaining pairs (free buttons) are used to
control outputs on other units when multiple C-Bus Wireless
units are configured as part of a network. For example,
the figure to the right shows a 6 button, 2 channel Saturn
Wireless dimmer wall switch. Its buttons perform the
following functions:
>>
Buttons 1 and 2 control the first channel. (A quick press
on either button toggles the channel on or off. A long
press on button 1 or 2 dims down or up respectively.)
>>
>>
Buttons 3 and 4 control the second channel.
Buttons 5 and 6 are unused when the unit is used as a
stand-alone unit. They may be used to control outputs on
other units when part of a multi-unit network.
When a C-Bus Wireless wall switch or plug adaptor unit is
first installed, it functions as a stand-alone unit. In this basic
default mode, the unit functions as a dimmer or switch,
depending on the model.
C-Bus Wireless plug adaptors have one output channel
(a single, 240V AC socket) and two buttons. Wall Switch units
are available in one or two output channel versions, with two,
four, six buttons. Each channel controls one or more lights or
other electrical devices connected to its output.
59
C-Bus Wireless System
C-Bus Wireless Networks
To experience the full capabilities of wireless operation, C-Bus
Wireless units must be linked together to form a network.
To communicate with each other, units within the same
network should be located within 15 to 20 metres of each
other. This distance depends on building materials used.
Up to 30 units may be connected within the same C-Bus
Wireless network.
Mode 1
Stand-alone Mode
In this mode, C-Bus Wireless wall switches and plug adaptors
acts as stand-alone dimmers or switches and make no use of
the inbuilt wireless capabilities. No setup is required for this
mode, plug adaptors simply plug into the mains, and Wireless
wall switches are installed by a licensed electrician in place
of existing wall switches. The buttons on the units control the
local dimming or switching channels of the unit only.
Mode 2
Simple Remote Controlled Mode
In this mode, a C-Bus Wireless wall switches acts as a
stand-alone dimmer or switch and a C-Bus Wireless remote
control operates the wall switch from a distance. This mode
is simple to set up and is suitable for small installations where
networking is not needed. C-Bus Wireless wall switch or plug
adaptor units are controlled using a C-Bus Wireless remote:
In this mode, the buttons on the Wireless wall plate control
the local dimming or switching channels of the unit, and the
remote control is linked to buttons on a wall switch using a
Learn Mode operation. No PC is required.
C-Bus Wireless Network
Security
C-Bus Wireless units can optionally use 128 bit-encrypted
messages to communicate with each other. This results in a
highly secure network.
Nearby C-Bus Wireless
Networks
It is possible to have several separate networks present
alongside each other without interfering, as each separate
C-Bus Wireless network has an automatically assigned,
unique ‘House Code’.
C-Bus Wireless Modes of
Operation
C-Bus Wireless units have five major modes of operation.
60
Mode 3
Networked Mode
In this mode, a C-Bus Wireless wall switch acts as a
dimmer or switch and multiple C-Bus Wireless units can be
linked to each other with the C-Bus Wireless technology.
This mode is simple to set up, and is suitable for more
complex installations. In this mode, local control buttons
control the dimming or switch channel of the unit, and may
also control other C-Bus Wireless units. Free buttons can
control the dimmer or switch channels of other units via a
C-Bus Wireless network established using Learn Mode
operations. The operation of buttons is set using Learn Mode
operations or using the C-Bus Toolkit software.
Mode 4
Networked with Remote
In this mode, a C-Bus Wireless wall switch acts as a dimmer
or switch and multiple C-Bus Wireless units can be linked to
each other with the C-Bus Wireless technology. Local control
buttons control the dimming or switch channel of the unit, and
may also control other C-Bus Wireless units. Free buttons
can control the dimmer or switch channels of other units via
a C-Bus Wireless network established using Learn Mode
operations or C-Bus Toolkit software. Buttons on the Wireless
remote are linked to wall switch and plug adaptor buttons
as desired.
Mode 5
Networked mode in combination with Cat-5 wired
C-Bus units
The C-Bus Wireless gateway is used to link a C-Bus Wireless
network to a C-Bus Cat-5 wired network. It is functionally
equivalent to a C-Bus network bridge. Using the gateway,
C-Bus Wireless and Cat-5 networks can communicate and
interact with each other. Both Wireless and Cat-5 networks use
the same command structure, and are 100% compatible.
61
C-Bus Wireless System
C-Bus Wireless Wall
Switch Range
>>
Allow existing, 240V AC operated wall switches
to be replaced with C-Bus Wireless wall switches
containing C-Bus Wireless technology.
>>
Communicate with other C-Bus Wireless devices
using radio frequency wireless messaging and form
a C-Bus Wireless network.
>>
Switch buttons enable control of the load/s directly
connected to the wall switch and can also control
loads connected to other C-Bus Wireless devices.
>>
Each switch button can be programmed to function
as an on/off switch, a dimmer, or can issue a scene,
as well as a number of other options.
>>
Can be controlled via C-Bus Cat-5 wired input units
(via a gateway unit), such as touch screens.
>>
>>
>>
Unique C-Bus Wireless house code.
>>
Programmable via C-Bus Learn features or via
C-Bus Toolkit software.
>>
>>
Available in 1 channel and 2 channel versions.
>>
Relay unit, 1 channel 8A (fluorescent) rating and
2 channel 4A (fluorescent) per channel.
>>
>>
Available Saturn style, white glass only*.
Saturn Style
2 Button
4 Button
128-encrypted communications.
2-Wire connection – active and load (no neutral
required).
6 Button
Leading Edge and Trailing Edge dimming units,
1 channel 500VA and 2 channel 250VA per channel.
75 . 0 mm
Available in 2, 4 & 6 button configurations.
116 . 0 mm
6 6 . 0 mm
3 0 . 0 mm
* Black fascias are available on request.
62
51. 0 mm
C-Bus Wireless Selection Chart
Relay
Dimmer – Leading Edge
Dimmer – Trailing Edge
2 Button 1 Channel
5882R8F1AA,GF
5886R8F1AA,GF
5882D2T1AA,GF
2 Button 2 Channel
N/A
N/A
N/A
4 Button 1 Channel
5884R8F1AA,GF
5884D2L1AA,GF
5884D2T1AA,GF
4 Button 2 Channel
5884R4F2AA,GF
5884D1L2AA,GF
5884D1T2AA,GF
6 Button 1 Channel
5886R8F1AA,GF
5886D2L1AA,GF
5886D2T1AA,GF
6 Button 2 Channel
5886R4F2AA,GF
5886D1L2AA,GF
5886D1T2AA,GF
1 Channel Relay variants are rated at 8 amps
2 Channel Relay variants are rated at 4 amps
1 Channel Dimmer variants are rated at 500 watts
2 Channel Dimmer variants are rated at 250 watts
Black replacement glass fascia’s are available on request.
- 5082F-680
- 5084F-680
- 5086F-680
C-Bus Wireless wiring diagrams
N ote: The LOAD terminals on 1 channel dimmer units are internally linked
Total maximum load is 5 00 W, 2 A
Neutral
LOAD
LINE -
Active/Line
E58xxD2L1TA Series
THIS
WAY
UP
LOOP -
Load
Neutral
(Optional)
LOAD 2 -
1 A:
Load
Compatible Loads
M
LOOP -
2 A:
Compatible Loads
THIS
WAY
UP
Neutral
(Required)
LOAD 1 LINE -
Active/Line
E58xxD1T2TA Series
Wall Switch Dimmer Unit
Leading Edge Phase Control
220–240 V , 50 Hz
Maximum Load Per Channel: 2 A
RF Frequency: 433.92 MHz
Patent Pending
Wall Switch Dimmer Unit
Trailing Edge Phase Control
220–240 V , 50 Hz
Maximum Load Per Channel: 1 A
RF Frequency: 433.92 MHz
Patent Pending
1 Channel Dimmer
2 Channel Dimmer
M
2 A:
Neutral
4 A:
LINE -
Active/Line
Compatible Loads
LOOP -
8 A:
8 A:
Load
LOOP LINE (Required)
LOAD 1 -
LOAD
*
THIS
WAY
UP
* Off Leakage 10 mA
THIS
WAY
UP
* Off Leakage 10 mA
4 A:
Compatible Loads
2 A:
M
N ote: The LOAD terminals on 1 channel relay units are internally linked
Total maximum load is 2 00 0 W, 8 A
*
(Required)
LOAD 2 -
Neutral
Neutral
µ
E58xxR8F1TA Series
E58xxR4F2TA Series
Wall Switch Relay Unit
220–240 V , 50 Hz
Maximum Load: 8 A
RF Frequency: 433.92 MHz
Patent Pending
Wall Switch Relay Unit
220–240 V , 50 Hz
Maximum Total Load: 8 A
RF Frequency: 433.92 MHz
Patent Pending
1 Channel R elay
Active/Line
Load
2 Channel R elay
63
C-Bus Wireless System
C-Bus Wireless Plug Adaptors & Dimmers
>>
Allow devices normally plugged into 240V AC
general purpose outlets (for example, lounge
or bedside lamps) to be controlled using C-Bus
Wireless technology.
>>
Communicate with other C-Bus Wireless devices
(such as Wireless wall switches) using radio
frequency wireless messaging and form a
C-Bus Wireless network.
>>
C-Bus Wireless plug adaptors plug into existing
power outlets, and the device to be controlled
via C-Bus Wireless then piggybacks into the plug
adaptor. No additions or alterations to existing wiring
are required.
>>
>>
Plug into a standard general purpose electrical outlet.
>>
Integral, easily accessible control/override/
programming buttons.
>>
Can be controlled via C-Bus Cat-5 wired input units
(via a gateway unit), such as touch screens.
>>
>>
>>
Unique C-Bus Wireless house code.
64
5812D3L1AA
C-Bus Wireless plug adaptor,
1 channel leading
edge dimmer, 3A
Available in leading edge dimming and trailing edge
dimming units, as well as a relay output version.
128-encrypted communications.
Programmable via C-Bus Learn features or via
C-Bus Toolkit software.
5812D2T1AA
C-Bus Wireless plug
adaptor, 1 channel trailing
edge dimmer, 2A
Relay
C-Bus Wireless Remote
Control Unit
5888TXBA
C-Bus Wireless
hand-held remote
control unit with holder
5812R10F1AA
C-Bus Wireless plug adaptor,
1 Channel Relay, 10A
5080TXC
C-Bus remote
control holder (spare)
>>
Allows control of buttons on C-Bus Wireless wall switch
and plug adaptor units remotely.
>>
>>
Utilises radio frequency (RF) communication.
>>
Capable of controlling up to 10 separate wall switch
or plug adaptor buttons.
>>
A single button on a wall switch or plug adaptor can be
controlled by up to two C-Bus Wireless remote controls.
>>
Buttons are organised in two banks of five buttons.
Banks are alternately selected by pressing the
‘Shift’ button.
>>
‘Up’ and ‘Down’ buttons allow dimming of the level
associated with the last button selected (on dimmer units).
>>
‘All Off’ button provides a convenient way to switch off all
buttons associated with the remote control unit.
>>
C-Bus Wireless Groups and Scenes can be controlled
from the remote.
>>
>>
LCD screen and buttons incorporate a blue LED backlight.
>>
Supplied with pre-labelled stickers for identification
of common areas i.e. kitchen, lounge, dining etc.
>>
20-25m range (typical).
Does not need to be pointed directly at the unit
being controlled.
Each control button incorporates a clear window for
button labelling.
65
C-Bus
Typical Schematics
Residential
66
Commercial High Rise Building
67
10 amp
240 Vac
R-03 LOAD
R-01 LOAD
L5504RVF
R-04 LOAD
R-02 LOAD
C-Touch
PSU
D-04 Analogue op 4
D-02 Analogue op 2
C-Bus Relay Unit
4 channel module
D-03 Analogue op 3
D-01 Analogue op 1
L5504AMP
C-Bus Analogue
Output Unit
4 channel module
116m
Single cable legnth
(= max.distance from PS)
174m
2 x 0.75 mm2
300m
2 x 1.5 mm2
1-10 volt control circuits
up to 20 ballasts per
channel
232m
2 x 1.0 mm2
Supervisory C-Bus control from any networked C-Bus device or PC
based software package.
2 x 0.5 mm2
Cable cross-section mm2
Analogue (0-10V)
Control
Analogue
Dimming
C-Bus Cat5e Network
68
240 Vac supply
69
240 Vac
size to suit load
C-Touch
PSU
size to suit load
5 amp
C-Bus Cat5e Network
Essential PS
Non Essential PS
L5508DSI
116m
Single cable legnth
(= max.distance from PS)
174m
2 x 0.75 mm2
300m
2 x 1.5 mm2
DSI control circuits
up to 100 ballasts per
channel
232m
2 x 1.0 mm2
Supervisory C-Bus control from any networked C-Bus device or PC
based software package.
2 x 0.5 mm2
Cable cross-section mm2
2 wire (figure 8) DSI control
240Vac lighting circuits
wired as
un-switched circuits.
C-Bus DSI Gateway
8 channel module
DSIControl
Control
DSI
70
DALI
PSU
Note: The DALI Power Supply
Units (PSU) to be provided by the
ballast manufacturer.
DALI
PSU
DALI
PSU
5500PS
C-Bus Power
Supply – 350mA
5 amp
5502DAL
N
A/L
C-Bus CONNECTIONS
C-Bus
UNIT
Note: The DALI Power Supply
Units (PSU) to be provided by the
ballast manufacturer.
DALI
PSU
2 Channel DALI
Gateway
size to suit
load
size to suit
load
5502DAL
2 Channel DALI
Gateway
size to suit
load
size to suit
load
Power Supply
C Bus
DALI
Group #1
DALI
DALI
DALI
DALI
DALI
DALI
Group #2
DALI
DALI
DALI
174 m
DALI
DALI
2 x 0.75 mm2
DALI
DALI
DALI
DALI
232 m
2 x 1.0 mm2
DALI
DALI
300 m
2 x 1.5 mm2
DALI
DALI
C-Touch
PSU
240 Vac
Supervisory C-Bus control from any
networked C-Bus device or PC based
software package.
C-Bus Cat5e Network
DALI
DALI
116 m
DALI
2 x 0.5 mm2
Single cable length
(= max. distance from PS)
DALI
DALI
DALI
Group or Scene control across
DALI networks on the same
gateway using C-Bus
Cable cross-section mm2
Group or Scene control on the
same Network using
DALI or C-Bus
DALI
DALI
DALI
DALI
DALI
DALI
DALI
Group #3
DALI
DALI
DALI
DALI
DALI
DALI
DALI
Group or Scene control
across DALI networks
and gateways using
C-Bus
DALI
DALI
Individual group control
always available via
DALI or C-Bus
DALI
DALI
DALIControl
Control
DALI
DALI
DALI
Group #4
DALI
DALI
DALI
DALI
DALI
DALI
DALI
DALI
Max 64 fittings
Max 64 fittings
DALI
DALI
Group or Scene control
across DALI networks
and gateways using
C-Bus
Max 64 fittings
Max 64 fittings
Note:
The DALI Ballasts are to be addressed with DALI
commissioning software connected directly to the DALI
Bus, not via the C-Bus commissioning software. This
software, and any associated hardware, is best provided
by the ballast manufacturer thus preventing warranty
disputes in the event of incorrect ballast operation
DALI
DALI
Group #5
DALI
DALI
Make the
most of
your energy
World energy consumption has risen
45% since 1980 and it is projected to be
70% higher by 2030. To limit energy cost
and its impact on the environment, we
must learn to adapt and manage energy
consumption, costs and pollutants.
Schneider Electric is committed to
reducing the energy cost and CO
emission of its customers.
2
Our products, solutions and services are
present at every link in the energy value
chain for the building, infrastructure,
industry and residential market to ensure
your comfort and performance, while
taking into account environmental issues.
This catalogue was printed at Blue Star
Print Group (NZ) Ltd, who are FSC Chain
of Custody certified, using FSC Chain of
Custody paper. FSC (Forest Stewardship
Council) is an international, not-forprofit membership-based organisation
that brings people together to find
solutions to problems created by bad
forestry practices and to reward good
management. The FSC Chain of Custody
is the highest and most trustworthy
international certification for paper and
timber products. This catalogue was
manufactured using mineral oil free ink
(produced with renewable resources,
unlike traditional mineral oil based inks).
The mill where the paper is manufactured
is ISO 14001, the paper is Elemental
Chlorine Free (ECF) and the pulp is Mixed
Sources FSC certified.
SCS COC 001217
71
71
Schneider Electric (NZ) Ltd.
14 Charann Place, Avondale, Auckland 1026
PO Box 15355, New Lynn, Waitakere 0640
Tel: +64 9 829 0490
Fax:+64 9 829 0491
www.schneider-electric.co.nz
132698
Customer Care: 0508 254 7725
Freefax: 0508 250 305
Email: sales@clipsal.co.nz
www.clipsal.co.nz
NZCLIPCBUSPOG1008
C-Bus Electrical Products are available through electrical wholesalers New Zealand wide.
C-Bus Electrical Products are designed to ISO 9001 and ISO 9002.
© 2009 Schneider Electric. As standards, specifications and designs change from time to time, always ask for confirmation of the information given in this publication.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising