HUB RADIATOR FULL

HUB RADIATOR FULL
HUB RADIATOR FULL
Patented high-efficiency heat pump to direct exchange coolant / water
to produce hot water and heating, for small users
Technical and construction features
HUB RADIATOR FULL is an integrated heating Open Cup system.
It consists of an external Moto-evaporating or recessed (Booster)
in heat pump that insures both the heating and the production of
hot water in a hygienically controlled mode through a separate
exchanger immersed directly into the internal tank.
HR FULL can also operate without a pump, to be installed on
classic radiators in a radius of about 1.5 meters from the tank.
HR FULL consists of three main elements: A - B - C
A Radiator technique water storage with direct exchangers
copper refrigerant / water and solar thermal or biomass
supplied as an option on request.
B Unit Moto-evaporating external (Booster) Low Power
energy, extremely quiet complete with a special
electronic controller that in the winter defrosting phase
uses the accumulated heat of 58 ° C in the buffer hot tank
to produce de-frost quickly and safely.
C Pump electronic inverters for high efficiency
distribution of conventional terminals (radiators) or plant
radiant floor (in this case can be requested as accessory a
thermostatic mixing valve) or with
FIJI fan (supplied as an accessory) installed on the wall,
which ensure temperature uniformity, constant filtration
air and low operating noise.
This new system makes it possible to avoid the installation of
intermediate exchangers, pumps of the primary circuit, glycol
antifreeze and securities required to avoid overheating and
excessive pressure of the technique water
C
A
B
B
Made in Italy
patent
RENEWABLE
ENERGY
TAXES
REDUCING
ENERGY
SAVING
HIGH
EFFICIENCY
60°
ECOLOGIC
GAS
PHOTOVOLTAIC
COMBINATION
DHW WITHOUT
LEGIONELLA
HEATING 60 °C
COMPACT
DIMENSION
€
Model
Code
HUB RADIATOR FULL 3.0/125
76112528
4.400,00
HUB RADIATOR FULL 3.0/300
76130028
4.800,00
HUB RADIATOR FULL 3.0/125 O.U.recessed
76112530
7.000,00
HUB RADIATOR FULL 3.0/300 O.U.recessed
76130030
7.400,00
HUB RADIATOR FULL 5.2/125
76112545
5.700,00
HUB RADIATOR FULL 5.2/300
76130045
6.100,00
HUB RADIATOR FULL 7.8/125
76112578
5.600,00
HUB RADIATOR FULL 7.8/300
76130078
6.000,00
HUB RADIATOR FULL 8.3/125
76112583
6.200,00
HUB RADIATOR FULL 8.3/300
76130083
6.600,00
HUB RADIATOR FULL 3.0+3.0/300 O.U.recessed
76330030
9.600,00
HUB RADIATOR FULL 7.8+7.8/300
76330078
7.900,00
Booster outdoor HR 3.0 heating (3.0 kW)
76010240
1.880,00
Booster outdoor HR 7.8 heating (7.8) kW
76010500
3.280,00
Circulator electronic inverter
additional max 3.3 m3/h
max head 6.2 m
power consumption min. 4 W - 45 W max
35006001
214,00
Mixing valve fixed point
for radiant systems at low temperature
75100003
200,00
Accessories HUB RADIATOR FULL
25
HUB RADIATOR FULL
Patented high-efficiency heat pump to direct exchange coolant / water
to produce hot water and heating, for small users
Accessories HUB RADIATOR FULL
Code
mod. 0,75 m2
mod. 1,50 m2
75100002
75101002
374,00
644,00
75100005
228,00
mod. Booster 3.0
mod. Booster 5.2-7.8-8.3
37081060
37081061
78,00
114,00
mod. 2000 W
mod. 3000 W
75050103
75060300
152,00
290,00
basic models:
mod. 125 l (H 242 - L 85 - P 25)
mod. 300 l (H 242 - L 150 - P 25)
75000125
75000300
330,00
450,00
models with closing panels:
mod. 125 l (H 242 - L 85 - P 25)
mod. 300 l (H 242 - L 150 - P 25)
75102125
75102300
436,00
598,00
mod. 125 l (H 242 - L 85 - P 25)
mod. 300 l (H 242 - L 150 - P 25)
75101125
75101300
460,00
620,00
mod. 125 l (H 222 - L 85 - P 28,5)
mod. 300 l (H 222 - L 150 - P 28,5)
75060200
75060201
570,00
1.040,00
75100007
120,00
75100020
384,00
26505565
300,00
Solar heat exchanger
heat or biomass
Control panel and remote control
wall or recessed
Anchor bracket for external
Booster including rubber
anti vibration
Option electrical resistance
increased single-phase
230 V degree of protection IP 65
recessed
template
galvanized
sheet with
or without
Closing panel
Sheet galvanized
recessed
internal template
galvanized sheet
complete
of Freestanding
panel recessed
wall fitting painted
MDF powder
AIR BOX
external cabinet
sheet prepainted
white RAL 7030
€
Wall thermostat to control
circulating pump with digital display
Support base with anti-vibration for external Booster
Additional capacitor
Booster for just hot
Booster Kit muted
75100001
184,00
Vibration damper kit for floor installation
75100021
62,00
Kit timer
35639900
110,00
26
HUB RADIATOR FULL
Patented high-efficiency heat pump to direct exchange coolant / water
to produce hot water and heating, for small users
HUB Connection diagram RADIATOR FULL
Legend:
1 Unit Moto-evaporating external (Booster) in heat pump
2 Solar thermal collector (accessory)
3 Supply hot water DHW
4 Exchanger quick DHW
5 Exchanger solar thermal or biomass (as accessory)
6 Exchanger refrigerant / water units outside Moto-evaporating
7 Electric heater from 1.5 kW (standard)
8 Radiator technique water storage Open Cup
9 Temperature sensor technical water
10 Remote control (accessory)
11 Anti-tip bracket
12 Drain tap
13 Drain “Overflow”
14 Example of connection with fan coil FIJI
15 Circulator system for radiant floor (as an accessory)
16 Pump for fan or radiator series
17 Fixed point mixing valve (accessory)
18 Taps refrigerant R410A for connecting external drive
19 Example of radiant floor heating EASY COMFORT
20 Solenoid filling
21 Level technical water
22 Taps 3/4”
23 Solar station lifting UNIT 2 (accessory)
24 Electrical control and monitoring
Installation example HUB RADIATOR FULL with accessories to be quoted separately
1)
2)
3)
4)
Form radiant copper EASY COMFORT wall, floor or ceiling
Heat exchanger solar thermal or biomass
Additional electric heater from 3.0 kW as an alternative to 1.5 kW as standard.
Additional circulation pump or pumping unit extra
2
3
4
1
27
HUB RADIATOR FULL
Patented high-efficiency heat pump to direct exchange coolant / water
to produce hot water and heating, for small users
Radiator size accumulator 125 liters
Radiator size accumulator 300 liters
Dimensions Booster external HR 5.2 - 8.3
Dimensions Booster recessed HR 3.0
140
Dimensions Booster external HR 5.2 - 8.3
Booster
L
H
P
kg
HR 3.0 external
700
552
256
33
HR 3.0 recessed
590
400
230
35
HR 5.2 external
950
690
360
55
HR 7.8 external
902
650
307
55
HR 8.3 external
925
872
368
76
Value in mm
28
HUB RADIATOR FULL
Patented high-efficiency heat pump to direct exchange coolant / water
to produce hot water and heating, for small users
Technical data table HUB RADIATOR FULL
DESCRIPTION
Thermal power air 7 °C / water 35 °C
COP
Thermal power air 2 °C / water 35 °C
COP
Thermal power air 7 °C / water 45 °C
COP
Thermal power air 2 °C / water 45 °C
COP
U.M.
HR 3.0
HR 5.2
HR 7.8
HR 8.3
HR 3.0 INC.
kW
3,11
5,51
8,12
9,12
3,12
W/W
4,12
4,11
4,10
4,10
3,95
kW
2,72
4,82
7,10
7,99
2,73
W/W
3,67
3,57
3,59
3,52
3,43
kW
2,97
5,25
7,75
8,68
2,98
W/W
3,16
3,07
3,07
3,01
2,95
kW
2,61
4,62
6,80
7,65
2,62
W/W
2,76
2,68
2,70
2,64
2,58
Water temperature max
°C
58
Fans
n.
1
Air temperature max
°C
45
min
°C
- 12
42
-7
Compressor type
Rotary
Refrigerant
R410A
230V/1/50Hz
Power supply
Current consumption in heating*
A
4,19
7,20
11,49
13,20
4,20
IP 24
Degree of protection
Water connection
”
3/4
Hydraulic connection for filling
”
1/2
Connecting domestic hot water
”
1/2
Connection refrigerant liquid
”
1/4
1/4
3/8
3/8
1/4
gas
”
3/8
1/2
5/8
5/8
1/2
Maximum length of refrigerant pipes
Sound pressure**
dB(A)
10
15
m
50
52
58
Water content accumulation HR 125
l
125
Water content accumulation HR 300
l
300
Pressure drop DHW circuit with flow rate of 10 l/m
Electric power system circulator
Max capacity circulating pump
Max head circulating pump
kPa
38
W
3 - 45
m3/h
3,3
m
57
52
6,2
Water quantity in single drawdown to 40 °C - HR 125 l
l
69
71
73
73
69
Water quantity in single drawdown to 40 °C - HR 300 l
l
130
130
132
133
130
Recovery time from 10 to 58 °C - HR 125 l
h
2,62
1,78
1,02
0,96
2,62
Recovery time from 10 to 58 °C - HR 300 l
h
5,21
3,51
2,06
1,98
5,18
Recovery time from 46 to 58 °C - HR 125 l
h
0,90
0,61
0,34
0,31
0,88
Recovery time from 46 to 58 °C - HR 300 l
h
1,81
1,23
0,72
0,65
1,81
Weight shipping unit 125
kg
87
Weight shipping unit 300
kg
122
Operating weight unit 125
kg
202
Operating weight unit 300
kg
422
Data referred to the following operating conditions
*Winter heating: external air temperature 7 ° C db - 6 ° C h.b., storage temperature 55 ° C
**Measured in free field conditions with a reference distance of one meter
29
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement