Ventilatoare centrifugale - Pliant ventilatoare centrifugale pentru seminee Vents KAM

Ventilatoare centrifugale - Pliant ventilatoare centrifugale pentru seminee Vents KAM
CALOR SRL
Str. Progresului nr. 30-40, sector 5, Bucuresti
tel: 021.411.44.44, fax: 021.411.36.14
www.calorserv.ro - www.calor.ro
CHIMNEY CENTRIFUGAL
FANS
IT’S NOT ONLY FIREPLACE THAT MAKES YOU FEEL WARM
A fireplace in the country house brings comfort and romance; it is a unique energy of country life. The warmth of fireplace recovers serenity of mind, calms and
harmonizes our thoughts in a philosophical manner. And, of course, it makes us feel warm.
Chimney fans designed for hot air distribution allow creating fully-featured air heating system based on a fireplace. Such system is the perfect solution for
heating of seasonal houses that serve as a secondary residence during winter time and provide fast and efficient hot air distribution from chimney to other premises.
VENTS KAM Series
Chimney fan is designed for house heating system management using heat of chimney or fireplace. It can be
also used as a base for backup heating source. Air capacity of the fan is up to 540 m3/h. The fans are compatible with
Ø 125, 140, 150 and 160 mm round ducts.
84
VENTS. Industrial and commercial ventilation | 11-2010
Chimney centrifugal fan
VENTS KAM
page
3
Air capacity – up to 540 m /h
Chimney centrifugal fan
VENTS KAM Eco
86
page
3
Air capacity – up to 470 m /h
Chimney centrifugal fan
VENTS KAM EcoDuo
Air capacity – up to 470 m3/h
VENTS. Industrial and commercial ventilation | 11-2010
86
page
86
85
CHIMNEY CENTRIFUGAL FANS
Series
VENTS КАМ
Chimney centrifugal fan for house
heating system management using
heat of chimney or fireplace. It can
be also used as a base for backup
heating source.
Applications
Chimney fans for hot air distribution allow creating
fully-featured air heating system based on a fireplace.
Such system is the perfect solution for heating of
seasonal houses that serve as a second residence
during winter time and provides fast and efficient hot
air distribution from chimney to other premises. Used
for air distribution with the air tempreature range
0°С to +150°С.
Design
The fan casing is made of galvanized steel and
equipped with heat- and sound insulation of fireresistant mineral wool. The casing is perforated
for the internal air circulation and motor cooling.
The temperature regulator is used for setting the
temperature level for the fan switching on and off.
Fan startup is effected within the range of 0 °С to
+90°С depending on the air temperature generated
inside the fireplace heat-exchanger.
Motor
The fans are supplied with single-phase motors
for operation in 230/50Hz power supply network.
Insulation Class F. The motors have built-in
overheating protection with automatic restart.
The motor is placed off-airflow and is equipped
with forward-curved impeller blades as well as ball
bearings for long service life. The fan models marked
KAM are equipped with asynchronous motors and
extra impeller for air blowing-off and cooling. The
fan motors models marked KAM Eco are equipped
with the external rotor. The fan motors models
marked KAM EcoDuo have two speeds and equipped
with the external rotor.
Speed control
Both smooth and step fan control is performed by
means of the thyristor or autotransformer (Models
KAM, KAM Eco). The fan speed is controlled within
the range of 0 to 100%. KAM EcoDuo fan speed is
controlled by means of the speed switch.
position with respect to the airflow direction indicated
with a pointer on the casing. Access for the fan
maintenance shall be reserved. Warm air feed ducts
shall be laid between the fan and each of the heated
rooms. Concealed air ducts system with forced warm
air circulation allows saving useful space in the house
and fits to the house design.
Accessories
FFK – removable G3 metal filter for boosted air
purification. The filter is connected to the fan casing
by lock-latches to provide easy removal of the filter
for cleaning.
KFK – removable metal mixing chamber with
incorporated thermal control damper and G3 filter
for boosted air purification. The mixing set is fixed
to the fan casing by means of lock-latches to ensure
easy removal for cleaning. Fan configuration with
KFK mixing chamber provides cool air supply into the
mixing chamber when the operating temperature
exceeds 90°С. Such configuration also allows hot air
withdrawal while the fan motor is not running.
GFK – gravitation backdraft damper to prevent air
back draft in the system. Such fan configuration that
includes KFK mixing set and GFK backdraft damper
ensures fan motor overheating protection based on
BY-PASS actuation, in particular when the motor is
not running due to no power supply. The fans with
such configuration enable backdraft damper shutting
and hot air distribution to other premises through
ventilation ducts when the motor is not running.
Mounting
The fireplace fans are designed for connection with
round air ducts. The fans can be mounted in any
Designation key:
Fan series
Duct connection
diameter
VENTS КАМ
125; 140; 150; 160
Motor
Modifications
Eco – with external rotor;
EcoDuo – two-speed with
external rotor
_ – is equipped with temperature regulator
by default;
T1– without temperature regulator
Accessories
page 305
86
page 305
Accessories
MKF
FFK
KFK
GFK
ТS-1-90
WWW.VENTILATION-SYSTEM.COM
1
KAM, KAM Eco and KAM EcoDuo fans operation principle.
When the temperature in the fireplace hood reaches
the set value the fan turns automatically on and
distributes hot air from the fire hood place to other
premises. It turns off when the temperature falls down
below the set value.
KAM, KAM Eco,
KAM EcoDuo
Operation principle of KAM fan with FFK box filter
+
FAN SERIES VENTS КАМ
2
=
FFK
KAM
When the temperature in the fireplace hood reaches the set value the fan turns automatically on and distributes the hot air purified by FFK
filter from the fire hood to other rooms. It turns off when the temperaure falls down below the set value.
Operation principle of KAM fan with KFK damper
3
+
When the temperature in the fireplace hood reaches the set value the fan
turns automatically on and distributes hot air from the fire hood place to
other rooms. It turns off when the temperature falls below the set value.
The fan with KFK mixing set provides additional hot air supply of hot air to
the mixing chamber when the temperature of distributed air exceeds 90°С
and as well as the withdrawal of the hot air when the motor is not running.
=
КАМ
KFK
Operation principle of KAM fan with KFK damper and GFK backdraft damper with BY-PASS system
4
+
КАМ
+
KFK
=
GFK
When the temperature in the fireplace hood reaches the set value the fan
turns automatically on and distributes hot air from the fire hood place to
other premises. It turns off when the temperature falls below the set value.
BY-PASS system ensures overheating protection, i.e. the fan does not
operate at no power supply. It closes the damper and boosts hot air through
the opened gap to other premises. BY-PASS regulates the temperature by
mixing chamber damper opening providing the cold air supply if the air
supplied to the fan is too hot.
VENTS. Industrial and commercial ventilation | 11-2010
87
CHIMNEY CENTRIFUGAL FANS
Installation and operation of KAM fans, KAM fans with
FFK filter in the chimney system.
Installation and operation of KAM fans with KFK damper, KAM fans with KFK and
GFK dampers with BY-PASS system in the chimney system
Fan overall dimensions:
Type
КАМ 125
КАМ 140
КАМ 150
КАМ 160
КАМ 125 Eco
КАМ 125 EcoDuo
КАМ 140 Eco
КАМ 140 EcoDuo
КАМ 150 Eco
КАМ 150 EcoDuo
КАМ 160 Eco
КАМ 160 EcoDuo
Dimensions [mm]
B
H
H1
L
P
Mass
[kg]
124
139
149
159
245
285
285
285
350
350
350
350
300
300
300
300
260
300
300
300
50
50
50
50
4,5
5,7
5,7
5,7
124
245
320
270
260
50
5,6
139
285
320
270
300
50
6,8
149
285
320
270
300
50
6,8
159
285
320
270
300
50
6,8
D
Overall dimensions of fans with additional equipment:
Fan type
Dimensions [mm]
D
B
H
H1
L
P
Mass
[kg]
КАМ 125
КАМ 140
КАМ 150
КАМ 160
КАМ 125 Eco
КАМ 125 EcoDuo
КАМ 140 Eco
КАМ 140 EcoDuo
КАМ 150 Eco
КАМ 150 EcoDuo
FFK
FFK
FFK
FFK
124
139
149
159
245
285
285
285
530
540
540
540
480
490
490
490
260
300
300
300
50
50
50
50
6,7
8,7
8,7
8,7
FFK
124
245
500
450
260
50
7,8
FFK
139
285
510
460
300
50
9,8
FFK
149
285
510
460
300
50
9,8
КАМ 160 Eco
КАМ 160 EcoDuo
FFK
159
285
510
460
300
50
9,8
Type
КАМ 125
КАМ 140
КАМ 150
КАМ 160
КАМ 125 Eco
КАМ 125 EcoDuo
КАМ 140 Eco
КАМ 140 EcoDuo
КАМ 150 Eco
КАМ 150 EcoDuo
КАМ 160 Eco
КАМ 160 EcoDuo
88
Additional
equipment
Additional
equipment
Dimensions [mm]
D
B
H
H1
L
P
Mass
[kg]
KFK / KFK+GFK
KFK / KFK+GFK
KFK / KFK+GFK
KFK / KFK+GFK
124
139
149
159
245
285
285
285
610
650
650
650
560
600
600
600
260
300
300
300
50
50
50
50
8,3
9,7
9,7
9,7
KFK / KFK+GFK
124
245
580
530
260
50
9,4
KFK / KFK+GFK
139
285
620
570
300
50
10,8
KFK / KFK+GFK
149
285
620
570
300
50
10,8
KFK / KFK+GFK
159
285
620
570
300
50
10,8
VENTS. Industrial and commercial ventilation | 11-2010
WWW.VENTILATION-SYSTEM.COM
Voltage [V / 50 Hz]
Power [W]
Current [A]
Maximum air flow [m3/h]
RPM [min-1]
Noise level at 3 m [dBA]
Maximum operating temperature [оC]
Protection rating
Technical data:
Voltage [V / 50 Hz]
Power [W]
Current [A]
Maximum air flow [m3/h]
RPM [min-1]
Noise level at 3 m [dBA]
Maximum operating temperature [оC]
Protection rating
Technical data:
Speed
Voltage [V / 50 Hz]
Power [W]
Current [A]
Maximum air flow [m3/h]
RPM [min-1]
Noise level at 3 m [dBA]
Maximum operating temperature [оC]
Protection rating
External temperature
regulator ТS-1-90
for chimney fans VENTS KAM T1,
VENTS KAM Eco T1, VENTS KAM
EcoDuo T1
KAM 125
KAM 140
KAM 150
KAM 160
1~ 230
108
0,81
400
1300
42
150
IP X2
1~ 230
110
0,82
480
1290
42
150
IP X2
1~ 230
115
0,84
520
1280
42
150
IP X2
1~ 230
116
0,86
540
1270
42
150
IP X2
КАМ 125 Eco
КАМ 140 Eco
КАМ 150 Eco
КАМ 160 Eco
1~ 230
32
0,14
350
1335
37
150
IP X2
1~ 230
41
0,18
420
1250
38
150
IP X2
1~ 230
43
0,19
450
1165
39
150
IP X2
1~ 230
44
0,19
470
1110
39
150
IP X2
КАМ 125
EcoDuo
min.
max.
1~ 230
26
32
0.12
0.14
265
350
1210
1335
29
37
150
IP X2
КАМ 140
EcoDuo
min.
max.
1~ 230
32
41
0.14
0.18
340
420
1180
1250
31
38
150
IP X2
КАМ 150
EcoDuo
min.
max.
1~ 230
34
43
0.15
0.19
360
450
1075
1165
31
39
150
IP X2
КАМ 160
EcoDuo
min.
max.
1~ 230
35
44
0.15
0.19
375
470
1040
1110
32
39
150
IP X2
J
Applications
The temperature regulator is designed for chimney
fan control and applied for hot air distribution from
chimney to the premises.
FAN SERIES VENTS КАМ
Technical data:
the fan operation and switches the chimney fan on
or off depending on the set temperature increase or
decrease.
J
J
Design and control
The temperature regulator casing is made of metal
and equipped with the temperature control knob.
The casing is connected with the temperature probe
by means of a capillary tube of 1 m length. The
temperature level is followed by the temperature
probe which is installed directly inside the fireplace
heat-exchanger. The temperature regulator controls
Mounting
The temperature regulator is mounted in the
concealed or external mounting box. The temperature
probe is installed inside the fireplace heat-exchanger.
The temperature regulator shall be installed away
from the source of air heating. The wiring diagram
for the controller is no. 31, 32 (refer the section
«Wiring Diagams»).
Technical data:
ТS-1-90
Temperature
probe
Voltage [V/50/60 Hz]
Maximum load current [A]
Maximum fan power [W]
Range of controllable temperatures [°С]
Overall dimensions of the thermostat casing, [mm]
Capillary tube length [mm]
Temperature probe
Maximum ambient temperarture for the casing [°С]
Maximum temperature for the temperature probe and capillary tube [°С]
Protection rating
VENTS. Industrial and commercial ventilation | 11-2010
1~ 230
2,2 А
500
0…+90
55 х 56 х 56
1000
6,5 х 95 mm
+80
+150° С
ІР40
89
CHIMNEY CENTRIFUGAL FANS
P [Pa]
VENTS КАМ Eco
Pressure,
Pressure,
P [Pa]
VENTS КАМ
Air capacity, [m3/h]
Air capacity, [m3/h]
P [Pa]
VENTS КАМ Eco
Pressure,
Pressure,
P [Pa]
VENTS КАМ
Air capacity, [m3/h]
Air capacity, [m3/h]
P [Pa]
VENTS КАМ Eco
Pressure,
Pressure,
P [Pa]
VENTS КАМ
Air capacity, [m3/h]
Air capacity, [m3/h]
P [Pa]
VENTS КАМ Eco
Pressure,
Pressure,
P [Pa]
VENTS КАМ
Air capacity, [m3/h]
90
VENTS. Industrial and commercial ventilation | 11-2010
Air capacity, [m3/h]
WWW.VENTILATION-SYSTEM.COM
ELECTRICAL ACCESSORIES COMPATIBILITY
КАМ 125 Eco
КАМ 140 Eco
КАМ 150 Eco
КАМ 160 Eco
КАМ 160 EcoDuo
КАМ 160
КАМ 150 EcoDuo
КАМ 150
КАМ 140 EcoDuo
КАМ 140
КАМ 125 EcoDuo
КАМ 125
Pressure,
P [Pa]
VENTS КАМ EcoDuo
RS-1-300
z
z
z
z
z
z
z
z
RS-1-400
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
Air capacity, [m3/h]
Pressure,
P [Pa]
VENTS КАМ EcoDuo
z
RS-1 N (V)
z
RS-1,5 N (V)
z
RS-2 N (V)
z
RS-2,5 N (V)
RS-0,5-PS
z
RS-1,5-PS
z
RS-2,5-PS
z
RS-4,0-PS
z
RS-1,5-Т
z
RS-3,0-Т
z
RS-5,0-Т
RS-10,0-Т
z
RS-1,5-ТА
z
RS-3,0-ТА
z
RS-5,0-ТА
RS-10,0-ТА
Transformer speed controllers
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
RSA5D-3,5-Т
RSA5D-5-М
RSA5D-8-М
RSA5D-10-М
RSA5D-12-М
Frequency speed controllers
VFED-200-ТА
VFED-400-ТА
VFED-750-ТА
VFED-1100-ТА
VFED-1500-ТА
Temperature regulators
RTS-1-400
RTSD-1-400
z
z
z
z
z
z
z
z
z
z
z
z
P [Pa]
Pressure,
P [Pa]
z
z
RT-10
Pressure,
RSA5Е-2-М
RSA5Е-3-М
RSA5Е-4-М
RSA5Е-12-М
RSA5Е-1,5-Т
RSA5Е-3,5-Т
RSA5Е-5,0-Т
RSA5Е-8,0-Т
RSA5Е-10,0-Т
RSA5D-1,5-Т
VENTS КАМ EcoDuo
VENTS КАМ EcoDuo
RSA5Е-2-P
Air capacity, [m3/h]
Air capacity, [m3/h]
Multi-speed fan switches
P2-5,0
P3-5,0
P5-5,0
P2-1-300
P3-1-300
EC-motors controllers
R-1/010
z
z
z
z
z
z
z
z
z
z
z
z
z
z
FAN SERIES VENTS КАМ
Thyristor speed controllers
z
z
Sensors
Т-1,5 N
ТН-1,5 N
ТF-1,5 N
ТР-1,5 N
Air capacity, [m3/h]
z
recommended
z
suitable
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
z
CALOR SRL
Str. Progresului nr. 30-40, sector 5, Bucuresti
tel: 021.411.44.44, fax: 021.411.36.14
www.calorserv.ro - www.calor.ro
VENTS. Industrial and commercial ventilation | 11-2010
91
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement