Honeywell LYNX is a comprehensive security system that provides protection against burglary, fire, and other emergencies. With its advanced features and user-friendly interface, Honeywell LYNX offers various ways to keep your home and family safe.
Features:
- Burglary Detection: The system can be armed in Stay, Away, and Instant modes, ensuring protection even when you're home.
- Fire and Carbon Monoxide Detection: Honeywell LYNX monitors for smoke and carbon monoxide, providing early warning in case of a fire or gas leak.
- Medical and Panic Alarms: The system allows for manual activation of fire, police, and medical alarms using the keypad.
advertisement
Testing the System
Using the Test mode allows each detection point to be checked for proper operation. Testing should be conducted weekly to
ensure proper operation.
• The keypad sounds a single beep about every 30 seconds as a reminder that the system is in the Test mode.
• Alarm messages are not sent to your Central Station during testing.
If a problem is experienced with any detection point (no confirming sounds, no display), call for service immediately.
1. Disarm the system and close all protected windows, doors, etc.
The ready indicator LED should be lit if all zones are intact.
2. At the Master Menu Screen Select the “Test” icon followed by the
“Walk Test” icon.
3. Listen. The sounder should beep one time and “Walk Test-Off to
Quit” should be displayed. The control sounds a single beep every
30 seconds while the test is in progress. If the sounder does
not sound, CALL FOR SERVICE.
4. Fault zones. Open each protected door and window in turn and listen for three beeps from the keypad followed by the zone’s voice descriptor. Each faulted detection point should appear on the display. The display clears when the door or window is closed.
5. Walk in front of any interior motion detectors (if used) and listen for three beeps. Each detector should appear on the display when it is activated. The display clears when no motion is detected. Note that if wireless motion detectors are used, there is a 3-minute delay between activations to conserve battery life.
6. Test all smoke detectors, following the manufacturer's instructions.
7. When all detection points have been checked and are intact
(closed), there should be no zone numbers displayed.
8. Exit test mode by entering an Off Sequence.
System Displays
A "beeping" at the control, indicates a trouble condition in the system and requires your attention. Determine if the zone(s) displayed are intact and make them so if they are not. If the display persists, CALL FOR SERVICE.
Press any key to silence the beeping for these conditions.
The following icons will be displayed on the Home screen along with zone status information (if applicable) indicating system status:
AC Loss Door Open
Alarm
(intrusion)
Window
Open
Armed
Away
Exit Active
Armed
Stay
Fire OR
Heat
Sensor
Flood Battery
Low
Check
Zones
Glass Break
CO Alarm Medical
Alarm
Disarmed
Not Ready to Arm
Disarmed
Motion
Temperature
Ready to
Arm
90 RF Jam Cover
Tamper
Reporte r Failure
72
Automation
(Z-Wave
Failure)
See the full User Guide for additional details.
Garage
Door Fault
WiFi source present
No WiFi source
94 Phone
Line Cut
103 Comm.
Trouble
Zone Status
The following icons will be displayed on the Zone Status screen along with zone status information when a zone has been faulted, bypassed or is in alarm:
Display Definition Display
Alarm
Fault (Yellow)
Definition
Ready
Bypass
Trouble (red)
Setting the Date and Time
NOTE: The system must be disarmed before date/time can be set.
You can set the time and date by doing the following:
1.
+
2.
Date Time
(Master Code)
• Use the “” or “” to select the correct month/year.
• Select the correct date. Use the “” to advance.
• Select “Clear” then enter the correct time
• Select AM/PM then select “Save” or use the “” to advance.
• Select correct Time Zone
• Enable/disable Day Light Savings Time.
• If required select Day Light Saving Start/End
Month/Week.
• Select “Save”
Manually Controlling Home Automation Devices
Your system may be equipped Home Automation (Z-Wave) Devices.
These devices are normally controlled using programmed scenes but can also be activated/controlled manually. To control home automation devices manually, perform the following:
Mode
Press these Keys or
Icons…
What happens
Activating
Z-Wave
Devices
72
Automation
+
OR
68
OR
OR
• You may be able to override automatically controlled Zwave devices using the
Automation commands.
• Some devices can be manually activated or deactivated using the
Automation commands.
• See your Installer for details on controlling Z-Wave devices.
Note: For additional information regarding your system’s Home
Automation features refer to the full version User Guide and to the Home Automation Guide.
Servicing Information
Your local Honeywell dealer is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable. Your local Honeywell dealer is:
Name:
Address:
Phone:
Ê800-12741QGÊ
800-12741QG 9/12 Rev A Part 1
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2012 Honeywell International Inc.
www.honeywell.com/security
LYNX TOUCH SECURITY SYSTEM
Quick Guide to User Functions
Full User Guide Available Online: This Quick Guide describes the most frequently used features and functions of your system. For full details of all user functions, please see the system’s User Guide located online at: http://www.security.honeywell.com/hsc/products (see LYNX Touch
Security System User Guide P/N 800-10615 or higher). The full version User Guide is also available from your installer upon request.
Congratulations on your ownership of a Honeywell Security System. This system provides:
• Three forms of detection: burglary, fire and emergency (see your installer for which forms of detection are installed)
• At least one keypad which provides control of system and displays system status
• Various sensors for perimeter and interior burglary detection
• Optional smoke or combustion detectors designed to provide early warning in case of fire.
Your system may also be programmed to automatically send alarm and status messages to a Central Monitoring Station.
System Basics
The following is a list of some of the most common features and functions of your system:
• Several modes of burglary detection: Stay, Away, Instant.
• Bypass feature lets you bypass selected zones while leaving the rest of the system armed.
• Chime mode alerts you to the opening of protected doors and windows while the system is disarmed.
• Fire and carbon monoxide detection are always active (if installed) and an alarm sounds if a fire or carbon monoxide condition is detected.
• Panic keys (if programmed) let you manually initiate fire, police and medical alarms using the keypad.
• 4-digit security codes are used in conjunction with keypad commands to perform system functions.
• Each user (up to 14) can be assigned a different security code.
• The system sensing devices have been assigned to various
“zones,” which are specific areas of detection (e.g., front door, kitchen window, etc.).
• Zone numbers (points of detection) are displayed at the keypad when an alarm or trouble condition occurs.
• Message Center allows recording and play-back of brief voice messages.
• Speaker Phone allows the control to be used for hands free telephone conversation. See the full User Guide for details.
• Two-way Voice allows the Central Station to listen, talk or conduct a two-way conversation with in individuals at the premises. See the full User Guide for details.
• Follow me reminder announcements allow the panel to dial a number and deliver system status messages. See the full User
Guide for details.
• A Scheduling feature can be programmed to automatically perform certain functions (e.g., arm the system) at a predetermined time each day. See the full User Guide for details.
Entry/Exit Delays
• Entry Delays give you time to disarm the system when you enter through the designated entrance door.
• You must disarm the system before the entry delay period ends, or an alarm will occur (keypad beeps during the entry delay period, reminding you to disarm the system).
• Exit delay gives you time after arming the system to leave through the designated exit door(s) without setting off an alarm.
If programmed, a slow beeping will sound during the exit delay period until the last 10 seconds, which then changes to fast beeping (alerting you to the end of exit delay). If you cannot leave within this delay time period, you should stop, disarm the system, and start over to avoid a false alarm.
• See your installer for your delay times. See the full User Guide for details on Exit Error alarms.
Notes on Burglary Detection
• The system must be armed before the burglary detection can sense intrusions.
• To arm your system, select the desired arming key or icon and enter your security code.
• To arm your system, if the Quick Arm feature is enabled select the desired arming key or icon followed by the Quick Arm icon.
You do not need to enter your security code.
• To disarm the system, select the Off key or the Disarm icon and enter your security code.
• When an alarm occurs, the control sounds and displays the zone(s) causing the alarm. An external sounder may also sound, if installed.
• If your system is connected to a Central Monitoring Station, an alarm message is also sent (delayed 30 seconds by default to reduce false alarms).
• To stop the alarm sounding, simply disarm the system.
• Memory of Alarm: When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm. Clear the Memory of
Alarm display by entering another “off” sequence.
IMPORTANT
If you return to the premises and the burglary sounder is on, or the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE
POLICE from a nearby safe location.
Notes on Fire and CO Detection
• Your fire alarm system (if installed) is on 24 hours a day, for continuous detection. In the event of an emergency, the smoke and heat detectors sound their alarms, triggering a loud, interrupted pulsed sound from the control and any external sounder(s) (if installed).
• You can silence the alarm at any time by pressing the Off key
(the security code is not needed to silence fire alarms).
• Carbon monoxide (CO) detectors, if installed, provide continuous detection. If a high level of carbon monoxide is detected, an interrupted pulsed alarm sound occurs at the control and the detector(s). Immediately move to a spot where fresh air is available, preferably outdoors. From a safe area, call your security service provider for further instructions. To silence the control sounding, press the Off key. To silence the detector, see its instructions.
LYNX Touch L5100
Checking Open Zones or System Status
Checking Zones: Before arming your system, all protected doors, windows and other detection zones must be closed or bypassed; otherwise the keypad displays “Not Ready to
Arm.”
Mode Press these icons… What happens
Check
Zones
Bypass
Zones
Zones
Zones
• Displays all faulted zones.
Check
System
Status
• Displays system status.
Arming the System
Before arming, close all perimeter doors and windows and make sure the “Ready to Arm” message is displayed. Select the specified icon or key and enter the 4-digit Security Code. The system will beep three times to confirm the arming.
After arming, leave the premises through an entry/exit door during the exit delay period and be sure the door is reclosed to avoid causing an alarm.
Mode
System
Press these keys or icons…
When to use an arming mode and what happens
Stay
Arm Stay
• Used when you want to arm the system with persons staying inside (or if you have pets that are moving throughout the premises).
• Arms perimeter zones; interior zones left disarmed.
• An alarm sounds if any protected window or nonentry/exit door is opened.
Instant
Stay
Away
Instant tab +
OR
Arm Stay
Arm Away
• Used when staying inside and you do not expect anyone to use an entry/exit door.
• Same as Stay mode, except entry delay is off.
• An alarm sounds same as Stay mode, and sounds upon opening entry/exit doors.
• Used when nobody is staying inside (including pets).
• Arms the entire system (interior and perimeter).
• An alarm sounds if a protected window or any door is opened, or if any movement is detected inside.
Quick
Arming
Arm Stay
OR
Arm Away
• If programmed, you can press the Quick Arm button in place of your security code when arming the system
Disarming the System and Silencing Alarms
The “Off” key or “Disarm” icon is used to disarm the system, silence alarm and trouble sounds, and clear memory of alarm displays. Select the specified icon or key and enter the
4-digit Security Code.
Mode
Press these keys or icons…
What happens
Disarm and
Silence
Alarms
OR
Disarm
• System is disarmed and alarm sounding is silenced.
• To clear the memory of alarm display (if present), enter a second Off Sequence.
• To Silence a Fire Alarm or Carbon Monoxide Alarm
Simply press the “Off” key or “Disarm icon (no code needed)
Bypassing Zones
Select the “Zones” icon key when you want to arm your system with one or more zones intentionally unprotected. The system must be disarmed first.
Mode Press this icon… What happens
• When finished, the zones screen will be displayed along with zone status.
• Arm the system as usual. When armed, the arming message is displayed with “Bypass.”
• Bypassed zones are unprotected and will not cause an alarm if violated.
• The system will not allow fire zones to be bypassed.
• Zones are automatically unbypassed when the system is disarmed.
• To display bypassed zones prior to arming, select the “Zones icon.
Panic Keys
Your system may have been programmed to use special keys/icons to manually activate emergency (panic) functions as follows:
To activate a Panic Function:
Press and hold down the Panic key for at least 2 seconds, then select the
Desired Panic function icon as indicated below:
Panic Function
Police Alarm
Medical Alarm
Icon
Police
Sends this Signal*
Silent Alarm OR
Audible Alarm
Auxiliary Alarm
With this Sounding…
No audible alarm; displays, “Not Ready to
Arm,” indicating that a silent alarm has been initiated. OR
A loud, steady alarm at panel at external siren (if installed); displays “Alarm 99
Police”
Steady alarm sound at panel, but not at external siren (if installed); displays “Alarm
96 Medical”
Medical
Fire Alarm
Fire
Fire Alarm
Temporal (pulsing) sound at panel and external siren (if installed); displays “Fire
Alarm 95”
* All panic functions send signals to the Central Monitoring Station, if connected.
9
8
7 6 5
1
2
3
4
5100-500-002-V0
Index Item Description
1 Display
Window
2 Ready
(Green) LED
Indicator
3 Home key
Color Liquid Crystal Display (LCD) Touch screen. Displays system status icons, time, system status information, user menus and the virtual keypad.
ON = System is ready to be armed
OFF = System is armed
Blinking = System is disarmed, and not ready to be armed (a fault exists)
Blinking alternately with Ready LED = Speaker phone mode is active
Used to exit from a screen or return to the home screen.
4 Speaker Source of audible internal warning and confirmation sounds, status announcements, as well as alarms (Refer to the full User Guide for details).
5 Off key
(Disarm) touch screen. Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected.
6 Microphone Used to record personal messages via the Message Center, and for twoway voice and speaker phone operation.
7 Panic key When depressed for 4 seconds, the virtual panic icons are displayed on the touch screen.
8 Away key
9 Armed
(Red) LED
Indicator
Completely arms both perimeter and interior burglary protection for backup protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc.
Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires.
ON = System is armed (Stay or Away)
OFF = System is disarmed
Blinking = System armed, and an alarm or fault has occurred.
Blinking alternately with Ready LED = Speaker phone mode is active
System Settings
Your system settings including volume level (message playback, system announcements, and status beeps) and display brightness and contrast can be adjusted if desired.
Additionally, you can turn On/Off the Chime, Telephone Ringer and/or System Voice
Announcements. A cleaning icon is also available via the system settings.
Note: To enable or disable the Chime mode the system must be disarmed.
Mode
Press these Keys or
Icons…
What happens
Voice
Mode
Settings
+ Voice
• Enables or disables the Voice announcement of system status.
Chime
Mode
Settings
+ Chime
• Alerts you to the opening of a perimeter door or window while the system is disarmed.
• Open (faulted) zone information is displayed.
• Three tones sound at the keypad whenever a perimeter door or window is opened (faulted interior zones do not produce a tone).
Ringer
Mode
+ Ringer
• Enables or disables the Telephone Ringer.
Settings
Adjust
Brightness,
Contrast or
Volume Settings
+
Brightness
OR
Contrast
OR
Volume
• Slide the button to Adjust the display brightness, contrast or system volume.
Clean the
Touchscreen
Settings
Record a Message
+
Clean
• The touchscreen becomes inactive for 15 seconds then returns to the settings screen and becomes active.
Your system can record brief single or multiple messages. The total available recording time is 184 seconds.
Function
Press this
Icon…
Perform the following…
Record a
Message
Play OR
Delete
Messages
Message
Message
• Select “Add New” to Record a Message.
• Select “Record”.
• Select “Stop” when recording is complete. Then select “”.
• The recorded message list is displayed. Select the “” to return to the Security Home Screen.
• Select the Message that you wish to play or delete.
• Select “Play” or “Delete All” as applicable.
• Select the “” to return to the Security Home Screen.
Security Codes
Your installer assigned a master code that is used to perform all system functions.
In addition, security codes can be assigned for up to 14 users. Only the Master User can assign security codes to users.
Tools
To Add/Edit/Delete User Codes:
Select the “Tools” icon on the second page of the Security Home Screen, then follow the steps below:
Function
Press this
Icon…
Perform the following…
Change
Master
User Code
Add
Security
Code
Users
Users
• Select “Master”, then select “Edit”
• Select “User Code”
• Enter a new 4-digit Master Code.
• Select “Done”, then select “Save”.
• Select “Add new”
• Select “Name”, then select “Clear”
• Type a User Name, then select “Done”
• Select “User Code”
• Enter a new 4-digit User Code.
• Select “Done”, then select “Save”.
Edit/Delete
Security
Code
Users
• Select “Name”, then select “Edit” or “Delete”
• Type “Name” or “User Code”
• Enter a new User Name OR 4-digit User Code.
• Select “Done”, then select “Save”.