Installation Instructions 30", 36" and 48" Professional Vent Hood

Installation Instructions 30", 36" and 48" Professional Vent Hood
Installation
Instructions
30", 36" and 48"
Professional Vent Hood
ZV48SSJSS, ZV36SSJSS, ZV30SSJSS,
ZV48TSJSS, ZV36TSJSS, and ZV30TSJSS
31-11016-1
09-15 GE
monogram.com
Printed in Italy
Safety Information
“If you have questions, call 800.GE.CARES RUYLVLWRXUZHEVLWHDW*($SSOLDQFHVFRPµ
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT³6DYHWKHVHLQVWUXFWLRQVIRUORFDO
LQVSHFWRU·VXVH
•
IMPORTANT³2EVHUYHDOOJRYHUQLQJFRGHVDQG
ordinances.
• Note to Installer³%HVXUHWROHDYHWKHVHLQVWUXFWLRQV
ZLWKWKH&RQVXPHU
• Note to Consumer³.HHSWKHVHLQVWUXFWLRQVZLWK\RXU
2ZQHU·V0DQXDOIRUIXWXUHUHIHUHQFH
• Skill level³,QVWDOODWLRQRIWKLVDSSOLDQFHUHTXLUHVD
TXDOLILHGLQVWDOOHURUHOHFWULFLDQ
‡3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRWFRYHUHG
XQGHUWKHZDUUDQW\6HH2ZQHU·V0DQXDOIRUZDUUDQW\
LQIRUPDWLRQ
WARNING:
,PSURSHUJURXQGLQJFDQUHVXOWLQDULVNRIHOHFWULFVKRFN
WARNING:
TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING.
• Installation work and electrical wiring must be
GRQHE\DTXDOL¿HGSHUVRQVLQDFFRUGDQFHZLWK
DOODSSOLFDEOHFRGHVDQGVWDQGDUGVLQFOXGLQJ¿UH
rated construction.
• 6XȻFLHQWDLULVQHHGHGIRUSURSHUFRPEXVWLRQDQG
H[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RI
IXHOEXUQLQJHTXLSPHQWWRSUHYHQWEDFNGUDIWLQJ
)ROORZWKHKHDWLQJHTXLSPHQWPDQXIDFWXUHU·V
JXLGHOLQHVDQGVDIHW\VWDQGDUGVVXFKDVWKRVH
SXEOLVKHGE\WKH1DWLRQDO)LUH3URWHFWLRQ
$VVRFLDWLRQ1)3$DQGWKH$PHULFDQ6RFLHW\
IRU+HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ
(QJLQHHUV$6+5$(DQGWKHORFDOFRGHDXWKRULWLHV
• :KHQFXWWLQJRUGULOOLQJLQWRZDOORUFHLOLQJGRQRW
GDPDJHHOHFWULFDOZLULQJDQGRWKHUKLGGHQXWLOLWLHV
• 'XFWHGIDQVPXVWDOZD\VEHYHQWHGWRWKH
outdoors.
CAUTION:
&RQVXOWDTXDOLILHGHOHFWULFLDQLIWKHJURXQGLQJLQVWUXFWLRQV
DUHQRWFRPSOHWHO\XQGHUVWRRGRULIGRXEWH[LVWDVWR
ZKHWKHUWKHDSSOLDQFHLVSURSHUO\JURXQGHG
)RU0RQRJUDPORFDOVHUYLFHLQ\RXUDUHD
7RUHGXFHWKHULVNRI¿UHDQG
WRSURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWGRRUV
'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVRU
FHLOLQJVRULQWRDWWLFVFUDZOVSDFHVRUJDUDJHV
)RU0RQRJUDP6HUYLFHLQ&DQDGDFDOO
TO REDUCE THE RISK OF
FIRE, USE ONLY METAL DUCTWORK.
)RU0RQRJUDP3DUWVDQG$FFHVVRULHVFDOO
WARNING:
,I\RXUHFHLYHGDGDPDJHGYHQWKRRG\RXVKRXOGFRQWDFW
your dealer.
CAUTION:
'XHWRWKHZHLJKWDQGVL]HRIWKHVHYHQWKRRGVDQG
WRUHGXFHWKHULVNRISHUVRQDOLQMXU\RUGDPDJHWRWKH
SURGXFWTWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
WARNING:
7RUHGXFHWKHULVNRIILUHRUHOHFWULFDOVKRFNGRQRW
XVHWKLVUDQJHKRRGZLWKDQ\H[WHUQDOVROLGVWDWHVSHHG
FRQWUROGHYLFH$Q\VXFKDOWHUDWLRQIURPRULJLQDOIDFWRU\
ZLULQJFRXOGUHVXOWLQGDPDJHWRWKHXQLWDQGRUFUHDWH
DQHOHFWULFDOVDIHW\KD]DUG
2
31-11016-1
Installation Instructions
CONTENTS
Product Dimensions .............................................................................. 3
3DUWV3URYLGHG .......................................................................................... 4
+DUGZDUH3DFNDJH ................................................................................ 4
7RROVDQG0DWHULDOV5HTXLUHG ........................................................... 5
,QVWDOODWLRQ&OHDUDQFHV ........................................................................ 6
2SWLRQDO'XFW&RYHU$FFHVVRULHV .................................................... 6
'HWHUPLQH,QVWDOODWLRQ+HLJKW'XFW&RYHU$FFHVVRULHV ......7
$GYDQFH3ODQQLQJ .................................................................................. 8
3RZHU6XSSO\ ............................................................................................ 8
6WHS'HWHUPLQH'XFWZRUNDQG:LULQJ/RFDWLRQV ...............9
6WHS$,QVWDOO+RRG2QWR:DOO.................................................... 12
6WHS%,QVWDOO+RRG7R6RȻW2U%HQHDWK&DELQHWV ........... 11
6WHS&RQQHFW'XFWZRUN ............................................................... 12
6WHS&RQQHFW(OHFWULFDO ................................................................ 12
6WHS,QVWDOO'XFW&RYHUV............................................................... 12
6WHS,QVWDOO)LOWHUV............................................................................ 13
6WHS,QVWDOO,PSOHPHQW5RGV ...................................................... 13
PRODUCT DIMENSIONS
47-15/16"
12"
18"
18"
47-15/16"
25"
0RGHO=96:LWK6WUDLJKW6LGHV
25"
47-15/16"
0RGHO=97:LWK7DSHUHG6LGHV
28"
12"
35-15/16"
12"
18"
18"
25"
25"
35-15/16"
0RGHO=96:LWK6WUDLJKW6LGHV
35-15/16"
0RGHO=97:LWK7DSHUHG6LGHV
29-15/16"
12"
12"
22"
18"
18"
25"
29-15/16"
0RGHO=96:LWK6WUDLJKW6LGHV
31-11016-1
40"
12"
25"
29-15/16"
0RGHO=97:LWK7DSHUHG6LGHV
3
Installation Preparation
PARTS PROVIDED
/RFDWHWKHSDUWVSDFNHGZLWKWKHKRRG
:RRG6XSSRUW
ZLWK2ULJLQDO6FUHZV
2 Knobs
2 Stainless Steel Grease Filters
¿OWHUVZLWKPRGHOV
+HDW/DPS
ZLWKPRGHOV
,PSOHPHQW5RGV$OOHQ6FUHZV
DQG6WDQGRȺV
2 Grease Filter Trays
VXSSRUWVZLWKPRGHOV
0RQRJUDP/RJR
1DPHSODWH
$OOHQ:UHQFK
)RU,PSOHPHQW5RGV
HARDWARE
PACKAGE
/RFDWHDQGFKHFN
contents. Screws
VKRZQDFWXDOVL]H
ÀDWZDVKHUV
IRUZDOODQFKRUV
KROORZZDOO
DQFKRUVZLWKVFUHZVWR
VHFXUHKRRGWRWKHZDOODW
WKHERWWRP
4
VFUHZVWRVHFXUHWKH
ZRRGVXSSRUWDQGWWKH
KRRGWRWKHZDOO
3KLOOLSVKHDGVFUHZVWR
VHFXUHKRRGWRWKHZRRG
VXSSRUWVHFXUHGWR
ZRRGVXSSRUW
31-11016-1
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
+DPPHU
'XFWWDSH
(OHFWULFRUEDWWHU\RSHUDWHG
GULOODQGELWV
.H\+ROH6DZ
:LUHFXWWHU
VWULSSHU
URXQG
metal duct,
OHQJWKWR
suit installation.
3HQFLODQGWDSHPHDVXUH
6DIHW\JODVVHV
Wire nuts
3KLOOLSVDQGÀDW
EODGHVFUHZGULYHUV
6SLULWOHYHO
)ODVKOLJKW
Pliers
6WHSODGGHU
0HWDO6QLSV
6WUDLQUHOLHIIRU
MXQFWLRQFRYHU
CAUTION
/LIWWKHKRRGE\JUDVSLQJ
WKHRXWVLGHHGJHVRIWKHLQOHWRSHQLQJRIWKHKRRG
Do not lift the hood by grasping the exhaust opening or
transition duct with damper!
‡2SHQWKHFDUWRQDQGUHPRYHWKHKRRGDQG
SDFNDJLQJ
‡&RQ¿UPWKDWDOOKDUGZDUHDQGSDUWVDUHSUHVHQWE\
UHYLHZLQJWKHVHFWLRQQDPHG3DUWV3URYLGHGLQWKH
Installation Instructions.
‡/RRVHQWKHVFUHZVKROGLQJWKHZRRGVXSSRUWWR
WKHEDFNRIWKHKRRG5HPRYHZRRGVXSSRUW.HHS
ZRRGVXSSRUWDQGVFUHZV7KHVHZLOOEHXVHGWR
PRXQWWKHKRRGWRWKHZDOO
‡)XOO\LQVSHFWDQGFRQ¿UPWKDWDOOWDSHDQGSDFNLQJ
PDWHULDOKDVEHHQUHPRYHGIURPWKHKRRGDQG
WUDQVLWLRQGXFWZLWKGDPSHU
31-11016-1
9+]RU$PS
ZLUHZLWKJURXQG3URSHUO\
JURXQGHGEUDQFKFLUFXLW
Saber saw
or Sawsall
'RQRWOLIWIURPWUDQVLWLRQGXFW
+RRG
&DUWRQ
/LIWKRRGRXWRI
FDUWRQIURPWKHVLGHV
7RSYLHZRIRSHQVKLSSLQJFDUWRQ
5
Advance Planning
INSTALLATION CLEARANCES
7KHVHYHQWKRRGVDUHGHVLJQHGWREHLQVWDOOHGRQWRDZDOO
RUEHQHDWKDVRȻWRUFDELQHW
‡,QVWDOOWKHVHKRRGV0LQWR0D[DERYHWKH
FRRNLQJVXUIDFH
Note&OHDUDQFHVPD\YDU\GXHWRW\SHRIFRRNLQJSURGXFW
DQGORFDOFRGHV&KHFNZLWKORFDOLQVSHFWRUVWREHVXUH
VWDQGDUGLVDSSOLFDEOH
Soffit Installation
SOFFIT
OPTIONAL DUCT COVER
ACCESSORIES
6WDQGDUGGHFRUDWLYHGXFWFRYHUVDUHDYDLODEOHLQDQG
KHLJKWV'XFWFRYHUVPD\EHVWDFNHGLQYDULRXV
FRPELQDWLRQVWRFRQFHDOWKHGXFWZRUNUXQQLQJIURPWKH
WRSRIWKHKRRGWRWKHFHLOLQJ
‡%HIRUH\RXEHJLQ\RXVKRXOGGHWHUPLQHWKH
LQVWDOODWLRQKHLJKWRIWKHKRRGDQGRUGHUWKHFRUUHFW
VL]HGXFWFRYHU7KHGXFWFRYHUVVKRXOGEHRUGHUHGDW
WKHVDPHWLPHDVWKHYHQWKRRGDQGEHRQVLWHEHIRUH
LQVWDOODWLRQ2UGHUWKHGXFWFRYHUFRUUHVSRQGLQJWR\RXU
model.
Standard Duct Covers
6" Duct Cover
30" MIN.
36" MAX.
,QWKLVLQVWDOODWLRQWKHGXFWZRUNUXQQLQJIURPWKHWRS
RIWKHKRRGZLOOEHFRQFHDOHGLQWKHVRȻWRUXSSHU
cabinetry.
Wall Mount Installation
12" Duct Cover
6" Duct Covers
Hood Model
6” Duct Cover
=97=96 =;'&-
=97=96 =;'&-
=97=96 =;'&-
Dimensions
+[:['
+[:['
+[:['
12" Duct Covers
Hood Model
12” Duct Cover
=97=96 =;'&-
=97=96 =;'&-
=97=96 =;'&-
Dimensions
+[:['
+[:['
+[:['
30" MIN.
36" MAX.
)RUWKLVLQVWDOODWLRQDGHFRUDWLYHGXFWFRYHULV
DYDLODEOHWRFRQFHDOWKHGXFWZRUNUXQQLQJIURP
WKHWRSRIWKHKRRG8VHRIWKHGXFWFRYHUUHTXLUHV
VSHFLDOFRQVLGHUDWLRQWRWKHLQVWDOODWLRQKHLJKWDERYH
WKHFRXQWHUWRS
6
31-11016-1
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
7KHVHYHQWKRRGVPXVWEHLQVWDOOHGµPLQWRµ
PD[DERYHWKHVWDQGDUGµKLJKFRRNLQJVXUIDFH
ZKHQLQVWDOOHGRYHUDQ\SURIHVVLRQDOVW\OH
UDQJHWRSRUUDQJH7KHH[DFWKRRGLQVWDOODWLRQ
KHLJKWLVGHWHUPLQHGE\WKHFHLOLQJKHLJKW
1. 0HDVXUHWKHH[DFWFHLOLQJKHLJKW
2. 5HYLHZWKHFKDUWDWULJKWWRGHWHUPLQHWKHUDQJH
RISRVVLEOHKRRGLQVWDOODWLRQKHLJKWVWKDWFDQEH
DFFRPSOLVKHGZLWKRQHRUPRUHGXFWFRYHUV
3. ,QFUHDVHRUGHFUHDVHKRRGLQVWDOODWLRQKHLJKW
WRDFFRPPRGDWHWKH¿[HGRUGXFW
FRYHUVDQGXVHDZKROHQXPEHURIGXFWFRYHUV
RWKHUZLVHFXWWLQJDQGPRGLI\LQJRQHGXFWFRYHU
may be required.
4. 'XFWFRYHUVPD\EHVWDFNHGLQYDULRXV
FRPELQDWLRQVWRUHDFKFHLOLQJKHLJKWV
6WUDLJKWRU7DSHU6LGHG+RRGV
Duct Covers
18" Hood
Height
Ceiling Height
to Floor
Installation Height
Note0LQLPXPFHLOLQJKHLJKWIRU5($5:$//(;+$867
ZLWKGXFWFRYHUVLV
ZKHQLQVWDOOLQJDWDERYH
FRXQWHUWRSXVLQJHOERZ
*Possible
Actual
Hood
Ceiling Installation
Height
Height
6" Duct
Covers
12" Duct
Covers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
2
2
2
2
2
1
2
1
1
2
1
2
1
2
1
2
1
2
1
3
2
3
3
3
3
%DVHGRQFRXQWHUWRSKHLJKW
Note: $GGLWLRQDOGXFWFRYHUVPD\EHXVHGWR
UHDFKKLJKHUFHLOLQJV
31-11016-1
7
Advance Planning
ADVANCE PLANNING
POWER SUPPLY
,03257$173OHDVHUHDGFDUHIXOO\
Ductwork Planning
‡7KHVHYHQWKRRGVDUHHTXLSSHGIRUURXQG
GXFWZRUN)RUEHVWSHUIRUPDQFHXVHURXQG
GXFWZRUNRQWKHZLGHKRRGVDQG
KRRGVPD\EHWUDQVLWLRQHGWRURXQG
‡7KLVKRRGPD\EHYHQWHGYHUWLFDOO\WKURXJKXSSHU
FDELQHWVVRȻWRUFHLOLQJ$GXFWWUDQVLWLRQSLHFHLV
VXSSOLHGIRUYHUWLFDOH[KDXVW8VHORFDOO\VXSSOLHG
HOERZVWRYHQWKRUL]RQWDOO\WKURXJKWKHUHDUZDOO
‡'HWHUPLQHWKHH[DFWORFDWLRQRIWKHYHQWKRRG
• 3ODQWKHURXWHIRUYHQWLQJH[KDXVWWRWKHRXWGRRUV
7RPD[LPL]HWKHYHQWLODWLRQSHUIRUPDQFHRIWKH
YHQWV\VWHP
0LQLPL]HWKHGXFWUXQOHQJWKDQGQXPEHURI
transitions and elbows.
0DLQWDLQDFRQVWDQWGXFWVL]H
6HDODOOMRLQWVZLWKGXFWWDSHWRSUHYHQWDQ\
leaks.
'RQRWXVHDQ\W\SHRIIOH[LEOHGXFWLQJ
‡8VHPHWDOGXFWZRUNRQO\
‡,QVWDOODZDOOFDSRUURRIFDSZLWKGDPSHUDWWKH
H[WHULRURSHQLQJ2UGHUWKHZDOORUURRIFDSDQG
DQ\WUDQVLWLRQQHHGHGLQDGYDQFH
‡:KHQDSSOLFDEOHLQVWDOODQ\PDNHXSUHSODFHPHQW
DLUV\VWHPLQDFFRUGDQFHZLWKORFDOEXLOGLQJFRGH
requirements. Visit GEAppliances.comIRUDYDLODEOH
PDNHXSDLUVROXWLRQVVHDUFKRQWKHZRUGV´PDNH
XSDLUµRU´PDNHXSDLUµ
Wall Framing for Adequate Support
‡7KHVHYHQWKRRGVDUHKHDY\$GHTXDWHVWUXFWXUDO
VXSSRUWPXVWEHSURYLGHG+RRGVPXVWEHVHFXUHGWR
YHUWLFDOVWXGVLQWKHZDOO
‡,WLVVWURQJO\UHFRPPHQGWKDWWKHYHQWKRRGZLWKGXFW
FRYHUEHRQVLWHEHIRUH¿QDOIUDPLQJDQGZDOO¿QLVKLQJ
7KLVZLOODOVRKHOSWRDFFXUDWHO\ORFDWHWKHGXFWZRUNDQG
HOHFWULFDOVHUYLFH
Decorative Duct Covers:
'HFRUDWLYHGXFWFRYHUVDQGKLJKDUHDYDLODEOH
WR¿WDOOPRGHOV7KHGXFWFRYHUFRQFHDOVWKHGXFWZRUN
UXQQLQJIURPWKHWRSRIWKHKRRGWRWKHFHLOLQJRUVRȻW
6WDFNRQHRUPRUHGXFWFRYHUVRYHUWKHWRSRIWKHKRRG
WRUHDFK\RXUFHLOLQJKHLJKW
8
WARNING
)253(5621$/6$)(7<7+,6$33/,$1&(0867%(
3523(5/<*5281'(D.
5HPRYHKRXVHIXVHRURSHQFLUFXLWEUHDNHUEHIRUH
beginning installation.
Electrical supply
7KHVHYHQWKRRGVPXVWEHVXSSOLHGZLWK9+]DQG
FRQQHFWHGWRDQLQGLYLGXDOSURSHUO\JURXQGHGEUDQFK
FLUFXLWDQGSURWHFWHGE\DRUDPSFLUFXLWEUHDNHU
RUWLPHGHOD\IXVH
‡:LULQJPXVWEHZLUHZLWKJURXQG
‡,IWKHHOHFWULFDOVXSSO\GRHVQRWPHHWWKHDERYH
UHTXLUHPHQWVFDOODOLFHQVHGHOHFWULFLDQEHIRUH
SURFHHGLQJ
‡5RXWHKRXVHZLULQJDVFORVHWRWKHLQVWDOODWLRQORFDWLRQ
DVSRVVLEOHRQWKHEDFNZDOORUFHLOLQJ
‡&RQQHFWWKHZLULQJWRWKHKRXVHZLULQJLQDFFRUGDQFH
ZLWKORFDOFRGHV
Grounding instructions
7KHJURXQGLQJFRQGXFWRUPXVWEHFRQQHFWHGWR
DJURXQGPHWDOSHUPDQHQWZLULQJV\VWHPRUDQ
HTXLSPHQWJURXQGLQJWHUPLQDORUOHDGRQWKHKRRG
WARNING
7KHLPSURSHUFRQQHFWLRQRI
WKHHTXLSPHQWJURXQGLQJFRQGXFWRUFDQUHVXOWLQDULVN
RIHOHFWULFVKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRU
VHUYLFHUHSUHVHQWDWLYHLI\RXDUHLQGRXEWZKHWKHUWKH
DSSOLDQFHLVSURSHUO\JURXQGHG
31-11016-1
Installation Instructions
STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
‡8VHDOHYHOWRGUDZWKHFRRNWRSFHQWHUOLQHORFDWLRQ'UDZ
WKHOLQHWRFHLOLQJKHLJKW
‡0HDVXUHGHVLUHGGLVWDQFHIURPWKHERWWRPRIWKHKRRG
WRWKHFRRNLQJVXUIDFHPLQWRPD[
Note:,I\RXDUHLQVWDOOLQJWKHKRRGZLWKGXFWFRYHUVEHVXUHWR
UHDG´8VLQJ'XFW&RYHU$FFHVVRULHVµSDJH([DFWLQVWDOODWLRQ
KHLJKWPD\EHGHWHUPLQHGE\XVHRIRQHRUPRUHGXFWFRYHUV
‡8VHDOHYHOWRGUDZDVWUDLJKWKRUL]RQWDOSHQFLOOLQH
LQGLFDWLQJWKHERWWRPRIWKHKRRG
‡)URPWKHOLQHLQGLFDWLQJWKHERWWRPRIWKHKRRG
PHDVXUHXSDQGGUDZDQRWKHUOLQHIRUWKH
ORFDWLRQRIWKHZRRGVXSSRUW6HHLOOXVWUDWLRQ
FOR VERTICAL (Straight Up) DUCTING:
‡8VHDOHYHOWRGUDZDFHQWHUOLQHIURPWKHERWWRPRI
WKHKRRGWRFHLOLQJRUVRȻW
‡,IYHQWLQJRXWWKHFHLOLQJH[WHQGWKHFHQWHUOLQH
IRUZDUGRQWKHFHLOLQJRUVRȻW
‡/RFDWHWKHFHQWHUOLQHRIDKROHRQWKH
FHLOLQJRUVRȻWE\PHDVXULQJIURPWKHZDOO
House Wiring Location:
‡7KHMXQFWLRQER[LVIDVWHQHGWRWKHEDFNRIWKHKRRG
RQWKHULJKWVLGH
FOR DUCTING THROUGH REAR WALL:
‡0HDVXUHDERYHWKHPDUNHGOLQHIRUWKHWRSRI
WKHKRRG$WWKHFHQWHUOLQHPDUNORFDWLRQIRUD
GLDPHWHUKROH
Note0LQLPXQFHLOLQJKHLJKWIRU5($5:$//(;+$867
ZLWKGXFWFRYHUVLV
ZKHQLQVWDOOLQJDWDERYH
FRXQWHUWRSXVLQJHOERZ
18-1/16" for 48" Models
12-1/16" for 36" Models
9-1/16" for 30" Models
6-1/2"
8-3/8"
Electrical
Area
18-13/16" for 48" Models
12-13/16" for 36" Models
9-13/16" for 30" Models
‡7KHUHFHVVHGEDFNVLGHRIWKHKRRGSURYLGHVD
ODUJHDUHDIRUWKHKRXVHZLULQJWRH[LWWKHZDOODQG
EHURXWHGWRWKHUHDUNQRFNRXWDQGMXQFWLRQER[
‡5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXW,QVWDOO
VWUDLQUHOLHI
31-11016-1
Alternate Knockout Locations
,IWKHLQVWDOODWLRQUHTXLUHVWKHMXQFWLRQER[FDQEHUHORFDWHG
IURPWKHEDFNWRWKHWRSRIWKHKRRG5HPRYH
VFUHZVDOLJQER[WRWRSNQRFNRXWDQGVHFXUHZLWKRULJLQDO
screws.
‡5HPRYHMXQFWLRQER[FRYHUDQGNQRFNRXW,QVWDOO
VWUDLQUHOLHI
9
Installation Instructions
STEP 2A INSTALL HOOD ONTO WALL
SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR CABINET,
GO TO STEP 2B.
‡/RFDWHDWOHDVWYHUWLFDOVWXGVDWWKHZRRGVXSSRUW
‡)RUµPRGHOVLIYHUWLFDOVWXGVFDQQRWEHORFDWHGWKHQ
LQVWDOOVFUHZVWKURXJKWKHZRRGVXSSRUWLQWRWKHVWXGWKDWLV
ORFDWHGYHUWLFDOO\DOLJQHGZLWKWKHVFUHZVORFDWHGòµIURPWKH
HGJHRIWKHZRRGVXSSRUW
‡&HQWHUWKHVXSSOLHGZRRGVXSSRUWOHIWWRULJKWDQGEHORZWKH
PDUNHGOLQH
IMPORTANT: Framing must be capable of
supporting up to 150 lbs.
‡8VHGXFWWDSHWRVHDOWKHWUDQVLWLRQGXFWFRQQHFWLRQ&KHFNWREH
VXUHWKHGDPSHUPRYHVIUHHO\
Hang Hood On Wood Support
‡/LIWWKHKRRGDQGKROGFORVHWRWKHLQVWDOODWLRQORFDWLRQ
5RXWHKRXVHZLULQJWKURXJKWKHNQRFNRXWDQGLQWRWKH
MXQFWLRQER[
‡3ODFHWKHKRRGRYHUWKHZRRGVXSSRUW%HVXUHWKH
PRXQWLQJVFUHZVHQJDJHWKHNH\KROHVORWVLQWKHEDFNRI
WKHKRRG7LJKWHQWKHVFUHZV
Wood
Support
15-3/8"
30"
to
36"
30"
to
36"
Centerline of
Installation
Space
Centerline of
Installation
Space
‡6HFXUHWKHZRRGVXSSRUWWRRUPRUHYHUWLFDOVWXGV
XVLQJDWOHDVWRIWKHVXSSOLHGORQJVFUHZV)RUWKH
µPRGHO\RXPD\QHHGWRDGGIUDPLQJWRH[LVWLQJ
IUDPLQJWRVHFXUHWKHZRRGVXSSRUWWRVWXGV
IMPORTANT:6FUHZVPXVWSHQHWUDWHDWOHDVWLQWRYHUWLFDO
VWXGV&RXQWHUVLQNVFUHZVLQWRVXSSRUW
‡,QVWDOODGGLWLRQDOVFUHZVWRVHFXUHWKHKRRGWRWKHZRRG
VXSSRUW
‡'ULOOµSLORWKROHVLQWRWKHWZRORZHUKROHV,IWKHSLORW
KROHHQWHUVDVWXGXVHDZDVKHUDQGWKHORQJZRRG
VFUHZ,IWKHSLORWKROHGRHVQRWHQWHUDVWXGHQODUJHWKH
KROHWRµWRDFFHSWWKHZDOODQFKRUDQGXVHDZDVKHU
DQGWKHVFUHZIURPWKHZDOODQFKRU
Note: 7KHPRXQWLQJ
screws must remain in
WKHLURULJLQDOVKLSSLQJ
ORFDWLRQ7KHVHVFUHZV
DUHSRVLWLRQHGWR
HQJDJHWKHNH\KROH
VORWVLQWKHEDFNRIWKH
KRRG
Original Mounting
Screws as Shipped
1/4"
Gap
‡$GMXVWGHSWKRIRULJLQDOPRXQWLQJVFUHZVLQWKHZRRG
VXSSRUWXQWLOWKH\SURWUXGHIRUZDUG7KLVJDS
ZLOOSURYLGHFOHDUDQFHWRKDQJWKHKRRG
10
31-11016-1
Installation Instructions
STEP 2B Alternate Mounting Method
INSTALL HOOD TO SOFFIT OR BENEATH CABINETS
SKIP THIS STEP IF USING WALL MOUNTING METHOD
:KHQQHFHVVDU\WKHKRRGPD\EHLQVWDOOHGVRWKDWLWLV
VXSSRUWHGE\WKHVRȻW
‡7KHVRȻWVKRXOGEHFRQVWUXFWHGZLWK[·V
‡'HWHUPLQHWKHLQVWDOODWLRQORFDWLRQRQWKHZDOO
‡&RQWLQXHWKHFHQWHUOLQHIRUZDUGRQWKHERWWRPRI
WKHFDELQHWRUVRȻW
‡7KHRSHQLQJDERYHWKHKRRGVKRXOGDOORZIRUWKH
URXQGGXFWDQGFOHDUDQFHWRVOLGHWKHKRRG
EDFNDJDLQVWWKHZDOO
,03257$176RȺWIUDPLQJPXVWEHFDSDEOHRI
supporting up to 150 lbs.
‡8VHGXFWWDSHWRVHDOWKHWUDQVLWLRQGXFWFRQQHFWLRQ&KHFN
WREHVXUHWKHGDPSHUPRYHVIUHHO\
0RXQW+RRGRQWR6RȺWRU&DELQHW
Note: ,IPRXQWLQJWRWKHXQGHUVLGHRIDFDELQHWZLWKD
UHFHVVHGERWWRPLQVWDOOVKLPVWR¿OOWKHJDS
Cabinet
or
Soffit
Requires 10-1/2" Min.
Opening For Ductwork
and Hood Installation
Engage Top
Keyhole Slots
1/4" Gap
Push Back
to Wall
Add Shims
If Bottom
Is Recessed
Back
Wall
A
A
‡7KH[VWXGVPXVWEHORFDWHGDVVKRZQLQWKH
FKDUW'LP$WRDFFHSWPRXQWLQJVFUHZV
“A” Centerline to Stud
and Keyhole Slots
“B” Hood Width At
the Top
ZV48T
ZV48S
ZV36T
ZV36S
ZV30T
ZV30S
2"
A
7-1/2"
10"
‡'ULYHPRXQWLQJVFUHZVLQWRWKHVWXGVXQWLOWKH\
SURWUXGH7KHJDSZLOOSURYLGHFOHDUDQFH
WRHQJDJHWKHNH\KROHVORWVLQWKHWRSRIWKHKRRG
‡/LIWKRRGWRLQVWDOODWLRQSRVLWLRQ/RFDWHKRXVH
ZLULQJDQGURXWHWKURXJKWKHNQRFNRXWIURPWKH
EDFNRUWRSRIWKHKRRG
‡/LIWKRRGRQWRPRXQWLQJVFUHZV6OLGHEDFNDJDLQVW
WKHUHDUZDOO
‡7LJKWHQPRXQWLQJVFUHZV
IMPORTANT: For additional support and to
minimize vibration during operation, the hood must
be secured to the back wall. Use wall anchors to
fasten bottom back of hood to the wall.
Top View
Front of Hood
3/4"
2-9/16"
B
Back of Hood
‡'ULOOSLORWKROHVLQWRWKHVWXGVDWWKHORFDWLRQV
VKRZQLQWKHWRSYLHZLOOXVWUDWLRQ
31-11016-1
11
Installation Instructions
STEP 5 INSTALL DUCT COVERS
STEP 3 CONNECT DUCTWORK
‡,QVWDOOGXFWZRUNPDNLQJFRQQHFWLRQVLQGLUHFWLRQRI
DLUÀRZDVLOOXVWUDWHG
‡6HFXUHMRLQWVLQGXFWZRUNZLWKVKHHWPHWDOVFUHZV
‡:UDSDOOGXFWMRLQWVZLWKGXFWWDSHIRUDQDLUWLJKWVHDO
‡8VHGXFWWDSHWRVHDOWKHÀDQJHFRQQHFWLRQ5HDFK
LQVLGHWKHKRRGDQGSXVKWKHGDPSHUXSWREHVXUHLW
PRYHVIUHHO\
Duct Tape
Over Seam
and Screw
Air Flow
Note: )RUHDVLHUKDQGOLQJUHPRYHFDUGERDUGLQVHUWDIWHU
¿OPLVSHHOHGRȺ
5HPRYHSURWHFWLYH¿OPIURPGXFWFRYHUV,IPRUHWKDQ
RQHGXFWFRYHULVXVHGVHFXUHHDFKSLHFHWRJHWKHUZLWK
VFUHZVSURYLGHG
‡3ODFHWKHGXFWFRYHUVRQWRSRIWKHKRRG
‡)URPLQVLGHWKHKRRGVHFXUHWKHGXFWFRYHUWRWKH
WRSZLWKWKHVPDOO3KLOOLSVKHDGVFUHZVVXSSOLHG
ZLWKWKHFRYHUV
Screw
Duct Tape
Over Transition
STEP 4 CONNECT ELECTRICAL
9HULI\WKDWSRZHULVWXUQHGRȹDWWKHVRXUFH
WARNING:
,IKRXVHZLULQJLVQRW
ZLUHZLWKDJURXQGZLUHDJURXQGPXVWEHSURYLGHGE\
WKHLQVWDOOHU:KHQKRXVHZLULQJLVDOXPLQXPEHVXUHWR
XVH8/DSSURYHGDQWLR[LGDQWFRPSRXQG
DQGDOXPLQXPWRFRSSHUFRQQHFWRUV
A Remove
Junction Box
Cover
B Insert Power
Conduit Thru
Strain Relief
and Tighten
Ground
White
Black
C Use UL Listed
Wire Nuts
‡8VHZLUHQXWVWRFRQQHFWLQFRPLQJJURXQGWRJUHHQ
ZKLWHWRZKLWHDQGEODFNWREODFN
‡3XVKZLUHVLQWRMXQFWLRQER[DQGUHSODFHFRYHU%HVXUH
ZLUHVDUHQRWSLQFKHG
12
31-11016-1
Installation Instructions
STEP 6 INSTALL FILTERS
STEP 7 INSTALL IMPLEMENT RODS
Template for
Monogram
nameplate
Monogram
nameplate
‡3ODFH¿OWHUGULSWUD\VLQWRWKHUHDURIWKHKRRG
Screw
Stand-offs
Into
Hood
Use Allen
Wrench to
Secure Rod
to Stand-offs
‡,QVHUWWKHJUHDVH¿OWHULQWRWKHRSHQLQJDQGGURSLQWR
WKHWUD\V
‡7RUHPRYHWKH¿OWHUVJUDVSWKHKDQGOHSXVKWKH¿OWHU
XSDQGOLIWRXW
‡8VHDÀDWEODGHVFUHZGULYHUWRLQVWDOOVWDQGRȺV
LQWRWKHERWWRPRIWKHKRRG
‡$OLJQLPSOHPHQWURGWRVWDQGRȺVZLWKWKHVFUHZ
KROHWRZDUGVWKHLQVLGHRIWKHKRRG6HFXUHWKHURG
WRWKHVWDQGRȺVZLWKWKHVXSSOLHG$OOHQZUHQFK
‡)ROORZWKHVDPHSURFHGXUHRQWKHRSSRVLWHVLGH
‡,QVWDOONQREVOLQHXSWKHÀDWRQWKHVKDIWZLWKWKH
ÀDWLQWKHNQREKROH
‡$WWDFK0RQRJUDPQDPHSODWHEDGJH8VH
WKHWHPSODWHRQSDJHIRUDOLJQPHQWRIWKH
QDPHSODWH&XWRXWWKHWHPSODWHDQGWDSHLWRQWR
WKHKRRGIURQWVXUIDFHDQGYHULI\WKHWHPSODWHLV
DOLJQHGZLWKWKHOHIWVLGHRIWKHKRRGDQGZLWKLQWKH
XSSHUDQGORZHUHGJHRIWKHIURQWVXUIDFH3UDFWLFH
SODFLQJWKHQDPHSODWH¿UVWEHIRUHUHPRYLQJWKH
DGKHVLYHUHOHDVHSDSHU
FINALIZE INSTALLATION
‡,QVWDOOWKHVXSSOLHGLQIUDUHGEXOEV
‡6HHWKH2ZQHU·V0DQXDOIRULQVWUXFWLRQVWRWHVW
RSHUDWLRQ
31-11016-1
13
14
5HPRYHDQGGLVFDUGWKLVWHPSODWH
$IWHUWKLVSUDFWLFHUHPRYHWKHUHOHDVHSDSHUIURPWKHEDFNRIWKHQDPHSODWH
EDGJHDQGDWWDFKWKHQDPHSODWHEDGJHWRWKHKRRGZLWKRXWDQ\RYHUODSRIWKH
QDPHSODWHEDGJHWRWKLVWHPSODWH
%HIRUHUHPRYLQJWKHUHOHDVHSDSHUIURPWKHEDFNRIWKHQDPHSODWHEDGJH
SUDFWLFHSODFLQJWKHQDPHSODWHEDGJHLQWKHSURSHUSRVLWLRQRQWKHKRRG
ZLWKRXWDQ\RYHUODSEHWZHHQWKHQDPHSODWHEDGJHDQGWKLVWHPSODWH
NOTE:7KHQDPHSODWHEDGJHKDVYHU\KLJKUHWHQWLRQDGKHVLYH²RQFHWKH
QDPHSODWHEDGJHLVDWWDFKHGLWLVH[WUHPHO\GLȻFXOWWRUHPRYH
Monogram Nameplate Template
7ULP$URXQG'RWWHG/LQH
31-11016-1
Notes
31-11016-1
15
Note: :KLOHSHUIRUPLQJLQVWDOODWLRQVGHVFULEHGLQWKLVERRN
VDIHW\JODVVHVRUJRJJOHVVKRXOGEHZRUQ
For Monogram® local service in your area, call
1.800.444.1845.
Note: 3URGXFWLPSURYHPHQWLVDFRQWLQXLQJHQGHDYRUDW
*HQHUDO(OHFWULF7KHUHIRUHPDWHULDOVDSSHDUDQFHDQG
VSHFL¿FDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH
31-11016
07-15 GE
monogram.com
Printed in Italy
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement