advertisement
▼
Scroll to page 2
of 4
Read this document carefully before using this device. The guarantee will be expired by device damages if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages. ENDA EPV241A AC/DC VOLTMETER Thank you for choosing ENDA EPV241 AC/DC voltmeter. * 77 x 35mm sized. * 3 digits display. * Values between -100V and 100 V can be indicated with one decimal point. * For maximum 50V AC/DC measurements;10 times the sensitivity of the measurement values between -50V and +50V with two decimal places to show. * Easy to configure with front panel keypad. * Multifunctional alarm output (NO+NC) for upper and lower limits. * With insulated rs485 ModBus protocol communication feature.(optional) * CE marked according to Europan Norms. * Measuring type can be selected AC, DC or True RMS. 1-Output R......Relay None...No relay Technical Specifications OUT AC DC ACDC V SET ENDA EPV 241A Order Code : EPV241A- - - 3 2-Supply Voltage 3-ModBus RSI..... Insulated ModBus (optional) 230VAC...230V AC 110VAC...110V AC 24VAC.....24V AC SM...........9-30V DC / 7-24V AC 1 2 ENVIRONMENTAL CONDITIONS Ambient/stroge temperature Max. Relative humidity 0 ... +50°C/-25 ... 70°C Relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C. Rated pollution degree Height According to EN 60529 Max. 2000m Front panel : IP65 , Rear panel : IP20 Do not use the device in locations subject to corrosive and flammable gases. ELECTRICAL CHARACTERISTICS 230V AC +10% -20%, 50/60Hz or 24V AC ±10% , 50/60Hz or optional 9-30V DC / 7-24V AC ±10% SMPS Max. 5VA 2.5mm² screw-terminal connections If C.inP ;50 is selected,it is 0....50V AC and RMS If C.InP; 500 is selected,it is 0V...500V or If C.InP ;500 is selected, it is -500V DC....500V DC or If C.InP;50 is selected,it is -50V DC....50V DC DC 0,01V (If C.InP;50 is selected ) 0,1V (If CINP;500 is selected and higher than -100V or lower than 100V for input values) 1V (If CINP;500 is selected and lower than -100V or higher than 100V for input values) Supply Power consumption Wiring Scale up to date: 01022014, modification reserved and can be change any time previous notice ! Sensitivity Accuracy Input Range ± 1% (Full scale) (For square wave form ± 2%) ± 1% (Full scale) ± 1% (Full scale) (For square wave form ± 2%) -500V...500V (If CINP 500 is selected,device breaks down at more than ±1250 DC voltages.) AC DC RMS Frequency Range -50V....50V (If cInp 50 is selected,device breaks down at more than ±125 DC voltages.) 870kÙ DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz) EMC EN 61326-1: 2006 Safety requirements EN 61010-1: 2010 (Pollution degree 2, overvoltage category II) Input Impedance OUTPUTS Alarm output Life expectancy for relay Relay: 250V AC, 8A (for resistive load), NO+NC Mechanical 30.000.000 ; Electrical 100.000 operation. HOUSING Housing type Dimensions Weight Suitable for flush-panel mounting. (According to DIN 43 700) W77xH35xD71mm Approx. 350g (after packing) Enclosure material Self extinguishing plastics. While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. SURAN Industrieelektronik Dettinger Str. 9 / D-72160 Horb a.N Tel.: +49 (0)7451 / 625 617 Fax: +49 (0)7451 / 625 0650 E-mail : [email protected] Internet : www.suran-elektronik.de 1./4 EPV241A-E AC ENDA OUT DC ACDC 77mm EPV 241A SET V Panel 71mm Panel cut-out 2 61mm Depth Rubber packing 5mm Line Neutral 4 5 Fuse F 100mA 250V AC Switch 230V AC Supply Holding screw 0.4-0.5Nm. Faz Nötr 4 5 Cable Size: 1,5mm²; Equipment is protected throughout by DOUBLE INSULATION Fuse should be connected. Note: 1) Mains supply cords shall meet the requirements of IEC 60227 or IEC 60245. 2) In accordance with the safety regulations, the power supply switch shall bring the identification of the relevant instrument and it should be easily accessible by the operator. 184-253V AC 50/60Hz 5VA SUPPLY: NOTE : Note : 1) Panel thickness should be maximum 7mm. 2) If there is no 60mm free space at the back side of the device, it would be difficult to remove it from the panel. To remove the device from panel: - While pushing the the flushmounting clamp in direction 1,pull out it in direction 2. 2 4 5 6 230V AC +10% -20% 50/60Hz 5VA 3 7 8 9 11 12 SN: XXXXXXXXX 10 + Max. 50V AC / DC + Max. 500V AC / DC 1 2 3 4 5 6 7 OUTPUT 250V AC 8A 230V AC +10% -20% RESISTIVE LOAD 50/60Hz 5VA 8 9 10 + 11 12 AC / DC Max. 50V AC / DC + Max. 500V 8 680407 704927 CAT II Made in Turkey PROGRAMMABLE AC/DC VOLTMETER EPV241A-R-230VAC SN: XXXXXXXXX 8 680407 704903 Made in Turkey ENDA INDUSTRIAL ELECTRONICS 1 CAT II PROGRAMMABLE AC/DC VOLTMETER EPV241A-230VAC ENDA INDUSTRIAL ELECTRONICS 3 4 5 6 COM. 230V AC +10% -20% 50/60Hz 5VA 7 B 8 A 9 11 12 SN: XXXXXXXXX 10 + AC / DC Max. 50V AC / DC + Max. 500V 1 2 3 4 5 6 COM. OUTPUT 250V AC 8A 230V AC +10% -20% RESISTIVE LOAD 50/60Hz 5VA 7 B 8 A 9 10 + 11 12 Max. 50V AC / DC AC / DC + Max. 500V 8 680407 704934 CAT II Made in Turkey PROGRAMMABLE AC/DC VOLTMETER EPV241A-R-230VAC-RSI 2 SN: XXXXXXXXX 8 680407 704910 Made in Turkey ENDA INDUSTRIAL ELECTRONICS 1 CAT II PROGRAMMABLE AC/DC VOLTMETER EPV241A-230VAC-RSI ENDA INDUSTRIAL ELECTRONICS If Cýnp input type “50” is selected, the measurement terminals 10 and 11 of the terminals must be connected.Otherwise the measurement is done incorrectly. If C.Inp input type “500” is selected, the measurement terminals 9 and 12 of the terminals must be connected.Otherwise the measurement is done incorrectly. ENDA EPV241A is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling.Make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. 1 Flush mounting clamp Connection Diagram 35mm Dimensions 29mm Out -A 0 A 0 A 0 A -A 0 A 0 A 0 A -A 0 A d A.out = n.c. T/2 T/2 T/2 T/2 T/2 T/2 Out A.out = n.o. LO.l1 - HYS.L LO.l1 LO.l1 + HYS.L UP.l1 + HYS.U UP.l1 UP.l1 - HYS.U Input T d T T T T T T 3T/2 3T/2 3T/2 3T/2 3T/2 3T/2 dly.U 2T 2T 2T 2T 2T 2T dly.U A A 1 3 d T A 1 2 A d2 2 T 0.386 A 0.308 A A 1 2 ac dly.l 0.000 A d T A 1 2 0.000 p A1 p A 2 0.000 dc d T t 2./4 EPV241A-E A 1 3 A A 1 2 A A 1 2 t t (rms) A 1 2 A 1 2 Ac.dc dly.l EPV241 PROGRAMMING DIAGRAM OUT OUT ACAC DC DC ACDC ACDC V V SET SET Increment key Used for increasing the setpoint value and changing parameters. When held down for a few seconds, configured numeric value increases faster. . Decrement key Used for decreasing the setpoint value and changing parameter. When held down for a few seconds, configured numeric value decreases faster. SET ENDA ENDA Programming key EPV EPV241A 141 Used for displaying and configuring the selected parameter value. ADJUSTING THE ALARM VALUE SET SET By using & Measurement value If this key is pressed, upper limit value appears. If both keys are pressed, upper limit value can be adjusted. and keys, upper limit value can be adjusted between -500V and 500V. If C.Inp;it is 50, this parameter adjustable between -50.00V-50.00V. This parameter can’t be lower than (lo.l1 + HYS.l + HYS.U ) value. Or SET SET By using & and keys, upper limit value can be adjusted between -500V and 500V. If C.Inp;it is 50, this parameter adjustable between -50.00V-50.00V. If this key is pressed, upper limit value appears. If both keys are pressed, lower limit value can be adjusted. This parameter can’t be lower than (UP.L1 - HYS.l - HYS.U ) value. Measurement value Measurement value Loc If unL key is pressed, “Loc” mode is entered. If key is pressed, “unL” mode is entered. uNL mode; the menu and other functions can be accessed. Loc mode; the menu can not be accessed and other functions. It can be seen only the measured value Measurement value 12.03 & & 2013 If keys are pressed together,revision date,day and month are displayed. If both & While the revision date is shown as day/month,if keys are pressed and held for 3 seconds,programming mode is entered.If value made. & key is pressed the revision date is displayed as year. keys are pressed while parameter names are displayed,then it returns to mensured PROGRAMMING MODE Upper limit value SET By using and keys, upper limit value can be adjusted between -500V and 500V. If C.Inp;it is 50, this parameter adjustable between -50.00V-50.00V. If this key is pressed, upper limit value appears. ( This parameter can’t be lower than (lo.l1 + HYS.l + HYS.U ) value. SET If SET key is pressed, it returns to parameter name. Hysteresis value for upper limit If this key is pressed, hysteresis value for upper limit appears 10.0 Delay time for upper limit alarm SET By using and keys, hysteresis value for upper limit can be adjusted between 0.0V and 20.0V. If C.Inp;it is 50, this parameter adjustable between 0.00 and 20.00. This parameter can’t be higher than ( Up.l1 - Lo.l1 - Hys.l ) value. SET If key is pressed, it returns to parameter name. By using and keys, delay time for upper limit alarm can be adjusted between 0 and 900 seconds. SET If this key is pressed, delay time for upper limit appears If key SET By using keys, lower limit value can be adjusted between -500V and 500V. SET If key is pressed, it returns to parameter name. Hysteresis value for lower limit SET SET and If C.Inp;it is 50, this parameter adjustable between -50.00V-50.00V. This parameter can’t be higher than (UP.l1 - HYS.U - HYS.L ) value. If this key is pressed, lower limit value appears. If this key is pressed, hysteresis value for lower limit appears is pressed , it returns to parameter name. Lower limit value 10.0 By using and keys, hysteresis value for lower limit can be adjusted between 0.0V and 20.0V. If C.Inp;it is 50, this parameter adjustable between 0.00 and 20.00. This parameter can’t be higher than ( Up.l1 - Lo.l1 - Hys.U ) value. SET If key is pressed,it returns to parameter name. Delay time for lower limit alarm By using and key,s delay time for lower limit alarm can be adjusted between 0 and 900 seconds. If this key is pressed, delay time for lower limit appears SET SET If key is pressed ,it returns to parameter name. Alarm output position By using and keys, alarm output state can be adjusted to n.o. or N.c. If it is adjusted no, output relay is powered at alarm condition. If this key is pressed, alarm output state appears. SET If key is pressed ,it returns to parameter name. 3./4 EPV241A-E SET * Measuring type ACdC If this key is pressed, measuring type appears. By using and SET If key SET * If this key is pressed, sampling time measurement value appears. 4 Sampling time of the measurement value is shown on the screen. If the 1 selected;sampling time of the measurement is 250ms, If 2 is selected,it is 500ms.If 3 is selected, it is 750ms.If 1 is selected,it is 1 second. SET If key is pressed, it returns to parameter name. SET 1 If this key is pressed, address of the device appears. ** baud is pressed,it returns to parameter name. Sampling time measurement value Optn ** Adrs By using and If key is pressed, it returns to parameter name. SET OFF By using and keys, baudrate value of the device can be adjusted to OFF,1200,2400,4800,9600,19200. SET If SET C.Inp keys address of the device can be adjusted between 1-247. SET When this key is pressed, baudrate is seen. * keys, measuring type can be adjusted to ac , dc or acdc.Three leds at the top of the display show measuring type. key is pressed,it returns to parameter name. 500 When this key is pressed, measurement input type s seen. (*) There are only ,tYPE, optn, CInp parameters in the devices those have no relay. (**)The AdrS and baud parameters are only in the devices those have modbus. If any key is pressed in 25 seconds or the device is powered down and powered upþ,then it returns to operation mode. NOTE: If key is held down while the device is powered up, the d.PAr message will appear and the factory settings will be restored. Factory settings restored after CInp;50,HYSL and HYSU are set to “1.00” If C.Inp input type “500” is selected, the measurement terminals 9 and 12 of the terminals must be connected.Otherwise the measurement is done incorrectly. If Cýnp input type “50” is selected, the measurement terminals 10 and 11 of the terminals must be connected.Otherwise the measurement is done incorrectly. ERROR MESSAGES Means, measured current value is higher than maximum scale. Means, measured current value is lower than minimum scale. 4./4 EPV241A-E
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project