VDW Series Compact Direct Operated 2-3 Port Solenoid Valve for Water, Air

VDW Series Compact Direct Operated 2-3 Port Solenoid Valve for Water, Air
Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air
Series VDW
VDW10/20/30: 2 Port, VDW200/300: 3 Port
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
VXF
VX3
VXA
VCH첸
VDW
VQ
LVM
VCA
VCB
VCL
VCS
VCW
Molded coil specifications have been added!
IP65
Compact / Lightweight
(as compared to the VX series)
Single valve volume: Reduced by –75% (VDW20)
100 g: Reduced approx. by –50%
(for orifice diameter equivalent to ø2)
Grommet/Molded
FastonTM terminal Note)/Molded
Note) FastonTM is a trademark of Tyco Electronics Corp.
241
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
For Water and Air Compact Direct Operated 2/3 Port Solenoid Valve
Series VDW
• Compact (as compared to the VX series)
Single valve volume: Reduced by –75% (VDW20)
Manifold length: Reduced by –18% (VDW30, 7 stations)
• Lightweight (as compared to the VX series)
100 g: Reduced approx. by –50%
(for orifice diameter equivalent to ø2)
Improved durability (Nearly twice the life of the previous series)
The use of a unique magnetic
material reduces the operating
resistance of moving parts, while
improving service life, wear and
corrosion resistance.
Clip type
Ease of maintenance has been
improved.
Changing of the coil is made easy by
means of clip design. (2 port)
Threaded assembly
Improved corrosion resistance
Simplifies maintenance.
Special material introduced
Brass (C37)/Stainless
steel manifolds added
to series (2 port)
High flow rate: Cv factor
0.04 to 0.46 (2 port)
Universal porting
VDW200/300 (3 port)
Improved environment resistance
Environment resistance is improved by using a
molded coil. (Enclosure IP65 or equivalent,
grommet mold)
Threaded for
bottom mounting
Special bracket can be
mounted.
Grommet/Molded
Lineup by Compact Design
2 Port
ø17
ø17
VDW10
3 Port
P.243
P.254
ø28
ø28
ø20.5
ø20.5
VDW30
VDW200
ø28
ø28
ø20.5
ø20.5
VDW20
VDW300
242
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-02-22-VDW10.qxd
09.10.1 1:27 PM
Page 1
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
VX2
How to Order Valves (Single Unit)
VD W 2 1
1 G
2
VXD
01
VXZ
For Water, Air, Vacuum
CE compliant
Series
1
2
3
10
20
Valve type
30
N.C.
None
F
Foot bracket
VXF
Body
material
Seal
material
NBR
200 VAC (50/60 Hz)
Brass (C37)
FKM
Nil
110 VAC (50/60 Hz)
A
B
G
H
J
220 VAC (50/60 Hz)
24 VDC
12 VDC
6 VDC
5 VDC
Stainless
steel
Class B
FKM
Coil type
G – Grommet / Tape winding
Thread type
W – Grommet / Molded
Nil
Rc
F
N
NPT
F – Faston terminal / Molded
VCA
VCB
VCL
G
VCS
VCW
Port size
Magnet wire protection: Tape winding Magnet wire protection: Resin Molded
VQ
LVM
FKM
Note) The armature assembly is a
corrosion resistant construction.
∗ Please consult with SMC regarding other voltages.
VCH첸
VDW
EPDM
L Note)
3 VDC
Coil
insulation
EPDM
NBR
VX3
VXA
Material and insulation type
Symbol
VXP
VXR
Note) The foot bracket is
packed with a valve.
Grommet / Faston
Grommet /
Tape
terminal,
winding (G) Molded (F) Molded (W)
VXE
VXH
Nil
Voltage
100 VAC (50/60 Hz)
CE compliant
Option
(1)
IN
1
2
3
4
5
6
V
S
R
Q
(Refer to page 244.)
1
Voltage
—
Made to Order
OUT
(2)
Symbol
Nil
Symbol
Port size
M5
01
02
Series
10
20
M5
쑗
1/8 (6A)
—
쑗
쑗
1/4 (8A)
—
—
30
—
쑗
쑗
Orifice diameter
Symbol
Magnet wire protection: Resin Molded
Series and Coil Type Combinations
Series Grommet / Tape winding Faston terminal / Molded
10
20
30
Grommet / Molded
1
2
1
2
3
2
3
4
Orifice diameter
(mm ø)
1
1.6
Series
10
1.6
2.3
20
3.2
2
3
30
4
243
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW10/20/30
Standard Specifications
Direct operated poppet
Valve specifications
Valve construction
Fluid Note 2)
Water (except waste water or agricultural water), Air, Low vacuum
Withstand pressure (MPa)
2.0
Ambient temperature (°C)
–10 to 50
1 to 50 (No freezing)
Fluid temperature (°C)
Location without corrosive or explosive gases
Environment
Valve leakage (cm3/min)
0 (with water pressure) 1 or less (Air)
Unrestricted
Mounting orientation
Coil specifications
Vibration/Impact (m/s2) Note 4)
30/150
24 VDC, 12 VDC, 6 VDC, 5 VDC, 3 VDC,
100 VAC, 110 VAC, 200 VAC, 220 VAC (50/60 Hz)
Rated voltage
±10% of rated voltage
Allowable voltage fluctuation (%)
Class B
Coil insulation type
Dust-proof (equivalent to IP40)
Grommet / Tape winding
Enclosure
Dust-tight (equivalent to IP60) Note 5)
Faston terminal / Molded
Dust-tight / Low jetproof (equivalent to IP65)
Grommet / Molded
Power consumption (W) Note 3)
Made to
Order
Note 1) When used under conditions which may cause condensation on the exterior of the product,
select Grommet / Molded.
Note 2) When used with deionized water, select “L” (Stainless steel, FKM) for the material type.
Note 3) Since the AC coil specification includes a rectifier element, there is no difference in power consumption between inrush and holding.
In the case of 110/220 VAC, the VDW10 is 3 W and the VDW20/30 is 3.5 W.
Note 4) Vibration resistance ····· No malfunction when tested with one sweep of 5 to 200 Hz in the axial
direction and at a right angle to the armature, in both energized and
deenergized states.
Impact resistance ········ No malfunction when tested with a drop tester in the axial direction and
at a right angle to the armature, one time each in energized and
deenergized states.
Note 5) Since electrical connections are exposed, there is no water resistance.
Made to Order
(For details, refer to page 259.)
Symbol
X22
2.5 (VDW10), 3 (VDW20/30)
Characteristic Specifications
Specifications
Non-leak (10-6 Pa·m3/sec) /
Vacuum (0.1Pa·abs) specification
X23
X60 Lead wire length: 600 mm specification
X133 Seal material: Kalrez® specification Note)
Oil-free specification
Model
Port size
VDW10
M5
VDW20
M5
1/8 (6A)
®
Note) Kalrez is a registered trademark of DuPont Dow
Elastomers.
VDW30
1/8 (6A)
1/4 (8A)
Orifice dia.
(mm ø)
Max. operating pressure
differential (MPa) Note 1)
Operating
Pressure range
Note 2)
Pressure port 1 Pressure port 2 (MPa)
1
0.9
0.4
1.6
0.4
0.2
1.6
0.7
0.2
2.3
0.4
0.1
3.2
0.2
0.05
2
0.8
0.2
3
0.4
0.1
4
0.2
0.05
Mass
(kg)
0.08
0.1
0 to 1.0
1/8: 0.23
1/4: 0.26
Note 1) The maximum operating pressure differential changes depending on the flow direction of the
fluid. Refer to page 264 for details.
Note 2) For low vacuum specifications, the operating pressure range is 1 Torr (1.33 x 102 Pa) to 1.0
MPa.
Please consult with SMC if using below 1 Torr (1.33 x 102 Pa).
Flow Characteristics
Model
VDW10
VDW20
VDW30
Port size
M5
M5
1/8 (6A)
1/8 (6A)
1/4 (8A)
Orifice dia.
(mm ø)
N.C.
1
Water
Air
1→2 (IN→N.C.)
1→2 (IN→N.C.)
Av x 10–6 m2 Cv converted C [dm3/(s·bar)]
0.04
0.96
0.14
b
0.40
Cv
0.04
1.6
1.7
0.07
0.30
0.25
0.07
1.6
1.9
0.08
0.31
0.45
0.09
2.3
4.3
0.18
0.58
0.45
0.18
3.2
7.2
0.30
1.2
0.38
0.33
2
3.8
0.16
0.52
0.52
0.16
3
6.7
0.28
1.0
0.52
0.30
0.44
1.5
0.49
0.46
4
11
244
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
Construction
VDW11
VDW21
i
i
w
w
e
e
VX2
r
r
VXD
u
VXZ
u
VXE
t
y
t
y
VXP
VXR
q
q
VXH
VXF
VX3
VXA
VDW31
i
VCH첸
w
VDW
VQ
e
LVM
r
u
VCA
No.
t
y
q
VCB
Component Parts
Description
Material
Standard
Option
Brass (C37)
Stainless steel
Tube assembly
Stainless steel
—
Coil assembly
—
—
1
Body
2
3
4
Armature assembly Stainless steel, PPS, NBR
FKM, EPDM
5
O-ring (Body)
NBR
FKM, EPDM
6
Return spring
Stainless steel
—
7
Cover
SPCE
—
8
Clip
Stainless steel
—
VCL
VCS
VCW
245
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW10/20/30
Dimensions
VDW11-쏔WG
VDW21-쏔WG
22
20
Lead wire
Lead wire
l Approx. 300
Rectifier
element
AC type
14
2 x ø3.2
20
27
27
21
l Approx. 300
Rectifier
element
AC type
20
2 x ø3.5
27
20
ø20.5
48
56
ø17
5
5
8
1
6
1
M5
1 (IN) port
M5, 1/8
2 (OUT) port
M5, 1/8
1 (IN) port
11
15
M5
2 (OUT) port
2 x M3 x 5
2 x M2.5 x 3.5
VDW31-쏔WG
36 (27.6)
1
1
30
SMC
SMC
40
Lead wire
l Approx. 300
Rectifier element
AC type
4 x ø5
25
34
ø28
Bracket assembly part no.
쎲
Series 10, 20
65 (61.5)
VDW 2 0
15A 1
6
8.5 (6.3)
Series
1/8, 1/4
2 (OUT) port
1/8, 1/4
1 (IN) port
1
2
쎲
10
20
Series 30
VCW20
12
01A
12.8
Dimensions inside ( ) are for port size 1/8.
2 x M4 x 6
246
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
Dimensions
VDW31-쏔F
20
30
VX2
14
34
25
11.4
6.35
40
6.35
27
20
27
VDW21-쏔F
2 x ø3.5
(Bracket mounting hole)
SMC
VXD
4 x ø5
VXZ
36.5
20.5
10.5
VDW21-*F*-***-*-*
9
VXP
VXR
VXH
8.5 (6.3)
55.8
5
8
M5, 1/8
1 (IN) port
VXF
6
22
M5, 1/8
2 (OUT) port
VXE
28
17.5
VDW31-*F*-***-*-*
56
46.2
M3.5
(for grounding)
66 (62.5)
14.3
0.8
M3.5
(for grounding)
9
0.8
29.6
6.7
36 (27.6)
1/8, 1/4
2 (OUT) port
VX3
1/8, 1/4
1 (IN) port
VXA
VCH첸
2 x M3 x 5
2 x M4 x 6
VDW
15
12.8
VQ
LVM
Bracket assembly part no.
쎲
VDW20
쎲
VCA
Series 20
VCB
15A 1
VCL
Series 30
VCW20
12
01A
VCS
VCW
247
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-02-22-VDW10.qxd
09.10.1 1:27 PM
Page 2
Series VDW10/20/30
How to Order Manifold
VV2DW 2
How to Order Manifold Assembly
05 01
Series
1
2
3
CE compliant
10
20
30
—
CE compliant
Nil
Q
Option
None
With bracket
Nil
Material
Symbol Manifold material Seal material
NBR
Nil
Brass (C37)
FKM
A
EPDM
B
NBR
G
Stainless
FKM
H
steel
EPDM
J
F
Note) Series 30 is
available with
bracket only.
Enter the mounting valve and option part numbers
under the manifold base part number.
<Ordering example>
VV2DW2-0501 ········ 1 set Manifold part no.
∗VDW23-5G-2 ········· 5 sets Valve part no.
(Stations 1 to 5)
“∗” is the symbol for assembly. Add an “∗” in
front of the part numbers
to have solenoid valves,
etc. mounted on manifold.
02
10
F
N
10 stations
3
2
ide
Ds
1
OUT port size
Series
10 20 30
쑗 쑗 –
– 쑗 쑗
– – 쑗
Symbol Port size
M5
01
02
M5
1/8 (6A)
1/4 (8A)
Note) IN port sizes are as
follows.
10: 1/8 (6A)
20: 1/4 (8A)
30: 3/8 (10A)
How to Order Valves (For Manifold)
VDW 2 3
4
Rc
G
NPT
Nil
2 stations
5 G
2
CE compliant
Series
1
2
3
ide
Us
5
Thread type
Stations
Enter together in
order, counting
from station 1 on
the D side.
Nil
10
20
30
Q
Valve type
3
Material and insulation type
N.C. for manifold
Voltage
Symbol
Voltage
1
2
3
4
5
6
V
S
R
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
—
CE compliant
Grommet / Faston
Grommet /
Tape
terminal,
winding (G) Molded (F) Molded (W)
Symbol Body material Seal material
NBR
Nil
Brass (C37)
FKM
A
EPDM
B
NBR
G
FKM
H
Stainless
EPDM
steel
J
FKM
L Note)
Coil insulation
Class B
Note) The armature assembly is a corrosion resistant construction.
Orifice diameter
Coil type Note)
G Grommet / Tape winding
F Faston terminal / Molded
W Grommet / Molded
∗ Please consult with SMC regarding other voltages.
Note) About series and coil type
combinations, refer to page
243.
Manifold Options
Symbol Orifice diameter (mmø)
1
1
1.6
2
1.6
1
2.3
2
3.2
3
2
2
3
3
4
4
Series
10
20
30
Blanking plate assembly
쎲
쎲
Series 10, 20
VVDW 2 0 3A
Series
1
2
10
20
Series 30
VVCW20 3A
Material
Symbol Plate material Seal material
NBR
G
FKM
Stainless steel
H
EPDM
J
∗ Plate material is stainless steel only.
Material
Symbol Plate material Seal material
NBR
G
FKM
Stainless steel
H
EPDM
J
248
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
Dimensions
16
(19.6)
VV2DW1
VX2
VXD
VXZ
VXE
Approx. 300
VXR
3.4
7
1.
24.4
VXF
13.4
16.3
(1.5)
8.8
8.8
P = 17.5
2 x ∗1/8 (IN port)
(∗: Thread type)
VX3
2.8
(2.8)
30
VXH
9.4
(4.4)
R
34
VXP
1
VXA
L1
L2
VCH첸
L3
Stations
D side
2
1
3
4
5
n
VDW
U side
VQ
LVM
VDW13-*G-* VDW13-*G-* VDW13-*G-* VDW13-*G-*
VCA
61
n x M5
(OUT port)
P = 17.5
7.7
26.5
19.6
VCL
VCS
1.5
13
VCB
8.1
VCW
4 x M3 x 0.5
11.5
7.7
11.5
7.7
(16.3)
∗ When w/o bracket, M3 threads
at both ends (4 locations) can
be used for other purposes.
5
22.5
40
7.5
L Dimension
Dimension
(mm)
n (stations)
2
3
4
5
6
7
8
9
10
L1
35
52.5
70
87.5
105
122.5
140
157.5
175
L2
45
62.5
80
97.5
115
132.5
150
167.5
185
L3
52
69.5
87
104.5
122
139.5
157
174.5
192
Manifold composition 2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. x 2
Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Refer to page 252 and 253 regarding manifold additions.
249
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW10/20/30
Dimensions
16
(25.5)
VV2DW2
2 x ∗1/4 (IN port)
(∗: Thread type)
L1
L2
L3
D side
1
2
3
4
VDW23-*G-*
VDW23-*G-*
VDW23-*G-*
VDW23-*G-*
5
U side
n
n x M5 x 0.8
n x ∗1/8
(OUT port)
11
54
6
10
24
46
10
21
31.5
9.5
11
32
11
6
4.5
P = 22
9.5
(19.5)
11
1.5
18.5
70
Stations
.3
9
R2
4.5
33
4.6
24
(19.5)
16
19.5
1
11 Approx. 300
1
4 x M4
∗ When w/o bracket, M4 threads
at both ends (4 locations) can
be used for other purposes.
L Dimension
Dimension
(mm)
n (stations)
2
3
4
5
6
7
8
9
10
L1
44
66
88
110
132
154
176
198
220
L2
53
75
97
119
141
163
185
207
229
L3
62
84
106
128
150
172
194
216
238
Manifold composition 2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. x 2
Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Refer to page 252 and 253 regarding manifold additions.
250
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
(26.5)
VV2DW3
VX2
23
VXD
VXZ
VXE
VXP
VXR
38
28
2 x ∗3/8 (IN port)
(∗: Thread type)
10.5
VXF
L1
L2
L3
VX3
VXA
5
.2
R2
5.5
VXH
(24.5)
20
24.5
49
14.7
4.5
Approx.
300
2.5
VCH첸
VDW
D side
Stations
2
1
3
4
n
5
U side
VQ
LVM
VDW33-*G-*
VDW33-*G-*
VDW33-*G-*
VCA
VDW33-*G-*
83
VCB
16
21
34
VCL
17.25
VCW
5.5
n x ∗1/8
n x ∗1/4
(OUT port)
P = 34.5
2
17.25
L Dimension
Dimension
VCS
(mm)
n (stations)
2
3
4
5
6
7
8
9
10
L1
70
105
140
175
210
245
280
315
350
L2
82
117
152
187
222
257
292
327
362
L3
94
129
164
199
234
269
304
339
374
Manifold composition 2 stns. x 1 3 stns. x 1 2 stns. x 2 2 stns. + 3 stns. 3 stns. x 2 2 stns. x 2 + 3 stns. 2 stns. + 3 stns. x 2 3 stns. x 3 2 stns. x 2 + 3 stns. x 2
Note) Manifold base is consisted of the junction of 2 and 3 station bases.
Refer to page 252 and 253 regarding manifold additions.
251
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW10/20/30
Manifold Exploded View
Bracket assembly
Manifold base for 2 stations Passage pipe assembly
Manifold base for 3 stations
Bracket assembly
Connecting plate
assembly
Connecting plate
assembly
∗ Figure shows VV2DW2.
Manifold additions
Install a passage pipe assembly in between the manifold bases to be added.
Connect the respective manifold bases with a connecting plate assembly. (Tightening torque: 0.9 ± 0.1 N·m)
Attach brackets to the manifold bases. {when equipped with brackets} (Tightening torque: 0.9 ± 0.1 N·m)
Note) Manifold can be increased by every 2 or 3-station unit.
Order one set each of manifold base, connection plate assembly and passage pipe assembly.
252
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
2 Port Solenoid Valve for Water and Air
Series VDW10/20/30
<Manifold base>
<Connecting plate assembly>
• Series 10, 20
• Series 10, 20
VVDW 2 0
2 C
1
VVDW 2 0
01
Series
Series
1
2
1
2
10
20
Thread type
Material
C
S
Rc
G
NPT
Nil
F
N
Brass (C37)
Stainless steel
OUT port size
1
2
Stations
Symbol
For 2 stations
For 3 stations
M5
01
Port size
M5
1/8 (6A)
Note) Two sets of connecting
plate and mounting
screws.
4A
VX2
10
20
VXD
• Series 30
VXZ
VVCW20-4A
VXE
VXP
∗ Series 10 is available
with M5 only.
VVCW20 2 C
1
01
Thread type
Brass (C37)
Stainless steel
Nil
F
N
Stations
1
2
For 2 stations
For 3 stations
VXH
• Series 10, 20
VVDW 2 0
Material
C
S
VXR
<Passage pipe assembly>
• Series 30
Rc
G
NPT
6A
Material
Series
1
2
Symbol Pipe material Seal material
NBR
Nil
FKM
Brass (C37)
A
EPDM
B
NBR
G
Stainless
FKM
H
steel
EPDM
J
10
20
OUT port size
Symbol
01
02
VXF
Port size
1/8 (6A)
1/4 (8A)
• Series 30
VVCW20
<Bracket assembly>
• Series 10, 20
VVDW 2 0
Series
1
2
10
20
5A
Note) Consists of a set for D
and U sides.
VX3
VXA
VCH첸
VDW
VQ
6A
LVM
Material
Symbol Pipe material Seal material
NBR
Nil
Brass (C37)
FKM
A
EPDM
B
NBR
G
Stainless
FKM
H
steel
EPDM
J
VCA
VCB
VCL
VCS
VCW
• Series 30
VVCW20-5A
253
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
7-02-23-VDW200-300.qxd
09.10.1 1:27 PM
Page 1
Compact Direct Operated
3 Port Solenoid Valve for Water and Air
Series VDW200/300
How to Order Valves (Single Unit)
VD W 2 50 1 G
2
01
For Water, Air, Vacuum
CE compliant
Series
2
3
Nil
—
Q
CE compliant
200
300
Made to Order
(Refer to page 255.)
Valve type
C.O.
Option
N.C. N.O.
(2) (3)
50
Nil
None
F
Foot bracket
Note) The foot bracket is
packed with a valve.
(1)
IN
Material and insulation type
Voltage
Symbol
Voltage
1
2
3
4
5
6
V
S
R
100 VAC (50/60 Hz)
Grommet / Faston Grommet /
Tape
terminal,
winding (G) Molded (F) Molded (W)
Symbol
Body
material
Seal
material
NBR
Nil
24 VDC
A
B
G
H
J
12 VDC
L Note)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
6 VDC
Coil
insulation
FKM
Brass (C37)
EPDM
NBR
Stainless
steel
Class B
FKM
EPDM
FKM
Note) The armature assembly is a corrosion resistant construction.
5 VDC
3 VDC
∗ Please consult with SMC regarding other voltages.
Thread type
Coil type
G – Grommet / Tape winding
W – Grommet / Molded
Nil
Rc
F
N
NPT
G
Port size
Symbol
Port size
M5
01
02
M5
Series
200
1/8 (6A)
쑗
쑗
1/4 (8A)
—
300
—
쑗
쑗
Magnet wire protection: Tape winding Magnet wire protection: Resin Molded
F – Faston terminal / Molded
Orifice diameter
N.O.
N.C.
Symbol Orifice diameter Orifice diameter
(mm ø)
(mm ø)
Magnet wire protection: Resin Molded
1
2
2
3
4
1
1.6
Series
1
200
1.8
300
2
3
4
254
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
3 Port Solenoid Valve for Water and Air
Series VDW200/300
Standard Specifications
Valve construction
Direct operated poppet
Valve specifications
Fluid Note 2)
Water (except waste water or agricultural water), Air, Low vacuum
Withstand pressure (MPa)
2.0
Ambient temperature (°C)
–10 to 50
Fluid temperature (°C)
1 to 50 (No freezing)
Environment
Location without corrosive or explosive gases
3
Valve leakage (cm /min)
0 (with water pressure) 1 (Air)
Mounting orientation
Coil specifications
24 VDC, 12 VDC, 100 VAC, 110 VAC, 200 VAC, 220 VAC (50/60 Hz)
VXE
±10% of rated voltage
Allowable voltage fluctuation (%)
Coil insulation type
Class B
VXP
Grommet / Tape winding
Dust-proof (equivalent to IP40)
Faston terminal / Molded
Dust-tight (equivalent to IP60) Note 5)
Grommet / Molded
Dust-tight / Low jetproof (equivalent to IP65)
Power consumption (W) Note 3)
Made to
Order
VXZ
30/150
Rated voltage
Enclosure
VXD
Unrestricted
Vibration/Impact (m/s2) Note 4)
(For details, refer to page 259.)
Symbol
X22
Characteristic Specifications
Specifications
VXR
VXH
3
Note 1) Please consult with SMC when used under conditions which may cause condensation on the
exterior of the product.
Note 2) When used with deionized water, select “L” (Stainless steel, FKM) for the material type.
Note 3) Since the AC coil specification includes a rectifier element, there is no difference in power consumption between inrush and holding.
3.5 W in the case of 110/220 VAC
Note 4) Vibration resistance ····· No malfunction when tested with one sweep of 5 to 200 Hz in the axial
direction and at a right angle to the armature, in both energized and
deenergized states.
Impact resistance ········ No malfunction when tested with a drop tester in the axial direction and
at a right angle to the armature, one time each in energized and
deenergized states.
Note 5) Since electrical connections are exposed, there is no water resistance.
Made to Order
VX2
VXF
VX3
VXA
VCH첸
VDW
VQ
Non-leak (10-6 Pa·m3/sec) /
Vacuum (0.1Pa·abs) specification
LVM
X23 Oil-free specification
X60 Lead wire length: 600 mm specification
X133 Seal material: Kalrez® specification Note)
Model
Port size
Max. operating pressure
differential (MPa) Note 2)
Orifice dia.
(mm ø)
Pressure port 1 Pressure port 2, 3 Note 1)
Note) Kalrez® is a registered trademark of DuPont Dow
Elastomers.
VDW200
M5
1/8 (6A)
VDW300
1/8 (6A)
1/4 (8A)
1
0.9
0.3
1.6
0.7
0.1
2
0.8
0.2
3
0.4
0.1
4
0.2
0.05
Operating
pressure range
(MPa) Note 3)
Mass
(kg)
0.12
VCA
VCB
VCL
0 to 1.0
1/8: 0.27
1/4: 0.30
Note 1) Indicates the maximum operating pressure differential of pressure ports 2 and 3.
Note 2) The maximum operating pressure differential changes depending on the flow direction of the
fluid. Refer to page 264 for details.
Note 3) For low vacuum specifications, the operating pressure range is 1 Torr (1.33 x 102 Pa) to 1.0
MPa.
Please consult with SMC if using below 1 Torr (1.33 x 102 Pa).
VCS
VCW
Flow Characteristics
Model
Port size
Orifice dia.
(mm ø)
N.C.
VDW200
M5
1/8 (6A)
VDW300
1/8 (6A)
1/4 (8A)
1
1.6
N.O.
1
2
3
4
1.8
Water
1→2 (IN→N.C.)
–6
Av x 10 m
2
1→2 (IN→N.C.)
Cv
Cv
3
Av x 10–6 m2
converted
converted C [dm /(s·bar)]
0.72
0.03
1.9
0.08
3.8
0.16
6.7
0.28
11
Air
1→3 (IN→N.O.)
0.44
0.96
3.1
0.04
0.13
1→3 (IN→N.O.)
b
Cv
0.12
0.35
0.03
0.31
0.45
0.09
0.52
0.52
0.16
1.0
0.52
0.30
1.5
0.49
0.46
C
[dm3/(s·bar)]
b
Cv
0.13
0.52
0.04
0.38
0.50
0.12
255
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW200/300
Construction
VDW250
VDW350
i
o
!0
i
!1
o
w
!0
!1
e
r
w
e
u
r
u
t
t
y
q
y
q
Component Parts
No.
Description
Material
Standard
Option
Brass (C37)
Stainless steel
1
Body
2
Tube assembly
Stainless steel
—
3
Coil assembly
—
—
4
Armature assembly
5
O-ring (Body)
NBR
FKM, EPDM
6
Return spring
Stainless steel
—
7
Cover
SPCE
—
8
Socket
C36
Stainless steel
9
O-ring
10
Plate
11
Wave washer
Stainless steel, PPS, NBR Stainless steel, PPS, FKM, EPDM
NBR
FKM, EPDM
SPCC
—
Stainless steel
—
256
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Compact Direct Operated
3 Port Solenoid Valve for Water and Air
Series VDW200/300
Dimensions
VDW250-쏔WG
VDW350-쏔WG
36 (27.6)
22
Lead wire
l Approx. 300
M5, 1/8
27
3 (N.O.) port
4 x ø5
ø20.5
3
1
Rectifier
element
AC type
1/8, 1/4
3 (N.O.) port
25
VX2
1
30
Rectifier
element
AC type
SMC
20
SMC
2 x ø3.5
40
20
27
Lead wire
l Approx. 300
VXD
34
VXZ
ø28
VXE
VXP
71
3
VXF
M5, 1/8
VX3
8.5 (6.3)
1 (IN) port
VXA
6
15
M5, 1/8
2 (N.C.) port
VXH
86 (82.5)
5
8
1
VXR
1/8, 1/4
1 (IN) port
1/8, 1/4
2 (N.C.) port
VCH첸
Dimensions inside ( ) are for port size 1/8.
VDW
12.8
2 x M3 x 5
VQ
LVM
2 x M4 x 6
VCA
VCB
Bracket assembly part no.
쎲
Series 200
VDW20
쎲
VCL
15A 1
VCS
Series 300
VCW20
12
VCW
01A
257
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW200/300
Dimensions
VDW250-쏔F
VDW350-쏔F
14
4 x ø5
1/8, 1/4
3 (N.O.) port
36.5
9
10.5
20.5
M3.5
(for grounding)
VDW350-*F*-***-*-*
5
8
55.8
46.2
VDW250-*F*-***-*-*
86 (82.5)
71
0.8
M3.5
(for grounding)
28
0.8
14.3
9
17.5
8.5 (6.3)
29.6
6.7
SMC
2 x ø3.5
(Bracket mounting hole)
M5, 1/8
3 (N.O.) port
25
34
6.35
11.4
20
27
6.35
40
30
27
20
22
2 (N.C.) port
6
M5, 1/8
M5, 1/8
1 (IN) port
36 (27.6)
1/8, 1/4
2 (N.C.) port
1/8, 1/4
1 (IN) port
2 x M3 x 5
2 x M4 x 6
15
12.8
Bracket assembly part no.
쎲
Series 200
VDW20
쎲
15A 1
Series 300
VCW20
12
01A
258
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Made to
Order
Made to Order Specifications:
Please consult with SMC for detailed size, specifications and delivery.
Symbol
1
–6
3
Non-leak (10 Pa·m /sec) /
Vacuum (0.1 Pa·abs) Specification
VDW
Standard model no.
X22
Symbol
2
X23
Oil-free Specification
VDW
Standard model no.
X23
X22
VX2
Symbol
3
Lead Wire Length: 600 mm
Specification
VDW
Standard model no.
X60
X60
Symbol
4
Seal Material: Kalrez®
Specification
VDW
Standard model no.
X133
VXD
VXZ
VXE
X133
VXP
VXR
VXH
VXF
VX3
VXA
VCH첸
VDW
VQ
LVM
VCA
VCB
VCL
VCS
VCW
259
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Specific Product Precautions 1
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Design
Warning
1. Cannot be used as an emergency shutoff valve, etc.
The valves presented in this catalog are not designed for safety applications such as an emergency shutoff valve. If the
valves are used in this type of system, other reliable safety assurance measures should also be adopted.
2. Extended periods of continuous energization
Please consult with SMC when using with energization for
long periods of time.
3. Liquid rings
In cases with a flowing liquid, provide a by-pass valve in the
system to prevent the liquid from entering the liquid seal
circuit.
4. This solenoid valve cannot be used for explosion
proof applications.
5. Maintenance space
The installation should allow sufficient space for maintenance
activities (removal of valve, etc.).
Selection
Warning
1. Confirm the specifications.
Give careful consideration to the operating conditions such as
the application, fluid and environment, and use within the operating ranges specified in this catalog.
2. Fluid temperature
Please use within the operating fluid temperature range.
3. Fluid quality
In the case of water
The use of a fluid which contains foreign matter can cause
problems such as malfunction and seal failure by promoting
wear of the valve seat and armature, and by sticking to the sliding parts of the armature, etc. Install a suitable filter (strainer)
immediately upstream from the valve. In general, a mesh of
about 80 to 100 is a guideline for the filter.
In the case of air
Please use ordinary compressed air where a filter of 40 µm or
less is provided on the inlet side piping. (Except dry air)
Caution
1. Leakage voltage
Particularly when using a resistor in parallel with a switching
element and using a C-R element (surge voltage suppressor) to
protect the switching element, take note that leakage current
will flow through the resistor, C-R element, etc., creating a possible danger that the valve may not turn off.
Switching element
Leakage voltage
Power supply
OFF
C
R
Valve
Leakage current
AC coil
10% or less of rated voltage
DC coil
2% or less of rated voltage
2. Low temperature operation
1) The valves can be used up to an ambient temperature of
–10°C, however take measures to prevent solidification of
impurities or freezing etc.
2) When using valves for water application in cold climates,
first stop the water supply/discharge of the pump etc., and
then take measures to prevent freezing such as draining
water in pipe. When heating by steam, be careful not to expose the coil portion to steam. Also, please take measures
to prevent freezing such as heating the body.
260
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Specific Product Precautions 2
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Mounting
Warning
1. If air leakage increases or equipment does not operate properly, stop operation.
After mounting is completed, confirm that it has been done
correctly by performing a suitable function test.
2. Do not apply external force to the coil section.
When tightening is performed, apply a wrench or other tool to
the outside of the piping connection parts.
3. Do not warm the coil assembly with a heat insulator,
etc.
Piping
Caution
1. Preparation before piping
Before piping is connected, it should be thoroughly blown out
with air (flushing) or washed to remove chips, cutting oil and
other debris from inside the pipe.
2. Wrapping of pipe tape
Winding
direction
Use tape, heaters, etc., for freeze prevention on the piping and
body only. They can cause the coil to burn out.
4. Secure with brackets, except in the case of steel
piping and copper fittings.
po
se
pr
5. Avoid sources of vibration, or adjust the arm from
the body to the minimum length so that resonance
will not occur.
6. Instruction manual
The product should be mounted and operated after the instruction manual is thoroughly read and its contents are understood. Keep the instruction manual where it can be referred to
as needed.
7. Painting and coating
thr
VXP
VXH
ox
.2
VXE
VXR
Pipe tape
ap
VXD
VXZ
When connecting pipes, fittings, etc., be sure that chips from
the pipe threads and sealing material do not enter the valve.
Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.
Ex
VX2
VXF
ea
ds
3. Avoid connecting ground lines to piping, as this
may cause electric corrosion of the system.
VX3
VXA
4. Always tighten threads with the proper tightening
torque.
VCH첸
When attaching fittings to valves, tighten with the proper tightening torque shown below.
VDW
Warnings or specifications printed or labeled on the product
should not be erased, removed or covered up.
VQ
Tightening Torque for Piping
Connection threads
M5
Rc 1/8
Proper tightening torque N폷m (kgf 폷cm)
LVM
1.5 to 2 (15 to 20)
VCA
7 to 9 (70 to 90)
Rc 1/4
12 to 14 (120 to 140)
Rc 3/8
22 to 24 (220 to 240)
VCB
∗ Reference
Tightening of M5 fitting threads
After tightening by hand, tighten approximately 1/6 turn further with a
tightening tool. However, when using miniature fittings, tighten an additional
1/4 turn after tightening by hand. (In cases where there are gaskets in two
places, such as a universal elbow or universal tee, double the additional
tightening to 1/2 turn.)
VCL
VCS
VCW
5. Connection of piping to products
• When connecting piping to a product, refer to its instruction
manual to avoid mistakes regarding the supply port, etc.
• Do not apply external force to the coil when holding it to connect piping, as the tube may deform.
261
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Specific Product Precautions 3
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Wiring
Operating Environment
Caution
Warning
1. As a rule, use electrical wire with a cross sectional
area of 0.5 to 1.25 mm2 for wiring.
Furthermore, do not allow excessive force to be applied to the
lines.
1. Do not use the valves in an atmosphere having corrosive gases, chemicals, salt water, water, steam, or
where there is direct contact with any of these.
2. Do not use in explosive atmospheres.
2. Use electrical circuits which do not generate chattering in their contacts.
3. Do not use in locations subject to vibration or impact.
3. Use voltage which is within ±10% of the rated voltage.
4. Do not use in locations where radiated heat will be
received from nearby heat sources.
In cases with a DC power supply where importance is placed
on responsiveness, stay within ±5% of the rated value. The
voltage drop is the value in the lead wire section connecting
the coil.
5. Employ suitable protective measures in locations
where there is contact with water droplets, oil or
welding spatter, etc.
Maintenance
Electrical Connections
Warning
Caution
1. Perform maintenance according to the procedure in
the instruction manual.
q
Incorrect handling will cause damage or malfunction to devices or equipment.
2. Removing the product
1) Shut off the fluid supply and release the fluid pressure
in the system.
2) Shut off the power supply.
3) Dismount the product.
w
3. Low frequency operation
Lead wire color
Rated voltage
1
2
DC
Black
Red
100 VAC
Blue
Blue
200 VAC
Red
Red
Other AC
Gray
Gray
Switch valves at least once every 30 days to prevent
malfunction. Also, in order to use it under the optimum state,
conduct a regular inspection once a half year.
Caution
∗ There is no polarity for DC.
∗ Lead wire: AWG20, outside diameter of insulator 1.79
1. Filters and strainers
1) Be careful regarding clogging of filters and strainers.
2) Replace filter elements after one year of use, or earlier
if the pressure drop reaches 0.1 MPa.
3) Clean strainers when the pressure drop reaches 0.1
MPa.
4) Exhaust the drain from an air filter periodically.
Electrical Circuit
Caution
DC circuit
AC circuit
Varistor
1(
1 (+, _)
)
SOL.
2 (_, +)
Rectifier
element
2. Storage
When not using for a long time (more than approx. one month)
after use with water, thoroughly remove all moisture to prevent
rust and deterioration of rubber materials, etc.
SOL.
2(
)
262
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Specific Product Precautions 4
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Replacing the Solenoid Coils
Caution
2 port valve
3 port valve
Socket
VX2
Flat head screwdriver
VXD
Tube assembly
q
O-ring
VXZ
Plate
VXE
Clip
Press the clip in direction q
with a flat head screwdriver,
etc., and remove it from the
tube assembly groove.
VXP
Wave washer
VXR
VXH
Solenoid coil
VXF
Solenoid coil
w
Remove the cover in direction
w, and replace the solenoid
coil.
VX3
VXA
Fixed armature threads
VCH첸
VDW
VQ
LVM
VCA
Tube assembly groove
e
Center of clip
After replacing the coil, insert
the clip into the tube assembly
groove from direction e. After
inserting it into the groove,
confirm the position and condition of the clip.
OK
After removing the socket with a wrench, etc., lift off the plate,
wave washer and cover, and replace the coil assembly. After replacing the coil, first tighten the socket by hand while holding
down the plate and wave washer, and then tighten it further with
a torque of 0.8 to 1 N·m.
∗ Precautions when attaching and removing the socket
• Be careful that the O-ring installed on the bottom (plate side) of the socket
does not fall out or become chewed up, etc.
• Be sure to secure the body by wrench, etc., and tighten the socket within the
tightening torque range given above. If the torque is applied excessively,
there is a danger of damaging the threads.
VCB
VCL
VCS
VCW
NG
Inserted position
Inserted condition
263
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VDW
Specific Product Precautions 5
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Replacement Parts
쎲
Piping to 3 Port Valve N.O. Port
Solenoid coil part no.
Caution
VDW 2 0 1 C 1
1
Socket
Series
1
2
3
Nil
L1 Note)
Grommet / Tape winding
Faston terminal / Molded
Grommet / Molded
When piping to an N.O. port, be sure to perform piping work while
securing the socket by using wrench or other tool. Refer to back
page 261 for other precautions related to piping.
Voltage
1
2
3
4
5
6
V
S
R
Type
1
2
300 mm
600 mm
Note) Type L1 is optional.
Coil type
C
F
W
10, 20, 30
200, 300
100 VAC
200 VAC
110 VAC
220 VAC
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
Fluid Flow Direction
Caution
Coil Type and Voltage Combinations
Voltage
100 VAC
200 VAC
110 VAC
220 VAC
24 VDC
12 VDC
6 VDC
5 VDC
3 VDC
Grommet / Tape winding Faston terminal / Molded
Grommet / Molded
The maximum operating pressure differential differs depending
on the flow direction of the fluid. If the pressure differential at
each port exceeds the values in the table below, valve leakage
may occur.
OUT
(2)
(1)
IN
2 Port Valve
Model
Note) To have a label on the cover, enter the part number below together with the coil
part number.
AZ-T-VDW
쎲
Cover
Lead wire length
10
20, 200
30, 300
VDW10
VDW20
Valve model no. on page 243, 248, 254
VDW30
Clip part no. (2 port)
VDW 2 0 10
Orifice diameter
(mm ø)
Max. operating pressure differential
(MPa)
Pressure port 1
Pressure port 2 Note)
1
0.9
0.4
1.6
0.4
0.2
1.6
0.7
0.2
2.3
0.4
0.1
3.2
0.2
0.05
2
0.8
0.2
3
0.4
0.1
4
0.2
0.05
Note) When applying pressure from port 2, be careful to avoid vibration and impacts,
etc.
N.C. N.O.
(2) (3)
Series
2
3
쎲
10, 20
30
VDW 2 0 12A 01
Model
Series
2
3
Material
200
300
Symbol Socket material Seal material
Nil
A
B
G
H
J
L
Port size
Symbol Port size
M5
01
02
M5
1/8 (6A)
1/4 (8A)
Series
200
300
—
쑗
쑗
—
쑗
쑗
(1)
IN
3 Port Valve
Socket assembly part no. (3 port)
Brass (C37)
Stainless
steel
NBR
FKM
EPDM
NBR
FKM
EPDM
FKM
VDW200
VDW300
Orifice diameter
(mm ø)
Max. operating pressure differential
(MPa)
Pressure port 1
Pressure port 2, 3 Note 1)
1
0.9
0.3
1.6
0.7
0.1
2
0.8
0.2
3
0.4
0.1
4
0.2
0.05
Note 1) Indicates the maximum operating pressure differential of pressure ports 2
and 3.
Note 2) When the port 2 pressure is in the higher pressure side, be careful to avoid
vibration and impacts, etc.
Thread type
Nil
F
N
Rc
G
NPT
264
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
254-VDW.qxd
10.5.7 11:30 AM
Page 1
Series VDW
Specific Product Precautions 6
Be sure to read this before handling.
Refer to front matters 42 and 43 for Safety Instructions, and pages 17 to 19 for 2 Port
Solenoid Valves for Fluid Control Precautions.
Glossary
Pressure Terminology
Other
1. Maximum operating pressure differential
1. Material
This indicates the maximum pressure differential (inlet and
outlet pressure differential) which can be allowed for operation
with the valve closed or open. When the outlet pressure is 0
MPa, this becomes the maximum operating pressure.
2. Maximum operating pressure
This indicates the limit of pressure that can be applied inside
the pipelines. (Line pressure)
(The pressure differential of the solenoid valve unit must be no
more than the maximum operating pressure differential.)
3. Withstand pressure
VX2
NBR:
FKM:
Nitrile rubber
Fluoro rubber = FPM — Trade name: Viton®,
DAI-EL™, etc.
EPDM: Ethylene propylene rubber = EPR
C37: Brass
SUS: Stainless steel
VXD
VXZ
VXE
Faston Terminal
VXP
TM
The pressure which must be withstood without a drop in performance after returning to the operating pressure range (The
value under the prescribed conditions).
1. Faston is a trademark of Tyco Electronics Corp.
VXR
2. For electrical connection of the Faston terminal and
molded coil, please use Tyco’s “Amp/Faston connector/250 Series” or the equivalent.
VXH
3. When providing a body ground, please use the
frame ground (M3.5).
Electrical Terminology
1. Surge voltage
(Recommended fastening bolt: M3.5, length 5 mm)
A high voltage which is momentarily generated in the shut-off
unit by shutting off the power.
VXF
VX3
VXA
2. Enclosure
VCH첸
A degree of protection defined in the “JIS C 0920: Waterproof
test of electric machinery/appliance and the degree of protection against the intrusion of solid foreign objects”.
VDW
Verify the degree of protection for each product.
VQ
IP
LVM
Second characteristic numeral
VCA
First characteristic numeral
VCB
쎲 First Characteristics:
Degrees of protection against solid foreign objects
0
1
2
3
4
5
6
VCL
Non-protected
Protected against solid foreign objects of 50 mm ø and greater
Protected against solid foreign objects of 12 mm ø and greater
Protected against solid foreign objects of 2.5 mm ø and greater
Protected against solid foreign objects of 1.0 mm ø and greater
Dust-protected
Dusttight
VCS
VCW
쎲 Second Characteristics:
Degrees of protection against water
0
1
2
3
4
5
6
7
8
Non-protected
Protected against vertically falling water drops
Protected against vertically falling water drops when enclosure tilted up to 15°
Protected against rainfall when enclosure tilted up to 60°
Protected against splashing water
Protected against water jets
Protected against powerful water jets
Protected against the effects of temporary immersion in water
Protected against the effects of continuous immersion in water
—
Dripproof type 1
Dripproof type 2
Rainproof type
Splashproof type
Low jetproof type
Strong jetproof type
Immersible type
Submersible type
Example) IP65: Dusttight, Low jetproof type
“Low jetproof type” means that no water intrudes inside an
equipment that could hinder from operating normally by
means of applying water for 3 minutes in the prescribed
manner. Take appropriate protection measures, since a
device is not usable in an environment where a droplet of
water is splashed constantly.
265
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF