Siqura HSD622 Quick start manual
Siqura HSD622 is an IP PTZ dome camera with day/night and wide dynamic range capabilities, designed for outdoor and indoor surveillance. It features a 22x optical zoom lens, 360° continuous pan, and 90° tilt for comprehensive coverage. The HSD622 supports H.264 and MJPEG video compression, allowing for efficient bandwidth utilization and high-quality video streaming. Additionally, it has built-in audio input and output for two-way communication and alarm input and output for integration with external security systems.
Advertisement
Advertisement
Siqura HSD620/622/626 & MSD620/622
IP PTZ dome with day/night and wide dynamic range
Quick Start Guide
Package contents
Figure 1 Outdoor camera package contents
Outdoor model with tube adapter
Waterproof
boot
CD (Manuals and software)
Quick Start
Guide
Optical
cover
Cable
harness
Instruction leaflets
SFP
Accessory
HSD models only
Indoor model
Figure 2 Indoor camera package contents
Outdoor camera mounting requirements
Use one of two types of mounts to install an outdoor HSD62x/MSD62x on a wall.
Siqura WM01A Mini Wall Mount
Siqura WM07 Long Wall Mount
Figure 7 WM01A Mini Wall Mount
Security torx
Screws
(M3, M5 PH, M5 torx)
Lubricant
Figure 8 WM07 Long Wall Mount
The mini wall mount and the long wall mount can be installed onto a box mount if extra space for the cables is required.
Outdoor installation requires the following items:
Dome camera
Supplied waterproof boot
Wall mount (optional accessory)
Screws and screw anchors
Screwdriver and drill
Cabling overview
For operation, an HSD62x/MSD62x camera requires the following:
A Cat 5 Ethernet cable with an RJ-45 connector
- or (for /SFP models) -
An SFP module as described in the XSNet™ SFP data sheet and fiber optic cable and connectors compatible with the chosen SFP module.
A cable harness for power, analogue video, and audio transmissions, equipped with a 22-pin connector for connecting to the camera (table 1).
Figure 3 Cable harness components
24 VAC
Ground (GND)
24 VAC
Figure 4 Power input details Figure 5 22-pin connector pins
RJ-45 connector LEDs
Green indicates a good network connection.
Yellow verifies network activity.
Figure 6 RJ-45 connector LEDs
Prepare outdoor camera for installation
To prepare the outdoor HSD62x/MSD62x for installation
1. Remove the outdoor tube adaptor by rotating counter clockwise (figure 9a).
2.
3.
4.
Make a note of the IP address on the label attached to the cylindrical heat sink.
Remove the PE cloth and take off the lens cap.
Generously apply the supplied lubricant to the optical cover’s waterproof boot to ensure an IP66 quality installation (figure 9b).
5.
6.
Loosen the screw head alignment pins on the dome cover by turning clockwise and line up the alignment pin and screws on the optical cover with the holes in the dome body.
Attach the optical cover to the dome body by pressing gently down on the sides of the dome cover (figure 9c).
7. Turn the screw head alignment pins counter-clockwise with a suitable screwdriver to lock the dome into place and secure the dome with the included
Phillips-head or torx screw.
© Siqura B.V. 2014
Version 2.0 (101310-2) xSD62x QSG (MW10)
Figure 9a
Remove outdoor tube adapter
Figure 9b
Lubricate optical cover’s waterproof boot
www.siqura.com www.tkhsecurity-usa.com
Figure 9c
Attach optical cover to dome body
22-Pin connector definition
Pin Definition
1
2
AC 24-1/DC(+)
Alarm out, NC
14
15
16
17
10
11
12
13
18
19
20
21
22
7
8
9
3
4
5
6
AC 24-2/DC(-)
Alarm out, NO
FG
Alarm out, COM
Audio in
Audio out
Audio GND
Audio GND
Isolated GND
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Alarm 5
Alarm 6
Alarm 7
Alarm 8
Alarm GND
Video GND
Video
Cable
20/18 AWG
20/18 AWG
20/18 AWG
24 AWG
Colour
Red
White
Black
White/black
Yellow
Green/black
Yellow/black
Orange/black
Green/black
Brown/black
Blue/white
Red/white
Purple
Gray
Blue
White/black
Orange/black
Rating
Photo Relay output 300 V
Photo Relay output 300 V
Photo Relay output 300 V
Input 5 V 10 kΩ pull up
Photo Relay output 300V
Purple/white
Gray/black
Brown/white Input 5 V 10 kΩ pull up
Black/gray
20 AWG
Red/gray
Table 1 22-pin connector assignments
2.
3.
4.
5.
6.
7.
8.
9.
Install outdoor camera with wall mount
To mount the outdoor HSD62x/MSD62x with a wall mount
1. Make a hole in the wall or metal access plate for the cables and secure the supplied cable gland in the wall.
Ensure that the weather resistant gasket is correctly attached to the mount.
Thread the cables through the wall mount and screw it onto the wall.
Attach the waterproof boot to the wall mount.
Thread the cables through the outdoor tube adaptor and fix it to the wall mount with the supplied screws and washers.
Clip the safety wire to the dome camera.
To keep insects out, block the cable entry hole with the supplied sponge.
Connect the cables to the dome camera.
Attach the dome to the outdoor tube adaptor and fasten them together with the supplied screws.
Figure 10 Long wall mount Figure 11 Mini wall mount
Warning: Fully torque down the mounting bolt that attaches the
WM02 tube adapter to the mounting bracket to prevent any movement of the camera due to wind, vibration, etc.
Make sure the camera cannot move at all in its bracket after installation. Any movement of the camera in its bracket can compromise positional accuracy.
Indoor camera mounting requirements
Indoor installation requires the following items:
Dome camera
CM04 Flush Mount (optional accessory)
Decorative ring (supplied with flush mount)
Screw (supplied with flush mount)
Red sticker (supplied with flush mount)
Tool for cutting a circular hole in the ceiling
Screwdrivers (slotted and Phillips)
Figure 12 In-ceiling mounting
Install indoor camera with flush mount
To mount the HSD620/MSD620 with a flush mount
1. Detach the removable wing from the flush mount
2.
(figure 13a).
With the supplied screw, attach the separated wing to the dome body (figure 13b).
3.
4.
5.
6.
Place the red sticker on the ceiling and cut the circle out of the ceiling.
Insert the flush mount into the hole.
Rotate the flush mount’s wings to fix the mount at the edge of the ceiling opening and tighten their screws
(figure 13c).
Thread the cable harness and Ethernet cable through the centre hole of the flush mount and connect them to
7.
8. the dome body.
Mount the dome body into the bracket and rotate clockwise (figure 13d).
Tighten the fixing screw, to secure the dome body
(figure 13e).
9. Detach the optical cover, if necessary, and attach the decorative ring to the mount.
10. Reattach the optical cover.
Figure 13a
Figure 13b
Install Siqura Device Manager
Figure 14
Install Siqura Device
Manager from Siqura
Product CD
Note: Insert a ceiling panel prior to installing the dome camera to reinforce the ceiling's strength, if necessary. A ceiling panel may be needed, for example, when installing the dome camera in a suspended ceiling.
Access the camera via Siqura Device Manager
10.0.0.0/8
HSD626
1 2
Figure 13c Figure 13d Figure 13e
Log on to the camera webpages
To log on to the camera
1.
2.
On the Login page, click LOGIN.
Log on with the account that was created for you.
User name and password are case sensitive.
The factory-set user name is "Admin" with password "1234" (figure 16a).
3.
Note: To prevent unauthorised access from people using the default account, we recommend that the administrator changes the default password after first login and creates separate user accounts as needed. This also removes the default account details from the login screen (figure 16b).
Click OK or press ENTER.
On successful login, the Live Video page appears.
Figure 16a Access with default Admin account only
Figure 15 Camera detected by Siqura Device Manager
View video stream in video player (VLC)
Figure 17
Video stream from camera opened and viewed in VLC Media
Player
Figure 16b Access with user account created by Admin
Important: Log on as “admin” with an empty password if the firmware version of the camera server board is lower than v4.0. rtsp://10.0.231.156/VideoInput/1/h264/1 camera IP address video input number media type video encoder number

Public link updated
The public link to your chat has been updated.
Advertisement