Nexans Cabling Solutions Catalogus (wordt in een nieuw venster geopend)

Nexans Cabling Solutions Catalogus (wordt in een nieuw venster geopend)
Nexans Cabling Solutions
LAN Systems
Energy Efficient Datacentres
Next-generation solutions from Nexans
Data centre managers face
common challenges - to keep
information flowing reliability,
to plan for future migration and
to manage energy consumption.
Nexans can help meet these challenges with
reliable infrastructure solutions which offer
a migration path to 40G whilst delivering
the maximum potential for energy efficiency.
Nexans Cabling Solutions
Alsembergsesteenweg 2, b3
B - 1501 Buizingen
Tel: +32 2 363 38 00 • [email protected]
www.nexans.com/LANsystems
With Environmental Monitoring and Access
Control (EMAC) and LANsense Intelligent
Infrastructure Management, Nexans offer
complete infrastructure solutions for data centres.
Global expert in cables
and cabling systems
Table of content
Nexans
7
Symbols
8
LANsystems Introduction
9
LAN Cabling Systems
20
Copper
21
Category 5e
22
LANmark-5 Cable
23
LANmark-5 Snap-In connector
26
LANmark-5 Patch Panels
28
LANmark-5 Outlet 45x45
30
LANmark-5 UniBoot Patch Cords
32
Essential Cat 5e Cable
35
Essential Snap-In Connector
38
Essential-5 Keystone Connector
40
Essential Patch Panels
42
Essential Outlet Modules
44
Essential Cat 5e Patch Cords
46
Category 6 / 6A
48
LANmark-6 Cable
49
LANmark-6 Snap-In Connector
52
LANmark-6 UniBoot Patch Cords
54
LANmark-6 10G UniBoot Patch Cords
56
LANmark-6 10G Snap-In Connector
58
LANmark-6A Cable
61
LANmark-6A Connector
63
LANmark-6A Ultim UniBoot Patch Cords
66
Essential-6 Cable
69
Essential-6 Keystone Connector
71
Essential-6 Patch Panels
73
Essential-6 Outlet Modules
75
Essential-6 Patch Cords
77
03/12/10 - http://www.nexans.co.uk
Page 2 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Category 7 / 7A
80
LANmark-7 Cable
81
LANmark-7 GG45 Connector
83
GG45 8C PCB jack
85
LANmark-7 Patch Cords
87
LANmark-7 Splitter Cords
89
LANmark-7A Cable
91
LANmark-7A GG45 Connector
92
LANmark-7A Patch Cord
95
Modular Patch Panels
97
Modular Patch Panels for Snap-In Connectors
98
Empty Patch Panels for Keystone Connectors
100
Modular Outlets
102
European Mounting Hardware for LANmark
103
UK Mounting Hardware for Essential
104
UK Mounting Hardware for LANmark
106
US Mounting Hardware for LANmark
108
3rd Party Party Compatible Mounting Hardware
110
European Mounting Hardware for Essential Keystone
112
US Mounting Hardware for Essential
114
Voice grade
116
Voice Cables
117
IDC connectivity and accessories
119
Voice Patch Panels
121
Voice Patch Cords
123
Tools & Accessories
125
Tools
126
Keystone Clips
128
Retrot Hoods
130
Pre-terminated Copper
132
LANmark Pre-Term Bundles
133
LANmark Pre-Term Units
135
LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack
137
03/12/10 - http://www.nexans.co.uk
Page 3 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Optical Fibre
141
Fibre Cables
142
Optical cable specications
143
LANmark-OF Tight Buffer Indoor
146
LANmark-OF Tight Buffer Universal
149
LANmark-OF Micro-Bundle Indoor
151
LANmark-OF Micro-Bundle Universal (24F-72F)
154
LANmark-OF Micro-Bundle Universal (4F-12F)
157
LANmark-OF UD PE
159
LANmark-OF UC PE
162
LANmark-OF UC LSZH
164
Cables - LANmark-OF ZC LSZH
166
Fibre Connectors & Connector Accessories
168
LANmark-OF Connectors
169
Connector Tools & Accessories
170
Pre-Terminated Fibre Assemblies
LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly
MPO System
172
173
177
LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2, OM3 and OM4
179
LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2), OM3 and OM4
182
LANmark-OF Plug&Play Patch Panels
185
LANmark-OF [email protected] Module
186
Fibre Patch Panels
188
LANmark-OF Sliding Patch Panels
189
LANmark-OF Sliding Preloaded Patch Panels
191
Essential-OF Fixed Patch Panel
194
Outlets
196
LANmark-OF Zone Distribution box
197
Structural Hardware
199
Patch Cords
201
LANmark-OF Patch Cords
Pigtails & Splicing Materials
202
207
LANmark-OF Splicing Accessories with Aluminium Protectors Preloaded Sliding Panel
03/12/10 - http://www.nexans.co.uk
208
Page 4 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
LANmark-OF Splicing Accessories with Aluminium Protectors Snap-In Panel
211
LANmark-OF Splicing Accessories with Heatshrink Protectors Preloaded Sliding Panel
214
LANmark-OF Splicing Accessories with Heatshrink Protectors Snap-In Patch Panel
217
Splicing Materials & Accessories
220
LANmark-OF Pigtails Maxistrip
222
LANmark-OF Pigtails Tight Buffer
224
Adaptors
226
LANmark-OF Snap-In Adapter
227
Standard Adaptors
229
Tools & Accessories
231
LANmark-OF Cleaning Tools
232
LANmark-OF Fibre Accessories
233
Intelligent Infrastructure Management
235
LANsense Software
236
LANsense EMAC Products
237
LANsense Copper Patch Panels
240
LANsense Copper Patch Cords
242
LANsense Fibre Patch Panels
244
LANsense Fibre Patch Cords
246
LANsense Analysers
248
LANsense Next Generation Analyser
250
LANsense I/O and Master/Link cables
252
LANsense Integration Strips
254
Industrial LAN & Harsh Environments
255
LANmark Industry Copper cables
256
LANmark Industry Optical Fibre cables
258
LANmark Industry DIN-Rail Outlets and boxes
260
LANmark Industry IP65/67 outlets
261
LANmark Industry patch cord RJ45 IP67/IP20 Cat.6
263
General Accessories & Cabinets
265
Datacenter racks and frames
266
Patch Guides, Blank Panels & Cable Management
268
LANmark Zone Distribution Boxes
270
03/12/10 - http://www.nexans.co.uk
Page 5 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Cabinets - Quick Mount
272
Cabinets - Wall Mountable
274
Cabinet Accessories
276
Miscellaneous Accessories
278
Software, Training, & Services
280
Warranty Services
281
Network Design Tools
282
Training Services
284
03/12/10 - http://www.nexans.co.uk
Page 6 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Nexans
Nexans is the worldwide leader in the cable industry
With energy as the basis of its development, Nexans is a global player in the infrastructure, industry, building and Local
Area Network (LAN) markets.
As a worldwide leader in the cable industry, it offers an extensive range of cables and cabling systems to raise industrial
productivity, improve business performance, enhance security, enrich the quality of life, and assure long-term
network reliability.
With an industrial presence in 39 countries and commercial activities worldwide, Nexans employs 22,700 people and had
sales in 2009 of 5 billion euros. Nexans is listed on NYSE Euronext Paris, compartment A. More information on
www.nexans.co.uk
Infrastructure
Nexans provides complete cables and cabling solutions for power transmission and distribution. New technologies,
which are environmentally-friendly, increase capacity and reduce the danger of blackouts.
To reinforce rail safety and efciency, we have products especially designed for the demanding railroad environment.
And to meet diverse needs of incumbent and new telecoms operators, Nexans has customized solutions aimed at lowering
capital expenditure and operating costs.
For the world’s busy airports, we offer cables and cabling systems for energy and communication networks, terminals,
baggage handling systems, runway lights, control towers, etc.
Industry
Nexans offers a complete portfolio of cables and solutions for market segments as diverse as the automotive, rolling
stock and aerospace industries, shipbuilding, nuclear power, oil & gas and petrochemicals, medical and wind
applications, material handling and automation.
We add value through advanced technologies and durable high-performance products.
Building
Nexans supplies cables and network solutions for structures of all types: from small residences to public and ofce buildings
and big industrial complexes.
Nexans pioneered fire-performance cables for public safety, created industrial Ethernet solutions to unite the ofce and
the factory oor platform, and ensured the highest standards of environmental friendliness and recyclability.
From standard products to renewable energy solutions, these products contribute to the substainable buildings of the future.
Local Area Networks
Nexans provides copper and optical ber cabling systems for new resource-intensive applications, like Data Centers,
Security services, and Storage Area Networks.
Nexans’ advanced solutions are handling core business data, protecting operations in sensitive conditions, and giving
organizations highspeed transmission and the ability to protect and retrieve vital information.
03/12/10 - http://www.nexans.co.uk
Page 7 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Symbols
Minimum dynamic operating bending radius
Operating temperature, range
RoHS conform
Storage temperature, range
Ambient installation temperature, range
Fire retardant
Mechanical resistance to impacts
Flame retardant
Minimum static operating bending radius
03/12/10 - http://www.nexans.co.uk
Page 8 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
LANsystems Introduction
Introduction
Modern structured cabling systems for Local Area Networks (LANs) are in demand wherever data is stored, shared or
transferred. LAN cabling systems are considered permanent infrastructure of single or multiple buildings, and therefore
must comply with current standards regarding system architecture and channel bandwidth, as well as installation.
LAN system connections are arranged using modern high-capacity components, and designed to be adaptable to meet
today’s bandwidth needs as well as evolving, higher bandwidth applications of the future. Also, LAN topology and
architecture should be sufciently exible to easily support the ongoing movement of employees and entire departments.
LAN system needs explained
LANs need to provide the following benets:
• high capacity communication lines to facilitate a rapid response to growth in a company’s data requirements; growth;
• ability to support a wide range of network applications, depending on the System Class, by using standards for data
transfer, channel length and connection interfaces;
• well-developed and exible architecture allowing various network congurations to support new LAN equipment;
• ability to increase the number of nodes using the cabling system’s reserves planned for at the design stage;
• reliability offered by resilient backbones, which allow bypassing of damaged network segments;
• high performance, allowing long-term use of the system with easy migration paths
How Nexans addresses LAN needs
Nexans Cabling Solutions (NCS) provides exceptional infrastructure design, products, maintenance and support for LANs
worldwide. Nexans’ products set the standards in their class. The company constantly improves its products and
technologies at its own research facility, aided by professionals in the eld of data transfer systems and solutions.
Every Nexans’ LAN component meets all current standards, yet at the same time, are unique creations in design, features
and customer advantages. The company is among the world leaders in the telecommunications equipment market.
Automated assembly processes for the most sensitive cable communication equipment ensure high quality installation. And
superior line and channel properties help ensure a level of reliability exemplied by a 25-year warranty on applications and
component quality. Ofcial Certied System Partners also offer a highly competitive labour-cost warranty.
LAN Standards
International LAN standards
One of the principal international documents dening LANs is ISO/IEC 11801. This is a joint standard by the International
Standards Organisation (ISO) and the International Electrotechnical Commission (IEC),. ISO/IEC 11801 sets a standard for
structured cabling systems installed in customers’ buildings and premises. The requirements apply primarily to
administrative or commercial structures. In modern ofce facilities, however, it is typical to exchange data with a warehouse
or production facility, and the recommendations in ISO/IEC 11801 cover such applications as well.
The standard denes the main characteristics of cabling systems including its architecture, cables and connectors, cable
parameters, as well as the length and bandwidth of links and channels.
In order to understand the principles of selecting and using cabling systems for transferring data, voice, video or any other
information, it is important to read the standards and recommendations in the September, 2002, edition of ISO/IEC 11801,
as well as the amendments of 2010. This section provides a brief overview of these requirements as applied to the products
in this catalogue.
LAN Topology and Architecture
The basis of LAN topology is depicted by the master-slave star architecture, also known as ‘tree’ topology. Junctions in such
architecture are the distributors, and connecting and/or switching equipment supporting various distribution roles.
03/12/10 - http://www.nexans.co.uk
Page 9 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Fig. 1. Hierarchy of a typical LAN cabling system.
CD – Campus Distributor
BD - Building Distributor
FD – Floor Distributor
CP – Consolidation Point
TO – Telecommunications Outlet
Structured cabling connects switches, , computers and increasingly, devices like telephones and IP cameras. LANs should
therefore have a high degree of exibility to support widely diverse connections as well as the ability to respond promptly to
changeable requirements for the physical channel conguration.
Distributors
Patch panels are mounted on racks or in cabinets, and can also be installed beneath oors or behind walls. Normally, the
cabinets also house power supply units and various accessories facilitating labels and administration. The cabling system
distributors are usually installed in separate technical rooms.
A LAN serving a multi-storey building may have split backbones, each one independent but still forming a star hierarchy.
Should the need arise, its communication lines can be directly connected to another backbone. It is possible to reduce the
number of backbone links and distributors depending on available space and the number of users. Certain distributors of
various levels can also be combined into one. In order to improve the system’s reliability, distributors of one level, together
with connected lines, can be replicated in various parts of the building. In this case, the user’s telecommunication outlets will
be connected to separate distributors.
03/12/10 - http://www.nexans.co.uk
Page 10 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Fig. 2. Hierarchy of a typical LAN cabling system.
BD1,2 - Building Distributor
FD1,2 – Floor Distributor
TO – Telecommunications Outlet
In cases where two or more buildings are connected using a single cabling infrastructure, the LAN will have three sections:
campus backbone, building backbone, and horizontal cabling (Fig.3).
Fig. 3. Hierarchy of a typical LAN cabling system.
CD – Campus Distributor
BD - Building Distributor
FD – Floor Distributor
CP – Consolidation Point
TO – Telecommunications Outlet
TE – Terminal Equipment
03/12/10 - http://www.nexans.co.uk
Page 11 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Backbones
The Campus backbone connects the Campus distributor with the Building distributors through panels and switches, to
which the cables are connected; and patch cords or jumpers. ISO/IEC 11801 provides for entry points to the backbone
which facilitate the entry and termination of cables inside the building. These include cables supporting telephone, Internet,
cable TV, or technical monitoring systems.
The campus distributor can be housed in the same structure as the building distributor, or even in the same technical room
as the oor distributor. Such technical rooms are called equipment rooms, and its respective requirements are set out by
ISO/IEC TR 14763-2 (Fig.4).
The building (or vertical) backbone connects separate oor distributors to the building distributor. The building backbone
consists of internal trunk cables, patch panels and patch cords for connections within the building distributor.
Horizontal cabling (or oor-by-oor distribution)) connects the oor distributor with desktop or telecommunication outlets
(TO’s). A consolidation point can also be part of the horizontal cabling in cases of zonal distribution.
Fig. 4. Location of distributors in a typical cabling system within a building.
CD- Campus Distributor
BD – Building Distributor
FD – Floor Distributor
CP – Consolidation Point
TO – Telecommunication Outlet
ER – Equipment Room
BEF – Building Entrance Facility
Cross- and direct-connect explained
The connection between active equipment and backbone or horizontal cables can be build with a degree of exibility. The
most exible solution is the cross-connect (see Fig.5).
In addition to improving system administration, this solution allows the splitting of specialists’ areas of responsibility and
facilitates equipment maintenance. However, adding connectors to the communication channel can impair its
characteristics.
The alternative to a cross-connect is an interconnect (Fig.6 - next page.)
03/12/10 - http://www.nexans.co.uk
Page 12 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Fig. 5. Example of cross-connect type
TE – Telecommunications Equipment
PP – Patch Panel
EC – Equipment Cord
PC – Patch Cord
In addition to backbones, the standard species connections to the desktop or Work Area.
ISO/IEC TR 14763-2 requires up to 10m2 for the Work Area, i.e. where the end-user equipment is connected to the
telecommunication outlets. In certain cases, the Work Area can be organised more compactly, providing 4-6 m2 per user.
According to ISO/IEC 11801, at least two telecommunication outlets must be provided for each user.
Fig. 6. Example of interconnect type
TE – Telecommunications Equipment
PP – Patch Panel
EC – Equipment Cord
PC – Patch Cord
The number of Floor Distributors (FD) depends on the area to be covered or the number of workplaces per area. Generally,
the standard recommends at least one FD for every 1 000 m2 of ofce area.
03/12/10 - http://www.nexans.co.uk
Page 13 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
The physical length of a horizontal copper channel is maximized to 100 m. The total length of sections including backbones
should not exceed 2 000 m.
Designing LANs for high speed
Supporting high speed protocols such as Fast Ethernet, 100Base-TX and Gigabit Ethernet 1000Base-T requires a minimum
of Class D performance. In order to meet Class D requirements, the components of Cat. 5e cabling should adhere to
specications of the second edition of the ISO/IEC 11801 standard, issued in 2002. As an alternative, installing Class E, Ea,
F and Fa systems within a horizontal cabling are permissible: these require components of Cat. 6, 6A, 7 and 7A
respectively. These solutions provide a high bandwidth reserve for future applications.
Nexans Cabling Solutions offers LANmark-5, 6, 6A , 7 and 7A systems. Detailed product information for these systems can
be found in this catalogue’s respective sections.
Fig. 7. The use of transfer medium in a typical LAN cabling system.
CD – Campus Distributor
BD – Building Distributor
FD – Floor Distributor
CP – Consolidation Point
TO – Telecommunication Outlet
TE – Terminal Equipment
OE EQP – Opto-electronic equipment
03/12/10 - http://www.nexans.co.uk
Page 14 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
The most important general requirements of ISO/IEC 11801:2002 for twisted pair media are:
• Cables used for Class D, E, Ea, F and Fa systems must have rated characteristic impedance of 100 Ohms;
• Connectors at the ‘TO’ side must correspond to connector standard RJ45 (IEC 60603-7) for Cat. 5e, 6 and 6A, and to
connector standard GG45 (IEC 60603-7-7) for Cat. 7 and 7A.
Fibre optic cabling applications
The standard recommends bre optic cable for campus -and building backbones. Its’ low signal attenuation, immunity to
electromagnetic disturbances and galvanic seperation between buildings make bre a strong alternative. The core of bre
optic cables, can be produced from multi-mode (MM) bres sized 50/125 mm and 62.5/125 mm with graded index prole,
and single-mode (SM) bres sized 9/125 mm with step index prole. Detailed information on Nexans bre optic cable
specications is in the section “LANmark-OF Optical Systems”.
The standard further recommends the SC- and LC-connectivity as the optical bre connector interface for all LAN
backbones. However, if a higher concentration of connections is required, the standard permits Small Form Factor
connectors (SFF) which requires LC connectors.
Design Considerations
Layouts of Horizontal Channels
The standard allows the use of four channel types within a horizontal distribution to connect user equipment as well as
network telecom equipment (see structure below.)
The simplest channel type is shown in Layout A (Fig. 8). The most exible and complex channel type in a horizontal
distribution is shown in Layout D.
Horizontal channel links have the following limitations:
• Physical length of the channel must not exceed 100 m;
• Physical length of horizontal cable used to build a communication line must not exceed 90 m, depending on the total
length of patch cords;
• If total length of patch and equipment cords exceeds 10 m, the length of the horizontal cable must be proportionally
reduced according to the algorithm detailed in the standard;
• When using a Consolidation Point (CP) for zonal distribution, it must be installed at least 15 m from the Floor
Distributor (FD).
Besides these limitations, the following recommendations for the horizontal backbone should be noted:
• When using a Multi-User Telecommunication Outlet (MUTO), the length of the equipment cord connecting the
terminal equipment should not exceed 20 m;
• Recommended length of patch cords is up to 5 m.
These recommendations allow the use of longer cords should the need arise.
03/12/10 - http://www.nexans.co.uk
Page 15 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Layout A: Interconnect-TO type
Layout B: Crossconnect-TO type
03/12/10 - http://www.nexans.co.uk
Page 16 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Layout C: Interconnect-CP-TO type
Layout D: Crossconnect-CP-TO type
Fig. 8. Possible layouts of horizontal backbone channels
BD – Building Distributors
FD – Floor Distributor
CP – Consolidation Point
TO – Telecommunication Outlet
TE – Terminal Equipment
PC – Patch Cord
EC – Equipment Cord
CC – Consolidation Point Cable
03/12/10 - http://www.nexans.co.uk
Page 17 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
If a twisted pair based system is used, the most complex and exible layout is a 4-connector channel (Fig. 9).
The principal limitations for Class D, E, Ea, F and Fa backbone communication channels are:
• Physical length of the channel must not exceed 100 m;
• When using 3 connectors along the channel, the installation or mounting cable must be at least 15 m long.
Depending on the total length of patch cords, the mounting cable’s length must be proportionally decreased. To calculate
mounting cable length, remember to account for patch and equipment cord length, as well as the category of components
and the required channel class. ISO/IEC 11801 provides calculation algorithms
Fig. 9. Typical layout of communication backbone channel.
CD – Campus Distributor
BD – Building Distributor
FD – Floor Distributor
PP – Patch Panel
EQP – Equipment
Layouts of Fibre Optic-Based Channels
Due to low signal attenuation when using bre optics, it is possible to connect the communication lines of different
backbones in a single transmission channel. The following types of combined bre channels are possible:
• Patched channel allowing cross-connection of lines belonging to different, adjoining backbones (Fig. 10);
• Collapsed backbone model creating a direct link between BD and TO limited to a distance of 300m and only with MM
bre.
03/12/10 - http://www.nexans.co.uk
Page 18 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Fig. 10. Patched combined channel layout.
BD – Building Distributors
FD – Floor Distributor
PP – Patch Panel
TO – Telecommunication Outlet
EQP - Equipment
CC - Consolidation Point Cable
TE - Terminal Equipment
03/12/10 - http://www.nexans.co.uk
Page 19 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LAN Cabling Systems
Nexans provide a full range of LAN cabling solutions & services.
• LANsense : Intelligent Infrastructure Management (IIM) including EMAC
Environmental Monitoring & Access Control
• LANmark : Passive LAN infrastructure solutions
• essential: component based cabling products
• Software, Services & Support Tools
Please see the link to LAN Systems Main webpages for support documentation
and tools.
03/12/10 - http://www.nexans.co.uk
Page 20 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Copper
Nexans offer the full range of copper LAN systems to ensure we can provide the
solution most suited for your needs.
•
•
•
•
All performance levels: Cat 5e, Cat 6, Cat 7 & voice grade
All construction types : UTP, FTP, S-FTP, PiMF
Modular connectivity based on 'Snap-in' and '808' connectivity
Guaranteed Application support with extended distance
03/12/10 - http://www.nexans.co.uk
Page 21 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Category 5e
Nexans offer a choice of Category 5e ranges:
Full System Offer
LANmark-5
• Cat 5e system based on snap-in format connectivity
LANconnect-5
• Cat 5e system based on 808 style connectivity. Extended distance support is
possible using 'LANconnect PLUS' cables.
All complete systems offer a comprehensive Certied System Parts & LABOUR
Warranty.
Component based solution
Essential - component based 'economy without compromise'
• cost effective solution for basic installations
• instant downloadable Nexans Link Certicate.
03/12/10 - http://www.nexans.co.uk
Page 22 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Cable
• Offers headroom to Category 5e standards
• Performance guaranteed to 155MHz
• Supports Gigabit Ethernet
Description
Application
Nexans LANconnect/LANmark-5 cable is designed to provide additional
performance and bandwidth over and above the basic requirements of Category
5e. With modern high speed applications, installation effects can have a serious
inuence on the initial cable performance and therefore without sufcient
headroom, problems can arise. The addition of transition points within the link can
also lead to additional losses. Nexans LANconnect/LANmark-5 provides the
additional headroom necessary to ensure that applications such as Gigabit
Ethernet can run efciently after installation. It is available in Grey PVC or Orange
LSZH.
Performance
With guaranteed performance to 155MHz, Nexans LANconnect/LANmark-5
cables provide guaranteed additional headroom and bandwidth over and above
the requirements of TIA 568-B and IEC 61156-5.
Guarantees
Nexans LANconnect/LANmark-5 cables are covered by the guarantee that they
are Category 5e and by a parts and labour warranty as described in the Nexans
Certied System Warranty. Moreover they come with following guarantees:
•
•
•
•
•
3dB min. headroom over IEC 61156-5 and TIA 568-B Cat 5e NEXT
Improved ACR
Superior EMC performance
155MHz guaranteed performance
When used in a full LANmark system, full LANmark D channel warranty can be
obtained.
Standards
International ISO/IEC 11801; ISO/
IEC 61156-5
National TIA/EIA-568-B.2
RoHS conform
Yes
03/12/10 - http://www.nexans.co.uk
Page 23 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Cable
Characteristics
Electrical characteristics
Transfer impedance
Characteristic impedance
Transmission characteristics
Propagation delay, max. 100 MHz
Usage characteristics
Range
RoHS conform
Product List
Nexans
ref.
N100.403
N100.413
N100.402
N100.421
N100.412
N100.431
N100.493
N100.443
N100.492
N100.491
N100.494
N100.442
N100.441
N100.444
N100.502
N100.507
N100.521
N100.512
N100.517
N100.522
20
100 Ohm
536 ns/100m
LANmark-5
Yes
Name
LANconnect/LANmark-5 F²/UTP Dual LSZH
500m Reel
LANconnect/LANmark-5 F²/UTP Dual PVC 500m
Reel
LANconnect/LANmark-5 F²/UTP LSZH 1000m
Reel
LANconnect/LANmark-5 F²/UTP LSZH 500m
Reel
LANconnect/LANmark-5 F²/UTP PVC 1000m
Reel
LANconnect/LANmark-5 F²/UTP PVC 500m Reel
LANconnect/LANmark-5 F¹/UTP Dual LSZH
500m Reel
LANconnect/LANmark-5 F¹/UTP Dual PVC 500m
Reel
LANconnect/LANmark-5 F¹/UTP LSZH 1000m
Reel
LANconnect/LANmark-5 F¹/UTP LSZH 305m
Box
LANconnect/LANmark-5 F¹/UTP LSZH 500m
Reel
LANconnect/LANmark-5 F¹/UTP PVC 1000m
Reel
LANconnect/LANmark-5 F¹/UTP PVC 305m Box
LANconnect/LANmark-5 F¹/UTP PVC 500m Reel
LANconnect/LANmark-5 U/UTP LSZH 1000m
Reel
LANconnect/LANmark-5 U/UTP LSZH 305m Box
LANconnect/LANmark-5 U/UTP LSZH 500m
Reel
LANconnect/LANmark-5 U/UTP PVC 1000m
Reel
LANconnect/LANmark-5 U/UTP PVC 305m Box
LANconnect/LANmark-5 U/UTP PVC 500m Reel
Type of
cable
F²TP
Shotgun
F²TP
Shotgun
=Make to order,
Category
Outer
sheath
=Make to stock
Flame
retardant
Cat. 5e
LSZH
IEC 60332-1
Cat. 5e
PVC
IEC 60332-1
F²TP
Cat. 5e
LSZH
IEC 60332-1
F²TP
Cat. 5e
LSZH
IEC 60332-1
F²TP
Cat. 5e
PVC
IEC 60332-1
F²TP
F/UTP
Shotgun
F/UTP
Shotgun
Cat. 5e
PVC
IEC 60332-1
Cat. 5e
LSZH
IEC 60332-1
Cat. 5e
PVC
IEC 60332-1
F/UTP
Cat. 5e
LSZH
IEC 60332-1
F/UTP
Cat. 5e
LSZH
IEC 60332-1
F/UTP
Cat. 5e
LSZH
IEC 60332-1
F/UTP
Cat. 5e
PVC
IEC 60332-1
F/UTP
F/UTP
Cat. 5e
Cat. 5e
PVC
PVC
IEC 60332-1
IEC 60332-1
U/UTP
Cat. 5e
LSZH
IEC 60332-1
U/UTP
Cat. 5e
LSZH
IEC 60332-1
U/UTP
Cat. 5e
LSZH
IEC 60332-1
U/UTP
Cat. 5e
PVC
IEC 60332-1
U/UTP
U/UTP
Cat. 5e
Cat. 5e
PVC
PVC
IEC 60332-1
IEC 60332-1
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 24 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Cable
Electrical Performance
all values are specied at 20°C
Frequency
Attenuation
dB/100m
NEXT
dB
ACR
dB/100m
PSNEXT(*)
dB
ELFEXT
dB/100m
PSELFEXT
dB/100m
RL
dB
1
2.1
68.3
66.2
65.3
63.8
61.0
20.0
4
4.0
59.3
55.3
56.3
51.7
49.0
23.0
10
6.3
53.3
47.0
50.3
43.8
41.0
25.0
16
8.0
50.3
42.3
47.3
39.7
36.9
25.0
20
9.0
48.8
39.8
45.8
37.7
35.0
25.0
31.25
11.4
45.9
34.5
42.9
33.9
31.1
23.6
62.5
16.5
41.4
24.9
38.4
27.9
25.1
21.5
100
21.3
38.3
17.0
35.3
23.8
21.0
20.1
155
27.2
35.5
8.3
32.5
19.9
17.2
18.7
(*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the
relevant TIA and IEC cable standards.
Selling delivery information
Installation: Nexans LANconnect/LANmark-5 cables are designed to be installer friendly. The additional performance
headroom provides condence for difcult installations.
03/12/10 - http://www.nexans.co.uk
Page 25 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Snap-In connector
•
•
•
•
•
•
Available in Screened and Unscreened version
Version for stranded wire available, both in Screened and Unscreened
No punchdown tool needed for termination
Reduced risk of installation errors gives consistent performance
Compatible with all Snap-in hardware
Compatible with keystone format using additional clip
Description
Application
The LANmark-5 Snap-in connector range is part of the Nexans modular system
and ts in all structural hardware designed for this range. As such it supports all
data applications dened for Cat 5 and Cat 5e, such as 10baseT, Fast Ethernet,
Gigabit Ethernet, 155 ATM.
Performance
The LANmark-5 Snap-in connector is designed to reach the highest performance
in Cat5e. It has outstanding performance for attenuation (insertion loss), NEXT/
FEXT, Power Sum NEXT/FEXT and Return Loss, exceeding the Cat 5e connector
specs as in ISO/IEC 11801:2002. Used with Nexans LANmark-5 cable and
patchcords, the connector is tested to exceed the link and stringent fourconnector channel requirements as dened in the ISO/IEC 11801:2002 standard.
Guarantees
The LANmark-5 Snap-in connector range is covered by the Nexans guarantee
conform The General Terms and Conditions of Sales. In combination with the
Nexans LANmark-5 product range, the Nexans Certied System Warranty can be
obtained, covering parts, system and labour.
Standards
Installation
International ISO/IEC 11801
The LANmark-5 Snap-in connector range is designed to be terminated by hand,
without punchdown tool. The exclusive construction of the wire organizer makes
termination fast and self-evident. To allow an even quicker and easier installation,
an optional comfort tool can be used (N420.567). This tool includes an extraction
mechanism which makes the connector re-usable. The LANmark-5 snap-in range
is Nexans technology inside and user friendly outside.
National TIA/EIA-568-B.2
•
•
•
•
•
•
Fast and easy termination thanks to wire organiser
No punchdown tool needed
Colour code : T568A and T568B
Re-usable with universal comfort tool (N420.567)
Fits in all Nexans structural hardware for snap-in format
Different versions available: for solid wire and for stranded wire, both in
screened and unscreened version.
03/12/10 - http://www.nexans.co.uk
Page 26 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Snap-In connector
Characteristics
Construction characteristics
Connector type
Dimensional characteristics
Width
Usage characteristics
Range
Product List
Nexans ref.
N420.555
N420.556
N420.550
N420.551
RJ45 and Tool-less IDC
17 mm
LANmark-5
Name
LANmark-5 Screened Snap-In connector
LANmark-5 Screened Snap-In connector for stranded wire
LANmark-5 Unscreened Snap-In connector
LANmark-5 Unscreened Snap-In connector for stranded wire
=Make to order,
=Make to stock
Height (mm)
Screen
23.2
Yes
23.2
Yes
22.9
No
22.9
No
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 27 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Patch Panels
•
•
•
•
•
•
•
Offers headroom to latest Category 5e standard
Sliding mechanism version: easy access from front side and including marking strip
Top connection version supplied with an integrated cabel management plate for tie wrap
LSA+/110 IDC compatible termination
included marking strip
Screened and unscreened version
Suitable for 4 twisted pairs LAN cable and for Voice multipairs cable : access from rear or from side
Description
Application
The LANmark-5 1HU twisted pair patch panel is based on 19" frame dimensions.
In the sliding mechanism version, it is easy to manage thanks to the integrated
Clip-on. In the top connection version, it is easy to manage thanks to the
integrated cable management plate. Both versions provide reliable cable retention
and grounding. The use of patch guides (sold separately) allows an orderly
arrangement of patchcords.
Performance
The LANmark-5 connector has been designed to reach the highest in Cat 5E
performance. It has outstanding performances for attenuation (insertion loss),
NEXT/FEXT per pair, Power Sum NEXT/FEXT and RETURN LOSS. The
LANmark-5 connector module is independently tested and when used with
LANmark-5 cable and patchcords, the 4 connector channel exceeds the Class D
requirements as dened in the ISO/IEC11801 : 2002
Guarantees
The LANmark-5 PCB patch panel is fully compliant with the ISO/IEC11801 :
2002 and exceeds all parameters with large headroom. In combination with the
Nexans LANmark product range, this patch panel offers you a full Class D
warranted solution.
Standards
International ISO/IEC 11801
Installation
The patch panel is equipped with a sliding mechanism or with an integrated cable
management plate for easy front access when mounted into a cabinet. This time
saving mechanism facilitates front side termination.
•
•
•
•
•
•
Easy to install and modify: all operations are performed at the front side.
Supplied with xings.
Available with Nexans LSA+/110 IDC compatible terminations.
Unscreened and screened versions available.
Suitable for multipairs cable
9 pins IDC block for easy termination of drain wire for screened version or 8
pins IDC block for unscreened version
• Colour code T568A and T568B.
• Can be used with all types of cables : F2TP, UTP, S-FTP and STP.
• Accepts 24, 23 and 22 AWG cables.
03/12/10 - http://www.nexans.co.uk
Page 28 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Patch Panels
Characteristics
Dimensional characteristics
Heightunit
Usage characteristics
Category
Range
Number of ports
Product List
Nexans ref.
N500.115
N500.215
N500.205
N500.105
1U
Cat. 5e
LANmark-5
24
Name
LANmark 5 Sliding PCB Patch Panel Screened
LANmark-5 Fixed PCB Patch Panel Screened
LANmark-5 Fixed PCB Patch Panel Unscreened
LANmark-5 Sliding PCB Patch Panel Unscreened
Screen
Yes
Yes
No
No
= Make to order,
03/12/10 - http://www.nexans.co.uk
Depth (mm)
170
137
137
170
= Make to stock
Page 29 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Outlet 45x45
•
•
•
•
•
Offers headroom to latest Category 5e standard.
LSA+ termination
Screened and unscreened version
Single and double connection available
Fits in Nexans structural hardware.
Description
Features
Full Category 5 outlets with better than 40 dB NEXT at 100 MHz between every
pair combination. RJ45 ISO 8877 compliant outlets with T 568B and T 568A pin
conguration.
Fast Foolproof installation:
• IDC contacts at frontside for convenient installation
• IDC colour coding in conformity with cable colour coding
Integrated Outlet Labelling System for easy management and identication
• Labelling window supplied
Versions available: single and double RJ45 connectors, screened and
unscreened.
Country specic covering plates adapt to national requirements and designs.
The connector module is designed to be compatible with any covering plate by
using adaptation rings if required.
These modules t into a complete range of international Covering Plates.
Standards
All plastic material is UL 94V0.
International ISO/IEC 11801
Values
Min. Next Loss (dB)
Min. Return Loss (dB)
40
14
03/12/10 - http://www.nexans.co.uk
Page 30 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 Outlet 45x45
Characteristics
Construction characteristics
Connector type
Dimensional characteristics
External dimensions
Transmission characteristics
Attenuation, max. 100 MHz
Usage characteristics
Range
Product List
Nexans ref.
N462.211
N462.210
N462.201
N462.200
N462.111
N462.110
N462.101
N462.100
RJ45 and LSA+ IDC
45 (H)x 45 (W) x 16(D)mm
0.40 dB/100m
LANmark-5
Name
LANmark-5 Double Outlet 45x45 Screened Ivory with Shutter
LANmark-5 Double Outlet 45x45 Screened White with Shutter
LANmark-5 Double Outlet 45x45 Unscreened Ivory with Shutter
LANmark-5 Double Outlet 45x45 Unscreened White with Shutter
LANmark-5 Single Outlet 45x45 Screened Ivory with Shutter
LANmark-5 Single Outlet 45x45 Screened White with Shutter
LANmark-5 Single Outlet 45x45 Unscreened Ivory with Shutter
LANmark-5 Single Outlet 45x45 Unscreened White with Shutter
=Make to order,
=Make to stock
Colour
Screen
Ivory
No
White RAL 9010
Yes
Ivory
Yes
White RAL 9010
No
Ivory
Yes
White RAL 9010
Yes
Ivory
No
White RAL 9010
No
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 31 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 UniBoot Patch Cords
•
•
•
•
•
Complies fully with Category 5 standards
Uses Nexans cable technology
Fully matched with other components for maximum performance
LSZH Flame retardant jacket or PVC
Retrot Latch Protector available in 8 colours for colour coding
Description
Application
This full Category 5e patch cord maximises the full performance of the channel
and will exceed the requirements of the ISO/IEC 4-connector model, when used
as part of a LANmark-5 cabling Class D solution. This provides improved data
throughput and allows for the inclusion of a Cross-Connect or Consolidation
Points for maximum system exibility.
Screened and unscreened versions available.
LANmark-5 Patch Cords feature a slim over-moulded boot for mechanical
protection, which is kept inside the RJ45 boundaries to enable high density
patching with 48 cords in 1 height unit. A ‘Retrotable’ Latch Protector is available
as accessory, which can be used for colour coding of different services.
Guarantees
• When used with the LANmark-5 system, Cat 5e/Class D channel performance
complies with the channel limits of TIA/EIA-568B and ISO/IEC 11801: 2002 and
a 25 years channel warranty can be obtained.
• Reliable connections.
Standards
International ISO/IEC 11801
National TIA/EIA-568-B.2
Usage
• Small cross section allows neat installation and simplies the creation of
bundles in cabinets.
• Low Smoke Halogen Free - Flame Retardant and PVC jackets are standard.
• 1, 2, 3, 5, 10 and 20m are standard lengths available from stock; other lengths
are available on demand.
• Orange for LSZH and Dark Grey for PVC are standard colours; other colours
(Red, Blue, Yellow and Green) are available on request (in PVC only).
• Rugged construction.
• High connector retention force due to moulded connectors.
• External strain relief.
• Self-latching, high reliability RJ45 (ISO 8877) connectors.
03/12/10 - http://www.nexans.co.uk
Page 32 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 UniBoot Patch Cords
Characteristics
Dimensional characteristics
Nominal outer diameter
Electrical characteristics
Characteristic impedance
Usage characteristics
Range
Mechanical durability/matings
Product List
Nexans ref.
N115.P1B100OU
New
N115.P1B010OU
New
N115.P1B200OU
New
N115.P1B020OU
New
N115.P1B030OU
New
N115.P1B050OU
New
N115.P2B100DU
New
N115.P2B010DU
New
N115.P2B200DU
New
N115.P2B020DU
New
N115.P2B030DU
New
N115.P2B050DU
New
N115.P1A100OU
New
N115.P1A010OU
New
N115.P1A200OU
New
N115.P1A020OU
New
N115.P1A030OU
New
N115.P1A050OU
New
N115.P2A100DU
New
N115.P2A010DU
New
5.5 mm
100 Ohm
LANmark-5
750
=Make to order,
Outer
Length
sheath
(m)
Name
LANmark-5 Patch Cord Cat 5e Screened LSZH 10m
Orange
LANmark-5 Patch Cord Cat 5e Screened LSZH 1m
Orange
LANmark-5 Patch Cord Cat 5e Screened LSZH 20m
Orange
LANmark-5 Patch Cord Cat 5e Screened LSZH 2m
Orange
LANmark-5 Patch Cord Cat 5e Screened LSZH 3m
Orange
LANmark-5 Patch Cord Cat 5e Screened LSZH 5m
Orange
LANmark-5 Patch Cord Cat 5e Screened PVC 10m
Grey
=Make to stock
Colour Screen
LSZH
10
Orange
Yes
LSZH
1
Orange
Yes
LSZH
20
Orange
Yes
LSZH
2
Orange
Yes
LSZH
3
Orange
Yes
LSZH
5
Orange
Yes
PVC
10
Grey
Yes
LANmark-5 Patch Cord Cat 5e Screened PVC 1m Grey
PVC
1
Grey
Yes
LANmark-5 Patch Cord Cat 5e Screened PVC 20m
Grey
PVC
20
Grey
Yes
LANmark-5 Patch Cord Cat 5e Screened PVC 2m Grey
PVC
2
Grey
Yes
LANmark-5 Patch Cord Cat 5e Screened PVC 3m Grey
PVC
3
Grey
Yes
LANmark-5 Patch Cord Cat 5e Screened PVC 5m Grey
PVC
5
Grey
Yes
LSZH
10
Orange
No
LSZH
1
Orange
No
LSZH
20
Orange
No
LSZH
2
Orange
No
LSZH
3
Orange
No
LSZH
5
Orange
No
PVC
10
Grey
No
PVC
1
Grey
No
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 10m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 1m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 20m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 2m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 3m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened LSZH 5m
Orange
LANmark-5 Patch Cord Cat 5e Unscreened PVC 10m
Grey
LANmark-5 Patch Cord Cat 5e Unscreened PVC 1m
Grey
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 33 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-5 UniBoot Patch Cords
Nexans ref.
Name
N115.P2A200DU
New
N115.P2A020DU
New
N115.P2A030DU
New
N115.P2A050DU
New
LANmark-5 Patch Cord Cat 5e Unscreened PVC 20m
Grey
LANmark-5 Patch Cord Cat 5e Unscreened PVC 2m
Grey
LANmark-5 Patch Cord Cat 5e Unscreened PVC 3m
Grey
LANmark-5 Patch Cord Cat 5e Unscreened PVC 5m
Grey
Outer
sheath
Length
(m)
PVC
20
Grey
No
PVC
2
Grey
No
PVC
3
Grey
No
PVC
5
Grey
No
= Make to order,
03/12/10 - http://www.nexans.co.uk
Colour Screen
= Make to stock
Page 34 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Cat 5e Cable
•
•
•
•
•
U/UTP, F/UTP & SF/UTP construction
Complies to latest Cat 5E standards
Supports Gigabit Ethernet
Guaranteed performance to 100MHz
Single foil offers EMC performance
Description
Application
Category 5e cables are the standard 100MHz offering from Nexans.
Manufactured in accordance with TIA 568-B and IEC 61156-5, they are suitable
for basic voice & data installations. Available in Light Grey PVC or Orange LSZH.
Performance
Nexans Category 5e cables are compliant with the requirements of the TIA 568-B
and IEC 61156-5.
Standards
International ISO/IEC 11801
National TIA/EIA-568-B.2
03/12/10 - http://www.nexans.co.uk
Page 35 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Cat 5e Cable
Characteristics
Usage characteristics
Range
Product List
Nexans
ref.
N100.453
N100.463
N100.452
N100.454
N100.451
N100.462
N100.464
N100.461
N100.410
N100.420
N100.407
N100.471
N100.417
N100.476
N100.552
N100.554
N100.551
N100.562
N100.564
N100.561
essential
Name
Type of cable
Essential F/UTP Cat 5e 0,5MM Dual LSZH 500M
REEL
Essential F/UTP Cat 5e 0,5MM Dual PVC 500M
REEL
Essential F/UTP Cat 5e 0,5MM LSZH 1000M
REEL
Essential F/UTP Cat 5e 0,5MM LSZH 500M REEL
Essential F/UTP Cat 5e 0,5MM LSZH BOX 305M
Essential F/UTP Cat 5e 0,5MM PVC 1000M REEL
Essential F/UTP Cat 5e 0,5MM PVC 500M REEL
Essential F/UTP Cat 5e 0,5MM PVC BOX 305M
Essential SF/UTP Cat 5e 0,5MM DUAL LSZH
500M REEL
Essential SF/UTP Cat 5e 0,5MM DUAL PVC 500M
REEL
Essential SF/UTP Cat 5e 0,5MM LSZH 1000M
REEL
Essential SF/UTP Cat 5e 0,5MM LSZH 500M
REEL
Essential SF/UTP Cat 5e 0,5MM PVC 1000M
REEL
Essential SF/UTP Cat 5e 0,5MM PVC 500M REEL
Essential U/UTP Cat 5e 0,5MM LSZH 1000M
REEL
Essential U/UTP Cat 5e 0,5MM LSZH 500M REEL
Essential U/UTP Cat 5e 0,5MM LSZH BOX 305M
Essential U/UTP Cat 5e 0,5MM PVC 1000M REEL
Essential U/UTP Cat 5e 0,5MM PVC 500M REEL
Essential U/UTP Cat 5e 0,5MM PVC Box 305M
F/UTP
Shotgun
F/UTP
Shotgun
=Make to order,
=Make to stock
Length Packaging
Outer
(m)
sheath
500
Reel
LSZH
500
Reel
PVC
F/UTP
1000
Reel
LSZH
F/UTP
F/UTP
F/UTP
F/UTP
F/UTP
SF/UTP
Shotgun
SF/UTP
Shotgun
500
305
1000
500
305
Reel
Box
Reel
Reel
Box
LSZH
LSZH
PVC
PVC
PVC
500
Reel
LSZH
500
Reel
PVC
SF/UTP
1000
Reel
LSZH
SF/UTP
500
Reel
LSZH
SF/UTP
1000
Reel
PVC
SF/UTP
500
Reel
PVC
U/UTP
1000
Reel
LSZH
U/UTP
U/UTP
U/UTP
U/UTP
U/UTP
500
305
1000
500
305
Reel
Box
Reel
Reel
Box
LSZH
LSZH
PVC
PVC
PVC
= Make to order,
= Make to stock
Electrical Performance
all values are specied at 20°C
Frequency
Attenuation
dB/100m
NEXT
dB
ACR
dB/100m
PS NEXT (*)
dB
ELFEXT
dB/100m
PSELFEXT
dB/100m
RL
dB
4
4.1
56.3
52.2
53.3
51.7
49.0
23.0
10
6.5
50.3
43.8
47.3
43.8
41.0
25.0
16
8.3
47.2
38.9
44.3
39.7
36.9
25.0
20
9.3
45.8
36.5
42.8
37.7
35.0
25.0
31.25
11.7
42.9
31.2
39.9
33.9
31.1
23.6
62.5
17.0
38.4
21.4
35.4
27.9
25.1
21.5
100
22.0
35.3
13.3
32.3
23.8
21.0
20.1
03/12/10 - http://www.nexans.co.uk
Page 36 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Cat 5e Cable
(*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the
relevant TIA and IEC cable standards.
03/12/10 - http://www.nexans.co.uk
Page 37 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Snap-In Connector
•
•
•
•
•
•
Complies to the latest Category 5e standard
Fast termination from side or rear
Fits in all Nexans structural hardware
110 and LSA+ termination
An adaptor can be added to t the keystone format
Unscreened or with EMC rear cover
Description
Application
The Nexans Essential Snap-In connector is part of the Nexans modular system
and ts in all structural hardware designed for this range. The Nexans Essential
Range of Cat 5e cabling products are compliant with ISO/IEC 11801 : 2002.
Installation
The Nexans Essential Snap-in connector is a LSA+/110 connector. It is designed
to be terminated by hand, using either 110 or LSA+ termination tool.
•
•
•
•
•
•
•
Advantage: 110 and/or LSA+ termination.
Fast termination of cable from side or rear.
Colour code: T568A and T568B.
A clip can be added to adapt for keystone format.
Fits in all Nexans modular structural hardware of Snap-in.
Modular patch panel also available.
Can be used with all types of cables: U/UTP, F/UTP, F2/UTP ,S/FTP or SF/UTP
(24 AWG, 23 AWG).
• Can be used with or without an EMC rear cover.
• Two positions for the drain wire connection
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 38 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Snap-In Connector
Characteristics
Construction characteristics
Connector type
Usage characteristics
Range
Product List
Nexans ref.
N420.426
N420.416
RJ45 and 110/LSA+ IDC
essential
Name
Essential Screened Snap-In Cat 5e LSA/110 connectivity
Essential Unscreened Snap-In Cat 5e LSA/110 connectivity
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 39 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-5 Keystone Connector
•
•
•
•
•
Complies with the latest Category 5e standards
Unscreened
Fast termination from either side or rear
Fits in all Nexans keystone hardware designed for Essential-5 and -6
110 or LSA+ termination
Description
Application
The Nexans Essential-5 keystone connector is manufactured and tested to the
latest Category 5e specications. It supports Class D applications up to 100 MHz.
When installed in conjunction with Essential-5 cable and patch panels, a 25 year
Class D Link Warranty can be obtained from the Nexans web site.
Design
The Essential-5 keystone connector is designed to match with Essential-5 cable
and patch cords and complements all Essential modular components, such as:
• keystone patch panels (black and white)
• keystone outlet modules (UK, US and European formats)
Please follow the links on this page to view the related datasheets.
Standards
The modular jack is designed for keystone footprints of 14.78 mm width, 20-20.78
mm height and 1.5 mm wall thickness and is compatible with a variety of keystone
formatted structural hardware. (Please check compatibility with Nexans before
using 3rd party hardware)
International ISO/IEC 11801
Performance
The Essential-5 keystone connector is compliant with the specications of ISO/
IEC 11801 and EN 50173.
Installation
•
•
•
•
•
Cable entry from either side or rear.
Wiring according to colour code T568B or T568A.
Termination with 110 or LSA+ punchdown tool.
Accepts 24, 23 and 22 AWG solid core cables.
Fits Nexans hardware designed for keystone format.
03/12/10 - http://www.nexans.co.uk
Page 40 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-5 Keystone Connector
Characteristics
Construction characteristics
Connector type
Usage characteristics
Range
Product List
Nexans ref.
N420.415
New
RJ45 and 110/LSA+ IDC
essential
Name
Essential-5 Keystone Connector Cat 5e Unscreened
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 41 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Patch Panels
• Complies to the latest Category 5e standard
• Punchdown from the top or the rear side
• Unscreened
Description
Application
The Nexans Essential 1HU twisted pair patch panel is based on 19" frame
dimensions. It is easy to manage thanks to the cable guide tie wrap support. The
use of patch guides (sold separately) allows an orderly arrangement of patch
cords.
Performance
The Nexans Essential Range of Cat 5e cabling products are compliant with ISO/
IEC 11801 :2002.
Guarantees
• 20 years link certicate available when installed as part of a Nexans Essential
system.
Installation
•
•
•
•
Supplied with xings.
Unscreened.
Colour code T568A and T568B (Product dependent).
Can be used with all types of cables : U/UTP, F/UTP, F2/UTP, S/FTP, SF/UTP
(23 AWG , 24 AWG).
03/12/10 - http://www.nexans.co.uk
Standards
International ISO/IEC 11801
Page 42 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Patch Panels
Product List
Nexans ref.
N500.202
N424.510
N424.513
N424.511
=Make to order,
=Make to stock
Name
Essential 24 port PCB Patch Panel Rear Connection 1 HU Unscreened
Essential 24 port PCB Patch Panel Rear Connection Black
Essential 24 port PCB Patch Panel Top Connection Black
Essential 48 port PCB Patch Panel Rear Connection Black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 43 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Outlet Modules
•
•
•
•
•
•
Includes 25x50, LJ6C, and triple modules
Complies to the latest Category 5e standards
Unscreened
LSA+ termination
UK white
Fits in all UK Nexans structural hardware
Description
Performance
The Nexans Essential Range of Cat 5e cabling products are compliant with ISO/
IEC 11801 : 2002.
Installation
•
•
•
•
•
•
•
Supplied with tie wraps
Unscreened
Colour code T568B.
Labelling windows supplied
LSA + termination
UK white
Fits in all UK Nexans structural hardware
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 44 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential Outlet Modules
Product List
Nexans ref.
N424.521
N424.520
N424.523
N424.522
To be removed
Name
25x50 Cat 5e Module
25x50 Cat 5e Module - Low Prole
LJ6C Cat 5e Module
Triple Cat 5e Module
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 45 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
essential patchcords
•
•
•
•
Complies to the latest Category 5e standard
Light grey PVC
Screened and unscreened
Moulded strain relief boot
Description
Application
Nexans Essential patch cords are intended to be used to complete the installation
of an "Essential" Category 5e system.
• Flexible grey PVC.
• Moulded strain relief boot.
• 1.5m and 3m standard lengths.
Standards
International ISO/IEC 11801
Flame retardant
IEC 60332-1
03/12/10 - http://www.nexans.co.uk
Page 46 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
essential patchcords
Characteristics
Construction characteristics
Outer sheath
Colour
Electrical characteristics
Characteristic impedance
Usage characteristics
Mechanical durability/matings
Range
Flame retardant
Category
Product List
Nexans ref.
N101.122DGG
N101.122FGG
N101.112DGG
N101.112FGG
PVC
Grey
100 Ohm
100
essential
IEC 60332-1
Cat. 5e
Name
Essential Patch Cord F/UTP Cat 5 1,5m PVC grey
Essential Patch Cord F/UTP Cat 5 3m PVC grey
Essential Patch Cord U/UTP Cat 5 1,5m PVC grey
Essential Patch Cord U/UTP Cat 5 3m PVC grey
Screen
Yes
Yes
No
No
= Make to order,
03/12/10 - http://www.nexans.co.uk
Length (m)
1.5
3
1.5
3
= Make to stock
Page 47 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Category 6 / 6A
LANmark-6 is considered the best horizontal solution for most enterprise
requirements by combining high performance for today, room for growth
tomorrow, and high reliability and efciency. The range of systems include
10Gigabit solutions offering bandwidth up to 500MHz with extensive headroom on
channel performance. Recommended uses:
•
•
•
•
•
Typical 5-10 year building life
Typical enterprise applications - Fast Ethernet & Gigabit Ethernet
10Gigabit varients for high data environments and datacentres
Where reliability is considered vital for business
Typical ofce or indoor light industrial environments
03/12/10 - http://www.nexans.co.uk
Page 48 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 Cable
•
•
•
•
Complies to all Category 6 cable standards
Supports Class E applications
Central cross member maintains geometry and performance
Tested up to 350MHz
Description
Application
LANmark-6 cable is the ultimate solution for a future proof network. It is
specically designed to support the exacting requirements for tomorrow's
protocols, yet is fully backwards compatible with today's needs. It is the
recommended cable for all forthcoming installations.
•
•
•
•
•
•
•
10baseT Ethernet
100baseTX Fast Ethernet
1000baseTX Gigabit Ethernet
155 MBit ATM
622 MBit ATM
1.2 Gbit ATM
Future class E applications
LANmark-6 is independently veried to exceed the requirements of the ISO/IEC
11801:2002 Category 6 requirements.
Performance
Tested to 350 MHz and with guaranteed performance to 250 MHz, Nexans
LANmark-6 cables provide guaranteed headroom and bandwidth over and above
the requirements of all international, european and american cable standards,
including ISO/IEC 11801:2002, IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568B.2-1.
Standards
International EN 50288;
IEC 61156-5; ISO/IEC 11801
National TIA/EIA-568-B.2-1
Installation
LANmark-6 is installed in exactly the same way as Category 5 cables. The C³
central cross member reduces the risk of crushing and kinking.
Guarantees
Nexans LANmark-6 cable is covered by the guarantee that it is Category 6 and by
a parts and labour warranty as described in the Nexans Certied System
Warranty.
03/12/10 - http://www.nexans.co.uk
Page 49 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 Cable
Product List
Nexans
ref.
N100.623
N100.628
N100.622
N100.624
N100.627
N100.629
N100.603
N100.613
N100.601
N100.662
N100.611
N100.661
N100.633
N100.631
N100.632
N100.609
N100.619
N100.606
N100.607
N100.605
N100.616
N100.617
N100.608
Name
Type of cable Category
LANmark-6 F1/UTP Dual LSZH
FTP Shotgun
500m reel
LANmark-6 F1/UTP Dual PVC
FTP Shotgun
500m reel
LANmark-6 F1/UTP LSZH 1000m
F/UTP
reel
LANmark-6 F1/UTP LSZH 500m
F/UTP
reel
LANmark-6 F1/UTP PVC 1000m
F/UTP
reel
LANmark-6 F1/UTP PVC 500m
F/UTP
reel
LANmark-6 F²/UTP Dual LSZH
F²TP Shotgun
500m reel
LANmark-6 F²/UTP Dual PVC
F²TP Shotgun
500m reel
LANmark-6 F²/UTP LSZH 1000m
F²TP
reel
LANmark-6 F²/UTP LSZH 500m
F²TP
reel
LANmark-6 F²/UTP PVC 1000m
F²TP
reel
LANmark-6 F²/UTP PVC 500m
F²TP
reel
LANmark-6 SF/UTP Dual LSZH
SF/UTP
500m reel
Shotgun
LANmark-6 SF/UTP LSZH 1000m
SF/UTP
reel
LANmark-6 SF/UTP LSZH 500m
SF/UTP
reel
LANmark-6 U/UTP Dual LSZH
U/UTP
500m reel
LANmark-6 U/UTP Dual PVC
U/UTP
500m reel
LANmark-6 U/UTP LSZH 1000m
U/UTP
reel
LANmark-6 U/UTP LSZH 305m
U/UTP
Box
LANmark-6 U/UTP LSZH 500m
U/UTP
reel
LANmark-6 U/UTP PVC 1000m
U/UTP
reel
LANmark-6 U/UTP PVC 305m
U/UTP
Box
LANmark-6 U/UTP PVC 500m
U/UTP
reel
=Make to order,
=Make to stock
Outer
Conductor cross-section
sheath
(AWG)
Cat. 6
LSZH
24
Cat. 6
PVC
24
Cat. 6
LSZH
24
Cat. 6
LSZH
24
Cat. 6
PVC
24
Cat. 6
PVC
24
Cat. 6
LSZH
24
Cat. 6
PVC
24
Cat. 6
LSZH
24
Cat. 6
LSZH
24
Cat. 6
PVC
24
Cat. 6
PVC
24
Cat. 6
LSZH
23
Cat. 6
LSZH
23
Cat. 6
LSZH
23
Cat. 6
LSZH
23
Cat. 6
PVC
23
Cat. 6
LSZH
23
Cat. 6
LSZH
23
Cat. 6
LSZH
23
Cat. 6
PVC
23
Cat. 6
PVC
23
Cat. 6
PVC
23
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 50 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 Cable
Electrical Performance
All values are specied at 20°C
Frequency
Attenuation
dB/100m
NEXT
dB
ACR
dB/100m
PSNEXT(*)
dB
ELFEXT
dB/100m
PSELFEXT
dB/100m
RL
dB
1
2.0
74.3
72.3
72.3
70.0
67.0
20.0
4
3.8
65.3
61.5
63.3
58.0
55.0
23.0
10
6.0
59.3
53.3
57.3
50.0
47.0
25.0
16
7.6
56.2
48.6
54.3
45.9
42.9
25.0
20
8.5
54.8
46.3
52.8
44.0
41.0
25.0
31.25
10.7
51.9
41.2
49.9
40.5
37.5
23.6
62.5
15.4
47.4
32.0
45.4
34.1
31.1
21.5
100
19.8
44.3
24.5
42.3
30.0
27.0
20.1
155
25.2
41.4
16.2
39.5
26.2
23.2
18.8
200
29.0
39.8
10.8
37.8
24.0
21.0
18.0
250
32.8
38.3
5.5
36.3
22.0
19.0
17.3
300
36.4
37.1
1.5
35.2
20.5
17.5
16.8
350
39.8
36.1
-
34.2
19.1
16.1
14.1
(*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the
relevant TIA and IEC cable standards.
03/12/10 - http://www.nexans.co.uk
Page 51 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 Snap-In Connector
•
•
•
•
Cat 6 Snap-In available in 3 versions UTP, FTP, EMC.
Fits in all structural hardware designed for this range.
Easy termination, without punch down tool.
An adapter can be added to t the keystone format
Description
Application
The LANmark-6 Toolless Snap-In Connector is part of the Nexans modular
system and ts in all structural hardware designed for this range. As such it
supports all data applications dened for Cat 5, Cat 5e and Cat 6, such as
10baseT, Fast Ethernet, Gigabit Ethernet, 155 ATM, 622 ATM, 1.2 ATM…
Performance
The LANmark-6 Snap-In Connector has been designed to reach the highest
performance in Cat 6 and Class E. It has outstanding performance for attenuation
(insertion loss), NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss,
exceeding the Cat 6 connector specs as in ISO/IEC 11801:2002. The unique
cross-technology in the connector ensures the high performance of the link. Used
with Nexans LANmark-6 cables and patchcords, the connector is independently
tested to exceed the link and stringent four-connector channel requirements as
dened in the ISO/IEC 11801:2002.
Guarantees
The LANmark-6 Snap-In Connector is covered by the guarantee as in 'The
General Terms and Conditions of Sales'. In combination with the Nexans
LANmark-6 product range, the Nexans Certied System Warranty can be
obtained, covering parts, system and labour warranty.
Standards
International ISO/IEC 11801
Installation
The LANmark-6 Snap-In Connector is a toolless connector. It is designed to be
terminated by hand, without punchdown tool. For faster and easier installation of
large volumes, an optional comfort tool can be used.
•
•
•
•
Fast termination of cable
Colour code : TSB568A &TSB568B
Can be used with all types of cables : F²TP, UTP or STP
Accepts 24, 23 and 22 AWG cable
03/12/10 - http://www.nexans.co.uk
Page 52 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 Snap-In Connector
Characteristics
Usage characteristics
Category
Product List
Nexans
ref.
N420.666
New
N420.667
New
N420.660
New
N420.661
New
Cat. 6
=Make to order,
=Make to stock
Height
Width
Range
(mm)
(mm)
Name
LANmark-6 EVO Snap- in connector, Toolless connectivity, screened,
with rear cover (EMC) for solid wire
LANmark-6 EVO Snap-in connector, Toolless connectivity, screened,
with rear cover (EMC) for stranded wire
LANmark-6 EVO Snap-in connector, Toolless connectivity, unscreened
for solid wire
LANmark-6 EVO Snap-in connector, Toolless connectivity, unscreened
for stranded wire
23.2
16.8
LANmark-6
23.2
16.8
LANmark-6
22.9
16.7
LANmark-6
22.9
16.7
LANmark-6
= Make to order,
= Make to stock
Electrical Performance
Frequency
MHz
Attenuation
NEXT pp
PSNEXT
FEXT pp
PSFEXT
RL
1
0.1
94.0
90.0
83.1
80.1
30.0
4
0.1
82.0
78.0
71.1
68.1
30.0
10
0.1
74.0
70.0
63.1
60.1
30.0
16
0.1
69.9
65.9
59.0
56.0
30.0
20
0.1
68.0
64.0
57.1
54.1
30.0
31.25
0.1
64.1
60.1
53.2
50.2
30.0
62.5
0.2
58.1
54.1
47.2
44.2
28.1
100
0.2
54.0
50.0
43.1
40.1
24.0
125
0.2
52.1
48.1
41.2
38.2
22.1
155
0.2
50.2
46.2
39.3
36.3
20.2
175
0.3
49.1
45.1
38.2
35.2
19.1
200
0.3
48.0
44.0
37.1
34.1
18.0
250
0.3
46.0
42.0
35.1
32.1
16.0
All values are in dB
03/12/10 - http://www.nexans.co.uk
Page 53 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 UniBoot Patch Cords
•
•
•
•
•
Complies fully with Category 6 standards
Uses Nexans cable technology
Fully matched with other components for maximum performance
LSZH Flame retardant jacket
Retrot Latch Protector available in 8 colours for colour coding
Description
Application
LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution.
They provide improved data throughput and allow for the inclusion of a crossconnect or Consolidation Points for maximum system exibility. They will also
maximise the lifetime and long term performance of the system by minimising the
risk of wear & tear damage which can be caused by using non-matched cords. .
LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45
boundaries to enable High Density Patching with 48 cords in 1 height unit. They
also come with a Retrot Latch Protector, which can be used for colour coding of
different services.
Guarantees
When installed in combination with other LANmark-6 components, a 25 years
channel warranty can be obtained, covering full Cat 6/Class E compliance.
Installation
• Small cross section allows neat installation and simplies the creation of
bundles in cabinets.
• A Low Smoke Zero Halogen - Flame Retardant jacket is standard.
• 1, 2, 3, 5, 10 and 20m are standard lengths; other lengths are available on
demand.
• Orange and Dark Grey are standard colours available from stock; other colours
are available on demand.
• Default Plug conguration is a black boot with a preinstalled black latch
protector; other combinations available on request.
03/12/10 - http://www.nexans.co.uk
Standards
International EN 50173 Ed.1; ISO/
IEC 11801
National TIA/EIA-568-B.2-1
Page 54 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 UniBoot Patch Cords
Product List
Nexans ref.
N116.P1A100DK
New
N116.P1A100OK
New
N116.P1A010DK
New
N116.P1A010OK
New
N116.P1A200DK
New
N116.P1A200OK
New
N116.P1A020DK
New
N116.P1A020OK
New
N116.P1A030DK
New
N116.P1A030OK
New
N116.P1A050DK
New
N116.P1A050OK
New
Name
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 10m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 10m
Orange
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 1m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 1m
Orange
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m
Orange
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m
Orange
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m
Orange
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m
Grey
LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m
Orange
=Make to order,
=Make to stock
Range
Colour Screen Length (m)
LANmark-6
Grey
No
10
LANmark-6 Orange
No
10
LANmark-6
No
1
LANmark-6 Orange
No
1
LANmark-6
No
20
LANmark-6 Orange
No
20
LANmark-6
No
2
LANmark-6 Orange
No
2
LANmark-6
No
3
LANmark-6 Orange
No
3
LANmark-6
No
5
No
5
Grey
Grey
Grey
Grey
Grey
LANmark-6 Orange
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 55 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 10G UniBoot Patch Cords
• High speed RJ45 patch cord to run 10GBase-T (IEEE 802.3an)
• High Density support : 48 cords on 1 height unit
• Frequency up to 500MHz, fully complies to Cat 6A channel requirements
• Screened Design for Alien Crosstalk immunity
• Externally certied
• Retrot Latch Protector available in 6 colors for color coding
Description
Application
LANmark-6 10G Cords are developed to support 10 Gigabit Ethernet (IEEE
802.3an).
LANmark-6 10G Cords offer superior performance up to 500MHz and are
matched with other LANmark-6 10G components to provide improved data
throughput in complex channel congurations. LANmark-6 10G Cords use
stranded cable and as such provide maximum system exibility for the use at
Cross Connects and Consolidation points.
LANmark-6 10G Cords feature a robust boot which does not extent outside the
RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit
and an Retrot Latch Protector, which can be used for color coding of different
services.
Performance
LANmark-6 10G Cords fully comply and exceed the channel requirements of EIA/
TIA-568-B.2-10 and ISO11801 A2 and enable to achieve high performing 10G
channels.
Standards
Guarantees
When installed in combination with other LANmark-6 10G components, a 25
years channel warranty can be obtained, covering full 10GBase-T support and full
Cat 6A/Class EA compliance.
Usage
International IEEE 802.3an; ISO/
IEC TR24750; ISO11801:2002/
A1:2008
National TIA/EIA TSB-155; TIA/
EIA-568-B.2-10
• The cords are by design fully Alien Crosstalk compliant, so no special
installation rules need to be taken into account for ANEXT and AFEXT
compliance.
• 1, 2, 3, 5, 10, 20m are standard lengths available from stock, other lengths are
available on demand.
• Orange and Dark Grey are standard colours available from stock, other colours
are available on demand.
• Default Plug conguration is a black boot with a preinstalled black latch
protector, other combinations available on request.
03/12/10 - http://www.nexans.co.uk
Page 56 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 10G UniBoot Patch Cords
Product List
Nexans ref.
Name
N11G.P1B100DK
New
N11G.P1B100OK
New
N11G.P1B010DK
New
New
N11G.P1B010OK
New
N11G.P1B200DK
New
N11G.P1B200OK
New
N11G.P1B020DK
New
N11G.P1B020OK
New
N11G.P1B030DK
New
N11G.P1B030OK
New
N11G.P1B050DK
New
N11G.P1B050OK
New
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 10m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 10m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 1m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 1m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 1m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 20m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 20m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 2m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 2m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 3m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 3m Orange
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 5m Grey
LANmark-6 10G Patch Cord Cat 6 500MHz Screened
LSZH 5m Orange
=Make to order,
Range
Length
(m)
LANmark-6
10
10G
LANmark-6
10
10G
LANmark-6
1
10G
LANmark-6
1
10G
LANmark-6
1
10G
LANmark-6
20
10G
LANmark-6
20
10G
LANmark-6
2
10G
LANmark-6
2
10G
LANmark-6
3
10G
LANmark-6
3
10G
LANmark-6
5
10G
LANmark-6
5
10G
= Make to order,
=Make to stock
Colour Screen
Grey
Yes
Orange
Yes
Grey
Yes
Orange
Yes
Orange
Yes
Grey
Yes
Orange
Yes
Grey
Yes
Orange
Yes
Grey
Yes
Orange
Yes
Grey
Yes
Orange
Yes
= Make to stock
Electrical Performance LANmark-6 10G 100m 4 connector channel
all values are specied at 20°C
Attn
dB
Freq
Std
NEXT
dB
Guar
Std
PSNEXT
dB
ELFEXT
dB
Guar
Std
Guar
Std
PS ELFEXT
dB
PS ANEXT
dB
PS AELFEXT
dB
RL
dB
Guar
Std
Guar
Std
Guar
Std
Guar
Std
Guar
1
<4
<4
72.7
>75
70.3
74.3
63.3
>60
60.3
>60
82.0
>90
77.9
87.9
19.0
21.0
4
4.2
4.1
63.0
66.0
60.5
64.5
51.2
57.2
48.2
57.2
76.0
>90
65.9
75.9
19.0
21.0
10
6.6
6.5
56.6
59.6
54.0
58.0
43.3
49.3
40.3
49.3
72.0
87.0
57.9
67.9
19.0
21.0
16
8.3
8.2
53.2
56.2
50.6
54.6
39.2
45.2
36.2
45.2
70.0
85.0
53.8
63.8
18.0
20.0
20
9.3
9.2
51.6
54.6
49.0
53.0
37.2
43.2
34.2
43.2
69.0
84.0
51.9
61.9
17.5
19.5
31.25 11.7
11.6
48.4
51.4
45.7
49.7
33.4
39.4
30.4
39.4
67.1
82.1
48.0
58.0
16.5
18.5
62.5
16.9
16.6
43.4
46.4
40.6
44.6
27.3
33.3
24.3
33.3
64.0
79.0
42.0
52.0
14.0
16.0
100
21.7
21.4
39.9
42.9
37.1
41.1
23.3
29.3
20.3
29.3
62.0
77.0
37.9
47.9
12.0
14.0
155
27.6
27.1
36.7
39.7
33.8
37.8
19.5
25.5
16.5
25.5
59.1
74.1
34.1
44.1
10.1
12.1
200
31.7
31.2
34.8
37.8
31.9
35.9
17.2
23.2
14.2
23.2
57.5
72.5
31.9
41.9
9.0
11.0
250
35.9
35.4
33.1
36.1
30.2
34.2
15.3
21.3
12.3
21.3
56.0
71.0
29.9
39.9
8.0
10.0
300
39.8
39.2
31.7
34.7
28.8
32.8
13.7
19.7
10.7
19.7
54.8
69.8
28.4
38.4
7.2
9.2
500
53.4
52.6
22.0
25.0
20.4
24.4
9.3
15.3
6.3
15.3
51.5
66.5
23.9
33.9
6.0
8.0
Guaranteed channel values apply under the condition that General Installation Guidelines from NCS and the Design and
Installation Guidelines for LANmark-6 10G are respected and implemented.
03/12/10 - http://www.nexans.co.uk
Page 57 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 10G Snap-In Connector
•
•
•
•
•
•
Complies to 10GBase-T application standards
Complies with Category 6A and Class EA channel requirements
Fully screened for alien crosstalk immunity
Reduces risk of installation errors for consistent performance
Compatible with all snap-in hardware
An adapter can be added to t the keystone format
Description
Application
LANmark-6 10G consists of screened components specied to frequencies up to
500MHz. They have been designed specically to support the higher frequencies
required for 10 Gigabit Ethernet, yet is fully backwards compatible with today's
needs. The LANmark-6 10G EVO connector ts in all structural hardware
designed for the EVO snap-in range. In addition to the requirements of the EIA/
TIA 568-B.2-1 and ISO/IEC 11801:2002 Category 6, the LANmark-6 10G
products are additionally specied to 500MHz and are screened to ensure
immunity from Alien Crosstalk and other external interference.
•
•
•
•
•
•
•
10Base-T Ethernet
100Base-TX Fast Ethernet
1000Base-TX Gigabit Ethernet
10GBase-T 10 Gigabit Ethernet IEEE 802.3
155 Mbit ATM
1.2 Gbit ATM
future class E 10G applications
Performance
The LANmark-6 10G EVO Snap-in connector has been designed to reach the
highest performance in Cat 6 and Class E up to 500 MHz. It has outstanding
performance for attenuation (insertion loss), NEXT/FEXT, Power Sum NEXT/
FEXT and Return Loss, exceeding the Cat 6 connector specs as in IEC
60603-7-5.
Standards
International IEEE 802.3an; ISO/
IEC TR24750; ISO11801:2002/
A1:2008
National TIA/EIA TSB-155; TIA/
EIA-568-B.2-10
When used in combination with Nexans LANmark-6 10G cables and LANmark-6
10G Ultim patch cords, and installed according to the guidelines, the system
supports the 10GBase-T applications as dened in IEEE 802.3an, ISO/IEC TR
24750 and TIA/EIA TSB-155. Respecting the Nexans LANmark-6 10G design
guidelines, the full 100m four-connector channel moreover meets Category 6A
and Class EA requirements as dened in TIA/EIA568B.2 Addendum 10 draft 6.0
and ISO/IEC draft amendment 1.1 (as in draft 25N1324) respectively.
Installation
The LANmark-6 10G EVO Snap-in connector makes termination easier and
quicker thanks to exclusive design of the wire organizer and of the sliding metal
EMC rear cover. The LANmark-6 10G EVO snap-in is designed to be
terminated with the universal comfort tool. This tool includes also the exclusive
extraction mechanism which makes the EVO series snap-in re-usable. A stranded
version is available for reliable termination in consolidation point of 3 or 4
connectors channel models. The LANmark-6 10G EVO snap-in range is Nexans
technology inside and user friendly outside
03/12/10 - http://www.nexans.co.uk
Page 58 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 10G Snap-In Connector
•
•
•
•
•
•
•
•
Fast termination with exclusive wire organizer and sliding metal EMC rear cover
Colour code : T568A &T568B
Full EMC protection with metal rear cover
Re-usable with universal comfort tool
Accepts solid wire from 22 to 24 AWG
Stranded version available for consolidation point
Snap-in format ts in all Nexans structural hardware
2 possibilities to terminate the drain wire : on the housing or on the rear cover
Guarantees
The LANmark-6 10G EVO Snap-in connector is covered by the guarantee as in
The General Terms and Conditions of Sales. When installed in combination with
other LANmark-6 10G components, a 25 years channel warranty can be
obtained, covering 10GBase-T support in accordance with IEEE 802.3an. Also if
following the design guidelines for LANmark-6 10G systems and tested
accordingly, a 25 year warranty can be obtained to Category 6A or Class EA
requirements.
03/12/10 - http://www.nexans.co.uk
Page 59 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6 10G Snap-In Connector
Characteristics
Usage characteristics
Range
LANmark-6 10G
Product List
Nexans ref.
N420.666G
New
N420.667G
New
Name
LANmark-6 10G EVO Snap-in connector, screened, for solid wire
LANmark-6 10G EVO Snap-in connector, screened, for stranded wire
= Make to order,
= Make to stock
Electrical Performance LANmark-6 10G 100m 4 connector channel
all values are specied at 20°C
Attn
dB
Freq
Std
NEXT
dB
Guar
Std
PSNEXT
dB
ELFEXT
dB
Guar
Std
Guar
Std
PS ELFEXT
dB
PS ANEXT
dB
PS AELFEXT
dB
RL
dB
Guar
Std
Guar
Std
Guar
Std
Guar
Std
Guar
1
<4
<4
72.7
>75
70.3
74.3
63.3
>60
60.3
>60
82.0
>90
77.9
87.9
19.0
21.0
4
4.2
4.1
63.0
66.0
60.5
64.5
51.2
57.2
48.2
57.2
76.0
>90
65.9
75.9
19.0
21.0
10
6.6
6.5
56.6
59.6
54.0
58.0
43.3
49.3
40.3
49.3
72.0
87.0
57.9
67.9
19.0
21.0
16
8.3
8.2
53.2
56.2
50.6
54.6
39.2
45.2
36.2
45.2
70.0
85.0
53.8
63.8
18.0
20.0
20
9.3
9.2
51.6
54.6
49.0
53.0
37.2
43.2
34.2
43.2
69.0
84.0
51.9
61.9
17.5
19.5
31.25 11.7
11.6
48.4
51.4
45.7
49.7
33.4
39.4
30.4
39.4
67.1
82.1
48.0
58.0
16.5
18.5
62.5
16.9
16.6
43.4
46.4
40.6
44.6
27.3
33.3
24.3
33.3
64.0
79.0
42.0
52.0
14.0
16.0
100
21.7
21.4
39.9
42.9
37.1
41.1
23.3
29.3
20.3
29.3
62.0
77.0
37.9
47.9
12.0
14.0
155
27.6
27.1
36.7
39.7
33.8
37.8
19.5
25.5
16.5
25.5
59.1
74.1
34.1
44.1
10.1
12.1
200
31.7
31.2
34.8
37.8
31.9
35.9
17.2
23.2
14.2
23.2
57.5
72.5
31.9
41.9
9.0
11.0
250
35.9
35.4
33.1
36.1
30.2
34.2
15.3
21.3
12.3
21.3
56.0
71.0
29.9
39.9
8.0
10.0
300
39.8
39.2
31.7
34.7
28.8
32.8
13.7
19.7
10.7
19.7
54.8
69.8
28.4
38.4
7.2
9.2
500
53.4
52.6
22.0
25.0
20.4
24.4
9.3
15.3
6.3
15.3
51.5
66.5
23.9
33.9
6.0
8.0
Guaranteed channel values apply under the condition that General Installation Guidelines from NCS and the Design and
Installation Guidelines for LANmark-6 10G are respected and implemented.
03/12/10 - http://www.nexans.co.uk
Page 60 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Cable
•
•
•
•
•
Ideal Cable for 10GBase-T application
Complies fully with new standards for Category 6A and Class EA
Small diameter
Guaranteed performance up to 500MHz
Fully screened for alien crosstalk immunity
Description
Application
LANmark-6A cable is the ideal solution for a 10 Gigabit Ethernet network. The
range consists of cables which have been designed specically to support the
higher frequencies required for 10 Gigabit Ethernet, while maintain to be fully
backwards compatible with today's needs. All LANmark-6A products are screened
cables to ensure immunity from Alien Crosstalk and other external interference
and are specied up to frequencies of 500MHz.
•
•
•
•
•
•
•
10Base-T Ethernet
100Base-TX Fast Ethernet
1000Base-TX Gigabit Ethernet
10GBase-T 10 Gigabit Ethernet IEEE 802.3
155 Mbit ATM
1.2 Gbit ATM
future Cat 6A and Class EA applications
Performance
With guaranteed performance to 500MHz, Nexans LANmark-6A cables provide
guaranteed headroom and bandwidth over and above the Category 6A
requirements of international, european and american cable standards, including
of IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568-B.2-1 Ad.10. When used in
combination with Nexans LANmark-6A Evo connectors and LANmark-6A Ultim
patch cords, the system supports the 10GBase-T applications as dened in IEEE
802.3an, and the full 100m four-connector links and channels meet Category 6A
and Class EA requirements as dened in TIA/EIA568B.2 Addendum 10 and ISO/
IEC11801 2002/A1:2008.
International EN 50288-4-1;
IEC 61156-5; IEEE 802.3an; ISO/
IEC 11801:2002/A2:2008; ISO/
IEC 24764; ISO/IEC TR24750;
ISO11801:2002/A1:2008
Installation
National ANSI/TIA-568-C.2; TIA/
EIA TSB-155
Standards
The LANmark-6A cables have the advantage of offering equal dimensions and
exibility as the equivalent LANmark-6 screened cables with the same ease of
installation and termination.
Guarantees
Nexans LANmark-6A 10G cable is covered by a parts and labour warranty as
described in the Nexans Certied System Warranty. When installed in
combination with other LANmark-6A 10G components, a 25 year channel
warranty can be obtained.
03/12/10 - http://www.nexans.co.uk
Page 61 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Cable
=Make to order,
Product List
Nexans ref.
N100.693G
N100.698G
N100.692G
N100.694G
N100.697G
N100.699G
N100.623G
N100.622G
N100.624G
Name
LANmark-6A F/FTP Cat 6A 500MHz Dual LSZH 500m reel
LANmark-6A F/FTP Cat 6A 500MHz Dual PVC 500m reel
LANmark-6A F/FTP Cat 6A 500MHz LSZH 1000m reel
LANmark-6A F/FTP Cat 6A 500MHz LSZH 500m reel
LANmark-6A F/FTP Cat 6A 500MHz PVC 1000m reel
LANmark-6A F/FTP Cat 6A 500MHz PVC 500m reel
LANmark-6A F1/UTP Cat 6A 500MHz Dual LSZH 500m reel
LANmark-6A F1/UTP Cat 6A 500MHz LSZH 1000m reel
LANmark-6A F1/UTP Cat 6A 500MHz LSZH 500m reel
=Make to stock
Outer sheath
LSZH
PVC
LSZH
LSZH
PVC
PVC
LSZH
LSZH
LSZH
= Make to order,
= Make to stock
Electrical Performance LANmark-6A 10G F1UTP cable
Attn
Freq
in dB
NEXT
in dB
PSNEXT
in dB
ACR-F
in dB
PS ACR-F
in dB
in MHz
Max.
Typ.
Min.
Typ.
Min.
Typ.
Min.
Typ.
Min.
1
2.1
2.1
74.3
79.3
72.3
77.3
67.8
92.8
4
3.8
3.8
65.3
70.3
63.3
68.3
55.8
80.8
10
5.9
5.9
59.3
64.3
57.3
62.3
47.8
16
7.5
7.5
56.2
61.2
54.2
59.2
43.7
PS ANEXT
in dB
PS AACR-F
in dB
RL
in dB
Typ.
Min.
Typ.
Min.
Typ.
Min.
Typ.
64.8
>60
67.0
90.0
67.0
87.9
20.0
26.0
52.8
57.2
67.0
90.0
66.2
75.9
23.0
29.0
72.8
44.8
49.3
67.0
87.0
58.2
67.9
25.0
31.0
68.7
40.7
45.2
67.0
85.0
54.1
63.8
25.0
31.0
20
8.4
8.4
54.8
59.8
52.8
57.8
41.8
66.8
38.8
43.2
67.0
84.0
52.2
61.9
25.0
31.0
31.25
10.5
10.5
51.9
56.9
49.9
54.9
37.9
62.9
34.9
39.4
67.0
82.1
48.3
58.0
23.6
29.6
62.5
15.0
15.0
47.4
52.4
45.4
50.4
31.9
56.9
28.9
33.3
65.6
79.0
42.3
52.0
21.5
27.5
100
19.1
19.1
44.3
49.3
42.3
47.3
27.8
52.8
24.8
29.3
62.5
77.0
38.2
47.9
20.1
26.1
155
24.1
24.1
41.4
46.4
39.4
44.4
24.0
49.0
21.0
25.5
59.6
74.1
34.4
44.1
18.8
24.8
200
27.6
27.6
39.8
44.8
37.8
42.8
21.8
46.8
18.8
23.2
58.0
72.5
32.2
41.9
18.0
24.0
250
31.1
31.1
38.3
43.3
36.3
41.3
19.8
44.8
16.8
21.3
56.5
71.0
30.2
39.9
17.3
23.3
300
34.3
34.3
37.1
42.1
35.1
40.1
18.3
43.3
15.3
19.7
55.3
69.8
28.7
38.4
16.8
22.8
500
45.3
45.3
33.8
38.8
31.8
36.8
13.8
38.8
10.8
15.3
52.0
66.5
24.2
33.9
15.2
21.2
all values are specied at 20°C
03/12/10 - http://www.nexans.co.uk
Page 62 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Connector
•
•
•
•
•
High bandwidth RJ45 connector to support 10Gigabit Ethernet
Fully complies to TIA and ISO Cat 6A cabling standards
Supports extremely short Cat 6A channel congurations needed for datacenters
Fully screened for alien crosstalk immunity
Compatible with all Snap-In panels and outlets
Description
Application
LANmark-6A EVO Snap-In Connector is a screened RJ45 cable jack specied up
to 500MHz. It is designed specically to support the high frequencies required for
10 Gigabit Ethernet, but is also fully backwards-compatible with lower frequency
applications using the RJ45 interface. LANmark-6A EVO uses a fully closed rear
cover, which provides 360° screening and excellent coupling attenuation to
ensure immunity from alien crosstalk and other external interference. Cabling
channels with LANmark-6A cable jack have not to be veried on site for Alien
Crosstalk, as this new 10G parameter is met by design. This reduces signicantly
the cost for 10G networking.
•
•
•
•
•
•
•
10Base-T Ethernet
100Base-TX Fast Ethernet
1000Base-TX Gigabit Ethernet
10GBase-T 10 Gigabit Ethernet IEEE 802.3
155 Mbit ATM
1.2 Gbit ATM
all future Cat 6A and Class EA applications
Performance
The LANmark-6A EVO has outstanding electrical performance up to 500MHz
especially for NEXT/FEXT, Power Sum NEXT/FEXT, Return Loss and all
screening parameters. This enables to achieve high performing Cat 6A channels
as well as very short link and channel congurations needed in data centres with
up to 3 connection points within 12 meters.
Standards
International EN 50173-1;
EN 50173-3; IEC 60603-7-5;
IEC 60603-7-51; ISO/
IEC 11801:2002/A2:2008; ISO/
IEC 24764; ISO11801:2002/A1:2008
National ANSI/TIA-568-C.2
Installation
LANmark-6A EVO makes use of Nexans wire organiser and is therefore very
easy and fast to terminate. Using the Nexans comfort tool installation tool EVO
Snap-In series is re-usable. A stranded version is available to allow the use of
exible stranded cable in cross connects or consolidation point.
The LANmark-6A EVO ts in all structural hardware designed for the EVO SnapIn range and can used in all positions of a 4 connector twisted pair cabling
channel (PP, CC, CP, TO).
• Fast termination with exclusive wire organizer and hinging metal EMC rear
cover
• Colour code : T568A &T568B
• 360° EMC protection
• Re-usable with universal comfort tool
• Accepts solid wire from 22 to 24 AWG
• Stranded version available for consolidation point
• Snap-in format ts in all Nexans structural hardware
• 2 possibilities to terminate the drain wire : on the housing or on the rear cover
• Can be turned into keystone format using an additional adapter
Guarantees
When installed in combination with other LANmark-6A components, a 25 years
channel warranty can be obtained, covering full 10GBase-T support and full Cat
6A/Class EA compliance
03/12/10 - http://www.nexans.co.uk
Page 63 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Connector
Product List
Nexans ref.
N420.66A
New
N420.67A
New
Name
LANmark-6A Snap-In Connector Cat 6A 500MHz Screened
LANmark-6A Snap-In Connector Cat 6A 500MHz Screened for stranded wire
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 64 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Connector
Electrical Performance LANmark-6A 4 Connector Channel Part 1
"All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance"
Attn
Freq
in MHz
NEXT
in dB
PSNEXT
in dB
ACR-F
in dB
in dB
Max
Typ
Std
Min
Typ
Std
Min
Typ
Std
Typ
1
<4
4.0
65.0
67.0
85.0
62.0
64.0
74.8
63.3
69.9
4
4.1
4.1
63.0
65.0
72.9
60.5
62.5
65.0
51.2
57.9
10
6.4
6.3
56.6
58.6
65.0
54.0
56.0
58.5
43.3
49.9
16
8.1
8.0
53.2
55.2
60.9
50.6
52.6
55.1
39.2
45.9
20
9.1
9.0
51.6
53.6
59.0
49.0
51.0
53.5
37.2
43.9
31.25
11.4
11.2
48.4
50.4
55.1
45.7
47.7
50.2
33.4
40.0
62.5
16.3
15.9
43.4
45.4
49.1
40.6
42.6
45.1
27.3
34.0
100
20.8
20.2
39.9
41.9
45.0
37.1
39.1
41.6
23.3
29.9
155
26.2
25.4
36.7
38.7
41.2
33.8
35.8
38.3
19.5
26.1
200
30.0
28.9
34.8
36.8
39.0
31.9
33.9
36.4
17.2
23.9
250
33.8
32.5
33.1
35.1
37.0
30.2
32.2
34.7
15.3
22.0
300
37.3
35.7
31.7
33.7
35.4
28.8
30.8
33.3
13.7
20.4
500
49.3
46.7
27.9
29.9
31.0
24.8
26.8
24.9
9.3
16.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
Electrical Performance LANmark-6A 4 Connector Channel Part 2
All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance
PS ACR-F
Freq
PS ANEXT
in dB
PS AACR-F
in dB
RL
in dB
in dB
in MHz
Std
Typ
Std
Min
Typ
Std
Min
Typ
Std
Min
Typ
1
60.3
66.9
80.0
90.0
92.0
77.0
92.0
94.0
19.0
21.0
21.0
4
48.2
54.9
74.0
89.0
91.0
65.0
80.0
82.0
19.0
21.0
32.0
10
40.3
46.9
70.0
85.0
87.0
57.0
72.0
74.0
19.0
21.0
28.0
16
36.2
42.9
68.0
83.0
85.0
52.9
67.9
69.9
18.0
20.0
26.0
20
34.2
40.9
67.0
82.0
84.0
51.0
66.0
68.0
17.5
19.5
25.0
31.25
30.4
37.0
65.1
80.1
82.1
47.1
62.1
64.1
16.5
18.5
23.1
62.5
24.3
31.0
62.0
77.0
79.0
41.1
56.1
58.1
14.0
16.0
20.0
100
20.3
26.9
60.0
75.0
77.0
37.0
52.0
54.0
12.0
14.0
18.0
155
16.5
23.1
57.1
72.1
74.1
33.2
48.2
50.2
10.1
12.1
16.1
200
14.2
20.9
55.5
70.5
72.5
31.0
46.0
48.0
9.0
11.0
15.0
250
12.3
19.0
54.0
69.0
71.0
29.0
44.0
46.0
8.0
10.0
14.0
300
10.7
17.4
52.8
67.8
69.8
27.5
42.5
44.5
8.0
10.0
13.2
500
6.3
13.0
49.5
64.5
66.5
23.0
38.0
40.0
8.0
10.0
11.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
03/12/10 - http://www.nexans.co.uk
Page 65 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Ultim UniBoot Patch Cords
•
•
•
•
•
•
High speed RJ45 patch cord to run 10GBase-T and future Cat6A applications
High Density support : 48 cords on 1 height unit
Frequency range up to 500MHz, fully complies to Cat 6A TIA568B.2-10 and ISO11801(2010) A2
Individually screened pairs for reduced Internal Crosstalk and Alien Crosstalk immunity
Externally certied
Retrot Latch Protector available in 8 colours for colour coding
Description
Application
LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE
802.3an) and any other future Cat.6A application.
LANmark-6A Ultim Cords offer superior performance up to 500MHz and are
matched with other LANmark-6A components to provide improved data
throughput in complex channel congurations. Ultim cords use stranded cable
and as such provide maximum system exibility for the use at Cross Connects
and Consolidation points.
They will also maximise the lifetime and longevity of the system by minimising the
risk of wear & tear damage. Due to their good electrical performance and
mechanical stability, LANmark-6A Ultim cords can be used for accurate eld
testing of Cat 6A cabling channels. .
Ultim Cords feature a slim boot for mechanical protection, which is kept inside the
RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit.
They also come with a ‘Replaceable’ Latch Protector, which can be used for
colour coding of different services.
Performance
Standards
The LANmark-6A Ultim cords fully comply and exceed the requirements of EIA/
TIA-568-B.2-10 and ISO11801 A2 and enable to achieve high performing Cat 6A
channels. Used with other LANmark-6A components, very short Cat 6A link and
channel congurations with up to 3 connection points within 10 meters can be
supported.
International EN 50173-1;
IEEE 802.3an; ISO/IEC 11801:2002/
A2:2008; ISO/IEC TR24750;
ISO11801:2002/A1:2008
National TIA/EIA TSB-155; TIA/
EIA-568-B.3
Guarantees
When installed in combination with other LANmark-6A components, a 25 years
channel warranty can be obtained, covering full 10GBase-T support and full Cat
6A/Class EA compliance.
Usage
• The cords are by design fully Alien Crosstalk compliant, so no special
installation rules need to be taken into account for ANEXT and AFEXT
compliance.
• 1, 2, 3, 5, 10, 20m are standard lengths available from stock, other lengths are
available on demand.
• Orange and Dark Grey are standard colours available from stock; other colours
are available on demand.
• Default Plug Conguration is a black boot with a preinstalled black latch
protector.
Characteristics
Usage characteristics
Range
LANmark-6A
03/12/10 - http://www.nexans.co.uk
Page 66 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Ultim UniBoot Patch Cords
Product List
Nexans ref.
N11A.U1F100DK
New
N11A.U1F100OK
New
N11A.U1F010DK
New
N11A.U1F010OK
New
N11A.U1F200DK
New
N11A.U1F200OK
New
N11A.U1F020DK
New
N11A.U1F020OK
New
N11A.U1F030DK
New
N11A.U1F030OK
New
N11A.U1F050DK
New
N11A.U1F050OK
New
=Make to order,
=Make to stock
Length (m) Colour Screen
Name
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 10m Grey
10
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 10m Orange
10
Orange
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 1m Grey
1
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 1m Orange
1
Orange
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 20m Grey
20
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 20m Orange
20
Orange
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 2m Grey
2
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 2m Orange
2
Orange
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 3m Grey
3
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 3m Orange
3
Orange
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 5m Grey
5
Grey
Yes
LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 5m Orange
5
Orange
Yes
= Make to order,
= Make to stock
Electrical Performance LANmark-6A 4 Connector Channel Part 1
"All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance"
Attn
Freq
in MHz
NEXT
in dB
PSNEXT
in dB
ACR-F
in dB
in dB
Max
Typ
Std
Min
Typ
Std
Min
Typ
Std
Typ
1
<4
4.0
65.0
67.0
85.0
62.0
64.0
74.8
63.3
69.9
4
4.1
4.1
63.0
65.0
72.9
60.5
62.5
65.0
51.2
57.9
10
6.4
6.3
56.6
58.6
65.0
54.0
56.0
58.5
43.3
49.9
16
8.1
8.0
53.2
55.2
60.9
50.6
52.6
55.1
39.2
45.9
20
9.1
9.0
51.6
53.6
59.0
49.0
51.0
53.5
37.2
43.9
31.25
11.4
11.2
48.4
50.4
55.1
45.7
47.7
50.2
33.4
40.0
62.5
16.3
15.9
43.4
45.4
49.1
40.6
42.6
45.1
27.3
34.0
100
20.8
20.2
39.9
41.9
45.0
37.1
39.1
41.6
23.3
29.9
155
26.2
25.4
36.7
38.7
41.2
33.8
35.8
38.3
19.5
26.1
200
30.0
28.9
34.8
36.8
39.0
31.9
33.9
36.4
17.2
23.9
250
33.8
32.5
33.1
35.1
37.0
30.2
32.2
34.7
15.3
22.0
300
37.3
35.7
31.7
33.7
35.4
28.8
30.8
33.3
13.7
20.4
500
49.3
46.7
27.9
29.9
31.0
24.8
26.8
24.9
9.3
16.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
03/12/10 - http://www.nexans.co.uk
Page 67 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Ultim UniBoot Patch Cords
Electrical Performance LANmark-6A 4 Connector Channel Part 2
All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance
PS ACR-F
Freq
PS ANEXT
in dB
PS AACR-F
in dB
RL
in dB
in dB
in MHz
Std
Typ
Std
Min
Typ
Std
Min
Typ
Std
Min
Typ
1
60.3
66.9
80.0
90.0
92.0
77.0
92.0
94.0
19.0
21.0
21.0
4
48.2
54.9
74.0
89.0
91.0
65.0
80.0
82.0
19.0
21.0
32.0
10
40.3
46.9
70.0
85.0
87.0
57.0
72.0
74.0
19.0
21.0
28.0
16
36.2
42.9
68.0
83.0
85.0
52.9
67.9
69.9
18.0
20.0
26.0
20
34.2
40.9
67.0
82.0
84.0
51.0
66.0
68.0
17.5
19.5
25.0
31.25
30.4
37.0
65.1
80.1
82.1
47.1
62.1
64.1
16.5
18.5
23.1
62.5
24.3
31.0
62.0
77.0
79.0
41.1
56.1
58.1
14.0
16.0
20.0
100
20.3
26.9
60.0
75.0
77.0
37.0
52.0
54.0
12.0
14.0
18.0
155
16.5
23.1
57.1
72.1
74.1
33.2
48.2
50.2
10.1
12.1
16.1
200
14.2
20.9
55.5
70.5
72.5
31.0
46.0
48.0
9.0
11.0
15.0
250
12.3
19.0
54.0
69.0
71.0
29.0
44.0
46.0
8.0
10.0
14.0
300
10.7
17.4
52.8
67.8
69.8
27.5
42.5
44.5
8.0
10.0
13.2
500
6.3
13.0
49.5
64.5
66.5
23.0
38.0
40.0
8.0
10.0
11.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
03/12/10 - http://www.nexans.co.uk
Page 68 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Cable
•
•
•
•
Unshielded construction
Complies to the latest Category 6 standards
Central cross maintains geometry and performance
Supports Class E applications up to 250 MHz.
Description
Application
The Nexans Essential-6 cables are manufactured and tested to the latest
Category 6 specications. They are compatible with the complete Essential-6
modular and PCB connectivity range. When the cable is installed in conjunction
with Essential-6 outlets and patch panels, a 25 year Class E Link Certicate can
be obtained from the Nexans website.
Design
The conductors are 24 AWG solid copper wires complying with IEC 60228. The
PE central cross ller keeps the pairs in place and reduces the risks of losing
performance when bending the cable. The cable is available with a Light Grey
PVC or an Orange LSZH outer jacket.
Performance
Nexans Essential-6 cables are compliant with the requirements of the TIA 568B.2-1 and ISO/IEC 11801:2002.
Installation
Thanks to their small nominal outer diameter, the Essential-6 cables are as easy
to install as their Cat 5e equivalent.
Standards
International ISO/IEC 11801
National TIA/EIA-568-B.2
03/12/10 - http://www.nexans.co.uk
Page 69 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Cable
Characteristics
Usage characteristics
Range
Product List
Nexans ref.
N100.161
New
N100.164
New
N100.166
New
N100.169
New
essential-6
Name
Type of cable
Outer sheath
Essential-6 U/UTP Cat 6 LSZH 305m box
U/UTP
LSZH
Essential-6 U/UTP Cat 6 LSZH 500m reel
U/UTP
LSZH
Essential-6 U/UTP Cat 6 PVC 305m box
U/UTP
PVC
Essential-6 U/UTP Cat 6 PVC 500m reel
U/UTP
PVC
= Make to order,
= Make to stock
Channel Performance
Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel.
Frequency MHz
Insertion Loss NEXT PP PS NEXT
ACR
PS ACR ELFEXT PSELFEXT Return Loss
dB/100m
dB
dB
dB/100m dB/100m dB/100m dB/100m
dB
1
4.0
65.0
62.0
65.0
62.0
63.3
60.3
19.0
4
4.2
63.0
60.5
58.9
56.4
51.2
48.2
19.0
10
6.6
56.6
54.0
50.0
47.4
43.3
40.3
19.0
16
8.3
53.2
50.6
44.9
42.3
39.2
36.2
18.0
20
9.3
51.6
49.0
42.3
39.7
37.2
34.2
17.5
31.25
11.7
48.4
45.7
36.7
34.0
33.4
30.4
16.5
62.5
16.9
43.4
40.6
26.5
23.7
27.3
24.3
14.0
100
21.7
39.9
37.1
18.2
15.4
23.3
20.3
12.0
155
27.6
36.7
33.8
9.1
6.2
19.5
16.5
10.1
200
31.7
34.8
31.9
3.1
0.1
17.2
14.2
9.0
250
35.9
33.1
30.2
-2.8
-5.8
15.3
12.3
8.0
All values are specied at 20°C.
03/12/10 - http://www.nexans.co.uk
Page 70 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Keystone Connector
•
•
•
•
Complies with the latest Category 6 standards
Screened and Unscreened versions
Easy termination without punchdown tool
Keystone format.
Description
Application
The Nexans Essential-6 keystone connectors are manufactured and tested to the
latest Category 6 specications. They support Class E applications up to 250
MHz. When installed in conjunction with Essential-6 cable and patch panels, a 25
year Class E Link Warranty can be obtained from the Nexans web site.
Design
The Essential-6 keystone connectors are designed to match with Essential-6
cable and patch cords and complement all Essential modular components, such
as:
• keystone patch panels (black and white)
• keystone outlet modules (UK, US and European formats)
Please follow the links on this page to view the related datasheets.
The modular jack is designed for keystone footprints of 14.78mm width,
20-20.78mm height and 1.5mm wall thickness and is compatible with a variety of
keystone formatted structural hardware. (Please check compatibility with Nexans
before using 3rd party hardware)
The Essential-6 connectors can be used with all types of Category 6 cable with
solid wire from 24 to 22 AWG.
Performance
The Essential-6 keystone connectors are compliant with the specications of ISO/
IEC 11801 and EN 50173.
Standards
International ISO/IEC 11801
Installation
The wire organiser guarantees fast and easy termination of the Essential-6
keystone connector without the need for a punchdown tool. An optional comfort
tool (N420.567) can be used to increase the ease of installation.
•
•
•
•
Fast and easy termination without punchdown tool.
Wiring according to colour code T568B or T568A.
Accepts 24, 23 and 22 AWG solid core cables.
Fits Nexans hardware designed for keystone format
03/12/10 - http://www.nexans.co.uk
Page 71 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Keystone Connector
Product List
Nexans ref.
N420.136
New
N420.126
New
N420.116
Name
Essential-6 Keystone Connector Screened
Essential-6 Keystone Connector Screened No Rear Cover
Essential-6 Keystone Connector Unscreened
= Make to order,
= Make to stock
Channel Performance
Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel.
Frequency MHz
Insertion Loss NEXT PP PS NEXT
ACR
PS ACR ELFEXT PSELFEXT Return Loss
dB/100m
dB
dB
dB/100m dB/100m dB/100m dB/100m
dB
1
4.0
65.0
62.0
65.0
62.0
63.3
60.3
19.0
4
4.2
63.0
60.5
58.9
56.4
51.2
48.2
19.0
10
6.6
56.6
54.0
50.0
47.4
43.3
40.3
19.0
16
8.3
53.2
50.6
44.9
42.3
39.2
36.2
18.0
20
9.3
51.6
49.0
42.3
39.7
37.2
34.2
17.5
31.25
11.7
48.4
45.7
36.7
34.0
33.4
30.4
16.5
62.5
16.9
43.4
40.6
26.5
23.7
27.3
24.3
14.0
100
21.7
39.9
37.1
18.2
15.4
23.3
20.3
12.0
155
27.6
36.7
33.8
9.1
6.2
19.5
16.5
10.1
200
31.7
34.8
31.9
3.1
0.1
17.2
14.2
9.0
250
35.9
33.1
30.2
-2.8
-5.8
15.3
12.3
8.0
All values are specied at 20°C.
03/12/10 - http://www.nexans.co.uk
Page 72 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Patch Panels
• Complies to the latest Category 6 standard
• Punchdown from the top or the rear side
• Unshielded
Description
Application
The Nexans Essential-6 patch panels are based on 19" frame dimensions and
have 24 Category 6 RJ45 ports on 1HU. They support Class E applications up to
250 MHz. When the panels are installed in conjunction with Essential-6 cable and
outlets, a 20 year Class E Link Certicate can be obtained from the Nexans eservice site.
Design
The Essential-6 patch panels are compatible with the complete Essential-6 range
and can be used with all types of UTP Category 6 cable with solid wire from 22 to
24 AWG. The panels are available in either black or grey-white nish.
Performance
The Essential-6 patch panels are compliant with the specications of ISO/IEC
11801:2002.
Installation
• Fast and easy termination of IDC blocks by LSA+ punchdown tooling.
• Colour code T568A and T568B (Product dependent).
• Supplied with xings and tie-wraps.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 73 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Patch Panels
Product List
Nexans ref.
N424.610
New
N424.613
New
Name
Essential-6 Patch panel 1HU 24 Cat 6 ports, rear connection, black
Essential-6 Patch panel 1HU 24 Cat 6 ports, top connection, black
= Make to order,
= Make to stock
Channel Performance
Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel.
Frequency MHz
Insertion Loss NEXT PP PS NEXT
ACR
PS ACR ELFEXT PSELFEXT Return Loss
dB/100m
dB
dB
dB/100m dB/100m dB/100m dB/100m
dB
1
4.0
65.0
62.0
65.0
62.0
63.3
60.3
19.0
4
4.2
63.0
60.5
58.9
56.4
51.2
48.2
19.0
10
6.6
56.6
54.0
50.0
47.4
43.3
40.3
19.0
16
8.3
53.2
50.6
44.9
42.3
39.2
36.2
18.0
20
9.3
51.6
49.0
42.3
39.7
37.2
34.2
17.5
31.25
11.7
48.4
45.7
36.7
34.0
33.4
30.4
16.5
62.5
16.9
43.4
40.6
26.5
23.7
27.3
24.3
14.0
100
21.7
39.9
37.1
18.2
15.4
23.3
20.3
12.0
155
27.6
36.7
33.8
9.1
6.2
19.5
16.5
10.1
200
31.7
34.8
31.9
3.1
0.1
17.2
14.2
9.0
250
35.9
33.1
30.2
-2.8
-5.8
15.3
12.3
8.0
All values are specied at 20°C.
03/12/10 - http://www.nexans.co.uk
Page 74 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Outlet Modules
•
•
•
•
•
•
Complies to the latest Category 6 standards
Includes 25x50, LJ6C and 50x50 triple modules
Unshielded
LSA+ termination
UK white
Fits in all Nexans UK structural hardware
Description
Application
The Nexans Essential-6 unshielded outlet modules are manufactured and tested
to the latest Category 6 specications. They support Class E applications up to
250 MHz. When installed in conjunction with Essential-6 cable and patch panels,
a 25 year Class E Link Certicate can be obtained from the Nexans e-service site.
Design
The Essential-6 outlet modules are compatible with the complete Essential-6
range and t into all Nexans UK structural hardware. They can be used with all
types of UTP Category 6 cable with solid wire from 22 to 24 AWG. The spring
shuttered modules come in glossy white nish, matching with most British style
structural hardware. They are available in different versions:
•
•
•
•
single module 25x50mm
single module 25x50mm - low prole
triple module 50x50mm
LJ6C module 25x37mm
The modules are equipped with transparent label holders tted with a blank paper
label for customised port identication.
Performance
The Essential-6 outlet modules are compliant with the specications of ISO/IEC
11801: 2002.
Installation
Standards
•
•
•
•
•
•
International ISO/IEC 11801
Fast and easy termination by LSA+ punch-down tooling.
Wiring according to colour code T568B.
Centrally positioned tie wrap bridges ensure cable strain relief.
Supplied with tie wraps.
Labelling windows included.
Fits in all Nexans UK structural hardware
03/12/10 - http://www.nexans.co.uk
Page 75 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Outlet Modules
Product List
Nexans ref.
N424.623
N424.621
N424.620
New
N424.622
To be removed
Name
Essential-6 LJ6C outlet module 25x39.5mm
Essential-6 single outlet module 25x50mm
Essential-6 single outlet module 25x50mm - Low Prole
Essential-6 triple outlet module 50x50mm
= Make to order,
= Make to stock
Channel Performance
Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel.
Frequency MHz
Insertion Loss NEXT PP PS NEXT
ACR
PS ACR ELFEXT PSELFEXT Return Loss
dB/100m
dB
dB
dB/100m dB/100m dB/100m dB/100m
dB
1
4.0
65.0
62.0
65.0
62.0
63.3
60.3
19.0
4
4.2
63.0
60.5
58.9
56.4
51.2
48.2
19.0
10
6.6
56.6
54.0
50.0
47.4
43.3
40.3
19.0
16
8.3
53.2
50.6
44.9
42.3
39.2
36.2
18.0
20
9.3
51.6
49.0
42.3
39.7
37.2
34.2
17.5
31.25
11.7
48.4
45.7
36.7
34.0
33.4
30.4
16.5
62.5
16.9
43.4
40.6
26.5
23.7
27.3
24.3
14.0
100
21.7
39.9
37.1
18.2
15.4
23.3
20.3
12.0
155
27.6
36.7
33.8
9.1
6.2
19.5
16.5
10.1
200
31.7
34.8
31.9
3.1
0.1
17.2
14.2
9.0
250
35.9
33.1
30.2
-2.8
-5.8
15.3
12.3
8.0
All values are specied at 20°C.
03/12/10 - http://www.nexans.co.uk
Page 76 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Patch Cords
•
•
•
•
•
Comply with latest Category 6 standards
Screened and unscreened
Light grey PVC
Light grey slimline boot with bend relief
1, 2, 3 and 5m lengths
Description
Application
The Nexans Essential-6 patch cords are manufactured and tested to the latest
Category 6 specications and support Class E applications up to 250 MHz. They
are matched with the complete Essential-6 range in order to deliver a full end-toend Class E Channel.
Design
The Essential-6 patch cords contain a central PE cross member, keeping the
pairs in place and reducing the risk of losing performance when bending the
cords. Available in standard lengths of 1, 2, 3 and 5m, each cord is individually
bagged and carries a traceability code.
Performance
The Essential-6 cords are compliant with the specications of ISO/IEC 11801 and
EN 50173.
Installation
Thanks to their small outer diameter, the Essential-6 cords are as easy to install
and manage in a rack as their Cat 5e equivalent.
Standards
International ISO/IEC 11801
Flame retardant
IEC 60332-1
03/12/10 - http://www.nexans.co.uk
Page 77 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Patch Cords
Characteristics
Electrical characteristics
Characteristic impedance
Usage characteristics
Range
Flame retardant
Product List
Nexans ref.
N101.12ECGG
New
N101.12EEGG
New
N101.12EFGG
New
N101.12EHGG
New
N101.21ECOO
New
N101.21EEOO
New
N101.21EFOO
New
N101.21EHOO
New
N101.11ECGG
New
N101.11EEGG
New
N101.11EFGG
New
N101.11EHGG
New
100 Ohm
essential-6
IEC 60332-1
=Make to order,
=Make to stock
Screen Length (m) Outer sheath Colour
Name
Essential-6 Patch Cord FTP Cat 6 PVC Grey 1m
FTP
1
PVC
Light grey
Essential-6 Patch Cord FTP Cat 6 PVC Grey 2m
FTP
2
PVC
Light grey
Essential-6 Patch Cord FTP Cat 6 PVC Grey 3m
FTP
3
PVC
Light grey
Essential-6 Patch Cord FTP Cat 6 PVC Grey 5m
FTP
5
PVC
Light grey
Essential-6 Patch Cord UTP Cat 6 LSZH Orange 1m
UTP
1
LSZH
Orange
Essential-6 Patch Cord UTP Cat 6 LSZH Orange 2m
UTP
2
LSZH
Orange
Essential-6 Patch Cord UTP Cat 6 LSZH Orange 3m
UTP
3
LSZH
Orange
Essential-6 Patch Cord UTP Cat 6 LSZH Orange 5m
UTP
5
LSZH
Orange
Essential-6 Patch Cord UTP Cat 6 PVC Grey 1m
UTP
1
PVC
Light grey
Essential-6 Patch Cord UTP Cat 6 PVC Grey 2m
UTP
2
PVC
Light grey
Essential-6 Patch Cord UTP Cat 6 PVC Grey 3m
UTP
3
PVC
Light grey
Essential-6 Patch Cord UTP Cat 6 PVC Grey 5m
UTP
5
PVC
Light grey
= Make to order,
= Make to stock
Channel Performance
Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel.
Frequency MHz
Insertion Loss NEXT PP PS NEXT
ACR
PS ACR ELFEXT PSELFEXT Return Loss
dB/100m
dB
dB
dB/100m dB/100m dB/100m dB/100m
dB
1
4.0
65.0
62.0
65.0
62.0
63.3
60.3
19.0
4
4.2
63.0
60.5
58.9
56.4
51.2
48.2
19.0
10
6.6
56.6
54.0
50.0
47.4
43.3
40.3
19.0
16
8.3
53.2
50.6
44.9
42.3
39.2
36.2
18.0
20
9.3
51.6
49.0
42.3
39.7
37.2
34.2
17.5
31.25
11.7
48.4
45.7
36.7
34.0
33.4
30.4
16.5
62.5
16.9
43.4
40.6
26.5
23.7
27.3
24.3
14.0
100
21.7
39.9
37.1
18.2
15.4
23.3
20.3
12.0
155
27.6
36.7
33.8
9.1
6.2
19.5
16.5
10.1
200
31.7
34.8
31.9
3.1
0.1
17.2
14.2
9.0
250
35.9
33.1
30.2
-2.8
-5.8
15.3
12.3
8.0
03/12/10 - http://www.nexans.co.uk
Page 78 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-6 Patch Cords
All values are specied at 20°C.
03/12/10 - http://www.nexans.co.uk
Page 79 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Category 7 / 7A
LANmark-7 is the highest performance standards compliant, copper solution
available in the market. This Category 7 / Class F solution provides backwards
compatible performance beyond 600MHz and features the revolutionary GG45
connector.
Recommended uses:
• Very long lifetime needs (>15years)
• Composite analogue & high speed digital data
• Multiple service applications (voice, data, video using different pairs in the
same cable)
• Very high electromagnetic noise environments
• Installations where the relacement cost is very high (e.g. ships etc)
03/12/10 - http://www.nexans.co.uk
Page 80 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Cable
•
•
•
•
Exceeds Category 7 using 4 individually screened pairs
Optimised for use with LANmark-7 GG45 connector
Small outer diameter
Easy to install due to a tight foil construction
Description
Description
LANmark-7 cable is a 4pr S/FTP with individual pair foils and an overall braid
offering superior performance in terms of ACR. It is fully compliant with the
Category 7 standards and when installed together with the GG45 LANmark-7
connector as a system is guaranteed to exceed all channel requirements in all
conguration scenarios (up to 4-connector channels).
Application
LANmark-7 will support all current and planned data applications developed for
cabling up to Class F.
•
•
•
•
•
•
All Ethernet applications including
1000Base-T
1000Base-TX
10GBase-T
CATV up to 862MHz
Any future Class F application
Installation
Ease of Installation is one of the unique features of LANmark-7 cable. Extra
attention has been paid to ensure screen coverage is maintained both during and
after installation. The cable has been designed specically to offer both optimum
performance and ease of termination when used in conjunction with the
LANmark-7 GG45 connector.
03/12/10 - http://www.nexans.co.uk
Standards
International EN 50173;
EN 50288-4-1; ISO/IEC 11801; ISO/
IEC 61156-5
Page 81 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Cable
Characteristics
Transmission characteristics
Velocity of propagation
Product List
Nexans ref.
N100.376
N100.365
New
N100.367
New
80.0 %
=Make to order,
=Make to stock
Type of cable Category
S/FTP
Cat. 7
Name
LANmark-7 Lloyd's S/FTP Cat 7 23 AWG LSZH Blue 500m Reel
LANmark-7 S/FTP Cat 7 600MHz 23 AWG LSZH Orange 1000m Reel
S/FTP
Cat. 7
LANmark-7 S/FTP Cat 7 600MHz Dual 2x23AWG LSZH Orange 500m Reel S/FTP Shotgun
= Make to order,
Cat. 7
= Make to stock
Electrical Performance LANmark-7 600 S/FTP Cable
Electrical Performance LANmark-7 600 S/FTP Cable
Attenuation
Frequency (dB/100m)
(MHz)
NEXT
ACR
PS-NEXT
ACR-F
PS-ACR-F
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
Min.
Typ.
Min.
Typ.
Min.
Typ.
Min.
Typ.
Min.
Return Loss
(in dB)
Max.
Typ.
Typ.
Min.
Typ.
1.00
4.0
1.8
75.0
100.0
71.0
98.2
72.0
98.0
75.0
98.0
75.0
96.0
20.0
4.00
4.0
3.5
75.0
100.0
71.0
96.5
72.0
98.0
75.0
98.0
75.0
96.0
23.0
26.0
10.00
5.9
5.5
75.0
100.0
69.1
94.5
72.0
98.0
75.0
98.0
72.3
96.0
25.0
28.0
16.00
7.4
6.8
75.0
100.0
67.6
93.2
72.0
98.0
71.2
96.0
68.2
94.0
25.0
28.0
20.00
8.3
7.7
75.0
100.0
66.7
92.3
72.0
98.0
69.3
94.0
66.3
92.0
25.0
28.0
31.25
10.4
9.6
75.0
100.0
64.6
90.4
72.0
98.0
65.4
90.0
62.4
88.0
23.6
26.0
62.50
14.9
14.0
75.0
100.0
60.1
86.0
72.0
98.0
59.4
84.0
56.4
82.0
21.5
25.0
100.00
19.0
17.7
72.4
100.0
53.4
82.3
69.4
98.0
55.3
75.0
52.3
73.0
20.1
24.0
155.00
24.0
22.8
69.5
96.0
45.6
73.2
66.5
93.0
51.5
70.0
48.5
68.0
18.8
23.0
250.00
31.0
29.0
66.4
94.0
35.5
65.0
63.4
91.0
47.3
66.0
44.3
64.0
17.3
22.0
300.00
34.2
32.1
65.2
92.0
31.1
59.9
62.2
88.0
45.8
54.0
42.8
52.0
17.3
20.0
600.00
50.1
45.5
60.7
90.0
10.6
44.5
57.7
86.0
39.7
54.0
36.7
52.0
17.3
20.0
all values are specied at 20°C
03/12/10 - http://www.nexans.co.uk
Page 82 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 GG45 Connector
LANmark-7 GG45
•
•
•
•
•
•
•
•
High speed ‘2 in 1’ Multimedia Connector
Supports data applications up to 600 MHz Class F
Supports CATV VHF and UHF up to 1000MHz
Backwards compatible
Switch Inside
Compatible with ISO 11801 (enterprise cabling)
Compatible with ISO 15018 (residential cabling)
Fits in all Nexans modular Snap-In structural hardware
Description
Description
LANmark-7 GG45 is a standardised High Speed ‘2 in 1’ Snap-In Connector, which
contains a full Cat 6 (RJ45) Interface as well as a full Cat 7 Interface, using
additional contacts for the 600 MHz transmission.
LANmark-7 offers uniquely backwards compatible services realised through an
incorporated switch, which activates a maximum of 8 out of 12 contacts. For
100/250 MHz transmission performance, the upper 8 RJ45 contacts are used, for
600 MHz the 8 contacts in the extreme corners are used.
The LANmark-7 GG45 Snap-In Connector is part of the Nexans modular Snap-In
system and ts in all structural hardware designed for this range. It is a fullscreened connector with 360° EMC protection. 4 versions of LANmark-7 GG45
are available: one for solid cables, one for stranded cables, a UL version and a
Heavy Duty connector for harsh environments. The version of GG45 for stranded
wire is especially made for networks, which use 3/4 Connector Links and so
called Consolidation Points to achieve higher exibility. GG45 for stranded wire
can terminate single ended exible patch cords at those Consolidation Points.
An optional adapter clip can be added to t the outer dimensions of the
international well-known keystone format.
Standards
Application
International ISO/IEC 11801
LANmark-7 GG45 supports all data applications dened for Cat 5, Cat 5E, Cat 6
and Cat 7 such as 10BaseT, 100BaseT, Gigabit Ethernet, 1000BaseTX,
1GBaseTX2 over Class F, 1GBaseTX4 over Class F, 10GBaseT according
IEEE802.3.AN, 155 ATM, 622 ATM, 1G ATM (CB1G) ..... .
Performance
The LANmark-7 GG45 Snap-In Connector has been designed to reach the
highest performance in Cat 6, Cat 7 and broadcast applications (as for example
ISO 15018 residential cabling). It has outstanding performance for attenuation
(insertion loss), NEXT/FEXT, Power Sum NEXT/FEXT and RETURN LOSS. A
metal cross inside the connector ensures the high NEXT performance in Cat 6
and Cat 7 mode. Excellent Return Loss Values ensure that LANmark-7 GG45 in
addition to all Data applications is best suited to support CATV signals up to 1000
MHz.
Product List
Nexans ref.
N420.730
N420.731
=Make to order,
=Make to stock
Name
LANmark-7 GG45 12C Snap-In Connector Cat 7 600MHz Screened
LANmark-7 GG45 12C Snap-In Connector Cat 7 600MHz Screened for stranded wire
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 83 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 GG45 Connector
Selling delivery information
Guarantees
The LANmark-7 GG45 Snap-In Connector is fully compliant with the current ISO Cat 6 and Cat 7 standard and exceeds all
parameters with substantial headroom.
When combined with LANmark Cat 6 or Cat 7 Cables and Patch Cords a full 25 year Class E and F Channel Warranty can
be obtained.
Installation
The LANmark-7 GG45 Snap-In connector is designed to be terminated without punch down tools. For fast and easy
installation of large volumes, an optional Comfort Tool can be used.
•
•
•
•
Versions for solid cable: accepts 24, 23 and 22 AWG cable
Version for stranded cable: accepts 26 AWG ex cable
Fast termination of cable using Nexans wire organiser
Colour code : TSB568A and TSB568B
03/12/10 - http://www.nexans.co.uk
Page 84 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
GG45 8C PCB jack
LANmark-7 GG45
•
•
•
•
•
Right angled Cat 7A PCB jack up to 1500 MHz
to be used in active equipment or patch panels
UL94-V0 plastic components
RoHS compliant
Wave solder compatible.
Description
Please refer to the datasheet of N420.738 for more detailed information and
performance tables.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 85 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
GG45 8C PCB jack
Characteristics
Construction characteristics
Colour
Screen
Connector type
Dimensional characteristics
Height
Width
Depth
Usage characteristics
Component function
Product List
Nexans ref.
N420.738
New
Black
Yes
Female
13.5 mm
15.24 mm
21.84 mm
Connector
Name
GG45 Right angle 8 contact jack for PCB mount
Category
Range
Cat. 7A
LANmark-7A
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 86 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Patch Cords
Nexans Cat 7 Patch Cords
•
•
•
•
•
High speed multimedia patch cord
600 MHz according IEC61076-3-110
Allow full 4-connector Class F channels
Compatible with ISO 11801 (Ofce environment)
Compatible with ISO 15018 standard (Residential environment)
Description
Application
Nexans LANmark-7 patch cords with GG45 non switched plugs enable a GG45
permanent link to be used in 600 MHz mode. The protruding part on the plug
activates the switch within the GG45 jack and terminates the not used contacts of
RJ45 to ground. Using the contacts in the extreme outer corners of the RJ45
interface for transmission, excellent NEXT and Return Loss performance are
achieved.
Nexans LANmark-7 patch cords maximise the full performance of the channel
and will exceed the requirements of the ISO 4 connector model. This provides
improved data throughput up to 600 MHz and allows for the inclusion of additional
patching or Consolidation Points for maximum system exibility and all future data
applications according ISO 11801.
• High Speed Multimedia patch cords
• Screened
• 2 x GG45 4-pair, non backwards compatible plugs
Guarantees
•
•
•
•
Reliable connections over the lifetime of the cabling system.
Compatible with IEC 61076-3-110
Compatible with Class F standard (ISO 11801)
Compatible with Residential standard (ISO 15018) for BCT applications
Standards
International ISO/IEC 11801
Installation
• Rugged construction
- high connector retention force due to moulded connectors
- external strain relief
- self-latching, high reliability GG45 (IEC61076-3-110) screened connectors
- sidebars on the plug avoid errors by using the patch cord for RJ45 jacks
• A Low Smoke Zero Halogen - Flame Retardant jacket is standard
• Orange is standard, different colors are available on request, subject to quantity
and availability
• 1, 2, 3 and 5m are standard lengths, others lengths are available on demand
Fire retardant
IEC 60332 Part 1
03/12/10 - http://www.nexans.co.uk
Page 87 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Patch Cords
Characteristics
Construction characteristics
Outer sheath
Colour
Electrical characteristics
Characteristic impedance
Usage characteristics
Fire retardant
LSZH-FR
Orange
100 Ohm
IEC 60332 Part 1
Product List
Nexans ref. Name
N900.679
N101.239EO
N101.239FO
N101.239HO
N101.269OO
=Make to order,
=Make to stock
Mechanical durability/ Length Nominal outer
Range
matings
(m)
diameter (mm)
LANmark-7 Measurement Cord Cat 7
GG45 4P/GG45 4P LSZH-FR SCR 2
M ORANGE
LANmark-7 Patch Cord Cat 7 GG45
4P/GG45 4P LSZH FR SCR 2 M
ORANGE
LANmark-7 Patch Cord Cat 7 GG45
4P/GG45 4P LSZH-FR SCR 3 M
ORANGE
LANmark-7 Patch Cord Cat 7 GG45
4P/GG45 4P LSZH-FR SCR 5 M
ORANGE
LANmark-7 Single End Cord Cat 7
GG45 4P LSZH-FR SCR 10 M
ORANGE
1000
2
6.35
LANmark-7
750
2
6.35
LANmark-7
750
3
6.35
LANmark-7
750
5
6.35
LANmark-7
750
10
6.35
LANmark-7
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 88 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Splitter Cords
•
•
•
•
Patch cords to allow application sharing with GG45
Up to 4 applications simultaneously
Compatible with ISO 11801
Compatible with ISO 15018 draft
Description
Application
LANmark-7 Splitter cords allow to run multiple applications at the same time using
only 1 GG45 permanent link.
LANmark-7 cable provides 4 individually shielded cable pairs . The GG45
Connector maintains the individual shields due to its internal metal cross and
creates 4 completely shielded end to end communications channels, which can
be used by different applications simultaneously. The LANmark-7 splitter cords
allow to address each communication channel individually.
Many applications do not use all 4-pairs provided by the cable. Analogue
telephony and CATV for example need only 1 pair, many data protocols like
Ethernet and Fast Ethernet use 2 pairs.
Broadband Applications supported
LANmark-7 systems support CATV/CCTV applications and comply with the
requirement for BCT in the ISO15018 Draft for Home Applications. Each of the 4
communication channels supports the CATV/CCTV applications up to 1000MHZ.
Up to the maximum of 4 pairs different combinations are supported:
• 4 services : eg. 4 x 1 pair applications such as voice, fax, CATV/CCTV
• 3 services: eg. 2 x 1 pair applications plus 1 x 2 application such as Ethernet or
Fast Ethernet
• 2 services: eg. 2 x 2 pair applications
• 1 service: eg. 1 x 4 pair application such as Gigabit Ethernet
Standards
International ISO/IEC 11801
Description
The patch cords always have 1 GG45 Plug on the wall outlet side and multiple
connectors on the user side. The GG45 Plugs terminates up to 3 cables, held
together by a molded boot. On the user side the patch cords use standard RJ45
or RJ11 connectors.
Guarantees
• Reliable connections with LANmark-7 GG45 and User Terminals
• up to 750 insertions
• Compatible with IEC 61076-3-110 and IEC 60603-7 series
Properties
• Grey Color
Flame retardant
IEC 60332-1
03/12/10 - http://www.nexans.co.uk
Page 89 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7 Splitter Cords
Characteristics
Construction characteristics
Outer sheath
Sheath colour
Electrical characteristics
Characteristic impedance
Usage characteristics
Mechanical durability/matings
Range
Flame retardant
Product List
Nexans ref.
N101.2B9CG
New
N101.2B9EG
New
N101.2B9FG
New
N101.2B9HG
New
N101.2A9CG
New
N101.2A9EG
New
N101.2A9FG
New
N101.2A9HG
New
LSZH-FR
Light grey
100 Ohm
750
LANmark-7
IEC 60332-1
=Make to order,
Name
=Make to stock
Length (m)
Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 1m LSZH Grey
1
Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 2m LSZH Grey
2
Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 3m LSZH Grey
3
Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 5m LSZH Grey
5
Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 1m LSZH Grey
1
Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 2m LSZH Grey
2
Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 3m LSZH Grey
3
Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 5m LSZH Grey
5
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 90 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A Cable
•
•
•
•
•
Exceeds Category 7A in terms of ACR and Frequency Range
Suitable for channels with capacity above 40GBps over 100m
Superior Performance with positive ACR over the full frequency range
Optimised for use with LANmark-7A GG45 connector
Easy to install with Cat 7 connectivity through special foil construction
Description
Description
LANmark-7A is a 4 pair S/FTP cable with individual pair foils and an overall braid
offering superior performance up to 1200MHz. It is fully compliant with the new
Category 7A standard and offers even large headroom above the Cat 7A
requirement. Due to this excellent electrical performance and positive ACR up to
1000 / 1200MHz the cable is suited for transmission channels with a capacity of
>40Gbps over 100m.
Application
LANmark-7A is the highest performing standardised cabling solution in the market
and will support all current data applications and all planned applications using
cabling up to Class FA (see discussions at IEEE about 40/100Gbps).
•
•
•
•
•
•
•
All Ethernet applications including
10/100/1000Base-T
1000Base-TX
10GBase-T
CaTV up to 862MHz
Cable sharing applications including CATV
Any future Class FA application
Standards
International EN 50173;
EN 50288-4-1; ISO/IEC 11801; ISO/
IEC 61156-5
Installation
Ease of Installation is one of the main features of the LANmark-7A cable. Extra
attention has been paid to ensure that the screen coverage is maintained and
foils do not open during installation. The cable has been specially designed to be
used in conjunction with the LANmark-7A GG45 12C connector.
03/12/10 - http://www.nexans.co.uk
Page 91 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A GG45 Connector
LANmark-7A GG45
•
•
•
•
•
•
•
First RJ45-compatible Cat 7A connector using Nexans unique GG45 interface
Able to support future 40Gigabit Ethernet application
Able to provide Shannon Capacity of 50Gbps over 100m
Full Class FA channel compliancy according to ISO11801 Amendment 1
Fully screened for Alien Crosstalk Immunity
”2 in 1” Connector using 12 contacts to run 2 separate transmission modes
Compatible with all Snap-In panels and outlets
Description
Description
LANmark-7A GG45 is a screened RJ45-compatible cable jack specied up to
1000MHz. It is designed specically to support the high frequencies required for
applications beyond 10 Gigabit Ethernet. Combined with LANmark7A Cable and
Patch Cords, LANmark-7A GG45 has double the frequency range and half of the
crosstalk compared to Cat6A and provides excellent transmission capacity up to
50Gbps over 100m (4-times of Cat6A). LANmark-7A GG45 uses 12 contacts: 8
contacts for the 1200MHz transmission (GG-mode) and 4 additional contacts to
ensure RJ45 compatibility (RJ Mode). Thanks to its 360° screening and a fully
closed rear cover, the connector allows excellent coupling attenuation and
ensures immunity from alien crosstalk and other external interference. The
LANmark-7A GG45 connector ts in all structural hardware designed for the
Snap-In Connectors and can be used in all positions of a 4 connector twisted pair
cabling channel (PP, CC, CP, TO).
Applications
•
•
•
•
•
•
•
•
•
•
10Base-T Ethernet
100Base-TX Fast Ethernet
1000Base-TX Gigabit Ethernet
10GBase-T 10 Gigabit Ethernet IEEE 802.3
155 Mbit ATM
1.2 Gbit ATM
CATV up to 862MHz
all future Cat 6A and Class EA applications
all future Cat 7 and Class F applications
all future Cat 7 and Class FA applications
Standards
International EN 50173-1;
IEC 60603-7-5; ISO/IEC 11801
Performance
The LANmark-7A GG45 12C Snap-In Connector is the rst RJ45 compatible
which meets the stringent requirements of Cat 7A up to 1000MHz. It has
outstanding performance for Insertion Loss, Return Loss, NEXT/FEXT, Power
Sum NEXT/FEXT, and especially Alien Crosstalk.
When used in combination with Nexans LANmark-7A cables and LANmark-7A
patch cords, the four-connector channel meets Class FA requirements as dened
in ISO/IEC11801 amendment 1.
Installation
The LANmark-7A GG45 12C Snap-In Connector makes use of Nexans wire
organiser and is therefore very easy and fast to terminate. Using the Nexans
patented Easy Termination Tool for GG45 the termination of GG45 is fool-proof
and very reliable. A stranded version is available to allow the use of exible
stranded cable in cross connects or consolidation points.
03/12/10 - http://www.nexans.co.uk
Page 92 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A GG45 Connector
•
•
•
•
•
•
•
•
Fast termination with exclusive wire organizer
Colour code : T568A &T568B
360° EMC protection
Accepts solid wire from 22 to 24 AWG
Stranded version available for consolidation point
Snap-in format ts in all Nexans structural hardware
2 possibilities to terminate the drain wire : on the housing or on the rear cover
Can be turned into keystone format using additional adapter
Guarantees
The LANmark-7A GG45 12C Snap-In Connector is covered by the guarantee as
described in “The General Terms and Conditions of Sales”. When installed in
combination with other LANmark-7A components, a 25 years channel warranty
can be obtained, covering full Cat 7A/Class FA compliance.
03/12/10 - http://www.nexans.co.uk
Page 93 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A GG45 Connector
Product List
Nexans
ref.
N420.735
N420.736
Name
Height
(mm)
Width
(mm)
Depth
(mm)
19.5
17
41.4
19.5
17
41.4
LANmark-7A GG45 12C Snap-In Connector Cat 7A 1000MHz
Screened
LANmark-7A GG45 12C Snap-In Connector Cat 7A 1000MHz
Screened for stranded wire
= Make to order,
= Make to stock
Electrical Performance LANmark-7A
Typical Data given for Worst Case 4-Connector Channel Congurations
Attenuation
NEXT pp
ACR-F
RL
Coupling Att.
PSANEXT
PSAFEXT
Frequency
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in MHz)
Max Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
1
4.0
3.6
65.0
104.8
65.0
70.0
19.0
38.0
80.0
106.0
67.0
82.0
80.0
95.0
4
4.1
3.7
65.0
94.6
65.0
70.0
19.0
32.0
68.0
94.0
67.0
82.0
79.8
94.8
10
6.4
5.7
65.0
87.8
65.0
70.0
19.0
28.0
60.0
86.0
67.0
82.0
75.9
90.9
16
8.0
7.2
65.0
84.2
63.3
68.3
18.0
26.0
55.9
81.9
67.0
82.0
73.9
88.9
20
9.0
8.1
65.0
82.5
61.4
66.4
17.5
25.0
54.0
80.0
67.0
82.0
72.9
87.9
31.25
11.2
10.1
65.0
79.1
57.5
62.5
16.5
23.1
50.1
76.1
67.0
82.0
71.0
86.0
62.5
15.9
14.3
65.0
73.7
51.5
56.5
14.0
20.0
44.1
70.1
67.0
82.0
68.0
83.0
100
20.3
18.2
65.0
70.0
47.4
52.4
12.0
18.0
40.0
66.0
67.0
82.0
65.9
80.9
155
25.4
22.8
63.0
66.6
43.6
48.6
10.1
16.1
36.2
62.2
67.0
82.0
63.9
78.9
200
28.9
26.0
60.9
64.6
41.4
46.4
9.0
15.0
34.0
60.0
67.0
82.0
62.8
77.8
250
32.5
29.2
59.1
62.8
39.4
44.4
8.0
14.0
32.0
58.0
67.0
82.0
61.8
76.8
300
35.7
32.1
57.7
61.3
37.8
42.8
8.0
13.2
30.5
56.5
67.0
82.0
60.9
75.9
500
46.7
42.0
53.6
57.2
33.4
38.4
8.0
11.0
26.0
52.0
64.5
79.5
58.6
73.6
600
51.4
46.3
52.1
55.8
31.8
36.8
8.0
10.2
24.4
50.4
63.3
78.3
57.8
72.8
700
55.8
50.2
50.8
54.5
30.5
35.5
7.5
9.5
23.1
49.1
62.3
77.3
57.1
72.1
800
59.9
53.9
49.7
53.5
29.3
34.3
7.0
9.0
21.9
47.9
61.5
76.5
56.4
71.4
900
63.8
57.5
48.8
52.5
28.3
33.3
6.5
8.5
20.9
46.9
60.7
75.7
55.9
70.9
1000
67.6
60.8
47.9
51.6
27.4
32.4
6.0
8.0
20.0
46.0
60.0
75.0
55.4
70.4
all values are specied at 20°C
03/12/10 - http://www.nexans.co.uk
Page 94 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A Patch Cord
LANmark-7A GG45 Patchcords
•
•
•
•
•
High bandwidth patch cord for 40 Gigabit applications and beyond
Runs the GG45 '2in1' Connector in its high speed GG-Mode
Both Sides use GG45 8 Contact Plugs up to 1000 MHz according IEC61076-3-110
Allow full 4-connector Class FA channels
Compatible with High Density requirements in Data Centres
Description
Description
Nexans LANmark-7A patch cords with GG45 8C non-switched plugs enable a
GG45 7A permanent link to be used in 1000 MHz mode. The protruding part on
the plug activates the switch within the GG45 7A “2in1” jack and terminates the
none used contacts of RJ45 to ground. Using the contacts in the extreme outer
corners of the RJ45 interface for transmission, excellent NEXT and Return Loss
performances are achieved.
Nexans LANmark-7A patch cords maximise the full performance of the channel
and will exceed the requirements of the ISO 4 connector model. This provides
improved data throughput up to 1000 MHz and allows for the inclusion of
additional patching or Consolidation Points for maximum system exibility and all
future data applications according ISO 11801.
• High Speed patch cords
• Screened
• 2 x GG45 8C 4-pair
Guarantees
• Reliable connections over the lifetime of the cabling system.
• Compatible with IEC 61076-3-110
• Compatible with Class F and Class FA standards (ISO 11801:2008)
Standards
International ISO/IEC 11801
Installation
•
•
•
•
•
•
Look and Feel of a RJ45 plug (just using different contact positions)
Self-latching, high reliability GG45 (IEC61076-3-110) screened connectors
Sidebars on the plug avoid errors by using the patch cord for RJ45 jacks
Low Smoke Halogen Free - Flame Retardant cable jacket
Orange color, different colors available on request
1, 2, 3 and 5m lengths, others lengths available on request
03/12/10 - http://www.nexans.co.uk
Page 95 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-7A Patch Cord
Characteristics
Construction characteristics
Colour
Product List
Nexans ref.
N900.67A
New
N101.23AOO
New
N101.23ARO
New
N101.23AEO
New
N101.23AFO
New
N101.23AHO
New
Orange
=Make to order,
=Make to stock
Name
CAT7A Measurement Cord GG45 8C LSZH Orange 2m
LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 10m
LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 20m
LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 2m
LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 3m
LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 5m
= Make to order,
= Make to stock
Electrical Performance LANmark-7A
Typical Data given for Worst Case 4-Connector Channel Congurations
Attenuation
NEXT pp
ACR-F
RL
Coupling Att.
PSANEXT
PSAFEXT
Frequency
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in dB)
(in MHz)
Max Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
Min
Typical
1
4.0
3.6
65.0
104.8
65.0
70.0
19.0
38.0
80.0
106.0
67.0
82.0
80.0
95.0
4
4.1
3.7
65.0
94.6
65.0
70.0
19.0
32.0
68.0
94.0
67.0
82.0
79.8
94.8
10
6.4
5.7
65.0
87.8
65.0
70.0
19.0
28.0
60.0
86.0
67.0
82.0
75.9
90.9
16
8.0
7.2
65.0
84.2
63.3
68.3
18.0
26.0
55.9
81.9
67.0
82.0
73.9
88.9
20
9.0
8.1
65.0
82.5
61.4
66.4
17.5
25.0
54.0
80.0
67.0
82.0
72.9
87.9
31.25
11.2
10.1
65.0
79.1
57.5
62.5
16.5
23.1
50.1
76.1
67.0
82.0
71.0
86.0
62.5
15.9
14.3
65.0
73.7
51.5
56.5
14.0
20.0
44.1
70.1
67.0
82.0
68.0
83.0
100
20.3
18.2
65.0
70.0
47.4
52.4
12.0
18.0
40.0
66.0
67.0
82.0
65.9
80.9
155
25.4
22.8
63.0
66.6
43.6
48.6
10.1
16.1
36.2
62.2
67.0
82.0
63.9
78.9
200
28.9
26.0
60.9
64.6
41.4
46.4
9.0
15.0
34.0
60.0
67.0
82.0
62.8
77.8
250
32.5
29.2
59.1
62.8
39.4
44.4
8.0
14.0
32.0
58.0
67.0
82.0
61.8
76.8
300
35.7
32.1
57.7
61.3
37.8
42.8
8.0
13.2
30.5
56.5
67.0
82.0
60.9
75.9
500
46.7
42.0
53.6
57.2
33.4
38.4
8.0
11.0
26.0
52.0
64.5
79.5
58.6
73.6
600
51.4
46.3
52.1
55.8
31.8
36.8
8.0
10.2
24.4
50.4
63.3
78.3
57.8
72.8
700
55.8
50.2
50.8
54.5
30.5
35.5
7.5
9.5
23.1
49.1
62.3
77.3
57.1
72.1
800
59.9
53.9
49.7
53.5
29.3
34.3
7.0
9.0
21.9
47.9
61.5
76.5
56.4
71.4
900
63.8
57.5
48.8
52.5
28.3
33.3
6.5
8.5
20.9
46.9
60.7
75.7
55.9
70.9
1000
67.6
60.8
47.9
51.6
27.4
32.4
6.0
8.0
20.0
46.0
60.0
75.0
55.4
70.4
all values are specied at 20°C
03/12/10 - http://www.nexans.co.uk
Page 96 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Modular Patch Panels
03/12/10 - http://www.nexans.co.uk
Page 97 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Snap-In Patch Panels
•
•
•
•
•
•
•
Compatible with all Snap-In connectors
24 ports
Sliding and Fixed versions available
Clip-On mechanism
Exclusive Auto-Connect Earthing system
Universal design supporting Unscreened and Screened connectors
Shuttered versions available
Description
Nexans Snap-In range of patch panels are designed to accomodate any of the
Snap-In connectors in the LANmark product family (LANmark-7A, LANmark-6A,
LANmark-6, and LANmark-5).
The Snap-In panels feature an exclusive Clip-On system to secure the connector
in the panel and to provide a simple means of earthing shielded connectors
to facilitate installation. Connection of the panel to earth is acheived with a unique
Auto-Connect feature removing the need for individual bonding conductors.
The panels are Nexans branded and have a series of complementary cable
management products such as blank panels and patch cord guides.
The patch panels are designed for standard 19" enclosures, are 1U high, and
support the following common features:
- 24 Ports with shutters
- Designed for Screened and Unscreened Snap-In connectors
- Compatible with all perfomance categories of connector
- Clip-On mechanism for simple earthing
- Exclusive rear cable management facilities
- Robust construction
Standards
Nexans offers three main panel versions:
International
Manufacturer specication
- Angled Panels to support high density environments
- Sliding Panels to allow quick installation and easy maintenance which feature a
exible label for port numbering
- Fixed Panels using screen printed numbering systems for labelling
- The sliding and xed panels also have LANsense Upgradeable versions
03/12/10 - http://www.nexans.co.uk
Page 98 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Snap-In Patch Panels
Product List
Nexans ref.
N521.671
N521.675
N521.661BK
N521.661
N521.663
N521.881
N521.861
N521.865
=Make to order,
=Make to stock
Name
Angled Patch Panel 24 Snap-In Black
Angled Patch Panel 24 Snap-In White
Patch Panel 24 Snap-In Fixed Black
Patch Panel 24 Snap-In Fixed White
Patch Panel 24 Snap-In Sliding White
Upgradable Patch Panel 24 Snap-In Fixed Black
Upgradable Patch Panel 24 Snap-In Sliding Black
Upgradable Patch Panel 24 Snap-In Sliding White
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 99 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Empty Patch Panels for Keystone Connectors
•
•
•
•
•
•
Compatible with Nexans keystone connectors
Designed for Essential-5 and -6 range
24 ports on 1HU
Tie wrap strain relief
Earthing and grounding features
Available in black or white
Description
Application
The modular patch panels for keystone connectors are xed panels based on 19"
frame dimensions and can house up to 24 keystone connectors on 1HU.
Design
The patch panels are designed to accomodate 24 Nexans Essential keystone
connectors. The metalwork at the back of the panel is made of unpainted steel to
enable automatic earthing and the necessary grounding when using shielded
cable and connectors. The painted front plate allows a neat ush mounting of the
connectors. The panels have screen-printed numbering 1-24 above the ports and
a labelling eld at the right end for patch panel numbering. They are available in
black (N521.660BK) and in white (N521.660).
Installation
The Nexans keystone connectors can easily be inserted by a simple "one-click"
movement, without the need for any tool. They are also easy to remove, when
necessary.
The integrated cable xing plate with tie wrap strain relief ensures cable
management and retention.
The panels are supplied with xings.
Standards
International ISO/IEC 11801
An optional 19" outrigger can be used for easy termination access (N500.120).
03/12/10 - http://www.nexans.co.uk
Page 100 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Empty Patch Panels for Keystone Connectors
Product List
Nexans ref.
N521.660BK
N521.660
N521.660BK
New
N521.660
New
Name
Empty Patch Panel for 24 keystone connectors black
Empty Patch Panel for 24 keystone connectors white
Essential Patch Panel 24 Keystone Black - New Design
Essential Patch Panel 24 Keystone White - New Design
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 101 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Modular Outlets
03/12/10 - http://www.nexans.co.uk
Page 102 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Hardware-LANmark
•
•
•
•
•
•
For all 45x45mm ttings.
Modules, Cover Plates, Surface Box
Modules include labeling and shutters.
Suitable for all snap-in connectors.
Angled modules for restricted depth.
Easy click-in mechanism.
Description
Application
This range of outlet mounting hardware is suitable for all 45mm ttings and
includes cover plates, at & angled modules for Snap-in connectors, and surface
mount boxes.
For the specic information on the Snap-in connectors, refer to the corresponding
data sheets.
There are two different faceplates to support all environments:
• The straight version
• The angled version. It offers the ideal solution for cable trays and oor boxes,
where depth is restricted. Shutters prevent dust entrance.
Guarantees
• All plastic material is UL 94V0
Standards
Installation
These modular outlets t into a wide range of international 45x45 covering plates
and surface mount boxes.
International
Manufacturer specication
For easy management and port identication, the outlets all include integrated
labelling windows.
The Snap-in connectors are inserted into the modular outlet by a simple click-in
mechanism.
Product List
Nexans
ref.
N200.051
N200.050
Name
LANmark EU style 45 x 45 frame ivory
Width
(mm)
80
LANmark EU style 45 x 45 frame white
80
LANmark EU style 45 x 45 module 2 Snap-In at
white
LANmark EU style 45 x 45 surface mount box
N200.115
ivory
LANmark EU style 45 x 45 surface mount box
N200.116
white
N423.520 LANmark EU style angled 45 x 45 module 1 SnapNew
In white
LANmark EU style angled 45 x 45 module 2 SnapN423.541N
In ivory
LANmark EU style angled 45 x 45 module 2 SnapN423.540N
In white
N423.550
45
82
82
45
=Make to order,
=Make to stock
Colour
Height
Depth
(mm)
(mm)
Ivory
80
White RAL
80
9010
White RAL
45
9010
Ivory
White RAL
9010
White RAL
9010
82
50
82
50
45
36
45
Ivory
45
36
45
White RAL
9010
45
36
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 103 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
UK Mounting Hardware for Essential
To support the Essential range of products Nexans has developed a set of UK connecting hardware in Keystone format.
For LANmark specic connecting hardware, please refer to "UK Mounting Hardware for LANmark".
Nexans backboxes and cover plates have Euromod dimensions and are common throughout the Essential and LANmark
ranges.
Description
• LJ6 Keystone Module
LJ6C shuttered module to accommodate one Keystone connector.
• 25 x 50 Keystone Module
Euromod 25x50mm shuttered module to accommodate one Keystone
connector.
Euromod modules t Nexans single and double gang cover plates.
• Single and Double Gang Cover Plates
Available in at and bevelled version.
• Single and Double Back Box
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 104 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
UK Mounting Hardware for Essential
Product List
Nexans ref.
N423.635
New
N423.630
New
N423.650
N423.640
N424.533
N424.532
N424.023
N424.531
N424.013
N424.530
N424.103
N424.003
=Make to order,
=Make to stock
Name
Essential 86x86 Wallplate 1 Keystone White
Essential 86x86 Wallplate 2 Keystone White
Essential UK style 25x50 module 1 keystone White
Essential UK style LJ6C module 1 keystone White
UK Back Box - Double Gang
UK Back Box - Single Gang
UK Cover Plate - Double Gang
UK Cover Plate - Double Gang - Bevelled
UK Cover Plate - Single Gang
UK Cover plate - Single Gang - Bevelled
UK Half Blank
UK Quarter Blank
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 105 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
UK Mounting Hardware for LANmark
To support the LANmark Snap-In range of products Nexans has developed a set of UK connecting hardware.
The mounting hardware is common to all performance levels, from LANmark-5 through LANmark-6/6A to LANmark-7/7A.
Description
LJ6 Modular Outlet
LJ6C dimensions (25mm x 37mm) Single Modular
outlets accommodate one Snap-in connector. Supplied in UK White.
shuttered
25 x 50 Modular Outlet
Single Modular shuttered outlet 25mm x 50mm suitable to accommodate one
Snap-in connector. Supplied in UK White.
Modular Outlet ts Nexans single and double gang cover plates.
Single and Double Cover Plates
Single and double gang cover plates supplied in UK White. Flat and beveled
version is available.
Single and Double back box
Standards
Single and double gang back box supplied in UK White.
International ISO/IEC 11801
Angled modular outlet
The angled modular shuttered outlet 50x50mm can accomodate 2 snap-in
connectors and is supplied in UK White. It can be used to create horizontal or
vertical quad outlets.
03/12/10 - http://www.nexans.co.uk
Page 106 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
UK Mounting Hardware for LANmark
Product List
Nexans ref.
N423.861
New
N423.862
New
N424.203
N424.113
N424.204N
New
N423.540U
N424.533
New
N424.532
New
N424.023
N424.531
New
N424.013
N424.530
New
N424.103
N424.213
N424.003
=Make to order,
=Make to stock
Name
LANmark 86x86 Wallplate 1 Snap-In White
LANmark 86x86 Wallplate 2 Snap-In White
LJ6C Angled Module
UK 25x50 Flat Module for Snap-ins
UK Angled 25x50 Module for 1 snap-in
UK Angled Module for 2 snap-ins
UK Back Box - Double Gang
UK Back Box - Single Gang
UK Cover Plate - Double Gang
UK Cover Plate - Double Gang - Bevelled
UK Cover Plate - Single Gang
UK Cover plate - Single Gang - Bevelled
UK Half Blank
UK LJ6C Flat Module for snap-ins
UK Quarter Blank
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 107 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
US Mounting Hardware for LANmark
•
•
•
•
•
•
US format
45x45 and 45x60 series of Cover Plates, for up to 6 snap-in connectors
Suitable for ber and copper
Includes xings </>
All plastic material is UL 94V0
Colour white
Description
Application
This range of mounting hardware is suitable for US ttings and includes:
• 2 types of cover plates
• N422.001: 45x45mm inner format, with integrated labelling system
• N423.001: 60x45mm inner format, with integrated labelling system
• 20x45mm module for 2 snap-in connectors (N421.610)
• 20x45mm blanking module (N420.001)
Detailed information can be found on the corresponding datasheets.
Guarantees
• All plastic material is UL 94V0
Installation
• The cover plates are all supplied with xing screws.
• All modules can be inserted in the cover plates by a simple click-in mechanism.
03/12/10 - http://www.nexans.co.uk
Standards
International UL and CSA approval
National UL 94 V0
Page 108 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
US Mounting Hardware for LANmark
Product List
Nexans
ref.
N420.001
N421.610
N422.001
N423.001
Name
Width
(mm)
45x20 Blanking module for US cover plate
45x20 Module for 2 Snap-in connectors for US
cover plate
US Cover plate for 45x45 Outlet with labelling
system
US Cover plate for 60x45 Outlet with labelling
system
45
45
70.5
70.5
=Make to order,
=Make to stock
Colour
Height
Depth
(mm)
(mm)
White RAL
20
26.5
9010
White RAL
20
16.5
9010
White RAL
115
14
9010
White RAL
115
14
9010
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 109 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
3rd Party Hardware
Description
Nexans have a range of oorplates and adaptors designed to integrate Nexans
connectivity into various 3rd party products
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 110 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
3rd Party Hardware
Product List
Nexans ref.
N800.305
N800.306
N423.110
N423.111
N423.120
N423.121
N423.122
N423.130
=Make to order,
=Make to stock
Name
Function of the accessory
Snap-In face plate for BTicino Living International range
Adaptator
Snap-In face plate for BTicino Light range
Adaptator
Plate for up to 6 Snap-In connectors for GES6 Ackermann oor box
Floor Plates
Plate for up to 9 Snap-In connectors for GES9 Ackermann oor box
Floor Plates
Plate (left part) for up to 6 Snap-In connectors for GB2 Electraplan oor box
Floor Plates
Plate (right part) for up to 6 Snap-In connectors for GB2 Electraplan oor box
Floor Plates
Plate for up to 9 Snap-In connectors for GB3 Electraplan oor box
Floor Plates
Plate for up to 9 Snap-In connectors for GE12 RK5 Obo Bettermann oor
Floor Plates
box
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 111 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
European Mounting Hardware for Essential Keystone
•
•
•
•
European mounting hardware in keystone format
Designed for Essential-5 and -6 keystone range
Supplied in glossy white nish
Also available in UK and US format.
Description
To support the Essential-5 and -6 Keystone range, Nexans has developed
specic mounting hardware in keystone format. Please refer to the specic
datasheets for keystone modules, frames and blanks.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 112 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
European Mounting Hardware for Essential Keystone
Product List
Nexans ref.
N423.645
N424.102
N200.645
Name
Essential EU style 22.5 x 45 module 1 Keystone white
Essential EU style 22.5x45 blank module white
Essential EU style 45x45 frame white
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 113 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
US Mounting Hardware for Essential
•
•
•
•
•
US mounting hardware in keystone format
Designed for Essential-5 and -6 keystone range
Supplied in textured white nish
Equipped with labelling windows
Screws included
Description
To support the Essential Keystone range Nexans has developed specic
mounting hardware in keystone format in European, UK and US style.
Please refer to the related product datasheets for the different available modules,
frames and blanks in various country specic versions.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 114 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
US Mounting Hardware for Essential
Product List
Nexans ref.
N423.622
New
N423.624
New
Name
Essential US style Wallplate 2 Keystone Single Gang White
Essential US style Wallplate 4 Keystone Single Gang White
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 115 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice grade
The Nexans Voice ange includes Voice grade cables and IDC connectivity and is
used to integrate telephony applications into a LAN infrastructure.
03/12/10 - http://www.nexans.co.uk
Page 116 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Cables
• 25pr, 50pr, or 100pr
• Suitable for voice and low grade data
• Category 3 and Category 5 compliant
Description
Voice grade cables are used to integrate telephony applications in the backbone
of a LAN infrastructure. They are multipair twisted pair cables and exist in
Category 3 and Category 5 performance levels.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 117 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Cables
Product List
Nexans ref. Name
N100.819FR
N100.809N
N100.M02
N100.M01
N100.808N
N100.M04
Number of
pairs
Voice F/UTP 100 pair AWG24 LSZH Grey 250m
reel (LYst)
Voice U/UTP 100 pair AWG24 Cat 3 PVC Grey
500m reel
Voice U/UTP 25 pair AWG24 Cat 5 LSZH Orange
1000m reel
Voice U/UTP 25 pair AWG24 Cat 5 PVC Grey
1000m reel
Voice U/UTP 50 pair AWG24 Cat 3 PVC Grey
500m reel
Voice U/UTP 50 pair AWG24 Cat 5 LSZH Orange
500m reel
=Make to order,
=Make to stock
Outer
Type of
Category
sheath
cable
100
LSZH
F/UTP
Cat. 5
100
PVC
U/UTP
Cat. 3
25
LSZH
U/UTP
Cat. 5
25
PVC
U/UTP
Cat. 5
50
PVC
U/UTP
Cat. 3
50
LSZH
U/UTP
Cat. 5
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 118 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
IDC connectivity and accessories
Complete range of LSA+ voice connectivity and accessories
Description
Nexans offers a complete range of voice IDC module and accessories in order to
build a voice backbone in any installation. Nexans uses the LSA+ type
connectivity.
The Nexans Voice range includes :
•
•
•
•
•
•
•
•
•
IDC connection modules
19" 3 HU frame
3HU patch guide
Marking cap
Open contact marking strip
Surge arrestor and protection magazine
Patch Cords
Voice MDF solution : stand alone, wall mounted or wall box
Accessories and frames
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 119 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
IDC connectivity and accessories
Product List
Nexans ref.
N102.333
N108.106
N201.001
N103.203
N102.350
N102.332
N102.310
N102.362
N102.361
N102.360
N102.321
=Make to order,
=Make to stock
Name
10xVoice IDC Label Holder for Module 10 Pairs
3HU Patch Guide for IDC Frame
IDC 1 pair marking cap red
Surge Arrestors
Voice 3HU distribution frame for 15 IDC blocks
Voice IDC Label Holder for Frame
Voice LSA+ Disconnection Module 10 pair
Voice MDF 2x26 modules wall box
Voice MDF 2x74 modules stand alone (ETSI format)
Voice MDF 81 modules wall mounted
Voice Surge Protector Magazine for 10 Pairs empty
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 120 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Patch Panels
• Hight density RJ45 panels for voice applications
• Available in black and in white
Description
Nexans high density Voice Panels are designed to integrate voice circuits in
standard structured cabling systems.
•
•
•
•
•
•
50 RJ45 ports on 1U
Mount to standard 19" rack
LSA/110 punchdown
Accept multi-pair cables from 22 to 26 AWG
Supplied with xings
Earthing strap included
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 121 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Patch Panels
Product List
Nexans ref.
N500.350BK
New
N500.350
N424.514
To be removed
Name
Voice Patch Panel 50 RJ45 2 pair Black
Voice Patch Panel 50 RJ45 2 pair White
Voice Patch Panel 50 RJ45 3 pair Black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 122 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Patch Cords
• Exists in 3 different types, depending on the application
• Unscreened exible PVC cable
Description
Application
Nexans offers 3 different types of patch cords for voice applications, for both in
the cabinet and in the work area:
• work area cord: 1 RJ45 to 1 RJ11 (N107.001)
• cabinet patch cords:
• 1 RJ45 to 1 IDC - 1 pair (N108.165 and N108.166)
• 1 RJ45 to 1 IDC - 2 pairs (N108.209 and N108.210)
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 123 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Voice Patch Cords
Product List
Nexans ref.
N107.001
N108.165
N108.166
N108.209
N108.210
=Make to order,
Name
Voice 2 pairs Patch Cord RJ45-RJ11 Black 5m
Voice 1 pair Patch Cord 100 Ohm IDC - RJ45 Grey 1,5m
Voice 1 pair Patch Cord 100 Ohm IDC - RJ45 Grey 3m
Voice 2 pairs Patch Cord 100 Ohm IDC - RJ45 Grey 1,5m
Voice 2 pairs Patch Cord 100 Ohm IDC - RJ45 Grey 3m
= Make to order,
03/12/10 - http://www.nexans.co.uk
=Make to stock
Length (m)
5
1.5
3
1.5
3
= Make to stock
Page 124 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Tools & Accessories
03/12/10 - http://www.nexans.co.uk
Page 125 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Tools
Description
Nexans have a complete range of tools for terminating copper systems
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 126 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Tools
Product List
Nexans ref.
N102.107
N422.117
N422.118
N420.567
N808.6000
N808.6020
N808.6010
N420.110
N500.120
=Make to order,
=Make to stock
Name
Tool - LSA+ IDC punchdown tool
Tool - LANmark-7 Easy Termination tool
Tool - Set of spare knives for LANmark-7 Easy Termination tool
Tool - Universal Comfort tool for Snap-in connector
Universal Termination Tool for 808 connector
360° Connector Crimp Tool for 808 connector
360° Sheath splitting tool for 808 connector
Tool - Nexans cable stripper, 110 punchdown tool
19" support tray for termination
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 127 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Keystone Clips
• Adaptor clips for LANmark Snap-In connectors
Description
Various clips to turn LANmark Snap-In connectors into Keystone format.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 128 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Keystone Clips
Product List
Nexans ref.
N429.620
N429.625
N429.626
N429.627
New
Name
Metal clip for Snap-In to keystone
Red clip for EVO Snap-In connector to keystone format (wall thickness 1,5-1,75 mm)
Blue clip for EVO Snap-In connector to keystone format (wall thickness 2,0-2,25 mm)
Yellow clip for EVO Snap-In connector to keystone format (height 19,7 mm)
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 129 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Retrofit Hoods
Description
A range of coloured patchcord hoods/boots that can be tted to
LANconnect-5e FTP range of cords
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 130 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Retrofit Hoods
Product List
Nexans ref.
N111.H2S
N111.H2B
N111.H2V
N111.H2F
N111.H2O
N111.H2R
N111.H2J
=Make to order,
=Make to stock
Name
Hood - LANconnect 5e FTP Black (Pack of 50)
Hood - LANconnect 5e FTP Blue (Pack of 50)
Hood - LANconnect 5e FTP Green (Pack of 50)
Hood - LANconnect 5e FTP Grey (Pack of 50)
Hood - LANconnect 5e FTP Orange (Pack of 50)
Hood - LANconnect 5e FTP Red (Pack of 50)
Hood - LANconnect 5e FTP Yellow (Pack of 50)
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 131 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Pre-terminated Copper
03/12/10 - http://www.nexans.co.uk
Page 132 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Pre-Term Bundles
•
•
•
•
•
•
•
•
Ideal assemblies for high density cabling and datacenters
Bundles available for Jack-Jack or Jack-Plug or Plug-Plug units
Bundles available for 6,12 or 24 units
Cat.6, 6A, 7 or 7A perfomance supported
Fully screened and compliant to Alien Crosstalk requirements
Repeatable and stable level of performance
Signicant reduction of cable laying time
Bundles are suitable for laying but not pulling operation
Description
Application
LANmark Pre-Term Bundles are assemblies of 6,12 or 24 pre-terminated units.
These can be Jack-Jack, Jack-Plug or Plug-Plug units. These units are
maintained together as a bundle though spriral wrapping every meter. LANmark
Pre-Term Bundles are well suited for areas where installation time is limited.
Bundles of shielded units ensure immunity from Alien Crosstalk and other external
interference. Bundles of shielded units do not requied on-site testing for Alien
Crosstalk since this new parameter is met by design.
Performance
Cat.6/Class E, Cat.6A/Class EA, Cat.7/Class F or Cat.7A/Class FA units can be
bundled. Headroom and bandwidth over and above the given category
requirements according to the international, european and american standards
especially for NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss are
guaranteed. When used in combination with LANmark patch cords of the same
category the full 100m four-connector links and channels are guaranteed as well.
Standards
International ISO/IEC 11801:2002/
A2:2008
National TIA/EIA-568-B.2-10
Installation
Nexans LANmark Pre-Term Bundles help reducing the installation time. One
assembly needs to be layed instead of 6, 12 or 24 single cables. Furtermore
connectors termination is simply eliminated. Connectors are mounted and tested
in our factory.
Nexans LANmark Pre-Term Bundles are designed to be layed and are not
suitable for pulling.
All structural hardware items designed for the Snap-In range can be used in all
positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO).
•
•
•
•
•
•
•
Fast and straigt forward installation
No need for on-site termination
Reduction of installation time
360° EMC protection and alien crosstalk compliance for shielded products
Support the 4 connectors channel conguration
Numbering on each leg (customizable)
Factory tests in paper or electronic format on request
Guarantees
Nexans LANmark Pre-Term bundles are covered by a parts and labour warranty
as described in the Nexans Certied System Warranty. When installed in
combination with LANmark patch cords of the same category, a 25 year channel
warranty can be obtained.
03/12/10 - http://www.nexans.co.uk
Page 133 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Pre-Term Bundles
Product List
Nexans ref.
N62A.2C21A4XA4X--New
N62A.2A21B4XB4X--New
N63A.4G21A6XA6X--New
N63A.4C21A6XA6X--New
N63A.4C21A6XXXX--New
N63A.4F11A6XC6X--New
N63A.4F11CA6XXXX--New
N65A.4F11A6XC6X--New
N68A.4C21A6XA6X--New
N68A.4C21A6XXXX--New
N64A.4C21A6XA6X--New
N64A.4C21A6XXXX--New
N64A.4F11A6XC6X--New
N64A.4G21A6XA6X--New
N62A.4G21A6XA6X--New
N62A.4C21A6XA6X--New
N62A.4C21A6XXXX--New
N62A.4F11A6XC6X--New
N62A.4F11C6XXXX--New
N67A.4C21A6XA6X--New
N64A.6H21A8XA8X--New
=Make to order,
=Make to stock
Name
LANmark-6 Pre-Term Bundle of 6 Cat 6 F1/UTP Solid LSZH Orange Screened Jack Cat 6
LANmark-6 Pre-Term Bundle of 6 Cat 6 U/UTP Solid LSZH Orange Unscreened Jack Cat 6
LANmark-6A Pre-Term Bundle of 12 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A
LANmark-6A Pre-Term Bundle of 12 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Bundle of 12 Cat 6A F1/UTP Solid LSZH Orange Screened Single end
Jack Cat 6A
LANmark-6A Pre-Term Bundle of 12 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug
LANmark-6A Pre-Term Bundle of 12 Cat 6A U/FTP Stranded LSZH Orange Screened Plug
LANmark-6A Pre-Term Bundle of 16 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug
LANmark-6A Pre-Term Bundle of 18 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Bundle of 18 Cat 6A F1/UTP Solid LSZH Orange Screened Single end
Jack Cat 6A
LANmark-6A Pre-Term Bundle of 24 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Bundle of 24 Cat 6A F1/UTP Solid LSZH Orange Screened Single end
Jack Cat 6A
LANmark-6A Pre-Term Bundle of 24 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug
LANmark-6A Pre-Term Bundle of 2x12 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Bundle of 6 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A
LANmark-6A Pre-Term Bundle of 6 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A
LANmark-6A Pre-Term Bundle of 6 Cat 6A F1/UTP Solid LSZH Orange Screened Single end
Jack Cat 6A
LANmark-6A Pre-Term Bundle of 6 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug
LANmark-6A Pre-Term Bundle of 6 Cat 6A U/FTP Stranded LSZH Orange Screened Plug
LANmark-6A Pre-Term Bundle of 8 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A
LANmark-7A Pre-Term Bundle of 24 Cat 7A S/FTP Solid LSZH Orange Screened Jack Cat 7A
= Make to order,
= Make to stock
Selling delivery information
Nexans LANmark Pre-Term Bundles can be ordered in any length up to 90m. Please refer to Nexans Design Guidelines for
length calculations and limitations according to the standards. Individual packaging in boxes (L <30m) or one way reel
(L>30m). Customized packaging on demand.
03/12/10 - http://www.nexans.co.uk
Page 134 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Pre-Term Units
•
•
•
•
Pre-Term units available in Jack-Jack or Jack-Plug or Plug-Plug assemblies
Cat.6, 6A, 7 or 7A perfomance supported
Repeatable and stable level of performance
Signicant reduction of cable laying time
Description
Standards
International ISO/IEC 11801
Application
LANmark Pre-Term pre-terminated units can be Jack-Jack, Jack-Plug or PlugPlug assemblies. LANmark Pre-Term units are well suited for areas where
installation time is limited. Shielded units ensure immunity from electromagnetic
interferences and do not requied on-site testing for Alien Crosstalk since this new
parameter is met by design.
Performance
Cat.6/Class E, Cat.6A/Class EA, Cat.7/Class F or Cat.7A/Class FA units can be
made. Headroom and bandwidth over and above the given category requirements
according to the international, european and american standards especially for
NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss are guaranteed. When
used in combination with LANmark patch cords of the same category the full
100m four-connector links and channels are guaranteed as well.
Installation
Nexans LANmark Pre-Term Units help reducing the installation time since
connectors termination is simply eliminated. Connectors are mounted and tested
in our factory.
Nexans LANmark Pre-Term Units are designed to be layed and are not suitable
for pulling.
All structural hardware items designed for the Snap-In range can be used in all
positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO).
•
•
•
•
•
•
•
Fast and straigt forward installation
No need for on-site termination
Reduction of installation time
360° EMC protection and alien crosstalk compliance for shielded products
Support the 4 connectors channel conguration
Numbering on each Unit (customizable)
Factory tests in paper or electronic format on request
Guarantees
Nexans LANmark Pre-Term Units are covered by a parts and labour warranty as
described in the Nexans Certied System Warranty. When installed in
combination with LANmark patch cords of the same category, a 25 year channel
warranty can be obtained.
03/12/10 - http://www.nexans.co.uk
Page 135 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Pre-Term Units
Product List
Nexans ref.
N61A.2C21A4XA4X--New
N61B.4G21A6XA6X--New
N61A.4F11A6XC6X--New
Name
LANmark-6 Pre-Term Cat 6 F1/UTP Solid LSZH Orange Screened Jack Cat 6 unit
LANmark-6A Pre-Term 2x4 Pair Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A unit
LANmark-6A Pre-Term Cat 6A U/FTP Stranded LSZH Orange Screened Jack-Plug Cat 6A unit
= Make to order,
= Make to stock
Selling delivery information
Nexans LANmark Pre-Term Units can be ordered in any length up to 90m. Please refer to Nexans Design Guidelines for
length calculations and limitations according to the standards. Individual packaging in boxes (L <30m) or one way reel
(L>30m). Customized packaging on demand.
03/12/10 - http://www.nexans.co.uk
Page 136 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack
•
•
•
•
•
•
•
Ideal assemblies for 10GBase-T applications and datacenters
Fully compliant to the new Category 6A and Class EA standards
Guaranteed performance in 2, 3 or 4 connectors channels up to 500MHz
Very short distances for datacenters supported
Fully screened and compliant to Alien Crosstalk requirements
Enable fast installation and eliminate eld termination
Reapetable and stable level of performance
Description
Application
LANmark-6A Pre-Term Category 6A U/FTP solid LSZH orange screened Jack
Category 6A assemblies have been designed specically to support the higher
frequencies required for 10 Gigabit Ethernet, while maintain to be fully backwards
compatible with today's needs. All LANmark-6A products making the assemblies
are screened to ensure immunity from Alien Crosstalk and other external
interference and are specied up to frequencies of 500MHz. LANmark-6A EVO
jacks use a fully closed rear cover providing 360° screening and excellent
coupling attenuation.The Mulipair cable is made of individually screened pairs
assembled in several 4 pair units.These LANmark-6A Pre-Term Category 6A
assemblies do not requied on-site testing for Alien Crosstalk since this new 10G
parameter is met by design.
•
•
•
•
•
•
•
10Base-T Ethernet
100Base-TX Fast Ethernet
1000Base-TX Gigabit Ethernet
10GBase-T 10 Gigabit Ethernet IEEE 802.3an
155 Mbit ATM
1.2 Gbit ATM
future Cat 6A and Class EA applications
Standards
International EN 50173-5;
IEEE 802.3an; ISO/IEC 11801:2002/
A2:2008; ISO/IEC 24764
National TIA/EIA-568-B.2-10; TIA/
EIA-942
Performance
With guaranteed performance to 500MHz, Nexans LANmark-6A Pre-Term
Category 6A assemblies provide guaranteed headroom and bandwidth over and
above the Category 6A / Class EA requirements of international, european and
american standards especially for NEXT/FEXT, Power Sum NEXT/FEXT
and Return Loss. When used in combination with LANmark-6A patch cords, the
system supports the 10GBase-T applications as dened in IEEE 802.3an, and the
full 100m four-connector links and channels meet Category 6A and Class EA
requirements as dened in TIA/EIA568B.2 Addendum 10 and ISO/IEC11801
2002/A1:2008. This enables to achieve high performing 4 connectors channels as
well as very short link and channel congurations needed in data centres with up
to 3 connection points within 12 meters.
Installation
Nexans LANmark-6A Pre-Term Category 6A assemblies have the advantage of
offering signicantly smaller dimensions and reduced weight compared to the
equivalent standard 4 pair cables. They also provide a signicant installation
advantage. Cable pulling is reduced to one unit. Connectors termination is simply
eliminated.
All structural hardware items designed for the EVO Snap-In range can be used in
all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO).
03/12/10 - http://www.nexans.co.uk
Page 137 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack
•
•
•
•
•
•
•
•
Fast and straight forward installation
No need for on-site termination
360° EMC protection and alien crosstalk compliance
Support the 4 connectors channel conguration
Support short links
Designed for datacentres
Numbering on each leg (customizable)
Factory tests in paper or electronic format on request
Guarantees
Nexans LANmark-6A Pre-Term Category 6A assemblies are covered by a parts
and labour warranty as described in the Nexans Certied System Warranty. When
installed in combination with LANmark-6A patch cords, a 25 year channel
warranty can be obtained covering full 10GBase-T support and full Cat 6A/Class
EA compliance.
03/12/10 - http://www.nexans.co.uk
Page 138 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack
Product List
Nexans ref.
N61C.4F21A6XA6X--New
N61D.4F21A6XA6X--New
N61E.4F21A6XA6X--New
Name
LANmark-6A Pre-Term Multipair 3x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Multipair 4x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat
6A
LANmark-6A Pre-Term Multipair 6x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat
6A
= Make to order,
= Make to stock
Electrical Performance LANmark-6A 4 Connector Channel Part 1
"All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance"
Freq
Attn
NEXT
PSNEXT
ACR-F
in dB
in dB
in dB
in dB
in MHz
Max
Typ
Std
Min
Typ
Std
Min
Typ
Std
Typ
1
<4
4.0
65.0
67.0
85.0
62.0
64.0
74.8
63.3
69.9
4
4.1
4.1
63.0
65.0
72.9
60.5
62.5
65.0
51.2
57.9
10
6.4
6.3
56.6
58.6
65.0
54.0
56.0
58.5
43.3
49.9
16
8.1
8.0
53.2
55.2
60.9
50.6
52.6
55.1
39.2
45.9
20
9.1
9.0
51.6
53.6
59.0
49.0
51.0
53.5
37.2
43.9
31.25
11.4
11.2
48.4
50.4
55.1
45.7
47.7
50.2
33.4
40.0
62.5
16.3
15.9
43.4
45.4
49.1
40.6
42.6
45.1
27.3
34.0
100
20.8
20.2
39.9
41.9
45.0
37.1
39.1
41.6
23.3
29.9
155
26.2
25.4
36.7
38.7
41.2
33.8
35.8
38.3
19.5
26.1
200
30.0
28.9
34.8
36.8
39.0
31.9
33.9
36.4
17.2
23.9
250
33.8
32.5
33.1
35.1
37.0
30.2
32.2
34.7
15.3
22.0
300
37.3
35.7
31.7
33.7
35.4
28.8
30.8
33.3
13.7
20.4
500
49.3
46.7
27.9
29.9
31.0
24.8
26.8
24.9
9.3
16.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
03/12/10 - http://www.nexans.co.uk
Page 139 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack
Electrical Performance LANmark-6A 4 Connector Channel Part 2
All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and
maximum values represent guaranteed channel performance
PS ACR-F
Freq
PS ANEXT
in dB
PS AACR-F
in dB
RL
in dB
in dB
in MHz
Std
Typ
Std
Min
Typ
Std
Min
Typ
Std
Min
Typ
1
60.3
66.9
80.0
90.0
92.0
77.0
92.0
94.0
19.0
21.0
21.0
4
48.2
54.9
74.0
89.0
91.0
65.0
80.0
82.0
19.0
21.0
32.0
10
40.3
46.9
70.0
85.0
87.0
57.0
72.0
74.0
19.0
21.0
28.0
16
36.2
42.9
68.0
83.0
85.0
52.9
67.9
69.9
18.0
20.0
26.0
20
34.2
40.9
67.0
82.0
84.0
51.0
66.0
68.0
17.5
19.5
25.0
31.25
30.4
37.0
65.1
80.1
82.1
47.1
62.1
64.1
16.5
18.5
23.1
62.5
24.3
31.0
62.0
77.0
79.0
41.1
56.1
58.1
14.0
16.0
20.0
100
20.3
26.9
60.0
75.0
77.0
37.0
52.0
54.0
12.0
14.0
18.0
155
16.5
23.1
57.1
72.1
74.1
33.2
48.2
50.2
10.1
12.1
16.1
200
14.2
20.9
55.5
70.5
72.5
31.0
46.0
48.0
9.0
11.0
15.0
250
12.3
19.0
54.0
69.0
71.0
29.0
44.0
46.0
8.0
10.0
14.0
300
10.7
17.4
52.8
67.8
69.8
27.5
42.5
44.5
8.0
10.0
13.2
500
6.3
13.0
49.5
64.5
66.5
23.0
38.0
40.0
8.0
10.0
11.0
*Standard values based on ISO11801:2002/A1:2008 ClassEA
Selling delivery information
Nexans LANmark-6A Pre-Term Category 6A assemblies can be ordered in any length up to 90m. Please refer to Nexans
Design Guidelines for length calculations and limitations according to the standards. Individual packaking in boxes (L <30m)
or one way reel (L>30m). Customized packaking on demand.
03/12/10 - http://www.nexans.co.uk
Page 140 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Optical Fibre
A full spectrum of Nexans LANmark ber solutions is available for various
performance levels and constructions to meet different applications and
environmental conditions. LANmark bre solutions approach offers exibility and
scalability for campus and building backbones, horizontal cabling applications,
device termination in data centers and storage area networks.
Nexans bre solutions are a fully integrated element of our LAN systems and
covered within the system warranty.
The range includes:
•
•
•
•
Cables
Connectivity
Hardware
Pre-Terminated Fibre Assemblies
03/12/10 - http://www.nexans.co.uk
Page 141 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre Cables
A wide variety of cable designs and bre grade are available, meeting the needs
of each mission critical applications. Designed for high performance and
scalability for LAN, SAN and Campus applications, LANmark-OF technology
deliver premium performance and reliability.
A large number of constructions are available: Tight / loose construction, PE /
LSZH., rodent resistant / dielectric, …
•
•
•
•
•
•
UT
UC
UD
TB
TBW+
ZC
In addition, Nexans proposes the best cost effective solution. 7 different bre
grades are available to best address the level of performance required.p>
LANmark-OF 1, OF 2 & OF sm
Standard Multimode & Singlemode performance. LANmark-OF 1 is the MM62.5
version, LANmark-OF 2 the MM50 version, LANmark-OF sm the singlemode
version.
LANmark-OF 1xt & OF 2xt
Laser optimised, enhanced OM1 & OM2 respectively (50/125 & 62.5/125) bre
cables designed to provide extended distances for Gigabit applications.
LANmark-OF 3 & OF 3xt
OM3 compliant 50/125 for 10 Gigabit applications up to 300m and up to 450m
respectively..
EIA Fibre Colour Table
EIA Fibre Colour Coding
Fibre
Colour
Fibre
Colour
1
Blue
13
Blue + 1 ring
I
2
Orange
14
Orange + 1 ring
I
3
Green
15
Green + 1 ring
I
4
Brown
16
Brown + 1 ring
I
5
Grey
17
Grey + 1 ring
I
6
White
18
White + 1 ring
I
7
Red
19
Blue + 2 rings
II
8
Black
20
Orange + 2 rings
II
9
Yellow
21
Green + 2 rings
II
10
Violet
22
Brown + 2 rings
II
11
Pink
23
Grey + 2 rings
II
12
Turquoise
24
White + 2 rings
II
03/12/10 - http://www.nexans.co.uk
Page 142 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Optical cable specifications
• Full range of standard compliant multimode cables
• Singlemode OS2 cables
Description
LANmark-OF OM3 and OM4: Fibre cables with high
performance multimode fibres for 10, 40 and 100 Gb/s
Ethernet LAN applications
LANmark-OF OM3 and OM4 from Nexans Cabling Solutions offers fully OM3 and
OM4 standard compliant multimode bres. LANmark-OF OM3 and OM4 ensures
highest bandwidth performance for Premises, Local Area Network (LAN) and
Storage Area Network (SAN) while its optimised design for low-cost 850 nm
lasers (VCSEL) contributes to overall system cost reduction.
The low attenuation values of 3.0 dB/km @ 850 nm exceed the requirements of
the ISO/IEC 11801 standard. The superior geometric tolerances compared to the
bre standard reduce the connector loss due to improved coupling from the light.
The effective modal bandwidth is measured with the most stringent DMD
characterisation methods: LANmark-OF cables are measured against both the
Effective Model Bandwidth Calculated (EMBc) method and the mask templates
standard.
LANmark-OF OM3: Key performance characteristics
• Guarantees reliable system performance for 10 Gb/s Ethernet serial
transmission over 330 m.
• Guarantees reliable system performance for 40 Gb/s and 100 Gb/s Ethernet
transmission over 100 m.
• Guaranteed OM3 compliance: Effective Modal Bandwidth (EMB) of 2000
Mhz.km, Overlled Launch Bandwidth (OFL) of 1500 Mhz.km @ 850 nm and
500 Mhz.km @ 1300 nm.
• Compliant to IEC 60793-2-10 as bre type A1a.2
Standards
International ISO/IEC 11801
LANmark-OF OM4: Key performance characteristics
• Guarantees reliable system performance for 10 Gb/s Ethernet serial
transmission over 550 m
• Guarantees reliable system performance for 40 Gb/s and 100 Gb/s Ethernet
transmission over 150 m with LANmark-OF low loss connectivity.
• Guaranteed OM4 compliance: Effective Modal Bandwidth (EMB) of 4700
Mhz.km, Overlled Launch Bandwidth (OFL) of 3500 Mhz.km @ 850 nm and
500 Mhz.km @ 1300 nm.
• Compliant to IEC 60793-2-10 as bre type A1a.3
Standardization and compliances for LANmark-OF OM3 and
LANmark-OF OM4
• IEC 60793-1-49: differential mode delay (DMD) to measure effective modal
bandwidth (EMB)
• IEC 60793-1-41: overlled mode launch bandwidth (OFL BW)
• ISO/IEC 11801 (2) as OM3 and OM4 bre
• IEC 60793-2-10 as bre type A1a.2 for LANmark-OF OM3
• IEC 60793-2-10 as bre type A1a.3 for LAnmark-OF OM4
LANmark-OF OS2 Singlemode cables with low water peak
singlemode fibre (G.652.D)
03/12/10 - http://www.nexans.co.uk
Page 143 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Optical cable specifications
Singlemode OS2 cables from Nexans Cabling Solution are cables with full
spectrum bres and provide enhanced performance across the entire 1260 nm to
1625 nm wavelength range. Due to its long-term low attenuation at the 1383 nm
water peak region the bres allow operation in the expanded band (wavelength
across 1360 to 1480 nm).
Its full-spectrum capability allows use of lasers for DWDM and CWDM
technologies. LANmark-OF OS2 Singlemode cables have low attenuation values
across the entire wavelength range. They are full compatibility and interoperability
with the installed bre base, including standard singlemode bre according to
ITU-T G652A, B and C.
Standardization
Singlemode OS2
•
•
•
•
and
compliances
for
LANmark-OF
ITU-T as bre type G.652.D
Singlemode OS2 cable dened in ISO/IEC 11801 amendment 2
IEC 60793-1
IEC 60793-2-50 as bre type B1.3
LANmark-OF OM3 and OM4: Optical Performance
Characteristics
OM3 Spec Values OM4 Spec Values
Unit
Bandwidth (Overlled Launch) 850 nm
≥ 1500
≥ 3500
Mhz.km
Bandwidth (Overlled Launch) 1300 nm
≥ 500
≥ 500
Mhz.km
Effective Modal Bandwidth (EMB) 850 nm
≥ 2000
≥ 4700
Mhz.km
Transmission link lengths for 1 Gb/s (SX/LX)
880/550
900/550
m
Transmission link lengths for 10 Gb/s (SR/LX4)
330/300
550*/300
m
Transmission link lengths for 40 Gb/s (SR4)
100
150*
m
Transmission link lengths for 100 Gb/s (SR10)
100
150*
m
Attenuation 850 nm
3.0
3.0
dB/km
Attenuation 1300 nm
1.0
1.0
dB/km
Attenuation uniformity
≤ 0.2
≤ 0.2
dB
0.20 ± 0.02
0.20 ± 0.02
Numerical Aperture
* with engineered link of maximum 1.0 dB connector insertion loss
LANmark-OF OM3 and OM4: Geometrical Characteristics
Characteristic
Core Diameter
Core Non-Circularity
Core/Clad Concentricity
Cladding Diameter
Cladding Non-Circularity
Coating Diameter
Coating/Clad Concentricity Error
Spec Values Unit
50 ± 2.5
µm
≤ 6.0
%
≤ 1.5
µm
125 ± 1.0
µm
≤ 1.0
%
250 ± 15.0
µm
≤ 10.0
µm
03/12/10 - http://www.nexans.co.uk
Page 144 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Optical cable specifications
LANmark-OF OS2 Singlemode cables: Optical Performance
Characteristics
Spec Values
Fibre type
Unit
G.652.D
Transmission link length for 1000Base-LX
5000
m
Transmission link length for 10GBase-LR
10000
m
Transmission link length for 10GBase-LX4
10000
m
Transmission link length for 10Gbit-FC
10000
m
Attenuation 1300 nm
0.40
dB/km
Attenuation 1385 nm
0.40
dB/km
Attenuation 1550 nm
0.28
dB/km
Attenuation uniformity
≤ 0.2
dB
Cut-off wavelength
1150 - 1330
nm
≤ 3.5
ps/nm.km
Dispersion 1285-1330 nm
Dispersion 1550 nm
Zero dispersion
Dispersion mode polarisation
≤ 18
ps/nm.km
1310 ± 10
nm
≤ 0.2
ps/√km
LANmark-OF Singlemode OS2 cables: Geometrical Characteristics
Characteristic
Spec Values Unit
Mode Field Diameter
9.2 ± 0.5
µm
Cladding Diameter
125 ± 1.0
µm
Coating Diameter
245 ± 10.0
µm
Core Non-Circularity
≤ 6.0
%
Cladding Non-Circularity
≤ 2.0
%
Proof test
100
psi
03/12/10 - http://www.nexans.co.uk
Page 145 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Tight Buffer Indoor
• Tight Buffer Indoor optical bre cable
• Indoor cable
• Aramid yarns for ease of installation
• Designed for direct termination and splicing
• Up to 24 bres and available in all bre grades
Description
Description and Application
The LANmark-OF Tight buffer Indoor has 900 um buffered bres. This second
coating till 900 um provides additional protection of the bres and facilitates the
handling when terminating the bres in a patch panel. The easy strip tight buffer
design allows stripping the bre over 10 cm in one action.
The LANmark-OF Tight buffer Indoor is most suitable for direct termination by
either anaerobic or hot melt connectors. The tight buffered bres can also be
terminated with splicing of pigtails.
The dry structure of the LANmark-Of Tight Buffer Indoor allows both vertical and
horizontal installations. It complies with the indoor re requirements. The cables
can also be installed in a duct by pulling.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
Standards
Outer sheath in LSZH material
Aramid Yarns
Optical bre (900 um)
Central Strength element (not for 2 bres)
International ISO/IEC 11801
Characteristics
•
•
•
•
•
•
•
•
Designed for direct termination and splicing
Indoor cable for horizontal and vertical installations
Dielectric design
Flame retardant (IEC 60332-1)
Fire retardant (IEC 60332-3)
Aramid yarns for ease of handling and as strength element
Available in all bre grades
Available till 24 bres
Mechanical resistance to
impacts
100 impacts of 1 N.m
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Ambient installation
temperature, range
0 .. 40 °C
03/12/10 - http://www.nexans.co.uk
Operating temperature,
range
-20 .. 60 °C
Storage temperature,
range
-40 .. 60 °C
Page 146 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Tight Buffer Indoor
Characteristics
Mechanical characteristics
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Flame retardant
Fire retardant
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
100 impacts of 1 N.m
100 N/cm
IEC 60332-1
IEC 60332-3
0 .. 40 °C
-20 .. 60 °C
-40 .. 60 °C
Mechanical and Dimensional Characteristics for Tight Buffer Indoor
Nb optical
fibres
2
4
6
8
12
24
Nom.
outer
diam.
[mm]
4.7
4.6
4.6
5.3
6.6
7.3
Approx.
weight
[kg/km]
17
24
24
33
48
60
static
bending
rad.
[mm]
35
45
45
70
70
75
Min. dynamic
operating bending
rad.
[mm]
100.0
100.0
100.0
110.0
135.0
150.0
Maximum pulling
Maximum operating
force (IEC 60794-1-2pulling force
E1)
[N]
[N]
800
400
700
200
700
200
1200
300
1200
300
1900
550
N-numbers for Tight Buffer Indoor
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
Nexans ref.
N160.TBIN02
N160.TBIN04
N160.TBIN06
N160.TBIN08
N160.TBIN12
N160.TBIN24
N162.TBIN02
N162.TBIN04
N162.TBIN06
N162.TBIN08
N162.TBIN12
N162.TBIN24
N165.TBIN02
N165.TBIN04
N165.TBIN06
N165.TBIN08
N165.TBIN12
N165.TBIN24
N167.TBIN02
N167.TBIN04
N167.TBIN06
N167.TBIN08
N167.TBIN12
N167.TBIN24
Name
LANmark-OF Tight Buffer Indoor 2x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 4x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 6x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 8x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 12x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 24x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM4 LSZH Orange
03/12/10 - http://www.nexans.co.uk
Page 147 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Tight Buffer Indoor
Fiber optic type
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Nexans ref.
N164.TBIN02
N164.TBIN04
N164.TBIN06
N164.TBIN08
N164.TBIN12
N164.TBIN24
Name
LANmark-OF Tight Buffer Indoor 2x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Tight Buffer Indoor 4x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Tight Buffer Indoor 6x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Tight Buffer Indoor 8x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Tight Buffer Indoor 12x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Tight Buffer Indoor 24x Singlemode 9/125 OS2 LSZH Yellow
03/12/10 - http://www.nexans.co.uk
Page 148 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Tight Buffer Universal
• Tight Buffer Universal optical bre cable
• Indoor cable and outdoor installation in a duct
• Fully waterproof and rodent retardant
• Designed for direct termination and splicing
• Up to 24 bres and available in all bre grades
Description
Description and Application
The LANmark-OF Tight buffer Universal has 900 um buffered bres. This second
coating till 900 um provides additional protection of the bres and facilitates the
handling when terminating the bres in a patch panel. The easy strip tight buffer
design allows stripping the bre over 10 cm in one action.
The LANmark-OF Tight buffer Universal is most suitable for direct termination by
either anaerobic or hot melt connectors. The tight buffered bres can also be
terminated with splicing of pigtails.
The dry structure of the LANmark-Of Tight Buffer Universal allows both vertical
and horizontal installations. It complies with the indoor re requirements. The
cables can also be installed in a duct by pulling.
The LANmark-OF Tight Buffer Universal can be used for outdoor installation in a
duct: the water tight glass yarns make the cables fully waterproof and rodent
resistant.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
LSZH outer sheath with UV resistant additive
Watertight glass yarns
Optical bres (900 um)
Central strength element
Standards
International ISO/IEC 11801
Characteristics
•
•
•
•
•
•
•
•
•
•
Designed for direct termination and splicing
Dielectric design
Indoor cable for horizontal and vertical installations
Flame retardant (IEC 60332-1) and re retardant (IEC 60332-3)
Outdoor cable for installation in a duct
Fully waterproof
Rodent resistant
UV resistant
Available in all standard compliant bre grades
Available till 24 bres
Mechanical resistance to
impacts
100 impacts of 1 N.m
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Ambient installation
temperature, range
0 .. 40 °C
03/12/10 - http://www.nexans.co.uk
Operating temperature,
range
-40 .. 70 °C
Storage temperature,
range
-40 .. 70 °C
Page 149 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Tight Buffer Universal
Characteristics
Mechanical characteristics
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Flame retardant
Fire retardant
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
100 impacts of 1 N.m
100 N/cm
IEC 60332-1
IEC 60332-3
0 .. 40 °C
-40 .. 70 °C
-40 .. 70 °C
Mechanical and Dimensional Characteristics for Tight Buffer Universal
Number of optical fibres
Nominal outer diameter
Approximate weight
Minimum static operating bending radius
Minimum dynamic operating bending radius
Maximum pulling force (IEC 60794-1-2-E1)
Maximum operating pulling force
4
5.7
38
90
120.0
1000
300
6
5.7
38
90
120.0
1000
300
8
6.5
47
100
130.0
1300
400
12
7.5
68
120
150.0
1700
500
24
10.6
135
160
210.0
2300
550
mm
kg/km
mm
mm
N
N
N-numbers for Tight Buffer Universal
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Nexans ref.
N160.TBUN04
N160.TBUN06
N160.TBUN08
N160.TBUN12
N160.TBUN24
N162.TBUN04
N162.TBUN06
N162.TBUN08
N162.TBUN12
N162.TBUN24
N165.TBUN04
N165.TBUN06
N165.TBUN08
N165.TBUN12
N165.TBUN24
N167.TBUN04
N167.TBUN06
N167.TBUN08
N167.TBUN12
N167.TBUN24
N164.TBUN04
N164.TBUN06
N164.TBUN08
N164.TBUN12
N164.TBUN24
Name
LANmark-OF Tight Buffer Universal 4x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Tight Buffer Universal 6x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Tight Buffer Universal 8x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Tight Buffer Universal 12x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Tight Buffer Universal 24x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM2 LSZH Black
LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM2 LSZH Black
LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM2 LSZH Black
LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM2 LSZH Black
LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM2 LSZH Black
LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM3 LSZH Black
LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM3 LSZH Black
LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM3 LSZH Black
LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM3 LSZH Black
LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM3 LSZH Black
LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM4 LSZH Black
LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM4 LSZH Black
LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM4 LSZH Black
LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM4 LSZH Black
LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM4 LSZH Black
LANmark-OF Tight Buffer Universal 4x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Tight Buffer Universal 6x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Tight Buffer Universal 8x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Tight Buffer Universal 12x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Tight Buffer Universal 24x Singlemode 9/125 OS2 LSZH Black
03/12/10 - http://www.nexans.co.uk
Page 150 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Indoor
• Micro-Bundle Indoor optical bre cable
• Indoor cable for backbones and data centres
• Small, but mechancial strong cable
• Designed for splicing with pigtails
• 12-96 bres and available in all bre grades
Description
Description and Application
The new Micro-Bundle technology from Nexans allows to manufacture a exible
and small tube. This Micro-Bundle is the central part of the new “LANmark-OF
Micro-Bundle Indoor” cable design. The Micro-Bundle contains 12 bres with a
bre diameter of 250 um. Termination of these bres is done with splicing with
pigtails.
Up to 8 Micro-bundles are arranged around a central strength element. Aramid
yarns provide additional strength and make the cable installer friendly. The
combination of the Micro-Bundle technology, the central strength element and
aramid yarns result in a mechanical robust, but also small and exible cable. This
makes it a optimised cable for data centres and backbones
The small bending radius of the LANmark-OF Micro-Bundle Indoor makes the
cable easy to arrange in patch panels, in cable trays and in ducts.
The LANmark-OF Micro-Bundle Indoor complies with the indoor re requirements.
Since there is no drip effect of the very limited amount of gel the cable is
optimised for both horizontal and vertical installations.
Standards
International ISO/IEC 11801
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
5.
Central strength element
Micro-Bundle with 12 bres
Optical bre (250 µm)
Reinforced aramid yarns
Outer sheath in LSZH material
Mechanical resistance to
impacts
10 impacts of 1 N.m
Ambient installation
temperature, range
0 .. 40 °C
Operating temperature,
range
-10 .. 60 °C
Storage temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Page 151 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Indoor
Characteristics
•
•
•
•
•
•
•
•
•
•
•
Micro-Bundle design for easy installation
Indoor cable for horizontal and vertical installations
Data centre cable
Flame retardant (IEC 60332-1)
Fire retardant (IEC 60332-3)
All dielectric design
Designed for termination by splicing
Aramid yarns for ease of handling and as strength element
12 bres per Micro-Bundle
Available in 12, 24, 48 and 96 bres
Available in all bre grades
Characteristics
Mechanical characteristics
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Maximum pulling force (IEC 60794-1-2-E1)
Maximum operating pulling force
Usage characteristics
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
Fire retardant
Flame retardant
10 impacts of 1 N.m
100 N/cm
1000 N
250 N
0 .. 40 °C
-10 .. 60 °C
-20 .. 60 °C
IEC 60332-3
IEC 60332-1
Mechanical and Dimensional Characteristics for Micro-Bundle Indoor
Nb optical fibres
12
24
48
96
Nom. outer diam.
[mm]
5.4
5.4
5.4
6.4
Approx. weight
[kg/km]
37
37
37
50
static bending rad.
[mm]
65
65
65
65
Min. dynamic operating bending rad.
[mm]
80.0
80.0
80.0
100.0
N-numbers for Micro-Bundle Indoor
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
Mechanical resistance to
impacts
10 impacts of 1 N.m
Nexans ref.
N160.MBIN12
N160.MBIN24
N160.MBIN48
N160.MBIN96
N162.MBIN12
Name
LANmark-OF Micro-Bundle Indoor 12x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Micro-Bundle Indoor 24x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Micro-Bundle Indoor 48x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Micro-Bundle Indoor 96x Multimode 62,5/125 OM1 LSZH Orange
LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM2 LSZH Orange
Ambient installation
temperature, range
0 .. 40 °C
Operating temperature,
range
-10 .. 60 °C
Storage temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Page 152 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Indoor
Fiber optic type
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Mechanical resistance to
impacts
10 impacts of 1 N.m
Nexans ref.
N162.MBIN24
N162.MBIN48
N162.MBIN96
N165.MBIN12
N165.MBIN24
N165.MBIN48
N165.MBIN96
N167.MBIN12
N167.MBIN24
N167.MBIN48
N167.MBIN96
N164.MBIN12
N164.MBIN24
N164.MBIN48
N164.MBIN96
Name
LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM2 LSZH Orange
LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM3 LSZH Orange
LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM4 LSZH Orange
LANmark-OF Micro-Bundle Indoor 12x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Micro-Bundle Indoor 24x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Micro-Bundle Indoor 48x Singlemode 9/125 OS2 LSZH Yellow
LANmark-OF Micro-Bundle Indoor 96x Singlemode 9/125 OS2 LSZH Yellow
Ambient installation
temperature, range
0 .. 40 °C
Operating temperature,
range
-10 .. 60 °C
Storage temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Page 153 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Universal (24F-72F)
• Micro-Bundle Universal optical bre cable
• Indoor cable and outdoor installation in a duct
• Fully waterproof and rodent resistant
• Small, but mechancial strong cable
• Designed for splicing with pigtails
• 24-72 bres and available in all bre grades
Description
Description and Application
The new Micro-Bundle technology from Nexans allows to manufacture a exible
and small tube. This Micro-Bundle is the central part of the new “LANmark-OF
Micro-Bundle Universal” cable design. Each Micro-Bundle contains 12 bres with
a bre diameter of 250 um. Termination of these bres is done with splicing with
pigtails.
Up to 6 Micro-Bundles are arranged around a central strength element. The
combination of the Micro-Bundle technology, the central strength element and the
glass yarns result in a mechanical robust, but also in a small and exible cable.
The small bending radius of the LANmark-OF Micro-Bundle Universal makes the
cable easy to arrange in patch panels, in cable trays and in ducts.
The watertight glass yarns and the very limited amount of gel inside the tube
make the LANmark-OF Micro-Bundle Universal design watertight, rodent resistant
and suitable for installation outdoor in a duct by pulling.
Standards
International ISO/IEC 11801
The LANmark-OF Micro-Bundle Universal complies with the indoor re
requirements. Since there is no drip effect of the very limited amount of gel the
cable is optimised for both horizontal and vertical installations.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
5.
Central strength element
Optical bre (250 µm)
Micro-Bundle with 12 bres
Reinforced watertight glass yarns
Outer sheath in LSZH material with UV resistant additive
Mechanical
resistance to
impacts
10 impacts of 1
N.m
Ambient
installation
temperature,
range
0 .. 40 °C
Operating
temperature,
range
-30 .. 60 °C
Storage
temperature,
range
-30 .. 60 °C
Minimum static
operating
bending radius
75 mm
03/12/10 - http://www.nexans.co.uk
Minimum dynamic
operating bending
radius
150.0 mm
Fire
retardant
IEC
60332-3
Flame
retardant
IEC
60332-1
Page 154 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Universal (24F-72F)
Characteristics
•
•
•
•
•
•
•
•
•
•
•
Micro-Bundle design for easy installation
Indoor cable for horizontal and vertical installations
Flame retardant (IEC 60332-1)
Fire retardant (IEC 60332-3)
Outdoor cable for installation in a duct
Waterproof structure, rodent resistant and UV-resistant
All dielectric design
Designed for termination by splicing
12 bres per Micro-Bundle
Available in 24, 48 and 96 bres
Available in all bre grades
Characteristics
Dimensional characteristics
Approximate weight
Nominal outer diameter
Mechanical characteristics
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Maximum operating pulling force
Maximum pulling force (IEC 60794-1-2-E1)
Usage characteristics
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
Minimum static operating bending radius
Minimum dynamic operating bending radius
Fire retardant
Flame retardant
64 kg/km
7.2 mm
10 impacts of 1 N.m
100 N/cm
600 N
2000 N
0 .. 40 °C
-30 .. 60 °C
-30 .. 60 °C
75 mm
150.0 mm
IEC 60332-3
IEC 60332-1
N-number for Micro-Bundle Universal (24F-72F)
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
Mechanical
resistance to
impacts
10 impacts of 1
N.m
Nexans ref.
N160.MBUN24
N160.MBUN48
N160.MBUN72
N162.MBUN24
N162.MBUN48
N162.MBUN72
N165.MBUN24
Ambient
installation
temperature,
range
0 .. 40 °C
Name
LANmark-OF Micro-Bundle Universal 24x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 48x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 72x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM3 LSZH Black
Operating
temperature,
range
-30 .. 60 °C
Storage
temperature,
range
-30 .. 60 °C
Minimum static
operating
bending radius
75 mm
03/12/10 - http://www.nexans.co.uk
Minimum dynamic
operating bending
radius
150.0 mm
Fire
retardant
IEC
60332-3
Flame
retardant
IEC
60332-1
Page 155 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Universal (24F-72F)
Fiber optic type
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
Mechanical
resistance to
impacts
10 impacts of 1
N.m
Nexans ref.
N165.MBUN48
N165.MBUN72
N167.MBUN24
N167.MBUN48
N167.MBUN72
N164.MBUN24
N164.MBUN48
N164.MBUN72
Ambient
installation
temperature,
range
0 .. 40 °C
Name
LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 24x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Micro-Bundle Universal 48x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Micro-Bundle Universal 72x Singlemode 9/125 OS2 LSZH Black
Operating
temperature,
range
-30 .. 60 °C
Storage
temperature,
range
-30 .. 60 °C
Minimum static
operating
bending radius
75 mm
03/12/10 - http://www.nexans.co.uk
Minimum dynamic
operating bending
radius
150.0 mm
Fire
retardant
IEC
60332-3
Flame
retardant
IEC
60332-1
Page 156 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Universal (4F-12F)
• Micro-Bundle Universal optical bre cable
• Indoor cable and outdoor installation in a duct
• Fully waterproof and rodent retardant
• Designed for splicing with pigtails
• 4-12 bres and available in all bre grades
Description
Description and Application
The new Micro-Bundle technology from Nexans allows to manufacture a very
exible and small tube that is the central part of the new “LANmark-OF MicroBundle Universal” cable design. This results in a small, exible, but mechanical
robust cable. The central tube contains up till 12 bres with a bre diameter of
250 um. Termination of these bres is done with splicing with pigtails.
The small bending radius of the Micro-Bundle makes the cable easy to arrange in
patch panels and for installations in data centres and backbones.
The watertight glass yarns and the very limited amount of gel inside the tube
makes this cable design watertight and suitable for installation outdoor in a duct
by pulling.
The re performance of the LANmark-OF Micro-Bundle Universal allows indoor
installation as well. Since there is no drip effect of the very limited amount of gel
the cable is optimised for both horizontal and vertical installations.
Construction
1.
2.
3.
4.
5.
Standards
Central Micro-Bundle
Gel
Reinforced watertight glass yarns
Ripcord
LSZH outer jacket with UV resistant additive
International ISO/IEC 11801
Characteristics
•
•
•
•
•
•
•
•
Indoor cable for horizontal and vertical installation
Outdoor cable for installation in a duct
Designed for termination by splicing
Central Micro-Bundle design for easy installation
All dielectric
Waterproof structure, Rodent retardant and UV-resistant
Flame retardant (IEC 60332-1) and re retardant (IEC 60331-3)
Available in all bre grades and from 4-12 bres
Mechanical
resistance to
impacts
1 impact of 3
N.m
Flame
retardant
IEC
60332-1
Fire
retardant
IEC
60332-3
Ambient
installation
temperature,
range
0 .. 40 °C
Operating
temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage
temperature,
range
-40 .. 60 °C
Minimum static
operating
bending radius
60 mm
Minimum dynamic
operating bending
radius
60.0 mm
Page 157 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Micro-Bundle Universal (4F-12F)
Characteristics
Dimensional characteristics
Approximate weight
Nominal outer diameter
Mechanical characteristics
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Maximum operating pulling force
Maximum pulling force (IEC 60794-1-2-E1)
Usage characteristics
Flame retardant
Fire retardant
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
Minimum static operating bending radius
Minimum dynamic operating bending radius
42 kg/km
5.6 mm
1 impact of 3 N.m
200 N/cm
700 N
2200 N
IEC 60332-1
IEC 60332-3
0 .. 40 °C
-20 .. 60 °C
-40 .. 60 °C
60 mm
60.0 mm
N-numbers for Micro-Bundle Universal
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Nexans ref.
N160.MBUN04
N160.MBUN06
N160.MBUN08
N160.MBUN12
N162.MBUN04
N162.MBUN06
N162.MBUN08
N162.MBUN12
N165.MBUN04
N165.MBUN06
N165.MBUN08
N165.MBUN12
N167.MBUN04
N167.MBUN06
N167.MBUN08
N167.MBUN12
N164.MBUN04
N164.MBUN06
N164.MBUN08
N164.MBUN12
Name
LANmark-OF Micro-Bundle Universal 4x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 6x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 8x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 12x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM2 LSZH Black
LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM3 LSZH Black
LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM4 LSZH Black
LANmark-OF Micro-Bundle Universal 4x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Micro-Bundle Universal 6x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Micro-Bundle Universal 8x Singlemode 9/125 OS2 LSZH Black
LANmark-OF Micro-Bundle Universal 12x Singlemode 9/125 OS2 LSZH Black
03/12/10 - http://www.nexans.co.uk
Page 158 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UD PE
• UD optical bre cables
• Suitable for outdoor in ducts or direct burial
• Full dielectric armour
• Available in all bre grades and till 24 bres
• Rodent resistance
Description
Description and Application
The LANmark-OF UD PE cable is designed as a campus cable. It can be pulled
in a duct outside or can be direct buried. Its full dielectric armouring does not
provide an electrical path and hence the cable can be used to connect 2
buildings.
The central loose tube is surrounded by robust strength elements: Fibre
Reinforced Plastic (FRP) elements. These FRP provide the cable with a high
rodent resistant and a high resistant against impacts and compression. There are
4 x FRP and 5 x llers for bre counts 4-12. For 14-24 bres there are 5 X FRP
and 5 X llers.
The loose tube design has a capacity of up to 24 bres. Diameter of the bres is
250 um. Termination of these bres is done with splicing of pigtails.
The cable is watertight due to the gel in the loose tube and the watertight glass
yarns.
Standards
International ISO/IEC 11801
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
5.
6.
7.
Optical bres (250 um)
Gel
Loose tube
Fillers
Fibre Reinforced Plastic strength elements
Reinforced watertight glass yarns
PE outer jacket with UV resistant additive
Characteristics
Ambient installation temperature, range
0 .. 40 °C
Operating temperature, range
-30 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage temperature, range
-40 .. 70 °C
Page 159 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UD PE
•
•
•
•
•
•
•
•
Outdoor cable for installation in a duct or direct burial
Designed for termination by splicing
Central loose tube design
All dielectric design with FRP reinforcement and glass yarns
Waterproof structure, rodent resistant and UV-resistant
Available in all bre grades
Available from 4-24 bres
Excellent friction properties
Characteristics
Usage characteristics
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
0 .. 40 °C
-30 .. 60 °C
-40 .. 70 °C
Mechanical and Dimensional Characteristics for LANmark-OF UD PE
Min. dynamic
Approx.
operating
weight
bending rad.
[kg/km]
[mm]
static
bending
rad.
[mm]
Crush
resistance Mechanical
(IEC 60794-1- resistance to
impacts
E3)
[N/cm]
Nb
optical
fibres
Nom.
outer
diam.
[mm]
4
8.1
50
205.0
160
300
6
8.1
50
205.0
160
300
8
8.1
50
205.0
160
300
12
8.1
50
205.0
160
300
24
9,1
73
225,0
180
400
Maximum
pulling force
Maximum
(IEC
operating
60794-1-2- pulling force
E1)
[N]
[N]
100 impacts of
3 N.m
100 impacts of
3 N.m
100 impacts of
3 N.m
100 impacts of
3 N.m
100 impacts of
5 N.m
1150
560
1150
560
1150
560
1150
560
1450
700
N-numbers for LANmark-OF UD PE
Nexans ref.
N160.681
N160.682
N160.683
N160.685
N160.691
N162.681
N162.682
N162.683
Ambient installation temperature, range
0 .. 40 °C
Name
LANmark-OF UD 4x Multimode 62,5/125 OM1 PE Black
LANmark-OF UD 6x Multimode 62,5/125 OM1 PE Black
LANmark-OF UD 8x Multimode 62,5/125 OM1 PE Black
LANmark-OF UD 12x Multimode 62,5/125 OM1 PE Black
LANmark-OF UD 24x Multimode 62,5/125 OM1 PE Black
LANmark-OF UD 4x Multimode 50/125 OM2 PE Black
LANmark-OF UD 6x Multimode 50/125 OM2 PE Black
LANmark-OF UD 8x Multimode 50/125 OM2 PE Black
Operating temperature, range
-30 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage temperature, range
-40 .. 70 °C
Page 160 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UD PE
Nexans ref.
N162.685
N162.691
N164.681
N164.682
N164.683
N164.685
N164.691
N165.681
N165.682
N165.683
N165.685
N165.691
N167.681
N167.682
N167.683
N167.685
N167.691
Ambient installation temperature, range
0 .. 40 °C
Name
LANmark-OF UD 12x Multimode 50/125 OM2 PE Black
LANmark-OF UD 24x Multimode 50/125 OM2 PE Black
LANmark-OF UD 4x Singlemode 9/125 OS2 PE Black
LANmark-OF UD 6x Singlemode 9/125 OS2 PE Black
LANmark-OF UD 8x Singlemode 9/125 OS2 PE Black
LANmark-OF UD 12x Singlemode 9/125 OS2 PE Black
LANmark-OF UD 24x Singlemode 9/125 OS2 PE Black
LANmark-OF UD 4x Multimode 50/125 OM3 PE Black
LANmark-OF UD 6x Multimode 50/125 OM3 PE Black
LANmark-OF UD 8x Multimode 50/125 OM3 PE Black
LANmark-OF UD 12x Multimode 50/125 OM3 PE Black
LANmark-OF UD 24x Multimode 50/125 OM3 PE Black
LANmark-OF UD 4x Multimode 50/125 OM4 PE Black
LANmark-OF UD 6x Multimode 50/125 OM4 PE Black
LANmark-OF UD 8x Multimode 50/125 OM4 PE Black
LANmark-OF UD 12x Multimode 50/125 OM4 PE Black
LANmark-OF UD 24x Multimode 50/125 OM4 PE Black
Operating temperature, range
-30 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage temperature, range
-40 .. 70 °C
Page 161 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UC PE
UC optical bre cables
•
•
•
•
Outdoor in ducts or direct burial
Corrugated steel tape armour
Available in all bres grades
Provides full rodent protection
Description
Description and Application
The construction is suitable for use outdoor in ducts and for direct burial. It
consists of a corrugated steel tape armouring providing full rodent protection. It is
surrounded by glass yarns. The cable has a HDPE outer jacket.
The loose tube design has a capacity of up to 24 bres. Diameter of the bres is
250 um. Termination of these bres is done with splicing of pigtails.
The cable is watertight due to the gel in the loose tube and the watertight glass
yarns.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
5.
6.
Optical bres (250 um)
Gel
Loose tube
Reinforced watertight glass yarns
Corrugated steel tape armour
PE outer jacket with UV resistant additive
Standards
International ISO/IEC 11801
Characteristics
•
•
•
•
•
•
•
Outdoor cable for installation in a duct or direct burial
Designed for termination by splicing
Central loose tube design
Corrugated steel protection
Waterproof structure, rodent resistant and UV-resistant
Available in all bre grades
Available from 4-24 bres
Mechanical
resistance to
impacts
100 impacts of 3
N.m
Minimum dynamic
operating bending radius
200.0 mm
Minimum static
operating bending
radius
140 mm
Operating
temperature, range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage
temperature, range
-30 .. 60 °C
Ambient installation
temperature, range
0 .. 40 °C
Page 162 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UC PE
Characteristics
Dimensional characteristics
Nominal outer diameter
Approximate weight
Mechanical characteristics
Mechanical resistance to impacts
Maximum pulling force (IEC 60794-1-2-E1)
Maximum operating pulling force
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Minimum dynamic operating bending radius
Minimum static operating bending radius
Operating temperature, range
Storage temperature, range
Ambient installation temperature, range
9.5 mm
100 kg/km
100 impacts of 3 N.m
1500 N
450 N
300 N/cm
200.0 mm
140 mm
-20 .. 60 °C
-30 .. 60 °C
0 .. 40 °C
N-numbers for LANmark-OF UC PE
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Nexans ref.
N160.181
N160.182
N160.183
N160.185
N160.191
N162.181
N162.182
N162.183
N162.185
N162.191
N165.181
N165.182
N165.183
N165.185
N165.191
N167.181
N167.182
N167.183
N167.185
N167.191
N164.181
N164.182
N164.183
N164.185
N164.191
Name
LANmark-OF UC 4x Multimode 62,5/125 OM1 PE Black
LANmark-OF UC 6x Multimode 62,5/125 OM1 PE Black
LANmark-OF UC 8x Multimode 62,5/125 OM1 PE Black
LANmark-OF UC 12x Multimode 62,5/125 OM1 PE Black
LANmark-OF UC 24x Multimode 62,5/125 OM1 PE Black
LANmark-OF UC 4x Multimode 50/125 OM2 PE Black
LANmark-OF UC 6x Multimode 50/125 OM2 PE Black
LANmark-OF UC 8x Multimode 50/125 OM2 PE Black
LANmark-OF UC 12x Multimode 50/125 OM2 PE Black
LANmark-OF UC 24x Multimode 50/125 OM2 PE Black
LANmark-OF UC 4x Multimode 50/125 OM3 PE Black
LANmark-OF UC 6x Multimode 50/125 OM3 PE Black
LANmark-OF UC 8x Multimode 50/125 OM3 PE Black
LANmark-OF UC 12x Multimode 50/125 OM3 PE Black
LANmark-OF UC 24x Multimode 50/125 OM3 PE Black
LANmark-OF UC 4x Multimode 50/125 OM4 PE Black
LANmark-OF UC 6x Multimode 50/125 OM4 PE Black
LANmark-OF UC 8x Multimode 50/125 OM4 PE Black
LANmark-OF UC 12x Multimode 50/125 OM4 PE Black
LANmark-OF UC 24x Multimode 50/125 OM4 PE Black
LANmark-OF UC 4x Singlemode 9/125 OS2 PE Black
LANmark-OF UC 6x Singlemode 9/125 OS2 PE Black
LANmark-OF UC 8x Singlemode 9/125 OS2 PE Black
LANmark-OF UC 12x Singlemode 9/125 OS2 PE Black
LANmark-OF UC 24x Singlemode 9/125 OS2 PE Black
03/12/10 - http://www.nexans.co.uk
Page 163 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UC LSZH
UC optical bre cables
•
•
•
•
•
•
Indoor/Outdoor cable
Corrugated steel tape armour
Gel lled tube
All bre grades
Provides full rodent protection
Low Smoke Zero Halogene (LSZH)
Description
Description and Application
The construction is suitable for indoor/outdoor use. It consists of a corrugated
steel tape armouring providing full rodent protection. It is surrounded by glass
yarns. The cable has a LSZH outer jacket.
The loose tube design has a capacity of up to 24 bres. Diameter of the bres is
250 um. Termination of these bres is done with splicing of pigtails.
The cable is watertight due to the gel in the loose tube and the watertight glass
yarns.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
4.
5.
6.
Optical bres (250 um)
Gel
Loose tube
Reinforced watertight glass yarns
Corrugated steel tape armour
LSZH outer jacket with UV resistant additive
Standards
International ISO/IEC 11801
Characteristics
•
•
•
•
•
•
•
•
Indoor/Outdoor cable
Flame and re non propagation
Designed for termination by splicing
Central loose tube design
Corrugated steel protection
Waterproof structure, rodent resistant and UV-resistant
Available in all bre grades
Available from 4-24 bres
Mechanical
resistance to
impacts
100 impacts of
3 N.m
Minimum dynamic
operating bending
radius
210.0 mm
Minimum static
operating
bending radius
150 mm
Ambient
installation
temperature,
range
0 .. 40 °C
Operating
temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Storage
temperature,
range
-30 .. 60 °C
Fire
retardant
IEC
60332-3
Flame
retardant
IEC
60332-1
Page 164 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF UC LSZH
Characteristics
Dimensional characteristics
Approximate weight
Nominal outer diameter
Mechanical characteristics
Maximum pulling force (IEC 60794-1-2-E1)
Maximum operating pulling force
Mechanical resistance to impacts
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Minimum dynamic operating bending radius
Minimum static operating bending radius
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
Fire retardant
Flame retardant
129 kg/km
9.5 mm
1500 N
450 N
100 impacts of 3 N.m
300 N/cm
210.0 mm
150 mm
0 .. 40 °C
-20 .. 60 °C
-30 .. 60 °C
IEC 60332-3
IEC 60332-1
N-numbers for LANmark-OF UC LSZH
Fiber optic type
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM1 62.5/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM2 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM3 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
OM4 50/125
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
SM (G.652D)
Nexans ref.
N160.471
N160.472
N160.473
N160.475
N160.481
N162.471
N162.472
N162.473
N162.475
N162.481
N165.471
N165.472
N165.473
N165.475
N165.481
N167.471
N167.472
N167.473
N167.475
N167.481
N164.471
N164.472
N164.473
N164.475
N164.481
Name
LANmark-OF UC 4x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF UC 6x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF UC 8x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF UC 12x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF UC 24x Multimode 62,5/125 OM1 LSZH Black
LANmark-OF UC 4x Multimode 50/125 OM2 LSZH Black
LANmark-OF UC 6x Multimode 50/125 OM2 LSZH Black
LANmark-OF UC 8x Multimode 50/125 OM2 LSZH Black
LANmark-OF UC 12x Multimode 50/125 OM2 LSZH Black
LANmark-OF UC 24x Multimode 50/125 OM2 LSZH Black
LANmark-OF UC 4x Multimode 50/125 OM3 LSZH Black
LANmark-OF UC 6x Multimode 50/125 OM3 LSZH Black
LANmark-OF UC 8x Multimode 50/125 OM3 LSZH Black
LANmark-OF UC 12x Multimode 50/125 OM3 LSZH Black
LANmark-OF UC 24x Multimode 50/125 OM3 LSZH Black
LANmark-OF UC 4x Multimode 50/125 OM4 LSZH Black
LANmark-OF UC 6x Multimode 50/125 OM4 LSZH Black
LANmark-OF UC 8x Multimode 50/125 OM4 LSZH Black
LANmark-OF UC 12x Multimode 50/125 OM4 LSZH Black
LANmark-OF UC 24x Multimode 50/125 OM4 LSZH Black
LANmark-OF UC 4x Singlemode 9/125 OS2 LSZH Black
LANmark-OF UC 6x Singlemode 9/125 OS2 LSZH Black
LANmark-OF UC 8x Singlemode 9/125 OS2 LSZH Black
LANmark-OF UC 12x Singlemode 9/125 OS2 LSZH Black
LANmark-OF UC 24x Singlemode 9/125 OS2 LSZH Black
03/12/10 - http://www.nexans.co.uk
Page 165 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cables - LANmark-OF ZC LSZH
ZipCord optical bre cables
•
•
•
•
Designed for direct termination on ST, SC or LC connectors
Suitable for indoor use in horizontal cabling and risers
Suitable for use in patch assembly
Available in all bre grades
Description
Application
LANmark-OF ZC optical bre cables have been designed for applications where a
high level of installation, environmental and optical performance is required. The
ZipCord range is most suitable for direct termination in patch assembly and in
risers and horizontal cabling.
The majority of the tight buffered cables are suitable for both internal & external
environments and are all dielectric with excellent ame retardance
Applications support :
•
•
•
•
•
•
•
•
FDDI 100 Mbps
Ethernet 10 base FL
Fast Ethernet 100 base FX
Gbit Ethernet 1000 base SX/LX
10Gbit Ethernet 10000 base SX(*)
Fibre Channel 1.0625 Gbps
ATM 155 Mbps
ATM 622 Mbps
(*) in accordance with IEEE 802.3ae
Standards
International ISO/IEC 11801
Performance
LANmark-OF Tight Buffered optical bre cables are available with standard
multimode & singlemode bres whilst the LANmark-OFxt ranges are supplied with
Laser Optimised multimode bres offering extended application distances for
Gigabit Ethernet.
Construction
Legend accompanying the cross section drawing:
1.
2.
3.
900 µm tight buffered bre
Aramid yarns reinforcement
Flame retardant halogen free outer sheath
Flame retardant
IEC 60332 Part 3 Cat. C
Ambient installation temperature,
range
0 .. 40 °C
Operating temperature, range
-10 .. 70 °C
03/12/10 - http://www.nexans.co.uk
Storage temperature, range
-30 .. 70 °C
Page 166 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cables - LANmark-OF ZC LSZH
Characteristics
Construction characteristics
Type of cable
Armour type
Material of ller / inner sheath
Outer sheath
Dimensional characteristics
Number of optical bres
Height
Width
Approximate weight
Mechanical characteristics
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Installation type
Flame retardant
Ambient installation temperature, range
Operating temperature, range
Storage temperature, range
Product List
Nexans ref.
N162.001
N163.001
N165.001
N166.001
N160.001
N161.001
N164.001
Zip Cord (ZC)
Unarmoured
Aramid yarn
LSZH-FR
2
2.8 mm
5.8 mm
14 kg/km
300 N/cm
Indoor
IEC 60332 Part 3 Cat. C
0 .. 40 °C
-10 .. 70 °C
-30 .. 70 °C
=Make to order,
=Make to stock
Name
Fiber optic type
LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM2 LSZH Orange
OM2 50/125
LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM2xt LSZH Orange
OM2 50/125 Extended Distance
LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM3 LSZH Orange
OM3 50/125
LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM3xt LSZH Orange
OM3 50/125 Extended Distance
LANmark-OF ZC (2,8mm) 2x Multimode 62,5/125 OM1 LSZH Orange
OM1 62.5/125
LANmark-OF ZC (2,8mm) 2x Multimode 62,5/125 OM1xt LSZH Orange OM1 62.5/125 Extended Distance
LANmark-OF ZC (2,8mm) 2x Singlemode 9/125 OS2 LSZH Yellow
SM (G.652D)
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 167 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre Connectors & Connector Accessories
LANmark-OF offers cutting edge connectivity products including connectors,
couplers, pigtails, patch cords,…
Each product has been thoroughly developed to ensure best system offering
while meeting stringent international standards.
Small Form Factor products
Full range of pigtails, patchcords and adaptors supporting both small form factor
MT-RJ and LC connectors as well as ST and SC connectors.
Snap-in concept
Nexans ‘snap-in’ format allows quick and easy installation without screws. They
are available in SC format as well as the small form factor LC and MT-RJ
connectors.
03/12/10 - http://www.nexans.co.uk
Page 168 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Connectors
• Connector for on-site termination
• Installed using the Nexans anaerobic toolkit
• Suitable for installation on 900µm bre as well as on cable
Description
Nexans offers a large range of Fibre Optics connectors for eld termination
practices. All these connectors meet most recent standard ISO 11801 releases.
Connector type available :
• SC
• ST
• LC
For optimal installations, Nexans recommends to use its Anaerobic Toolkit (ref.:
102.220). This toolkit provides a comprehensive set of tools and consumables for
easier on-site jobs and is supplied with illustrated installation manual.
Standards
International ISO/IEC 11801
Product List
Nexans
ref.
N102.461
N102.462
N205.120
N205.121
N890.008
N205.630
N205.631
Name
LANmark-OF ST Connector Anaerobic Multimode for 900µm /2.8mm
LANmark-OF Simplex SC Connector Multimode for 900µm / 2.8mm
(3M Hot Melt)
LANmark-OF Simplex SC Connector Anaerobic Multimode for 900µm
/2.8mm
LANmark-OF Simplex ST Connector Multimode for 900µm / 2.8mm
(3M Hot Melt)
LANmark-OF Simplex SC Connector Singlemode for 900µm / 2.8mm
(3M Hot Melt)
LANmark-OF Simplex LC Connector Anaerobic Multimode for 900µm
LANmark-OF Simplex LC Connector Anaerobic Multimode for
1.6-2.2mm
=Make to order,
=Make to stock
Fiber optic type
Connector
type
Multimode
ST
Multimode
SC
Multimode
SC
Multimode
ST
SingleMode
9/125
Multimode
Multimode
= Make to order,
03/12/10 - http://www.nexans.co.uk
SC
LC
LC
= Make to stock
Page 169 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Connector Accessories
Description
Tools & accessories for termination of Nexans connectors
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 170 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Connector Accessories
Product List
Nexans ref.
N102.221
N102.214
N102.220
N102.222
N102.224
N102.223
N102.225
N102.226
=Make to order,
=Make to stock
Name
Adhesive & Activator for Anaerobic Connector
LANmark-OF Toolkit for Anaerobic Connector (extension to hotmelt kit )
LANmark-OF Toolkit for Anaerobic Connector (starter kit)
Polishing Paper 1 micron for Anaerobic Toolkit (50/bag)
Polishing Paper 12 micron for Anaerobic Toolkit (10/bag)
Polishing Paper 3 micron for Anaerobic Toolkit (50/bag)
Syringes for Anaerobic Toolkit (50/box)
Wipes for Anaerobic Toolkit (100/box)
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 171 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Pre-Terminated Fibre Assemblies
This added-value offer enables fast network deployment and removes the
requirement for specialized termination training, consumables and toolkits. Every
assembly is developed and manufactured by optical engineers to individual
customer requirements: cable length, connector type, bre grade, fanouts size, …
All LANmark-OF Pre-Term assemblies are fully terminated and tested in a quality
assured factory environment. They are delivered with test results and benet from
the 25 year LANmark-OF warranty program.
LANmark-OF Pre-Term signicantly reduces installation time and cost while
guaranteeing full scalability and long lasting reliability for every situation whether
campus, backbone, Local/Storage Area Network or Data Centre.
03/12/10 - http://www.nexans.co.uk
Page 172 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly
Factory Pre-terminated assemblies which combine ease of installation and outstanding performances. 100% customised for
your needs, this product meet the most demanding lead-times.
Description
The solution consist of universal indoor cable assembled in factory with
connectors at each end. Any type of connectors can be used for the assembly:
ST, SC, LC, MTRJ, etc. Fibre types available: Single mode 9/125µm (OS2 cables
with G652D bres) and laser optimised 50/125µm OM3 or OM4 bres. A pulling
eye system is positioned at the end of the cable to protect the terminations while
pulling the cable. When the cable has been installed, the pulling eye system is cut
off and the terminated bres are fed into a patch panel. Since the assembly is
done in factory, all pre-terminated bre optic cables are 100% tested and
supplied with test results.
Applications
Interbuilding and Intrabuilding backbones for Local Area Network (LAN) Premise
and Campus applications. Horizontal bre distribution to work area and zone.
Equipment distribution area trunk cables for Data centre and Storage Area
Network (SAN) applications.
Standards
International ISO/IEC 11801
Applications support :
•
•
•
•
•
Ethernet 10 base FL
Fast Ethernet 100 base FX
Gigabit Ethernet 1000 base SX/LX
10 Gigabit Ethernet 10G Base SX/LX
1-2-4-10 Gbps Fibre Channel
Fibre types
The Pre-Terms are available with singlemode (9/125 um) bre with G652D bres.
This results in OS2 cables.
For multimode laser optimised bres (50/125 um) are available with OM3 or OM4
performance.
Details with the exact optical performance can be found in the specic bre
datasheets.
Benefits
•
•
•
•
•
•
•
•
•
•
•
•
•
Short & reliable manufacturing lead-time
Fast installation times
No specialised termination training required
No consumables, termination tool kits
No cable preparation necessary
No cable or connector scrap
No termination errors on site
Delivered fully tested, labelled and documented
High performing connectors: Max IL 0,40dB*
Improved end-to-end attenuation
Improved application migration
Reduced on-site disruption and installation time
Highly cost effective solution
*For LC-SC-ST
03/12/10 - http://www.nexans.co.uk
Page 173 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly
Tailor made solution
Nexans LANmark-OF pre-term solutions are 100% tailor made solutions. You
specify your cable and connectivity requirements and our optical engineers
develop and manufacture your end-to-end pre-terminated cable solution.
What needs to be specied:
1. Cable type Singlemode OS2-OM3-OM4
2. Fibre count: 6-12-24
3. cable length between enclosures
4. Fanout size (900µ or 2.0 mm)
5. Connector type on each end LC-MTRJ- SC-ST
6. Use of pulling system
Consistent quality
In order to produce high quality, reliable pre-terminated multi-bre cables, there
are a number of physical characteristics that must be addressed. Therefore, all
LANmark-OF Pre-term assemblies are fully terminated and tested in a quality
assured factory environment. They are delivered with test results protocol and
benet from the 25 years LANmark-OF warranty program.
03/12/10 - http://www.nexans.co.uk
Page 174 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly
LANmark-OF Pre-Term specications
Cable Specifications
Fibre count
Diameter
Sheath
Min. bending radius
6
12
24
6,10mm
6,60mm
8,1mm
LSZH
LSZH
LSZH
150 mm
150 mm
150 mm
Fibre count
Max Pulling force
Compression
Impacts
Temp.range
6
12
24
100daN
140daN
140daN
100daN/dm
100daN/dm
100daN/dm
100 impacts of 1 N.m
100 impacts of 1 N.m
100 impacts of 1 N.m
-20°C +60°C
-20°C +60°C
-20°C +60°C
Stand. Min RL
LANmark-OF Pre-Term
Measurement Standard Me
chanical Performances
Min.bending radius
IEC-60794-1-E10
Maximum pulling force
IEC-60794-1-E1
Compression
IEC-60794-1-E3
Impacts
IEC-60794-1-E4
Operating temperatures
IEC-60794-1-F1
Connector specifications
Type
Multimode
SC/PC
LC/PC
ST/PC
MT-RJ/PC
Single Mode
SC/PC
LC/PC
ST/PC
MT-RJ/PC
Standard Max IL LANmark-OF Pre-term
0,75 dB
0,75 dB
0,75 dB
0,75 dB
0.35 dB
0.35 dB
0.35 dB
0.35 dB
20dB
20dB
20dB
20dB
35 dB
35 dB
35 dB
35 dB
0,75 dB
0,75 dB
0,75 dB
0,75 dB
0.35 dB
0.35 dB
0.35 dB
0.35 dB
20dB
20dB
20dB
20dB
50 dB
50 dB
50 dB
35 dB
03/12/10 - http://www.nexans.co.uk
Page 175 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly
N-number codication: N155F.TAACFCFPXXX
4: Singlemode (OS2) with G652D
F: Fibre type
5: OM3 bre
7: OM4 bre
06: 6 bres
AA: bre count
12: 12 bres
24: 24 bres
L: LC
C: Connector type
C: SC
T: ST
M: MTRJ
F: Fan-out type
9: 900 um fanout
2: 2.0 mm fanout
A: one side
P: pulling eye
Y: both sides
N: no pulling eye
XXX
length in meter
03/12/10 - http://www.nexans.co.uk
Page 176 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
MPO System
MPO-concept
The Nexans’ Plug&Play concept is specially designed for the LAN and data
centre environment. It facilitates fast installation of a large number of bre
connections, high density, quick changes with limited down time and an easy
migration path to future applications.
The Plug&Play system consists of 3 subcomponents: the MPO-MPO Pre-Term,
the Plug&Play modules and the Plug&Play patch panel.
The MPO-MPO Pre-Term provides the connectivity between 2 Plug&Play
modules installed in the Plug&Play patch panels in 2 different racks. The MPO
connector allows to quickly connecting the 12 bres of the MPO-MPO Pre-Term at
the back of each Plug&Play module. Inside the Plug&Play module the bres are
spread out towards the SC/LC connectors at the front.
Optical performance and polarity method
Nexans’ Plug&Play modules and bre assemblies are available in 2 performance grades: LANmark-OF MPO connectivity
and the newly introduced LANmark-OF MPO low loss connectivity. With the low loss connectivity insertion loss has been
reduced by 40 %. It enables more complex data centre conguarations, extended reach, more head room and a migration
path to 40G/100G.
The bre assemblies are available as LANmark-OF OM3 and LANmark-OF OM4 for extended reach. The Plug&Play
modules have LANmark-OF OM4 performance and are backwards compatible with LANmark-OF OM3.
With LANmark-OF OM4 and the low loss solution up to 8 modules can be installed for an operational 10G channel. For
40G/100G a 4 connector channel up to 120 m can be supported.
Polarity in the optical channel during installation is guaranteed due to a pair ip bre construction. This is in agreement with
standard TIA 568-B-1-7-2006 method C. It allows the continuous use of the standard patch cord eliminating the need to buy
optically straight and crossed patch cords. Also polarity is maintained with the same type of cassette on both sides of the
channel without the need to ip the cassette on one side.
Pre-Term assemblies
The Pre-Term assemblies are based on the advanced Micro-Bundle technology. A Micro-Bundle is a small and very exible
tube with 12 bres and it is the central part of a range of new cable designs. With its small diameter and short bending
radius Micro-Bundle cables meet the tight space requirements in data centres.
The Micro-Bundle technology has extremely low skew by its advanced manufacturing process and small diameter. The
Pre-Term assemblies easily exceed the skew requirements for 40G and 100G Ethernet.
With the high bre count of the Pre-Term trunk assemblies the number of installed cables in a data centre can be reduced.
The Pre-Terms trunks are available in 12, 24, 48 and 96 bre counts. The trunk assemblies are very robust due to its
central strength element and the aramid yarns, but have still a small diameter of maximum 6.4 mm and a small bending
radius of maximum 65 mm. The very exible MPO fan-out is easy to install in a patch panel. Additional features are a
pulling eye and a protective tube.
The slim Pre-Term is available as a 12 core assembly. The small diameter of this solution makes it the preferred solution
when space constraints in the cable trays and the racks are key concerns.
To allow the customer the full choice of conguration options cable assemblies are offered with both normal and low loss
connectors. The assemblies are available in both LANmark-OF OS2, OM3 and OM4.
Plug&Play Patch Panel and modules
The new Plug&Play patch panels accommodate high density patching with installation of up to 4 Plug&Play modules. A
maximum of 96 LC connections can be installed in one height unit. The patch panels are sliding and have an integrated
patch cord guide that sits in front of the modules.
03/12/10 - http://www.nexans.co.uk
Page 177 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
One patch panel (N441.2MPP) is optimised for the installation of the slim Pre-Term. The newly introduced Plug&Play patch
panel (N439.3MPP) has optimised slots in the back of the panel for the xation of the Pre-Term trunks with cable glands.
The modules are available in 3 congurations: 12 SC, 12 LC and 24 LC. Modules with 24 LC connections support very high
density solutions, while a module with 12 LC adaptors facilitates the patching.
Modules are available in Singlemode OS2 and multimode LANmark-OF OM4, both in normal LANmark-OF MPO
connectivity and low loss performance.
03/12/10 - http://www.nexans.co.uk
Page 178 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2,
OM3 and OM4
•
•
•
•
•
•
•
•
•
Factory terminated MPO-MPO bre assembly
Flexible fan-out for ease of installation in patch panel
Small cable diameter reduces required data centre space
Polarity in optical channel is easily maintained by its advanced design
Only one type of patch cords and one type of cassettes required
Fibre count between 12 and 96
Strong bre assembly with pulling eye
Fibre type: Singlemode (OS2), OM3 and OM4
LANmark-OF MPO and low loss MPO connectivity performance
Description
MPO-MPO Pre-Term characteristics
The Pre-Term is based on an advanced Micro-Bundle design for the cable. The
central strength element and the aramid yarns result in a mechanical strong
cable, while the Micro-Bundle allow to reduce the diameter of the cable.
This round cable design facilitates the installation of the MPO-MPO Pre-Term: the
small bending radius in any direction eliminates the problems of preferential
bending associated with traditional ribbon MPO cables.
The small diameter of 5.4 mm for cables up to 48 bres and of 6.4 mm for the
cable with 96 bres of the cable reduces signicantly the expensive space
required for cabling in a data centre and facilitates the airow. The small diameter
also reduced the weight of the cable putting less requirements on the cable trays.
The Pre-Term is delivered with protecting tubes around the installed MPOconnectors and with a pulling eye on one side. This pulling eye is connected to
the internal strength element of the cable.
The MPO fan-out starts at 50 cm from the cable grand and every next connector
is 12 cm further away from the cable gland. For the 96 core the MPO connectors
are grouped by 2 for easy installation in the patch panel and the distance between
2 pairs of MPO connectors is 12 cm.
Standards
International ISO11801:2002/
A1:2008
The Pre-Term is available with OM3, OM4 and singlemode bres. The
singlemode bres are according the speciactions for G652D and OS2 cables.
Details on the bre specications can be found in the detailed bre datasheets.
The typical value for the insertion loss for a normal loss MPO-MPO connection is
0,3 dB. The limit value is 0,6 dB measured according to standard IEC61300-3-45.
The typical value for the insertion loss for a low loss MPO-MPO connection is 0,2
dB. The limit value is 0,35 dB measured according to standard IEC61300-3-45.
Polarity in the optical channel during installation is guaranteed due to a pair ip
bre construction. This is in agreement with standard TIA 568-B-1-7-2006
method C. It allows the continuous use of the standard patch cords eliminating
the need to buy optically straight patch cords. Also polarity is maintained with the
same type of cassette on both sides of the channel without the need to ip the
cassette on one side.
The MPO-MPO Pre-Term has standard non-pinned (female) connectors. This
Mechanical resistance to
impacts
10 impacts of 1 N.m
Operating temperature,
range
-10 .. 60 °C
Storage temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Page 179 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2,
OM3 and OM4
matches with the pinned (male) connectors in the MPO cassettes.
The Pre-Term meets the requirements for ame non propagation (IEC 60332-1)
and re non-propagation (IEC 60332-3). The outer jacket of the pre-term is
LSZH.
The MPO-MPO Pre-Term are custom made to the required customer length.
Consistent quality
In order to produce high quality, reliable pre-terminated multi-bre cables, there
are a number of physical characteristics that must be addressed. Therefore, all
LANmark-OF MPO-MPO Pre-Term are fully terminated and tested in a quality
assured factory environment. They are delivered with these test results.
Characteristics
Mechanical characteristics
Maximum tensile load
Max. Load. Long Term
Crush resistance (IEC 60794-1-E3)
Mechanical resistance to impacts
Usage characteristics
Operating temperature, range
Storage temperature, range
Fire retardant
Flame retardant
Mechanical resistance to
impacts
10 impacts of 1 N.m
1000 N
250.0 N
100 N/cm
10 impacts of 1 N.m
-10 .. 60 °C
-20 .. 60 °C
IEC 60332-3
IEC 60332-1
Operating temperature,
range
-10 .. 60 °C
Storage temperature,
range
-20 .. 60 °C
03/12/10 - http://www.nexans.co.uk
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Page 180 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2,
Insertion loss for individual MPO connection
OM3 and OM4
Fibre type
Multimode (OM3 or OM4) Singlemode (OS2 with G652D)
Normal loss connection -Typical loss
0.3 dB
0.3 dB
Normal loss connection - Max loss
0.6 dB
0.6 dB
Low loss connection - Typical loss
0.15 dB
0.15 dB
Low loss connection - Max loss
0.35 dB
0.35 dB
Meausured in manufacturing according to standard IEC 61300-3-45
N-number codication: N15A.MKKPVXXX
Letter in N-number Description
Variations
A
Fibre type
4: SM (OS2) or 5: OM3, 7: OM4
KK
Fibre count
12,24, 48 or 96
P
Performance
Normal (S) or low loss (L)
A: pulling eye one side + rst MPO at 50 cm + sequential MPO every 12 cm (
12, 24 and 48 bres)
V
Fanout type
XXX
Length between glands 001-300 m
E: pulling eye one side + rst 2 MPO at 50 cm + sequential 2 MPO every 12 c
m (96 bres)
Example: N155.M48LA050: LANmark-OF MPO-MPO Pre-Term with 48 OM3 bres, low loss connectors, pulling eye on one
side, rst MPO connector at 50 cm from cable gland and with a length of 50 m between the cable glands
Cable Characteristics
Fibre count
Cable Daimeter
Cable Weight (kg/km)
12F/24F/48F
96F
5.4 mm
6.4 mm
31 kg
50 kg
Minimum bending radius during installation
80 mm
100 mm
Minimum bending radius installed
65 mm
65 mm
03/12/10 - http://www.nexans.co.uk
Page 181 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2),
OM3 and OM4
•
•
•
•
•
•
•
•
Factory terminated MPO-MPO bre assembly
Easy installation of Pre-Term since assembly can bend in any direction.
Small diameter of cable to reduce data centre space
Polarity in optical channel is easily maintained by its advanced design
Only one type of patch cords and one type of cassettes required
12 bres
Fibre type: Singlemode (OS2), OM3 and OM4
Normal and low loss connectivity
Description
MPO-MPO Pre-Term characteristics
The round cable design facilitates the installation of the MPO-MPO Pre-Term: the
small bending radius of only 30 mm in any direction eliminates the problems of
preferential bending associated with traditional ribbon MPO cables.
Polarity in the optical channel during installation is guaranteed due to a pair ip
bre construction. This is in agreement with standard TIA 568-B-1-7-2006
method C. It allows the continuous use of the standard patch cords eliminating
the need to buy optically straight patch cords. Also polarity is maintained with the
same type of cassette on both sides of the channel without the need to ip the
cassette on one side.
The Pre-Term is available with OM3, OM4 and singlemode bres. The
singlemode bres are according to the specications for G652D and OS2 cables.
Details on the bre specications can be found in the detailed bre datasheets.
The typical value for the insertion loss for a normal loss MPO-MPO connection is
0,3 dB. The limit value is 0,6 dB measured according to standard IEC61300-3-45.
The typical value for the insertion loss for a low loss MPO-MPO connection is 0,2
dB. The limit value is 0,35 dB measured according to standard IEC61300-3-45.
Mechanical characteristics of the Pre-Term are conform to the IEC-60794-20
standard for indoor cables.
The small diameter of 2.5 mm of the cable reduces signicantly the expensive
space required for cabling in a data centre and facilitates the airow.
The MPO-MPO Pre-Term has standard non-pinned (female) connectors. This
matches with the pinned (male) connectors in the MPO modules.
Consistent quality
In order to produce high quality, reliable pre-terminated multi-bre cables, there
are a number of physical characteristics that must be addressed. Therefore, all
LANmark-OF MPO-MPO Pre-Term are fully terminated and tested in a quality
assured factory environment. They are delivered with these test results.
Operating temperature,
range
0 .. 50 °C
Storage temperature,
range
-40 .. 60 °C
Fire retardant
IEC 60332-3
03/12/10 - http://www.nexans.co.uk
Flame retardant
IEC 60332-1
Minimum static operating bending
radius
30 mm
Page 182 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2),
OM3 and OM4
MPO-MPO Pre-Term Benefits
•
•
•
•
•
•
•
•
•
•
•
Short & reliable manufacturing lead-time
Fast installation times
No specialised termination training required
No consumables, termination tool kits
No cable preparation necessary
No cable or connector scrap
No termination errors on site
Delivered fully tested, labelled and documented
Improved end-to-end attenuation
Reduced on-site disruption and installation time
Cost effective solution
Operating temperature,
range
0 .. 50 °C
Storage temperature,
range
-40 .. 60 °C
Fire retardant
IEC 60332-3
03/12/10 - http://www.nexans.co.uk
Flame retardant
IEC 60332-1
Minimum static operating bending
radius
30 mm
Page 183 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2),
Characteristics
OM3 and OM4
Dimensional characteristics
Approximate weight
Outer Diameter
Mechanical characteristics
Maximum pulling force (IEC 60794-1-2-E1)
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Operating temperature, range
Storage temperature, range
Fire retardant
Flame retardant
Minimum static operating bending radius
5.5 kg/km
2.5 mm
400 N
50 N/cm
0 .. 50 °C
-40 .. 60 °C
IEC 60332-3
IEC 60332-1
30 mm
Insertion loss for individual MPO connection
Fibre type
Multimode (OM3 or OM4) Singlemode (OS2 with G652D)
Normal loss connection -Typical loss
0.3 dB
0.3 dB
Normal loss connection - Max loss
0.6 dB
0.6 dB
Low loss connection - Typical loss
0.15 dB
0.15 dB
Low loss connection - Max loss
0.3 dB
0.3 dB
Measured in manufacturing according to standard IEC 61300-3-45
N-number codication: N15A.P12QVXXX
Letter in N-number Description
Variations
A
Fibre type
4: SM (OS2) or 5: OM3, 7: OM4
Q
Performance
Normal (S) or low loss (L)
V
Fanout type
Default (N): No pulling eye and protection tube
XXX
Length between glands 001-300 m
Example: N155.P12LN050: LANmark-OF MPO-MPO Slim Pre-Term with 12 OM3 bres, low loss connectors with a length
of 50 m between the cable glands.
03/12/10 - http://www.nexans.co.uk
Page 184 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Plug&Play Patch Panels
•
•
•
•
Optical patch panels that holds up 4 MPO modules in 1 HU
Sliding patch panels for ease of installation, upgrade and maintenance
High density connectivity: up to 48 SC or 96 LC depending on module type.
Labelling front for port identication and patch cord management within 1 HU
Description
Plug&Play Concept Description
The Nexans' Plug and Play concept is specically designed for installation in data
centres where the high density, integrated patch cord guide and enhanced
installation benets of the patch panel meet the key requirements for
implementation. It allows quick changes with limited down time, easy migration to
other applications and a transition path to 40G.
The Plug&Play system consists of 3 subcomponents: Plug&Play modules, the
MPO-MPO Pre-Term and the Plug&Play patch panel.
The modules provide the transition between the MPO-MPO Pre-Term and the
active devices: the Pre-Term connects to the back of the module and inside the
module the bres are spread out towards the SC/LC connectors at the front.
Modules are available in a wide variety of port counts and connector style.
Plug&Play Patch Panel Characteristics
Standards
International ISO/IEC 11801
The Nexans unique patch panel design allows to hold up to 4 MPO cassettes in
1HU of the distribution rack. Depending on the type of the module a high density
of up to 96 bre connections can be accommodated.
The new patch cord guide sits in front of the modules and allows the patch cords
to be managed within the same 1 HU saving expensive rack space.
The patch cord guide also provides a labelling facility to identify connections.
Additional labelling is provided by printed port numbers on the modules.
The newly developed trays slide for improved access to install new modules and
to x the MPO-MPO Pre-Term easily. The front of the patch panel can be xed in
a ush or recessed position in the rack.
The N439.2MPP is optimised for installation of the trunk MPO-MPO Pre-Term:
the cable glands of the Pre-Term allow a fast and solid xation of the cable.
There is ample space inside the patch panel to organise the exible fan-out of the
MPO-MPO Pre-Term.
The N441.2MPP is optimised for installation of multiple slim Pre-Terms. The slim
Pre-Terms are xed with tie wraps.
Panels are fully painted in black for a professional look and feel.
Blank llers (N441.2MBP) are available as separate accessories for unused
positions to give a nished look.
03/12/10 - http://www.nexans.co.uk
Page 185 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF [email protected] Module
•
•
•
•
•
•
[email protected] module with 12SC, 12 LC or 24 LC connections
Available with LANmark-OF [email protected] connectivity and low loss connectivity grade
Available in LANmark-OF OM4 multimode and LANmark-OF OS2 singlemode
Module can be easily mounted into Nexans' Plug&Play patch panel
High density: 4 modules t into 1U
[email protected] modules are pre-installed and 100 % factory tested
Description
The [email protected] system consists of 3 subcomponents: the MPO modules, the
MPO-MPO Pre-Terms and the Plug&Play patch panel.
The central component is the pre-installed [email protected] module. The MPO
connector at the back of the module connects at once 12 bres of the MPO-MPO
Pre-Term. Inside the module the bres are spread out towards the SC/LC
adaptors at the front.
[email protected] Module Characteristics
Up to 4 [email protected] modules can be installed quickly into the Plug&Play patch
panel with push rivets. With these 4 modules a medium density of 48 SC or 48 LC
connections within 1U can be achieved. With the 24 LC high density module a
maximum of 96 LC connections within 1U is also possible.
Standards
International ISO/IEC 11801
The insertion loss for the LANmark-OF [email protected] module is 0,9 dB measured
according to standard IEC 61300-3-45.
The insertion loss for the LANmark-OF [email protected] low loss module is 0,6 dB
measured according to standard IEC 61300-3-45.
The modules are available with OM4 bres for multimode and are backwards
compatible with OM3 bres. The singlemode module has G652D bres for OS2
compatibility.
The wiring inside the module is straight. This allows to maintain polarity in the
MPO-link together with the pair-wise bre ip inside the MPO-MPO Pre-Term
according to method C from standard TIA 568-B-1-7-2007.
Since all connectivity is factory installed and factory tested installation times are
short for a quick deployment or for frequent changes.
The [email protected] module has standard pinned (male) connectors. This matches
perfectly with the non-pinned (female) connectors of the MPO-MPO Pre-Term.
03/12/10 - http://www.nexans.co.uk
Page 186 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF [email protected] Module
N-numbers for Plug&Play Modules
N441.2M24LC4 LANmark-OF Plug&Play Module 24 LC OM4
OM3/OM4
N441.2M12LC4 LANmark-OF Plug&Play Module 12 LC OM4
N441.2M12SC4 LANmark-OF Plug&Play Module 12 SC OM4
MPO Module
N441.2M24LC0 LANmark-OF Plug&Play Module 24 LC Singlemode
SM OS2
N441.2M12LC0 LANmark-OF Plug&Play Module 12 LC Singlemode
N441.2M12SC0 LANmark-OF Plug&Play Module 12 SC Singlemode
OM3/OM4
MPO Low Loss Module
SM OS2
N441.2L24LC4
LANmark-OF Plug&Play Low Loss Module 24 LC OM4
N441.2L12LC4
LANmark-OF Plug&Play Low Loss Module 12 LC OM4
N441.2L12SC4
LANmark-OF Plug&Play Low Loss Module 12 SC OM4
N441.2L24LC0
LANmark-OF Plug&Play Low Loss Module 24 LC Singlemode
N441.2L12LC0
LANmark-OF Plug&Play Low Loss Module 12 LC Singlemode
N441.2L12SC0
LANmark-OF Plug&Play Low Loss Module 12 SC Singlemode
03/12/10 - http://www.nexans.co.uk
Page 187 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre Patch Panels
LANmark-OF offers cutting edge hardware products including patch panels, zone
distribution boxes and outlets.
Each product has been thoroughly developed to ensure best system offering
while meeting stringent international standards.
Modular concept
The fully modular design allows mixing of different Snap-in adaptor types : LC,
MT-RJ and SC. Benets: up to 24 bres for the Zone Distribution Box and 48 for
the Patch Panel. Both are compatible for loose tube and tight buffer cables.
03/12/10 - http://www.nexans.co.uk
Page 188 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Sliding Patch Panels
•
•
•
•
•
Empty OF patch panels with sliding mechanism.
Suitable for direct termination or splicing.
Available in two versions 24 ST or modular Duplex or simplex SC, LC, or MT-RJ snap-ins.
Inner sliding to respect bending radius of patch cord.
LANmark look.
Description
Application
Accepting the range of ST couplers or LANmark-OF snap-ins, these patch panels
with sliding mechanism facilitate front side installation.
Compatibility
Suitable for tight buffer cables (direct termination) , Loose tube cables using
Splice Cassette / pigtailed terminations. Accepts pre-terminated cable
assemblies.
Installation
•
•
•
•
19" width. 1U
Accommodates 24 ST or 24 LANmark-OF snap-ins (or 12DSC).
2 positions : ush or recessed with respect of cable bend radius.
Comes with marking strips to number and categorise ports.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 189 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Sliding Patch Panels
Product List
Nexans ref.
N441.204
Nouveauté
N441.203
Nouveauté
N441.201
=Make to order,
=Make to stock
Name
LANmark-OF Patch Panel Snap-In Sliding Black
LANmark-OF Patch Panel Snap-In Sliding White
LANmark-OF Patch Panel 24 ST Sliding White
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 190 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Sliding Preloaded Patch Panels
•
•
•
•
•
•
Preloaded patch panels with adaptors for fast installation in data centres
High density connectivity: up to 48 SC or 96 LC.
Sliding and tilting patch panel for ease of installation, upgrade and maintenance
Optimised for installation of Pre-Term with a cable gland and bre management features
Improved splice cassettes with lifting functionality for improved ease of installation and inspection
Labelling facility for port identication and patch cord management within 1 U
Description
The new pre-loaded patch panel is specically designed for installation in data
centres where the high density, integrated patch cord guide and enhanced
installation benets of the patch panel meet the key requirements for
implementation.
The patch panels are pre-loaded with SC or LC adaptors and are available in
medium and high density versions. The medium density patch panel provides 24
SC or 48 LC connections, while the high density version has 48 SC or 96 LC
connections. Singlemode and multimode versions are available.
The new patch cord guide sits in front of the adaptors and allows the patch cords
to be managed within the same 1 U saving expensive rack space.
The patch cord guide also provides a labelling facility to identify connections.
Additional labelling is provided by printed port numbers on the adaptor plate.
The newly developed chassis of the patch panel can be removed from the rack
completely to ease installation of direct terminated or spliced bre and faster
installation of pre-terminated cables. The tray tilts and slides for improved access
to the installed bres for inspection.
Standards
International ISO/IEC 11801
The pre-loaded patch panel has extended cable management with multiple
entries to provide maximum exibility. It accommodates both cable glands and tie
wraps for strain relief of the cables. The cable gland sizes are 20 mm (8x) and 25
mm (2x).
For improved bre management the bres can be arranged in 4 separate loops
for added exibility and organisation. The support bases and the rings for these 4
loops are included.
The patch panel chassis has multiple, specially designed, slots at the rear to x
the cable glands of Nexans’ pre-terminated cables. There is ample space inside
the patch panel to organise the exible fan-out of the pre-terminated cables.
Up to 4 splice cassettes (N890.090 and N890.091) can be installed inside the tray
of the patch panel. Only one cover (N890.093) is required to close the splice
cassettes at the top. The bottom splice cassette is xed with screws to the
chassis of the patch panel. Splice cassettes are xed with hinges to the cassette
below and with such an installation the splice cassettes can be lifted and tilted for
improved access to the splices inside the patch panel. This facilitates the
inspection of the splices after installation.
Each splice cassette for heat shrink protectors (N890.090) can accommodate 12
splices allowing a maximum of 48 splices for the complete patch panel.
The splice cassette for aluminium protectors (N890.091) has a maximum of 24
splices resulting in a maximum of 96 splices per patch panel. N890.091 can only
be used with maxistrip pigtails and cables with 250 um bres.
Splice cassettes are not included in the patch panel.
The front adaptor plate can be xed in a ush or recessed position in the rack
using the adjustable side brackets. When the panel is installed recessed the
distance between the rack vertical and the rear of the panel is 288 mm. The front
cord management projection is 67 mm. When the panel is installed ush the
distance between the rack vertical and the rear of the panel is 248 mm. The front
cord management projection is 107 mm.
03/12/10 - http://www.nexans.co.uk
Page 191 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Sliding Preloaded Patch Panels
Panels are fully painted in black for a professional look and feel.
03/12/10 - http://www.nexans.co.uk
Page 192 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Sliding Preloaded Patch Panels
Available versions and N-numbers
N-number
Description
SC or LC # connections SM or MM
N439.2B48LCMM LANmark-OF Preloaded Patch Panel 48 LC Multimode Sliding Black
LC
48
N439.2B48LCSM
LC
48
SM
LC
96
MM
LANmark-OF Preloaded Patch Panel 48 LC Singlemode Sliding Black
N439.2B96LCMM LANmark-OF Preloaded Patch Panel 96 LC Multimode Sliding Black
N439.2B96LCSM
LANmark-OF Preloaded Patch Panel 96 LC Singlemode Sliding Black
MM
LC
96
SM
N439.2B24SCMM LANmark-OF Preloaded Patch Panel 24 SC Multimode Sliding Black
SC
24
MM
N439.2B24SCSM LANmark-OF Preloaded Patch Panel 24 SC Singlemode Sliding Black
SC
24
SM
N439.2B48SCMM LANmark-OF Preloaded Patch Panel 48 SC Multimode Sliding Black
SC
48
MM
N439.2B48SCSM LANmark-OF Preloaded Patch Panel 48 SC Singlemode Sliding Black
SC
48
SM
03/12/10 - http://www.nexans.co.uk
Page 193 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-OF Fixed Patch Panel
•
•
•
•
•
Empty OF patch panel without sliding mechanism.
Suitable for direct termination or splicing.
Can be used as splitter box.
Available in two versions 24ST and 24 SC.
Three positions faceplate for patch cord bending radius.
Description
Application
Nexans Essential 1U Optical Fibre Patch Panel has been designed to support :
• up to 24 ST ports or
• up to 12 Dual SC ports.
It combines a cost effective design with high port density. It is suitable for tight
buffer cables (direct termination) or loose tube cables using splice tray
(N890.001).
It also can be used as a splitter(*)
Features
•
•
•
•
19" width
Two versions ST and SC
Blind face plates are available.
3 positions :
-ushed
-15 mm recessed
Standards
-30 mm recessed
International ISO/IEC 11801
• Easy identication : couplers are numbered on the face plate.
• Cable entrance is possible through a cable gland (PG16) or through a
rectangular opening (Using tie wraps).
• Cage-nuts as well as bre holders are included.
(*) splitter allows to split multitube cable to at most 6 Nexans E-ssential OF Patch
Panels.
For use as splitter, you need:
-Splitter tube (N890.044)
-Cable gland for splitter (N890.043)
-Blind plate (N441.132)
03/12/10 - http://www.nexans.co.uk
Page 194 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Essential-OF Fixed Patch Panel
Characteristics
Dimensional characteristics
Heightunit
Width
Depth
Usage characteristics
Component function
Product List
Nexans ref.
N441.122
N441.121
1U
19 in
233 mm
Patch panel
Name
Essential-OF Patch Panel 24 SC White
Essential-OF Patch Panel 24 ST White
Connector type
SC
ST
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 195 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Outlets
03/12/10 - http://www.nexans.co.uk
Page 196 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Zone Distribution box
• Empty ZD box optical ber
• Suitable for direct termination or splicing.
Description
Application
• Designed for the installation of zone wiring, bre to the ofce and to the desk
Compatibility
Suitable for tight buffer cable (direct termination) or loose tube using splice tray
Compatible with all LANmark-OF accessories
Installation
The OF zone distribution box is easy to install in the ceiling, false oor or on the
wall with four xation points in the bottom plate.
To enter the cable there is a pre-perforated hole for a cable gland PG 16
foreseen, at the backside.
There is a xation point for the Nexans splice tray.
Standards
International ISO/IEC 11801
Printed numbering system on the cover
03/12/10 - http://www.nexans.co.uk
Page 197 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Zone Distribution box
Characteristics
Dimensional characteristics
Depth
Height
Width
Usage characteristics
Field of application
Packaging
200 mm
40 mm
230 mm
Indoor
Box
Characteristics ZD box
Connector type
Product List
Nexans ref.
N521.630
LC
Name
LANmark-OF modular Zone distribution box empty
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 198 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Structural Hardware
•
•
•
•
•
For all 45x45mm ttings
Fits Surface Mount Boxes, Cover plates and Ducts
Outlets include labeling and shutters
Suitable for all snap-in adaptors.
Easy click-in mechanism.
Description
Application
This range of outlets is suitable for any environment: ducts, cover plates and
surface mount boxes (including 45 ttings). The range features Snap-in adaptors
for fast and easy installation.
For the specic information on the Snap-in adaptors , refer to the corresponding
datasheets.
Guarantees
• All plastic material is UL 94V0
Installation
These modular outlets t into a complete range of international 45x45 covering
plates and surface mount boxes.
For easy management and identication, the outlets are include an integrated
outlet labelling system using transparent windows.
The Snap-in connectors are inserted into the modular outlet by a simple click-in
mechanism.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 199 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Structural Hardware
Product List
Nexans ref.
N420.035
Nouveauté
Name
Modular OF Splicing Outlet 45X45 for 2 Snap-in adaptors
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 200 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Patch Cords
03/12/10 - http://www.nexans.co.uk
Page 201 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Patch Cords
Description
Application
Nexans LANmark-OF optical bre patchcords have been designed for
applications where a high level of optical features is required.
• Suitable for use in cabinets to connect patch panels/active equipments to active
equipments.
• Suitable for use in the work area to connect the work station to the wall outlet
(Fibre To The Desk).
Applications support :
•
•
•
•
•
•
•
•
•
•
•
•
Fast Ethernet 100 base FX
1Gbase SX
1Gbase LX
10Gbase SR
10Gbase LW
10Gbase LX4
10Gbase LR
10Gbase LRM
Fibre Channel Serial 1G
Fibre Channel Serial 2G
Fibre Channel Serial 4G
Fibre Channel Serial 10G
Standards
International ISO/IEC 11801
Performance
Nexans LANmark-OF patchcords are available in all standardised optical bre
classes, multimode and single mode.The MM62.5 version is designed for use in
an OM1 compliant system, the MM50 version for OM2 systems and the MM50
OM3 version for OM3 systems. The singlemode version is OS2 compliant. The
multimode versions can be used in laser optimised systems using the LANmarkOF xt cables.
Design
Nexans LANmark-OF patchcords designed according the "Cross-Over" wiring
principle to improve eld installation (A1-B2, B1-A2).
Guarantees
Nexans LANmark-OF patchcords are guaranteed to support LED based
applications as well as Laser based applications.They are covered by Nexans
warranty as described in the General Terms and Conditions.
Characteristics
Construction characteristics
Armour type
Outer sheath
Operating temperature, range
-10 .. 50 °C
Aramid yarn
LSZH-FR
Fire retardant
IEC 60332-3 Cat.C
03/12/10 - http://www.nexans.co.uk
Minimum static operating bending radius
40 mm
Page 202 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Patch Cords
Mechanical characteristics
Maximum pulling force by laying
Crush resistance (IEC 60794-1-E3)
Usage characteristics
Operating temperature, range
Fire retardant
Minimum static operating bending radius
Product List
Nexans ref.
N123.2LLO2
N123.2LLO5
N123.2CLO2
N123.2CLO5
N123.2LTO2
N123.2LTO5
N123.2CCO2
N123.2CCO5
N123.2CTO2
N123.2CTO5
N123.2TTO2
N123.2TTO5
N123.2MLO2
N123.2MLO5
N123.2MCO2
N123.2MCO5
N123.2MTO2
0.2 kN
250 N/cm
-10 .. 50 °C
IEC 60332-3 Cat.C
40 mm
Name
Length
(m)
LANmark-OF Patch cord Multimode 50/125 2LC 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2LC 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 2LC 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2LC 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 2LC 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2LC 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 2SC 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2SC 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 2SC 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2SC 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 2ST 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 2ST 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2ST LSZH Orange 2m
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
=Make to order,
Fiber optic type
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
= Make to order,
Operating temperature, range
-10 .. 50 °C
Fire retardant
IEC 60332-3 Cat.C
03/12/10 - http://www.nexans.co.uk
=Make to stock
Connector
type
LC
LC
SC-LC
SC-LC
LC
LC
SC
SC
SC
SC
ST
ST
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
= Make to stock
Minimum static operating bending radius
40 mm
Page 203 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Patch Cords
Nexans ref.
N123.2MTO5
N123.2MMO2
N123.2MMO5
N123.5LLO2
N123.5LLO5
N123.5CLO2
N123.5CLO5
N123.5LTO2
N123.5LTO5
N123.5CCO2
N123.5CCO5
N123.5CTO2
N123.5CTO5
N123.5TTO2
N123.5TTO5
N123.5MLO2
N123.5MLO5
N123.5MCO2
N123.5MCO5
N123.5MTO2
N123.5MTO5
N123.5MMO2
N123.5MMO5
Name
Length
(m)
LANmark-OF Patch cord Multimode 50/125 MT-RJ 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 MT-RJ MT-RJ LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 MT-RJ MT-RJ LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2LC - 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2SC - 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2SC - 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2SC - 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2SC - 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3
2ST - 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3
2ST - 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - MT-RJ LSZH Orange 2m
LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - MT-RJ LSZH Orange 5m
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
Fiber optic type
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM2 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
OM3 50/125 Extended
Distance
= Make to order,
Operating temperature, range
-10 .. 50 °C
Fire retardant
IEC 60332-3 Cat.C
03/12/10 - http://www.nexans.co.uk
Connector
type
MT-RJ
MT-RJ
MT-RJ
LC
LC
SC-LC
SC-LC
LC
LC
SC
SC
SC
SC
ST
ST
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
= Make to stock
Minimum static operating bending radius
40 mm
Page 204 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Patch Cords
Nexans ref.
N123.0LLO2
N123.0LLO5
N123.0CLO2
N123.0CLO5
N123.0LTO2
N123.0LTO5
N123.0CCO2
N123.0CCO5
N123.0CTO2
N123.0CTO5
N123.0TTO2
N123.0TTO5
N123.0MLO2
N123.0MLO5
N123.0MCO2
N123.0MCO5
N123.0MTO2
N123.0MTO5
N123.0MMO2
N123.0MMO5
N123.4LLY2
N123.4LLY5
N123.4CLY2
Name
Length
(m)
LANmark-OF Patch cord Multimode 62,5/125 2LC 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2LC 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 2LC 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2LC 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 2LC 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2LC 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 2SC 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2SC 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 2SC 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2SC 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 2ST 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 2ST 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2LC LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2LC LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2SC LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2SC LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2ST LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- 2ST LSZH Orange 5m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- MT-RJ LSZH Orange 2m
LANmark-OF Patch cord Multimode 62,5/125 MT-RJ
- MT-RJ LSZH Orange 5m
LANmark-OF Patch cord Singlemode OS2 2LC - 2LC
LSZH Yellow 2m
LANmark-OF Patch cord Singlemode OS2 2LC - 2LC
LSZH Yellow 5m
LANmark-OF Patch cord Singlemode OS2 2LC 2SC LSZH Yellow 2m
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
2
5
Fiber optic type
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
OM1 62.5/125
Extended Distance
Fire retardant
IEC 60332-3 Cat.C
03/12/10 - http://www.nexans.co.uk
LC
LC
SC-LC
SC-LC
LC
LC
SC
SC
SC
SC
ST
ST
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
MT-RJ
2
SM (G.652D)
LC
5
SM (G.652D)
LC
2
SM (G.652D)
SC-LC
= Make to order,
Operating temperature, range
-10 .. 50 °C
Connector
type
= Make to stock
Minimum static operating bending radius
40 mm
Page 205 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Patch Cords
Nexans ref.
N123.4CLY5
N123.4LTY2
N123.4LTY5
N123.4CCY2
N123.4CCY5
N123.4CTY2
N123.4CTY5
N123.4TTY2
N123.4TTY5
N123.7LLO2
Name
Length
(m)
Fiber optic type
Connector
type
5
SM (G.652D)
SC-LC
2
SM (G.652D)
LC
5
SM (G.652D)
LC
2
SM (G.652D)
SC
5
SM (G.652D)
SC
2
SM (G.652D)
SC
5
SM (G.652D)
SC
2
SM (G.652D)
ST
5
SM (G.652D)
ST
2
OM4 50/125
LC
LANmark-OF Patch cord Singlemode OS2 2LC 2SC LSZH Yellow 5m
LANmark-OF Patch cord Singlemode OS2 2LC - 2ST
LSZH Yellow 2m
LANmark-OF Patch cord Singlemode OS2 2LC - 2ST
LSZH Yellow 5m
LANmark-OF Patch cord Singlemode OS2 2SC 2SC LSZH Yellow 2m
LANmark-OF Patch cord Singlemode OS2 2SC 2SC LSZH Yellow 5m
LANmark-OF Patch cord Singlemode OS2 2SC 2ST LSZH Yellow 2m
LANmark-OF Patch cord Singlemode OS2 2SC 2ST LSZH Yellow 5m
LANmark-OF Patch cord Singlemode OS2 2ST - 2ST
LSZH Yellow 2m
LANmark-OF Patch cord Singlemode OS2 2ST - 2ST
LSZH Yellow 5m
LANmark-OF Patchcord Multimode 50/125 OM4 2LC
- 2LC LSZH Orange 2m
= Make to order,
= Make to stock
Optical Performance Patch Cords
Fibre type
Connector Polishing Insertion loss max. Return loss min.
Multimode
ST-SC-LC
PC
0,3 dB
> 30 dB
Multimode
MT-RJ
PC
0,3 dB
NA
Singlemode ST-SC-LC
PC
0.3 dB
> 40 dB
Singlemode SC-LC
APC
0,3 dB
> 55 dB
Singlemode MT-RJ
NA
NA
NA
Operating temperature, range
-10 .. 50 °C
Fire retardant
IEC 60332-3 Cat.C
03/12/10 - http://www.nexans.co.uk
Minimum static operating bending radius
40 mm
Page 206 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Pigtails & Splicing Materials
03/12/10 - http://www.nexans.co.uk
Page 207 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Aluminium Protectors
Preloaded Sliding Panel
Description
Family Characteristics
• Family of patch panel accessories for termination of a cable with fusion splicing
techniques.
• Provides management for cable and pigtails within the bre patch panel.
• The cassette protects the fusion splices and holds them in position.
• The splice cassette can retain up to 24 fusion splices.
• Four trays can be stacked inside the patch panels resulting in a maximum
capacity of 96 fusion splices in a patch panel.
• Splice cassettes are xed to each other at the back of the cassettes with the
provided hinges. This feature facilitates the inspection after installation since
the cassettes can be lifted and tilted.
• The larger cassettes facilitates 2 rings of routing: an inner ring for the bres of
the pigtails and an outer ring for the bres of the cable.
• Splicing with Aluminium protectors can be used for loose tube cables, i.e. bres
with a 250 um coating. Aluminium protectors can not be used with tight buffer
cables, i.e. bres with a 900 um coating.
• Splicing with Aluminium protectors can be used for maxistrip pigtails.
• LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of
loose tube cable into different splice cassettes.
• These splice cassettes can be installed in the LANmark-OF and LANsense-OF
sliding preloaded patch panels (N439.2B* and N883.2B*).
03/12/10 - http://www.nexans.co.uk
Standards
International ISO11801:2002/
A1:2008
Page 208 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Aluminium Protectors
N890.091: LANmark-OF Splice Cassette 24 Aluminium Protection Sliding
Preloaded Panel
Preloaded
Sliding Panel
•
•
•
•
Splice Cassette for management of splices with Aluminium protectors.
Provides support for 2*12 splices with Aluminium protectors.
Designed for use with loose tube cables (250 um coated bres).
Designed for use with maxistrip pigtails.
N890.003: LANmark-OF Fusion Splice Aluminium Protectors
•
•
•
•
•
•
LANmark OF- accessories to complete the splicing system with Aluminium protectors
150 pieces per bag
Lenght: 30 mm
Compatible with loose tube cables (250 um coated bres)
Compatible with maxistrip pigtails
Designed for Nexans’ splice cassette for 24 Aluminium fusion splice protectors (N890.091)
N890.092: LANmark-OF Cover Splice Cassette Sliding Pre-loaded Panel
• LANmark-OF accessories to complete splice cassette system.
• LANmark-OF splice cassette cover compatible with N890.090 and N890.091.
• When the splice cassettes are stacked only the top splice cassette requires a cover.
03/12/10 - http://www.nexans.co.uk
Page 209 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Aluminium Protectors
Preloaded Sliding Panel
N890.004: Tool for Aluminium Fusion Splice Protectors
• A crimp tool for easy installation of the Aluminium fusion splice protectors.
• Compatible with Nexans Aluminium fusion splice protector (N890.003).
03/12/10 - http://www.nexans.co.uk
Page 210 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Aluminium Protectors
Snap-In Panel
Description
Family Characteristics
• Family of patch panel accessories for termination of a cable with fusion splicing
techniques.
• Provides management for cable and pigtails within the bre patch panel.
• The cassette protects the fusion splices and holds them in position.
• The splice cassette can retain up to 24 fusion splices.
• Four trays can be stacked inside the patch panels resulting in a maximum
capacity of 96 fusion splices in a patch panel.
• Splicing with Aluminium protectors can be used for loose tube cables, i.e. bres
with a 250 um coating. Aluminium protectors can not be used with tight buffer
cables, i.e. bres with a 900 um coating.
• Splicing with Aluminium protectors can be used for maxistrip pigtails.
• LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of
loose tube cable into different splice cassettes.
• These splice cassettes can be installed in the LANmark-OF Snap-In Patch
Panel (N441.203 and N441.204) and the LANmark-OF Zone Distribution Box
(N521.630).
03/12/10 - http://www.nexans.co.uk
Standards
International ISO11801:2002/
A1:2008
Page 211 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Aluminium Protectors
N890.096: LANmark-OF Splice Cassette 24 Aluminum Protectors Snap-In Panel
Snap-In Panel
•
•
•
•
Splice Cassette for management of splices with Aluminium protectors.
Provides support for 2*12 splices with Aluminium protectors.
Designed for use with loose tube cables (250 um coated bres).
Designed for use with maxistrip pigtails.
N890.003: LANmark-OF Fusion Splice Aluminium Protectors
•
•
•
•
•
•
LANmark OF- accessories to complete the splicing system with Aluminium protectors
150 pieces per bag
Lenght: 30 mm
Compatible with loose tube cables (250 um coated bres)
Compatible with maxistrip pigtails
Designed for Nexans’ splice cassette for 24 Aluminium fusion splice protectors (N890.096)
N890.097: Cover for Splice Cassette Snap-In Panel
• LANmark-OF accessories to complete splice cassette system.
• LANmark-OF splice cassette cover compatible with N890.095 and N890.096.
03/12/10 - http://www.nexans.co.uk
Page 212 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
•
LANmark-OF Splicing Accessories with Aluminium Protectors
When the splice cassettes are stacked only the top splice cassette requires a cover.
Snap-In Panel
N890.004: Tool for Aluminium Fusion Splice Protectors
• A crimp tool for easy installation of the Aluminium fusion splice protectors.
• Compatible with Nexans Aluminium fusion splice protector (N890.003).
03/12/10 - http://www.nexans.co.uk
Page 213 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
Preloaded Sliding Panel
Description
Family Characteristics
• Family of patch panel accessories for termination of a cable when using fusion
splicing techniques.
• The cassette protects the fusion splices and holds them in position.
• The splice cassette can retain up to 12 fusion splices.
• Four trays can be stacked inside the patch panels resulting in a maximum
capacity of 48 fusion splices in a patch panel.
• Splice cassettes are xed to each other at the back of the cassettes with the
provided hinges. This feature facilitates the inspection after installation since
the cassettes can be lifted and tilted.
• The large cassettes facilitates 2 rings of routing: an inner ring for the bres of
the pigtails and an outer ring for the bres of the cable.
• Splicing with heat shrink protectors can be used for both tight buffer and loose
tube cables, i.e. heat shrink protectors are compatible with both 250 and 900
um coated bres.
• Splicing with heat shrink protectors can be used for both maxistrip and tight
buffer pigtails.
• LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of
loose tube cable into different splice cassettes.
• These splice cassettes can be installed in the LANmark-OF and LANsense-OF
sliding preloaded patch panels (N439.2B* and N883.2B*).
03/12/10 - http://www.nexans.co.uk
Standards
International ISO11801:2002/
A1:2008
Page 214 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
N890.090: LANmark-OF Splice Cassette 12 Heat Shrink Protection Sliding
Preloaded Panel
Preloaded
Sliding Panel
•
•
•
•
Splice cassette for management of splices with heat shrink protectors.
Provides support for 2*6 heat shrink splice protectors.
Designed for use with both loose tube and tight buffer cables, i.e. 250 and 900 um coated bres.
Designed for use with both maxistrip and tight buffer pigtails.
N890.021: LANmark-OF Fusion Splice Heat Shrink protectors (45mm)
•
•
•
•
•
•
LANmark OF-accessories to complete the splicing system with heat shrink protectors
100 pieces per bag
Lenght: 45mm
Compatible with tight buffer or loose tube cables, i.e. 250 and 900 um coated bres.
Compatible with tight buffer and maxistrip pigtails
Designed for Nexans’ splice cassette for 12 heat shrink fusion splice protectors (N890.090)
N890.092: LANmark-OF Cover Splice Cassette Sliding Preloaded Panel
• LANmark-OF accessories to complete splice cassette system.
• LANmark-OF splice cassette cover compatible with N890.091 and N890.092.
• When the splice cassettes are stacked only the top splice cassette requires a cover.
03/12/10 - http://www.nexans.co.uk
Page 215 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
Preloaded Sliding Panel
03/12/10 - http://www.nexans.co.uk
Page 216 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
Snap-In Patch Panel
Description
Family Characteristics
• Family of patch panel accessories for termination of a cable when using fusion
splicing techniques.
• The cassette protects the fusion splices and holds them in position.
• The splice cassette can retain up to 12 fusion splices.
• Four trays can be stacked inside the patch panels resulting in a maximum
capacity of 48 fusion splices in a patch panel.
• Splicing with heat shrink protectors can be used for both tight buffer and loose
tube cables, i.e. heat shrink protectors are compatible with both 250 and 900
um coated bres.
• Splicing with heat shrink protectors can be used for both maxistrip and tight
buffer pigtails.
• LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of
loose tube cable into different splice cassettes.
• These splice cassettes can be installed in the LANmark-OF Snap-In Patch
Panel (N441.203 and N441.204) and the LANmark-OF Zone Distribution Box
(N521.630).
03/12/10 - http://www.nexans.co.uk
Standards
International ISO11801:2002/
A1:2008
Page 217 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
N890.095: LANmark-OF Splice Cassette 12 Heat Shrink Protectors Snap-In Panel
Snap-In Patch Panel
•
•
•
•
Splice cassette for management of splices with heat shrink protectors.
Provides support for 2*6 heat shrink splice protectors.
Designed for use with both loose tube and tight buffer cables, i.e. 250 and 900 um coated bres.
Designed for use with both maxistrip and tight buffer pigtails.
N890.021: LANmark-OF Fusion Splice Heat Shrink protectors (45mm)
•
•
•
•
•
•
Lanmark OF-accessories to complete the splicing system with heat shrink protectors
100 pieces per bag
Lenght: 45mm
Compatible with tight buffer or loose tube cables, i.e. 250 and 900 um coated bres.
Compatible with tight buffer and maxistrip pigtails
Designed for Nexans’ splice cassette for 12 heat shrink fusion splice protectors (N890.095)
N890.097: Cover for Splice Cassette Snap-In Panel
• LANmark-OF accessories to complete splice cassette system.
03/12/10 - http://www.nexans.co.uk
Page 218 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Splicing Accessories with Heatshrink Protectors
LANmark-OF splice cassette cover compatible with N890.095 and N890.096.
Snap-In Patch Panel
•
• When the splice cassettes are stacked only the top splice cassette requires a cover.
03/12/10 - http://www.nexans.co.uk
Page 219 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Splice Materials
Description
A range of materials and accessories for splicing
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 220 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Splice Materials
Product List
Nexans ref.
N890.145
N890.024
N890.023
N890.044
=Make to order,
=Make to stock
Name
LANmark-OF Bend Limiting Tube
LANmark-OF Fusion Splice Heat Shrink Protection (65mm)
Splice Holder
Splitter tube
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 221 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Pigtails Maxistrip
•
•
•
•
•
Maxistrip pigtail for ease of splicing and high density
Insertion loss per connection: 0.3 dB maximum
Factory terminated bre assembly
100 % factory tested
Compatible with LANmark-OF splice cassette with heat shrink or Aluminium protection.
Description
Pigtail family characteristics
•
•
•
•
•
Fibre assembly to terminate cable with fusion splicing
Available with ST, SC, LC and MTRJ connectors
Suitable for use in patch panels using splice cassettes.
The pigtails can be stripped in one action over a long distance of up to 1m.
Insertion loss: typical value is 0.1 dB, maximum value is 0.3 dB.
Fibre types
• Nexans LANmark-OF pigtails are available in all standardised optical bre
classes, multimode and singlemode.
• The MM50 version is designed to be used in a OM3 or a OM3xt compliant
system and is backwards compliant with OM2 and OM2xt systems. The outher
sheath for this type of pigtail is aqua.
• The MM62.5 version is designed for use in OM1 or OM1xt compliant systems.
These pigtails are orange.
• The singlemode version is OS2 compliant with G652d bre inside. These
pigtails are yellow.
• The multimode versions can be used in laser optimised systems using the
LANmark-OF xt cables.
Standards
International ISO/IEC 11801
Compatibility and installation practices
• Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.095)
with heat shrink protections (N890.021).
• Maxistrip pigtails are compatible with splice cassettes (N890.096) with
Aluminium protections (N890.021).
• Maxistrip pigtails are recommended to be used with loose tube cables, i.e. with
250 um bres. When using tight buffer cables (900 um bres) additional stress
on the maxistrip pigtails should be limited as much as possible
• For proper alignment in the fusion splice tool the pigtail is xed on the 250 um
coating after stripping the 900 um coating. Fixing the pigtail on the 900 um
coating will lead to improper alignment.
• In addition the pigtail needs to be stripped till the cladding around the splice
area before insertion in the splice tool.
Guarantuees
Nexans LANmark-OF pigtails are covered by Nexans warranty as described in
the General Terms and Conditions
03/12/10 - http://www.nexans.co.uk
Page 222 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Pigtails Maxistrip
Optical performance pigtails
Fibre type
Connector Polishing Insertion loss max. Return loss min.
Multimode
ST-SC-LC
PC
0,3 dB
> 30 dB
Multimode
MT-RJ
PC
0,3 dB
NA
Singlemode ST-SC-LC
PC
0.3 dB
> 40 dB
Singlemode SC-LC
APC
0,3 dB
> 55 dB
Singlemode MT-RJ
NA
NA
NA
Pigtails maxistrip: available products
Fibre type Connector N-number
SM
SM APC
ST
N123.4MTY LANmark-OF Pigtail ST Singlemode Maxistrip LSZH 9/125 1m Yellow
SC
N123.4MCY LANmark-OF Pigtail SC Singlemode Maxistrip LSZH 9/125 1m Yellow
LC
N123.4MLY
SC
N120.4MDY LANmark-OF Pigtail SC SM APC Maxistrip LSZH 9/125 1m Yellow
LC
N120.4MPY LANmark-OF Pigtail LC SM APC Maxistrip LSZH 9/125 1m Yellow
MTRJ
OM1
N123.0MMO LANmark-OF Pigtail MTRJ OM1 Maxistrip LSZH 62.5/125 1m Orange
ST
N123.0MTO LANmark-OF Pigtail ST OM1 Maxistrip LSZH 62.5/125 1m Orange
N123.0MCO LANmark-OF Pigtail SC OM1 Maxistrip LSZH 62.5/125 1m Orange
LC
N123.0MLO LANmark-OF Pigtail LC OM1 Maxistrip LSZH 62.5/125 1m Orange
N123.5MMA LANmark-OF Pigtail MTRJ OM2/OM3 Maxistrip LSZH 50/125 1m Aqua
ST
N123.5MTA LANmark-OF Pigtail ST OM2/OM3 Maxistrip LSZH 50/125 1m Aqua
SC
N123.5MCA LANmark-OF Pigtail SC OM2/OM3 Maxistrip LSZH 50/125 1m Aqua
LC
N123.5MLA LANmark-OF Pigtail LC OM2/OM3 Maxistrip LSZH 50/125 1m Aqua
MTRJ
OM4
LANmark-OF Pigtail LC Singlemode Maxistrip LSZH 9/125 1m Yellow
SC
MTRJ
OM3
Description
N123.7MMA LANmark-OF Pigtail MTRJ OM4 Maxistrip LSZH 50/125 1m Aqua
ST
N120.7MTA LANmark-OF Pigtail ST OM4 Maxistrip LSZH 50/125 1m Aqua
SC
N120.7MCA LANmark-OF Pigtail SC OM4 Maxistrip LSZH 50/125 1m Aqua
LC
N120.7MLA LANmark-OF Pigtail LC OM4 Maxistrip LSZH 50/125 1m Aqua
03/12/10 - http://www.nexans.co.uk
Page 223 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Pigtails Tight Buffer
•
•
•
•
•
Tight buffer pigtail for ease of splicing
Insertion loss per connection: 0.3 dB maximum
Factory terminated bre assembly
100 % factory tested
Compatible with LANmark-OF splice cassette with heat shrink protection.
Description
Pigtail family characteristics
•
•
•
•
•
Fibre assembly to terminate cable with fusion splicing
Available with ST, SC, LC and MTRJ connectors
Suitable for use in patch panels using splice cassettes.
The pigtails can be stripped in one action over a distance of 1-2 cm.
Insertion loss: typical value is 0.1 dB, maximum value is 0.3 dB.
Fibre types
• Nexans LANmark-OF pigtails are available in all standardised optical bre
classes, multimode and singlemode.
• The MM50 version is designed to be used in a OM3 or a OM3xt compliant
system and is backwards compliant with OM2 and OM2xt systems. The outher
sheath for this type of pigtail is aqua.
• The MM62.5 version is designed for use in OM1 or OM1xt compliant systems.
These pigtails are orange.
• The singlemode version is OS2 compliant with G652d bre inside. These
pigtails are yellow.
• The multimode versions can be used in laser optimised systems using the
LANmark-OF xt cables.
Standards
International ISO/IEC 11801
Compatibility and installation practices
• Tight buffer pigtails are compatible with heat shrink splice cassettes (N890.020)
with heat shrink protections (N890.021).
• Tight buffer pigtails are recommended to be used with tight buffer cables, i.e.
with 900 um bres. When using loose tube cables (250 um bres) additional
stress on the loose tube bres should be limited as much as possible
• Around the splice area the pigtail needs to be stripped till the cladding before
insertion in the splice tool.
• For proper alignment in the fusion splice tool the pigtail is xed on the 900 um
outer sheath. There is no need to strip the outer sheath of the pigtail on the
place for xation for getting a proper xation.
Guarantuees
Nexans LANmark-OF pigtails are covered by Nexans warranty as described in
the General Terms and Conditions
03/12/10 - http://www.nexans.co.uk
Page 224 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Pigtails Tight Buffer
Optical performance pigtails
Fibre type
Connector Polishing Insertion loss max. Return loss min.
Multimode
ST-SC-LC
PC
0,3 dB
> 30 dB
Multimode
MT-RJ
PC
0,3 dB
NA
Singlemode ST-SC-LC
PC
0.3 dB
> 40 dB
Singlemode SC-LC
APC
0,3 dB
> 55 dB
Singlemode MT-RJ
NA
NA
NA
Pigtails tight buffer: available products
Fibre type Connector N-number
SM
SM APC
OM1
ST
N123.4TTY LANmark-OF Pigtail ST SM Tight Buffer LSZH 9/125 1m Yellow
SC
N123.4TCY LANmark-OF Pigtail SC SM Tight Buffer LSZH 9/125 1m Yellow
LC
N123.4TLY
SC
N120.4TDY LANmark-OF Pigtail SC SM APC Tight Buffered LSZH 9/125 1m Yellow
LC
N120.4TPY LANmark-OF Pigtail LC SM APC Tight Buffered LSZH 9/125 1m Yellow
MTRJ
N123.0TMO LANmark-OF Pigtail MTRJ OM1 Tight Buffer LSZH 62.5/125 1m Orange
ST
N123.0TTO LANmark-OF Pigtail ST OM1 Tight Buffer LSZH 62.5/125 1m Orange
N123.0TCO LANmark-OF Pigtail SC OM1 Tight Buffer LSZH 62.5/125 1m Orange
LC
N123.0TLO LANmark-OF Pigtail LC OM1 Tight Buffer LSZH 62.5/125 1m Orange
N123.5TMA LANmark-OF Pigtail MTRJ OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua
ST
N123.5TTA LANmark-OF Pigtail ST OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua
SC
N123.5TCA LANmark-OF Pigtail SC OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua
LC
N123.5TLA LANmark-OF Pigtail LC OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua
MTRJ
OM4
LANmark-OF Pigtail LC SM Tight Buffer LSZH 9/125 1m Yellow
SC
MTRJ
OM3
Description
N120.7TMA LANmark-OF Pigtail MTRJ OM4 Tight Buffer LSZH 50/125 1m Aqua
ST
N120.7TTA LANmark-OF Pigtail ST OM4 Tight Buffer LSZH 50/125 1m Aqua
SC
N120.7TCA LANmark-OF Pigtail SC OM4 Tight Buffer LSZH 50/125 1m Aqua
LC
N120.7TLA LANmark-OF Pigtail LC OM4 Tight Buffer LSZH 50/125 1m Aqua
03/12/10 - http://www.nexans.co.uk
Page 225 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Adaptors
03/12/10 - http://www.nexans.co.uk
Page 226 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Snap-In Adapter
Description
Application
LANmark-OF Snap-In adapters have been designed for snapping into the
modular OF patch panels and ZD boxes. They are available in single SC, dual
SC, LC duplex and MT-RJ version. The 2 Small Form Factor connector types
offer double density, as two bre connections are offered on the SC-type
footprint. Installation time is saved as the snap-in concept replaces the timeconsuming screwing attachment of coupling devices.
Performance
LC and SC versions are available in Multimode and Singlemode, MT-RJ is only
available in Multimode.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 227 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Snap-In Adapter
Product List
Nexans ref.
N205.611
N205.621
N205.614
N205.624
N205.612
N205.613
N205.623
Name
LANmark-OF Snap-In Adapter 2LC-2LC Multimode
LANmark-OF Snap-In Adapter 2LC-2LC Singlemode
LANmark-OF Snap-In Adapter DSC-DSC Multimode
LANmark-OF Snap-In Adapter DSC-DSC Singlemode
LANmark-OF Snap-In Adapter MT-RJ - MT-RJ
LANmark-OF Snap-In Adapter SC-SC Multimode
LANmark-OF Snap-In Adapter SC-SC Singlemode
=Make to order,
=Make to stock
Connector type
LC
LC
SC Duplex
SC Duplex
MT-RJ
SC
SC
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 228 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Standard Adaptors
Description
Standard format adaptors and couplers
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 229 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Standard Adaptors
Product List
Nexans ref.
N205.127
N205.158
N205.135
N205.131
N205.133
N205.153
N205.123
=Make to order,
=Make to stock
Name
Dual SC coupler MM
Dual SC coupler SM
LANmark-OF MTRJ adapter Multimode
LANmark-OF Quad LC Multimode adaptor
LANmark-OF Quad LC Singlemode adaptor
LANmark-OF Singlemode adaptor ST-ST
LANmark-OF adaptor Multimode ST-ST
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 230 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Tools & Accessories
03/12/10 - http://www.nexans.co.uk
Page 231 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Cleaning Tools
• Cleaning tools for cleaning bre connector and adaptors
• Cleaning tools for single connectors:SC,ST and LC
• Cleaning tools for male and female array connectors
Description
Cleaning op bre connectors and adaptors is extremely important to achieve
optimal optical performance and low loss connectivity. The Nexans’ cleaning
tools allow cleaning unmated connectors and can also clean connectors that are
installed in a patch panel. The cassette MPO cleaner allows cleaning effectively
unmated male MPO connectors.
Product List
Nexans ref.
N890.122
N890.125
N890.120
N890.121
Name
LANmark-OF LC Cleaning Tool
LANmark-OF MPO Cassette Cleaning Tool
LANmark-OF MPO Cleaning Tool
LANmark-OF SC/ST Cleaning Tool Standards
International ISO11801:2002/
= Make to order,
= Make to stock
A1:2008
03/12/10 - http://www.nexans.co.uk
Page 232 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Fibre Accessories
•
•
•
•
•
•
•
OF-LANmark accessories to complete the whole system.
OF splice trays
SC & ST connectors
SC & ST couplers
Fusion splice protection & Tool
Cable gland & splitter tube
Micro tube
Description
Application
• Optical bre accessories to complete all Nexans OF products, patch panels, ZD
boxes, splitter box.
• Designed for the installation of zone wiring, bre to the ofce, bre to the desk
and backbone connections.
Compatibility
Suitable for tight buffer cable (direct termination) or loose tube using splice tray
and pigtails
Compatible with all Nexans ST or SC patch panels, zone distribution boxes and
splice box
Installation
• The ST and SC connectors are in both versions hot melt or epoxy eld
installable for easy installing.
• The single ST and dual SC couplers are available in single mode and mono
mode to complete all OF structural hardware.
• The splice trays are easy to x in all Nexans OF patch panels, OF ZD boxes
and can distribute 12 optical bres.
• Cable glands can be useful for entering cables or distributing bres in to the OF
patch panels and OF ZD boxes.
• Aluminium fusion splice protection protect the spliced bres and are easily
manageable in the splice tray.
A
• tool is offered for easy installing the aluminium fusion splice protection.
• Splitter tube aloud to split up your cable into different patch panels.
• A blind plate completes the e-ssential patch panel when used as splice patch
panel.
• Micro tubes of 0.9mm can be used to install a hot melt connector on a loose
tube bre.
03/12/10 - http://www.nexans.co.uk
Standards
International ISO/IEC 11801
Page 233 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark-OF Fibre Accessories
Product List
Nexans ref.
N890.043
N441.132
N890.147
N890.146
N890.045
=Make to order,
=Make to stock
Name
Cable gland for splitter tube
Essential-OF Blind face plate (For splitter)
LANmark-OF Cable gland 20mm
LANmark-OF Cable gland 25mm
Microtube 0.9 mm
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 234 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Intelligent Infrastructure Management
LANsense is Nexans Intelligent Infrastructure Management (IIM) solution. It is an
internet enabled hardware and software package which can automatically
discover and monitor network connectivity in real-time, to ensure network
connections are secure and that connectivity documentation is always 100%
accurate. LANsense is vendor independent and can be retro-tted to existing
systems.
Benets:
•
•
•
•
•
•
Increased Security
Cost effective change control and management
Reduced downtime
Asset Management
Remote site monitoring
the ability to integrate, control, and manage building management services
(Access Control, intruder systems, CCTV, HVAC etc)
Nexans work in partnership with iTRACS, the leaders in IIM software, and offer
two levels of software:
• LANsense Enterprise - the full featured version requiring specialist
conguration
• LANsense - a pre-congured solution but with limited options for customisation.
These software solutions can be congured with different hardware products to
deliver specialist solutions for Data Centres, Enterprise, or SME customers with
branch networks.
For more information on becoming a Nexans Certied LANsense Partner please
contact us at [email protected]
03/12/10 - http://www.nexans.co.uk
Page 235 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Software
Choice of software functionality
Description
LANsense is Nexans Intelligent Infrastructure Management (IIM) solution. It is an
internet enabled hardware and software package which can automatically
discover and monitor network connectivity in real-time, to ensure network
connections are secure and that connectivity documentation is always 100%
accurate. LANsense is vendor independent and can be retro-tted to existing
systems.
Benets:
•
•
•
•
•
•
Increased Security
Cost effective change control and management
Reduced downtime
Asset Management
Remote site monitoring
the ability to integrate, control, and manage building management services
(Access Control, intruder systems, CCTV, HVAC etc)
Nexans work in partnership with iTRACS, the leaders in IIM software, and offer
three levels of software:
• LANsense
• LANsense Enterprise Edition
• LANsense Data Centre Edition
Standards
International ISO/IEC 11801
These software solutions can be congured with different hardware products to
deliver specialist solutions for Data Centres, Enterprise, or SME customers with
branch networks.
03/12/10 - http://www.nexans.co.uk
Page 236 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense EMAC
EMAC Products
Description
Corporate data centres are well known as signicant power users, with a large
sized data centre consuming similar amounts of power to an average sized town.
As data centres today generate more heat output and often suffer from
inadequate cooling, the need to operate efciently and cost effectively against
infrastructure and power constraints is increasing.
Obviously the greater capacity required, the greater impact on ensuring continuity
of supply. Add to this, the escalating cost of energy, and the requirement for
management information and control becomes evermore critical.
Nexans provides a range of standard intelligent power management capabilities,
for both new and existing builds specied for both power monitoring only, or a
combination of power monitoring with individual outlet control.
Standards
International Nexans specication
Dened upper and lower thresholds allow the client to differentiate between
warning and critical status, generating various alarms and alerts, with appropriate
escalation paths.
Aggregation of conguration information across data centre equipment, for
intelligent monitoring and alarm processing, provides ‘real time’ identication of
changes, scheduled polling and the ability to capture detailed data to produce
highly sophisticated and graphical management information reports, enabling
clients to perform trend analysis and risk management for mission critical
services.
Status information can be gathered either locally or remotely via secure
authenticated IP access (LDAP) monitoring RMS volts, amps, kVA, kWh, power
factor and frequency.
Detailed values and management information across device location, power and
cooling, network connectivity, asset application and customer information enable
us to present analysis on current and historical trending. This trend analysis can
be further utilised to help CIOs make informed decisions on capacity planning,
risk analysis, performance benchmarking and policing service level agreements.
To optimise both power consumption and energy use, our intelligent offerings
make it possible to meter actual power usage and produce trend data for any
single or group of physical systems, enabling:
•
•
•
•
•
•
•
Adequate capacity for existing & future needs
Monitoring, measuring & reporting of power usage via multiple clients
Billing stream capability for hosted clients
Prevention of unauthorised use of power outlets / equipment deployment
System load management (phase balancing, capacity planning etc)
Recovery of locked servers via remote IP power cycling
Alarming & trending of system, rack, powerstrip and outlet level overload
conditions.
RoHS conform
Yes
03/12/10 - http://www.nexans.co.uk
Page 237 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense EMAC
Characteristics
Usage characteristics
RoHS conform
Yes
RoHS conform
Yes
03/12/10 - http://www.nexans.co.uk
Page 238 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense EMAC
Product List
Nexans ref.
N878.21220
N878.32001
N878.32002
Nouveauté
N878.41004
Nouveauté
N878.41001
N878.41003
Nouveauté
N878.NIPM
Nouveauté
N878.22110
N878.24210
N878.22210
N878.22215
N878.11002
Nouveauté
N878.11003
Nouveauté
N878.11004
Nouveauté
N878.31001
N878.31002
Nouveauté
=Make to order,
=Make to stock
Name
LANsense Dual Supply Link Box 32A
LANsense Humidity Sensor 2m
LANsense Humidity Sensor RJ45
LANsense Magnetic Door Sensor RJ45 4m
LANsense Microswitch Door Sensor 4m
LANsense Microswitch Door Sensor RJ45 2m
LANsense Non-Invasive Power Monitor
LANsense PDU 32A 12x10A IEC C13 Horizontal
LANsense PDU 32A 16x10A IEC C13 Monitor and Control
LANsense PDU 32A 16x10A IEC C13 Vertical
LANsense PDU 32A 24x10A IEC C13 Vertical
LANsense Rack Manager II 6 Channel Autosensing
LANsense Row Controller 12 Channel Autosensing
LANsense Row Controller Expansion Module
LANsense Temperature Sensor 2m
LANsense Temperature Sensor RJ45 2m
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 239 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense Cu panel
• LANsense IIM compatible
• Empty for use with modular connectors sold separately
Description
LANsense copper patch panels carry on-board intelligence which remains
dormant until enabled by LANsense analysers and software. The panels have inbuilt sensors to detect the connection status of each port and an I/O connector to
link to the analysers.
Manufactured from steel, the panel provides a robust, high density mounting
mechanism for Nexans modular connectors.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 240 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense Cu panel
Characteristics
Usage characteristics
I/O Connector - Panel
Product List
Nexans ref.
N881.011
N881.051
Nouveauté
195513-1001
Remplacé
N881.671
Nouveauté
N881.681
Remplacé
N881.685
Remplacé
N881.675
Nouveauté
N881.411
Nouveauté
N881.311
Nouveauté
N881.111
Remplacé
N881.151
Remplacé
N881.351
Nouveauté
N881.251
Remplacé
N881.255
Remplacé
N881.451
Nouveauté
N881.455
Nouveauté
N881.061
Nouveauté
Type 2
=Make to order,
=Make to stock
Name
LANsense 24 Way Patch Panel for 808 connectors
LANsense 24 Way Patch Panel for 808 connectors
LANsense 24 Way Patch Panel for 808 connectors (ITT branded)
LANsense Angled Panel 24 Snap-In Black
LANsense Angled Panel 24 Snap-In GG45 Black
LANsense Angled Panel 24 Snap-In GG45 White
LANsense Angled Panel 24 Snap-In White
LANsense Empty Sliding Patch Panel for 24 Snap-In connectors, Black
LANsense Panel 24 Snap-In Black
LANsense Panel 24 Snap-In GG45 Black
LANsense Upgrade Frontplate for Fixed Modular Panel 24 GG45-type snap-in connectors, Black
LANsense Upgrade Frontplate for Fixed Modular Panel 24 Snap-In connectors, Black
LANsense Upgrade Frontplate for Sliding Modular Panel 24 GG45-type snap-in connectors, Black
LANsense Upgrade Frontplate for Sliding Modular Panel 24 GG45-type snap-in connectors, White
LANsense Upgrade Frontplate for Sliding Modular Panel 24 Snap-In connectors, Black
LANsense Upgrade Frontplate for Sliding Modular Panel 24 Snap-In connectors, White
LANsense Upgrade for 24 port 808 Modular Panel
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 241 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cu Patch Cords
•
•
•
•
•
9th pin for port detection
Ensures maximum channel performance
Cat 5e & Cat 6 & Cat 6A/10G
Screened & Unscreened
Available in different lengths
Description
The Nexans LANsense patchcord range is suitable for use in voice or data
network installations. The 4 pair construction and robust RJ45 connectors provide
for long term network reliability. The patchcords have an unobtrusive external
probe built into the plug boot which mates with the sensors built into the patch
panels. The patchcords can be supplied in different lengths and with different
colour latch protectors to allow differentiation of services and workgroups.
Standards
International EN 50265-2-1; ISO/
IEC 11801
National TIA/EIA-568-B.2
03/12/10 - http://www.nexans.co.uk
Page 242 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cu Patch Cords
Product List
Nexans ref.
LDWPCS010L0U10
LDWPCS020L0U10
LDWPCS030L0U10
LDWPCS050L0U10
LDWPCU010L0U10
LDWPCU020L0U10
LDWPCU030L0U10
LDWPCU050L0U10
LEWPCS010L0U10
LEWPCS020L0U10
LEWPCS030L0U10
LEWPCS050L0U10
195600-5010-3
195600-5020-3
195600-5030-3
195600-5050-3
N88A.P1F015OK
Nouveauté
N88A.P1F010OK
Nouveauté
N88A.P1F020OK
Nouveauté
N88A.P1F030OK
Nouveauté
N88A.P1F050OK
Nouveauté
=Make to order,
=Make to stock
Category Length (m) Screen
Cat. 5e
1
FTP
Cat. 5e
2
FTP
Cat. 5e
3
FTP
Cat. 5e
5
FTP
Cat. 5e
1
UTP
Cat. 5e
2
UTP
Cat. 5e
3
UTP
Cat. 5e
5
UTP
Cat. 6
1
FTP
Cat. 6
2
FTP
Cat. 6
3
FTP
Cat. 6
5
FTP
Cat. 6
1
UTP
Cat. 6
2
UTP
Cat. 6
3
UTP
Cat. 6
5
UTP
Name
LANsense 5e FTP PVC P/Cord 1m
LANsense 5e FTP PVC P/Cord 2m
LANsense 5e FTP PVC P/Cord 3m
LANsense 5e FTP PVC P/Cord 5m
LANsense 5e UTP PVC P/Cord 1m
LANsense 5e UTP PVC P/Cord 2m
LANsense 5e UTP PVC P/Cord 3m
LANsense 5e UTP PVC P/Cord 5m
LANsense 6 FTP PVC P/Cord 1m
LANsense 6 FTP PVC P/Cord 2m
LANsense 6 FTP PVC P/Cord 3m
LANsense 6 FTP PVC P/Cord 5m
LANsense 6 UTP PVC P/Cord 1m
LANsense 6 UTP PVC P/Cord 2m
LANsense 6 UTP PVC P/Cord 3m
LANsense 6 UTP PVC P/Cord 5m
LANsense Patch Cord Cat 6A LSZH Screened 1.5m Orange
Cat. 6a
1.5
FTP
LANsense Patch Cord Cat 6A LSZH Screened 1m Orange
Cat. 6a
1
FTP
LANsense Patch Cord Cat 6A LSZH Screened 2m Orange
Cat. 6a
2
FTP
LANsense Patch Cord Cat 6A LSZH Screened 3m Orange
Cat. 6a
3
FTP
LANsense Patch Cord Cat 6A LSZH Screened 5m Orange
Cat. 6a
5
FTP
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 243 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre Panels
• LANsense IIM compatible
• 24, 48 or 96 bre in 1HU versions
• Available for LC and SC connectors
Description
The LANsense range of patch panels provide a high density transition between
building cables and active equipment.
Very high density versions are available with up to 96 bre (48 ports) with LC for
data centre environments.
Standard 24 or 48 bre version with SC connections are also available.
A variety of cable entry holes are located at the rear of the panels to allow a wide
range of cable variants to be accommodated. Cable entry hole blanks and bre
management are included with the panel. A complementary range of cable
glands, that are supplied separately, ensure that cables are secured and enter the
panel in a controlled manner. A simple to remove lid gives easy access to the
panel interior.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 244 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre Panels
Product List
Nexans ref.
N883.131
Jusqu'à épuisement du
stock
N883.221
Nouveauté
N883.261
Nouveauté
N883.133
Nouveauté
N883.223
Nouveauté
N883.233
Nouveauté
N883.182
Nouveauté
N883.181
Nouveauté
N883.2B48LCMM
Nouveauté
N883.2B48LCSM
Nouveauté
=Make to order,
=Make to stock
Connector
I/O Connector type
Panel
Name
LANsense 24 SC Singlemode Patch Panel
SC
Type 1
LANsense 48 Fibre LC Multimode Patch Panel
LC
Type 2
LANsense 48 LC Multimode Patch Panel Black
LC
Type 2
LANsense 48 SC Singlemode Patch Panel
SC
Type 2
LANsense 96 LC Multimode Patch Panel
LC
Type 2
LANsense 96 LC Singlemode Patch Panel
LC
Type 2
LANsense Fibre Panel 24 SC Multimode Black
SC
Type 2
LANsense Fibre Panel 24 SC Singlemode Black
SC
Type 2
SC
Type 1
SC
Type 2
LANsense Pre-Loaded Patch Panel 48 LC Multimode
Sliding Black
LANsense Pre-Loaded Patch Panel 48 LC
Singlemode Sliding Black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 245 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre patchcords
• Additional copper pin for port detection
• High bandwidth OM3 bre
• Available with LC, MTRJ, or SC connectors
Description
The MTRJ, SC and LC LANSense patch cord uses the standard MTRJ, SC and
LC duplex connector, enabling high-density ber connections to be achieved. The
MTRJ, SC and LC LANSense cord however has an over-boot to incorporate the
sensing capability of the LANSense products. The LANSense patch cords are
available in both high bandwidth OM3 and single-mode OS2 bre types and so
offer a comprehensive range of patch cords for interfacing with the latest network
equipment.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 246 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Fibre patchcords
Product List
Nexans ref.
N884.5LLP1
N884.5LLP2
N884.5LLP3
N884.5LLP5
N884.4LLY1
N884.4LLY2
N884.5MMP1
Jusqu'à épuisement du stock
N884.5MMP2
Jusqu'à épuisement du stock
N884.5MMP3
Jusqu'à épuisement du stock
N884.5MMP5
Jusqu'à épuisement du stock
N884.5CCP1
N884.5CCP2
N884.5CCP3
N884.5CCP5
N884.4CCY1
N884.4CCY2
N884.4CCY3
N884.4CCY5
=Make to order,
=Make to stock
Length (m) Connector type
1
LC
2
LC
3
LC
5
LC
1
LC
1
LC
Name
LC Duplex LANsense P/Cord 50/125 OM3 - 1m
LC Duplex LANsense P/Cord 50/125 OM3 - 2m
LC Duplex LANsense P/Cord 50/125 OM3 - 3m
LC Duplex LANsense P/Cord 50/125 OM3 - 5m
LC Duplex LANsense P/Cord 9/125 OS1 - 1m
LC Duplex LANsense P/Cord 9/125 OS1 - 2m
MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 1m
1
MT-RJ
MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 2m
2
MT-RJ
MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 3m
3
MT-RJ
MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 5m
5
MT-RJ
SC Duplex LANsense P/Cord 50/125 OM3 - 1m
SC Duplex LANsense P/Cord 50/125 OM3 - 2m
SC Duplex LANsense P/Cord 50/125 OM3 - 3m
SC Duplex LANsense P/Cord 50/125 OM3 - 5m
SC Duplex LANsense P/Cord 9/125 OS2 - 1m
SC Duplex LANsense P/Cord 9/125 OS2 - 2m
SC Duplex LANsense P/Cord 9/125 OS2 - 3m
SC Duplex LANsense P/Cord 9/125 OS2 - 5m
1
2
3
5
1
2
3
5
SC
SC
SC
SC
SC
SC
SC
SC
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 247 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense Analysers
•
•
•
•
1U version up to 256 ports
6U version from 512 to 2048 ports
Master and Link variants enabling upto 20480 ports per IP address
Virtually unlimited scalability
Description
A LANsense analyser is required to monitor all network ports, record changes
in the events log, and continuously update and maintain the connectivity
database. It connects to the equipment presentation panel or integration strip and
the horizontal distribution panel using I/O cables, and is in turn connected to the
LANsense cable management SQL database.
It should be noted that 2 analyser ports (one for the horizontal connection and
one for the system connection) are required for each user channel to be
monitored.
Master and Link analysers can be connected to form a star wired network capable
of monitoring up to 20480 ports in a "patch zone" using a single IP address.
Multiple patch zones can be connected to a single database providing almost
unlimited scalability.
Standards
International UL and CSA approval
03/12/10 - http://www.nexans.co.uk
Page 248 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense Analysers
Product List
Nexans ref.
LXWANLL0101
Remplacé
LXWANLM0101
Remplacé
LXWANLS0101
Remplacé
195560-0603
Remplacé
195560-0602
Remplacé
195560-0601
Remplacé
N870.1UL
Nouveauté
N870.1UM
Nouveauté
N870.6UL
Nouveauté
N870.6UM
Nouveauté
=Make to order,
=Make to stock
I/O Connector - Analyser
Name
LANsense 1U Link Analyser
Type A
LANsense 1U Master Analyser
Type A
LANsense 1U Standalone Analyser
Type A
LANsense 6U Link Analyser
Type A
LANsense 6U Master Analyser
Type A
LANsense 6U Standalone Analyser
Type A
LANsense Analyser 1U Link - MarkII
Type B
LANsense Analyser 1U Master - MarkII
Type B
LANsense Analyser 6U Link - MarkII
Type B
LANsense Analyser 6U Master - MarkII
Type B
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 249 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
NGA
• Next Generation Analyser
• Seperate analyser and display functions
• Increased density
• Supports additional functionality
• Simplied and more exible system design
Description
The Next Generation Analyser is an exciting new development which opens up
many possibilities for efcient analyser network design and advanced functionality
to support the LANsense platform
Key features
•
•
•
•
•
•
•
•
•
•
•
System Master Card (SMC) running Linux OS
Self diagnostic test and health status
No Cooling required
Detects up to 8 connections on a single port
9th wire electrostatic protection
Analyzer Card (AC) hot swap support
Automated rmware distribution/installation
Conguration by any Windows XP device
Multiple deployment options
Software control of Smart Patch Panel (SPP) interfaces
“Plug and Play” deployment
03/12/10 - http://www.nexans.co.uk
Standards
International ISO/IEC 11801
Page 250 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
NGA
Product List
Nexans ref.
N870.PSU2
Nouveauté
N870.3UC
Nouveauté
N870.3UL
Nouveauté
N870.3UM
Nouveauté
N870.PSU7
Nouveauté
N870.ACC
Nouveauté
N870.SPP
Nouveauté
N870.SMC
Nouveauté
N870.UPP
Nouveauté
=Make to order,
=Make to stock
Name
LANsense NGA 2 Amp Power Supply Unit
LANsense NGA 3U Card Cage
LANsense NGA 3U Card Cage Link Cover
LANsense NGA 3U Card Cage Master Cover
LANsense NGA 7 Amp Power Supply Unit
LANsense NGA Analyser Card
LANsense NGA HMI Panel 1U
LANsense NGA System Master Card
LANsense NGA USB Interface Adaptor
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 251 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense I/O and Master/Link cables
• I/O cables for analyser to panel connection
• Master/Link for Master analyser to Link analyser connection
Description
LANsense accessory cables are divided into two sub families:
Master / Link cables are used to interconnect Master and Link and analysers to
form a star wired analyser network capable of monitoring a patch zone of up to
20480 ports. Multiple patch zones can exist within a LANsense database
I/O cords are used to connect LANsense patch panels or integration strips to
the analysers. The 12 way adaptor and 3 x 8 Way splitter are used to maximise
the usage of analyser ports within an installation.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 252 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense I/O and Master/Link cables
Product List
Nexans ref.
LXWCCL160XOO
LXWCCL030XOO
LXWCCL040XOO
LXWCCL080XOO
196102-0019
LXWCCP021A20
196102-0028
LXWCCP030A20
196102-0040
LXWCCP043A20
N871.CIO0010
Nouveauté
N871.CIO003
Nouveauté
N871.CIO005
Nouveauté
N871.NIOH0010
N871.NIOH0100
N871.NIOH0020
N871.NIOH0050
Name
Analyser M/L Cord 16.0m
Analyser M/L Cord 3.0m
Analyser M/L Cord 4.0m
Analyser M/L Cord 8.0m
I/O Cord 24 way - 1.9m
I/O Cord 24 way - 2.1m
I/O Cord 24 way - 2.8m
I/O Cord 24 way - 3.0m
I/O Cord 24 way - 4.0m
I/O Cord 24 way - 4.3m
LANsense I/O Cable PVC Type C
Rev 2 10m
LANsense I/O Cable PVC Type C
Rev 2 3m
LANsense I/O Cable PVC Type C
Rev 2 5m
Mark II I/O Cable 24 way - 1.0m
Mark II I/O Cable 24 way - 10.0m
Mark II I/O Cable 24 way - 2.0m
Mark II I/O Cable 24 way - 5.0m
Mark II I/O Cable Adaptor 12 way N871.NIOHA2X12
150mm
Mark II I/O Cable Splitter 3 x 8 way N871.NIOH0102
350mm
I/O Connector Analyser
N/A
N/A
N/A
N/A
Type A
Type A
Type A
Type A
Type A
Type A
=Make to order,
I/O Connector Panel
N/A
N/A
N/A
N/A
Type 2
Type 1
Type 2
Type 1
Type 2
Type 1
=Make to stock
Mat length
(m)
16
3
4
8
1.9
2.1
2.8
3
4
4.3
Type C
Type 2
10
Type C
Type 2
3
Type C
Type 2
5
Type B
Type B
Type B
Type B
Type 2
Type 2
Type 2
Type 2
1
10
2
5
Type B
N/A
0.2
Type B
N/A
0.4
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 253 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANsense Integration Strips
• LANsense IIM compatible
• Integration Strips designed for specic equipment
Description
LANsense Integration Strips are used to provide LANsense port detection
functionality on non LANsense enabled products like switches in an interconnect
environment.
They are used instead of a system side or port replication panel (used in a crossconnect environment) and allow LANsense cords to be connected directly into
active equipment.
Integration strips are usually provided to t 24 port devices but other port counts
can be accomodated.
In order to create an Integration Strip a template is used to accurately
communicate the dimensions and port layout of the device.
Standards
International Nexans specication
03/12/10 - http://www.nexans.co.uk
Page 254 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Industrial LAN & Harsh Environments
03/12/10 - http://www.nexans.co.uk
Page 255 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry Copper cables
Description
Copper cables for LANs in industrial and exposed areas.
Standards
International ISO/IEC 11801; ISO/
IEC 24702
03/12/10 - http://www.nexans.co.uk
Page 256 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry Copper cables
Product List
Nexans ref.
N10i.002
N10i.004
Name
LANmark Industry S/FTP AWG23 PUR black 500m reel
LANmark Industry SF/UTP AWG24 LSZH+PE black 500m reel
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 257 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry Optical Fibre cables
Description
Fibre optic cables for LANs in industrial and exposed areas.
Standards
International ISO/IEC 11801; ISO/
IEC 24702
03/12/10 - http://www.nexans.co.uk
Page 258 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry Optical Fibre cables
Product List
Nexans ref.
N165.922
Name
LANmark Industry TBX 6x multimode 50/125 OM3 PUR black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 259 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry DIN-Rail Outlets and boxes
Description
DIN-Rail mount Outlets and boxes for LANs in industrial and exposed areas.
Standards
International ISO/IEC 11801; ISO/
IEC 24702
03/12/10 - http://www.nexans.co.uk
Page 260 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry IP65/67 outlets
LANmark Industry IP67 outlets
Description
IP65/67 outlet for LANs in industrial and exposed areas.
Standards
International ISO/IEC 11801; ISO/
IEC 24702
03/12/10 - http://www.nexans.co.uk
Page 261 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry IP65/67 outlets
Product List
Nexans ref.
N42i.001
N42i.002
Name
LANmark Industry IP65/67 outlet kit 2 Snap-In Category 6 black
LANmark Industry IP65/67 outlet kit 2 Snap-In Category 6A black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 262 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry patch cord RJ45 IP67/IP20 Cat.6
Description
Patchcords IP67/IP20 for LANs in industrial and exposed areas.
Standards
International ISO/IEC 11801; ISO/
IEC 24702
03/12/10 - http://www.nexans.co.uk
Page 263 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Industry patch cord RJ45 IP67/IP20 Cat.6
Product List
Nexans ref.
N10i.E34DJ
N10i.E34DJ
N10i.E34OJ
N10i.E34FJ
N10i.E34HJ
=Make to order,
=Make to stock
Name
LANmark Industry patch cord RJ45 IP67 Single-end Category 6 screened PVC 10m Yellow
LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 1.5m Yellow
LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 10m Yellow
LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 3m Yellow
LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 5m Yellow
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 264 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
General Accessories & Cabinets
Nexans have a complete range of accessories and hardware to complete the LAN
system
03/12/10 - http://www.nexans.co.uk
Page 265 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Datacenter racks and frames
•
•
•
•
•
19-Inch mounting equipment for high-density cross-connect
Ideal in Datacenters
Designed to host both Copper and Fibre cabling
Robust metal construction
Enhanced access and cord management
Description
Standards
Application
LANmark High-Density racks and frames have been designed to host busy
Cross-Connects in datacenters. Specic attention has been given to technical
constraints of datacenters such as cooling and space scarcity. Numerous features
contibute to an optimal space utilisation and enable installation on busy
datacenter oors. These High-Density racks and frames enable excellent front,
rear and lateral access. This is of great importance during installation but
also during maintenance and upgrade operations. Proper management of large
numbers of cords and securing clarity is critical for datacenters management and
reliability over the life time. Examples of equipment that can be hosted in
LANmark High-Density rack and frames are given below:
•
•
•
•
•
•
•
•
International ISO/IEC 11801:2002/
A2:2008
Angled panels and accessories
High Density Fibre optic panels
MPO panels
LANsense - Intelligent patching
Suitable for Cat.6A, 7 and 7A
Suitable for OM3, OM4 anD OS2
future Cat 6A and Class EA applications
EMAC - Environmental control
Performance
LANmark High-Density racks and frames have been designed to host all
LANmark bre optic and copper products.
Installation
Nexans LANmark-6 feature accessories and bracket enabling the installtion in
various conguration and location of a datacenter. please see the datasheet of
the main products for details.
Guarantees
Nexans LANmark High-Density Rack and Frames are covered by a parts and
labour warranty as described in the Nexans Certied System Warranty.
03/12/10 - http://www.nexans.co.uk
Page 266 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Datacenter racks and frames
Product List
Nexans ref.
N345.000
Nouveauté
N345.012
Nouveauté
N345.400
Nouveauté
Name
LANmark High-Density Cross-Connect Cabinet 42U - Basic
LANmark High-Density Cross-Connect Cabinet 42U - incl. Doors and Lateral Panels
LANmark Overhead Patching Frame 4U
= Make to order,
= Make to stock
Selling delivery information
Delivery info: Datacenter racks and frames
03/12/10 - http://www.nexans.co.uk
Page 267 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Patch Guides, Blank Panels & Cable Management
•
•
•
•
Patch guides to manage and store all patch cords.
1 HU and 2 HU for high density.
1 HU with rings for easy access.
Cable guide for all patch panels without clip-on.
Description
For a correctly managed installation, Nexans offers a full range of cable
management accessories to complement our patch panel and cabinet range. The
range is suitable for all Nexans Copper and Optical patch panels.
The new offering is Nexans branded to blend with other Nexans products used in
a cabinet.
The cable management range is designed for all 19" cabinets. The range includes
patch guides and cable guides.
Patch Guides
The Nexans patch guide range enables orderly patch cord storage. All the
Nexans accessories are guaranteed to maintain the required bending radius for
patch cords which in turn ensures superior data transmission for the installation.
The paint nished metal accessories provide improved stability over plastic
guides on the market.
The 1HU and 2HU universal patch guides are delivered with a front plate. The 8
cm depth provides for the bending radius and enough storage space for the patch
cords. Two openings designed at the rear face improve the storage and entry
possibilities for patch cords.
Standards
International ISO/IEC 11801
An alternative 1 HU 5- ring metal patch guide is offered. This accessory similarly
allows for orderly patch cord management in any installation.
Cable Guide
The Nexans cable guide offers fast and reliable cable retention and grounding.
The clip-on system is a proprietary Nexans design and improves the exibility,
solidity and the grounding of your installation.
03/12/10 - http://www.nexans.co.uk
Page 268 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Patch Guides, Blank Panels & Cable Management
Product List
Nexans ref.
N109.207
N109.207BK
Nouveauté
N102.105BK
N102.105
N102.117BK
N102.117
N102.127BK
N102.127
N521.672
Nouveauté
N521.673
Nouveauté
N521.678
Nouveauté
N424.512
N102.115BK
=Make to order,
Name
1HU Blank Panel
1HU Blank Panel, black
=Make to stock
Colour
White RAL 9002
Black
1HU Patch Guide with rings, Black
1HU Patch Guide with rings, White
1HU Universal Patch Guide with front cover, Black
1HU Universal Patch Guide with front cover, White
2HU Universal Patch Guide, Black
2HU Universal Patch Guide, White
Black
White RAL 9002
Black
White RAL 9002
Black
White RAL 9002
Angled Blank Panel Black
Black
Angled Panel Cover Black
Black
Angled Pass-Through Black
Black
Cable management plate for Essential Rear Connect Panels N424.xxx
Letterbox Patch Guide 1HU Black
Black
Black
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 269 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Zone Distribution Boxes
•
•
•
•
For use as consolidation point.
Compatible with all LANmark snap-in connectors.
6 or 12 numbered snap-in ports with shutters.
Easy to install
Description
Designed for use as consolidation points, zone distribution boxes signicantly
increase the exibility of desk locations in open ofce environments. They are
particularly useful in ofces where frequent relocation of outlets in the work area
is required.
Nexans ZD boxes are easy to install on walls, under raised oors or in ceiling
voids, due to their multiple mounting features.
They are compatible with all LANmark snap-in connectors, which can be easily
inserted by a simple "one-click" movement.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 270 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
LANmark Zone Distribution Boxes
Characteristics
Construction characteristics
Material
Usage characteristics
Field of application
Product List
Nexans ref.
N521.600
N521.606BK
Nouveauté
N521.606
Nouveauté
Steel
Fixed installations
Name
LANmark ZD box 12 Snap-In White
Width (mm)
230
=Make to order,
=Make to stock
Colour
Height (mm) Depth (mm)
White RAL 9002
45
200
LANmark ZD box 6 Snap-In Black
120
Black
42
125
LANmark ZD box 6 Snap-In White
120
White RAL 9002
42
125
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 271 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinets - Quick Mount
Cabinets and Enclosures
•
•
•
•
•
19" cabinet and extension 42 HU 800X800
at pack : easy and quick installation
exclusive automatic earthing system
security
complete range of accessories
Description
Features
High Quality Cabinet for installation of Nexans Cabling Solutions Products.
Extremely easy and fast to install and hence very cost effective, thanks to
•
•
•
•
•
•
•
•
•
•
•
•
•
Delivery in separate parts which can be handled by only one person
Fast and exible mounting within a few minutes
Open structure which allows a free accessibility from all sides
Easy to add or remove products after the cabinet has been installed
Automatic earthing
IP 20 (can be upgraded to IP 30 by asdding an extra roof)
Possibility to x on the roof one to 8 individual fan
Easy to add extensions or to replace panels
Front and rear frames which can be installed in 3 different positions
Glass mixed front door
Only one standard tool required
No small loose parts
Secure your installation : front and rear door with eurolock and inside opening
system for side panels
Standards
International ISO/IEC 11801
Light weight cabinet.
All parts are packed in 6 small boxes which are very easy to manoeuvre.
Several accessories are available for enhanced functionality.
Door in tinted safety glass.
03/12/10 - http://www.nexans.co.uk
Page 272 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinets - Quick Mount
Product List
Nexans
ref.
N340.103
Nouveauté
N340.003
Nouveauté
Name
Width
(mm)
Depth
(mm)
Approximate net weight
(kg)
EXTENSION FOR QUICK MOUNT III 42HU
800x800
800
800
145.0
QUICK MOUNT III 42 HU 800x800
800
800
145.0
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 273 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinets - Wall Mountable
Cabinets and Enclosures
Wall Mountable
• 3 parts 19" wallmount 18HU
• Easy installation
Description
A range of wall mountable cabinets for locations where space is a premium.
Includes standard 19" cabinets and empty enclosers suitable for copper or bre
accessories.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Hinged 3 part design for easy access
extremely accessible swing frame design. (140mm for back part)
Top and Bottom cable entry equipped with brushes
Same functionalities as full size cabinet : 19" mounting frame
Cable xing plates on the rear panel for tie wrap
Hole for up to 3 individual fans on top and bottom
60 Kg Load
Included a 1/1 scale template paper for screw hole preparation before
installation
vertical metal patch guide system on the front for easier handling
Ideal for locations where space is at the premium
security with a lock on the door
tinted safety glass mixed door
dimensions : 18HUX500mmx650mm
03/12/10 - http://www.nexans.co.uk
Standards
International
Manufacturer specication
Page 274 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinets - Wall Mountable
Product List
Nexans ref.
N102.118
Nouveauté
Name
Wall Mount Cabinet 18 HU Mixed Door New Concept
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 275 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinet Accessories
Cabinet and Enclosure Accessories Range
Complete Range : shelves, spare parts, fans, powerbar,...
Description
Standards
Complete range of accessories for 19" cabinets and enclosures
•
•
•
•
•
International ISO/IEC 11801
Spare parts
Shelf
Powerbar
Ventilator Fan
...
03/12/10 - http://www.nexans.co.uk
Page 276 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Cabinet Accessories
Product List
Nexans ref.
N108.109
Remplacé
N108.109BK
Nouveauté
N203.167
N303.162
N303.163
ISCS71003WMP01
Remplacé
N333.165
N343.206
N203.158
N333.207
N203.156
N203.165
N203.160
N203.160A
N303.164
N101.001
N201.171
N203.171
N340.185
N343.209
N343.204
N343.208
N343.102
N343.201
N343.202
N343.213
N343.205
N343.203
=Make to order,
=Make to stock
Name
100 x Caged nut (M6) + screw (M6*12)
100 x Caged nut (M6) + screw (M6*12), black
19 inch SHELF FOR 12/18HU CABINET
19 inch shelf (36-42HU)(max. 70 kg, 2 xation points)
19" SHELF (MAX. 70 KG) WITH 4 FIX.POINTS
1U Blank Panel
4 x ADJUSTABLE FEET FOR QUICK-MOUNT
8xpatch ring
CLOSET DOC.HOLDER
DOOR HANDLE FOR REAR PANELS OF Quick Mount
NEON LAMP FOR CABINETS
Power Bar 19 inch 1 HU 6 UK outlet
Power Bar 19 inch 1 HU 6 UTE outlet + autofuse
Power Bar 19 inch 1 HU 6 schuko outlet + autofuse
SLIDING SHELF 19 inch pull out 1/3 maximum load of 30 Kg
Signal grounding key
Ventilator fan (110 V) + Power cable
Ventilator fan (230 V) + Power cable
additional plinth for quick mount
additional roof (IP 30) for quick mount
base for quick mount II & III
closing plate for quick mount II
connection kit for quick mount II & III extension cabinet
front door for quick mount II & III
rear door for quick mount II
rear door for quick mount II & III
roof for quick mount II & III
side panel for quick mount II & III
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 277 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Miscellaneous Accessories
Description
Nexans have a complete range of accessories and hardware to complete the LAN
system such as multicoloured shutters.
Standards
International ISO/IEC 11801
03/12/10 - http://www.nexans.co.uk
Page 278 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Miscellaneous Accessories
Product List
Nexans ref.
N420.655
N421.701
N421.701R
N421.701B
N421.701G
N421.701Y
N421.701GR
N421.701BK
Nouveauté
N420.050
Nouveauté
N420.655BK
Nouveauté
N108.111
Nouveauté
=Make to order,
=Make to stock
Name
Blank Snap-In ller for unused port, white
White shutter for Snap-In structural hardware
Red shutter for Snap-In structural hardware
Blue shutter for Snap-In structural hardware
Green shutter for Snap-In structural hardware
Yellow shutter for Snap-In structural hardware
Grey Shutter for Snap-In Structural Hardware
Black shutter for Snap-In structural hardware
Dust cap for RJ45
Blank Snap-In ller for unused port, black
Dzus quarter-turn fastener
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 279 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Software, Training, & Services
Adding value to Local Area Networks is about much more than high quality
products.
Nexans provide a range of tools and services, either directly or in conjunction with
business partners, to provide an unrivalled service & support package to meet the
demands of both installers and end users alike.
03/12/10 - http://www.nexans.co.uk
Page 280 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
System Warranty Programs
A parts guarantee is one thing. But what happens when you put them together?
Many companies may be specialised in one area but what happens if you have an infrastructure problem between buildings
– who is responsible for deciding if it is the copper or bre campus link at fault.
With a Nexans solution you don’t have to worry because we cover the complete cabling system, regardless of transmission
medium or the building topology:
• Copper, and Fibre
• Horizontal, Backbone or Campus
Nexans understands different cabling technologies and the building infrastructure, so that’s what we cover with the warranty.
Description
A company's communication system is crucial to its industrial and commercial
success. Every single day, every company depends on the quality and distribution
of information.
With global experience, technological mastery in various building architecture,
and a broad portfolio of products, Nexans matches the solution to your needs.
Nexans empowers your local area networking infrastructure to do better and
faster business.
Offering Quality of Service to your users and customers is the reference for your
success. Quality of Transmission, the performance of your infrastructure,
becomes more important and critical.
Our state-of-the-art solutions are your best guarantee for :
• performance
• reliability
• value for money
Standards
International
Manufacturer specication
03/12/10 - http://www.nexans.co.uk
Page 281 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Network Design Tools
Nexans Visio Templates (NVT) version 3.00 (NEW) is now available for download to enable users to create fast professional
cabinet layout drawings and includes new enhanced features.
NVT3 can be freely downloaded and includes now 6 intelligent product libraries (stencils) working under MS Visio to easily
create professional Distributor layouts.
Discover our Nexans Easy Design 1.0 software
NED saves time,reduces design and BoM errors.
NED is using a simple intuitive user interface to quickly collect the cabling project data and by using the shapes from the
Nexans Visio Template library plus a new NED library it will provide the user with:
• The Building conguration layouts
• The Distributor rack congurations including data about horizontal distribution and cords
• The full and complete Bill of Material of the cabling system
Description
Standards
International
Manufacturer specication
03/12/10 - http://www.nexans.co.uk
Page 282 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Network Design Tools
Product List
Nexans ref.
Toolkit
NVT
Name
LAN Calculation Toolkit
Nexans Visio Template 3.1 with NVT 3D
= Make to order,
03/12/10 - http://www.nexans.co.uk
= Make to stock
Page 283 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Contact
LAN Systems (Nexans Cabling Solutions)
Phone: +44 (0)1256 486640
[email protected]
Training Services
Nexans Cabling Solutions has elaborated its training program.
Training is given at the Competence Centres in Brussels or Basingstoke, or on demand at your premises or in one of our
regional Training Centres.
Description
No matter what your level is, we'll nd the best training program meeting all of
your needs. The LAN technology evolution requires a wide and varied range of
skills. No two projects are the same and our partner's position is important in this
business. The aim is to nd the synergy between your needs and our training
program.
In order to make this "level training" program possible, the training has been
divided into different modules to address different topics aimed at different people.
•
•
•
•
•
Installers
Project Managers
Designers, Consultants and Architects
Commercial Staff that would like to improve their sales techniques End Users
Anybody involved in cabling that would like to improve his knowledge and skils
in this domain
Trainees can obtain a "Nexans Cabling Solutions Expert level certication" when
they succeed in the 3-day Expert training.
It is clear that a new VAR, Distributor, or Certied System Installer will be required
to succeed in the Expert training. If the new partner has no experience it is
recommended that he will rst attend the basic training. If the partner has
previous experience, he can directly follow the Expert training.
Standards
International
Manufacturer specication
Training Modules Overview
Commercial:
Module 3: Nexans Copper Cabling Solutions
Module 8: Nexans Optical Fibre Cabling Solutions
Expert Knowledge:
Module 1: Premises Cabling Standards
Module 2: Parameter for Copper Cabling
Module 4: Installation Rules and Guidelines
Module 7: Optical Fibre Theory and Principles
Module 12: Design Training: Project Study
Module 14: Design Training: Project Engineering
Module 16: Project Management
Hands-on:
Module 5: Installation Practice & Testing Class D-E Links
Module 6: Installation Practice & Testing Class F Links
Module 9: Fibre Installation Practice with Direct Termination
Module 10: Fibre Installation Practice on Fusion Splicing
Module 11: Testing Optical Fibre Links
Module 13: Nexans Easy Design Visio Software
03/12/10 - http://www.nexans.co.uk
Page 284 / 285
All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of
Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
LANMARK-6A - OPTIMISE SHORT LINKS
10G
80% of Data Centres will
implement 10G in the coming
years. Exceeding Category 6A
standards, LANmark-6A enables
short link support avoiding space
problems by overlength cables.
Screened technology eliminates
alien crosstalk ensuring easy
installation and on-site testing.
LANmark-6A: Zero Risk 10G
w w w. n e x a n s . c o m / L A N s y s t e m s
[email protected]
G l o b a l e x p e rt i n c a b l e s
a n d c a b l i n g s y s te m s
01/2011 © Nexans Cabling Solutions
Global expert in cables and cabling systems
Nexans Cabling Solutions - Alsembergsesteenweg 2, b3 - B-1501 Buizingen - Belgium
Tel: +32 2 363 38 00 - Fax: +32 2 365 09 99 - www.nexans.com/LANsystems
[email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement