Nexans Cabling Solutions LAN Systems Energy Efficient Datacentres Next-generation solutions from Nexans Data centre managers face common challenges - to keep information flowing reliability, to plan for future migration and to manage energy consumption. Nexans can help meet these challenges with reliable infrastructure solutions which offer a migration path to 40G whilst delivering the maximum potential for energy efficiency. Nexans Cabling Solutions Alsembergsesteenweg 2, b3 B - 1501 Buizingen Tel: +32 2 363 38 00 • [email protected] www.nexans.com/LANsystems With Environmental Monitoring and Access Control (EMAC) and LANsense Intelligent Infrastructure Management, Nexans offer complete infrastructure solutions for data centres. Global expert in cables and cabling systems Table of content Nexans 7 Symbols 8 LANsystems Introduction 9 LAN Cabling Systems 20 Copper 21 Category 5e 22 LANmark-5 Cable 23 LANmark-5 Snap-In connector 26 LANmark-5 Patch Panels 28 LANmark-5 Outlet 45x45 30 LANmark-5 UniBoot Patch Cords 32 Essential Cat 5e Cable 35 Essential Snap-In Connector 38 Essential-5 Keystone Connector 40 Essential Patch Panels 42 Essential Outlet Modules 44 Essential Cat 5e Patch Cords 46 Category 6 / 6A 48 LANmark-6 Cable 49 LANmark-6 Snap-In Connector 52 LANmark-6 UniBoot Patch Cords 54 LANmark-6 10G UniBoot Patch Cords 56 LANmark-6 10G Snap-In Connector 58 LANmark-6A Cable 61 LANmark-6A Connector 63 LANmark-6A Ultim UniBoot Patch Cords 66 Essential-6 Cable 69 Essential-6 Keystone Connector 71 Essential-6 Patch Panels 73 Essential-6 Outlet Modules 75 Essential-6 Patch Cords 77 03/12/10 - http://www.nexans.co.uk Page 2 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Category 7 / 7A 80 LANmark-7 Cable 81 LANmark-7 GG45 Connector 83 GG45 8C PCB jack 85 LANmark-7 Patch Cords 87 LANmark-7 Splitter Cords 89 LANmark-7A Cable 91 LANmark-7A GG45 Connector 92 LANmark-7A Patch Cord 95 Modular Patch Panels 97 Modular Patch Panels for Snap-In Connectors 98 Empty Patch Panels for Keystone Connectors 100 Modular Outlets 102 European Mounting Hardware for LANmark 103 UK Mounting Hardware for Essential 104 UK Mounting Hardware for LANmark 106 US Mounting Hardware for LANmark 108 3rd Party Party Compatible Mounting Hardware 110 European Mounting Hardware for Essential Keystone 112 US Mounting Hardware for Essential 114 Voice grade 116 Voice Cables 117 IDC connectivity and accessories 119 Voice Patch Panels 121 Voice Patch Cords 123 Tools & Accessories 125 Tools 126 Keystone Clips 128 Retrot Hoods 130 Pre-terminated Copper 132 LANmark Pre-Term Bundles 133 LANmark Pre-Term Units 135 LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack 137 03/12/10 - http://www.nexans.co.uk Page 3 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Optical Fibre 141 Fibre Cables 142 Optical cable specications 143 LANmark-OF Tight Buffer Indoor 146 LANmark-OF Tight Buffer Universal 149 LANmark-OF Micro-Bundle Indoor 151 LANmark-OF Micro-Bundle Universal (24F-72F) 154 LANmark-OF Micro-Bundle Universal (4F-12F) 157 LANmark-OF UD PE 159 LANmark-OF UC PE 162 LANmark-OF UC LSZH 164 Cables - LANmark-OF ZC LSZH 166 Fibre Connectors & Connector Accessories 168 LANmark-OF Connectors 169 Connector Tools & Accessories 170 Pre-Terminated Fibre Assemblies LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly MPO System 172 173 177 LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2, OM3 and OM4 179 LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2), OM3 and OM4 182 LANmark-OF Plug&Play Patch Panels 185 LANmark-OF [email protected] Module 186 Fibre Patch Panels 188 LANmark-OF Sliding Patch Panels 189 LANmark-OF Sliding Preloaded Patch Panels 191 Essential-OF Fixed Patch Panel 194 Outlets 196 LANmark-OF Zone Distribution box 197 Structural Hardware 199 Patch Cords 201 LANmark-OF Patch Cords Pigtails & Splicing Materials 202 207 LANmark-OF Splicing Accessories with Aluminium Protectors Preloaded Sliding Panel 03/12/10 - http://www.nexans.co.uk 208 Page 4 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANmark-OF Splicing Accessories with Aluminium Protectors Snap-In Panel 211 LANmark-OF Splicing Accessories with Heatshrink Protectors Preloaded Sliding Panel 214 LANmark-OF Splicing Accessories with Heatshrink Protectors Snap-In Patch Panel 217 Splicing Materials & Accessories 220 LANmark-OF Pigtails Maxistrip 222 LANmark-OF Pigtails Tight Buffer 224 Adaptors 226 LANmark-OF Snap-In Adapter 227 Standard Adaptors 229 Tools & Accessories 231 LANmark-OF Cleaning Tools 232 LANmark-OF Fibre Accessories 233 Intelligent Infrastructure Management 235 LANsense Software 236 LANsense EMAC Products 237 LANsense Copper Patch Panels 240 LANsense Copper Patch Cords 242 LANsense Fibre Patch Panels 244 LANsense Fibre Patch Cords 246 LANsense Analysers 248 LANsense Next Generation Analyser 250 LANsense I/O and Master/Link cables 252 LANsense Integration Strips 254 Industrial LAN & Harsh Environments 255 LANmark Industry Copper cables 256 LANmark Industry Optical Fibre cables 258 LANmark Industry DIN-Rail Outlets and boxes 260 LANmark Industry IP65/67 outlets 261 LANmark Industry patch cord RJ45 IP67/IP20 Cat.6 263 General Accessories & Cabinets 265 Datacenter racks and frames 266 Patch Guides, Blank Panels & Cable Management 268 LANmark Zone Distribution Boxes 270 03/12/10 - http://www.nexans.co.uk Page 5 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Cabinets - Quick Mount 272 Cabinets - Wall Mountable 274 Cabinet Accessories 276 Miscellaneous Accessories 278 Software, Training, & Services 280 Warranty Services 281 Network Design Tools 282 Training Services 284 03/12/10 - http://www.nexans.co.uk Page 6 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Nexans Nexans is the worldwide leader in the cable industry With energy as the basis of its development, Nexans is a global player in the infrastructure, industry, building and Local Area Network (LAN) markets. As a worldwide leader in the cable industry, it offers an extensive range of cables and cabling systems to raise industrial productivity, improve business performance, enhance security, enrich the quality of life, and assure long-term network reliability. With an industrial presence in 39 countries and commercial activities worldwide, Nexans employs 22,700 people and had sales in 2009 of 5 billion euros. Nexans is listed on NYSE Euronext Paris, compartment A. More information on www.nexans.co.uk Infrastructure Nexans provides complete cables and cabling solutions for power transmission and distribution. New technologies, which are environmentally-friendly, increase capacity and reduce the danger of blackouts. To reinforce rail safety and efciency, we have products especially designed for the demanding railroad environment. And to meet diverse needs of incumbent and new telecoms operators, Nexans has customized solutions aimed at lowering capital expenditure and operating costs. For the world’s busy airports, we offer cables and cabling systems for energy and communication networks, terminals, baggage handling systems, runway lights, control towers, etc. Industry Nexans offers a complete portfolio of cables and solutions for market segments as diverse as the automotive, rolling stock and aerospace industries, shipbuilding, nuclear power, oil & gas and petrochemicals, medical and wind applications, material handling and automation. We add value through advanced technologies and durable high-performance products. Building Nexans supplies cables and network solutions for structures of all types: from small residences to public and ofce buildings and big industrial complexes. Nexans pioneered fire-performance cables for public safety, created industrial Ethernet solutions to unite the ofce and the factory oor platform, and ensured the highest standards of environmental friendliness and recyclability. From standard products to renewable energy solutions, these products contribute to the substainable buildings of the future. Local Area Networks Nexans provides copper and optical ber cabling systems for new resource-intensive applications, like Data Centers, Security services, and Storage Area Networks. Nexans’ advanced solutions are handling core business data, protecting operations in sensitive conditions, and giving organizations highspeed transmission and the ability to protect and retrieve vital information. 03/12/10 - http://www.nexans.co.uk Page 7 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Symbols Minimum dynamic operating bending radius Operating temperature, range RoHS conform Storage temperature, range Ambient installation temperature, range Fire retardant Mechanical resistance to impacts Flame retardant Minimum static operating bending radius 03/12/10 - http://www.nexans.co.uk Page 8 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANsystems Introduction Introduction Modern structured cabling systems for Local Area Networks (LANs) are in demand wherever data is stored, shared or transferred. LAN cabling systems are considered permanent infrastructure of single or multiple buildings, and therefore must comply with current standards regarding system architecture and channel bandwidth, as well as installation. LAN system connections are arranged using modern high-capacity components, and designed to be adaptable to meet today’s bandwidth needs as well as evolving, higher bandwidth applications of the future. Also, LAN topology and architecture should be sufciently exible to easily support the ongoing movement of employees and entire departments. LAN system needs explained LANs need to provide the following benets: • high capacity communication lines to facilitate a rapid response to growth in a company’s data requirements; growth; • ability to support a wide range of network applications, depending on the System Class, by using standards for data transfer, channel length and connection interfaces; • well-developed and exible architecture allowing various network congurations to support new LAN equipment; • ability to increase the number of nodes using the cabling system’s reserves planned for at the design stage; • reliability offered by resilient backbones, which allow bypassing of damaged network segments; • high performance, allowing long-term use of the system with easy migration paths How Nexans addresses LAN needs Nexans Cabling Solutions (NCS) provides exceptional infrastructure design, products, maintenance and support for LANs worldwide. Nexans’ products set the standards in their class. The company constantly improves its products and technologies at its own research facility, aided by professionals in the eld of data transfer systems and solutions. Every Nexans’ LAN component meets all current standards, yet at the same time, are unique creations in design, features and customer advantages. The company is among the world leaders in the telecommunications equipment market. Automated assembly processes for the most sensitive cable communication equipment ensure high quality installation. And superior line and channel properties help ensure a level of reliability exemplied by a 25-year warranty on applications and component quality. Ofcial Certied System Partners also offer a highly competitive labour-cost warranty. LAN Standards International LAN standards One of the principal international documents dening LANs is ISO/IEC 11801. This is a joint standard by the International Standards Organisation (ISO) and the International Electrotechnical Commission (IEC),. ISO/IEC 11801 sets a standard for structured cabling systems installed in customers’ buildings and premises. The requirements apply primarily to administrative or commercial structures. In modern ofce facilities, however, it is typical to exchange data with a warehouse or production facility, and the recommendations in ISO/IEC 11801 cover such applications as well. The standard denes the main characteristics of cabling systems including its architecture, cables and connectors, cable parameters, as well as the length and bandwidth of links and channels. In order to understand the principles of selecting and using cabling systems for transferring data, voice, video or any other information, it is important to read the standards and recommendations in the September, 2002, edition of ISO/IEC 11801, as well as the amendments of 2010. This section provides a brief overview of these requirements as applied to the products in this catalogue. LAN Topology and Architecture The basis of LAN topology is depicted by the master-slave star architecture, also known as ‘tree’ topology. Junctions in such architecture are the distributors, and connecting and/or switching equipment supporting various distribution roles. 03/12/10 - http://www.nexans.co.uk Page 9 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Fig. 1. Hierarchy of a typical LAN cabling system. CD – Campus Distributor BD - Building Distributor FD – Floor Distributor CP – Consolidation Point TO – Telecommunications Outlet Structured cabling connects switches, , computers and increasingly, devices like telephones and IP cameras. LANs should therefore have a high degree of exibility to support widely diverse connections as well as the ability to respond promptly to changeable requirements for the physical channel conguration. Distributors Patch panels are mounted on racks or in cabinets, and can also be installed beneath oors or behind walls. Normally, the cabinets also house power supply units and various accessories facilitating labels and administration. The cabling system distributors are usually installed in separate technical rooms. A LAN serving a multi-storey building may have split backbones, each one independent but still forming a star hierarchy. Should the need arise, its communication lines can be directly connected to another backbone. It is possible to reduce the number of backbone links and distributors depending on available space and the number of users. Certain distributors of various levels can also be combined into one. In order to improve the system’s reliability, distributors of one level, together with connected lines, can be replicated in various parts of the building. In this case, the user’s telecommunication outlets will be connected to separate distributors. 03/12/10 - http://www.nexans.co.uk Page 10 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Fig. 2. Hierarchy of a typical LAN cabling system. BD1,2 - Building Distributor FD1,2 – Floor Distributor TO – Telecommunications Outlet In cases where two or more buildings are connected using a single cabling infrastructure, the LAN will have three sections: campus backbone, building backbone, and horizontal cabling (Fig.3). Fig. 3. Hierarchy of a typical LAN cabling system. CD – Campus Distributor BD - Building Distributor FD – Floor Distributor CP – Consolidation Point TO – Telecommunications Outlet TE – Terminal Equipment 03/12/10 - http://www.nexans.co.uk Page 11 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Backbones The Campus backbone connects the Campus distributor with the Building distributors through panels and switches, to which the cables are connected; and patch cords or jumpers. ISO/IEC 11801 provides for entry points to the backbone which facilitate the entry and termination of cables inside the building. These include cables supporting telephone, Internet, cable TV, or technical monitoring systems. The campus distributor can be housed in the same structure as the building distributor, or even in the same technical room as the oor distributor. Such technical rooms are called equipment rooms, and its respective requirements are set out by ISO/IEC TR 14763-2 (Fig.4). The building (or vertical) backbone connects separate oor distributors to the building distributor. The building backbone consists of internal trunk cables, patch panels and patch cords for connections within the building distributor. Horizontal cabling (or oor-by-oor distribution)) connects the oor distributor with desktop or telecommunication outlets (TO’s). A consolidation point can also be part of the horizontal cabling in cases of zonal distribution. Fig. 4. Location of distributors in a typical cabling system within a building. CD- Campus Distributor BD – Building Distributor FD – Floor Distributor CP – Consolidation Point TO – Telecommunication Outlet ER – Equipment Room BEF – Building Entrance Facility Cross- and direct-connect explained The connection between active equipment and backbone or horizontal cables can be build with a degree of exibility. The most exible solution is the cross-connect (see Fig.5). In addition to improving system administration, this solution allows the splitting of specialists’ areas of responsibility and facilitates equipment maintenance. However, adding connectors to the communication channel can impair its characteristics. The alternative to a cross-connect is an interconnect (Fig.6 - next page.) 03/12/10 - http://www.nexans.co.uk Page 12 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Fig. 5. Example of cross-connect type TE – Telecommunications Equipment PP – Patch Panel EC – Equipment Cord PC – Patch Cord In addition to backbones, the standard species connections to the desktop or Work Area. ISO/IEC TR 14763-2 requires up to 10m2 for the Work Area, i.e. where the end-user equipment is connected to the telecommunication outlets. In certain cases, the Work Area can be organised more compactly, providing 4-6 m2 per user. According to ISO/IEC 11801, at least two telecommunication outlets must be provided for each user. Fig. 6. Example of interconnect type TE – Telecommunications Equipment PP – Patch Panel EC – Equipment Cord PC – Patch Cord The number of Floor Distributors (FD) depends on the area to be covered or the number of workplaces per area. Generally, the standard recommends at least one FD for every 1 000 m2 of ofce area. 03/12/10 - http://www.nexans.co.uk Page 13 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. The physical length of a horizontal copper channel is maximized to 100 m. The total length of sections including backbones should not exceed 2 000 m. Designing LANs for high speed Supporting high speed protocols such as Fast Ethernet, 100Base-TX and Gigabit Ethernet 1000Base-T requires a minimum of Class D performance. In order to meet Class D requirements, the components of Cat. 5e cabling should adhere to specications of the second edition of the ISO/IEC 11801 standard, issued in 2002. As an alternative, installing Class E, Ea, F and Fa systems within a horizontal cabling are permissible: these require components of Cat. 6, 6A, 7 and 7A respectively. These solutions provide a high bandwidth reserve for future applications. Nexans Cabling Solutions offers LANmark-5, 6, 6A , 7 and 7A systems. Detailed product information for these systems can be found in this catalogue’s respective sections. Fig. 7. The use of transfer medium in a typical LAN cabling system. CD – Campus Distributor BD – Building Distributor FD – Floor Distributor CP – Consolidation Point TO – Telecommunication Outlet TE – Terminal Equipment OE EQP – Opto-electronic equipment 03/12/10 - http://www.nexans.co.uk Page 14 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. The most important general requirements of ISO/IEC 11801:2002 for twisted pair media are: • Cables used for Class D, E, Ea, F and Fa systems must have rated characteristic impedance of 100 Ohms; • Connectors at the ‘TO’ side must correspond to connector standard RJ45 (IEC 60603-7) for Cat. 5e, 6 and 6A, and to connector standard GG45 (IEC 60603-7-7) for Cat. 7 and 7A. Fibre optic cabling applications The standard recommends bre optic cable for campus -and building backbones. Its’ low signal attenuation, immunity to electromagnetic disturbances and galvanic seperation between buildings make bre a strong alternative. The core of bre optic cables, can be produced from multi-mode (MM) bres sized 50/125 mm and 62.5/125 mm with graded index prole, and single-mode (SM) bres sized 9/125 mm with step index prole. Detailed information on Nexans bre optic cable specications is in the section “LANmark-OF Optical Systems”. The standard further recommends the SC- and LC-connectivity as the optical bre connector interface for all LAN backbones. However, if a higher concentration of connections is required, the standard permits Small Form Factor connectors (SFF) which requires LC connectors. Design Considerations Layouts of Horizontal Channels The standard allows the use of four channel types within a horizontal distribution to connect user equipment as well as network telecom equipment (see structure below.) The simplest channel type is shown in Layout A (Fig. 8). The most exible and complex channel type in a horizontal distribution is shown in Layout D. Horizontal channel links have the following limitations: • Physical length of the channel must not exceed 100 m; • Physical length of horizontal cable used to build a communication line must not exceed 90 m, depending on the total length of patch cords; • If total length of patch and equipment cords exceeds 10 m, the length of the horizontal cable must be proportionally reduced according to the algorithm detailed in the standard; • When using a Consolidation Point (CP) for zonal distribution, it must be installed at least 15 m from the Floor Distributor (FD). Besides these limitations, the following recommendations for the horizontal backbone should be noted: • When using a Multi-User Telecommunication Outlet (MUTO), the length of the equipment cord connecting the terminal equipment should not exceed 20 m; • Recommended length of patch cords is up to 5 m. These recommendations allow the use of longer cords should the need arise. 03/12/10 - http://www.nexans.co.uk Page 15 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Layout A: Interconnect-TO type Layout B: Crossconnect-TO type 03/12/10 - http://www.nexans.co.uk Page 16 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Layout C: Interconnect-CP-TO type Layout D: Crossconnect-CP-TO type Fig. 8. Possible layouts of horizontal backbone channels BD – Building Distributors FD – Floor Distributor CP – Consolidation Point TO – Telecommunication Outlet TE – Terminal Equipment PC – Patch Cord EC – Equipment Cord CC – Consolidation Point Cable 03/12/10 - http://www.nexans.co.uk Page 17 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. If a twisted pair based system is used, the most complex and exible layout is a 4-connector channel (Fig. 9). The principal limitations for Class D, E, Ea, F and Fa backbone communication channels are: • Physical length of the channel must not exceed 100 m; • When using 3 connectors along the channel, the installation or mounting cable must be at least 15 m long. Depending on the total length of patch cords, the mounting cable’s length must be proportionally decreased. To calculate mounting cable length, remember to account for patch and equipment cord length, as well as the category of components and the required channel class. ISO/IEC 11801 provides calculation algorithms Fig. 9. Typical layout of communication backbone channel. CD – Campus Distributor BD – Building Distributor FD – Floor Distributor PP – Patch Panel EQP – Equipment Layouts of Fibre Optic-Based Channels Due to low signal attenuation when using bre optics, it is possible to connect the communication lines of different backbones in a single transmission channel. The following types of combined bre channels are possible: • Patched channel allowing cross-connection of lines belonging to different, adjoining backbones (Fig. 10); • Collapsed backbone model creating a direct link between BD and TO limited to a distance of 300m and only with MM bre. 03/12/10 - http://www.nexans.co.uk Page 18 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Fig. 10. Patched combined channel layout. BD – Building Distributors FD – Floor Distributor PP – Patch Panel TO – Telecommunication Outlet EQP - Equipment CC - Consolidation Point Cable TE - Terminal Equipment 03/12/10 - http://www.nexans.co.uk Page 19 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LAN Cabling Systems Nexans provide a full range of LAN cabling solutions & services. • LANsense : Intelligent Infrastructure Management (IIM) including EMAC Environmental Monitoring & Access Control • LANmark : Passive LAN infrastructure solutions • essential: component based cabling products • Software, Services & Support Tools Please see the link to LAN Systems Main webpages for support documentation and tools. 03/12/10 - http://www.nexans.co.uk Page 20 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Copper Nexans offer the full range of copper LAN systems to ensure we can provide the solution most suited for your needs. • • • • All performance levels: Cat 5e, Cat 6, Cat 7 & voice grade All construction types : UTP, FTP, S-FTP, PiMF Modular connectivity based on 'Snap-in' and '808' connectivity Guaranteed Application support with extended distance 03/12/10 - http://www.nexans.co.uk Page 21 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Category 5e Nexans offer a choice of Category 5e ranges: Full System Offer LANmark-5 • Cat 5e system based on snap-in format connectivity LANconnect-5 • Cat 5e system based on 808 style connectivity. Extended distance support is possible using 'LANconnect PLUS' cables. All complete systems offer a comprehensive Certied System Parts & LABOUR Warranty. Component based solution Essential - component based 'economy without compromise' • cost effective solution for basic installations • instant downloadable Nexans Link Certicate. 03/12/10 - http://www.nexans.co.uk Page 22 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Cable • Offers headroom to Category 5e standards • Performance guaranteed to 155MHz • Supports Gigabit Ethernet Description Application Nexans LANconnect/LANmark-5 cable is designed to provide additional performance and bandwidth over and above the basic requirements of Category 5e. With modern high speed applications, installation effects can have a serious inuence on the initial cable performance and therefore without sufcient headroom, problems can arise. The addition of transition points within the link can also lead to additional losses. Nexans LANconnect/LANmark-5 provides the additional headroom necessary to ensure that applications such as Gigabit Ethernet can run efciently after installation. It is available in Grey PVC or Orange LSZH. Performance With guaranteed performance to 155MHz, Nexans LANconnect/LANmark-5 cables provide guaranteed additional headroom and bandwidth over and above the requirements of TIA 568-B and IEC 61156-5. Guarantees Nexans LANconnect/LANmark-5 cables are covered by the guarantee that they are Category 5e and by a parts and labour warranty as described in the Nexans Certied System Warranty. Moreover they come with following guarantees: • • • • • 3dB min. headroom over IEC 61156-5 and TIA 568-B Cat 5e NEXT Improved ACR Superior EMC performance 155MHz guaranteed performance When used in a full LANmark system, full LANmark D channel warranty can be obtained. Standards International ISO/IEC 11801; ISO/ IEC 61156-5 National TIA/EIA-568-B.2 RoHS conform Yes 03/12/10 - http://www.nexans.co.uk Page 23 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Cable Characteristics Electrical characteristics Transfer impedance Characteristic impedance Transmission characteristics Propagation delay, max. 100 MHz Usage characteristics Range RoHS conform Product List Nexans ref. N100.403 N100.413 N100.402 N100.421 N100.412 N100.431 N100.493 N100.443 N100.492 N100.491 N100.494 N100.442 N100.441 N100.444 N100.502 N100.507 N100.521 N100.512 N100.517 N100.522 20 100 Ohm 536 ns/100m LANmark-5 Yes Name LANconnect/LANmark-5 F²/UTP Dual LSZH 500m Reel LANconnect/LANmark-5 F²/UTP Dual PVC 500m Reel LANconnect/LANmark-5 F²/UTP LSZH 1000m Reel LANconnect/LANmark-5 F²/UTP LSZH 500m Reel LANconnect/LANmark-5 F²/UTP PVC 1000m Reel LANconnect/LANmark-5 F²/UTP PVC 500m Reel LANconnect/LANmark-5 F¹/UTP Dual LSZH 500m Reel LANconnect/LANmark-5 F¹/UTP Dual PVC 500m Reel LANconnect/LANmark-5 F¹/UTP LSZH 1000m Reel LANconnect/LANmark-5 F¹/UTP LSZH 305m Box LANconnect/LANmark-5 F¹/UTP LSZH 500m Reel LANconnect/LANmark-5 F¹/UTP PVC 1000m Reel LANconnect/LANmark-5 F¹/UTP PVC 305m Box LANconnect/LANmark-5 F¹/UTP PVC 500m Reel LANconnect/LANmark-5 U/UTP LSZH 1000m Reel LANconnect/LANmark-5 U/UTP LSZH 305m Box LANconnect/LANmark-5 U/UTP LSZH 500m Reel LANconnect/LANmark-5 U/UTP PVC 1000m Reel LANconnect/LANmark-5 U/UTP PVC 305m Box LANconnect/LANmark-5 U/UTP PVC 500m Reel Type of cable F²TP Shotgun F²TP Shotgun =Make to order, Category Outer sheath =Make to stock Flame retardant Cat. 5e LSZH IEC 60332-1 Cat. 5e PVC IEC 60332-1 F²TP Cat. 5e LSZH IEC 60332-1 F²TP Cat. 5e LSZH IEC 60332-1 F²TP Cat. 5e PVC IEC 60332-1 F²TP F/UTP Shotgun F/UTP Shotgun Cat. 5e PVC IEC 60332-1 Cat. 5e LSZH IEC 60332-1 Cat. 5e PVC IEC 60332-1 F/UTP Cat. 5e LSZH IEC 60332-1 F/UTP Cat. 5e LSZH IEC 60332-1 F/UTP Cat. 5e LSZH IEC 60332-1 F/UTP Cat. 5e PVC IEC 60332-1 F/UTP F/UTP Cat. 5e Cat. 5e PVC PVC IEC 60332-1 IEC 60332-1 U/UTP Cat. 5e LSZH IEC 60332-1 U/UTP Cat. 5e LSZH IEC 60332-1 U/UTP Cat. 5e LSZH IEC 60332-1 U/UTP Cat. 5e PVC IEC 60332-1 U/UTP U/UTP Cat. 5e Cat. 5e PVC PVC IEC 60332-1 IEC 60332-1 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 24 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Cable Electrical Performance all values are specied at 20°C Frequency Attenuation dB/100m NEXT dB ACR dB/100m PSNEXT(*) dB ELFEXT dB/100m PSELFEXT dB/100m RL dB 1 2.1 68.3 66.2 65.3 63.8 61.0 20.0 4 4.0 59.3 55.3 56.3 51.7 49.0 23.0 10 6.3 53.3 47.0 50.3 43.8 41.0 25.0 16 8.0 50.3 42.3 47.3 39.7 36.9 25.0 20 9.0 48.8 39.8 45.8 37.7 35.0 25.0 31.25 11.4 45.9 34.5 42.9 33.9 31.1 23.6 62.5 16.5 41.4 24.9 38.4 27.9 25.1 21.5 100 21.3 38.3 17.0 35.3 23.8 21.0 20.1 155 27.2 35.5 8.3 32.5 19.9 17.2 18.7 (*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the relevant TIA and IEC cable standards. Selling delivery information Installation: Nexans LANconnect/LANmark-5 cables are designed to be installer friendly. The additional performance headroom provides condence for difcult installations. 03/12/10 - http://www.nexans.co.uk Page 25 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Snap-In connector • • • • • • Available in Screened and Unscreened version Version for stranded wire available, both in Screened and Unscreened No punchdown tool needed for termination Reduced risk of installation errors gives consistent performance Compatible with all Snap-in hardware Compatible with keystone format using additional clip Description Application The LANmark-5 Snap-in connector range is part of the Nexans modular system and ts in all structural hardware designed for this range. As such it supports all data applications dened for Cat 5 and Cat 5e, such as 10baseT, Fast Ethernet, Gigabit Ethernet, 155 ATM. Performance The LANmark-5 Snap-in connector is designed to reach the highest performance in Cat5e. It has outstanding performance for attenuation (insertion loss), NEXT/ FEXT, Power Sum NEXT/FEXT and Return Loss, exceeding the Cat 5e connector specs as in ISO/IEC 11801:2002. Used with Nexans LANmark-5 cable and patchcords, the connector is tested to exceed the link and stringent fourconnector channel requirements as dened in the ISO/IEC 11801:2002 standard. Guarantees The LANmark-5 Snap-in connector range is covered by the Nexans guarantee conform The General Terms and Conditions of Sales. In combination with the Nexans LANmark-5 product range, the Nexans Certied System Warranty can be obtained, covering parts, system and labour. Standards Installation International ISO/IEC 11801 The LANmark-5 Snap-in connector range is designed to be terminated by hand, without punchdown tool. The exclusive construction of the wire organizer makes termination fast and self-evident. To allow an even quicker and easier installation, an optional comfort tool can be used (N420.567). This tool includes an extraction mechanism which makes the connector re-usable. The LANmark-5 snap-in range is Nexans technology inside and user friendly outside. National TIA/EIA-568-B.2 • • • • • • Fast and easy termination thanks to wire organiser No punchdown tool needed Colour code : T568A and T568B Re-usable with universal comfort tool (N420.567) Fits in all Nexans structural hardware for snap-in format Different versions available: for solid wire and for stranded wire, both in screened and unscreened version. 03/12/10 - http://www.nexans.co.uk Page 26 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Snap-In connector Characteristics Construction characteristics Connector type Dimensional characteristics Width Usage characteristics Range Product List Nexans ref. N420.555 N420.556 N420.550 N420.551 RJ45 and Tool-less IDC 17 mm LANmark-5 Name LANmark-5 Screened Snap-In connector LANmark-5 Screened Snap-In connector for stranded wire LANmark-5 Unscreened Snap-In connector LANmark-5 Unscreened Snap-In connector for stranded wire =Make to order, =Make to stock Height (mm) Screen 23.2 Yes 23.2 Yes 22.9 No 22.9 No = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 27 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Patch Panels • • • • • • • Offers headroom to latest Category 5e standard Sliding mechanism version: easy access from front side and including marking strip Top connection version supplied with an integrated cabel management plate for tie wrap LSA+/110 IDC compatible termination included marking strip Screened and unscreened version Suitable for 4 twisted pairs LAN cable and for Voice multipairs cable : access from rear or from side Description Application The LANmark-5 1HU twisted pair patch panel is based on 19" frame dimensions. In the sliding mechanism version, it is easy to manage thanks to the integrated Clip-on. In the top connection version, it is easy to manage thanks to the integrated cable management plate. Both versions provide reliable cable retention and grounding. The use of patch guides (sold separately) allows an orderly arrangement of patchcords. Performance The LANmark-5 connector has been designed to reach the highest in Cat 5E performance. It has outstanding performances for attenuation (insertion loss), NEXT/FEXT per pair, Power Sum NEXT/FEXT and RETURN LOSS. The LANmark-5 connector module is independently tested and when used with LANmark-5 cable and patchcords, the 4 connector channel exceeds the Class D requirements as dened in the ISO/IEC11801 : 2002 Guarantees The LANmark-5 PCB patch panel is fully compliant with the ISO/IEC11801 : 2002 and exceeds all parameters with large headroom. In combination with the Nexans LANmark product range, this patch panel offers you a full Class D warranted solution. Standards International ISO/IEC 11801 Installation The patch panel is equipped with a sliding mechanism or with an integrated cable management plate for easy front access when mounted into a cabinet. This time saving mechanism facilitates front side termination. • • • • • • Easy to install and modify: all operations are performed at the front side. Supplied with xings. Available with Nexans LSA+/110 IDC compatible terminations. Unscreened and screened versions available. Suitable for multipairs cable 9 pins IDC block for easy termination of drain wire for screened version or 8 pins IDC block for unscreened version • Colour code T568A and T568B. • Can be used with all types of cables : F2TP, UTP, S-FTP and STP. • Accepts 24, 23 and 22 AWG cables. 03/12/10 - http://www.nexans.co.uk Page 28 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Patch Panels Characteristics Dimensional characteristics Heightunit Usage characteristics Category Range Number of ports Product List Nexans ref. N500.115 N500.215 N500.205 N500.105 1U Cat. 5e LANmark-5 24 Name LANmark 5 Sliding PCB Patch Panel Screened LANmark-5 Fixed PCB Patch Panel Screened LANmark-5 Fixed PCB Patch Panel Unscreened LANmark-5 Sliding PCB Patch Panel Unscreened Screen Yes Yes No No = Make to order, 03/12/10 - http://www.nexans.co.uk Depth (mm) 170 137 137 170 = Make to stock Page 29 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Outlet 45x45 • • • • • Offers headroom to latest Category 5e standard. LSA+ termination Screened and unscreened version Single and double connection available Fits in Nexans structural hardware. Description Features Full Category 5 outlets with better than 40 dB NEXT at 100 MHz between every pair combination. RJ45 ISO 8877 compliant outlets with T 568B and T 568A pin conguration. Fast Foolproof installation: • IDC contacts at frontside for convenient installation • IDC colour coding in conformity with cable colour coding Integrated Outlet Labelling System for easy management and identication • Labelling window supplied Versions available: single and double RJ45 connectors, screened and unscreened. Country specic covering plates adapt to national requirements and designs. The connector module is designed to be compatible with any covering plate by using adaptation rings if required. These modules t into a complete range of international Covering Plates. Standards All plastic material is UL 94V0. International ISO/IEC 11801 Values Min. Next Loss (dB) Min. Return Loss (dB) 40 14 03/12/10 - http://www.nexans.co.uk Page 30 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 Outlet 45x45 Characteristics Construction characteristics Connector type Dimensional characteristics External dimensions Transmission characteristics Attenuation, max. 100 MHz Usage characteristics Range Product List Nexans ref. N462.211 N462.210 N462.201 N462.200 N462.111 N462.110 N462.101 N462.100 RJ45 and LSA+ IDC 45 (H)x 45 (W) x 16(D)mm 0.40 dB/100m LANmark-5 Name LANmark-5 Double Outlet 45x45 Screened Ivory with Shutter LANmark-5 Double Outlet 45x45 Screened White with Shutter LANmark-5 Double Outlet 45x45 Unscreened Ivory with Shutter LANmark-5 Double Outlet 45x45 Unscreened White with Shutter LANmark-5 Single Outlet 45x45 Screened Ivory with Shutter LANmark-5 Single Outlet 45x45 Screened White with Shutter LANmark-5 Single Outlet 45x45 Unscreened Ivory with Shutter LANmark-5 Single Outlet 45x45 Unscreened White with Shutter =Make to order, =Make to stock Colour Screen Ivory No White RAL 9010 Yes Ivory Yes White RAL 9010 No Ivory Yes White RAL 9010 Yes Ivory No White RAL 9010 No = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 31 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 UniBoot Patch Cords • • • • • Complies fully with Category 5 standards Uses Nexans cable technology Fully matched with other components for maximum performance LSZH Flame retardant jacket or PVC Retrot Latch Protector available in 8 colours for colour coding Description Application This full Category 5e patch cord maximises the full performance of the channel and will exceed the requirements of the ISO/IEC 4-connector model, when used as part of a LANmark-5 cabling Class D solution. This provides improved data throughput and allows for the inclusion of a Cross-Connect or Consolidation Points for maximum system exibility. Screened and unscreened versions available. LANmark-5 Patch Cords feature a slim over-moulded boot for mechanical protection, which is kept inside the RJ45 boundaries to enable high density patching with 48 cords in 1 height unit. A ‘Retrotable’ Latch Protector is available as accessory, which can be used for colour coding of different services. Guarantees • When used with the LANmark-5 system, Cat 5e/Class D channel performance complies with the channel limits of TIA/EIA-568B and ISO/IEC 11801: 2002 and a 25 years channel warranty can be obtained. • Reliable connections. Standards International ISO/IEC 11801 National TIA/EIA-568-B.2 Usage • Small cross section allows neat installation and simplies the creation of bundles in cabinets. • Low Smoke Halogen Free - Flame Retardant and PVC jackets are standard. • 1, 2, 3, 5, 10 and 20m are standard lengths available from stock; other lengths are available on demand. • Orange for LSZH and Dark Grey for PVC are standard colours; other colours (Red, Blue, Yellow and Green) are available on request (in PVC only). • Rugged construction. • High connector retention force due to moulded connectors. • External strain relief. • Self-latching, high reliability RJ45 (ISO 8877) connectors. 03/12/10 - http://www.nexans.co.uk Page 32 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 UniBoot Patch Cords Characteristics Dimensional characteristics Nominal outer diameter Electrical characteristics Characteristic impedance Usage characteristics Range Mechanical durability/matings Product List Nexans ref. N115.P1B100OU New N115.P1B010OU New N115.P1B200OU New N115.P1B020OU New N115.P1B030OU New N115.P1B050OU New N115.P2B100DU New N115.P2B010DU New N115.P2B200DU New N115.P2B020DU New N115.P2B030DU New N115.P2B050DU New N115.P1A100OU New N115.P1A010OU New N115.P1A200OU New N115.P1A020OU New N115.P1A030OU New N115.P1A050OU New N115.P2A100DU New N115.P2A010DU New 5.5 mm 100 Ohm LANmark-5 750 =Make to order, Outer Length sheath (m) Name LANmark-5 Patch Cord Cat 5e Screened LSZH 10m Orange LANmark-5 Patch Cord Cat 5e Screened LSZH 1m Orange LANmark-5 Patch Cord Cat 5e Screened LSZH 20m Orange LANmark-5 Patch Cord Cat 5e Screened LSZH 2m Orange LANmark-5 Patch Cord Cat 5e Screened LSZH 3m Orange LANmark-5 Patch Cord Cat 5e Screened LSZH 5m Orange LANmark-5 Patch Cord Cat 5e Screened PVC 10m Grey =Make to stock Colour Screen LSZH 10 Orange Yes LSZH 1 Orange Yes LSZH 20 Orange Yes LSZH 2 Orange Yes LSZH 3 Orange Yes LSZH 5 Orange Yes PVC 10 Grey Yes LANmark-5 Patch Cord Cat 5e Screened PVC 1m Grey PVC 1 Grey Yes LANmark-5 Patch Cord Cat 5e Screened PVC 20m Grey PVC 20 Grey Yes LANmark-5 Patch Cord Cat 5e Screened PVC 2m Grey PVC 2 Grey Yes LANmark-5 Patch Cord Cat 5e Screened PVC 3m Grey PVC 3 Grey Yes LANmark-5 Patch Cord Cat 5e Screened PVC 5m Grey PVC 5 Grey Yes LSZH 10 Orange No LSZH 1 Orange No LSZH 20 Orange No LSZH 2 Orange No LSZH 3 Orange No LSZH 5 Orange No PVC 10 Grey No PVC 1 Grey No LANmark-5 Patch Cord Cat 5e Unscreened LSZH 10m Orange LANmark-5 Patch Cord Cat 5e Unscreened LSZH 1m Orange LANmark-5 Patch Cord Cat 5e Unscreened LSZH 20m Orange LANmark-5 Patch Cord Cat 5e Unscreened LSZH 2m Orange LANmark-5 Patch Cord Cat 5e Unscreened LSZH 3m Orange LANmark-5 Patch Cord Cat 5e Unscreened LSZH 5m Orange LANmark-5 Patch Cord Cat 5e Unscreened PVC 10m Grey LANmark-5 Patch Cord Cat 5e Unscreened PVC 1m Grey = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 33 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-5 UniBoot Patch Cords Nexans ref. Name N115.P2A200DU New N115.P2A020DU New N115.P2A030DU New N115.P2A050DU New LANmark-5 Patch Cord Cat 5e Unscreened PVC 20m Grey LANmark-5 Patch Cord Cat 5e Unscreened PVC 2m Grey LANmark-5 Patch Cord Cat 5e Unscreened PVC 3m Grey LANmark-5 Patch Cord Cat 5e Unscreened PVC 5m Grey Outer sheath Length (m) PVC 20 Grey No PVC 2 Grey No PVC 3 Grey No PVC 5 Grey No = Make to order, 03/12/10 - http://www.nexans.co.uk Colour Screen = Make to stock Page 34 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Cat 5e Cable • • • • • U/UTP, F/UTP & SF/UTP construction Complies to latest Cat 5E standards Supports Gigabit Ethernet Guaranteed performance to 100MHz Single foil offers EMC performance Description Application Category 5e cables are the standard 100MHz offering from Nexans. Manufactured in accordance with TIA 568-B and IEC 61156-5, they are suitable for basic voice & data installations. Available in Light Grey PVC or Orange LSZH. Performance Nexans Category 5e cables are compliant with the requirements of the TIA 568-B and IEC 61156-5. Standards International ISO/IEC 11801 National TIA/EIA-568-B.2 03/12/10 - http://www.nexans.co.uk Page 35 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Cat 5e Cable Characteristics Usage characteristics Range Product List Nexans ref. N100.453 N100.463 N100.452 N100.454 N100.451 N100.462 N100.464 N100.461 N100.410 N100.420 N100.407 N100.471 N100.417 N100.476 N100.552 N100.554 N100.551 N100.562 N100.564 N100.561 essential Name Type of cable Essential F/UTP Cat 5e 0,5MM Dual LSZH 500M REEL Essential F/UTP Cat 5e 0,5MM Dual PVC 500M REEL Essential F/UTP Cat 5e 0,5MM LSZH 1000M REEL Essential F/UTP Cat 5e 0,5MM LSZH 500M REEL Essential F/UTP Cat 5e 0,5MM LSZH BOX 305M Essential F/UTP Cat 5e 0,5MM PVC 1000M REEL Essential F/UTP Cat 5e 0,5MM PVC 500M REEL Essential F/UTP Cat 5e 0,5MM PVC BOX 305M Essential SF/UTP Cat 5e 0,5MM DUAL LSZH 500M REEL Essential SF/UTP Cat 5e 0,5MM DUAL PVC 500M REEL Essential SF/UTP Cat 5e 0,5MM LSZH 1000M REEL Essential SF/UTP Cat 5e 0,5MM LSZH 500M REEL Essential SF/UTP Cat 5e 0,5MM PVC 1000M REEL Essential SF/UTP Cat 5e 0,5MM PVC 500M REEL Essential U/UTP Cat 5e 0,5MM LSZH 1000M REEL Essential U/UTP Cat 5e 0,5MM LSZH 500M REEL Essential U/UTP Cat 5e 0,5MM LSZH BOX 305M Essential U/UTP Cat 5e 0,5MM PVC 1000M REEL Essential U/UTP Cat 5e 0,5MM PVC 500M REEL Essential U/UTP Cat 5e 0,5MM PVC Box 305M F/UTP Shotgun F/UTP Shotgun =Make to order, =Make to stock Length Packaging Outer (m) sheath 500 Reel LSZH 500 Reel PVC F/UTP 1000 Reel LSZH F/UTP F/UTP F/UTP F/UTP F/UTP SF/UTP Shotgun SF/UTP Shotgun 500 305 1000 500 305 Reel Box Reel Reel Box LSZH LSZH PVC PVC PVC 500 Reel LSZH 500 Reel PVC SF/UTP 1000 Reel LSZH SF/UTP 500 Reel LSZH SF/UTP 1000 Reel PVC SF/UTP 500 Reel PVC U/UTP 1000 Reel LSZH U/UTP U/UTP U/UTP U/UTP U/UTP 500 305 1000 500 305 Reel Box Reel Reel Box LSZH LSZH PVC PVC PVC = Make to order, = Make to stock Electrical Performance all values are specied at 20°C Frequency Attenuation dB/100m NEXT dB ACR dB/100m PS NEXT (*) dB ELFEXT dB/100m PSELFEXT dB/100m RL dB 4 4.1 56.3 52.2 53.3 51.7 49.0 23.0 10 6.5 50.3 43.8 47.3 43.8 41.0 25.0 16 8.3 47.2 38.9 44.3 39.7 36.9 25.0 20 9.3 45.8 36.5 42.8 37.7 35.0 25.0 31.25 11.7 42.9 31.2 39.9 33.9 31.1 23.6 62.5 17.0 38.4 21.4 35.4 27.9 25.1 21.5 100 22.0 35.3 13.3 32.3 23.8 21.0 20.1 03/12/10 - http://www.nexans.co.uk Page 36 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Cat 5e Cable (*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the relevant TIA and IEC cable standards. 03/12/10 - http://www.nexans.co.uk Page 37 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Snap-In Connector • • • • • • Complies to the latest Category 5e standard Fast termination from side or rear Fits in all Nexans structural hardware 110 and LSA+ termination An adaptor can be added to t the keystone format Unscreened or with EMC rear cover Description Application The Nexans Essential Snap-In connector is part of the Nexans modular system and ts in all structural hardware designed for this range. The Nexans Essential Range of Cat 5e cabling products are compliant with ISO/IEC 11801 : 2002. Installation The Nexans Essential Snap-in connector is a LSA+/110 connector. It is designed to be terminated by hand, using either 110 or LSA+ termination tool. • • • • • • • Advantage: 110 and/or LSA+ termination. Fast termination of cable from side or rear. Colour code: T568A and T568B. A clip can be added to adapt for keystone format. Fits in all Nexans modular structural hardware of Snap-in. Modular patch panel also available. Can be used with all types of cables: U/UTP, F/UTP, F2/UTP ,S/FTP or SF/UTP (24 AWG, 23 AWG). • Can be used with or without an EMC rear cover. • Two positions for the drain wire connection Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 38 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Snap-In Connector Characteristics Construction characteristics Connector type Usage characteristics Range Product List Nexans ref. N420.426 N420.416 RJ45 and 110/LSA+ IDC essential Name Essential Screened Snap-In Cat 5e LSA/110 connectivity Essential Unscreened Snap-In Cat 5e LSA/110 connectivity = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 39 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-5 Keystone Connector • • • • • Complies with the latest Category 5e standards Unscreened Fast termination from either side or rear Fits in all Nexans keystone hardware designed for Essential-5 and -6 110 or LSA+ termination Description Application The Nexans Essential-5 keystone connector is manufactured and tested to the latest Category 5e specications. It supports Class D applications up to 100 MHz. When installed in conjunction with Essential-5 cable and patch panels, a 25 year Class D Link Warranty can be obtained from the Nexans web site. Design The Essential-5 keystone connector is designed to match with Essential-5 cable and patch cords and complements all Essential modular components, such as: • keystone patch panels (black and white) • keystone outlet modules (UK, US and European formats) Please follow the links on this page to view the related datasheets. Standards The modular jack is designed for keystone footprints of 14.78 mm width, 20-20.78 mm height and 1.5 mm wall thickness and is compatible with a variety of keystone formatted structural hardware. (Please check compatibility with Nexans before using 3rd party hardware) International ISO/IEC 11801 Performance The Essential-5 keystone connector is compliant with the specications of ISO/ IEC 11801 and EN 50173. Installation • • • • • Cable entry from either side or rear. Wiring according to colour code T568B or T568A. Termination with 110 or LSA+ punchdown tool. Accepts 24, 23 and 22 AWG solid core cables. Fits Nexans hardware designed for keystone format. 03/12/10 - http://www.nexans.co.uk Page 40 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-5 Keystone Connector Characteristics Construction characteristics Connector type Usage characteristics Range Product List Nexans ref. N420.415 New RJ45 and 110/LSA+ IDC essential Name Essential-5 Keystone Connector Cat 5e Unscreened = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 41 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Patch Panels • Complies to the latest Category 5e standard • Punchdown from the top or the rear side • Unscreened Description Application The Nexans Essential 1HU twisted pair patch panel is based on 19" frame dimensions. It is easy to manage thanks to the cable guide tie wrap support. The use of patch guides (sold separately) allows an orderly arrangement of patch cords. Performance The Nexans Essential Range of Cat 5e cabling products are compliant with ISO/ IEC 11801 :2002. Guarantees • 20 years link certicate available when installed as part of a Nexans Essential system. Installation • • • • Supplied with xings. Unscreened. Colour code T568A and T568B (Product dependent). Can be used with all types of cables : U/UTP, F/UTP, F2/UTP, S/FTP, SF/UTP (23 AWG , 24 AWG). 03/12/10 - http://www.nexans.co.uk Standards International ISO/IEC 11801 Page 42 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Patch Panels Product List Nexans ref. N500.202 N424.510 N424.513 N424.511 =Make to order, =Make to stock Name Essential 24 port PCB Patch Panel Rear Connection 1 HU Unscreened Essential 24 port PCB Patch Panel Rear Connection Black Essential 24 port PCB Patch Panel Top Connection Black Essential 48 port PCB Patch Panel Rear Connection Black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 43 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Outlet Modules • • • • • • Includes 25x50, LJ6C, and triple modules Complies to the latest Category 5e standards Unscreened LSA+ termination UK white Fits in all UK Nexans structural hardware Description Performance The Nexans Essential Range of Cat 5e cabling products are compliant with ISO/ IEC 11801 : 2002. Installation • • • • • • • Supplied with tie wraps Unscreened Colour code T568B. Labelling windows supplied LSA + termination UK white Fits in all UK Nexans structural hardware Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 44 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential Outlet Modules Product List Nexans ref. N424.521 N424.520 N424.523 N424.522 To be removed Name 25x50 Cat 5e Module 25x50 Cat 5e Module - Low Prole LJ6C Cat 5e Module Triple Cat 5e Module = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 45 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] essential patchcords • • • • Complies to the latest Category 5e standard Light grey PVC Screened and unscreened Moulded strain relief boot Description Application Nexans Essential patch cords are intended to be used to complete the installation of an "Essential" Category 5e system. • Flexible grey PVC. • Moulded strain relief boot. • 1.5m and 3m standard lengths. Standards International ISO/IEC 11801 Flame retardant IEC 60332-1 03/12/10 - http://www.nexans.co.uk Page 46 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] essential patchcords Characteristics Construction characteristics Outer sheath Colour Electrical characteristics Characteristic impedance Usage characteristics Mechanical durability/matings Range Flame retardant Category Product List Nexans ref. N101.122DGG N101.122FGG N101.112DGG N101.112FGG PVC Grey 100 Ohm 100 essential IEC 60332-1 Cat. 5e Name Essential Patch Cord F/UTP Cat 5 1,5m PVC grey Essential Patch Cord F/UTP Cat 5 3m PVC grey Essential Patch Cord U/UTP Cat 5 1,5m PVC grey Essential Patch Cord U/UTP Cat 5 3m PVC grey Screen Yes Yes No No = Make to order, 03/12/10 - http://www.nexans.co.uk Length (m) 1.5 3 1.5 3 = Make to stock Page 47 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Category 6 / 6A LANmark-6 is considered the best horizontal solution for most enterprise requirements by combining high performance for today, room for growth tomorrow, and high reliability and efciency. The range of systems include 10Gigabit solutions offering bandwidth up to 500MHz with extensive headroom on channel performance. Recommended uses: • • • • • Typical 5-10 year building life Typical enterprise applications - Fast Ethernet & Gigabit Ethernet 10Gigabit varients for high data environments and datacentres Where reliability is considered vital for business Typical ofce or indoor light industrial environments 03/12/10 - http://www.nexans.co.uk Page 48 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 Cable • • • • Complies to all Category 6 cable standards Supports Class E applications Central cross member maintains geometry and performance Tested up to 350MHz Description Application LANmark-6 cable is the ultimate solution for a future proof network. It is specically designed to support the exacting requirements for tomorrow's protocols, yet is fully backwards compatible with today's needs. It is the recommended cable for all forthcoming installations. • • • • • • • 10baseT Ethernet 100baseTX Fast Ethernet 1000baseTX Gigabit Ethernet 155 MBit ATM 622 MBit ATM 1.2 Gbit ATM Future class E applications LANmark-6 is independently veried to exceed the requirements of the ISO/IEC 11801:2002 Category 6 requirements. Performance Tested to 350 MHz and with guaranteed performance to 250 MHz, Nexans LANmark-6 cables provide guaranteed headroom and bandwidth over and above the requirements of all international, european and american cable standards, including ISO/IEC 11801:2002, IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568B.2-1. Standards International EN 50288; IEC 61156-5; ISO/IEC 11801 National TIA/EIA-568-B.2-1 Installation LANmark-6 is installed in exactly the same way as Category 5 cables. The C³ central cross member reduces the risk of crushing and kinking. Guarantees Nexans LANmark-6 cable is covered by the guarantee that it is Category 6 and by a parts and labour warranty as described in the Nexans Certied System Warranty. 03/12/10 - http://www.nexans.co.uk Page 49 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 Cable Product List Nexans ref. N100.623 N100.628 N100.622 N100.624 N100.627 N100.629 N100.603 N100.613 N100.601 N100.662 N100.611 N100.661 N100.633 N100.631 N100.632 N100.609 N100.619 N100.606 N100.607 N100.605 N100.616 N100.617 N100.608 Name Type of cable Category LANmark-6 F1/UTP Dual LSZH FTP Shotgun 500m reel LANmark-6 F1/UTP Dual PVC FTP Shotgun 500m reel LANmark-6 F1/UTP LSZH 1000m F/UTP reel LANmark-6 F1/UTP LSZH 500m F/UTP reel LANmark-6 F1/UTP PVC 1000m F/UTP reel LANmark-6 F1/UTP PVC 500m F/UTP reel LANmark-6 F²/UTP Dual LSZH F²TP Shotgun 500m reel LANmark-6 F²/UTP Dual PVC F²TP Shotgun 500m reel LANmark-6 F²/UTP LSZH 1000m F²TP reel LANmark-6 F²/UTP LSZH 500m F²TP reel LANmark-6 F²/UTP PVC 1000m F²TP reel LANmark-6 F²/UTP PVC 500m F²TP reel LANmark-6 SF/UTP Dual LSZH SF/UTP 500m reel Shotgun LANmark-6 SF/UTP LSZH 1000m SF/UTP reel LANmark-6 SF/UTP LSZH 500m SF/UTP reel LANmark-6 U/UTP Dual LSZH U/UTP 500m reel LANmark-6 U/UTP Dual PVC U/UTP 500m reel LANmark-6 U/UTP LSZH 1000m U/UTP reel LANmark-6 U/UTP LSZH 305m U/UTP Box LANmark-6 U/UTP LSZH 500m U/UTP reel LANmark-6 U/UTP PVC 1000m U/UTP reel LANmark-6 U/UTP PVC 305m U/UTP Box LANmark-6 U/UTP PVC 500m U/UTP reel =Make to order, =Make to stock Outer Conductor cross-section sheath (AWG) Cat. 6 LSZH 24 Cat. 6 PVC 24 Cat. 6 LSZH 24 Cat. 6 LSZH 24 Cat. 6 PVC 24 Cat. 6 PVC 24 Cat. 6 LSZH 24 Cat. 6 PVC 24 Cat. 6 LSZH 24 Cat. 6 LSZH 24 Cat. 6 PVC 24 Cat. 6 PVC 24 Cat. 6 LSZH 23 Cat. 6 LSZH 23 Cat. 6 LSZH 23 Cat. 6 LSZH 23 Cat. 6 PVC 23 Cat. 6 LSZH 23 Cat. 6 LSZH 23 Cat. 6 LSZH 23 Cat. 6 PVC 23 Cat. 6 PVC 23 Cat. 6 PVC 23 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 50 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 Cable Electrical Performance All values are specied at 20°C Frequency Attenuation dB/100m NEXT dB ACR dB/100m PSNEXT(*) dB ELFEXT dB/100m PSELFEXT dB/100m RL dB 1 2.0 74.3 72.3 72.3 70.0 67.0 20.0 4 3.8 65.3 61.5 63.3 58.0 55.0 23.0 10 6.0 59.3 53.3 57.3 50.0 47.0 25.0 16 7.6 56.2 48.6 54.3 45.9 42.9 25.0 20 8.5 54.8 46.3 52.8 44.0 41.0 25.0 31.25 10.7 51.9 41.2 49.9 40.5 37.5 23.6 62.5 15.4 47.4 32.0 45.4 34.1 31.1 21.5 100 19.8 44.3 24.5 42.3 30.0 27.0 20.1 155 25.2 41.4 16.2 39.5 26.2 23.2 18.8 200 29.0 39.8 10.8 37.8 24.0 21.0 18.0 250 32.8 38.3 5.5 36.3 22.0 19.0 17.3 300 36.4 37.1 1.5 35.2 20.5 17.5 16.8 350 39.8 36.1 - 34.2 19.1 16.1 14.1 (*) Dual cable versions additionally comply to the additional PSNEXT requirements for multi-unit cables as specied in the relevant TIA and IEC cable standards. 03/12/10 - http://www.nexans.co.uk Page 51 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 Snap-In Connector • • • • Cat 6 Snap-In available in 3 versions UTP, FTP, EMC. Fits in all structural hardware designed for this range. Easy termination, without punch down tool. An adapter can be added to t the keystone format Description Application The LANmark-6 Toolless Snap-In Connector is part of the Nexans modular system and ts in all structural hardware designed for this range. As such it supports all data applications dened for Cat 5, Cat 5e and Cat 6, such as 10baseT, Fast Ethernet, Gigabit Ethernet, 155 ATM, 622 ATM, 1.2 ATM… Performance The LANmark-6 Snap-In Connector has been designed to reach the highest performance in Cat 6 and Class E. It has outstanding performance for attenuation (insertion loss), NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss, exceeding the Cat 6 connector specs as in ISO/IEC 11801:2002. The unique cross-technology in the connector ensures the high performance of the link. Used with Nexans LANmark-6 cables and patchcords, the connector is independently tested to exceed the link and stringent four-connector channel requirements as dened in the ISO/IEC 11801:2002. Guarantees The LANmark-6 Snap-In Connector is covered by the guarantee as in 'The General Terms and Conditions of Sales'. In combination with the Nexans LANmark-6 product range, the Nexans Certied System Warranty can be obtained, covering parts, system and labour warranty. Standards International ISO/IEC 11801 Installation The LANmark-6 Snap-In Connector is a toolless connector. It is designed to be terminated by hand, without punchdown tool. For faster and easier installation of large volumes, an optional comfort tool can be used. • • • • Fast termination of cable Colour code : TSB568A &TSB568B Can be used with all types of cables : F²TP, UTP or STP Accepts 24, 23 and 22 AWG cable 03/12/10 - http://www.nexans.co.uk Page 52 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 Snap-In Connector Characteristics Usage characteristics Category Product List Nexans ref. N420.666 New N420.667 New N420.660 New N420.661 New Cat. 6 =Make to order, =Make to stock Height Width Range (mm) (mm) Name LANmark-6 EVO Snap- in connector, Toolless connectivity, screened, with rear cover (EMC) for solid wire LANmark-6 EVO Snap-in connector, Toolless connectivity, screened, with rear cover (EMC) for stranded wire LANmark-6 EVO Snap-in connector, Toolless connectivity, unscreened for solid wire LANmark-6 EVO Snap-in connector, Toolless connectivity, unscreened for stranded wire 23.2 16.8 LANmark-6 23.2 16.8 LANmark-6 22.9 16.7 LANmark-6 22.9 16.7 LANmark-6 = Make to order, = Make to stock Electrical Performance Frequency MHz Attenuation NEXT pp PSNEXT FEXT pp PSFEXT RL 1 0.1 94.0 90.0 83.1 80.1 30.0 4 0.1 82.0 78.0 71.1 68.1 30.0 10 0.1 74.0 70.0 63.1 60.1 30.0 16 0.1 69.9 65.9 59.0 56.0 30.0 20 0.1 68.0 64.0 57.1 54.1 30.0 31.25 0.1 64.1 60.1 53.2 50.2 30.0 62.5 0.2 58.1 54.1 47.2 44.2 28.1 100 0.2 54.0 50.0 43.1 40.1 24.0 125 0.2 52.1 48.1 41.2 38.2 22.1 155 0.2 50.2 46.2 39.3 36.3 20.2 175 0.3 49.1 45.1 38.2 35.2 19.1 200 0.3 48.0 44.0 37.1 34.1 18.0 250 0.3 46.0 42.0 35.1 32.1 16.0 All values are in dB 03/12/10 - http://www.nexans.co.uk Page 53 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 UniBoot Patch Cords • • • • • Complies fully with Category 6 standards Uses Nexans cable technology Fully matched with other components for maximum performance LSZH Flame retardant jacket Retrot Latch Protector available in 8 colours for colour coding Description Application LANmark-6 Patch Cords can be used to deliver a full end-to-end Class E solution. They provide improved data throughput and allow for the inclusion of a crossconnect or Consolidation Points for maximum system exibility. They will also maximise the lifetime and long term performance of the system by minimising the risk of wear & tear damage which can be caused by using non-matched cords. . LANmark-6 Cords feature a slim over-moulded boot which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a Retrot Latch Protector, which can be used for colour coding of different services. Guarantees When installed in combination with other LANmark-6 components, a 25 years channel warranty can be obtained, covering full Cat 6/Class E compliance. Installation • Small cross section allows neat installation and simplies the creation of bundles in cabinets. • A Low Smoke Zero Halogen - Flame Retardant jacket is standard. • 1, 2, 3, 5, 10 and 20m are standard lengths; other lengths are available on demand. • Orange and Dark Grey are standard colours available from stock; other colours are available on demand. • Default Plug conguration is a black boot with a preinstalled black latch protector; other combinations available on request. 03/12/10 - http://www.nexans.co.uk Standards International EN 50173 Ed.1; ISO/ IEC 11801 National TIA/EIA-568-B.2-1 Page 54 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 UniBoot Patch Cords Product List Nexans ref. N116.P1A100DK New N116.P1A100OK New N116.P1A010DK New N116.P1A010OK New N116.P1A200DK New N116.P1A200OK New N116.P1A020DK New N116.P1A020OK New N116.P1A030DK New N116.P1A030OK New N116.P1A050DK New N116.P1A050OK New Name LANmark-6 Patch Cord Cat 6 Unscreened LSZH 10m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 10m Orange LANmark-6 Patch Cord Cat 6 Unscreened LSZH 1m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 1m Orange LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 20m Orange LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 2m Orange LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 3m Orange LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m Grey LANmark-6 Patch Cord Cat 6 Unscreened LSZH 5m Orange =Make to order, =Make to stock Range Colour Screen Length (m) LANmark-6 Grey No 10 LANmark-6 Orange No 10 LANmark-6 No 1 LANmark-6 Orange No 1 LANmark-6 No 20 LANmark-6 Orange No 20 LANmark-6 No 2 LANmark-6 Orange No 2 LANmark-6 No 3 LANmark-6 Orange No 3 LANmark-6 No 5 No 5 Grey Grey Grey Grey Grey LANmark-6 Orange = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 55 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 10G UniBoot Patch Cords • High speed RJ45 patch cord to run 10GBase-T (IEEE 802.3an) • High Density support : 48 cords on 1 height unit • Frequency up to 500MHz, fully complies to Cat 6A channel requirements • Screened Design for Alien Crosstalk immunity • Externally certied • Retrot Latch Protector available in 6 colors for color coding Description Application LANmark-6 10G Cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an). LANmark-6 10G Cords offer superior performance up to 500MHz and are matched with other LANmark-6 10G components to provide improved data throughput in complex channel congurations. LANmark-6 10G Cords use stranded cable and as such provide maximum system exibility for the use at Cross Connects and Consolidation points. LANmark-6 10G Cords feature a robust boot which does not extent outside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit and an Retrot Latch Protector, which can be used for color coding of different services. Performance LANmark-6 10G Cords fully comply and exceed the channel requirements of EIA/ TIA-568-B.2-10 and ISO11801 A2 and enable to achieve high performing 10G channels. Standards Guarantees When installed in combination with other LANmark-6 10G components, a 25 years channel warranty can be obtained, covering full 10GBase-T support and full Cat 6A/Class EA compliance. Usage International IEEE 802.3an; ISO/ IEC TR24750; ISO11801:2002/ A1:2008 National TIA/EIA TSB-155; TIA/ EIA-568-B.2-10 • The cords are by design fully Alien Crosstalk compliant, so no special installation rules need to be taken into account for ANEXT and AFEXT compliance. • 1, 2, 3, 5, 10, 20m are standard lengths available from stock, other lengths are available on demand. • Orange and Dark Grey are standard colours available from stock, other colours are available on demand. • Default Plug conguration is a black boot with a preinstalled black latch protector, other combinations available on request. 03/12/10 - http://www.nexans.co.uk Page 56 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 10G UniBoot Patch Cords Product List Nexans ref. Name N11G.P1B100DK New N11G.P1B100OK New N11G.P1B010DK New New N11G.P1B010OK New N11G.P1B200DK New N11G.P1B200OK New N11G.P1B020DK New N11G.P1B020OK New N11G.P1B030DK New N11G.P1B030OK New N11G.P1B050DK New N11G.P1B050OK New LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 10m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 10m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 1m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 1m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 1m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 20m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 20m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 2m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 2m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 3m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 3m Orange LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 5m Grey LANmark-6 10G Patch Cord Cat 6 500MHz Screened LSZH 5m Orange =Make to order, Range Length (m) LANmark-6 10 10G LANmark-6 10 10G LANmark-6 1 10G LANmark-6 1 10G LANmark-6 1 10G LANmark-6 20 10G LANmark-6 20 10G LANmark-6 2 10G LANmark-6 2 10G LANmark-6 3 10G LANmark-6 3 10G LANmark-6 5 10G LANmark-6 5 10G = Make to order, =Make to stock Colour Screen Grey Yes Orange Yes Grey Yes Orange Yes Orange Yes Grey Yes Orange Yes Grey Yes Orange Yes Grey Yes Orange Yes Grey Yes Orange Yes = Make to stock Electrical Performance LANmark-6 10G 100m 4 connector channel all values are specied at 20°C Attn dB Freq Std NEXT dB Guar Std PSNEXT dB ELFEXT dB Guar Std Guar Std PS ELFEXT dB PS ANEXT dB PS AELFEXT dB RL dB Guar Std Guar Std Guar Std Guar Std Guar 1 <4 <4 72.7 >75 70.3 74.3 63.3 >60 60.3 >60 82.0 >90 77.9 87.9 19.0 21.0 4 4.2 4.1 63.0 66.0 60.5 64.5 51.2 57.2 48.2 57.2 76.0 >90 65.9 75.9 19.0 21.0 10 6.6 6.5 56.6 59.6 54.0 58.0 43.3 49.3 40.3 49.3 72.0 87.0 57.9 67.9 19.0 21.0 16 8.3 8.2 53.2 56.2 50.6 54.6 39.2 45.2 36.2 45.2 70.0 85.0 53.8 63.8 18.0 20.0 20 9.3 9.2 51.6 54.6 49.0 53.0 37.2 43.2 34.2 43.2 69.0 84.0 51.9 61.9 17.5 19.5 31.25 11.7 11.6 48.4 51.4 45.7 49.7 33.4 39.4 30.4 39.4 67.1 82.1 48.0 58.0 16.5 18.5 62.5 16.9 16.6 43.4 46.4 40.6 44.6 27.3 33.3 24.3 33.3 64.0 79.0 42.0 52.0 14.0 16.0 100 21.7 21.4 39.9 42.9 37.1 41.1 23.3 29.3 20.3 29.3 62.0 77.0 37.9 47.9 12.0 14.0 155 27.6 27.1 36.7 39.7 33.8 37.8 19.5 25.5 16.5 25.5 59.1 74.1 34.1 44.1 10.1 12.1 200 31.7 31.2 34.8 37.8 31.9 35.9 17.2 23.2 14.2 23.2 57.5 72.5 31.9 41.9 9.0 11.0 250 35.9 35.4 33.1 36.1 30.2 34.2 15.3 21.3 12.3 21.3 56.0 71.0 29.9 39.9 8.0 10.0 300 39.8 39.2 31.7 34.7 28.8 32.8 13.7 19.7 10.7 19.7 54.8 69.8 28.4 38.4 7.2 9.2 500 53.4 52.6 22.0 25.0 20.4 24.4 9.3 15.3 6.3 15.3 51.5 66.5 23.9 33.9 6.0 8.0 Guaranteed channel values apply under the condition that General Installation Guidelines from NCS and the Design and Installation Guidelines for LANmark-6 10G are respected and implemented. 03/12/10 - http://www.nexans.co.uk Page 57 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 10G Snap-In Connector • • • • • • Complies to 10GBase-T application standards Complies with Category 6A and Class EA channel requirements Fully screened for alien crosstalk immunity Reduces risk of installation errors for consistent performance Compatible with all snap-in hardware An adapter can be added to t the keystone format Description Application LANmark-6 10G consists of screened components specied to frequencies up to 500MHz. They have been designed specically to support the higher frequencies required for 10 Gigabit Ethernet, yet is fully backwards compatible with today's needs. The LANmark-6 10G EVO connector ts in all structural hardware designed for the EVO snap-in range. In addition to the requirements of the EIA/ TIA 568-B.2-1 and ISO/IEC 11801:2002 Category 6, the LANmark-6 10G products are additionally specied to 500MHz and are screened to ensure immunity from Alien Crosstalk and other external interference. • • • • • • • 10Base-T Ethernet 100Base-TX Fast Ethernet 1000Base-TX Gigabit Ethernet 10GBase-T 10 Gigabit Ethernet IEEE 802.3 155 Mbit ATM 1.2 Gbit ATM future class E 10G applications Performance The LANmark-6 10G EVO Snap-in connector has been designed to reach the highest performance in Cat 6 and Class E up to 500 MHz. It has outstanding performance for attenuation (insertion loss), NEXT/FEXT, Power Sum NEXT/ FEXT and Return Loss, exceeding the Cat 6 connector specs as in IEC 60603-7-5. Standards International IEEE 802.3an; ISO/ IEC TR24750; ISO11801:2002/ A1:2008 National TIA/EIA TSB-155; TIA/ EIA-568-B.2-10 When used in combination with Nexans LANmark-6 10G cables and LANmark-6 10G Ultim patch cords, and installed according to the guidelines, the system supports the 10GBase-T applications as dened in IEEE 802.3an, ISO/IEC TR 24750 and TIA/EIA TSB-155. Respecting the Nexans LANmark-6 10G design guidelines, the full 100m four-connector channel moreover meets Category 6A and Class EA requirements as dened in TIA/EIA568B.2 Addendum 10 draft 6.0 and ISO/IEC draft amendment 1.1 (as in draft 25N1324) respectively. Installation The LANmark-6 10G EVO Snap-in connector makes termination easier and quicker thanks to exclusive design of the wire organizer and of the sliding metal EMC rear cover. The LANmark-6 10G EVO snap-in is designed to be terminated with the universal comfort tool. This tool includes also the exclusive extraction mechanism which makes the EVO series snap-in re-usable. A stranded version is available for reliable termination in consolidation point of 3 or 4 connectors channel models. The LANmark-6 10G EVO snap-in range is Nexans technology inside and user friendly outside 03/12/10 - http://www.nexans.co.uk Page 58 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 10G Snap-In Connector • • • • • • • • Fast termination with exclusive wire organizer and sliding metal EMC rear cover Colour code : T568A &T568B Full EMC protection with metal rear cover Re-usable with universal comfort tool Accepts solid wire from 22 to 24 AWG Stranded version available for consolidation point Snap-in format ts in all Nexans structural hardware 2 possibilities to terminate the drain wire : on the housing or on the rear cover Guarantees The LANmark-6 10G EVO Snap-in connector is covered by the guarantee as in The General Terms and Conditions of Sales. When installed in combination with other LANmark-6 10G components, a 25 years channel warranty can be obtained, covering 10GBase-T support in accordance with IEEE 802.3an. Also if following the design guidelines for LANmark-6 10G systems and tested accordingly, a 25 year warranty can be obtained to Category 6A or Class EA requirements. 03/12/10 - http://www.nexans.co.uk Page 59 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6 10G Snap-In Connector Characteristics Usage characteristics Range LANmark-6 10G Product List Nexans ref. N420.666G New N420.667G New Name LANmark-6 10G EVO Snap-in connector, screened, for solid wire LANmark-6 10G EVO Snap-in connector, screened, for stranded wire = Make to order, = Make to stock Electrical Performance LANmark-6 10G 100m 4 connector channel all values are specied at 20°C Attn dB Freq Std NEXT dB Guar Std PSNEXT dB ELFEXT dB Guar Std Guar Std PS ELFEXT dB PS ANEXT dB PS AELFEXT dB RL dB Guar Std Guar Std Guar Std Guar Std Guar 1 <4 <4 72.7 >75 70.3 74.3 63.3 >60 60.3 >60 82.0 >90 77.9 87.9 19.0 21.0 4 4.2 4.1 63.0 66.0 60.5 64.5 51.2 57.2 48.2 57.2 76.0 >90 65.9 75.9 19.0 21.0 10 6.6 6.5 56.6 59.6 54.0 58.0 43.3 49.3 40.3 49.3 72.0 87.0 57.9 67.9 19.0 21.0 16 8.3 8.2 53.2 56.2 50.6 54.6 39.2 45.2 36.2 45.2 70.0 85.0 53.8 63.8 18.0 20.0 20 9.3 9.2 51.6 54.6 49.0 53.0 37.2 43.2 34.2 43.2 69.0 84.0 51.9 61.9 17.5 19.5 31.25 11.7 11.6 48.4 51.4 45.7 49.7 33.4 39.4 30.4 39.4 67.1 82.1 48.0 58.0 16.5 18.5 62.5 16.9 16.6 43.4 46.4 40.6 44.6 27.3 33.3 24.3 33.3 64.0 79.0 42.0 52.0 14.0 16.0 100 21.7 21.4 39.9 42.9 37.1 41.1 23.3 29.3 20.3 29.3 62.0 77.0 37.9 47.9 12.0 14.0 155 27.6 27.1 36.7 39.7 33.8 37.8 19.5 25.5 16.5 25.5 59.1 74.1 34.1 44.1 10.1 12.1 200 31.7 31.2 34.8 37.8 31.9 35.9 17.2 23.2 14.2 23.2 57.5 72.5 31.9 41.9 9.0 11.0 250 35.9 35.4 33.1 36.1 30.2 34.2 15.3 21.3 12.3 21.3 56.0 71.0 29.9 39.9 8.0 10.0 300 39.8 39.2 31.7 34.7 28.8 32.8 13.7 19.7 10.7 19.7 54.8 69.8 28.4 38.4 7.2 9.2 500 53.4 52.6 22.0 25.0 20.4 24.4 9.3 15.3 6.3 15.3 51.5 66.5 23.9 33.9 6.0 8.0 Guaranteed channel values apply under the condition that General Installation Guidelines from NCS and the Design and Installation Guidelines for LANmark-6 10G are respected and implemented. 03/12/10 - http://www.nexans.co.uk Page 60 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Cable • • • • • Ideal Cable for 10GBase-T application Complies fully with new standards for Category 6A and Class EA Small diameter Guaranteed performance up to 500MHz Fully screened for alien crosstalk immunity Description Application LANmark-6A cable is the ideal solution for a 10 Gigabit Ethernet network. The range consists of cables which have been designed specically to support the higher frequencies required for 10 Gigabit Ethernet, while maintain to be fully backwards compatible with today's needs. All LANmark-6A products are screened cables to ensure immunity from Alien Crosstalk and other external interference and are specied up to frequencies of 500MHz. • • • • • • • 10Base-T Ethernet 100Base-TX Fast Ethernet 1000Base-TX Gigabit Ethernet 10GBase-T 10 Gigabit Ethernet IEEE 802.3 155 Mbit ATM 1.2 Gbit ATM future Cat 6A and Class EA applications Performance With guaranteed performance to 500MHz, Nexans LANmark-6A cables provide guaranteed headroom and bandwidth over and above the Category 6A requirements of international, european and american cable standards, including of IEC 61156-5, EN 50173, EN 50288, TIA/EIA 568-B.2-1 Ad.10. When used in combination with Nexans LANmark-6A Evo connectors and LANmark-6A Ultim patch cords, the system supports the 10GBase-T applications as dened in IEEE 802.3an, and the full 100m four-connector links and channels meet Category 6A and Class EA requirements as dened in TIA/EIA568B.2 Addendum 10 and ISO/ IEC11801 2002/A1:2008. International EN 50288-4-1; IEC 61156-5; IEEE 802.3an; ISO/ IEC 11801:2002/A2:2008; ISO/ IEC 24764; ISO/IEC TR24750; ISO11801:2002/A1:2008 Installation National ANSI/TIA-568-C.2; TIA/ EIA TSB-155 Standards The LANmark-6A cables have the advantage of offering equal dimensions and exibility as the equivalent LANmark-6 screened cables with the same ease of installation and termination. Guarantees Nexans LANmark-6A 10G cable is covered by a parts and labour warranty as described in the Nexans Certied System Warranty. When installed in combination with other LANmark-6A 10G components, a 25 year channel warranty can be obtained. 03/12/10 - http://www.nexans.co.uk Page 61 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Cable =Make to order, Product List Nexans ref. N100.693G N100.698G N100.692G N100.694G N100.697G N100.699G N100.623G N100.622G N100.624G Name LANmark-6A F/FTP Cat 6A 500MHz Dual LSZH 500m reel LANmark-6A F/FTP Cat 6A 500MHz Dual PVC 500m reel LANmark-6A F/FTP Cat 6A 500MHz LSZH 1000m reel LANmark-6A F/FTP Cat 6A 500MHz LSZH 500m reel LANmark-6A F/FTP Cat 6A 500MHz PVC 1000m reel LANmark-6A F/FTP Cat 6A 500MHz PVC 500m reel LANmark-6A F1/UTP Cat 6A 500MHz Dual LSZH 500m reel LANmark-6A F1/UTP Cat 6A 500MHz LSZH 1000m reel LANmark-6A F1/UTP Cat 6A 500MHz LSZH 500m reel =Make to stock Outer sheath LSZH PVC LSZH LSZH PVC PVC LSZH LSZH LSZH = Make to order, = Make to stock Electrical Performance LANmark-6A 10G F1UTP cable Attn Freq in dB NEXT in dB PSNEXT in dB ACR-F in dB PS ACR-F in dB in MHz Max. Typ. Min. Typ. Min. Typ. Min. Typ. Min. 1 2.1 2.1 74.3 79.3 72.3 77.3 67.8 92.8 4 3.8 3.8 65.3 70.3 63.3 68.3 55.8 80.8 10 5.9 5.9 59.3 64.3 57.3 62.3 47.8 16 7.5 7.5 56.2 61.2 54.2 59.2 43.7 PS ANEXT in dB PS AACR-F in dB RL in dB Typ. Min. Typ. Min. Typ. Min. Typ. 64.8 >60 67.0 90.0 67.0 87.9 20.0 26.0 52.8 57.2 67.0 90.0 66.2 75.9 23.0 29.0 72.8 44.8 49.3 67.0 87.0 58.2 67.9 25.0 31.0 68.7 40.7 45.2 67.0 85.0 54.1 63.8 25.0 31.0 20 8.4 8.4 54.8 59.8 52.8 57.8 41.8 66.8 38.8 43.2 67.0 84.0 52.2 61.9 25.0 31.0 31.25 10.5 10.5 51.9 56.9 49.9 54.9 37.9 62.9 34.9 39.4 67.0 82.1 48.3 58.0 23.6 29.6 62.5 15.0 15.0 47.4 52.4 45.4 50.4 31.9 56.9 28.9 33.3 65.6 79.0 42.3 52.0 21.5 27.5 100 19.1 19.1 44.3 49.3 42.3 47.3 27.8 52.8 24.8 29.3 62.5 77.0 38.2 47.9 20.1 26.1 155 24.1 24.1 41.4 46.4 39.4 44.4 24.0 49.0 21.0 25.5 59.6 74.1 34.4 44.1 18.8 24.8 200 27.6 27.6 39.8 44.8 37.8 42.8 21.8 46.8 18.8 23.2 58.0 72.5 32.2 41.9 18.0 24.0 250 31.1 31.1 38.3 43.3 36.3 41.3 19.8 44.8 16.8 21.3 56.5 71.0 30.2 39.9 17.3 23.3 300 34.3 34.3 37.1 42.1 35.1 40.1 18.3 43.3 15.3 19.7 55.3 69.8 28.7 38.4 16.8 22.8 500 45.3 45.3 33.8 38.8 31.8 36.8 13.8 38.8 10.8 15.3 52.0 66.5 24.2 33.9 15.2 21.2 all values are specied at 20°C 03/12/10 - http://www.nexans.co.uk Page 62 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Connector • • • • • High bandwidth RJ45 connector to support 10Gigabit Ethernet Fully complies to TIA and ISO Cat 6A cabling standards Supports extremely short Cat 6A channel congurations needed for datacenters Fully screened for alien crosstalk immunity Compatible with all Snap-In panels and outlets Description Application LANmark-6A EVO Snap-In Connector is a screened RJ45 cable jack specied up to 500MHz. It is designed specically to support the high frequencies required for 10 Gigabit Ethernet, but is also fully backwards-compatible with lower frequency applications using the RJ45 interface. LANmark-6A EVO uses a fully closed rear cover, which provides 360° screening and excellent coupling attenuation to ensure immunity from alien crosstalk and other external interference. Cabling channels with LANmark-6A cable jack have not to be veried on site for Alien Crosstalk, as this new 10G parameter is met by design. This reduces signicantly the cost for 10G networking. • • • • • • • 10Base-T Ethernet 100Base-TX Fast Ethernet 1000Base-TX Gigabit Ethernet 10GBase-T 10 Gigabit Ethernet IEEE 802.3 155 Mbit ATM 1.2 Gbit ATM all future Cat 6A and Class EA applications Performance The LANmark-6A EVO has outstanding electrical performance up to 500MHz especially for NEXT/FEXT, Power Sum NEXT/FEXT, Return Loss and all screening parameters. This enables to achieve high performing Cat 6A channels as well as very short link and channel congurations needed in data centres with up to 3 connection points within 12 meters. Standards International EN 50173-1; EN 50173-3; IEC 60603-7-5; IEC 60603-7-51; ISO/ IEC 11801:2002/A2:2008; ISO/ IEC 24764; ISO11801:2002/A1:2008 National ANSI/TIA-568-C.2 Installation LANmark-6A EVO makes use of Nexans wire organiser and is therefore very easy and fast to terminate. Using the Nexans comfort tool installation tool EVO Snap-In series is re-usable. A stranded version is available to allow the use of exible stranded cable in cross connects or consolidation point. The LANmark-6A EVO ts in all structural hardware designed for the EVO SnapIn range and can used in all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO). • Fast termination with exclusive wire organizer and hinging metal EMC rear cover • Colour code : T568A &T568B • 360° EMC protection • Re-usable with universal comfort tool • Accepts solid wire from 22 to 24 AWG • Stranded version available for consolidation point • Snap-in format ts in all Nexans structural hardware • 2 possibilities to terminate the drain wire : on the housing or on the rear cover • Can be turned into keystone format using an additional adapter Guarantees When installed in combination with other LANmark-6A components, a 25 years channel warranty can be obtained, covering full 10GBase-T support and full Cat 6A/Class EA compliance 03/12/10 - http://www.nexans.co.uk Page 63 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Connector Product List Nexans ref. N420.66A New N420.67A New Name LANmark-6A Snap-In Connector Cat 6A 500MHz Screened LANmark-6A Snap-In Connector Cat 6A 500MHz Screened for stranded wire = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 64 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Connector Electrical Performance LANmark-6A 4 Connector Channel Part 1 "All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance" Attn Freq in MHz NEXT in dB PSNEXT in dB ACR-F in dB in dB Max Typ Std Min Typ Std Min Typ Std Typ 1 <4 4.0 65.0 67.0 85.0 62.0 64.0 74.8 63.3 69.9 4 4.1 4.1 63.0 65.0 72.9 60.5 62.5 65.0 51.2 57.9 10 6.4 6.3 56.6 58.6 65.0 54.0 56.0 58.5 43.3 49.9 16 8.1 8.0 53.2 55.2 60.9 50.6 52.6 55.1 39.2 45.9 20 9.1 9.0 51.6 53.6 59.0 49.0 51.0 53.5 37.2 43.9 31.25 11.4 11.2 48.4 50.4 55.1 45.7 47.7 50.2 33.4 40.0 62.5 16.3 15.9 43.4 45.4 49.1 40.6 42.6 45.1 27.3 34.0 100 20.8 20.2 39.9 41.9 45.0 37.1 39.1 41.6 23.3 29.9 155 26.2 25.4 36.7 38.7 41.2 33.8 35.8 38.3 19.5 26.1 200 30.0 28.9 34.8 36.8 39.0 31.9 33.9 36.4 17.2 23.9 250 33.8 32.5 33.1 35.1 37.0 30.2 32.2 34.7 15.3 22.0 300 37.3 35.7 31.7 33.7 35.4 28.8 30.8 33.3 13.7 20.4 500 49.3 46.7 27.9 29.9 31.0 24.8 26.8 24.9 9.3 16.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA Electrical Performance LANmark-6A 4 Connector Channel Part 2 All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance PS ACR-F Freq PS ANEXT in dB PS AACR-F in dB RL in dB in dB in MHz Std Typ Std Min Typ Std Min Typ Std Min Typ 1 60.3 66.9 80.0 90.0 92.0 77.0 92.0 94.0 19.0 21.0 21.0 4 48.2 54.9 74.0 89.0 91.0 65.0 80.0 82.0 19.0 21.0 32.0 10 40.3 46.9 70.0 85.0 87.0 57.0 72.0 74.0 19.0 21.0 28.0 16 36.2 42.9 68.0 83.0 85.0 52.9 67.9 69.9 18.0 20.0 26.0 20 34.2 40.9 67.0 82.0 84.0 51.0 66.0 68.0 17.5 19.5 25.0 31.25 30.4 37.0 65.1 80.1 82.1 47.1 62.1 64.1 16.5 18.5 23.1 62.5 24.3 31.0 62.0 77.0 79.0 41.1 56.1 58.1 14.0 16.0 20.0 100 20.3 26.9 60.0 75.0 77.0 37.0 52.0 54.0 12.0 14.0 18.0 155 16.5 23.1 57.1 72.1 74.1 33.2 48.2 50.2 10.1 12.1 16.1 200 14.2 20.9 55.5 70.5 72.5 31.0 46.0 48.0 9.0 11.0 15.0 250 12.3 19.0 54.0 69.0 71.0 29.0 44.0 46.0 8.0 10.0 14.0 300 10.7 17.4 52.8 67.8 69.8 27.5 42.5 44.5 8.0 10.0 13.2 500 6.3 13.0 49.5 64.5 66.5 23.0 38.0 40.0 8.0 10.0 11.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA 03/12/10 - http://www.nexans.co.uk Page 65 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Ultim UniBoot Patch Cords • • • • • • High speed RJ45 patch cord to run 10GBase-T and future Cat6A applications High Density support : 48 cords on 1 height unit Frequency range up to 500MHz, fully complies to Cat 6A TIA568B.2-10 and ISO11801(2010) A2 Individually screened pairs for reduced Internal Crosstalk and Alien Crosstalk immunity Externally certied Retrot Latch Protector available in 8 colours for colour coding Description Application LANmark-6A Ultim cords are developed to support 10 Gigabit Ethernet (IEEE 802.3an) and any other future Cat.6A application. LANmark-6A Ultim Cords offer superior performance up to 500MHz and are matched with other LANmark-6A components to provide improved data throughput in complex channel congurations. Ultim cords use stranded cable and as such provide maximum system exibility for the use at Cross Connects and Consolidation points. They will also maximise the lifetime and longevity of the system by minimising the risk of wear & tear damage. Due to their good electrical performance and mechanical stability, LANmark-6A Ultim cords can be used for accurate eld testing of Cat 6A cabling channels. . Ultim Cords feature a slim boot for mechanical protection, which is kept inside the RJ45 boundaries to enable High Density Patching with 48 cords in 1 height unit. They also come with a ‘Replaceable’ Latch Protector, which can be used for colour coding of different services. Performance Standards The LANmark-6A Ultim cords fully comply and exceed the requirements of EIA/ TIA-568-B.2-10 and ISO11801 A2 and enable to achieve high performing Cat 6A channels. Used with other LANmark-6A components, very short Cat 6A link and channel congurations with up to 3 connection points within 10 meters can be supported. International EN 50173-1; IEEE 802.3an; ISO/IEC 11801:2002/ A2:2008; ISO/IEC TR24750; ISO11801:2002/A1:2008 National TIA/EIA TSB-155; TIA/ EIA-568-B.3 Guarantees When installed in combination with other LANmark-6A components, a 25 years channel warranty can be obtained, covering full 10GBase-T support and full Cat 6A/Class EA compliance. Usage • The cords are by design fully Alien Crosstalk compliant, so no special installation rules need to be taken into account for ANEXT and AFEXT compliance. • 1, 2, 3, 5, 10, 20m are standard lengths available from stock, other lengths are available on demand. • Orange and Dark Grey are standard colours available from stock; other colours are available on demand. • Default Plug Conguration is a black boot with a preinstalled black latch protector. Characteristics Usage characteristics Range LANmark-6A 03/12/10 - http://www.nexans.co.uk Page 66 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Ultim UniBoot Patch Cords Product List Nexans ref. N11A.U1F100DK New N11A.U1F100OK New N11A.U1F010DK New N11A.U1F010OK New N11A.U1F200DK New N11A.U1F200OK New N11A.U1F020DK New N11A.U1F020OK New N11A.U1F030DK New N11A.U1F030OK New N11A.U1F050DK New N11A.U1F050OK New =Make to order, =Make to stock Length (m) Colour Screen Name LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 10m Grey 10 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 10m Orange 10 Orange Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 1m Grey 1 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 1m Orange 1 Orange Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 20m Grey 20 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 20m Orange 20 Orange Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 2m Grey 2 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 2m Orange 2 Orange Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 3m Grey 3 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 3m Orange 3 Orange Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 5m Grey 5 Grey Yes LANmark-6A Ultim Patch Cord Cat 6A Screened LSZH 5m Orange 5 Orange Yes = Make to order, = Make to stock Electrical Performance LANmark-6A 4 Connector Channel Part 1 "All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance" Attn Freq in MHz NEXT in dB PSNEXT in dB ACR-F in dB in dB Max Typ Std Min Typ Std Min Typ Std Typ 1 <4 4.0 65.0 67.0 85.0 62.0 64.0 74.8 63.3 69.9 4 4.1 4.1 63.0 65.0 72.9 60.5 62.5 65.0 51.2 57.9 10 6.4 6.3 56.6 58.6 65.0 54.0 56.0 58.5 43.3 49.9 16 8.1 8.0 53.2 55.2 60.9 50.6 52.6 55.1 39.2 45.9 20 9.1 9.0 51.6 53.6 59.0 49.0 51.0 53.5 37.2 43.9 31.25 11.4 11.2 48.4 50.4 55.1 45.7 47.7 50.2 33.4 40.0 62.5 16.3 15.9 43.4 45.4 49.1 40.6 42.6 45.1 27.3 34.0 100 20.8 20.2 39.9 41.9 45.0 37.1 39.1 41.6 23.3 29.9 155 26.2 25.4 36.7 38.7 41.2 33.8 35.8 38.3 19.5 26.1 200 30.0 28.9 34.8 36.8 39.0 31.9 33.9 36.4 17.2 23.9 250 33.8 32.5 33.1 35.1 37.0 30.2 32.2 34.7 15.3 22.0 300 37.3 35.7 31.7 33.7 35.4 28.8 30.8 33.3 13.7 20.4 500 49.3 46.7 27.9 29.9 31.0 24.8 26.8 24.9 9.3 16.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA 03/12/10 - http://www.nexans.co.uk Page 67 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Ultim UniBoot Patch Cords Electrical Performance LANmark-6A 4 Connector Channel Part 2 All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance PS ACR-F Freq PS ANEXT in dB PS AACR-F in dB RL in dB in dB in MHz Std Typ Std Min Typ Std Min Typ Std Min Typ 1 60.3 66.9 80.0 90.0 92.0 77.0 92.0 94.0 19.0 21.0 21.0 4 48.2 54.9 74.0 89.0 91.0 65.0 80.0 82.0 19.0 21.0 32.0 10 40.3 46.9 70.0 85.0 87.0 57.0 72.0 74.0 19.0 21.0 28.0 16 36.2 42.9 68.0 83.0 85.0 52.9 67.9 69.9 18.0 20.0 26.0 20 34.2 40.9 67.0 82.0 84.0 51.0 66.0 68.0 17.5 19.5 25.0 31.25 30.4 37.0 65.1 80.1 82.1 47.1 62.1 64.1 16.5 18.5 23.1 62.5 24.3 31.0 62.0 77.0 79.0 41.1 56.1 58.1 14.0 16.0 20.0 100 20.3 26.9 60.0 75.0 77.0 37.0 52.0 54.0 12.0 14.0 18.0 155 16.5 23.1 57.1 72.1 74.1 33.2 48.2 50.2 10.1 12.1 16.1 200 14.2 20.9 55.5 70.5 72.5 31.0 46.0 48.0 9.0 11.0 15.0 250 12.3 19.0 54.0 69.0 71.0 29.0 44.0 46.0 8.0 10.0 14.0 300 10.7 17.4 52.8 67.8 69.8 27.5 42.5 44.5 8.0 10.0 13.2 500 6.3 13.0 49.5 64.5 66.5 23.0 38.0 40.0 8.0 10.0 11.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA 03/12/10 - http://www.nexans.co.uk Page 68 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Cable • • • • Unshielded construction Complies to the latest Category 6 standards Central cross maintains geometry and performance Supports Class E applications up to 250 MHz. Description Application The Nexans Essential-6 cables are manufactured and tested to the latest Category 6 specications. They are compatible with the complete Essential-6 modular and PCB connectivity range. When the cable is installed in conjunction with Essential-6 outlets and patch panels, a 25 year Class E Link Certicate can be obtained from the Nexans website. Design The conductors are 24 AWG solid copper wires complying with IEC 60228. The PE central cross ller keeps the pairs in place and reduces the risks of losing performance when bending the cable. The cable is available with a Light Grey PVC or an Orange LSZH outer jacket. Performance Nexans Essential-6 cables are compliant with the requirements of the TIA 568B.2-1 and ISO/IEC 11801:2002. Installation Thanks to their small nominal outer diameter, the Essential-6 cables are as easy to install as their Cat 5e equivalent. Standards International ISO/IEC 11801 National TIA/EIA-568-B.2 03/12/10 - http://www.nexans.co.uk Page 69 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Cable Characteristics Usage characteristics Range Product List Nexans ref. N100.161 New N100.164 New N100.166 New N100.169 New essential-6 Name Type of cable Outer sheath Essential-6 U/UTP Cat 6 LSZH 305m box U/UTP LSZH Essential-6 U/UTP Cat 6 LSZH 500m reel U/UTP LSZH Essential-6 U/UTP Cat 6 PVC 305m box U/UTP PVC Essential-6 U/UTP Cat 6 PVC 500m reel U/UTP PVC = Make to order, = Make to stock Channel Performance Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel. Frequency MHz Insertion Loss NEXT PP PS NEXT ACR PS ACR ELFEXT PSELFEXT Return Loss dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB 1 4.0 65.0 62.0 65.0 62.0 63.3 60.3 19.0 4 4.2 63.0 60.5 58.9 56.4 51.2 48.2 19.0 10 6.6 56.6 54.0 50.0 47.4 43.3 40.3 19.0 16 8.3 53.2 50.6 44.9 42.3 39.2 36.2 18.0 20 9.3 51.6 49.0 42.3 39.7 37.2 34.2 17.5 31.25 11.7 48.4 45.7 36.7 34.0 33.4 30.4 16.5 62.5 16.9 43.4 40.6 26.5 23.7 27.3 24.3 14.0 100 21.7 39.9 37.1 18.2 15.4 23.3 20.3 12.0 155 27.6 36.7 33.8 9.1 6.2 19.5 16.5 10.1 200 31.7 34.8 31.9 3.1 0.1 17.2 14.2 9.0 250 35.9 33.1 30.2 -2.8 -5.8 15.3 12.3 8.0 All values are specied at 20°C. 03/12/10 - http://www.nexans.co.uk Page 70 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Keystone Connector • • • • Complies with the latest Category 6 standards Screened and Unscreened versions Easy termination without punchdown tool Keystone format. Description Application The Nexans Essential-6 keystone connectors are manufactured and tested to the latest Category 6 specications. They support Class E applications up to 250 MHz. When installed in conjunction with Essential-6 cable and patch panels, a 25 year Class E Link Warranty can be obtained from the Nexans web site. Design The Essential-6 keystone connectors are designed to match with Essential-6 cable and patch cords and complement all Essential modular components, such as: • keystone patch panels (black and white) • keystone outlet modules (UK, US and European formats) Please follow the links on this page to view the related datasheets. The modular jack is designed for keystone footprints of 14.78mm width, 20-20.78mm height and 1.5mm wall thickness and is compatible with a variety of keystone formatted structural hardware. (Please check compatibility with Nexans before using 3rd party hardware) The Essential-6 connectors can be used with all types of Category 6 cable with solid wire from 24 to 22 AWG. Performance The Essential-6 keystone connectors are compliant with the specications of ISO/ IEC 11801 and EN 50173. Standards International ISO/IEC 11801 Installation The wire organiser guarantees fast and easy termination of the Essential-6 keystone connector without the need for a punchdown tool. An optional comfort tool (N420.567) can be used to increase the ease of installation. • • • • Fast and easy termination without punchdown tool. Wiring according to colour code T568B or T568A. Accepts 24, 23 and 22 AWG solid core cables. Fits Nexans hardware designed for keystone format 03/12/10 - http://www.nexans.co.uk Page 71 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Keystone Connector Product List Nexans ref. N420.136 New N420.126 New N420.116 Name Essential-6 Keystone Connector Screened Essential-6 Keystone Connector Screened No Rear Cover Essential-6 Keystone Connector Unscreened = Make to order, = Make to stock Channel Performance Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel. Frequency MHz Insertion Loss NEXT PP PS NEXT ACR PS ACR ELFEXT PSELFEXT Return Loss dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB 1 4.0 65.0 62.0 65.0 62.0 63.3 60.3 19.0 4 4.2 63.0 60.5 58.9 56.4 51.2 48.2 19.0 10 6.6 56.6 54.0 50.0 47.4 43.3 40.3 19.0 16 8.3 53.2 50.6 44.9 42.3 39.2 36.2 18.0 20 9.3 51.6 49.0 42.3 39.7 37.2 34.2 17.5 31.25 11.7 48.4 45.7 36.7 34.0 33.4 30.4 16.5 62.5 16.9 43.4 40.6 26.5 23.7 27.3 24.3 14.0 100 21.7 39.9 37.1 18.2 15.4 23.3 20.3 12.0 155 27.6 36.7 33.8 9.1 6.2 19.5 16.5 10.1 200 31.7 34.8 31.9 3.1 0.1 17.2 14.2 9.0 250 35.9 33.1 30.2 -2.8 -5.8 15.3 12.3 8.0 All values are specied at 20°C. 03/12/10 - http://www.nexans.co.uk Page 72 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Patch Panels • Complies to the latest Category 6 standard • Punchdown from the top or the rear side • Unshielded Description Application The Nexans Essential-6 patch panels are based on 19" frame dimensions and have 24 Category 6 RJ45 ports on 1HU. They support Class E applications up to 250 MHz. When the panels are installed in conjunction with Essential-6 cable and outlets, a 20 year Class E Link Certicate can be obtained from the Nexans eservice site. Design The Essential-6 patch panels are compatible with the complete Essential-6 range and can be used with all types of UTP Category 6 cable with solid wire from 22 to 24 AWG. The panels are available in either black or grey-white nish. Performance The Essential-6 patch panels are compliant with the specications of ISO/IEC 11801:2002. Installation • Fast and easy termination of IDC blocks by LSA+ punchdown tooling. • Colour code T568A and T568B (Product dependent). • Supplied with xings and tie-wraps. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 73 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Patch Panels Product List Nexans ref. N424.610 New N424.613 New Name Essential-6 Patch panel 1HU 24 Cat 6 ports, rear connection, black Essential-6 Patch panel 1HU 24 Cat 6 ports, top connection, black = Make to order, = Make to stock Channel Performance Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel. Frequency MHz Insertion Loss NEXT PP PS NEXT ACR PS ACR ELFEXT PSELFEXT Return Loss dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB 1 4.0 65.0 62.0 65.0 62.0 63.3 60.3 19.0 4 4.2 63.0 60.5 58.9 56.4 51.2 48.2 19.0 10 6.6 56.6 54.0 50.0 47.4 43.3 40.3 19.0 16 8.3 53.2 50.6 44.9 42.3 39.2 36.2 18.0 20 9.3 51.6 49.0 42.3 39.7 37.2 34.2 17.5 31.25 11.7 48.4 45.7 36.7 34.0 33.4 30.4 16.5 62.5 16.9 43.4 40.6 26.5 23.7 27.3 24.3 14.0 100 21.7 39.9 37.1 18.2 15.4 23.3 20.3 12.0 155 27.6 36.7 33.8 9.1 6.2 19.5 16.5 10.1 200 31.7 34.8 31.9 3.1 0.1 17.2 14.2 9.0 250 35.9 33.1 30.2 -2.8 -5.8 15.3 12.3 8.0 All values are specied at 20°C. 03/12/10 - http://www.nexans.co.uk Page 74 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Outlet Modules • • • • • • Complies to the latest Category 6 standards Includes 25x50, LJ6C and 50x50 triple modules Unshielded LSA+ termination UK white Fits in all Nexans UK structural hardware Description Application The Nexans Essential-6 unshielded outlet modules are manufactured and tested to the latest Category 6 specications. They support Class E applications up to 250 MHz. When installed in conjunction with Essential-6 cable and patch panels, a 25 year Class E Link Certicate can be obtained from the Nexans e-service site. Design The Essential-6 outlet modules are compatible with the complete Essential-6 range and t into all Nexans UK structural hardware. They can be used with all types of UTP Category 6 cable with solid wire from 22 to 24 AWG. The spring shuttered modules come in glossy white nish, matching with most British style structural hardware. They are available in different versions: • • • • single module 25x50mm single module 25x50mm - low prole triple module 50x50mm LJ6C module 25x37mm The modules are equipped with transparent label holders tted with a blank paper label for customised port identication. Performance The Essential-6 outlet modules are compliant with the specications of ISO/IEC 11801: 2002. Installation Standards • • • • • • International ISO/IEC 11801 Fast and easy termination by LSA+ punch-down tooling. Wiring according to colour code T568B. Centrally positioned tie wrap bridges ensure cable strain relief. Supplied with tie wraps. Labelling windows included. Fits in all Nexans UK structural hardware 03/12/10 - http://www.nexans.co.uk Page 75 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Outlet Modules Product List Nexans ref. N424.623 N424.621 N424.620 New N424.622 To be removed Name Essential-6 LJ6C outlet module 25x39.5mm Essential-6 single outlet module 25x50mm Essential-6 single outlet module 25x50mm - Low Prole Essential-6 triple outlet module 50x50mm = Make to order, = Make to stock Channel Performance Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel. Frequency MHz Insertion Loss NEXT PP PS NEXT ACR PS ACR ELFEXT PSELFEXT Return Loss dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB 1 4.0 65.0 62.0 65.0 62.0 63.3 60.3 19.0 4 4.2 63.0 60.5 58.9 56.4 51.2 48.2 19.0 10 6.6 56.6 54.0 50.0 47.4 43.3 40.3 19.0 16 8.3 53.2 50.6 44.9 42.3 39.2 36.2 18.0 20 9.3 51.6 49.0 42.3 39.7 37.2 34.2 17.5 31.25 11.7 48.4 45.7 36.7 34.0 33.4 30.4 16.5 62.5 16.9 43.4 40.6 26.5 23.7 27.3 24.3 14.0 100 21.7 39.9 37.1 18.2 15.4 23.3 20.3 12.0 155 27.6 36.7 33.8 9.1 6.2 19.5 16.5 10.1 200 31.7 34.8 31.9 3.1 0.1 17.2 14.2 9.0 250 35.9 33.1 30.2 -2.8 -5.8 15.3 12.3 8.0 All values are specied at 20°C. 03/12/10 - http://www.nexans.co.uk Page 76 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Patch Cords • • • • • Comply with latest Category 6 standards Screened and unscreened Light grey PVC Light grey slimline boot with bend relief 1, 2, 3 and 5m lengths Description Application The Nexans Essential-6 patch cords are manufactured and tested to the latest Category 6 specications and support Class E applications up to 250 MHz. They are matched with the complete Essential-6 range in order to deliver a full end-toend Class E Channel. Design The Essential-6 patch cords contain a central PE cross member, keeping the pairs in place and reducing the risk of losing performance when bending the cords. Available in standard lengths of 1, 2, 3 and 5m, each cord is individually bagged and carries a traceability code. Performance The Essential-6 cords are compliant with the specications of ISO/IEC 11801 and EN 50173. Installation Thanks to their small outer diameter, the Essential-6 cords are as easy to install and manage in a rack as their Cat 5e equivalent. Standards International ISO/IEC 11801 Flame retardant IEC 60332-1 03/12/10 - http://www.nexans.co.uk Page 77 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Patch Cords Characteristics Electrical characteristics Characteristic impedance Usage characteristics Range Flame retardant Product List Nexans ref. N101.12ECGG New N101.12EEGG New N101.12EFGG New N101.12EHGG New N101.21ECOO New N101.21EEOO New N101.21EFOO New N101.21EHOO New N101.11ECGG New N101.11EEGG New N101.11EFGG New N101.11EHGG New 100 Ohm essential-6 IEC 60332-1 =Make to order, =Make to stock Screen Length (m) Outer sheath Colour Name Essential-6 Patch Cord FTP Cat 6 PVC Grey 1m FTP 1 PVC Light grey Essential-6 Patch Cord FTP Cat 6 PVC Grey 2m FTP 2 PVC Light grey Essential-6 Patch Cord FTP Cat 6 PVC Grey 3m FTP 3 PVC Light grey Essential-6 Patch Cord FTP Cat 6 PVC Grey 5m FTP 5 PVC Light grey Essential-6 Patch Cord UTP Cat 6 LSZH Orange 1m UTP 1 LSZH Orange Essential-6 Patch Cord UTP Cat 6 LSZH Orange 2m UTP 2 LSZH Orange Essential-6 Patch Cord UTP Cat 6 LSZH Orange 3m UTP 3 LSZH Orange Essential-6 Patch Cord UTP Cat 6 LSZH Orange 5m UTP 5 LSZH Orange Essential-6 Patch Cord UTP Cat 6 PVC Grey 1m UTP 1 PVC Light grey Essential-6 Patch Cord UTP Cat 6 PVC Grey 2m UTP 2 PVC Light grey Essential-6 Patch Cord UTP Cat 6 PVC Grey 3m UTP 3 PVC Light grey Essential-6 Patch Cord UTP Cat 6 PVC Grey 5m UTP 5 PVC Light grey = Make to order, = Make to stock Channel Performance Values given for 2-connector channel, built with Essential-6 cable, outlet and patch panel. Frequency MHz Insertion Loss NEXT PP PS NEXT ACR PS ACR ELFEXT PSELFEXT Return Loss dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB 1 4.0 65.0 62.0 65.0 62.0 63.3 60.3 19.0 4 4.2 63.0 60.5 58.9 56.4 51.2 48.2 19.0 10 6.6 56.6 54.0 50.0 47.4 43.3 40.3 19.0 16 8.3 53.2 50.6 44.9 42.3 39.2 36.2 18.0 20 9.3 51.6 49.0 42.3 39.7 37.2 34.2 17.5 31.25 11.7 48.4 45.7 36.7 34.0 33.4 30.4 16.5 62.5 16.9 43.4 40.6 26.5 23.7 27.3 24.3 14.0 100 21.7 39.9 37.1 18.2 15.4 23.3 20.3 12.0 155 27.6 36.7 33.8 9.1 6.2 19.5 16.5 10.1 200 31.7 34.8 31.9 3.1 0.1 17.2 14.2 9.0 250 35.9 33.1 30.2 -2.8 -5.8 15.3 12.3 8.0 03/12/10 - http://www.nexans.co.uk Page 78 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-6 Patch Cords All values are specied at 20°C. 03/12/10 - http://www.nexans.co.uk Page 79 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Category 7 / 7A LANmark-7 is the highest performance standards compliant, copper solution available in the market. This Category 7 / Class F solution provides backwards compatible performance beyond 600MHz and features the revolutionary GG45 connector. Recommended uses: • Very long lifetime needs (>15years) • Composite analogue & high speed digital data • Multiple service applications (voice, data, video using different pairs in the same cable) • Very high electromagnetic noise environments • Installations where the relacement cost is very high (e.g. ships etc) 03/12/10 - http://www.nexans.co.uk Page 80 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Cable • • • • Exceeds Category 7 using 4 individually screened pairs Optimised for use with LANmark-7 GG45 connector Small outer diameter Easy to install due to a tight foil construction Description Description LANmark-7 cable is a 4pr S/FTP with individual pair foils and an overall braid offering superior performance in terms of ACR. It is fully compliant with the Category 7 standards and when installed together with the GG45 LANmark-7 connector as a system is guaranteed to exceed all channel requirements in all conguration scenarios (up to 4-connector channels). Application LANmark-7 will support all current and planned data applications developed for cabling up to Class F. • • • • • • All Ethernet applications including 1000Base-T 1000Base-TX 10GBase-T CATV up to 862MHz Any future Class F application Installation Ease of Installation is one of the unique features of LANmark-7 cable. Extra attention has been paid to ensure screen coverage is maintained both during and after installation. The cable has been designed specically to offer both optimum performance and ease of termination when used in conjunction with the LANmark-7 GG45 connector. 03/12/10 - http://www.nexans.co.uk Standards International EN 50173; EN 50288-4-1; ISO/IEC 11801; ISO/ IEC 61156-5 Page 81 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Cable Characteristics Transmission characteristics Velocity of propagation Product List Nexans ref. N100.376 N100.365 New N100.367 New 80.0 % =Make to order, =Make to stock Type of cable Category S/FTP Cat. 7 Name LANmark-7 Lloyd's S/FTP Cat 7 23 AWG LSZH Blue 500m Reel LANmark-7 S/FTP Cat 7 600MHz 23 AWG LSZH Orange 1000m Reel S/FTP Cat. 7 LANmark-7 S/FTP Cat 7 600MHz Dual 2x23AWG LSZH Orange 500m Reel S/FTP Shotgun = Make to order, Cat. 7 = Make to stock Electrical Performance LANmark-7 600 S/FTP Cable Electrical Performance LANmark-7 600 S/FTP Cable Attenuation Frequency (dB/100m) (MHz) NEXT ACR PS-NEXT ACR-F PS-ACR-F (in dB) (in dB) (in dB) (in dB) (in dB) Min. Typ. Min. Typ. Min. Typ. Min. Typ. Min. Return Loss (in dB) Max. Typ. Typ. Min. Typ. 1.00 4.0 1.8 75.0 100.0 71.0 98.2 72.0 98.0 75.0 98.0 75.0 96.0 20.0 4.00 4.0 3.5 75.0 100.0 71.0 96.5 72.0 98.0 75.0 98.0 75.0 96.0 23.0 26.0 10.00 5.9 5.5 75.0 100.0 69.1 94.5 72.0 98.0 75.0 98.0 72.3 96.0 25.0 28.0 16.00 7.4 6.8 75.0 100.0 67.6 93.2 72.0 98.0 71.2 96.0 68.2 94.0 25.0 28.0 20.00 8.3 7.7 75.0 100.0 66.7 92.3 72.0 98.0 69.3 94.0 66.3 92.0 25.0 28.0 31.25 10.4 9.6 75.0 100.0 64.6 90.4 72.0 98.0 65.4 90.0 62.4 88.0 23.6 26.0 62.50 14.9 14.0 75.0 100.0 60.1 86.0 72.0 98.0 59.4 84.0 56.4 82.0 21.5 25.0 100.00 19.0 17.7 72.4 100.0 53.4 82.3 69.4 98.0 55.3 75.0 52.3 73.0 20.1 24.0 155.00 24.0 22.8 69.5 96.0 45.6 73.2 66.5 93.0 51.5 70.0 48.5 68.0 18.8 23.0 250.00 31.0 29.0 66.4 94.0 35.5 65.0 63.4 91.0 47.3 66.0 44.3 64.0 17.3 22.0 300.00 34.2 32.1 65.2 92.0 31.1 59.9 62.2 88.0 45.8 54.0 42.8 52.0 17.3 20.0 600.00 50.1 45.5 60.7 90.0 10.6 44.5 57.7 86.0 39.7 54.0 36.7 52.0 17.3 20.0 all values are specied at 20°C 03/12/10 - http://www.nexans.co.uk Page 82 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 GG45 Connector LANmark-7 GG45 • • • • • • • • High speed ‘2 in 1’ Multimedia Connector Supports data applications up to 600 MHz Class F Supports CATV VHF and UHF up to 1000MHz Backwards compatible Switch Inside Compatible with ISO 11801 (enterprise cabling) Compatible with ISO 15018 (residential cabling) Fits in all Nexans modular Snap-In structural hardware Description Description LANmark-7 GG45 is a standardised High Speed ‘2 in 1’ Snap-In Connector, which contains a full Cat 6 (RJ45) Interface as well as a full Cat 7 Interface, using additional contacts for the 600 MHz transmission. LANmark-7 offers uniquely backwards compatible services realised through an incorporated switch, which activates a maximum of 8 out of 12 contacts. For 100/250 MHz transmission performance, the upper 8 RJ45 contacts are used, for 600 MHz the 8 contacts in the extreme corners are used. The LANmark-7 GG45 Snap-In Connector is part of the Nexans modular Snap-In system and ts in all structural hardware designed for this range. It is a fullscreened connector with 360° EMC protection. 4 versions of LANmark-7 GG45 are available: one for solid cables, one for stranded cables, a UL version and a Heavy Duty connector for harsh environments. The version of GG45 for stranded wire is especially made for networks, which use 3/4 Connector Links and so called Consolidation Points to achieve higher exibility. GG45 for stranded wire can terminate single ended exible patch cords at those Consolidation Points. An optional adapter clip can be added to t the outer dimensions of the international well-known keystone format. Standards Application International ISO/IEC 11801 LANmark-7 GG45 supports all data applications dened for Cat 5, Cat 5E, Cat 6 and Cat 7 such as 10BaseT, 100BaseT, Gigabit Ethernet, 1000BaseTX, 1GBaseTX2 over Class F, 1GBaseTX4 over Class F, 10GBaseT according IEEE802.3.AN, 155 ATM, 622 ATM, 1G ATM (CB1G) ..... . Performance The LANmark-7 GG45 Snap-In Connector has been designed to reach the highest performance in Cat 6, Cat 7 and broadcast applications (as for example ISO 15018 residential cabling). It has outstanding performance for attenuation (insertion loss), NEXT/FEXT, Power Sum NEXT/FEXT and RETURN LOSS. A metal cross inside the connector ensures the high NEXT performance in Cat 6 and Cat 7 mode. Excellent Return Loss Values ensure that LANmark-7 GG45 in addition to all Data applications is best suited to support CATV signals up to 1000 MHz. Product List Nexans ref. N420.730 N420.731 =Make to order, =Make to stock Name LANmark-7 GG45 12C Snap-In Connector Cat 7 600MHz Screened LANmark-7 GG45 12C Snap-In Connector Cat 7 600MHz Screened for stranded wire = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 83 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 GG45 Connector Selling delivery information Guarantees The LANmark-7 GG45 Snap-In Connector is fully compliant with the current ISO Cat 6 and Cat 7 standard and exceeds all parameters with substantial headroom. When combined with LANmark Cat 6 or Cat 7 Cables and Patch Cords a full 25 year Class E and F Channel Warranty can be obtained. Installation The LANmark-7 GG45 Snap-In connector is designed to be terminated without punch down tools. For fast and easy installation of large volumes, an optional Comfort Tool can be used. • • • • Versions for solid cable: accepts 24, 23 and 22 AWG cable Version for stranded cable: accepts 26 AWG ex cable Fast termination of cable using Nexans wire organiser Colour code : TSB568A and TSB568B 03/12/10 - http://www.nexans.co.uk Page 84 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] GG45 8C PCB jack LANmark-7 GG45 • • • • • Right angled Cat 7A PCB jack up to 1500 MHz to be used in active equipment or patch panels UL94-V0 plastic components RoHS compliant Wave solder compatible. Description Please refer to the datasheet of N420.738 for more detailed information and performance tables. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 85 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] GG45 8C PCB jack Characteristics Construction characteristics Colour Screen Connector type Dimensional characteristics Height Width Depth Usage characteristics Component function Product List Nexans ref. N420.738 New Black Yes Female 13.5 mm 15.24 mm 21.84 mm Connector Name GG45 Right angle 8 contact jack for PCB mount Category Range Cat. 7A LANmark-7A = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 86 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Patch Cords Nexans Cat 7 Patch Cords • • • • • High speed multimedia patch cord 600 MHz according IEC61076-3-110 Allow full 4-connector Class F channels Compatible with ISO 11801 (Ofce environment) Compatible with ISO 15018 standard (Residential environment) Description Application Nexans LANmark-7 patch cords with GG45 non switched plugs enable a GG45 permanent link to be used in 600 MHz mode. The protruding part on the plug activates the switch within the GG45 jack and terminates the not used contacts of RJ45 to ground. Using the contacts in the extreme outer corners of the RJ45 interface for transmission, excellent NEXT and Return Loss performance are achieved. Nexans LANmark-7 patch cords maximise the full performance of the channel and will exceed the requirements of the ISO 4 connector model. This provides improved data throughput up to 600 MHz and allows for the inclusion of additional patching or Consolidation Points for maximum system exibility and all future data applications according ISO 11801. • High Speed Multimedia patch cords • Screened • 2 x GG45 4-pair, non backwards compatible plugs Guarantees • • • • Reliable connections over the lifetime of the cabling system. Compatible with IEC 61076-3-110 Compatible with Class F standard (ISO 11801) Compatible with Residential standard (ISO 15018) for BCT applications Standards International ISO/IEC 11801 Installation • Rugged construction - high connector retention force due to moulded connectors - external strain relief - self-latching, high reliability GG45 (IEC61076-3-110) screened connectors - sidebars on the plug avoid errors by using the patch cord for RJ45 jacks • A Low Smoke Zero Halogen - Flame Retardant jacket is standard • Orange is standard, different colors are available on request, subject to quantity and availability • 1, 2, 3 and 5m are standard lengths, others lengths are available on demand Fire retardant IEC 60332 Part 1 03/12/10 - http://www.nexans.co.uk Page 87 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Patch Cords Characteristics Construction characteristics Outer sheath Colour Electrical characteristics Characteristic impedance Usage characteristics Fire retardant LSZH-FR Orange 100 Ohm IEC 60332 Part 1 Product List Nexans ref. Name N900.679 N101.239EO N101.239FO N101.239HO N101.269OO =Make to order, =Make to stock Mechanical durability/ Length Nominal outer Range matings (m) diameter (mm) LANmark-7 Measurement Cord Cat 7 GG45 4P/GG45 4P LSZH-FR SCR 2 M ORANGE LANmark-7 Patch Cord Cat 7 GG45 4P/GG45 4P LSZH FR SCR 2 M ORANGE LANmark-7 Patch Cord Cat 7 GG45 4P/GG45 4P LSZH-FR SCR 3 M ORANGE LANmark-7 Patch Cord Cat 7 GG45 4P/GG45 4P LSZH-FR SCR 5 M ORANGE LANmark-7 Single End Cord Cat 7 GG45 4P LSZH-FR SCR 10 M ORANGE 1000 2 6.35 LANmark-7 750 2 6.35 LANmark-7 750 3 6.35 LANmark-7 750 5 6.35 LANmark-7 750 10 6.35 LANmark-7 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 88 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Splitter Cords • • • • Patch cords to allow application sharing with GG45 Up to 4 applications simultaneously Compatible with ISO 11801 Compatible with ISO 15018 draft Description Application LANmark-7 Splitter cords allow to run multiple applications at the same time using only 1 GG45 permanent link. LANmark-7 cable provides 4 individually shielded cable pairs . The GG45 Connector maintains the individual shields due to its internal metal cross and creates 4 completely shielded end to end communications channels, which can be used by different applications simultaneously. The LANmark-7 splitter cords allow to address each communication channel individually. Many applications do not use all 4-pairs provided by the cable. Analogue telephony and CATV for example need only 1 pair, many data protocols like Ethernet and Fast Ethernet use 2 pairs. Broadband Applications supported LANmark-7 systems support CATV/CCTV applications and comply with the requirement for BCT in the ISO15018 Draft for Home Applications. Each of the 4 communication channels supports the CATV/CCTV applications up to 1000MHZ. Up to the maximum of 4 pairs different combinations are supported: • 4 services : eg. 4 x 1 pair applications such as voice, fax, CATV/CCTV • 3 services: eg. 2 x 1 pair applications plus 1 x 2 application such as Ethernet or Fast Ethernet • 2 services: eg. 2 x 2 pair applications • 1 service: eg. 1 x 4 pair application such as Gigabit Ethernet Standards International ISO/IEC 11801 Description The patch cords always have 1 GG45 Plug on the wall outlet side and multiple connectors on the user side. The GG45 Plugs terminates up to 3 cables, held together by a molded boot. On the user side the patch cords use standard RJ45 or RJ11 connectors. Guarantees • Reliable connections with LANmark-7 GG45 and User Terminals • up to 750 insertions • Compatible with IEC 61076-3-110 and IEC 60603-7 series Properties • Grey Color Flame retardant IEC 60332-1 03/12/10 - http://www.nexans.co.uk Page 89 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7 Splitter Cords Characteristics Construction characteristics Outer sheath Sheath colour Electrical characteristics Characteristic impedance Usage characteristics Mechanical durability/matings Range Flame retardant Product List Nexans ref. N101.2B9CG New N101.2B9EG New N101.2B9FG New N101.2B9HG New N101.2A9CG New N101.2A9EG New N101.2A9FG New N101.2A9HG New LSZH-FR Light grey 100 Ohm 750 LANmark-7 IEC 60332-1 =Make to order, Name =Make to stock Length (m) Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 1m LSZH Grey 1 Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 2m LSZH Grey 2 Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 3m LSZH Grey 3 Splitter Patch Cord GG45 - 1xEthernet RJ45 - 2xVoiceRJ11 Screened 5m LSZH Grey 5 Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 1m LSZH Grey 1 Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 2m LSZH Grey 2 Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 3m LSZH Grey 3 Splitter Patch Cord GG45 - 2xEthernet RJ45 Screened 5m LSZH Grey 5 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 90 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A Cable • • • • • Exceeds Category 7A in terms of ACR and Frequency Range Suitable for channels with capacity above 40GBps over 100m Superior Performance with positive ACR over the full frequency range Optimised for use with LANmark-7A GG45 connector Easy to install with Cat 7 connectivity through special foil construction Description Description LANmark-7A is a 4 pair S/FTP cable with individual pair foils and an overall braid offering superior performance up to 1200MHz. It is fully compliant with the new Category 7A standard and offers even large headroom above the Cat 7A requirement. Due to this excellent electrical performance and positive ACR up to 1000 / 1200MHz the cable is suited for transmission channels with a capacity of >40Gbps over 100m. Application LANmark-7A is the highest performing standardised cabling solution in the market and will support all current data applications and all planned applications using cabling up to Class FA (see discussions at IEEE about 40/100Gbps). • • • • • • • All Ethernet applications including 10/100/1000Base-T 1000Base-TX 10GBase-T CaTV up to 862MHz Cable sharing applications including CATV Any future Class FA application Standards International EN 50173; EN 50288-4-1; ISO/IEC 11801; ISO/ IEC 61156-5 Installation Ease of Installation is one of the main features of the LANmark-7A cable. Extra attention has been paid to ensure that the screen coverage is maintained and foils do not open during installation. The cable has been specially designed to be used in conjunction with the LANmark-7A GG45 12C connector. 03/12/10 - http://www.nexans.co.uk Page 91 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A GG45 Connector LANmark-7A GG45 • • • • • • • First RJ45-compatible Cat 7A connector using Nexans unique GG45 interface Able to support future 40Gigabit Ethernet application Able to provide Shannon Capacity of 50Gbps over 100m Full Class FA channel compliancy according to ISO11801 Amendment 1 Fully screened for Alien Crosstalk Immunity ”2 in 1” Connector using 12 contacts to run 2 separate transmission modes Compatible with all Snap-In panels and outlets Description Description LANmark-7A GG45 is a screened RJ45-compatible cable jack specied up to 1000MHz. It is designed specically to support the high frequencies required for applications beyond 10 Gigabit Ethernet. Combined with LANmark7A Cable and Patch Cords, LANmark-7A GG45 has double the frequency range and half of the crosstalk compared to Cat6A and provides excellent transmission capacity up to 50Gbps over 100m (4-times of Cat6A). LANmark-7A GG45 uses 12 contacts: 8 contacts for the 1200MHz transmission (GG-mode) and 4 additional contacts to ensure RJ45 compatibility (RJ Mode). Thanks to its 360° screening and a fully closed rear cover, the connector allows excellent coupling attenuation and ensures immunity from alien crosstalk and other external interference. The LANmark-7A GG45 connector ts in all structural hardware designed for the Snap-In Connectors and can be used in all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO). Applications • • • • • • • • • • 10Base-T Ethernet 100Base-TX Fast Ethernet 1000Base-TX Gigabit Ethernet 10GBase-T 10 Gigabit Ethernet IEEE 802.3 155 Mbit ATM 1.2 Gbit ATM CATV up to 862MHz all future Cat 6A and Class EA applications all future Cat 7 and Class F applications all future Cat 7 and Class FA applications Standards International EN 50173-1; IEC 60603-7-5; ISO/IEC 11801 Performance The LANmark-7A GG45 12C Snap-In Connector is the rst RJ45 compatible which meets the stringent requirements of Cat 7A up to 1000MHz. It has outstanding performance for Insertion Loss, Return Loss, NEXT/FEXT, Power Sum NEXT/FEXT, and especially Alien Crosstalk. When used in combination with Nexans LANmark-7A cables and LANmark-7A patch cords, the four-connector channel meets Class FA requirements as dened in ISO/IEC11801 amendment 1. Installation The LANmark-7A GG45 12C Snap-In Connector makes use of Nexans wire organiser and is therefore very easy and fast to terminate. Using the Nexans patented Easy Termination Tool for GG45 the termination of GG45 is fool-proof and very reliable. A stranded version is available to allow the use of exible stranded cable in cross connects or consolidation points. 03/12/10 - http://www.nexans.co.uk Page 92 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A GG45 Connector • • • • • • • • Fast termination with exclusive wire organizer Colour code : T568A &T568B 360° EMC protection Accepts solid wire from 22 to 24 AWG Stranded version available for consolidation point Snap-in format ts in all Nexans structural hardware 2 possibilities to terminate the drain wire : on the housing or on the rear cover Can be turned into keystone format using additional adapter Guarantees The LANmark-7A GG45 12C Snap-In Connector is covered by the guarantee as described in “The General Terms and Conditions of Sales”. When installed in combination with other LANmark-7A components, a 25 years channel warranty can be obtained, covering full Cat 7A/Class FA compliance. 03/12/10 - http://www.nexans.co.uk Page 93 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A GG45 Connector Product List Nexans ref. N420.735 N420.736 Name Height (mm) Width (mm) Depth (mm) 19.5 17 41.4 19.5 17 41.4 LANmark-7A GG45 12C Snap-In Connector Cat 7A 1000MHz Screened LANmark-7A GG45 12C Snap-In Connector Cat 7A 1000MHz Screened for stranded wire = Make to order, = Make to stock Electrical Performance LANmark-7A Typical Data given for Worst Case 4-Connector Channel Congurations Attenuation NEXT pp ACR-F RL Coupling Att. PSANEXT PSAFEXT Frequency (in dB) (in dB) (in dB) (in dB) (in dB) (in dB) (in dB) (in MHz) Max Typical Min Typical Min Typical Min Typical Min Typical Min Typical Min Typical 1 4.0 3.6 65.0 104.8 65.0 70.0 19.0 38.0 80.0 106.0 67.0 82.0 80.0 95.0 4 4.1 3.7 65.0 94.6 65.0 70.0 19.0 32.0 68.0 94.0 67.0 82.0 79.8 94.8 10 6.4 5.7 65.0 87.8 65.0 70.0 19.0 28.0 60.0 86.0 67.0 82.0 75.9 90.9 16 8.0 7.2 65.0 84.2 63.3 68.3 18.0 26.0 55.9 81.9 67.0 82.0 73.9 88.9 20 9.0 8.1 65.0 82.5 61.4 66.4 17.5 25.0 54.0 80.0 67.0 82.0 72.9 87.9 31.25 11.2 10.1 65.0 79.1 57.5 62.5 16.5 23.1 50.1 76.1 67.0 82.0 71.0 86.0 62.5 15.9 14.3 65.0 73.7 51.5 56.5 14.0 20.0 44.1 70.1 67.0 82.0 68.0 83.0 100 20.3 18.2 65.0 70.0 47.4 52.4 12.0 18.0 40.0 66.0 67.0 82.0 65.9 80.9 155 25.4 22.8 63.0 66.6 43.6 48.6 10.1 16.1 36.2 62.2 67.0 82.0 63.9 78.9 200 28.9 26.0 60.9 64.6 41.4 46.4 9.0 15.0 34.0 60.0 67.0 82.0 62.8 77.8 250 32.5 29.2 59.1 62.8 39.4 44.4 8.0 14.0 32.0 58.0 67.0 82.0 61.8 76.8 300 35.7 32.1 57.7 61.3 37.8 42.8 8.0 13.2 30.5 56.5 67.0 82.0 60.9 75.9 500 46.7 42.0 53.6 57.2 33.4 38.4 8.0 11.0 26.0 52.0 64.5 79.5 58.6 73.6 600 51.4 46.3 52.1 55.8 31.8 36.8 8.0 10.2 24.4 50.4 63.3 78.3 57.8 72.8 700 55.8 50.2 50.8 54.5 30.5 35.5 7.5 9.5 23.1 49.1 62.3 77.3 57.1 72.1 800 59.9 53.9 49.7 53.5 29.3 34.3 7.0 9.0 21.9 47.9 61.5 76.5 56.4 71.4 900 63.8 57.5 48.8 52.5 28.3 33.3 6.5 8.5 20.9 46.9 60.7 75.7 55.9 70.9 1000 67.6 60.8 47.9 51.6 27.4 32.4 6.0 8.0 20.0 46.0 60.0 75.0 55.4 70.4 all values are specied at 20°C 03/12/10 - http://www.nexans.co.uk Page 94 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A Patch Cord LANmark-7A GG45 Patchcords • • • • • High bandwidth patch cord for 40 Gigabit applications and beyond Runs the GG45 '2in1' Connector in its high speed GG-Mode Both Sides use GG45 8 Contact Plugs up to 1000 MHz according IEC61076-3-110 Allow full 4-connector Class FA channels Compatible with High Density requirements in Data Centres Description Description Nexans LANmark-7A patch cords with GG45 8C non-switched plugs enable a GG45 7A permanent link to be used in 1000 MHz mode. The protruding part on the plug activates the switch within the GG45 7A “2in1” jack and terminates the none used contacts of RJ45 to ground. Using the contacts in the extreme outer corners of the RJ45 interface for transmission, excellent NEXT and Return Loss performances are achieved. Nexans LANmark-7A patch cords maximise the full performance of the channel and will exceed the requirements of the ISO 4 connector model. This provides improved data throughput up to 1000 MHz and allows for the inclusion of additional patching or Consolidation Points for maximum system exibility and all future data applications according ISO 11801. • High Speed patch cords • Screened • 2 x GG45 8C 4-pair Guarantees • Reliable connections over the lifetime of the cabling system. • Compatible with IEC 61076-3-110 • Compatible with Class F and Class FA standards (ISO 11801:2008) Standards International ISO/IEC 11801 Installation • • • • • • Look and Feel of a RJ45 plug (just using different contact positions) Self-latching, high reliability GG45 (IEC61076-3-110) screened connectors Sidebars on the plug avoid errors by using the patch cord for RJ45 jacks Low Smoke Halogen Free - Flame Retardant cable jacket Orange color, different colors available on request 1, 2, 3 and 5m lengths, others lengths available on request 03/12/10 - http://www.nexans.co.uk Page 95 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-7A Patch Cord Characteristics Construction characteristics Colour Product List Nexans ref. N900.67A New N101.23AOO New N101.23ARO New N101.23AEO New N101.23AFO New N101.23AHO New Orange =Make to order, =Make to stock Name CAT7A Measurement Cord GG45 8C LSZH Orange 2m LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 10m LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 20m LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 2m LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 3m LANmark-7A Patch Cord Cat 7A 1GHz GG45 8C Screened LSZH Orange 5m = Make to order, = Make to stock Electrical Performance LANmark-7A Typical Data given for Worst Case 4-Connector Channel Congurations Attenuation NEXT pp ACR-F RL Coupling Att. PSANEXT PSAFEXT Frequency (in dB) (in dB) (in dB) (in dB) (in dB) (in dB) (in dB) (in MHz) Max Typical Min Typical Min Typical Min Typical Min Typical Min Typical Min Typical 1 4.0 3.6 65.0 104.8 65.0 70.0 19.0 38.0 80.0 106.0 67.0 82.0 80.0 95.0 4 4.1 3.7 65.0 94.6 65.0 70.0 19.0 32.0 68.0 94.0 67.0 82.0 79.8 94.8 10 6.4 5.7 65.0 87.8 65.0 70.0 19.0 28.0 60.0 86.0 67.0 82.0 75.9 90.9 16 8.0 7.2 65.0 84.2 63.3 68.3 18.0 26.0 55.9 81.9 67.0 82.0 73.9 88.9 20 9.0 8.1 65.0 82.5 61.4 66.4 17.5 25.0 54.0 80.0 67.0 82.0 72.9 87.9 31.25 11.2 10.1 65.0 79.1 57.5 62.5 16.5 23.1 50.1 76.1 67.0 82.0 71.0 86.0 62.5 15.9 14.3 65.0 73.7 51.5 56.5 14.0 20.0 44.1 70.1 67.0 82.0 68.0 83.0 100 20.3 18.2 65.0 70.0 47.4 52.4 12.0 18.0 40.0 66.0 67.0 82.0 65.9 80.9 155 25.4 22.8 63.0 66.6 43.6 48.6 10.1 16.1 36.2 62.2 67.0 82.0 63.9 78.9 200 28.9 26.0 60.9 64.6 41.4 46.4 9.0 15.0 34.0 60.0 67.0 82.0 62.8 77.8 250 32.5 29.2 59.1 62.8 39.4 44.4 8.0 14.0 32.0 58.0 67.0 82.0 61.8 76.8 300 35.7 32.1 57.7 61.3 37.8 42.8 8.0 13.2 30.5 56.5 67.0 82.0 60.9 75.9 500 46.7 42.0 53.6 57.2 33.4 38.4 8.0 11.0 26.0 52.0 64.5 79.5 58.6 73.6 600 51.4 46.3 52.1 55.8 31.8 36.8 8.0 10.2 24.4 50.4 63.3 78.3 57.8 72.8 700 55.8 50.2 50.8 54.5 30.5 35.5 7.5 9.5 23.1 49.1 62.3 77.3 57.1 72.1 800 59.9 53.9 49.7 53.5 29.3 34.3 7.0 9.0 21.9 47.9 61.5 76.5 56.4 71.4 900 63.8 57.5 48.8 52.5 28.3 33.3 6.5 8.5 20.9 46.9 60.7 75.7 55.9 70.9 1000 67.6 60.8 47.9 51.6 27.4 32.4 6.0 8.0 20.0 46.0 60.0 75.0 55.4 70.4 all values are specied at 20°C 03/12/10 - http://www.nexans.co.uk Page 96 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Modular Patch Panels 03/12/10 - http://www.nexans.co.uk Page 97 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Snap-In Patch Panels • • • • • • • Compatible with all Snap-In connectors 24 ports Sliding and Fixed versions available Clip-On mechanism Exclusive Auto-Connect Earthing system Universal design supporting Unscreened and Screened connectors Shuttered versions available Description Nexans Snap-In range of patch panels are designed to accomodate any of the Snap-In connectors in the LANmark product family (LANmark-7A, LANmark-6A, LANmark-6, and LANmark-5). The Snap-In panels feature an exclusive Clip-On system to secure the connector in the panel and to provide a simple means of earthing shielded connectors to facilitate installation. Connection of the panel to earth is acheived with a unique Auto-Connect feature removing the need for individual bonding conductors. The panels are Nexans branded and have a series of complementary cable management products such as blank panels and patch cord guides. The patch panels are designed for standard 19" enclosures, are 1U high, and support the following common features: - 24 Ports with shutters - Designed for Screened and Unscreened Snap-In connectors - Compatible with all perfomance categories of connector - Clip-On mechanism for simple earthing - Exclusive rear cable management facilities - Robust construction Standards Nexans offers three main panel versions: International Manufacturer specication - Angled Panels to support high density environments - Sliding Panels to allow quick installation and easy maintenance which feature a exible label for port numbering - Fixed Panels using screen printed numbering systems for labelling - The sliding and xed panels also have LANsense Upgradeable versions 03/12/10 - http://www.nexans.co.uk Page 98 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Snap-In Patch Panels Product List Nexans ref. N521.671 N521.675 N521.661BK N521.661 N521.663 N521.881 N521.861 N521.865 =Make to order, =Make to stock Name Angled Patch Panel 24 Snap-In Black Angled Patch Panel 24 Snap-In White Patch Panel 24 Snap-In Fixed Black Patch Panel 24 Snap-In Fixed White Patch Panel 24 Snap-In Sliding White Upgradable Patch Panel 24 Snap-In Fixed Black Upgradable Patch Panel 24 Snap-In Sliding Black Upgradable Patch Panel 24 Snap-In Sliding White = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 99 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Empty Patch Panels for Keystone Connectors • • • • • • Compatible with Nexans keystone connectors Designed for Essential-5 and -6 range 24 ports on 1HU Tie wrap strain relief Earthing and grounding features Available in black or white Description Application The modular patch panels for keystone connectors are xed panels based on 19" frame dimensions and can house up to 24 keystone connectors on 1HU. Design The patch panels are designed to accomodate 24 Nexans Essential keystone connectors. The metalwork at the back of the panel is made of unpainted steel to enable automatic earthing and the necessary grounding when using shielded cable and connectors. The painted front plate allows a neat ush mounting of the connectors. The panels have screen-printed numbering 1-24 above the ports and a labelling eld at the right end for patch panel numbering. They are available in black (N521.660BK) and in white (N521.660). Installation The Nexans keystone connectors can easily be inserted by a simple "one-click" movement, without the need for any tool. They are also easy to remove, when necessary. The integrated cable xing plate with tie wrap strain relief ensures cable management and retention. The panels are supplied with xings. Standards International ISO/IEC 11801 An optional 19" outrigger can be used for easy termination access (N500.120). 03/12/10 - http://www.nexans.co.uk Page 100 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Empty Patch Panels for Keystone Connectors Product List Nexans ref. N521.660BK N521.660 N521.660BK New N521.660 New Name Empty Patch Panel for 24 keystone connectors black Empty Patch Panel for 24 keystone connectors white Essential Patch Panel 24 Keystone Black - New Design Essential Patch Panel 24 Keystone White - New Design = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 101 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Modular Outlets 03/12/10 - http://www.nexans.co.uk Page 102 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Hardware-LANmark • • • • • • For all 45x45mm ttings. Modules, Cover Plates, Surface Box Modules include labeling and shutters. Suitable for all snap-in connectors. Angled modules for restricted depth. Easy click-in mechanism. Description Application This range of outlet mounting hardware is suitable for all 45mm ttings and includes cover plates, at & angled modules for Snap-in connectors, and surface mount boxes. For the specic information on the Snap-in connectors, refer to the corresponding data sheets. There are two different faceplates to support all environments: • The straight version • The angled version. It offers the ideal solution for cable trays and oor boxes, where depth is restricted. Shutters prevent dust entrance. Guarantees • All plastic material is UL 94V0 Standards Installation These modular outlets t into a wide range of international 45x45 covering plates and surface mount boxes. International Manufacturer specication For easy management and port identication, the outlets all include integrated labelling windows. The Snap-in connectors are inserted into the modular outlet by a simple click-in mechanism. Product List Nexans ref. N200.051 N200.050 Name LANmark EU style 45 x 45 frame ivory Width (mm) 80 LANmark EU style 45 x 45 frame white 80 LANmark EU style 45 x 45 module 2 Snap-In at white LANmark EU style 45 x 45 surface mount box N200.115 ivory LANmark EU style 45 x 45 surface mount box N200.116 white N423.520 LANmark EU style angled 45 x 45 module 1 SnapNew In white LANmark EU style angled 45 x 45 module 2 SnapN423.541N In ivory LANmark EU style angled 45 x 45 module 2 SnapN423.540N In white N423.550 45 82 82 45 =Make to order, =Make to stock Colour Height Depth (mm) (mm) Ivory 80 White RAL 80 9010 White RAL 45 9010 Ivory White RAL 9010 White RAL 9010 82 50 82 50 45 36 45 Ivory 45 36 45 White RAL 9010 45 36 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 103 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] UK Mounting Hardware for Essential To support the Essential range of products Nexans has developed a set of UK connecting hardware in Keystone format. For LANmark specic connecting hardware, please refer to "UK Mounting Hardware for LANmark". Nexans backboxes and cover plates have Euromod dimensions and are common throughout the Essential and LANmark ranges. Description • LJ6 Keystone Module LJ6C shuttered module to accommodate one Keystone connector. • 25 x 50 Keystone Module Euromod 25x50mm shuttered module to accommodate one Keystone connector. Euromod modules t Nexans single and double gang cover plates. • Single and Double Gang Cover Plates Available in at and bevelled version. • Single and Double Back Box Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 104 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] UK Mounting Hardware for Essential Product List Nexans ref. N423.635 New N423.630 New N423.650 N423.640 N424.533 N424.532 N424.023 N424.531 N424.013 N424.530 N424.103 N424.003 =Make to order, =Make to stock Name Essential 86x86 Wallplate 1 Keystone White Essential 86x86 Wallplate 2 Keystone White Essential UK style 25x50 module 1 keystone White Essential UK style LJ6C module 1 keystone White UK Back Box - Double Gang UK Back Box - Single Gang UK Cover Plate - Double Gang UK Cover Plate - Double Gang - Bevelled UK Cover Plate - Single Gang UK Cover plate - Single Gang - Bevelled UK Half Blank UK Quarter Blank = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 105 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] UK Mounting Hardware for LANmark To support the LANmark Snap-In range of products Nexans has developed a set of UK connecting hardware. The mounting hardware is common to all performance levels, from LANmark-5 through LANmark-6/6A to LANmark-7/7A. Description LJ6 Modular Outlet LJ6C dimensions (25mm x 37mm) Single Modular outlets accommodate one Snap-in connector. Supplied in UK White. shuttered 25 x 50 Modular Outlet Single Modular shuttered outlet 25mm x 50mm suitable to accommodate one Snap-in connector. Supplied in UK White. Modular Outlet ts Nexans single and double gang cover plates. Single and Double Cover Plates Single and double gang cover plates supplied in UK White. Flat and beveled version is available. Single and Double back box Standards Single and double gang back box supplied in UK White. International ISO/IEC 11801 Angled modular outlet The angled modular shuttered outlet 50x50mm can accomodate 2 snap-in connectors and is supplied in UK White. It can be used to create horizontal or vertical quad outlets. 03/12/10 - http://www.nexans.co.uk Page 106 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] UK Mounting Hardware for LANmark Product List Nexans ref. N423.861 New N423.862 New N424.203 N424.113 N424.204N New N423.540U N424.533 New N424.532 New N424.023 N424.531 New N424.013 N424.530 New N424.103 N424.213 N424.003 =Make to order, =Make to stock Name LANmark 86x86 Wallplate 1 Snap-In White LANmark 86x86 Wallplate 2 Snap-In White LJ6C Angled Module UK 25x50 Flat Module for Snap-ins UK Angled 25x50 Module for 1 snap-in UK Angled Module for 2 snap-ins UK Back Box - Double Gang UK Back Box - Single Gang UK Cover Plate - Double Gang UK Cover Plate - Double Gang - Bevelled UK Cover Plate - Single Gang UK Cover plate - Single Gang - Bevelled UK Half Blank UK LJ6C Flat Module for snap-ins UK Quarter Blank = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 107 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] US Mounting Hardware for LANmark • • • • • • US format 45x45 and 45x60 series of Cover Plates, for up to 6 snap-in connectors Suitable for ber and copper Includes xings </> All plastic material is UL 94V0 Colour white Description Application This range of mounting hardware is suitable for US ttings and includes: • 2 types of cover plates • N422.001: 45x45mm inner format, with integrated labelling system • N423.001: 60x45mm inner format, with integrated labelling system • 20x45mm module for 2 snap-in connectors (N421.610) • 20x45mm blanking module (N420.001) Detailed information can be found on the corresponding datasheets. Guarantees • All plastic material is UL 94V0 Installation • The cover plates are all supplied with xing screws. • All modules can be inserted in the cover plates by a simple click-in mechanism. 03/12/10 - http://www.nexans.co.uk Standards International UL and CSA approval National UL 94 V0 Page 108 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] US Mounting Hardware for LANmark Product List Nexans ref. N420.001 N421.610 N422.001 N423.001 Name Width (mm) 45x20 Blanking module for US cover plate 45x20 Module for 2 Snap-in connectors for US cover plate US Cover plate for 45x45 Outlet with labelling system US Cover plate for 60x45 Outlet with labelling system 45 45 70.5 70.5 =Make to order, =Make to stock Colour Height Depth (mm) (mm) White RAL 20 26.5 9010 White RAL 20 16.5 9010 White RAL 115 14 9010 White RAL 115 14 9010 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 109 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] 3rd Party Hardware Description Nexans have a range of oorplates and adaptors designed to integrate Nexans connectivity into various 3rd party products Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 110 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] 3rd Party Hardware Product List Nexans ref. N800.305 N800.306 N423.110 N423.111 N423.120 N423.121 N423.122 N423.130 =Make to order, =Make to stock Name Function of the accessory Snap-In face plate for BTicino Living International range Adaptator Snap-In face plate for BTicino Light range Adaptator Plate for up to 6 Snap-In connectors for GES6 Ackermann oor box Floor Plates Plate for up to 9 Snap-In connectors for GES9 Ackermann oor box Floor Plates Plate (left part) for up to 6 Snap-In connectors for GB2 Electraplan oor box Floor Plates Plate (right part) for up to 6 Snap-In connectors for GB2 Electraplan oor box Floor Plates Plate for up to 9 Snap-In connectors for GB3 Electraplan oor box Floor Plates Plate for up to 9 Snap-In connectors for GE12 RK5 Obo Bettermann oor Floor Plates box = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 111 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] European Mounting Hardware for Essential Keystone • • • • European mounting hardware in keystone format Designed for Essential-5 and -6 keystone range Supplied in glossy white nish Also available in UK and US format. Description To support the Essential-5 and -6 Keystone range, Nexans has developed specic mounting hardware in keystone format. Please refer to the specic datasheets for keystone modules, frames and blanks. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 112 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] European Mounting Hardware for Essential Keystone Product List Nexans ref. N423.645 N424.102 N200.645 Name Essential EU style 22.5 x 45 module 1 Keystone white Essential EU style 22.5x45 blank module white Essential EU style 45x45 frame white = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 113 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] US Mounting Hardware for Essential • • • • • US mounting hardware in keystone format Designed for Essential-5 and -6 keystone range Supplied in textured white nish Equipped with labelling windows Screws included Description To support the Essential Keystone range Nexans has developed specic mounting hardware in keystone format in European, UK and US style. Please refer to the related product datasheets for the different available modules, frames and blanks in various country specic versions. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 114 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] US Mounting Hardware for Essential Product List Nexans ref. N423.622 New N423.624 New Name Essential US style Wallplate 2 Keystone Single Gang White Essential US style Wallplate 4 Keystone Single Gang White = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 115 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice grade The Nexans Voice ange includes Voice grade cables and IDC connectivity and is used to integrate telephony applications into a LAN infrastructure. 03/12/10 - http://www.nexans.co.uk Page 116 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Cables • 25pr, 50pr, or 100pr • Suitable for voice and low grade data • Category 3 and Category 5 compliant Description Voice grade cables are used to integrate telephony applications in the backbone of a LAN infrastructure. They are multipair twisted pair cables and exist in Category 3 and Category 5 performance levels. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 117 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Cables Product List Nexans ref. Name N100.819FR N100.809N N100.M02 N100.M01 N100.808N N100.M04 Number of pairs Voice F/UTP 100 pair AWG24 LSZH Grey 250m reel (LYst) Voice U/UTP 100 pair AWG24 Cat 3 PVC Grey 500m reel Voice U/UTP 25 pair AWG24 Cat 5 LSZH Orange 1000m reel Voice U/UTP 25 pair AWG24 Cat 5 PVC Grey 1000m reel Voice U/UTP 50 pair AWG24 Cat 3 PVC Grey 500m reel Voice U/UTP 50 pair AWG24 Cat 5 LSZH Orange 500m reel =Make to order, =Make to stock Outer Type of Category sheath cable 100 LSZH F/UTP Cat. 5 100 PVC U/UTP Cat. 3 25 LSZH U/UTP Cat. 5 25 PVC U/UTP Cat. 5 50 PVC U/UTP Cat. 3 50 LSZH U/UTP Cat. 5 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 118 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] IDC connectivity and accessories Complete range of LSA+ voice connectivity and accessories Description Nexans offers a complete range of voice IDC module and accessories in order to build a voice backbone in any installation. Nexans uses the LSA+ type connectivity. The Nexans Voice range includes : • • • • • • • • • IDC connection modules 19" 3 HU frame 3HU patch guide Marking cap Open contact marking strip Surge arrestor and protection magazine Patch Cords Voice MDF solution : stand alone, wall mounted or wall box Accessories and frames Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 119 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] IDC connectivity and accessories Product List Nexans ref. N102.333 N108.106 N201.001 N103.203 N102.350 N102.332 N102.310 N102.362 N102.361 N102.360 N102.321 =Make to order, =Make to stock Name 10xVoice IDC Label Holder for Module 10 Pairs 3HU Patch Guide for IDC Frame IDC 1 pair marking cap red Surge Arrestors Voice 3HU distribution frame for 15 IDC blocks Voice IDC Label Holder for Frame Voice LSA+ Disconnection Module 10 pair Voice MDF 2x26 modules wall box Voice MDF 2x74 modules stand alone (ETSI format) Voice MDF 81 modules wall mounted Voice Surge Protector Magazine for 10 Pairs empty = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 120 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Patch Panels • Hight density RJ45 panels for voice applications • Available in black and in white Description Nexans high density Voice Panels are designed to integrate voice circuits in standard structured cabling systems. • • • • • • 50 RJ45 ports on 1U Mount to standard 19" rack LSA/110 punchdown Accept multi-pair cables from 22 to 26 AWG Supplied with xings Earthing strap included Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 121 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Patch Panels Product List Nexans ref. N500.350BK New N500.350 N424.514 To be removed Name Voice Patch Panel 50 RJ45 2 pair Black Voice Patch Panel 50 RJ45 2 pair White Voice Patch Panel 50 RJ45 3 pair Black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 122 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Patch Cords • Exists in 3 different types, depending on the application • Unscreened exible PVC cable Description Application Nexans offers 3 different types of patch cords for voice applications, for both in the cabinet and in the work area: • work area cord: 1 RJ45 to 1 RJ11 (N107.001) • cabinet patch cords: • 1 RJ45 to 1 IDC - 1 pair (N108.165 and N108.166) • 1 RJ45 to 1 IDC - 2 pairs (N108.209 and N108.210) Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 123 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Voice Patch Cords Product List Nexans ref. N107.001 N108.165 N108.166 N108.209 N108.210 =Make to order, Name Voice 2 pairs Patch Cord RJ45-RJ11 Black 5m Voice 1 pair Patch Cord 100 Ohm IDC - RJ45 Grey 1,5m Voice 1 pair Patch Cord 100 Ohm IDC - RJ45 Grey 3m Voice 2 pairs Patch Cord 100 Ohm IDC - RJ45 Grey 1,5m Voice 2 pairs Patch Cord 100 Ohm IDC - RJ45 Grey 3m = Make to order, 03/12/10 - http://www.nexans.co.uk =Make to stock Length (m) 5 1.5 3 1.5 3 = Make to stock Page 124 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Tools & Accessories 03/12/10 - http://www.nexans.co.uk Page 125 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Tools Description Nexans have a complete range of tools for terminating copper systems Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 126 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Tools Product List Nexans ref. N102.107 N422.117 N422.118 N420.567 N808.6000 N808.6020 N808.6010 N420.110 N500.120 =Make to order, =Make to stock Name Tool - LSA+ IDC punchdown tool Tool - LANmark-7 Easy Termination tool Tool - Set of spare knives for LANmark-7 Easy Termination tool Tool - Universal Comfort tool for Snap-in connector Universal Termination Tool for 808 connector 360° Connector Crimp Tool for 808 connector 360° Sheath splitting tool for 808 connector Tool - Nexans cable stripper, 110 punchdown tool 19" support tray for termination = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 127 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Keystone Clips • Adaptor clips for LANmark Snap-In connectors Description Various clips to turn LANmark Snap-In connectors into Keystone format. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 128 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Keystone Clips Product List Nexans ref. N429.620 N429.625 N429.626 N429.627 New Name Metal clip for Snap-In to keystone Red clip for EVO Snap-In connector to keystone format (wall thickness 1,5-1,75 mm) Blue clip for EVO Snap-In connector to keystone format (wall thickness 2,0-2,25 mm) Yellow clip for EVO Snap-In connector to keystone format (height 19,7 mm) = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 129 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Retrofit Hoods Description A range of coloured patchcord hoods/boots that can be tted to LANconnect-5e FTP range of cords Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 130 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Retrofit Hoods Product List Nexans ref. N111.H2S N111.H2B N111.H2V N111.H2F N111.H2O N111.H2R N111.H2J =Make to order, =Make to stock Name Hood - LANconnect 5e FTP Black (Pack of 50) Hood - LANconnect 5e FTP Blue (Pack of 50) Hood - LANconnect 5e FTP Green (Pack of 50) Hood - LANconnect 5e FTP Grey (Pack of 50) Hood - LANconnect 5e FTP Orange (Pack of 50) Hood - LANconnect 5e FTP Red (Pack of 50) Hood - LANconnect 5e FTP Yellow (Pack of 50) = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 131 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Pre-terminated Copper 03/12/10 - http://www.nexans.co.uk Page 132 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Pre-Term Bundles • • • • • • • • Ideal assemblies for high density cabling and datacenters Bundles available for Jack-Jack or Jack-Plug or Plug-Plug units Bundles available for 6,12 or 24 units Cat.6, 6A, 7 or 7A perfomance supported Fully screened and compliant to Alien Crosstalk requirements Repeatable and stable level of performance Signicant reduction of cable laying time Bundles are suitable for laying but not pulling operation Description Application LANmark Pre-Term Bundles are assemblies of 6,12 or 24 pre-terminated units. These can be Jack-Jack, Jack-Plug or Plug-Plug units. These units are maintained together as a bundle though spriral wrapping every meter. LANmark Pre-Term Bundles are well suited for areas where installation time is limited. Bundles of shielded units ensure immunity from Alien Crosstalk and other external interference. Bundles of shielded units do not requied on-site testing for Alien Crosstalk since this new parameter is met by design. Performance Cat.6/Class E, Cat.6A/Class EA, Cat.7/Class F or Cat.7A/Class FA units can be bundled. Headroom and bandwidth over and above the given category requirements according to the international, european and american standards especially for NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss are guaranteed. When used in combination with LANmark patch cords of the same category the full 100m four-connector links and channels are guaranteed as well. Standards International ISO/IEC 11801:2002/ A2:2008 National TIA/EIA-568-B.2-10 Installation Nexans LANmark Pre-Term Bundles help reducing the installation time. One assembly needs to be layed instead of 6, 12 or 24 single cables. Furtermore connectors termination is simply eliminated. Connectors are mounted and tested in our factory. Nexans LANmark Pre-Term Bundles are designed to be layed and are not suitable for pulling. All structural hardware items designed for the Snap-In range can be used in all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO). • • • • • • • Fast and straigt forward installation No need for on-site termination Reduction of installation time 360° EMC protection and alien crosstalk compliance for shielded products Support the 4 connectors channel conguration Numbering on each leg (customizable) Factory tests in paper or electronic format on request Guarantees Nexans LANmark Pre-Term bundles are covered by a parts and labour warranty as described in the Nexans Certied System Warranty. When installed in combination with LANmark patch cords of the same category, a 25 year channel warranty can be obtained. 03/12/10 - http://www.nexans.co.uk Page 133 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Pre-Term Bundles Product List Nexans ref. N62A.2C21A4XA4X--New N62A.2A21B4XB4X--New N63A.4G21A6XA6X--New N63A.4C21A6XA6X--New N63A.4C21A6XXXX--New N63A.4F11A6XC6X--New N63A.4F11CA6XXXX--New N65A.4F11A6XC6X--New N68A.4C21A6XA6X--New N68A.4C21A6XXXX--New N64A.4C21A6XA6X--New N64A.4C21A6XXXX--New N64A.4F11A6XC6X--New N64A.4G21A6XA6X--New N62A.4G21A6XA6X--New N62A.4C21A6XA6X--New N62A.4C21A6XXXX--New N62A.4F11A6XC6X--New N62A.4F11C6XXXX--New N67A.4C21A6XA6X--New N64A.6H21A8XA8X--New =Make to order, =Make to stock Name LANmark-6 Pre-Term Bundle of 6 Cat 6 F1/UTP Solid LSZH Orange Screened Jack Cat 6 LANmark-6 Pre-Term Bundle of 6 Cat 6 U/UTP Solid LSZH Orange Unscreened Jack Cat 6 LANmark-6A Pre-Term Bundle of 12 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 12 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 12 Cat 6A F1/UTP Solid LSZH Orange Screened Single end Jack Cat 6A LANmark-6A Pre-Term Bundle of 12 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug LANmark-6A Pre-Term Bundle of 12 Cat 6A U/FTP Stranded LSZH Orange Screened Plug LANmark-6A Pre-Term Bundle of 16 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug LANmark-6A Pre-Term Bundle of 18 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 18 Cat 6A F1/UTP Solid LSZH Orange Screened Single end Jack Cat 6A LANmark-6A Pre-Term Bundle of 24 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 24 Cat 6A F1/UTP Solid LSZH Orange Screened Single end Jack Cat 6A LANmark-6A Pre-Term Bundle of 24 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug LANmark-6A Pre-Term Bundle of 2x12 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 6 Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 6 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Bundle of 6 Cat 6A F1/UTP Solid LSZH Orange Screened Single end Jack Cat 6A LANmark-6A Pre-Term Bundle of 6 Cat 6A U/FTP Stranded LSZH Orange Screened JackPlug LANmark-6A Pre-Term Bundle of 6 Cat 6A U/FTP Stranded LSZH Orange Screened Plug LANmark-6A Pre-Term Bundle of 8 Cat 6A F1/UTP Solid LSZH Orange Screened Jack Cat 6A LANmark-7A Pre-Term Bundle of 24 Cat 7A S/FTP Solid LSZH Orange Screened Jack Cat 7A = Make to order, = Make to stock Selling delivery information Nexans LANmark Pre-Term Bundles can be ordered in any length up to 90m. Please refer to Nexans Design Guidelines for length calculations and limitations according to the standards. Individual packaging in boxes (L <30m) or one way reel (L>30m). Customized packaging on demand. 03/12/10 - http://www.nexans.co.uk Page 134 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Pre-Term Units • • • • Pre-Term units available in Jack-Jack or Jack-Plug or Plug-Plug assemblies Cat.6, 6A, 7 or 7A perfomance supported Repeatable and stable level of performance Signicant reduction of cable laying time Description Standards International ISO/IEC 11801 Application LANmark Pre-Term pre-terminated units can be Jack-Jack, Jack-Plug or PlugPlug assemblies. LANmark Pre-Term units are well suited for areas where installation time is limited. Shielded units ensure immunity from electromagnetic interferences and do not requied on-site testing for Alien Crosstalk since this new parameter is met by design. Performance Cat.6/Class E, Cat.6A/Class EA, Cat.7/Class F or Cat.7A/Class FA units can be made. Headroom and bandwidth over and above the given category requirements according to the international, european and american standards especially for NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss are guaranteed. When used in combination with LANmark patch cords of the same category the full 100m four-connector links and channels are guaranteed as well. Installation Nexans LANmark Pre-Term Units help reducing the installation time since connectors termination is simply eliminated. Connectors are mounted and tested in our factory. Nexans LANmark Pre-Term Units are designed to be layed and are not suitable for pulling. All structural hardware items designed for the Snap-In range can be used in all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO). • • • • • • • Fast and straigt forward installation No need for on-site termination Reduction of installation time 360° EMC protection and alien crosstalk compliance for shielded products Support the 4 connectors channel conguration Numbering on each Unit (customizable) Factory tests in paper or electronic format on request Guarantees Nexans LANmark Pre-Term Units are covered by a parts and labour warranty as described in the Nexans Certied System Warranty. When installed in combination with LANmark patch cords of the same category, a 25 year channel warranty can be obtained. 03/12/10 - http://www.nexans.co.uk Page 135 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Pre-Term Units Product List Nexans ref. N61A.2C21A4XA4X--New N61B.4G21A6XA6X--New N61A.4F11A6XC6X--New Name LANmark-6 Pre-Term Cat 6 F1/UTP Solid LSZH Orange Screened Jack Cat 6 unit LANmark-6A Pre-Term 2x4 Pair Cat 6A F/FTP Solid LSZH Orange Screened Jack Cat 6A unit LANmark-6A Pre-Term Cat 6A U/FTP Stranded LSZH Orange Screened Jack-Plug Cat 6A unit = Make to order, = Make to stock Selling delivery information Nexans LANmark Pre-Term Units can be ordered in any length up to 90m. Please refer to Nexans Design Guidelines for length calculations and limitations according to the standards. Individual packaging in boxes (L <30m) or one way reel (L>30m). Customized packaging on demand. 03/12/10 - http://www.nexans.co.uk Page 136 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack • • • • • • • Ideal assemblies for 10GBase-T applications and datacenters Fully compliant to the new Category 6A and Class EA standards Guaranteed performance in 2, 3 or 4 connectors channels up to 500MHz Very short distances for datacenters supported Fully screened and compliant to Alien Crosstalk requirements Enable fast installation and eliminate eld termination Reapetable and stable level of performance Description Application LANmark-6A Pre-Term Category 6A U/FTP solid LSZH orange screened Jack Category 6A assemblies have been designed specically to support the higher frequencies required for 10 Gigabit Ethernet, while maintain to be fully backwards compatible with today's needs. All LANmark-6A products making the assemblies are screened to ensure immunity from Alien Crosstalk and other external interference and are specied up to frequencies of 500MHz. LANmark-6A EVO jacks use a fully closed rear cover providing 360° screening and excellent coupling attenuation.The Mulipair cable is made of individually screened pairs assembled in several 4 pair units.These LANmark-6A Pre-Term Category 6A assemblies do not requied on-site testing for Alien Crosstalk since this new 10G parameter is met by design. • • • • • • • 10Base-T Ethernet 100Base-TX Fast Ethernet 1000Base-TX Gigabit Ethernet 10GBase-T 10 Gigabit Ethernet IEEE 802.3an 155 Mbit ATM 1.2 Gbit ATM future Cat 6A and Class EA applications Standards International EN 50173-5; IEEE 802.3an; ISO/IEC 11801:2002/ A2:2008; ISO/IEC 24764 National TIA/EIA-568-B.2-10; TIA/ EIA-942 Performance With guaranteed performance to 500MHz, Nexans LANmark-6A Pre-Term Category 6A assemblies provide guaranteed headroom and bandwidth over and above the Category 6A / Class EA requirements of international, european and american standards especially for NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss. When used in combination with LANmark-6A patch cords, the system supports the 10GBase-T applications as dened in IEEE 802.3an, and the full 100m four-connector links and channels meet Category 6A and Class EA requirements as dened in TIA/EIA568B.2 Addendum 10 and ISO/IEC11801 2002/A1:2008. This enables to achieve high performing 4 connectors channels as well as very short link and channel congurations needed in data centres with up to 3 connection points within 12 meters. Installation Nexans LANmark-6A Pre-Term Category 6A assemblies have the advantage of offering signicantly smaller dimensions and reduced weight compared to the equivalent standard 4 pair cables. They also provide a signicant installation advantage. Cable pulling is reduced to one unit. Connectors termination is simply eliminated. All structural hardware items designed for the EVO Snap-In range can be used in all positions of a 4 connector twisted pair cabling channel (PP, CC, CP, TO). 03/12/10 - http://www.nexans.co.uk Page 137 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack • • • • • • • • Fast and straight forward installation No need for on-site termination 360° EMC protection and alien crosstalk compliance Support the 4 connectors channel conguration Support short links Designed for datacentres Numbering on each leg (customizable) Factory tests in paper or electronic format on request Guarantees Nexans LANmark-6A Pre-Term Category 6A assemblies are covered by a parts and labour warranty as described in the Nexans Certied System Warranty. When installed in combination with LANmark-6A patch cords, a 25 year channel warranty can be obtained covering full 10GBase-T support and full Cat 6A/Class EA compliance. 03/12/10 - http://www.nexans.co.uk Page 138 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack Product List Nexans ref. N61C.4F21A6XA6X--New N61D.4F21A6XA6X--New N61E.4F21A6XA6X--New Name LANmark-6A Pre-Term Multipair 3x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Multipair 4x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat 6A LANmark-6A Pre-Term Multipair 6x4 pair Cat 6A U/FTP Solid LSZH Orange Screened Jack Cat 6A = Make to order, = Make to stock Electrical Performance LANmark-6A 4 Connector Channel Part 1 "All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance" Freq Attn NEXT PSNEXT ACR-F in dB in dB in dB in dB in MHz Max Typ Std Min Typ Std Min Typ Std Typ 1 <4 4.0 65.0 67.0 85.0 62.0 64.0 74.8 63.3 69.9 4 4.1 4.1 63.0 65.0 72.9 60.5 62.5 65.0 51.2 57.9 10 6.4 6.3 56.6 58.6 65.0 54.0 56.0 58.5 43.3 49.9 16 8.1 8.0 53.2 55.2 60.9 50.6 52.6 55.1 39.2 45.9 20 9.1 9.0 51.6 53.6 59.0 49.0 51.0 53.5 37.2 43.9 31.25 11.4 11.2 48.4 50.4 55.1 45.7 47.7 50.2 33.4 40.0 62.5 16.3 15.9 43.4 45.4 49.1 40.6 42.6 45.1 27.3 34.0 100 20.8 20.2 39.9 41.9 45.0 37.1 39.1 41.6 23.3 29.9 155 26.2 25.4 36.7 38.7 41.2 33.8 35.8 38.3 19.5 26.1 200 30.0 28.9 34.8 36.8 39.0 31.9 33.9 36.4 17.2 23.9 250 33.8 32.5 33.1 35.1 37.0 30.2 32.2 34.7 15.3 22.0 300 37.3 35.7 31.7 33.7 35.4 28.8 30.8 33.3 13.7 20.4 500 49.3 46.7 27.9 29.9 31.0 24.8 26.8 24.9 9.3 16.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA 03/12/10 - http://www.nexans.co.uk Page 139 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-6A Pre-Term Multipair Cat 6A RJ45 Jack-Jack Electrical Performance LANmark-6A 4 Connector Channel Part 2 All values are based on Worst Case 4 Connector Channel congurations according ISO11801:2008 AM1 Minimal and maximum values represent guaranteed channel performance PS ACR-F Freq PS ANEXT in dB PS AACR-F in dB RL in dB in dB in MHz Std Typ Std Min Typ Std Min Typ Std Min Typ 1 60.3 66.9 80.0 90.0 92.0 77.0 92.0 94.0 19.0 21.0 21.0 4 48.2 54.9 74.0 89.0 91.0 65.0 80.0 82.0 19.0 21.0 32.0 10 40.3 46.9 70.0 85.0 87.0 57.0 72.0 74.0 19.0 21.0 28.0 16 36.2 42.9 68.0 83.0 85.0 52.9 67.9 69.9 18.0 20.0 26.0 20 34.2 40.9 67.0 82.0 84.0 51.0 66.0 68.0 17.5 19.5 25.0 31.25 30.4 37.0 65.1 80.1 82.1 47.1 62.1 64.1 16.5 18.5 23.1 62.5 24.3 31.0 62.0 77.0 79.0 41.1 56.1 58.1 14.0 16.0 20.0 100 20.3 26.9 60.0 75.0 77.0 37.0 52.0 54.0 12.0 14.0 18.0 155 16.5 23.1 57.1 72.1 74.1 33.2 48.2 50.2 10.1 12.1 16.1 200 14.2 20.9 55.5 70.5 72.5 31.0 46.0 48.0 9.0 11.0 15.0 250 12.3 19.0 54.0 69.0 71.0 29.0 44.0 46.0 8.0 10.0 14.0 300 10.7 17.4 52.8 67.8 69.8 27.5 42.5 44.5 8.0 10.0 13.2 500 6.3 13.0 49.5 64.5 66.5 23.0 38.0 40.0 8.0 10.0 11.0 *Standard values based on ISO11801:2002/A1:2008 ClassEA Selling delivery information Nexans LANmark-6A Pre-Term Category 6A assemblies can be ordered in any length up to 90m. Please refer to Nexans Design Guidelines for length calculations and limitations according to the standards. Individual packaking in boxes (L <30m) or one way reel (L>30m). Customized packaking on demand. 03/12/10 - http://www.nexans.co.uk Page 140 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Optical Fibre A full spectrum of Nexans LANmark ber solutions is available for various performance levels and constructions to meet different applications and environmental conditions. LANmark bre solutions approach offers exibility and scalability for campus and building backbones, horizontal cabling applications, device termination in data centers and storage area networks. Nexans bre solutions are a fully integrated element of our LAN systems and covered within the system warranty. The range includes: • • • • Cables Connectivity Hardware Pre-Terminated Fibre Assemblies 03/12/10 - http://www.nexans.co.uk Page 141 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre Cables A wide variety of cable designs and bre grade are available, meeting the needs of each mission critical applications. Designed for high performance and scalability for LAN, SAN and Campus applications, LANmark-OF technology deliver premium performance and reliability. A large number of constructions are available: Tight / loose construction, PE / LSZH., rodent resistant / dielectric, … • • • • • • UT UC UD TB TBW+ ZC In addition, Nexans proposes the best cost effective solution. 7 different bre grades are available to best address the level of performance required.p> LANmark-OF 1, OF 2 & OF sm Standard Multimode & Singlemode performance. LANmark-OF 1 is the MM62.5 version, LANmark-OF 2 the MM50 version, LANmark-OF sm the singlemode version. LANmark-OF 1xt & OF 2xt Laser optimised, enhanced OM1 & OM2 respectively (50/125 & 62.5/125) bre cables designed to provide extended distances for Gigabit applications. LANmark-OF 3 & OF 3xt OM3 compliant 50/125 for 10 Gigabit applications up to 300m and up to 450m respectively.. EIA Fibre Colour Table EIA Fibre Colour Coding Fibre Colour Fibre Colour 1 Blue 13 Blue + 1 ring I 2 Orange 14 Orange + 1 ring I 3 Green 15 Green + 1 ring I 4 Brown 16 Brown + 1 ring I 5 Grey 17 Grey + 1 ring I 6 White 18 White + 1 ring I 7 Red 19 Blue + 2 rings II 8 Black 20 Orange + 2 rings II 9 Yellow 21 Green + 2 rings II 10 Violet 22 Brown + 2 rings II 11 Pink 23 Grey + 2 rings II 12 Turquoise 24 White + 2 rings II 03/12/10 - http://www.nexans.co.uk Page 142 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Optical cable specifications • Full range of standard compliant multimode cables • Singlemode OS2 cables Description LANmark-OF OM3 and OM4: Fibre cables with high performance multimode fibres for 10, 40 and 100 Gb/s Ethernet LAN applications LANmark-OF OM3 and OM4 from Nexans Cabling Solutions offers fully OM3 and OM4 standard compliant multimode bres. LANmark-OF OM3 and OM4 ensures highest bandwidth performance for Premises, Local Area Network (LAN) and Storage Area Network (SAN) while its optimised design for low-cost 850 nm lasers (VCSEL) contributes to overall system cost reduction. The low attenuation values of 3.0 dB/km @ 850 nm exceed the requirements of the ISO/IEC 11801 standard. The superior geometric tolerances compared to the bre standard reduce the connector loss due to improved coupling from the light. The effective modal bandwidth is measured with the most stringent DMD characterisation methods: LANmark-OF cables are measured against both the Effective Model Bandwidth Calculated (EMBc) method and the mask templates standard. LANmark-OF OM3: Key performance characteristics • Guarantees reliable system performance for 10 Gb/s Ethernet serial transmission over 330 m. • Guarantees reliable system performance for 40 Gb/s and 100 Gb/s Ethernet transmission over 100 m. • Guaranteed OM3 compliance: Effective Modal Bandwidth (EMB) of 2000 Mhz.km, Overlled Launch Bandwidth (OFL) of 1500 Mhz.km @ 850 nm and 500 Mhz.km @ 1300 nm. • Compliant to IEC 60793-2-10 as bre type A1a.2 Standards International ISO/IEC 11801 LANmark-OF OM4: Key performance characteristics • Guarantees reliable system performance for 10 Gb/s Ethernet serial transmission over 550 m • Guarantees reliable system performance for 40 Gb/s and 100 Gb/s Ethernet transmission over 150 m with LANmark-OF low loss connectivity. • Guaranteed OM4 compliance: Effective Modal Bandwidth (EMB) of 4700 Mhz.km, Overlled Launch Bandwidth (OFL) of 3500 Mhz.km @ 850 nm and 500 Mhz.km @ 1300 nm. • Compliant to IEC 60793-2-10 as bre type A1a.3 Standardization and compliances for LANmark-OF OM3 and LANmark-OF OM4 • IEC 60793-1-49: differential mode delay (DMD) to measure effective modal bandwidth (EMB) • IEC 60793-1-41: overlled mode launch bandwidth (OFL BW) • ISO/IEC 11801 (2) as OM3 and OM4 bre • IEC 60793-2-10 as bre type A1a.2 for LANmark-OF OM3 • IEC 60793-2-10 as bre type A1a.3 for LAnmark-OF OM4 LANmark-OF OS2 Singlemode cables with low water peak singlemode fibre (G.652.D) 03/12/10 - http://www.nexans.co.uk Page 143 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Optical cable specifications Singlemode OS2 cables from Nexans Cabling Solution are cables with full spectrum bres and provide enhanced performance across the entire 1260 nm to 1625 nm wavelength range. Due to its long-term low attenuation at the 1383 nm water peak region the bres allow operation in the expanded band (wavelength across 1360 to 1480 nm). Its full-spectrum capability allows use of lasers for DWDM and CWDM technologies. LANmark-OF OS2 Singlemode cables have low attenuation values across the entire wavelength range. They are full compatibility and interoperability with the installed bre base, including standard singlemode bre according to ITU-T G652A, B and C. Standardization Singlemode OS2 • • • • and compliances for LANmark-OF ITU-T as bre type G.652.D Singlemode OS2 cable dened in ISO/IEC 11801 amendment 2 IEC 60793-1 IEC 60793-2-50 as bre type B1.3 LANmark-OF OM3 and OM4: Optical Performance Characteristics OM3 Spec Values OM4 Spec Values Unit Bandwidth (Overlled Launch) 850 nm ≥ 1500 ≥ 3500 Mhz.km Bandwidth (Overlled Launch) 1300 nm ≥ 500 ≥ 500 Mhz.km Effective Modal Bandwidth (EMB) 850 nm ≥ 2000 ≥ 4700 Mhz.km Transmission link lengths for 1 Gb/s (SX/LX) 880/550 900/550 m Transmission link lengths for 10 Gb/s (SR/LX4) 330/300 550*/300 m Transmission link lengths for 40 Gb/s (SR4) 100 150* m Transmission link lengths for 100 Gb/s (SR10) 100 150* m Attenuation 850 nm 3.0 3.0 dB/km Attenuation 1300 nm 1.0 1.0 dB/km Attenuation uniformity ≤ 0.2 ≤ 0.2 dB 0.20 ± 0.02 0.20 ± 0.02 Numerical Aperture * with engineered link of maximum 1.0 dB connector insertion loss LANmark-OF OM3 and OM4: Geometrical Characteristics Characteristic Core Diameter Core Non-Circularity Core/Clad Concentricity Cladding Diameter Cladding Non-Circularity Coating Diameter Coating/Clad Concentricity Error Spec Values Unit 50 ± 2.5 µm ≤ 6.0 % ≤ 1.5 µm 125 ± 1.0 µm ≤ 1.0 % 250 ± 15.0 µm ≤ 10.0 µm 03/12/10 - http://www.nexans.co.uk Page 144 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Optical cable specifications LANmark-OF OS2 Singlemode cables: Optical Performance Characteristics Spec Values Fibre type Unit G.652.D Transmission link length for 1000Base-LX 5000 m Transmission link length for 10GBase-LR 10000 m Transmission link length for 10GBase-LX4 10000 m Transmission link length for 10Gbit-FC 10000 m Attenuation 1300 nm 0.40 dB/km Attenuation 1385 nm 0.40 dB/km Attenuation 1550 nm 0.28 dB/km Attenuation uniformity ≤ 0.2 dB Cut-off wavelength 1150 - 1330 nm ≤ 3.5 ps/nm.km Dispersion 1285-1330 nm Dispersion 1550 nm Zero dispersion Dispersion mode polarisation ≤ 18 ps/nm.km 1310 ± 10 nm ≤ 0.2 ps/√km LANmark-OF Singlemode OS2 cables: Geometrical Characteristics Characteristic Spec Values Unit Mode Field Diameter 9.2 ± 0.5 µm Cladding Diameter 125 ± 1.0 µm Coating Diameter 245 ± 10.0 µm Core Non-Circularity ≤ 6.0 % Cladding Non-Circularity ≤ 2.0 % Proof test 100 psi 03/12/10 - http://www.nexans.co.uk Page 145 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Tight Buffer Indoor • Tight Buffer Indoor optical bre cable • Indoor cable • Aramid yarns for ease of installation • Designed for direct termination and splicing • Up to 24 bres and available in all bre grades Description Description and Application The LANmark-OF Tight buffer Indoor has 900 um buffered bres. This second coating till 900 um provides additional protection of the bres and facilitates the handling when terminating the bres in a patch panel. The easy strip tight buffer design allows stripping the bre over 10 cm in one action. The LANmark-OF Tight buffer Indoor is most suitable for direct termination by either anaerobic or hot melt connectors. The tight buffered bres can also be terminated with splicing of pigtails. The dry structure of the LANmark-Of Tight Buffer Indoor allows both vertical and horizontal installations. It complies with the indoor re requirements. The cables can also be installed in a duct by pulling. Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. Standards Outer sheath in LSZH material Aramid Yarns Optical bre (900 um) Central Strength element (not for 2 bres) International ISO/IEC 11801 Characteristics • • • • • • • • Designed for direct termination and splicing Indoor cable for horizontal and vertical installations Dielectric design Flame retardant (IEC 60332-1) Fire retardant (IEC 60332-3) Aramid yarns for ease of handling and as strength element Available in all bre grades Available till 24 bres Mechanical resistance to impacts 100 impacts of 1 N.m Flame retardant IEC 60332-1 Fire retardant IEC 60332-3 Ambient installation temperature, range 0 .. 40 °C 03/12/10 - http://www.nexans.co.uk Operating temperature, range -20 .. 60 °C Storage temperature, range -40 .. 60 °C Page 146 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Tight Buffer Indoor Characteristics Mechanical characteristics Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Usage characteristics Flame retardant Fire retardant Ambient installation temperature, range Operating temperature, range Storage temperature, range 100 impacts of 1 N.m 100 N/cm IEC 60332-1 IEC 60332-3 0 .. 40 °C -20 .. 60 °C -40 .. 60 °C Mechanical and Dimensional Characteristics for Tight Buffer Indoor Nb optical fibres 2 4 6 8 12 24 Nom. outer diam. [mm] 4.7 4.6 4.6 5.3 6.6 7.3 Approx. weight [kg/km] 17 24 24 33 48 60 static bending rad. [mm] 35 45 45 70 70 75 Min. dynamic operating bending rad. [mm] 100.0 100.0 100.0 110.0 135.0 150.0 Maximum pulling Maximum operating force (IEC 60794-1-2pulling force E1) [N] [N] 800 400 700 200 700 200 1200 300 1200 300 1900 550 N-numbers for Tight Buffer Indoor Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 Nexans ref. N160.TBIN02 N160.TBIN04 N160.TBIN06 N160.TBIN08 N160.TBIN12 N160.TBIN24 N162.TBIN02 N162.TBIN04 N162.TBIN06 N162.TBIN08 N162.TBIN12 N162.TBIN24 N165.TBIN02 N165.TBIN04 N165.TBIN06 N165.TBIN08 N165.TBIN12 N165.TBIN24 N167.TBIN02 N167.TBIN04 N167.TBIN06 N167.TBIN08 N167.TBIN12 N167.TBIN24 Name LANmark-OF Tight Buffer Indoor 2x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 4x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 6x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 8x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 12x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 24x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM2 LSZH Orange LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM3 LSZH Orange LANmark-OF Tight Buffer Indoor 2x Multimode 50/125 OM4 LSZH Orange LANmark-OF Tight Buffer Indoor 4x Multimode 50/125 OM4 LSZH Orange LANmark-OF Tight Buffer Indoor 6x Multimode 50/125 OM4 LSZH Orange LANmark-OF Tight Buffer Indoor 8x Multimode 50/125 OM4 LSZH Orange LANmark-OF Tight Buffer Indoor 12x Multimode 50/125 OM4 LSZH Orange LANmark-OF Tight Buffer Indoor 24x Multimode 50/125 OM4 LSZH Orange 03/12/10 - http://www.nexans.co.uk Page 147 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Tight Buffer Indoor Fiber optic type SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Nexans ref. N164.TBIN02 N164.TBIN04 N164.TBIN06 N164.TBIN08 N164.TBIN12 N164.TBIN24 Name LANmark-OF Tight Buffer Indoor 2x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Tight Buffer Indoor 4x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Tight Buffer Indoor 6x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Tight Buffer Indoor 8x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Tight Buffer Indoor 12x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Tight Buffer Indoor 24x Singlemode 9/125 OS2 LSZH Yellow 03/12/10 - http://www.nexans.co.uk Page 148 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Tight Buffer Universal • Tight Buffer Universal optical bre cable • Indoor cable and outdoor installation in a duct • Fully waterproof and rodent retardant • Designed for direct termination and splicing • Up to 24 bres and available in all bre grades Description Description and Application The LANmark-OF Tight buffer Universal has 900 um buffered bres. This second coating till 900 um provides additional protection of the bres and facilitates the handling when terminating the bres in a patch panel. The easy strip tight buffer design allows stripping the bre over 10 cm in one action. The LANmark-OF Tight buffer Universal is most suitable for direct termination by either anaerobic or hot melt connectors. The tight buffered bres can also be terminated with splicing of pigtails. The dry structure of the LANmark-Of Tight Buffer Universal allows both vertical and horizontal installations. It complies with the indoor re requirements. The cables can also be installed in a duct by pulling. The LANmark-OF Tight Buffer Universal can be used for outdoor installation in a duct: the water tight glass yarns make the cables fully waterproof and rodent resistant. Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. LSZH outer sheath with UV resistant additive Watertight glass yarns Optical bres (900 um) Central strength element Standards International ISO/IEC 11801 Characteristics • • • • • • • • • • Designed for direct termination and splicing Dielectric design Indoor cable for horizontal and vertical installations Flame retardant (IEC 60332-1) and re retardant (IEC 60332-3) Outdoor cable for installation in a duct Fully waterproof Rodent resistant UV resistant Available in all standard compliant bre grades Available till 24 bres Mechanical resistance to impacts 100 impacts of 1 N.m Flame retardant IEC 60332-1 Fire retardant IEC 60332-3 Ambient installation temperature, range 0 .. 40 °C 03/12/10 - http://www.nexans.co.uk Operating temperature, range -40 .. 70 °C Storage temperature, range -40 .. 70 °C Page 149 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Tight Buffer Universal Characteristics Mechanical characteristics Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Usage characteristics Flame retardant Fire retardant Ambient installation temperature, range Operating temperature, range Storage temperature, range 100 impacts of 1 N.m 100 N/cm IEC 60332-1 IEC 60332-3 0 .. 40 °C -40 .. 70 °C -40 .. 70 °C Mechanical and Dimensional Characteristics for Tight Buffer Universal Number of optical fibres Nominal outer diameter Approximate weight Minimum static operating bending radius Minimum dynamic operating bending radius Maximum pulling force (IEC 60794-1-2-E1) Maximum operating pulling force 4 5.7 38 90 120.0 1000 300 6 5.7 38 90 120.0 1000 300 8 6.5 47 100 130.0 1300 400 12 7.5 68 120 150.0 1700 500 24 10.6 135 160 210.0 2300 550 mm kg/km mm mm N N N-numbers for Tight Buffer Universal Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Nexans ref. N160.TBUN04 N160.TBUN06 N160.TBUN08 N160.TBUN12 N160.TBUN24 N162.TBUN04 N162.TBUN06 N162.TBUN08 N162.TBUN12 N162.TBUN24 N165.TBUN04 N165.TBUN06 N165.TBUN08 N165.TBUN12 N165.TBUN24 N167.TBUN04 N167.TBUN06 N167.TBUN08 N167.TBUN12 N167.TBUN24 N164.TBUN04 N164.TBUN06 N164.TBUN08 N164.TBUN12 N164.TBUN24 Name LANmark-OF Tight Buffer Universal 4x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Tight Buffer Universal 6x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Tight Buffer Universal 8x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Tight Buffer Universal 12x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Tight Buffer Universal 24x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM2 LSZH Black LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM2 LSZH Black LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM2 LSZH Black LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM2 LSZH Black LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM2 LSZH Black LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM3 LSZH Black LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM3 LSZH Black LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM3 LSZH Black LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM3 LSZH Black LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM3 LSZH Black LANmark-OF Tight Buffer Universal 4x Multimode 50/125 OM4 LSZH Black LANmark-OF Tight Buffer Universal 6x Multimode 50/125 OM4 LSZH Black LANmark-OF Tight Buffer Universal 8x Multimode 50/125 OM4 LSZH Black LANmark-OF Tight Buffer Universal 12x Multimode 50/125 OM4 LSZH Black LANmark-OF Tight Buffer Universal 24x Multimode 50/125 OM4 LSZH Black LANmark-OF Tight Buffer Universal 4x Singlemode 9/125 OS2 LSZH Black LANmark-OF Tight Buffer Universal 6x Singlemode 9/125 OS2 LSZH Black LANmark-OF Tight Buffer Universal 8x Singlemode 9/125 OS2 LSZH Black LANmark-OF Tight Buffer Universal 12x Singlemode 9/125 OS2 LSZH Black LANmark-OF Tight Buffer Universal 24x Singlemode 9/125 OS2 LSZH Black 03/12/10 - http://www.nexans.co.uk Page 150 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Indoor • Micro-Bundle Indoor optical bre cable • Indoor cable for backbones and data centres • Small, but mechancial strong cable • Designed for splicing with pigtails • 12-96 bres and available in all bre grades Description Description and Application The new Micro-Bundle technology from Nexans allows to manufacture a exible and small tube. This Micro-Bundle is the central part of the new “LANmark-OF Micro-Bundle Indoor” cable design. The Micro-Bundle contains 12 bres with a bre diameter of 250 um. Termination of these bres is done with splicing with pigtails. Up to 8 Micro-bundles are arranged around a central strength element. Aramid yarns provide additional strength and make the cable installer friendly. The combination of the Micro-Bundle technology, the central strength element and aramid yarns result in a mechanical robust, but also small and exible cable. This makes it a optimised cable for data centres and backbones The small bending radius of the LANmark-OF Micro-Bundle Indoor makes the cable easy to arrange in patch panels, in cable trays and in ducts. The LANmark-OF Micro-Bundle Indoor complies with the indoor re requirements. Since there is no drip effect of the very limited amount of gel the cable is optimised for both horizontal and vertical installations. Standards International ISO/IEC 11801 Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. 5. Central strength element Micro-Bundle with 12 bres Optical bre (250 µm) Reinforced aramid yarns Outer sheath in LSZH material Mechanical resistance to impacts 10 impacts of 1 N.m Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -10 .. 60 °C Storage temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 151 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Indoor Characteristics • • • • • • • • • • • Micro-Bundle design for easy installation Indoor cable for horizontal and vertical installations Data centre cable Flame retardant (IEC 60332-1) Fire retardant (IEC 60332-3) All dielectric design Designed for termination by splicing Aramid yarns for ease of handling and as strength element 12 bres per Micro-Bundle Available in 12, 24, 48 and 96 bres Available in all bre grades Characteristics Mechanical characteristics Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Maximum pulling force (IEC 60794-1-2-E1) Maximum operating pulling force Usage characteristics Ambient installation temperature, range Operating temperature, range Storage temperature, range Fire retardant Flame retardant 10 impacts of 1 N.m 100 N/cm 1000 N 250 N 0 .. 40 °C -10 .. 60 °C -20 .. 60 °C IEC 60332-3 IEC 60332-1 Mechanical and Dimensional Characteristics for Micro-Bundle Indoor Nb optical fibres 12 24 48 96 Nom. outer diam. [mm] 5.4 5.4 5.4 6.4 Approx. weight [kg/km] 37 37 37 50 static bending rad. [mm] 65 65 65 65 Min. dynamic operating bending rad. [mm] 80.0 80.0 80.0 100.0 N-numbers for Micro-Bundle Indoor Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 Mechanical resistance to impacts 10 impacts of 1 N.m Nexans ref. N160.MBIN12 N160.MBIN24 N160.MBIN48 N160.MBIN96 N162.MBIN12 Name LANmark-OF Micro-Bundle Indoor 12x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Micro-Bundle Indoor 24x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Micro-Bundle Indoor 48x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Micro-Bundle Indoor 96x Multimode 62,5/125 OM1 LSZH Orange LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM2 LSZH Orange Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -10 .. 60 °C Storage temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 152 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Indoor Fiber optic type OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Mechanical resistance to impacts 10 impacts of 1 N.m Nexans ref. N162.MBIN24 N162.MBIN48 N162.MBIN96 N165.MBIN12 N165.MBIN24 N165.MBIN48 N165.MBIN96 N167.MBIN12 N167.MBIN24 N167.MBIN48 N167.MBIN96 N164.MBIN12 N164.MBIN24 N164.MBIN48 N164.MBIN96 Name LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM2 LSZH Orange LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM2 LSZH Orange LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM2 LSZH Orange LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM3 LSZH Orange LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM3 LSZH Orange LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM3 LSZH Orange LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM3 LSZH Orange LANmark-OF Micro-Bundle Indoor 12x Multimode 50/125 OM4 LSZH Orange LANmark-OF Micro-Bundle Indoor 24x Multimode 50/125 OM4 LSZH Orange LANmark-OF Micro-Bundle Indoor 48x Multimode 50/125 OM4 LSZH Orange LANmark-OF Micro-Bundle Indoor 96x Multimode 50/125 OM4 LSZH Orange LANmark-OF Micro-Bundle Indoor 12x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Micro-Bundle Indoor 24x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Micro-Bundle Indoor 48x Singlemode 9/125 OS2 LSZH Yellow LANmark-OF Micro-Bundle Indoor 96x Singlemode 9/125 OS2 LSZH Yellow Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -10 .. 60 °C Storage temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 153 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Universal (24F-72F) • Micro-Bundle Universal optical bre cable • Indoor cable and outdoor installation in a duct • Fully waterproof and rodent resistant • Small, but mechancial strong cable • Designed for splicing with pigtails • 24-72 bres and available in all bre grades Description Description and Application The new Micro-Bundle technology from Nexans allows to manufacture a exible and small tube. This Micro-Bundle is the central part of the new “LANmark-OF Micro-Bundle Universal” cable design. Each Micro-Bundle contains 12 bres with a bre diameter of 250 um. Termination of these bres is done with splicing with pigtails. Up to 6 Micro-Bundles are arranged around a central strength element. The combination of the Micro-Bundle technology, the central strength element and the glass yarns result in a mechanical robust, but also in a small and exible cable. The small bending radius of the LANmark-OF Micro-Bundle Universal makes the cable easy to arrange in patch panels, in cable trays and in ducts. The watertight glass yarns and the very limited amount of gel inside the tube make the LANmark-OF Micro-Bundle Universal design watertight, rodent resistant and suitable for installation outdoor in a duct by pulling. Standards International ISO/IEC 11801 The LANmark-OF Micro-Bundle Universal complies with the indoor re requirements. Since there is no drip effect of the very limited amount of gel the cable is optimised for both horizontal and vertical installations. Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. 5. Central strength element Optical bre (250 µm) Micro-Bundle with 12 bres Reinforced watertight glass yarns Outer sheath in LSZH material with UV resistant additive Mechanical resistance to impacts 10 impacts of 1 N.m Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -30 .. 60 °C Storage temperature, range -30 .. 60 °C Minimum static operating bending radius 75 mm 03/12/10 - http://www.nexans.co.uk Minimum dynamic operating bending radius 150.0 mm Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 154 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Universal (24F-72F) Characteristics • • • • • • • • • • • Micro-Bundle design for easy installation Indoor cable for horizontal and vertical installations Flame retardant (IEC 60332-1) Fire retardant (IEC 60332-3) Outdoor cable for installation in a duct Waterproof structure, rodent resistant and UV-resistant All dielectric design Designed for termination by splicing 12 bres per Micro-Bundle Available in 24, 48 and 96 bres Available in all bre grades Characteristics Dimensional characteristics Approximate weight Nominal outer diameter Mechanical characteristics Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Maximum operating pulling force Maximum pulling force (IEC 60794-1-2-E1) Usage characteristics Ambient installation temperature, range Operating temperature, range Storage temperature, range Minimum static operating bending radius Minimum dynamic operating bending radius Fire retardant Flame retardant 64 kg/km 7.2 mm 10 impacts of 1 N.m 100 N/cm 600 N 2000 N 0 .. 40 °C -30 .. 60 °C -30 .. 60 °C 75 mm 150.0 mm IEC 60332-3 IEC 60332-1 N-number for Micro-Bundle Universal (24F-72F) Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 Mechanical resistance to impacts 10 impacts of 1 N.m Nexans ref. N160.MBUN24 N160.MBUN48 N160.MBUN72 N162.MBUN24 N162.MBUN48 N162.MBUN72 N165.MBUN24 Ambient installation temperature, range 0 .. 40 °C Name LANmark-OF Micro-Bundle Universal 24x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 48x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 72x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM3 LSZH Black Operating temperature, range -30 .. 60 °C Storage temperature, range -30 .. 60 °C Minimum static operating bending radius 75 mm 03/12/10 - http://www.nexans.co.uk Minimum dynamic operating bending radius 150.0 mm Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 155 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Universal (24F-72F) Fiber optic type OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) Mechanical resistance to impacts 10 impacts of 1 N.m Nexans ref. N165.MBUN48 N165.MBUN72 N167.MBUN24 N167.MBUN48 N167.MBUN72 N164.MBUN24 N164.MBUN48 N164.MBUN72 Ambient installation temperature, range 0 .. 40 °C Name LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 24x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 48x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 72x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 24x Singlemode 9/125 OS2 LSZH Black LANmark-OF Micro-Bundle Universal 48x Singlemode 9/125 OS2 LSZH Black LANmark-OF Micro-Bundle Universal 72x Singlemode 9/125 OS2 LSZH Black Operating temperature, range -30 .. 60 °C Storage temperature, range -30 .. 60 °C Minimum static operating bending radius 75 mm 03/12/10 - http://www.nexans.co.uk Minimum dynamic operating bending radius 150.0 mm Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 156 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Universal (4F-12F) • Micro-Bundle Universal optical bre cable • Indoor cable and outdoor installation in a duct • Fully waterproof and rodent retardant • Designed for splicing with pigtails • 4-12 bres and available in all bre grades Description Description and Application The new Micro-Bundle technology from Nexans allows to manufacture a very exible and small tube that is the central part of the new “LANmark-OF MicroBundle Universal” cable design. This results in a small, exible, but mechanical robust cable. The central tube contains up till 12 bres with a bre diameter of 250 um. Termination of these bres is done with splicing with pigtails. The small bending radius of the Micro-Bundle makes the cable easy to arrange in patch panels and for installations in data centres and backbones. The watertight glass yarns and the very limited amount of gel inside the tube makes this cable design watertight and suitable for installation outdoor in a duct by pulling. The re performance of the LANmark-OF Micro-Bundle Universal allows indoor installation as well. Since there is no drip effect of the very limited amount of gel the cable is optimised for both horizontal and vertical installations. Construction 1. 2. 3. 4. 5. Standards Central Micro-Bundle Gel Reinforced watertight glass yarns Ripcord LSZH outer jacket with UV resistant additive International ISO/IEC 11801 Characteristics • • • • • • • • Indoor cable for horizontal and vertical installation Outdoor cable for installation in a duct Designed for termination by splicing Central Micro-Bundle design for easy installation All dielectric Waterproof structure, Rodent retardant and UV-resistant Flame retardant (IEC 60332-1) and re retardant (IEC 60331-3) Available in all bre grades and from 4-12 bres Mechanical resistance to impacts 1 impact of 3 N.m Flame retardant IEC 60332-1 Fire retardant IEC 60332-3 Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -40 .. 60 °C Minimum static operating bending radius 60 mm Minimum dynamic operating bending radius 60.0 mm Page 157 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Micro-Bundle Universal (4F-12F) Characteristics Dimensional characteristics Approximate weight Nominal outer diameter Mechanical characteristics Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Maximum operating pulling force Maximum pulling force (IEC 60794-1-2-E1) Usage characteristics Flame retardant Fire retardant Ambient installation temperature, range Operating temperature, range Storage temperature, range Minimum static operating bending radius Minimum dynamic operating bending radius 42 kg/km 5.6 mm 1 impact of 3 N.m 200 N/cm 700 N 2200 N IEC 60332-1 IEC 60332-3 0 .. 40 °C -20 .. 60 °C -40 .. 60 °C 60 mm 60.0 mm N-numbers for Micro-Bundle Universal Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Nexans ref. N160.MBUN04 N160.MBUN06 N160.MBUN08 N160.MBUN12 N162.MBUN04 N162.MBUN06 N162.MBUN08 N162.MBUN12 N165.MBUN04 N165.MBUN06 N165.MBUN08 N165.MBUN12 N167.MBUN04 N167.MBUN06 N167.MBUN08 N167.MBUN12 N164.MBUN04 N164.MBUN06 N164.MBUN08 N164.MBUN12 Name LANmark-OF Micro-Bundle Universal 4x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 6x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 8x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 12x Multimode 62,5/125 OM1 LSZH Black LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM2 LSZH Black LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM3 LSZH Black LANmark-OF Micro-Bundle Universal 4x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 6x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 8x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 12x Multimode 50/125 OM4 LSZH Black LANmark-OF Micro-Bundle Universal 4x Singlemode 9/125 OS2 LSZH Black LANmark-OF Micro-Bundle Universal 6x Singlemode 9/125 OS2 LSZH Black LANmark-OF Micro-Bundle Universal 8x Singlemode 9/125 OS2 LSZH Black LANmark-OF Micro-Bundle Universal 12x Singlemode 9/125 OS2 LSZH Black 03/12/10 - http://www.nexans.co.uk Page 158 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UD PE • UD optical bre cables • Suitable for outdoor in ducts or direct burial • Full dielectric armour • Available in all bre grades and till 24 bres • Rodent resistance Description Description and Application The LANmark-OF UD PE cable is designed as a campus cable. It can be pulled in a duct outside or can be direct buried. Its full dielectric armouring does not provide an electrical path and hence the cable can be used to connect 2 buildings. The central loose tube is surrounded by robust strength elements: Fibre Reinforced Plastic (FRP) elements. These FRP provide the cable with a high rodent resistant and a high resistant against impacts and compression. There are 4 x FRP and 5 x llers for bre counts 4-12. For 14-24 bres there are 5 X FRP and 5 X llers. The loose tube design has a capacity of up to 24 bres. Diameter of the bres is 250 um. Termination of these bres is done with splicing of pigtails. The cable is watertight due to the gel in the loose tube and the watertight glass yarns. Standards International ISO/IEC 11801 Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. 5. 6. 7. Optical bres (250 um) Gel Loose tube Fillers Fibre Reinforced Plastic strength elements Reinforced watertight glass yarns PE outer jacket with UV resistant additive Characteristics Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -30 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -40 .. 70 °C Page 159 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UD PE • • • • • • • • Outdoor cable for installation in a duct or direct burial Designed for termination by splicing Central loose tube design All dielectric design with FRP reinforcement and glass yarns Waterproof structure, rodent resistant and UV-resistant Available in all bre grades Available from 4-24 bres Excellent friction properties Characteristics Usage characteristics Ambient installation temperature, range Operating temperature, range Storage temperature, range 0 .. 40 °C -30 .. 60 °C -40 .. 70 °C Mechanical and Dimensional Characteristics for LANmark-OF UD PE Min. dynamic Approx. operating weight bending rad. [kg/km] [mm] static bending rad. [mm] Crush resistance Mechanical (IEC 60794-1- resistance to impacts E3) [N/cm] Nb optical fibres Nom. outer diam. [mm] 4 8.1 50 205.0 160 300 6 8.1 50 205.0 160 300 8 8.1 50 205.0 160 300 12 8.1 50 205.0 160 300 24 9,1 73 225,0 180 400 Maximum pulling force Maximum (IEC operating 60794-1-2- pulling force E1) [N] [N] 100 impacts of 3 N.m 100 impacts of 3 N.m 100 impacts of 3 N.m 100 impacts of 3 N.m 100 impacts of 5 N.m 1150 560 1150 560 1150 560 1150 560 1450 700 N-numbers for LANmark-OF UD PE Nexans ref. N160.681 N160.682 N160.683 N160.685 N160.691 N162.681 N162.682 N162.683 Ambient installation temperature, range 0 .. 40 °C Name LANmark-OF UD 4x Multimode 62,5/125 OM1 PE Black LANmark-OF UD 6x Multimode 62,5/125 OM1 PE Black LANmark-OF UD 8x Multimode 62,5/125 OM1 PE Black LANmark-OF UD 12x Multimode 62,5/125 OM1 PE Black LANmark-OF UD 24x Multimode 62,5/125 OM1 PE Black LANmark-OF UD 4x Multimode 50/125 OM2 PE Black LANmark-OF UD 6x Multimode 50/125 OM2 PE Black LANmark-OF UD 8x Multimode 50/125 OM2 PE Black Operating temperature, range -30 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -40 .. 70 °C Page 160 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UD PE Nexans ref. N162.685 N162.691 N164.681 N164.682 N164.683 N164.685 N164.691 N165.681 N165.682 N165.683 N165.685 N165.691 N167.681 N167.682 N167.683 N167.685 N167.691 Ambient installation temperature, range 0 .. 40 °C Name LANmark-OF UD 12x Multimode 50/125 OM2 PE Black LANmark-OF UD 24x Multimode 50/125 OM2 PE Black LANmark-OF UD 4x Singlemode 9/125 OS2 PE Black LANmark-OF UD 6x Singlemode 9/125 OS2 PE Black LANmark-OF UD 8x Singlemode 9/125 OS2 PE Black LANmark-OF UD 12x Singlemode 9/125 OS2 PE Black LANmark-OF UD 24x Singlemode 9/125 OS2 PE Black LANmark-OF UD 4x Multimode 50/125 OM3 PE Black LANmark-OF UD 6x Multimode 50/125 OM3 PE Black LANmark-OF UD 8x Multimode 50/125 OM3 PE Black LANmark-OF UD 12x Multimode 50/125 OM3 PE Black LANmark-OF UD 24x Multimode 50/125 OM3 PE Black LANmark-OF UD 4x Multimode 50/125 OM4 PE Black LANmark-OF UD 6x Multimode 50/125 OM4 PE Black LANmark-OF UD 8x Multimode 50/125 OM4 PE Black LANmark-OF UD 12x Multimode 50/125 OM4 PE Black LANmark-OF UD 24x Multimode 50/125 OM4 PE Black Operating temperature, range -30 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -40 .. 70 °C Page 161 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UC PE UC optical bre cables • • • • Outdoor in ducts or direct burial Corrugated steel tape armour Available in all bres grades Provides full rodent protection Description Description and Application The construction is suitable for use outdoor in ducts and for direct burial. It consists of a corrugated steel tape armouring providing full rodent protection. It is surrounded by glass yarns. The cable has a HDPE outer jacket. The loose tube design has a capacity of up to 24 bres. Diameter of the bres is 250 um. Termination of these bres is done with splicing of pigtails. The cable is watertight due to the gel in the loose tube and the watertight glass yarns. Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. 5. 6. Optical bres (250 um) Gel Loose tube Reinforced watertight glass yarns Corrugated steel tape armour PE outer jacket with UV resistant additive Standards International ISO/IEC 11801 Characteristics • • • • • • • Outdoor cable for installation in a duct or direct burial Designed for termination by splicing Central loose tube design Corrugated steel protection Waterproof structure, rodent resistant and UV-resistant Available in all bre grades Available from 4-24 bres Mechanical resistance to impacts 100 impacts of 3 N.m Minimum dynamic operating bending radius 200.0 mm Minimum static operating bending radius 140 mm Operating temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -30 .. 60 °C Ambient installation temperature, range 0 .. 40 °C Page 162 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UC PE Characteristics Dimensional characteristics Nominal outer diameter Approximate weight Mechanical characteristics Mechanical resistance to impacts Maximum pulling force (IEC 60794-1-2-E1) Maximum operating pulling force Crush resistance (IEC 60794-1-E3) Usage characteristics Minimum dynamic operating bending radius Minimum static operating bending radius Operating temperature, range Storage temperature, range Ambient installation temperature, range 9.5 mm 100 kg/km 100 impacts of 3 N.m 1500 N 450 N 300 N/cm 200.0 mm 140 mm -20 .. 60 °C -30 .. 60 °C 0 .. 40 °C N-numbers for LANmark-OF UC PE Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Nexans ref. N160.181 N160.182 N160.183 N160.185 N160.191 N162.181 N162.182 N162.183 N162.185 N162.191 N165.181 N165.182 N165.183 N165.185 N165.191 N167.181 N167.182 N167.183 N167.185 N167.191 N164.181 N164.182 N164.183 N164.185 N164.191 Name LANmark-OF UC 4x Multimode 62,5/125 OM1 PE Black LANmark-OF UC 6x Multimode 62,5/125 OM1 PE Black LANmark-OF UC 8x Multimode 62,5/125 OM1 PE Black LANmark-OF UC 12x Multimode 62,5/125 OM1 PE Black LANmark-OF UC 24x Multimode 62,5/125 OM1 PE Black LANmark-OF UC 4x Multimode 50/125 OM2 PE Black LANmark-OF UC 6x Multimode 50/125 OM2 PE Black LANmark-OF UC 8x Multimode 50/125 OM2 PE Black LANmark-OF UC 12x Multimode 50/125 OM2 PE Black LANmark-OF UC 24x Multimode 50/125 OM2 PE Black LANmark-OF UC 4x Multimode 50/125 OM3 PE Black LANmark-OF UC 6x Multimode 50/125 OM3 PE Black LANmark-OF UC 8x Multimode 50/125 OM3 PE Black LANmark-OF UC 12x Multimode 50/125 OM3 PE Black LANmark-OF UC 24x Multimode 50/125 OM3 PE Black LANmark-OF UC 4x Multimode 50/125 OM4 PE Black LANmark-OF UC 6x Multimode 50/125 OM4 PE Black LANmark-OF UC 8x Multimode 50/125 OM4 PE Black LANmark-OF UC 12x Multimode 50/125 OM4 PE Black LANmark-OF UC 24x Multimode 50/125 OM4 PE Black LANmark-OF UC 4x Singlemode 9/125 OS2 PE Black LANmark-OF UC 6x Singlemode 9/125 OS2 PE Black LANmark-OF UC 8x Singlemode 9/125 OS2 PE Black LANmark-OF UC 12x Singlemode 9/125 OS2 PE Black LANmark-OF UC 24x Singlemode 9/125 OS2 PE Black 03/12/10 - http://www.nexans.co.uk Page 163 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UC LSZH UC optical bre cables • • • • • • Indoor/Outdoor cable Corrugated steel tape armour Gel lled tube All bre grades Provides full rodent protection Low Smoke Zero Halogene (LSZH) Description Description and Application The construction is suitable for indoor/outdoor use. It consists of a corrugated steel tape armouring providing full rodent protection. It is surrounded by glass yarns. The cable has a LSZH outer jacket. The loose tube design has a capacity of up to 24 bres. Diameter of the bres is 250 um. Termination of these bres is done with splicing of pigtails. The cable is watertight due to the gel in the loose tube and the watertight glass yarns. Construction Legend accompanying the cross section drawing: 1. 2. 3. 4. 5. 6. Optical bres (250 um) Gel Loose tube Reinforced watertight glass yarns Corrugated steel tape armour LSZH outer jacket with UV resistant additive Standards International ISO/IEC 11801 Characteristics • • • • • • • • Indoor/Outdoor cable Flame and re non propagation Designed for termination by splicing Central loose tube design Corrugated steel protection Waterproof structure, rodent resistant and UV-resistant Available in all bre grades Available from 4-24 bres Mechanical resistance to impacts 100 impacts of 3 N.m Minimum dynamic operating bending radius 210.0 mm Minimum static operating bending radius 150 mm Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -30 .. 60 °C Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 164 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF UC LSZH Characteristics Dimensional characteristics Approximate weight Nominal outer diameter Mechanical characteristics Maximum pulling force (IEC 60794-1-2-E1) Maximum operating pulling force Mechanical resistance to impacts Crush resistance (IEC 60794-1-E3) Usage characteristics Minimum dynamic operating bending radius Minimum static operating bending radius Ambient installation temperature, range Operating temperature, range Storage temperature, range Fire retardant Flame retardant 129 kg/km 9.5 mm 1500 N 450 N 100 impacts of 3 N.m 300 N/cm 210.0 mm 150 mm 0 .. 40 °C -20 .. 60 °C -30 .. 60 °C IEC 60332-3 IEC 60332-1 N-numbers for LANmark-OF UC LSZH Fiber optic type OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM1 62.5/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM2 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM3 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 OM4 50/125 SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) SM (G.652D) Nexans ref. N160.471 N160.472 N160.473 N160.475 N160.481 N162.471 N162.472 N162.473 N162.475 N162.481 N165.471 N165.472 N165.473 N165.475 N165.481 N167.471 N167.472 N167.473 N167.475 N167.481 N164.471 N164.472 N164.473 N164.475 N164.481 Name LANmark-OF UC 4x Multimode 62,5/125 OM1 LSZH Black LANmark-OF UC 6x Multimode 62,5/125 OM1 LSZH Black LANmark-OF UC 8x Multimode 62,5/125 OM1 LSZH Black LANmark-OF UC 12x Multimode 62,5/125 OM1 LSZH Black LANmark-OF UC 24x Multimode 62,5/125 OM1 LSZH Black LANmark-OF UC 4x Multimode 50/125 OM2 LSZH Black LANmark-OF UC 6x Multimode 50/125 OM2 LSZH Black LANmark-OF UC 8x Multimode 50/125 OM2 LSZH Black LANmark-OF UC 12x Multimode 50/125 OM2 LSZH Black LANmark-OF UC 24x Multimode 50/125 OM2 LSZH Black LANmark-OF UC 4x Multimode 50/125 OM3 LSZH Black LANmark-OF UC 6x Multimode 50/125 OM3 LSZH Black LANmark-OF UC 8x Multimode 50/125 OM3 LSZH Black LANmark-OF UC 12x Multimode 50/125 OM3 LSZH Black LANmark-OF UC 24x Multimode 50/125 OM3 LSZH Black LANmark-OF UC 4x Multimode 50/125 OM4 LSZH Black LANmark-OF UC 6x Multimode 50/125 OM4 LSZH Black LANmark-OF UC 8x Multimode 50/125 OM4 LSZH Black LANmark-OF UC 12x Multimode 50/125 OM4 LSZH Black LANmark-OF UC 24x Multimode 50/125 OM4 LSZH Black LANmark-OF UC 4x Singlemode 9/125 OS2 LSZH Black LANmark-OF UC 6x Singlemode 9/125 OS2 LSZH Black LANmark-OF UC 8x Singlemode 9/125 OS2 LSZH Black LANmark-OF UC 12x Singlemode 9/125 OS2 LSZH Black LANmark-OF UC 24x Singlemode 9/125 OS2 LSZH Black 03/12/10 - http://www.nexans.co.uk Page 165 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cables - LANmark-OF ZC LSZH ZipCord optical bre cables • • • • Designed for direct termination on ST, SC or LC connectors Suitable for indoor use in horizontal cabling and risers Suitable for use in patch assembly Available in all bre grades Description Application LANmark-OF ZC optical bre cables have been designed for applications where a high level of installation, environmental and optical performance is required. The ZipCord range is most suitable for direct termination in patch assembly and in risers and horizontal cabling. The majority of the tight buffered cables are suitable for both internal & external environments and are all dielectric with excellent ame retardance Applications support : • • • • • • • • FDDI 100 Mbps Ethernet 10 base FL Fast Ethernet 100 base FX Gbit Ethernet 1000 base SX/LX 10Gbit Ethernet 10000 base SX(*) Fibre Channel 1.0625 Gbps ATM 155 Mbps ATM 622 Mbps (*) in accordance with IEEE 802.3ae Standards International ISO/IEC 11801 Performance LANmark-OF Tight Buffered optical bre cables are available with standard multimode & singlemode bres whilst the LANmark-OFxt ranges are supplied with Laser Optimised multimode bres offering extended application distances for Gigabit Ethernet. Construction Legend accompanying the cross section drawing: 1. 2. 3. 900 µm tight buffered bre Aramid yarns reinforcement Flame retardant halogen free outer sheath Flame retardant IEC 60332 Part 3 Cat. C Ambient installation temperature, range 0 .. 40 °C Operating temperature, range -10 .. 70 °C 03/12/10 - http://www.nexans.co.uk Storage temperature, range -30 .. 70 °C Page 166 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cables - LANmark-OF ZC LSZH Characteristics Construction characteristics Type of cable Armour type Material of ller / inner sheath Outer sheath Dimensional characteristics Number of optical bres Height Width Approximate weight Mechanical characteristics Crush resistance (IEC 60794-1-E3) Usage characteristics Installation type Flame retardant Ambient installation temperature, range Operating temperature, range Storage temperature, range Product List Nexans ref. N162.001 N163.001 N165.001 N166.001 N160.001 N161.001 N164.001 Zip Cord (ZC) Unarmoured Aramid yarn LSZH-FR 2 2.8 mm 5.8 mm 14 kg/km 300 N/cm Indoor IEC 60332 Part 3 Cat. C 0 .. 40 °C -10 .. 70 °C -30 .. 70 °C =Make to order, =Make to stock Name Fiber optic type LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM2 LSZH Orange OM2 50/125 LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM2xt LSZH Orange OM2 50/125 Extended Distance LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM3 LSZH Orange OM3 50/125 LANmark-OF ZC (2,8mm) 2x Multimode 50/125 OM3xt LSZH Orange OM3 50/125 Extended Distance LANmark-OF ZC (2,8mm) 2x Multimode 62,5/125 OM1 LSZH Orange OM1 62.5/125 LANmark-OF ZC (2,8mm) 2x Multimode 62,5/125 OM1xt LSZH Orange OM1 62.5/125 Extended Distance LANmark-OF ZC (2,8mm) 2x Singlemode 9/125 OS2 LSZH Yellow SM (G.652D) = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 167 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre Connectors & Connector Accessories LANmark-OF offers cutting edge connectivity products including connectors, couplers, pigtails, patch cords,… Each product has been thoroughly developed to ensure best system offering while meeting stringent international standards. Small Form Factor products Full range of pigtails, patchcords and adaptors supporting both small form factor MT-RJ and LC connectors as well as ST and SC connectors. Snap-in concept Nexans ‘snap-in’ format allows quick and easy installation without screws. They are available in SC format as well as the small form factor LC and MT-RJ connectors. 03/12/10 - http://www.nexans.co.uk Page 168 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Connectors • Connector for on-site termination • Installed using the Nexans anaerobic toolkit • Suitable for installation on 900µm bre as well as on cable Description Nexans offers a large range of Fibre Optics connectors for eld termination practices. All these connectors meet most recent standard ISO 11801 releases. Connector type available : • SC • ST • LC For optimal installations, Nexans recommends to use its Anaerobic Toolkit (ref.: 102.220). This toolkit provides a comprehensive set of tools and consumables for easier on-site jobs and is supplied with illustrated installation manual. Standards International ISO/IEC 11801 Product List Nexans ref. N102.461 N102.462 N205.120 N205.121 N890.008 N205.630 N205.631 Name LANmark-OF ST Connector Anaerobic Multimode for 900µm /2.8mm LANmark-OF Simplex SC Connector Multimode for 900µm / 2.8mm (3M Hot Melt) LANmark-OF Simplex SC Connector Anaerobic Multimode for 900µm /2.8mm LANmark-OF Simplex ST Connector Multimode for 900µm / 2.8mm (3M Hot Melt) LANmark-OF Simplex SC Connector Singlemode for 900µm / 2.8mm (3M Hot Melt) LANmark-OF Simplex LC Connector Anaerobic Multimode for 900µm LANmark-OF Simplex LC Connector Anaerobic Multimode for 1.6-2.2mm =Make to order, =Make to stock Fiber optic type Connector type Multimode ST Multimode SC Multimode SC Multimode ST SingleMode 9/125 Multimode Multimode = Make to order, 03/12/10 - http://www.nexans.co.uk SC LC LC = Make to stock Page 169 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Connector Accessories Description Tools & accessories for termination of Nexans connectors Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 170 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Connector Accessories Product List Nexans ref. N102.221 N102.214 N102.220 N102.222 N102.224 N102.223 N102.225 N102.226 =Make to order, =Make to stock Name Adhesive & Activator for Anaerobic Connector LANmark-OF Toolkit for Anaerobic Connector (extension to hotmelt kit ) LANmark-OF Toolkit for Anaerobic Connector (starter kit) Polishing Paper 1 micron for Anaerobic Toolkit (50/bag) Polishing Paper 12 micron for Anaerobic Toolkit (10/bag) Polishing Paper 3 micron for Anaerobic Toolkit (50/bag) Syringes for Anaerobic Toolkit (50/box) Wipes for Anaerobic Toolkit (100/box) = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 171 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Pre-Terminated Fibre Assemblies This added-value offer enables fast network deployment and removes the requirement for specialized termination training, consumables and toolkits. Every assembly is developed and manufactured by optical engineers to individual customer requirements: cable length, connector type, bre grade, fanouts size, … All LANmark-OF Pre-Term assemblies are fully terminated and tested in a quality assured factory environment. They are delivered with test results and benet from the 25 year LANmark-OF warranty program. LANmark-OF Pre-Term signicantly reduces installation time and cost while guaranteeing full scalability and long lasting reliability for every situation whether campus, backbone, Local/Storage Area Network or Data Centre. 03/12/10 - http://www.nexans.co.uk Page 172 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly Factory Pre-terminated assemblies which combine ease of installation and outstanding performances. 100% customised for your needs, this product meet the most demanding lead-times. Description The solution consist of universal indoor cable assembled in factory with connectors at each end. Any type of connectors can be used for the assembly: ST, SC, LC, MTRJ, etc. Fibre types available: Single mode 9/125µm (OS2 cables with G652D bres) and laser optimised 50/125µm OM3 or OM4 bres. A pulling eye system is positioned at the end of the cable to protect the terminations while pulling the cable. When the cable has been installed, the pulling eye system is cut off and the terminated bres are fed into a patch panel. Since the assembly is done in factory, all pre-terminated bre optic cables are 100% tested and supplied with test results. Applications Interbuilding and Intrabuilding backbones for Local Area Network (LAN) Premise and Campus applications. Horizontal bre distribution to work area and zone. Equipment distribution area trunk cables for Data centre and Storage Area Network (SAN) applications. Standards International ISO/IEC 11801 Applications support : • • • • • Ethernet 10 base FL Fast Ethernet 100 base FX Gigabit Ethernet 1000 base SX/LX 10 Gigabit Ethernet 10G Base SX/LX 1-2-4-10 Gbps Fibre Channel Fibre types The Pre-Terms are available with singlemode (9/125 um) bre with G652D bres. This results in OS2 cables. For multimode laser optimised bres (50/125 um) are available with OM3 or OM4 performance. Details with the exact optical performance can be found in the specic bre datasheets. Benefits • • • • • • • • • • • • • Short & reliable manufacturing lead-time Fast installation times No specialised termination training required No consumables, termination tool kits No cable preparation necessary No cable or connector scrap No termination errors on site Delivered fully tested, labelled and documented High performing connectors: Max IL 0,40dB* Improved end-to-end attenuation Improved application migration Reduced on-site disruption and installation time Highly cost effective solution *For LC-SC-ST 03/12/10 - http://www.nexans.co.uk Page 173 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly Tailor made solution Nexans LANmark-OF pre-term solutions are 100% tailor made solutions. You specify your cable and connectivity requirements and our optical engineers develop and manufacture your end-to-end pre-terminated cable solution. What needs to be specied: 1. Cable type Singlemode OS2-OM3-OM4 2. Fibre count: 6-12-24 3. cable length between enclosures 4. Fanout size (900µ or 2.0 mm) 5. Connector type on each end LC-MTRJ- SC-ST 6. Use of pulling system Consistent quality In order to produce high quality, reliable pre-terminated multi-bre cables, there are a number of physical characteristics that must be addressed. Therefore, all LANmark-OF Pre-term assemblies are fully terminated and tested in a quality assured factory environment. They are delivered with test results protocol and benet from the 25 years LANmark-OF warranty program. 03/12/10 - http://www.nexans.co.uk Page 174 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly LANmark-OF Pre-Term specications Cable Specifications Fibre count Diameter Sheath Min. bending radius 6 12 24 6,10mm 6,60mm 8,1mm LSZH LSZH LSZH 150 mm 150 mm 150 mm Fibre count Max Pulling force Compression Impacts Temp.range 6 12 24 100daN 140daN 140daN 100daN/dm 100daN/dm 100daN/dm 100 impacts of 1 N.m 100 impacts of 1 N.m 100 impacts of 1 N.m -20°C +60°C -20°C +60°C -20°C +60°C Stand. Min RL LANmark-OF Pre-Term Measurement Standard Me chanical Performances Min.bending radius IEC-60794-1-E10 Maximum pulling force IEC-60794-1-E1 Compression IEC-60794-1-E3 Impacts IEC-60794-1-E4 Operating temperatures IEC-60794-1-F1 Connector specifications Type Multimode SC/PC LC/PC ST/PC MT-RJ/PC Single Mode SC/PC LC/PC ST/PC MT-RJ/PC Standard Max IL LANmark-OF Pre-term 0,75 dB 0,75 dB 0,75 dB 0,75 dB 0.35 dB 0.35 dB 0.35 dB 0.35 dB 20dB 20dB 20dB 20dB 35 dB 35 dB 35 dB 35 dB 0,75 dB 0,75 dB 0,75 dB 0,75 dB 0.35 dB 0.35 dB 0.35 dB 0.35 dB 20dB 20dB 20dB 20dB 50 dB 50 dB 50 dB 35 dB 03/12/10 - http://www.nexans.co.uk Page 175 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF OM3, OM4, Singlemode (OS2) Fibre Assembly N-number codication: N155F.TAACFCFPXXX 4: Singlemode (OS2) with G652D F: Fibre type 5: OM3 bre 7: OM4 bre 06: 6 bres AA: bre count 12: 12 bres 24: 24 bres L: LC C: Connector type C: SC T: ST M: MTRJ F: Fan-out type 9: 900 um fanout 2: 2.0 mm fanout A: one side P: pulling eye Y: both sides N: no pulling eye XXX length in meter 03/12/10 - http://www.nexans.co.uk Page 176 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] MPO System MPO-concept The Nexans’ Plug&Play concept is specially designed for the LAN and data centre environment. It facilitates fast installation of a large number of bre connections, high density, quick changes with limited down time and an easy migration path to future applications. The Plug&Play system consists of 3 subcomponents: the MPO-MPO Pre-Term, the Plug&Play modules and the Plug&Play patch panel. The MPO-MPO Pre-Term provides the connectivity between 2 Plug&Play modules installed in the Plug&Play patch panels in 2 different racks. The MPO connector allows to quickly connecting the 12 bres of the MPO-MPO Pre-Term at the back of each Plug&Play module. Inside the Plug&Play module the bres are spread out towards the SC/LC connectors at the front. Optical performance and polarity method Nexans’ Plug&Play modules and bre assemblies are available in 2 performance grades: LANmark-OF MPO connectivity and the newly introduced LANmark-OF MPO low loss connectivity. With the low loss connectivity insertion loss has been reduced by 40 %. It enables more complex data centre conguarations, extended reach, more head room and a migration path to 40G/100G. The bre assemblies are available as LANmark-OF OM3 and LANmark-OF OM4 for extended reach. The Plug&Play modules have LANmark-OF OM4 performance and are backwards compatible with LANmark-OF OM3. With LANmark-OF OM4 and the low loss solution up to 8 modules can be installed for an operational 10G channel. For 40G/100G a 4 connector channel up to 120 m can be supported. Polarity in the optical channel during installation is guaranteed due to a pair ip bre construction. This is in agreement with standard TIA 568-B-1-7-2006 method C. It allows the continuous use of the standard patch cord eliminating the need to buy optically straight and crossed patch cords. Also polarity is maintained with the same type of cassette on both sides of the channel without the need to ip the cassette on one side. Pre-Term assemblies The Pre-Term assemblies are based on the advanced Micro-Bundle technology. A Micro-Bundle is a small and very exible tube with 12 bres and it is the central part of a range of new cable designs. With its small diameter and short bending radius Micro-Bundle cables meet the tight space requirements in data centres. The Micro-Bundle technology has extremely low skew by its advanced manufacturing process and small diameter. The Pre-Term assemblies easily exceed the skew requirements for 40G and 100G Ethernet. With the high bre count of the Pre-Term trunk assemblies the number of installed cables in a data centre can be reduced. The Pre-Terms trunks are available in 12, 24, 48 and 96 bre counts. The trunk assemblies are very robust due to its central strength element and the aramid yarns, but have still a small diameter of maximum 6.4 mm and a small bending radius of maximum 65 mm. The very exible MPO fan-out is easy to install in a patch panel. Additional features are a pulling eye and a protective tube. The slim Pre-Term is available as a 12 core assembly. The small diameter of this solution makes it the preferred solution when space constraints in the cable trays and the racks are key concerns. To allow the customer the full choice of conguration options cable assemblies are offered with both normal and low loss connectors. The assemblies are available in both LANmark-OF OS2, OM3 and OM4. Plug&Play Patch Panel and modules The new Plug&Play patch panels accommodate high density patching with installation of up to 4 Plug&Play modules. A maximum of 96 LC connections can be installed in one height unit. The patch panels are sliding and have an integrated patch cord guide that sits in front of the modules. 03/12/10 - http://www.nexans.co.uk Page 177 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] One patch panel (N441.2MPP) is optimised for the installation of the slim Pre-Term. The newly introduced Plug&Play patch panel (N439.3MPP) has optimised slots in the back of the panel for the xation of the Pre-Term trunks with cable glands. The modules are available in 3 congurations: 12 SC, 12 LC and 24 LC. Modules with 24 LC connections support very high density solutions, while a module with 12 LC adaptors facilitates the patching. Modules are available in Singlemode OS2 and multimode LANmark-OF OM4, both in normal LANmark-OF MPO connectivity and low loss performance. 03/12/10 - http://www.nexans.co.uk Page 178 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2, OM3 and OM4 • • • • • • • • • Factory terminated MPO-MPO bre assembly Flexible fan-out for ease of installation in patch panel Small cable diameter reduces required data centre space Polarity in optical channel is easily maintained by its advanced design Only one type of patch cords and one type of cassettes required Fibre count between 12 and 96 Strong bre assembly with pulling eye Fibre type: Singlemode (OS2), OM3 and OM4 LANmark-OF MPO and low loss MPO connectivity performance Description MPO-MPO Pre-Term characteristics The Pre-Term is based on an advanced Micro-Bundle design for the cable. The central strength element and the aramid yarns result in a mechanical strong cable, while the Micro-Bundle allow to reduce the diameter of the cable. This round cable design facilitates the installation of the MPO-MPO Pre-Term: the small bending radius in any direction eliminates the problems of preferential bending associated with traditional ribbon MPO cables. The small diameter of 5.4 mm for cables up to 48 bres and of 6.4 mm for the cable with 96 bres of the cable reduces signicantly the expensive space required for cabling in a data centre and facilitates the airow. The small diameter also reduced the weight of the cable putting less requirements on the cable trays. The Pre-Term is delivered with protecting tubes around the installed MPOconnectors and with a pulling eye on one side. This pulling eye is connected to the internal strength element of the cable. The MPO fan-out starts at 50 cm from the cable grand and every next connector is 12 cm further away from the cable gland. For the 96 core the MPO connectors are grouped by 2 for easy installation in the patch panel and the distance between 2 pairs of MPO connectors is 12 cm. Standards International ISO11801:2002/ A1:2008 The Pre-Term is available with OM3, OM4 and singlemode bres. The singlemode bres are according the speciactions for G652D and OS2 cables. Details on the bre specications can be found in the detailed bre datasheets. The typical value for the insertion loss for a normal loss MPO-MPO connection is 0,3 dB. The limit value is 0,6 dB measured according to standard IEC61300-3-45. The typical value for the insertion loss for a low loss MPO-MPO connection is 0,2 dB. The limit value is 0,35 dB measured according to standard IEC61300-3-45. Polarity in the optical channel during installation is guaranteed due to a pair ip bre construction. This is in agreement with standard TIA 568-B-1-7-2006 method C. It allows the continuous use of the standard patch cords eliminating the need to buy optically straight patch cords. Also polarity is maintained with the same type of cassette on both sides of the channel without the need to ip the cassette on one side. The MPO-MPO Pre-Term has standard non-pinned (female) connectors. This Mechanical resistance to impacts 10 impacts of 1 N.m Operating temperature, range -10 .. 60 °C Storage temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 179 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2, OM3 and OM4 matches with the pinned (male) connectors in the MPO cassettes. The Pre-Term meets the requirements for ame non propagation (IEC 60332-1) and re non-propagation (IEC 60332-3). The outer jacket of the pre-term is LSZH. The MPO-MPO Pre-Term are custom made to the required customer length. Consistent quality In order to produce high quality, reliable pre-terminated multi-bre cables, there are a number of physical characteristics that must be addressed. Therefore, all LANmark-OF MPO-MPO Pre-Term are fully terminated and tested in a quality assured factory environment. They are delivered with these test results. Characteristics Mechanical characteristics Maximum tensile load Max. Load. Long Term Crush resistance (IEC 60794-1-E3) Mechanical resistance to impacts Usage characteristics Operating temperature, range Storage temperature, range Fire retardant Flame retardant Mechanical resistance to impacts 10 impacts of 1 N.m 1000 N 250.0 N 100 N/cm 10 impacts of 1 N.m -10 .. 60 °C -20 .. 60 °C IEC 60332-3 IEC 60332-1 Operating temperature, range -10 .. 60 °C Storage temperature, range -20 .. 60 °C 03/12/10 - http://www.nexans.co.uk Fire retardant IEC 60332-3 Flame retardant IEC 60332-1 Page 180 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Pre-Term Trunk for Singlemode OS2, Insertion loss for individual MPO connection OM3 and OM4 Fibre type Multimode (OM3 or OM4) Singlemode (OS2 with G652D) Normal loss connection -Typical loss 0.3 dB 0.3 dB Normal loss connection - Max loss 0.6 dB 0.6 dB Low loss connection - Typical loss 0.15 dB 0.15 dB Low loss connection - Max loss 0.35 dB 0.35 dB Meausured in manufacturing according to standard IEC 61300-3-45 N-number codication: N15A.MKKPVXXX Letter in N-number Description Variations A Fibre type 4: SM (OS2) or 5: OM3, 7: OM4 KK Fibre count 12,24, 48 or 96 P Performance Normal (S) or low loss (L) A: pulling eye one side + rst MPO at 50 cm + sequential MPO every 12 cm ( 12, 24 and 48 bres) V Fanout type XXX Length between glands 001-300 m E: pulling eye one side + rst 2 MPO at 50 cm + sequential 2 MPO every 12 c m (96 bres) Example: N155.M48LA050: LANmark-OF MPO-MPO Pre-Term with 48 OM3 bres, low loss connectors, pulling eye on one side, rst MPO connector at 50 cm from cable gland and with a length of 50 m between the cable glands Cable Characteristics Fibre count Cable Daimeter Cable Weight (kg/km) 12F/24F/48F 96F 5.4 mm 6.4 mm 31 kg 50 kg Minimum bending radius during installation 80 mm 100 mm Minimum bending radius installed 65 mm 65 mm 03/12/10 - http://www.nexans.co.uk Page 181 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2), OM3 and OM4 • • • • • • • • Factory terminated MPO-MPO bre assembly Easy installation of Pre-Term since assembly can bend in any direction. Small diameter of cable to reduce data centre space Polarity in optical channel is easily maintained by its advanced design Only one type of patch cords and one type of cassettes required 12 bres Fibre type: Singlemode (OS2), OM3 and OM4 Normal and low loss connectivity Description MPO-MPO Pre-Term characteristics The round cable design facilitates the installation of the MPO-MPO Pre-Term: the small bending radius of only 30 mm in any direction eliminates the problems of preferential bending associated with traditional ribbon MPO cables. Polarity in the optical channel during installation is guaranteed due to a pair ip bre construction. This is in agreement with standard TIA 568-B-1-7-2006 method C. It allows the continuous use of the standard patch cords eliminating the need to buy optically straight patch cords. Also polarity is maintained with the same type of cassette on both sides of the channel without the need to ip the cassette on one side. The Pre-Term is available with OM3, OM4 and singlemode bres. The singlemode bres are according to the specications for G652D and OS2 cables. Details on the bre specications can be found in the detailed bre datasheets. The typical value for the insertion loss for a normal loss MPO-MPO connection is 0,3 dB. The limit value is 0,6 dB measured according to standard IEC61300-3-45. The typical value for the insertion loss for a low loss MPO-MPO connection is 0,2 dB. The limit value is 0,35 dB measured according to standard IEC61300-3-45. Mechanical characteristics of the Pre-Term are conform to the IEC-60794-20 standard for indoor cables. The small diameter of 2.5 mm of the cable reduces signicantly the expensive space required for cabling in a data centre and facilitates the airow. The MPO-MPO Pre-Term has standard non-pinned (female) connectors. This matches with the pinned (male) connectors in the MPO modules. Consistent quality In order to produce high quality, reliable pre-terminated multi-bre cables, there are a number of physical characteristics that must be addressed. Therefore, all LANmark-OF MPO-MPO Pre-Term are fully terminated and tested in a quality assured factory environment. They are delivered with these test results. Operating temperature, range 0 .. 50 °C Storage temperature, range -40 .. 60 °C Fire retardant IEC 60332-3 03/12/10 - http://www.nexans.co.uk Flame retardant IEC 60332-1 Minimum static operating bending radius 30 mm Page 182 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2), OM3 and OM4 MPO-MPO Pre-Term Benefits • • • • • • • • • • • Short & reliable manufacturing lead-time Fast installation times No specialised termination training required No consumables, termination tool kits No cable preparation necessary No cable or connector scrap No termination errors on site Delivered fully tested, labelled and documented Improved end-to-end attenuation Reduced on-site disruption and installation time Cost effective solution Operating temperature, range 0 .. 50 °C Storage temperature, range -40 .. 60 °C Fire retardant IEC 60332-3 03/12/10 - http://www.nexans.co.uk Flame retardant IEC 60332-1 Minimum static operating bending radius 30 mm Page 183 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF MPO-MPO Slim Pre-Term for Singlemode (OS2), Characteristics OM3 and OM4 Dimensional characteristics Approximate weight Outer Diameter Mechanical characteristics Maximum pulling force (IEC 60794-1-2-E1) Crush resistance (IEC 60794-1-E3) Usage characteristics Operating temperature, range Storage temperature, range Fire retardant Flame retardant Minimum static operating bending radius 5.5 kg/km 2.5 mm 400 N 50 N/cm 0 .. 50 °C -40 .. 60 °C IEC 60332-3 IEC 60332-1 30 mm Insertion loss for individual MPO connection Fibre type Multimode (OM3 or OM4) Singlemode (OS2 with G652D) Normal loss connection -Typical loss 0.3 dB 0.3 dB Normal loss connection - Max loss 0.6 dB 0.6 dB Low loss connection - Typical loss 0.15 dB 0.15 dB Low loss connection - Max loss 0.3 dB 0.3 dB Measured in manufacturing according to standard IEC 61300-3-45 N-number codication: N15A.P12QVXXX Letter in N-number Description Variations A Fibre type 4: SM (OS2) or 5: OM3, 7: OM4 Q Performance Normal (S) or low loss (L) V Fanout type Default (N): No pulling eye and protection tube XXX Length between glands 001-300 m Example: N155.P12LN050: LANmark-OF MPO-MPO Slim Pre-Term with 12 OM3 bres, low loss connectors with a length of 50 m between the cable glands. 03/12/10 - http://www.nexans.co.uk Page 184 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Plug&Play Patch Panels • • • • Optical patch panels that holds up 4 MPO modules in 1 HU Sliding patch panels for ease of installation, upgrade and maintenance High density connectivity: up to 48 SC or 96 LC depending on module type. Labelling front for port identication and patch cord management within 1 HU Description Plug&Play Concept Description The Nexans' Plug and Play concept is specically designed for installation in data centres where the high density, integrated patch cord guide and enhanced installation benets of the patch panel meet the key requirements for implementation. It allows quick changes with limited down time, easy migration to other applications and a transition path to 40G. The Plug&Play system consists of 3 subcomponents: Plug&Play modules, the MPO-MPO Pre-Term and the Plug&Play patch panel. The modules provide the transition between the MPO-MPO Pre-Term and the active devices: the Pre-Term connects to the back of the module and inside the module the bres are spread out towards the SC/LC connectors at the front. Modules are available in a wide variety of port counts and connector style. Plug&Play Patch Panel Characteristics Standards International ISO/IEC 11801 The Nexans unique patch panel design allows to hold up to 4 MPO cassettes in 1HU of the distribution rack. Depending on the type of the module a high density of up to 96 bre connections can be accommodated. The new patch cord guide sits in front of the modules and allows the patch cords to be managed within the same 1 HU saving expensive rack space. The patch cord guide also provides a labelling facility to identify connections. Additional labelling is provided by printed port numbers on the modules. The newly developed trays slide for improved access to install new modules and to x the MPO-MPO Pre-Term easily. The front of the patch panel can be xed in a ush or recessed position in the rack. The N439.2MPP is optimised for installation of the trunk MPO-MPO Pre-Term: the cable glands of the Pre-Term allow a fast and solid xation of the cable. There is ample space inside the patch panel to organise the exible fan-out of the MPO-MPO Pre-Term. The N441.2MPP is optimised for installation of multiple slim Pre-Terms. The slim Pre-Terms are xed with tie wraps. Panels are fully painted in black for a professional look and feel. Blank llers (N441.2MBP) are available as separate accessories for unused positions to give a nished look. 03/12/10 - http://www.nexans.co.uk Page 185 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF [email protected] Module • • • • • • [email protected] module with 12SC, 12 LC or 24 LC connections Available with LANmark-OF [email protected] connectivity and low loss connectivity grade Available in LANmark-OF OM4 multimode and LANmark-OF OS2 singlemode Module can be easily mounted into Nexans' Plug&Play patch panel High density: 4 modules t into 1U [email protected] modules are pre-installed and 100 % factory tested Description The [email protected] system consists of 3 subcomponents: the MPO modules, the MPO-MPO Pre-Terms and the Plug&Play patch panel. The central component is the pre-installed [email protected] module. The MPO connector at the back of the module connects at once 12 bres of the MPO-MPO Pre-Term. Inside the module the bres are spread out towards the SC/LC adaptors at the front. [email protected] Module Characteristics Up to 4 [email protected] modules can be installed quickly into the Plug&Play patch panel with push rivets. With these 4 modules a medium density of 48 SC or 48 LC connections within 1U can be achieved. With the 24 LC high density module a maximum of 96 LC connections within 1U is also possible. Standards International ISO/IEC 11801 The insertion loss for the LANmark-OF [email protected] module is 0,9 dB measured according to standard IEC 61300-3-45. The insertion loss for the LANmark-OF [email protected] low loss module is 0,6 dB measured according to standard IEC 61300-3-45. The modules are available with OM4 bres for multimode and are backwards compatible with OM3 bres. The singlemode module has G652D bres for OS2 compatibility. The wiring inside the module is straight. This allows to maintain polarity in the MPO-link together with the pair-wise bre ip inside the MPO-MPO Pre-Term according to method C from standard TIA 568-B-1-7-2007. Since all connectivity is factory installed and factory tested installation times are short for a quick deployment or for frequent changes. The [email protected] module has standard pinned (male) connectors. This matches perfectly with the non-pinned (female) connectors of the MPO-MPO Pre-Term. 03/12/10 - http://www.nexans.co.uk Page 186 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF [email protected] Module N-numbers for Plug&Play Modules N441.2M24LC4 LANmark-OF Plug&Play Module 24 LC OM4 OM3/OM4 N441.2M12LC4 LANmark-OF Plug&Play Module 12 LC OM4 N441.2M12SC4 LANmark-OF Plug&Play Module 12 SC OM4 MPO Module N441.2M24LC0 LANmark-OF Plug&Play Module 24 LC Singlemode SM OS2 N441.2M12LC0 LANmark-OF Plug&Play Module 12 LC Singlemode N441.2M12SC0 LANmark-OF Plug&Play Module 12 SC Singlemode OM3/OM4 MPO Low Loss Module SM OS2 N441.2L24LC4 LANmark-OF Plug&Play Low Loss Module 24 LC OM4 N441.2L12LC4 LANmark-OF Plug&Play Low Loss Module 12 LC OM4 N441.2L12SC4 LANmark-OF Plug&Play Low Loss Module 12 SC OM4 N441.2L24LC0 LANmark-OF Plug&Play Low Loss Module 24 LC Singlemode N441.2L12LC0 LANmark-OF Plug&Play Low Loss Module 12 LC Singlemode N441.2L12SC0 LANmark-OF Plug&Play Low Loss Module 12 SC Singlemode 03/12/10 - http://www.nexans.co.uk Page 187 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre Patch Panels LANmark-OF offers cutting edge hardware products including patch panels, zone distribution boxes and outlets. Each product has been thoroughly developed to ensure best system offering while meeting stringent international standards. Modular concept The fully modular design allows mixing of different Snap-in adaptor types : LC, MT-RJ and SC. Benets: up to 24 bres for the Zone Distribution Box and 48 for the Patch Panel. Both are compatible for loose tube and tight buffer cables. 03/12/10 - http://www.nexans.co.uk Page 188 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Sliding Patch Panels • • • • • Empty OF patch panels with sliding mechanism. Suitable for direct termination or splicing. Available in two versions 24 ST or modular Duplex or simplex SC, LC, or MT-RJ snap-ins. Inner sliding to respect bending radius of patch cord. LANmark look. Description Application Accepting the range of ST couplers or LANmark-OF snap-ins, these patch panels with sliding mechanism facilitate front side installation. Compatibility Suitable for tight buffer cables (direct termination) , Loose tube cables using Splice Cassette / pigtailed terminations. Accepts pre-terminated cable assemblies. Installation • • • • 19" width. 1U Accommodates 24 ST or 24 LANmark-OF snap-ins (or 12DSC). 2 positions : ush or recessed with respect of cable bend radius. Comes with marking strips to number and categorise ports. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 189 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Sliding Patch Panels Product List Nexans ref. N441.204 Nouveauté N441.203 Nouveauté N441.201 =Make to order, =Make to stock Name LANmark-OF Patch Panel Snap-In Sliding Black LANmark-OF Patch Panel Snap-In Sliding White LANmark-OF Patch Panel 24 ST Sliding White = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 190 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Sliding Preloaded Patch Panels • • • • • • Preloaded patch panels with adaptors for fast installation in data centres High density connectivity: up to 48 SC or 96 LC. Sliding and tilting patch panel for ease of installation, upgrade and maintenance Optimised for installation of Pre-Term with a cable gland and bre management features Improved splice cassettes with lifting functionality for improved ease of installation and inspection Labelling facility for port identication and patch cord management within 1 U Description The new pre-loaded patch panel is specically designed for installation in data centres where the high density, integrated patch cord guide and enhanced installation benets of the patch panel meet the key requirements for implementation. The patch panels are pre-loaded with SC or LC adaptors and are available in medium and high density versions. The medium density patch panel provides 24 SC or 48 LC connections, while the high density version has 48 SC or 96 LC connections. Singlemode and multimode versions are available. The new patch cord guide sits in front of the adaptors and allows the patch cords to be managed within the same 1 U saving expensive rack space. The patch cord guide also provides a labelling facility to identify connections. Additional labelling is provided by printed port numbers on the adaptor plate. The newly developed chassis of the patch panel can be removed from the rack completely to ease installation of direct terminated or spliced bre and faster installation of pre-terminated cables. The tray tilts and slides for improved access to the installed bres for inspection. Standards International ISO/IEC 11801 The pre-loaded patch panel has extended cable management with multiple entries to provide maximum exibility. It accommodates both cable glands and tie wraps for strain relief of the cables. The cable gland sizes are 20 mm (8x) and 25 mm (2x). For improved bre management the bres can be arranged in 4 separate loops for added exibility and organisation. The support bases and the rings for these 4 loops are included. The patch panel chassis has multiple, specially designed, slots at the rear to x the cable glands of Nexans’ pre-terminated cables. There is ample space inside the patch panel to organise the exible fan-out of the pre-terminated cables. Up to 4 splice cassettes (N890.090 and N890.091) can be installed inside the tray of the patch panel. Only one cover (N890.093) is required to close the splice cassettes at the top. The bottom splice cassette is xed with screws to the chassis of the patch panel. Splice cassettes are xed with hinges to the cassette below and with such an installation the splice cassettes can be lifted and tilted for improved access to the splices inside the patch panel. This facilitates the inspection of the splices after installation. Each splice cassette for heat shrink protectors (N890.090) can accommodate 12 splices allowing a maximum of 48 splices for the complete patch panel. The splice cassette for aluminium protectors (N890.091) has a maximum of 24 splices resulting in a maximum of 96 splices per patch panel. N890.091 can only be used with maxistrip pigtails and cables with 250 um bres. Splice cassettes are not included in the patch panel. The front adaptor plate can be xed in a ush or recessed position in the rack using the adjustable side brackets. When the panel is installed recessed the distance between the rack vertical and the rear of the panel is 288 mm. The front cord management projection is 67 mm. When the panel is installed ush the distance between the rack vertical and the rear of the panel is 248 mm. The front cord management projection is 107 mm. 03/12/10 - http://www.nexans.co.uk Page 191 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Sliding Preloaded Patch Panels Panels are fully painted in black for a professional look and feel. 03/12/10 - http://www.nexans.co.uk Page 192 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Sliding Preloaded Patch Panels Available versions and N-numbers N-number Description SC or LC # connections SM or MM N439.2B48LCMM LANmark-OF Preloaded Patch Panel 48 LC Multimode Sliding Black LC 48 N439.2B48LCSM LC 48 SM LC 96 MM LANmark-OF Preloaded Patch Panel 48 LC Singlemode Sliding Black N439.2B96LCMM LANmark-OF Preloaded Patch Panel 96 LC Multimode Sliding Black N439.2B96LCSM LANmark-OF Preloaded Patch Panel 96 LC Singlemode Sliding Black MM LC 96 SM N439.2B24SCMM LANmark-OF Preloaded Patch Panel 24 SC Multimode Sliding Black SC 24 MM N439.2B24SCSM LANmark-OF Preloaded Patch Panel 24 SC Singlemode Sliding Black SC 24 SM N439.2B48SCMM LANmark-OF Preloaded Patch Panel 48 SC Multimode Sliding Black SC 48 MM N439.2B48SCSM LANmark-OF Preloaded Patch Panel 48 SC Singlemode Sliding Black SC 48 SM 03/12/10 - http://www.nexans.co.uk Page 193 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-OF Fixed Patch Panel • • • • • Empty OF patch panel without sliding mechanism. Suitable for direct termination or splicing. Can be used as splitter box. Available in two versions 24ST and 24 SC. Three positions faceplate for patch cord bending radius. Description Application Nexans Essential 1U Optical Fibre Patch Panel has been designed to support : • up to 24 ST ports or • up to 12 Dual SC ports. It combines a cost effective design with high port density. It is suitable for tight buffer cables (direct termination) or loose tube cables using splice tray (N890.001). It also can be used as a splitter(*) Features • • • • 19" width Two versions ST and SC Blind face plates are available. 3 positions : -ushed -15 mm recessed Standards -30 mm recessed International ISO/IEC 11801 • Easy identication : couplers are numbered on the face plate. • Cable entrance is possible through a cable gland (PG16) or through a rectangular opening (Using tie wraps). • Cage-nuts as well as bre holders are included. (*) splitter allows to split multitube cable to at most 6 Nexans E-ssential OF Patch Panels. For use as splitter, you need: -Splitter tube (N890.044) -Cable gland for splitter (N890.043) -Blind plate (N441.132) 03/12/10 - http://www.nexans.co.uk Page 194 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Essential-OF Fixed Patch Panel Characteristics Dimensional characteristics Heightunit Width Depth Usage characteristics Component function Product List Nexans ref. N441.122 N441.121 1U 19 in 233 mm Patch panel Name Essential-OF Patch Panel 24 SC White Essential-OF Patch Panel 24 ST White Connector type SC ST = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 195 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Outlets 03/12/10 - http://www.nexans.co.uk Page 196 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Zone Distribution box • Empty ZD box optical ber • Suitable for direct termination or splicing. Description Application • Designed for the installation of zone wiring, bre to the ofce and to the desk Compatibility Suitable for tight buffer cable (direct termination) or loose tube using splice tray Compatible with all LANmark-OF accessories Installation The OF zone distribution box is easy to install in the ceiling, false oor or on the wall with four xation points in the bottom plate. To enter the cable there is a pre-perforated hole for a cable gland PG 16 foreseen, at the backside. There is a xation point for the Nexans splice tray. Standards International ISO/IEC 11801 Printed numbering system on the cover 03/12/10 - http://www.nexans.co.uk Page 197 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Zone Distribution box Characteristics Dimensional characteristics Depth Height Width Usage characteristics Field of application Packaging 200 mm 40 mm 230 mm Indoor Box Characteristics ZD box Connector type Product List Nexans ref. N521.630 LC Name LANmark-OF modular Zone distribution box empty = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 198 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Structural Hardware • • • • • For all 45x45mm ttings Fits Surface Mount Boxes, Cover plates and Ducts Outlets include labeling and shutters Suitable for all snap-in adaptors. Easy click-in mechanism. Description Application This range of outlets is suitable for any environment: ducts, cover plates and surface mount boxes (including 45 ttings). The range features Snap-in adaptors for fast and easy installation. For the specic information on the Snap-in adaptors , refer to the corresponding datasheets. Guarantees • All plastic material is UL 94V0 Installation These modular outlets t into a complete range of international 45x45 covering plates and surface mount boxes. For easy management and identication, the outlets are include an integrated outlet labelling system using transparent windows. The Snap-in connectors are inserted into the modular outlet by a simple click-in mechanism. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 199 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Structural Hardware Product List Nexans ref. N420.035 Nouveauté Name Modular OF Splicing Outlet 45X45 for 2 Snap-in adaptors = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 200 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Patch Cords 03/12/10 - http://www.nexans.co.uk Page 201 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Patch Cords Description Application Nexans LANmark-OF optical bre patchcords have been designed for applications where a high level of optical features is required. • Suitable for use in cabinets to connect patch panels/active equipments to active equipments. • Suitable for use in the work area to connect the work station to the wall outlet (Fibre To The Desk). Applications support : • • • • • • • • • • • • Fast Ethernet 100 base FX 1Gbase SX 1Gbase LX 10Gbase SR 10Gbase LW 10Gbase LX4 10Gbase LR 10Gbase LRM Fibre Channel Serial 1G Fibre Channel Serial 2G Fibre Channel Serial 4G Fibre Channel Serial 10G Standards International ISO/IEC 11801 Performance Nexans LANmark-OF patchcords are available in all standardised optical bre classes, multimode and single mode.The MM62.5 version is designed for use in an OM1 compliant system, the MM50 version for OM2 systems and the MM50 OM3 version for OM3 systems. The singlemode version is OS2 compliant. The multimode versions can be used in laser optimised systems using the LANmarkOF xt cables. Design Nexans LANmark-OF patchcords designed according the "Cross-Over" wiring principle to improve eld installation (A1-B2, B1-A2). Guarantees Nexans LANmark-OF patchcords are guaranteed to support LED based applications as well as Laser based applications.They are covered by Nexans warranty as described in the General Terms and Conditions. Characteristics Construction characteristics Armour type Outer sheath Operating temperature, range -10 .. 50 °C Aramid yarn LSZH-FR Fire retardant IEC 60332-3 Cat.C 03/12/10 - http://www.nexans.co.uk Minimum static operating bending radius 40 mm Page 202 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Patch Cords Mechanical characteristics Maximum pulling force by laying Crush resistance (IEC 60794-1-E3) Usage characteristics Operating temperature, range Fire retardant Minimum static operating bending radius Product List Nexans ref. N123.2LLO2 N123.2LLO5 N123.2CLO2 N123.2CLO5 N123.2LTO2 N123.2LTO5 N123.2CCO2 N123.2CCO5 N123.2CTO2 N123.2CTO5 N123.2TTO2 N123.2TTO5 N123.2MLO2 N123.2MLO5 N123.2MCO2 N123.2MCO5 N123.2MTO2 0.2 kN 250 N/cm -10 .. 50 °C IEC 60332-3 Cat.C 40 mm Name Length (m) LANmark-OF Patch cord Multimode 50/125 2LC 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2LC 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 2LC 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2LC 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 2LC 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2LC 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 2SC 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2SC 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 2SC 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2SC 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 2ST 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 2ST 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 MT-RJ 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 MT-RJ 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 MT-RJ 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 MT-RJ 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 MT-RJ 2ST LSZH Orange 2m 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 =Make to order, Fiber optic type OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance = Make to order, Operating temperature, range -10 .. 50 °C Fire retardant IEC 60332-3 Cat.C 03/12/10 - http://www.nexans.co.uk =Make to stock Connector type LC LC SC-LC SC-LC LC LC SC SC SC SC ST ST MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ = Make to stock Minimum static operating bending radius 40 mm Page 203 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Patch Cords Nexans ref. N123.2MTO5 N123.2MMO2 N123.2MMO5 N123.5LLO2 N123.5LLO5 N123.5CLO2 N123.5CLO5 N123.5LTO2 N123.5LTO5 N123.5CCO2 N123.5CCO5 N123.5CTO2 N123.5CTO5 N123.5TTO2 N123.5TTO5 N123.5MLO2 N123.5MLO5 N123.5MCO2 N123.5MCO5 N123.5MTO2 N123.5MTO5 N123.5MMO2 N123.5MMO5 Name Length (m) LANmark-OF Patch cord Multimode 50/125 MT-RJ 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 MT-RJ MT-RJ LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 MT-RJ MT-RJ LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2LC - 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2SC - 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2SC - 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2SC - 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2SC - 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 2ST - 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 2ST - 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - MT-RJ LSZH Orange 2m LANmark-OF Patch cord Multimode 50/125 OM3 MTRJ - MT-RJ LSZH Orange 5m 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 Fiber optic type OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM2 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance OM3 50/125 Extended Distance = Make to order, Operating temperature, range -10 .. 50 °C Fire retardant IEC 60332-3 Cat.C 03/12/10 - http://www.nexans.co.uk Connector type MT-RJ MT-RJ MT-RJ LC LC SC-LC SC-LC LC LC SC SC SC SC ST ST MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ = Make to stock Minimum static operating bending radius 40 mm Page 204 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Patch Cords Nexans ref. N123.0LLO2 N123.0LLO5 N123.0CLO2 N123.0CLO5 N123.0LTO2 N123.0LTO5 N123.0CCO2 N123.0CCO5 N123.0CTO2 N123.0CTO5 N123.0TTO2 N123.0TTO5 N123.0MLO2 N123.0MLO5 N123.0MCO2 N123.0MCO5 N123.0MTO2 N123.0MTO5 N123.0MMO2 N123.0MMO5 N123.4LLY2 N123.4LLY5 N123.4CLY2 Name Length (m) LANmark-OF Patch cord Multimode 62,5/125 2LC 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2LC 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 2LC 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2LC 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 2LC 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2LC 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 2SC 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2SC 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 2SC 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2SC 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 2ST 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 2ST 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2LC LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2LC LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2SC LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2SC LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2ST LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - 2ST LSZH Orange 5m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - MT-RJ LSZH Orange 2m LANmark-OF Patch cord Multimode 62,5/125 MT-RJ - MT-RJ LSZH Orange 5m LANmark-OF Patch cord Singlemode OS2 2LC - 2LC LSZH Yellow 2m LANmark-OF Patch cord Singlemode OS2 2LC - 2LC LSZH Yellow 5m LANmark-OF Patch cord Singlemode OS2 2LC 2SC LSZH Yellow 2m 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 Fiber optic type OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance OM1 62.5/125 Extended Distance Fire retardant IEC 60332-3 Cat.C 03/12/10 - http://www.nexans.co.uk LC LC SC-LC SC-LC LC LC SC SC SC SC ST ST MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ MT-RJ 2 SM (G.652D) LC 5 SM (G.652D) LC 2 SM (G.652D) SC-LC = Make to order, Operating temperature, range -10 .. 50 °C Connector type = Make to stock Minimum static operating bending radius 40 mm Page 205 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Patch Cords Nexans ref. N123.4CLY5 N123.4LTY2 N123.4LTY5 N123.4CCY2 N123.4CCY5 N123.4CTY2 N123.4CTY5 N123.4TTY2 N123.4TTY5 N123.7LLO2 Name Length (m) Fiber optic type Connector type 5 SM (G.652D) SC-LC 2 SM (G.652D) LC 5 SM (G.652D) LC 2 SM (G.652D) SC 5 SM (G.652D) SC 2 SM (G.652D) SC 5 SM (G.652D) SC 2 SM (G.652D) ST 5 SM (G.652D) ST 2 OM4 50/125 LC LANmark-OF Patch cord Singlemode OS2 2LC 2SC LSZH Yellow 5m LANmark-OF Patch cord Singlemode OS2 2LC - 2ST LSZH Yellow 2m LANmark-OF Patch cord Singlemode OS2 2LC - 2ST LSZH Yellow 5m LANmark-OF Patch cord Singlemode OS2 2SC 2SC LSZH Yellow 2m LANmark-OF Patch cord Singlemode OS2 2SC 2SC LSZH Yellow 5m LANmark-OF Patch cord Singlemode OS2 2SC 2ST LSZH Yellow 2m LANmark-OF Patch cord Singlemode OS2 2SC 2ST LSZH Yellow 5m LANmark-OF Patch cord Singlemode OS2 2ST - 2ST LSZH Yellow 2m LANmark-OF Patch cord Singlemode OS2 2ST - 2ST LSZH Yellow 5m LANmark-OF Patchcord Multimode 50/125 OM4 2LC - 2LC LSZH Orange 2m = Make to order, = Make to stock Optical Performance Patch Cords Fibre type Connector Polishing Insertion loss max. Return loss min. Multimode ST-SC-LC PC 0,3 dB > 30 dB Multimode MT-RJ PC 0,3 dB NA Singlemode ST-SC-LC PC 0.3 dB > 40 dB Singlemode SC-LC APC 0,3 dB > 55 dB Singlemode MT-RJ NA NA NA Operating temperature, range -10 .. 50 °C Fire retardant IEC 60332-3 Cat.C 03/12/10 - http://www.nexans.co.uk Minimum static operating bending radius 40 mm Page 206 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Pigtails & Splicing Materials 03/12/10 - http://www.nexans.co.uk Page 207 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Aluminium Protectors Preloaded Sliding Panel Description Family Characteristics • Family of patch panel accessories for termination of a cable with fusion splicing techniques. • Provides management for cable and pigtails within the bre patch panel. • The cassette protects the fusion splices and holds them in position. • The splice cassette can retain up to 24 fusion splices. • Four trays can be stacked inside the patch panels resulting in a maximum capacity of 96 fusion splices in a patch panel. • Splice cassettes are xed to each other at the back of the cassettes with the provided hinges. This feature facilitates the inspection after installation since the cassettes can be lifted and tilted. • The larger cassettes facilitates 2 rings of routing: an inner ring for the bres of the pigtails and an outer ring for the bres of the cable. • Splicing with Aluminium protectors can be used for loose tube cables, i.e. bres with a 250 um coating. Aluminium protectors can not be used with tight buffer cables, i.e. bres with a 900 um coating. • Splicing with Aluminium protectors can be used for maxistrip pigtails. • LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of loose tube cable into different splice cassettes. • These splice cassettes can be installed in the LANmark-OF and LANsense-OF sliding preloaded patch panels (N439.2B* and N883.2B*). 03/12/10 - http://www.nexans.co.uk Standards International ISO11801:2002/ A1:2008 Page 208 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Aluminium Protectors N890.091: LANmark-OF Splice Cassette 24 Aluminium Protection Sliding Preloaded Panel Preloaded Sliding Panel • • • • Splice Cassette for management of splices with Aluminium protectors. Provides support for 2*12 splices with Aluminium protectors. Designed for use with loose tube cables (250 um coated bres). Designed for use with maxistrip pigtails. N890.003: LANmark-OF Fusion Splice Aluminium Protectors • • • • • • LANmark OF- accessories to complete the splicing system with Aluminium protectors 150 pieces per bag Lenght: 30 mm Compatible with loose tube cables (250 um coated bres) Compatible with maxistrip pigtails Designed for Nexans’ splice cassette for 24 Aluminium fusion splice protectors (N890.091) N890.092: LANmark-OF Cover Splice Cassette Sliding Pre-loaded Panel • LANmark-OF accessories to complete splice cassette system. • LANmark-OF splice cassette cover compatible with N890.090 and N890.091. • When the splice cassettes are stacked only the top splice cassette requires a cover. 03/12/10 - http://www.nexans.co.uk Page 209 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Aluminium Protectors Preloaded Sliding Panel N890.004: Tool for Aluminium Fusion Splice Protectors • A crimp tool for easy installation of the Aluminium fusion splice protectors. • Compatible with Nexans Aluminium fusion splice protector (N890.003). 03/12/10 - http://www.nexans.co.uk Page 210 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Aluminium Protectors Snap-In Panel Description Family Characteristics • Family of patch panel accessories for termination of a cable with fusion splicing techniques. • Provides management for cable and pigtails within the bre patch panel. • The cassette protects the fusion splices and holds them in position. • The splice cassette can retain up to 24 fusion splices. • Four trays can be stacked inside the patch panels resulting in a maximum capacity of 96 fusion splices in a patch panel. • Splicing with Aluminium protectors can be used for loose tube cables, i.e. bres with a 250 um coating. Aluminium protectors can not be used with tight buffer cables, i.e. bres with a 900 um coating. • Splicing with Aluminium protectors can be used for maxistrip pigtails. • LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of loose tube cable into different splice cassettes. • These splice cassettes can be installed in the LANmark-OF Snap-In Patch Panel (N441.203 and N441.204) and the LANmark-OF Zone Distribution Box (N521.630). 03/12/10 - http://www.nexans.co.uk Standards International ISO11801:2002/ A1:2008 Page 211 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Aluminium Protectors N890.096: LANmark-OF Splice Cassette 24 Aluminum Protectors Snap-In Panel Snap-In Panel • • • • Splice Cassette for management of splices with Aluminium protectors. Provides support for 2*12 splices with Aluminium protectors. Designed for use with loose tube cables (250 um coated bres). Designed for use with maxistrip pigtails. N890.003: LANmark-OF Fusion Splice Aluminium Protectors • • • • • • LANmark OF- accessories to complete the splicing system with Aluminium protectors 150 pieces per bag Lenght: 30 mm Compatible with loose tube cables (250 um coated bres) Compatible with maxistrip pigtails Designed for Nexans’ splice cassette for 24 Aluminium fusion splice protectors (N890.096) N890.097: Cover for Splice Cassette Snap-In Panel • LANmark-OF accessories to complete splice cassette system. • LANmark-OF splice cassette cover compatible with N890.095 and N890.096. 03/12/10 - http://www.nexans.co.uk Page 212 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] • LANmark-OF Splicing Accessories with Aluminium Protectors When the splice cassettes are stacked only the top splice cassette requires a cover. Snap-In Panel N890.004: Tool for Aluminium Fusion Splice Protectors • A crimp tool for easy installation of the Aluminium fusion splice protectors. • Compatible with Nexans Aluminium fusion splice protector (N890.003). 03/12/10 - http://www.nexans.co.uk Page 213 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors Preloaded Sliding Panel Description Family Characteristics • Family of patch panel accessories for termination of a cable when using fusion splicing techniques. • The cassette protects the fusion splices and holds them in position. • The splice cassette can retain up to 12 fusion splices. • Four trays can be stacked inside the patch panels resulting in a maximum capacity of 48 fusion splices in a patch panel. • Splice cassettes are xed to each other at the back of the cassettes with the provided hinges. This feature facilitates the inspection after installation since the cassettes can be lifted and tilted. • The large cassettes facilitates 2 rings of routing: an inner ring for the bres of the pigtails and an outer ring for the bres of the cable. • Splicing with heat shrink protectors can be used for both tight buffer and loose tube cables, i.e. heat shrink protectors are compatible with both 250 and 900 um coated bres. • Splicing with heat shrink protectors can be used for both maxistrip and tight buffer pigtails. • LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of loose tube cable into different splice cassettes. • These splice cassettes can be installed in the LANmark-OF and LANsense-OF sliding preloaded patch panels (N439.2B* and N883.2B*). 03/12/10 - http://www.nexans.co.uk Standards International ISO11801:2002/ A1:2008 Page 214 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors N890.090: LANmark-OF Splice Cassette 12 Heat Shrink Protection Sliding Preloaded Panel Preloaded Sliding Panel • • • • Splice cassette for management of splices with heat shrink protectors. Provides support for 2*6 heat shrink splice protectors. Designed for use with both loose tube and tight buffer cables, i.e. 250 and 900 um coated bres. Designed for use with both maxistrip and tight buffer pigtails. N890.021: LANmark-OF Fusion Splice Heat Shrink protectors (45mm) • • • • • • LANmark OF-accessories to complete the splicing system with heat shrink protectors 100 pieces per bag Lenght: 45mm Compatible with tight buffer or loose tube cables, i.e. 250 and 900 um coated bres. Compatible with tight buffer and maxistrip pigtails Designed for Nexans’ splice cassette for 12 heat shrink fusion splice protectors (N890.090) N890.092: LANmark-OF Cover Splice Cassette Sliding Preloaded Panel • LANmark-OF accessories to complete splice cassette system. • LANmark-OF splice cassette cover compatible with N890.091 and N890.092. • When the splice cassettes are stacked only the top splice cassette requires a cover. 03/12/10 - http://www.nexans.co.uk Page 215 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors Preloaded Sliding Panel 03/12/10 - http://www.nexans.co.uk Page 216 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors Snap-In Patch Panel Description Family Characteristics • Family of patch panel accessories for termination of a cable when using fusion splicing techniques. • The cassette protects the fusion splices and holds them in position. • The splice cassette can retain up to 12 fusion splices. • Four trays can be stacked inside the patch panels resulting in a maximum capacity of 48 fusion splices in a patch panel. • Splicing with heat shrink protectors can be used for both tight buffer and loose tube cables, i.e. heat shrink protectors are compatible with both 250 and 900 um coated bres. • Splicing with heat shrink protectors can be used for both maxistrip and tight buffer pigtails. • LANmark-OF Bend Limiting Tube (N890.145) can be used to split up bres of loose tube cable into different splice cassettes. • These splice cassettes can be installed in the LANmark-OF Snap-In Patch Panel (N441.203 and N441.204) and the LANmark-OF Zone Distribution Box (N521.630). 03/12/10 - http://www.nexans.co.uk Standards International ISO11801:2002/ A1:2008 Page 217 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors N890.095: LANmark-OF Splice Cassette 12 Heat Shrink Protectors Snap-In Panel Snap-In Patch Panel • • • • Splice cassette for management of splices with heat shrink protectors. Provides support for 2*6 heat shrink splice protectors. Designed for use with both loose tube and tight buffer cables, i.e. 250 and 900 um coated bres. Designed for use with both maxistrip and tight buffer pigtails. N890.021: LANmark-OF Fusion Splice Heat Shrink protectors (45mm) • • • • • • Lanmark OF-accessories to complete the splicing system with heat shrink protectors 100 pieces per bag Lenght: 45mm Compatible with tight buffer or loose tube cables, i.e. 250 and 900 um coated bres. Compatible with tight buffer and maxistrip pigtails Designed for Nexans’ splice cassette for 12 heat shrink fusion splice protectors (N890.095) N890.097: Cover for Splice Cassette Snap-In Panel • LANmark-OF accessories to complete splice cassette system. 03/12/10 - http://www.nexans.co.uk Page 218 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Splicing Accessories with Heatshrink Protectors LANmark-OF splice cassette cover compatible with N890.095 and N890.096. Snap-In Patch Panel • • When the splice cassettes are stacked only the top splice cassette requires a cover. 03/12/10 - http://www.nexans.co.uk Page 219 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Splice Materials Description A range of materials and accessories for splicing Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 220 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Splice Materials Product List Nexans ref. N890.145 N890.024 N890.023 N890.044 =Make to order, =Make to stock Name LANmark-OF Bend Limiting Tube LANmark-OF Fusion Splice Heat Shrink Protection (65mm) Splice Holder Splitter tube = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 221 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Pigtails Maxistrip • • • • • Maxistrip pigtail for ease of splicing and high density Insertion loss per connection: 0.3 dB maximum Factory terminated bre assembly 100 % factory tested Compatible with LANmark-OF splice cassette with heat shrink or Aluminium protection. Description Pigtail family characteristics • • • • • Fibre assembly to terminate cable with fusion splicing Available with ST, SC, LC and MTRJ connectors Suitable for use in patch panels using splice cassettes. The pigtails can be stripped in one action over a long distance of up to 1m. Insertion loss: typical value is 0.1 dB, maximum value is 0.3 dB. Fibre types • Nexans LANmark-OF pigtails are available in all standardised optical bre classes, multimode and singlemode. • The MM50 version is designed to be used in a OM3 or a OM3xt compliant system and is backwards compliant with OM2 and OM2xt systems. The outher sheath for this type of pigtail is aqua. • The MM62.5 version is designed for use in OM1 or OM1xt compliant systems. These pigtails are orange. • The singlemode version is OS2 compliant with G652d bre inside. These pigtails are yellow. • The multimode versions can be used in laser optimised systems using the LANmark-OF xt cables. Standards International ISO/IEC 11801 Compatibility and installation practices • Maxistrip pigtails are compatible with heat shrink splice cassettes (N890.095) with heat shrink protections (N890.021). • Maxistrip pigtails are compatible with splice cassettes (N890.096) with Aluminium protections (N890.021). • Maxistrip pigtails are recommended to be used with loose tube cables, i.e. with 250 um bres. When using tight buffer cables (900 um bres) additional stress on the maxistrip pigtails should be limited as much as possible • For proper alignment in the fusion splice tool the pigtail is xed on the 250 um coating after stripping the 900 um coating. Fixing the pigtail on the 900 um coating will lead to improper alignment. • In addition the pigtail needs to be stripped till the cladding around the splice area before insertion in the splice tool. Guarantuees Nexans LANmark-OF pigtails are covered by Nexans warranty as described in the General Terms and Conditions 03/12/10 - http://www.nexans.co.uk Page 222 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Pigtails Maxistrip Optical performance pigtails Fibre type Connector Polishing Insertion loss max. Return loss min. Multimode ST-SC-LC PC 0,3 dB > 30 dB Multimode MT-RJ PC 0,3 dB NA Singlemode ST-SC-LC PC 0.3 dB > 40 dB Singlemode SC-LC APC 0,3 dB > 55 dB Singlemode MT-RJ NA NA NA Pigtails maxistrip: available products Fibre type Connector N-number SM SM APC ST N123.4MTY LANmark-OF Pigtail ST Singlemode Maxistrip LSZH 9/125 1m Yellow SC N123.4MCY LANmark-OF Pigtail SC Singlemode Maxistrip LSZH 9/125 1m Yellow LC N123.4MLY SC N120.4MDY LANmark-OF Pigtail SC SM APC Maxistrip LSZH 9/125 1m Yellow LC N120.4MPY LANmark-OF Pigtail LC SM APC Maxistrip LSZH 9/125 1m Yellow MTRJ OM1 N123.0MMO LANmark-OF Pigtail MTRJ OM1 Maxistrip LSZH 62.5/125 1m Orange ST N123.0MTO LANmark-OF Pigtail ST OM1 Maxistrip LSZH 62.5/125 1m Orange N123.0MCO LANmark-OF Pigtail SC OM1 Maxistrip LSZH 62.5/125 1m Orange LC N123.0MLO LANmark-OF Pigtail LC OM1 Maxistrip LSZH 62.5/125 1m Orange N123.5MMA LANmark-OF Pigtail MTRJ OM2/OM3 Maxistrip LSZH 50/125 1m Aqua ST N123.5MTA LANmark-OF Pigtail ST OM2/OM3 Maxistrip LSZH 50/125 1m Aqua SC N123.5MCA LANmark-OF Pigtail SC OM2/OM3 Maxistrip LSZH 50/125 1m Aqua LC N123.5MLA LANmark-OF Pigtail LC OM2/OM3 Maxistrip LSZH 50/125 1m Aqua MTRJ OM4 LANmark-OF Pigtail LC Singlemode Maxistrip LSZH 9/125 1m Yellow SC MTRJ OM3 Description N123.7MMA LANmark-OF Pigtail MTRJ OM4 Maxistrip LSZH 50/125 1m Aqua ST N120.7MTA LANmark-OF Pigtail ST OM4 Maxistrip LSZH 50/125 1m Aqua SC N120.7MCA LANmark-OF Pigtail SC OM4 Maxistrip LSZH 50/125 1m Aqua LC N120.7MLA LANmark-OF Pigtail LC OM4 Maxistrip LSZH 50/125 1m Aqua 03/12/10 - http://www.nexans.co.uk Page 223 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Pigtails Tight Buffer • • • • • Tight buffer pigtail for ease of splicing Insertion loss per connection: 0.3 dB maximum Factory terminated bre assembly 100 % factory tested Compatible with LANmark-OF splice cassette with heat shrink protection. Description Pigtail family characteristics • • • • • Fibre assembly to terminate cable with fusion splicing Available with ST, SC, LC and MTRJ connectors Suitable for use in patch panels using splice cassettes. The pigtails can be stripped in one action over a distance of 1-2 cm. Insertion loss: typical value is 0.1 dB, maximum value is 0.3 dB. Fibre types • Nexans LANmark-OF pigtails are available in all standardised optical bre classes, multimode and singlemode. • The MM50 version is designed to be used in a OM3 or a OM3xt compliant system and is backwards compliant with OM2 and OM2xt systems. The outher sheath for this type of pigtail is aqua. • The MM62.5 version is designed for use in OM1 or OM1xt compliant systems. These pigtails are orange. • The singlemode version is OS2 compliant with G652d bre inside. These pigtails are yellow. • The multimode versions can be used in laser optimised systems using the LANmark-OF xt cables. Standards International ISO/IEC 11801 Compatibility and installation practices • Tight buffer pigtails are compatible with heat shrink splice cassettes (N890.020) with heat shrink protections (N890.021). • Tight buffer pigtails are recommended to be used with tight buffer cables, i.e. with 900 um bres. When using loose tube cables (250 um bres) additional stress on the loose tube bres should be limited as much as possible • Around the splice area the pigtail needs to be stripped till the cladding before insertion in the splice tool. • For proper alignment in the fusion splice tool the pigtail is xed on the 900 um outer sheath. There is no need to strip the outer sheath of the pigtail on the place for xation for getting a proper xation. Guarantuees Nexans LANmark-OF pigtails are covered by Nexans warranty as described in the General Terms and Conditions 03/12/10 - http://www.nexans.co.uk Page 224 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Pigtails Tight Buffer Optical performance pigtails Fibre type Connector Polishing Insertion loss max. Return loss min. Multimode ST-SC-LC PC 0,3 dB > 30 dB Multimode MT-RJ PC 0,3 dB NA Singlemode ST-SC-LC PC 0.3 dB > 40 dB Singlemode SC-LC APC 0,3 dB > 55 dB Singlemode MT-RJ NA NA NA Pigtails tight buffer: available products Fibre type Connector N-number SM SM APC OM1 ST N123.4TTY LANmark-OF Pigtail ST SM Tight Buffer LSZH 9/125 1m Yellow SC N123.4TCY LANmark-OF Pigtail SC SM Tight Buffer LSZH 9/125 1m Yellow LC N123.4TLY SC N120.4TDY LANmark-OF Pigtail SC SM APC Tight Buffered LSZH 9/125 1m Yellow LC N120.4TPY LANmark-OF Pigtail LC SM APC Tight Buffered LSZH 9/125 1m Yellow MTRJ N123.0TMO LANmark-OF Pigtail MTRJ OM1 Tight Buffer LSZH 62.5/125 1m Orange ST N123.0TTO LANmark-OF Pigtail ST OM1 Tight Buffer LSZH 62.5/125 1m Orange N123.0TCO LANmark-OF Pigtail SC OM1 Tight Buffer LSZH 62.5/125 1m Orange LC N123.0TLO LANmark-OF Pigtail LC OM1 Tight Buffer LSZH 62.5/125 1m Orange N123.5TMA LANmark-OF Pigtail MTRJ OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua ST N123.5TTA LANmark-OF Pigtail ST OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua SC N123.5TCA LANmark-OF Pigtail SC OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua LC N123.5TLA LANmark-OF Pigtail LC OM2/OM3 Tight Buffer LSZH 50/125 1m Aqua MTRJ OM4 LANmark-OF Pigtail LC SM Tight Buffer LSZH 9/125 1m Yellow SC MTRJ OM3 Description N120.7TMA LANmark-OF Pigtail MTRJ OM4 Tight Buffer LSZH 50/125 1m Aqua ST N120.7TTA LANmark-OF Pigtail ST OM4 Tight Buffer LSZH 50/125 1m Aqua SC N120.7TCA LANmark-OF Pigtail SC OM4 Tight Buffer LSZH 50/125 1m Aqua LC N120.7TLA LANmark-OF Pigtail LC OM4 Tight Buffer LSZH 50/125 1m Aqua 03/12/10 - http://www.nexans.co.uk Page 225 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Adaptors 03/12/10 - http://www.nexans.co.uk Page 226 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Snap-In Adapter Description Application LANmark-OF Snap-In adapters have been designed for snapping into the modular OF patch panels and ZD boxes. They are available in single SC, dual SC, LC duplex and MT-RJ version. The 2 Small Form Factor connector types offer double density, as two bre connections are offered on the SC-type footprint. Installation time is saved as the snap-in concept replaces the timeconsuming screwing attachment of coupling devices. Performance LC and SC versions are available in Multimode and Singlemode, MT-RJ is only available in Multimode. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 227 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Snap-In Adapter Product List Nexans ref. N205.611 N205.621 N205.614 N205.624 N205.612 N205.613 N205.623 Name LANmark-OF Snap-In Adapter 2LC-2LC Multimode LANmark-OF Snap-In Adapter 2LC-2LC Singlemode LANmark-OF Snap-In Adapter DSC-DSC Multimode LANmark-OF Snap-In Adapter DSC-DSC Singlemode LANmark-OF Snap-In Adapter MT-RJ - MT-RJ LANmark-OF Snap-In Adapter SC-SC Multimode LANmark-OF Snap-In Adapter SC-SC Singlemode =Make to order, =Make to stock Connector type LC LC SC Duplex SC Duplex MT-RJ SC SC = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 228 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Standard Adaptors Description Standard format adaptors and couplers Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 229 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Standard Adaptors Product List Nexans ref. N205.127 N205.158 N205.135 N205.131 N205.133 N205.153 N205.123 =Make to order, =Make to stock Name Dual SC coupler MM Dual SC coupler SM LANmark-OF MTRJ adapter Multimode LANmark-OF Quad LC Multimode adaptor LANmark-OF Quad LC Singlemode adaptor LANmark-OF Singlemode adaptor ST-ST LANmark-OF adaptor Multimode ST-ST = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 230 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Tools & Accessories 03/12/10 - http://www.nexans.co.uk Page 231 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Cleaning Tools • Cleaning tools for cleaning bre connector and adaptors • Cleaning tools for single connectors:SC,ST and LC • Cleaning tools for male and female array connectors Description Cleaning op bre connectors and adaptors is extremely important to achieve optimal optical performance and low loss connectivity. The Nexans’ cleaning tools allow cleaning unmated connectors and can also clean connectors that are installed in a patch panel. The cassette MPO cleaner allows cleaning effectively unmated male MPO connectors. Product List Nexans ref. N890.122 N890.125 N890.120 N890.121 Name LANmark-OF LC Cleaning Tool LANmark-OF MPO Cassette Cleaning Tool LANmark-OF MPO Cleaning Tool LANmark-OF SC/ST Cleaning Tool Standards International ISO11801:2002/ = Make to order, = Make to stock A1:2008 03/12/10 - http://www.nexans.co.uk Page 232 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Fibre Accessories • • • • • • • OF-LANmark accessories to complete the whole system. OF splice trays SC & ST connectors SC & ST couplers Fusion splice protection & Tool Cable gland & splitter tube Micro tube Description Application • Optical bre accessories to complete all Nexans OF products, patch panels, ZD boxes, splitter box. • Designed for the installation of zone wiring, bre to the ofce, bre to the desk and backbone connections. Compatibility Suitable for tight buffer cable (direct termination) or loose tube using splice tray and pigtails Compatible with all Nexans ST or SC patch panels, zone distribution boxes and splice box Installation • The ST and SC connectors are in both versions hot melt or epoxy eld installable for easy installing. • The single ST and dual SC couplers are available in single mode and mono mode to complete all OF structural hardware. • The splice trays are easy to x in all Nexans OF patch panels, OF ZD boxes and can distribute 12 optical bres. • Cable glands can be useful for entering cables or distributing bres in to the OF patch panels and OF ZD boxes. • Aluminium fusion splice protection protect the spliced bres and are easily manageable in the splice tray. A • tool is offered for easy installing the aluminium fusion splice protection. • Splitter tube aloud to split up your cable into different patch panels. • A blind plate completes the e-ssential patch panel when used as splice patch panel. • Micro tubes of 0.9mm can be used to install a hot melt connector on a loose tube bre. 03/12/10 - http://www.nexans.co.uk Standards International ISO/IEC 11801 Page 233 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark-OF Fibre Accessories Product List Nexans ref. N890.043 N441.132 N890.147 N890.146 N890.045 =Make to order, =Make to stock Name Cable gland for splitter tube Essential-OF Blind face plate (For splitter) LANmark-OF Cable gland 20mm LANmark-OF Cable gland 25mm Microtube 0.9 mm = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 234 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Intelligent Infrastructure Management LANsense is Nexans Intelligent Infrastructure Management (IIM) solution. It is an internet enabled hardware and software package which can automatically discover and monitor network connectivity in real-time, to ensure network connections are secure and that connectivity documentation is always 100% accurate. LANsense is vendor independent and can be retro-tted to existing systems. Benets: • • • • • • Increased Security Cost effective change control and management Reduced downtime Asset Management Remote site monitoring the ability to integrate, control, and manage building management services (Access Control, intruder systems, CCTV, HVAC etc) Nexans work in partnership with iTRACS, the leaders in IIM software, and offer two levels of software: • LANsense Enterprise - the full featured version requiring specialist conguration • LANsense - a pre-congured solution but with limited options for customisation. These software solutions can be congured with different hardware products to deliver specialist solutions for Data Centres, Enterprise, or SME customers with branch networks. For more information on becoming a Nexans Certied LANsense Partner please contact us at [email protected] 03/12/10 - http://www.nexans.co.uk Page 235 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Software Choice of software functionality Description LANsense is Nexans Intelligent Infrastructure Management (IIM) solution. It is an internet enabled hardware and software package which can automatically discover and monitor network connectivity in real-time, to ensure network connections are secure and that connectivity documentation is always 100% accurate. LANsense is vendor independent and can be retro-tted to existing systems. Benets: • • • • • • Increased Security Cost effective change control and management Reduced downtime Asset Management Remote site monitoring the ability to integrate, control, and manage building management services (Access Control, intruder systems, CCTV, HVAC etc) Nexans work in partnership with iTRACS, the leaders in IIM software, and offer three levels of software: • LANsense • LANsense Enterprise Edition • LANsense Data Centre Edition Standards International ISO/IEC 11801 These software solutions can be congured with different hardware products to deliver specialist solutions for Data Centres, Enterprise, or SME customers with branch networks. 03/12/10 - http://www.nexans.co.uk Page 236 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense EMAC EMAC Products Description Corporate data centres are well known as signicant power users, with a large sized data centre consuming similar amounts of power to an average sized town. As data centres today generate more heat output and often suffer from inadequate cooling, the need to operate efciently and cost effectively against infrastructure and power constraints is increasing. Obviously the greater capacity required, the greater impact on ensuring continuity of supply. Add to this, the escalating cost of energy, and the requirement for management information and control becomes evermore critical. Nexans provides a range of standard intelligent power management capabilities, for both new and existing builds specied for both power monitoring only, or a combination of power monitoring with individual outlet control. Standards International Nexans specication Dened upper and lower thresholds allow the client to differentiate between warning and critical status, generating various alarms and alerts, with appropriate escalation paths. Aggregation of conguration information across data centre equipment, for intelligent monitoring and alarm processing, provides ‘real time’ identication of changes, scheduled polling and the ability to capture detailed data to produce highly sophisticated and graphical management information reports, enabling clients to perform trend analysis and risk management for mission critical services. Status information can be gathered either locally or remotely via secure authenticated IP access (LDAP) monitoring RMS volts, amps, kVA, kWh, power factor and frequency. Detailed values and management information across device location, power and cooling, network connectivity, asset application and customer information enable us to present analysis on current and historical trending. This trend analysis can be further utilised to help CIOs make informed decisions on capacity planning, risk analysis, performance benchmarking and policing service level agreements. To optimise both power consumption and energy use, our intelligent offerings make it possible to meter actual power usage and produce trend data for any single or group of physical systems, enabling: • • • • • • • Adequate capacity for existing & future needs Monitoring, measuring & reporting of power usage via multiple clients Billing stream capability for hosted clients Prevention of unauthorised use of power outlets / equipment deployment System load management (phase balancing, capacity planning etc) Recovery of locked servers via remote IP power cycling Alarming & trending of system, rack, powerstrip and outlet level overload conditions. RoHS conform Yes 03/12/10 - http://www.nexans.co.uk Page 237 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense EMAC Characteristics Usage characteristics RoHS conform Yes RoHS conform Yes 03/12/10 - http://www.nexans.co.uk Page 238 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense EMAC Product List Nexans ref. N878.21220 N878.32001 N878.32002 Nouveauté N878.41004 Nouveauté N878.41001 N878.41003 Nouveauté N878.NIPM Nouveauté N878.22110 N878.24210 N878.22210 N878.22215 N878.11002 Nouveauté N878.11003 Nouveauté N878.11004 Nouveauté N878.31001 N878.31002 Nouveauté =Make to order, =Make to stock Name LANsense Dual Supply Link Box 32A LANsense Humidity Sensor 2m LANsense Humidity Sensor RJ45 LANsense Magnetic Door Sensor RJ45 4m LANsense Microswitch Door Sensor 4m LANsense Microswitch Door Sensor RJ45 2m LANsense Non-Invasive Power Monitor LANsense PDU 32A 12x10A IEC C13 Horizontal LANsense PDU 32A 16x10A IEC C13 Monitor and Control LANsense PDU 32A 16x10A IEC C13 Vertical LANsense PDU 32A 24x10A IEC C13 Vertical LANsense Rack Manager II 6 Channel Autosensing LANsense Row Controller 12 Channel Autosensing LANsense Row Controller Expansion Module LANsense Temperature Sensor 2m LANsense Temperature Sensor RJ45 2m = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 239 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense Cu panel • LANsense IIM compatible • Empty for use with modular connectors sold separately Description LANsense copper patch panels carry on-board intelligence which remains dormant until enabled by LANsense analysers and software. The panels have inbuilt sensors to detect the connection status of each port and an I/O connector to link to the analysers. Manufactured from steel, the panel provides a robust, high density mounting mechanism for Nexans modular connectors. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 240 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense Cu panel Characteristics Usage characteristics I/O Connector - Panel Product List Nexans ref. N881.011 N881.051 Nouveauté 195513-1001 Remplacé N881.671 Nouveauté N881.681 Remplacé N881.685 Remplacé N881.675 Nouveauté N881.411 Nouveauté N881.311 Nouveauté N881.111 Remplacé N881.151 Remplacé N881.351 Nouveauté N881.251 Remplacé N881.255 Remplacé N881.451 Nouveauté N881.455 Nouveauté N881.061 Nouveauté Type 2 =Make to order, =Make to stock Name LANsense 24 Way Patch Panel for 808 connectors LANsense 24 Way Patch Panel for 808 connectors LANsense 24 Way Patch Panel for 808 connectors (ITT branded) LANsense Angled Panel 24 Snap-In Black LANsense Angled Panel 24 Snap-In GG45 Black LANsense Angled Panel 24 Snap-In GG45 White LANsense Angled Panel 24 Snap-In White LANsense Empty Sliding Patch Panel for 24 Snap-In connectors, Black LANsense Panel 24 Snap-In Black LANsense Panel 24 Snap-In GG45 Black LANsense Upgrade Frontplate for Fixed Modular Panel 24 GG45-type snap-in connectors, Black LANsense Upgrade Frontplate for Fixed Modular Panel 24 Snap-In connectors, Black LANsense Upgrade Frontplate for Sliding Modular Panel 24 GG45-type snap-in connectors, Black LANsense Upgrade Frontplate for Sliding Modular Panel 24 GG45-type snap-in connectors, White LANsense Upgrade Frontplate for Sliding Modular Panel 24 Snap-In connectors, Black LANsense Upgrade Frontplate for Sliding Modular Panel 24 Snap-In connectors, White LANsense Upgrade for 24 port 808 Modular Panel = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 241 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cu Patch Cords • • • • • 9th pin for port detection Ensures maximum channel performance Cat 5e & Cat 6 & Cat 6A/10G Screened & Unscreened Available in different lengths Description The Nexans LANsense patchcord range is suitable for use in voice or data network installations. The 4 pair construction and robust RJ45 connectors provide for long term network reliability. The patchcords have an unobtrusive external probe built into the plug boot which mates with the sensors built into the patch panels. The patchcords can be supplied in different lengths and with different colour latch protectors to allow differentiation of services and workgroups. Standards International EN 50265-2-1; ISO/ IEC 11801 National TIA/EIA-568-B.2 03/12/10 - http://www.nexans.co.uk Page 242 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cu Patch Cords Product List Nexans ref. LDWPCS010L0U10 LDWPCS020L0U10 LDWPCS030L0U10 LDWPCS050L0U10 LDWPCU010L0U10 LDWPCU020L0U10 LDWPCU030L0U10 LDWPCU050L0U10 LEWPCS010L0U10 LEWPCS020L0U10 LEWPCS030L0U10 LEWPCS050L0U10 195600-5010-3 195600-5020-3 195600-5030-3 195600-5050-3 N88A.P1F015OK Nouveauté N88A.P1F010OK Nouveauté N88A.P1F020OK Nouveauté N88A.P1F030OK Nouveauté N88A.P1F050OK Nouveauté =Make to order, =Make to stock Category Length (m) Screen Cat. 5e 1 FTP Cat. 5e 2 FTP Cat. 5e 3 FTP Cat. 5e 5 FTP Cat. 5e 1 UTP Cat. 5e 2 UTP Cat. 5e 3 UTP Cat. 5e 5 UTP Cat. 6 1 FTP Cat. 6 2 FTP Cat. 6 3 FTP Cat. 6 5 FTP Cat. 6 1 UTP Cat. 6 2 UTP Cat. 6 3 UTP Cat. 6 5 UTP Name LANsense 5e FTP PVC P/Cord 1m LANsense 5e FTP PVC P/Cord 2m LANsense 5e FTP PVC P/Cord 3m LANsense 5e FTP PVC P/Cord 5m LANsense 5e UTP PVC P/Cord 1m LANsense 5e UTP PVC P/Cord 2m LANsense 5e UTP PVC P/Cord 3m LANsense 5e UTP PVC P/Cord 5m LANsense 6 FTP PVC P/Cord 1m LANsense 6 FTP PVC P/Cord 2m LANsense 6 FTP PVC P/Cord 3m LANsense 6 FTP PVC P/Cord 5m LANsense 6 UTP PVC P/Cord 1m LANsense 6 UTP PVC P/Cord 2m LANsense 6 UTP PVC P/Cord 3m LANsense 6 UTP PVC P/Cord 5m LANsense Patch Cord Cat 6A LSZH Screened 1.5m Orange Cat. 6a 1.5 FTP LANsense Patch Cord Cat 6A LSZH Screened 1m Orange Cat. 6a 1 FTP LANsense Patch Cord Cat 6A LSZH Screened 2m Orange Cat. 6a 2 FTP LANsense Patch Cord Cat 6A LSZH Screened 3m Orange Cat. 6a 3 FTP LANsense Patch Cord Cat 6A LSZH Screened 5m Orange Cat. 6a 5 FTP = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 243 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre Panels • LANsense IIM compatible • 24, 48 or 96 bre in 1HU versions • Available for LC and SC connectors Description The LANsense range of patch panels provide a high density transition between building cables and active equipment. Very high density versions are available with up to 96 bre (48 ports) with LC for data centre environments. Standard 24 or 48 bre version with SC connections are also available. A variety of cable entry holes are located at the rear of the panels to allow a wide range of cable variants to be accommodated. Cable entry hole blanks and bre management are included with the panel. A complementary range of cable glands, that are supplied separately, ensure that cables are secured and enter the panel in a controlled manner. A simple to remove lid gives easy access to the panel interior. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 244 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre Panels Product List Nexans ref. N883.131 Jusqu'à épuisement du stock N883.221 Nouveauté N883.261 Nouveauté N883.133 Nouveauté N883.223 Nouveauté N883.233 Nouveauté N883.182 Nouveauté N883.181 Nouveauté N883.2B48LCMM Nouveauté N883.2B48LCSM Nouveauté =Make to order, =Make to stock Connector I/O Connector type Panel Name LANsense 24 SC Singlemode Patch Panel SC Type 1 LANsense 48 Fibre LC Multimode Patch Panel LC Type 2 LANsense 48 LC Multimode Patch Panel Black LC Type 2 LANsense 48 SC Singlemode Patch Panel SC Type 2 LANsense 96 LC Multimode Patch Panel LC Type 2 LANsense 96 LC Singlemode Patch Panel LC Type 2 LANsense Fibre Panel 24 SC Multimode Black SC Type 2 LANsense Fibre Panel 24 SC Singlemode Black SC Type 2 SC Type 1 SC Type 2 LANsense Pre-Loaded Patch Panel 48 LC Multimode Sliding Black LANsense Pre-Loaded Patch Panel 48 LC Singlemode Sliding Black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 245 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre patchcords • Additional copper pin for port detection • High bandwidth OM3 bre • Available with LC, MTRJ, or SC connectors Description The MTRJ, SC and LC LANSense patch cord uses the standard MTRJ, SC and LC duplex connector, enabling high-density ber connections to be achieved. The MTRJ, SC and LC LANSense cord however has an over-boot to incorporate the sensing capability of the LANSense products. The LANSense patch cords are available in both high bandwidth OM3 and single-mode OS2 bre types and so offer a comprehensive range of patch cords for interfacing with the latest network equipment. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 246 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Fibre patchcords Product List Nexans ref. N884.5LLP1 N884.5LLP2 N884.5LLP3 N884.5LLP5 N884.4LLY1 N884.4LLY2 N884.5MMP1 Jusqu'à épuisement du stock N884.5MMP2 Jusqu'à épuisement du stock N884.5MMP3 Jusqu'à épuisement du stock N884.5MMP5 Jusqu'à épuisement du stock N884.5CCP1 N884.5CCP2 N884.5CCP3 N884.5CCP5 N884.4CCY1 N884.4CCY2 N884.4CCY3 N884.4CCY5 =Make to order, =Make to stock Length (m) Connector type 1 LC 2 LC 3 LC 5 LC 1 LC 1 LC Name LC Duplex LANsense P/Cord 50/125 OM3 - 1m LC Duplex LANsense P/Cord 50/125 OM3 - 2m LC Duplex LANsense P/Cord 50/125 OM3 - 3m LC Duplex LANsense P/Cord 50/125 OM3 - 5m LC Duplex LANsense P/Cord 9/125 OS1 - 1m LC Duplex LANsense P/Cord 9/125 OS1 - 2m MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 1m 1 MT-RJ MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 2m 2 MT-RJ MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 3m 3 MT-RJ MT-RJ Duplex LANsense P/Cord 50/125 OM3 - 5m 5 MT-RJ SC Duplex LANsense P/Cord 50/125 OM3 - 1m SC Duplex LANsense P/Cord 50/125 OM3 - 2m SC Duplex LANsense P/Cord 50/125 OM3 - 3m SC Duplex LANsense P/Cord 50/125 OM3 - 5m SC Duplex LANsense P/Cord 9/125 OS2 - 1m SC Duplex LANsense P/Cord 9/125 OS2 - 2m SC Duplex LANsense P/Cord 9/125 OS2 - 3m SC Duplex LANsense P/Cord 9/125 OS2 - 5m 1 2 3 5 1 2 3 5 SC SC SC SC SC SC SC SC = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 247 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense Analysers • • • • 1U version up to 256 ports 6U version from 512 to 2048 ports Master and Link variants enabling upto 20480 ports per IP address Virtually unlimited scalability Description A LANsense analyser is required to monitor all network ports, record changes in the events log, and continuously update and maintain the connectivity database. It connects to the equipment presentation panel or integration strip and the horizontal distribution panel using I/O cables, and is in turn connected to the LANsense cable management SQL database. It should be noted that 2 analyser ports (one for the horizontal connection and one for the system connection) are required for each user channel to be monitored. Master and Link analysers can be connected to form a star wired network capable of monitoring up to 20480 ports in a "patch zone" using a single IP address. Multiple patch zones can be connected to a single database providing almost unlimited scalability. Standards International UL and CSA approval 03/12/10 - http://www.nexans.co.uk Page 248 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense Analysers Product List Nexans ref. LXWANLL0101 Remplacé LXWANLM0101 Remplacé LXWANLS0101 Remplacé 195560-0603 Remplacé 195560-0602 Remplacé 195560-0601 Remplacé N870.1UL Nouveauté N870.1UM Nouveauté N870.6UL Nouveauté N870.6UM Nouveauté =Make to order, =Make to stock I/O Connector - Analyser Name LANsense 1U Link Analyser Type A LANsense 1U Master Analyser Type A LANsense 1U Standalone Analyser Type A LANsense 6U Link Analyser Type A LANsense 6U Master Analyser Type A LANsense 6U Standalone Analyser Type A LANsense Analyser 1U Link - MarkII Type B LANsense Analyser 1U Master - MarkII Type B LANsense Analyser 6U Link - MarkII Type B LANsense Analyser 6U Master - MarkII Type B = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 249 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] NGA • Next Generation Analyser • Seperate analyser and display functions • Increased density • Supports additional functionality • Simplied and more exible system design Description The Next Generation Analyser is an exciting new development which opens up many possibilities for efcient analyser network design and advanced functionality to support the LANsense platform Key features • • • • • • • • • • • System Master Card (SMC) running Linux OS Self diagnostic test and health status No Cooling required Detects up to 8 connections on a single port 9th wire electrostatic protection Analyzer Card (AC) hot swap support Automated rmware distribution/installation Conguration by any Windows XP device Multiple deployment options Software control of Smart Patch Panel (SPP) interfaces “Plug and Play” deployment 03/12/10 - http://www.nexans.co.uk Standards International ISO/IEC 11801 Page 250 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] NGA Product List Nexans ref. N870.PSU2 Nouveauté N870.3UC Nouveauté N870.3UL Nouveauté N870.3UM Nouveauté N870.PSU7 Nouveauté N870.ACC Nouveauté N870.SPP Nouveauté N870.SMC Nouveauté N870.UPP Nouveauté =Make to order, =Make to stock Name LANsense NGA 2 Amp Power Supply Unit LANsense NGA 3U Card Cage LANsense NGA 3U Card Cage Link Cover LANsense NGA 3U Card Cage Master Cover LANsense NGA 7 Amp Power Supply Unit LANsense NGA Analyser Card LANsense NGA HMI Panel 1U LANsense NGA System Master Card LANsense NGA USB Interface Adaptor = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 251 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense I/O and Master/Link cables • I/O cables for analyser to panel connection • Master/Link for Master analyser to Link analyser connection Description LANsense accessory cables are divided into two sub families: Master / Link cables are used to interconnect Master and Link and analysers to form a star wired analyser network capable of monitoring a patch zone of up to 20480 ports. Multiple patch zones can exist within a LANsense database I/O cords are used to connect LANsense patch panels or integration strips to the analysers. The 12 way adaptor and 3 x 8 Way splitter are used to maximise the usage of analyser ports within an installation. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 252 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense I/O and Master/Link cables Product List Nexans ref. LXWCCL160XOO LXWCCL030XOO LXWCCL040XOO LXWCCL080XOO 196102-0019 LXWCCP021A20 196102-0028 LXWCCP030A20 196102-0040 LXWCCP043A20 N871.CIO0010 Nouveauté N871.CIO003 Nouveauté N871.CIO005 Nouveauté N871.NIOH0010 N871.NIOH0100 N871.NIOH0020 N871.NIOH0050 Name Analyser M/L Cord 16.0m Analyser M/L Cord 3.0m Analyser M/L Cord 4.0m Analyser M/L Cord 8.0m I/O Cord 24 way - 1.9m I/O Cord 24 way - 2.1m I/O Cord 24 way - 2.8m I/O Cord 24 way - 3.0m I/O Cord 24 way - 4.0m I/O Cord 24 way - 4.3m LANsense I/O Cable PVC Type C Rev 2 10m LANsense I/O Cable PVC Type C Rev 2 3m LANsense I/O Cable PVC Type C Rev 2 5m Mark II I/O Cable 24 way - 1.0m Mark II I/O Cable 24 way - 10.0m Mark II I/O Cable 24 way - 2.0m Mark II I/O Cable 24 way - 5.0m Mark II I/O Cable Adaptor 12 way N871.NIOHA2X12 150mm Mark II I/O Cable Splitter 3 x 8 way N871.NIOH0102 350mm I/O Connector Analyser N/A N/A N/A N/A Type A Type A Type A Type A Type A Type A =Make to order, I/O Connector Panel N/A N/A N/A N/A Type 2 Type 1 Type 2 Type 1 Type 2 Type 1 =Make to stock Mat length (m) 16 3 4 8 1.9 2.1 2.8 3 4 4.3 Type C Type 2 10 Type C Type 2 3 Type C Type 2 5 Type B Type B Type B Type B Type 2 Type 2 Type 2 Type 2 1 10 2 5 Type B N/A 0.2 Type B N/A 0.4 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 253 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANsense Integration Strips • LANsense IIM compatible • Integration Strips designed for specic equipment Description LANsense Integration Strips are used to provide LANsense port detection functionality on non LANsense enabled products like switches in an interconnect environment. They are used instead of a system side or port replication panel (used in a crossconnect environment) and allow LANsense cords to be connected directly into active equipment. Integration strips are usually provided to t 24 port devices but other port counts can be accomodated. In order to create an Integration Strip a template is used to accurately communicate the dimensions and port layout of the device. Standards International Nexans specication 03/12/10 - http://www.nexans.co.uk Page 254 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Industrial LAN & Harsh Environments 03/12/10 - http://www.nexans.co.uk Page 255 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry Copper cables Description Copper cables for LANs in industrial and exposed areas. Standards International ISO/IEC 11801; ISO/ IEC 24702 03/12/10 - http://www.nexans.co.uk Page 256 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry Copper cables Product List Nexans ref. N10i.002 N10i.004 Name LANmark Industry S/FTP AWG23 PUR black 500m reel LANmark Industry SF/UTP AWG24 LSZH+PE black 500m reel = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 257 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry Optical Fibre cables Description Fibre optic cables for LANs in industrial and exposed areas. Standards International ISO/IEC 11801; ISO/ IEC 24702 03/12/10 - http://www.nexans.co.uk Page 258 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry Optical Fibre cables Product List Nexans ref. N165.922 Name LANmark Industry TBX 6x multimode 50/125 OM3 PUR black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 259 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry DIN-Rail Outlets and boxes Description DIN-Rail mount Outlets and boxes for LANs in industrial and exposed areas. Standards International ISO/IEC 11801; ISO/ IEC 24702 03/12/10 - http://www.nexans.co.uk Page 260 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry IP65/67 outlets LANmark Industry IP67 outlets Description IP65/67 outlet for LANs in industrial and exposed areas. Standards International ISO/IEC 11801; ISO/ IEC 24702 03/12/10 - http://www.nexans.co.uk Page 261 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry IP65/67 outlets Product List Nexans ref. N42i.001 N42i.002 Name LANmark Industry IP65/67 outlet kit 2 Snap-In Category 6 black LANmark Industry IP65/67 outlet kit 2 Snap-In Category 6A black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 262 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry patch cord RJ45 IP67/IP20 Cat.6 Description Patchcords IP67/IP20 for LANs in industrial and exposed areas. Standards International ISO/IEC 11801; ISO/ IEC 24702 03/12/10 - http://www.nexans.co.uk Page 263 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Industry patch cord RJ45 IP67/IP20 Cat.6 Product List Nexans ref. N10i.E34DJ N10i.E34DJ N10i.E34OJ N10i.E34FJ N10i.E34HJ =Make to order, =Make to stock Name LANmark Industry patch cord RJ45 IP67 Single-end Category 6 screened PVC 10m Yellow LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 1.5m Yellow LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 10m Yellow LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 3m Yellow LANmark Industry patch cord RJ45 IP67/IP20 Category 6 screened PVC 5m Yellow = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 264 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] General Accessories & Cabinets Nexans have a complete range of accessories and hardware to complete the LAN system 03/12/10 - http://www.nexans.co.uk Page 265 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Datacenter racks and frames • • • • • 19-Inch mounting equipment for high-density cross-connect Ideal in Datacenters Designed to host both Copper and Fibre cabling Robust metal construction Enhanced access and cord management Description Standards Application LANmark High-Density racks and frames have been designed to host busy Cross-Connects in datacenters. Specic attention has been given to technical constraints of datacenters such as cooling and space scarcity. Numerous features contibute to an optimal space utilisation and enable installation on busy datacenter oors. These High-Density racks and frames enable excellent front, rear and lateral access. This is of great importance during installation but also during maintenance and upgrade operations. Proper management of large numbers of cords and securing clarity is critical for datacenters management and reliability over the life time. Examples of equipment that can be hosted in LANmark High-Density rack and frames are given below: • • • • • • • • International ISO/IEC 11801:2002/ A2:2008 Angled panels and accessories High Density Fibre optic panels MPO panels LANsense - Intelligent patching Suitable for Cat.6A, 7 and 7A Suitable for OM3, OM4 anD OS2 future Cat 6A and Class EA applications EMAC - Environmental control Performance LANmark High-Density racks and frames have been designed to host all LANmark bre optic and copper products. Installation Nexans LANmark-6 feature accessories and bracket enabling the installtion in various conguration and location of a datacenter. please see the datasheet of the main products for details. Guarantees Nexans LANmark High-Density Rack and Frames are covered by a parts and labour warranty as described in the Nexans Certied System Warranty. 03/12/10 - http://www.nexans.co.uk Page 266 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Datacenter racks and frames Product List Nexans ref. N345.000 Nouveauté N345.012 Nouveauté N345.400 Nouveauté Name LANmark High-Density Cross-Connect Cabinet 42U - Basic LANmark High-Density Cross-Connect Cabinet 42U - incl. Doors and Lateral Panels LANmark Overhead Patching Frame 4U = Make to order, = Make to stock Selling delivery information Delivery info: Datacenter racks and frames 03/12/10 - http://www.nexans.co.uk Page 267 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Patch Guides, Blank Panels & Cable Management • • • • Patch guides to manage and store all patch cords. 1 HU and 2 HU for high density. 1 HU with rings for easy access. Cable guide for all patch panels without clip-on. Description For a correctly managed installation, Nexans offers a full range of cable management accessories to complement our patch panel and cabinet range. The range is suitable for all Nexans Copper and Optical patch panels. The new offering is Nexans branded to blend with other Nexans products used in a cabinet. The cable management range is designed for all 19" cabinets. The range includes patch guides and cable guides. Patch Guides The Nexans patch guide range enables orderly patch cord storage. All the Nexans accessories are guaranteed to maintain the required bending radius for patch cords which in turn ensures superior data transmission for the installation. The paint nished metal accessories provide improved stability over plastic guides on the market. The 1HU and 2HU universal patch guides are delivered with a front plate. The 8 cm depth provides for the bending radius and enough storage space for the patch cords. Two openings designed at the rear face improve the storage and entry possibilities for patch cords. Standards International ISO/IEC 11801 An alternative 1 HU 5- ring metal patch guide is offered. This accessory similarly allows for orderly patch cord management in any installation. Cable Guide The Nexans cable guide offers fast and reliable cable retention and grounding. The clip-on system is a proprietary Nexans design and improves the exibility, solidity and the grounding of your installation. 03/12/10 - http://www.nexans.co.uk Page 268 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Patch Guides, Blank Panels & Cable Management Product List Nexans ref. N109.207 N109.207BK Nouveauté N102.105BK N102.105 N102.117BK N102.117 N102.127BK N102.127 N521.672 Nouveauté N521.673 Nouveauté N521.678 Nouveauté N424.512 N102.115BK =Make to order, Name 1HU Blank Panel 1HU Blank Panel, black =Make to stock Colour White RAL 9002 Black 1HU Patch Guide with rings, Black 1HU Patch Guide with rings, White 1HU Universal Patch Guide with front cover, Black 1HU Universal Patch Guide with front cover, White 2HU Universal Patch Guide, Black 2HU Universal Patch Guide, White Black White RAL 9002 Black White RAL 9002 Black White RAL 9002 Angled Blank Panel Black Black Angled Panel Cover Black Black Angled Pass-Through Black Black Cable management plate for Essential Rear Connect Panels N424.xxx Letterbox Patch Guide 1HU Black Black Black = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 269 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Zone Distribution Boxes • • • • For use as consolidation point. Compatible with all LANmark snap-in connectors. 6 or 12 numbered snap-in ports with shutters. Easy to install Description Designed for use as consolidation points, zone distribution boxes signicantly increase the exibility of desk locations in open ofce environments. They are particularly useful in ofces where frequent relocation of outlets in the work area is required. Nexans ZD boxes are easy to install on walls, under raised oors or in ceiling voids, due to their multiple mounting features. They are compatible with all LANmark snap-in connectors, which can be easily inserted by a simple "one-click" movement. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 270 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] LANmark Zone Distribution Boxes Characteristics Construction characteristics Material Usage characteristics Field of application Product List Nexans ref. N521.600 N521.606BK Nouveauté N521.606 Nouveauté Steel Fixed installations Name LANmark ZD box 12 Snap-In White Width (mm) 230 =Make to order, =Make to stock Colour Height (mm) Depth (mm) White RAL 9002 45 200 LANmark ZD box 6 Snap-In Black 120 Black 42 125 LANmark ZD box 6 Snap-In White 120 White RAL 9002 42 125 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 271 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinets - Quick Mount Cabinets and Enclosures • • • • • 19" cabinet and extension 42 HU 800X800 at pack : easy and quick installation exclusive automatic earthing system security complete range of accessories Description Features High Quality Cabinet for installation of Nexans Cabling Solutions Products. Extremely easy and fast to install and hence very cost effective, thanks to • • • • • • • • • • • • • Delivery in separate parts which can be handled by only one person Fast and exible mounting within a few minutes Open structure which allows a free accessibility from all sides Easy to add or remove products after the cabinet has been installed Automatic earthing IP 20 (can be upgraded to IP 30 by asdding an extra roof) Possibility to x on the roof one to 8 individual fan Easy to add extensions or to replace panels Front and rear frames which can be installed in 3 different positions Glass mixed front door Only one standard tool required No small loose parts Secure your installation : front and rear door with eurolock and inside opening system for side panels Standards International ISO/IEC 11801 Light weight cabinet. All parts are packed in 6 small boxes which are very easy to manoeuvre. Several accessories are available for enhanced functionality. Door in tinted safety glass. 03/12/10 - http://www.nexans.co.uk Page 272 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinets - Quick Mount Product List Nexans ref. N340.103 Nouveauté N340.003 Nouveauté Name Width (mm) Depth (mm) Approximate net weight (kg) EXTENSION FOR QUICK MOUNT III 42HU 800x800 800 800 145.0 QUICK MOUNT III 42 HU 800x800 800 800 145.0 = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 273 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinets - Wall Mountable Cabinets and Enclosures Wall Mountable • 3 parts 19" wallmount 18HU • Easy installation Description A range of wall mountable cabinets for locations where space is a premium. Includes standard 19" cabinets and empty enclosers suitable for copper or bre accessories. Features • • • • • • • • • • • • • Hinged 3 part design for easy access extremely accessible swing frame design. (140mm for back part) Top and Bottom cable entry equipped with brushes Same functionalities as full size cabinet : 19" mounting frame Cable xing plates on the rear panel for tie wrap Hole for up to 3 individual fans on top and bottom 60 Kg Load Included a 1/1 scale template paper for screw hole preparation before installation vertical metal patch guide system on the front for easier handling Ideal for locations where space is at the premium security with a lock on the door tinted safety glass mixed door dimensions : 18HUX500mmx650mm 03/12/10 - http://www.nexans.co.uk Standards International Manufacturer specication Page 274 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinets - Wall Mountable Product List Nexans ref. N102.118 Nouveauté Name Wall Mount Cabinet 18 HU Mixed Door New Concept = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 275 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinet Accessories Cabinet and Enclosure Accessories Range Complete Range : shelves, spare parts, fans, powerbar,... Description Standards Complete range of accessories for 19" cabinets and enclosures • • • • • International ISO/IEC 11801 Spare parts Shelf Powerbar Ventilator Fan ... 03/12/10 - http://www.nexans.co.uk Page 276 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Cabinet Accessories Product List Nexans ref. N108.109 Remplacé N108.109BK Nouveauté N203.167 N303.162 N303.163 ISCS71003WMP01 Remplacé N333.165 N343.206 N203.158 N333.207 N203.156 N203.165 N203.160 N203.160A N303.164 N101.001 N201.171 N203.171 N340.185 N343.209 N343.204 N343.208 N343.102 N343.201 N343.202 N343.213 N343.205 N343.203 =Make to order, =Make to stock Name 100 x Caged nut (M6) + screw (M6*12) 100 x Caged nut (M6) + screw (M6*12), black 19 inch SHELF FOR 12/18HU CABINET 19 inch shelf (36-42HU)(max. 70 kg, 2 xation points) 19" SHELF (MAX. 70 KG) WITH 4 FIX.POINTS 1U Blank Panel 4 x ADJUSTABLE FEET FOR QUICK-MOUNT 8xpatch ring CLOSET DOC.HOLDER DOOR HANDLE FOR REAR PANELS OF Quick Mount NEON LAMP FOR CABINETS Power Bar 19 inch 1 HU 6 UK outlet Power Bar 19 inch 1 HU 6 UTE outlet + autofuse Power Bar 19 inch 1 HU 6 schuko outlet + autofuse SLIDING SHELF 19 inch pull out 1/3 maximum load of 30 Kg Signal grounding key Ventilator fan (110 V) + Power cable Ventilator fan (230 V) + Power cable additional plinth for quick mount additional roof (IP 30) for quick mount base for quick mount II & III closing plate for quick mount II connection kit for quick mount II & III extension cabinet front door for quick mount II & III rear door for quick mount II rear door for quick mount II & III roof for quick mount II & III side panel for quick mount II & III = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 277 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Miscellaneous Accessories Description Nexans have a complete range of accessories and hardware to complete the LAN system such as multicoloured shutters. Standards International ISO/IEC 11801 03/12/10 - http://www.nexans.co.uk Page 278 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Miscellaneous Accessories Product List Nexans ref. N420.655 N421.701 N421.701R N421.701B N421.701G N421.701Y N421.701GR N421.701BK Nouveauté N420.050 Nouveauté N420.655BK Nouveauté N108.111 Nouveauté =Make to order, =Make to stock Name Blank Snap-In ller for unused port, white White shutter for Snap-In structural hardware Red shutter for Snap-In structural hardware Blue shutter for Snap-In structural hardware Green shutter for Snap-In structural hardware Yellow shutter for Snap-In structural hardware Grey Shutter for Snap-In Structural Hardware Black shutter for Snap-In structural hardware Dust cap for RJ45 Blank Snap-In ller for unused port, black Dzus quarter-turn fastener = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 279 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Software, Training, & Services Adding value to Local Area Networks is about much more than high quality products. Nexans provide a range of tools and services, either directly or in conjunction with business partners, to provide an unrivalled service & support package to meet the demands of both installers and end users alike. 03/12/10 - http://www.nexans.co.uk Page 280 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] System Warranty Programs A parts guarantee is one thing. But what happens when you put them together? Many companies may be specialised in one area but what happens if you have an infrastructure problem between buildings – who is responsible for deciding if it is the copper or bre campus link at fault. With a Nexans solution you don’t have to worry because we cover the complete cabling system, regardless of transmission medium or the building topology: • Copper, and Fibre • Horizontal, Backbone or Campus Nexans understands different cabling technologies and the building infrastructure, so that’s what we cover with the warranty. Description A company's communication system is crucial to its industrial and commercial success. Every single day, every company depends on the quality and distribution of information. With global experience, technological mastery in various building architecture, and a broad portfolio of products, Nexans matches the solution to your needs. Nexans empowers your local area networking infrastructure to do better and faster business. Offering Quality of Service to your users and customers is the reference for your success. Quality of Transmission, the performance of your infrastructure, becomes more important and critical. Our state-of-the-art solutions are your best guarantee for : • performance • reliability • value for money Standards International Manufacturer specication 03/12/10 - http://www.nexans.co.uk Page 281 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Network Design Tools Nexans Visio Templates (NVT) version 3.00 (NEW) is now available for download to enable users to create fast professional cabinet layout drawings and includes new enhanced features. NVT3 can be freely downloaded and includes now 6 intelligent product libraries (stencils) working under MS Visio to easily create professional Distributor layouts. Discover our Nexans Easy Design 1.0 software NED saves time,reduces design and BoM errors. NED is using a simple intuitive user interface to quickly collect the cabling project data and by using the shapes from the Nexans Visio Template library plus a new NED library it will provide the user with: • The Building conguration layouts • The Distributor rack congurations including data about horizontal distribution and cords • The full and complete Bill of Material of the cabling system Description Standards International Manufacturer specication 03/12/10 - http://www.nexans.co.uk Page 282 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Network Design Tools Product List Nexans ref. Toolkit NVT Name LAN Calculation Toolkit Nexans Visio Template 3.1 with NVT 3D = Make to order, 03/12/10 - http://www.nexans.co.uk = Make to stock Page 283 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact LAN Systems (Nexans Cabling Solutions) Phone: +44 (0)1256 486640 [email protected] Training Services Nexans Cabling Solutions has elaborated its training program. Training is given at the Competence Centres in Brussels or Basingstoke, or on demand at your premises or in one of our regional Training Centres. Description No matter what your level is, we'll nd the best training program meeting all of your needs. The LAN technology evolution requires a wide and varied range of skills. No two projects are the same and our partner's position is important in this business. The aim is to nd the synergy between your needs and our training program. In order to make this "level training" program possible, the training has been divided into different modules to address different topics aimed at different people. • • • • • Installers Project Managers Designers, Consultants and Architects Commercial Staff that would like to improve their sales techniques End Users Anybody involved in cabling that would like to improve his knowledge and skils in this domain Trainees can obtain a "Nexans Cabling Solutions Expert level certication" when they succeed in the 3-day Expert training. It is clear that a new VAR, Distributor, or Certied System Installer will be required to succeed in the Expert training. If the new partner has no experience it is recommended that he will rst attend the basic training. If the partner has previous experience, he can directly follow the Expert training. Standards International Manufacturer specication Training Modules Overview Commercial: Module 3: Nexans Copper Cabling Solutions Module 8: Nexans Optical Fibre Cabling Solutions Expert Knowledge: Module 1: Premises Cabling Standards Module 2: Parameter for Copper Cabling Module 4: Installation Rules and Guidelines Module 7: Optical Fibre Theory and Principles Module 12: Design Training: Project Study Module 14: Design Training: Project Engineering Module 16: Project Management Hands-on: Module 5: Installation Practice & Testing Class D-E Links Module 6: Installation Practice & Testing Class F Links Module 9: Fibre Installation Practice with Direct Termination Module 10: Fibre Installation Practice on Fusion Splicing Module 11: Testing Optical Fibre Links Module 13: Nexans Easy Design Visio Software 03/12/10 - http://www.nexans.co.uk Page 284 / 285 All drawings, designs, specications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. LANMARK-6A - OPTIMISE SHORT LINKS 10G 80% of Data Centres will implement 10G in the coming years. Exceeding Category 6A standards, LANmark-6A enables short link support avoiding space problems by overlength cables. Screened technology eliminates alien crosstalk ensuring easy installation and on-site testing. LANmark-6A: Zero Risk 10G w w w. n e x a n s . c o m / L A N s y s t e m s [email protected] G l o b a l e x p e rt i n c a b l e s a n d c a b l i n g s y s te m s 01/2011 © Nexans Cabling Solutions Global expert in cables and cabling systems Nexans Cabling Solutions - Alsembergsesteenweg 2, b3 - B-1501 Buizingen - Belgium Tel: +32 2 363 38 00 - Fax: +32 2 365 09 99 - www.nexans.com/LANsystems [email protected]
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement