225kVA Cut Sheet

Add to my manuals
4 Pages

advertisement

225kVA Cut Sheet | Manualzz

225 kVA

Features at-a-glance

Single/Parallel in one box for modular design

Parallel Circuits in each UPS for reliability

True Online, Double-Conversion Technology

Dual Input Design (Alternate Input for bypass)

Static Bypass Switch

- Thyristor + Contactor for highest reliability

LCD Touch screen Graphic Display

IGBT Inverter – Space Vector Modulation

Output Isolation Transformer

All Digital Signal Processor (DSP) software logic using 12 bit processor

Front Access for Installation and

Maintenance.

Bottom or Side Access for Power Cables.

Input Specifications

Voltage range: 480V +15% -15%

(Optional Cabinet for 208V, 600V)

Frequency range: 60Hz, +/- 5%

Power factor: >0.98

Input current THD: less than 6% at 100% load

Surge protection: Meets ANSI C62.41

Battery Specifications

Cabinets or Racks with DC Breaker

Battery type: Sealed Valve Regulated Lead-Acid

Recharge time: 10 x discharge time to 90% capacity

DC Link: 480VDC Nominal

Environmental Specifications

Ambient temperature: 0C to +40C

Relative humidity: 5%-95% Non-Condensing

Altitude: 0 to 9000 feet without derating

Audible noise: Less than 76 dBA at 1 meter

Battery Temperature

Compensation

Generator Compatible 1.1:1

Monitoring Options

- RemotEye II (SNMP/Web)

- Memory Card w/software

- Dry Contacts

Output Specifications: 225

kVA/180 kW (0.8PF)

Voltage: 480Y/277V Standard

(Optional 600/347V)

Voltage regulation: +/- 1%

Freq. regulation: +/- 0.05% (Free running)

Dynamic response: +/-2% at 100% step load

Voltage Distortion:

(recovery in less than 1 cycle)

Less than 2% for 100% linear load

Less than 5% for 100% non-linear load

Freq. sync range:

Freq. slew rate:

+/- 5% (user selectable)

1 – 10 Hz/second (user selectable)

Voltage adjustment: +/-5% (user selectable)

Overload capacity: 1000% for 1 cycle

150% for 1 minute

Crest Factor:

125% for 10 minutes

2.3 : 1

Safety

UL/CUL 1778 Listed

All cabinets provide for seismic zone 4 mounting

Options

Input/Output Transformer Cabinet

Maintenance Bypass Cabinet

RemotEye II Network Adapter

“Security Plus” Maintenance Agreement

T8MS3K22KK6XSN rev 1.2 29 September 2009

G8000MM 225 kVA UPS Specifications

Item: T8MS3K22KK6XSN

Input Voltage

Output Voltage

Volts

Volts

Input Voltage Range

Minimum

Maximum

Frequency

AC Input Current

Nominal Amps

Maximum Amps

(1)

Bypass Input

Nominal Amps

Volts

Volts

Hz

Amps

Amps

Volts

Amps

AC Output Current

Nominal Amps Amps

10 Minutes Max. Amps

225

225kVA/180kW

480

480/277

+15% to -15%

408

552

60

(> 0.98 PF)

237

254

480/277

271

(at 0.8 PF)

271

338

Item: T8MS3K22KK6XSN

DC Link

Nominal DC Voltage Volts

Float Voltage

End of Discharge

Charger

Efficiency

Efficiency

Volts

Volts

Amps

Full Load Heat Dissipation

BTU/Hr.

kW

%

(1) Maximum Amps equals full load current plus battery recharge current.

225

225kVA/180kW

480

545

400

29.3 (Max)

93.3

44,105

12.9

T8MS3K22KK6XSN rev 1.2 29 September 2009

G8000MM 225 kVA UPS Specifications

A A

B

C

B

C

T8MS3K22KK6XSN rev 1.2 29 September 2009

G8000MM 225 kVA UPS Specifications

T8MS3K22KK6XSN rev 1.2 29 September 2009