VXF Series 2 Port Solenoid Valve for Dust Collector

VXF Series 2 Port Solenoid Valve for Dust Collector
2 Port Solenoid Valve
For Dust Collector
Series VXF
2 port solenoid valve for dust collector
Series VXF
VX2
Working principle (VXFA)
In this L-shaped 2 port valve, the bag filter is cleaned by high speed air jet and shock
Fluid from the IN side goes through the
wave to materialize high speed response and control of instantaneous large flow rate. De-energized
supply orifice and fills the pressure action
VXZ
VXD
chamber. The main valve is kept closed
by the force pushing down the valve and
the reaction force of the valve spring.
The supply port to the pressure
action chamber is installed in the
body and the diaphragm free from
stress concentration has a long life
span.
VXP
Valve spring
Pressure action
chamber
The pressure action
chamber capacity is
reduced.
High speed main valve
opening & closing/min.
pulse 50 ms
VXE
Supply orifice
VXR
VXH
Right after energized
VXF
Armature
When power is supplied to the solenoid
valve, the armature begins to be retracted,
and the pilot orifice opens. The fluid filled
in the pressure action chamber flows
through the pilot orifice to the OUT side.
VX3
VXA
Pressure action chamber
VCH
The main valve made of polyacetal
is free from sticking and strong
against produced shock waves.
Model
2150
VXF
2160
VXFA
2280
Port size
34
1
11 2
Energized
VDW
Since the bleeding lowers the pressure inside
the pressure action chamber, the valve pressing-down force becomes weaker than the valve
pressing-up force and the valve is opened.
Cv
9.5
18
45
VQ
LVM
Pressure action chamber
VCA
VCB
Controller dedicated for operation
Series VXFC
2 port solenoid valve for
dust collector (VXF)
Blow tube Nozzle
Dedicated
controller
VCL
Clean air outlet
VCS
Bag filter
5
VCW
Dust exhaust port
0.01 0.99
Two-time hitting can be set to improve the sweeping effect by
the bag filter. Two-time hitting is available by turning ON the
DIP SW (one-time by turning OFF).
O
F
F
9
0
OUT1 OUT2 IN1 IN2
8
6
7
4
5
3
1
SW2
2
0 0 0
1
OFF
0 0
456
78
901
2
SW1
ON
SW8
O
F
F
Dust including
air inlet
23
The valve controller turns ON/OFF
many valves for the dust controller.
Power voltage: 100 VAC to 220 VAC
24 VDC, 12 VDC
Output points: 6 points, 10 points
Two-time hitting function
sec
0 299
sec
LED LED
11
12
OUT CAS
LED LED
13
14
IN POW
140
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED10
Connection of multiple circuit boards is possible
Number of output points can be increased (16/20/26/30 points)
by connecting boards.
ON
Wide ranging time setting
1A
ON-time (output to the valve): 0.01 to 0.99 sec.
OFF-time (adjournment to next output): 0 to 299 sec.
Interrupt operation function
Interrupting an operation from an external switch is possible
using input signals.
5
OFF
SV2
SV1
SV4
SV3
SV6
SV5
SV8
SV7
SV10
SV9
5
COM
AC1 AC2 FG
5
140
4 x ø4.5
169
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXF
How to Order
Solenoid type
Normally closed
VXF 2150
06
Air operated type
VXFA 2150
06
1 G
Option
Standard
S∗
With silencer
∗ Refer to the table (2) below for availability.
Nil
Table (2) Option/Silencer
Model Noise reduction Effective area
2504-002 19 dB or more
33.9 mm
2
Electrical option
Nil
Model — Port size
2150
2160
2280
06
10
14
S
L
Rc 3/4
Rc 1
Rc 1 1 2
Z
∗ Refer to the table (1) given below for availability.
Rated voltage
1
2
3
4
5
6
7
8
9
None
With surge voltage suppressor
With indicator light
With light/
surge voltage suppressor
Electrical entry
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC
12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
Other (Contact us for inquiry)
∗ Refer to the table (1) given
below for availability.
∗∗ Refer to page 173 for ordering coil only.
G
Grommet
C
Conduit
D
DIN terminal
T
Conduit terminal
∗ Refer to the table (1) given below for availability.
Caution
Table (1)
Rated Voltage-Electrical Entry-Electrical Option
Insulation type
Class B
Electrical entry
G
C
D, T
S
L, Z
—
Electrical option
S Note)
1 (100 V)
앬
앬
앬
앬
2 (200 V)
앬
앬
앬
앬
3 (110 V)
앬
앬
앬
앬
AC
4 (220 V)
앬
앬
앬
앬
—
7 (240 V)
앬
앬
앬
—
8 (48 V)
앬
앬
앬
5 (24 V)
앬
앬
앬
앬
DC
—
6 (12 V)
앬
앬
앬
Note) Surge voltage suppressor is attached in the middle of a lead wire.
Selection
When selecting the air operated type VXFA, select 2 port solenoid
valves (with orifice dia. of ø3 or more and effective area of 6 mm2 or
more) in order to maintain the pilot valve performance.
170
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Port Solenoid Valve for Dust Collector
Series VXF
Model/Valve Specifications
Port Orifice
dia.
size (mmø)
20
34
1
27
Solenoid type
40
11 2
Model
Min.
Flow
Max. operating pressure
operating
Ambient
Fluid
characteristics Withstand
differential (MPa)
pressure
pressure temperature temperature
Air
differential Solenoid
Air
(MPa)
(°C) Note 1)
(°C)
operated
2
(MPa)
valve
valve Effective area (mm )
AC 1.0
VXF2150
VXFA2150
1.0
0.03
170
2.0
–10
to 60
DC 0.7
AC 1.0
VXF2160
VXFA2160
0.03
VXF2280
VXFA2280
0.03
1.0
330
2.0
–10
to 60
1.0
810
2.0
–10
to 60
DC 0.7
AC 1.0
DC 0.7
Mass
(g)
AC 5to 60 VXF
2150 530
VXFA
DC 5to 40 2150 350
VXF
AC 5to 60 2160 580
VXFA
DC 5to 40 2160 400
VXF
AC 5to 60 2280 1500
VXFA
DC 5to 40 2280 1300
Note 1) Dew point shall be –10°C or less. No condensation allowed.
Model
VXF
2150
VXF
2160
VXF
2280
Power Frequency
(Hz)
source
AC
DC
AC
DC
AC
DC
50
60
—
50
60
—
50
60
—
VXD
VXZ
VXE
VXP
VXR
Solenoid Specifications
Air operated type
VX2
Apparent
power (VA)
Pilot exhaust
Power
Temperature
Voltage
noise (dB)
consumptions
rise (°C)
fluctuation
(W)
(Rated
Without With
(%)
Inrush Holding
(Holding)
voltage)
silencer silencer
45
Rated
20
11
4.5
value
35
104
83
±10
—
—
55
6
45
Rated
20
11
4.5
value
35
105
85
±10
—
—
55
6
60
Rated
40
18
7.5
value
50
108
85
±10
—
—
8
60
VXH
VXF
VX3
VXA
VCH
VDW
VQ
LVM
VCA
VCB
VCL
VCS
VCW
171
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXF
Model Selection (In the case of using as a bag filter)
Model selection
The deterrioration of VXF/VXFA properties due to the tube length from data B (response time/idle time) and data C (start-up speed), can be measured.
Refer to this data to set energization time. Use data A (flow rate characteristics) to calculate the flow rate for each loading time separately in relation to the
nozzle dia./qty., pressure, and tube. The data does not correspond to the actual bag filter operation. (In the data: “Without tube” and Tube length ø = VXF)
How to calculate
How to read the data
Pilot valve
(I.D. ø6, ø10)
How to calculate
Provide the pressure from the air resource to the air
tank. Close the stop valve, set the nozzle dia. and
qty., and then energize the solenoid valve as well as
the pilot valve of the air operation valve in accordance
with the prescription. (Change the tube length.)
Stop valve
Energization
time
Electric signal
Air tank inside pressure PA
Ultimate pressure
Air
tank
Nozzle
Amplifier
Data (B) Response Time/Idle Time
VXF2150/VXFA2150
Tank 20l
Pressure 0.7 MPa
MP
ø6 x 6 pcs.
PM: Raised up to 0.41 MPa
MP
ø6 x 10 pcs.
ø6 x 10 pcs.
Tube
2,000
mm
ø66 x 8 pcs.
pcs
ø6 x 6 pcs.
VXF2160
VXFA2160
Tank 41l
ø6 x 10 pcs.
Pressure 0.7 MPa
MP
PM: Raised up to 0.43 MPa
MP
VXF2280
VXFA2280
Tank 70l
Pressure
0.7 MPa
ø10 x 8 pcs.
500 mm
ø6 x 6 pcs.
Without tube
(VXF2150)
A=0.5 MPa
MP
PA=0.5
ø6 x 6 pcs.
Time T1, T2 (ms)
Flow rate Q (Nl)
VXF2150
VXFA2150
Air tank 20l
PA=0.7 MPa
ø6 x 6 pcs.
Air tank 41l
PA=0.7 MPa
ø6 x 8 pcs.
Start-up time
Idle time T1
Response time T2
Solenoid oscillograph
Data (A) Flow Characteristics
Air tank 20l
A=0.7 MPa
MP
PA=0.7
Nozzle inside pressure
PM x 0.9
I.D. x qty.
PM: Raised up
to 0.48 MPa
T2 (Response time)
Energization time T (ms)
T1 (Idle time)
VXF2160/VXFA2160
Air tank 70l
A=0.7 MPa
MP
PA=0.7
Air tank 41l
A=0.7 MPa
MP
PA=0.7
Tube length L (mm)
How to read the graph
ø6 x 10 pcs.
ø66 x 14 pcs.
pcs
The longer the tube length, the longer the response time and wasted time. If
longer than the length in the diagram, the valve might not open due to the tube
resistance.
ø6 x 12 pcs.
ø66 x 12 pcs.
pcs
500 mm
Data (C) Start-up Speed
2,000
mm
Without tube
(VXF2160)
ø6 x 10 pcs.
A=0.5 MPa
MP
PA=0.5
ø6 x 10 pcs.
Energization time T (ms)
VXF2280/VXFA2280
Air tank 70l
A=0.7 MPa
MP
PA=0.7
Air tank 70l
A=0.7 MPa
MP
PA=0.7
Air tank 70l
A=0.7 MPa
MP
PA=0.7
ø10 x 8 pcs.
Flow rate Q (Nl)
ø10 x 12 pcs.
ø10
10 x 12 pcs.
pcs
ø10 x 10 pcs.
ø10
10 x 8 pcs.
pcs
ø10
10 x 8 pcs.
pcs
ø10
10 x 10 pcs.
pcs
Inlet pressure: 0.7 MPa
MP
Start-up speed θ (MPa/ms)
Flow rate Q (Nl)
ø6 x 14 pcs.
Air tank 41l
PA=0.7 MPa
ø6 x 10 pcs.
Without tube
(VXF2280)
VXF(A)2150
Tank 20l
ø6 x 6 pcs.
VXF(A)2160
Tank 41l
10pcs.
pcs.
ø6 x 6
VXF(A)2280
Tank 70l
ø10 x 8 pcs.
100 mm
Tube length L (mm)
500 mm
A=0.5 MPa
MP
PA=0.5
ø10 x 8 pcs.
Energization time T (ms)
How to read the graph
Even if the energizing time is constant, a greater amount of air flows when the PA
is at 0.7 MPa than at 0.5 MPa. Moreover, the greater the air tank capacity, the
greater the amount of airflow. Furthermore, the greater the nozzle's total cross
sectional area, the greater the amount of airflow. While the flow volume changes
according to the length of the tube, be aware that a wasted flow volume is
involved during a return.
How to read the graph
The start-up speed stands for the degree of the nozzle
inside pressure rise per the unit of time. The greater it is,
the stronger the shock wave from the nozzle becomes.
It also means that the closing speed increases and
consumption of air can be used effectively.
Start-up speed θ = PM x 0.9
∆t
MPa/ms
172
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Port Solenoid Valve for Dust Collector
Series VXF
Construction
Solenoid type
Air operated type
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
VXF
VX3
VXA
Component Parts
No.
1
2
3
4
5
6
Description
Body
Bonnet
Diaphragm assembly
Spring
Hexagonal bolt
Operated valve for dust collector
VCH
Material
Aluminum
Aluminum
NBR, POM
Stainless steel
Stainless steel
——
VDW
VQ
LVM
VCA
Operated Valve for Dust Collector Part No.
VCB
VCL
VXF 2150 00 1 G
Model — Port size
2150
2160
2280
VCS
Electrical option
Rc 3/4
Rc 1
Rc 1 1/2
Nil
S
L
Z
VCW
None
With surge voltage suppressor
With indicator light
With light/surge voltage suppressor
Rated voltage
1
2
3
4
5
6
7
8
9
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC (50/60 Hz)
220 VAC (50/60 Hz)
24 VDC
12 VDC
240 VAC (50/60 Hz)
48 VAC (50/60 Hz)
Other
Electrical entry
G
C
D
T
Grommet (G, GS)
Conduit (C)
DIN terminal (D, DS, DL, DZ)
Conduit terminal (T, TS, TL, TZ)
173
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXF
Dimensions
VXF2165 0: Solenoid type
Grommet: G
2xM
VXF2280: Solenoid type
Grommet: G
2xM
Model
VXF2150
VXF2160
VXF2280
M
Port size
Rc
34
1
11 2
A
B
C
D
E
F
H
J
K
L
N
P
40
48
77
25
33.5
48.5
66
74
110
36
45
63
35.5
40
57
32.5
38
49
20
20
23
30
30
35
23
23
25
113
127
162
103
118
152
33
37
28
174
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 Port Solenoid Valve for Dust Collector
Conduit: C
Series VXF
Conduit
VXF2150/2160
VXF2280
K
39
39
41
Model
VXF2150
VXF2160
VXF2280
N
96
110
144.5
VX2
VXD
VXZ
VXE
VXP
VXR
VXH
DIN Terminal
DIN terminal: D
VXF2150/2160
VXF2280
Hexagon width across flats 22
Model
VXF2150
VXF2160
VXF2280
K
59
59
60
N
96
110
144.5
Q
45
45
48
Hexagon width across flats 22
Cable ø6 to ø12
Cable ø6 to ø12
VXF
VX3
VXA
VCH
VDW
VQ
LVM
VCA
VCB
VCL
VCS
Conduit terminal: T
VXF2150/2160
VCW
Conduit Terminal
VXF2280
Model
VXF2150
VXF2160
VXF2280
K
92
92
95
N
96
110
144.5
Q
59
59
62
175
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXF
Dimensions
VXFA2150/2160: Air operated type
Exhaust port
2xM
VXFA2280: Air operated type
Exhaust port
2xM
Model
VXFA2150
VXFA2160
VXFA2280
M
Port size
Rc
34
1
11 2
A
B
C
D
E
F
H
J
K
L
P
40
48
77
25
33.5
48.5
66
74
110
36
45
63
35.5
40
57
32.5
38
49
20
20
23
30
30
35
23
23
25
72
86
114
33
37
55
176
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VXF
2 Port Solenoid Valve for Dust Collector
Controller Specifications: Series VXFC
How to Order Controller
Specifications
Model
Input voltage
Output voltage
ON time
Time setting OFF time
Time accuracy
Number of output points
Operating ambient temperature
Operating ambient humidity
Ouput current
Power supply fuse
VXFC 06 D
Number of
output points
06
10
Voltage
D 24 to 48 VDC
D-6
12 VDC
A 85 to 220 VAC
6
10
VXFC 06
10 A
85 to 220 VAC
VXFC 06
10 D
24 to 48 VDC
Same as input voltage
0.01 to 0.99
0 to 299
±2%
6 to 10 points
0 to 50°C (No condensation)
45 to 80% (No condensation)
0.3 A or less
0.3 A or less
3A
1A
VXFC 06
10 D-6
12 VDC
VX2
VXD
VXZ
0.3 A or less
1A
VXE
VXP
Two-time Hitting Function
Interrupt operation Function
A two-time hitting function is adopted to improve the bag filter dusting
efficiency. Turn ON the dip switch for two-time hitting (OFF for one-time
hitting).
(Effective up to the number of setting channels)
Interrupting an operation from an external switch is possible using
input signals.
Operation sequence diagram
4 output points
Two-time hitting only for CH2
For
ON for 1 sec.
OFF for 2 sec.
2 sec.
1 sec.
OFF t
CH2
VXA
OFF t
OFF t
1 sec.
VDW
Dimensions
VQ
1 sec.
Power SW OFF (Output stop)
Controller
No.n
(Slave)
Slave
setting
901
Terminal block
for power supply
VCB
5
0 0 0
SW8
VCA
OUT1 OUT2 IN1 IN2
SW2
1
2
3
4
5
6
7
8
9
0
0 0
SW1
1
2
OFF
O
F
F
ON
0.01 to 0.99 sec
0 to 299 sec
LED LED LED LED
14
13
12
11
OUT CAS IN POW
VCL
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 LED9 LED10
Output display LED
SV2
SV1
SV4
SV3
SV6
SV5
SV8
SV7
SV10
SV9
COM
AC1 AC2 FG
13
9
5
OFF
9.5 9.5
4 x ø4.5
5
18.75
9.5
5
Output terminal block
Common terminal
block for output
1 cycle
No.1 output
VCW
30.5 13
52.5
14
No.2 output
9 9
47
140
No.3 output
VCS
Power switch
ON
1A
Operation sequence diagram
LVM
Terminal block for cascade connection
140
Controller
No.3
(Slave)
Slave
setting
Rotary SW for setting the
number of output points
23
VXFC10-1: One board allows outputs at merely 10 output points max.
But the points can be increased to 20 and 30 output points by
connecting cascades.
Controller
No.2
(Slave)
Slave
setting
Two-time hitting setting DIP SW
ON time setting SW
5
11.5
Cascade Connection
(Multiple-board connection)
Cascade setting DIP SW
OFF time setting SW
78
Power SW ON (Output start)
O
F
F
2 sec.
VCH
tA
tA
2 sec.
1 sec.
1 sec.
2 sec.
1 sec.
Two-time hitting
Controller
No.1
(Master)
Master
setting
VX3
ON t
CH1
CH4
1 sec.
2 sec.
2 sec.
1 sec.
Connection
Stop signal
VXH
VXF
456
2 sec.
Operation sequence diagram
CH3
ON time
Power supply
VXR
45.5
66.5
61
34 or less
26
Start
output
output
output
output
output
output
10 or less
Operation
38 or less
No.n output
(VXFC10)
177
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
VXF
Specific Product Precaution
Series
Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions,
and pages 17 to 19 for 2 Port Solenoid Valves for Fluid Control Precautions.
2 Port Solenoid Valve for
Dust Collector: Series VXF
Silencer
Caution
1. The silencer's response properties do not change in the initial
stage, but will change due to the blockage after long use. Replace it after using about 500,000 times. This number is subject
to change based on fluid quality and energization time.
2. When using a silencer, make space for silencer replacement.
Selection
Caution
1. The response performance and start-up speed deterriorate in
case of air operated type (VXFA) as compared with a solenoid
type (VXF) case. Refer to the data for pilot piping.
2. Note that for DC units, idle time and return time increase if the
voltage is lowered. If a surge voltage suppressor is installed,
the return speed decreases.
Dedicated Controller for
Operation: Series VXFC
Wiring
Warning
1. The controller starts its output the moment the power switch is
turned ON. Be aware that even if the power switch is turned
OFF, power is connected to the terminal board.
Caution
1. Make sure that the voltage of the power to be input matches
the voltage in the controller's specifications. The voltage of the
power that has been input becomes the voltage that is output
to the solenoid valves.
2. Connect a ground that is rated Class 3 or greater to the power
supply terminal board.
3. If the power source is DC, use caution to its polarity. If the polarity is incorrect, it may result in a malfunction or damage.
4. Refer to the separate operation manual for further details.
Environment
Caution
1. Operate under conditions that are free of vibration and impact.
2. Operate in an ambient temperature range between 0°C and
50°C.
3. Operate in an ambient humidity range between 45% to 85%
(with no condensation). For further details, refer to the instruction manual in which it is explained separately.
178
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com