YSI ProDSS
Water Quality Meters
YSI ProDSS Multiparameter Sampling Instrument
The YSI ProDSS (Professional Digital Sampling System) is designed for use in applications such as surface water,
groundwater, coastal waters, and aquaculture. The rugged and reliable ProDSS allows for measurement of up to
17 parameters. The ProDSS features user-replaceable digital smart sensors that are automatically recognized by
the instrument when connected. A backlit color display, large memory, convenient calibration procedures,
rechargeable battery, and powerful PC data management program (KorDSS) make the ProDSS user friendly.
The optional GPS function, wide range of sensors, and varying cable lengths allow for complete customization
of the ProDSS. Mil-spec (military spec) connectors and a waterproof (IP-67), rubber over-molded case ensures
durability to provide years of sampling even in the harshest field conditions.
FEATURES
PARAMETERS
• Single cable design features universal ports which
can accept any 4 sensors plus depth
• Long-life rechargeable lithium-ion battery
to power handheld and sensors
• Color display and backlit keypad allow for sampling
in all lighting conditions
• Digital smart sensors are automatically recognized
by the instrument and store calibration data
• User-replaceable cables and sensors provide
versatility, reduce down time and reduce overall
cost of ownership
• Large memory (> 100,000 data sets) with extensive
site list and Data ID tag capabilities
• KorDSS, a powerful data management software with
geo-mapping capability, is included with the instrument
• USB On-The-Go connector for PC connection,
recharging/powering the ProDSS and connecting
directly to a USB stick
• Global Positioning System (GPS) (optional)
• Cable lengths up to 100 meters available with or
without a depth sensor
• Rugged, waterproof case (IP-67 rated) with rubber
over-mold and metal, military-spec (MS) cable
connectors as well as rugged titanium sensors
• Multiple languages in handheld and KorDSS: English,
Spanish, Portuguese, French, German, Italian, Japanese,
Norwegian, and Chinese (simplified and traditional)
• Warranty: 3-year instrument; 2-year cable assembly
and sensors; 1-year pH and pH/ORP sensor modules;
6-months ammonium, nitrate and chloride sensor
modules.
Dissolved Oxygen (Optical)
Turbidity
pH
ORP/Redox
Conductivity
Specific Conductance
Salinity
Total Dissolved Solids (TDS)
Resistivity
Seawater Density
Total Suspended Solids (TSS)
Depth
Ammonium
Ammonia
Chloride
Nitrate
Temperature
CALL GEOTECH TODAY (800) 833-7958
ysi_prodss.qxp 10/31/14
Geotech Environmental Equipment, Inc.
2650 East 40th Avenue • Denver, Colorado 80205
(303) 320-4764 • (800) 833-7958 • FAX (303) 322-7242
email: [email protected] website: www.geotechenv.com
YSI ProDSS Specifications
GENERAL SPECIFICATIONS
Size
Weight with Batteries
Power
Instrument Operating Temperature
Instrument Storage Temperature
Display
USB Port
Cables
Sensor Ports
Warranty
Memory
Logging Modes
GLP Compliance
Languages
Certifications
GPS
Sites and Data ID
8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in. x 8.5 in. x 2.21 in.)
567 grams (1.25 lbs.)
Rechargeable lithium-ion battery pack providing ~48 hours of battery life (instrument only with backlight off)
0 to 50°C (32 to 122°F)
0 to 45°C (32 to 113°F) with battery installed; 0 to 60°C (32 to 140°F) without battery installed
Color, LCD graphic display
Built-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick
Available with or without depth sensor in 1, 4, 10, 20, 30, 40, 50, 60, 70, 80, 90, and 100-meters
4 universal sensor ports on each cable; can accept any ProDSS sensor
3-year instrument; 2-year bulkhead, cable assembly, and sensors; 1-year pH and pH/ORP sensor modules, ODO sensor caps, and Li-ion battery pack; 6-months ammonium, nitrate, and chloride sensor modules
> 100,000 data sets
Single point or continuous with autostable feature
Yes; 400 detailed GLP records can be stored and are available to view, download, and print.
English, Spanish, Portuguese, French, German, Italian, Japanese, Norwegian, Simplified Chinese, Traditional Chinese
CE; RoHS; IP-67; WEEE; FCC; UN Part III, Section 38.3, Test methods for lithium-ion batteries (Class 9)
Optional internal GPS; coordinates are stored with measurement data and site lists
100 user-defined sites and 100 user-defined data ID tags
INSTRUMENT, SENSOR AND CABLE
Sensor⁄Parameter
Temperature
pH
ORP
Dissolved Oxygen
Range
-5 to 70°C (temperature compensation range
for DO mg/L measurement: -5 to 50°C)
0 to 14 pH units
-1999 to 1999 mV
0 to 500%, 0 to 50 mg/L
Barometer
Conductivity
375 to 825 mmHg
0 to 200 mS/cm
Specific Conductance*
0 to 200 mS/cm
Salinity*
Total Dissolved Solids
(TDS)*
Resistivity*
Seawater Density*
Turbidity
0 to 70 ppt
0 to 100 g/L
Total Suspended Solids
(TSS)*
Ammonium**
Ammonia*
Chloride**
Nitrate**
Depth
0 to 2 Mohms
0.0 to 50.0 sigma, sigma T
0 to 4000 FNU
0 to 30000 mg/L
0 to 200 mg/L NH4-N
0 to 200 mg/L NH3 -N
0 to 18000 mg/L Cl
0 to 200 mg/L NO3 -N
0 to 328 feet (0 to 100 m)
Accuracy
±0.2°C
Resolution
0.1°C or 0.1°F (user selectable)
Units
°C, °F, K
±0.2 pH units
±20 mV
0 to 200%: ±1% of reading or 1% saturation, whichever is greater
200 to 500%: ±8% of reading
0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater
20 to 50 mg/L: ±8% of reading
±1.5 mmHg from 0 to 50°C
0-100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever is greater
100 - 200 mS/cm: ±1.0% of reading
0-100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever is greater
100-200 mS/cm: ±1.0% of reading.
User selectable reference temperature (15 to 25°C; default 25°C)
and compensation coefficient (0 to 4%/°C; default 1.91%)
±1.0% of reading or ±0.1 ppt, whichever is greater
Calculated from specific conductance and a user-selectable TDS
multiplier (0.30 to 1.00; default 0.65)
±0.1% Full Scale
–
0 to 999 FNU: 0.3 FNU or ±2% of reading, whichever is greater
1000 to 4000 FNU: ±5% of reading
User correlated from turbidity field measurements and lab TSS
measurements from grab samples
±10% of reading or 2 mg/L, whichever is greater
±15% of reading or 5 mg/L, whichever is greater
±10% of reading or 2 mg/L, whichever is greater
±0.013 ft. (±0.004 m) for 1, 4, and 10 m cable
±0.13 ft. (±0.04 m) for cables 20 m and longer
0.01 pH units
0.1 mV
0.01 mg/L and 0.1%, or
0.1 mg/L and 1% (user selectable)
pH, pH mV
mV
% saturation, % saturation local, mg/L, ppm
0.1 mmHg
0.001, 0.01 or 0.1 μS/cm
(range dependent)
0.001, 0.01, 0.1 mS/cm
mmHg, inHg, mbar, psi, kPa, atm
μS/cm, mS/cm
0.01 ppt
0.001, 0.01, 0.1 g/L
ppt or PSU
mg/L, g/L, kg/L
0.001, 0.01, 0.1 ohms
0.1 sigma or sigma T
0.1 FNU
ohm-cm, kohm-cm, Mohm-cm
Sigma, Sigma T
FNU, NTU
0.01, 0.1 mg/L
mg/L
0.01 mg/L
0.01 mg/L
0.01 mg/L
0.01 mg/L
0.001 m or 0.01 ft.
NH4-N mg/L, NH4-N mV
NH3-N mg/L
Cl mg/L, Cl mV
NO3-N mg/L, NO3 -N mV
m, ft.
μS/cm or mS/cm
*Derived/calculated parameter **ISEs for freshwater only; 20 meter maximum depth
Sensor⁄Parameter
Temperature
pH
ORP
Dissolved Oxygen
Barometer
Conductivity
Specific Conductance*
Salinity*
Total Dissolved Solids
(TDS)*
Resistivity*
Seawater Density*
Sensor Type⁄Measurement Method
Thermistor, installed on conductivity sensor
Combination glass bulb electrode, Ag/AgCl reference electrode with gelled electrolyte
Platinum button with Ag/AgCl reference
Optical luminescence - lifetime method
–
Four nickel electrode cell
Calculated from conductivity and temperature
Calculated from conductivity and temperature
Calculated from specific conductance and a user
selectable TDS multiplier (0.30 to 1.00; default 0.65)
Calculated from conductivity and temperature
Sigma is calculated from salinity, temperature, and pressure (depth)
Sigma T is calculated from salinity and temperature
Turbidity
Nephelometric - Optical, 90° scatter
Total Suspended Solids
User correlated from turbidity field measurements
(TSS)*
and lab TSS measurements from grab samples
Ammonium**
Ion selective electrode
Ammonia*
Calculated from ammonium, temperature, salinity, and pH
Chloride**
Ion selective electrode
Nitrate**
Ion selective electrode
Depth
Pressure transducer
*Derived/calculated parameter **ISEs for freshwater only ; 20 meter maximum depth
Calibration
Not available
1, 2, or 3 point
1 point
1 or 2 point
1 point
1 point
1 point
1 point
–
Maximum Depth
100 m
100 m
100 m
100 m
–
100 m
–
–
–
Warranty
2 years for conductivity/temperature sensor
2 years for pH and pH/ORP sensors, 1 year for pH and pH/ORP sensor modules
2 years for pH/ORP sensor 1 year for pH/ORP sensor module
2 years for optical DO sensor, 1 year for optical DO sensor cap
3 years, integrated into ProDSS handheld
2 years for conductivity/temperature sensor
–
–
–
–
–
–
–
–
–
1, 2, or 3 point
–
–
–
2 years for turbidity sensor
–
1, 2, or 3 point
–
1, 2, or 3 point
1, 2, or 3 point
1 point
20 m
–
20 m
20 m
–
2 years for ammonium sensor, 6 months for ammonium sensor module
–
2 years for chloride sensor, 6 months for chloride sensor module
2 years for nitrate sensor, 6 months for nitrate sensor module
2 years, integrated into cable assembly
Water Quality Meters
YSI ProDSS Multiparameter Sampling Instrument
ORDER SELECTION GUIDE
STEP 1 – SELECT INSTRUMENT
All instruments include a rechargeable lithium-ion battery (pre-installed), hand strap, USB
cable for charging the ProDSS battery and for connection to a PC, universal AC charger,
cable for connection to a USB memory stick, ProDSS quick start guide, and USB memory
stick containing KorDSS software and digital copy of the comprehensive manual.
Handheld with no GPS
Handheld with GPS
YSI Part No.
Geotech Part No.
626870-1
626870-2
72103410
72103411
STEP 2 – SELECT CABLE
Cables do not include an integrated temperature sensor. All cables include 4 universal
sensor ports and a maintenance kit (3 port plugs, tube of Krytox® lubricant, brush for
conductivity probe, syringe for depth sensor, and sensor installation/removal tool). A 1 lb.
weight is included with all cables 10 meters and longer while 10, 20, and 30 meter cables
include a cable management kit.
No Depth Sensor Cables
YSI Part No.
Geotech Part No.
1m
4m
10 m
20 m
30 m
40 m
50 m
60 m
70 m
80 m
90 m
100 m
626909-1
626909-4
626909-10
626909-20
626909-30
626909-40
626909-50
626909-60
626909-70
626909-80
626909-90
626909-100
12103517
12103518
12103519
12103520
12103521
12103522
12103523
12103524
12103525
12103526
12103527
12103528
Cables With Depth Sensor
YSI Part No.
Geotech Part No.
1m
4m
10 m
20 m
30 m
40 m
50 m
60 m
70 m
80 m
90 m
100 m
626910-1
626910-4
626910-10
626911-20
626911-30
626911-40
626911-50
626911-60
626911-70
626911-80
626911-90
626911-100
12103529
12103530
12103531
12103532
12103533
12103534
12103535
12103536
12103537
12103538
12103539
12103540
ProDSS attached to Tripod and
Flow Cell for groundwater applications
Titanium smart sensors can easily
be replaced in the field
STEP 3 – SELECT SMART SENSOR(S)
For highest accuracy, always install a conductivity/temperature sensor to compensate all
measurement data for temperature and dissolved oxygen data for conductivity.
Smart Sensor
YSI Part No.
Geotech Part No.
Optical Dissolved Oxygen (ODO):
Conductivity and Temperature:
Turbidity:
pH Sensor with module:
pH⁄ORP Sensor with module:
Ammonium Sensor with module:
Nitrate Sensor with module:
Chloride Sensor with module:
626900
626902
626901
626903
626904
626906
626905
626907
12103541
12103542
12103543
12103544
12103545
12103546
12103547
12103548
4-Port Bulkhead with four
user replaceable sensors
Water Quality Meters
YSI ProDSS Multiparameter Sampling Instrument
ORDER SELECTION GUIDE CONTINUED
STEP 4 – SELECT STANDARDS
STEP 5 – SELECT ACCESSORIES
YSI Part No.
Conductivity Standard,
1413US (pint):
Conductivity Standard,
8974US (pint):
4.01 pH Buffer
(pint):
7.00 pH Buffer
(pint):
10.00 pH Buffer
(pint):
Buffer Pack (4 one pint bottles)
pH 4, pH 7, pH 10, 1413US:
ORP Buffer
(250 mL):
DO, 0%, Solution
(pint):
Zobell Standard for ORP (mV)
calibration, 125 mL:
Turbidity Standard,
0 FNU (1 gallon):
Turbidity Standard,
12.4 FNU (1 gallon):
Turbidity Standard,
124 FNU (1 gallon):
Turbidity Standard,
1010 FNU (1 gallon):
Confidence Solution®:
To verify pH, ORP and
conductivity data
(not for calibration)
1 mg⁄L Ammonium Standard
(500 mL):
10 mg⁄L Ammonium Standard
(500 mL):
100 mg⁄L Ammonium Standard
(500 mL):
1 mg⁄L Nitrate Standard
(500 mL):
10 mg⁄L Nitrate Standard
(500 mL):
100 mg⁄L Nitrate Standard
(500 mL):
Geotech Part No.
–
12101014
–
12101029
–
12101017
–
12101018
–
12101019
–
12101063
–
12105020
–
12105017
061320
12103009
608000
12103085
607200
12103053
607300
12103089
607400
005580
12103227
12103045
003841
12103472
003842
12103473
003843
12103474
003885
12103475
003886
12103476
003887
12103477
Large, Hard-sided Carrying Case:
Large, Soft-sided Carrying Case:
Small, Hard-sided Carrying Case:
(1 and 4 meter)
Flow Cell:
Flow Cell Mounting Spike:
Tripod:
Ultra Clamp:
Shoulder Strap:
Belt Clip:
USB Car Charger:
Small External Battery Pack:
Will typically recharge battery
to ~50% when completely
discharged
Large External Battery Pack:
Will typically recharge battery
and charge second battery
to ~20%
AC Charger (USA):
Includes power supply and
USB cable (626991)*
AC Charger (International):
Includes power supply, USB
cable and outlet adapters*
Replacement Li-ion Battery Pack:
ProDSS USB Flash Drive*:
USB Cable for charging and
PC connection*:
Cable for connection to USB stick*:
Cable Maintenance Kit**:
Probe Guard Kit**:
Calibration⁄Storage Cup**:
Cable Management Kit***:
1 lb. Weight***:
4.9 oz. Weight:
YSI Part No.
626946
603075
626945
Geotech Part No.
12103559
12103459
12103556
599080
603056
063507
063517
603070
603069
626942
626943
12103554
12103456
12103463
12103462
12103471
12103461
12103558
–
626944
–
626940
12103560
626941
12103561
626846
626969
12103562
–
626991
626992
626990
626919
599786
603062
626918
605978
–
–
12103565
12103563
12103564
12103467
12103557
12103468
* Included with new ProDSS. Only one (1) AC charger is included based on region
** Included with all cable
*** Included with all 10, 20, and 30 meter cables
**** Included with all cables 10 meters and longer
CALL GEOTECH TODAY (800) 833-7958
Geotech Environmental Equipment, Inc.
2650 East 40th Avenue • Denver, Colorado 80205
(303) 320-4764 • (800) 833-7958 • FAX (303) 322-7242
email: [email protected] website: www.geotechenv.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement