Type: Project/Location: Contractor: RGS-TB Series Prepared By: Decorative 6, 12 and 24 V T-Bar Unit Model No.: Fully recessed units for T-Bar mounting in suspended ceilings. TYPICAL SPECIFICATIONS The RGS-TB Series battery units are designed for T-bar ceiling grid installation. This slim-line, unobtrusive unit is ideally suited for any commercial location where there is limited wall space and where the greater directional flexibility of ceiling-mounted heads is needed to provide greater light distribution. Supply and install a complete emergency lighting system as described herein and shown on the drawings. The Lumacell® Smart Diagnostic Micro controller board shall supply the rated load for a minimum of a 30 minutes to 87.5% of the rated battery voltage. The unit shall be rated 120V or 347V, 60 Hz and be CSA listed. The unit shall have an output of V. The charger shall be fully computer tested and its charge voltage factory set to ± 1% tolerance. Chargers with field-adjusted potentiometers are not acceptable. A pulse-type charger shall be employed to promote long battery life and reduce the potential for grid corrosion. The charger shall provide a continuous high charge to recharge the battery, when the battery is at full capacity, the charger will shut-off. Periodically the charger shall provide a pulse of energy to keep the battery topped off. The charger shall be current limited, temperature compensated, short-circuit proof and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit, which will connect the battery when the AC circuit is activated, and an electronic brownout circuit, which will activate the emergency lights when utility power dips below 75% of nominal voltage. A low voltage battery protection circuit shall be provided and will disconnect the battery from the fused output circuit at the end of discharge. The unit shall selftest for 1 minute every 30 days, 10 minutes on the 6th month and 30 minutes every 12 months. The unit shall be capable of full recharge in compliance with CSA specifications. The unit shall be furnished with sealed dust tight relay, a test switch and seven diagnostic LED indicator lights to continuously monitor the status of the unit: Battery Failure, Battery Disconnected, Charger Failure, Lamp Failure, Service Alarm, AC “ON”, Charger High Rate. The unit shall be T-bar mounted and come complete with tool-less emergency lighting heads requiring no tools to adjust or aim. The unit shall be Lumacell® model: . FEATURES •Rugged steel cabinet with corrosion-resistant undercoating. •Battery and charger are concealed above the ceiling level in the unit cabinet •Removable panel provides easy access to battery and circuitry •Test switch and LED indicators are mounted on the visible bottom panel •Units mount quickly and easily in standard 2’ x 2’ or 2’ x 4’ grids without any additional hardware •Solid-state pulse-type charger – current-limited, temperature- compensated, short-circuit proof and reverse-polarity protected •Unit comes standard with electronic lockout and brownout circuits •Sealed dust-proof transfer relay, test switch and LED indicator lights •Long-life, maintenance-free lead acid battery •Emergency lighting heads requiring no tools to adjust or aim. •Standard 120/347VAC input voltage •NEXUS® compatible (for more information on NEXUS®, please consult your sales representative) •CSA C22.2 No. 141 certified CABINET REPLACEMENT LAMPS DIMENSIONS B C D E F ORDERING CODE LAMP TYPE VOLTAGE/WATTAGE 23 3/4” Large Cabinet (60.3 cm) 7 1/4” (18.4 cm) 7 1/8” (18.1 cm) 10 5/8” (27.0 cm) 5 5/8” (14.3cm) 13” (33.0 cm) 570.0016-L Mini tungsten (9W) 6V-9W 23 3/4” (60.3 cm) 7 1/4” (18.4 cm) 4 5/8” (11.7 cm) 10 5/8” (27.0 cm) 3 1/4” (8.3 cm) 13” (33.0 cm) 570.0025-L Mini tungsten (9W) 12V-9W 570.0045-L Mini tungsten (9W) 24V-9W 580.0104-L MR16, LED 12V-5W DIMENSIONS 580.0093-L MR16, LED 12V-4W Dimensions are approximate and subject to change. 580.0097-L MR16, LED 6V-4W 580.0098-L MR16, LED 24V-4W 580.0100-L MR16, LED 24V-6W 580.0106-L MR16, LED 12V-6W Small Cabinet A a e For the complete list, please see the lamp chart on page 144-146. b d c 104 Date: www.lumacell.com f Type: Project/Location: Contractor: RGS-TB Series Prepared By: Date: Decorative 6, 12 and 24 V T-Bar Unit Model No.: RGS SERIES POWER CONSUMPTION AND UNIT RATING MODEL WATTAGE CAPACITY AC SPECS 1H30 2H00 RG36TB 0.10/0.04A 36 21 15 12 6 RG72TB 0.22/0.08A 72 42 30 24 12 RG108TB 0.22/0.08A 108 63 45 36 18 RG180TB 0.22/0.08A 180 105 75 60 30 RG12S36TB 0.09/0.03A 36 21 15 12 6 0.15/0.06A 72 42 30 24 12 RG12S100TB 0.34/0.12A 100 58 42 33 17 RG12S144TB 0.40/0.14A 144 84 60 48 24 RG12S200TB 0.41/0.14A 200 117 83 67 33 RG24S144TB 0.55/0.20A 144 84 60 48 24 RG24S288TB 0.67/0.23A 288 168 120 96 48 RG12S72TB 120/347VAC 30MIN 1H00 4H00 ORDERING INFORMATION SERIES RGS= 6V CAPACITY HOUSING 36= 36W 72= 72W 108= 108W 180= 180W RG12S= 12V 36= 36W 72= 72W 100= 100W 144= 144W 200= 200W RG24S= 24V 144= 144W 288= 288W TB= T-Bar # OF HEADS Blank= no heads 1= one head 2= two heads 3= three heads HEAD STYLE LAMP WATTAGE COLOUR AC VOLTAGE LD1= MR16 LED, 6V-4W Blank= factory white LD7= MR16 LED, 12V-4W BK= black LD9= MR16 LED, 12V-5W LD10= MR16 LED, 12V-6W LD13= MR16 LED, 24V-4W LD14= MR16 LED, 24V-6W 130LD1= deco head, MR16 LED, 6V-4W* 130LD7= deco head, MR16 LED, 12V-4W* 130LD9= deco head, MR16 LED, 12V-5W* 130LD10= deco head, MR16 LED, 12V-6W* 130LD13= deco head, MR16 LED, 24V-4W* MQM6W= MR16 mini-halogen, 6V-6W MQM10W= MR16 mini-halogen, 6V-10W MQM12W= MR16 mini-halogen, 12V-12W MQM20W= MR16 mini-halogen, 12V-20W 13020W= deco head, MR16 halogen, 12, 24V-20W* 13035W= deco head, MR16 halogen, 12, 24V-35W* 13050W= deco head, MR16 halogen, 12, 24V-50W* 13012W= deco head, MR16 halogen, 24V-12W* LH9W= large tungsten, 6V, 12V, 24V-9W, wedge base LH18W= large tungsten, 12V, 24V-18W, wedge base LH25W= large tungsten, 6V, 12V, 24V-25W, DCB MT9W= mini-tungsten, 6V, 12V, 24V-9W, wedge base MT18W= mini-tungsten, 12V, 24V-18W, wedge base MQ8W= mini-halogen, 6V, 12V-8W, quartz bi-pin MQ12W= mini-halogen, 6V, 12V, 24V-12W, quartz bi-pin LHQ8W= large halogen, 6V, 12V- 8W, bi-pin LHQ12W= halogen, 6V, 12V-12W, quartz bi-pin LHQ20W= large halogen, 6V, 12V, 24V-20W, bi-pin LHQ55W= large halogen, 12V-55W, H3 LHQ70W= large halogen, 24V-70W, H3 SB8W= large tungsten, 6V, 12V-8W, sealed beam SB18W= large tungsten, 6V, 12V-18W, sealed beam SB25W= large tungsten, 6V, 12V-25W, sealed beam QSB8W= large halogen, 6V, 12V-8W, sealed beam QSB12W= large halogen, 6V, 12V-12W, sealed beam QSB20W= large halogen, 6V-20W, sealed beam Blank= 120/347 VAC input ZC= 277VAC input * Polar white or black cabinets only. OPTIONS AT= auto-test* ATN= auto-test (non-audible)* NEX= NEXUS® system interface* NEXRF= wireless NEXUS® system interface* V= voltmeter A= ammeter CT= cab-tire DPF6= 6 cct. fuse panel LD= lamp disconnect LTS= light activated test switch RR2= remote test receiver** TD= time delay (programmable) TL= twistlock plug*** TMBB= AC/DC terminal block TMBD= DC terminal block TMBK= AC terminal block *Minimum lamp load required: 20% of unit capacity. * Not all options are available with NEXUS® system. Please consult your sales representative ** HH2= remote test transmitter (sold separately) *** 1 20V is standard EXAMPLE: RGS36TBILD1 www.lumacell.com 105
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement