Owner Instructions
Original Instructions
Warning! Read instructions before using the machine www.numatic.com
Operating Instructions
WV 570
WVD 570
WV 750
WV 750T
WVD 750
WVD 750T
WV 900
WVD 900
WVD 1800-DH
WVD 1800-PH
WVD 1800-AP
WVD
1800DH
WVD 1800DH WVD 1800PH WVD 1800AP
2
WV 570 WV 900
WVD 570 WVD 900
X 4
X 4
WV 900 / WVD 900
3
3
1
Vac
WVD 1800PH
WVD 1800AP
WD 570
WVD 570
WV 900
WVD 900
WVD 1800DH
WVD 1800PH
WVD 1800AP
4
Vac
4
2
1 2
WV 570 / WVD 570
1 2 3
WV 900 / WVD 900
1 2
WV 750T / WVD 750T
5
WVD 1800DH
1 2
3
4
6
WVD 1800PH
2
3
1
5
4
Pump
2
1 4
Vac
5
Pump
3
WVD 1800AP
WVD 1800DH / WVD 1800PH / WVD 1800AP
1 3
2
7
8
WV 570
WVD 570
WV 900
WVD 900
2
1
3
WV 570 / WVD 570
NVM - 3BH
WV 900 / WVD 900
NVM - 4BH
1
3
5
7
2
4
6
8
9
WV570
WVD 570
WV 570
WVD 570
Motor
1200W
2400W
Capacity
Dry
23 Ltrs
23 Ltrs
Data
WV / WVD 570
AirFlo Suction
38 L/sec
76 L/sec
Capacity
Wet
15 Ltrs
15 Ltrs
2400 mm w.g.
2400 mm w.g.
Size
415x415x645
Cleaning
Range
26.8m
26.8m
Weight
13.6 Kgs
15.8 Kgs
Class
II
Sound Pressure
73.6-79 dB
(IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
WV750
WVD 750
WVD 750 T
WV750
WVD 750
WVD 750 T
WV900
WVD 900
WV 900
WVD 900
WV 1800DH
WVD 1800DH
WV 1800PH
WVD 1800PH
WV 1800AP
WVD 1800AP
10
WV / WVD 1800DH
WV / WVD 1800PH
WV / WVD 1800AP
Motor
1200W
2400W
1200W
Capacity
Dry
35 Ltrs
35 Ltrs
35 Ltrs
Motor
1200W
2400W
Capacity
Dry
40 Ltrs
40 Ltrs
AirFlo
WV / WVD 750 (T)
Suction
38 L/sec
76 L/sec
38 L/sec
Capacity
Wet
25 Ltrs
25 Ltrs
25 Ltrs
2400 mm w.g.
2400 mm w.g.
2400 mm w.g
Size
680x550x940
Cleaning
Range
26.8m
26.8m
26.8m
Weight
21.4 Kgs
WV / WVD 900
AirFlo Suction
38 L/sec
76 L/sec
Capacity
Wet
32 Ltrs
32 Ltrs
2400 mm w.g.
2400 mm w.g.
Size
800x490x880
Cleaning
Range
26.8m
26.8m
Weight
22.5 Kgs
25.0 Kgs
Class
II
II
II
Sound Pressure
77.5-76.9 dB
(IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
Class
II
II
Sound Pressure
73.6-79 dB
(IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
Motor
WV / WVD 1800 DH / PH / AP
AirFlo Suction
1200W
2400W
1200W
2400W
1200W
2400W
38 L/sec
76 L/sec
38 L/sec
76 L/sec
38 L/sec
76 L/sec
2400 mm w.g.
2400 mm w.g.
2400 mm w.g.
2400 mm w.g.
2400 mm w.g.
2400 mm w.g.
Cleaning
Range
26.8m
26.8m
26.8m
26.8m
26.8m
26.8m
PH / AP
Pump Motor
----
50W
500W
Capacity
Wet
70 Ltrs
70 Ltrs
70 Ltrs
Size
684x785x935
Weight
31.2 Kgs
32.2 Kgs
35.0 Kgs
Class
I
I
II
II
I
I
Sound Pressure
73-77 dB
(IEC 60704-2-1)
Uncertainty: 0.2 dB (A)
About the machine
Company name and address
Machine Description
Voltage / Frequency
Power Rating
Weight (Ready to use)
Splash Proof Rating
Class 2 Symbol
WEEE Logo
CE Mark
Yr / Wk / Serial Number
Safety Critical Components
Mains lead
HO5VV-F x 10m x 2 x 1.00mm
2
HO5VV-F x 10m x 3 x 1.50mm
2
Filter Bag
NVM-3 BH >pp< construction 99.6%@0.3µm
NVM-4 BH >pp< construction 99.6%@0.3µm
Filter
Permatex NVM 604116 >pp< construction 96.0%@0.3µm
WEEE Legislation
(Waste, Electrical and Electronic Equipment)
Vacuum cleaner, accessories and packaging should be sorted for environmental-friendly recycling.
Only for EU countries:
Do not dispose of Vacuum cleaner into household waste!
According to the European Directive 2002/96/EC on waste electrical and electronic equipment and its incorporation into national law.
Vacuum cleaners that are no longer suitable for use must be separately collected and sent for recovery in an environmental-friendly manner.
PPE
Personal protective equipment that may be required for certain operations.
Ear Protection
Hi Viz Jacket
Safety Footwear Head Protection Safety Gloves Dust / Allergens Protection Eye Protection Protective Clothing
NOTE:
A risk assessment should be conducted to determine which PPE should be worn.
Caution Floorsign 11
Information for Wet & Dry Use Vacuum Cleaners
12
•
•
•
•
•
•
•
•
•
•
WARNING
Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of these machines.
As with all electrical equipment, care and attention must be exercised at all times during use, in addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe operation.
Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.
The machine shall be disconnected from the mains by removing the plug from the supply socket during cleaning or maintenance and when replacing parts or converting the machine to another function.
The machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction.
Children being supervised are NOT to play with the machine.
This appliance is intended to be assembled, cleaned and maintained by an adult.
This machine is not a toy.
Only use the socket outlet on the machine for purposes specified in the instructions.
CAUTION!
If foam/liquid comes out of machine exhaust, switch off immediately. Allow the accumulated liquid to drain out through the machine exhaust, check the float assembly to ensure correct operation, empty the container if full of liquid, reassemble the machine. Immediately upon start up there will be a certain amount of liquid issuing from the machine exhaust which will be the residue of liquid still within the power head. This will be quickly discharged after which the machine should function normally.
Liquid ejected from the machine could be hazardous as a result of its temperature, pressure or chemical content.
This machine is not suitable for the collection of biological hazards, hazardous or explosive dust. You should contact your local distributor if you require a machine capable of performing these tasks.
Ensure that the filtration system fitted to the machine is suitable for the material being collected.
This machine is for indoor use only.
This machine shall be stored indoors only
This product complies with the requirements IEC 60335 -2.69.
When moving from one place to another, consider the weight of the machine.
NOTE: This machine is also suitable for commercial use, for example in hotels, schools, hospitals, factories,
•
•
•
• shops and offices for other than normal housekeeping purposes.
DO
Use a bag and filter at all times when using ‘dry’.
Keep your machine clean.
Keep filters clean.
Regularly clean the water level limiting float safety valve and examine
for signs of damage or correct operation.
•
•
Keep hoses and tubes clear.
Replace any worn or damaged parts immediately.
• Regularly examine the power cord, if damage is found, power cord
must be replaced by a qualified person using the correct Numatic original part.
Empty dust container frequently.
Keep diffuser filter (where fitted) clean.
•
•
DON’T
•
•
•
Use steam cleaners or pressure washers to clean the machine
or use the machine in the rain.
Immerse in water for cleaning.
Allow any inexperienced repairs. Call the experts.
Use wet if float valve is not functioning or fitted.
Use to suck up hot ashes, or lighted cigarette ends.
Suck up liquid before emptying dirt from container.
Suck up dirt before emptying liquid from container.
Run the machine over the power cable during operation as a hazard may occur.
Pull on the cable to unplug the machine from the power supply.
Walk over-wet carpets, upholstery or fabrics.
Walk on clean carpets until fully dry.
Spray onto people or animals.
Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply outlet.
This machine can be used for wet and dry pick up.
Dry Mode maintenance / fault finding
If the vacuum cleaner stops working switch off and remove the plug from the wall before investigating were the fault lies.
If the vacuum cleaner will not pick up any debris from the surface, switch off and remove the plug from the wall, inspect the floor tool, wands and hose for blockages, if no blockages are found, the dust bag may be full if the dust bag is not full the filter may be blocked.
Wet mode / fault finding
If the vacuum cleaner stops working switch off and remove the plug from the wall before investigating were the fault lies.
If the vacuum cleaner has a blockage and will not pick up liquid, switch off and remove the plug from the wall, has the float valve operated, this will shut off the suction and the pitch of the vacuum motor will change Remove the power head and empty the liquid out of the container, if the container is empty, check that the floor tool wands and hose are not blocked.
After use always inspect the machine for damage.
13
OF
CONFORMITY
We hereby declare under our sole responsibility that the following equipment fulfi ls all the relevant provisions of the following EU Directives:
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
RoHS Directive 2011/65/EU
Machine Description:
Type: CVC, WV, WX series
Vacuum Cleaner
Manufactured by: Numatic International Limited
Relevant standards upon which conformity is declared include:
IEC60335-1:1991+A1+A2
IEC60335-2-2:1993+A1+A2
IEC60335-2-69:1997+A1
EN 55014-1 2001 +A1 2001, +A2 2002
EN 55014-2 1997 + A1 2001 (Cat II)
EN 50366 2003 + A1 2006
A technical construction fi le for this equipment is retained at the manufacturer’s address under the authorisation of the following signatory:
Name:Allyn Boyes Position: Technical Manager
Signed: Date: 01 /01/2013
Numatic International Limited,
Chard , Somerset.
TA20 2GB www.numatic.co.uk
GB
13
14
14” Simplex AP/PH 240V / 120V
WD-0244 (A03)
14” Duplex PTO 240V
WD-0246 (A02)
15
16
14” WVD Duplex 230V
WD-0255 (A02)
14” WV Simplex 240V / 120V
WD-0245 (A03)
17
18
14” WV Simplex AP/PH 220V
17/03/05 WD-0288 (A01)
14” WV Simplex 220V
WD-0289 (A01)
19
20
14” WV Duplex AP/PH 220V
WD-0290 04/03/09 (A02)
14” WV Duplex 220V
WD-0293 05/03/09 (A02)
21
22
23
598435
598146
598441
598142
598143
598941
598328
598257
598062
598140
598417
598284
598180
598235
598217
598841
598105
Heads
WV.570-2 - EUROPEAN HEAD
WV.570-2 - UK HEAD
WV.570-2 - (110 VOLT)
WV.570-2 - SWISS
WVD.570-2 - EUROPEAN HEAD
WVD.570-2 - UK HEAD
WVD.570-2 - (110 VOLT)
WV.900-2 - EUROPEAN HEAD
WV.900-2 - UK HEAD
WV.900-2 - (110 VOLT)
WVD.900-2 - EUROPEAN HEAD
WVD.900-2 - UK HEAD
WVD.900-2 (110 VOLT)
WVD.900-2 - SOUTH AFRICA
WVD.1800DH-2 - EUROPEAN HEAD
WVD.1800DH-2 - UK HEAD
WV.1800PH - UK HEAD
598000 WVD.1800PH-2 - UK HEAD
598153 WVD.1800AP-2 - EUROPEAN HEAD
598269 WVD.1800AP-2 - UK HEAD
Filters/ Baskets/Floats
604145
WV 1800 SERIES
TRASH BASKET
604116 PRIMARY PERMATEX FILTER
502034 WV570 FLOAT ASSEMBLY
500609 18 INCH FLOAT ASSEMBLY
389120
AP Type - Pump
110V/60HZ.(1800 DRUM)
389121 230V/50HZ.(1800 DRUM)
389123 220V/60HZ.(1800 DRUM)
389126 110V/50HZ.(1800 DRUM)
500976
500720
500385
500721
500722
500723
500913
236031
236009
236013
236017
236021
236029
236010
236014
236018
236022
236030
236011
236015
236019
236023
604245
Drums
WV 900 (C/W LOWER HANDLE)
WV/WVD1800 PLUS DRAIN HOSE
WV570 + CASTORS
1800 BLUE PUMP OUT (SMALL PUMP) (230V/50HZ)
1800 BLUE PUMP OUT (SMALL PUMP) (120V/60HZ)
1800 BLUE PUMP OUT(SMALL PUMP) (120V/50HZ)
1800 BLUE PUMP OUT (LESS PUMP / HOSE)
Cables
1MM X 3 CORE (SOCKET + PLUG) UK
1MM X 3 CORE (SOCKET + PLUG) EURO
1MM X 3 CORE (SOCKET + PLUG) SWISS
1MM X 3 CORE (SOCKET + PLUG) SOUTH AFRICA
1MM X 3 CORE (SOCKET + PLUG) AUSTRALIAN
1.5MM X 3 CORE (SOCKET + PLUG) UK
1.5MM X 3 CORE (SOCKET + PLUG) EURO
1.5MM X 3 CORE (SOCKET + PLUG) SWISS
1.5MM X 3 CORE (SOCKET + PLUG)
SOUTH AFRICA
1.5MM X 3 CORE (SOCKET + 16AMP PLUG)
AUSTRALIAN
X 1MM X 2 CORE (SOCKET + PLUG) UK
X 1MM X 2 CORE (SOCKET + PLUG) EURO
X 1MM X 2 CORE (SOCKET + PLUG) SWISS
X 1MM X 2 CORE (SOCKET + PLUG)
SOUTH AFRICA
X 1MM X 2 CORE (SOCKET + PLUG) AUSTRALIAN
Hose
10M DISCHARGE HOSE FOR AP MACHINES
24
Numatic International Limited, Chard, Somerset, TA20 2GB, ENGLAND.
Telephone 01460 68600 Fax: 01460 68458 www. numatic.co.uk