DATA SHEET
CROSS TECHNOLOGIES, INC.
REV. A
9/29/08
2017-36 Up/Downconverter, 950-1525 MHz Up, 2.0-2.5 GHz Down
The 2017-36 RF Up/Downconverter converts 2.0-2.5 GHz to 70 MHz (Down) and 70 MHz to 950-1525 MHz (Up) in 1 MHz steps with
low group delay and flat frequency response. Synthesized local oscillators (LO) provide frequency selection. Multi-function push button
switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm for
up and downconverters (red), remote operation (yellow), and Upconverter mute (yellow). Gain is manually controlled over a –10 to +30
dB range for the upconverter and over a 0 to +50 dB range for the downconverter as adjusted by the front panel multi-function pushbutton switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain settings
appear on the LCD display. Connectors are BNC female for IF and the optional external reference input and output, and BNC female
for RF. A high stability (±0.01ppm) option is also available. It is powered by a100-240 ±10% VAC power supply and housed in a 1.75”
X 19“ X 16” 1RU chassis.
MODEL 2017
DOWNCONVERTER
UPCONVERTER
U F=2225
D F=1450
G=+10
G=+25
UP/DOWNCONVERTER
MENU
CROSS TECHNOLOGIES INC.
EXECUTE
ALARM
REMOTE POWER
MUTE
ALARM
Front Panel
EQUIPMENT SPECIFICATIONS*
----------UPCONVERTER---------Input Characteristics (IF)
Impedance/Return Loss 75 /18 dB
Frequency
70 ± 18 MHz
Level
-40 to -10 dBm
Output Characteristics (RF)
Impedance/Return Loss 50/12 dB
Frequency
950 to 1525 MHz
Level
-20 to 0 dBm
1dB compression
+5 dBm
Channel Characteristics
Gain range (adjustable) -10 to +30 dB
Frequency Sense
Non-inverting
Frequency Response
±1.5 dB, 950-1525 MHz; ±0.5 dB, 36 MHz BW
---------DOWNCONVERTER--------Input Characteristics (RF)
Impedance/Return Loss 50 /12 dB
Frequency
2.0 to 2.5 GHz
Noise Figure, max.
15 dB (max gain)
Level
-70 to -20 dBm
1dB compression
-15 dBm at min. gain
Output Characteristics (IF)
Impedance/Return Loss 75/18 dB
Frequency
70 ± 18 MHz
Level/Max Linear
-20 dBm / -10 dBm
1dB compression
-5 dBm
Channel Characteristics
Gain range (adjustable) 0 to +50 dB
Image Rejection
> 50 dB, min
Freq. Sense (selectable) Inverting or Non-inverting
Frequency Response
±1.5 dB, 2.0-2.5 GHz
±0.5 dB, 36 MHz BW
--------UP and DOWNCONVERTER-------Channel Characteristics
Spurious Response
<-50 dBC
Group Delay, max
0.01 ns/MHz2 parabolic; 0.03 ns/MHz linear; 1 ns ripple
Synthesizer Characteristics
Frequency Accuracy
± 1.0 ppm internal reference (±0.01 ppm, option H)
Frequency Step
1 MHz(125 KHz, option X)
10 MHz In/Out Level
3 dBm ± 3 dB (option E)
Phase Noise
@ Freq 100Hz 1kHz 10kHz 100kHz 1MHz
dBc/Hz < -70 < -70 < -80 < -95 < -110
Available Options
Controls, Indicators
E - External 10 MHz reference
Freq/Gain Selection
direct readout LCD; manual or remote selection
H - High Stability (±0.01ppm) internal ref
Power; Alarm; Remote
Green LED; Red LED; Yellow LED
Q - RS485 Remote Interface
Remote
RS232C, 9600 baud (RS485, option Q)
T - Temperature Sensor
Other
X- 125 kHz frequency steps
V - SSPB Voltage, +24VDC, 2.5 amps
RF Connector
BNC (female), 50
Connectors/Impedance
IF Connector
BNC (female), 75
B - 75 BNC (RF), 75 BNC (IF)
10 MHz Connectors
BNC (female), 50/75
N - 50 N-type (RF), 75 BNC (IF)
Alarm/Remote Connector DB9 (female) - NO or NC contact closure on Alarm
M - 50 N-type (RF), 50 BNC (IF)
Size
19 inch, 1RU standard chassis 1.75”H X 16.0”D
S - 50 SMA (RF), 50 BNC (IF)
Power
100-240 ±!0% VAC, 47-63 Hz, 45 watts max
*10˚C to 40˚C; Specifications subject to change without notice
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road, Alpharetta, Georgia 30005
770-886-8005, FAX 770-886-7964
www.crosstechnologies.com
">