PV input range table
[Thermocouple]
C01
Sensor
Set value
type
1
K
2
K
3
K
4
K
5
K
6
K
9
J
10
J
11
J
13
E
14
T
15
R
16
S
17
B
18
N
19
PL II
20
WRe5-26
21
WRe5-26
24
DIN U
25
DIN L
Range
-200 to +1200°C
0 to 1200°C
0 to 800°C
0 to 600°C
0 to 400°C
-200 to +400°C
0 to 800°C
0 to 600°C
-200 to +400°C
0 to 600°C
-200 to +400°C
0 to 1600°C
0 to 1600°C
0 to 1800°C
0 to 1300°C
0 to 1300°C
0 to 1400°C
0 to 2300°C
-200 to +400°C
-100 to +800°C
[RTD]
C01
Set value
41
42
43
44
45
46
51
52
53
54
63
64
67
68
Sensor
type
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Pt100
JPt100
Operation
type
[DC voltage/DC current]
C01
Set value
84
86
87
88
89
90
Sensor
type
0 to 1V
1 to 5V
0 to 5V
0 to 10V
0 to 20mA
4 to 20mA
Scaling range is
-1999 to +9999.
*2: The indicated low limit for a B thermocouple is 20°C. However, if ROM version 1
of the instrument information bank (I d02) is prior to 2.04, the value is
-180°C.
*3: Thermocouple, RTD, and DC voltage/DC current are according to PV No. type.
List of alarm code
AL03
AL 1 1
AL70
Unit failure
AL95
AL96
AL97
AL98
AL99
PV input failure
(Over-range)
PV input failure
(Under-range)
CJ failure
PV input failure
(RTD)
CT input failure
(Over-range)
(CT input 1 or 2,
or both)
A/D conversion
failure
Parameter failure
Cause
Sensor burnout, incorrect
wiring, incorrect PV input
type setting
Sensor burnout, incorrect
wiring, incorrect PV input
type setting
Terminal temperature is
faulty (thermocouple).
Sensor burnout, incorrect
wiring
A current exceeding the
upper limit of the display
range was measured.
The number of CT turns
or the number of CT power
wire loops is incorrectly
set, or wiring is incorrect.
A/D converter is faulty.
Power is shut-down while
the data is being set, or
data is corrupted by noise.
Adjustment data
Power is shut-down while
failure
the data is being set, or
data is corrupted by noise.
Parameter failure Data is corrupted by
(RAM area)
noise.
Adjustment data
Data is corrupted by
failure (RAM area) noise.
ROM failure
ROM (memory) is faulty.
0
1
Reverse action
● shows that the ON/OFF is changed at this value.
O shows that the ON/OFF is changed at a point that
"1U" is added to this value.
Always OFF
Always OFF
HYS
Corrective action
Check the wiring.
Set the PV input type
again.
Check the ambient
temperature.
Check the wiring.
• Use a CT with the
correct number of turns
for the display range.
• Reset the number of CT
turns.
• Reset the number of CT
power wire loops.
• Check the wiring.
Replace the unit.
• Restart the unit.
• Set the data again (set
data for AL95/97 and
adjustment data for
AL96/98.
• Replace the unit.
• Reset the unit.
• Replace the unit.
ON
ON
HYS
Main setting
Main setting
PV
PV low
limit
2
ON
HYS
HYS
Main setting
PV high/
low limit
3
ON
ON
Sub-setting *
HYS
Deviation
high limit
(Final SP
reference)
Deviation
low limit
(Final SP
reference)
Deviation
high/low
limit
(Final SP
reference)
Heater 1
burnout/
Overcurrent
HYS
ON
PV
4
HYS
ON
ON
HYS
SP + Main setting PV
This guide offers a summary of key operations, parameter flowcharts, and settings, for
convenient reference at the operation site. This guide is made for repeated use. Dirt wipes
off easily and even notes written with an oil-based felt-tip pen can be removed with an
eraser. If more detailed information on the SDC15 is needed, refer to the user's manuals:
CP-SP-1147E for basic operation and CP-SP-1148E for installation and configuration.
The most convenient way to configure the SDC15 is with the Smart Loader Package
(model No. SLP-C35J50). Please contact the azbil Group or a distributor for more information.
5
ON
HYS
HYS
SP + Main setting
Deviation
high/low
limit
PV
Main setting * Sub-setting * PV
SP + Main setting PV
Deviation
low limit
ON
Main setting
PV
HYS
HYS
Main setting *
Deviation
high limit
PV
Quick Reference Guide
6
ON
HYS
HYS
ON
SP + Main setting
PV
ON
HYS
Main setting Sub-setting
PV
SP
PV
HYS
ON
Upper display
Indicators during AT
Main setting Sub-setting
SP
PV
7
HYS
ON
ON
HYS
Lower display
SP + Main setting PV
SP + Main setting PV
8
ON
HYS
HYS
SP + Main setting
ON
SP + Main setting
PV
[mode] key
Various indicators
Mode indicators
[para] key
[ ], [ ], and [ ] keys
PV
9
ON
HYS
HYS
ON
HYS
Main setting Sub-setting
PV
SP
HYS
ON
Main setting Sub-setting
SP
PV
16
ON
HYS
HYS
ON
HYS
Main setting *
Sub-setting *
CT1 at output ON
OFF before measuring the CT1 current value
Heater 1
shortcircuit
17
Heater 2
burnout/
Overcurrent
18
Heater 2
shortcircuit
19
Alarm
(status)
23
HYS
ON
ON
HYS
HYS
This display shows either the PV value or the display value and set value for
each displayed item. If an alarm is triggered, the normal display and alarm
code are displayed alternately. During auto tuning (AT), the rightmost decimal
point flashes twice repeatedly.
Lower display
This display shows either the SP/MV/CT or the display value and set value
for each displayed item. The rightmost decimal point lights up or flashes
to show RUN/READY mode or communications status, depending on the
setting.
Mode indicators
rdy:
man:
ev1, ev2, ev3:
ot1, ot2:
[mode] key
• When this key is pressed and held for more than 1 second in the operation
display mode, any of the following operations from 0 to 7 which have been
set previously can be executed:
0 : Mode key does not operate (Initial value)
1 : AUTO/MANUAL mode selection
2 : RUN/READY mode selection
3 : AT (Auto Tuning) start/stop selection
4 : LSP (Local SP) group selection
5 : Release all DO (Digital Output) latches
6 : Mode key does not operate
7 : ON/OFF selection of communication DI
• When pressing the [mode] key in the setup display mode, the display is
changed to the operation display
[para] key
• This key is used to change the display item.
• When this key is kept pressed for 2 sec. or longer in the operation display
mode, the display is then changed to the setup display
[<], [ ], [ ] keys
Theses keys are used to increase or decrease the numeric value, or to shift
the digit.
Loader connector
The Smart Loader connector is on the bottom of the SDC15.
HYS
OFF before measuring CT1 current value
ON
HYS
HYS
ON
Main setting *
Main setitng * Sub-setting *
CT2 at output ON
Sub-setting *
CT2 at output ON
OFF before measuring CT2 current value
HYS
Upper display
Main setting
CT1 at output OFF
OFF before measuring CT1 current value
ON
Sub-setting *
CT1 at output ON
OFF before measuring CT1 current value
Main setting
CT1 at output OFF
Loader connector
(bottom panel)
HYS
ON
Main setting *
OFF before measuirng CT2 current value
ON
ON
Main setting
CT2 at output OFF
OFF before measuring CT2 current value
HYS
Main setting
CT2 at output OFF
OFF before measuring CT2 current value
ON if alarm occurs (alarm code AL01 to 99).
OFF in other cases.
OFF if alarm occurs (alarm code AL01 to 99).
ON in other cases.
: initial value
*: If the main setting is greater than the sub-setting, operations are performed with the main
setting and sub-setting automatically swapped.
Event types other than the above:
Operation type
SP high limit
SP low limit
SP high/low limit
MV high limit
MV low limit
MV high/low limit
Set value
10
11
12
13
14
15
Operation type
Loop diagnosis 1
Loop diagnosis 2
Loop diagnosis 3
READY (status)
MANUAL (status)
Set value
20
21
22
24
25
Operation type
Set value
During AT (status)
27
During SP ramp
28
Control action (status)
29
ST setting standby (status)
30
Timer (status)
32
Handling precautions
• If ROM version 1 of the instrument information bank (I d02) is prior to 2.04, CT
input failure (AL 1 1) is not displayed.
Specifications are subject to change without notice.
(09)
URL: http://www.azbil.com
1st edition: Mar. 2007 (W)
2nd edition: Apr. 2012 (M)
8
<
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
<
Input failure
AL02
Failure name
No event
PV high
limit
Direct action
● shows that the ON/OFF is changed at this value.
O shows that the ON/OFF is changed at a point that
"1U" is added to this value.
Range
: Initial value
*1: PL II thermocouple is a range, which has been added to the units manufactured
form July, 2003.
Alarm
code
AL0 1
Set
value
Range
-200 to +500°C
-200 to +500°C
-200 to +200°C
-200 to +200°C
-100 to +300°C
-100 to +300°C
-50.0 to +200.0°C
-50.0 to +200.0°C
-50.0 to +100.0°C
-50.0 to +100.0°C
0 to 200.0°C
0 to 200.0°C
0 to 500°C
0 to 500°C
CP-SP-1213E
Event type
Lights when READY (RUN mode if not lit)
Lights when MANUAL (AUTO mode if not lit)
Lights when event relays are ON
Lights when the control output is ON (always lit when the
current output is used)
1
O Some items are not displayed depending on the availability of optional functions, model number, display setup
(C73 to C78) and display level (C79).
O Pressing [para] while changing settings has the effect of canceling and moving to the next item.
Flowchart of key operations and displays
Operation displays
When the power
is turned ON
PV value (3)
Manipulated
variable
LSP group
number
[para] key
SP value
MV value
SP value
2
PV value
Cool manipulated
variable
Heat manipulated
variable
MV value
MV value
AT progress
value
1
(1)
Upper and lower displays
remain off for 6s after
power ON. Each mode
indicator lights sequentially,
and then the operation
display appears.
2-second press
+ hold of
[para] key
[mode]
2-second press
+ hold of
[para] key
[SP]
[Event]
[PID]
CT2
CT1
Internal event 1
main setting
Current
value
Current
value
Setting value
Internal event 1
sub setting
Timer remaining
time
Setting value
Internal event 1
delay time
[para] key
Timer remaining
time 3
Internal event 3
sub setting
Internal event 3
main setting
Timer remaining
time 2
Internal event 2
sub setting
Internal event 2
main setting
Internal event 3
delay time
Setting value
Setting value
Internal event 2
delay time
Setting value
Setting value
to
Setting displays
2
[Parameter] [Extended tuning]
[Event configuration] [DI assignment] [DO assignment] [User function]
[Setup]
[Lock] [Instrument information]
(2)
For change
from MANUAL
to AUTO
For change
from AUTO
to MANUAL
1
[para] key
(3)
[para]
key
to
A
Key operations and displays
to
Continuous outputs
2
Control actions
to
Communications
(MANUAL)
Analog input
(AUTO)
SP
B
A
[para] key
to
B
2-second
press + hold
of [para] key
Notes:
(1) The parameters and numerical values registered as user functions UF
are displayed.
(2) If no key is pressed for 3 minutes, the display automatically returns
to 2 , PV display.
(3) If the [<] key is pressed while holding down the [para] key, various
displys/settings can be navigated in reverse order.
■ Explanation of arrows
[para] key
:
2-second press
+ hold of
[para] key
:
■ Movement through each setup menu
• [para] key
Forward movement
• [para] key + [<] key Backward movement
2
3
Press [para] twice.
The upper display
says at and the
lower display says
at.Of.
When [ ] or [ ] is
pressed, at.Of
flashes.
If the control method is
ON/OFF control and if
Bit 3 (AT stop/start
display) of the mode
display setting (C73) is
set to "disabled: 0,"
nothing is displayed.
Check that the
operation display
is displaying the
SP.
(If not, press [para]
repeatedly until the
SP is displayed.)
When the [<], [ ]
or [ ] key is pressed, the rightmost
digit on the lower
display flashes and
the SP can be
changed to the
desired value.
In this case, the
flashing of the
numerical value
implies that it is not
yet set. A numerical
setting that is being
changed flashes
the same way.
If no key is pressed
for more than 2s,
the displayed value
is set and the
display changes
from flashing to
continuously lit.
<
0 on the lower display
indicates that the event
operation type is set to
"none."
Start from the
operation display
(if necessary
press [mode] once
to get the operation display).
<
<
<
4 on the lower display indicates that the event operation type is
set for deviation high limit.
Similarly, use e2.C 1 to set the event 2 operation type, and
use e3.C 1 for event 3.
If an SP limit is in effect, the numerical
value cannot be changed to a value
above the limit. The SP limit must be
changed first.
4
If the [mode] key is
pressed when the
display is flashing, the
status returns to that of
step 1.
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
In case of ON/OFF
control, r--r appears
on the upper display.
Press [para]
repeatedly to get
e 1 on the upper
display. The lower
display says 0.
When [<], [ ] or
[ ] is pressed, the
rightmost digit on
the lower display
flashes, and can
be changed to the
desired value for
the event.
In this case, the
flashing of the
numerical value
implies that it is
not yet set.
A numerical setting that is being
changed flashes
the same way.
When [ ] or [ ] is
pressed, the lower
display flashes.
0 on the lower display
indicates that the event
main set value is "zero."
If the DI assignment is
set to "RUN/READY
selection," the display
does not flash and no
change can be made.
If no key is pressed
for more than 2s,
the displayed value
is set and the
display changes
from flashing to
continuously lit.
If no key is pressed for more than 2s, the displayed
value is set and the display changes from flashing
to continuously lit.
If the [mode] key is pressed when the display is flashing, the status
returns to that of step 1.
Setup of PID value
Similarly, use e2 to set a value for event 2, and e3 to set
a value for event 3.
Start from the
operation display
(if necessary press
[mode] once to
get the operation
display).
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
Press [para]
repeatedly to get
p-1 (for proportional band) on
the upper display.
The value set for
p-1 is displayed on
the lower display.
When [<], [ ] or
[ ] is pressed, the
rightmost digit on
the lower display
flashes, and can
be changed to the
desired value for
the proportional
band.
In this case, the
flashing of the
numerical value
implies that it is
not yet set. A
numerical setting
that is being
changed flashes
the same way.
If the control method is
"ON/OFF control,"
nothing is displayed.
To set hysteresis
as well, press
[para] once (or
twice, depending
on the settings) to
display e 1.hy on
the upper display.
The lower display
says 5.
5 on the lower display
indicates that the current
set value for event
hysteresis is 5.
When [<], [ ] or
[ ] is pressed, the
rightmost digit on
the lower display
flashes, and can
be changed to the
desired value for
hysteresis.
If no key is pressed
for more than 2s,
the displayed value
is set and the
display changes
from flashing to
continuously lit.
<
Setup of SP value
Press [para]
repeatedly to get
e 1.c 1 on the upper
display. 0 is
displayed on the
lower display.
<
When [ ] or [ ] is
pressed, run (or
rdy) on the lower
display flashes.
Start from the
operation display
(if necessary press
[mode] once to get
the operation
display).
>
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
When the [ ] or [ ] key is pressed, the rightmost
digit on the lower display flashes. Change the
flashing digit to 4 by pressing [ ] or [ ].
If no key is pressed for more than 2s, the
displayed value is set and the display changes
from flashing to continuously lit.
<
If no key is pressed
for more than 2s,
at.ON remains steadily lit and AT begins.
During AT, the rightmost decimal point
flashes twice repeatedly. (When AT
is done, the light
goes off and the
new PID values go
into effect.)
During the AT process, if the mode is changed to
READY or MANUAL, if PV input is faulty, or if a power
failure occurs, AT stops automatically without changing
the PID values.
AT can also be stopped by changing the setting from
At.ON to At.OF (return to step 3 above).
In this example, the event 1 operation type is set to
deviation high limit.
Press and hold
[para] for more
than 2s again to
get the setup
setting display.
The current set
value for C0 1
(PV input range
type) is displayed.
The current mode is
indicated by run for
RUN mode or rdy for
READY mode.
>
<
[Press [ ] once.
The lower display
starts to flash
at.On.
Setup of event operation type
Start from the
operation display
(if necessary
press [mode]
once to get the
operation display).
Flashing occurs only in
RUN and AUTO modes,
if there is no PV input
abnormality.
Also, if "AT stop/start" is
selected for DI assignment, the display does
not blink and no change
can be made.
Press the [para]
key once. The
upper display says
r--r and the lower
display says rdy
(or run).
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
<
<
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
<
When the [<], [ ]
or [ ] key is
pressed, the rightmost digit on the
lower display
flashes. If no key
is pressed for
more than 2s after
changing to the
desired value in
the PV input range
list, the display
changes from
flashing to continuously lit, and
the displayed
value is now set.
<
Press and hold
[para] for more
than 2s again to
get the setup
setting display.
The current set
value for C0 1
(PV input range
type) is displayed.
Start from the
operation display
(if necessary
press [mode]
once to get the
operation display).
Start from the
operation display
(if necessary press
[mode] once to get
the operation
display).
>
In case of ON/OFF
control, r--r appears
on the upper display.
AT forces ON/OFF of the MV a number of times (a limit
cycle) to calculate PID values.
Check that this operation does not create any problems
for the associated equipment before executing AT.
Setup of event value
>
If no sensor is connected,
an alarm for abnormal
PV input (any one from
AL0 1 to AL 1 1) may
appear on the upper
display.
RUN/READY mode selection
>
Press and hold
[para] for more
than 2s to get the
parameter setup
display. a--M is
shown on the
upper display.
Execution of auto tuning (AT)
>
Start from the
operation display
(if necessary
press [mode] once
to get the operation display).
: Items during operation
>
Setup of PV input range type
• For step numbers indicated in red like
, the following precaution applies:
If the key lock is set, the numerical value does not flash, and the value cannot be changed.
To change a numerical value, cancel the key lock first.
: Items before operation
>
Green letters
Blue letters
<
Operation examples
Similarly, use e2.hy to set a hysteresis value for event 2,
and e3.hy to set a hysteresis value for event 3.
Memo
The proportional band
can be set in a range
from 0.1 to 999.9%.
If no key is pressed for more than 2s, the
displayed value is set and the display changes
from flashing to continuously lit.
If the [mode] key is pressed when the display is flashing, the status
returns to that of step 1.
Similarly, use i-1 to set the integral time (0 to 9999s),
and d-1 to set the derivative time (0 to 9999s).
5
Et
List of operation displays
E2
Numeric value
E2. Sb
Numeric value
t2. --(Display example)
Numeric value
E3
Numeric value
E3. Sb
Numeric value
t3. --(Display example)
Numeric value
SP(Target value)
Contents
SP low limit to SP high limit
LSP group number
1 to LSP system group (Max. 4)
(1st digit=the right end digit)
MV (Manipulated Variable) -10.0 to +110.0%
Setting is enabled in MANUAL mode
(Numeric value flashed)
Heat MV (Manipulated Variable) Setting is disabled.
-10.0 to +110.0%
Cool MV (Manipulated Variable)
Initial value Setting value
0
1
JF.Ov
St.SA
St.Sb
St.Hb
St.ud
–
–
–
AT progress display
Setting is disabled.
(1st digit=the right end digit)
CT current value 1
Setting is disabled.
–
CT current value 2
Setting is disabled.
–
Internal Event 1 main setting
-1999 to +9999U or 0 to 9999U
0
Internal Event 1 remaining Setting is disabled.
L
time
" ", is displayed at the right end digit when using
the ON delay time, and "L" , the OFF delay time.
Internal Event 2 main setting Same as Internal Event 1 main setting
–
Internal Event 2 sub setting Same as Internal Event 1 sub setting
0
Internal Event 2 remaining Same as Internal Event 1 remaining time
time
Internal Event 3 main setting Same as Internal Event 1 main setting
–
Internal Event 3 sub setting Same as Internal Event 1 sub setting
0
Internal Event 3 remaining Same as Internal Event 1 remaining time
time
–
StUP
0
0
Display
C0 1
C02
C03
C04
C05
C06
C07
C08
C09
C 14
SP
Contents
Initial value Setting value
AUTO: AUTO mode MAN: MANUAL mode
AUTO
RUN: RUN mode RDY: READY mode
RUN
At. OF: AT stop At. ON: AT start
AT stop
Lt. ON: Latch continue Lt. OF: Latch release Latch continue
dI . OF: OFF dI . On: ON
OFF
Control action
[Mode bank]
[SP bank]
Ev
Contents
SP low limit to SP high limit
Item
Contents
Internal Event 1 to 5 main setting -1999 to +9999 or 0 to 9999
Internal Event 1 to 5 sub setting (The decimal point position may vary so that it
meets the operation type of the internal event)
Internal Event 1 to 5 hysteresis 0 to 9999
E 1.Hy to E5.Hy
(The decimal point position may vary so that it
meets the operation type of the internal event)
E 1.On to E5.On ● Internal Event 1 to 5 ON delay time 0.0 to 999.9 or 0 to 9999
E 1.Of to E5.Of ● Internal Event 1 to 5 OFF delay time
Display
P- 1
I-1
d- 1
rE- 1
OL- 1
OH- 1
P- 1C
I - 1C
d- 1C
OL. 1C
OH. 1C
Setting value
[Event bank]
Display
E 1 to E5
E 1.Sb to E5.Sb
PI D
Initial value
0
Initial value
0
Setting value
5
0
[PID bank]
●
●
●
●
Item
Proportional band (PID1)
Integral time (PID1)
Derivative time (PID1)
Manual reset (PID1)
MV low limit (PID1)
MV high limit (PID1)
Proportional band (cool) (PID1)
Integral time (cool) (PID1)
Derivative time (cool) (PID1)
Output low limit (cool) (PID1)
Output high limit (cool) (PID1)
Continuous output
Display
Item
SP- 1 to SP-4 SP of LSP 1 group to 4 group
Communication
SP
Contents
Initial value
0.1 to 999.9%
5.0
0 to 9999s (No integration control action when set at "0")
120
0 to 9999s (No derivative control action when set at "0")
30
-10.0 to +110.0%
50.0
-10.0 to +110.0%
0.0
-10.0 to +110.0%
100.0
0.1 to 999.9%
5.0
0 to 9999s (No integration control action when set at "0")
120
0 to 9999s (No derivative control action when set at "0")
30
-10.0 to +110.0%
0.0
-10.0 to +110.0%
100.0
Setting value
C 16
C 17
C 18
C 19
C20
C2 1
C22
C26
C27
C28
C29
C30
C32
C36
C37
C38
C39
C40
C4 1
C42
C43
C44
C45
C46
C47
C48
C49
C50
C5 1
C64
C65
C66
C67
C68
C69
C70
C7 1
C72
C73
C74
Item
Control method
At. OL
At. OH
dI FF
OFFS
FL
rA
bI
CyU
Cy
CyU2
Cy2
tP.ty
MV low limit at AT
MV high limit at AT
Differential (for ON/OFF control)
ON/OFF control action point offset
PV filter
PV ratio
PV bias
Time proportional cycle unit 1
Time proportional cycle 1
Time proportional cycle unit 2
Time proportional cycle 2
Time proportional cycle mode
SPU
SPd
●
●
●
●
●
● SP up ramp
● SP down ramp
Contents
Initial value
0: ON/OFF control 1: Fixed PID
0 or 1
2: ST(Self-tuning)
-10.0 to +110.0%
0.0
-10.0 to +110.0%
100.0
0 to 9999U
5
-1999 to +9999U
0
0.0 to 120.0s
0.0
0.001 to 9.999
1.000
-1999 to +9999U
0
0 to 3 *1
0
5 to 120s or 1 to 120s *2
10 or 2
0 to 3 *1
0
5 to 120s or 1 to 120s *2
10 or 2
0: Controllability aiming type
0 or 1
1: Operation end service life aiming type(Only ON/
OFF operation within Time proportional cycle)
0.0 to 999.9U(No ramp when set at "0.0U")
0.0
0.0
*1 0: Unit of "1s" 1: Fixed at 0.5s 2: Fixed at 0.2s 3: Fixed at 0.1s
*2 5 to 120s when output includes the relay output
Setting value
Key operation • display
Control
PV
SP Time proportional output
[Parameter bank]
Display
CtrL
Setting value
0
10.0
0.50
1.00
0
Item
Internal event 1 to 5 Configuration 1
Operation type
E 1.C2 to E5.C2
Internal event 1 to 5 Configuration 2
Operation type
1st digit: Direct/Reverse
2nd digit: Standby
3rd digit: EVENT state at READY
4th digit: Undefined
E 1.C3 to E5.C3 ● Internal event 1 to 5 Configuration 3
1st digit: Controller alarm OR
2nd digit: Special OFF setup
C76
C77
C78
C79
C80
C90
C9 1
C92
C93
U: Unit Maximum unit of Industrial volume in PV range (°C, Pa,L/min, etc.)
6
[Setup bank]
Contents
Initial value
Setting value
For details, refer to the PV Input Range Table Depending on Model No.
0: Celsius (°C) 1: Fahrenheit (°F)
0
●
0: Performed (internal) 1: Not performed (external)
0
0: No decimal point 1 to 3: 1 to 3 digits below decimal point
0
When the PV input type is DC voltage/DC current,
0
-1999 to +9999U
1000
●
PV input range low limit to PV input range
–
●
high limit
–
0.0 to 100.0% (PV square root extraction
0.0
●
is not performed when set at "0.0".)
Control action (Direct/Reverse) 0: Heat control (Reverse action)
0
1: Cool control (Direct action)
0
● Output operation at PV alarm 0: Control calculation is continued.
1: Output at PV alarm is output.
● Output at PV alarm
-10.0 to +110.0%
0.0
● Output at READY (Heat)
-10.0 to +110.0%
0.0
● Output at READY (Cool)
-10.0 to +110.0%
0.0
● Output operation at changing AUTO/MANUAL 0: Bumpless transfer 1: Preset
0
● Preset MANUAL value
-10.0 to +110.0%
0.0 or 50.0
● Initial output type of PID control
0: Auto 1: Not initialized 2: Initialized
0
● Initial output of PID control
-10.0 to +110.0%
0.0 or 50.0
Heat/Cool control
0: Not used 1: Used
0
● Heat/Cool selection
0: Normal 1: Energy saving
0
Heat/Cool control dead zone -100.0 to +100.0%
0.0
● Heat/Cool control change point -10.0 to +110.0%
50.0
LSP system group
1 to 4
1
● SP ramp unit
0: 0.1U/s 1: 0.1U/min 2: 0.1U/h
1
CT1 operation type
0: Heater burnout detection 1: Current value measurement
0
CT1 output
0 to 1: Control output 1 to 2, 2 to 4: Event output 1 to 3
0
CT1 measurement wait time 30 to 300ms
30
CT2 operation type
Same as CT1
0
CT2 output
Same as CT1
0
CT2 measurement wait time Same as CT1
30
Control output 1 range
1: 4 to 20mA 2: 0 to 20mA
1
Control output 1 type
0: MV 1: Heat MV 2: Cool MV 3: PV
0
4: PV before ratio, bias, and filter
5: SP 6: Deviation 7: CT1 current value
8: CT2 current value 10: SP+MV 11: PV+MV
Control output 1 scaling low limit -1999 to +9999U
0.0
Control output 1 scaling high limit
100.0
Control output 1 MV scaling
0 to 9999 (Valid when control output 1 type is 10 or 11)
200
Control output 2 range
Same as control output 1
1
Control output 2 type
Same as control output 1
3
Control output 2 scaling low limit Same as control output 1
0
Control output 2 scaling high limit Same as control output 1
1000
Control output 2 MV scaling
Same as control output 1
200
CPL/MODBUS
0: CPL 1: MODBUS (ASCII format)
0
2: MODBUS (RTU format)
Station address
0 to 127 (Communication is disabled when set at "0".)
0
Transmission speed (bps)
0: 4800 1: 9600 2: 19200 3: 38400
2
Data format (Data length)
0: 7 bits 1: 8 bits
1
Data format (Parity)
0: Even parity 1: Odd parity 2: No parity
0
Data format (Stop bit)
0: 1 bit 1: 2 bits
0
● Response time-out
1 to 250ms
3
● Key operation type
0: Standard type 1: Special type
0
[mode] key function
0: Invalid 1: AUTO/MANUAL selection
0
2: RUN/READY selection 3: AT Stop/Start
4: LSP group selection 5: Release all DO latches
6: Invalid 7: Communication DI1 selection 8: Invalid
● MODE display setup
Bit 0: AUTO/MANUAL display (Enabled: +1)
255
(Sum of the weighting)
Bit 1: RUN/READY display (Enabled: +2)
Bit 3: AT Stop/Start display (Enabled: +8)
Bit 4: Release all DO latches display (Enabled: +16)
Bit 5: Communication DI1 ON/OFF display (Enabled: +32)
Other invalid setting, 0, +4, +64, +128
Bit 0: PV display (Enabled: +1)
15
● PV/SP display setup
(Sum of the weighting)
Bit 1: SP display (Enabled: +2)
Bit 2: LSP group number display (Enabled: +4)
Other invalid setting, 0, +8
● MV display setup
Bit 0: MV display (Enabled: +1)
15
Bit 1: Heat MV/cool MV display (Enabled: +2)
(Sum of the weighting)
Bit 3: AT progress display (Enabled: +8)
Other invalid setting: 0, +4
● EV display setup
0: Not displayed
0
(Operation display)
1: Set value of Internal event 1 is displayed
2: Set values of Internal event 1 to 2 are displayed
3: Set values of Internal event 1 to 3 are displayed
● Timer remain time display setup
0: Not displayed
0
(Operation display)
1: Internal event 1 is displayed
2: Internal event 1 to 2 is displayed
3: Internal event 1 to 3 is displayed
● CT display setup
0: Not displayed 1: CT1 current value is displayed
1
(Operation display)
2: CT1 to 2 current values are displayed
User level
0: Simple configuration 1: Standard configuration
0
2: High function configuration
● Communication monitor
0: Not used
0
display
1: Flashing while data is sending through
RS-485 communication.
2: Flashing while data is receiving through
RS-485 communication
3: Logical OR of all DI statuses
4: Flashing in READY mode
● Number of CT1 turns
0: 800 turns 1 to 40: CT turns divided by 100
8
0: 1 time 1 to 6: Number of times
1
● Number of CT1 power wire loops
0: 800 turns 1 to 40: CT turns divided by 100
8
● Number of CT2 turns
0: 1 time 1 to 6: Number of times
1
● Number of CT2 power wire loops
di
Contents
Refer to event type (see page 8)
The digits are determined to 1st, 2nd, 3rd,
and 4th digit from the right end.
0: Direct 1: Reverse
0: None 1: Standby 2: Standby + Standby at SP change
0: Continue 1: Forced OFF
0
The digits are determined to 1st, 2nd, 3rd,
and 4th digit from the right end.
0: None 1: Alarm direct + OR operation
2: Alarm direct + AND operation
3: Alarm reverse + OR operation
4: Alarm reverse + AND operation
0: As usual
1: When the event set value (main setting)
is 0, the event is "OFF".
0: 0.1s 1: 1s 2: 1min
0
Item
Internal contact 1 to 3
Operation type
Item
PV input range type
Temperature unit
Cold junction compensation
Decimal point position
PV input range low limit
PV input range high limit
SP low limit
SP high limit
PV square root extraction dropout
dI 1.2 to dI 3.2 ● Internal contact 1 to 3
Input bit function
dI 1.3 to dI 3.3 ● Internal contact 1 to 3
Input assign A
dI 1.4 to dI 3.4 ● Internal contact 1 to 3
Input assign B
dI 1.5 to dI 3.5 ● Internal contact 1 to 3
Input assign C
dI 1.6 to dI 3.6 ● Internal contact 1 to 3
Input assign D
dI 1.7 to dI 3.7 ● Internal contact 1 to 3
Polarity A to D
1st digit: Polarity A
2nd digit: Polarity B
3rd digit: Polarity C
4th digit: Polarity D
dI 1.5 to dI 3.5 ● Internal contact 1 to 3 Polarity
dI 1.9 to dI 3.9 ● Internal contact 1 to 3
Event channel def.
Ot 1.5 to Ot2.5 ●
Ev 1.5 to Ev3.5
Ot 1.6 to Ot2.6 ●
Ev 1.6 to Ev3.6
Ot 1.7 to Ot2.7 ●
Ev 1.7 to Ev3.7
Ot 1.8 to Ot2.8 ●
Ev 1.8 to Ev3.8
Display
LOC
C.LOC
L.LOC
PASS
PS 1A
PS2A
PS 1b
PS2b
I d08
0
Contents
0: SDC15
XX. XX (2 digits after decimal point)
XX. XX (2 digits after decimal point)
Subtract 2000 from the year.
Example: "3" means the year 2003.
Month + day divided by 100.
Example: "12.01" means the 1st day of December.
Initial value Setting value
0
–
–
–
–
–
–
–
Precaution for setup
0
· The type of auto tuning can be changed by changing the value of At.ty (AT
type) in the extended tuning bank. Set it to match the control characteristics.
0
0
0: Direct 1: Reverse
0: Every Internal Event
1 to 5: Internal Event No.
Initial value Setting value
0
0
2: Contact 1
3: Contact 2
4: Contact 3
0
0
0
0
0
0
0
0
0
Changing the user level
Ot 1.4 to Ot2.4 ●
Ev 1.4 to Ev3.4
LOC
I d07
Item
ROM ID
ROM Version 1
ROM Version 2
Loader information
EST information
Manufacturing date code
(year)
● Manufacturing date code
(month, day)
● Serial No.
●
●
●
●
●
●
[DO assignment bank]
Ot 1.3 to Ot2.3 ●
Ev 1.3 to Ev3.3
Display
UF- 1 to UF-8
0
0
0
0
[Instrument information bank]
Display
I d0 1
I d02
I d03
I d04
I d05
I d06
Memo
Contents
0: No function 1: LSP group selection (0/+1)
2: LSP group selection (0/+2)
3: LSP group selection (0/+4) 4: Invalid
5: Invalid 6: Invalid 7: RUN/READY selection
8: AUTO/MANUAL selection
9: LSP/RSP selection 10: AT Stop/Start
11: ST disabled/enabled
12: Control action direct/reverse
13: SP Ramp enabled/disabled
14: PV Hold 15: PV Maximum value hold
16: PV Minimum value hold 17: Timer Stop/Start
18: Release all DO latches (Continue/Release)
19: Invalid 20: Invalid
0: Not used (Default input)
1: Function 1 ((A and B) or (C and D))
2: Function 2 ((A or B) and (C or D))
3: Function 3 (A or B or C or D)
4: Function 4 (A and B and C and D)
0: Normally opened 1: Normally closed
2: DI1 3: DI2 4 to 9: Undefined
10 to 14: Internal Event 1to 5
15 to 17: Undefined
18 to 21: Communication DI1 to 4
22: MANUAL 23: READY 24: Undefined
25: AT running 26: During SP ramp 27: Undefined
28: Alarm occurs 29: PV alarm occurs
30: Undefined 31: mode key pressing status
32: Event output 1 status 33: Control output 1 status
The digits are determined to 1st, 2nd, 3rd
and 4th digit from the right end.
0: Direct 1: Reverse
Display
Item
Ot 1. 1 to Ot2. 1 ● Operation type (Control output 1 to 2,
Ev 1. 1 to Ev3. 1
Event output 1 to 3)
Ot 1.2 to Ot2.2 ● Output assign A (Control output 1 to 2,
Ev 1.2 to Ev3.2
Event output 1 to 3)
UF
Initial value Setting value
0
[DI assignment bank]
Display
di 1. 1 to dI 3. 1
dO
Id
[Event configuration bank]
Display
E 1.C 1 to E5.C 1
in the lower right part of this page.
Changing the user level
Contents
0: Default output 1 to 2: MV1 to 2
3 to 6: Function 1 to 4
0: Normally opened 1: Normally closed
2 to 6: Internal Event 1 to 5
7 to 13: Undefined 14 to 15: MV1 to 2
16 to 17: Undefined 18 to 19: DI1 to 2
20 to 25: Undefined
Output assign B (Control output 1 to 2, 26 to 28: Internal Contact 1 to 3
Event output 1 to 3)
29 to 33: Undefined 34 to 37: DI1 to 4
38: MANUAL 39: READY 40: Undefined
Output assign C (Control output 1 to 2, 41: AT running 42: During SP ramp 43: Undefined
Event output 1 to 3)
44: Alarm occurs 45: PV alarm occurs
46: Undefined 47: Mode key pressing status
Output assign D (Control output 1 to 2, 48: Event output 1 status
Event output 1 to 3)
49: Control output 1 status
Control output 1 to 2, Event output The digits are determined to 1st, 2nd, 3rd,
1to 3 Polarity A to D
and 4 th digit from the right end.
1st digit: Polarity A
0: Direct 1: Reverse
2nd digit: Polarity B
3rd digit: Polarity C
4the digit: Polarity D
Polarity (Control output 1 to 2, 0: Direct 1: Reverse
Event output 1 to 3)
Latch (Control output 1 to 2, 0: None 1: Latch (Latch at ON)
Event output 1 to 3)
2: Latch (Latch at OFF except for initialization
at power ON)
Initial value Setting value
0
14: Output 1
15: Output 2
2: Event 1
3: Event 2
4: Event 3
0
0
0
0
0
0
0
0
0
[User function bank]
Item
● User function 1 to 8
Contents
–
Initial value Setting value
–
[Lock bank]
Item
Key lock
● Communication lock
● Loader lock
Password display
Password 1A
Password 2A
Password 1B
Password 2B
Contents
Initial value Setting value
0: All settings are possible
0
1: Mode, event, operation display, SP, UF, lock,
manual MV, [mode] key can be set
2: Operation display, SP, UF, lock,
manual MV, [mode] key can be set
3: UF, lock, manual MV, [mode] key can be set
0: read/write enabled 1: read/write disabled
0
0: read/write enabled 1: read/write disabled
0
0 to 15(5: Password 1A to 2B display)
0
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
0000 to FFFF (Hexadecimal value)
0000
7
This controller's user level can be set to 1 of 3 types in setup
C79.
The number of possible displays and settings decreases
according to the user level: high function > standard > simple. All items are displayed when high function is selected.
If necessary press
[mode] once to
change to the
operation display.
Next, press and
hold [para] for
more than 2s to
get the parameter
setup display. a--M
or r--r appears
on the upper display.
Press and hold
[para] for more
than 2s again to
display c 01 on the
upper display.
Press [para]
repeatedly to
change the upper
display to c 79
(user level).
When [<], [ ] or
[ ] is pressed, the
lower display
flashes and can be
changed to the
desired numerical
value. Then, if no
key is pressed for
more than 2s, the
displayed value is
set and the display
changes from
flashing to continuously lit.
<
C75
PARA
●
●
●
●
Initial value
1
0.30
0.0
1.00
1.00
1.00
0
List of setup setting displays
Internal Event 1 sub setting
Item
AUTO/MANUAL
RUN/READY
AT stop/start
Release all DO latches
Communication DI1
●
●
●
●
●
Contents
AT type
0: Normal 1: Immediate response 2: Stable *1
Just-FiTTER setting band
0.00 to 10.00
SP lag constant
0.0 to 999.9
Proportional band tuning factor at AT 0.00 to 99.99
Integral time adjust at AT
0.00 to 99.99
AT Derivative time adjust
0.00 to 99.99
0: PID(Conventional PID)
Control algorithm
1: Ra-PID(High-performance PID)
Just-FiTTER oversheet suppression factor 0 to 100
ST step execution resolution band 0.0 to 99.99
ST step setting band
0.0 to 10.00
ST hunting setting band
0.0 to 10.00
ST step ramp change
0: ST is executed when the PV moves up or down.
1: ST is executed only when the PV moves up.
3rd digit: Delay unit
4th digit: Undefined
List of parameter setting displays
Display
A--M
r--r
At
do Lt
C. dI 1
Item
–
C 15
MOdE
EvCF
[Extended tuning bank]
*1 Normal = Standard control characteristics, Immediate response = Control characteristics that respond immediately to external disturbance, Stable = Control characteristics having less up/down fluctuation of PV
Analog input
HEAt
Numeric value
COOL
Numeric value
PV
At 1 (Display example)
Ct 1
Numeric value
Ct2
Numeric value
E1
Numeric value
E 1. Sb
Numeric value
t 1. --(Display example)
Numeric value
Item
Display
At.ty
JF.bd
SP.LG
At-P
At-I
At-d
Ctr.A
• To change a user level, refer to
<
List of parameter
Display
Upper display: PV
Lower display: SP
PV
SP
LSP 1 (Display example)
LSP
PV
MV
• Items marked ● in the tables are displayed in standard and/or high function configuration.
: Essential parameters for PV measurement and control
: Basic parameters
: Required parameters when using optional functions
0: Simple configuration
(initial value)
1: Standard configuration
2: High function configuration
Was this manual useful for you? yes no