Skylla-i Battery Charger 24V
Li-Ion ready
www.victronenergy.com
Skylla-i (1+1): two outputs to charge 2 battery banks
The Skylla-i (1+1) features 2 isolated outputs. The second output, limited to approximately 4 A and with a
slightly lower output voltage, is intended to top up a starter battery.
Skylla-i (3): three full current outputs to charge 3 battery banks
The Skylla-i (3) features 3 isolated outputs. All outputs can supply the full rated output current.
Rugged
Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of
an adverse environment: heat, humidity and salt air.
Circuit boards are protected with an acrylic coating for maximum corrosion resistance.
Temperature sensors ensure that power components will always operate within specified limits, if needed
by automatic reduction of output current under extreme environmental conditions.
Skylla-i 24/100 (3)
Flexible
Next to a CAN bus (NMEA2000) interface, a rotary switch, DIP switches and potentiometers are available to
adapt the charge algorithm to a particular battery and its conditions of use.
Please refer to the manual for a complete overview of the possibilities
Important features:
The right amount of charge for a lead-acid battery: variable absorption time
When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of
the battery. After a deep discharge the absorption time is automatically increased to make sure that the
battery is completely recharged.
Preventing damage due to excessive gassing: the BatterySafe mode
If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage
has been chosen, the Skylla-i will prevent damage due to excessive gassing by automatically limiting the
rate of voltage increase once the gassing voltage has been reached
Less maintenance and aging when the battery is not in use: the Storage mode
The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In
the storage mode float voltage is reduced to 2,2 V/cell (26,4 V for 24 V battery) to minimise gassing and
corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’
the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early
battery failure.
To increase battery life: temperature compensation
Every Skylla-i comes with a battery temperature sensor. When connected, charge voltage will automatically
decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid
batteries and/or when important fluctuations of battery temperature are expected.
Battery voltage sense
In order to compensate for voltage loss due to cable resistance, the Skylla-i is provided with a voltage
sense facility so that the battery always receives the correct charge voltage.
Suitable for AC and DC supply (AC-DC and DC-DC operation)
The chargers also accept a DC supply.
Use as a power supply
As a result of the perfectly stabilized output voltage, the Skylla-i can be used as a power supply if batteries
or large buffer capacitors are not available.
Li-Ion (LiFePo4) ready
Simple charger on-off control can be implemented by connecting a relay or open collector optocoupler
output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of
voltage and current can be achieved by connecting to the galvanically isolated CAN bus port.
Learn more about batteries and battery charging
To learn more about batteries and charging batteries, please refer to our book ‘Energy Unlimited’ (available
free of charge from Victron Energy and downloadable from www.victronenergy.com).
Skylla-i
24/80 (1+1)
24/80 (3)
24/100 (1+1)
Input voltage (VAC)
24/100 (3)
230 V
Input voltage range (VAC)
185-265 V
Input voltage range (VDC)
180-350 V
Maximum AC input current @ 180 VAC
16 A
20 A
Frequency (Hz)
45-65 Hz
Power factor
0,98
Charge voltage 'absorption' (VDC) (1)
28,8 V
Charge voltage 'float' (VDC)
27,6 V
Charge voltage ‘storage’ (VDC)
26,4 V
Charge current (A) (2)
80 A
Charge current starter batt. (A)
4A
3 x 80 A
n. a.
Charge characteristic
3 x 100 A
100 A
(max total output: 80A)
(max total output: 100A)
4
n. a.
7 stage adaptive
Battery capacity (Ah)
400-800 Ah
500-1000 Ah
Charge curve, Li-Ion
4 stage, with on-off control or Can bus control
Temperature sensor
Yes
Can be used as power supply
Yes
Remote on-off port
Yes (can be connected to a Li-Ion BMS)
CAN bus communication port
Two RJ45 connectors, NMEA2000 protocol, galvanically isolated
Remote alarm relay
DPST
AC rating: 240VAC/4A
Forced cooling
DC rating: 4A up to 35VDC, 1A up to 60VDC
Yes
Protection
Battery reverse polarity (fuse)
Operating temp. range
Output short circuit
Over temperature
-20 to 60°C (Full output current up to 40°C)
Humidity (non condensing)
max 95%
ENCLOSURE
Material & Colour
aluminium (blue RAL 5012)
Battery-connection
M8 bolts
230 VAC-connection
screw-clamp 10mm² (AWG 7)
Protection category
IP 21
Weight kg (lbs)
Dimensions hxwxd in mm
(hxwxd in inches)
7 kg (16 lbs)
405 x 250 x 150 mm
(16.0 x 9.9 x 5.9 inch)
STANDARDS
Safety
EN 60335-1, EN 60335-2-29
Emission
EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity
1) Output voltage range 20-36V.
Can be set with rotary switch or
potentiometers.
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
2) Up to 40°C (100°F) ambient.
Output will reduce to 80% at 50°C, and to 60% at 60°C.
BMV 600S Battery Monitor
Skylla-i Control
The BMV 600S Battery Monitor features an
advanced microprocessor control system
combined with high resolution measuring
systems for battery voltage and
charge/discharge current.
The software includes complex calculation
algorithms, like Peukert’s formula, to exactly
determine the state of charge of the battery.
The BMV 600S selectively displays battery
voltage, battery current, consumed Ah or
time to go.
The Skylla-i Control panel provides remote
control and monitoring of the charge process
with LED status indication. In addition, the
remote panel also offers input current
adjustment that can be used to limit the input
current and thus the power drawn from the AC
supply. This is particularly useful when
operating the charger from limited shore
power or small gensets. The panel can also be
used to change several battery charging
parameters.
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: [email protected] | www.victronenergy.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement