46 3 us~v~Specification Sheet

46 3 us~v~Specification Sheet
HEAT RECOVERY VENTILATOR
VENMAR AVS 1.8 HE
PART NO. 45400
115 to 197 CFM (0.4 in. w.g.)
Controls
• This unit must be controlled by a main control. For a complete list
of main and optional auxiliary controls available, refer to the
Wall Control Compatibility Chart on last pages of wall controls
specification sheet, available at www.venmar.ca.
• For more details about controls, refer to the Main and auxiliary wall
controls user guide, also available at www.venmar.ca.
Options
• Integrated furnace interlock relay
• Complete line of registers and diffusers
• Electric duct heater
• Installation parts are available from your wholesaler
No Negative Pressure Defrost
VB0183
FOR HOMEOWNERS LOOKING FOR THE BEST
PERFORMANCE, ADDED VALUE, QUALITY AND
A LONGER WARRANTY
Recognized for its unsurpassed quality and superior craftsmanship,
the High Efficiency Series reflects a new level of exceptional
performance. It is guaranteed to satisfy the homeowner looking for
durability, reliability and performance.
• Vertical design
• All ports on top
• HomeShield™ patented defrost system; no negative pressure
• SilentSure™ quiet operation
• Low voltage connector for optional controls
REPAIRS AND MAINTENANCE
All parts of the 1.8 HE HRV can be removed quickly, allowing direct
access for easy repairs. The low power consumption PSC motors are
permanently lubricated. Even better, the entire motor subassembly
can be removed for easier maintenance. Finally, the electronic circuit
board eliminates electromechanical parts, reducing repair time to a
minimum.
WARRANTY
The 1.8 HE HRV is fully protected by a 5-year warranty on parts,
the best in the industry, and the heat recovery core is covered
by a lifetime warranty for as long as the buyer owns the house in which
the unit has been installed.
Available at:
The 1.8 HE HRV uses a unique defrost method. No negative pressure is
created by air exhausted to the outdoors, as the air is recirculated into
the house, helping to prevent any backdraft.
Filtered air
to building
Outdoor temperature
Stale air from
building
Defrost cycle
Defrosting min./
Operating min.
°C
°F
Warmer
than -5
Warmer
than 23
No defrost
-5 to -15
23 to 5
6/60
-15 to -27
5 to -19
6/32
-27 and less
-19 and less
6/20
VF0002
Heat Recovery Core
Dimensions: 15” x 28” x 14 3/8” (38 cm x 71 cm x 36.5 cm)
Exchange surface: 184 ft.² (17.1 m²)
Weight: 32 lb. (14 kg)
Type: Counterflow
Material: Polypropylene, light and easy to clean
Warranty: Limited lifetime
Requirements and standards
• Complies with the UL 1812 requirements regulating the installation
of Heat Recovery Ventilators
• Complies with the CSA C22.2 no. 113 Standard applicable to
ventilators
• Complies with the CSA C444 requirements regulating the installation
of Heat Recovery Ventilators
• Technical data were obtained from published results of tests relating
to CSA C439 Standards
• HVI certified
Dimensions: HRV 1.8 HE
23"
(58 cm)
8"ø
42¾"
(108.5 cm)
24"
(61 cm)
Energy Performance
GROSS AIR FLOW
SUPPLY
EXHAUST
M3/H
L/S
CFM
M3/H
L/S
CFM
M3/H
392 116 246 418 107 227 386
386 114 242 411 103 218 370
355 105 222 377 97 206 350
335 99 210 357 93 197 335
321 95 201 341 88 186 316
291 86 182 309 81 172 292
270 80 169 287 76 161 274
243 72 153 260 69 145 246
223 66 140 238 58 123 209
197 58 123 209 50 106 180
156 46
97
165 35
74
126
NET SUPPLY
AIR FLOW
CFM
231
227
209
197
189
171
159
143
131
116
92
6"ø
NET
AIR FLOW
SUPPLY T
°C °F
HEATING
0 32
0 32
0 32
0 32
-25 -13
COOLING
35 95
35 95
POWER
CONSUMED
APPARENT
SENSIBLE
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
EFFECTIVENESS
LATENT RECOVERY/
MOISTURE
TRANSFER
84
84
79
79
72
95
90
89
88
0.05
0.03
0.12
-0.04
L/S
CFM
M3/H
52
55
71
84
57
111
117
151
179
121
187
198
256
302
205
158
184
210
176
55 117 198
76 162 274
160
198
*
NOTE: All specifications are subject to change without notice.
VG0006A
External Static Pressure - Pascals
Ventilation Performance
L/S
109
107
99
93
89
81
75
68
62
55
43
6"ø
23"
(58 cm)
VK0010A
EXTERNAL
STATIC PRESSURE
PA
IN. W.G.
25
0.1
50
0.2
75
0.3
100
0.4
125
0.5
150
0.6
175
0.7
200
0.8
225
0.9
250
1.0
275
1.1
8"ø
TOTAL RECOVERY EFFICIENCY
13
15
325
300 • •
275
• •
250
••
SUPPLY
225
••
200
••
175
••
150
••
125
••
EXHAUST
100
••
75
••
50
••
25
••
0
20 40 60 80 100 120
Specifications
• Model: Venmar AVS 1.8 HE
• Filters: 20 ppi washable reticulated foam
• Part Number: 45400
• Housing: Pre-painted steel
• Total Assembled Weight (including
• Insulation: 3/4” (1.9 cm) expanded
polypropylene core): 140 lb. (63.5 kg)
- Low, increased low, high speed
- Low or increased low speed is
1/2” acoustic fiberglass wool
• Mounting:
- Fresh: 8” (20 cm)
- Two speeds available to user
polystyrene and
• Outgoing air duct connections:
- Stale: 6” (15.25 cm)
• Fan speed control:
selected at the time of installation
• Heat recovery core:
- Suspension by chains and springs
• Incoming air duct connections:
- Stale: 8” (20 cm)
- Heat exchange surface area:
• Supply and Exhaust blower motor:
184 ft² (17.1 m²)
2 motors
- Fresh: 6” (15.25 cm)
- Type: Counterflow
- Protection type: Thermally protected
• Drains: 1/2” (1.2 cm) fittings with
- Insulation class: B
- Material: Polypropylene
• Unit electrical characteristics:
10’ (3 m) PVC drain
Project:
Location:
Part no.: 45400
Qty.:
Submitted by:
120 V
60 Hz
250 W
2.5 A
REMARKS
Date:
Residential Products Group, 550 Lemire Blvd., Drummondville, Qc, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715
www.venmar.ca
1.8HEd151009
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project