Alto-Shaam 20-20 W, MW Holding Cabinet Installation / operation / service manual
Below you will find brief information for Holding Cabinet 20-20W, Holding Cabinet 20-20MW. This manual instructs on installing, operating, and servicing these holding cabinets. The holding cabinets are designed to maintain hot food at a temperature for safe consumption. The unit must be installed on a level surface in a location that will permit the equipment to function for its intended purpose and allow adequate access for proper cleaning and maintenance. The appliance is also designed to operate in conjunction with the Alto-Shaam Combitherm Combination Oven/Steamer.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
H o l d i n g C a b i n e t s
E l e c t r i c
Models:
20-20W
20-20MW
20-20MW
• InstallatIon
• operatIon
• MaIntenance
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 • 800.558.8744
USA
/
CANADA
FAX: 262.251.7067 • 800.329.8744
U
.
S
.
A
.
ONLY www.alto-shaam.com
p r i n t e d i n u .
s .
a . MN-36608 ( r e v
. 0) • 03/14
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Procedures and Precautions . . . . . . . . . . . . . . . 2
Installation
Installation Requirements . . . . . . . . . . . . . . . . . . . . 3
Clearance Requirements . . . . . . . . . . . . . . . . . . . . . 3
Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . 4
Options & Accessories . . . . . . . . . . . . . . . . . . . . . . 5
Product/Pan Capacities . . . . . . . . . . . . . . . . . . . . . 5
Electrical Specifications & Installation . . . . . . . . . . . 6
User Safety Information . . . . . . . . . . . . . . . . . . . . . 7
Heating Characteristics . . . . . . . . . . . . . . . . . . . . . 7
Operating Instructions
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . 8
General Holding Guidelines . . . . . . . . . . . . . . . . . . 9
Care and Cleaning
Cleaning and Preventative Maintenance . . . . . . . . 10
Protecting Stainless Steel Surfaces . . . . . . . . . . . 10
Cleaning Agents . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cleaning Materials . . . . . . . . . . . . . . . . . . . . . . . . 10
Equipment Care . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sanitation
Sanitation/Food Safety . . . . . . . . . . . . . . . . . . . . . 12
Internal Food Product Temperatures . . . . . . . . . . . 12
Service
Electronic Control Accuracy . . . . . . . . . . . . . . . . . 13
Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . 13
Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
20-20MW Service View and Parts List . . . . . . . 15-16
20-20W Service View and Parts List . . . . . . . . 17-18
Pan Cart (optional) . . . . . . . . . . . . . . . . . . . . . . . . 19
Always refer to the wire digram(s) included with the unit for most current version .
Warranty
Transportation Damage and Claims . . . . Back Cover
Limited Warranty . . . . . . . . . . . . . . . . . . Back Cover
i
d e l I v e r y
This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier.
See Transportation Damage and Claims section located in this manual.
This appliance, complete with unattached items and accessories, may have been delivered in one or more packages. Check to ensure that all standard items and options have been received with each model as ordered.
Save all the information and instructions packed with the appliance. Complete and return the warranty card to the factory as soon as possible to ensure prompt service in the event of a warranty parts and labor claim.
This manual must be read and understood by all people using or installing the equipment model. Contact the Alto-Shaam Tech Team Service
Department if you have any questions concerning installation, operation, or maintenance.
note: All claims for warranty must include the full model number and serial number of the unit.
U n p a c K I n g
1. Carefully remove the appliance from the carton or crate.
note: Do not discard the carton and other packaging material until you have inspected the unit for hidden damage and tested it for proper operation.
®
®
2. Read all instructions in this manual carefully before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators. Additional manuals are available from the Alto-Shaam
Tech Team Service Department.
3. Remove all protective plastic film, packaging materials, and accessories from the appliance before connecting electrical power. Store any accessories in a convenient place for future use.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 1
saFety procedUres and precaUtIons
Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual.
d a n g e r
Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
w a r n I n g
Used to indicate the presence of a hazard that CAN cause personal injury, possible death, or major property damage if the warning included with this symbol is ignored.
c a U t I o n
Used to indicate the presence of a hazard that can or will cause minor or moderate personal injury or property damage if the warning included with this symbol is ignored. c a U t I o n
Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
n o t e : Used to notify personnel of installation, operation, or maintenance information that is important but not hazard related.
1. This appliance is intended to cook, hold or process foods for the purpose of human consumption. No other use for this appliance is authorized or recommended.
2. This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
3. Any troubleshooting guides, component views, and parts lists included in this manual are for general reference only and are intended for use by qualified technical personnel.
4. This manual should be considered a permanent part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts lists, notices, and labels must remain with the appliance if the item is sold or moved to another location.
n o t e
For equipment delivered for use in any location regulated by the following directive:
DO NOT DISPOSE OF ELECTRICAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 2
I n s t a l l a t I o n s I t e I n s t a l l a t I o n
1. This appliance, complete with unattached items and accessories, may be delivered in one or more packages. Check to insure that all items ordered have been received.
This appliance is designed for the purpose of maintaining hot food at a temperature for safe consumption. The unit must be installed on a level surface in a location that will permit the equipment to function for its intended purpose and allow adequate access for proper cleaning and maintenance. d a n g e r
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
The appliance must not be installed in any area where it will be affected by steam, grease, dripping water, high temperatures, or any other severely adverse conditions.
c a U t I o n
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
Level the appliance from side-to-side and front-to-back with the use of a spirit level.
5. In order to maintain standards established by the National Sanitation Foundation, floor models must be sealed at bottom by NSF approved sealant, or equipped with casters, or 6” (152mm) legs to provide minimum unobstructed space beneath the unit. Warranty will become null and void if these directions are not followed.
clearance reQUIreMents back
3" (76mm) each top side
2" (51mm)
1" (25mm) weIght net ship
378 lb (171mm)
513 lb (233 kg)
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 3
Model 20-20Mw - Mobile
63" (1599mm) to MW bumper
61-5/16" (1557mm)
1-5/16" (33mm)
Cord Length: 9 ft. (2743mm)
I n s t a l l a t I o n
Model 20-20w - stationary
61-5/16" (1557mm)
1-5/16" (33mm)
Cord Length: 9 ft. (2743mm)
41" (1039mm)
35" (888mm) optional pan cart
34-1/2" (877mm)
41-5/16" (1049mm) to MW bumper
22" (558mm)
32-11/16" (830mm)
41" (1039mm)
34-1/2" (877mm)
22" (558mm)
28-5/8" (727mm) 26-7/8" (683mm)
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 4
28-5/8" (727mm) 26-7/8" (683mm)
I n s t a l l a t I o n optIons & accessorIes
Preheat Sealing Strip
Roll-In Pan Carts ( h x w x d )
20 shelf pan trolley
- Fits 20-20 e
, 20-20 g
, 20-20 mw
, and QC2-100
69-1/2" x 26-7/8" x 34-1/2" (1766 x 683 x 877mm)
2-9/16" (65mm) vertical spacing between shelves
20 shelf pan trolley
- Fits 20-10 e
, 20-10 g
, 20-20 mw
, and QC2-100
34-1/2" (877mm) 69-1/2" x 18-3/4" x 29-13/16" (1766 x 475 x 757mm)
2-9/16" (65mm) vertical spacing between shelves
Roll-In Plate Carts ( h x w x d )
102 plate trolley
- Fits 20-20 e
, 20-20 g
, 20-20 mw
, and QC2-100
69-5/8" x 26-7/8" x 42-1/2" (1769 x 683 x 1080mm)
3" (77mm) vertical spacing between shelves
84 plate trolley - Fits 20-20 e , 20-20 g , 20-20 mw , and QC2-100
69-5/8" x 26-7/8" x 42-1/2" (1769 x 683 x 1080mm)
3-11/16" (93mm) vertical spacing between shelves
60 plate trolley - Fits 20-10 e , 20-10 g , 20-20 mw , and QC2-100
69-13/16" x 18-3/4" x 37-1/8" (1773 x 475 x 943mm)
2-9/16" (66mm) vertical spacing between shelves
51 plate trolley - Fits 20-10 e , 20-10 g , 20-20 mw , and QC2-100
70" x 18-3/4" x 37-1/8" (1778 x 475 x 943mm)
3-1/16" (77mm) vertical spacing between shelves
5016989
5014652
5017148 ( ci
)
5015049
5017149 ( ci
)
5016478
5017150 ( ci
)
5016478
TROLLEY, 20-20
102 PLATE TROLLEY
32-1/16" (814mm)
5016480
5017151 ( ci )
5016489
5017153 ( ci )
5016490
5017154 ( ci ) preheat sealing strip
42-1/2" (1080mm) optional roll
in pan cart optional roll
in plate cart
SH-22473
28-5/8" (727mm) ci
- correctional institution roll-In pan cart prodUct\pan capacIty
480 lbs (218 kg) maximum volume maximum
: 300 quarts
(284 liters
)
Full-Size Pans: Forty (40) 20" x 12" x 2-1/2" maximum
GN 1/1: Forty (40) (530mm x 325mm x 65mm)
GN 2/1: Twenty (20) (650mm x 530mm x 65mm)
Full-Size Sheet Pans: Ten (10) 18" x 26" x 1"
Twenty (20) with added shelves
28-5/8" (728mm) 26-7/8" (683mm)
5016480
TROLLEY, 20-20
84 PLATE TROLLEY
32-1/16" (814mm)
42-1/2" (1080mm)
28-5/8" (728mm)
23-5/8" (600mm)
26-7/8" (683mm)
d a n g e r locK-oUt or post
BreaKer panel UntIl servIce worK has
Been coMpleted.
d a n g e r dIsconnect UnIt FroM power soUrce BeFore cleanIng or servIcIng.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 5
I n s t a l l a t I o n e l e c t r I c a l c o n n e c t I o n
1.
An identification tag is permanently mounted on the cabinet.
2.
Plug the unit into a properly grounded receptacle ONLY. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position.
3.
Position the unit so the cord is easily accessible in case of any emergencies. If necessary, a proper receptacle or outlet configuration, as required for the unit, must be installed by a licensed electrician in accordance with applicable, local electrical codes.
For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol.
note : Where local codes and CE regulatory requirements apply, appliances must be connected to an electrical circuit that is protected by an external GFCI outlet.
d a n g e r
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
d a n g e r
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
d a n g e r
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
hard wired models:
Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.
If a power cord is used for the connection of the product an oil resistant cord like H05RN or H07RN or equivalent must be used.
electrIcal voltage phase cycle
/ hz amps
kW
208 1 50/60 10.8 2.2 cord
& plug n e m a 6-15P
240 1 50/60 12.5 3.0 15A-250V Plug
230 1 50/60 12.0 2.8 plug cee rated ch
7/7
2-16
250v p plug rated 250v
BS 1363 ( u
.
k
. oNly
) plug rated
250v
Wire diagrams are located under the top cover of the unit .
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 6
o p e r a t I n g I n s t r U c t I o n s
U s e r s a F e t y I n F o r M a t I o n
This appliance is intended for use in commercial establishments where all operators are familiar with the purpose, limitations, and associated hazards of this appliance. Operating instructions and warnings must be read and understood by all operators and users.
1. Make sure the unit is connected to the appropriate power source.
2.
Use hand protection when handling hot items.
4.
Be certain only hot foods are placed
into the cabinet.
5. Do not operate this holding cabinet without the Roll-in Cart.
c a U t I o n
DO NOT OPERATE THIS
HOLDING CABINET WITHOUT ITS
APPROPRIATE ROLL-IN CART OR
PREHEAT SEALING STRIP.
heatIng characterIstIcs
The cabinet is equipped with a special, lowheat-density heating cable. Through the Halo
Heat concept, the heating cable is mounted against the walls of the warming compartment to provide an evenly applied heat source controlled by a thermostat. The design and operational characteristics of the cabinet eliminate the need for a moisture pan or a heat circulating fan. Through even heat application, the quality of a food product is maintained up to as much as several hours.
The primary purpose of the Model 20-20 Holding
Cabinet is to operate as a functional extension of the Combitherm Combination Oven/ Steamer. The combination oven is for high volume production – the Halo Heat companion holding cabinet preserves the quality and extends the longest possible holding life. The Roll-In Cart for the 20-20 are completely interchangeable between the Combitherm Oven and the Halo Heat Companion Holding Cabinet, along with compatible Alto-Shaam Quickchillers.
The Combitherm Combination Oven/Steamer, along with the Halo Heat companion holding cabinet and Alto-Shaam Quickchiller give the food service operator the advantage of advance full-load preparation, better work-load scheduling, and the ability to hold the product for prolonged periods without major deterioration.
BeFore InItIal Use:
Before operating the unit, clean both the interior and exterior with a clean, damp cloth and mild soap solution. Rinse carefully with a sponge and clean water. Clean and install the Roll-in Cart.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 7
operatIng InstrUctIons
1. preheat at 200°F (93°c) For
30 MInUtes BeFore loadIng Food.
Push power switch to “ON” position. The unit will begin operating at the previous set temperature.
2. Press the Up or Down Arrow Keys to 200°F (93°C).
Pressing and releasing the Arrow Keys will increase the set point by 1 degree. Pressing and holding the
Arrow Key will increase set point by 10 degrees.
When Arrow Key is released, a new set point temperature is set. The Set temperature will appear in the Digital Display and the Heat Indicator Light will illuminate. Press the Temperature Display Key for three seconds at any time to display the Actual inside air temperature.
To toggle between Set and Actual:
Factory default is to display Set temperature in the
Digital Display. To display Actual temperature:
Press and hold the Temperature Display Key and the Up Arrow Key for 5 seconds. The control will show ACT , then show the Actual temperature.
Repeat to toggle to Set point SET .
Press the Temperature Display Key at any time to display the alternate temperature.
3. When the inside air temperature reaches the desired holding temperature, the Heat Indicator Light will turn off.
4. Load the cabinet with hot food only.
The purpose of the holding cabinet is to maintain hot food at proper serving temperatures. Only hot food should be placed into the cabinet. Before loading the unit with food, use a food thermometer to make certain all food products are at an internal temperature range of 140° to 160°F (60° to 71°C).
All food not within the proper temperature range should be heated before loading into the holding cabinet.
5. Check to make certain the cabinet is securely closed, and using the Up and Down Arrow Keys, set the temperature to 160°F (71°C).
THIS WILL NOT NECESSARILY
BE THE FINAL SETTING.
The proper temperature range for the food being held will depend on the type and quantity of product. Whether or not the vents should be open or closed will also depend on the type of food being held. When holding food for prolonged periods, it is advisable to periodically check the internal temperature of each item to assure maintenance of the proper temperature range. Reset the holding temperature accordingly.
to toggle Between FahrenheIt/celsIUs
Press the Temperature Display Key at any time to display the alternate temperature.
The factory default is Fahrenheit. To change to Celsius:
Press and hold the Temperature Display Key and the Down Arrow Key for 5 seconds.
2. The control will show
.
C for 3 seconds to verify selection and then show the temperature. (Set Point or Actual, whichever the user has selected) in ºC.
3. Repeat to toggle to Fahrenheit.
Note: With a power failure, factory test, etc., the control will retain the ºC or ºF setting selected by the user when power is restored.
Beeper volUMe settIngs
To adjust beeper volume settings, press and hold both the Up and Down Arrow Keys for 5 seconds. Display will show current setting, and beeper will emit the sound of that setting. Press the Up or Down Arrow
Keys to cycle through the volume settings. Press the
Temperature Display key to select the desired setting.
Display Setting bPr0 Off bPr1 bPr2 bPr3
Low
Medium
High (factory default)
Heat Indicator
Light
Temperature
Display
Down
Arrow
Digital
Display
Up
Arrow
I I
Power
Switch
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 8
o p e r a t I n g I n s t r U c t I o n s
general holding guideline
Chefs, cooks and other specialized food service personnel employ varied methods of cooking.
Proper holding temperatures for a specific food product must be based on the moisture content of the product, product density, volume, and proper serving temperatures. Safe holding temperatures must also be correlated with palatability in determining the length of holding time for a specific product.
Halo Heat maintains the maximum amount of product moisture content without the addition of water, water vapor, or steam. Maintaining maximum natural product moisture preserves the natural flavor of the product and provides a more genuine taste. In addition to product moisture retention, the gentle properties of Halo Heat maintain a consistent temperature throughout the cabinet without the necessity of a heat distribution fan, thereby preventing further moisture loss due to evaporation or dehydration.
When product is removed from a high temperature cooking environment for immediate transfer into equipment with the lower temperature required for hot food holding, condensation can form on the outside of the product and on the inside of plastic containers used in self-service applications.
Allowing the product to release the initial steam and heat produced by high temperature cooking can alleviate this condition. To preserve the safety and quality of freshly cooked foods however, a maximum of 1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product.
This unit is equipped with a thermostat control between 60° and 205°F (16° and 96°C). If the unit is equipped with vents, close the vents for moist holding and open the vents for crisp holding. Use a metal-stemmed thermometer to measure the internal temperature of the product being held. Adjust the thermostat setting to achieve the best overall setting based on internal product temperature.
h o l d I n g t e M p e r a t U r e r a n g e
Meat
BEEF ROAST — Rare
BEEF ROAST — Med/Well Done
BEEF BRISKET
CORN BEEF
PASTRAMI
PRIME RIB — Rare
STEAKS — Broiled/Fried
RIBS — Beef or Pork
VEAL
HAM
PORK
LAMB poUltry
CHICKEN — Fried/Baked
DUCK
TURKEY
GENERAL
FIsh/seaFood
FISH — Baked/Fried
LOBSTER
SHRIMP — Fried
BaKed goods
BREADS/ROLLS
FahrenheIt
130°F
155°F
160° — 175°F
160° — 175°F
160° — 175°F
130°F
140° — 160°F
160°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
160° — 175°F
71° — 79°C
71° — 79°C
71° — 79°C
71° — 79°C
71° — 79°C
71° — 79°C
71° — 79°C
120° — 140°F 49° — 60°C
MIscellaneoUs
CASSEROLES
DOUGH — Proofing
EGGS —Fried
FROZEN ENTREES
HORS D'OEUVRES
PASTA
PIZZA
POTATOES
PLATED MEALS
SAUCES
SOUP
VEGETABLES
160° — 175°F
80° — 100°F
150° — 160°F
160° — 175°F
160° — 180°F
160° — 180°F
160° — 180°F
180°F
140° — 165°F
140° — 200°F
140° — 200°F
160° — 175°F
71° — 79°C
27° — 38°C
66° — 71°C
71° — 79°C
71° — 82°C
71° — 82°C
71° — 82°C
82°C
60°— 74°C
60° — 93°C
60° — 93°C
71° — 79°C
THE HOLDING TEMPERATURES LISTED ARE SUGGESTED GUIDELINES ONLY
.
ALL
FOOD HOLDING SHOULD BE BASED ON INTERNAL PRODUCT TEMPERATURES
.
ALWAYS FOLLOW LOCAL HEALTH
(
HYGIENE
)
REGULATIONS FOR ALL INTERNAL
TEMPERATURE REQUIREMENTS
.
celsIUs
54°C
68°C
71° — 79°C
71° — 79°C
71° — 79°C
54°C
60° — 71°C
71°C
71° — 79°C
71° — 79°C
71° — 79°C
71° — 79°C
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 9
c l e a n I n g a n d p r e v e n t a t I v e M a I n t e n a n c e protectIng staInless steel sUrFaces
It is important to guard against corrosion in the care of stainless steel surfaces. Harsh, corrosive, or inappropriate chemicals can completely destroy the protective surface layer of stainless steel. Abrasive pads, steel wool, or metal implements will abrade surfaces causing damage to this protective coating and will eventually result in areas of corrosion.
Even water, particularly hard water that contains high to moderate concentrations of chloride, will cause oxidation and pitting that result in rust and corrosion. In addition, many acidic foods spilled and left to remain on metal surfaces are contributing factors that will corrode surfaces.
Proper cleaning agents, materials, and methods are vital to maintaining the appearance and life of this appliance. Spilled foods should be removed and the area wiped as soon as possible but at the very least, a minimum of once a day.
Always thoroughly rinse surfaces after using a cleaning agent and wipe standing water as quickly as possible after rinsing.
cleanIng agents
Use non-abrasive cleaning products designed for use on stainless steel surfaces. Cleaning agents must be chloride-free compounds and must not contain quaternary salts. Never use hydrochloric acid (muriatic acid) on stainless steel surfaces.
Always use the proper cleaning agent at the manufacturer's recommended strength.
Contact your local cleaning supplier for product recommendations.
cleanIng MaterIals
The cleaning function can usually be accomplished with the proper cleaning agent and a soft, clean cloth. When more aggressive methods must be employed, use a non-abrasive scouring pad on difficult areas and make certain to scrub with the visible grain of surface metal to avoid surface scratches. Never use wire brushes, metal scouring pads, or scrapers to remove food residue.
c a U t I o n
N
O
SCRAPER
S
N
O
W
IRE
BRUS
H
E
S
N
O
ST
EEL PA
D
S
TO PROTECT STAINLESS STEEL
SURFACES, COMPLETELY AVOID
THE USE OF ABRASIVE CLEANING
COMPOUNDS, CHLORIDE BASED
CLEANERS, OR CLEANERS
CONTAINING QUATERNARY SALTS.
NEVER USE HYDROCHLORIC ACID
(MURIATIC ACID) ON STAINLESS
STEEL. NEVER USE WIRE
BRUSHES, METAL SCOURING
PADS OR SCRAPERS.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 10
The cleanliness and appearance of this unit will contribute considerably to operating efficiency and savory, appetizing food. Good equipment that is kept clean works better and lasts longer.
c a r e a n d c l e a n I n g
d a n g e r dIsconnect UnIt FroM power soUrce BeFore cleanIng or servIcIng.
clean the UnIt thoroUghly aFter each Use
Disconnect appliance from power source, and let cool.
2. Remove, cover or wrap, and store unused products under refrigeration.
3. Remove all detachable items such as plate carriers, wire shelves, side racks, and any drip pans. Clean these items separately.
4. Clean interior with a damp cloth or sponge and any good commercial detergent at the recommended strength.
Spray heavily soiled areas with a water soluble degreaser and let stand for 10 minutes, then remove soil with a plastic scouring pad.
note: Avoid the use of abrasive cleaning compounds, chloride based cleaners, or cleaners containing quaternary salts. Never use hydrochloric acid (muriatic acid) on stainless steel.
6. Clean control panel, door vents, door handles, and door gaskets thoroughly since these areas harbor food debris.
7. Rinse surfaces by wiping with sponge and clean warm water.
8. Remove excess water with sponge and wipe dry with a clean cloth or air dry. Leave door open until interior is completely dry. Replace shelves.
9. Interior can be wiped with a sanitizing solution after cleaning and rinsing. This solution must be approved for use on stainless steel food contact surfaces.
To help maintain the protective film coating on polished stainless steel, clean the exterior of the cabinet with a cleaner recommended for stainless steel surfaces. Spray the cleaning agent on a clean cloth and wipe with the grain of the stainless steel.
11. Clean glass with a window cleaner.
Cart Cleaning ––
Remove cart to a wash area and use any mild cleaning detergent and warm water. Handwipe all framing, slides, drip pan, and base. Thoroughly clean debris from the casters. A spray hose can be used for cart cleaning. Rinse detergent solution off with warm water. Wipe or spray with a sanitizing solution designed for use on metal and vinyl food contact surfaces. Allow cart to air dry.
d a n g e r
AT NO TIME SHOULD THE INTERIOR
OR EXTERIOR BE STEAM CLEANED,
HOSED DOWN, OR FLOODED WITH
WATER OR LIQUID SOLUTION OF
ANY KIND. DO NOT USE WATER JET
TO CLEAN.
severe daMage or electrIcal haZard coUld resUlt.
WARRANTY BECOMES VOID IF
APPLIANCE IS FLOODED
Always follow appropriate state or local health (hygiene) regulations regarding all applicable cleaning and sanitation requirements for foodservice equipment.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 11
s a n I t a t I o n
Food fl avor and aroma are usually so closely related that it is diffi cult, if not impossible, to separate them.
There is also an important, inseparable relationship between cleanliness and food fl avor. Cleanliness, top operating effi ciency, and appearance of equipment contribute considerably to savory, appetizing foods. Good equipment that is kept clean, works bett er and lasts longer.
The most accurate method of measuring safe temperatures of both hot and cold foods is by internal product temperature. A quality thermometer is an eff ective tool for this purpose, and should be routinely used on all products that require holding at a specifi c temperature.
Most food imparts its own particular aroma and many foods also absorb existing odors. Unfortunately, during this absorption there is not distinction between GOOD and BAD odors The majority of objectionable fl avors and odors troubling food service operations are caused by bacteria growth. Sourness, rancidity, mustiness, stale or other OFF fl avors are usually the result of germ activity.
The easiest way to insure full, natural food fl avor is through comprehensive cleanliness. This means good control of both visible soil (dirt) and invisible soil
(germs). A through approach to sanitation will provide essential cleanliness. It will assure an att ractive appearance of equipment, along with maximum effi ciency and utility. More importantly, a good sanitation program provides one of the key elements in the prevention of food-borne illnesses.
A controlled holding environment for prepared foods is just one of the important factors involved in the prevention of food-borne illnesses. Temperature monitoring and control during receiving, storage, preparation, and the service of foods are of equal importance.
A comprehensive sanitation program should focus on the training of staff in basic sanitation procedures. This includes personal hygiene, proper handling of raw foods, cooking to a safe internal product temperature, nd the routine monitoring of internal temperatures from receiving through service.
Most food-borne illnesses can be prevented through proper temperature control and a comprehensive program of sanitation. Both these factors are important to build quality service as the foundation of customer satisfaction. Safe food handling practices to prevent foodborne illness is of critical importance to the health and safety of your customers.
HACCP, an acronym for Hazard Analysis (at) Critical
Control Points, is a quality control program of operating procedures to assure food integrity, quality, and safety.
Taking steps necessary to augment food safety practices is both cost eff ective and relatively simple. While HACCP guidelines go far beyond the scope of this manual, additional information is available by contacting:
CENTER FOR FOOD SAFETY AND APPLIED
NUTRITION FOOD AND DRUG ADMINISTRATION
1-888-SAFEFOOD
INTERNAL FOOD PRODUCT TEMPERATURES
H OT FOOD S
DANGER ZONE 40° TO 140°F (4° TO 60°C)
CRITICAL ZONE
SAFE ZONE
DANGER ZONE
SAFE ZONE
DANGER ZONE
CRITICAL ZONE
SAFE ZONE
70° TO 120°F
140° TO 165°F
COLD FOOD S
ABOVE 40°F
36° TO 40°F
FROZEN FOOD S
ABOVE 32°F
0° TO 32°F
0°F or below
(21° TO 49°C)
(60° TO 74°C)
(ABOVE 4°C)
(2° TO 4°C)
(ABOVE 0°C)
(-18° TO 0°C)
(-18°C or below)
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 12
s e r v I c e electronIc control accUracy
The electronic control is a precise instrument and is designed to offer trouble-free service. If you suspect the temperature inside the warming cabinet does not match the temperature indicated on the digital display, after stabilizing, follow the instructions listed below.
1.
Check to make certain the unit voltage matches the power source. A power source less than that required to operate the unit will result in inaccurate temperatures.
2.
Verify the temperature inside the holding compartment with a quality thermal indicator.
A. With the exception of the wire shelves, completely empty the holding compartment.
B. Make certain the holding cabinet sensor, located inside the holding compartment at the left side of the unit, is completely clean.
C. Suspend the thermal indicator in the center of the holding compartment.
D. Allow the temperature set on the electronic thermostat to stabilize for a minimum of one hour before comparing the digital display with the reading on the thermal indicator.
DO NOT OPEN THE CABINET
DOOR(S) DURING THE TEMPERATURE
STABILIZATION PERIOD.
If the reading on the thermal indicator does not match the digital display, there may be a problem with the air sensor. See troubleshooting guide in this manual, or call the factory service department for advice.
specIal FeatUres heat recovery
The patented SureTemp™ heat recovery system in this unit will immediately compensate for any loss of heat when the door is opened. in order to maintain a more consistent cavity temperature, the control will automatically apply heat to the unit’s interior while the door is open and for a short time after the door is closed. If the door remains open for more than three minutes, the solid state electronic control will sound three rapid beeps every ten seconds until the door is closed.
d a n g e r dIsconnect UnIt FroM power soUrce BeFore cleanIng or servIcIng.
c a U t I o n
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
t r o U B l e s h o o t I n g
This section is provided for the assistance of qualified technicians only and is not intended for use by
untrained or unauthorized service personnel. If your Alto-Shaam ® unit is not operating properly, check the following before calling your Authorized Alto-Shaam ® Service Agent:
* Check main power circuit breaker to the unit and circuit breaker on the back of the unit is turned on, if applicable.
Do not attempt to repair or service the holding cabinet beyond this point. Contact Alto-Shaam ® for the nearest authorized service agent. Repairs made by any other service agents without prior authorization by Alto-Shaam
®
will void the warranty on the unit.
n o t e
If the appliance has been unplugged for an extended period of time, the Real Time Clock may require recharging. Turn main breaker to the unit off for 10 seconds and then restore power.
For more information, see Error Code E-60 in the Troubleshooting section of this manual.
d a n g e r locK-oUt or post
BreaKer panel UntIl servIce worK has
Been coMpleted.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 13
s e r v I c e
troUBleshootIng
code description possible cause e-10 e-11 e-20 product probe is shorted
Oven will cook in time only product probe is open e-21
Oven will cook in time only e-30 Under temperature e-31 cavity air sensor shorted cavity air sensor open over temperature
Cavity air sensor reading < 5°F. Verify sensor integrity.
See sensor test instructions below.
Cavity air sensor reading > 517°F. Verify sensor integrity.
See sensor test instructions below.
Product probe reading < 5°F. Verify sensor integrity.
See sensor test instructions below.
Product Probe reading > 517°F. Verify sensor integrity.
See sensor test instructions below.
Unit has not reached (set-point - 25°F) for more than 90 minutes.
Unit has been higher than 25°F above the maximum cavity set-point for more than 2 minutes. Note: Holding Cabinets with this error code are more than 145°F higher than the maximum set-point. e-32 safety switch open
(aux hi-limit switch)
Contact factory.
e-38 e-39 e-50 e-51 e-60 e-61 e-64 e-70
Internal software error sensor error temp. measurement error temp. measurement error real time clock error real time clock error clock is not oscillating configuration connector error (dIp switch)
Contact factory.
Contact factory.
Contact factory.
Contact factory.
Data set to factory default. Ensure that date and time are correct if applicable.
Contact factory.
Contact factory.
Refer to wiring diagram for the particular model and ensure dip switches on the control match the settings called out on the WD. If the dip switch settings are correct according to the print replace the control.
e-78 e-79 e-80 e-81 e-82 e-83 e-85 voltage low voltage high eeproM error eeproM error eeproM error eeproM error eeproM error
Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a
208-240 VAC unit. Correct voltage.
Voltage over 135 VAC on a 125 VAC unit, or over 250 VAC on a
208-240 VAC unit. Correct voltage.
Ensure that all temperatures and times are properly set.
Contact factory if problem persists.
Contact factory.
Contact factory.
Contact factory.
All timers, if previously on, are now off. Possible bad EEPROM.
e-86 e-87 e-88 e-90 e-91 e-ds eeproM error eeproM error eeproM error
Button stuck
Input failure datakey error
Stored HACCP memory corrupted. HACCP Address reset to 1. Possible bad
EEPROM. Contact factory if problem persists.
Stored offsets corrupted. Offsets reset to 0. Control may need a recalibration.
Possible bad EEPROM. Contact factory if problem persists.
All timer set-points are reset to 1 minute. Timers, if previously on, are now off. Possible bad EEPROM.
A button has been held down for >60 seconds. Adjust control. Error will reset when the problem has been resolved.
Contact factory.
Datakey digital signature incompatible. Cycle power, and install compatible
Datakey if error persists.
e-dt e-dU datakey error datakey unplugged
Datakey incompatible with control. Install compatible Datakey.
Install Datakey and cycle power to control to clear error.
dlto datalogger has timed out Cycle power. Contact factory if error persists.
dlsd Micro sd card not plugged in Plug in SD card and cycle power. Contact factory if error persists.
Note: If in doubt, always cycle the power to the control and contact factory if the problem persists.
to test probe and air sensor:
Tes t probe and air sensor by placing sensor in ice water bath and using an ohmmeter set on the ohm scale. The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs to be replaced .
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 14
servIce vIew - 20-20Mw
38
33
34
35
36
37
32
31 s e r v I c e
39
1
2
3
29
28
27
26
25
24
30
19
17
18
23 22
20
21
Part numbers and drawings are subject to change without notice .
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 15
15
16
7
4
7
8
9
5
6
10
11
12
13
14
s e r v I c e servIce parts lIst - 20-20Mw
IteM
1
2
3
4
5
6
7
8
9
10
11 descrIptIon part no. Qty IteM
BUSHInG, 1/2" HOLE BU-3006
HAnGER 6-1/2" ROPE CLEAT, 7/16 BLK nYLOn E2097HR
2
2
20
21 descrIptIon
CASTER,1 .5" STEM, 5" SWIVEL W/ BRAKE
CASTER, 5" RIGID, 1 .5" STEM W/BRAKE
SCREW, M5 x 0 .8 x 50mm FLAT
CORDSET
BUSHInG, STRAIGHT, STRAIn RELIEF
BACK PAnEL, SPOT
12 COnTROL
13
14
208-240V, nEMA 6-15P
230V, CEE 7/7
230V, BS 1363
230V, CH2-16P
LeFt hand 5016982
15 SCREW, M5 x 0 .8 x 10mm HEx
16 PAnEL, COnTROL SIDE ACCESS
17
T-BLOCK
THERMOSTAT, HI-LIMIT
PLUG, 3/8" HOLE
BAFFLE, HEAT COnTROL
BUSHInG, 3/4" WHITE SnAP
BUSHInG, 3/8" BLACK HOLE
COVER, BOTTOM
18 BUMPER BASE ASSEMBLY
19 SCREW, M5 x 0 .8 x 20mm HEx
RIGHT HAnD
SCREW, M5 x 0 .8 x 10mm PAn
LeFt hand
SC-35259
CD-3551
CD-3922
CD-33925
CD-3623
BU-3964
5017219
SC-22766
BK-3019
TT-33417
PG-25574
1015373
RIGHT HAnD 1015598
BU-3008
BU-3419
SC-23737
5017222
LeFt hand 1015357
RIGHT HAnD 1015599
5016986
4
1
1
1
1
1
1
1
29
1
1
1
1
1
CC-36403 1
1
1
6
1
1
1
1
SC-24391 13
22 contRoL paneL
23 BRACKET, TROLLEY GUIDE
24 DOOR ASSEMBLY
20-20 part no. Qty
CS-24875 2
CS-35290 2
LeFt hand 5016977 1
RIGHT HAnD 5017220
1015573
20-10 1015611
LeFt hand 5016976
RIGHT HAnD 5017221
1
25 HAnDLE, DOOR LeFt hand HD-26967 1
RIGHT HAnD HD-26966 1
26 SWITCH,ROCKER,125-277V,20A SW-34769 1
27
28
PAnEL OVERLAY
TRAnSPORT HAnDLE
29 SCREW, M6 x 1 .0 x 30mm FLAT
30 SCREW, M5 x 0 .8 x 30mm FLAT
31
32
DOOR GASKET
TRIM, FROnT
33 TUBE InSULATIOn
34 InSULATIOn, TRS-30, FIBERGLASS,176
35
36
37 PAnEL, COnTROL SIDE ACCESS
39 COVER, TOP LeFt hand
1015370
1015356
39
ELEMEnT,1500W, T-SHAPE FOIL
GASKET, FOAM 31 .5" LEnGTH
RIGHT HAnD
PE-36464
HD-22257
SC-27284
SC-22853
GS-36417
1015354
5016988
In-22364
EL-36365
GS-23622
1015600
SCREW M4 x 0 .7 x 30 PAn PHH SST A2 MS SC-29276
1
1
1
1
1
2
5
18
1
1
1
2
2
1
1
1
1
2
d a n g e r dIsconnect UnIt FroM power soUrce BeFore cleanIng or servIcIng.
d a n g e r locK-oUt or post
BreaKer panel UntIl servIce worK has
Been coMpleted.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 16
26
25
24
23
22 servIce vIew - 20-20w
35
34
33
32
31
30
29
28
27 s e r v I c e
36
1
2 3
4
10
11
12
13
14
15
16
7
8
9
7
5
6
17
18
19
20
21
Part numbers and drawings are subject to change without notice .
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 17
s e r v I c e servIce parts lIst - 20-20w
IteM
1
2
3
4 descrIptIon part no. Qty IteM
BUSHInG, 1/2" HOLE BU-3006
HAnGER 6-1/2" ROPE CLEAT, 7/16 BLK nYLOn E2097HR
2
2
19
20 descrIptIon
6" LEG W/ ADJUSTABLE FLAnGED FOOT contRoL paneL LeFt hand part no. Qty
LG-23067
5016977
4
1
SCREW, M5 x 0 .8 x 50mm FLAT
CORDSET 208-240V, nEMA 6-15P
230V, CEE 7/7
230V, BS 1363
SC-35259
CD-3551
CD-3922
CD-33925
4
1
1
1
21 BRACKET, TROLLEY GUIDE
22 DOOR ASSEMBLY
RIGHT HAnD 5017220
20-20 1015573
20-10 1015611
LeFt hand 5016976
1
1
1
1
5
6
7
8
9
230V, CH2-16P CD-3623
BUSHInG, STRAIGHT, STRAIn RELIEF BU-3964
BACK PAnEL, SPOT LeFt hand 5016982
RIGHT HAnD 5017219
SCREW, M5 x 0 .8 x 10mm PAn
T-BLOCK
THERMOSTAT, HI-LIMIT
10 PLUG, 3/8" HOLE
11 BAFFLE, HEAT COnTROL
12 COnTROL
LeFt hand
SC-22766
BK-3019
TT-33417
PG-25574
1015373
RIGHT HAnD 1015598
1
1
1
1
29
1
1
1
1
1
CC-36403 1
13 BUSHInG, 3/4" WHITE SnAP
14 BUSHInG, 3/8" BLACK HOLE
15 SCREW, M5 x 0 .8 x 10mm HEx
16 PAnEL, COnTROL SIDE ACCESS
17 COVER, BOTTOM
18 ADAPTER, 1 .5 SQ TUBE
BU-3008
BU-3419
LeFt hand 1015357
RIGHT HAnD 1015599
5011759
1
1
SC-23737 6
5017222 1
1
1
4
23 HAnDLE, DOOR
RIGHT HAnD 5017221 1
LeFt hand HD-26967 1
RIGHT HAnD HD-26966 1
24 SWITCH, ROCKER,125-277V,20A
25 PAnEL OVERLAY
26 PLUG, SHEET METAL, FInISHED HEAD
27 SCREW, M5 x 0 .8 x 30mm FLAT
SW-34769
PE-36464
1
1
PG-36642 4
SC-22853 18
28 DOOR GASKET
29 TRIM, FROnT
30 TUBE InSULATIOn
31 InSULATIOn, TRS-30, FIBERGLASS,176
GS-36417 1
1015354 1
5016988
In-22364
1
2
32 ELEMEnT, 1500W, T-SHAPE FOIL
33 GASKET, FOAM 31 .5" LEnGTH
EL-36365 2
GS-23622 1
34 PAnEL, COnTROL SIDE ACCESS
35 COVER, TOP LeFt hand
1015370
1015356
1
1
RIGHT HAnD 1015600 1
36 SCREW M4 x 0 .7 x 30 PAn PHH SST A2 MS SC-29276 2
d a n g e r dIsconnect UnIt FroM power soUrce BeFore cleanIng or servIcIng.
d a n g e r locK-oUt or post
BreaKer panel UntIl servIce worK has
Been coMpleted.
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 18
34-1/2" (877mm)
22" (558mm) pan cart ( optional
) s e r v I c e a c f e d b descrIptIon
1 TROLLEY RACK ASSEMBLY
2 CASTER, SWIVEL, nO BRAKE
3 CASTER, SWIVEL, WITH BRAKE
4 SCREW, M4x0 .7x10MM HEx
5 ROD, TROLLEY LOCK
6 TROLLEY HAnDLE part no.
Qty
5014652 2
CS-36218
CS-36219
2
2
SC-23664
1014124
1014856
2
2
1
Part numbers and drawings are subject to change without notice .
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 19
28-5/8" (727mm) 26-7/8" (683mm)
MN-36608 ( rev
. 0) • 20-20MW, 20-20W • iNstallatioN
/ operatioN
/ service MaNual
- pg
. 20
TRANSPORTATION DAMAGE and CLAIMS
All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee.
Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases, the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be established on the part of the shipper.
1. Make an immediate inspection while the equipment is still in the truck or immediately after it is moved to the receiving area.
Do not wait until after the material is moved to a storage area.
2. Do not sign a delivery receipt or a freight bill until you have made a proper count and inspection of all merchandise received.
3. Note all damage to packages directly on the carrier’s delivery receipt.
4. Make certain the driver signs this receipt. If he refuses to sign, make a notation of this refusal on the receipt.
5. If the driver refuses to allow inspection, write the following on the delivery receipt:
Driver refuses to allow inspection of containers for visible damage.
6. Telephone the carrier’s office immediately upon finding damage, and request an inspection. Mail a written confirmation of the time, date, and the person called.
7. Save any packages and packing material for further inspection by the carrier.
8. Promptly file a written claim with the carrier and attach copies of all supporting paperwork.
We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued.
We cannot, however, file any damage claims for you, assume the responsibility of any claims, or accept deductions in payment for such claims.
LIMITED WARRANTY
Alto-Shaam, Inc. warrants to the original purchaser only that any original part that is found to be defective in material or workmanship will, at
Alto-Shaam's option, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.
The original parts warranty period is as follows:
For the refrigeration compressor on Alto-Shaam Quickchillers ™ , five (5) years from the date of installation of appliance.
For the heating element on Halo Heat® cooking and holding ovens, as long as the original purchaser owns the oven. This excludes holding only equipment.
For all other original parts, one (1) year from the date of installation of appliance or fifteen (15) months from the shipping date, whichever occurs first.
The labor warranty period is one (1) year from the date of installation or fifteen (15) months from the shipping date, whichever occurs first.
Alto-Shaam will bear normal labor charges performed during standard business hours, excluding overtime, holiday rates or any additional fees.
To be valid, a warranty claim must be asserted during the applicable warranty period. This warranty is not transferable.
THIS WARRANTY DOES NOT APPLY TO:
1. Calibration.
2. Replacement of light bulbs, door gaskets, and/or the replacement of glass due to damage of any kind.
3. Equipment damage caused by accident, shipping, improper installation or alteration.
4. Equipment used under conditions of abuse, misuse, carelessness or abnormal conditions, including but not limited to, equipment subjected to harsh or inappropriate chemicals, including but not limited to, compounds containing chloride or quaternary salts, poor water quality, or equipment with missing or altered serial numbers.
5. Damage incurred as a direct result of poor water quality, inadequate maintenance of steam generators and/or surfaces affected by water quality. Water quality and required maintenance of steam generating equipment is the responsibility of the owner/operator.
6. Damage caused by use of any cleaning agent other than Alto-Shaam's Combitherm chlorine or other harmful chemicals. Use of Alto-Shaam's Combitherm ®
® Cleaner, including but not limited to damage due to
Cleaner on Combitherm ® ovens is highly recommended.
7. Any losses or damage resulting from malfunction, including loss of product, food product, revenue, or consequential or incidental damages of any kind.
8. Equipment modified in any manner from original model, substitution of parts other than factory authorized parts, removal of any parts including legs, or addition of any parts.
This warranty is exclusive and is in lieu of all other warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall Alto-Shaam be liable for loss of use, loss of revenue or profit, or loss of product, or for any indirect, special, incidental, or consequential damages. No person except an officer of Alto-Shaam, Inc. is authorized to modify this warranty or to incur on behalf of Alto-Shaam any other obligation or liability in connection with Alto-Shaam equipment.
Effective November 1, 2012
RECORD THE MODEL AND SERIAL NUMBER OF THE APPLIANCE FOR EASY REFERENCE.
ALWAYS REFER TO BOTH MODEL AND SERIAL NUMBER IN ANY CONTACT WITH ALTO-SHAAM REGARDING THIS APPLIANCE.
Model: ______________________________________________ Date Installed: ______________________________________________________
Voltage: ______________________________________________ Purchased From: ___________________________________________
Serial Number: _____________________________________________________________________________________________________________
W 1 6 4 N 9 2 2 1 W a t e r S t r e e t
●
P . O . B o x 4 5 0
●
M e n o m o n e e F a l l s , W i s c o n s i n 5 3 0 5 2 - 0 4 5 0
●
U . S . A .
PHONE: 262.251.3800 • 800.558-8744
USA
/
CANADA
FAX: 262.251.7067 • 800.329.8744
U
.
S
.
A
.
ONLY www.alto-shaam.com
P R I N T E D I N U
.
S
.
A
.
advertisement
Key Features
- Halo Heat concept
- Even heat application
- Moisture control
- Roll-in Cart
- Temperature control
- SureTemp™ heat recovery system
- Error Code display
- Easy to clean
Frequently Answers and Questions
How do I preheat the holding cabinet?
What is the proper temperature range for holding food?
How do I clean the holding cabinet?
Related manuals
advertisement
Table of contents
- 3 Delivery
- 3 Unpacking
- 4 Safety Procedures and Precautions
- 5 Installation Requirements
- 5 Clearance Requirements
- 6 Dimension Drawings
- 7 Options & Accessories
- 7 Product/Pan Capacities
- 8 Electrical Specifications & Installation
- 9 User Safety Information
- 9 Heating Characteristics
- 10 Operating Instructions
- 11 General Holding Guidelines
- 12 Cleaning and Preventative Maintenance
- 12 Protecting Stainless Steel Surfaces
- 12 Cleaning Agents
- 12 Cleaning Materials
- 13 Equipment Care
- 14 Sanitation/Food Safety
- 14 Internal Food Product Temperatures
- 15 Electronic Control Accuracy
- 15 Trouble Shooting Guide
- 16 Error Codes
- 17 20-20MW Service View and Parts List
- 19 20-20W Service View and Parts List
- 21 Pan Cart (optional)