12 20 s ct
Products 2012
Sensitivity
Accuracy
Quality
Simplicity
Company Profile
Great Value
in Test & Measurement
HAMEG Instruments – committed to medium sized companies
HAMEG Instruments GmbH prides itself on over 50 years
of a successful company history. Since the company’s
foundation in 1957, the name HAMEG stands for inno­
vation, user friendliness, longevity, high quality of
workmanship, and especially an excellent price/per­
formance ratio. An independent company, a member of
the Rohde & Schwarz Group since April 2005, HAMEG
is located at Mainhausen near Frankfurt, Germany and
develops and distributes its electronic measuring
instruments via a global network of competent service
and sales partners in more than 60 countries.
The enduring success of the HAMEG Instruments is
based upon the principles of Sensitivity, Accuracy,
Quality and, finally, Simplicity. The company’s philos­
ophy is to design electronic measuring instruments
which not only guarantee excellent performance and
reliability but also offer the greatest possible flexibility,
which is of equal importance in every day laboratory,
test and production applications. HAMEG measuring
instruments concentrate on the essentials. The opera­
tion of the instruments is intentionally kept as simple
as possible while retaining important functions.
HAMEG customers come from industry, small busi­
nesses, science, schools and universities, service and
last but not least, due to the good price/performance
ratio, from the ambitioned hobbyists. Numerous gen­
erations of professional engineers, technicians and
craftsmen used HAMEG Instruments during their basic
training and also in advanced applications of measure­
ment technology.
All HAMEG Instruments conform to a standard width,
so stacks of several instruments are possible. Due to
this feature and the compact sizes they require little
space in the working area.
2
Table of contents
Oscilloscopes
4
HMO3524
350 MHz 4 Channel Digital Oscilloscope 6
HMO3522
350 MHz 2 Channel Digital Oscilloscope 6
HMO2524
250 MHz 4 Channel Digital Oscilloscope 7
HMO2024
200 MHz 4 Channel Digital Oscilloscope 8
HMO2022
200 MHz 2 Channel Digital Oscilloscope 8
HMO1524
150 MHz 4 Channel Digital Oscilloscope 8
HMO1522
150 MHz 2 Channel Digital Oscilloscope 8
HMO1024
100 MHz 4 Channel Digital Oscilloscope 9
HMO1022
100 MHz 2 Channel Digital Oscilloscope 9
HMO724
70 MHz 4 Channel Digital Oscilloscope
9
HMO722
70 MHz 2 Channel Digital Oscilloscope
9
HOO11
Serial Bus (Analog Channel)
10
HOO10
Serial Bus (Analog & Digital Channel) 10
HM400
40 MHz Analog Oscilloscope
11
Modular System Series 8000
HM8001-2
Mainframe
HM8012
4¾-Digit Programmable Multimeter
HM8018
25 kHz LCR-Meter
HM8021-4
1.6 GHz Universal Counter
HM8030-6
10 MHz Function Generator
HM8040-3
Triple Power Supply (Module)
2 x 0…20 V/0.5 A and 1 x 5 V/1 A
HM800
Blank Module
36
38
39
39
40
40
Options
HO118
HO3508
HO3011
HOO10
HOO11
HO730
HO740
HO880
42
43
43
44
44
44
45
45
45
Binning Interface
Logic Probe
Preamplifier
Serial Bus (Analog & Digital Channel)
Serial Bus (Analog Channel)
Dual Ethernet/USB Interface
IEEE-488 (GPIB) Interface
IEEE-488 (GPIB) Interface
41
41
Spectrum Analysis
HMS3010
3 GHz Spectrum Analyzer
with Tracking-Generator
HMS3000
3 GHz Spectrum Analyzer
HMS1010
1 GHz Spectrum Analyzer
with Tracking-Generator
HMS1000
1 GHz Spectrum Analyzer
HMS1000E
1 GHz Spectrum Analyzer
HM6050-2
Line Impedance Stabilization Network
HZ540/HZ550 EMV Near-Field Probe Set up to 3 GHz
HZ530
EMV Near-Field Probe Set up to 1 GHz
12
Power Supplies
HMP4040
Programmable 4 Channel
High-Performance Power Supply
HMP4030
Programmable 3 Channel
High-Performance Power Supply
HMP2030
Programmable 3 Channel
High-Performance Power Supply
HMP2020
Programmable 2 Channel
High-Performance Power Supply
HM7042-5
Triple Power Supply
2 x 0…32 V/0…2 A and 1 x 0…5.5 V/0…5 A
HM8143
Arbitrary Power Supply
2 x 0…30 V/0…2 A and 1 x 5 V/0…2 A
20
25
Index
93
Programmable Measuring Instruments Series 8100
HMF2550
50 MHz Arbitrary Function Generator
HMF2525
25 MHz Arbitrary Function Generator
HM8112-3
6½-Digit Precision Multimeter
8 kW Power Meter
HM8115-2
HM8118
200kHz LCR-Bridge
HM8123
3 GHz Programmable Counter
HM8134-3
1.2 GHz RF-Synthesizer
HM8135
3 GHz RF-Synthesizer
HM8150
12.5 MHz Arbitrary Function Generator
26
28
28
29
30
31
32
33
34
35
Contact
93
14
14
14
14
15
17
18
19
Accessories
Test Cables
Test Cables/Adapter
Adapter/Interfaces/Cables
Probes
Converter/Sensors/Test fixtures
HM8118/Test Adapter
Spectrum Analyzer
Rackmount Kits
Rackmount Kits/Carrying Cases
46
47
48
49
50
55
56
57
58
59
Specifications
Oscilloscopes
Spectrum Analyzers
Power Supplies
Programmable Measuring Instruments Series 8100
Modular System Series 8000
HOO10/HOO11
HOO12 CAN/LIN
60
61
72
74
76
84
89
90
22
22
23
23
24
3
Oscilloscopes
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring
Instruments Series 8100
Modular System Series 8000
Options
Accessories
Specifications
4
Oscilloscopes
HAMEG
Oscilloscopes
Innovation right from the start
Without doubt, the oscilloscope is the most important
measuring instrument for the characterization of sig­
nals in the time domain. HAMEG Instruments offers
the most comprehensive portfolio for the diverse areas
of application in industry, handcraft, science, educa­
tion, training, and service as well as the private sector.
In addition to our innovative DSO’s (Digital Storage
Oscilloscopes) and MSO’s (Mixed Signal Oscilloscopes)
the purely Analog Oscilloscope HM400 with the clas­
sical CRT (Cathode Ray Tube) are for the customers
choice.
The demand for purely analog instruments has been
diminishing for some time because DSO’s offer a host
of advantages such as documentation, the ability to
extensively analyze data, a compact package etc. MSO’s
(Mixed-Signal Oscilloscopes) additionally allow the
simultaneous display of analog and digital signals on
several channels.
Modern electronic gear, as a rule, contains micro­
processors, FPGA’s, serial interfaces such as I2C,
SPI or UART. The HMO series oscilloscopes, with the
available options, feature triggering and decoding of
these bus protocols in real time, which is very help­
ful and time-saving for debugging during the design
phase. Modern semiconductor technologies generate
signals with rise times of a few ns and thus demand
higher bandwidths and sampling rates in order to mini­
mize the measurement errors. The high sampling rate
requires a deeper memory in order to acquire a given
time window. HAMEG Instruments always offers a well
balanced set of these three specifications in order to
display a correct measurement result even in criti­
cal cases. Last but not least our experience of 50 plus
years in oscilloscope technology stands for first-class
trigger performance, extraordinary sensitivity, lownoise A/D converters, unexcelled longevity, and an
excellent price/performance ratio.
5
Oscilloscopes
HMO3524
350MHz 2[4] Channel Digital Oscilloscope
HMO3522 [HMO3524]
8 Channel Logic Probe
HO3508
Carrying Case HZ99
Active Probe HZO30
R4 GSa/s Real Time, 50 GSa/s Random Sampling,
Low Noise Flash A/D Converter (Reference Class)
R 4 MPts Memory, Memory
oom up to 100,000:1
R MSO (Mixed Signal Opt. HO3508 [HO3516])
with 8 [16] Logic Channels
RSerial Bus Trigger and Hardware accelerated Decode,
I2C, SPI, UART/RS-232 (Opt. HOO10, HOO11), CAN/LIN (Opt. HOO12)
R 8 User definable Markers for easy Navigation
R Pass/Fail Test based on Masks
R Vertical Sensitivity 1 mV/div., Offset Control ±0.2...±20 V
R12 div. x-Axis Display Range, 20 div. y-Axis Display Range
(VirtualScreen)
R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
R6 Digit Counter, Automeasurement, Formula Editor, Ratiocursor,
FFT for Spectral Analysis
R Crisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
R Lowest Noise Fan
R3 x USB for Mass Storage, Printer and Remote Control
optional IEEE-488 (GPIB) or Ethernet/USB
6
See page 70 for technical specifications or www.hameg.com/HMO3522 [www.hameg.com/HMO3524]
Oscilloscopes
HMO2524
250MHz 4 Channel Digital Oscilloscope
HMO2524
Mask Test
R 2.5 GSa/s Real Time, 25 GSa/s Random Sampling,
Low Noise Flash A/D Converter (Reference Class)
R 4 MPts Memory, Memory
oom up to 100,000:1
RMSO (Mixed Signal Opt. HO3508 [HO3516])
with 8 [16] Logic Channels
RSerial Bus Trigger and Hardware accelerated Decode,
I2C, SPI, UART/RS-232 (Opt. HOO10, HOO11), CAN/LIN (Opt. HOO12)
R 8 User definable Markers for easy Navigation
R Pass/Fail Test based on Masks
R Vertical Sensitivity 1 mV/div., Offset Control ±0.2...±20 V
R12 div. x-Axis Display Range, 20 div. y-Axis Display Range
(VirtualScreen)
R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
R6 Digit Counter, Automeasurement, Formula Editor, Ratiocursor,
FFT for Spectral Analysis
R Crisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
R Lowest Noise Fan
R3 x USB for Mass Storage, Printer and Remote Control
optional IEEE-488 (GPIB) or Ethernet/USB
Passive Probe 1000:1
HZO20
AC/DC Current Probe
100/1000 A HZO51
See page 69 for technical specifications or www.hameg.com/HMO2524
7
Oscilloscopes
150MHz/200MHz 2[4] Channel
Digital Oscilloscope
HMO1522 [HMO1524]/HMO2022 [HMO2024 ]
HMO2024
NEW
2 Channel Version
HMO2022
Side view
8 Channel Logic Probe
HO3508
R2 GSa/s Real Time, Low Noise Flash A/D Converter
(Reference Class)
R 2 MPts Memory, Memory
oom up to 50,000:1
R MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
RSerial Bus Trigger and Hardware accelerated Decode,
I2C, SPI, UART/RS-232 (Opt. HOO10, HOO11), CAN/LIN (Opt. HOO12)
R 8 User definable Markers for easy Navigation
R Pass/Fail Test based on Masks
R Vertical Sensitivity 1 mV/div., Offset Control ±0.2...±20 V
R12 div. x-Axis Display Range, 20 div. y-Axis Display Range
(VirtualScreen)
R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
RComponent Tester, 6 Digit Counter, Automeasurement,
Formula Editor, Ratiocursor, FFT for Spectral Analysis
RCrisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
R Lowest Noise Fan
R3 x USB for Mass Storage, Printer and Remote Control
optional IEEE-488 (GPIB) or Ethernet/USB
8
ee page 65 for technical specifications or www.hameg.com/HMO1522 [www.hameg.com/HMO1524]
S
See page 67 for technical specifications or www.hameg.com/HMO2022 [www.hameg.com/HMO2024]
Oscilloscopes
70MHz/100MHz 2[4] Channel
Digital Oscilloscope
HMO722 [HMO724]/HMO1022 [HMO1024]
HMO1024
NEW
Carrying Case HZO90
R2 GSa/s Real Time, Low Noise Flash A/D Converter
(Reference Class)
R 2 MPts Memory, Memory
oom up to 50,000:1
R MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
RSerial Bus Trigger and Hardware accelerated Decode,
I2C, SPI, UART/RS-232 (Opt. HOO10, HOO11), CAN/LIN (Opt. HOO12)
R 8 User definable Markers for easy Navigation
R Pass/Fail Test based on Masks
R Vertical Sensitivity 1 mV/div.
R12 div. x-Axis Display Range, 20 div. y-Axis Display Range
(VirtualScreen)
R Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
RComponent Tester, 6 Digit Counter, Automeasurement,
Formula Editor, Ratiocursor, FFT for Spectral Analysis
RCrisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
R Lowest Noise Fan
R3 x USB for Mass Storage, Printer and Remote Control
optional IEEE-488 (GPIB) or Ethernet/USB
Component Tester/Bus
Signal Source
Ethernet/USB-Interface
HO730 (Option)
See page 62 for technical specifications or www.hameg.com/HMO722 [www.hameg.com/HMO724]
See page 64 for technical specifications or www.hameg.com/HMO1022 [www.hameg.com/HMO1024]
9
Oscilloscopes
HOO10
HOO10/HOO11 Serial Bus
for all Oscilloscopes of the HMO Series
Mixed Signal and Bus Display
SPI Bus Trigger Setup
I2C Bus Hex decoding on the Analog Channel
I2C Bus ASCII and Binary
RHOO10 via Analog Channels and/or Logic Channels, HOO11 via Analog Channels
R I2C, SPI, UART/RS-232 Bus Trigger and Decode
R Hardware accelerated Decode in Realtime
CAN/LIN
See Page 90
R Color Coded Display of the Content for intuitive ­Analysis and easy Overview
R More Details of the decoded Values become visible with ­increasing Zoom Factor
R Bus Display with synchronous Display of the Data and maybe Clock Signal
R Decode into ASCII, Binary, Hexadecimal or Decimal Format
R Up to four Lines to comfortably show the decoded Values
R Powerful Trigger to isolate specific Messages
R Option for all Oscilloscopes of the HMO Series, retrofittable
See page 89 for technical specifications or www.hameg.com/HOO10
10
Oscilloscopes
HM400
40MHz Analog Oscilloscope
HM400
No Signal Distortion
­resulting from Overshoot
R Reference-Class in Sensitivity and Input Voltage Range
R2 Channels with Deflection Coefficients 1 mV/div.…20 V/div.,
variable up to 50 V/div.
RTime Base 100 ns/div.…0.2 s/div.,
with X Magnification to 10 ns/div.
RLow Noise Measuring Amplifiers with high Pulse Fidelity
and minimum Overshoot
Line triggered composite
Video Signal
RPeak to Peak Trigger for stable Triggering 0…50 MHz
at 0.5 div. Signal Level (up to 80 MHz at 1 div.)
R Autoset, Save/Recall Memories for 6 Instrument Settings
R Yt- and XY-Mode with Z-Input for Intensity Modulation
RComponent Characterisation with Component Tester
(two Terminal Network Measurement)
Characteristic of a Z-Diode
with Component Test Mode
R Low Power Consumption, no Fan
See page 62 for technical specifications or www.hameg.com/HM400
11
Spectrum Analysis
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
12
Spectrum Analysis
HAMEG
Spectrum Analysis
Change of paradigms in measurement technology
With the introduction of the modern HMS series spec­
trum analyzers, HAMEG started a change of paradigms
in the design lab. Until a short time ago, this meas­
urement technology was unaffordable for most users.
HAMEG Instruments puts an end to this exclusivity by
offering the HMS series – according to its tradition of
delivering high performance measurement technology
at a fair price. During the design, a practically oriented
concept of instrument operation took highest priority so
that the user can forget about the complex theory behind
spectrum analysis. The increasing wide-spread use of
wireless applications as well as the requirement for
minimizing electromagnetic emissions from high per­
formance digital systems caused a change of approach
in design labs and test sites. While signal analysis in the
time domain is well established, spectrum analysis is
now starting to find its place on the lab bench.
The scope of applications of a spectrum analyzer in R & D,
test sites, service and EMI testing is wide. Spectrum
analyzers can display signals up into the GHz range.
By employing the superhet receiver principle and using
logarithmic signal processing and a logarithmically
scaled display, their sensitivity exceeds that of oscil­
loscopes by more than 3 orders of magnitude and the
dynamic range is markedly larger (>80 dB).
Caution – the sensitive measuring input is 50 ohms and
easily destroyed! (Observe the maximum input power
whenever measuring higher power signals!) It is hence
recommended, whenever analysing unknown signals, to
provide protective measures, e.g. to insert an attenua­
tor of sufficient power rating at the input. When meas­
uring signals with spectrum analyzers in the frequency
domain, the phase information is lost, but in many prac­
tical applications this information is not required.
Spectrum analysis with HAMEG spectrum analyzers
features a frequency range of up to 3 GHz and a large
dynamic range; for transmission measurements instru­
ments with a tracking generator are available which are
easy to operate. Integrated interfaces for fast data com­
munication with an external pc including free software
for EMI pre-compliance test measurement functions, as
well as the availability of a vast range of optional acces­
sories (e.g. near-field probes for diverse measurements)
promote HAMEG spectrum analyzers to be the „ideal
partners“ for a variety of applications including EMI tests
and measurements on wireless systems such as UMTS,
GSM, TETRA, DBV-T, Bluetooth, WLAN etc, ...
13
Spectrum Analysis
HMS3010
1GHz [3GHz] Spectrum Analyzer
HMS1000 [HMS3000]
1 GHz Spectrum Analyzer
HMS1000 without TG
R Frequency Range 100 kHz…1 GHz [3 GHz]
R Tracking Generator HMS1010 [HMS3010] -20…0 dBm
RAmplitude Measurement Range -114…+20 dBm
DANL -135 dBm with Preamp. Option HO3011
R Sweep Time 20 ms…1000s
3 GHz EMI Near Field Probe
Set HZ550L
RResolution Bandwidth 100 Hz…1 MHz in 1–3 Steps,
200 kHz (-3 dB); additional 200 Hz, 9 kHz, 120 kHz, 1 MHz (-6 dB)
R Spectral Purity <-100 dBc/Hz (@100 kHz)
R Video Bandwidth 10 Hz…1 MHz in 1–3 Steps
R Integrated AM and FM Demodulators (Phone and int. Speaker)
R Detectors: Auto-, Min-, Max-Peak, Sample, RMS, Quasi-Peak
VSWR Test Unit HZ547
R 8 Markers with Delta Marker, miscellaneous Peak Functions
R Crisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
R3 x USB for Mass-Storage, Printer and Remote Control
optional IEEE-488 (GPIB) or Ethernet/USB Interface
14
See page 73 for technical specifications or www.hameg.com/HMS1010 [www.hameg.com/HMS3010]
Spectrum Analysis
1GHz Spectrum Analyzer
HMS1000E
HMS1000E
NEW
Comfortable automatic
measurement functions
with up to 8 markers
R Frequency Range 100 kHz…1 GHz
R Amplitude Measurement Range -104…+20 dBm
R Sweep Time 20 ms…1000s
RResolution Bandwidth 10 kHz…1 MHz in 1–3 Steps,
200 kHz (-3 dB)
R Spectral Purity <-100 dBc/Hz (@100 kHz)
1 GHz EMI Near Field Probe
Set HZ530
R Video Bandwidth 1 kHz…1 MHz in 1–3 Steps
R Integrated AM and FM Demodulator (Phone and int. Speaker)
R Detectors: Auto-, Min-, Max-Peak, Sample, RMS
R 8 Marker with Delta Marker, miscellaneous Peak Functions
R Crisp 16.5 cm (6.5”) TFT VGA Display
R3 x USB for Mass-Storage, Printer and Remote Control,
optional IEEE-488 (GPIB) or Ethernet/USB Interface
Ethernet/USB-interface
HO730 (Option)
See page 72 for technical specifications or www.hameg.com/HMS1000E
15
Spectrum Analysis
Absolut Marker M1; Delta Marker D2; Noise Marker N3
Preamplifier Option HO3010 for HMS1000, HMS1010, HMS3000, HMS3010
(Licence Key)
Pre-Compliance Software (HMExplorer)
R
Screenshot of the free Pre-Compliance EMI PC Software
(not available for HMS1000E)
16
Spectrum Analysis/Accessories
HM6050-2
Line Impedance Stabilization Network
HM6050-2
RMeasurement of Line-conducted Interference
within the Range from 9 kHz…30 MHz (CISPR 16)
R Selectable Transient Limiter
R Artificial Hand Connector
Technical Specifications at 23 °C ±2 °C
Max. Current:
Line Voltage/Frequency:
Artificial Hand:
PE (selectable):
9 kHz…30 MHz
Z = 50 Ω || (50 µH + 5 Ω),
Error <20 % under terms of VDE 876T1
16 A
230 V/50…60 Hz, CAT II
220 pF + 511 Ω
50 µH || 50 Ω
Transient Limiter
Frequency Range:
Transmission Loss:
150 kHz…30 MHz
10 dB (+1.5/-0.5 dB)
Connectors
Measurement Output:
Power Supply Socket for DUT:
Artificial Hand:
Line Cord
50 Ω BNC
Standard German (UK, US) wall outlets
4 mm banana socket
fixed
Frequency Range:
Impedance Characteristics:
Miscellaneous
Operating Temperature:
Power Supply:
Safety Class:
Dimensions and Weight:
HM6050-2K
(UK Version, 230 V)
HM6050-2S
(US Version, 115 V)
Measurement
of Line-conducted
Interference: Fail
Measurement
of Line-conducted
Interference: Pass
10…40 °C
HM6050-2D (DE Version) 230 V ±10 %, 50…60 Hz
HM6050-2K (UK Version) 230 V ±10 %, 50…60 Hz
HM6050-2S (US Version) 115 V ±10 %, 50…60 Hz
Safety class I (IEC1010-1/VDE 0411)
285 x 125 x 380 mm (W x H x D), approx. 6 kg
17
EMI-measurement tools
HZ540/HZ550 EMV Near-Field Probe Set up to 3GHz
HZ540 and HZ550 EMI-Near Field Probe Sets
The HZ540/550 are the ideal toolkits for the investiga­
tion of RF electromagnetic fields. They are indispen­
sable for EMI pre-compliance testing during product
development, prior to third party testing. The sets
include 3 or 5 hand-held probes with built-in preamplifier covering the frequency range from <1 MHz
to approx. 3000 MHz.
HZ550
The probes of the basic set HZ540 include one mag­
netic field probe, one electric field probe, and a high
impedance probe. In addition to the HZ550 features an
optional µ-magnetic field probe and an antenna. All
probe outputs are matched to the 50 Ω inputs of spect­
rum analyzers or RF-receivers.
Picture
HZ550L
Probe Set HZ540 (Basic Set)
HZ551
Frequency range:
Directional sensitivity:
Output impedance:
Power supply:
HZ552
Frequency range:
Directional sensitivity:
Output impedance:
Power supply:
HZ553
Frequency range:
Input capacity:
Attenuation:
Max. input voltage:
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Physical dimensions:
HZ540 consists of:
18
Probe Set HZ550
Electrical Field Probe
<1 MHz to approx. 3 GHz
omnidirectional
Sensitive to electrical fields
50 Ω; SMA-connector
6 Vdc /80 mA
(directly from HAMEG Spectrum
Analyzer)
HZ554
Frequency range:
Directional sensitivity:
Magnetic Field Probe
<30 MHz to approx. 3 GHz
similar to a frame antenna
Sensitive to changing magnetic fields
50 Ω; SMA-connector
6 Vdc /50 mA
(directly from HAMEG Spectrum
Analyzer)
HZ556
Frequency range:
Directional pattern:
High Impedance Probe
<1 MHz to approx. 3 GHz
<2 pF II approx. 250 kΩ
between 10:1 and 30:1
10 Vpp (without significant distortion)
30 V
50 Ω; SMA-connector
6 Vdc /80 mA
(directly from HAMEG Spectrum
Analyzer)
13 x 27 x 70 mm (W x H x D)
(+ antenna at HZ551)
HZ551 Electrical Field Probe
HZ552 Magnetic Field Probe
HZ553 High Impedance Probe
1 SMA to N-Cable 1.2 m
Case
Manual
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Max. input power:
Output impedance:
Power supply:
Physical dimensions:
HZ550 consists of:
Magnetic Field Probe (small sensor)
<50 MHz to approx. 3 GHz
Sensitive to chan­ging magnetic fields
High spatial re­so­lution due to very
small sensor area
30 V
50 Ω; SMA-connector
6 Vdc /50 mA
Active antenna
<30 MHz to approx. 3 GHz
like a frame antenna
Radiation of changing magnetic fields
0.5 W (short term)
50 Ω; SMA-connector
not required; passive probe
13 x 27 x 70 mm (W x H x D)
(+ antenna at HZ551)
1 HZ540 Basic Set
1 HZ554 Magnetic Field Probe
1 HZ556 Active antenna
1 SMA to N-Cable 1.2 m
Probe Set HZ540L and HZ550L
HZ540L = HZ540 (without HZ553) + HZ555 Low Capacitance Probe
HZ550L = HZ550 (without HZ553) + HZ555 Low Capacitance Probe
HZ555
Frequency range:
Input impedance:
Attenuation:
Max. input voltage:
Max. voltage of a
non-insulated conductor:
Output impedance:
Power supply:
Low Capacitance Probe
approx. 400 kHz…3 GHz
<0.2 pF // 250 kΩ
10:1
5 Vpp
30 V
50 Ω; SMA-connector
6 Vdc /80 mA
EMI-measurement tools
HZ530 EMV Near-Field Probe Set up to 1GHz
Typical frequency response H-field probe
Typical frequency response high-impedance probe
Technical specifications at 23 °C ±2 °C
Frequency Range:
Supply Voltage:
Supply Current:
Probe Dimensions:
Cases:
Set includes:
100 kHz…1 GHz
6 Vdc from Spectrum
Analyzer or batteries,
4 x Mignon/AA,
not included
approx. 10…24 mAdc
40 x 90 x 195 mm (W x H x D)
plastic,
internal electrical shielding
1 E-field probe
1 H-field probe
1 high-impedance probe
1 BNC cable 1.5 m
1 power cable
Operator’s Manual
Robust carrying case
HZ530
Typical frequency response E-field probe
The HZ530 Probe Set consists of three active broad­
band probes for EMI diagnosis. The probes are
­designed for connection to a HAMEG spectrum ana­
lyzer with input impedance of 50 Ω. The probes can be
powered by the spectrum analyzer or batteries. The
slim format ensures easy access to the test object
even in cramped test environments.
The H-field probe provides a signal that is propor­
tional to the magnetic field strength to the spectrum
analyzer. This makes it possible to localize sources of
interference with relatively high precision.
The high-impedance probe can be used to determine
interference levels on contacts, lines and printed cir­
cuit boards.
The E-field probe is the most sensitive of the three
probes. It can be used to assess the total effect of
shielding and filtering in a tested unit.
19
Power Supplies
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
20
Power Supplies
HAMEG
Power Supplies
Keeping things simple – One for All
The power supplies market is highly partitioned. The
user is faced with a seemingly unlimited number of
models with diverse specifications, the result being the
accumulation of a whole assembly of power supplies in
the design lab or test site, the better part of which are
rarely used.
HAMEG Instruments’ two types of power supplies
(HM8143 and HMP4040) cover numerous applications;
each type excels by being universally applicable, sim­
ple to operate, its compactness, and an unexcelled
price/performance ratio. Test sites especially value this
advantage because universal instruments minimize setup times. The power supply portfolio consists in total of
6 types in order to also care for smaller budgets.
In the HMP series there are two 200 W and two 400 W
types available which cover the range of 0...32 V and up
to 10 A, depending on the number of channels required.
This series is based on a classical concept with a mains
transformer, high efficiency electronic pre regula­
tors and linear post regulators. This concept yields the
high power in the smallest space with the highest effi­
ciency. The HMP series further excels by its intelli­
gent power management which allows higher currents
(e.g. up to 10 A) at medium voltages (e.g. up to 16 V) to
be made available. Excellent low residual ripple volt­
ages (150 µVrms) are realized even at full power output.
The high adjustment and back-reading resolution of up
to 1 mV/0.1 mA fulfills even the strictest requirements.
Last but not least there is the EasyArb function availa­
ble on all channels which allows you to program simple
arbitrary voltage and current waveforms.
The HM8143 resides in the 130 W class and is unique in
its class with its two 0...32 V/2 A two-quadrant outputs
which can operate as source and sink outputs. It also
features an arbitrary function, and its output voltage
may be modulated via an external input. In the past 20
years, literally thousands of users, predominately in test
sites, used this type and its predecessor, the HM8142,
taking advantage of its flexibility to realize numerous
applications.
The HM7042-5 with 2 x 0...32 V/2 A and 0...5.5 V/5 A is our
best selling power supply for many years and became
indispensable in many labs.
All power supplies feature galvanically isolated float­
ing overload and short-circuit proof outputs and may be
connected in series or in parallel, thus making very high
currents and voltages available. A precondition is the
common electronic fuse which disconnects all channels
simultaneously in case of a fault. The HMP series also
provides an extended FuseLink system which allows
individual logic combinations.
21
Power Supplies
HMP4040
Programmable 3[4] Channel
High-Performance Power Supply
HMP4030 [HMP4040]
3 Channel Version
HMP4030
R3 x 0…32 V/0…10 A
[4 x0…32 V/0…10 A
384 W max.
384 W max.]
R 384 W Output Power realized by intelligent Power Management
R Low Residual Ripple: <150 µVrms due to linear Post Regulators
R High Setting- and Read-Back Resolution of 1 mV up to 0.2 mA
Individual Linking of single
Channels using FuseLink
R Keypad for direct Parameter Entry
RGalvanically isolated, earth-free and short circuit protected
­Output Channels
R Advanced Parallel- and Serial Operation via V/I Tracking
R EasyArb Function for free definable V/I Characteristics
R FuseLink: Individual Channel Combination of Electronic Fuses
Rear Outputs for simple
Integration in Rack Systems
R Free adjustable Overvoltage Protection (OVP) for all Outputs
R All Parameters clearly displayed via LCD/Illuminated Buttons
R Rear Connectors for all Channels including Sense
R USB/RS-232 Interface, optional Ethernet/USB or IEEE-488 (GPIB)
22
See page 76 for technical specifications or www.hameg.com/HMP4030 [www.hameg.com/HMP4040]
Power Supplies
HMP2030
Programmable 2[3] Channel
High-Performance Power Supply
HMP2020 [HMP2030]
2 Channel Version
HMP2020
R1 x 0…32 V/0…10 A
[3 x0…32 V/0…5 A
1 x 0…32 V/0…5 A
188 W max.]
188 W max.
R 188 W Output Power realized by intelligent Power Management
R Low Residual Ripple: <150 µVrms due to linear Post Regulators
R High Setting- and Read-Back Resolution of 1 mV up to 0.1 mA
RGalvanically isolated, earth-free and short circuit protected
Output Channels
Individual Linking of single
Channels using FuseLink
R Advanced Parallel- and Serial Operation via V/I Tracking
R EasyArb Function for free definable V/I Characteristics
R FuseLink: Individual Channel Combination of Electronic Fuses
R Free adjustable Overvoltage Protection (OVP) for all Outputs
R All Parameters clearly displayed via LCD/Illuminated Buttons
R Rear Connectors for all Channels including Sense
Rear Outputs for simple
Integration in Rack Systems
R USB/RS-232 Interface, optional Ethernet/USB or IEEE-488 (GPIB)
See page 75 for technical specifications or www.hameg.com/HMP2020 [www.hameg.com/HMP2030]
23
Power Supplies
HM7042-5
Triple Power Supply
HM7042-5
R 2 x 0…32 V/0…2 A
1 x 0…5.5 V/0…5 A
R High-Performance and inexpensive Laboratory Power Supply
R Floating, overload and short-circuit proof Outputs
RSeparate Voltage and Current Displays for each Output
4 Digits at Channel 1+3; 3 Digits at Channel 2
HZ42 19“ Rackmount Kit
2RU
RDisplay Resolution:
10 mV/1 mA at Channel 1+3; 10 mV/10 mA at Channel 2
R Protection of sensitive Loads by Current Limit or Electronic Fuse
R Pushbutton for activating/deactivating all Outputs
R Low Residual Ripple, high Output Power, very good Regulation
R Parallel (up to 9 A) and Series (up to 69.5 V) Operation
R Temperature-controlled Fan
Silicone Test Cable HZ10S
24
See page 74 for technical specifications or www.hameg.com/HM7042
Power Supplies
HM8143
Arbitrary Power Supply
HM8143
AF Arbitrary Signal
R 2 x 0…30 V/0…2 A
1 x 5 V/0…2 A
R Display Resolution 10 mV/1 mA
R Parallel (up to 6 A) and Series (up to 65 V) Operation
R Electronic Load up to 60 W per Channel (max. 2 A)
RArbitrary Waveform Power Supply (4096 Points, 12 Bit):
Creation of customized Waveforms
RSoftware for Remote Control and for Creation of Arbitrary
Waveforms
HO880 IEEE-488 (GPIB)
Interface (Option)
R Electronic Fuse and Tracking Mode for 30 V Outputs
RExternal Modulation of Output Voltages:
Input Voltage 0…10 V, Bandwidth 50 kHz
RSENSE Lines for Compensation of the Voltage drop across
the Cables
HZ42 19“ Rackmount Kit
2RU
R Multimeter Mode for all adjustable Outputs
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
See page 74 for technical specifications or www.hameg.com/HM8143
25
Programmable Measuring Instruments Series 8100
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring
Instruments Series 8100
Modular System Series 8000
Options
Accessories
Specifications
26
Programmable Measuring Instruments Series 8100
HAMEG
Programmable
Measuring Instruments
Series 8100
HAMEG Programmable Measuring Instruments Series 8100…
…are ideally suited for test installations in produc­
tion and automated tests in laboratories. They support
either an USB/RS-232, or an IEEE-488 (GPIB) interface
and thus may be easily integrated in any test system. In
combination with other HAMEG remote controlled instru­
ments high performance test systems may be easily and
cost effectively set up. Of course, any of these instruments
can be operated manually and used in laboratories.
The 6½ Digit Precision Multimeter HM8112-3, the 8 kW
Power Meter HM8115-2, the LCR Bridge HM8118,
the 3 GHz Universal Counter HM8123 as well as the
new 25 MHz and 50 MHz Arbitrary Function Generators
Series HMF are high performance precision measur­
ing instruments for research and development labs,
industry, universities, test and production facilities as
well as for service. The RF signal generators HM8134-3
and HM8135 are high precision synthesizers with a fre­
quency range of 1 Hz to 1.2 GHz respectively 3 GHz. The
12.5 MHz Function Generator HM8150 uses direct digital
frequency synthesis (DDS) for the generation of stable
low distortion signals and guarantees optimum per­
formance.
27
Programmable Measuring Instruments Series 8100
HMF2550
25MHz [50MHz] Arbitrary
Function Generator
HMF2525 [HMF2550]
Generation of complex
Waveforms with 256 kPts
in 14 Bit
All Parameters at a glance
on the 3.5“ TFT and
interactive Softkeys
Ethernet/USB-Interface
HO730 (Option)
R Frequency Range 10 µHz…25 MHz [50 MHz]
R Output Voltage 5 mVpp…10 Vpp (into 50 Ω) DC Offset ±5 mV…5 V
R Arbitrary Waveform Generator: 250 MSa/s, 14 Bit, 256 kPts
RSine, Square, Pulse, Triangle, Ramp, Arbitrary Waveforms
incl. Standard Curves (white Noise, Cardiac etc.)
R Total harmonic Distortion 0.04 % (f <100 kHz)
R Burst, Sweep, Gating, external Trigger
R Rise Time <8 ns, in Pulse Mode 8…500 ns Variable-Edge-Time
RPulse Mode: Frequency Range 100 µHz…12.5 MHz [25 MHz],
Pulse Width 15 ns…999 s, Resolution 5 ns
R Modulation Modes AM, FM, PM, PWM, FSK (int. and ext.)
R 10 MHz Timebase: ±1 ppm TCXO, rear I/O BNC Connector
R Front USB Connector: Save and Recall of Waveforms and Settings
R8.9 cm (3.5“) TFT: crisp Representation of the Waveform
and all Parameters
RUSB/RS-232 Dual-Interface, optional Ethernet/USB
or IEEE-488 (GPIB)
28
See page 83 for technical specifications or www.hameg.com/HMF2525 [www.hameg.com/HMF2550]
Programmable Measuring Instruments Series 8100
HM8112-3
6½-Digit Precision Multimeter
HM8112-3
HM8112-3S:
Multimeter with built-in
Scanner Card (8+1
Channels, 2- and 4-Wire)
R 6½-Digit Display (1,200,000 Counts)
R Resolution: 100 nV, 100 pA, 100 µΩ, 0.01 °C/F
R DC Basic Accuracy 0.003 %
R 2-Wire/4-Wire Measurements
R Measurement Intervals adjustable from 0.1…60 s
R Up to 100 Measurements per Second transmitted to a PC
R True RMS Measurement, AC and DC+AC
RMathematic Functions: Limit Testing, Minimum/Maximum,
Average and Offset
RTemperature Measurements with Platinum (PT100/PT1000)
and Ni (K and J types) Sensors
R Internal Data Logger for up to 32,000 Measurement Results
R Offset Correction
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
R Optional: Scanner Card (8+1 Channels each 2- and 4-Wire)
HZ42 19“ Rackmount Kit
2RU
Precise Temperature
Measurement with Sensor
See page 76 for technical specifications or www.hameg.com/HM8112
29
Programmable Measuring Instruments Series 8100
HM8115-2
8kW Power Meter
HM8115-2
HZ815 Power Adapter
R Wide Measurement Range 1 mW…8 kW
R Voltage Range 100 mV…500 V, Current Range 1 mA…16 A
R Frequency Range DC…1 kHz
R Simultaneous Voltage, Current and Power Display
R Display of apparent, active and reactive Power
RMS Value
R Power Factor Display
R Autoranging, simple Operation
RMonitor Output (BNC) representing the instantaneous Power
R Suitable for Measurements on Frequency Converters
R Software for Remote Control and Data Acquisition included
Active Power
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
30
See page 77 for technical specifications or www.hameg.com/HM8115
Programmable Measuring Instruments Series 8100
HM8118
200kHz LCR-Bridge
HM8118
HZ188 4-Wire SMD
Test Fixture
(included in Delivery)
R Basic Accuracy 0.05 %
R Measurement Functions L, C, R, |Z|, X, |Y|, G, B, D, Q, Θ, ∆, M, N
R Test Frequencies 20 Hz…200 kHz
R Up to 12 Measurements per Second
R Parallel and Series Mode
RBinning Interface HO118 (optional) for automatic Sorting
of Components
HZ184 Kelvin Clip Leads
(included in Delivery)
R Internal programmable Voltage and Current Bias
R Transformer Parameter Measurement
R External Capacitor Bias up to 40 V
R Kelvin Cable and 4-Wire SMD Test Adapter included in Delivery
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
HZ181 4-Wire Test Fixture
with Shorting Plate
­(optional)
See page 78 for technical specifications or www.hameg.com/HM8118
31
Programmable Measuring Instruments Series 8100
HM8123
3GHz Programmable Counter
HM8123
HZ33, HZ34
Test Cable BNC/BNC
R Measurement Range 0 Hz…3 GHz
R2 Measurement Inputs DC…200 MHz,
1 Measurement Input 100 MHz…3 GHz
RInput Impedance A/B: 1 MΩ/50 Ω (switchable), Sensitivity 25 mVrms
R Input Impedance C: 50 Ω, Sensitivity 30 mVrms
HZ42 19“ Rackmount Kit
2RU
R 400 MHz Time Base with 0.5 ppm Stability
R 10-Digit Resolution at 10 s Gate Time
R 9 Measurement Functions, external Gate and Arming
R Input for external Time Base (10 MHz)
HZ20 Connector BNC to
4 mm Socket
RStandard: TCXO (Temperature Stability: ±0.5 x 10-6)
Optional: OCXO (Temperature Stability: ±1 x 10-8)
RIntuitive One-Pushbutton Operation each Function directly
addressable
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
32
See page 79 for technical specifications or www.hameg.com/HM8123
Programmable Measuring Instruments Series 8100
HM8134-3
1.2 G H z R F - S y n t h e s i z e r
HM8134-3
R Frequency Range 1 Hz…1.2 GHz
R Output Power -127…+13 dBm
R Frequency Resolution 1 Hz (Accuracy 0.5 ppm)
R Input for external Time Base (10 MHz)
R Modulation Modes: AM, FM, Pulse, Φ, FSK, PSK
R Rapid Pulse Modulation: typ. 200 ns
HZ42 19“ Rackmount Kit
2RU
RInternal Modulator (Sine Wave, Square Wave, Triangle, Sawtooth)
10 Hz…150 kHz
R High spectral Purity
R 10 Configuration Memories including Turn-On Configuration
RStandard: TCXO (Temperature Stability: ±0.5 x 10-6)
Optional: OCXO (Temperature Stability: ±1 x 10-8)
HO880 IEEE-488 (GPIB)
Interface (Option)
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
See page 80 for technical specifications or www.hameg.com/HM8134
33
Programmable Measuring Instruments Series 8100
HM8135
3GHz RF-Synthesizer
HM8135
R Frequency Range 1 Hz…3 GHz
R Output Power -135…+13 dBm
R Frequency Resolution 1 Hz (Accuracy 0.5 ppm)
R Input for external Time Base (10 MHz)
HO880 IEEE-488 (GPIB)
Interface (Option)
R Modulation Modes: AM, FM, Pulse, Φ, FSK, PSK
R Rapid Pulse Modulation: typ. 200 ns
RInternal Modulator (Sine Wave, Square Wave, Triangle, Sawtooth)
10 Hz…200 kHz
R High spectral Purity
R 10 Configuration Memories including Turn-On Configuration
Internal Modulation Source
RStandard: TCXO (Temperature Stability: ±0.5 x 10-6)
Optional: OCXO (Temperature Stability: ±1 x 10-8)
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
34
See page 81 for technical specifications or www.hameg.com/HM8135
Programmable Measuring Instruments Series 8100
HM8150
12.5MHz Arbitrary Function Generator
HM8150
Gated Sine Wave,
PC-Software included
R Frequency Range 10 MHz…12.5 MHz
R Output Voltage 10 mVpp…10 Vpp (into 50 Ω)
RWaveforms: Sine Wave, Square Wave, Triangle, Pulse,
Sawtooth, Arbitrary
R Rise and Fall Time <10 ns
R Pulse width Adjustment: 100 ns…80 s
Amplitude-­modulated
Sine Wave
R Arbitrary Waveform Generator 40 MSa/s
R Burst, Gating, External Triggering, Sweep
RSoftware for Remote Control and for Creation of
Arbitrary Waveforms
R External Amplitude Modulation (Bandwidth 20 kHz)
RIntuitive Operation with one touch of a Button –
quick Change of Signals
Triggered Arbitrary Signal
RGalvanically isolated USB/RS-232 Interface,
optional IEEE-488 (GPIB)
See page 82 for technical specifications or www.hameg.com/HM8150
35
Modular System Series 8000
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
36
Modular System Series 8000
HAMEG
Modular System Series 8000
In many years of practical application…
…the HAMEG Modular System Series 8000 has proven
its value to the customer. The advantages of this
Modular System have been demonstrated by several
100,000 modules sold. The unexcelled price-perform­
ance ratio and the enormous flexibility of the plug-in
system allow you to adapt your measurement setups
quickly and cost effectively to changing requirements.
You save space by stacking up to 5 instruments. This will
offer you 10 instruments in a minimum of space. The top
covers of the instruments feature receptacles for the
feet of the instrument above. The mainframes thus can­
not move and may also be stacked together with other
HAMEG ins­truments like power supplies, spectrum
analyzers and oscilloscopes.
The blank module HM800 is available for your own
designs to be integrated with the other measuring
instruments. The power supply voltages necessary are
availab­le from the mainframe. Especially for schools and
training centers the Modular System Series 8000 offers
a cost effective flexible alternative to conventional meas­
uring equipments. As the mainframe HM8001-2 allows
the simultaneous operation of two modules in any com­
bination most often a single such basic unit will be all
that is needed for a student in a laboratory. The modules
necessary will be issued to the students depending on
the requirements of the specific exercise.
The Modular System Series 8000 offers, in addition to
the mainframe HM8001-2 and the blank module HM800,
the 4¾-Digit Programmable Multimeter HM8012, the
25 kHz LCR-Meter HM8018, the 1.6 GHz Universal
Counter HM8021-4, the 10 MHz Function Generator
HM8030-6 and the Triple Power Supply HM8040-3.
37
Modular System Series 8000
HM8001-2
Mainframe
HM8001-2
The Mainframe is supplied without the Modules shown in the Illustration
Modular System
R Basic Unit for Modules of the Modular System Series 8000
R Power Supply for 2 Modules
RDC Voltages electronically regulated,
floating and short-circuit proof
HM8001-2 Mainframes
can be stacked up to
5 Units high
R Power Transformer with thermal Fuse
R Up to 5 Mainframes can be stacked
RModule HM800 for customized Instrument Construction
available
R4 BNC Connectors on the Rear Panel of the HM8001-2
(Option HO801) provide for Signal Transmission to
or from HM8021-4 and HM8030-6 Modules
Option HO801 – 4 BNC
­Connectors on Rear Panel
38
See page 84 for technical specifications or www.hameg.com/HM8001
Modular System Series 8000
4¾-Digit Programmable Multimeter
HM8012
WDM8012 Software
(included)
R 4¾-Digit Display with 50,000 Counts
R Basic Accuracy 0.05 %
R Max. Resolution: 10 µV, 0.01 dBm, 10 nA, 10 mΩ, 0.1 °C
HM8012
HZ15 (included)
R Offset Function/Relative Value Measurement
R RS-232 Interface and Software included
See page 85 for technical specifications or www.hameg.com/HM8012
Mainframe HM8001-2
required for Operation
25kHz LCR-Meter
HM8018
Option HZ18 Kelvin Test
Lead
R Measurement Functions: L, C, R, Θ, Q/D, |Z|
R Basic Accuracy 0.2 %
R5 Measurement Frequencies:
100 Hz, 120 Hz, 1 kHz, 10 kHz, 25 kHz
HM8018
Option HZ19 SMD Test
Tweezers
R Max. Resolution: 0.001 Ω, 0.001 pF, 0.01 µH
R 2- and 4-Wire Measurement, parallel and series Mode
See page 86 for technical specifications or www.hameg.com/HM8018
Mainframe HM8001-2
required for Operation
39
Modular System Series 8000
1.6 G H z U n i v e r s a l C o u n t e r
HM8021-4
HM8021-4
Mainframe HM8001-2
required for Operation
HZ33, HZ34
Test Cable BNC/BNC
R Measurement Range 0 Hz…1.6 GHz
R 10 MHz Time Base with 1 ppm Stability (TCXO)
RInput A: Input Impedance 1 MΩ, Sensitivity 20 mVrms
Input C: Input Impedance 50 Ω, Sensitivity 30 mVrms
8-Digit Resolution for 10 s Measuring Time
R Time Interval Resolution up to 10 ps
R External Gate Input (with Option HO801)
See page 86 for technical specifications or www.hameg.com/HM8021
10 M H z F u n c t i o n G e n e r a t o r
HM8030-6
HM8030-6
Option HO801, page 38
Mainframe HM8001-2
required for Operation
RFrequency Range 50 mHz…10 MHz,
Output Voltage up to 10 Vpp (into 50 Ω)
R Waveforms: Sine Wave, Triangle, Square Wave, Pulse, DC
RDistortion Factor <0.5 % up to 1 MHz,
Rise and Fall Time typ. 15 ns
R Internal and external Sweep, FM (with Option HO801)
R Surge- and short-circuit-proof Output
40
See page 87 for technical specifications or www.hameg.com/HM8030
Modular System Series 8000
Triple Power Supply
HM8040-3
Silicone Test Lead HZ10R
R 2 x 0…20 V/0.5 A
1 x 5 V/1 A
R 3-Digit switchable Displays (Display Resolution 0.1 V/1 mA)
R Pushbutton for Activating/Deactivating all Outputs
R Adjustable Current Limiting and Electronic Fuse
HM8040-3
Mainframe HM8001-2
required for Operation
R Low Residual Ripple and Low Noise
See page 87 for technical specifications or www.hameg.com/HM8040
Blank Module
HM800
Open Blank Module
R Module for customized Instrument Construction
R Guide Rails for Mounting Circuit Boards at 4 different Levels
HM800
Mainframe HM8001-2
required for Operation
R Plastic Front Panel for easy mechanical Processing
R Power is supplied by the Mainframe HM8001-2
RAvailable Supply Voltages, Load Capability
see Manual of HM800
www.hameg.com/HM800
41
Options
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
42
Options
HO118 Binning Interface
The binning interface option HO118 within the HM8118
enables the LCR bridge to control an external ­binning
hardware in order to physically sort components
according to the measurement result and the user
defined limits. Data lines for eight sorting bins are
provided, as well as output and input control lines
(ALARM, INDEX, EOM, and TRIG). This option is useful
for production testing, component matching or other
tests where similar components must be compared
to each other. The binning feature is an automatic
­process which simplifies the sorting, eliminating the
need to manually compare the parameters. A maxi­
mum of 9 binning configurations can be set using the
store/recall feature. Binning configurations can also
be entered using the communication interface.
Technical Specifications
I/O Connector:
Output signal:
Index:
EOM:
Alarm:
TRIG:
HO3508[HO3516] Logic Probe
D-Sub 25 socket
Negative TRUE, OC (open collector), opto-isolat­
ed, selectable pull-ups. Imax 15 mA @Vce <1 V,
Vce max.: 40 V
pass bins: BIN 0…5 for primary parameter
fail bins: BIN 6
for secondary parameter
BIN 7
for general failure bin
Analog measurement complete
Full measurement complete
Notification that an error was detected
External opto-isolated trigger input,
selectable pull-up, Vmax 15 V, falling edge,
pulse width >10 µs
for all Oscilloscopes of the HMO Series
Multi pin Connector
for Connection of the
Logic Probe
Measurement with the
Logic Probe
RLogic Probe HO3508 for MSO Extension, also available
in a double Package as HO3516 (2 x HO3508)
RWith the Logic Probe HO3508, 8 Logic Channels
(LCH 0…LCH 7 or LCH 8…LCH 15) are available in MSO Mode
RThe Display on the Oscilloscope will be either
as ­individual Channels or as a Bus Display
RDecoding may be in the ASCII, Binary, Decimal or
Hexadecimal Formats
RThe Threshold can be adjusted for 8 Logic Channels
as a Group at the Oscilloscope
RThe Activation of the Logic Channels is indicated
by a LED on the Logic Probe
Specifications HO3508
Channels:
8
Input Impedance:
100 kΩ II <4 pF
Max. Input Frequency:
350 MHz
Max. Input Voltage: 40 V (DC + peak AC)
Measuring Category:
CAT I
Cable Length:
approx. 1 m
43
Options
HO3011 Preamplifier
for Spectrum Analyser of the HMS Series
RPreamplifier Option for HMS1000, HMS1010, HMS3000,
HMS3010 (Licence Key)
RDANL -135 dBm typ. (100 Hz RBW)
HOO10/HOO11 Serial Bus
for all Oscilloscopes of the HMO Series
HOO10
CAN/LIN
See Page 90
RHOO10 via Analog Channels and/or Logic Channels,
HOO11 via Analog Channels
R I2C, SPI, UART/RS-232 Bus Trigger and Decode
R Hardware accelerated Decode in Realtime
RColor Coded Display of the Content for intuitive
­Analysis and easy Overview
RMore Details of the decoded Values become visible
with ­increasing Zoom Factor
RBus Display with synchronous Display of the Data
and maybe Clock Signal
RDecode into ASCII, Binary, Hexadecimal or Decimal
Format
RUp to four Lines to comfortably show the decoded
Values
R Powerful Trigger to isolate specific Messages
ROption for all Oscilloscopes of the HMO Series,
retrofittable
44
I2C Bus Hex Decode on the Analog Channel
See page 89 for technical specifications or www.hameg.com/HOO10 [www.hameg.com/HOO11]
I2C Bus ASCII and Binary Decode of the
Digital Channels
SPI Bus Trigger Setup
Options
HO730 Dual Ethernet/USB Interface
R Ethernet 10/100 MBit/s
R Additionally integrated Web Server
R Screenshot Function using Web Server
R USB 2.0 standard, USB Type B Connector
RFor mounting into Oscilloscopes HM1008, HM1508, HM1008-2,
HM1500-2, HM1508-2, HM2005-2, HM2008, Series HMF, HMO,
HMP and HMS
HO740 IEEE-488 (GPIB) Interface
R 24-pin Connection in accordance with IEEE-488 (GPIB) (Socket)
R Galvanic Separation of Test Device and Interface
RFor mounting into Oscilloscopes HM1008, HM1508, HM1008-2,
HM1500-2, HM1508-2, HM2005-2, HM2008, Series HMF, HMO,
HMP and HMS
HO880 IEEE-488 (GPIB) Interface
R 24-pin Connection in accordance with IEEE-488 (GPIB) (Socket)
R Galvanic Separation of Test Device and Interface
R Up to 15 Devices on one IEEE-488 (GPIB) Bus
RFor installation in Programmable Measuring Instruments
Series 81XX
45
Accessories
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
46
Accessories – Test Cables
H Z 1 0 S i l i co n e Te st L e a d
Silicone test lead with stackable banana plugs.
Length:
Packaging unit:
HZ10R
HZ10B
HZ10S
1.0 m
set of 5
color: red
color: blue
color: black
H Z 1 5 P VC Te st L e a d
PVC test lead with test probes and sheathed banana plugs.
Color:
Length:
Packaging unit:
black and red
1.0 m
1 piece per color
H Z 1 6 Te st C a b le w i t h m i c ro - c l a m p s
Silicone-test lead with BNC plug to miniature clamp probe.
Packaging unit:
1 piece
H Z 1 7 K e lv i n Te st L e a d
Kelvin test lead (4-wire) with test probe,
5-pin DIN connector for HM8018.
Packaging unit:
1 piece
H Z 1 8 K e lv i n Te st L e a d
Kelvin test lead (4-wire) with gold-plated alligator clip,
5-pin DIN connector and shielding mass, for HM8018.
Packaging unit:
1 piece
H Z 1 9 S M D Te st Twe e z e rs
Kelvin test lead (4-wire) with SMD test tweezers,
5-pin DIN connector for HM8018.
Packaging unit:
1 piece
47
Accessories – Test Cables/Adapter
H Z 3 1 Te st C a b le 5 0 Ω
Test cable 50 Ω, BNC to BNC angle connector.
Length:
Packaging unit:
1.0 m
1 piece
H Z 3 2 Te st C a b le
Test cable, BNC to 4 mm banana plug.
Length:
Packaging unit:
1.0 m
1 piece
H Z 3 3 / H Z 3 4 Te st C a b le 5 0 Ω
Test cable 50 Ω, BNC to BNC, BNC straight plug.
Length:
Packaging unit:
0.5 m – HZ33
1 piece
Length:
Packaging unit:
1.0 m – HZ34
1 piece
H Z 3 3 S / H Z 3 4 S Te st C a b le 5 0 Ω
Test cable 50 Ω, BNC to BNC socket, insulated.
Length:
Packaging unit:
0.5 m – HZ33S
1 piece
Length:
Packaging unit:
1.0 m – HZ34S
1 piece
HZ20 Adapter Plug
Adapter BNC plug /4 mm banana socket.
Description:
Packaging unit:
BNC plug with 2 x 4 mm sockets
1 piece
HZ21 Adapter Plug
Adapter N male to BNC female.
Description:
Packaging unit:
48
N male to BNC female
1 piece
Accessories – Adapter/Interfaces/Cables
H Z 2 2 Fe e d - T h ro u g h Te r m i n a t i o n 5 0 Ω
50 Ω feed-through termination, 1 GHz, 2 Watt.
Description:
Packaging unit:
BNC plug BNC socket
1 piece
HZ24 Attenuators 50Ω
One set of 50 Ω attenuators with 3/6/10/20 dB attenuation
(1 GHz, 1 Watt) and 1 HZ22.
Packaging unit:
1 set
HZ26 BNC-T-Adapter
BNC-T-Adapter UG274, 50 Ω.
Description:
Packaging unit:
1 BNC plug to 2 BNC sockets
1 piece
HZ72 IEEE-488 (GPIB) Interface Cable
IEEE-488 (GPIB) bus interface cable double-shielded
90 ° angle, stackable.
Length:
2.0 m
49
Accessories – Probes
HZ154 Probe 1:1/10:1
Attenuation ratio:
Switchable:
Bandwidth:
Rise time :
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
1:1
10:1
10/100 MHz
<35/3.5 ns
1/10 MΩ II 82/12 pF
(10:1) 600 V (DC + peak AC)
1 Trimmer at 10:1
2 Trimmer at 10:1
1.2 m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
500 MHz
<700 ps
10 MΩ II 9.5 pF
400 V (DC + peak AC)
1 Trimmer
2 Trimmer
1.3 m
automatically after connection
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
350 MHz
<1.0 ns
10 MΩ II 12 pF
400 V (DC + peak AC)
1 Trimmer
2 Trimmer
1.2 m
automatically after connection
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
250 MHz
<1.4 ns
10 MΩ II 12 pF
400 V (DC + peak AC)
1 Trimmer
2 Trimmer
1.2 m
automatically after connection
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
10:1
150 MHz
<2.4 ns
10 MΩ II 12 pF
600 V (DC + peak AC)
1 Trimmer
1 Trimmer
1.2 m
CAT I
HZ355 Probe 10:1
HZ350 Probe 10:1
HZ200 Probe 10:1
HZ51 Probe 10:1
50
Accessories – Probes
HZ52 Probe 10:1
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Measuring category:
10:1
250 MHz
<1.4 ns
10 MΩ II 10 pF
600 V (DC + peak AC)
1 Trimmer
2 Trimmer
1.2 m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
Cable length:
Measuring category:
100:1
100 MHz
<3.5 ns
100 MΩ II 4.5 pF
1200 V (DC + peak AC)
1 Trimmer
1.2 m
CAT I
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
1000:1
400 MHz
<900 ps
50 MΩ II 7.5 pF
1000 Vrms
1 Trimmer
1 Trimmer
1.3 m
automatically after connection
CAT II
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Input Voltage:
Input Dynamic Range:
Cable length:
Oscilloscope Input Coupling:
External Power Supply
10:1
1 GHz
600 ps
1 MΩ II 0.9 pF
20 V
±8 V
1.3 m
50 Ω
included
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
LF compensation:
RF compensation:
Cable length:
Probe factor identification:
Measuring category:
10:1
250 MHz
<1.4 ns
10 MΩ II 15 pF
400 V (DC + peak AC)
1 Trimmer
2 Trimmers
1.2 m
automatically after plugging
CAT I
HZ53 Probe 100:1
HZO20 Probe 1000:1
HZO30 Active Probe 10:1
HZO10 Probe 10:1
51
Accessories – Probes
HZ100 Differential Probe 20:1/200:1
Technical specifications at 23 °C ±2 °C
Differential input voltage
(DC + peak AC) max.:
Max. input voltage per input:
Attenuation ratio:
Selectable:
Bandwidth:
Rise time:
Input impedance:
Output impedance:
Max. output Voltage:
Max. noise:
Accuracy after 1 min:
Common mode rejection DC/AC 1 MHz:
Inputs (CAT III):
Input leads:
Battery operation:
Input for an external power supply:
HZ109 Differential Probe 1:1/10:1
Technical specifications at 23 °C ±2 °C
Differential input voltage
(DC + peak AC) max.:
Max. input voltage per input:
Attenuation ratio:
Selectable:
Bandwidth:
Rise time:
Input impedance:
Output impedance:
Max. output Voltage:
Max. background noise at x1:
at x10:
Accuracy after 1min:
Common mode rejection DC/AC 1 MHz:
Inputs (CAT III):
Input leads:
Battery operation:
Input for an external power supply:
HZ115 Differential Probe 100:1/1000:1
Battery operation:
Input for an external power supply:
52
±3,5 V/35 V
100 Vrms
1:1
10:1
30/40 MHz
12/9 ns
8 MΩ II 1.2 pF
50 Ω
±3.5 V at 1 MΩ
<8 mVrms
<2 mVrms
±3 % (18…30 °C)
70 dB/>50 dB
2 safety connectors
2 test leads 50 cm
with spring hooks
9 V battery 6LR61
12…14 Vdc /30 mA
Technical specifications at 23 °C ±2 °C
Differential input voltage (ACrms):
(DC + peak AC) max.:
Max. input voltage per input:
Attenuation ratio:
Selectable:
Bandwidth:
Rise time:
Input impedance:
Output impedance:
Max. output Voltage:
Max. background noise:
Accuracy after 1 min:
Common mode rejection DC/AC 1 MHz:
Inputs (CAT III):
Input leads:
*) due to test clip 1000 V CAT III
±700 V
600 Vrms
20:1
200:1
30/40 MHz
12/9 ns
8 MΩ II 1.2 pF
50 Ω
±3.5 V at 1 MΩ
2 mV
±3 % (18…30 °C)
70 dB/>50 dB
2 safety connectors
2 test leads 50 cm
with spring hooks
9 V battery 6LR61
12…14 Vdc /30 mA
1000 V
±1400 V*)
±1400 V*)
100:1
1000:1
20/30 MHz
17/12 ns
60 MΩ II 1.5 pF
50 Ω
±1.5 V at 1 MΩ
2 mV
±3 % (18…30 °C)
70 dB/>50 dB
2 safety connectors
2 test leads 75 cm
with safety test clips
9 V battery 6LR61
12…14 Vdc /30 mA
Accessories – Probes
HZO40 Differential Probe 10:1
Technical specifications at 23 °C ±2 °C
Bandwidth:
Attenuation ratio:
Rise time (10…90 %):
Gain accuracy:
Max. Input Voltage per Input:
Max. Differential Input
Voltage (DC + peak AC):
Max. Common Mode
Input Voltage:
Input impedance
Between Inputs:
Each Input to Ground:
Output Voltage (into 50 Ω):
Offset (typical):
CMRR (typical):
Battery operation:
Battery life (typical):
Input for an external
power supply:
HZO41 Differential Probe 10:1
±20 V
±60 V
1 MΩ II 3.5 pF
500 kΩ II 7 pF
±2 V
±2 mV
-80 dB at 60 Hz
-50 dB at 10 MHz
9 V battery 6LR61
7.5 h
USB Power adapter cable
(5…9 V DC /200 mA)
Technical specifications at 23 °C ±2 °C
Bandwidth:
Attenuation ratio:
Rise time (10…90 %):
Gain accuracy:
Max. Input Voltage per Input:
Max. Differential Input
Voltage (DC + peak AC):
Max. Common Mode
Input Voltage:
Input impedance
Between Inputs:
Each Input to Ground:
Output Voltage (into 50 Ω):
Offset (typical):
CMRR (typical):
Battery operation:
Battery life (typical):
Input for an external
power supply:
200 MHz
10:1
1.75 ns
±1 %
±60 V
800 MHz
10:1
437 ps
±2 %
±40 V
±15 V
±30 V
200 kΩ II 1 pF
100 kΩ II 2 pF
±1.5 V
±5 mV
-60 dB at 60 Hz
-15 dB at 500 MHz
9 V battery 6LR61
4.5 h
USB Power adapter
cable (5…9 VDC /300 mA)
53
Accessories – Probes
HZO50 AC/DC Current Probe 30A
This AC/DC current probe is used to measure currents from 1 mA
to 30 A over a broad frequency range. The measure­ment principle is
based on the Hall Effect that registers the magnetic field generated
by the current flow. Even for complex waveforms a high degree of
measurement accu­racy is achieved. The output voltage is propor­
tional to the measured current and well suited to be displayed on
an oscilloscope. The current probe complies with the safety stand­
ards defined in IEC/EN 61010.
Current measurement
with HMO
Specifications
Measurement range:
Accuracy:
Bandwidth:
Resolution:
Output Voltage:
Load impedance:
Max. Voltage:
Output cable/Connector:
Measuring category:
±20 Arms /30 Ap
±1 % from measurement value ±2 mA
DC…100 kHz (0.5 dB)
±1 mA
100 mV/A
>100 kΩ II ≤100 pF
300 Vrms (AC or DC)
2 m (50 Ω)/BNC
CAT III
HZO51 AC/DC Current Probe 100A/1000A
This AC/DC current probe is used to measure currents from 100 mA
to 1000 A over a broad frequency range. The measure­ment prin­
ciple is based on the Hall Effect that registers the magnetic field
generated by the current flow. Even for complex waveforms a high
degree of measurement accu­racy is achieved. The output voltage
is proportional to the measured current and well suited to be dis­
played on an oscilloscope. The current probe complies with the
safety standards defined in IEC/EN 61010.
Current measurement
with HMO
Specifications
Measurement range:
Accuracy:
Bandwidth:
Resolution:
Output Voltage:
Load impedance:
Max. Voltage:
Output cable/Connector:
Measuring category:
±100 Arms /1000 Arms
±1 % from measurement value ±0.1 A /±0.5 A
DC…20 kHz
±100 mA/±500 mA
10 mV/A/1 mV/A
>100 kΩ II ≤100 pF
300 Vrms (AC or DC)
2 m (50 Ω)/BNC
CAT III
Frequency range:
Impedance:
VSWR:
DC…6 GHz
50 Ω
1.05 (DC…1 GHz)
1.1 (1…4 GHz)
1.2 (4…6 GHz)
1 W aver.
N-male
H Z 5 2 5 Te r m i n a t i o n
Power:
Connection:
54
Accessories – Converter/Sensors/Test fixtures
HZ575 Converter
HZ575 is a 75 Ω to 50 Ω converter enabling measurement in 75 Ω sys­
tems in connection with 50 Ω input impedance spectrum analyzers.
The 75 Ω input is a 75 Ω BNC socket which is AC coupled internally.
The output is a 50 Ω N male connector which is DC coupled. HZ575
can also be used for reverse operation converting 50 Ω to 75 Ω.
Specifications
Frequency Range:
Insertion loss:
Max. Level/Voltage
at 75 Ω connector:
at 50 Ω connector:
Dimensions:
Weight:
5 MHz…1.2 GHz
less than 1 dB
+10 dBm/±20 Vdc
+10 dBm/0 Vdc
25 x 25 x 58 mm (W x H x D)
100 g
H Z 8 1 2 / H Z 8 8 7 P T 1 0 0 Te m p e ra t u re P ro b e
The HZ812 and HZ887 Temperature Probes are immersion sensors
with PT100 sensing resistors. They ensure excellent precision over
a broad temperature range. The probes are of robust construction,
waterproof and also suitable for use in air or dusty environments.
The technical specifications apply for immersion depths of at least
60 mm.
HZ812
The probe is connected to the measuring instrument either with a
2-pin connection using a safety plug (HZ812) or with a 4-pin con­
nection via a 4 mm banana plug (HZ887). The length of the connec­
tor cable is 1.2 m for both probes.
HZ812 is suitable for use in combination with HM8012
HZ887 is suitable for use in combination with HM8112
Technical specifications in accordance with EN60751
(formerly IEC751)
HZ887
Probe diameter:
Measurement range:
Accuracy, Class A:
t99 (s):
Connection HZ812:
Temperature measure­
ment HZ887 in combi­nation
with HM8112-3
Connection HZ887:
4 mm
-50…+400 °C
±(0.2 % of the reading + 0.15 °C)
12 s (time required to display
99 % of the temperature change)
Safety plug, 4 mm,
1.2 m PVC cable
4 mm banana plug,
1.2 m PVC cable
Accuracy, HZ812 in combination with HM8012:
-50 °C <T° <200 °C
±(0.2 % of reading +0.25 °C)
200 °C <T° <400 °C
±(0.2 % of reading +0.45 °C)
55
Accessories – LCR-Bridge HM8118/Test Adapter
HZ181
4 Te r m i n a l Te st F i x t u re i n c l u d i n g S h o r t i n g P l a te
4 Terminal Test Fixture including Shorting Plate (for HM8118) for
evaluation of lead type devices.
HZ184
4 Te r m i n a l K e lv i n Te st C a b le
The 4 Terminal Kelvin Test Cable with Kelvin clips (for HM8118,
included in delivery) makes it possible to measure odd-shaped
components that cannot be measured with conventional fixtures.
HZ186
4 Te r m i n a l Tra n s fo r m e r Te st C a b le
Transformer Test Cable (for HM8118) for transformer measurements.
HZ188
4 Te r m i n a l S M D C o m p o n e n t Te st F i x t u re
4 Terminal SMD Component Test Fixture (for HM8118, included in
delivery) for evaluation of SMD components.
HZ809
Te st A d a p te r fo r M o d u l a r S y ste m S e r i e s 8 0 0 0
Test adapter for the testing and repair of insert modules for
Mo­dular System Series 8000 outside the mainframe HM8001-2.
The module connection terminals in the basic unit are led through
1 to 1. The modules can then be operated outside the mainframe
while the housing is open.
HZ815
Power Adapter for HM8115-2
Adapter for simplified measurement of power consump­tion, line
voltage and current consumption of mains operated gear (3-wire
safety plug or European standard plug) using the HM8115-2 Power
Meter.
56
Accessories – Spectrum Analyzer
HZ520 Plug-in Antenna
Telescopic Antenna for RF reception
BNC connector
HZ547 VSWR Bridge
This unit is used to measure the voltage standing wave ratio
(VSWR) and the reflection coefficient of a device under test with an
impedance of 50 Ω.
Typical test objects include attenuators, terminations, frequency
switches, amplifiers, cables and mixers.
Frequency range:
Impedance:
Directivity:
HZ547 connected with
HMS3010
Reflection loss
at DUT port:
Insertion loss
IN t OUT:
IN t OUT:
IN t DUT:
DUT t OUT:
Max. Power Dissipation:
Connectors:
Dimensions:
Weight:
Temperature range:
Accessories supplied:
100 kHz…3 GHz
50 Ω
>28 dB (100…300 kHz)
>35 dB (300 kHz…1 GHz)
>30 dB (1…3 GHz)
>20 dB
20 dB (100…300 kHz)
18 dB (300 kHz…3 GHz)
1.7 dB
16 dB
+26 dBm
N (female)
150 x 68 x 29.5 mm
(W x H x D), without connectors
approx. 650 g
+10…+45 °C
HZ525 (Termination 50 Ω 1 W),
N male to N male (2 pcs.),
Carrying case
265 x 225 x 50 mm (W x H x D)
Technical specifications: (typical values) see www.hameg.com/HZ547
HZ560 Transient Limiter
The HZ560 Transient Limiter protects the input circuits of spec­
trum analyzers and test receivers.
The input of the Transient Limiter is connected via BNC cable to the
signal source. The output can be connected directly to the spec­
trum analyzer.
Frequency range:
Insertion loss:
Max. input level:
Max. input voltage:
VSWR:
Connections:
Dimensions:
150 kHz…30 MHz
a = 10 dB + 1.5/-0.5 dB
at f <1 kHz a ≥90 dB
at f <10 kHz a ≥50 dB
10 dB (+1.5/-0.5 dB)
+33 dBm (2 W, average)
±50 Vdc
1.5:1 or better
BNC (input and output)
67 x 32 x 32 mm (W x H x D)
Technical specifications at 23 °C ±2 °C
57
Accessories – Rackmount Kits
HZ42
2RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 75 mm
(for Series 8100, HM8143, HM7042-5, HM8001-2, HMP2020,
HMP2030 and HMF Series).
Dimensions (W x D): 440 x 360 mm
plus overhang of the instrument
2 RU:
88 mm
Please order instruments, which are installed into HZ42, with note „without housing feet“,
as otherwise the feet must be dismounted before installation.
HZ43
3RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 125 mm
(for HM2005, HM303-6, HM504-2, HM507, HM5510, HM5014-2,
HM5530, HM6050-2, HM7044, HMP4030*, HMP4040*).
Dimensions (W x D): 440 x 360 mm
plus overhang of the instrument
3 RU:
132.5 mm
When ordering instruments which are to be used with the HZ43 option installed, please
state expressly "without feet", because, if space is at a premium, those might have to be
dismantled before the instrument can be placed.
* For reasons of stability and weight, if the space available in the rack permits, we recom­
mend the HZP91. It allows to install and remove the instrument even with the feet in place.
HZ45
4RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 125 mm
(for HM400, HM1000, HM1000-2, HM1008, HM1008-2, HM1500,
HM1500-2, HM1508, HM1508-2, HM2005-2, HM2008).
Dimensions (W x D): 440 x 360 mm
plus overhang of the instrument
4 RU:
177 mm
HZ46
4RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 175 mm
(for HMO3522/24, HMO2524 and HMS Series).
Dimensions (W x D): 440 x 170 mm
plus overhang of the instrument
4 RU:
177 mm
58
Accessories – Rackmount Kits/Carrying Cases
HZO91
4RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 175 mm
(for HMO72x, HMO102x, HMO152x, HMO202x).
Dimensions (W x D): 440 x 110 mm
plus overhang of the instrument
4 RU:
177 mm
HZP91
4RU 19“ Rackmount Kit
For mounting HAMEG instruments with a case height of 125 mm
(for HMP4030, HMP4040).
Dimensions (W x D): 440 x 360 mm
plus overhang of the instrument
4 RU:
177 mm
HZ99
Carrying Case
We recommend the HZ99 Carrying Case for protection and trans­
port of oscilloscopes (HMO series) and spectrum analyzers (HMS
series). The instruments can be transported conveniently and safely
in the case. An extra pocket provides space for test gear and acces­
sories.
Running the device inside the case is not permitted.
(HMO2524, HMO352x, HMS)
HZO90
Carrying Case
We recommend the HZO90 Carrying Case for protection and trans­
port of oscilloscopes (HMO series). The instruments can be trans­
ported conveniently and safely in the case. An extra pocket provides
space for test gear and accessories.
Running the device inside the case is not permitted.
(HMO72x, HMO102x, HMO152x, HMO202x)
59
Specifications
Oscilloscopes
Spectrum Analysis
Power Supplies
Programmable Measuring Instruments
Series 8100
Modular System Series 8000
Options
Accessories
Specifications
60
Specifications
Vertical
Number of Channel
Bandwidth
Input Impedance
V/div. 1 MΩ
HMO3522
[HMO3524]
HMO2524
HMO2022
[HMO2024]
HMO1022
[HMO1024]
HMO722
[HMO724]
2 [4]
4
2 [4]
2 [4]
2 [4]
2 [4]
350 MHz
250 MHz
200 MHz
150 MHz
100 MHz
70 MHz
1 MΩ/50 Ω
1 MΩ/50 Ω
1 MΩ/50 Ω
1 MΩ/50 Ω
1 MΩ
1 MΩ
1 mV/div.…5 V/div.
1 mV/div.…5 V/div.
1 mV/div.…5 V/div.
1 mV/div.…5 V/div.
1 mV/div.…10 V/div.
1 mV/div.…10 V/div.
1 mV/div.…1 V/div.
1 mV/div.…1 V/div.
1 mV/div.…1 V/div.
N/A
N/A
Max. Input voltage 1 MΩ
V/div. 50 Ω
HMO1522
[HMO1524]
200 Vpk
Probe Attenuation Sense
1 mV/div.…1 V/div.
Standard
Horizontal
Sample Rate
per Analog Channel
Max. Sample Rate
2 GSa/s
1.25 GSa/s
1 GSa/s
1 GSa/s
1 GSa/s
1 GSa/s
4 GSa/s
2.5 GSa/s
2 GSa/s
2 GSa/s
2 GSa/s
2 GSa/s
Memory Depth per Ch.
2 MPts.
2 MPts.
1 MPts.
1 MPts.
1 MPts.
1 MPts.
Max. Memory
4 MPts.
4 MPts.
2 MPts.
2 MPts.
2 MPts.
2 MPts.
Timebase Accuracy
15 ppm
15 ppm
50 ppm
50 ppm
50 ppm
50 ppm
2500 wfs/s
2500 wfs/s
2000 wfs/s
2000 wfs/s
2000 wfs/s
2000 wfs/s
Trigger
Trigger Rate
Trigger Modes
Edge, Pulse Width, Pattern, Video inl. HDTV, A/B Trigger
Measurement
Cursormeasurement
List
ΔV, Δt, 1/Δt (f), V to Gnd, Vt related to Trigger point, ratio X and Y, pulse count, peak to peak, peak+, peakFrequency, Period, pulse count, Vpp, Vp+, Vp-, Vrms, Vavg, Vtop, Vbase, twidth+, twidth-, tdutycycle+, tdutycycle, trise, tfall,
pos. edge count, neg. edge count, pos. pulse count, neg. pulse count"
6 Digit
Parameter List
HW Counter
Advanced Math,
Math on Math
Math Functions std.
Standard
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG, INV, INTG, DIFF, SQR, MIN, MAX, LOG, LN, Filter (low-pass, high-pass)
Pass/Fail Mask testing
Standard
Mixed Signal
via Option HO3508 (8 Channel)
Mixed Signal
or HO3516 (16 Channel)
­Functionality
Max. Number
16
16
of Logic Channel
Sample Rate of the
1,25 GSa/s
1 GSa/s
Digital Channel
Memory Depth of the
1 MPts.
2 MPts.
Digital Channel
Serial Trigger and Decode
Serial Trigger and Decode
I2C, SPI, UART/RS-232
Display
via Option HO3508 (8 Channel)
8
8
8
8
1 GSa/s
1 GSa/s
1 GSa/s
1 GSa/s
1 MPts.
1 MPts.
1 MPts.
1 MPts.
HOO10 via Analog Channels and/or Logic Channels, HOO11 via Analog Channels
Display Size
6.5 inch
Display Resolution
640 x 480
Virtual Screen
20 div.
Interfaces
Monitor Output
Standard: DVI-D
USB Remote Interface
Standard
RS-232 Remote
Interface
Ethernet Remote
Interface
GPIB Remote Interface
Standard
Option HO730
Option HO740
Miscellaneous
Fan noise
Dimension (W x H x D)
Footprint
very low
28.5 x 17.5 x 22 cm
28.5 x 17.5 x 22 cm
28.5 x 17.5 x 14 cm
28.5 x 17.5 x 14 cm
28.5 x 17.5 x 14 cm
28.5 x 17.5 x 14 cm
627 cm2
627 cm2
399 cm2
399 cm2
399 cm2
399 cm2
Weight
3.6 kg
3.6 kg
2.5 kg
2.5 kg
2.5 kg
2.5 kg
Power
70 W max.
70 W max.
55 W max.
55 W max.
55 W max.
55 W max.
N/A
N/A
Standard
Standard
Standard
Standard
Component Tester
Additional
Bus Signal Source
Languages
Standard
German, English, French, Spain
61
Specifications
Probe ADJ Output:
40 MHz Analog Oscilloscope HM400
Product description, page 11
Vertical Deflection
Operating Modes:
Invert:
XY Mode:
Bandwidth (-3 dB):
DC, 5 mV/div.…20 V/div.:
AC, 5 mV/div.…20 V/div.:
DC, 1…2 mV/div.:
AC, 1…2 mV/div.:
Rise Time (calculated):
Deflection Coefficient:
Variable (uncalibrated):
Input Impedance:
Input Coupling:
Max. Input Voltage:
Triggering
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Slope:
Sources:
Coupling:
Channel 1 or 2 only
Channels 1 and 2 (alternate or chopped)
Sum or Difference of CH 1 and CH 2
CH 2
CH 1 (X) and CH 2 (Y)
0…40 MHz
2 Hz…40 MHz
0…10 MHz
2 Hz…10 MHz
<35 ns (1…2 mV/div.)
<8.75 ns (5 mV/div.…20 V/div.)
1–2–5 Sequence
±5 % (1…2 mV/div.)
±3 % (5 mV/div.…20 V/div.)
>2.5:1 to >50 V/div.
1 MΩ II 15 pF
DC, AC, GND (ground)
400 V (DC + peak AC)
Linking of peak detection and trigger level
0.5 div.
5 Hz…50 MHz
From peak- to peak+
0.5 div.
0…50 MHz
-10….+10 div.
Rising or falling
Channel 1 or 2, Line and External
AC (5 Hz…80 MHz),
DC (0…80 MHz),
LF (0…1.5 kHz)
LED
Trigger Indicator:
External Trigger:
1 MΩ II 15 pF
Input Impedance:
External Trigger Signal: 0.3 Vpp ≤5 V,
DC (0…50 MHz),
AC (20 Hz…50 MHz)
100 V (DC + peak AC)
Max. input voltage:
Field and Line, +/Active TV sync. separator:
Horizontal Deflection
Time Base:
Accuracy:
Variable (uncalibrated):
X Magnification x10:
Accuracy:
Hold-Off Time:
XY
Bandwidth X amplifier:
XY Phase shift <3°:
100 ns/div..…0.2 s/div (1–2–5 Sequence)
±3 %
>2.5:1 to >1.25 s/div.
up to 10 ns/div.
±5 %
variable to approx. 10:1
0…2.5 MHz (-3 dB)
<120 kHz
Operation/Readout/Control
via controls and buttons
Manual:
automatic signal related parameter settings
Autoset:
6 instrument parameter settings
Save and Recall:
Component Tester
Test Voltage:
Test Current:
Test Frequency:
Test Connection:
Miscellaneous
CRT:
Acceleration Voltage:
Trace Rotation:
Z-Input (Intens. modulation):
62
approx. 7 Vrms (open circuit)
max. 7 mArms (short-circuit)
approx. 50 Hz
2 banana jacks 4 mm Ø
One test circuit lead is grounded
via protective earth (PE)
D14-363GY, 8 x 10 div. with internal graticule
approx. 2 kV
adjustable on front panel
max. +5 V (TTL), 10 kHz
Power Supply (Mains):
Power Consumption:
Safety class:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
1 kHz/1 MHz Square Wave Signal approx.
0.2 Vpp (tr <5 ns) for probe adjustment
105…253 V, 50…60 Hz ±10 %, CAT II
approx. 30 W at 230 V/50 Hz
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 125 x 380 mm
approx. 4.8 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line Cord, Operating Manual, 2 Probes 1:1/10:1 (HZ154)
with LF/HF adjustment, CD
Recommended accessories:
HZ20 Adapter, BNC to 4 mm banana
HZ33 Test cable 50 Ω, BNC/BNC, 0.5 m
HZ34 Test cable 50 Ω, BNC/BNC, 1 m
HZ45 19‘‘-Rackmount Kit 4RU
HZ51 Probe 10:1 (150 MHz)
HZ52 Probe 10:1 RF (250 MHz)
HZ53 Probe 100:1 (100 MHz)
HZ100 Differential probe 20:1/200:1
HZ109 Differential probe 1:1/10:1
HZ115 Differential probe 100:1/1000:1
HZ200 Probe 10:1 with auto attenuation ID (250 MHz)
HZ350 Probe 10:1 with automatic identification (350 MHz)
HZ355 Slimline probe 10:1 with automatic identification (500 MHz)
HZO20 High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO30 Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO50 AC/DC Current probe 20 A, DC…100 kHz
HZO51 AC/DC Current probe 1000 A, DC…20 kHz
70 MHz 2 [4] Channel Digital Oscilloscope
HMO722 [HMO724]
Product description, page 9
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per channel:
Vertical System
Channels:
DSO mode
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1, CH 2 [CH 1…CH 4]
CH 1, CH 2, LCH 0…7 (logic channels)
[CH 1, CH 2, LCH 0…7, CH 4]
with Option HO3508
Frontside [Rear side]
Ext. Trigger
1 MΩ || 13 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1, CH 2 [CH 1…CH 4]
70 MHz (5 mV…10 V)/div.
20 MHz (1 mV, 2 mV)/div.
2 Hz
Lower AC bandwidth:
Bandwidth limiter
approx. 20 MHz
(switchable):
<5 ns
Rise time (calculated):
2 %
DC gain accuracy
13 calibrated steps
Input sensitivity:
CH 1, CH 2 [CH 1…CH 4] 1 mV/div.…10 V/div. (1–2–5 Sequence)
Between calibrated steps
Variable
Inputs CH 1, CH 2 [CH 1…CH 4]:
1 MΩ II 14 pF ±2 pF
Impedance
DC, AC, GND
Coupling
Specifications
Max. input voltage
Measuring circuits:
Position range
Logic channels
Select. switching
­thresholds
Impedance
Coupling
Max. input voltage
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources:
Coupling
(Analog Channel):
Video:
Standards
Fields
Line
Sync. Impulse
Sources:
Logic:
Sources:
State
Pulses:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope:
Min. signal height
Frequency range
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
I2C
SPI
UART/RS-232
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Roll Mode:
Digital Storage
Sampling rate (real time):
200 V (DC + peak AC)
Measuring Category I (CAT I)
±10 Divs
With Option HO3508
TTL, CMOS, ECL, User -2…+8 V
100 kΩ || <4 pF
DC
40 V (DC + peak AC)
Linking of peak detection and trigger level
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
5 Hz…100 MHz (5 Hz…30 MHz at ≤2 mV/div.)
From peak- to peak+
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…100 MHz (0 Hz…30 MHz at ≤2 mV/div.)
-10…+10 div.
Slope/Video/Logic/Pulses/Buses (optional)
Rising, falling, both
CH 1, CH 2, Line, Ext., LCH 0…7
[CH 1…CH 4, Line, Ext., LCH 0…7]
AC: 5 Hz…100 MHz
DC: 0…100 MHz
HF: 30 kHz…100 MHz
LF: 0…5 kHz
Noise rejection: selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
All, selectable line number
Positive, negative
CH 1, CH 2, Ext. [CH 1…CH 4]
AND, OR, TRUE, FALSE
LCH 0…7
LCH 0…7 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 32 ns, max. 10 s, resolution min. 8 ns
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…100 MHz (0 Hz…30 MHz at ≤2 mV/div.)
-10…+10 div.
32 ns…10 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
Time, Frequency (FFT), Voltage (XY)
Main-window, main- and zoom-window
Up to 50,000:1
50 ppm
2 ns/div.…50 s/div.
50 ms/div.…50 s/div.
2 x 1 GSa/s, 1 x 2 GSa/s [4 x 1 GSa/s, 2 x 2 GSa/s]
Logic channels: 8 x 1 GSa/s
Memory:
Operation modes:
Resolution (vertical)
Resolution (horizontal)
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
2 x 1 MPts, 1 x 2 MPts
[4 x 1 MPts, 2 x 2 MPts]
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter, HiRes
8 Bit, (HiRes up to 10 Bit)
40 ps
Sinx/x, linear, Sample-hold
Off, 50 ms…∞
0…8 Million x (1/samplerate)
0…2 Million x (1/samplerate)
Up to 2000 waveforms/s
Dots, vectors, ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…100 MHz
50 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, Vtop, Vbase,
frequency, period, pulse count,
twidth+, twidth-, tdutycycle+, tdutycycle, trise, tfall,
pos. edge count, neg. edge count,
pos. pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB type B/RS-232 (HO720),
Interface:
2 x USB type A (front- and rear side
each 1 x) max. 100 mA,
DVI-D for ext. Monitor
IEEE-488 (GPIB) (HO740),
Optional:
Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
Parallel
I2C
(Opt. HOO10, HOO11)
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for
all Math-, Logic-, Bus- and Reference
Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
­v alue in ASCII, binary, decimal or hexa­
decimal, up to 4 lines
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing
acknowledge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/ X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX, LOG,
LN, Low-, High-pass filter
Up to 4 math. memories with label
Analog channels
Mask around a signal, userdefined
tolerance
Stop, Beep, screen shot (screen print-out)
and/or output to printer for pass or fail,
event counting up to 4 billion, including
the number and the percentage of pass
and fail events
63
Specifications
General Information
Component tester
Test voltage:
Test current:
Test frequency:
Reference Potential:
Probe ADJ Output:
Bus Signal Source
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
10 VP (open) typ.
10 mAP (short) typ.
50 Hz / 200 Hz typ.
Ground (safety earth)
1 kHz/1 MHz square wave signal ~1 Vpp
(ta <4 ns)
SPI, I2C, UART, Parallel (4 Bit)
Date and time for stored data
100…240 V, 50…60 Hz, CAT II
Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W]
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 140 mm
<2.5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, 2 [4] Probes,
10:1/1:1 switchable (HZ154), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Logic channels and Analog channels
H0011Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB) galvanically isolated
HZO91 4RU 19‘‘ Rackmount Kit
HZO90 Carrying Case for protection and transport
HZO20 High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO30 Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO50 AC/DC Current probe 20 A, DC…100 kHz
HZO51 AC/DC Current probe 1000 A, DC…20 kHz
100 MHz 2 [4] Channel Digital Oscilloscope
HMO1022 [HMO1024]
Product description, page 9
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per channel:
Vertical System
Channels:
DSO mode
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
Lower AC bandwidth:
Bandwidth limiter
(switchable):
Rise time (calculated):
DC gain accuracy
Input sensitivity:
64
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1, CH 2 [CH 1…CH 4]
CH 1, CH 2, LCH 0…7 (logic channels)
[CH 1, CH 2, LCH 0…7, CH 4]
with Option HO3508
Frontside [Rear side]
Ext. Trigger
1 MΩ || 13 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1, CH 2 [CH 1…CH 4]
100 MHz (5 mV…10 V)/div.
20 MHz (1 mV, 2 mV)/div.
2 Hz
approx. 20 MHz
<3.5 ns
2 %
13 calibrated steps
CH 1, CH 2 [CH 1…CH 4] 1 mV/div.…10 V/div. (1–2–5 Sequence)
Between calibrated steps
Variable
Inputs CH 1, CH 2 [CH 1…CH 4]:
1 MΩ II 14 pF ±2 pF
Impedance
DC, AC, GND
Coupling
200 V (DC + peak AC)
Max. input voltage
Measuring Category I (CAT I)
Measuring circuits:
±10 Divs
Position range
With Option HO3508
Logic channels
Select. switching
TTL, CMOS, ECL, User -2…+8 V
­thresholds
100 kΩ || <4 pF
Impedance
DC
Coupling
40 V (DC + peak AC)
Max. input voltage
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources:
Coupling
(Analog Channel):
Video:
Standards
Fields
Line
Sync. Impulse
Sources:
Logic:
Sources:
State
Pulses:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope:
Min. signal height
Frequency range
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
I2C
SPI
UART/RS-232
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Linking of peak detection and trigger level
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
5 Hz…150 MHz (5 Hz…30 MHz at ≤2 mV/div.)
From peak- to peak+
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…150 MHz (0 Hz…30 MHz at ≤2 mV/div.)
-10…+10 div.
Slope/Video/Logic/Pulses/Buses (optional)
Rising, falling, both
CH 1, CH 2, Line, Ext., LCH 0…7
[CH 1…CH 4, Line, Ext., LCH 0…7]
AC: 5 Hz…150 MHz
DC: 0…150 MHz
HF: 30 kHz…150 MHz
LF: 0…5 kHz
Noise rejection: selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
All, selectable line number
Positive, negative
CH 1, CH 2, Ext. [CH 1…CH 4]
AND, OR, TRUE, FALSE
LCH 0…7
LCH 0…7 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 32 ns, max. 10 s, resolution min. 8 ns
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…150 MHz (0 Hz…30 MHz at ≤2 mV/div.)
-10…+10 div.
32 ns…10 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
Time, Frequency (FFT), Voltage (XY)
Main-window, main- and zoom-window
Up to 50,000:1
50 ppm
2 ns/div.…50 s/div.
Specifications
Roll Mode:
Digital Storage
Sampling rate (real time):
Memory:
Operation modes:
Resolution (vertical):
Resolution (horizontal):
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
50 ms/div.…50 s/div.
2 x 1 GSa/s, 1 x 2 GSa/s
[4 x 1 GSa/s, 2 x 2 GSa/s]
Logic channels: 8 x 1 GSa/s
2 x 1 MPts, 1 x 2 MPts
[4 x 1 MPts, 2 x 2 MPts]
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter, HiRes
8 Bit, (HiRes up to 10 Bit)
40 ps
Sinx/x, linear, Sample-hold
Off, 50 ms…∞
0…8 Million x (1/samplerate)
0…2 Million x (1/samplerate)
Up to 2000 waveforms/s
Dots, vectors, ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…150 MHz
50 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, V top, V base,
frequency, period, pulse count,
t width+, t width-, tdutycycle+, tdutycycle, trise, t fall,
pos. edge count, neg. edge count, pos.
pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB type B/RS-232 (HO720),
Interface:
2 x USB type A (front- and rear side
each 1 x) max. 100 mA,
DVI-D for ext. Monitor
IEEE-488 (GPIB) (HO740),
Optional:
Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
Parallel
I2C
(Opt. HOO10, HOO11)
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for
all Math-, Logic-, Bus- and Reference
Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
value in ASCII, binary, decimal or
hexadecimal, up to 4 lines
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing
acknowledge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/ X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX,
LOG, LN, Low-, High-pass filter
Up to 4 math. memories with label
Analog channels
Mask around a signal, userdefined
tolerance
Functions:
Stop, Beep, screen shot (screen print-out)
and/or output to printer for pass or fail,
event counting up to 4 billion, including
the number and the percentage of pass
and fail events
General Information
Component tester
Test voltage:
Test current:
Test frequency:
Reference Potential:
Probe ADJ Output:
Bus Signal Source
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
10 VP (open) typ.
10 mAP (short) typ.
50 Hz / 200 Hz typ.
Ground (safety earth)
1 kHz/1 MHz square wave signal ~1 Vpp
(ta <4 ns)
SPI, I2C, UART, Parallel (4 Bit)
Date and time for stored data
100…240 V, 50…60 Hz, CAT II
Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W]
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 140 mm
<2.5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, 2 [4] Probes,
10:1/1:1 switchable (HZ154), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Logic channels and Analog channels
HOO11Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB) galvanically isolated
HZO91 4RU 19‘‘ Rackmount Kit
HZO90 Carrying Case for protection and transport
HZO20 High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO30 Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO50 AC/DC Current probe 20 A, DC…100 kHz
HZO51 AC/DC Current probe 1000 A, DC…20 kHz
150 MHz 2 [4] Channel Digital Oscilloscope
HMO1522 [HMO1524]
Product description, page 8
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per trace:
Vertical System
Channels:
DSO mode
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1, CH 2 [CH 1…CH 4]
CH 1, CH 2, LCH 0…7 (logic channels)
[CH 1, CH 2, LCH 0…7, CH4]
with Option HO3508
Frontside [Rear side]
Ext. Trigger
1 MΩ || 14 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1, CH 2 [CH 1…CH 4]
150 MHz (5 mV…10 V)/div.
100 MHz (1 mV, 2 mV)/div.
65
Specifications
2 Hz
Lower AC bandwidth:
Bandwidth limiter
approx. 20 MHz
(switchable):
<2.4 ns
Rise time (calculated):
2 %
DC gain accuracy
12 calibrated steps
Input sensitivity:
CH 1, CH 2 [CH 1…CH 4] 1 mV/div.…10 V/div. (1–2–5 Sequence)
Between calibrated steps
Variable
Inputs CH 1, CH 2 [CH 1…CH 4]:
1 MΩ || 14 pF ±2 pF (50 Ω switchable)
Impedance
DC, AC, GND
Coupling
200 V (DC + peak AC), 50 Ω <5 Vrms
Max. input voltage
Measuring Category I (CAT I)
Measuring circuits:
±10 Divs
Position range
Offset control:
±0,2 V - 10 div. x Sensitivity
1 mV, 2 mV
±1 V - 10 div. x Sensitivity
5…50 mV
±2,5 V - 10 div. x Sensitivity
100 mV
±40 V - 10 div. x Sensitivity
200 mV…2 V
±100 V - 10 div. x Sensitivity
5 V
With Option HO3508
Logic channels
Select. switching
TTL, CMOS, ECL, User -2…+8 V
t­hresholds
100 kΩ || <4 pF
Impedance
DC
Coupling
40 V (DC + peak AC)
Max. input voltage
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources:
Coupling
(Analog Channel):
Video:
Standards
Fields
Line
Sync. Impulse
Sources:
Logic:
Sources:
State
Pulses:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope:
Min. signal height
Frequency range
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
66
Linking of peak detection and trigger level
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/ div.)
5 Hz…200 MHz (5 Hz…120 MHz at ≤2 mV/div.)
From peak- to peak+
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…200 MHz (0 Hz…120 MHz at ≤2 mV/div.)
-10…+10 div from center of the screen
Slope/Video/Logic/Pulses/Buses (optional)
Rising, falling, both
CH 1, CH 2, Line, Ext., LCH 0…7
[CH 1…CH 4, Line, Ext., LCH 0…7]
AC: 5 Hz…200 MHz
DC: 0…200 MHz
HF: 30 kHz…200 MHz
LF: 0…5 kHz
Noise rejection: selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
All, selectable line number
Positive, negative
CH 1, CH 2, Ext. [CH 1…CH 4]
AND, OR, TRUE, FALSE
LCH 0…7
LCH 0…7 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 32 ns, max. 10 s, resolution min. 8 ns
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…200 MHz (0 Hz…120 MHz at ≤2 mV/div.)
-10…+10 div.
32 ns…10 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
I2C
SPI
UART/RS-232
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Roll Mode:
Digital Storage
Sampling rate (real time):
Memory:
Operation modes:
Resolution (vertical):
Resolution (horizontal):
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
Time, Frequency (FFT), Voltage (XY)
Main-window, main- and zoom-window
Up to 50,000:1
50 ppm
2 ns/div.…50 s/div.
50 ms/div.…50 s/div.
2 x 1G Sa/s, 1 x 2 GSa/s
[4 x 1 GSa/s, 2 x 2 GSa/s]
Logic channels: 8 x 1 GSa/s
2 x 1 MPts, 1 x 2 MPts
[4 x 1 MPts, 2 x 2 MPts]
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter, HiRes
8 Bit, (HiRes up to 10 Bit)
40 ps
Sinx/x, linear, Sample-hold
Off, 50 ms…∞
0…8 Million x (1/samplerate)
0…2 Million x (1/samplerate)
Up to 2000 waveforms/s
Dots, vectors, ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…200 MHz
50 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, V top, V base,
frequency, period, pulse count,
t width+, t width-, tdutycycle+, tdutycycle, trise, t fall,
pos. edge count, neg. edge count, pos.
pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB type B/RS-232 (HO720),
Interface:
2 x USB type A (front- and rear side
each 1 x) max. 100 mA,
DVI-D for ext. Monitor
IEEE-488 (GPIB) (HO740),
Optional:
Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
Parallel
I2C
(Opt. HOO10, HOO11)
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for all
Math-, Logic-, Bus- and Reference Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
value in ASCII, binary, decimal or hexa­
decimal, up to 4 lines
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing
acknowledge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
Specifications
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
General Information
Component tester
Test voltage:
Test current:
Test frequency:
Reference Potential:
Probe ADJ Output:
Bus Signal Source
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX, LOG,
LN, Low-, High-pass filter
Up to 4 math. memories with label
Analog channels
Mask around a signal, userdefined tolerance
Stop, Beep, screen shot (screen print-out)
and/or output to printer for pass or fail,
event counting up to 4 billion, including
the number and the percentage of pass
and fail events
10 VP (open) typ.
10 mAP (short) typ.
50 Hz / 200 Hz typ.
Ground (safety earth)
1 kHz/1 MHz square wave signal ~1Vpp
(ta <4 ns)
SPI, I2C, UART, Parallel (4 Bit)
Date and time for stored data
100…240 V, 50…60 Hz, CAT II
Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W]
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 140 mm
<2.5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, 2 [4] Probes,
10:1 with attenuation ID (HZO10), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Logic channels and Analog channels
HOO11Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB) galvanically isolated
HZO91 4RU 19‘‘ Rackmount Kit
HZO90 Carrying Case for protection and transport
HZO20 High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO30 Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO50 AC/DC Current probe 20 A, DC…100 kHz
HZO51 AC/DC Current probe 1000 A, DC…20 kHz
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
Lower AC bandwidth:
Bandwidth limiter
approx. 20 MHz
(switchable):
<1.75 ns
Rise time (calculated):
2 %
DC gain accuracy:
12 calibrated steps
Input sensitivity:
CH 1, CH 2 [CH 1…CH 4] 1 mV/div.…10 V/div. (1–2–5 Sequence)
Between calibrated steps
Variable
Inputs CH 1, CH 2 [CH 1…CH 4]:
1 MΩ II 14 pF ±2 pF (50 Ω switchable)
Impedance
DC, AC, GND
Coupling
200 V (DC + peak AC), 50 Ω <5 Vrms
Max. input voltage
Measuring Category I (CAT I)
Measuring circuits:
±10 Divs
Position range:
Offset control:
±0,2 V - 10 div. x Sensitivity
1 mV, 2 mV
±1 V - 10 div. x Sensitivity
5…50 mV
±2,5 V - 10 div. x Sensitivity
100 mV
±40 V - 10 div. x Sensitivity
200 mV…2 V
±100 V - 10 div. x Sensitivity
5 V
With Option HO3508
Logic channels
Select. switching
TTL, CMOS, ECL, User -2…+8 V
­thresholds
100 kΩ || <4 pF
Impedance
DC
Coupling
40 V (DC + peak AC)
Max. input voltage
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources:
Coupling
(Analog Channel):
Video:
Standards
200 MHz 2 [4] Channel Digital Oscilloscope
HMO2022 [HMO2024]
Product description, page 8
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per trace:
Vertical System
Channels:
DSO mode
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1, CH 2 [CH 1…CH 4]
CH 1, CH 2, LCH 0…7 (logic channels)
[CH 1, CH 2, LCH 0…7, CH 4]
with Option HO3508
Frontside [Rear side]
Ext. Trigger
1 MΩ || 14 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1, CH 2 [CH 1…CH 4]
200 MHz (5 mV…10 V)/div.
100 MHz (1 mV, 2 mV)/div.
2 Hz
Fields
Line
Sync. Impulse
Sources:
Logic:
Sources:
State
Pulses:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope:
Min. signal height
Frequency range
Linking of peak detection and trigger level
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
5 Hz…250 MHz (5 Hz…120 MHz at ≤2 mV/div.)
From peak- to peak+
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…250 MHz (0 Hz…120 MHz at ≤2 mV/div.)
-10…+10 div. from center of the screen
Slope/Video/Logic/Pulses/Buses (optional)
Rising, falling, both
CH 1, CH 2, Line, Ext., LCH 0…7
[CH 1…CH 4, Line, Ext., LCH 0…7]
AC: 5 Hz…250 MHz
DC: 0…250 MHz
HF: 30 kHz…250 MHz
LF: 0…5 kHz
Noise rejection: selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
All, selectable line number
Positive, negative
CH 1, CH 2, Ext. [CH 1…CH 4]
AND, OR, TRUE, FALSE
LCH 0…7
LCH 0…7 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 32 ns, max. 10 s, resolution min. 8 ns
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ. (1.5 div. at ≤2 mV/div.)
0 Hz…250 MHz (0 Hz…120 MHz at ≤2 mV/div.)
67
Specifications
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
I2C
SPI
UART/RS-232
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Roll Mode:
Digital Storage
Sampling rate (real time):
Memory:
Operation modes:
Resolution (vertical)
Resolution (horizontal)
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
-10…+10 div.
Parallel
32 ns…10 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
I2C
(Opt. HOO10, HOO11)
Time, Frequency (FFT), Voltage (XY)
Main-window, main- and zoom-window
Up to 50,000:1
50 ppm
2 ns/div.…50 s/div.
50 ms/div.…50 s/div.
2 x 1 GSa/s, 1 x 2 GSa/s
[4 x 1 GSa/s, 2 x 2 GSa/s]
Logic channels: 8 x 1 GSa/s
2 x 1 MPts, 1 x 2 MPts
[4 x 1 MPts, 2 x 2 MPts]
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter, HiRes
8 Bit, (HiRes up to 10 Bit)
40 ps
Sinx/x, linear, Sample-hold
Off, 50 ms…∞
0…8 Million x (1/samplerate)
0…2 Million x (1/samplerate)
Up to 2000 waveforms/s
Dots, vectors, ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…250 MHz
50 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, V top, V base,
frequency, period, pulse count,
t width+, t width-, tdutycycle+, tdutycycle, trise, t fall,
pos. edge count, neg. edge count, pos.
pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB type B/RS-232 (HO720),
Interface:
2 x USB type A (front- and rear side
each 1 x) max. 100 mA,
DVI-D for ext. Monitor
IEEE-488 (GPIB) (HO740),
Optional:
Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
68
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for all
Math-, Logic-, Bus- and Reference Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
value in ASCII, binary, decimal or hexa­
decimal, up to 4 lines
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
General Information
Component tester
Test voltage:
Test current:
Test frequency:
Reference Potential:
Probe ADJ Output:
Bus Signal Source
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing acknowl­
edge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX, LOG,
LN, Low-, High-pass filter
Up to 4 math. memories with label
Analog channels
Mask around a signal, userdefined
tolerance
Stop, Beep, screen shot (screen print-out)
and/or output to printer for pass or fail,
event counting up to 4 billion, including
the number and the percentage of pass
and fail events
10 VP (open) typ.
10 mAP (short) typ.
50 Hz / 200 Hz typ.
Ground (safety earth)
1 kHz/1 MHz square wave signal ~1Vpp
(ta <4 ns)
SPI, I2C, UART, Parallel (4 Bit)
Date and time for stored data
100…240 V, 50…60 Hz, CAT II
Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W]
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 140 mm
<2.5kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, 2 [4] Probes, 10:1 with
attenuation ID (HZO10), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Logic channels and Analog channels
HOO11Serial bus trigger and hardware accelerated decode, I2C, SPI,
UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO730
Dual-Interface Ethernet/USB
HO740
Interface IEEE-488 (GPIB) galvanically isolated
HZO91
4RU 19‘‘ Rackmount Kit
HZO90
Carrying Case for protection and transport
HZO20
High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO30
Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO50
AC/DC Current probe 20 A, DC…100 kHz
HZO51
AC/DC Current probe 1000 A, DC…20 kHz
Specifications
250 MHz 4 Channel Digital Oscilloscope HMO2524
Product description, page 7
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per channel:
Vertical System
Channels:
DSO mode
MSO mode
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
Lower AC bandwidth:
Bandwidth limiter
(switchable):
Rise time (calculated):
DC gain accuracy
Input sensitivity:
CH 1…C H4
Variable
Inputs CH1…CH4:
Impedance
Coupling
Max. input voltage
Measuring circuits:
Position range
Offset control:
1 mV, 2 mV
5…50 mV
100 mV…5 V
Logic channels
Select. switching
­thresholds
Impedance
Coupling
Max. input voltage
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Sources:
Coupling:
Video:
Standards
Fields
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1…CH 4
CH 1…CH 3 LCH 0…7
(with 1x Option HO3508)
CH 1, CH 2, LCH 0…15
(with 2x Option HO3508)
Rear side
Ext. Trigger
1 MΩ || 13 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1…CH 4
250 MHz (5 mV…5 V)/div.
100 MHz (1 mV, 2 mV)/div.
2 Hz
approx. 20 MHz
<1.5 ns
2 %
12 calibrated steps
1 mV/div.…5 V/div. (1–2–5 Sequence)
Between calibrated steps
1 MΩ II 13 pF ±2 pF (50 Ω switchable)
DC, AC, GND
200 V (DC + peak AC), 50 Ω <5 Vrms
Measuring Category I (CAT I)
±10 Divs
±0.2 V
±1 V
±20 V
With Option HO3508
TTL, CMOS, ECL, 2x User -2…+8 V
100 kΩ || <4 pF
DC
40 V (DC + peak AC)
Linking of peak detection and trigger level
0.8 div; 0.5 div typ.
5 Hz…300 MHz
From peak- to peak+
0.8 div; 0.5 div typ.
0…300 MHz
-10….+10 div.
Slope/Video/Logic/Pulse/Buses (optional)
Rising, falling, both
CH 1…CH 4, Line, Ext., LCH 0…15
AC: 5 Hz…300 MHz
DC: 0…300 MHz
HF: 30 kHz…300 MHz
LF: 0…5 kHz
Noise rejection: 100 MHz LPF selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
Line
Sync. Impulse
Source
Logic:
Source
State
Pulse:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope
Min. signal height
Frequency range
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
I2C
SPI
UART/RS-232
All, selectable line number
Positive, negative
CH 1…CH 4
AND, OR, TRUE, FALSE
LCH 0…15
LCH 0…15 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 8 ns, max. 134,217 ms, resolution from
8 ns until 1 μs
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ.
0…300 MHz
-10….+10 div.
20 ns…0.1 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
Horizontal System
Time, Frequency (FFT), Voltage (XY)
Domain representation:
Representation Time Base: Main-window, main- and zoom-window
Up to 100,000:1
Memory Zoom:
15 ppm
Accuracy:
Time Base:
Refresh operating modes 2 ns/div.…20 ms/div.
50 ms/div.…50 s/div.
Roll operating modes
Digital Storage
Sampling rate (real time):
Sampling rate (random):
Memory:
Operation modes:
Resolution (vertical):
Resolution (horizontal):
Yt Mode
XY Mode
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
4 x 1.25 GSa/s, 2 x 2.5 GSa/s
Logic channels: 16 x 1.25 GSa/s
25 GSa/s (n/a to logic channels)
4 x 2 MPts, 2 x 4 MPts
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter
8 Bit
50 Pts./div.
8 Bit
Sinx/x (CH 1…CH 4), Pulse (LCH 0…15)
Off, 50 ms…∞
0…2 Million x (1/samplerate)
0…8 Million x (1/samplerate)
Up to 2500 waveforms/s
Dots, vectors (interpolation), ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…300 MHz
15 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, Vtop, Vbase,
frequency, period, pulse count,
twidth+, twidth-, tdutycycle+, tdutycycle, trise, tfall,
pos. edge count, neg. edge count,
pos. pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
69
Specifications
Cursor measurements:
Interface:
Optional:
Display functions
Marker:
VirtualScreen:
Busdisplay:
Parallel
I2C
(Opt. HOO10, HOO11)
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB/RS-232 (HO720),
USB-Stick (frontside),
USB-Printer (rear side) for Postscript
Printer, DVI-D for ext. monitor
IEEE-488 (GPIB) (HO740),
Ethernet/USB (HO730)
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for
all Math-, Logic-, Bus- and Reference
Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
value in ASCII, binary, decimal or hexa­
decimal, up to 4 lines
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing acknowl­
edge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
HZ99
HZ355
HZ355DU
HZO20
HZO30
HZO50
HZO51
Carrying Case for protection and transport
Slimline Probe 10:1 with automatic identification
Upgrade from 2x HZ350 to 2x HZ355
High voltage probe 1000:1 (400 MHz, 1000 Vrms)
Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
AC/DC Current probe 20 A, DC…100 kHz
AC/DC Current probe 1000 A, DC…20 kHz
350 MHz 2 [4] Channel Digital Oscilloscope
HMO3522 [HMO3524]
Product description, page 6
Display
Display:
Resolution:
Backlight:
Display area for traces:
without menu
with menu
Color depth:
Intensity steps per channel:
Vertical System
Channels:
DSO mode
MSO mode
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX,
LOG, LN, Low-, High-pass filter
Up to 4 math. memories with label
Auxiliary input:
Function
Impedance
Coupling
Max. input voltage
XYZ-mode:
Invert:
Y-bandwidth (-3 dB):
Analog channels
Mask around a signal, userdefined
tolerance
Stop, Beep, screen shot, (screen print-out),
output to printer and/or pulse on the
Y output for pass or fail, event counting
up to 4 billion, including the number and
the percentage of pass and fail events.
All data valid at 23 °C after 30 minute warm-up
Lower AC bandwidth:
Bandwidth limiter
(switchable):
Rise time (calculated):
DC gain accuracy
Input sensitivity:
CH 1, CH 2 [CH 1…CH 4]
Variable
Inputs CH 1, CH 2
[CH 1…CH 4]:
Impedance
Coupling
Max. input voltage
Measuring circuits:
Position range
Offset control:
1 mV, 2 mV
5…50 mV
100 mV…5 V
Logic channels
Select. switching
t­hresholds
Impedance
Coupling
Max. input voltage
Accessories supplied: Line cord, Operating manual, 4 Probes,
10:1 with attenuation ID (HZ350), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode,
I2C, SPI, UART/RS-232 on Logic channels
HOO11Serial bus trigger and hardware accelerated decode,
I2C, SPI, UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO3516 2 x HO3508, active 8 Channel Logic Probes
HO730
Dual-Interface Ethernet/USB
HO740
Interface IEEE-488 (GPIB) galvanically isolated
HZ46
4RU 19‘‘ Rackmount Kit
Triggering
Analog channels:
Automatic:
Min. signal height
Frequency range
Level control range
Normal (without peak):
Min. signal height
Frequency range
Level control range
Operating modes:
Slope:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
General Information
Probe ADJ Output:
Bus Signal Source:
Internal RTC
(Realtime clock):
Line voltage:
Power consumption:
Protective system:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
70
1 kHz/1 MHz square wave signal approx.
1 Vpp (ta <4 ns)
SPI, I2C, UART, Parallel (4 Bit)
Date and time for stored data
105…253 V, 50…60 Hz, CAT II
Max. 70 W at 230 V, 50 Hz
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 220 mm
3.6 kg
16.5 cm (6.5”) VGA Color TFT
640 x 480 Pixel
LED 400 cd/m2
400 x 600 Pixel (8 x 12 div.)
400 x 500 Pixel (8 x 10 div.)
256 colors
0…31
CH 1, CH 2 [CH 1…CH 4]
CH 1, CH 2, LCH 0…15
(logic channels) with 2 x Option HO3508
Frontside [Rear side]
Ext. Trigger
1 MΩ || 13 pF ±2 pF
DC, AC
100 V (DC + peak AC)
All analog channels on individual choice
CH 1, CH 2 [CH 1…CH 4]
350 MHz (5 mV…5 V)/div.
100 MHz (1 mV, 2 mV)/div.
2 Hz
approx. 20 MHz
<1 ns
2 %
12 calibrated steps
1 mV/div.…5 V/div. (1–2–5 Sequence)
Between calibrated steps
1 MΩ II 13 pF ±2 pF (50 Ω switchable)
DC, AC, GND
200 V (DC + peak AC), 50 Ω <5 Vrms
Measuring Category I (CAT I)
±10 Divs
±0.2 V
±1 V
±20 V
With Option HO3508
TTL, CMOS, ECL, 2 x User -2…+8 V
100 kΩ || <4 pF
DC
40 V (DC + peak AC)
Linking of peak detection and trigger level
0.8 div; 0.5 div typ.
5 Hz…400 MHz
From peak- to peak+
0.8 div; 0.5 div typ.
0…400 MHz
-10…+10 div.
Slope/Video/Logic/Pulse/Buses (optional)
Rising, falling, both
Specifications
Sources:
Coupling:
Video:
Standards
Fields
Line
Sync. Impulse
Source
Logic:
Source
State
Pulse:
Modes
Range
Sources:
Indicator for trigger action:
Ext. Trigger via:
2nd Trigger:
Slope
Min. signal height
Frequency range
Level control range
Operating modes:
after time
after incidence
Buses (Opt. HOO10):
Sources:
Buses (Opt. HOO11):
Sources:
Format
I2C
SPI
UART/RS-232
Horizontal System
Domain representation:
Representation Time Base:
Memory Zoom:
Accuracy:
Time Base:
Refresh operating
modes
Roll operating modes
Digital Storage
Sampling rate (real time):
Sampling rate (random):
Memory:
Operation modes:
Resolution (vertical):
Resolution (horizontal):
Yt Mode
XY Mode
Interpolation:
Persistence:
Delay pretrigger:
posttrigger:
Display refresh rate:
Display:
Reference memories:
CH 1, CH 2, Line, Ext., LCH 0…15
[CH 1…CH 4, Line, Ext., LCH 0…15]
AC: 5 Hz…400 MHz
DC: 0…400 MHz
HF: 30 kHz…400 MHz
LF: 0…5 kHz
Noise rejection: 100 MHz LPF selectable
PAL, NTSC, SECAM, PAL-M, SDTV 576i,
HDTV 720p, HDTV 1080i, HDTV 1080p
Field 1, field 2, both
All, selectable line number
Positive, negative
CH 1, CH 2, Ext. [CH 1…CH 4]
AND, OR, TRUE, FALSE
LCH 0…15
LCH 0…15 X, H, L
Positive, negative
equal, unequal, less than, greater than,
within/without a range
min. 8 ns, max. 134,217 ms,
resolution from 8 ns until 1 μs
CH 1, CH 2, Ext. [CH 1…CH 4]
LED
Auxiliary input 0.3 V…10 Vpp
Rising, falling, both
0.8 div.; 0.5 div. typ.
0…400 MHz
-10…+10 div.
20 ns…0.1 s
1…216
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext., LCH 0…7
[CH 1…CH 4, Ext., LCH 0…7]
I2C/SPI/UART/RS-232
CH 1, CH 2, Ext. (for Chip Select at SPI)
[CH 1…CH 4, Ext.] (for Chip Select at SPI)
hexadecimal, binary
Trigger on Start, Stop, Restart, NACK,
Address (7 or 10 Bit), Data, Address and
Data, up to 5 Mb/s
up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12,5 Mb/s
up to 8 Bit Data, up to 31 Mb/s
Time, Frequency (FFT), Voltage (XY)
Main-window, main- and zoom-window
Up to 100,000:1
15 ppm
1 ns/div.…20 ms/div.
50 ms/div.…50 s/div.
2 x 2 GSa/s, 1 x 4 GSa/s
[4 x 2 GSa/s, 2 x 4 GSa/s]
Logic channels: 16 x 1 GSa/s
50 GSa/s (n/a to logic channels)
2 x 2 MPts, 1 x 4 MPts
[4 x 2 MPts, 2 x 4 MPts]
Refresh, Average, Envelope, Peak-Detect
Roll: free run/triggered, Filter
8 Bit
50 Pts./div.
8 Bit
Sinx/x (CH 1…CH 4), Pulse (LCH 0…15)
Off, 50 ms…∞
0…2 Million x (1/samplerate)
0…8 Million x (1/samplerate)
Up to 2500 waveforms/s
Dots, vectors (interpolation), ‘persistence’
typ. 10 Traces
Operation/Measuring/Interfaces
Menu-driven (multilingual), Autoset,
Operation:
help functions (multilingual)
typ. 10 complete instrument parameter
Save/Recall memories:
settings
Frequency counter:
6 Digit resolution
0.5 Hz…350 MHz
15 ppm
Accuracy
Amplitude, standard deviation,
Auto measurements:
Vpp, Vp+, Vp-, Vrms, Vavg, V top, V base,
frequency, period, pulse count,
t width+, t width-, tdutycycle+, tdutycycle, trise, t fall,
pos. edge count, neg. edge count, pos.
pulse count, neg. pulse count, trigger
frequency, trigger period, phase, delay
∆V, ∆t, 1/∆t (f), V to Gnd, Vt related to
Cursor measurements:
Trigger point, ratio X and Y, pulse count,
peak to peak, peak+, peak-, mean value,
RMS value, standard deviation
Dual-Interface USB/RS-232 (HO720),
Interface:
USB-Stick (frontside),
USB-Printer (rear side) for Postscript
Printer, DVI-D for ext. monitor
IEEE-488 (GPIB) (HO740),
Optional:
Ethernet/USB (HO730)
Display functions
Marker:
VirtualScreen:
Busdisplay:
Parallel
I2C
(Opt. HOO10, HOO11)
SPI
(Opt. HOO10, HOO11)
UART/RS-232
(Opt. HOO10, HOO11)
Mathematic functions
Number of formula sets:
Sources:
Targets:
Functions:
Display:
Pass/Fail functions
Sources:
Type of test:
Functions:
up to 8 user definable marker for easy
navigation
virtual Display with 20 div. vertical for
all Math-, Logic-, Bus- and Reference
Signals
up to 2 buses, user definable, parallel or
serial buses (option), decode of the bus
value in ASCII, binary, decimal or
hexadecimal, up to 4 lines
logic channels can also be used as source
for bus definition
color coded Read-, Write Address, Data,
Start, Stop, acknowledge, missing
acknowledge, Errors and Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
color coded Data, Start, Stop, Errors and
Trigger condition
5 formula sets with up to 5 formulas each
All channels and math. memories
Math. memories
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV, INTG, DIFF, SQR, MIN, MAX,
LOG, LN, Low-, High-pass filter
Up to 4 math. memories with label
Analog channels
Mask around a signal, userdefined
tolerance
Stop, Beep, screen shot (screen print-out)
and/or output to printer for pass or fail,
event counting up to 4 billion, including
the number and the percentage of pass
and fail events
General Information
Probe ADJ Output:
1 kHz/1 MHz square wave signal approx
1 Vpp (ta < 4ns)
SPI, I2C, UART, Parallel (4 Bit)
Bus Signal Source:
Internal RTC (Realtime clock): Date and time for stored data
105…253 V, 50…60 Hz, CAT II
Line voltage:
Max. 70 W at 230 V, 50 Hz
Power consumption:
Safety class I (EN61010-1)
Protective system:
+5…+40 °C
Operating temperature:
-20…+70 °C
Storage temperature:
5…80 % (non condensing)
Rel. humidity:
285 x 175 x 220 mm
Dimensions (W x H x D):
3.6 kg
Weight:
71
Specifications
All data valid at 23 °C after 30 minute warm-up.
Accessories supplied: Line cord, Operating manual, 2 [4] Probes,
10:1 with attenuation ID (HZ350), CD, Software
Recommended accessories:
HOO10Serial bus trigger and hardware accelerated decode,
I2C, SPI, UART/RS-232 on Logic channels
HOO11Serial bus trigger and hardware accelerated decode,
I2C, SPI, UART/RS-232 on Analog channels
HO3508 Active 8 Channel Logic Probe
HO3516 2 x HO3508, active 8 Channel Logic Probes
Dual-Interface Ethernet/USB
HO730
Interface IEEE-488 (GPIB) galvanically isolated
HO740
4RU 19‘‘ Rackmount Kit
HZ46
HZ99
Carrying Case for protection and transport
Slimline Probe 10:1 with automatic identification
HZ355
HZ355DU Upgrade from 2 x HZ350 to 2 x HZ355
High voltage probe 1000:1 (400 MHz, 1000 Vrms)
HZO20
Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
HZO30
AC/DC Current probe 20 A, DC…100 kHz
HZO50
HZO51
AC/DC Current probe 1000 A, DC…20 kHz
1 GHz Spectrum Analyzer HMS1000E
Product description, page 15
Frequency
100 kHz…1 GHz
Frequency range:
±2 ppm (0…30 °C)
Temperature stability:
±1 ppm/year
Aging:
0 Hz (zero span) and 1 MHz…1 GHz
Span setting range:
Spectral purity, SSB phase noise:
100 kHz from carrier
<-100 dBc/Hz
(500M Hz, +20…30 °C)
1 MHz from carrier
<-120 dBc/Hz
(500MHz, +20…30 °C)
Sweep time:
20 ms…100 s
Span = 0 Hz
20 ms…1000 s, min. 20 ms/600 MHz
Span > 0 Hz
Resolution bandwidths (-3 dB): 10 kHz…1 MHz in 1–3 steps, 200 kHz
Tolerance:
±5 % typ.
≤300kHz
±10 % typ.
1MHz
1 kHz…1 MHz in 1–3 steps
Video bandwidths:
Amplitude
Display range:
Average noise level displayed up to
+20 dBm
Amplitude measurement
Typ. -104…+20 dBm
range:
Max. permissible DC
80 V
at HF input:
20 dBm, 30 dBm for max. 3 Min.
Max. power at HF input:
Intermodulation free range:
TOI products, 2x -20 dBm 66 dB typ.
(-10 dBm ref. level)
(typ. +13 dBm third-order intercept)
(at distance between
signals ≤2 MHz)
60 dB typ. (+10 dBm TOI)
(at distance between
signals >2 MHz)
66 dB typ. (typ. +13 dBm TOI)
DANL (Displayed average noise level):
(RBW 10 kHz, VBW 1 kHz,
ref. level ≤-30 dBm
10 MHz…1 GHz)
-95 dBm, typ. -104 dBm
Inherent spurious:
(ref. level ≤-20 dBm,
f >30 MHz, RBW ≤100 kHz) <-80 dBm
Input related spurious:
(Mixer level ≤-40 dBm,
carrier offset >1 MHz)
-70 dBc typ.
2nd harmonic receive frequency:
(mixer level -40 dBm)
-60 dBc typ.
Level display:
-80…+20 dBm in 1 dB steps
Reference level
72
Display range
Logarithmic display
scaling
Measured curves:
Trace mathematics:
Detectors:
Failure of level display:
(ref. level -50 dBm, 20…30 °C)
Marker/Deltamarker
Number of marker:
Marker functions:
Marker displays:
Inputs/Outputs
HF Input
Input Impedance:
VSWR (10 MHz…1 GHz):
Trigger input:
Trigger voltage
Ext. reference input/output:
Reference frequency
Essential level (50 Ω)
Supply output for field
probes:
Audio output (Phone):
Demodulation
Miscellaneous
Display:
Save/Recall memory:
Trigger:
Interfaces:
Power supply:
Power consumption:
Protection class:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
100 dB, 50 dB, 20 dB, 10 dB
dBm, dBµV, dBmV
1 curve and 1 memory curve
A-B (curve-stored curve), B-A
Auto-, Min-, Max-Peak, Sample, RMS,
Average
<1.5 dB, typ. 0.5 dB
8
Peak, next peak, minimum,
center = marker, frequency,
reference level = marker level,
all marker on peak
Normal (level & log.), delta marker,
noise marker
N socket
50 Ω
<1.5 typ.
BNC female
TTL
BNC females
10 MHz
10 dBm
6 Vdc, max. 100 mA (2.5 mm DIN jack)
3.5 mm DIN jack
AM and FM (internal speaker)
16.5 cm (6.5“) TFT Color VGA Display
10 complete device settings
Free run, Single Trigger, external Trigger
Dual-Interface USB/RS-232 (HO720),
USB-Stick (frontside),
USB-Printer (rear side)
105…253 V, 50…60 Hz, CAT II
Max. 40 W at 230 V, 50 Hz
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 220 mm
3.6 kg
All data valid at 23 °C after 30 minute warm-up.
Accessories supplied: Line cord, Operating manual, HZ21 Adapter plug,
N plug to BNC socket, CD, Software
Recommended accessories:
Dual-Interface Ethernet/USB
HO730
HO740
Interface IEEE-488 (GPIB), galvanically isolated
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ20
Adapter, BNC to 4 mm banana
HZ33
Test cable 50 Ω, BNC/BNC, 0.5 m
HZ34
Test cable 50 Ω, BNC/BNC, 1 m
HZ46
4RU 19‘‘ Rackmount Kit
HZ72
GPIB-Cable 2 m
HZ99
Carrying Case for protection and transport
HZ520
Plug-in Antenna with BNC connection
HZ525
50 Ω-Termination, N plug
HZ530
Near-Field Probe Set 1 GHz for EMV diagnostics
HZ540/550
Near-Field Probe Set 3 GHz for EMV diagnostics
HZ540L/550L Near-Field Probe Set 3 GHz for EMV diagnostics
HZ560
Transient limiter
HZ575
75/50 Ω Converter
HZO30
active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
Specifications
1 GHz Spectrum Analyzer HMS1000, HMS1010 (with TG)
[3 GHz Spectrum Analyzer HMS3000, HMS3010 (with TG)]
Marker/Deltamarker
Number of marker:
Marker functions:
Product description, page 14
Frequency
Frequency range:
100 kHz…1 GHz
HMS1000, HMS1010
100 kHz…3 GHz
HMS3000, HMS3010
±2 ppm (0…30 °C)
Temperature stability:
±1 ppm/year
Aging:
Frequency counter*:
1 Hz
Resolution
±(Frequency x tolerance of reference)
Accuracy
Span setting range:
0 Hz (zero span) and 100 Hz…1 GHz
HMS1000, HMS1010
0 Hz (zero span) and 100 Hz…3 GHz
HMS3000, HMS3010
Spectral purity, SSB phase noise:
30 kHz from carrier
<-85 dBc/Hz
(500 MHz, +20…30 °C)
100 kHz from carrier
<-100 dBc/Hz
(500M Hz, +20…30 °C)
1 MHz from carrier
<-120 dBc/Hz
(500MHz, +20…30 °C)
Sweep time:
20 ms…100 s
Span = 0 Hz
20 ms…1000 s, min. 20 ms/600 MHz
Span > 0 Hz
100 Hz…1 MHz in 1–3 steps,
Resolution bandwidths
200 kHz
(-3 dB):
Tolerance:
±5 % typ.
≤300 kHz
±10 % typ.
1 MHz
Resolution bandwidths
200 Hz, 9 kHz, 120 kHz, 1 MHz
(-6 dB):
10 Hz…1 MHz in 1–3 steps
Video bandwidths:
Amplitude
Display range:
Average noise level displayed up to
+20 dBm
Amplitude measurement
Typ. -114…+20 dBm
range:
Max. permissible DC
80 V
at HF input:
20 dBm, 30 dBm for max. 3 Min.
Max. power at HF input:
Intermodulation free range:
TOI products, 2 x -20 dBm 66 dB typ.
(-10 dBm ref. level)
(typ. +13 dBm third-order intercept)
(at distance between
signals ≤2 MHz)
60 dB typ. (+10 dBm TOI)
(at distance between
signals >2 MHz)
66 dB typ. (typ. +13 dBm TOI)
DANL (Displayed average noise level):
(RBW 100 Hz, VBW 10 Hz,
ref. level ≤-30 dBm
10 MHz…1 GHz resp. 3 GHz) -115 dBm, typ. -124 dBm
With Preamp.
-135 dBm typ.
Inherent spurious:
(ref. level ≤-20 dBm,
f >30 MHz, RBW ≤100 kHz) <-80 dBm
Input related spurious:
(Mixer level ≤-40 dBm,
carrier offset >1 MHz)
-70 dBc typ., [-55 dBc (2…3 GHz)]
2nd harmonic receive frequency:
(mixer level -40 dBm)
-60 dBc typ.
Level display:
-80…+20 dBm in 1 dB steps
Reference level
100 dB, 50 dB, 20 dB, 10 dB, linear*
Display range
Logarithmic
dBm, dBµV, dBmV
display scaling
Percentage of reference level*
Linear display scaling
1 curve and 1 memory curve
Measured curves:
A-B (curve-stored curve), B-A
Trace mathematics:
Auto-, Min-, Max-Peak, Sample, RMS,
Detectors:
Average, Quasi-Peak
<1.5 dB, typ. 0.5 dB
Failure of level display:
(ref. level -50 dBm, 20…30 °C)
Marker displays:
Inputs/Outputs
HF Input
Input Impedance:
VSWR
(10 MHz…1 GHz/3 GHz):
Output tracking generator:
(HMS1010/HMS3010)
Output Impedance:
Frequency range:
Output level:
Trigger input:
Trigger voltage
Ext. reference input/output:
Reference frequency
Essential level (50 Ω)
Supply output for field
probes:
Audio output (Phone):
Demodulation
Miscellaneous
Display:
Save/Recall memory:
Trigger:
Interfaces:
Power supply:
Power consumption:
Protection class:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
8
Peak, next peak, minimum,
center = marker, frequency,
reference level = marker level,
all marker on peak
Normal (level, lin. & log.), delta marker,
noise marker, (frequency) counter*
N socket
50 Ω
<1.5 typ.
N socket
50 Ω
5 MHz…1 GHz [3 GHz]
-20…0 dBm, in 1 dB steps
BNC female
TTL
BNC females
10 MHz
10 dBm
6 Vdc, max. 100 mA (2.5 mm DIN jack)
3.5 mm DIN jack
AM and FM (internal speaker)
16.5 cm (6.5“) TFT Color VGA Display
10 complete device settings
Free run, Video Trigger*, Single Trigger,
external Trigger
Dual-Interface USB/RS-232 (HO720),
USB-Stick (frontside),
USB-Printer (rear side),
DVI-D for ext. monitor
105…253 V, 50…60 Hz, CAT II
Max. 40 W at 230 V, 50 Hz
Safety class I (EN61010-1)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 175 x 220 mm
3.6 kg
All data valid at 23 °C after 30 minute warm-up
*from 02.2012
Accessories supplied: Line cord, Operating manual, HZ21 Adapter plug,
N-plug to BNC socket (2x HMS1010/3010), CD, Software
Recommended accessories:
HO730
Dual-Interface Ethernet/USB
HO740
Interface IEEE-488 (GPIB), galvanically isolated
HO3011
Preamplifier -135 dBm DANL (100 Hz RBW)
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ20
Adapter, BNC to 4 mm banana
HZ33
Test cable 50 Ω, BNC/BNC, 0.5 m
HZ34
Test cable 50 Ω, BNC/BNC, 1 m
HZ46
4RU 19‘‘ Rackmount Kit
HZ72
GPIB-Cable 2 m
HZ99
Carrying Case for protection and transport
HZ520
Plug-in Antenna with BNC connection
HZ525
50 Ω-Termination, N plug
HZ530
Near-Field Probe Set 1 GHz for EMC diagnostics
HZ540/550
Near-Field Probe Set 3 GHz for EMC diagnostics
HZ540L/550L Near-Field Probe Set 3 GHz for EMC diagnostics
HZ547
3 GHz VSWR Bridge for HMS1010, HMS3010
Transient limiter
HZ560
HZ575
75/50 Ω Converter
HZO30
Active probe 1 GHz (0.9 pF, 1 MΩ, including many accessories)
73
Specifications
Triple Power Supply HM7042-5
Product description, page 24
Outputs
2 x 0…32 V/2 A and
0…5.5 V/5A
Channel 1+3 (32 V)
Range:
ON/OFF pushbutton control, SMPS fol­
lowed by a linear regulator, floating outputs
for parallel/serial operation, current limit
and electronic fuse.
Arbitrary Power Supply HM8143
2 x 0…32V, continuously adjustable 2 knobs
(coarse / fine)
≤100 µVrms (3 Hz…300 kHz)
max. 2 A
Ripple:
Current:
Current limit/
0…2 A, continuously adjustable (knob)
electronic fuse:
Recovery time (10…90 % load variation)
80 µs within ±1 mV of nominal value
30 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation: typ. 75 mV
Recovery time (50 % basic load, 10 % load variation)
30 µs within ±1 mV of nominal value
5 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation: typ. 17 mV
Display
32.00V (4 digit) / 2.000 A (4 digit)
7-segment LED:
0.01 V/1 mA
Resolution:
±3 digit voltage / ±4 digit current
Display accuracy:
indicates current limit
LED:
Channel 2 (5.5 V)
0…5.5 V, continuously adjustable (knobs)
Range:
≤100 µVrms (3 Hz…300 kHz)
Ripple:
max. 5 A
Current:
Current limit/electronic
0…5 A, continuously adjustable (knob)
fuse:
Recovery time (10…90 % load variation):
80 µs within ±1 mV of nominal value
10 µs within ±100 mV of nominal value
Max. transient deviation: typ. 170 mV
Recovery time (50 % basic load, 10 % load variation):
30 µs within ±1 mV of nominal value
15 µs within ±10 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation: typ. 60 mV
Display
5.50 V (3 digit)/5 A (3 digit)
7-segment LED:
0.01 V/10 mA
Resolution:
±3 digit voltage/±1 digit current
Display accuracy:
indicates current limit
LED:
Maximum ratings
Max. voltage applicable to output terminals:
CH 1 + CH 3:
33 V
CH 2:
6 V
max. 0.4 V
Reverse voltage:
max. 5 A
Reverse current:
max. 150 V
Voltage to earth:
Miscellaneous
Safety class:
Mains supply:
Mains Fuse:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
Safety class I (EN61010-1)
115/230 V ±10 %; 50…60 Hz, CAT II
115 V: 2 x 5 A slow blow 5 x 20 mm
230 V: 2 x 2.5 A slow blow 5 x 20 mm
max. 330 VA/250 W
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 7.4 kg
All data valid at 23 °C after 30 minutes warm-up.
74
Accessories supplied: Operating manual, line cord, CD
Recommended accessories:
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
HZ42
19’’ Rackmount Kit 2RU
Product description, page 25
Outputs
2 x 0…30 V/2 A
1 x 5 V/2 A
On/off pushbutton control, Floating
outputs (allowing parallel and series
operation), current limit, electronic fuse,
tracking mode
Channels 1+3 (0…30 V)
2 x 0…30 V
Output voltage:
10 mV
Setting resolution:
±3 digits (typ. ±2 digit)
Setting accuracy:
±3 digits (typ. ±2 digit)
Measurement accuracy:
<5 mVrms (3 Hz…300 kHz)
Residual ripple:
Recovery time (10…90 % load variation)
45 µs within ±1 mV of nominal value
16 µs within ±100 mV of nominal value
Max. transient deviation: typ. 800 mV
Recovery time (50 % basic load, 10 % load variation)
30 µs within ±1 mV of nominal value
10 µs within ±100 mV of nominal value
Max. transient deviation: typ. 120 mV
Compensation of lead
up to 300 mV
resistances (SENSE):
2 x 0…2 A
Output current:
1 mA
Setting resolution:
±3 digits (typ. ±2 digit)
Setting accuracy:
±3 digits (typ. ±2 digit)
Measurement accuracy:
<100 µs
Recovery time:
Channel 2 (5 V)
5 V ±50 mV
Accuracy:
max. 2 A
Output current:
≤100 µVrms (3 Hz…300 kHz)
Ripple:
Recovery time (10…90 % load variation)
30 µs within ±1 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation: typ. 60 mV
Recovery time (50 % basic load, 10 % load variation)
30 µs within ±1 mV of nominal value
0 µs within ±100 mV of nominal value
Max. transient deviation: typ. 20 mV
Arbitrary Function (Channel 1 only)
max. 4096
Number of points:
12 Bit
Resolution:
Dwell time and Voltage
Parameters of points:
100 µs…60 s
Dwell time:
1…255 and continuous
Repetition rate:
Inputs:
Modulation input
(BNC socket):
Accuracy:
Modulation bandwidth
(-3 dB):
Slew rate (dV/dt):
Trigger input (BNC socket):
Level:
0…10 V
1 % of full scale
>50 kHz
1 V/µs
Triggering the arbitrary function
TTL
Miscellaneous
Max. voltage applicable to output terminals
30 V
CH 1 + CH 3:
5 V
CH 2:
max. 150 V
Voltage to earth:
Specifications
Display:
Interface:
Protection class:
Power supply:
Mains fuse:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
4 x 4-digit 7-segment LEDs
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
I acc. to EN 61010 (IEC 61010)
with protective earth
115/230 V ±10 %; 50…60 Hz, CAT II
115 V: 2 x 6 A slow blow 5 x 20 mm
230 V: 2 x 3.15 A slow blow 5 x 20 mm
approx. 300 VA
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 9 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Operating manual, line cord, CD, Software
Recommended accessories:
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
Interface cable (USB) 1.8 m
HZ13
HZ14
Interface cable (serial) 1:1
19’’ Rackmount Kit 2RU
HZ42
GPIB-Cable 2 m
HZ72
Programmable 2 Channel High Performance Power Supply HMP2020
[Programmable 3 Channel High Performance Power Supply HMP2030]
Product description, page 23
Outputs
Advanced parallel and series operation: simultaneous switching on/off of
­active channels via “Output” button, common voltage- and current con­
trol using tracking mode (individual channel linking), individual mapping
of channels which shall be affected by FuseLink overcurrent protection
(switch-off), all channels galvanically isolated from each other and the
protective earth.
HMP2020
HMP2030
Output terminals:
Output power:
Compensation of lead
resistances (Sense):
Overvoltage/overcurrent
protection (OVP/OCP):
Electronic fuse:
Response time:
32 V channels
Output values:
HMP2020
HMP2030
Resolution:
Voltage
Current HMP2030
Current HMP2020
Setting accuracy:
Voltage
Current HMP2030
Current HMP2020
Current HMP2020
Measurement accuracy:
Voltage
1 x 0…32 V/0…10 A
1 x 32 V/0…5 A
3 x 0…32 V/0…5 A
4 mm safety sockets frontside, Screw-type
terminal rear side (4 units per channel)
188 W max.
1 V
Adjustable for each channel
Adjustable for each channel,
may be combined using FuseLink
<10 ms
1 x 0…32 V/0…10 A, (5 A at 32 V, 160 W max.)
1 x 0…32 V/0…5 A, (2,5 A at 32 V, 80 W max.)
3 x 0…32 V/0…5 A, (2.5 A at 32 V, 80 W max.)
1 mV
<1 A: 0.1 mA; ≥1 A: 1 mA
<1 A: 0.2 mA; ≥1 A: 1 mA,
(10 A Channel, CH 1)
<1 A: 0,2 mA; ≥1 A: 1 mA,
(5 A Channel, CH 2)
<0.05 % + 5 mV (typ. ±2 mV)
<0.1 % + 5 mA (typ. ±0.5 mA at I <500 mA)
<0.1 % + 5 mA (typ. ±1 mA at I <500 mA),
(10 A Channel, CH 1)
<0.1 % + 5 mA (typ. ±0,5 mA at I <500 mA),
(5 A Channel, CH 2)
Current HMP2030
Current HMP2030
Current HMP2020
<500 mA: <0.05 % + 0.5 mA, typ. ±0.2 mA
≥500 mA: <0.05 % + 2 mA, typ. ±1 mA
<500 mA: <0,05 % + 0,5 mA, typ. ±0,5 mA,
(10 A Channel, CH 1)
<500 mA: <0,05 % + 0,5 mA, typ. ±0,2 mA,
Current HMP2020
(5 A Channel, CH 2)
≥500 mA: <0,05 % + 2 mA, typ. ±2 mA,
Current HMP2020
(10 A Channel, CH 1)
≥500 mA: <0,05 % + 2 mA, typ. ±1 mA,
Current HMP2020
(5 A Channel, CH 1)
3 Hz…100 kHz
3 Hz…20 MHz
Residual ripple
<150 µVrms
1.5 mVrms typ.
Voltage
<1 mArms
Current
Residual deviation after a load change (10…90 %):
<0.01 % + 2 mV
Voltage
<0.01 % + 250 µA
Current
Residual deviation after a line voltage change (±10 %):
<0.01 % + 2 mV
Voltage
<0.01 % + 250 µA
Current
Recovery time after a load
step from 10…90 % for return
<100 µs
within a ±10 mV window:
Arbitrary Function EasyArb
Voltage, current, time
Parameters of points:
128
Number of points:
10 ms…60 s
Dwell time:
Continuous or burst mode with
Repetition rate:
1…255 repetitions
Manually via keyboard or via Interface
Trigger:
Maximum ratings
Reverse voltage:
Reverse polarized voltage:
Max. permitted current in
case of reverse voltage:
Voltage to earth:
Miscellaneous
Temperature coefficient /°C:
Voltage
Current
Display:
Memory:
Interface:
Processing time:
Protection class:
Power supply:
Mains fuses:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
33 V max.
0.4 V max.
5 A max.
150 V max.
0.01 % + 2 mV
0.02 % + 3 mA
240 x 64 Pixel LCD (full graphical)
Non volatile memory for 3 Arbitrary
functions and 10 device settings
Dual-Interface USB/RS-232 (HO720)
<50 ms
Safety class I (EN61010-1)
115/230 V±10 %; 50…60 Hz, CAT II
5 x 20 mm slow blow
115 V: 2 x 6 A
230 V: 2 x 3.15 A
350 VA max.
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
8,5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD, Software
Recommended accessories:
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB), galvanically isolated
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ42
2RU 19’’ Rackmount Kit
HZ72
GPIB-Cable 2 m
<0.05 % + 2 mV
75
Specifications
Programmable 3 Channel High Performance Power Supply HMP4030
[Programmable 4 Channel High Performance Power Supply HMP4040]
Protection class:
Power supply:
Mains fuses:
Product description, page 22
Outputs
Advanced parallel and series operation: simultaneous switching on/off of
­active channels via “Output” button, common voltage- and current con­
trol using tracking mode (individual channel linking), individual mapping
of channels which shall be affected by FuseLink overcurrent protection
(switch-off), all channels galvanically isolated from each other and the
protective earth.
HMP4030
HMP4040
Output terminals:
Output power:
Compensation of lead
resistances (Sense):
Overvoltage/overcurrent
protection (OVP/OCP):
Electronic fuse:
Response time:
3 x 0…32 V/0…10 A
4 x 0…32 V/0…10 A
4 mm safety sockets frontside, Screw-type
terminal rear side (4 units per channel)
384 W max.
1 V
Adjustable for each channel
Adjustable for each channel,
may be combined using FuseLink
<10 ms
32 V channels
Output values:
3 x 0…32 V/0…10 A, (5 A at 32 V, 160 W max.)
HMP4030
4 x 0…32 V/0…10 A, (5 A at 32 V, 160 W max.)
HMP4040
Resolution:
1 mV
Voltage
<1 A: 0.2 mA; ≥1 A: 1 mA
Current
Setting accuracy:
<0.05 % + 5 mV (typ. ±2 mV)
Voltage
<0.1 % + 5 mA (typ. ±1 mA at I <500 mA)
Current
Measurement accuracy:
<0.05 % + 2 mV
Voltage
<500 mA: <0.05 % + 1 mA, typ. ±0.5 mA
Current
≥500mA: <0.05 % + 2 mA, typ. ±2 mA
Current
3 Hz…100 kHz
3 Hz…20 MHz
Residual ripple
<150 µVrms
1.5 mVrms typ.
Voltage
<1 mArms
Current
Residual deviation after a load change (10…90 %):
<0.01 % + 2 mV
Voltage
<0.01 % + 250 µA
Current
Residual deviation after a line voltage change (±10 %):
<0.01 % + 2 mV
Voltage
<0.01 % + 250 µA
Current
Recovery time after a load
step from 10…90 % for return
<100 µs
within a ±10 mV window:
Arbitrary Function EasyArb
Voltage, current, time
Parameters of points:
128
Number of points:
10 ms…60 s
Dwell time:
Continuous or burst mode
Repetition rate:
with 1…255 repetitions
Manually via keyboard or via Interface
Trigger:
Maximum ratings
Reverse voltage:
Reverse polarized voltage:
Max. permitted current in
case of reverse voltage:
Voltage to earth:
Miscellaneous
Temperature coefficient/°C:
Voltage
Current
Display:
Memory:
Interface:
Processing time:
76
33 V max.
0.4 V max.
5 A max.
150 V max.
0.01 % + 2 mV
0.02 % + 3 mA
240 x 128 Pixel LCD (full graphical)
Non volatile memory for 3 Arbitrary
functions and 10 device settings
Dual-Interface USB/RS-232 (HO720)
<50 ms
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
Safety class I (EN61010-1)
115/230 V±10 %; 50…60 Hz, CAT II
5 x 20 mm slow blow
115 V: 2 x 10 A
230 V: 2 x 5 A
550 VA max.
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 125 x 365 mm
approx. 10 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD, Software
Recommended accessories:
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB), galvanically isolated
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ43
19’’ Rackmount Kit 3RU
HZ72
GPIB-Cable 2 m
HZP91 19’’ Rackmount Kit 4RU
6½-Digit Precision Multimeter HM8112-3
Product description, page 29
DC specifications
Ranges:
Input impedance
0.1 V, 1.0 V:
10 V, 100 V, 600 V:
Accuracy:
Range
0,1 V
1,0 V
10,0 V
100,0 V
600,0 V
1 year;
% rdg.
0,005
0,003
0,003
0,003
0,004
Integration time:
Display range:
600 V range:
Resolution:
Zero point
Temperature drift:
Long-term stability:
AC specifications
Measurement ranges:
Measurement method:
0.1 V; 1 V; 10 V; 100 V; 600 V
>1 GΩ
10 MΩ
Values given are in ±(% of reading (rdg.)
+ % of full scale (f.s.))
23 °C ±2 °C
% f.s.
0,0006
0,0006
0,0006
0,0006
0,0006
Temp. coefficient
10…21 °C + 25…40 °C
0,0008
0,0008
0,0008
0,0008
0,0008
0.1 s
120.000 digit
60.000 digit
1 µV
1…60 s
1,200.000 digit
600.000 digit
100 nV
better than 0.3 µV/°C
better than 3 µV for 90 days
0.1 V; 1 V; 10 V; 100 V; 600 V
true rms, DC or AC coupled
(not in 0.1 V range)
Input impedance:
1 GΩ II <60 pF
0.1 V, 1 V:
10 MΩ II <60 pF
10…600 V:
1.5 sec to within 0.1 % of reading
Response time:
For sine wave signals >5 % of full scale
Accuracy:
Values given are in ±(% of reading + % of full scale); 23 °C ±2 °C for 1 year
Range 20 Hz…1 kHz 1…10 kHz 10…50 kHz 50…100 kHz 100…300 kHz
0.1 V
0.1+0.08 5+0.5 (5 kHz)
1.0 V
0.08+0.08
0.15+0.08
0.3+0.1
0.8+0.15
7+0.15
10.0 V
0.08+0.08
0.1+0.08
0.3+0.1
0.8+0.15
4+0.15
100.0 V
0.08+0.08
0.1+0.08
0.3+0.1
0.8+0.15
600.0 V
0.08+0.08
0.1+0.08
Specifications
Temperature coefficient 10…21 °C and 25…40 °C; (% rdg. + % f.s.)
0.01 + 0.008
at 20 Hz…10 kHz:
0.08 + 0.01
at 10…100 kHz:
7:1 (max. 5x range)
Crest factor:
0.1s
1…60s
Integration time:
1,200.000 digit
120.000 digit
Display range:
600.00 digit
600.000 digit
600 V range:
100 nV
1 µV
Resolution:
Overload protection:
(V/Ω-HI to V/Ω-LO) and to chassis:
all
Measurement ranges:
all the time
850 Vpeak or 600 Vdc
Maximum input voltage LOW against
250 Vrms at max. 60 Hz or 250 Vdc
chassis/safety earth:
Current specifications
Ranges:
Integration time:
Display ranges:
1 A range:
Resolution:
Accuracy:
(1 year; 23 °C ±2 °C)
Temperature coefficient/°C:
(%rdg. + %f.s.)
Voltage:
Response time:
Crest factor:
Input protection:
Resistance
Ranges:
Integration time:
Display ranges:
Resolution:
Accuracy:
Range
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 µA; 1 mA; 10 mA; 100 mA; 1 A
0.1 s
1…60 s
120.000 digit
1,200.000 digit
100.000 digit
1,000.000 digit
1 nA
100pA
DC
45 Hz…1 kHz
1…5 kHz
0.02 + 0.002 0.1 + 0.08
0.2 + 0.08
10…21 °C
25…40 °C
0.002+ 0.001
0.01+ 0.01
<600 mV…1.5 V
1.5 s to within 0.1 % of reading
7:1 (max. 5 x range)
fuse, FF 1 A 250 V
100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ
0.1 s
1…60 s
120.000 digit
1,200.000 digit
1 mΩ
100 µΩ
Values given are in
±(% of reading + % of full scale)
1 year;
%rdg
0.005
0.005
0.005
0.005
0.05
0.5
Measurement current:
23 °C ±2 °C
%f.s.
0.0015
0.001
0.001
0.001
0.002
0.02
Temp. coefficient/°C
10…21 °C
25…40 °C
0.0008
0.0008
0.0008
0.0008
0.0008
0.0008
0.0008
0.0008
0.002
0.002
0.01
0.01
Range
100 Ω, 1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
Current
1 mA
100 µA
10 µA
1 µA
100 nA
max. measurement voltage: approx. 3 V
250 Vp
Overload protection:
Temperature measurement
2- and 4-wire measurement
PT100/PT1000 (EN60751):
-200…+800 °C
Range:
0.01 °C; measurement current 1 mA
Resolution:
±(0.05 °C + sensor tolerance + 0.08 K)
Accuracy:
Temperature coefficient
10…21 °C and 25…40 °C: <0.0018 °C/°C
NiCr-Ni (K-type)
-270…+1,372 °C
Range:
0.1 °C
Resolution:
±(0.7 % rdg. + 0.3 K)
Accuracy:
NiCr-Ni (J-type)
-210…+1,200 °C
Range:
0.1 °C
Resolution:
±(0.7 % rdg. + 0.3 K)
Accuracy:
Frequency and period specifications
1 Hz…100 kHz
Range:
0.00001…1 Hz
Resolution:
0.05 % of reading
Accuracy:
1…2 s
Measurement time:
Interface
Interface:
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
Control / Data fetch
Function, range, integration time, start
command
Measurement results, function, range,
integration time (10 ms…60 s)
Functions:
Inputs:
Outputs:
Miscellaneous
Time to change range or function
approx. 125 ms with DC voltage, DC current,
resistance approx. 1 s with AC voltage,
AC current
30,000 readings /128 kB
Memory:
Safety class I (EN 61010)
Safety class:
105…254 V~; 50…60 Hz, CAT II
Power supply:
approx. 8 W
Power consumption:
+5…+40 °C
Operating temperature:
-20…+70 °C
Storage temperature:
5…80 % (non condensing)
Rel. humidity:
285 x 75 x 365 mm
Dimensions (W x H x D):
approx. 3 kg
Weight:
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, PVC test lead (HZ15),
Interface cable (HZ14), CD
Recommended accessories:
HO112 Scanner Card (Installation only ex factory) as HM8112-3S
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ10S 5 x Silicone test lead black
HZ10R 5 x Silicone test lead red
HZ10B 5 x Silicone test lead blue
HZ13
Interface cable (USB) 1.8 m
Test cable 50 Ω, BNC/BNC, 0.5 m
HZ33
HZ34
Test cable 50 Ω, BNC/BNC, 1 m
HZ42
19” Rackmount kit 2RU
GPIB-Cable 2 m
HZ72
HZ887 Temperature probe
8 kW Power Meter HM8115-2
Product description, page 30
Voltage
Ranges:
Resolution:
Accuracy:
Input impedance:
Crest factor:
Input protection:
Current
Ranges:
Resolution:
Accuracy:
Crest factor:
Input protection:
True RMS voltage measurement (AC + DC)
50 V
150 V
500 V
0.1 V
1 V
1 V
20 Hz…1 kHz:
±(0.4 % + 5 digit)
DC:
±(0.6 % + 5 digit)
1 MΩ II 100 pF
max. 3.5 at full scale
max. 500 Vp
True RMS current measurement (AC + DC)
160 mA
1.6 A
16 A
1 mA
1 mA
10 mA
20 Hz…1 kHz:
±(0.4 % + 5 digit)
DC:
±(0.6 % + 5 digit)
max. 4 at full scale
fuse, FF 16A 6.3 x 32mm (superfast)
Active power measurement
The measurement range is the product of the selected voltage respective
current ranges.
Ranges:
8 W
24 W
80 W 240 W 800 W 2400 W 8000 W
Resolution:
1 mW 10 mW 10 mW 100 mW 100 mW
1 W
1 W
20 Hz…1 kHz:
±(0.8 % + 10 digit)
Accuracy:
DC:
±(0.8 % + 10 digit)
4-digit, 7-segment LED
Display:
Reactive power measurement
Ranges:
8 var
24 var
80 var 240/800 var 2400/8000 var
Resolution: 10 mvar 100 mvar 100 mvar
1 var
1 var
77
Specifications
Accuracy:
Display:
20…400 Hz: ±(2.5 % + 10 digit + 0.02 x P)
P = active power
4-digit, 7-segment LED
Apparent power measurement
Ranges:
8 VA
24 VA
80 VA 240/800 VA 2400/8000 VA
10 mVA
100 mVA
1 VA
Resolution: 1 mVA 10 mVA
±(0.8 % + 5 digit)
20 Hz…1 kHz:
Accuracy:
4-digit, 7-segment LED
Display:
Power factor measurement
0.00…+1.00
Display:
50…60 Hz: ±(2 % + 3 digit) (sine wave)
Accuracy:
voltage and current >1/10 of full scale
Monitor output (analog)
BNC connector (galvanic isolation
Connection:
to test circuit and RS-232 interface)
protective earth
Reference potential:
1 Vac at full scale (2400/8000 digit)
Level:
typ. 5 %
Accuracy:
approx. 10 kΩ
Output impedance:
DC…1 kHz
Bandwidth:
±30 V
Protected up to:
Functions and displays
Measurement functions:
Range selection:
Overrange alarm:
Display resolution
Voltage:
Current:
Power:
Power factor:
Interface
Interface:
voltage, current, power, power factor
automatic/manual
visual and acoustic
Conditions
1 V
Test signal voltage:
Open and short corrections performed
SLOW
Measurement time:
Display
Measurement modes:
Equivalent circuits:
Parameters displayed:
Averaging:
Accuracy
Primary Parameters:
Miscellaneous
Safety Class:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
Safety Class I (EN 61010)
115/230 V ±10 %, 50…60 Hz, CAT II
approx. 15 W at 50 Hz
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 4 kg
uto, L-Q, L-R, C-D, C-R, R-Q, Z-Θ, Y-Θ,
A
R-X, G-B, N-Θ, M
Auto, Series or Parallel
Value, Deviation or % Deviation
2…99 measurements
Basic accuracy
(Test voltage: 1.0 V,
measurement SLOW/MEDIUM,
autoranging mode, constant voltage OFF,
bias off). For FAST mode double the basic
accuracy values
Impedance: 100MΩ
4MΩ
0.2% + |Z|/1.5GΩ
1MΩ
25kΩ
Protocol:
Data rate:
Functions:
0.5% +
|Z|/100MΩ
0.05% +
|Z|/2GΩ
0.1% +
|Z|/1,5GΩ
0.2% +
|Z|/100MΩ
100Ω
0.1% + 1mΩ/|Z|
0.2% +
2mΩ/|Z|
0.3% + 1mΩ/|Z|
0.5% +
2mΩ/|Z|
0.5% +
5mΩ/|Z|
+
|Z|/10MΩ
2.5Ω
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD, Software
Recommended accessories:
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ10S 5 x silicone test lead black
HZ10R 5 x silicone test lead red
HZ10B 5 x silicone test lead blue
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ33
Test cable 50 Ω, BNC/BNC, 0.5 m
HZ34
Test cable 50 Ω, BNC/BNC, 1 m
HZ42
19” Rackmount kit 2RU
HZ72
GPIB-Cable 2 m
HZ815 Socket adapter
78
Product description, page 31
3-digit, 7-segment LED
4-digit, 7-segment LED
4-digit, 7-segment LED
3-digit, 7-segment LED
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
D-sub connector (galvanic isolation to test
circuit and monitor output)
Xon/Xoff
9600 Baud
control / data fetch
Connection RS-232:
200 kHz LCR-Bridge HM8118
0.01mΩ
20Hz
1kHz
10kHz
Secondary Parameters:
Basic accuracy D, Q:
±0.0001 @ f = 1 kHz
Phase angle:
±0.005° @ f = 1 kHz
Ranges
|Z|, R, X:
|Y|, G, B:
C:
L:
D:
Q:
θ:
∆:
M:
N:
0.01 mΩ…100 MΩ
10 nS…1000 S
0.01 pF…100 mF
10 nH…100 kH
0.0001…9.9999
0.1…9999.9
-180…+180°
-999.99…999.99 %
1 µH…100 H
0.95…500
Measurement conditions and functions
20 Hz…200 kHz (69 steps)
Test frequency:
±100 ppm
Frequency accuracy:
50 mVrms…1.5 Vrms
AC test signal level:
10 mVrms
Resolution:
±(5 % + 5 mV)
Drive level accuracy:
0…+5.00 Vdc
Internal Bias Voltage:
10 mV
Resolution:
0…+40 Vdc (fused 0.5 A)
External Bias Voltage:
0…+200 mA
Internal Bias Current:
1 mA
Resolution:
Auto and Hold
Range Selection:
100 kHz
Specifications
Trigger:
Continuous, manual or external via
interface, Binning Interface or Trigger
Input
0…999 ms in 1 ms steps
Trigger delay time:
Measurement time (f ≥1 kHz)
70 ms
FAST
125 ms
MEDIUM
0.7 s
SLOW
Other Instrument Functions
Voltage, current
Test signal level monitor:
Open, Short, Load
Error Correction:
9 instrument settings
Save/Recall:
Vmax <ZX
Front-end Protection:
2/C @ Vmax <200 V, C in Farads
(1 Joule of stored energy)
Low Potential and
Ground, Driven Guard or Auto (fused)
Low Current Guarding:
Constant Voltage Mode (25 Ω source)
Temperature effects:
±5 ppm/°C
R, L or C:
USB/RS-232 (HO820),
Interface:
IEEE-488 (GPIB) (optional)
Safety Class I (EN61010-1)
Safety Class:
110…230 V ±10 %, 50…60 Hz, CAT II
Power supply:
approx. 20 W
Power consumption:
+5…+40 °C
Operating temperature:
-20…+70 °C
Storage temperature:
5…80 % (non condensing)
Rel. humidity:
285 x 75 x 365 mm
Dimensions (W x H x D):
approx. 4 kg
Weight:
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, HZ184 4 Terminal Kelvin
Test Cable and HZ188 4 Terminal SMD Component Test Fixture, CD
Recommended accessories:
HO118 Binning Interface
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ13
Interface cable (USB) 1.8 m
Interface cable (serial) 1:1
HZ14
Test cable 50 Ω, BNC/BNC, 0.5 m
HZ33
HZ34
Test cable 50 Ω, BNC/BNC, 1 m
HZ42
19” Rackmount kit 2RU
GPIB-Cable 2 m
HZ72
HZ181 4 Terminal Test Fixture including Shorting Plate
HZ186 4 Terminal Transformer Test Cable
Auto trigger (AC coupling):
Trigger slope:
Filter:
Input characteristics (Input C)
SMA socket
Connection:
100 MHz…3 GHz
Frequency range:
up to 1 GHz: 30 mVrms (typ. 20 mVrms)
Input sensitivity:
1…3 GHz: 100 mVrms (typ. 80 mVrms)
50 Ω nominal
Input impedance:
5 V (DC + ACpeak)
Max. input voltage:
Input characteristics
Input impedance:
Max. input voltage:
Input sensitivity:
High level:
Low level:
Min. pulse duration:
Input frequency:
Min. eff. gate time:
Product description, page 32
Input characteristics (Input A and B)
BNC socket
Connection:
Frequency range:
0…200 MHz
(DC-coupled)
10 Hz…200 MHz
(1 MΩ, AC-coupled)
500 kHz…200 MHz
(50 Ω, AC-coupled)
1 MΩ II 30 pF or 50 Ω (switchable)
Input impedance:
1:1, 1:10, 1:100 (selectable)
Attenuation:
Sensitivity: (normal triggering)
0…80 MHz
25 mVrms (sine wave), 80 mVpp (pulse)
65mVrms (sine wave)
80…200 MHz
20 Hz…80 MHz
50 mVrms (sine wave, auto trigger)
Trigger (programmable via encoder or software)
Attenuation:
Trigger level:
Resolution:
1:1
0…±2 V
1 mV
1:10
0…±20 V
10 mV
1:100
0…±200 V
100 mV
Max. input voltage:
250 V (DC + ACpeak)
Input 1 MΩ:
from 0…440 Hz decreasing to 8 Vrms at 1 MHz
5 Vrms
Input 50 Ω:
<5 ns for single pulse
Minimum pulse duration:
(typ.) 100 µV
Input noise:
External Reset Reference Gate/Arming
500 Ω
5 kΩ
5 kΩ
±20 V
±30 V
±30 V
-
typ. 2 Vpp>2 V-
>2 V
<0.5 V
<0.5 V-
50 ns
200 ns-
-
10 MHz--
20 µs
Measurement functions
Frequency A/B/C; period duration A; width A; totalize A; RPM A; frequency
ratio A:B; time interval A:B; time interval A:B (average); phase A to B; Duty
cycle A; burst measurements
Frequency measurement (Inputs A, B, C)
0…200 MHz (3 GHz)
Frequency range:
(1.25 x 10-8s x frequency)/measurement
LSD:
time
1 LSD
Resolution:
±(resolution/frequency
Accuracy:
±time inaccuracy
±trigger error2)/measurement time)
Period duration measurement
5 ns…10,000 s
Range:
(1.25 x 10-8s x period)/measurement time
LSD:
1 LSD
Resolution:
±resolution/period
Accuracy:
±(trigger error2) /measurement time)
Totalization A
Range:
Min. pulse duration:
LSD:
Resolution:
Accuracy:
3 GHz Programmable Counter HM8123
trigger point: 50 % of peak-to-peak value
Rising or falling
100 kHz low-pass filter (selectable)
Pulse resolution:
Ext. gate error:
(external control)
(manual control)
0…200 MHz
0…200 MHz
10 ns
10 ns
1 count
±1 count
LSD
LSD
(resolution ±ext. gate time error
x frequency A)/total
10 ns
10 ns
-
100 ns
Time interval /Average time interval
(Input A = start; input B = stop)
10 ns (0,1 ps…10 ns in „average“ mode)
LSD:
1 LSD
Resolution:
±(resolution + trigger error 2)
Accuracy:
+system error)/time interval
±time base uncertainty
(system error: ≤4 ns)
N = 1…25
LSD = 10 ns
Number of average:
N = 26…2,500
LSD = 1 ns
N = 2,501…250,000
LSD = 100 ps
N = 250,001…25,000,000 LSD = 10 ps
N = >25,000,000
LSD = 0.1 ps
RPM measurement
NPR1) presetting:
Gate time:
LSD:
Resolution:
Accuracy:
Offset
Range:
1…65,535 pulses per revolution
330 ms fixed
7.5x 10-8 x revolution speed
1 LSD
±(trigger error 2)/0.33)
±time base error
Covers the entire measurement range
79
Specifications
Resolution:
Same resolution as in normal measure­
ment. If the gate time is changed in the
offset mode, the offset resolution is the
reference value resolution or the current
reading resolution (whichever is less
precise).
Gate time
Range:
Resolution:
External gate time:
1 ms…65 s
1 ms
min. 20 µs
Time base
Frequency:
Temperature stability
(0…50 °C):
Aging TCXO:
OCXO:
External Reference:
400 MHz clock rate; 10 MHz crystal
TCXO (standard): ±0,5x 10-6
OCXO (HO85): ±1x 10-8
<0.27 ppm per month, 0.05 ppm per day
≤±1x 10-9/day
10 MHz ±20 ppm
Miscellaneous
Interface:
Safety class:
Display:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
Safety Class I (EN61010-1)
LCD display (83 x 21 mm)
115…230 V ±10 %, 45…60 Hz, CAT II
approx. 20 W
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 4 kg
All data valid at 23 °C after 30 minutes warm-up.
1)
NPR=number of pulses per revolution
2)
Trigger error= ±noise input (Vpp)/slew rate of the input signal
Accessories supplied: Line cord, Operating manual, CD
Recommended accessories:
HO85 OCXO (Installation only ex factory)
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ13
Interface cable (USB) 1.8 m
Interface cable (serial) 1:1
HZ14
Adapter plug
HZ20
HZ24
Attenuators 50 Ω
HZ33
Test cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test cable 50 Ω (BNC-BNC) 1.0 m
19’’ Rackmount kit 2RU
HZ42
HZ72
GPIB-Cable 2 m
1.2 GHz RF-Synthesizer HM8134-3
Product description, page 33
Frequency
Range:
Resolution:
Settling time:
1 Hz…1200 MHz
1 Hz
<10 ms
Frequency Reference 10 MHz
Standard: TCXO
Temperature stability
≤±0.5 ppm
(0…50 °C):
≤±1 ppm/year
Aging:
Option: OCXO (HO85)
Temperature stability
≤±1x 10-8
(0…50 °C):
≤±1x 10-9/day
Aging:
(rear panel)
Internal reference output:
TTL
Level:
(rear panel)
External reference input:
>0 dBm
Level:
10 MHz ±20 ppm
Frequency:
80
Spectral purity (without modulation)
≤-35 dBc
Harmonics:
≤-55 dBc (>15 kHz from carrier)
Non-harmonics:
(at 20kHz from carrier)
Phase noise:
≤-120dBc/Hz
f <16 MHz:
≤-94 dBc/Hz
16 MHz ≤f <250 MHz:
≤-105 dBc/Hz
250 MHz ≤f <500 MHz:
500 MHz ≤f <1000 MHz: ≤-100 dBc/Hz
1000 MHz ≤f <1200 MHz: ≤-95 dBc/Hz
≤6.5 Hz (at 1 GHz in 0.3…3 kHz bandwidth)
Residual FM:
typ. <0.06 % (in 0.03…20 kHz bandwidth)
Residual AM:
(Typical phase noise at 1 GHz)
Output level
Range:
Resolution:
Display-Offset for ext. Attn.:
Precision:
for level >-57 dBm:
for level <-57 dBm:
Impedance:
V.S.W.R.:
Modulation sources
Internal:
Resolution:
External:
Impedance:
Input level:
Coupling:
Output:
Level:
Impedance:
-127…+13 dBm
0.1 dB
0.0…30.0 dB in 0.1 dB steps
≤±0.5 dB
≤±(0.5 dB + (0.2x (-57 dBm - level))/10)
50 Ω
≤2
10 Hz…150 kHz sine wave,
10 Hz…20 kHz square wave, triangle,
sawtooth
10 Hz
(input on front panel)
10 kΩ II 50 pF
2 Vpp for full scale
AC or DC
(on front panel)
2 Vpp
1 kΩ
Amplitude modulation (Level ≤ +7 dBm)
internal or external
Source:
0…100 %
Modulation depth:
0.1 %
Resolution:
±4 % of reading
Accuracy:
±0.5 % (AM-depth ≤80 %, fmod ≤40 kHz)
Ext. frequency resp.
10 Hz…50 kHz for AC
(to -1 dB):
<2 % (AM-depth ≤60 %, fmod ≤1 kHz)
Distortion:
<6 % (AM-depth ≤80 %, fmod <20 kHz)
Frequency modulation
Source:
Deviation:
internal or external
±200 Hz…400 kHz
(depending on frequency band)
100 Hz
Resolution:
±3 % + res. FM (fmod ≤5 kHz)
Accuracy:
±7 % + res. FM (5 kHz <fmod <100 kHz)
Ext. frequency response (to -1 dB):
0…100 kHz
DC coupling:
10 Hz…100 kHz
AC coupling:
<1 % for deviation ≥50 kHz at 1 kHz
Distortion:
<3 % for deviation ≥10 kHz at 1 kHz
Specifications
Phase modulation
internal or external
Source:
Deviation:
0…3.14 rad
<16 MHz:
0…10 rad
>16 MHz:
0.01 rad
Resolution:
±5 % up to 1 kHz + residual PM
Accuracy:
Ext. frequency response (to -1 dB):
0…100 kHz
DC coupling:
10 Hz…100 kHz
AC coupling:
<3 % for fmod = 1 kHz and deviation = 10 rad
Distortion:
FSK modulation
Range (F0…F1):
Mode:
Data source:
Max. rate:
Shift (F1…F0):
Resolution:
Accuracy:
PSK modulation
Mode:
Data source:
Max. rate:
Shift (Ph1…Ph0):
<16 MHz:
>16 MHz:
Resolution:
Accuracy:
16…1200 MHz
2 FSK levels
external
10 kbit/s
0…10 MHz
100 Hz
±3 % + residual FM (fmod ≤5 kHz)
±7 % + residual FM (5 kHz <fmod <100 kHz)
2 PSK levels
external
10 kbit/s
0…±3.14 rad
0…±10 rad
0.01 rad
±5 % up to 1 kHz + residual PM
Pulse modulation
Source:
Dynamic range:
Rise/fall times:
Delay:
Max. frequency:
Input level:
external (rear panel)
>80 dB
<50 ns
<100 ns
2.5 MHz
TTL
Sweep mode
Range:
Depth:
Sweep time:
Trigger:
1…1200 MHz
500 Hz…1199 MHz
20 ms…5 s
internal
3 GHz RF-Synthesizer HM8135
Product description, page 34
Frequency
Range:
Resolution:
Settling time:
1 Hz…3 GHz
1 Hz
<10 ms
Frequency Reference 10 MHz
Standard: TCXO
Temperature stability
≤±0.5 ppm
(0…50 °C):
≤±1 ppm/year
Aging:
Option: OCXO (HO85)
Temperature stability
≤±1x 10-8
(0…50 °C):
≤±1x 10-9/day
Aging:
(rear panel)
Internal reference output:
TTL
Level:
(rear panel)
External reference input:
>0 dBm
Level:
10 MHz ±20 ppm
Frequency:
Spectral purity (without modulation)
≤-35 dBc
Harmonics:
≤-50 dBc (>15 kHz from carrier)
Non-harmonics:
≤-50 dBc
Sub-harmonics:
(at 20 kHz from carrier)
Phase noise:
≤-120 dBc/Hz
f <16 MHz:
≤-95 dBc/Hz
16 MHz ≤f <250 MHz:
≤-105 dBc/Hz
250 MHz ≤f <500 MHz:
500 MHz ≤f <1000 MHz: ≤-100 dBc/Hz
≤-95 dBc/Hz
1 GHz ≤f <2 GHz:
≤-90 dBc/Hz
2 GHz ≤f <3 GHz:
typ. <4 Hz; ≤6.5 Hz (in 0.3…3 kHz bandwidth)
Residual FM:
typ. <0.06 % (in 0.03…20 kHz bandwidth)
Residual AM:
Protective functions
The synthesizer is protected against reverse power applied to the RF
output up to 1 W for a 50 Ω source and against any DC source up to ±7 V.
The protection disconnects the output until manually reset by operator.
Miscellaneous
Interface:
Configuration memories:
Safety class:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
10
Safety Class I (EN61010-1)
115/230 V ±10 %, 50…60 Hz, CAT II
approx. 40 VA
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD
Recommended accessories:
HO85 OCXO temperature stability ±1x 10-8
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ20
Adapter, BNC to 4 mm banana
HZ21
Adapter plug
HZ24
Attenuator Set 50 Ω (3/6/10/20 dB)
HZ33
Test Cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test Cable 50 Ω (BNC-BNC) 1.0 m
HZ42
19’’ Rackmount kit 2RU
HZ72
GPIB-Cable 2 m
(Typical phase noise at 1 GHz)
Output level
-135…+13 dBm
Range:
0.1 dB
Resolution:
Display-Offset for ext. Attn.: 0.0…30.0 dB in 0.1 dB steps
Precision f <1.5 GHz; level >-120 dBm
for level >-57 dBm:
≤±0.5 dB
for level <-57 dBm:
≤±(0.5 dB + (0.2 x (-57 dBm - level))/10)
Precision f >1.5 GHz; level >-120 dBm
for level >-57 dBm:
≤±0.7 dB
for level <-57 dBm:
≤±(0.7 dB + (0.5x (-57 dBm - level))/10)
50 Ω
Impedance:
≤1.5
f ≤1 GHz:
V.S.W.R.:
≤2.5
f >1 GHz:
Modulation sources
Internal:
Resolution:
External:
10 Hz…200 kHz sine wave
10 Hz…20 kHz square wave, triangle,
sawtooth
10 Hz
Input on front panel
81
Specifications
Impedance:
Input level:
Coupling:
Output:
Level
Impedance:
10 kΩ II 50 pF
2 Vpp for full scale
AC or DC
Front panel
2 Vpp
1 kΩ
Amplitude modulation (Level ≤+7 dBm)
Internal or external
Source:
0…100 %
AM-depth:
0.1 %
Resolution:
±4 % displayed rate
Accuracy:
±0.5 %(AM-depth ≤80 %, fmod ≤50 kHz)
Ext. frequency resp.
10 Hz…100 kHz for AC
(to -1 dB):
<2 % (AM-depth ≤60 %, fmod ≤1 kHz)
Distortion:
<6 % (AM-depth ≤80 %, fmod <20 kHz)
Frequency modulation
Source:
Deviation:
Resolution:
Accuracy:
Ext. frequency response
(to -1 dB):
DC coupling:
AC coupling:
Distortion:
Phase modulation
Source:
Deviation:
<16 MHz:
>16 MHz:
Resolution:
Accuracy:
Ext. frequency response
(to -1dB):
DC coupling:
AC coupling:
Distortion:
FSK modulation
Range (F0…F1):
Mode:
Data source:
Max. rate:
Shift (F1…F0):
Resolution:
Accuracy:
PSK modulation
Mode:
Data source:
Max. rate:
Shift (Ph1…Ph0):
<16 MHz:
>16 MHz:
Resolution:
Accuracy:
Pulse modulation
Source:
Dynamic range:
f <2 GHz:
f >2 GHz:
Rise/fall times:
Delay:
Max. frequency:
Input level:
Sweep mode
Range:
Depth:
Sweep time:
82
internal or external
±200 Hz…400 kHz
(depending on frequency band)
100 Hz
±3 % + residual FM (fmod ≤5 kHz)
±7 % + residual FM (5 kHz <fmod <100 kHz)
0…100 kHz
100 Hz…100 kHz
<1 % for deviation ≥50 kHz at 1 kHz
<3 % for deviation ≥10 kHz
internal or external
Trigger:
internal
Protective functions
The synthesizer is protected against reverse power applied to the RF output
up to 1 W for a 50 Ω source and against any DC source up to ±7 V. The pro­
tection disconnects the output until manually reset by operator.
Miscellaneous
Interfaces:
Configuration memories:
Safety class:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
10
Safety Class I (EN61010-1)
115/230 V ±10 %, 50…60 Hz, CAT II
approx. 40 VA
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD
Recommended accessories:
HO85 OCXO temperature stability ±1 x 10-8
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
Interface cable (USB) 1.8 m
HZ13
HZ14
Interface cable (serial) 1:1
HZ20
Adapter, BNC to 4 mm banana
Adapter plug
HZ21
HZ24
Attenuator Set 50 Ω (3/6/10/20 dB)
HZ33
Test Cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test Cable 50 Ω (BNC-BNC) 1.0 m
19’’ Rackmount kit 2RU
HZ42
HZ72
GPIB-Cable 2 m
0…3.14 rad
0…10 rad
0.01 rad
±5 % up to 1 kHz + residual PM
0…100 kHz
100 Hz…100 kHz
<3 % for fmod = 1 kHz and deviation = 10 rad
16 MHz…3 GHz
2 FSK levels
external
10 kbit/s
0…10 MHz
100 Hz
±3 % + residual FM (fmod ≤5 kHz)
±7 % + residual FM (5 kHz <fmod <100 kHz)
2 PSK levels
external
10 kbit/s
0…±3.14 rad
0…±10 rad
0.01 rad
±5 % up to 1 kHz + residual PM
external (rear panel)
>80 dB
>55 dB
<50 ns (typ. <10 ns)
<100 ns
2.5 MHz (typ. 5 MHz)
TTL
1…3000 MHz
500 Hz…2999 MHz
20 ms…5 s
12.5 MHz Arbitrary Function Generator HM8150
Product description, page 35
Frequency
Range:
Resolution:
Accuracy:
Temperature coefficient:
Aging:
10 mHz…12.5 MHz
5 digit, max. 10 mHz
±(1 digit + 5 mHz)
0.5 ppm/°C
2 ppm/year
Waveforms
Sine wave
10 mHz…12.5 MHz
Frequency range:
20 mVpp…20 Vpp (open circuit)
Amplitude:
Harmonic Distortion @ 1 Vpp:
f <500 kHz:
-65 dBc
500 kHz ≤f <5 MHz:
-50 dBc
-40 dBc
5 MHz ≤f ≤12.5 MHz:
Total Harmonic Distortion @ 1 Vpp:
f <100 kHz:
typ. 0.05%
Spurious (Non-Harmonic) @ 1 Vpp:
f <500 kHz:
-65 dBc
500 kHz ≤f ≤12.5 MHz:
-65 dBc + 6 dBc/octave
Square wave
Frequency range:
Amplitude:
Rise/fall time:
Overshoot:
Symmetry:
10 mHz…12.5 MHz
20 mVpp…20 Vpp (open circuit)
<10 ns
<5 % (Vout ≤200 mV)
50 % ±(5 % +10 ns)
Pulse
Frequency range:
Amplitude:
Rise/fall time:
Pulse width:
Duty cycle:
10 mHz…5 MHz
10 mVpp…+10 Vpp or -10 mVpp…-10 Vpp
<10 ns
100 ns…80 s
max. 90 %
Specifications
Sawtooth
Frequency range:
Amplitude:
Linearity:
10 mHz…25 kHz
20 mVpp…20 Vpp (open circuit)
better than 1 %
Triangle
Frequency range:
Amplitude:
Linearity:
10 mHz…250 kHz
20 mVpp…20 Vpp (open circuit)
better than 1 %
Arbitrary generator
Frequency range:
Amplitude:
Output rate:
Resolution:
Inputs
Gate/Trigger:
Impedance:
Max. input voltage:
Modulation Input:
Impedance:
Max. input voltage:
10 mHz…250 kHz
20 mVpp…20 Vpp (open circuit)
40 MSa/s
X: 1024 (10 bit), Y: 1024 (10 bit) or
X: 4096 (12 bit), Y: 4096 (12 bit)
BNC connector
5 kΩ II 100 pF
±30 V
BNC connector
10 kΩ
±30 V
Display:
Memory:
Safety Class:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
16 characters, LCD with backlight
for the last device settings and for
1 arbitrary signal
Safety Class I (EN61010-1)
115…230 V ±10 %; 50…60 Hz, CAT II
approx. 20 W
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 5 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD, Software
Recommended accessories:
HO880 IEEE-488 (GPIB) Interface (galvanically isolated)
HZ13
Interface cable (USB) 1.8 m
Interface cable (serial) 1:1
HZ14
Adapter, BNC to 4 mm banana
HZ20
HZ24
Attenuator Set 50 Ω (3/6/10/20 dB)
HZ33
Test Cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test Cable 50 Ω (BNC-BNC) 1.0 m
HZ42
19’’ Rackmount kit 2RU
HZ72
GPIB-Cable 2 m
Outputs
Signal output:
BNC connector, short circuit proof,
ext. voltage up to ±15 V
50 Ω
Impedance:
2.1…20 Vpp (open circuit)
Range 1:
Output voltage:
Range 2:
0.21…2.0 Vpp (open circuit)
Range 3:
20…200 mVpp (open circuit)
100 mV
Range 1:
Resolution:
10 mV
Range 2:
1 mV
Range 3:
±2 %
Setting accuracy (1 kHz): Range 1:
Range 2:
±3 %
Range 3:
±4 %
3 % additional for pulse and square wave
<100 kHz
±0.2 dB
Frequency response:
0.1…12.5 MHz: ±0.5 dB
±50 mV
Range 3:
Offset error:
2½ digits (LCD)
Display:
BNC connector
Trigger output:
Level:
5 V/TTL
Impedance:
50 Ω
BNC connector
Sawtooth output:
Output voltage:
0…5 V, synchronous to sweep
Impedance:
1 kΩ
DC offset
Output voltage:
Range 1:-7.5…+7.5 V (open circuit)
Range 2:-0.75…+0.75 V (open circuit)
Range 3:-75…+75 mV (open circuit)
Vac range + 2 x Voffset range ≤Vrange max.
Sweep (internal)
Setting of start and stop frequencies
all waveforms
Internal sweep:
linear, 20 ms…100 s continuous or triggered
Sweep time:
(ext. signal, interface)
Amplitude Modulation
Modulation via external signal
0…100 %
Modulations depth:
DC…20 kHz (-3 dB)
Bandwidth:
Gate (asynchronuous)
Modulation on/off via external TTL signal
<150 ns
Delay time:
TTL
Input singal:
Trigger Function (synchronuous)
Burst mode via ext. trigger input or interface
<500 kHz
Frequency range:
Miscellaneous
Interface:
USB/RS-232 (HO820),
IEEE-488 (GPIB) (optional)
25 MHz Arbitrary Function Generator HMF2525
50 MHz Arbitrary Function Generator HMF2550
Product description, page 28
Frequency
HMF2525:
HMF2550:
Temperature stability:
Aging (after 1 year):
Amplitude
Output voltage:
Resolution:
Setting accuracy:
Frequency response (Sine):
10 µHz…25 MHz
10 µHz…50 MHz
1 ppm (18…28 °C)
±1 ppm (25 °C)
5 mVpp…10 Vpp (into 50 Ω)
10 mVpp…20 Vpp (open circuit)
1 mV (into 50 Ω)
±(1 % of control + 1 mVpp) at 1 kHz
f <10 MHz: <±0.15 dB
10 MHz ≤f <25 MHz: <±0.2 dB
25 MHz ≤f <50 MHz: <±0.4 dB
DC offset:
Voltage range (AC + DC) ±5 mV…5 V (into 50 Ω)
±10 mV…10 V (open circuit)
±2 % of offset
Accuracy
±0.5 % of signal level
±2 mV
±1 mV/MHz
Vpp, dBm
Units:
Waveform Sine Wave
Total harmonic distortion (1 Vpp):
f <100 kHz:
<-70 dBc
100 kHz ≤f <10 MHz
<-55 dBc
10 MHz ≤f <25 MHz
<-40 dBc
f ≥25 MHz
<-37 dBc
Spurious (Non-harmonics 1 Vpp):
f <1MHz:-70dBc
1 MHz <f <50 MHz
-70dBc + 6dB/Octave
Total harmonic distortion
0.04 % typ.
(f ≤100 kHz):
Phase noise:
(10 MHz, 10 kHz Offset,
<-115 dBc/Hz typ.
1 Vpp)
Waveform Square
Rise/fall time:
Overshoot:
Symmetry (50% duty cycle):
Jitter (RMS):
<8 ns
<3 % typ.
1 % + 5 ns
<1 ns typ.
83
Specifications
Waveform Pulse
Frequency range:
HMF2525
HMF2550
Amplitude:
Rise/fall time:
Pulse width:
Resolution:
Jitter (RMS):
Overshoot:
100 µHz…12.5 MHz
100 µHz…25 MHz
5 mV…+5 V respectively
-5 mV…-5 V (into 50 Ω)
<8 ns, variable up to 500 ns
15 ns…999 s
5 ns
<500 ps typ.
<3 % typ.
Waveform Ramp, Triangle
Frequency range:
10 µHz…5 MHz
HMF2525
10 µHz…10 MHz
HMF2550
1…99 %
Symmetry:
Linearity:
f <250 kHz
<0.1 % typ.
f ≥250 kHz
<2 % typ.
Waveform Arbitrary
Frequency range:
HMF2525
HMF2550
Sample rate:
Amplitude resolution:
Bandwidth (-3 dB):
Signal length:
Non-volatile memory:
Predefined waveforms:
Inputs and Outputs
Signal output:
10 µHz…12.5 MHz
10 µHz…25 MHz
250 MSa/s
14 Bit
>50 MHz
Up to 256 kPts
up to 4 MB (internal file system)
Sine, square (50 %),
ramp (positive/negative), triangle (50 %),
noise (white/pink), cardinal sine,
exponential (rise/fall)
Impedance
Gate/Trigger input:
Impedance
Level
Edge
Pulse width
Trigger output:
Impedance
Level
Frequency
Modulation input:
Impedance
Max. input voltage
Bandwidth (-3 dB)
Reference input:
Impedance
Frequency
Input voltage
Reference output:
Impedance
Frequency
Output voltage
Ramp output:
Impedance
Output voltage
BNC socket (frontside), short-circuit-proof,
ext. voltage ±15 V max.
50 Ω
BNC socket (frontside)
5 kΩ || 100 pF
TTL (protected up to ±30 V)
Positive/negative (selectable)
Min. 100 ns
BNC socket (frontside)
50 Ω
Positive TTL level impulse
10 MHz max.
BNC socket (rear side)
10 kΩ
±5 V for full scale
DC…50 kHz (sample with 250 kSa/s)
BNC socket (rear side)
1 kΩ
10 MHz ±100 kHz
TTL
BNC socket (rear side)
50 Ω
10 MHz
1.65 Vpp (into 50 Ω)
BNC socket (rear side)
200 Ω
0…5 V, synchronous with sweep
Sweep
Signals:
Type:
Direction:
Sweep time:
All (except pulse)
linear/logarithmic
up/down
1 ms…500 s
Burst
Signals:
Type:
Start/stop phase:
Trigger source:
Internal Trigger period:
84
All
Internal/external triggered, 1…50,000 cycles,
Immediate or Gate controlled
0…360° (sine only)
Manual, internal or external via Trigger
source or interface
1 µs…500 s
Modulation
Type of modulation:
Waveform carrier:
Internal modulation
(waveform):
Internal modulation
frequency:
Ext. modulation bandwidth
(-3 dB):
Amplitude modulation:
Modulation depth
Frequency modulation:
Frequency deviation
Phase modulation:
Phase deviation
Pulse width modulation:
Deviation
Miscellaneous
Display:
Interface:
Save/Recall memory:
Protection class:
Power supply:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
AM, FM, PM, PWM, FSK
All (except pulse)
Sine, square (50 %),
ramp (positive/negative), triangle (50 %),
noise (white/pink), cardinal sine,
exponential (rise/fall),
Arbitrary with up to 4096 Pts.
10 µHz…50 kHz
DC…50 kHz (sampled at 250 kSa/s)
0…100 %
Max. 10 MHz
-180…+180 °
0…49,99 % of the pulse width
8.9 cm (3.5”) color TFT QVGA 65 k colors
Dual-Interface USB/RS-232 (HO720)
4 MB internal file system/ext. USB
Safety class I (EN61010-1)
105…253 V, 50…60 Hz, CAT II
approx. 30 W
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
3.4 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual, CD, Software
Recommended accessories:
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB), galvanically isolated
HZ13
Interface cable (USB) 1.8 m
HZ14
Interface cable (serial) 1:1
HZ20
Adapter plug BNC plug - 4 mm safety sockets
HZ24
Attenuators 3/6/10 and 20 dB
HZ33
Test cable BNC plug - BNC plug 0.5 m
Test cable BNC plug - BNC plug 1.0 m
HZ34
HZ42
19’’ Rackmount kit 2RU
HZ72
IEEE-488 (GPIB) Cable 2m
Mainframe HM8001-2
Product description, page 38
General information
Mainframe with power supply accommodates 2 modules
Power supply module
Details of available supply
voltages and load capability: refer to manual HM8001 (www.hameg.com)
2 x 8 Vac max. 0.4 A each
2 x 5 Vdc max. 1 A each
4 x 20 Vdc max. 0.5 A each
Voltages between 5 V and 20 V are programmable from each module
(Polarity selectable)
each module max. 25 W
Available output power:
All DC voltages are electronically stabilized,
floating and short-circuit proof. Current
output of 2 HM8040-3 with HM8001-2:
sum of all channels <2 A
Miscellaneous
Power switch (ON/OFF) located between the two modules on the front
panel.
Safety Class I (EN61010-1)
Safety class:
Specifications
Power supply:
Max. permissible
line fluctuation:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
115/230 V~ (50…60 Hz), CAT II
±10 %
max. 110 W (with overload protection)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
285 x 75 x 365 mm
approx. 4 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Line cord, Operating manual
Recommended accessories:
HO801 4 BNC connectors
HZ42
19’’ Rackmount kit 2RU
HZ809 Test Adapter
4¾-Digit Programmable Multimeter HM8012
Resolution:
CMRR:
Crest factor:
AC current
Measurement ranges:
Resolution:
Accuracy:
0.5…500 mA:
10 A:
dB Mode
Accuracy:
Resolution:
DC current
Measurement ranges:
Resolution:
Accuracy:
0.5…500 mA:
10 A:
Voltage drop:
10 A range:
500 mA range:
other ranges:
AC voltage
Measurement ranges:
Resolution:
Accuracy 0.5…50 V:
40 Hz…5 kHz:
20 Hz…20 kHz:
Accuracy 500 V and 600 V:
40 Hz…1 kHz:
20 Hz…1 kHz:
Overload protection:
V/Ω/T°/dB/
to
COM and to chassis:
COM against chassis:
Input impedance
AC mode:
AC + DC mode:
Bandwidth at -3 dB:
dB mode:
Accuracy
-23.8…59.8 dBm:
±(0.02 dB + 2 digits) (display >-38.7 dBm)
0.01 dB above 18 % of rating
500 µA, 5 mA, 50 mA, 500 mA, 10 A
10 nA, 100 nA, 1 µA, 10 µA, 1 mA
±(0.2 % of reading + 0.004 % of full scale)
±(0.3 % of reading + 0.004 % of full scale)
0.2 V max.
2.5 V max.
0.7 V max.
500 mV, 5 V, 50 V, 500 V, 600 V
10 µV, 100 µV, 1 mV, 10 mV, 100 mV
±(0.4 % of reading + 0.07 % of full scale)
±(1 % of reading + 0.07 % of full scale)
±(0.4 % of reading + 0.07 % of full scale)
±(1 % of reading + 0.07 % of full scale)
850 Vp at max. 60 Hz or 600 Vdc
250 Vrms at max. 60 Hz or 250 Vdc
500 µA, 5 mA, 50 mA, 500 mA, 10 A
10 nA, 100 nA, 1 µA, 10 µA, 1 mA
±(0.7 % of reading + 0.07 % of f.s.)
40 Hz…5 kHz
±(1 % of reading + 0.07 % of full scale)
AC + DC measurements
As shown for AC + 25 digits
Resistance
Measurement ranges:
Resolution:
Accuracy:
500 Ω…500 kΩ:
5…50MΩ:
Overload Protection:
Measurement current:
Product description, page 39
DC voltage
500 mV, 5 V, 50 V, 500 V, 600 V
Measurement ranges:
10 µV, 100 µV, 1 mV, 10 mV, 100 mV
Resolution:
Accuracy:
5 V, 500 V, 600 V:
±(0.05 % of reading +0.002 % of full scale)
500 mV, 50 V:
±(0.05 % of reading +0.004 % of full scale)
Overload protection:
V/Ω/T°/dB/
to
850 Vp at max. 60 Hz or 600 Vdc
COM and to chassis:
COM against chassis:
250 Vrms at max. 60 Hz or 250 Vdc
Input resistance:
50 V, 500 V, 600 V:
10 MΩ II 90 pF
500 mV, 5 V:
>1 GΩ II 90 pF
10 pA
Input current:
Common mode rejection ratio: ≥100 dB (50…60 Hz ±0.5 %)
Serial mode rejection ratio: ≥60 dB (50…60 Hz ±0.5 %)
0.01 dB above 9 mV
≥60 dB (50…60 Hz ±0.5 %)
7 max.
Measurement voltage:
Temperature
2-wire resistance
­measurement
Range:
Resolution:
Measurement current:
Display:
Accuracy:
500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 50 MΩ
10 mΩ, 100 mΩ, 1 Ω, 10 Ω, 100 Ω, 1 kΩ
±(0.05 % of reading + 0.004 % of f.s.+50 mΩ)
±(0.3 % of reading + 0.004 % of full scale)
max. 300 Vrms
1mA
500 Ω…5kΩ range:
100µA
50 kΩ range:
10 µA
500 kΩ range:
100 nA
5…50 MΩ range:
10 V typical for open inputs, depending
on the value of resistance to be measured.
Negative polarity of measurement voltage
is across common terminal.
with linearization for PT100 sensors as per
standard EN60751
-200…+500 °C
0.1 °C
approx. 1 mA
in °C, °F
±(0.4 °C + 0.0005 x T) from -200…+200 °C
±(0.5 °C + 0.0005 x T) from +200…+500 °C
(T in °C, sensor tolerance not included)
Temperature coefficient: (reference 23 °C)
V = 500 mV, 50 V
30 ppm/°C
600 V range
80 ppm/°C
other ranges
20 ppm/°C
80 ppm/°C
V ~ 600 V range
other ranges
50 ppm/°C
mA all ranges
200 ppm/°C
mA~all ranges
300 ppm/°C
200 ppm/°C
Ω 5 MΩ, 50 MΩ ranges
other ranges
50 ppm/°C
Miscellaneous
Power supply (from mainframe):
+5 V
300 mA
~26 V
140 mA
+5…+40 °C
Operating temperature:
-20…+70 °C
Storage temperature:
5…80 % (non condensing)
Rel. humidity:
Dimensions (W x H x D)
(without 22-pole flat plug): 135 x 68 x 228 mm
approx. 0.5 kg
Weight:
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Operating manual, Interface cable (HZ14),
PVC test leads (HZ15), CD, Software
Recommended accessories:
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
HZ812 PT100 Temperature probe
1 MΩ II 90 pF
10 MΩ II 90 pF
80 kHz typical
20 Hz…20 kHz
±0.2 dBm
85
Specifications
25 kHz-LCR-Meter HM8018
Product description, page 39
Measurement functions
Measuring modes:
Equivalent circuits:
Measuring method:
Measuring ranges:
Basic accuracy:
Measuring frequencies:
Freq. Accuracy:
Measuring voltage:
Measuring rate:
Range changing:
DC Bias voltage:
Zero setting:
Compensation limits:
R, L, C, Θ, Q/D, |Z|
serial, parallel
2-wire, 4-wire
R: 0.001 Ω…99.9 MΩ
C: 0.001 pF…99.9 mF
L: 0.01 µH…9999 H
Q: 0.0001…99.9
D: 0.0001…9.9999
Θ: (-180.00°)…(+180.00°)
0.2 %
100 Hz, 120 Hz, 1 kHz, 10 kHz, 25 kHz
±100 ppm
(except 120 Hz: 120.2 Hz ±100 ppm)
0.5 Vrms ±10 % (unloaded)
2 measurements/second
automatic, manual
1 V ±10 %
Open/short circuit compensation
Short:R <10 Ω
Z <15 Ω
Open: Z >10 kΩ
Measurement accuracy
with D <0.1 or Q >10:
C: Ae = Af (1 + Cx /Cmax + Cmin /Cx)
L: Ae = Af (1 + Lx /Lmax + Lmin /Lx)
Z: Ae = Af (1 + Zx /Zmax + Zmin /Zx)
R: Ae = Af (1 + Rx /Rmax + Rmin /Rx)
with D ≥0.1:
Ae = ZX
1 + Dx2
with the parameters:
Cx = Measurement value
Af = 0.2 % at f = 100 Hz, 120 Hz, 1 kHz
Af = 0.3 % at f = 10 kHz
Af = 0.5 % at f = 25 kHz­
Parameter
Cmax
Cmin
Lmax
Zmax, Rmax
Zmin, Rmin
Auto Range
160 µF/f (f in kHz)
53 pF/f (f in kHz)
480 H/f (f in kHz)
3 MΩ
0.5 Ω
Dissipation factor accuracy:
Quality factor accuracy:
Phase angle accuracy:
Display
5-digits 7-Segment LEDs with sign
Display Parameters:
Value
Calculation from measurement value and
% Value
reference value stored
Deviation
% Offset
}
Miscellaneous
The inputs are short-circuit-proof and overvoltage protected up to 100 Vdc
with a maximum energy consumption of 1 J.
One configuration can be saved.
+5 V/300 mA
Power supply
+5.2 V/50 mA
(from mainframe):
-5.2 V/50 mA
(∑ = 2 W)
+5…+40 °C
Operating temperature:
-20…+70 °C
Storage temperature:
5…80 % (non condensing)
Rel. humidity:
Dimensions (W x H x D)
(without 22-pole flat plug): 135 x 68 x 228 mm
approx. 0.5 kg
Weight:
All data valid at 23 °C after 30 minutes warm-up.
86
Included in delivery: Operating manual, CD
Recommended accessories:
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
HZ17
Kelvin test lead (4 wire) with probe tips
HZ18
Kelvin test lead (4 wire) with gold plated contacts
HZ19
Kelvin test lead (4 wire) with SMD-Test-tweezers
1.6 GHz Universal Counter HM8021-4
Product description, page 40
Measurement functions
Frequency A /C, Period A;
Totalize A;
/
(averaged);
Pulse width:
Totalling A during ext. gate
Input characteristics (Input A)
Frequency range:
DC-coupled
0…150 MHz:
10 Hz…150 MHz:
AC-coupled
Sensitivity: (normal triggering)
DC…80 MHz
20 mVrms (sine wave)
80 mV (pulse)
80…150 MHz
60 mVrms (sine wave)
20 Hz…80 MHz (auto trig.) 50 mVrms (sine wave)
5 ns
Minimum pulse width:
100 µV (typ.)
Input noise:
AC or DC (selectable)
Coupling:
1 MΩ II 40 pF
Input impedance:
x1, x20 (selectable)
Attenuator:
Max. input voltage:
400 V (DC + ACpeak)
0…440 Hz:
1 MHz:
decreasing to 8 Vrms
Input characteristics (Input C)
100 MHz…1.6 GHz
Frequency range:
Sensitivity:
30 mV (typ. 20 mV)
to 1.3 GHz:
to 1.6 GHz:
100 mV (typ. 80 mV)
50 Ω nominal
Input impedance:
AC
Coupling:
5 V (DC + ACpeak)
Max. input voltage:
Input characteristics (external gate)
4.7 kΩ
Input impedance:
±30 V
Max. input voltage:
>2 V/<0.5 V
High/low level:
50 ns
Min. pulse duration:
150 µs
Min. effective gate time:
Frequency measurement (Input A)
(2.5 x 10-7s x freq.)/measurement time
LSD:
1 LSD
Resolution:
Period duration measurement
66.6 ns…10,000 s
Range:
(2.5 x 10-7s x period)/measurement time
LSD:
1 LSD
Resolution:
Totalling (manually/externally gated)
DC…20 MHz
Range:
25 ns
Min. pulse duration:
1 count
LSD:
LSD
Resolution:
Ext. gate error:
100 ns
in manual mode only
Time interval (averaged)
10 ps…100 ns
LSD:
1 LSD
Resolution:
Specifications
Offset
Range:
covers the entire measurement range
Gate time
(Gate time cannot be less than 1 period.)
100 ms…10 s in 3 steps
Range:
min. 150 µs
External gate time:
Timebase
Frequency:
Accuracy
(between 10 °C and 40 °C):
Aging:
Miscellaneous
Display:
Power consumption:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
10 MHz clock
10 MHz crystal
DC offset:
into 50 Ω load:
in open circuit:
Trigger output:
FM input
(VCF, BNC connector on rear panel of HM8001-2 and option HO801)
approx. 1:100
Frequency deviation:
6 kΩ II 25 pF
Input impedance:
max. ±30 V
Input voltage:
±5x 10-7
±3 ppm/15 years
Internal sweep
Sweep speed:
Sweep range:
8-digit 7-segment LED display with
7.65 mm digit height, sign and exponent
approx. 7 W
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
135 x 68 x 228 mm
approx. 0.6 kg
Miscellaneous
Power supply
(from mainframe):
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Operating manual, CD
Recommended accessories:
HZ20
Adapter, BNC to 4mm banana
Attenuators 50 Ω (3/6/10/20 dB)
HZ24
HZ33
Test Cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test Cable 50 Ω (BNC-BNC) 1.0 m
variable (on/off, except pulse function)
max. ±2.5 V
max. ±5 V
square wave synchronous to approx.
+5 V/TTL
20 ms…15 s
approx. 1:100
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D)
(without 22-pole flat plug):
Weight:
+5 V/200 mA
+16 V/300 mA
-16 V/250 mA
(∑ = 9.8 W)
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
135 x 68 x 228 mm
approx. 0.8 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Operating manual, CD
Recommended accessories:
Adapter, BNC to 4 mm banana
HZ20
HZ22
Feed-Through Termination 50 Ω
HZ33
Test Cable 50 Ω (BNC-BNC) 0.5 m
HZ34
Test Cable 50 Ω (BNC-BNC) 1.0 m
10 MHz Function Generator HM8030-6
Product description, page 40
Triple Power Supply (module) HM8040-3
Operating modes
Sine, square, triangle, pulse; free running, internal sweep or external
frequency modulation, with or without DC offset
Frequency ranges
0.05 Hz…10 MHz in 8 ranges, variable: x0.09 to x 1.1 (12:1)
<0.5 %/hr or 0.8 %/24 hrs. at constant
Frequency drift:
ambient temperature
Waveform characteristics
Sine wave distortion
0.05 Hz…1 MHz:
max. 0.5 %
1…10 MHz:
max. 5 %
typ. 15 ns
Square wave rise time:
<5 % (for termination into 50 Ω)
Overshoot:
<1 % (to 100 kHz)
Triangle non-linearity:
Displays
5-digit, 7-segment LED, each 8 x 5 mm
Frequency:
Accuracy:
up to 5 Hz:
±(3 % + 3 digits)
5 Hz…10 MHz:
±(5 x 10-5 + 1 digit)
LED indicators for mHz, Hz, kHz and s
Outputs
Signal output:
Impedance:
Output voltage:
Attenuation:
2 attenuators:
Variable:
Amplitude error:
0.05 Hz…0.5 MHz:
5 Hz…10 MHz:
short-circuit proof
protected against ext. voltage up to
±45 Vdc max. (30 s)
50 Ω
10 Vpp into 50 Ω load; 20 Vpp (open circuit)
max. 60 dB
each 20 dB ±0.2 dB
0…20 dB
(sine wave/triangle)
max. 0.2 dB
max. 2.0 dB
Product description, page 41
Outputs
2 x 0…20 V/0,5 A and 5 V/1 A
Single pushbutton control of all outputs,
linear regulators with overheating
protection. Floating outputs for
parallel/serial operation,
current limit and electronic fuse
20 V Output
2 x 0…20 V, continuously variable
Setting range:
≤1 mVrms
Residual ripple:
max. 0.5 A
Output current:
Current limit/electronic fuse: 0…0.5 A continuously variable
Dynamic behaviour:
Load change 10…90 % of full load
200 µs
Recovery time:
Dyn. transient deviation: typ. 2 mV
Dyn. output impedance: 3.75 mΩ
Load change at 50 % basic load and ±10 % of full load
150 µs
Recovery time:
Dyn. transient deviation: 400 µV
Dyn. output impedance: 4 mΩ
5 V Output
Range:
Ripple and noise:
Output current:
5 V ±0.5 V screwdriver adjustment
≤1 mVrms
max. 1 A continuous, short-circuit-proof
Combined displays of 20 V outputs
2 x 3-digit displays, each can be switched
7-segment LED:
to display either voltage (V) or current (mA)
0.1 V/1 mA
Resolution:
±1 digit voltage / ±4 digit current
Display accuracy:
current limit indication
LED:
87
Specifications
Maximum limits
Reverse voltage:
Reverse current:
Voltage to ground:
Temperature control:
Miscellaneous
Safety class:
Power supply
(from mainframe):
Current output of
2 HM8040-3 with HM8001-2:
Operating temperature:
Storage temperature:
Rel. humidity:
Dimensions (W x H x D):
Weight:
25 V, each output
500 mA, each output
100 V, each terminal
If the internal temperature exceeds
75…80 °C, the HM8040-3 will be switched
off automatically.
Safety class I (EN61010-1)
1 x 8 V/1 A
2 x 24 V/530 mA
1 x 5 V/400 mA
2 x 18 Vac /100 mA
(∑ = 40 W)
sum of all channels <2 A
+5…+40 °C
-20…+70 °C
5…80 % (non condensing)
135 x 68 x 228 mm
approx. 1.07 kg
All data valid at 23 °C after 30 minutes warm-up.
Accessories supplied: Operating manual, CD
Recommended accessories:
HZ10S 5 x silicone test lead (measurement connection in black)
HZ10R 5 x silicone test lead (measurement connection in red)
HZ10B 5 x silicone test lead (measurement connection in blue)
88
Specifications
HOO10/HOO11 Serial Bus Option description, page 10
CAN/LIN Trigger and Decode in Progress
I2C Bus
Bus Configuration
Bit/Baud rate
SPI Bus
UART/RS-232 Bus
up to 10 Mbit/s (HMO352x/2524),
up to 5 Mbit/s (HMO72x…202x)
up to 25 Mbit/s (HMO352x/2524),
up to 12.5 Mbit/s (HMO72x…202x)
300, 600, 1200, 2400, 4800, 9600,
19200, 38400, 57600, 115200 Baud,
up to 62.5 Mbit/s (HMO352x/2524),
up to 31 Mbit/s (HMO72x…202x)
Number of Bit’s
7 or 10 Bit for Address ID
8 Bit for Data
32 Bit for Data
8 Bit for Data
1, 1.5, 2 Bit for Stop Bit
Polarity
n/a
Chip select, positive or negative,
or without Chipselect (2-wire SPI)
Clock rising or falling edge
Data High or Low active
High or Low active
Parity
n/a
n/a
none, odd or even
HOO10:
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2 [CH 1…4]
HOO11:
analog Channel LCH 1…2 [CH 1…4]
HOO10:
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2, external
Trigger Entry for Chip Select, [CH 1…4]
HOO11:
analog Channel LCH 1…2, external
Trigger Entry for Chip Select, [CH 1…4]
HOO10:
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2 [CH 1…4]
HOO11:
analog Channel LCH 1…2 [CH 1…4]
Event
7 or 10 Bit Address ID
7 or 10 Bit Address ID with 8 Bit Data
Start, Stop, Restart
missing Acknowledge
Address ID without Acknowledge
Data packets up to 32 Bit
with positive or negative Chip Select
or without Chip Select,
(2-wire SPI)
Data packets up to 8 Bit
Input format
Hexadecimal or Binary
Hexadecimal or Binary
Hexadecimal or Binary
HOO10:
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2, external
Trigger Entry for Chip Select, [CH1…4]
HOO11:
analog Channel LCH 1…2, external
Trigger Entry for Chip Select, [CH 1…4]
HOO10:
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2 [CH 1…4]
HOO11:
analog Channel LCH 1…2 [CH 1…4]
Bus display, color coded for
Bus display, color coded for
Trigger
Source
Hardware accelerated Decode
HOO10:
Source
digital Channel LCH 0…15 (Opt. HO3508)
analog Channel LCH 1…2 [CH 1…4]
HOO11:
analog Channel LCH 1…2 [CH 1…4]
Display
Bus display, color coded for
Yellow
Read Address ID:
Magenta
Write Address ID:
Cyan
Date:
White
Start:
White
Stop:
Green/Red
ACK/NACK:
Red
Error:
Green
Trigger Condition:
up to four lines for decoded values,
synchronous display of the Bit lines
Format
Address ID: hexadecimal
DataASCII, binary, decimal,
­hexadecimal
Date:
Start:
Stop:
Cyan
White
White
Cyan
White
White
Date:
Start:
Stop:
Red
Error:
Green
Trigger Condition:
up to four lines for decoded values,
synchronous display of the Bit lines
Red
Error:
Green
Trigger Condition:
up to four lines for decoded values,
synchronous display of the Bit lines
n/a
DataASCII, binary, decimal,
­hexadecimal
n/a
DataASCII, binary, decimal,
­hexadecimal
Differences HOO10/HOO11
Feature
HOO10
HOO11
Logic channel (LC 0…LC 15) as source for serial bus trigger and decode
x
-
Analog channel (CH 1…CH 4) as source for serial bus trigger and decode
x
x
Time synchronous decode of two serial busses
x
89
Specifications
HOO12
HOO12 CAN/LIN
for all Oscilloscopes of the HMO Series
Mixed Signal and Bus Display
CAN Bus Configuration
CAN Bus list display
CAN Bus HEX
R CAN, LIN Bus Trigger and Decode
R Hardware accelerated Decode in Realtime
R Color Coded Display of the Content for intuitive Analysis and easy Overview
R More Details of the decoded Values come visible with increasing Zoom Factor
R Bus and List Display with synchronous Display of the Data
R Decode into ASCII, Binary, Hexadecimal or Decimal Format
R Up to four Lines to show the decoded Values Comfortably
R Powerful Trigger to isolate specific Messages
R Option for all Oscilloscopes of the HMO Series, retrofittable
See page 91 for technical specifications or www.hameg.com/HOO12
90
Specifications
HOO12 CAN/LIN Serial Bus Option Option description, page 90
CAN Bus
Bus Configuration
Bit rates
LIN Bus
Pre-Defined or User-Select,
100 Bit/s…4 Mb/s (HMO352x / 2524),
100 Bit/s…2 Mb/s (HMO72x…202x)
Pre-Defined or User-Select,
100 Bit/s…4 Mb/s (HMO352x / 2524),
100 Bit/s…2 Mb/s (HMO72x…202x)
Signal Type
CAN-L or CAN-H, Single Ended or Differential Probe
(Analog Channel only)
n/a
Sample Point Range
Threshold
Polarity
Protocol Version
25…90 %
Pre-Defined or User-Select
n/a
n/a
n/a
Pre-Defined or User-Select
High or Low Aktive
1.x, 2.x, J2602, 1.x or 2.x
digital Channel LCH 0…15 (Opt. HO3508),
analog Channel LCH 1…2 [CH 1…4]
digital Channel LCH 0…15 (Opt. HO3508),
analog Channel LCH 1…2 [CH 1…4]
Event
Start of Frame (SOF),
End of Frame (EOF)
Error Frame
Error condition:
Stuff Bit Error, CRC Error,
Not Acknowledge, Form Error
Overload Frame
Data Frame (11 or 29 Bit ID)
Remote Frame (11 or 29 Bit ID)
Identifier:
0, 1, X (Don’t Care) Pattern,
Trigger when =, ≠, <, >
Identifier and Data:
ID and 64 Bit data pattern (0, 1, X),
trigger when =, ≠, <, >
Start of Frame (SOF),
Wake Up Frame
Error Frame
Error condition:
Checksum Error, Parity Error
Synchronisation Error
Identifier:
0, 1, X (Don’t Care) Pattern,
Trigger when =, ≠, <, >
Identifier and Data:
ID and 64 Bit data pattern (0, 1, X),
trigger when =, ≠, <, >
Input format
Hexadecimal or Binary
Hexadecimal or Binary
digital Channel LCH 0…15 (Opt. HO3508),
analog Channel CH 1…2 [CH 1…4]
digital Channel LCH 0…15 (Opt. HO3508),
analog Channel CH 1…2 [CH 1…4]
color coded for
color coded for
Trigger
Source
Hardware accelerated Decode
Source
Display
Bus
Start and End of Frame:
Data ID:
Remote ID:
DLC:
Data:
CRC:
ACK:
Overload:
Error:
Table
Format
White brackets
Magenta,
Yellow
White,
Cyan,
White
Green,
White,
Red
Start and End of Frame:
Break:
Synchronisation:
Identifier:
Parity:
Data:
Checksum:
Error:
Wake Up:
White brackets
Magenta,
White
Yellow,
Green,
Cyan
White,
Red,
Magenta
up to four lines for decoded values,
synchronous display of the Bit lines
up to four lines for decoded values,
synchronous display of the Bit linesy
Display of Bus 0 or 1
Display of Bus 0 or 1
Frame Number
State (Frame Type or Error Description)
Start Time,
Identifier,
DLC,
CRC,
Data
Frame Number
State (Frame Type or Error Description)
Start Time,
Identifier,
Length,
Checksum,
Data
Identifier & other: hexadecimal
Data: ASCII, binary, decimal, hexadecimal
Identifier & other: hexadecimal
Data & Checksum: ASCII, binary, decimal, hexadecimal
91
Notes
92
Index/Contact
HM400
HM800
HM6050-2
HM7042-5
HM8001-2
HM8012
HM8018
HM8021-4
HM8030-6
HM8040-3
HM8112-3
HM8115-2
HM8118
HM8123
HM8134-3
HM8135
HM8143
HM8150
HMF2525
HMF2550
HMP2020
HMP2030
HMP4030
HMP4040
HMO722
HMO724
HMO1022
HMO1024
HMO1522
HMO1524
HMO2022
HMO2024
HMO2524
HMO3522
HMO3524
HMS1000
HMS1000E
HMS1010
HMS3000
HMS3010
HO118
HO730
HO740
HO801
HO880
HO3011
HO3508/HO3516
HOO10
HOO11
HOO12
HZ10
HZ15
HZ16
HZ17
11, 62
41
17
24, 74
38, 84
39, 85
39, 86
40, 86
40, 87
41, 87
29, 76
30, 77
31, 78
32, 79
33, 80
34, 81
25, 74
35, 82
28, 83
28, 83
23, 75
23, 75
22, 76
22, 76
9, 62
9, 62
9, 64
9, 64
8, 65
8, 65
8, 67
8, 67
7, 69
6, 70
6, 70
14, 73
15, 72
14, 73
14, 73
14, 73
43
45
45
38
45
44
43
10, 44, 89
10, 44, 89
90, 91
47
47
47
47
HZ18
HZ19
HZ20
HZ21
HZ22
HZ24
HZ26
HZ31
HZ32
HZ33/HZ34
HZ33S/HZ34S
HZ42
HZ43
HZ45
HZ46
HZ51
HZ52
HZ53
HZ72
HZ99
HZ100
HZ109
HZ115
HZ154
HZ181
HZ184
HZ186
HZ188
HZ200
HZ350
HZ355
HZ520
HZ525
HZ530
HZ540
HZ547
HZ550
HZ560
HZ575
HZ809
HZ812
HZ815
HZ887
HZO10
HZO20
HZO30
HZO40
HZO41
HZO50
HZO51
HZO90
HZO91
HZP91
47
47
48
48
49
49
49
48
48
48
48
58
58
58
58
50
51
51
49
59
52
52
52
50
56
56
56
56
50
50
50
57
54
19
18
57
18
57
55
56
55
56
55
51
51
51
53
53
54
54
59
59
59
We provide a worldwide dealer network, in order to offer best local support. For questions about our
products, please visit www.hameg.com/dealer to find your local contact information.
Service:
Tel:
+ 49 (0) 6182 800 500
Fax:
+ 49 (0) 6182 800 501
E-Mail: [email protected]
Director Service:
Dipl.-Ing. (FH) Uwe Scholz
Repair order processing:
Rosalinde Andraschky
Sales:
Tel:
+ 49 (0) 6182 800 300
Fax:
+ 49 (0) 6182 800 301
E-Mail: [email protected]
Director Sales:
Thomas Modenbach
Sales Department:
Gerlinde Glaser, Brigitte May, Carmen Sehnert
Product Management:
Tel:
+ 49 (0) 6182 800 700
Fax:
+ 49 (0) 6182 800 701
E-Mail: [email protected]
Director Product Management:
Dipl.-Ing. Andreas Grimm
Support Line:
Dipl.-Ing. (FH) Dennis Holderbusch,
Dipl.-Ing. (FH) Ilka Beringer
93
Great Value in
Test & Measurement
German Quality
for more than 50 years
With Compliments
www.hameg.com
4A-W109-12EN · C&E · Subject to change without notice · © HAMEG Instruments GmbH® · DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · www.hameg.com/dealer
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement