1319 Data Sheet Instruction
REVISIONS
DESCRIPTION
REV
ECO
001
002
003
004
4153 PRODUCTION RELEASE
5188 CHANGE TRQ FRM 60±10 TO 50±5 IN/LBS & ADD e-MARK TO LABEL
5355 ADD TRANSIENT PROTECTION
5369 REDUCE ESD SPECIFICATION FROM 15kV to 8kV
DATE
BY
7/30/04
7/16/08
1/16/09
2/6/09
BF
BF
JT
JT
1318/1319
24V BATTERY SEPARATOR
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES [MM]
.XX ± .10 [X.X ± 2.5]
.XXX ± .030 [X.XX ± 0.76]
INTERPRET GEOMETRIC DIMENSIONS AND
TOLERANCING PER ASME Y14.5-1994
DRAWINGS IN THIS DOCUMENT ARE NOT TO SCALE
TOLERANCES ARE:
APPROVALS
DRAWN BY
PROPRIETARY
THIS DRAWING IS THE PROPERTY OF SURE POWER
INC. and shall not be copied, reproduced, lent, or disposed
of, nor used for any purpose other than that for which it is
specifically provided without written permission of
SURE POWER INC.
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR,100A
SPECIFICATION OUTLINE
DATE
JZD
1/7/09
PROJECT ENG APPROVAL
ENG MANAGER APPROVAL
SALES/MRKTG APPROVAL
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
1
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
OVERVIEW
The 1318 and 1319 are 100A battery separator modules with an integrated relay for 28V systems—the 1318 is
unidirectional and the 1319 is bidirectional. The 1318 monitors only the main battery and charges the auxiliary
battery if the main battery is above the connect threshold. The 1319 monitors both the main and auxiliary battery
banks. If either battery bank is above the connect threshold, the relay connects the two banks together. If the
batteries are below the disconnect threshold, the unit will open the relay. The connect threshold is set to a
nominal voltage of 26.8V, which would only be reached when the charging system is operational. This will cause
the relay to only close when the charging system is operational, charging both banks of batteries. The disconnect
voltage is set to a nominal 25.7V, which is near the full charge resting voltage of the batteries. This will cause the
relay to be opened shortly after the engine is stopped, attempting to preserve 100% of the starting battery
capacity for engine cranking.
UNIT CONNECTIONS
The unit has five connections (see Connection Diagram for locations):
1.
Main Battery connection
This is the high current connection to the main battery bank. This connection is made directly to the relay.
Product labeling refers to this as the MAIN BAT connection. The unit is powered from the main battery
connection or the auxiliary battery connection, drawing power from whichever has the higher voltage.
2.
Auxiliary Battery connection
This is the high current connection to the auxiliary battery bank. Product labeling refers to this as the AUX
BAT connection. The unit is powered from the main battery connection or the auxiliary battery connection,
drawing power from whichever has the higher voltage.
3.
Ground
This is the unit ground connection.
4.
Start signal input
This is the input for engine start signal override. When power is applied to this input, the relay will close if the
Aux. Battery is no less than 0.85 Volts below the Main battery (Main – 0.85V).
5.
Start lamp output
This is the start lamp drive output. The start lamp is powered when the start signal input has caused the relay
to close. This output can source up to 250mA to an incandescent lamp. For LED type indicator, see
MAXIMUM RATINGS, START LAMP drive current.
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
2
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
ELECTRICAL
MAXIMUM RATINGS
Maximum ratings establish the maximum electrical rating to which the unit may be subjected.
Characteristic
Symbol
Parameter
VINMAX
32
V
Damage to relay MAY occur if repeatedly operated above 32V
Standoff Voltage
VSO
40
V
5-minute duration. Applies to AUX BATT, MAIN BATT, and
START SIGNAL terminals only.
Time at Standoff
tSO
Continuous
V
Control is protected from continuous operation at 40V
Continuous Relay
current
IR,MAXC
100
A
Inrush Relay
current
IR,MAXI
400
A
START LAMP
drive current
ILAMP
250
mA
ESD
VESD
±8kV contact
±8kV air
V
Input Voltage
Unit
Notes
30 seconds on, 6 minutes off duty cycle.
Protected from short circuits on output—tested at 16V. This
output is designed for an incandescent lamp. A current-limiting
resistor must be used in series with an LED indicator (1k-Ohm,
½ W recommended).
Ref. SAE J1113-13. All terminals in any combination.
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
3
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
All terminals protected against reverse polarity except reversal of one of the battery polarities. (Relay is
not current limited. Connecting batteries of opposite polarity will damage relay).
ELECTRICAL CHARACTERISTICS
Unless otherwise stated, conditions apply to full operational temperature range and full voltage range (9V to 16V)
Characteristic
Normal Input Voltage
Symbol MIN
VIN
TYP
18
Contact life
MAX Unit
32
25,000
V
Notes
Proper relay operation not guaranteed below
18V.
Cyc
100A resistive load.
Connect Voltage
VCON
26.8
V
Nominal minimum voltage required at main
battery terminal for attached relay to be
energized.
Disconnect Voltage
VDCON
25.7
V
Nominal maximum voltage required at main
battery terminal for attached relay to be deenergized.
Quiescent Current
IQUES
3.0
mA
Relay drive current
IRELAY
0.5
A
START LAMP
output voltage
VLAMP
Battery
voltage –
2.2V
V
START SIGNAL
threshold voltage
VSST
71% of
Battery
Connect debounce
Disconnect
debounce
tCD
tDD
14
10
26.0V, relay off, Start Signal input open or
grounded.
2.2V is the typical voltage drop from Main
Battery to the Start Lamp output (Battery
voltage being the higher of the two battery
voltages).
V
Nominal minimum voltage required on START
SIGNAL input for the input to activate.
S
When the battery voltage rises above the
connect voltage and the relay closes, this is
the minimum amount of time it will stay
closed, regardless of the battery voltages.
S
When the battery voltage falls below the
disconnect voltage and the relay opens, this is
the minimum amount of time it will stay open,
regardless of the battery voltages.
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
4
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
ENVIRONMENTAL SPECIFICATIONS
Control module is encapsulated in epoxy, relay is water resistant.
Characteristic
Parameter
Units
Operational Temperature Range (Control)
-40 TO +85
°C
Operational Temperature Range (Relay)
-28 TO +48
°C
TRANSIENT IMMUNITY/EMISSIONS
Characteristic
Level
Notes
Inductive Load Switching +400V/-600V
Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94
Mutual Coupling
±300V
Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94
Load Dump
122V
Ref. SAE J1455, Section 4.11.2.2.2 Rev 8/94
ISO Immunity
Per standard1
ISO 7637-2:2004
ISO Emissions
Per standard1
ISO 7637-2:2004
1
Sufficient to apply E mark.
RADIATED EMISSIONS
Characteristic
Radiated Emissions
Narrowband
30MHz to 1GHz
Radiated Emissions
Broadband
30MHz to 1GHz
Level
Notes
Per
standard2
ISO 13766:1999, section 6.5
EN 13309:2000, section 4.6
EU Directive 72/245/EEC as amended
Per
standard2
ISO 13766:1999, section 6.4
EN 13309:2000, section 4.5
EU Directive 72/245/EEC as amended
2
Sufficient to apply CE mark.
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
5
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
CONNECTION DIAGRAM
For Automatic Operation
Connect to Start Position of
ignition Switch (see step 8)
Auxiliary Start Activation
Optional Conections
Auxiliary Start
Indicator Light
Blue
Brown
Black
Main Battery
For Manual Operation
Connect as Shown Here
Momentary Boost
Switch Mount
on Dash
Auxiliary Battery
Main Loads
Auxiliary Loads
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
6
OF
7
F04-019-008
REVISIONS
- SEE SHEET 1 -
UNIT DIMENSIONS
2.15 [54.6]
(1.075 [27.31])
5/16X24
(.395 [10.03])
1.050 [26.67]
(.900 [22.86])
2.80 [7.11]
(2.53 [64.3])
(.600 [15.24])
2X TORQUE NOT TO EXCEED 55 IN-LBS
(A BACK-UP WRENCH MUST BE USED TO HOLD
THE BOTTOM NUT STATIONARY DURING
INSTALLATION)
.400 [10.16]
(.325 [8.26])
(1.45 [36.8])
(.325 [8.26])
(3.11 [79])
(3.18 [80.7])
Weight: Under 1 Lb. (0.45Kg)
Recommended Mounting: Coil terminals up or horizontal
TITLE
MODEL NO: 1318/1319
24V BATT SEPARATOR, 100A
SPECIFICATION OUTLINE
SIZE
A
SCALE:
CAGE CODE NO. DRAWING NO.
55156
NONE
REV
1318_1319
FILE:
1318_1319-004
004
SHEET
7
OF
7
F04-019-008