Dewetron D300 D3PC-4, D3PC-8, -16, MDAQ -SUB-V200-BNC, -SUB-V200-D, -SUB-ACC-BNC, -SUB-ACC-A-BNC, -SUB-STG-D, -SUB-BRIDGE-D, SC4 -10mV-BNC, SC4 -100mV-BNC, SC4 -1V-BNC, SC4 -10V-BNC, SC4 -20V-BNC, SC4 -40V-BNC, SC4 -100V-B, SC4 -200V-B, SC4 -400V-B, SC4 -1000V-B Product selection guide
Below you will find brief information for D300 D3PC-4, D300 D3PC-8, D300 D300-16. The D300 series are data acquisition systems that can be configured in multiple ways, including as a noise and vibration analyzer, a scope, or a BUS recorder/analyzer. The D300-16 can also be expanded to have up to 16 isolated SC4 series basic signal conditioners or 16 MDAQ differential signal conditioning channels.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
12
D300-16 with MDAQ conditioners D300 series www.dewamerica.com/Products/D300 OVERVIEW The D300 is our most affordable and flexible data acquisition and computing platform. It can be configured in several basic ways: ◙◙ As an 8-channel noise and vibration analyzer (ORION-0824-200 A/D card inside): D3PC-8 ◙◙ As a 4-channel noise and vibration analyzer (ORION-0424-200 inside): D3PC-4 ◙◙ With up to 16 ISOLATED SC4 series basic signal conditioners, in blocks of four channels (any four can be installed), and any A/D card inside ◙◙ With up to 16 MDAQ DIFFERENTIAL signal conditioning channels, any two MDAQ-SUB blocks of 8 channels, and any A/D card inside ◙◙ With any ZTEC series SCOPE card, as 2-channel PC-based scope ◙◙ With any ARINC or 1553 interface card, as a highly portable aircraft BUS recorder/analyzer There are many additional instruments that can be built on the D300 platform - it’s just that flexible. And we have done everything to make it as affordable as possible without sacrificing quality or reliability. 12 Dewetron PRODUCT SELECTION GUIDE ◙◙ Highly configurable and economical system ◙◙ Choose from direct inputs, SC4 isolated conditioners, or any two MDAQ-SUB series signal conditioners ◙◙ Full power DEWE computer inside ◙◙ One half-length PCI slot inside ◙◙ Compatible with ORION and AD series A/D cards ◙◙ 500 GB removable HDD ◙◙ Keyboard and mouse are included ◙◙ VGA output connector (supports XGA resolution displays) ◙◙ Wide range DC power input, plus a convenient AC/DC adapter is included ◙◙ Metal door protects the computer interfaces (ethernet, USB, VGA, A/V, etc.) ◙◙ Ruggedized construction, MIL-STD, CE MARK, and more ◙◙ Small footprint D3PC available also as a pure computer or PCI bridge host platform ◙◙ Made in USA ◙◙ Full year warranty MDAQ differential conditioners The D300 model is compatible with our MDAQ differential conditioners. You may choose any two of the MDAQ-SUB 8-channel conditioners to be installed on the front panel, with BNC or DSUB connectors. The most popular MDAQ-SUB is the STG-D, which is a strain/bridge universal type signal conditioner, because in addition to handling any kind of strain gage and low voltage by itself, it also accepts our MSI multiple sensor adapters, which convert each input to something different, such as IEPE accelerometers, charge accelerometers, ±200V signals, RTDs, and even high bandwidth thermocouples. But there are other MDAQ-SUBs, including 8 channel IEPE accelerometers, 8 channels of voltage from ±125 mV to ±200V, and more. SC4 ISOLATED signal conditionERS When configured for SC4 conditioners, you can pick any four of our ISOLATED 4-channel conditioners, for a total of 16 inputs. There are SC4 conditioners for different voltage levels, different strain gage conditioners in full or half bridge, with various thermocouples, and more. EPAD2 series conditioners can be added to either version, allowing you to expand your D300 to more channels, adding slow channels for temperature, as well as DC voltages and currents, in blocks of eight channels. D300 with SC4 signal conditioner panels: 4 thermocouples, four full or half bridge strain gage, and four voltage inputs. All are isolated to 1500Vrms. D3PC-4 and D3PC-8 models The smallest DEWETRON systems ever made are these two: The D3PC-4 features four IEPE/low-voltage inputs and an advanced counter input. The D3PC-8 features eight IEPE/low-voltage inputs, two advanced counter inputs, 8 DIO lines ... and you can expand this model to have two CAN BUS interfaces and more digital inputs/counters. You can also sync multiple systems together to make a larger channel count system! Dewetron PRODUCT SELECTION GUIDE 13 D3PC-4 and D3PC-8 models There are several basic configurations of the D300, starting with direct inputs from the A/D card, or ISOLATED SC4 modules, or DIFFERENTAL MDAQ conditioners... DIRECT INPUTS FROM ORION CARDS, 4-channel instrument D3PC-4 ◙◙ 4 x BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support ◙◙ 24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters ◙◙ 4 different input ranges: ±0.1, ±0.5, ±2, ±10 V ◙◙ Single-ended or differential configuration, AC (0.15 or 3.4 Hz) or DC coupled ◙◙ SUB-D-9 connector with 1 synchronous advanced counter / encoder with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, AC/DC coupling, plus an external trigger input (TTL with pull-up) ◙◙ Includes DS-7-SE acquisition and analysis software ◙◙ Nothing needs to be added to complete this system (except a display) D3PC-4 upgrades RAM-2048-3072 HARD DISK upgrades Software upgrades CAL-ORION-04-NIST-4 USB-ARINC or -1553 Upgrade the PC RAM from 1 GB to 2 GB or 3 GB Change the HDD from a 500 GB spinning disk to a solid state drive: 32, 64, or 128 GB. Also, get a spare HDD Upgrade the basic version of DS-7 from -SE to -PROF, or -DSA. NIST traceable calibration data for the ORION-0424-200 card within the D300-4 Add a USB interface for ARINC 429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGINARINC/1553 D3PC-4 options & accessories MOB-DISP-17 0424-CBL-DIG Software options ACCELS GPS sensor VIDEO camera Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution Mating cable for the digital input connector of the ORION0424-200 card, 2 meters, with stripped and tinned leads. Add software options like order tracking, sound level meter, modal analysis, balancing, and more. Dewetron offers DYTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4 You can add a simple USB GPS sensor with 1 Hz update rate, or one of our 20/100 Hz GPS sensors for incredible precision. A common webcam can be connected to the USB port, allowing you to record video in sync with your data D3PC-4 and -D3PC8 typical applications BRAKE NOISE testing HUMAN VIBRATION testing MODAL testing GENERAL PURPOSE testing The four inputs can be used with IEPE microphones to measure SOUND very accurately. Add a GPS sensor to correlate the data with vehicle speed, position, heading, and other parameters. Add seat and other accelerometers with the HUMAN VIBE software option, to study the effects of vibration on human subjects. Ideal for machinery, vehicles, and other applications. With the synchronous counter input and four IEPE inputs, the D3PC-4 makes the perfect small channel count modal analysis instrument. Just add DS-OPT-FRF software option and some IEPE accelerometers. Any basic data acquisition application where you need a small footprint self contained data acquisition instrument with great dynamic specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point! 14 Dewetron PRODUCT SELECTION GUIDE DIRECT INPUTS FROM ORION CARDS, 8-channel instrument D3PC-8 D3PC-8 upgrades ◙◙ 8 analog voltage or ICP (4 / 8 mA) inputs with sensor cable break detection and TEDS support ◙◙ 24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, anti-aliasing filters ◙◙ 4 different input ranges: ±0.1, ±0.5, ±2, ±10 V ◙◙ Single-ended or differential configuration, AC or DC coupled ◙◙ 8 synchronous TTL digital I/Os (upgradable to 25V protection via UP-ORION-CTR8) ◙◙ 2 synchronous advanced counter / encoder or 8 digital inputs with programmable threshold levels (0 ~ 40 V), input voltage range -35 to 60 V, AC/DC coupling ◙◙ Includes DS-7-SE acquisition and analysis software ◙◙ Nothing needs to be added to complete this system (except a display) RAM-2048-3072 HARD DISK upgrades UP-ORION-CAN2 UP-ORION-CTR8 UP-ORION-200-1000-8 USB-ARINC or -1553 Upgrade the PC RAM from 1 GB to 2 GB or 3 GB Change the HDD from a 500 GB spinning disk to a solid state drive: 32, 64, or 128 GB. Also, get a spare HDD Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters Upgrade the A/D card from 200 kS/s max to 1000 kS/s max (@ 16-bit instead of 24-bit) Add a USB interface for ARINC 429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGINARINC/1553 D3PC-8 options & accessories MOB-DISP-17 CTR-CBL-05 Software options ACCELS GPS sensor VIDEO camera Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution Connection cable from counter input (FGG.1B.307) to open end, length 5 m. Add software options like order tracking, sound level meter, modal analysis, balancing, and more. Dewetron offers DYTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4 You can add a simple USB GPS sensor with 1 Hz update rate, or one of our 20/100 Hz GPS sensors for incredible precision. A common webcam can be connected to the USB port, allowing you to record video in sync with your data SOUND analysis testing MODAL testing Eight high-dynamic microphone inputs with anti-aliasing filtering makes the D300-8 ideal for all kinds of sound analyses. Great for working in an anechoic chamber or in the field.Add the DS-OPT-SNDLVL software option and IEPE microphones. With the synchronous counter input and eight IEPE inputs, the D300-8 makes the perfect medium channel count modal analysis instrument. Just add DS-OPT-FRF software option and some IEPE accelerometers. Dewetron PRODUCT SELECTION GUIDE 15 D300-8 with SC4/MDAQ conditioners The D300-8 is compatible with 8 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL MDAQ conditioners... WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS D300-8 ◙◙ 8 channel ORION-0824-200 PCI A/D card built-in ◙◙ 24-bit resolution, simultaneous sampling, 200 kS/s per channel 8 synchronous TTL digital I/Os ◙◙ 2 synchronous TTL counter / encoder or 8 TTL digital inputs ◙◙ Includes DS-7-SE acquisition and analysis software ◙◙ Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs OR please add 16 channels of SC4 series signal conditioners (MDAQ and SC4 series conditioners cannot be mixed) D300-8 upgrades RAM-2048-3072 HARD DISK upgrades Software upgrades USB-ARINC or -1553 Upgrade the PC RAM from 1 GB to 2 GB or 3 GB Change the HDD from a 500 GB spinning disk to a solid state drive: 32, 64, or 128 GB. Also, get a spare HDD Upgrade the basic version of DS-7 from -SE to -PROF, or -DSA. Add a USB interface for ARINC 429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGINARINC/1553 A/D card upgrades UP-ORION-200-1000-8 UP-ORION-CAN2 UP-ORION-CTR8 Upgrade the A/D card from 200 kS/s max to 1000 kS/s max (@ 16-bit instead of 24-bit) Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters D300-8 options & accessories MOB-DISP-17 CTR-CBL-05 Software options ACCELS GPS sensor VIDEO camera Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution Connection cable from counter input (FGG.1B.307) to open end, length 5 m. Add software options like order tracking, sound level meter, modal analysis, balancing, and more. Dewetron offers DYTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4 You can add a simple USB GPS sensor with 1 Hz update rate, or one of our 20/100 Hz GPS sensors for incredible precision. A common webcam can be connected to the USB port, allowing you to record video in sync with your data 16 Dewetron PRODUCT SELECTION GUIDE FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners: To configure the D300-8 with MDAQ differential signal conditioning, simply order the appropriate PANEL - either the 2.0U high one which can hold MDAQs with DSUB connectors (or half DSUB and half BNC), or the 1.5U one which can hold up to 16 BNC connectors.The 1.5U high one, there is a 0.5U high space still available for other PANELS that you might want to have us install. 1.5U-PANEL-MDAQ-BNC 2.0U-PANEL-MDAQ D300 2.0U-PANEL-MDAQ Accepts any of our 8 channel MDAQ-SUB modules, regardless of connector type. When this PANEL is installed, all 8 channels from the standard A/D card are connected to these 8 signal conditioning inputs. See below for MDAQ-SUB 8-channel conditioners. OR... 1.5U-PANEL-MDAQ-BNC Accepts any of our 8 channel MDAQ-SUB modules with BNC connectors only. When this PANEL is installed, all 8 channels from the standard A/D card are connected to these 8 signal conditioning inputs. See below for MDAQ-SUB 8-channel conditioners. MDAQ-SUB 8-channel conditioners (choose any ONE of these for the D300-8) MDAQ-SUB-V200-BNC MDAQ-SUB-V200-D MDAQ-SUB-ACC-BNC MDAQ-SUB-ACC-A-BNC MDAQ-SUB-STG-D MDAQ-SUB-BRIDGE-D 8 channel voltage module 16 selectable ranges from ±0.125V to ±200V. Differential inputs. CMV ±250 V. Accuracy ±0.05%. Bandwidth 300 kHz. BNC connectors (8) 8 channel voltage 16 selectable ranges from ±0.125V to ±200V. Differential inputs. CMV ±250V. Accuracy ±0.05%. Bandwidth 300 kHz ±15 VDC fixed sensor supply and programmable 0~12 VDC sensor supply TEDS support 9-pin DSUB connectors (8) 8 channel IEPE / low-voltage input, selectable ranges of ±10, 5, 2.5, 1.25, 1, 0.5, 0.25 and 0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V. AC or DC coupling. Differential / single-ended (voltage mode only). Accuracy ±0.05%. Bandwidth DC to 300 kHz. Selectable 3.4 Hz high-pass filter. TEDS support. BNC connectors (8) 8 channel IEPE / low-voltage input, selectable ranges of ±10, 5, 2.5, 1.25, 1, 0.5, 0.25 and 0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V. AC or DC coupling. Differential (IEPE mode); single-ended (voltage mode). Accuracy ±0.05%. Bandwidth DC to 300 kHz. Selectable 2 programmable high pass filters: 0.16 Hz, 3.4 Hz. TEDS support. BNC connectors (8) 8 channel strain / low-voltage input. Modes: full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or voltage. Full bridge sensors 120 Ω to 10 kΩ. Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors internal 50 kΩ and 100 kΩ shunt resistors 14 selectable ranges from ±0.5 to ±1000 mV/V (@ 5 V excitation) Voltage mode ranges from ±5 mV to ±10 V Bandwidth DC to 30 kHz Excitation voltage from 0~12 VDC. TEDS support 9-pin DSUB connectors (8) 8 channel bridge / low-voltage input. Modes: full bridge, 1⁄2 bridge Full bridge sensors 120 Ω to 10 kΩ. Internal completion for 1⁄2 bridge sensors AC/DC coupling 14 selectable ranges from ±0.5 to ±1000 mV/V (@ 5 V excitation) Voltage mode ranges from ±5 mV to ±10 V Bandwidth DC to 30 kHz Excitation voltage from 0~12 VDC. TEDS support 9-pin DSUB connectors (8) Alternate version: MDAQ-SUB-ACC-BNC-S1 Same as MDAQ-SUB-ACCBNC, except that the high-pass filter is 1.6 Hz (typical for structural analysis, modal, and human body vibration) Dewetron PRODUCT SELECTION GUIDE 17 D300-16 with SC4/MDAQ conditioners The D300-16 is compatible with 16 channels of ISOLATED SC4 modules, or 16 channels of DIFFERENTIAL MDAQ conditioners... WITH MDAQ DIFFERENTIAL or SC4 ISOLATED SIGNAL CONDITIONERS D300-16 ◙◙ 16 channel ORION-1616-100 PCI A/D card built-in ◙◙ 16-bit resolution, simultaneous sampling, 100 kS/s per channel 8 synchronous TTL digital I/Os ◙◙ 2 synchronous TTL counter / encoder or 8 TTL digital inputs ◙◙ Includes DS-7-SE acquisition and analysis software ◙◙ Please add any 2.0U-PANEL-MDAQ (or 1.5U-PANEL-MDAQ) plus 2 x MDAQ-SUBs OR please add 16 channels of SC4 series signal conditioners (MDAQ and SC4 series conditioners cannot be mixed) D300-16 upgrades RAM-2048-3072 HARD DISK upgrades UP-ORION-CAN2 UP-ORION-CTR8 Software upgrades USB-ARINC or -1553 Upgrade the PC RAM from 1 GB to 2 GB or 3 GB Change the HDD from a 500 GB spinning disk to a solid state drive: 32, 64, or 128 GB. Also, get a spare HDD Adds two synchronous highspeed CAN BUS interfaces, including DS-OPT-CAN software option, 2 x DB9’s Upgrade from 8 TTL I/O lines to 25V protected lines, and from 2 advanced counters, to 8 advanced counters Upgrade the basic version of DS-7 from -SE to -PROF, or -DSA. Add a USB interface for ARINC 429 or MIL-STD-1553 interfaces to your system. Requires software option PLUGINARINC/1553 A/D card upgrades UP-ORION-16-22 UP-ORION-16-24 UP-ORION-100-500 UP-ORION-100-1000 DN-ORION-AD16-1000-16 Upgrade the A/D card from 16-bit to 22-bit with anti-aliasing filters (ORION-1622-100). Max SR is still 100 kS/s/ch Upgrade the A/D card from 16-bit to 24-bit with antialiasing filters (ORION-1624200). Max SR increases to 200 kS/s/ch Upgrade the A/D card from max SR of 100 kS/s/ch to 500 kS/s/ ch (ORION-1616-500). Bit resolution remains at 16-bits. Upgrade the A/D card from max SR of 100 kS/s/ch to 1000 kS/s/ ch (ORION-1616-1000). Bit resolution remains at 16-bits. Downgrade the standard A/D card to a multiplexed type, 16 channels, 1000 kS/s (aggregate) max. SR. D300-16 options & accessories MOB-DISP-17 CTR-CBL-05 Software options ACCELS GPS sensor VIDEO camera Ruggedized mobile display with capacitive touchscreen, 17” diag, XGA resolution Connection cable from counter input (FGG.1B.307) to open end, length 5 m. Add software options like order tracking, sound level meter, modal analysis, balancing, and more. Dewetron offers DYTRAN IEPE accelerometers, which are perfectly suited to the D3PC-4 You can add a simple USB GPS sensor with 1 Hz update rate, or one of our 20/100 Hz GPS sensors for incredible precision. A common webcam can be connected to the USB port, allowing you to record video in sync with your data 18 Dewetron PRODUCT SELECTION GUIDE FACTORY INSTALLED MDAQ DIFFERENTIAL signal conditioners: To configure the D300-16 with MDAQ differential signal conditioning, simply order the appropriate PANEL - either the 2.0U high one which can hold MDAQs with DSUB connectors (or half DSUB and half BNC), or the 1.5U one which can hold up to 16 BNC connectors.The 1.5U high one, there is a 0.5U high space still available for other PANELS that you might want to have us install. 1.5U-PANEL-MDAQ-BNC 2.0U-PANEL-MDAQ D300 2.0U-PANEL-MDAQ Accepts any two of our 8 channel MDAQ-SUB modules, regardless of connector type. When this PANEL is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs. See below for MDAQ-SUB 8-channel conditioners. OR... 1.5U-PANEL-MDAQ-BNC Accepts any two of our 8 channel MDAQ-SUB modules with BNC connectors only. When this PANEL is installed, all 16 channels from the standard A/D card are connected to these 16 signal conditioning inputs. See below for MDAQ-SUB 8-channel conditioners. MDAQ-SUB 8-channel conditioners (choose 2, or 2 of the same one) MDAQ-SUB-V200-BNC MDAQ-SUB-V200-D MDAQ-SUB-ACC-BNC MDAQ-SUB-ACC-A-BNC MDAQ-SUB-STG-D MDAQ-SUB-BRIDGE-D 8 channel voltage module 16 selectable ranges from ±0.125V to ±200V. Differential inputs. CMV ±250 V. Accuracy ±0.05%. Bandwidth 300 kHz. BNC connectors (8) 8 channel voltage 16 selectable ranges from ±0.125V to ±200V. Differential inputs. CMV ±250V. Accuracy ±0.05%. Bandwidth 300 kHz ±15 VDC fixed sensor supply and programmable 0~12 VDC sensor supply TEDS support 9-pin DSUB connectors (8) 8 channel IEPE / low-voltage input, selectable ranges of ±10, 5, 2.5, 1.25, 1, 0.5, 0.25 and 0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V. AC or DC coupling. Differential / single-ended (voltage mode only). Accuracy ±0.05%. Bandwidth DC to 300 kHz. Selectable 3.4 Hz high-pass filter. TEDS support. BNC connectors (8) 8 channel IEPE / low-voltage input, selectable ranges of ±10, 5, 2.5, 1.25, 1, 0.5, 0.25 and 0.125 V; sensor power 4 / 8 mA selectable. CMV ±12 V. AC or DC coupling. Differential (IEPE mode); single-ended (voltage mode). Accuracy ±0.05%. Bandwidth DC to 300 kHz. Selectable 2 programmable high pass filters: 0.16 Hz, 3.4 Hz. TEDS support. BNC connectors (8) 8 channel strain / low-voltage input. Modes: full bridge, 1⁄2 bridge, 1⁄4 bridge 120 Ω, 1⁄4 bridge 350 Ω or voltage. Full bridge sensors 120 Ω to 10 kΩ. Internal completion for 1⁄2 bridge and 1⁄4 bridge sensors internal 50 kΩ and 100 kΩ shunt resistors 14 selectable ranges from ±0.5 to ±1000 mV/V (@ 5 V excitation) Voltage mode ranges from ±5 mV to ±10 V Bandwidth DC to 30 kHz Excitation voltage from 0~12 VDC. TEDS support 9-pin DSUB connectors (8) 8 channel bridge / low-voltage input. Modes: full bridge, 1⁄2 bridge Full bridge sensors 120 Ω to 10 kΩ. Internal completion for 1⁄2 bridge sensors AC/DC coupling 14 selectable ranges from ±0.5 to ±1000 mV/V (@ 5 V excitation) Voltage mode ranges from ±5 mV to ±10 V Bandwidth DC to 30 kHz Excitation voltage from 0~12 VDC. TEDS support 9-pin DSUB connectors (8) Alternate version: MDAQ-SUB-ACC-BNC-S1 Same as MDAQ-SUB-ACCBNC, except that the high-pass filter is 1.6 Hz (typical for structural analysis, modal, and human body vibration) Dewetron PRODUCT SELECTION GUIDE 19 D300-8 / -16 with SC4 conditioners RACKS for FACTORY INSTALLED SC4 ISOLATED signal conditioners: If you want to configure the D300-16 with SC4 isolated signal conditioning, simply select any four of the SC4 conditioners, which include the 0.5U high panel that the connectors are mounted on, as well as the conditioners that are installed inside the system. You can choose any combination of SC4 modules, including all four the same, or all different, etc. Most SC4 conditioners are isolated to 1500V RMS. 0.5U PANEL SLOT 1 0.5U PANEL SLOT 2 0.5U PANEL SLOT 3 0.5U PANEL SLOT 4 D300 SC4 series ISOLATED 4-channel conditioners - choose any combination of four LOW VOLTAGE SC4-10mV-BNC SC4-100mV-BNC SC4-1V-BNC SC4-10V-BNC SC4-20V-BNC SC4-40V-BNC Analog input channels 4 4 4 4 4 4 Full scale input range ±10 mV ±100 mV ±1 V ±10 V ±20 V ±40 V Bandwidth (-3 dB point) 10 kHz 10 kHz 10 kHz 10 kHz 10 kHz 10 kHz CMV (isolation) 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) CMR (50 or 60 Hz) 100 dB 100 dB 100 dB 100 dB 100 dB NMR (–3 dB at 10 kHz) 120 dB per decade above 10kHz Accuracy ±0.03% span ±0.03% span ±0.03% span ±0.03% span ±0.03% span ±0.03% span Linearity ±0.01% span ±0.01% span ±0.01% span ±0.01% span ±0.01% span ±0.01% span Input protection 240 Vrms max. 240 Vrms max. 240 Vrms max. 240 Vrms max. 240 Vrms max. 240 Vrms max. Output protection Continuous short to ground Continuous short to ground Continuous short to ground Continuous short to ground Continuous short to ground Continuous short to ground Input resistance Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal/Power off/ Overload: 650 kΩ minimum Normal/Power off/ Overload: 650 kΩ minimum Normal/Power off/ Overload: 650 kΩ minimum Connectors: Four insulated BNC input connectors on a 0.5U panel 100 dB HIGH VOLTAGE SC4-100V-B SC4-200V-B SC4-400V-B SC4-1000V-B Analog input channels 4 4 4 4 Full scale input range ±100 V ±200 V ±400 V ±1000 V Bandwidth (-3 dB point) 10 kHz 10 kHz 10 kHz 10 kHz CMV (isolation) 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) CMR (50 or 60 Hz) 100 dB NMR (–3 dB at 10 kHz) 120 dB per decade above 10kHz Accuracy ±0.03% span Linearity ±0.01% span Input protection 100 dB 100 dB 100 dB ±0.03% span ±0.03% span ±0.03% span ±0.01% span ±0.01% span ±0.01% span 240 Vrms max. 240 Vrms max. 240 Vrms max. 240 Vrms max. Output protection Continuous short to ground Continuous short to ground Continuous short to ground Continuous short to ground Input resistance Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal 200 MΩ, Power off: 40 kΩ, Overload: 40 kΩ Normal/Power off/ Overload: 650 kΩ minimum Connectors: Four insulated banana jack input connectors on a 0.5U panel Note - when SC4 high voltage modules are used, the D300-16 is limited to 8 dynamic input channels. 20 Dewetron PRODUCT SELECTION GUIDE RTD SC4-RTD-P1002W3W SC4-RTD-P1004W CURRENT SC4-LA-4-20mA Analog input channels 4 Analog input channels 4 4 Full scale range: 4 - 20 mA Linearization Fully linearized Fully linearized Bandwidth (-3 dB point) 4 Hz Full scale range: -100°C to +200°C -100°C to +200°C CMV (isolation) Sensor compatibility 100 Ω Platinum RTD 100 Ω Platinum RTD Wiring modes 2 and 3-wire configurations only 4-wire configuration only 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) Bandwidth (-3 dB point) 4 Hz 4 Hz NMR 95dB at 60Hz, 90dB at 50Hz CMV (isolation) 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) Accuracy ±0.03% Span Input protection 240 Vrms max. Connectors: Four insulated DB9 input connectors on a 0.5U panel NMR 95 dB at 60 Hz, 90 dB at 50 Hz Accuracy ±0.18°C ±0.18°C Input protection 240 Vrms max. 240 Vrms max. Connectors: Four insulated DB9 input connectors on a 0.5U panel THERMOCOUPLES SC4-TH-J SC4-TH-K SC4-TH-T Analog input channels 4 4 4 Bandwidth (-3 dB point) 4 Hz 4 Hz 4 Hz CMV (isolation) 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) Linearization Fully linearized with automatic CJC NMR 95 dB at 60 Hz, 90 dB at 50 Hz Accuracy ±0.08% (±0.61°C) ±0.08% (±0.61°C) ±0.08% (±0.61°C) Input protection 240 Vrms max. 240 Vrms max. 240 Vrms max. Connectors: Four insulated miniature thermocouple input connectors on a 0.5U panel BRIDGE/STRAIN SC4-BRF-3V3mV SC4-BRF-10V2mV SC4-BRH-3V3mV Analog input channels 4 4 4 Bridge mode FULL bridge FULL bridge HALF bridge HALF bridge Full scale range: 100 Ω to 10 kΩ 300 Ω to 10 kΩ 100 Ω to 10 kΩ 300 Ω to 10 kΩ Excitation Voltage 3 V 10 V 3 V 10 V Sensitivity 3 mV/V 2 mV/V 3 mV/V 3 mV/V Bandwidth (-3 dB point) 10 kHz 10 kHz 10 kHz 10 kHz CMV (isolation) 1500 Vrms maximum continuous (transient according to ANSI/IEEE C37.90.1) Linearity ±0.01% Span NMR 120 dB per decade above 10kHz Accuracy ±0.03% Span Input protection 240 Vrms max. Output protection Continuous short to ground Connectors: Four insulated DB9 input connectors on a 0.5U panel ±0.01% Span SC4-BRH-10V2mV ±0.01% Span ±0.01% Span ±0.03% Span ±0.03% Span ±0.03% Span 240 Vrms max. 240 Vrms max. 240 Vrms max. Continuous short to ground Continuous short to ground Continuous short to ground D300-16 typical applications VEHICLE / CAN / GPS testing BURN-IN and LIFE-CYCLE testing SHOCK RESPONSE SPECTRUM testing GENERAL PURPOSE testing The 16 inputs can be configured with every kind of sensor: strain, accel, voltage, current, temperature, and more. Add two CAN BUS interfaces to add vehicle data, and a GPS sensor to record vehicle speed, position, heading, and other parameters. The D300-16 is versatile enough to handle just about any data acquisition application, including factory burn-inm HALT and HASS testing, of satellite components, vehicle parts, motors and turbines, manufacturing equipment, and more. With its 16 dynamic IEPE inputs, the D30016 makes a great SRS instrument. Configure your inputs for charge, IEPE, or strain gages, voltages, and more. Get the UP-ORION-16-24 upgrade, the DS-OPT-SRS software option, and your sensors. Any basic data acquisition application where you need a small footprint self contained data acquisition instrument with great dynamic specifications (24-bit, 200 kS/s/ch, anti-aliasing)... at a great price point! Dewetron PRODUCT SELECTION GUIDE 21 D300 expansion guide 32-channel ORION card in D300-16 mainframe Expansion via analog cable A very popular way of expanding the analog inputs is to upgrade the ORION card from 16 to 32 dynamic channels, then connect external signal conditioning amplifiers via an analog cable. Simply upgrade the D300-16 to have 32 A/D channels inside via either the UP-ORION-16-22-32 (22-bit @ 100 kS/s/ch) or the UP-ORION-1616-32 option (16-bit @ 100 kS/s/ch), then add an external 16 channel conditioning chassis and cable. Choose from MDAQ or DAQ / HSI series plug-in conditioners. AN A LO PO G SIGNALS WE PP R SU LY AC (optional DC) power supply DEWE-31-16 or DEWE-30-16 expansion chassis Expansion chassis DEWE-30-16 DEWE-31-16 Amplifier slots 16 -- MDAQ channels -- 8 or 16 A/D converter (Connects to the A/D card in the main system - there is no A/D converter inside any DEWE-30 or DEWE-31 chassis) Power supply (standard) 120/230 VAC 50/60 Hz DC from the mainframe or via AC/DC adapter Dimensions (WxDxH) 435 x 133 x 245 mm 17.1 x 5.2 x 9.6 in. 208 x 95 x 108 mm 8.2 x 3.7 x 4.3 in Weight 4 kg (9 lbs) 1.6 kg (3.5 lbs) Expansion via PCI bridge The PCI expansion is an alternative especially if high channel count is needed. The best mainframe to use is the D3PC computer chassis, which has no inputs of its own, but it will contain the PCI bridge card and run the whole system. The DEWE-50, DEWE-51 and DEWE-52 ADC racks can be connected by a 1m PCI cables. ORION series cards are installed inside the DEWE-5x unit and you simply have to select the suitable signal amplifiers for your needs. AC (optional DC) power supply D3PC with PCI PCI H OST bridge card inside In this way, the D3PC can serve as the host of a system with dozens, hundreds, or even more than 1000 dynamic input channels! SY N C Important notice: Each DEWE-50/51/52 chassis must be equipped with ORION-SYNC option. DEWE-52-PCI-3216 Expansion chassis DEWE-50-PCI-32 DEWE-50-PCI-64 DEWE-51-PCI-32 DEWE-51-PCI-128 DEWE-52-PCI-3216 Amplifier slots 32 64 -- -- 16 MDAQ channels -- -- Up to 64 Up to 128 Up to 32 ORION card slots 3 7 7 13 7 Power supply (standard) 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz 120/230 VAC 50/60 Hz Dimensions (WxDxH) 435 x 287 x 223 mm 17.1 x 11.3 x 8.8 in. 408 x 287 x 410 mm 16.1 x 11.3 x 16.1 in. 435 x 287 x 178 mm 17.1 x 11.3 x 7.0 in. 408 x 287 x 267 mm 16.1 x 11.3 x 10.5 in 435 x 287 x 223 mm 17.1 x 11.3 x 8.8 in. Weight 10 kg (22 lbs) 15 kg (33 lbs) 6 kg (13 lbs) 9 kg (20 lbs) 9 kg (20 lbs) 22 Dewetron PRODUCT SELECTION GUIDE Expansion via Ethernet The NET expansion is a fantastic way to combine two or more DEWE instruments to one multichannel system. Each instrument must have installed hardware option ORIONSYNC and software option DS-OPT-NET. Synchronization of all units is required too. There are two ways of synchronization: First is a simple cable connection for distances up to 200 m, second one is GPS- or DEWE-CLOCK which is useful for long distances when a cable connection is not possible. DS-OPTNET software offers full remote setup, online data transfer up to the limit of the network connection and offline data transfer between the instruments. User tip: The NET expansion also distributes the data processing load among multiple computers, each of which can store data at full speed. Specifications Specification D300 series Direct Voltage / IEPE inputs: D3PC-4: 4 channels D3PC-8: 8 channels MDAQ-SUB positions D300-16: 2 positions (16 channels) SC4 positions D300-16: 4 positions (16 channels) Main system Total PCI slots 1 x half-length PCI slots Hard disk 500 GB standard removable drive (optional solid state drive) Data throughput to disk 50 MB/s typical; faster rates available with the additional of an internal RAID controller and/or additional drives Power supply 9~29 VDC. Includes external AC/DC power adapter for operating the system from 120/240 VAC 50/60 Hz. Processor Intel Core2Duo 2.0 GHz CPU, on a standard industrial grade MiniITX mainboard RAM 2 GB (expandable to 4 GB) Computer interfaces: 2 x Gb ethernet; 4 x USB 2.0; 1 x RS232 serial (DB9 connector) Operating system Microsoft Windows7 32-bit included (64-bit available Q4 2012) Dimensions (W x D x H) (without bumpers) D3PC: 8.5 x 4.75 x 10.78 (216 x 121 x 274 mm) D300: 14.5 x 4.75 x 10.78 (368 x 121 x 274 mm) Weight D3PC models: 4 kg typical (~9 lbs) D300-16 models: 5.5 kg typical (~12 lbs) Environmental specifications Operating temperature -20 to 50°C (0 to 45°C with batteries installed) (storage temp -20 to 60C) Humdity 10 to 80% non-condensing, 5 to 95% relative humidity Vibration MIL-STD-810F, EN 60068-2-6, EN 60721-3-2 class 2M2 Shock MIL-STD-810F, EN 60068-2-27 Data acquisition specifications D3PC-4 model: Includes ORION-0424-200 A/D card (IEPE signal conditioning included) 4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V 4 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support 24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters Single-ended or differential inputs, software selectable AC (0.15 or 3.4 Hz) or DC coupled One synchronous advanced counter/encoder with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, DB9 connector External trigger input D3PC-8 model: Includes ORION-0824-200 A/D card (IEPE signal conditioning included) 4 different input ranges: ±0.1V, ±0.5V, ±2V, ±10V 8 BNC connectors for analog voltage or ICP (4 / 8 mA) inputs, TEDS support 24-bit resolution, simultaneous sampling, 204.8 kS/s per channel, antialiasing filters Single-ended or differential inputs, software selectable AC (0.15 or 3.4 Hz) or DC coupled Two synchronous advanced counters/encoders with programmable threshold levels (0 ~ 40 V), input voltage range -35 ~ 60 V, LEMO connectors 8 synchronous TTL digital I/Os and one external trigger input, DB37 D300-16 model: Includes ORION-1616-100 A/D card (requires signal conditioning) 100 kS/s/ch simultaneous sampling, 16-bit resolution (ORION-1616-100) Please order your choice of either 4 x SC4 conditioners, or MDAQ PANEL and SUB modules to complete this system. Upgrades to faster cards, and higher resolution cards available D300-16 A/D card upgrades: UP-ORION-16-22: upgrade to 22-bit with 102.4 kS/s/ch and anti-aliasing UP-ORION-16-22-32: upgrade to 22-bit with 102.4 kS/s/ch and from 16 to 32 channels UP-ORION-16-24: upgrade to 22-bit with 204.8 kS/s/ch and anti-aliasing UP-ORION-100-500: upgrade to 16-bit with 500 kS/s/ch UP-ORION-100-1000: upgrade to 16-bit with 1000 kS/s/ch UP-ORION-1616-3216: upgrade from 16 channels to 32 channels (100 kS/s/ch maximum sample rate @ 16-bit resolution) Data acquisition software: DS-7-SE is included as standard Software upgrades available: To DS-7-PROF, DS-7-DSA, and a variety of OPTIONS and PLUGINS D300-16 EPAD interface: Standard LEMO 4-pin connector. EPAD2 modules are daisy-chainable D3PC-8 D300-16 SYNC ETHERNE T 0.000 ms D300-16 GPS-CLOCK SYNC External channel expansion Low-speed channel expansion: Up to 16 EPAD2 modules can be connected to the EPAD connector, adding up to 128 channels of low-speed thermocouple, voltage, RTD, and current inputs, in blocks of eight channels Expansion via analog cable: D300-16 only - first upgrade the internal A/D card to have 32 channels: UP-ORION-1616-3216 upgrades the std card from 16 to 32 channels UP-ORION-16-22-32 upgrades the std card from 16 to 32 channels, and from 16-bit to 22-bit resolution with anti-aliasing filtering D300-16 only - then add an external 16 channel chassis of conditioning (see optional expansion chassis on this page) Expansion via PCI bridge: Up to 256 total dynamic analog input channels (with PCI bridge card installed inside the D3PC, and external DEWE-50/51 chassis connected. Expansion via ethernet: Up to 2000 total dynamic analog input channels (with SYNC option for local connections, or IRIG/GPS sync for remote connections, and multiple remote DEWE systems synchronized via DS-OPT-NET software option. GPS-CLOCK D3PC-8 SYNC ETHER NET Dewetron PRODUCT SELECTION GUIDE 23
advertisement
Key Features
- Economical and highly configurable system
- Full power DEWE computer inside
- 500 GB removable HDD
- VGA connector with XGA resolution display
- Includes keyboard and mouse
- Wide range DC power input
- Ruggedized construction, MIL-STD, CE MARK, and more
- Small footprint D3PC available also as pure computer
- Made in USA
- Full year warranty
Frequently Answers and Questions
How many channels can the D300-16 be configured with?
The D300-16 can be configured with up to 16 isolated SC4 series basic signal conditioners or 16 MDAQ differential signal conditioning channels.
What are the standard features of the D300 series?
The D300 series includes a full power DEWE computer inside, 500 GB removable HDD, a VGA connector with XGA resolution display, a keyboard and mouse, a wide range DC power input, ruggedized construction, a small footprint D3PC available also as a pure computer, and comes with a full year warranty.
Which MDAQ-SUB modules are compatible with the D300-16?
The D300-16 is compatible with any two of the MDAQ-SUB 8-channel conditioners, which can be installed on the front panel, with BNC or DSUB connectors.