RAB Lighting CLED2X18NW Architectural Instructions
Below you will find brief information for LED fixture CLED 2X10, LED fixture CLED 2X13, LED fixture CLED 2X18, LED fixture CLED 2X20, LED fixture CLED 2X26. These LED fixtures are designed for installation on a recessed junction box and are compatible with a variety of mounting surfaces. They are also dimmable and can be operated at different voltages.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
CLED2X10
CLED2X13
CLED2X18
CLED2X20
CLED2X26
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE .
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CLED TO MOUNTING SURFACE
Mount the CLED to a recessed Junction Box as follows:
1. Mount the Adaptor Plate to mounting surface with appropriate hardware.
2. Attach Tether to fixture and wire the fixture as shown in the wiring section.
3. Align the Canopy on fixture to Adaptor Plate and tighten
(2) Side Screws through the Canopy to the Adaptor Plate.
Be sure the Gasket is in place.
4. Use weatherproof silicone sealant between the Adaptor
Plate and mounting surface.
Adaptor Plate
Gasket
CLED TO JUNCTION BOX
Mount the CLED Junction Box (sold separately) as follows:
1. Mount the Junction Box to ceiling with provided hardware. Be sure the Ceiling Gasket is in place.
2. Attach Adaptor Plate with the screws provided.
3. Attach Tether to fixture . Feed wires through the conduit entry and wire the fixture as shown in the wiring section.
4. Align the Canopy on fixture to Adaptor Plate and tighten
(2) Side Screws through the Canopy to the Adaptor Plate.
Be sure the Gasket is in place.
5. Use weatherproof silicone sealant between the Adaptor
Plate and Junction Box, Junction Box and ceiling and around conduit entries of the Junction Box.
Ceiling
Gasket
CLEDBB
Junction
Box
Adaptor Plate
Canopy
Side Screws
Gasket
Side Screws
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: [email protected]
WIRING
Universal voltage driver permits operation at 50Hz or 60Hz and the following voltages:
CLED 2X10: 120 Volts - 240 Volts
CLED 2X13: 120 Volts - 277 Volts
CLED 2X18: 120 Volts - 277 Volts
CLED 2X20: 120 Volts - 277 Volts
CLED 2X26: 120 Volts - 277 Volts
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the bare copper Ground wire from fixture to supply ground.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru
277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. For 0-10V Dimming, follow the wiring directions as in fig. 2.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead. Do NOT connect.
Fig. 1
Fig. 2
ACCESSORIES
GDWPL1P Polyshield for 10W & 13W
Order 2 per CLED or “/P” for installed
GDWPL2P Polyshield for 20W
Order 2 per CLED or “/P” for installed
No wire guard is available at this time
CLEDBB CLED back box
Available in Bronze and White
OPTIONS
Suffix “Y” = Warm 3000K LED
Suffix “N” = Neutral 4000K LED
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2 . Do not open fixture to clean the LED. Do not touch
the LED.
TROUBLESHOOTING
1. Check that the line voltage at fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly.
US: pat. D608,040; D615,689, CN: ZL201030129125.7,
ZL201030129137.X, MX: 32130, 32491, TW: pat. D139540, D139372,
CA: D RAB Lighting, Inc.
©2014 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
CLED-IN-0715
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000 rabweb.com
Visit our website for product info email
Answered promptly [email protected]
advertisement
Key Features
- Recessed Junction Box Installation
- Dimmable
- Universal Voltage
- Weatherproof
- Easy to Install
- Multiple Mounting Options