RAB Lighting CLED2X18NW Architectural Instructions

RAB Lighting CLED2X18NW Architectural Instructions

Below you will find brief information for LED fixture CLED 2X10, LED fixture CLED 2X13, LED fixture CLED 2X18, LED fixture CLED 2X20, LED fixture CLED 2X26. These LED fixtures are designed for installation on a recessed junction box and are compatible with a variety of mounting surfaces. They are also dimmable and can be operated at different voltages.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

RAB Lighting LED Fixture CLED Installation Instructions | Manualzz

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.

Call the Marketing Department at 888-RAB-1000 or email: [email protected]

CLED2X10

CLED2X13

CLED2X18

CLED2X20

CLED2X26

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE .

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A

PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

CLED TO MOUNTING SURFACE

Mount the CLED to a recessed Junction Box as follows:

1. Mount the Adaptor Plate to mounting surface with appropriate hardware.

2. Attach Tether to fixture and wire the fixture as shown in the wiring section.

3. Align the Canopy on fixture to Adaptor Plate and tighten

(2) Side Screws through the Canopy to the Adaptor Plate.

Be sure the Gasket is in place.

4. Use weatherproof silicone sealant between the Adaptor

Plate and mounting surface.

Adaptor Plate

Gasket

CLED TO JUNCTION BOX

Mount the CLED Junction Box (sold separately) as follows:

1. Mount the Junction Box to ceiling with provided hardware. Be sure the Ceiling Gasket is in place.

2. Attach Adaptor Plate with the screws provided.

3. Attach Tether to fixture . Feed wires through the conduit entry and wire the fixture as shown in the wiring section.

4. Align the Canopy on fixture to Adaptor Plate and tighten

(2) Side Screws through the Canopy to the Adaptor Plate.

Be sure the Gasket is in place.

5. Use weatherproof silicone sealant between the Adaptor

Plate and Junction Box, Junction Box and ceiling and around conduit entries of the Junction Box.

Ceiling

Gasket

CLEDBB

Junction

Box

Adaptor Plate

Canopy

Side Screws

Gasket

Side Screws

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.

Call the Marketing Department at 888-RAB-1000 or email: [email protected]

WIRING

Universal voltage driver permits operation at 50Hz or 60Hz and the following voltages:

CLED 2X10: 120 Volts - 240 Volts

CLED 2X13: 120 Volts - 277 Volts

CLED 2X18: 120 Volts - 277 Volts

CLED 2X20: 120 Volts - 277 Volts

CLED 2X26: 120 Volts - 277 Volts

1. Connect the black fixture lead to the (+) LINE supply lead.

2. Connect the white fixture lead to the (-) COMMON supply lead.

3. Connect the bare copper Ground wire from fixture to supply ground.

0-10V DIMMABLE WIRING

Universal voltage driver permits operation at 120V thru

277V, 50 or 60 Hz. 0-10V control wires must be rated for 300V minimum. For 0-10V Dimming, follow the wiring directions as in fig. 2.

1. Connect the black fixture lead to the (+) LINE supply lead.

2. Connect the white fixture lead to the (-) COMMON supply lead.

3. Connect the GROUND wire from fixture to supply ground.

Do NOT connect the GROUND of the dimming fixture to the output.

4. Connect the purple fixture lead to the (V+) DIM lead.

5. Connect the gray fixture lead to the (V-) DIM lead.

6. Cap the yellow fixture lead. Do NOT connect.

Fig. 1

Fig. 2

ACCESSORIES

GDWPL1P Polyshield for 10W & 13W

Order 2 per CLED or “/P” for installed

GDWPL2P Polyshield for 20W

Order 2 per CLED or “/P” for installed

No wire guard is available at this time

CLEDBB CLED back box

Available in Bronze and White

OPTIONS

Suffix “Y” = Warm 3000K LED

Suffix “N” = Neutral 4000K LED

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

1. Clean glass lens with non-abrasive glass cleaning

solution.

2 . Do not open fixture to clean the LED. Do not touch

the LED.

TROUBLESHOOTING

1. Check that the line voltage at fixture is correct. Refer to wiring directions.

2. Be sure the fixture is grounded properly.

US: pat. D608,040; D615,689, CN: ZL201030129125.7,

ZL201030129137.X, MX: 32130, 32491, TW: pat. D139540, D139372,

CA: D RAB Lighting, Inc.

©2014 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

CLED-IN-0715

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Easy Installation & Product Help

Tech Help Line

Call our experts 888 RAB-1000 rabweb.com

Visit our website for product info email

Answered promptly [email protected]

advertisement

Key Features

  • Recessed Junction Box Installation
  • Dimmable
  • Universal Voltage
  • Weatherproof
  • Easy to Install
  • Multiple Mounting Options

Frequently Answers and Questions

What voltage does this LED fixture operate at?
The fixture can be operated at 120V thru 277V, 50 or 60 Hz.
What type of junction box is required for this fixture?
A recessed junction box is required.
Is this fixture dimmable?
Yes, the fixture is dimmable. It can be controlled with an 0-10V dimming system.
How do I ground this fixture properly?
Connect the bare copper Ground wire from fixture to supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
What are the dimensions of this fixture?
The dimensions are not specified, but you can find them on RAB Lighting's website.
How do I clean this fixture?
You can clean the glass lens with non-abrasive glass cleaning solution.
What type of sealant should I use?
Use weatherproof silicone sealant.

Related manuals

Download PDF

advertisement