D2F-01-D3 даташит

D2F-01-D3 даташит
Snap Action Switch
D2F
Subminiature Snap Action Switch
• Switches 3 A loads (general-purpose), 1 A loads
(low force general-purpose) and 0.1 A loads(microvoltage/
microcurrent)
• Long life span assured by high-precision dual spring
reverse-action mechanism
• Flux penetration prevented by using an insert terminal and
allowing a height difference at the case bottom
• Ideal for a wide range of applications including appliances,
office equipment, audio and communications equipment
• RoHS Compliant
Ordering Information
Actuator
Contact
type
Model
Contact Model
OF
Terminal type
PCB
Selfsupporting
Solder
Compact
Solder
Right-angle
D2F-01F
D2F-01F-T
D2F-01F-D3
D2F-01F-D
D2F-01F-A
D2F-01F-A1
D2F-01
D2F-01-T
D2F-01-D3
D2F-01-D
D2F-01-A
D2F-01-A1
Low force 75 g
D2F-F
D2F-F-T
D2F-F-D3
D2F-F-D
D2F-F-A
D2F-F-A1
Standard
D2F
D2F-T
D2F-D3
D2F-D
D2F-A
D2F-A1
D2F-01FL
D2F-01FL-T
D2F-01FL-D3 D2F-01FL-D
D2F-01FL-A
D2F-01FL-A1
D2F-01L
D2F-01L-T
D2F-01L-D3
D2F-01L-A
D2F-01L-A1
Pin plunger Microvoltage/ Low force 75 g
current
Standard 150 g
Generalpurpose
150 g
Hinge lever Microvoltage/ Low force 25 g
current
Standard 80 g
Generalpurpose
Simulated
roller lever
D2F-01L-D
Left-angle
Low force 25 g
D2F-FL
D2F-FL-T
D2F-FL-D3
D2F-FL-D
D2F-FL-A
D2F-FL-A1
Standard
D2F-L
D2F-L-T
D2F-L-D3
D2F-L-D
D2F-L-A
D2F-L-A1
D2F-01FL3-D3 D2F-01FL3-D D2F-01FL3-A D2F-01FL3-A1
80 g
Microvoltage/ Low force 40 g
current
Standard 80 g
D2F-01FL3
D2F-01FL3-T
D2F-01L3
D2F-01L3-T
D2F-01L3-D3
D2F-01L3-D
D2F-01L3-A
D2F-01L3-A1
Generalpurpose
Low force 40 g
D2F-FL3
D2F-FL3-T
D2F-FL3-D3
D2F-FL3-D
D2F-FL3-A
D2F-FL3-A1
Standard
D2F-L3
D2F-L3-T
D2F-L3-D3
D2F-L3-D
D2F-L3-A
D2F-L3-A1
D2F-01FL2
D2F-01FL2-T
D2F-01FL2-D3 D2F-01FL2-D D2F-01FL2-A D2F-01FL2-A1
80 g
Roller lever Microvoltage/ Low force 40 g
current
Standard 80 g
Generalpurpose
D2F-01L2
D2F-01L2-T
D2F-01L2-D3
D2F-01L2-D
D2F-01L2-A
D2F-01L2-A1
Low force 40 g
D2F-FL2
D2F-FL2-T
D2F-FL2-D3
D2F-FL2-D
D2F-FL2-A
D2F-FL2-A1
Standard
D2F-L2
D2F-L2-T
D2F-L2-D3
D2F-L2-D
D2F-L2-A
D2F-L2-A1
80 g
Model Number Legend
D2F1 2 3 4
1.
2.
Ratings
None: General loads
01:
Micro loads (0.1 A at 30 VDC)
3.
Actuator
4.
None: Pin plunger
L:
Hinge lever
L2:
Hinge roller lever
L3:
Simulated roller lever
Maximum Operating Force
None: 1.47 N {150 gf}
F:
0.74 N {75 gf}
Note: These OF values are for the pin plunger models.
Terminals
None: PCB terminals/straight terminals
-T:
Self-clinching PCB terminals
-A:
Right-angled PCB terminals
-A1: Left-angled PCB terminals
-D3: Solder terminals
-D:
Compact solder terminals
Snap Action Switch
D2F
31
Specifications
■ Characteristics
Operating speed
1 to 500 mm/second (pin plunger models)
Operating frequency
Mechanical: 200 operations per minute max.
Electrical: 30 operations per minute max.
Contact resistance
General Purpose: 30 mΩ max. (Standard force versions)
50 mΩ max. (Low force versions)
Microload:
100 mΩ max.
Insulation resistance
100 MΩ min. at 500 VDC
Dielectric strength (See note 2)
600 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal parts
Vibration resistance (See note 3)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (See note 3)
Destruction: 1,000 m/s2 (approx. 100G) max.
Malfunction: 300 m/s2 (approx. 30 g min.) max.
Degree of protection
IEC IP40
Degree of protection against
electric shock
Class I
Proof tracking index (PTI)
175
Ambient operating temperature
-25° to 65°C (at 60% RH) with no icing
Ambient operating Humidity
85% max. (for 5° to 35°C)
Service life
Mechanical: 1 million operations min. at 60 operations/minute.
(Consult Omron for test conditions) Electrical: 30,000 operations min. at 30 operations/minute.
Weight
Approx. 0.5 g (pin plunger models)
Note: 1. Data shown are of initial value.
2. The dielectric strength shown in the table indicates a value for models with a separator.
3. For pin plunger models, the values are measured at the free position and total travel position. For the lever models, they are measured
at the total travel position.
■ Ratings
Rated Voltage
Resistive load
Microvoltage/current (D2F-01 models)
General-purpose (D2F models)
Low force
Standard
Low force
Standard
125 VAC
—
—
1A
3A
30 VDC
0.1 A
0.1 A
0.5 A
2A
Note: 1. When using an inductive load or motor load, consult OMRON.
2. The ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
■ Approvals
■ Contact Specifications
Contact Omron to obtain standards approvals on specific models.
UL Recognized, CSA Certified
D2F
D2F-01
Rated voltage
Standard
Force
Low Force
125 VAC
3A
1A
---
30 VDC
2A
0.5 A
0.1 A
Note: The rated values approved by each of the safety standards
(e.g.UL,CSA) may be different from the performance characteristics individually defined in this catalog.
Item
D2F
Specification
Crossbar
D2F-01
Material
Silver alloy
Gap
(Standard value)
0.25 mm
Gold alloy
Minimum Applicable Load
(See note)
100 mA at 5 VDC 1 mA at 5VDC
Note: Minimum applicable loads are indicated by N standard
reference values. This value represents the failure rate at a
60% (λ60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6/operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
32
Snap Action Switch
D2F
Engineering Data
■ Mechanical Service Life
■ Electrical Service Life
Number of operations (x10 3)
D2F
Ambient temperature: 20°±2°C
Ambient humidity:
65±5% max.
Without load
Operating frequency: 60 operations/min
7,000
5,000
3,000
1,000
700
500
300
100
Number of operations (x10 3)
D2F, D2F-01
10,000
Ambient temperature: 20°±2°C
Ambient humidity:
65±5% max.
Without load
Operating frequency: 30 operations/min
300
100
125 VAC
50
30
30 VDC
20
10
0
Overtravel (mm)
Rated operating current (A)
Note: Values are for pin plunger actuator type.
■ Mounting
■ PCB Layout (reference)
All switches may be panel mounted using M2 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.08 to 0.1 N·m.
2.54
Two , 2-dia. mounting holes
5.8 ± 0.15
2.54
6.5 ± 0.15
Use of molded components is recommended for mounting purposes
5.08 ± 0.1
Three,
1.2 dia. holes
12.8 ± 0.15
■ Structure
Contact Form (SPDT)
Snap Action Switch
D2F
33
Dimensions
■ Terminals
Note: Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
PCB terminals
Self-supporting terminals
D2F
D2F-T
3.15
6.5±0.1
1.5
1.5
3.5
3.4
3.15
0.4
0.9
5.08
5.08
12.8±0.15
6.5±0.1
1.6±0.15
0.9
5.8±0.15
1.25±0.15
5.8±0.15
Solder terminals
Compact solder terminals
D2F-D3
D2F-D
1.5
1.5 2.4
3.5
2
0.5
3.15
6.5±0.1
5.08
5.08
12.8±0.15
1.2
2.2
3.15
0.4
6.5±0.1
5.08
5.08
12.8±0.15
Three, 0.8-dia. holes
5.8±0.15
0.4
1.6
5.8±0.15
Right-angle PCB terminals
Left-angle PCB terminals
D2F-A
D2F-A1
1.5
1.5
2.6±0.2
3.15
6.5±0.1
5.08
5.08
12.8±0.15
0.9
0.4
5.8±0.15
3.1±0.2
2.6±0.2
3.15
6.5±0.1
5.08
5.08
12.8±0.15
(Top view)
Left-angled terminal
Snap Action Switch
0.9
D2F
Right-angled terminal
5.8±0.15
0.4
3.1±0.2
(Top view)
Note: Angled terminal directions are shown below.
34
1.5
0.4±0.05
5.08
5.08
12.8±0.15
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Omitted dimensions are the same as pin plunger type.
3. The following illustrations and dimensions are for models with PCB terminals. Refer to “Terminals” for models with self-supporting, solder
and right / left angle terminal specifics.
4. The operating characteristics are for operation in the A direction( )
Pin Plunger Models
D2FD2F-01D2F-FD2F-01F-
12.7
1.2
+0.12
2.2 0
5.2
A
dia.
5
2 +0.12
0
[email protected]
[email protected]
OF max.
150 g
75 g
RF min.
20 g
5g
OP
PT max.
0.5 mm
0.5 mm
1.5
OT min.
0.25 mm
0.25 mm
3.5
MD max.
0.12 mm
0.12 mm
5.5 ± 0.3 mm
5.5 ± 0.3 mm
—
—
[email protected]
[email protected]
[email protected]
[email protected]
OF max.
80 g
25 g
RF min.
5g
2g
PT max.
—
—
OT min.
0.55 mm
0.55 mm
0.4
0.9
6.5±0.1
3.15
[email protected]
[email protected]
5.7
2.9
PT +0.12
20
dia. holes
Characteristics
OP
FP max.
5.08
5.08
12.8±0.15
5.8±0.15
Hinge Lever Models
D2F-LD2F-01LD2F-FLD2F-01FL-
12.8
Characteristics
(10.8)
t = 0.3 (see note)
3
A
FP
OP
MD max.
0.5 mm
0.5 mm
6.8 ± 1.5 mm
6.8 ± 1.5 mm
10 mm
10 mm
[email protected]
[email protected]
[email protected]
[email protected]
OF max.
80 g
40 g
RF min.
5g
2g
PT max.
—
—
OT min.
0.5 mm
0.5 mm
OP
FP max.
Note:
Stainless-steel lever
Simulated Roller Lever Models
D2F-L3D2F-01L3D2F-FL3D2F-01FL3-
Characteristics
12.7
(7.5)
A
t = 0.3 (see note)
2.1
10
3
1.3R
OP
FP
MD max.
0.45 mm
0.45 mm
8.5 ± 1.2 mm
8.5 ± 1.2 mm
13 mm
13 mm
[email protected]
[email protected]
[email protected]
[email protected]
OF max.
80 g
40 g
RF min.
5g
2g
PT max.
—
—
OT min.
0.55 mm
0.55 mm
OP
FP max.
Note:
Hinge Roller Lever Models
D2F-L2D2F-01L2D2F-FL2D2F-01FL2-
12.8
Stainless-steel lever
4
(10)
A 4.8 dia. × 2.8 (Resin roller)
(4.6)
t = 0.3
(see
note)
4
OP FP
Characteristics
MD max.
OP
FP max.
Note:
0.5 mm
0.5 mm
13 ± 2.0 mm
13 ± 2.0 mm
16.5 mm
16.5 mm
Stainless-steel lever
Snap Action Switch
D2F
35
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
■ Cautions
Mounting
Terminal Connection
Turn OFF the power supply before mounting or removing the switch,
wiring the switch, or performing maintenance or inspection. Failure to
do so may result in electric shock or burning.
When soldering a lead wire to the terminal, first insert the lead wire
conductor into the terminal hole and then perform soldering.
Mount the switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the switch, resulting in faulty operation or
breakage of the housing.
Make sure that the capacity of the soldering iron is 30 W maximum
and that the temperature of the soldering tip is approximately 300 °C.
(350 °C maximum.) Complete soldering within 3 s. After soldering,
do not apply external force to the soldered area for about 1 minute.
Allow sufficient insulation distance between terminals, terminal
traces and between terminals and ground.
Using a switch with improper soldering may result in abnormal heating, possibly resulting in a burn.
Operating Stroke Setting
Applying the soldering iron for more than 3 s or using an iron that is
rated for more than 30 W may deteriorate the switch characteristics.
Take particular care in setting the operating stroke for the pin plunger
models. Make sure that the operating stroke is 70% to 100% of the
rated OT distance. Do not operate the actuator exceeding the OT
distance, otherwise the service life of the switch maybe decreased.
When soldering the lead wire to the PCB terminal, pay careful
attention so that the flux and solder liquid level does not exceed the
PCB level.
Using Microloads
Voltage (V)
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for microloads and that operate in the following range;
Operating range
for micro load
models D2F-01
Operating
range for
general-load
models
D2F
Inoperable
range
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, it may increase contact
wear and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
36
Snap Action Switch
D2F
MEMO
Snap Action Switch
D2F
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X303-E-1
11/10
Snap Action Switch
D2F
Specifications subject to change without notice
Printed in USA
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement