GYRO-TECH 300/400/500 SWING CONTROL Swing Control Installation guide

GYRO-TECH 300/400/500 SWING CONTROL Swing Control Installation guide

Below you will find brief information for Swing Control 300/400/500 GYRO-TECH SWING CONTROL. The 300/400/500 GYRO-TECH SWING CONTROL is a Swing Control, so it includes functions that allow for the safe operation of the door after the door is powered up. This is necessary for the proper operation of the door, as the door needs to be powered up before the door can be opened.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

GYRO-TECH SWING CONTROL 300/400/500 Installation Guide | Manualzz
BLUE
BROWN
GREEN
BLACK
WHITE
RED
GRAY
RED/ WHITE
PURPLE
LO21 DEFAULT DIP SWITCHES
RED
WHITE
BLACK/ WHITE
OFF
GREEN
BLUE
GREEN
BROWN
ORANGE
RED
(+)
BLACK
(-)
ON
DOOR MTD SENSOR
APPROACH SIDE
DOOR MTD SENSOR
SAFETY SIDE
EMPTY
1
GREEN
WHITE
BLACK
RED
WHITE
GREEN
INHIBIT GND 2
5
BLACK
4
6
RED
3
7
N.C.
COM
8
INHIBIT +
POWER
N.O.
POWER
1
INHIBIT GND 2
EMPTY
WHITE
GREEN
4
5
3
6
RED
BLACK
INHIBIT +
COM
8
7
N.C.
POWER
N.O.
POWER
EAGLE 1
Pin
A (+)
Pin
B (-)
HOLD OPEN
Y
LA
RE
OFF
ACTIVATION
RELAY
AUTO
SUPERSCAN QUICKDISCONNECT CABLE
(ATTACHED TO
GT INHIBIT HARNESS)
SAFETY(WHITE)
White
COMMON(RED)
Reactivation
OPERATOR
HARNESS
W/10 PIN
CONNECTOR
OPEN
CHECK
CLOSE
CHECK
RELAY HARNESS
PN (20.5155)
ACTIVATE(BLACK)
300/400/500
GYRO-TECH
SWING CONTROL
10 Pin
control
connector
STANDARD SAFE
BLACK
MOTOR/
OPERATOR
top view
Power
RED
24 V
TRANSFORMER
NOTES:
1.) SET CONTROL SLIDE SWITCH TO "STANDARD SAFE".
2.) ROUTE LO21 RED AND BLACK TO CONTROL ACTIVATION RELAY AS SHOWN.
ENSURE THE RED IS CONNECTED TO PIN "A" AND BLACK TO PIN "B".
3.) IF INSTALLING ON A PAIR OF OPERATORS PARALLEL 2ND GT RELAY HARNESS WIRES.
RED TO RED, BLACK TO BLACK, GREEN TO GREEN, WHITE TO WHITE.
4.) CAP OFF UNUSED LO21 WIRES.
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT
1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE ANY
PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE
THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX:
(412) 249-4101
EMAIL: www.beasensors.com
TITLE: GYROTECH 300,400 WITH
SUPPERSCAN RELAY HARNESS
SIZE:
B
DRAWN BY:
TUC
REV BY:
JED
PART NO:
SCALE:
DATE:
SHEET
NONE
26 MAR 2009
1 OF 1
80.0248.01

advertisement

Key Features

  • Safety (White)
  • Common (Red)
  • Activate (Black)
  • SuperScan Quick Disconnect Cable
  • GT Inhibit Harness
  • Operator Harness

Frequently Answers and Questions

How do I set the control slide switch?
Set the control slide switch to "STANDARD SAFE".
How do I route the LO21 red and black wires?
Route the LO21 red and black wires to control activation relay as shown, ensuring red is connected to pin "A" and black to pin "B".
What do I do if installing on a pair of operators?
When installing on a pair of operators, parallel the 2nd GT Relay Harness wires: Red to red, black to black, green to green, white to white.