Swegon PSM 130, PSM 165, PSM 200, PSM 260, PSM 310, PSM 380, PSM 480, PSM 690, PSM 920, PSM 1100 Pumping set module User Manual
Below you will find brief information for Pumping set module PSM 130, Pumping set module PSM 165, Pumping set module PSM 200, Pumping set module PSM 260, Pumping set module PSM 310, Pumping set module PSM 380, Pumping set module PSM 480, Pumping set module PSM 690, Pumping set module PSM 920, Pumping set module PSM 1100. These units are designed for circulating and storing water in heating or cooling hydraulic circuits. The manual provides detailed instructions on proper installation, operation, and maintenance.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
PSM Stazioni di pompaggio con pompe centrifughe e serbatoio d’accumulo Pumping set modules with centrifugal pumps and buffer tank indice Generalita’ Caratteristiche tecniche Accessori La serie Campo di applicazione Generalita’ Ispezione, trasporto e posizionamento Ispezione Sollevamento e trasporto Disimballaggio Posizionamento Installazione Spazi di installazione Raccomandazioni generali per i collegamenti idraulici Collegamenti elettrici Generalita’ Collegamenti elettrici dell’unità Consensi esterni Avviamento Controlli preliminari Messa in funzione Arresto del gruppo Limiti di funzionamento Manutenzione e controlli periodici Avvertenze Generalità Messa fuori servizio dell’unita’ Ricerca guasti Disegni di ingombro Schema circuito idraulico Dati tecnici Prevalenze utili 1476 1476 1476 1477 1477 1477 1478 1478 1479 1480 1481 1482 1484 1484 1485 1485 1486 1486 1486 1487 1488 1488 1488 1489 1489 1490 1494 1496 1497 GENERALITA' GENERAL DESCRIPTION CARATTERISTICHE TECNICHE TECHNICAL FEATURES 1476 Stazioni di pompaggio con pompe centrifughe, serbatoio di accumulo e vaso di espansione per impianti idraulici di raffreddamento e riscaldamento. Pumping set modules with centrifugal pumps, buffer tank and expansion vessel for cooling and heating hydraulic plants. Stazioni di pompaggio PSM Pumping set modules PSM STRUTTURA a telaio portante e pannellature asportabili, (esclusi i modelli 380-680-9201100 che sono forniti con griglie metalliche) è realizzata in lamiera zincata ulteriormente verniciata con polveri poliestere a 180 °C, che le conferiscono un’alta resistenza agli agenti atmosferici. Viteria in acciaio inox. UNIT FRAME Self supporting frame with removable panels (models 380-680-920-1100 excluded, as supplied with metallic grilles) made of galvanized steel protected with polyesthere powder painting baked enamel which allows the unit to be installed outdoor.Stainless steel screws and bolts. ELETTROPOMPE Due elettropompe centrifughe monoblocco con accoppiamento diretto motore-pompa tramite unico albero in acciaio al cromo. Corpo e girante in ghisa, tenuta meccanica, motore elettrico a 2 poli trifase con grado di protezione elettrica IP 54. Le due elettropompe disposte in parallelo,funzionano alternativamente. Disponibile a richiesta la versione con pompa singola. PUMPS Two cenrtifugal pumps directly coupled with the electric motor by extended chrome steel shaft,. Cast iron pump casing and impeller, mechanical seal, 2 pole three-phase motor, IP 54 protection. The two pumps are installed in parallel and one is stand-by. On request, the version with single pump is available. SERBATOIO Serbatoio in lamiera zincata con coibentazione in poliuretano espanso rivestito in PVC. STORAGE TANK Foamed poyurethan insulated storage tank, PVC coated. CIRCUITO IDRAULICO Circuito idraulico interno costituito da tubi in gomma flessibili o acciaio, raccorderia in acciaio, valvole di ritegno, saracinesche, valvole di sfiato, vaso di espansione. HYDRAULIC CIRCUIT Hydraulic circuit composed with flexible rubber tubes, steel pipe fittings, check valves, gate valves, vent valves and expansion vessel. QUADRO ELETTRICO Il quadro elettrico con grado protezione IP 55 comprende: - sezionatore generale - interruttori magnetotermici delle pompe - teleruttori delle pompe - selettore-interruttore di marcia delle pompe ELECTRIC SWITCH BOARD According to IP 55 it includes : ACCESSORI: ACCESSORIES: • Resistenza elettrica serbatoio • Resistenza elettrica antigelo per le pompe • Versione con pompa singola • Gruppo di caricamento automatico dell’acqua • Valvola di sicurezza • Manometri • Antivibranti in gomma od a molla • Alimentazione elettrica con differenti tensioni o frequenze • Predisposizione per funzionamento con fluidi a basse temperature (speciale tenuta meccanica delle pompe). • • • • • • • • - main switch pump circuit breakers pump contactors pump selector switch Tank electric heater No frost electric heater for pumps Single pump version Automatic water filling kit Safety valve Water pressure gauges Rubber or spring antivibration mounts Electric supply with different voltages or frequencies • Provision for operation with low temperature fluids (pump’ special mechanical seal) LA SERIE THE SERIES La serie di stazioni di pompaggio PSM è disponibile in varie grandezze con portate e prevalenze che variano da modello a modello (si vedano le tabelle dei dati tecnici). Pumping set module PSM series is available in various sizes with water flow and available static pressure varyng for each model (see technical data sheets). CAMPO DI APPLICAZIONE APPLICATION FIELD Queste unità sono destinate alla circolazione ed all’accumulo di acqua nei circuiti idraulici di riscaldamento e raffreddamento. Il loro utilizzo è raccomandato entro i limiti di funzionamento riportati nel capitolo 5 di questo manuale. These units have been designed for circulating and storing water in heating or cooling hydraulic circuits. Their recommended operation range is reported in chapter 5 of this manual. 1. GENERALITA’ 1. GENERALITY - All’atto dell’installazione o quando si debba intervenire sull’unità, è necessario attenersi scrupolosamente alle norme riportate su questo manuale, osservare le indicazioni a bordo unità e comunque applicare tutte le precauzioni del caso. - When installing or servicing the unit, it is necessary to strictly follow the recommendations reported on this manual, to conform to all the specifications of the labels on the unit, and to take any possible precautions of the case. - Le pressioni presenti nel circuito idraulico ed i componenti elettrici presenti possono creare situazioni rischiose durante gli interventi di installazione e manutenzione. - Pressure in the hydraulic circuit and electrical equipment present in the unit can be hazardous when installing or servicing the unit. Qualsiasi intervento sull’unità quindi deve essere effettuato da personale qualificato. Therefore every action on the unit must be done by trained people only. - Il mancato rispetto delle norme riportate in questo manuale e qualsiasi modifica nell’unità non preventivamente autorizzata, provocano l’immediato decadimento della garanzia. - Not observing the recommendations reported on this manual, and every modification to the unit done without explicit previous authorisation, will cause the immediate termination of the warranty. Att.ne: Prima di effettuare qualsiasi intervento sull’unità, assicurarsi di aver tolto l’alimentazione elettrica. Attention: before every operation of servicing on the unit, be sure that the electric supply is disconnected. 1477 2. ISPEZIONE, TRASPORTO, POSIZIONAMENTO 2. INSPECTION, TRANSPORT, SITE HANDLING 2.1 ISPEZIONE 2.1 INSPECTION All’atto del ricevimento dell’unità, verificarne l’integrità: la macchina ha lasciato la fabbrica in perfetto stato; eventuali danni dovranno essere immediatamente contestati al trasportatore ed annotati sul Foglio di Consegna prima di controfirmarlo. La nostra Azienda dovrà essere messa al corrente entro 8 giorni sull’entità del danno. Il Cliente deve compilare un rapporto scritto concernente ogni eventuale danno rilevante. After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any eventual damage must be questioned to the carrier and recorded on the Delivery Note before it is signed. Our Company must be informed, within 8 days, of the extent of the damage. The Customer should prepare a written statement of any severe damage. 2.2 SOLLEVAMENTO E TRASPORTO 2.2 LIFTING AND SITE HANDLING Durante lo scarico ed il posizionamento dell’unità, va posta la massima cura nell’evitare manovre brusche o violente. I trasporti interni dovranno essere eseguiti con cura e delicatamente, evitando di usare come punti di forza i componenti della macchina. L’unità va sollevata utilizzando tubi in acciaio infilati negli occhielli contraddistinti da apposita targatura (targhette gialle a forma di freccia). Il modulo va sollevato imbracandolo come indicato nelle figure riportate di seguito: utilizzare corde o cinghie abbastanza lunghe e barre distanziatrici per non danneggiare i fianchi ed il coperchio dell’unità. In alternativa le unità possono essere sollevate tramite l’ausilio di un carrello elevatore, infilando le forche di sollevamento nel pallet di appoggio (si veda la figura a pagina seguente). 1478 When unloading the unit, it is highly recommended to avoid any sudden move. When unloading or locating the chiller with a crane, pass bars through base frame lifting holes (marked with yellow arrows) and attach the necessary cable or chain lifting devices to the bar, ensuring that they are clamped firmly; protect the sides of the unit with boarding or material of a similar nature. Another method of lifting is obtained by using a forklift: fork must be inserted in the base pallet, and care must be taken in order that the fork does not hit the section base or panel (see the following picture). In any case be sure the method of lifting does not allow the unit to slip from chains and or slings and allow the pumping module to turn over or similar and slide from the lifting devices (see picture at the following page). Barre distanziatrici Spacing bars Protezione fiancate Protection boarding Att.ne: In tutte le operazioni di sollevamento assicurasi di aver saldamente ancorato l’unità, al fine di evitare ribaltamenti o cadute accidentali. Caution: be sure that the method of lifting does not allow the unit to slip from chains and slings and does not allow the unit to turn over or slide from lifting devices. 2.3 DISIMBALLAGGIO 2.3 UNPACKING L’imballo dell’unità deve essere rimosso con cura evitando di arrecare possibili danni alla macchina. I materiali che costituiscono l’imballo sono di natura diversa. legno, cartone, nylon ecc. E’ buona norma conservarli separatamente e consegnarli per lo smaltimento o l’eventuale riciclaggio, alle aziende preposte allo scopo e ridurre così l’impatto ambientale. When unpacking the unit pay attention not to damage the unit. The package is made up by different materials: wood, paper, nylon etc. It’s a good rule to keep them separately and deliver to the proper gathering centre in order to reduce their environmental impact. 1479 2.4 POSIZIONAMENTO 2.4 LOCATION E’ opportuno prestare attenzione ai punti seguenti per determinare il sito migliore ove installare l’unità ed i relativi collegamenti: - dimensioni e provenienza delle tubazioni idrauliche; - ubicazione dell’alimentazione elettrica; - accessibilità per le operazioni di manutenzione o riparazione; Consideration must be given to the following points when determining the most suitable site for the equipment installation: - location arrangement and size of water piping; - electrical power supply; - accessibility of space for servicing/maintenance and repair of the unit and/or its components; - floor loading strength and ability to support the operating weight of the unit; - possible objection to operating noise. - solidità del piano di supporto; - possibile riverbero delle onde sonore. Tutti i modelli della serie PSM sono progettati e costruiti per installazioni esterne. E’ buona norma creare una soletta di supporto di dimensioni adeguate a quelle dell’unità. Tale precauzione risulta indispensabile quando si voglia collocare l’unità su terreno instabile (terreni vari, giardini, ecc.). All PSM series units are designed and manufactured for external location It is advisable to create a proper basement, with a size similar to unit footprint. This solution is to be intended compulsory when locating the unit on the ground (gardens or similar, etc.). Le unità trasmettono al terreno un basso livello di vibrazioni: è comunque consigliabile interporre tra il telaio di base ed il piano di appoggio un nastro di gomma rigido. Qualora si necessitasse di un isolamento più spinto è opportuno l’impiego di supporti antivibranti (contattare la nostra azienda). Unit vibration level is very low: it is advisable however, to fit a rigid rubber band between basement and unit base-frame. If it is the case, it is possible to install anti-vibration mounts (spring or rubber), to keep vibrations at a very low level (contact our firm). Nastro di gomma Rubber band Soletta Concrete 1480 3. INSTALLAZIONE 3. INSTALLATION 3.1 SPAZI DI INSTALLAZIONE 3.1 CLEARANCES Per garantire un’adeguata accessibilità per le operazioni di manutenzione è necessario predisporre i seguenti spazi di servizio (si veda la figura nella pagina): In order to guarantee access to inner components for maintenance purposes it is necessary to observe the following clearances (see the picture in the page): - lato quadro elettrico: min. 1 metro. - lato opposto quadro elettrico: min. 1 metro per l’accessibilità alle pompe. - lato attacchi idraulici: min. 1 metro. - electric board side: min. 1 metre - electric board opposite side: min. 1 metre to allow pump access. - hydraulic connection side: min.1 metre. LEGENDA / LEGEND Quadro elettrico Electric board Connessioni idrauliche Hydraulic connections Per i modelli, 380, 690, 920 e 1100 fare riferimento ai fogli dimensionali For models 380, 690, 920 and 1100, please make reference to the dimensional drawings. 1481 3.2 RACCOMANDAZIONI GENERALI PER I COLLEGAMENTI IDRAULICI 3.2 GENERAL RECOMMENDATIONS FOR WATER PIPING CONNECTIONS Quando ci si appresta a realizzare il circuito idraulico, è buona norma attenersi alle seguenti prescrizioni e comunque rispettare la normativa nazionale o locale (si faccia riferimento agli schemi inclusi nel manuale). Unit water pipework must be installed in accordance with national and local regulation and code. Please follow the recommendations reported below, when designing the unit water piping circuit (please refer to the diagrams included in this manual). - Raccordare le tubazioni all’unità tramite giunti flessibili al fine di evitare la trasmissione delle vibrazioni e compensare le dilatazioni termiche. Verificare che la tubazione in arrivo dall’impianto sia collegata in corrispondenza della connessione di ingresso acqua. Verificare che la tubazione di mandata all’impianto sia collegata in corrispondenza della connessione di uscita acqua. - Piping should be connected to the unit with flexible joints, in order to avoid vibration transmission and compensate thermal expansion. Check that the pipe coming from the system is connected to the inlet water connection. Check that the pipe going to the system is connected to the outlet water connection. - Installare sulle tubazioni i seguenti componenti: • rubinetti d’arresto, indicatori di temperatura e pressione per la normale manutenzione e controllo. - On the piping should be installed the following devices: • isolating valves, temperature gauges, pressure gauges for the ordinary maintenance or servicing operations. • temperature gauges for inlet and outlet water temperature measurement. • shut-off valves to separate the unit from the hydraulic circuit. • pozzetti e termometri sulle tubazioni d’ingresso ed uscita per i rilievi di temperatura. • valvole di intercettazione (saracinesche) per isolare l’unità dal circuito idraulico. • valvole di sfiato, da collocare nelle parti più elevate del circuito idraulico, per permettere lo spurgo degli incondensabili. • valvola di carico automatica per il mantenimento della pressione del sistema dotata di filtro. E’ vivamente consigliata l’installazione di una valvola di sicurezza sul circuito idraulico. In caso di anomalie gravi nell’impianto (ad es. incendio) essa permetterà di scaricare il sistema evitando possibili scoppi. Collegare sempre lo scarico ad una tubazione di diametro non inferiore a quello dell’apertura della valvola, e convogliarlo in zone nelle quali il getto non possa recare danno alle persone. 1482 • vent valves, to be installed in the upper parts of the circuit, for air bleeding. • water filling group for circuit pressurisation with metallic filters. It is highly recommended to install a safety valve on hydraulic circuit. In case of dangerous situation (i.e. fire) the valve will discharge the system avoiding explosions. The valve must be connected to a vent pipe with a cross area equal or greater than the valve and must be directed into a safe zone in which no injuries can be done to people. CIRCUITO IDRAULICO CONSIGLIATO PER UNITA' PSM RECOMMENDED HYDRAULIC CIRCUIT FOR PSM SERIES UNIT 12 9 10 8 3 7 11 4 5 8 ENTRATA ACQUA UTENZE USER WATER INLET 7 11 5 USCITA ACQUA UTENZE USER WATER OUTLET LEGENDA / LEGEND 3 4 5 7 8 9 10 11 12 Valvola di sicurezza Valvola di ritegno Rubinetto Manometro acqua Termometro Filtro acqua Valvola di sfiato Giunto elastico Gruppo di riempimento impianto Safety valve Check valve Shut-off valve Water gauge Thermometer Water filter Vent valve Flexible coupling System filling group 1483 1484 3.3 COLLEGAMENTI ELETTRICI 3.3 ELECTRICAL CONNECTIONS 3.3.1 Generalità 3.3.1 Generality Prima di effettuare qualsiasi operazione su parti elettriche assicurarsi che non vi sia tensione. Before every operation on the electric section, be sure that the electric supply is disconnected. Verificare che la tensione di alimentazione corrisponda ai dati nominali dell’unità (tensione, numero di fasi, frequenza) riportati sulla targhetta a bordo macchina. L’allacciamento di potenza avviene tramite cavo tripolare e cavo di terra. Per l’ingresso dei cavi utilizzare il foro pretranciato posto alla base del montante della macchina stessa e sul quadro (si vedano i disegni dimensionali alla fine del manuale). It must be verified that electric supply is corresponding to the unit electric nominal data (tension, phases, frequency) reported on the label in the front panel of the unit. Power connections must be made using a three-wire cable + ground cable. For cable connection use the dedicated hole on the bottom of the corner pillar and at the bottom of the electric board (see dimensional drawing at the end of this manual). La sezione del cavo e le protezioni di linea devono essere conformi a quanto indicato nella apposita tabella nello schema elettrico allegato all’unità. Power cable and line protection must be sized according to the specification reported on the form of the wiring diagram enclosed with the unit. La tensione di alimentazione non deve subire variazioni superiori a ±5% e lo squilibrio tra le fasi deve essere sempre inferiore al 2%. Se ciò non dovesse verificarsi prendere contatto con la nostra Azienda per la scelta di opportune protezioni. The line voltage fluctuations must not be more than ±5% of the nominal value, while the voltage unbalance between one phase and another must not exceed 2%. If those tolerances should not be respected, please contact our Firm to provide proper devices. Il funzionamento deve avvenire entro i valori sopra citati: in caso contrario la garanzia viene a decadere immediatamente. Electric supply must be in the limits shown: in the opposite case warranty will terminate immediately. I collegamenti elettrici devono essere realizzati in accordo con le informazioni riportate sullo schema elettrico allegato all’unità e le normative vigenti. Il collegamento a terra è obbligatorio per legge. L’installatore deve provvedere al collegamento del cavo di terra con l’apposito morsetto sulla barra di terra situata nel quadro elettrico contrassegnato con PE. Electrical connections must be done according to the instructions reported on the wiring diagram enclosed with the unit and according to norms in force. Ground connection is compulsory. Installer must connect ground cable with a dedicated terminal on ground bar in the electric board (refer to the picture at the following page) labelled with PE. L’alimentazione del circuito degli ausiliari è derivata dalla linea di potenza tramite un trasformatore situato nel quadro elettrico. Il circuito degli ausiliari è protetto da appositi fusibili. The auxiliary circuit derives from the power supply through a transformer on the electrical panel. The auxiliary circuit is protected by fuses. 3.3.2 Collegamento elettrico dell’unità Collegare il cavo tripolare e di terra agli appositi morsetti nel quadro elettrico. Nella morsettiera sono presenti anche contatti per la segnalazione remota del funzionamento o del blocco delle pompe. Per tali collegamenti riferirsi allo schema elettrico dell’unità. L’installatore deve provvedere alla protezione della linea di alimentazione in accordo con la normativa vigente. 3.3.2 Unit electrical connection Three wire cable + ground cable must be connected to the dedicated terminals on the terminal block. Contacts for pump operation or failure remote signalling are located in the terminal block. For these connections refer to unit electrical drawing. Installer must protect electrical supply line according to the local regulation. 3.3.3 Consensi esterni 3.3.3 External interlock Qualora si desideri effettuare un ONOFF remoto dell’unità è necessario collegare il consenso esterno ai contatti 25-17. If a remote ON-OFF should be needed, it is necessary to connect external interlock to terminals 25-17. Nel caso non fosse presente alcun consenso esterno ponticellare i contatti 25-17 per permettere all’unità di avviarsi. If no external interlock should be present, make a bridge between terminals 25-17 in order to let the unit start. 1485 1486 4. AVVIAMENTO 4. START UP 4.1 CONTROLLI PRELIMINARI 4.1 PRE-START CHECK - Verificare che l’allacciamento elettrico sia stato eseguito in maniera corretta e che tutti i morsetti siano serrati strettamente. - Check that all power cables are correctly connected and all terminals are hardly fixed. - Verificare che la tensione sui morsetti RST sia di 400 V ± 5% (o quella di targa della unità in caso di tensioni speciali) . Se la tensione fosse soggetta a variazioni frequenti prendere contatto con la nostra Azienda per la scelta di opportune protezioni. - The voltage at the phase R S T clamps must be 400 V ± 5% (or value reported on the identification label for special voltage) . If this should not happen please contact our Firm. - Verificare che i collegamenti idraulici siano stati eseguiti in maniera corretta, rispettando le indicazioni sulle targhette a bordo macchina. - Check that all hydraulic connections are correctly installed and all indications on unit labels are observed. - Verificare che l’impianto idraulico sia stato sfiatato, eliminando ogni eventuale residuo di aria, caricandolo gradualmente e aprendo i dispositivi di sfiato sulla parte superiore, che l’installatore avrà avuto cura di predisporre (a tale riguardo si consulti la sezione 3.2). - The system must be purged in order to eliminate any air that might have remained in the unit by means of vent valves, previously installed (see paragraph 3.2). 4.2 MESSA IN FUNZIONE 4.2 START UP Prima di procedere alla messa in funzione chiudere il sezionatore generale. - Nel caso di unità con una sola pompa posizionare l’interruttore di marcia sulla posizione “I”. - Nel caso di unità con due pompe posizionare l’interruttore di marcia sulla posizione “1” o “2” a seconda che si desideri avviare la pompa n. 1 o n. 2. After having closed the main switch refer to the following procedure: - On the units with one pump only, turn the ON-OFF switch on the “I” position. - On the units with two pump turn the pump selector switch on the “1” or “2” position depending on which pump is called to start. Qualora l’unità non dovesse avviarsi: - verificare che il contatto 25-17 dei consensi esterni sia chiuso. - verificare che non siano intervenute le sicurezze a protezione delle pompe. If the unit should not start,: - check that the external interlock contact between terminal 25-17 is closed. - check that any cut out is coming from pump protective devices. 4.3 ARRESTO DEL GRUPPO 4.3 UNIT SWITCH OFF Per fermare l’unità portare il selettore marcia-arresto sulla posizione “0”. To stop the unit turn the pump selector to the “0” position. 5. LIMITI DI FUNZIONAMENTO 5. OPERATION LIMITS La tabella che segue indica limiti di funzionamento delle unità PSM in relazione alla temperatura dell’acqua, alla portata ed alle temperature ambientali. Following table shows operating limits concerning water flow, water temperatures, and ambient air temperatures 130 Temperatura ambiente minima Minimum ambient temperature °C Temperatura ambiente massima Maximum ambient temperature °C Temperatura minima acqua Minimum water temperature °C Temperatura massima acqua Maximum water temperature °C Portata massima Max water flow l/h (l/s) 165 MODELLO / MODEL 200 260 310 -10 40 4 90 22000 (6,111) 380 Temperatura ambiente minima Minimum ambient temperature °C Temperatura ambiente massima Maximum ambient temperature °C Temperatura minima acqua Minimum water temperature °C Temperatura massima acqua Maximum water temperature °C Portata massima Max water flow l/h (l/s) 22000 (6,111) 480 22000 (6,111) MODELLO / MODEL 690 920 25000 (6,944) 28000 (7,778) 1100 -10 40 4 90 61000 (16,944) 62000 (17,222) 62000 (17,222) 115000 (31,944) 115000 (31,944) 1487 1488 6. MANUTENZIONE E CONTROLLI PERIODICI 6. MAINTENANCE AND PERIODIC CHECKS 6.0 AVVERTENZE 6.0 IMPORTANT RULES Tutte le operazioni descritte in questo capitolo DEVONO ESSERE SEMPRE ESEGUITE DA PERSONALE QUALIFICATO. All this operation described in this chapter MUST BE DONE BY TRAINED PEOPLE ONLY Prima di effettuare qualsiasi intervento sull’unità o di accedere a parti interne, assicurarsi di aver tolto l’alimentazione elettrica. Before every operation of servicing on the unit, be sure that the electric supply is disconnected. Dopo le operazioni di manutenzione richiudere sempre l’unità tramite le apposite pannellature, fissandole con le viti di serraggio. After servicing operation close the unit with cover panels, fixing them with locking screws. 6.1 GENERALITA’ 6.1 GENERALITY E’ buona norma eseguire controlli periodici per verificare il corretto funzionamento dell’unità: - Verificare il funzionamento di tutte le apparecchiature di controllo e di sicurezza (mensilmente). - Controllare il serraggio dei morsetti elettrici sia all’interno del quadro elettrico che nelle morsettiere delle pompe. Devono essere periodicamente puliti i contatti mobili e fissi dei teleruttori e, qualora presentassero segni di deterioramento, vanno sostituiti (mensilmente). - Verificare che non vi siano perdite d’acqua nel circuito idraulico (mensilmente). - Se l’unità deve rimanere per un lungo periodo fuori servizio, scaricare l’acqua dalle tubazioni e dal serbatoio. Questa operazione è indispensabile qualora durante il periodo di fermata dell’unità si prevedono temperature ambiente inferiori al punto di congelamento del fluido utilizzato (tipica operazione stagionale). - Controllare il riempimento circuito acqua. (mensilmente). It is a good rule to carry on periodic checks in order to verify the correct working of the unit: - Check that safety and control devices work correctly (monthly). - Check all the terminals on the electric board and on the pumps are well locked. Periodic cleaning of the sliding terminals of the contactors should be done: if any damage is found, please replace the contactors (monthly). - Check there is no water leakage in the hydraulic system (monthly). - If the unit is to be expected to be stopped for a long period, hydraulic circuit should be emptied from all the tubes and buffer tank. This operation is compulsory if, during seasonal stop, ambient temperature is expected to go down below the freezing point of employed mixture (typical seasonal operation). - Check process water level (monthly). 7. MESSA FUORI SERVIZIO DELL’UNITA’ 7. PUTTING THE UNIT OUT OF SERVICE Quando l’unità sia giunta al termine della durata prevista e necessiti quindi di essere rimossa e sostituita, va seguita la seguente procedura: - la struttura ed i vari componenti, se inutilizzabili, vanno demoliti e suddivisi a seconda del loro genere merceologico. Tutto ciò per agevolare i centri di raccolta, smaltimento e riciclaggio e per ridurre al minimo l’impatto ambientale che tale operazione richiede. Once the unit is arrived at the end of its life and needs to be removed or replaced, the following procedure should be observed: - the frame and various components, if not usable any longer, have to be dismantled and subdivided according to their nature. These operations allow easy material recover and recycling process, reducing environmental impact. 8. RICERCA GUASTI 8. TROUBLE SHOOTING Nella tabella seguente vengono elencate le più comuni cause che possono provocare il blocco dell’unità, o quantomeno un funzionamento anomalo. La suddivisione viene fatta in base a sintomi facilmente individuabili. In the following table are reported the most common troubles that can cause the unit stop or an incorrect operation. Per quanto concerne i possibili rimedi, si raccomanda un’estrema attenzione nelle operazioni che si intendono eseguire: un’eccessiva confidenza può causare incidenti anche gravi a persone inesperte, per cui si consiglia, una volta individuata la causa, di richiedere il nostro intervento o quello di tecnici qualificati. Concerning the solutions, it is necessary to take an extreme care on the actions to adopt: an excessive confidence may cause serious accidents to inexperienced people. It is advisable, once the cause is detected, to contact our servicing people or trained people only. SINTOMO PROBLEM Il gruppo non si avvia Unit does not start CAUSA PROBABILE POSSIBILE RIMEDIO PROBABLE CAUSE CORRECTIVE ACTION Collegamento difettoso o contatti del sezionatore aperti Power failure or main switch open Verificare presenza di tensione e chiudere i contatti Check with tester for voltage Close main switch Mancanza dei consensi esterni Verificare la chiusura dei contatti 10 e 17; controllare altri eventuali consensi esterni Check the connection of terminals 10-17; check any other external control device External devices do not allow the start up Teleruttore della pompa diseccitato Pump contactor not energised Controllare la tensione ai capi della bobina del teleruttore e la continuità della bobina stessa Check contactor coil and replace if defective Intervento del salvamotore Controllare l’isolamento della pompa tra gli avvolgimenti e la massa, e tra gli avvolgimenti stessi Pump motor protection is open Check pump motor winding insulation 1489 DIMENSIONI DI INGOMBRO, PESI E CONNESSIONI IDRAULICHE OVERALL DIMENSIONS, WEIGHTS AND HYDRAULIC CONNECTIONS PSM 55÷130 DISTRIBUZIONE PESI E CONNESSIONI IDRAULICHE WEIGHT DISTRIBUTION AND HYDRAULIC CONNECTIONS G1 G2 G3 Modello Peso in funz. Model 130 1490 G4 Oper. weight "Win" "Wout" Ø Ø (kg) (kg) (kg) (kg) (kg) BSP F. BSP F. 675 161 168 177 169 3" 1 1/2" DIMENSIONI DI INGOMBRO, PESI E CONNESSIONI IDRAULICHE OVERALL DIMENSIONS, WEIGHTS AND HYDRAULIC CONNECTIONS PSM 165 DISTRIBUZIONE PESI E CONNESSIONI IDRAULICHE WEIGHT DISTRIBUTION AND HYDRAULIC CONNECTIONS G1 G2 G3 Modello Peso in funz. Model 165 G4 Oper. weight "Win" "Wout" Ø Ø (kg) (kg) (kg) (kg) (kg) BSP F. BSP F. 866 215 210 218 223 3" 1 1/2" 1491 DIMENSIONI DI INGOMBRO, PESI E CONNESSIONI IDRAULICHE OVERALL DIMENSIONS, WEIGHTS AND HYDRAULIC CONNECTIONS PSM 200÷480 DISTRIBUZIONE PESI E CONNESSIONI IDRAULICHE WEIGHT DISTRIBUTION AND HYDRAULIC CONNECTIONS G1 G2 G3 Modello Peso in funz. Model 1492 G4 Oper. weight "Win" "Wout" Ø Ø (kg) (kg) (kg) (kg) (kg) BSP F. BSP F. 200 1073 287 242 249 295 3" 2" 260 1118 291 261 268 298 3" 2" 310 1118 291 261 268 298 3" 2 1/2" 480 1163 294 280 287 302 3" 3" DIMENSIONI DI INGOMBRO, PESI E CONNESSIONI IDRAULICHE OVERALL DIMENSIONS, WEIGHTS AND HYDRAULIC CONNECTIONS PSM 380÷1100 DISTRIBUZIONE PESI E CONNESSIONI IDRAULICHE WEIGHT DISTRIBUTION AND HYDRAULIC CONNECTIONS G1 G2 G3 Modello Peso in funz. Model G4 "Win" Oper. weight "Wout" Ø Ø (kg) (kg) (kg) (kg) (kg) A BSP F. BSP F. 380 1559 229 286 580 464 817 4” 3” 690 1579 235 295 584 465 837 4” 3” 920 1623 249 316 592 466 861 4” 4” 1100 1639 254 324 595 466 861 4” 4” 1493 DIMENSIONI DI INGOMBRO, PESI E CONNESSIONI IDRAULICHE OVERALL DIMENSIONS, WEIGHTS AND HYDRAULIC CONNECTIONS PSM 380÷1100 DISTRIBUZIONE PESI E CONNESSIONI IDRAULICHE WEIGHT DISTRIBUTION AND HYDRAULIC CONNECTIONS G1 G2 G3 Modello Peso in funz. Model 1494 G4 "Win" Oper. weight "Wout" Ø Ø (kg) (kg) (kg) (kg) (kg) A BSP F. BSP F. 380 1629 239 299 606 485 871 4” 3” 690 1666 248 312 616 490 891 4” 3” 920 1750 268 341 638 503 973 4” 4” 1100 1784 277 353 647 507 973 4” 4” CIRCUITO IDRAULICO DELLE UNITA' PSM PSM UNITS HYDRAULIC CIRCUIT LEGENDA / LEGEND 1 2 3 4 5 6 7 8 ¤ Pompa di circolazione Vaso di espansione Valvola di sfiato Valvola di ritegno Rubinetto a sfera Serbatoio Resistenza elettrica Resistenza elettrica serbatoio Opzionale Circulating pump Expansion vessel Vent valve Check valve Ball shut-off valve Tank Electric heater Tank electric heater Optional 1495 DATI TECNICI GENERALI TECHNICAL DATA Dati tecnici - Technical data Portata nominale acqua Nominal water flow Prevalenza utile External available pressure Capacità serbatoio Tank water volume Capacità vaso di espansione Expansion vessel volume Dati elettrici - Electrical data Potenza massima assorbita Maximum absorbed power Corrente massima allo spunto Maximum starting current Corrente massima assorbita Full load current Alimentazione elettrica Power supply 130 MODELLO / MODEL 165 200 l/s (l/h) 3,333 12000 4,167 15000 kPa 154 I 260 310 4,167 15000 5,833 21000 6,250 22500 179 179 204 276 400 600 700 700 700 I 18 18 18 18 18 kW 1,5 1,5 1,5 2,2 3,1 A 22,4 22,4 22,4 24,9 51,5 A 4,3 4,3 4,3 5,3 6,6 400V/3~/50 400V/3~/50 400V/3~/50 400V/3~/50 400V/3~/50 1003 1003 1104 1104 1104 1053 1053 1154 1154 1154 1600 1600 2100 2100 2100 260 302 358 404 404 V/~/Hz Dim. e pesi - Dimens. & Weight Lunghezza Length mm Profondità Width mm Altezza Heigth mm Peso Weight kg Dati tecnici - Technical data Portata nominale acqua Nominal water flow Prevalenza utile External available pressure Capacità serbatoio Tank water volume Capacità vaso di espansione Expansion vessel volume Dati elettrici - Electrical data Potenza massima assorbita Maximum absorbed power Corrente massima allo spunto Maximum starting current Corrente massima assorbita Full load current Alimentazione elettrica Power supply 480 l/s (l/h) 13,611 49000 13,889 50000 14,583 52500 23,333 84000 23,333 84000 kPa 163 176 281 213 294 I 1100 700 1100 1100 1100 I 25 18 25 25 25 kW 4 5,5 7,5 9,2 14 A 56,6 72 148,8 180 390 A 9,6 12 16 19 30 400V/3~/50 400V/3~/50 400V/3~/50 400V/3~/50 400V/3~/50 2275 1104 2275 2275 2275 1205 1154 1205 1205 1205 2078 2100 2078 2078 2078 568 448 606 690 736 V/~/Hz Dim. e pesi - Dimens. & Weight Lunghezza Length mm Profondità Width mm Altezza Heigth mm Peso Weight kg 24 BLUE BOX 1496 MODELLO / MODEL 690 920 380 1100 PREVALENZE UTILI EXTERNAL AVAILABLE PRESSURE 130 MODELLO / MODEL 165-200 260 310 [l/h] [l/s] 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 15000 16000 17000 18000 19000 20000 21000 22000 23000 24000 25000 26000 27000 28000 29000 30000 0,28 0,56 0,83 1,11 1,39 1,67 1,94 2,22 2,50 2,78 3,06 3,33 3,61 3,89 4,17 4,44 4,72 5,00 5,28 5,56 5,83 6,11 6,39 6,67 6,94 7,22 7,50 7,78 8,06 8,33 234 230 225 220 214 207 201 194 187 179 172 163 154 145 134 121 107 243 241 236 231 225 218 211 204 197 189 181 172 302 299 295 291 288 284 279 274 269 262 256 248 240 Ext. Förderhöhe Pression statique 232 228 222 214 204 193 181 168 154 139 124 107 89 71 51 Wassermenge Débit d'eau BLUE BOX 25 1497 PREVALENZE UTILI EXTERNAL AVAILABLE PRESSURE MODELLO / MODEL 480 690 920 380 1100 [l/h] 28000 30000 32000 34000 36000 38000 40000 42000 44000 46000 48000 50000 52000 54000 56000 58000 60000 62000 64000 66000 68000 70000 72000 74000 76000 78000 80000 82000 84000 86000 88000 90000 92000 94000 96000 98000 100000 102000 104000 106000 108000 110000 112000 114000 115000 219 216 213 209 204 199 193 187 181 174 167 160 152 144 135 126 116 276 270 262 254 245 235 225 214 202 189 176 162 148 133 117 101 84 344 340 335 331 326 322 317 311 305 299 292 284 275 266 256 246 234 269 266 263 260 257 254 251 247 244 240 236 232 228 223 218 213 208 202 196 190 184 177 170 163 155 147 139 131 123 114 105 101 7,78 8,33 8,89 9,44 10,00 10,56 11,11 11,67 12,22 12,78 13,33 13,89 14,44 15,00 15,56 16,11 16,67 17,22 17,78 18,33 18,89 19,44 20,00 20,56 21,11 21,67 22,22 22,78 23,33 23,89 24,44 25,00 25,56 26,11 26,67 27,22 27,78 28,33 28,89 29,44 30,00 30,56 31,11 31,67 31,94 347 344 341 338 335 332 329 326 323 319 316 312 308 304 299 295 290 285 279 274 268 262 255 248 241 234 227 219 211 202 194 189 400 350 300 Ext. Förderhöhe Pression statique 250 200 150 100 50 7,2 8,6 10,0 11,4 12,8 14,2 15,6 16,9 18,3 19,7 Wassermenge Débit d'eau 1498 21,1 22,5 23,9 25,3 26,7 28,1 29,4 30,8 32,2 60270000112 Psm_04-2014
advertisement
Key Features
- Centrifugal pumps
- Buffer tank
- Expansion vessel
- Outdoor installation
- Protection against weather
- Easy Maintenance