EMX INDUSTRIES, INC. BPE-50 Photo Beam Instructions

EMX INDUSTRIES, INC. BPE-50 Photo Beam Instructions

Below you will find brief information for Photo Beam BPE-50 BPE-50. The BPE-50 Photo Beam is a wireless photo beam security system that uses a transmitter and receiver to detect intruders. The system is easy to install and can be used in a variety of security applications. The BPE-50 is designed for use in outdoor applications and can withstand harsh weather conditions.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Photo Beam BPE-50 BPE-50 Instructions | Manualzz
BPE-50™
Photo Beam with battery
powered Transmitter
Product Overview
The BPE-50 photo beam system uses 12 -24 VDC/AC on
the transmitter and receiver with the transmitter offering the
option of using the two 3.6 Volt batteries for power
(included). Recommended battery replacement is the Varta
ERAA 3V6 2400.
Connections (Fig 1)
1
2
3
Never use product as sensing devices for personnel protection.
Doing so could cause serious injury or death.
These sensors do NOT include the self-checking redundant circuitry
necessary to allow their use in personnel safety applications. A sensor failure or
malfunction can cause either an energized or de-energized sensor output
condition. UL 325 Non-compliant
Technical Specifications
Relay Type
Temperature
Wavelength
Frequency
Environmental
Not UL325 compliant
Operating Instructions
This product is an accessory or part of a system.
Always read and follow the manufacturer’s
instructions for the equipment you are connecting
this product to. Comply with all applicable codes and safety
regulations. Failure to do so may result in damage, injury or
death!
Detect Indicator
Connector
Relay contact
Housing Material
Size
Range
Detection Angle
Sensitivity
Detection delay
Reset delay
12-24 VDC 24 VAC (2-3.6 Volt Lithium
Batteries for transmitter optional
/included)
Expected battery life up to 2 years
approx.
RX = <50mA standby 100mA activated, TX
= < 500uA
2 Form C DPST contact rating .5A @ 24VDC
/ 120VAC
-20C – 55C
880 nm
High 90 Hz Low 48 Hz (Ext power 787 Hz)
IP 65
Red LED
Terminal block
0.5Amp
PA6 30% FG
H 4.4in (112mm) x W 2.05in (52mm) x D
1.3in (33mm)
Up to 50 feet (if TX on 12/24 V 90 feet)
+/- 5%
Jumper J1 on receiver
< 30 ms
< 120 ms
Security edge
(join if not used)
WARNING … Not to be used for Personnel Protection
Current Draw
Receiver
Power Positive (+)
Power Negative (-)
Internal Relay
Normally Open
Internal Relay
Common
Internal Relay
Normally Closed Output
(join if not used)
4
Power Supply
Transmitter
Power Positive (+)
Power Negative (-)
NC Security Contact
5
Security edge
(join if not used)
Terminal connection as viewed from the front, left to right
Jumper Configuration (Fig 2)
Jumper
ON
Receiver J1 (Gain)
Normal
Transmitter J2
Fast
(frequency)
Transmitter J3 (Security Not
edge)
connected
Jumper Settings for figure 2
Lens Alignment (Fig 3)
OFF
High
Slow
Installation (Fig 4)
Both the transmitter and receiver lenses may be aligned
left, right or straight ahead. To align gently pull the lens
stem straight out from mounting position and snap back
into place pointing in the desired direction.
Connected
Place the BPE-50 away from heat and electromagnetic
sources for best operation. Mount units a minimum of
12 inches 30 cm from the floor.
Apply power to the units and set jumpers per instruction
on see figures 1 and 2.
Test installation to insure desired and proper operation.
All local and operator manufacturer installation
instructions should be followed.
The BPE-50 transmitter may be hooked up to an edge
sensor for alternative activation operation.
Units should be placed a minimum of 12 – 16 inches
from the floor. Across from and lenses facing each
other. The receiver red detect LED will be on when the
beam is broken or not aligned.
4564 Johnston Parkway
Cleveland, Ohio 44128
United States of America
WEB http://www.emxinc.com
E-mail [email protected]
Telephone (216) 518-9888
Fax (216) 518-9884
When transmitter frequency is set to low battery
life will be increased. The range will be reduced
at this setting. However when the transmitter is
powered by 12/24 VDC or 24 VAC the range will
be maximum regardless of the jumper setting.
BPE-50 Instructions
rev 1.1
06/19/2013
The BPE-50 does not require any special care, but it is
necessary to check condition occasionally to insure they
are operating correctly. (Batteries are still operational if
on battery power)
Recommended battery replacement is the Varta ERAA 3V6
2400.

advertisement

Key Features

  • Wireless photo beam security system
  • Easy to install
  • Weatherproof
  • 12-24 VDC/AC power
  • Optional battery power
  • Range up to 50 feet

Frequently Answers and Questions

What is the range of the BPE-50 Photo Beam?
The range of the BPE-50 Photo Beam is up to 50 feet. However, if the transmitter is powered by 12/24 VDC or 24 VAC, the range will be maximum regardless of the jumper setting.
What type of batteries are used in the BPE-50 Photo Beam?
The BPE-50 Photo Beam uses two 3.6 Volt batteries for power. Recommended battery replacement is the Varta ERAA 3V6 2400.
How do I align the lenses of the BPE-50 Photo Beam?
To align the lenses, gently pull the lens stem straight out from the mounting position and snap back into place pointing in the desired direction.