Energy PDU
PE1216
PE1324
•
•
NEMA: 20A
(derated 16A) ; IEC: 16A
• 16 Outlets
• 0U
About ATEN
ATEN has specialized in connectivity and management solutions in information technology, professional audio/video and
green energy business since its establishment in 1979, and has been a worldwide leader in the KVM switch market.
ATEN offers a broad range of solutions to meet the needs of consumers, small office/home office (SOHO) users, and small
and medium sized business (SMB) customers. ATEN’s state-of-the-art KVM switches include Cable KVM, Desktop KVM,
Rack KVM and KVM Extenders. ATEN also offers LCD KVM switches to meet the needs of server rooms in tandem with
the ALTUSEN™ line of high-end server management solutions for the enterprise-level KVM switch market. Furthermore,
ATEN's Over the NET ™ solutions allow you to effectively manage IT infrastructure from anywhere in the world. ATEN also
offers the VanCryst ™ range of video integrated solutions for a wide variety of corporate, commercial, and home theater
applications. Our high-quality audio/video switches, splitters, extenders, and converters are available with various audio,
video and control interfaces.
At ATEN, we are committed to protecting the environment. To this end, ATEN NRGence™ line is the latest evolution of
energy intelligence. A green energy solution for data centers that provides instant real-time power management control
and energy-saving efficiency, by allowing you to easily upgrade your current IT resources quickly and cost-effectively.
ATEN delivers and we make customer care a priority. We are committed to providing the best customer support available
in the industry.
NRGence™ Rack PDU Products
Current with increasing energy challenges, including rising demand, growing consumption, and ensuring sufficient
energy supplies, energy-saving issues have become an important global concern. In fact, power used in the server room
represents a large proportion of the total consumption of electricity in any office building. Efficiently reducing sever
room power consumption and lowering data center energy overheads is therefore not only a great benefit in terms of
environmental protection but also it is essential to saving on business operation costs. ATEN offers various series of PDU
and energy management solution – allowing you to easily upgrade your server room to a green data center quickly and
cost-effectively.
PDU Comparison
Series
Series 1
Models
PE1216 PE1324
Outlet
16
24
Rack Space
0U
Daisy-chain
Remote Power Control
Metering Capability
Local console access
Thresholds & Alarms
Auto Ping
Environment
Monitoring
eco Sensors Support
API Support
V*
Series 6
PE6108/PE6208 PE6216 PE6324
8
16
24
1U
0U
V
Series 8
PE8108/PE8208 PE8216 PE8324
8
16
24
1U
0U
V
V
Bank & PDU Level
Outlet, Bank & PDU Level
V
V
V
V
Series 98
PE98224/PE98324
24
0U
V
V
V
V
V
V
V
V
V*
V
V
V
V
V
* Used in conjunction with Energy Box
•
Function
Inlet
Current
Monitor
Environment
Monitor
LAN
Model
V
Setup
Energy Box
Power Adapter DC 5V (1.8m)
4 x Energy Sensor Connection port
Monitoring Range
Input
4 x Environment Sensor
Connection port
1 x RJ-45 Female with LEDs
100–240V; 50/60Hz; 0A to 32A (per port)
LED Display Resolution 0.1A
Precision: ±[email protected] ~ 1A, ±1%@ >1A
Nominal Input Power
Outlet
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Network Protocols: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP,
NTP, DNS, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V3
•
•
16 x IEC
320 C13
200–240V,
50/60Hz, 20A
PE6108A
15A, 100 – 120V UL de-rated 12A
NEMA 5-15 Plug
IEC
320
C20
PE6108B
200–240V,
50/60Hz,16A
16 x IEC
320 C13
200–240V,
50/60Hz, 16A
15A, 200 – 240V UL de-rated 12A
NEMA 6-15 Plug
PE1324G
24 x IEC
320
C13
200–240V, 50/60Hz
Per Bank 16A
Total 32A
The specification and pictures are subject to change without notice.
Nominal Input Power
PE6108G
10A, 200 – 240V IEC320 C14 Plug
PE6208A
20A, 100 – 120V UL de-rated 16A
NEMA 5-20 Plug
PE6208B
20A, 200 – 240V UL de-rated 16A
NEMA 6-20 Plug
PE6208G
PE6216B
16A, 200 – 240V IEC320 C20 Plug
20A, 200 – 240V NEMA L6-20P Plug
Power Distribution
•
Space saving rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 256 (PE8216) or
384 (PE8324) outlets*
• 2 x 7 segment front panel LED shows Station and Outlet IDs; 3 x
7 segment LED shows current, voltage or power dissipation at
PDU level*
•
•
3 x 7 segment front panel LED shows Current / IP Address
Remote users can monitor outlet status via web pages on their
browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets –
the user interface is still accessible even when an overload condition
trips the devices' circuit breakers
•
Two-level password security
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Out of Band operation via modem access*
• Network Interfaces: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP,
ARP*, NTP, DNS, Telnet*, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V3
• IPv6 support*
Operation
Rack
Space
# of Bank
x Nominal
Output
Power
# of Outlet
Socket
x Type
Switching
Capability
Metering
Capability
Regulatory
Approval
1U
1 x 15A
100 – 120V
8 x NEMA5-15R
Per Outlet
PDU Level
UL, PSE
1U
1 x 15A
200 – 240V
8 x IEC 320 C13
Per Outlet
PDU Level
UL, PSE
1U
1 x 10A
200 – 240V
8 x IEC 320 C13
Per Outlet
PDU Level
TUV
1U
1 x 20A
100 – 120V
8 x NEMA 5-20R
Per Outlet
PDU Level
UL, PSE
1U
1 x 20A
200 – 240V
7 x IEC 320 C13 +
1 x IEC 320 C19
Per Outlet
PDU Level
UL, PSE
1U
1 x 16A
200 – 240V
7 x IEC 320 C13 +
1 x IEC 320 C19
Per Outlet
2 x IEC 320 C19 +
14 x IEC 320 C13
Per Outlet
0U
Local and Remote power outlet control (On, Off, Power Cycle) by
individual outlets and outlet groups*
• Outlet group support at the PDU and Daisy-chain levels – the same
action can be performed on a specified group of outlets at the same
time*
• Supports redundant power management via daisy chaining and
outlet groups*
• On/Off scheduling for individual outlets and outlet groups. Power
management tasks can be scheduled on a daily, weekly, monthly,
or user-specified times basis*
• Supports multiple power control methods – Wake on LAN, System
After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and
delay time for each outlet to allow equipment to be turned on in
the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Firefox, Chrome, Safari)
• Telnet and SSH access for text menu configuration and outlet level
switching / monitoring*
• Local console access support*
•
1 x 20
A
200 – 240V
1 x 16A
200 – 240V
2 x IEC 320 C19 +
14 x IEC 320 C13
PDU Level
TUV
Java GUI AP program provided for non-browser connectivity*
RTC support to keep the timer running during times of no power
• Supports up to 8 user and 1 administrator accounts
• Up to 64 user accounts - up to 32 concurrent logins*
Management
Power status measurement at PDU and outlet levels
Current, voltage, power dissipation, and energy consumption
displayed in a browser based UI for monitoring at the outlet,
group*, PDU, and daisy-chain* levels
• Alert threshold notification for selected events (On, Off,
Recycle, Failure, etc.), via audio alarm and blinking LEDs
(locally), SMTP, SNMP trap notification, and digital output*
• Environment monitoring – supports external temperature /
temperature & humidity sensors for rack temperature and
humidity monitoring
• Current, voltage, power dissipation, energy consumption,
temperature, and humidity threshold level setting
• Auto-Ping pings a device to determine its status, if the ping
test fails after a set amount of time- it automatically takes an
action assigned*
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis
• Event logging and syslog support
• Integration with ALTUSEN CC2000 Management software
and KVM devices*
• Supports Management Information Base (MIB) files for SNMP
• API for 3rd party software centralized control integration*
• Upgradeable firmware
• Multi-language support
•
•
Security
Two-level (PE8108/PE8208) / Three-level (PE8216/PE8324)
password security
• IP/MAC Filter for enhanced security protection*
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS, TACACS+, LDAP,
LDAPS and Active Directory*
•
*Features supported by PE8216/PE8324 only
Model
Nominal Input Power
# of Bank x Nominal
# of Outlet Socket x Type
Output Power
Switching
Capability
Metering Regulatory
Capability Approval
PE8108A
15A, 100 – 120V UL de-rated 12A
NEMA 5-15 Plug
1 x 15A 100 – 120V
8 x NEMA5-20R
Per Outlet
Per Outlet UL, PSE
PE8108B
15A, 200 – 240V UL de-rated 12A
NEMA 6-15 Plug
1 x 15A 200 – 240V
8 x IEC 320 C13
Per Outlet
Per Outlet UL, PSE
PE8108G
10A, 200 – 240V IEC320 C14 Plug 1 x 10A 200 – 240V
8 x IEC 320 C13
Per Outlet
Per Outlet TUV
PE8208A
20A, 100 – 120V UL de-rated 16A
NEMA 5-20 Plug
1 x 20A 100 – 120V
8 x NEMA5-20R
Per Outlet
Per Outlet UL, PSE
PE8208B
20A, 200 – 240V UL de-rated 16A
NEMA 6-20 Plug
1 x 20A 200 – 240V
7 x IEC 320 C13 + 1 x IEC 320 C19
Per Outlet
Per Outlet UL, PSE
PE8208G
16A, 200 – 240V IEC320 C20 Plug 1 x 16A 200 – 240V
7 x IEC 320 C13 + 1 x IEC 320 C19
Per Outlet
Per Outlet TUV
FCC, TUV-CB*, TUV
-UL*, TUV-PSE*
Per Outlet
Per Bank
CE
TUV-CB*
PE8216B
20A, 200 – 240V
NEMA L6-20P Plug
1 x 20A 200 – 240V
2 x IEC 320 C19 + 14 x IEC 320 C13 Per Outlet
Per Outlet
FCC, TUV-CB*,
TUV-UL*, TUV-PSE*
PE8216G
16A, 200 – 240V IEC60309 Plug
1 x 16A 200 – 240V
2 x IEC 320 C19 + 14 x IEC 320 C13 Per Outlet
Per Outlet
CE
TUV-CB*
PE8324B
30A, 200 – 240V
NEMA L6-30P Plug
2 x 16A 200 – 240V
3 x IEC 320 C19 +
21 x IEC 320 C13
Per Outlet
FCC, TUV-CB*
TUV-UL*, TUV-PSE*
PE8324G
32A, 200 – 240V IEC60309 Plug
2 x 16A 200 – 240V
3 x IEC 320 C19 + 21 x IEC 320 C13 Per Outlet
16A, 200 – 240V IEC60309 Plug
0U
PE6324B
30A, 200 – 240V NEMA L6-30P Plug
0U
2 x 16A
200 – 240V
3 x IEC 320 C19 +
21 x IEC 320 C13
Per Outlet
Per Bank
FCC, TUV-CB, TUVUL, TUV-PSE
PE6324G
32A, 200 – 240V IEC60309 Plug
0U
2 x 16A
200 – 240V
3 x IEC 320 C19 +
21 x IEC 320 C13
Per Outlet
Per Bank
CE, TUV-CB*
The specification and pictures are subject to change without notice.
NEMA: 30A (derated 24A) ;
IEC: 32A
24 Outlets
• 0U
•
Per Bank
PE6216G
* Ready for compliance.
NRGence Catalog_cs3-2.indd 1-4
NEMA: 20A (derated 16A) ;
IEC: 16A
• 8 Outlets
• 1U
•
Security
Power status measurement at PDU level
LED indicators for current and IP address at the PDU device level
• Real-time current, voltage, and kWH displayed in a browsed-based
UI for monitoring at the PDU level
• Environment monitoring – supports external temperature /
temperature & humidity sensors for rack temperature and
humidity monitoring
200–240V,
50/60Hz, 20A
200–240V,
50/60Hz, 32A
Current, voltage, power dissipation, energy consumption,
temperature, and humidity threshold level setting
• Naming support for outlets
• User outlet access assignment on an outlet-by-outlet basis
• Event logging and syslog support
• Supports Management Information Base (MIB) files for SNMP
• Upgradeable firmware
• Multilanguage support
•
NEMA
L6-20
IEC
60309
32A
•
•
PE1216B
200–240V, 50/60Hz
Per Bank 15A
Total 30A
PE8324
•
NEMA: 30A (derated 24A) ;
IEC: 32A
• 24 Outlets
• 0U
Management
Model
24 x IEC
320
C13
PE8208
•
Remote power outlet control (On, Off, Power Cycle) by individual
outlets
• Supports multiple power control methods – Wake on LAN, System
After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and
delay time for each outlet to allow equipment to be turned on in
the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Firefox, Chrome, Safari)
• RTC support to keep the timer running during times of no power
• Supports up to 8 user and 1 administrator accounts
100–120V,
50/60Hz ,20A
200–240V,
50/60Hz, 30A
PE6324
•
•
Nominal Output
Power
NEMA: 20A (derated 16A) ;
IEC: 16A
16 Outlets
• 0U
•
PE6208
•
16 x NEMA
5-15R
NEMA
L6-30P
NEMA: 15A (derated 12A) ;
IEC: 10A
• 8 Outlets
• 1U
•
100–120V,
50/60Hz, 20A
PE1324B
•
Operation
NEMA
5-20P
PE1216G
PE8216
•
NEMA: 20A (derated 16A) ;
IEC: 16A
• 16 Outlets
• 0U
•
PE1216A
Outlet, Bank & PDU
Level
V
V
4 Energy Sensor ports for Energy PDU current monitoring ( 0A to 32A per port )
4 Environment Sensor ports for temperature, humidity and differential pressure monitoring
• Space saving 0U/1U rack mount design
• Remote real-time current management and monitoring
• Current threshold level setting provision
• Name assignment to individual PDU
• Wide Management Option Range
• Remote management via IP network with Web Brower, eco Sensors software or 3rd party SNMP manager
• Exceed threshold alert through
• Local: audio alarm and LED light blinking
• Remote: SMTP/SNMP trap/Syslog
•
V
V*
CC2000 support
Energy Box EC1000
NRGence™ Energy Box is an intelligent 1U (0U vertical hook also available) power monitor unit which can monitor the current from
4 Energy PDUs and 4 temperature, humidity, or differential pressure sensors. It is a standalone Over IP monitor box that can be
controlled by Web UI or eco Sensors software. Conveniently deploying Energy Boxes in your rack, connected to Energy PDUs, allows
all current information from the PDUs to be collated and displayed on the Energy Box for easy viewing and monitoring.
PE8108
•
•
Space saving rack mount design with rear mounting
• IEC or NEMA outlet models
• 3 x 7 segment front panel LED shows Current / IP Address
• Remote users can monitor outlet status via web pages on their
browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets
– the user interface is still accessible even when an overload
condition trips the devices' circuit breakers
•
The Energy PDU contains 16/24 AC outlets and is available in various IEC or NEMA socket configurations. It features a space-saving 0U
design that allows it to be mounted vertically on the outside of the rack, resulting in a more efficient use of server room space.
• Space saving 0U rack mount design
• IEC or NEMA outlet models
PE6216
•
NEMA: 20A (derated 16A) ;
IEC: 16A
• 8 Outlets
• 1U
Power Distribution
Energy PDU PE1216/PE1324
eco PDU
PE6108
NEMA: 15A (derated 12A) ;
IEC: 10A
• 8 Outlets
• 1U
NEMA: 30A
(derated 24A) ; IEC: 32A
• 24 Outlets
• 0U
Our Vision
“Simply Better Connections” has always been at the heart of the ATEN brand. It means providing innovative solutions
for you to make better connections, efficiently and seamlessly, to the information and people that you value. As a result,
ATEN connects you to the world, anytime and anywhere, by providing technologies that enable you to share and to care.
ATEN makes professional and personal life easier, simpler and better connected.
PE8108/PE8208
PE8216/PE8324
eco PDU
* Ready for compliance.
Per Outlet
Per Outlet CE, TUV-CB*
The specification and pictures are subject to change without notice.
2012/4/17 11:29:47 AM
PE98224/PE98324
•
Energy Management Software
eco PDU
eco Sensors
Optional Accessories
Environment Sensors
ATEN provides various environment sensors to work with NRGence™ PDU. The sensors enable you to get status feedback
on temperature, humidity or differential pressure.
Part No.
Sensor
EA1140
Temperature
EA1240
Temperature / Humidity
EA1340
Differential Pressure /
Temperature
PE98224
PE98324
•
•
NEMA: 20A (derated 16A) ;
IEC: 16A 3 Phase
• 24 Outlets
• 0U
NEMA: 30A (derated 24A) ;
IEC: 32A 3 Phase
24 Outlets
• 0U
•
Energy lntelligence PDU for Data Centers
Cable Holders
For added safety, use ATEN Lok-U-Plug cable holders to secure the cables from your attached devices in place on the Energy
PDU unit. Use only the ATEN Lok-U-Plug cable holders that have been specifically designed to work with the Energy PDU.
Using any other kind of cable securing device could be highly dangerous.
Part No.
Cable Holder
2X-EA07
Lok-U-Plug (10 PCS per pack) Patent Pending!
Power Distribution
Management
Space saving 0U rack mount design
• IEC or NEMA outlet models
• Daisy chain up to 15 additional stations for up to 384 outlets
• 2 x 7 segment front panel LED shows Station and Outlet IDs
• 3 x 7 segment LED shows current, voltage or power dissipation at
PDU level
• Remote users can monitor outlet status via web pages on their
browsers
• Safe shutdown support
• Separate power for the unit's own power and its power outlets –
the user interface is still accessible even when an overload condition
trips the devices' circuit breakers
•
•
Remote Access
Remote power control via TCP/IP and a built in 10/100 Ethernet port
Out of Band operation via modem access
• Network Protocols: TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP,
ARP, NTP, DNS, Telnet, auto sense, Ping
• eco PDU Power Management software – eco Sensors
• Supports SNMP Manager V3
• IPv6 support
•
•
Operation
Local and Remote power outlet control (On, Off, Power Cycle)
by individual outlets and outlet groups
• Outlet group support at the PDU and Daisy-chain levels – the
same action can be performed on a specified group of outlets at
the same time
• Supports redundant power management via daisy chaining and
outlet groups
• On/Off scheduling for individual outlets and outlet groups. Power
management tasks can be scheduled on a daily, weekly, monthly,
or user-specified times basis
• Supports multiple power control methods – Wake on LAN, System
After AC Back, Kill the Power
• Power-on sequencing - users can set the power on sequence and
delay time for each outlet to allow equipment to be turned on in
the proper order
• Easy setup and operation via a browser-based user interface
• Multibrowser support (IE, Firefox, Chrome, Safari)
• Telnet and SSH access for text menu configuration and outlet
level switching / monitoring
• Local console access support
• Java GUI AP program provided for non-browser connectivity
• RTC support to keep the timer running during times of no power
• Up to 64 user accounts - up to 32 concurrent logins
•
Corporate Headquarters
ATEN International Co., Ltd.
3F., No.125, Sec. 2, Datong Rd., Sijhih District.,
New Taipei City 221, Taiwan
Phone: +886-2-8692-6789 Fax: +886-2-8692-6767
www.aten.com E-mail: [email protected]
U.S.A. Subsidiaries:
Japan Subsidiary :
ATEN Technology Inc.
ATEN Japan Co., Ltd.
19641 DaVinci, Foothill Ranch, CA 92610, U.S.A
Phone: +1-949-428-1111 Fax: +1-949-428-1100
www.aten-usa.com E-mail: [email protected]
ATEN Bldg. 8-4, Minami-senjyu 3-chome, Arakawa-ku,
Tokyo 116-0003 Japan
Phone: +81-3-5615-5810 Fax: +81-3-3891-3810
www.atenjapan.jp E-mail: [email protected]
ATEN New Jersey Inc.
155 Pierce Street, Somerset, NJ 08873, U.S.A
Phone: +1-732-356-1703 Fax: +1-732-356-1639
www.aten-usa.com E-mail: [email protected]
ATEN New Jersey Inc.
155 Pierce Street, Somerset, NJ 08873, U.S.A
Phone: +1-732-356-1703 Fax: +1-732-356-1639
www.aten-usa.com E-mail: [email protected]
Korea Subsidiary :
ATEN Korea.,Ltd.
B-303, Gabeul Great Valley, 60-5, Gasan-dong,
Geumcheon-gu, Seoul, Korea; 153-801
Phone: +82-2-467-6789 Fax: +82-2-467-9876
www.aten.co.kr E-mail: [email protected]
Belgium Subsidiary :
ATEN Infotech N.V.
Mijnwerkerslaan 34, 3550 Heusden-Zolder, Belgium
Phone: +32-11-531543 Fax: +32-11-531544
www.aten.be E-mail: [email protected]
18/F, Tower A, Horizon International Tower,
No.6, Zhichun Road,
Haidian District, Beijing, China 100088
Phone: +86-10-5255-0110 Fax: +86-10-8296-1318
www.aten.com.cn E-mail: [email protected]
Taiwan Subsidiary :
U.K. Subsidiary :
Atech Peripherals, Inc.
ATEN U.K. Limited
229 Berwick Avenue, Slough, SL1 4QT, U.K.
Phone: +44-1753-539-121 Fax: +44-1753-215-253
www.aten.co.uk E-mail: [email protected]
6F., No.133, Sec. 2, Datong Rd., Sijhih District.,
New Taipei City 221, Taiwan
Phone: +886-2-8692-6969 Fax: +886-2-8692-6926
www.aten.com.tw E-mail: [email protected]
Security
Three-level password security
IP/MAC Filter for enhanced security protection
• Strong security features include strong password protection
and advanced encryption technologies – 128 bit SSL
• Remote authentication support: RADIUS, TACACS+, LDAP,
LDAPS and Active Directory
•
eco Sensors software has been developed to work with NRGence™ power distribution units (PDUs) to effectively increase the efficiency
of data center power usage. With the use of dynamic Rack Cooling Index (RCI) and Return Temperature Index (RTI) by zone, eco
Sensors software, in conjunction with sensor-enabled eco PDUs, gives you the means to assess, diagnose and estimate how much
energy you can save. Following the suggestions generated by the sensor-enabled system allows you to optimize energy usage to save
energy without harming your IT equipment’s reliability.
Model
PE98224B
PE98224G
PE98324B
PE98324G
# of Bank x Nominal
Output Power
20A, 346 – 415V
3 x 20A
NEMA L22-20P 3LNG Plug 200 – 240V
16A, 346 – 415V IEC309
3 x 16A
3PNPE Plug
200 – 240V
30A, 346 – 415V
6 x 16A
NEMA L22-30P 3LNG Plug 200 – 240V
32A, 346 – 415V IEC309
6 x 16A
3PNPE Plug
200 – 240V
Nominal Input Power
* Ready for compliance.
# of Outlet Socket x
Type
3 x IEC 320 C19 +
21 x IEC 320 C13
3 x IEC 320 C19 +
21 x IEC 320 C13
6 x IEC 320 C19 +
18 x IEC 320 C13
6 x IEC 320 C19 +
18 x IEC 320 C13
2012
2013
Automatic discovery of all PE devices within the same intranet
Remote real-time power measurement and monitoring
• PDU level current / voltage / power dissipation / power consumption
• Outlet ON / OFF / Recycle status
• Remote real-time power outlet management*
• Power outlet ON / OFF / Cycle switching by outlet
• User-defined outlet level delays for sequential power up
• Current / Voltage / Power Dissipation / Power Consumption threshold level setting
• User access assignment for every outlet
• Name assignment to individual outlets
• Remote real-time environment sensor monitoring
• Temperature / Temperature + Humidity reading / Temperature + Differential Pressure
• Temperature and Humidity threshold level setting
• Plotting/Monitoring of all PE devices
• Add data center server racks
• Add PE devices for each server rack
• Manage device/device outlet status for each plot
• Offers essential data center indices including RCI( Rack Cooling Index ), RTI ( Return Temperature Index ),
RHI ( Rack Humidity Index ), RPI ( Rack Pressure Index ), RAI ( Rack Airflow Index )
• Power analysis report for optimizing data center energy management – including power usage, power load,
power cost, CO2 cost, power capacity and trend
• Exceed threshold alert through SMTP and System log
• 10240 line event log
• System log provision
• Two-level password security
•
•
* Not all functions are supported by all NRGence™ PDU. Please see www.aten.com for more details.
•
Setup
Temperature Sensor
Normal
1
Unreachable
2
3
Warning
4
5
15
20
6
Critical
7
8
9
1
5
10
Differential
Pressure
Sensor
A
1
5
10
25
Internet/
LAN
IT Office
China Subsidiary :
ATEN China Co., Ltd.
Power status measurement at PDU and outlet levels
• LED indicators for current, voltage, power dissipation,
temperature, and humidity at the PDU and outlet levels
• Current, voltage, power dissipation, and energy consumption
displayed in a browser based UI for monitoring at the outlet,
group, PDU, and daisy-chain levels
• Alert threshold notification for selected events (On, Off, Recycle,
Failure, etc.), via audio alarm and blinking LEDs (locally), SMTP,
SNMP trap notification, and digital output
• Environment monitoring – supports external temperature /
temperature & humidity sensors for rack temperature and
humidity monitoring
• Current, voltage, power dissipation, energy consumption,
temperature, and humidity threshold level setting
• Auto-Ping pings a device to determine its status, if the ping
test fails after a set amount of time- it automatically takes
an action assigned
• Current and voltage threshold setting
• Naming support for outlets and outlet groups
• User outlet access assignment on an outlet-by-outlet basis
• Event logging and syslog support
• Integration with ALTUSEN CC2000 Management software
and KVM devices
• Supports Management Information Base (MIB) files for
SNMP
• API for 3rd party software centralized control integration
• Upgradeable firmware – daisy chained stations receive the
upgrade via the daisy chain bus
• Multilanguage support
Switching
Capability
Per Outlet
Regulatory Approval
Per Outlet
FCC, TUV-CB*, TUV-UL*,
TUV-PSE*
Per Outlet
Per Outlet
Per Outlet
Per Outlet
Per Outlet
The specification and pictures are subject to change without notice.
Per Outlet
Report Title: Sales Department IT Power Analysis
Daily Report: 2011/1/1 – 2011/5/5 by Bill Li
IT Office
Metering
Capability
IT Power Load Chart
IT Power Usage Chart
kWH
kWH
- Sales 3
6
6
4
4
- Sales 2
2
Sales
2
- Sales 1
1/1 2/2 3/3 4/4 5/5
1/1 2/2 3/3 4/4 5/5
IT Inventory List in Report
No.
eco PDU Sensor Probes
Server Storage
Name Peak Watts
Peak
CO2e/Hrs
Yearly Power Cost
Yearly CO2e Cost
Location
01
Web Server
3
1.8 kg
1200
600
L25
02
Log Server
6
3.6 kg
3600
1800
L27
*
CE, TUV-CB
FCC, TUV-CB*
TUV-UL*, TUV-PSE*
CE
TUV-CB*
Hardware Requirement
System Parameter
Operating System
Windows XP / Windows Server 2003 and later
Max PDU number
CPU
2.0 GHz Dual Core
Data Center Layout
1000
45x30
Display
Larger than 1024x768
Max Rack Number
500
Memory
2GB
Max Zone Number
20
Disk
300GB
Power Report Data
3 years
Network
10/100/1000 Mbp Ethernet
Real Time Dashboard Data
1 hours
®
© Copyright 2012 ATEN International Co., Ltd.
ATEN and the ATEN logo are trademarks of ATEN International Co., Ltd. All rights reserved. All other trademarks are the property of their respective owners. Printed 02/2012 V1.0
NRGence Catalog_cs3-2.indd 5-8
2012/4/17 11:29:58 AM
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement